Text

TURKEY POINT PLANT UNITS 3 AND 4 SEMIANNUAL RADIOACTIVE EFFLUENT RELEASE REPORT JANUARY 1992 THROUGH JUNE 1992 SUBMITTED BY NUCLEAR CHEMISTRY DEPARTMENT TURKEY POINT PLANT FLORIDA POWER AND LIGHT COMPANY J.

E. Ber Radiochemis R.

N. Steinke Chemistry Supervisor V.

ami sk Oper t'ons Mana er L.

W.

ce Plant General Manager

'9209090173 92082l PDR.

ADOCK 05000250 R

PDR

1

INDEX 1.0 Regulatory Limits 1.1 Liquid Effluents 1.2 Gaseous Effluents 2.0 Maximum Permissible Concentration 3.0 Average Energy 4.0 Measurements and Approximation of Total Radioactivity 4.1 Liquid Effluents Discussion a.

Unit 3 Liquid Effluents Summation b.

Unit 4 Liquid Effluents Summation 4.2 Gaseous Effluents Discussion a.

Unit 3 Gaseous Effluents Summation b.

Unit 4 Gaseous Effluents Summation 4.3 Estimate of Error 5.0 Batch Releases 5.1 Liquid 5.2 Gaseous 6.0 Unplanned Releases 7.0 8.0 Reactor Coolant Activity Site Radiation Dose 9.0 Offsite Dose Calculation Manual Revisions 10.0 Solid Waste and Irradiated Fuel Shipments 11.0 Process Control Program Revisions

I 4(

A

FLORIDA POWER AND LIGHT COMPANY TURKEY POINT UNITS 3 AND 4 EFFLUENT AND WASTE DISPOSAL SEMIANNUAL REPORT SUPPLEMENTAL INFORMATION JANUARY 1992 THROUGH JUNE 1992 1.0 REGULATORY LIMITS 1.1 Li uid Effluents a)

The concentration of radioactive material released in liquid effluents to unrestricted areas shall not exceed the concentration specified in 10CFR20 Appendix B,

Table II, Column 2 for radionuclides other than dissolved or entrained noble gases.

For dissolved or entrained noble

gases, the concentration shall not exceed 2.0 E-04 microcuries per milliliter.

b)

, The dose or dose commitment per reactor to a member of the public from any radioactive materials in liquid effluent released to unrestricted areas shall be limited as follows:

During any calendar

quarter, to less than or equal to 1.5 mrem to the total body and to less than or equal to 5 mrem to any organ.

During any calendar

year, to less than or equal to 3

mrem to the total body and less than or equal to 10 mrem to any organ.

1.2 Gaseous Effluents a)

The dose rate due to radioactive materials released in gaseous effluents from the site to areas at and beyond the site boundary shall be limited to the following:

Less than or equal to 500 mrem/'year to the total body and less than or equal to 3000 mrem/year to the skin due to noble gases.

Less than or equal to 1500 mrem/year to any organ due to I-131, I-133, tritium and for all radioactive materials in particulate form with half-lives greater than 8 days.

1

Ji I

b)

The air dose per reactor to areas at and beyond the site boundary due to noble gases released in gaseous effluents shall be limited:

During any calendar

quarter, to less than or equal to 5 mrad for gamma radiation and less than or equal to 10 mrad for beta radiation.

During any calendar

year, to less than or equal to 10 mrad for gamma radiation and less than or equal to 20 mrad for beta radiation.

c)

The dose per reactor to a member of the public, due to I-131, I-133, tritium and to particulates with half-lives greater than 8

days in airborne effluents released to areas at and beyond the site boundary shall not exceed 7.5 mrem to any organ during any calendar quarter and shall not exceed 15 mrem to any organ during any calendar year.

2.0 MAXIMUM PERMISSIBLE CONCENTRATIONS Water:

As per 10CFR20, Appendix B, Table II, Column 2, for entrained or dissolved noble gases as described in 1.1.A of this report.

Air:

Release concentrations are limited to dose rate limits described in 1.2.A.

3.0 AVERAGE ENERGY The average energy of fission and activation gases in effluents is not applicable.

I 4.0 MEASUREMENTS AND APPROXIMATIONS OF TOTAL RADIOACTIVITY All liquid and airborne discharges to the environment during this period were analyzed in accordance with Technical Specification requirements.

The minimum frequency of analysis as required by Regulatory Guide 1.21 was met or exceeded.

When

alpha, tritium and named nuclides are shown as curies on the following tables, this should be interpreted as "no activity was detected on the samples using the Plant Technical Specification analyses techniques to achieve required Lower Level of Detection (LLD) sensitivity for radioactive effluents".

'1

4.1 Li uid Effluents Aliquots of representative pre-release

samples, from the waste disposal
system, were isotopically analyzed for gamma emitting isotopes on a multichannel analyzer.

Frequent periodic sampling and analysis were used to conservatively determine if any radioactivity was being released via the steam generator blowdown system and the storm drain system.

Monthly and quarterly composite samples for the waste disposal system were prepared to give proportional weight to each liquid release made during the designated period of accumulation.

The monthly composite was analyzed for tritium and gross alpha radioactivity.

Tritium was determined by use of liquid scintillation techniques and gross alpha radioactivity was determined by use of a

solid state scintillation system.

The quarterly composite was analyzed for Sr-89, Sr-90 and Fe-55 by chemical separation.

.All radioactivity concentrations determined from analysis of a pre-release composite were multiplied by the total represented volume of the liquid waste released to determine the total quantity of each isotope and of gross alpha activity released during the compositing period.

Aliquots of representative pre-release samples from the waste disposal system were analyzed on a

per release basis for dissolved fission and activation gases by use of gamma spectrum analysis.

The resulting isotope concentrations were multiplied by the total volume released in order to estimate the total dissolved gases released.

The liquid waste treatment system is shared by both units at the site and generally all liquid releases are allocated on a 50/50 basis to each unit.

4.2 Gaseous Effluents Airborne releases to the atmosphere occurred from:

release of gas decay

tanks, the instrument bleedline, containment purges, and releases incidental to operation of the plant.

The techniques employed in determining the radioactivity in airborne releases are:

a)

Gamma spectrum analysis for fission and activation

gases, b)

Removal of particulate material by filtration and subsequent

-gamma spectrum

analysis, Sr-89, Sr-90 determination and gross alpha analysis, c)

Absorption of halogen radionuclides on a charcoal filter and subsequent gamma spectrum analysis, and d)

Analysis of water vapor in a gas sample for tritium using liquid scintillation techniques.

All gas releases from the plant which were not accounted for by the above methods were conservatively estimated as curies of Ze-133 by use of the SPTNG-4 radiation monitor and the plant ven't process monitor recorder chart and the current calibration curve for the monitor.

Portions of the gas waste treatment system are shared by both units and generally all gas releases from the shared system are allocated on a 50/50 basis to each unit.

Neteorological data for the period January 1992 through December

1992, in the form of Joint Frequency Distribution Tables is maintained on-site.

4.3 Estimate of Errors a)

Sampling Error The error associated with volume measurement

devices, flow measuring
devices, etc.,

based on calibration data and design tolerances has been conservatively estimated to be collectively less than

+ 10%.

b)

Analytical Error Our quarterly Q.C.

cross-check program involves counting unknown samples provided by an independent external lab.

The errors associated with our analysis of these unknown samples, and reported to us by the independent

lab, were used as the basis for deriving the following analytical error terms.

NUCLIDE TYPE AVERAGE ERROR MAXIMUM ERROR Liquid Gaseous

+2 '

+2.5

+14

+4 5.0 BATCH RELEASES 5.1 Liciuid Unit 3

Unit 4

a)

Number of releases, 1.05E+02 1.05E+02 b)

'Total time period of batch

releases, minutes 8.17E+03 8.17E+03 c)

Maximum time period for a batch release, minutes 1.55E+02 1.55E+02 d)

Average time period for a batch release, minutes 7.78E+01 7.78E+01 e)

Minimum time period for a batch release, minutes 3.00E+01 3.00E+01 f )

Average stream flow during period of release of effluent into a flowing stream, LPM 5.72E+06 5.72E+06 5.2 Gaseous Unit 3

Unit 4

a)

Number of batch releases 9.00E+00 9.00E+00 b)

Total time period of batch

releases, minutes 5.24E+02 5.24E+02 c)

Maximum time period for a batch release, minutes 2.40E+02 2.40E+02 d)

Average time period for a batch release, minutes 5.82E+01 5.82E+01 e)

Minimum time period for a batch release, minutes 1.50E+01 1.50E+01

6 0

UNPLANNED RELEASES 6.1

~iciuid Unit 3

Unit 4

a)

Number of releases b)

Total activity released, curies 6.2 Gaseous a)

Number of releases b)

Total activity released, curies 6.3 See Attachment 2, if applicable, for:

a)

A description of the event and equipment involved.

b)

Cause(s) for the unplanned event.

7.0'EACTOR COOLANT ACTIVITY 7.1 Unit 3

Reactor coolant activity limits of 100/E-bar and 1.0 microCurie per gram Dose Equivalent I-131 were not exceeded.

7.2 Unit 4

Reactor coolant activity limits of 100/E-bar and 1.0 microCurie per

'gram Dose Equivalent I-131 were not exceeded.

8.0 SITE RADIATION DOSE The assessment of radiation dose from radioactive effluents to the general public due to their activities inside the site boundary is performed as part of the end of year radioactive effluents report.

I 7a

9.0 OFFSITE DOSE CALCULATION MANUAL REVISIONS I

There were no ODCM revisions during this reporting period.

10.0 SOLID WASTE AND IRRADIATED FUEL SHIPMENTS No irradiated fuel shipments were made from the site.

Common solid waste from Turkey Point Units 3

and 4

were shipped jointly. A summation of these shipments is given in Table 6 of this report.

11.0 PROCESS CONTROL PROGRAM REVISIONS Changes to the Process Control Program are summarized in Attachment l.

f

~SF

TURKEY POINT PLANT SEMIANNUAL REPORT January 1992 THROUGH JUNE 1992 UNIT 3 TABLE 1 LI UID EFFLUENTS

SUMMARY

A.

FISSION AND ACTIVATION PRODUCTS Units Quarter 1

Quarter 2

1. Total Release(not including tritium, gasosg alpha
2. Average diluted concentration during period C1 6 '6 E-02 8.11 E-02 yCi/ml 3.28 E-09,.

3.00 E-09 B.

TRITIUM

1. Total Release 5.36 E+01 7.70 E+01
2. Average diluted concentration during period yCi/ml 2.72 E-06 2.85 E-06 C.

DISSOLVED AND ENTRAINED GASES

1. Total Release Ci 5.52 E-03 9.17 E-03
2. Average diluted concentration during period VCi/ml 2

8p E

1 p 3.40 E-10 D.

GROSS ALPHA RADIOACTIVITY

1. Total Release Ci E.

LI UID VOLUMES 1.

Batch waste

released, prior to dilution liters 8.75 E+05 1.09 E+06 2.

continuous waste

released, prior to dilution liters
3. Dilution water used during period liters 1.97 E+10 2.70 E+10

'0 I

l

~

TURKEY POINT PLANT SEMIANNUAL REPORT JANUARY 1992 THROUGH JUNE 1992 UNIT 3 TABLE 2 LI UID EFFLUENTS

SUMMARY

Nuclides Released Units Continuous Mode Batch Mode Quarter 1

Quarter 2

Quarter 1

Quarter 2

Cr-51 Mn-54 Fe-55 Co-57 Ci Ci Ci Ci 1.92 E-03

5. 21 E-02 2.25 E-03
6. 11 E-02 Co-58 Fe-59 Co-60 Zn-65 Sr-89 Sr-90 Nb-95 Zr-97 Mo-99 A -110 Sb-124 Sb-125 I-131 I-133 Ci Ci Ci Ci Ci Ci Ci Ci Ci Ci Ci 4.13 E-04 1.48 E 05 5.57 E-03
5. 19 E-05 2.55 E-05 5.40 E-04 3.27 E-,05 3.53 E-03 6.50 E

5 7.70 E-03 3.36 E-6 1.46 E-05 8.55 E-06

6. 12 E-04 4.56 E-04 1.79 E-04 7.35 E-06 Cs-134 Cs-137 La-140 W-187 Total for period Ci Ci Ci Ci Ci 7.84 E-04 3.11 E-03 6.46 E-02 9.23 E-04 3.96 E-03 1.52 E-04 6.55 E-05
8. 11 E-02

0 1

),I p

w s

SEMIANNUAL REPORT JANUARY 1992 THROUGH JUNE 1992 UNIT 3 TABLE 2 (continued)

LI UID EFFLUENTS

SUMMARY

LIQUID DISSOLVED GAS Nuclides Released Units Continuous Mode Batch Mode Ar-41 Kr-85m Xe-131m Xe-133 Xe-133m Xe-135

. Xe-135m Total for Period Ci Ci Ci Ci Ci Ci Ci Quarter 1

Quarter 2

Quarter 1

5.52 E-03 5.52 E-03 Quarter 2

7.39 E-06 2.52 E-06 3.95 E-05

9. 11 E-03 1.34 E-05 9.17 E-03 10

1I

TURKEY POINT PLANT SEMIANNUAL REPORT JANUARY 1992 THROUGH JUNE 1992 UNIT 3 TABLE 3 GASEOUS EFFLUENTS

SUMMARY

A.

FISSION AND ACTIVATION PRODUCTS

1. Total Release Ci Quarter 1

Quarter 2

1. 39 E+01
1. 10 E+01
2. Average Release Rate for Period yCi/sec 1.76 E+00 1.40 E+00 B.

IODINES

1. Total Iodine-131
2. Average Release Rate for Period Ci yCi/sec
2. 16 E-05 2.74 E-06 3.77 E-05 4.79 E-06 C.

PARTICULATES

1. Particulates Tl/2 8 days
2. Average Release Rate for Period
3. Gross Alpha Radioactivity Ci yCi/sec Ci D.

TRITIUM

1. Total Release
2. Average Release Rate for Period Ci yCi/sec

T

SEMIANNUAL REPORT JANUARY 1992 THROUGH JUNE 1992 UNIT 3 TABLE 4 GASEOUS EFFLUENTS

SUMMARY

A.

FISSION GASES Nuclides Released Units Continuous Mode Batch Mode Quarter 1

Quarter 2

Quarter 1

Quarter 2

Ar-41 I< -85m Kr-88 Xe-131m Xe-133 Xe-133m Xe-135 Xe-135m Total for period Ci Ci Ci Ci Ci Ci Ci Ci Ci 8.69 E+00 1.25 E+00 9.94 E+00 6.61 E+00

4. 37 E-01 7.05 E+00 6.95 E-02 3.82 E+00 2.83 E-02 9.05 E-03 3.93 E+00 4.50 E-05 1.01 E-04 1.30 E-04
7. 13 E-02 3.89 E+00
6. 15 E-03 1.63 E-02 3.98 E+00 B.

IODINES Nuclides Released Units Continuous Mode Quarter 1

Quarter 2

I-131 I-133 I-135 Total for period Ci Ci Ci

2. 16 E-05 8.35 E-06 7.30 E-06 3.73 E-05 3.77 E-05 2.23 E-05 6.00 E-05 C.

PARTICULATES Nuclides Released Units Continuous Mode Quarter 1

Quarter 2

Co-60 Cs-137 Total for period Ci Ci Ci 12

g

~

t f

I

Total for Period SEMIANNUAL REPORT JANUARY 1992 THROUGH JUNE 1992 UNIT 4 TABLE 1 LI UID EFFLUENTS

SUMMARY

A.

FISSION AND ACTIVATION PRODUCTS Units Quarter 1

Quarter 2

1. Total Release(not including tritium, gases, alpha Ci 6.46 E-02
8. 11 E-02
2. Average diluted concentration during period yCi/ml 3.28 E-09 3.00 E-09 B.

TRITIUM

1. Total Release
2. Average diluted concentration during period Ci 5.36 E+01 7.70 E+01 yCi/ml 2.72 E-06 2.85 E-06 C.

DISSOLVED AND ENTRAINED GASES

1. Total Release
2. Average diluted concentration during period Ci yCi/ml 5.52 E-03
2. 80 E-10 9 '7 E-03
3. 40 E-10 D.

GROSS ALPHA RADIOACTIVITY

1. Total Release Ci E.

LI UID VOLUMES 1

~ Batch waste

released, prior to dilution liters 8.75 E+05 1.09 E+06 2.

Continuous waste

released, prior to dilution liters
3. Dilution water used during period liters
1. 97 E+10 2 '0 E+10 13

I

~0) lt A

Vy 4"

SEMIANNUAL REPORT JANUARY 1992 THROUGH JUNE 1992 UNIT 4 TABLE 2 LI UID EFFLUENTS

SUMMARY

Nuclides Released Units Continuous Mode Batch Mode Quarter 1

Quarter 2

Quarter 1

Quarter 2

Cr-51 Mn-54 Fe-55 Co-57 Co-58 Fe-59 Co-60 Zn-65 Sr-89 Sr-90 Nb-95 Zr-97 Mo-99 A -110 Sb-124 Sb-125 I-131 Ci Ci Ci Ci Ci Ci Ci Ci Ci Ci Ci Ci Ci Ci 1.92 E-03 5 ~ 21 E-02 4.13 E-04 1.48 E-05 5.57 E-03

5. 19 E-05 2.55 E-05 5.40 E-04 3.27 E-05 2.25 E-03 6.11 E-02 3.53 E-03 6.50 E-5 7.70 E-03 3.36 E-6 1.46 E-05 8.55 E-06 6.12 E-04 4.56 E-04 1.79 E-04 I-133 7.35 E-06 Cs-134 Cs-137 La-140 W-187 Total for period Ci Ci Ci Ci 7.84 E-04 3.11 E-03 6.46 E-02 9.23 E-04 3.96 E-03 1.52 E-04 6.55 E-05 8 '1 E-02 14

t a

SEMIANNUAL REPORT JANUARY 1992 THROUGH JUNE 1992 UNIT 4 TABLE 2 (continued)

LI UID EFFLUENTS

SUMMARY

LIQUID DISSOLVED GAS Nuclides Released Units Continuous Mode Batch Mode Ar-41 Kr-85m Xe-131m Xe-133 Xe-133m Xe-135 Xe-135m Total for Period Ci Ci Ci Ci Ci Ci Ci Ci Quarter 1

Quarter 2

Quarter 1

5 52 E

03 5.52 E-03 Quarter 2

7.39 E-06 2.52 E-06 3.95 E-05

9. 11 E-03 1.34 E-05
9. 17 E-03 15

SEMIANNUAL REPORT JANUARY 1992 THROUGH JUNE 1992 UNIT 4 TABLE 3 GASEOUS EFFLUENTS

SUMMARY

A.

FISSION AND ACTIVATION PRODUCTS Quarter 1

quarter 2

1. Total Release Ci 1.62 E+01 9.84 E+00
2. Average Release Rate for Period yCi/sec 2.07 E+00 1.25 E+00 B.

IODINES

1. Total Iodine-131
2. Average Release Rate for Period Ci yCi/sec
2. 16 E-05 2.74 E-06 3.77 E-05 4.79 E-06 C.

PARTICULATES

1. Particulates Tl/2 8 days
2. Average Release Rate for Period
3. Gross Alpha Radioactivity Ci yCi/sec Ci D.

TRITIUM

1. Total Release
2. Average Release Rate for Period Ci yCi/sec 16

\\

I E

I

SEMIANNUAL REPORT JANUARY 1992 THROUGH JUNE 1992 UNIT 4 TABLE 4 GASEOUS EFFLUENTS

SUMMARY

A.

FISSION GASES Nuclides Released Units Continuous Mode Batch Mode Quarter 1

Quarter 2

Quarter 1

Quarter 2

Ar-41 Kr-85m Kr-87 Xe-131m Xe-133 Xe-133m Xe-135 Xe-135m Total for period Ci Ci Ci Ci Ci Ci Ci Ci Ci 8.69 E+00 1 '4 E+00 9.93 E+00 6.61 E+00 4.37 E-01 7.05 E+00

8. 19 E-02 6 95 E

02 6

09 E+00 2.83 E-02 3.67 E-02 6.31 E+00 4.50 E

05 1

~ 01 E-04 1.30 E-04 7.13 E-02 2.70 E+00 6.15 E-03 1.42 E-02 2.80 E+00 B.

IODINES Nuclides Released Units Continuous Mode Quarter 1

Quarter 2

I-131 I-133 I-135 Total for period Ci Ci Ci 2.16 E-05 8.35 E-06 7.30 E-06 3.73 E-05 3.77 E-05 2 '3 E-05 6.00 E-05 C.

PARTICULATES Nuclides Released Units Continuous Mode Quarter 1

Quarter 2

Co-60 Ci Cs-137 Total for period Ci 17

~

~

4 4

FLORIDA POWER AND LIGHT COMPANY TURKEY POINT PLANT SEMIANNUAL REPORT JANUARY 1992 THROUGH JUNE 1992 UNITS 3 AND 4 TABLE 6 SOLID WASTE AND IRRADIATED FUEL SHIPMENTS A.

'SOLID WASTE SHIPPED OFFSITE FOR BURIAL OR DISPOSAL 1.

TYPE OF WASTE UNITS 6 MONTH PERIOD

~oERR a.

Spent resin, filters m

sludge, evaporator bottoms Ci (Note 1) 1.25 E1 4.25 E-1 20 b.

Dry Compressible waste (Note 2) c.

Irradiated components Control rods, etc.

d.

Other non-compressible Waste (Note 3) mCi m

Ci m'i 9.98 E1 5.49 E-1 0.00 EO 0.00 EO 4.06 EO 2.56 E-1 20 20 2.

ESTIMATE OF MAJOR NUCLIDE COMPOSITION BY TYPE OF WASTE a 0 Cs-137 Co-60 Cs-134 Ni-63 Fe-55 Sb-125 Mn-54 UNITS VALUE 52 19 9

9 8

2 1

b.

Fe-55 Co-60 Ni-63 Co-58 Cs-137 Sb-125 45 33 16 3

2 1

c ~

18

h

FLORIDA POWER AND LIGHT COMPANY TURKEY POINT PLANT SEMIANNUAL REPORT JANUARY 1992 THROUGH JUNE 1992 UNITS 3 AND 4 TABLE 6 UNITS VALUE d.

Fe-55 Co-60 Ni-63 Cs-137 Co-58 Cs-134 Cr-51 Nb-95 Sb-125 37 31 15 9

2 2

2 1

1 3.

SOLID WASTE DISPOSITION NUMBER OF SHIPMENTS 23 (Note 4) 1 MODE OF TRANSPORT Sole use truck Sole use truck DESTINATZON Oak Ridge, TN

Barnwell, SC B.

IRRADIATED FUEL SHIPMENTS None 19

FLORIDA POWER 8 LIGHT COMPANY TURKEY POINT PLANT SEMIANNUAL REPORT JANUARY 1992 THROUGH JUNE 1992 UNITS 3 8 4 TABLE 6 SOLID WASTE SUPPLEMENT Total Waste Voiyne Classification Ft (HOTE 5)

(NOTE 6)

Total Principal Curie Radionuclides Ouantity (NOTE 7)

(NOTE 8)

Type of R.G.

1.21 Type of Solidification Waste Category Container or Absorbent Agent Class A

, 442.1 0.425 Cs-137 Dewatered Resin Iae

>Type A, LSA Cask H/A Class A

3523.8 0.549 None Compactable Waste 1b.

Strong Tight N/A Class A

143.3 0.256 None Non-Compactable 1d.

Waste Strong Tight N/A 20

~'Q

FLORIDA POWER AND LIGHT COMPANY TURKEY POINT PLANT SEMIANNUAL REPORT JANUARY 1992 THROUGH JUNE 1992 UNITS 3 AND 4 TABLE 6 SOL1D WASTE AND IRRADIATED FUEL SHIPMENTS A0 SOLID WASTE SHIPMENT OFFSITE FOR BURIAL OR DISPOSAL Note 1:

Spent

resin, filters,
sludge, and evaporator bottoms volume indicates volume shipped directly to burial site or shipped to burial site following reduction by a waste processing facility.

Volume shipped to the waste processing facility was 27.6 m~

Note 2:

Note 3:

Dry compressible waste volume indicates volume shipped to burial site following reduction by a waste processing facility.

Volume shipped to the waste processing facility was 1449.8 m~

Other noncompressible waste indicates volume shipped to a

waste processing facility for decontamination and disposal.

Volume shipped to the processing facility was 114.7 m

Note 4:

Material consigned reduction remaining processor transported to Oak

Ridge, Tennessee, was to licensed processing facilities for volume and decontamination activities.

The material, after processing was transported by the to Barnwell, South Carolina, for burial.

Note 5:

The total curie quantity and radionuclide composition of solid waste shipped from the Turkey Point Plant Units 3

and 4 are determined using a combination of qualitative and quantitive techniques.

The Turkey Point Plant follows the guidelines in the Low Level Waste Licensing Branch Technical Position on Radioactive Waste Classification (5/ll/83) for these determinations.

The most frequently used techniques for determining the total activity in a package are the dose to curie method and inference from specific activity and mass or activity concentration and volume.

Activation analysis may be applied when it is appiopriate.

The total activity determination by any of these methods is considered to be an estimate.

21

4 44 4'

FLORIDA POWER AND LIGHT COMPANY TURKEY P01NT PLANT SEMIANNUAL REPORT JANUARY 1992 THROUGH JUNE 1992 UNITS 3 AND 4 TABLE 6 The composition of radionuclides in the waste is determined by both on-site analysis for principle gamma emitters and periodic off-site analyses for difficultto measure isotopes.

The on-site analyses are performed either on a batch basis or on a routine basis using representative samples appropriate for the waste type.

Off-site analyses are used to establish scaling factors or other estimates for difficult to measure isotopes.

Principle radionuclide refers to those'adionuclides contained in the waste in concentrations greater than 0.01'imes the concentration of the nuclide listed in Table 1 or 0.01 times the smallest concentration of the nuclide listed in Table 2 of 10 CFR 61.

Type of waste is specified as described in NUREG 0782, Draft Environment Impact Statement on 10 CFR 61 "Licensing Requirements for Land. Disposal of Radioactive Waste".

Type of container refers to the transport package.

22

'I I

~

g

~gf

%i

FLORIDA POWER AND LIGHT COMPANY TURKEY POINT PLANT SEMIANNUAL REPORT JANUARY 1992 THROUGH JUNE 1992 UNITS 3 AND 4 ATTACHMENT 1

SUMMARY

OF CHANGES TO THE PROCESS CONTROL PROGRAM Pacific Nuclear, Inc.,

Waste Services Group Procedure PT-51-WS, Solidification Process Control Procedure, Revision 10, May 21,

1992, was approved for use at Turkey Point Nuclear Plant during this reporting period.

This vendor process control program, together with the supporting Topical Report, satisfies the requirements for solidification in Technical Specification 3/4.11.3, and provides assurance that the waste form produced conforms to the requirements of 10CFR61 and the disposal site licenses.

23

n 0

0 P

tq l,