Fracture Toughness of Steam Generator & Reactor Coolant Pump Supports,Donald C. Cook Units 1 & 2, Technical Evaluation Rept
ML17326A751
Person / Time
Site: Cook  American Electric Power icon.png
Issue date: 09/30/1980
From: Allten A, Dorschu K, Stilwell T
FRANKLIN INSTITUTE
To: Fair J
Office of Nuclear Reactor Regulation
Shared Package
ML17326A752 List:
References
CON-NRC-03-79-118, CON-NRC-3-79-118 TER-C5257-167, TER-C55257-167-168, NUDOCS 8010080419
Download: ML17326A751 (18)


Text

TECHNICAL.EVALUATIO'N REP'ORT'R'ACTURE TOUG HNESS'OF STEAM G ENERATOR AND REA'CTOR COO'LANT PUMP SUPPORTS INDIANA R. l'lICHIGAN POWER'ONPANY DONALD C,- COOK NUCLEAR POWER PLANT UNITS j AND 2,

'RCDOCKETNO.

50-315 and. 50-316

NRCTACNO.

08479 and 08486 NRCCONTRACTNO. NRC43-'79-TTS FRC,PROJECT C5257 FRCTASK 167 and 168 Prepared by Franklin Research Center The, Parkway at Twentieth Street Philadelphia; PA 19103 Authors:

T.C.8til~ell, A.G.Allten, K.E.Dorschu, P.N.Noell.

FRC Group Leader:

T.C.Stilwell Prepared for Nuclear Regulatory Commisslon-Washington, D.C. 20555 Lead NRC Engineer:

J.R.Fair September, 1980 This report'was prepared as. an account of work sponsored by an agency of the United States Government. Neither the United States Government nor any agency thereof, or any of their employees, makes any warranty, expressed, or implied, or assumes any legal liabilityor responsibility'for any third party'.s use, or the results of such; use, of any information, apparatus, product or process disclosed In this report, or represents that Its use by such third party wouldnot infringe prlvatelyownedrights.

801008o4 9

IjIj Franklin Research center A Division of The Franklin institute The BenjarrMn frenkhnParinvey, Phire.,PL 19103{215) 44$ 1000

TECHNlCAL EVALUATlONREPORT FRACTURE TOUGHNESS QF STEAM GENERATOR AND REACTOR COOLANTPUMP SUPPORTS INDIANA 5 NICHIGAN POWER COMPANY.

DONALD C.

COOK NUCLEAR'POWER PLANT UNITS j. AND 2 NRCDOCKETNO.

50-315 and 50-316 NRCTACNO.

08479 and 08486 NRC CONTRACT NO. NRC43-79-tT8 FRC PROJECT C5257 FRCTASK 167 and 168 Prepared by Franklin Research Center The Parkway at Twentieth Street Philadelphia, PA 19103 Authors:

T.C.Stilwel', A.G.Allten, K.E.Dorschu, P.N. Noell FRC Grou'p Leader:

T.C. Srilwell Prepared for Nuclear Regulatory Commission Washington, D.C, 20555 Lead NRC Engineer:

J.R.Fair September 1980 This report was prepared as an account of work sponsored by an agency of the United States Government. Neither the United States Government nor any agency thereof, or any of their employees, makes any warranty, expressed or Implied, or assumes any legal liabilityor responsibility for any third party's use, or the results of such

use, of any information, apparatus, product or process disclosed in this report, or represents that its use by such third party would not Infringe privately owned rights.

Ffl Franklin Research Center A Division of The Franklin institute The seniamin Frankhn 1'aria ey. Pate.. Pa. 19103 (215) ms.

1 coo

TER-C5257-167/168 CONTENTS Seccice Tie le

~Pa e

1

SUMMARY

2 INTRODUCTION 3

BACKGROUND

~

2 4

CRITERIA APPLIED IN THE EVALUATION.

4 4.1 Fracture-Toughness Grouping of Materials Used in Support Construction 4.1.1 Criterion.

4.1.2 Interpretation.

4.2 Plant Grouping for Fracture-Toughness Ranking of S/G and RCP Support Structures 4

5 5

4.2.1 Criterion 4e2.2 Interpretation.

4.3 Criteria for Fracture-Toughness Adequacy of S/G and RCP Supports 4.3.1 NDT Criteria for Screening.

4.3.2 Interpretation.

4.3.3 Alternative Criteria e

5 TECHNICAL EVALUATION

~

5

~

5

~

5

~

5 6

6

~

7 5.1 Review Procedure and Implementation of NRC Criteria 7

5.2 Review Findings 10 5.2.1 Use of Group I Materials in Applications Important to Structural Integrity of Supports 5.2.2 Thick Section Use of Group II Materials in Applications Important to Structural Integrity.

5.2.3 Thin Section Use of Group II Materials in Applications Important To Structural Integrity.

10 10 10 Ill) Franklin Research Center A Drerrron ofThe FreN@n fnreure

TER-C5257-167/168 5.2e4 5.2.5 Use of Materials Classified Group NUREG 0577, Upon Condition.

Use of Materials Classified, Group NUREG 0577, Outright 5.2.6 Issues Not Completely Resolved.

6 CONCLUSIONS II by IIIby 11 11 ll Number TABLE Title

~Pa e

5.1 COMPONENT SUPPORT

SUMMARY

e 8

00 Franklin Research Center A DeviskNt cl The Ftbnkltt InttiNtte

TER-C5257-167/168 1.

SUMMARY

Information concerning aspects of the fracture-toughness design of the steam generator (S/G) and reactor coolant pump (RCP) supports for the Donald C. Cook Nuclear Power Plant Units 1 and 2 was submitted to the Acting Director of the Office of Nuclear Regulation by the Indiana and Michigan Power Company (IMPC) by letter dated Nov. 23, 1977.

This information was reviewed at the Franklin Research Center (FRC) and evaluated in accordance with the criteria of the Nuclear Regulatory Commission (NRC) as set forth in NUREG 0577-Draft (henceforth referred to simply as NUREG 0577).

The information had previously been reviewed as part of the preparation of NUREG 0577 and D. C. Cook Units 1 and 2 had been assigned a Group III (rela-tively best) plant ranking for fracture toughness of S/G and RCP supports.

This ranking was regarded as tentative.

Subsequently, the NRC requested PRC to conduct an independent review prior to finalizing the ranking.

PRC's review was confined to fracture-'toughness issues in supports above the embedment.

The review was conducted in accordance with NRC criteria and to a procedure standardized for the several licensees whose support designs were reviewed at FRC.

As a resu1t of its review, FRC confirmed that the Group III plant ranking assigned to Donald C. Cook Nuclear Power Plants Units 1 and 2 for fracture toughness of S/G and RCP supports is justifiable.

2.

INTRODUCTION This report provides a technical evaluation of information supplied by IMPC with its letter of Nov. 23, 1977, to Mr. Edson G. Case, Acting Director Office of Nuclear Regulation.

The information concerns the fracture-toughness design of supports for the S/Gs and RCPs for D. C. Cook Units 1 and 2.

The objective of the evaluation is to rank the design for fracture-toughness integrity on a relative scale in accordance with the grouping scheme and criteria established in NUREG 0577.

Illlll Fran!din Research Center Allnskn ofThe Frankfn Insolate

TER-C5257-167/168 3 ~

BACKGROUND During the course of the NRC licensing review for two pressurized water reactors (PWR), North Anna Units 1 and 2, questions were raised regarding the fracture-toughness adequacy of certain members of the S/G and RCP supports.

The potential for lamellar tearing in some support members was also questioned.

The staff's concern in the North Anna licensing process was that perhaps not enough attention had been given to the selection of materials for, and fabrication of, the S/G and RCP supports.

Fracture toughness of a material is a measure of its capability to absorb energy without failure or damage.

Generally, a material is considered "tough" when, under 'stated conditions of stress and temperature, the material can withstand loading to its design limit in the presence of flaws.

Toughness also implies that, under certain conditions, the material has. the capability to arrest the growth of a flaw.

A lack of adequate toughness (accompanied by the combination of low operating temperature, presence of flaws, and nonredun-dancy of critical support members). could result in failure of the support structure under postulated accident conditions, specifically a loss-of-coolant accident (LOCA) and safe shutdown earthquake (SSE).

To address fracture-toughness concerns at the North Anna facility, the licensee undertook tests not originally specifi.ed and not included in the relevant ASTM specifications.

These tests indicated that material used in certain support members had relatively poor fracture toughness at 80'F metal temperature.

In this case the licensee agreed to raise (by ancillary electrical heat) the temperature of the S/G support beams in question to a minimum of 225'F every time, throughout the life of the plant, that the reactor coolant system (RCS) is pressurized above 1,000 psig.

The NRC staff found this to be an acceptable resolution.

Because similar materials and designs were used in other plants and be-cause similar problems were therefore possible, this matter was incorporated into the NRC Program for Resolution of Generic Issues as "Generic Technical 00 Franklin Research Center Aolvtsen or The Franklin Insist@

TER-C5257-167/168 Activity A12 Potential for Low Fracture Toughness and Lamellar Tearing on PWR Steam Generator and Reactor Coolant Pump Supports."

Since the original licensing action (North Anna Units 1 and

2) involved only the S/G and RCP supports of PWRs, the staff's initial efforts were di-rected toward examination of the corresponding supports at other PWR facili-ties.
However, the staff has kept in mind the possibility of expanding its review to include other support structures in PWR plants and support struc-tures in boiling water reactor (BWR) plants.

The integrity of support embedments was not questi.oned during the North Anna licensing action; consequently, emphasis was placed on resolving the most immediate generic issue whether or not problems similar to those uncovered at North Anna exist at other facilities. It was the staff's judgment that inclusion of an evaluation of support embedments in the initial review would require detailed, plant"specific investigations that were beyond the scope of the preliminary, overall generic review.

Such considerations were deemed more suited to a subsequent phase when more detailed investigations of individual plants might be undertaken.

Requests for information were sent to licensees in late 1977; responses to these requests were received during 1978.

Sandia Laboratories in Albuquerque, New Mexico, was retained to assist the staff in the revie~ and analysis of the information received from licensees and applicants.

Based on an analysis 'of the information, the technical stud-ies performed by Sandia Laboratories, and review of the issues by the NRC staff, the NRC developed an NRC staff technical posit:ion on these

issues, which is presented in NUREG 0577, "Potential for Low Fracture Toughness and Lamellar Tearing on PWR Steam Generator and Reactor Coolant Pump Supports."

In addition, NUREG 0577 establishes criteria for evaluation of the fracture-toughness adequacy of S/G and RCP supports.

NUREG 0577 also applies certain of these criteria to the support structures of a number of PWR plants to achieve plant groupings according to the relative fracture-toughness inte-grity of these supports.

lJllll FranMin Research Center A0!nsen cr The Franklin Inseam

TER-C5257-167/168 The plant ratings 'are:

~

Group I (lowest)

~

Group II (intermediate)

~

Group IIX (highest)

During the generic study, a number of PWR plants were reviewed for the fracture-toughness adequacy of their RCP and S/G designs, As a result of these

reviews, each plant was assigned a tentative plant ranking of either Group I, II, or III.

Several Plants, D. C. Cook Units 1 and 2 among them, were tentatively ranked Group IXI.

In the appendix to NUREG 0577 prepared by Sandia Labora-

tories, who initially established the rankings which subsequently received NRC staff endorsement, the significance of the Group XII ranking is described as:

"considered to be as good as careful, reasonable engineering practice can produce."

However, before finalizing the tentative Group III rankings, the NRC reque'sted FRC to conduct an independent review of the Group IXI plants (in conjunction with similar FRC task assignments to review the fracture-toughness adequacy of corresponding supports in certain other plants) and to prepare a

Technical Evaluation Report for each plant, presenting the review findings.

The technical evaluation reported herein applies the criteria of NUREG 0577 to the S/G and RCP supports for D. C. Cook Units 1 and 2 to provide an assessment of the fracture-toughness adequacy of these supports leading to a plant ranking.

4.

CRITERIA APPLIED IN THE EVALUATION 4.1 FRACTURE-TOUGHNESS GROUPING OF MATERIALS USED IN SUPPORT CONSTRUCTION 4.1.1 Criterion Table 4.6, Material Groups, of Appendix C to NUREG 0577 groups materials according to their relative fracture toughness as:

~

Group I (poorest)

~

Group II (intermediate)

~

Group III (best)

I FranMin Research Center ADhisen or The FnuU4n Inst+(e

TER-C5257-167/168 4.1.2 Interpretation If no supplementary requirements were called out in the material specifi-cation aimed at procuring a product with fracture-toughness properties supe-rior to those routinely supplied under the material specification, then the material was grouped in accordance with TabLe 4.6.

If additional requirements aimed at procuring a product with superior fracture-toughness properties were specified, consideration was given to cred-iting this specific material order with an improved material-group rating.

4.2 PLANT GROUPING FOR FRACTURE-TOUGHNESS RANKING OF S/G AND RCP SUPPORT STRUCTURES 4.2.1 Criterion Plants are classified on the basis of the construction materials used in the supports after giving consideration to the importance of their location and function within the structure, and their consequent importance to support-structure integrity.

(Refer to pages 5 and 6 of NUREG 0577, Part I.)

4.2.2 Interpretation Plants were assigned a plant-group ranking identical to the material-group ranking of the least fracture<<tough material used in the construction, pro-vided this usage is important to support integrity.

4.3 CRITERIA FOR FRACTURE-TOUGHNESS ADEQUACY OF S/G AND RCP SUPPORTS It is the clear intent of NUREG 0577 that licensees demonstrate the fracture-toughness adequacy of the'/G and RCP supports or that they take appropriate corrective measures to assure their fracture-toughness integrity.

NUREG 0577 provides guidance for such demonstrations

~

4.3.1 NDT Criteria for Screening 30'F

+

< Tsupports('F>

60 F

l Ill) Franklin Research Center h Dion or %be Franklin Inseam

TER-C5257-167/168 where:

~

NDT is the mean nil ductility transition temperature appro-priate to the material as given by Table 4.4 of Appendix C

to NUREG 0577 '

~

cr xs the standard deviation for the data used to determine NDT as listed in Table 4.4.

~

Tsupports is the lowest metal temperature that the support member will ever experience throughout the plant life when the plant is in an operational state.

In the absence of

measured, plant-specific datap Tsupports is taken as 75'F.

~

The temperature term, 30'F or 60'F, is an allowance for sec-tion size (30'F for thin sections and 60'F for thick,sec<<

tions).

4.3.2 Interpretation If evidence is furnished by the licensee proving that other values of NDT, a, or T are actually valid for the S/G or RCP supports and materi-als in the licensee's plant, such data may be used. If acceptable alternative evidence is not available, the above-stipulated values should be used.

4.3.3 Alternative Criteria NUREG 0577 also recognized that fracture-toughness integrity is a complex matter involving a number of interrelated

factors, most of which are plant specific.

Consequently, demonstration of compliance with the screening crite-ria is but one means of providing satisfactory assurance of fracture-toughness adequacy.

NUREG 0577 not only recognizes that other means of shoving compliance with the intent of NUREG 0577 are possible, but also offers extensive guidance re-lating to several approaches by which such a demonstration may be achieved.

Because of the plant-specific character that such demonstrations must take, NUREG 0577 does not restrict the licensees to any single approach but, instead, encourages each licensee to review the fracture-toughness adequacy of his S/G and RCP supports and submit evidence of his. findings.

l)ll Franklin Research Center AColon of The Ftsnl4n Ito5tuto

TER-C5257-167/168 5.

TECHNICAL EVALUATION The information furnished to the NRC regarding the fracture toughness of, and the potential for lamellar tearing in, S/G and RCP supports at D. C. Cook Units 1 and 2 was reviewed at FRC.

This information was supplied in response to the NRC staff's generic letter to PWR licensees concerning these issues.

A copy of the staff's request-for-information letter (in generic form) may be found in NUREG 0577, Appendix B.

Only fracture toughness issues wexe addxessed in the FRC review; the review procedure is described below.

5.1 REVIEW PROCEDURE AND IMPLEMENTATION OF NRC CRITERIA The drawings and information submitted were first examined to become I

familiar with the structural design, material selection, and construction practices.

Key items from this information were condensed to tabular form and are presented in Table 5.1.

In accordance with a review procedure standardized for the licensees whose plants were evaluated at FRC, the first step was to compile a list of materials used-in all members significant to the structural integx'ity of the S/G and RCP supports.

The listed materials were taken from those reported in the response to Item 1 of the NRC's request for information, supplemented by a survey of the support drawings for additional materials which might be indi-cated there.

To each of the materials so identified, two criteria tests were applied:

1.

The NDT criteria for screening (paragxaph 4.3.1 of this report).

2.

The material group ranking in accordance with the procedures of Section 4.1.

For plants which used them, materials with an assigned Group I or Group II fracture-toughness rating wex'e further categorized as thick or thin using the formula'shown on the following page to determine the section thickness above which brittle (plain strain) behavior may be anticipated under dynamic load.

I Franldin Research Center A Oh)sion d The Frank5n Insotu(c

TABLE 5 I COHPONENT SUPPORT

SUMMARY

PLANT:

Donald C. Cook I & 2 UTILITY Indiana

& Hichigan Pover HATEkIALS, NESS

)7estingbouse AE hnericsn Electric Pover Conpany SUPPORT SUPPLIER HAXIHUH ALLOUABLKDESICN STRESS TYPE HILL CERTS.

NEAT AVAILABLK

'TREATMENT NDK ON HATERIAL FRACTURE TOUGHNESS TEST NEHBRAME 6 BENDINC (NORMAL)

THROUGH THICKNESS Construction Hsterials:

A-618 Cr 2 A-36 h-588 Bolting Materials:

A-193 87 A19&Cr 7 AISI 4145

&&90 AISI 4340 Melding Haterials:

E60XX ~ E70XX 801&-Cl, 8018-CI, 8018-C 8016-C2. 8018"C2, 2"I/2X or 3-1/2Z Ni Content sub arc consunsbles Yes Yes h-36 to fino-grain practice Norns lised h-588 in Critical nenbere.

UT under veld areas Tbru~ickness Reduced brea Tests CVN for A-618, A 36, h-5SB (15 ft-lbs 830 F).

Also HAE and Meld Materials Nerval-Upset:

AISC Hanual hllovablas Energency:

0.9 8 Paul tetr Non-Linear Elastic-Plastic Analysis 0.65 Sy FABR1CATION MELDING PROCESS Hanual Hetal hrc Sub arc MELDING PROCEDURE AISC Code,Section IX Qualified Pro-cedures POST-MELDINC TREATHENT Stress Relief HETllODS USED TO PREVENT LAHELLAR TEARING AISC Code Joints NDE AND INSPECTIONS PERFORMED UT or RT vhere possible MP or LP U&SICH TYPE OF SUPPORT Pin~olunn COOK USED LOADINC CONDITIONS Homal:

DL + TL Upset:

DL s TL + OBE Energcncy:

DL + TL + DBE Faulted:

DL + TL + DBEs PR HINIHUH TEMPERATURE OF SUPPORT 60'F (hub(ant tenpersture near supporti)

TER-C5257-167/168 The critical thickness is given by:

"ID tc-2 ~ 5<

~

dyD where:

dyD is the dynamic yield strength of the steel.

KID is the nominal, minimum assured fracture toughness of the steel in accordance with values supplied by NUREG 0577.

0 tc is the critical thickness.

In members thicker than tc, brittle (i.e., plane strain) behavior may be expected.

A similar categorization for Group IIImaterials was not deemed necessary for purposes of the review because such materials are sanctioned for thick-section use by virtue of their group rating.

Structural drawings were then examined 'for:

1 ~

All structurally significant uses of Group I materials.

2 ~ All'tructurally signifi'cant uses of Group II materials in thick sections.

3.

Structurally significant applications of materials known to be sensitive to stress corrosion cracking or other special failure mechanisms which might make them prone to brittle behavior.

The circumstances associated with such usage were then examined.

Consider-ation was given to factors such as:

direction of loadings (always compressive or sometimes tensile), stress levels in the member as indicated in the licensee's

response, the presence of stress raisers in member geometries, re-dundancy of load paths, and the like.

Applications judged to be of problematic fracture toughness were identi.fied for more detailed evaluation at a future date.

In addition, information furnished on welding and on material specifica-tions was examined for its fracture-toughness implications by a welding engi-neer and a metallurgist, respectively. 00 Franklin Research Center A Dlvlslond The fsankSn hseute

TER-C5257-167/168 As a result of the review findings and in accordance with the criteria procedure described in Section 4.2 of this report:,

a tentative plant ranking for fracture-toughness adequacy of S/G and RCP supports was assigned.

5.2 REVIEW FINDINGS 5.2.1 Use of Group I Materials in Applications Important to Structural Integrity of Supports None found.

5.2.2 Thick Section Use of Group II Materials in Applications Important to Structural Integrity None. found.

5.2.3 Thin Section Use of Group II Materials in Applications Important To Structural Integrity ASTM A"618 steel is indicated on both S/G and RCP support drawings as the material for the main vertical columns.

These are constructed of 12 inch dia-meter, double-extra-strong pipe (i.e., seamless tube of 12 3/4 inch o.d.

and with 1 inch walls) ~

NUREG 0577 classifies ASTM A-618 as a Group II steel when furnished as formed and without additional specification requirements.

However, ASTM A-618 Grade 2 was specified for this tubing and Charpy V-notch testing was required.

Specification ASTM A-618 Grade 2 limits silcon content to a maximum of 0.30

percent, and to have only according to (which would requires addition of vanadium.

The actual steel used was analyzed 0.19 percent silicon (sufficient to completely deoxide the steel silicon-killed practice) and to contain 0.04 percent vanadium tend to promote a finer grain size)

~

The test report furnished in the information supplied to NRC by IMPC indicated that the steel possessed a Charpy V-notch impact energy of 24 ft-lbs at 30'F.

This value, if typical of all heats, qualifies this steel to be of adequate quality and toughness for 1 inch section usage.

ll00 Franklin Research Center AOvision ofThe Fcanklln Instate TER-C5257-167/168 5.2.4 Use of Materials Classified Group III by NUREG 0577, Upon Condition ASTM A-588 is the major component steel of both the S/G and RCP supports and was supplied as A-588, Grade A.

This steel is classified in NUREG,0577 as a Group II material in the as~oLLed or hot-worked condition.

However, in sections 1/2 inch thick and over, the steel was ordered normalized and Charpy V-notch impact tests were required.

The test data furnished for review indi-cate 'adequate toughness at 30 F in all thicknesses'n view of the additional requirements specified, the A-588 steel used in this application is deemed to be of sufficient quality and toughness to merit a Group IIImaterial rating.

5.2.5 Use of Materials Classified Group III by NUREG 0577, Outright All bolting and welding materials.

5.2.6 Issues Not Completely Resolved The text and materials table of the IMPC letter of response refer to use of ASTM A-36 steel as a material of construction for S/G and RCP supports in the Cook plants.

These also state that it was ordered to fine grain practice and required to be subjected to Charpy impact testing.

Vith such additional requirements the A-36 steel would be considered, under NUREG 0577 criteria, as sanctioned for general use in S/G and RCP supports.

However, FRC did not find it indicated as a material of construction on any of the drawings furnished for review nor could mill test or other material data for this steel be found among the extensive information supplied.

This question, although unresoLved, would not appear to affect the final classification of this plant.

6.

CONCLUSIONS The design and construction of supports for steam generators and reactor coolant pumps at Donald C. Cook Nuclear Power Plant Units 1 and 2 have been reviewed for fracture"toughness adequacy at the FRC.

Il( Franklin Research Center A Oinsion d The Fnu4din Immure

TER-C5257-167/168 Criteria for the suitability of materials and construction practices for S/G and RCP supports were provided by the NRC staff as published in NUREG 0577-Draft.

In the review, general criteria of NUREG 0577 were specifically applied to information furnished by Indiana and Michigan Power Company (IMPC) concern>>

ing the supports in D. C. Cook Units 1 and 2.

The review was restricted to supports (above the embedment) for steam generators and reactor coolant pumps.

Conclusions relating to them do not necessari.ly extend to the support design of other components.

In the case of D. C. Cook Units 1 and 2 FRC concludes that:

1.

Engineering measures taken in support design, material selection, material specification, material acceptance testing, fabrication

methods, and inspections provide reasonable evidence that the steam generator support structures possess adequate fracture toughness to meet NRC criteria for a Group III rating.

2.

Engineering measures taken in the design and construction of the reactor coolant pump supports provide similar evidence to qualify them for a Group III rating also.

3.

The Group III (relatively highest) plant rating for fracture-toughness adequacy of supports assigned to Donald C.Cook Nuclear Power Plant Units 1 and 2 in NUREG 0577-Draft is justifiable.

l)II Franklin Research Center AOMskn of The FiankSn Insane

~