Conformance to Generic Ltr 83-28,Item 2.1 (Part 1) Equipment Classification,Cook Units 1 & 2, Informal Rept
ML17334B110
Person / Time
Site: Cook  American Electric Power icon.png
Issue date: 03/31/1987
From: Haroldson R
EG&G IDAHO, INC., IDAHO NATIONAL ENGINEERING & ENVIRONMENTAL LABORATORY
To:
NRC
Shared Package
ML17334B103 List:
References
CON-FIN-D-6001 EGG-NTA-7609, EGG-NTA-7609-ERR, GL-83-28, TAC-52989, TAC-52990, NUDOCS 8706080242
Download: ML17334B110 (2)


Text

O ( Franklin Research Center A Division of The Franklin Institute July 27, 1983 U.S. Nuclear Regulatory Commission 8706080242 8703/ 9 Washington, D.C. 20555 PDR ADGCK 05000315 PDR Attention: Mr. M. Carrington (MS-540)

Project Officer

Reference:

FRC Project C5506 NRC Contract NRC-03-81-130 NRC TAC No. 42859, 42860 FRC Assignment No. 6 FRC Task No. 241

Title:

Technical Evaluation Report for Donald C. Cook Nuclear Plant Units 1 and 2, Masonry Wall Design

Dear Mr. Carrington:

Enclosed please find the Revised Technical Evaluation Report (TER) for Donald C. Cook Nuclear plant Units 1 and 2.

Appendix A (SGEB criteria) was inadvertently omitted earlier. It should also be noted that, based on the conversation between Drs. N. C. Chokshi and Vu Con, Response 9 of the report has been slightly rephrased.

If you have any questions about the report, please contact Dr. Vu Con (215/448-1162) .

'Submittal of this report completes FRC's effort on Task 241.

Very truly yours, S. Pandey project Manager j

Sp/VNC/ g Encl.

cc: D. Jeng (1 copy)

N. C. Chokshi (3 copies)

C. Trammell (1 copy) 20th & Race Streets, Philadelphia, Pa. 19103 (215) 448-1000 TWX-710 670 1889

-0 I II ~ ~

1

'I

~ I) 0 lf