05000335/LER-1980-070-03, /03L-0:on 801222,steam Generator Level Indication a Showed Incorrect Reading.Caused by Stuck Movement of Sigma Instruments Level Indicator Model 9222-00ED Serial 10214.Movement Exercised & Surveillance Test Repeated

From kanterella
(Redirected from ML17266A403)
Jump to navigation Jump to search
/03L-0:on 801222,steam Generator Level Indication a Showed Incorrect Reading.Caused by Stuck Movement of Sigma Instruments Level Indicator Model 9222-00ED Serial 10214.Movement Exercised & Surveillance Test Repeated
ML17266A403
Person / Time
Site: Saint Lucie 
Issue date: 01/21/1981
From: Pace P
FLORIDA POWER & LIGHT CO.
To:
NRC OFFICE OF INSPECTION & ENFORCEMENT (IE REGION II)
Shared Package
ML17209A660 List:
References
LER-80-070-03L, LER-80-70-3L, NUDOCS 8102250633
Download: ML17266A403 (1)


LER-1980-070, /03L-0:on 801222,steam Generator Level Indication a Showed Incorrect Reading.Caused by Stuck Movement of Sigma Instruments Level Indicator Model 9222-00ED Serial 10214.Movement Exercised & Surveillance Test Repeated
Event date:
Report date:
3351980070R03 - NRC Website

text

NRC FOAM SKS I7 77 I U. S. NUCI.KAR REGULATORY COMMISSION LICENSEE EVEII!TREQQRT

'CD I

LKIII I

I IQ I

I I

I I

I I I I

Ql I

I I

I IQ~I I

IQ UCKVSKE CQOE Ic

'5 SIC>>iNSC NUNS ER

=>>:8 UCSVSC TYPc 70 31 AT Ii 0

2

'O~Q I

I I 'O

>>QURcs I

30 d I QQCRETi 'VUMSKR 38 39 EVENTCATE 15

'EPORT OATS 30 VENT OESCRIPTION <<NO PROBAEI.E CONScCUENCES Qio urin 100% power operations, surveillance testing on the Remote Shutdown

~o>>

anel was bein erformed.

When 'A'team generator level indication

~as isolated in accordance with Operating Procedure

0030151, tHe 9

indication read 0% instead of 65% as it should'have.

Action was taken

~o 9

Iin accordance with T.S.3.3.3.5a and this channel was returned to service

~o 7

in seven hours.

This is the first LER 'of this type.

~oa 7

i 9

30

~O9 SYSTcM

CAUSE

CAUSE

COMP, VAUV4 C

OK COOK SUSC OE COMPONENT QQE SUSCQOK SUSCOCE DDS L IS LJS~i0 LDS LlO 9

'I0 II I'2 12 i

~

IS'9

~

~ 0 SEQUENTIAL CC~JRIIKVCK REPQAT SEVISIO I CEPQ T NO C

22 '2 Xd 21 2>>

<<9

<<0

~ I 32 ACTION SUTURE EFFECT SNUTCONCN ATTACIDMENT VPRO~

PRIME C MP.

CQMPCVKNT TAICKN ACTION C.'I P'<<UVT

<<AKTIDCO NOUAS ~22

>>USMITTEQ PCRM 548.

SVP43.IER MAVUPAC<<URSR L'DSLDS LDS C-'IS ~(

LDO ENDS MIS '>>i 24

<<5 2d 21

~ 40 4 I 42 44 41 CAUS'E OESCRIPTION ANO CORREC'i IVE ACTIONS Q27 o

This instrument, a Sigma Instruments level indicator Model 9222-OOED Serial 10214 had a stuck movement.

The movement was exercised and.it o crated ro erl when the surveillance was repeated.

The channel was then declared operable.

No further corrective action is planned.

7 i

9 PACIU ~ I ST<<ATUS 4<<)CYIKR QTIIER STATUS Q QDD L44~~'~

7 8

IO I2

'I>>

44 ACTIVITY CONTE."IT SEI.EAsKIT QP RELY>>K AMQUNTOPA~VITVQSS uz Q"

~zQS NA 9

IO ID 44 PERSONNEI, EXPOSURE>>

~i> ~ll

'Qs~ ~Z(DD NA 9

I I 12 IS PSERSCNNEI. IiWURDEZ METECQ CP CISCQVcBY

~SQ27 0

4>>

48 NA I.QCATIOVOF REI.SASK QS QISCCVKRV ESCRIPTIQN 2 erator

- Observation 9

7 i

~2 1

I I I'2 VCSS OP CR QAM*cc ~ Q PACIUTV QAS TiYPK QESCRIPTIQN u'QC 10 PVSI.IC'.V

SSUKO SKSCRIPTICN GS L N'0
0 NA'ME OF PRFPARcR NA NA P. L. Pace 30 NRC USc CNI V I I! IIIIIIII 38 99 30 (305) 552-3801 PDIONE:

SXOSS50(83.

3