05000335/LER-1979-025-03, /03L-0 on 790720:variable High Power Trip Setpoint in Core Protection Calculator Failed to Track Reactor Power. Caused by Power Supply in Core Protection Calculator Failing Due to Filter Capacitor Failure

From kanterella
(Redirected from ML17266A091)
Jump to navigation Jump to search
/03L-0 on 790720:variable High Power Trip Setpoint in Core Protection Calculator Failed to Track Reactor Power. Caused by Power Supply in Core Protection Calculator Failing Due to Filter Capacitor Failure
ML17266A091
Person / Time
Site: Saint Lucie 
Issue date: 08/17/1979
From: Schoppman M
FLORIDA POWER & LIGHT CO.
To:
NRC OFFICE OF INSPECTION & ENFORCEMENT (IE REGION II)
Shared Package
ML17207A322 List:
References
LER-79-025-03L, LER-79-25-3L, NUDOCS 7908300711
Download: ML17266A091 (1)


LER-1979-025, /03L-0 on 790720:variable High Power Trip Setpoint in Core Protection Calculator Failed to Track Reactor Power. Caused by Power Supply in Core Protection Calculator Failing Due to Filter Capacitor Failure
Event date:
Report date:
3351979025R03 - NRC Website

text

NRC PORM~

IT TTI LlCEblSEB EVENT REPORT U 5 HUCI SAR RSCU~TORY COhcAIISSION I

I I

lQI (PI.EAS1 9AINTOR TYP8 ALLRKCUIRSD INPORMATIONI

~OI Fl LIS L S ll i 2

0 Ol - 0 Ol Ol Ol 0 -

0 0

)

( 4ll 1

1 1

QA L;CSN54 TY>S 70

$1 ~7 u

,C CICSNu4 C004 I~Q.

LICSNSS 3lVAASSA 7C~

~O 7

"~ICD 50 0

03 352J~II

'7 2tl 7

9Q~II5 Itll7 9Q 40

~ I OOOCST95IUAISSA

$4 49 SVSNTOATS IA 7$

AS>OIITOATS

$0 8VSNT OSSCRIPTION ANOfRO8ASI.8 CONSSOUS5VCSS

~10 Ouring power reduction, the variable high power trip setpoint on channel "C" in the core protection calculator failed to track reactor power.

~03 Action in accordance with Technical Specification 3.3.1.1 was initiated.

A;0 5 volt power supply was repaired and the channel restored to operable condition within the time 'limit s ecified.

There was no adverse affect

'n'he plant.

Three channels remained operable and no additional action

~09 was required.

This was the first occurrence of this type.

~08 1

$0 SYSTSIA CAUSS CAV54 CCAI@.

vAUv4 COOS COOS SV5COOS CCAI>ONSNT COOS SVSMOS fVSCOOS tJ023S'~J>

LaJDJ ~9J I JO 227>

7 9

10 II 11 13 15 19 10 SSOVSNTIAV OCCVAASNCS AS>OAT ASVISION I >SINO SV4N'TYSAA AS>OATNO

" COOS TY>4

~

NO, Q>>

.4~AT ~7~ ~ ~I~

~~

~~

~L

~

~0 11 11 tA 14 '7 10 11 11 ACTION

>VTVAS Sf>SCD SNUTOOWN

'LXISDTJS "D~JO LIJ9J 0 '0"'037 "03JO "DJ315 "~VIE LLLD-4',ls CAUS8 OSSCRIPTION ANO CORRKCfIV6ACTIONS

~

The variable high power trip setpoint did not track the power level reduc-tion due to a failed power supply in the core protection calculator.

The ower suo 1

failed because of a failed filter capacitor.

The cause of. the capacitor failure is not known.

The most probable cause is normal end of life of an electronic component.

9fACIU ~ f, XTATVS

'\\ 7OINSA 07$14il STATUS Q

~s

~Q~

L005~tQ)9 NA 7

4 10, I'1 11 ACTIVITY CONTSNT IISlSA540 Of A4l SA54

~

ANOVNTOP ACTIVITYQ)S

~18

~Z Q))

~ZQ)$

NA I

5 9

10 lA

>SII50NNSI. 47I>OSVIISS.

7 ~03 0

Q33 ~lQTD NA 5

I I 11 11

>fi15ONNSI INIVRI45 3

~05 0

QDD NA NA 1CCATION Of RSI,SA54 Q)8 4ISTIICO 0>

OISCOVSBY 015COVSAY OSSCBI>TICN 32

~A Ql 0 erator Observation 30 7

3.9 11 11 10550> Cll 0*MACS.0 fAOUTYQ+3

~I9

~fQA2 7

4 1

10

>VSI.ICTY I55040 045CPI>T:ON~

LN IQ<4

'I 4

7

'.0'A7318 OP PRSPAR cR NA NA M. A. Schoppman 7908300 t t) 10 30 NRC USc ONI Y (305) 552-3802