ML17207A322

From kanterella
Jump to navigation Jump to search
Forwards LER 79-025/03L-0
Date released: 01/25/2018 Download: ML17207A322


LER 79-025/03L-0 on 790720:variable High Power Trip Setpoint in Core Protection Calculator Failed to Track Reactor Power. Caused by Power Supply in Core Protection Calculator Failing Due to Filter Capacitor Failure
ML17266A091
Person / Time
Site: Saint Lucie 
Issue date: 08/17/1979
From: Schoppman M
FLORIDA POWER & LIGHT CO.
To:
NRC OFFICE OF INSPECTION & ENFORCEMENT (IE REGION II)
References
Download: ML17266A091 (1)
Forwards LER 79-025/03L-0
ML17207A321
Person / Time
Site: Saint Lucie 
Issue date: 08/17/1979
From: Schmidt A
FLORIDA POWER & LIGHT CO.
To: OREILLY J P
NRC OFFICE OF INSPECTION & ENFORCEMENT (IE REGION II)
References
Download: ML17207A321 (1)