ML17229A724
ML17229A724 | |
Person / Time | |
---|---|
Site: | Saint Lucie ![]() |
Issue date: | 05/15/1998 |
From: | Rajiv Kundalkar FLORIDA POWER & LIGHT CO. |
To: | NRC OFFICE OF INFORMATION RESOURCES MANAGEMENT (IRM) |
References | |
L-98-132, TAC-MA0666, TAC-MA666, NUDOCS 9805200313 | |
Download: ML17229A724 (19) | |
Text
CATEGORY 1 REGULAT Y INFORMATION DISTRIBUTIO ~ SYSTEM (RIDS)
ACCESSION NBR:9805200313 DOC.DATE: 98/05/15 NOTARIZED: YES DOCKET I FACIL:50-389 St. Lucie Plant, Unit 2, Florida Power & Light Co. 05000389 AUTH.NAME .- AUTHOR AFFILIATION KUNDALKAR,R.S. Florida Power & Light Co.
RECIP.NAME RECIPIENT AFFILIATION Document Control Branch (Document Control Desk)
SUBJECT:
Forwards responses to 980408 RAI re proposed license amend for TS change on soluble boron credit at St Lucie,Unit 2.
DISTRIBUTION CODE: A001D COPIES RECEIVED:LTR ENCL SIZE:
TITLE: OR Submittal: General Distribution NOTES:
RECIPIENT COPIES RECIPIENT COPIES ID CODE/NAME LTTR ENCL ID CODE/NAME LTTR ENCL PD2-3 LA 1 1 PD2-3 PD 1 1 GLEAVES,W 1 1 0 INTERNAL: ACRS FILE CENTS 1 1 NRR/DE/ECGB/A 1 1 EMCB 1 1 NRR/DRCH/HICB 1 NRR/DSSA/SPLB 1 1 NRR/DSSA/SRXB 1 1 NUDOCS-ABSTRACT 1 1 OGC/HDS3 1 0 EXTERNAL: NOAC 1 1 NRC PDR 1 1 D
C U
E N
NOTE TO ALL "RIDS" RECIPIENTS:
PLEASE HELP US TO REDUCE WASTE. TO HAVE YOUR NAME OR ORGANIZATION REMOVED FROM DISTRIBUTION LISTS OR REDUCE THE NUMBER OF COPIES RECEIVED BY YOU OR YOUR ORGANIZATION, CONTACT THE DOCUMENT CONTROL DESK (DCD) ON EXTENSION 415-2083 TOTAL NUMBER OF COPIES REQUIRED: LTTR 14 ENCL 13
k P
Florida Power & Light Company, 6351 S. Ocean Drive, Jensen Beach, FL 34957 May 15, 1998 L-98-132 10 CFR 50.90 U. S. Nuclear Regulatory Commission Attn: Document Control Desk Washington, D. C. 20555 Re: St. Lucie Unit 2
'ocket No. 50-389 Proposed License Amendment: SFP Storage Capacity; Soluble Boron Credit AC No. MA0666 Res onse to Re uest for Additional Information Ref: (1) FPL Letter L-97-325, J. A. Stall to NRC (DCD): Proposed License Amendment, SFP Storage Capacity; Soluble Boron Credit; December 31, 1997.
(2) NRC Letter, W. C. Gleaves to T. F. Plunkett (FPL): REQUEST FOR ADDITIONAL INFORMATION-TECHNICAL SPECIFICATION CHANGE REQUEST FOR SOLUBLE BORON CREDIT-ST. LUCIE PLANT, UNIT 2 (TAC NO. MA0666); April 8, 1998.
Reference 1 is an application for license amendment from Florida Power and Light Company (FPL) which will modify Technical Specification 5.6.1 and associated Figure 5.6-1, and Technical Specification 5.6.3 to accommodate an increase in the allowed spent fuel pool storage capacity.
Reference 2 forwarded a request for additional information (RAI), which is identified as information needed by the NRC staff to complete its review of the amendment request. The questions and FPL's responses are contained in the Attachment to this letter.
Please contact us if there are any questions about this submittal.
Very truly yours, Rajiv S. Kundalkar Vice President Nuclear Engineering RSK/EJW/RLD Attachment cc: Regional Administrator, Region II, USNRC.
Senior Resident Inspector, USNRC, St. Lucie Plant.
Mr. W.A. Passetti, Florida Department of Health and Rehabilitative Services.
98052003i3 9805i5 PDR ADQCK 05000389 P PDR an FPL Group company
I
,\
St. Lucie Unit 2 L-98-132 Docket No. 50-389 Page 2 Proposed License Amendment: SFP Storage Capacity; Soluble Boron Credit AC No. MA0666: Res onse to Re uest for Additional Information STATE OF FLORIDA )
) ss.
COUNTY OF ST. LUCIE )
Rajiv S. Kundalkar being first duly sworn, deposes and says:
That he is Vice President, Nuclear Engineering, for the Nuclear Division of Florida Power 8 Light Company, the Licensee herein; That he has executed the foregoing document; that the statements made in this document are true and correct to the best of his knowledge, information and belief, and that he is authorized to execute the document on behalf of said Licensee.
Rajiv S. Kundalkar STATE OF FLORIDA COUNTYOF g. Zuci~
Sworn to and subscribed before me this <<day of by Rajiv S. Kundalkar, who is personally known to me.
Sign atur qg bfgry g orida EXPlRES: June 17, 2000 "Pp ~g" Bandedl1uu Nohuy Pub5c Undevnitore Name of Notary Public (Print, Type, or Stamp)
<<'P, l
yel
St. Lucie Unit 2 L-98-132 Docket No. 50-'389 Attachment Proposed License Amendment: SFP Storage Capacity; Soluble Boron Credit Page 1 of 12 AC No. MA0666: Res onse to Re uest for Additional Information 1.0 Introduction and Purpose On December 31, 1997, Florida Power and Light Company (FPL) submitted a proposed license amendment (PLA) to the NRC that would increase the licensed storage capacity of the St. Lucie Unit 2 spent fuel pool (Reference 1). The criticality analysis prepared in support of this submittal credited the negative reactivity associated with the presence of soluble boron in the spent fuel pool and the negative reactivity resulting from decay of fuel assembly actinides during long term post-irradiation storage. The PLA also addresses the likelihood of an inadvertent fuel pool dilution and the impact of the increased spent fuel pool heat load on the pool structure and the existing pool cooling system.
During their review of this PLA, the NRC staff has identified several questions for FPL which are documented in Reference 2.
2.0 Response to NRC Questions Each question is restated and is followed by FPL's prepared response. Input for responses to Questions 1, 2, 4, 8, 9, 10 and 11 was received from Asea Brown Boveri-Combustion Engineering (ABB-CE). Questions 1 and 2 refer to certain Tables and Figures contained in the criticality analysis (CENPD-387, submitted as Enclosure 1 to Reference 1).
2.1 To what fuel assembly configuration does Table 4 and 5 correspond?
FPL Res onse to Question 1:
The multiplication factors given in Tables 4 and 5 of the Criticality Safety Analysis (CENPD-387) were calculated for the entire fuel pool assuming it was loaded with 1360 fuel assemblies. The fuel assemblies stored in Region I rack modules are arranged as shown in Figure 9. The remaining fuel assemblies are stored in Region II rack modules as shown in Figure 10. The fuel pool and overall rack geometry, including the cuirently installed cell blocking devices, is shown in Figure 1 of CENPD-387.
2,2 Were the actual loading patterns shown in Figure 9 and Figure 10 mocked up in the analysis'PL Res onse to uestion 2:
Yes. The base pool multiplication factor was calculated for the entire pool, in which each subregion (or fuel assembly class) was represented by its equivalent fresh fuel enrichment. These equivalent enrichments are given in Figures 9 and 10.
St. Lucie Unit 2 L-98-132 Docket'o. 50-389 Attachment Proposed License Amendment: SFP Storage Capacity; Soluble Boron Credit Page 2 of 12 AC No. MA0666: Res onse to Re uest for Additional Information 2.3 What procedures are in place to assure that these loading patterns are not violated?
FPL Res onse to uestion 3:
2.3.1 Fresh Fuel Following its receipt and inspection, fresh fuel is stored in the new fuel storage racks. At some time subsequent to receipt but prior to the refueling evolution, fresh fuel is typically transferred into storage locations in Region I of the spent fuel racks. As stated in Technical Specification 5.6.1, Region I of the storage racks is designed to accommodate fresh fuel. Placement of new fuel in the spent fuel storage racks is controlled by Operating Procedure (OP) No. 1610020, ~Recet t and Handlin of New Fuel and CEAs and by Administrative Procedure (AP) No. 2-0010250, Guidelines for Use of the Unit 2 Hi h Densit S ent Fuel Racks. Section 8, Instructions," of OP-1610020, Revision 22, clearly states that new fuel may only be stored in Region I of the spent fuel pool.
Following approval of FPL's proposed license amendment and prior to placement of fresh fuel assemblies into the proposed spent fuel pool arrangement, these procedures will be modified as necessary to ensure that the Region I loading pattern is not violated.
2.3.2 Fuel discharged from the core is transferred to the spent fuel pool using the guidance specified in Pre-Operational Procedure (POP) 3200090, BefuelingMperation. Appendix E of this procedure contains a detailed list of the required fuel assembly movements which is updated and independently verified prior to use in each refueling campaign. The fuel assembly move list that makes-up this appendix describes the repositioning of each fuel assembly or assembly insert in detail: it specifies the sequential order of each move, the fuel assembly identifier, initial and final locations of the fuel assembly or assembly insert to be moved and the correct azimuthal orientation of the fuel assembly. A current copy of this procedure and the move list are required to be present at each fuel handling machine location during fuel movements.
During the refueling evolution, the parameters of each fuel assembly move are verified against the planned move sequence to ensure total agreement. All parties to the refueling evolution participate in this process. To document assembly moves as they actually occur, each move and the move characteristics are manually entered into a log for comparison to the move list discussed above.
2.3.3 As required by 10 CFR 70.51(d), a physical inventory of the spent fuel pool is conducted at least once per year and following the completion of refueling activities. AP- 0010439, Epical geMreas, provides detailed guidance on how to perform this inventory. Verification of fuel bundle and insert (CEA) serial numbers is required for all fuel pool locations to which special nuclear material has been added or removed. The results of this verification are compared to the approved fuel pool maps found in the Plant Physics Curve Book.
St. Lucie Unit 2 L-98-132 Docket No. 50-389 Attachment Proposed License Amendment: SFP Storage Capacity; Soluble Boron Credit Page 3 of 12 AC Ho. MA0666: Res onse to Re uest for Additional Information 2.3.4 Fuel Currentl in Stora e Although the current configuration of fuel assemblies stored in the Unit 2 spent fuel pool meets the reactivity requirements of the proposed license amendment, the currently stored fuel must be repositioned to comply with the requirements of the revised criticality analysis while accommodating the storage of additional fuel assemblies beyond the current limit of 1076. This fuel repositioning will not be performed during refueling operations but will utilize procedural controls equivalent to those in POP-3200090. As described above, an independent verification of fuel assembly locations in the storage racks will be performed following this fuel and insert repositioning. These repositioned permanently discharged fuel assemblies are unlikely to be further handled prior to initiation of fuel cask loading operations.
The design input upon which procedure step sequences are based will be provided by an engineering package. This engineering package will be prepared following approval of the license amendment and will include the conditions necessary to meet the requirements of the criticality, boron dilution, and fuel pool cooling analyses.
2,4 lf previously used control element assemblies (CEAs) are used for the inserted CEA cases, how is CEA depletion accounted for?
FPL Res onse to Question 4:
CEA depletion effects have not been included for the following reasons:
- a. St. Lucie Unit 2 o eratin histo is essentiall unrodded. Only full strength CEAs are considered in the criticality analysis to control the assembly reactivity in the spent fuel pool; these CEAs must have been part of a five finger regulating or shutdown bank, excluding the lead bank. The lead bank contains reduced strength CEAs which are not suitable to control the reactivity in the spent fuel pool Typically, all CEA banks are fully withdrawn
~
during steady-state operation, with the exception of a weak insertion programming sequence instituted to mitigate guide tube wear. This unrodded operation minimizes the boron depletion in the CEA fingers.
- b. The bottom ortion of the CEA fin er is com osed of Silver-Indium-Cadmium. The five finger full strength control rod design includes a non-depleting 12.5 inch Silver-Indium-Cadmium section at the bottom of each finger, plus two half-inch spacers and a 0.6 inch tip piece. The first depletable B4C pellet is located about 35 cm above the tip of the control rod.
At that elevation, the boron reaction rate is a few percent of what it would be at the tip of the CEA, had the CEA contained B4C over its entire length. Depletion effects 35 cm above the CEA tip are negligible.
- c. The CEA ti is in a Iow im ortance re ion. Should the spent fuel pool approach criticality, it will do so under a top peaked flux distribution, since the fissile content of the burned fuel assemblies is higher at the top of the fuel. The top peaked fission rate in the depleted fuel will also drive the fresh fuel axial flux distribution to a top peaked shape. This will reduce the importance of the CEA tip, and will minimize the impact of any potential CEA depletion.
St. Lucie Unit 2 L-98-132 Docket No. 50'-389 Attachment Proposed License Amendment: SFP Storage Capacity; Soluble Boron Credit Page 4 of 12 AC No. MA0666: Res onse to Re uest for Additional Information
- d. Durin the lifetime of a CEA the rod worth is measured at the be innin of each c cle and no de letion effects are discernible. CEA depletion is not modeled in rod worth physics predictions. The accuracy of these rod worth predictions is monitored during the startup testing program for each fuel cycle. After several cycles of irradiation, there is no indication that the CEA worth has been reduced by depletion effects.
2.5 How is inadvertent CEA removal from stored fuel assemblies precluded?
FPL Res onse to Question 5:
Manipulation of both fuel and CEAs in the spent fuel pool is performed using the spent fuel handling machine hoist. The grapple tool used to handle CEAs has a different design than the grapple tool used to handle fuel assemblies. As a result, a grapple change must be made following any fuel manipulation in order to initiate a CEA repositioning campaign. Additionally, neither fuel assemblies nor fuel assembly inserts stored in the spent fuel pool may be handled or repositioned except as described in specific procedural guidance.
As noted in the response to question 3 above, a physical inventory of the spent fuel pool is periodically performed as directed by AP-0010439. The locations of fuel assemblies containing CEAs and the CEA identifier are noted during this inventory. Upon determination that the as-found spent fuel pool configuration is, in fact, the correct configuration, this arrangement is documented in the plant physics curve book as the new required fuel pool storage arrangement. Following the completion of fuel handling evolutions and inventory veriTication the spent fuel handling machine is parked over the fuel transfer canal, configured for long term lay up and deenergized.
e 2.6 How is the presence of CEAs, if required, in stored, fuel assemblies assured?
FPL Res onse to Question 6:
The presence of CEAs in stored fuel assemblies where required is assured by the requirements of the fuel move list from POP-3200090, Refuelin 0 eration, Appendix E, and by additional guidance that will be added to AP-2-0010250, Guidelines for Use of the Unit 2 Hi h Densit S ent Fuel Racks.
The permissible pool storage locations for irradiated fuel given in Appendix E are developed using fuel assembly initial enrichment values and a conservative determination of the accumulated fuel assembly bumup. Required fuel pool storage location information is developed as a part of the reload design engineering package and is independently verified. The presence of a CEA in a fuel assembly can be visually confirmed at multiple points during fuel assembly handling.
Fresh fuel is typically received on-site and staged to the spent fuel pool prior to the commencement of refue)ing operations. Most fresh fuel assemblies initially placed in the fuel pool will not contain CEAs. As a result, these unrodded assemblies initially will be placed in alternating cell locations of rows where storage is permissible.
During refueling operations, fuel assemblies temporarily off-loaded from the core will be placed in a Region I storage location consistent with their bumup and initial enrichment. A number of these off-loaded fuel assemblies will contain full strength CEAs; during full core fuel off-loads future
St. Lucie Unit 2 L-98-132 Docket'o. 50-389 Attachment Proposed License Amendment: SFP Storage Capacity; Soluble Boron Credit Page 5 of 12 AC No. MA0666: Res onse to Re uest for Additional Information versions of Appendix E to POP-3200090, Refuelin 0 erations, will intersperse the most reactive of these assemblies with the fresh fuel discussed above.
2.7 Should the word "restrictive" in revised TS 5.6.1d be "reactive" ?
FPL Res onse to uestion 7:
Other than the required re-numbering of this item, no changes are proposed to Technical Specification 5.6.1d. As a result, the appropriate word in the fourth line of this specification is "reactive".
2.8 For which specific actinides and fission products is burnup credit given?
FPL Res onse to Question 8:
The fuel assembly depletion calculations were performed with the two-dimensional multi-group transport code DIT, using an 89-group ENDF/B-Vl based cross section library. The DIT cross section library includes 21 actinide and 116 fission product nuclides, which contribute to the reactivity loss with bumup. The depletion chains used to generate nuclide concentrations for the spent fuel pool criticality analysis are the same as those used in nuclear design, which have been benchmarked through core follow analysis. The lists of actinides and fission products are given in the following tables. Samarium and Promethium isotopes of mass number 149 are explicitly modeled with a yield due to direct fission (denoted by the "D" suffix in the table) and a yield due to production from other isotopic decay.
Actinides and Fission Products Included in DIT Depletions with ENDF/B-Vl Cross Sections Actinides 92-U -235 94-PU-242 92-U -236 95-AM-241 92-U -237 95-AM-242 92-U -238 95-AM-242M 93-NP-237 95-AM-243 93-NP-238 96-CM-242 93-NP-239 96-CM-243 94-PU-238 96-CM-244 94-PU-239 96-CM-245 94-P U-240 96-CM-246
St. Lucie Unit 2 L-98-132 Docket'o. 50-389 Attachment Proposed License Amendment: SFP Storage Capacity; Soluble Boron Credit Page 6 of 12 AC No. MA0666: Res onse to Re uest for Additional Information Fission Products 35-BR- 81 44-RU-105 53-I -129 59-PR-1 43 63-EU-151 36-KR- 83 44-RU-106 53-1 -131 60-ND-142 63-EU-153 36-KR- 85 45-RH-103 53-I -135 60-ND-143 63-EU-154 38-SR- 89 45-RH-105 54-XE-131 60-ND-144 63-EU-155 38-SR- 90 46-PD-104 54-XE-132 60-ND-145 63-EU-156 39-Y - 89 46-P D-105 54-XE-133 60-ND-146 63-EU-157 39-Y - 91 46-P D-106 54-XE-134 60-ND-147 64-GD-154 40-ZR- 91 46-P D-107 54-XE-135 60-ND-148 64-GD-155 40-ZR- 93 46-P D-108 54-XE-136 60-ND-150 64-GD-156 40-ZR- 95 47-AG-109 55-CS-133 61-PM-147 64-GD-157 40-ZR- 96 47-AG-110M 55-CS-134 61-PM-148 64-GD-158 41-NB- 95 47-AG-111 55-CS-135 61-PM-148M 65-TB-159 42-MO-95 48-CD-110 55-CS-136 61-PM-149D '5-TB-160 42-MO- 96 48-CD-111 55-CS-137 61-PM-149 65-TB-161 42-MO- 97 48-CD-113 56-BA-134 61-PM-151 66-DY-160 42-MO- 98 49-IN-115 56-BA-137 62-SM-147 66-DY-161 42-MO- 99 51-SB-121 56-BA-140 62-SM-148 66-DY-162 42-MO-100 51-SB-123 57-LA-139 62-SM-149 D 66-DY-163 43-TC- 99 51-SB-125 57-LA-140 62-SM-149 66-DY-164 44-RU-100 51-SB-127 58-CE-141 62-SM-150 67-HO-165 44-RU-101 52-TE-127M 58-CE-142 62-SM-151 44-RU-102 52-TE-129M 58-CE-143 62-SM-152 44-RU-103 52-TE-132 58-CE-144 62-SM-153 44-RU-104 53-I -127 59-PR-141 62-SM-154 2.9 What additional uncertainties are assumed when credit for actinide and fission product decay are calculated?
FPL Res onse to Question 9:
No additional uncertainties were considered for actinide and fission product decay. The decay calculations were performed with the DIT code, using the set of actinide and fission product nuclides described in the response to Question 8. The short lived nuclides such as l-131, Xe-131, Pm-149 and NP-239 were decayed for all pool criticality calculations. For long cooling periods, the decay of Pu-241 into Am-241 is by far the most important transition.
Because St. Lucie Unit 2 is operated with an unrodded core, exposures of discharged assemblies are characterized by nearly symmetric axial burnup distributions that have a slight
St. Lucie Unit 2 L-98-132 Docket No. 50-389 Attachment Proposed License Amendment: SFP Storage Capacity; Soluble Boron Credit Page 7 of 12 AC No. MA0666: Res onse to Re uest for Additional Information top peaked bias. As a result, there are minor differences between axially uniform isotopic distributions and the actual assembly nuclide distributions. A slightly top peaked Pu-241 distribution will decay into a slightly top peaked Am-241 distribution. This non-uniformity in isotopic distribution results in a small non-conservative reactivity effect relative to the uniform axial distributions that were assumed in decay calculations.
Conservate measures embedded in the model more than compensate for any postulated axial isotopic distribution effect. For instance, the assumption used in the depletion of a constant 1000 ppm soluble boron and 1200' fuel temperature results in a hardened spectrum which leads to an overprediction of the fissile content and to an overprediction of the reactivity in the spent fuel pool configuration. Typical reactivity effects after a 15 year cooling period are as follows:
Enrichment (w/o) Exposure Conservatism due Non-conservatism Net Conservatism
<IVIWD/T) to nominal ppm & due to axial Pu-Tfuel 241 redistribution at 15 years % delta-k
% delta-k
% delta-k 3.0 22,400 0.6 0.4 0.2 4.5 40,000 0.6 0.5 0.1 These results should not be extrapolated to higher bumup because the maximum exposure of 40,000 MWD/T considered above conservatively bounds the minimum burnup required in Region II after 15 years of cooling time.
2.10 How do the characteristics of the critical experiments used for benchmarking compare with those of the St. Lucie Unit 2 fuel and spent fuel storage racks?
The fuel used at St. Lucie Unit 2 is the 16 x 16 ABB-CE fuel assembly design for 136.7-inch active height cores. The fuel rods consist of sintered UO2 pellet columns encapsulated in zircaloy; the assumed UO2 maximum fuel enrichment is 4.5 wt% U-235 and 5.0 wt% for Gd-UO2 fuel. The fuel assembly storage rack modules are the Combustion Engineering, Inc.
monolithic design and employ 0.135-inch thick SS-304 box walls; in the Region I modules, a 0.188-inch thick SS-304 L-insert is employed in each storage cell.
Selected lattices from two experimental programs were employed in the benchmarking analyses: (1) the Babcock 5 Wilcox program "Critical Experiments Supporting Close'Proximity Water Storage of Power Reactor Fuel, Summary Report, BAW-1484-7:" M. N. Baldwin, et al.;
July, 1979, and (2) the Pacific Northwest Laboratory program "Criticality Experiments with Subcritical Clusters of 2.35 and 4.31 wt% U-Enriched UO2 Rods in Water with Steel Reflecting
St. Lucie Unit 2 L-98-132 Docket No. 50-389 Attachment Proposed License Amendment: SFP Storage Capacity; Soluble Boron Credit Page 8 of 12 AC No. MA0666: Res onse to Re uest for Additional Information Walls," S. R. Bierman and E. D. Clayton: Nuclear Technology, Volume 54, page 131; August, 1981 ~ More up-to-date information on material compositions for the latter experimental program was obtained from documentation in the International Handbook of Evaluated Criticality Safety Benchmark Experiments prepared by the Nuclear Energy Agency and the Organization for Economic Cooperation and Development.
The experiments from these two programs were selected for the benchmarking of the SCALE methodology employed in analyzing the St. Lucie Unit 2 fuel storage rack based on the following key parameters which span the variables of interest.
- 1) The fuel rods employed in the experiments contain sintered UO2 and employ low absorption clad tubes;
- 2) The enrichments of the fuel rods employed in the critical experiments are 2.549 wt%
for the B&W fuel and 4.306 wt% for the PNL fuel, thus providing a close approximation to the range of interest for the storage rack analyses;
- 3) The B&W experiments employ a 3 x 3 array of 14 x 14 fuel rod clusters and the PNL experiments employ a 2 x 2 array of rod clusters with typical rod cluster sizes of 9 x 12 or 11 x 14 rods;
- 4) Eight of the B&W experiments employ 0.188-inch thick SS-304 isolation sheets in the water channels separating the rod clusters in the 3 x 3 array and two of the PNL lattices employ either 0.191-inch or 0.119-inch thick SS-304 isolation sheets in the cross shaped channel separating the rod clusters in the 2 x 2 array;
- 5) The PNL experiments extrapolate to critical on number of fuel rods with non-borated moderator whereas the B&W experiments employ fixed numbers of fuel rods in each lattice and go critical on water height for a given soluble boron concentration.
Therefore, the geometry and composition of the critical experiments provides a good match to the St. Lucie Unit 2 spent fuel pool.
2.11 The usual allowance for possible uncertainties in the fuel depletion analysis is 0.01 delta-k at 30,000 MWD/MTU applied linearly (5% of the reactivity decrement to the burnup of interest). Justify your use of 0.005 delta-k.
FPL Res onse to uestion 11:
The reactivity of the spent fuel pool as a function of burnup depends on the input nuclide concentrations as a function of burnup and on the microscopic cross sections assigned to these nuclides. The evolution of the nuclide concentrations was calculated by the two-dimensional multi-group transport code DIT, with an 89 group cross section library based on ENDF/B-VI.
Benchmarking of the ROCS-DIT design codes using ENDF/B-Vl cross sections for several operating cycles demonstrated a smail reactivity bias as shown in Figure 1. The reactivity bias is defined as the calculated reactivity at the measured core critical conditions, as specified by
St. Lucie Unit 2 L-98-132 Docket No. 50-389 Attachment Proposed License Amendment: SFP Storage Capacity; Soluble Boron Credit Page 9 of 12 AC Ho. MA0666: Res onse to Re uest for Additional Information the core exposure, critical boron concentration, power level, inlet temperature and control rod insertion. This reactivity bias is bounded by the bias of 0.005 delta-k per 30,000 MWD/T applied to the St. Lucie Unit 2 spent fuel pool This lends confidence to the reactivity level and
~
to the nuclide concentrations generated for spent fuel pool criticality analyses.
Two conservatisms were also included in the nuclide concentration determination for the St.
Lucie Unit 2 spent fuel pool. The first conservatism lies in the soluble boron concentration used in the DIT depletions. The assembly DIT depletions were performed at a soluble boron concentration of 1000 ppm. The high boron concentration results in a hardened spectrum, magnifies the conversion ratio and results in an increased fissile content at discharge.
Therefore, the assembly reactivity will be conservatively overestimated when placed in the spent fuel pool.
The second conservatism lies in the fuel temperature used in the DIT depletion. A constant temperature of 1200' was assumed throughout the depletion, rather than the more realistic relationship where fuel temperature decreases with increasing bumup. The high fuel temperature increases the U-238 resonance absorption, increases the conversion ratio and magnifies the fissile content. From the above discussion, it can be concluded that the fissile content will contribute to a slight overprediction of the reactivity. A portion of these conservatisms have been used to address a reactivity effect associated with Pu-241 decay.
An additional component of the spent fuel pool reactivity lies in the cross sections used in KENO.
KENO uses a 44 group cross section library based on ENDF/B-V. A comparison of DIT and KENO reactivities for the same set of nuclide concentrations was performed for a pin cell and a whole assembly. The most straightforward comparison between the DIT and KENO cross section libraries is through a pin cell reactivity calculation. This comparison was done for both a fresh fuel pin enriched to 4.5 wt%, and a fuel pin having an initial enrichment of 4.5 wt% depleted to 40,000 MWD/T.
Using the same set of nuclide concentrations, the KENO pin cell shows a.reactivity gain over the DIT pin cell of 276 pcm by 40,000 MWD/T. The KENO whole assembly calculation includes a further conservatism by assuming that the pin bumup distribution is flat, i.e. there was no provision to account for the impact of the water holes on the bumup distribution. This assumption is conservative, because the fuel rods adjacent to the water holes exhibit a higher bumup and a lower k-infinity. These pins have a higher importance in the assembly because of the softer spectrum and higher flux induced by the large water holes. Therefore, an assembly modeled with a uniform bumup is more reactive than an assembly having a distributed burnup at 40,000 MWD/T.
The discussion provided above shows the conservatism of KENO relative to DIT. Having established the good reactivity performance of DIT as a function of burnup, one can conclude that KENO is conservative in its reactivity estimates for depleted fuel, and that the reactivity bias of 0.005 delta-k per 30,000 MWD/T is sufficient.
2.12 St. Lucie Unit 2 is requesting to take credit for soluble boron in the spent fuel pool (SFP) as a means to maintain ketf less than 0.95. Standard technical specifications (TS) for Combustion Engineering designed plants do not credit soluble boron, yet still
St. Lucie Unit 2 L-98-132 Docket No. 50-389 Attachment Proposed License Amendment: SFP Storage Capacity; Soluble Boron Credit Page 10 of 12 AC No. MA0666: Res onse to Re uest for Additional Information I
include a surveillance requirement to sample the SFP every 7 days. Please explain why the surveillance should not be included in St. Lucie's TSs.
FPL Res onse to Question 12:
FPL has reviewed the Standard Technical Specifications Limiting Condition for Operation (LCO) 3.7.17, Fuel Stora e Pool Boron Concentration, and its basis, which are provided in Volumes 1 and 3 of NUREG 1432. Based on our review of this LCO, 10 CFR 50.36, and Specification 5.6.1a. of St.
Lucie Unit 2 TS, FPL believes that Specification 5.6.1a. and the plant procedures which implement the minimum boron concentration requirement provide assurance that the effective neutron multiplication factor of the spent fuel pool will not exceed 0.95. The rationale for this conclusion is presented below.
10 CFR 50.36(c) defines Surveillance Requirements to be: requirements relating to test, calibration or inspection to assure that the necessary quality of systems and components is maintained, that facility operation will be within the safety limits, and that the limiting conditions for operation will be met.
FPL believes that the proposed limitations on fuel pool boron concentration do not meet the definition of a safety limit as given in 10 CFR 50.36(c)(1) because the fuel pool is not at risk to experience an uncontrolled release of radioactivity due to an unmonitored soluble boron concentration or with a boron concentration of 0 ppm. Postulated initiators of fission product release from the fuel pool typically involve cladding failure due to drop or impact.
10 CFR 50.36(c)(2) defines an LCO as the lowest functional capability or performance levels of equipment required for safe operation of the facility. Application of this definition to fuel pool soluble boron would result in a boron concentration value for surveillance purposes substantially less than the 1720 ppm value proposed by FPL. As noted in FPL's license submittal, a fuel pool boron concentration of as little as 520 ppm following any inadvertent dilution will still ensure kerf remains less than 0.95.
In addition to the lower boron value that would satisfy the requirements for a Limiting Condition for Operation, NUREG 1432 LCO 3.7.17 suffers from an additional defect when used in the context of fuel pool soluble boron credit: fuel pool boron concentration is only required to be greater than the specified value and the surveillance is only required to be performed during the period between initiation of fuel movement and the completion of a fuel pool verification or inventory. While the period of applicability is sufficient to ensure that the fuel pool contains no misloaded fuel assemblies, this LCO will not provide ongoing assurance that the Unit 2 fuel pool kerf is less than 0.95.
St. Lucie TS 5.6.1a. requires that the soluble boron concentration in the spent fuel pool be maintained greater than or equal to 1720 ppm and, unlike the Limiting Condition for Operation proposed by NUREG 1432, this requirement is applicable at all times. At St. Lucie, two procedures primarily implement the Specification 5.6.1a. boron requirement.
St. Lucie plant Chemistry Operating Procedure (COP) 05.04, Revision 1, Chemist De artment Surveillances and Parameters, Appendix B, "Schedule for Periodic Tesfs", requires that the boron concentration of the Unit 2 spent fuel pool shall be determined at least once per 7 days. Appendix D of this procedure, "Nuclear Chemisby Parameters", provides limits and the normal value range for
St. Lucie Unit 2 L-98-132 Docket No. 50-389 Attachment Proposed License Amendment: SFP Storage Capacity; Soluble Boron Credit Page 11 of 12 AC Ao. MAG666: Res onse to Re uest for Additional Information the boron concentration in the spent fuel pool and the refueling water tank (RWT). This procedure uses a limit value of 1720 ppm and gives a normal value range of between 1800 and 2050 ppm.
In addition to the requirements noted above, COP-05.03, Revision 2, Refuelin Shutdown/Startu Guidelines, provides guidance on sampling frequency for fuel pool boron during the different phases of Mode 6 operation. While in Mode 6 but prior to the initiation of fuel movement, boron concentration is sampled daily. During fuel movement and prior to the completion of core verification, fuel pool boron is sampled at least once per 12 hours1.388889e-4 days <br />0.00333 hours <br />1.984127e-5 weeks <br />4.566e-6 months <br />. Following core verification, boron concentration is sampled each day for the remainder of Mode 6 operation. FPL believes increased sampling frequencies are appropriate during Mode 6 operation because of the interconnection of makeup flow and purification paths between the refueling cavity, the fuel transfer canal, and the spent fuel pool.
To ensure that these boron sampling frequencies and the normal range values given above are not modified without an evaluation of the consequences of any change, a reference to FPL's proposed license amendment evaluation and, if appropriate, to the NRC-generated safety evaluation, will be added to each procedure discussed above following the approval of FPL's license amendment submittal.
For these reasons, FPL believes that including the NUREG 1432 surveillance in St. Lucie's TS is not
.L i i i ill i ..1. dh ii procedures ensure that the spent fuel pool boron concentration and the effective neutron i
p multiplication factors remain bounded by analysis assumptions.
3.0 Conclusions The responses to NRC-generated questions provided above render additional elaboration on areas addressed in the original PLA submittal prepared by FPL. Each of the responses support the conclusions of the PLA submittal and the no significant hazards determination prepared by FPL.
I
~
j
St. Lucie Unit 2 L-98-132 Docket No. 50-389 Attachment Proposed License Amendment: SFP Storage Capacity; Soluble Boron Credit Page 12 of 12 AC Ao. MAQ666: Res onse to Re uest for Additional Information Q) 0 O Cll CC) Cll Cll CJ CJ Cl Cl Ch 0 O 0 0m O 0 4 X CI Cl O
CCl P) 4 4
X 0
X 4 oo o O
0 0
o X O Cl Cl o X LL n X ILL Vl d)
X o
I-Ul O m
O X 0
CQ 0 0
0 O 0 o O O
0 X CCl 0 0 X CV CC 0
0.
X uj O
C5 I0 Cl X C 4 O
'a X 0
CS 0 O 0 Cl C5 o Cl O Cl 0
8 0
O 0 0
0 0 0 4
0 Cl O
CCl CCl O
(% sea W-pa/d) ssla Aqnpoeag