ML17194A390

From kanterella
Jump to navigation Jump to search
Forwards Evaluations of Util Safety Assessment Repts Re SEP Topics XV-7 & XV-15.Evaluations Will Be Basic Input to Integrated Assessment for Facility But May Be Revised If Facility Design Is Changed
ML17194A390
Person / Time
Site: Dresden Constellation icon.png
Issue date: 01/04/1982
From: Crutchfield D
Office of Nuclear Reactor Regulation
To: Del George L
COMMONWEALTH EDISON CO.
References
TASK-15-07, TASK-15-15, TASK-15-7, TASK-RR LSO5-82-01-004, LSO5-82-1-4, NUDOCS 8201070001
Download: ML17194A390 (15)


Text

r..._<!:

,, ~**,;, ~

Docket No. S0-237

~~

LS05-8£:- 01-004 Mr. L. Del George Ofrector of Nuclear Lfcens1ng Commonwealth Edfson Company Post Office Box 767 Chfcago, I111nof s 60690 *

Dear Mr. Del George:

~*

January 4, 1982

SUBJECT:

DRESDEN 2 *SEP TOPICS XV-7 AND XV-15 By 1 etter dated October 15, 1981, you subn1tted safety assessment reports for the above topfcs. The staff has reviewed these assessments and our conclusions ~re presented 1n the enclosed safety evaluation reports, which complete these topics for Dresden 2.

These evaluatfons will be: a basic fnput to the integrated assessment for your facility. The evaluations may be revised 1n the future if your facflfty design fs changed of ff NRC criteria relating to these topfcs are modified before the_ integrated asseSSJTlent 1s completed.*

Enclosures:

As stated cc w/enclosures:

See next page 8201070001 820104 PDR ADOCK 05000237 p

PD~

OFFICE ******* ~.~-~f.1.?t/.

EMcKenna :dp SURNAME *************************

12/ ::28 /81 DATE

  • NRC FORM 318 (10-80) NRCM 0240 Sincerely, Dennis M. Crutchfield, Chtef Operating Reactors Branch No. 5 Dfvtsion of Lfcensf ng OFFI IAL RECORD COPY USGP0:1981-335-960

Mr. L. DelGeorge cc Isham. Lincoln & Beale Counselors at Law One First National Plaza. 42nd Floor Chicago. Illinois 60603 Mr *. Ooug Scott Plant Superintendent Dresden Nuclear Power Station Rural Route #1 Morris. Illinois 60450 Natural Resources Defense Council 917 15th Street. N. W.

Washington. D. C.

20005 U. S. Nuclear Regulatory Conunission Resident Inspectors Office Dresden Station RR #1 Morris. Illinois 60450 Mary Jo Murray Assistant Attorney General Environmental Control Division 188 W. Randolph Street Suite 2315 Chicago. Illinois 60601 Morris Public Library 604 Liberty Street Morris. Illinois 60451 Chairman Board of Supervisors of Gruney County Gruney County Courthouse Morris. Illinois 60450 John F. Wolfe. Esquire 3409 Shepherd Street Chevy Chase. Maryland 20015 Dr. Linda w. Little 500 Hermitage Drive Raleigh. North Carolina 27612

'DRESDEN 2 Docket No. 50-237 Illinois Department of Nuclear Safety 1035 Outer Park Drive. 5th Floor Springfield, Illinois 62704 U. S. Environmental Protection Agency Federal Activities Branch Region V Office ATTN:

EIS COORDINATOR 230 South Dearborn Street

. Chicago. Illinois 60604 Dr. Forrest J. Remick 305 East Hamilton Avenue State College. Pennsylvania 16801

SEP TOPIC XV-7:

LOSS OF FORCED COOLANT FLOW, REACTOR COOLANT PUMP ROTOR SEIZURE AND SHAFT BREAK DRESDEN 2 NUCLEAR POWER PLANT

SUBJECT:

LOSS OF FORCED REACTOR COOLANT FLOW INCLUDING TRIP OF PUMP MOTOR AND FLOW CONTROLLER MALFUNCTIONS I.

INTRODUCTION A decrease in reactor coolant flow occuring while the plant is at power could result in a degradation of core heat transfer. A resulting increase in fuel temperature and accompanying fuel damage could then result if spe.:.

cified acceptable fuel damage limits are exceeded during the transient.

A number of transients that are expected to occur with moderate frequency and that result in a decrease in forced reactor coolant flow rate are addressed in SRP 15.3. l and SRP 15.3.2.

For boiling water reactors (BWRs}, partial and complete recirculation pump trips and malfunctions of the recirculation flow controller to cause decreasing flow are reviewed.

II.

REVIEW CRITERIA Section 50.34 of 10 CFR Part 50 requires that each applicant for an operating license provide an analysis and evaluation of the design and performance of structures, systems, and components of the facility with the objective of as-sessing the risk to public health and safety resulting from operation of the facility.

The loss of forced reactor coolant flow.is one of the postulated transients used to evaluate the adequacy of thes~ structures, systems and components with respect to the public health and safety.

Section 50.36 of 10 CFR Part 50 requires the Technical Specifications to in-clude safety limits which protect the integrity of the physical barriers which guard against the uncontrolled *release of radioactivity.

ii:r;uil'c'::,~*nts foi*

~:Ii~ prinr:ipal c:csiun criteria for 1-1ater-coole:d reactors.

Th2 st:iff.-.u:cpt(;nce criteria t:ii*e bJscd on meeting the relevi1nt requirements of the follm*1ing regu,lat-ions:

A.

Ge:1cral Dr,sign CrHr~i'ion 10 (Ref. 1), as it relutcs to the reactor coolJ11t ~ystcm being designed with appropriate margin to assure that c:.;Jecific*d ncc:~pt:.Jble fuel d:.:-sign l*;rnits iffe nut exceeded dui"ing i;Orn:al OjJCl",-itiOllS *j,-,cluding 6t1'i..icir:c;tcd Of'Cra'i:ional OCCUlTCnces.

B.

8;J;cral Dr:si~n Criterion 15 (Ref. 2), as it rclate:.:s to U1e reactor cr:.>olrrnt

~ystc1n and its associated 2uxilia1**ir.s being design~d 1*1ith appropriate margin to assure tl1at the pressure boundary \\'/ill not be breeched during normal operations including anticipated opera-tional occurrences.

C.

General Design Criterion 26 (Ref. 3) as it relates to the reliable control of reactivity changes to assure that specified acceptable fuel design limits are not exceeded, including anticipated opera-tional occurrences.

This is accomplished by assuring that appro-priate margin for malfunctions, such as stuck rods, are accounted for.

The specific criteria necessary to meet the relevant requirements of GDC 10, 15 and 26 for incidents of moderate frequency are:

a.

Pressure in the reactor coolant and main steam systems should be maintained below 110% of the design values.

b.

Fuel cladding integrity shall be maintained by ensuring that the ri1i1iirnum DNBR remains above the 95/95 ONBR 1 imit for PHRs and the CPR reillains above the MCPR safety 1 imit for Bl*JRs based on accept-able correlations (see SRP Section 4.4).

c.

An incident of moderate freqtiency should not gen~rate a more serious pl ant condition \\*1ithout other faults occurrjng i n<iependently.

d.

An incident of moderate ~i~quency in combination with any single ac-tive component failure, or single operator error, shall be conside1'ed and is an event for which an estimate ~f the number of potential fuel fa i1 ures shall be provided for radiological dose ca lcul at ions.

For such accidents, the number of fuel.faflures must be assumed for all rnds for which the DNBR or CPR falls below those values ci..ted. above for cladding integrity unless it can be shown, based on an acceptable fuel damage model (see SRP Section 4.2), that fe\\'1er failures occur.

There shall be no loss of function of any fission product barrier other than the fuel cladding.

III. RELATED SAFETY TOPICS Various other SEP topics evaluate such items as the reactor protection system.

The effects of single failures on safe shutdown capability are considered under

  • Topic VII-3.

IV.

REVIEW GUIDELINES The review is conducted in accordance with SRP sections 15.3. 1 and 15.3.2. The evaluation includes reviews of the analysis for the event and identification of the features in the pl ant that mitigate the consequences of the event as well as the ability of these systems to function as required.

The extent to which operator action is required is also evaluated. Deviations from the criteria specified in the Standard Review Plan are identified.

V.

EVALUATION The licensee, in a letter dated October 15, 1981, and Section 4.3.3 of the FSAR, provides the results of an analysis for the subject topic. The analysis indi-cates that a loss of reactor coolant flow can result from loss of power to the pump, failure of the motor generator (M-G) set speed controller, or failure

  • of the pum.p.

The decreasing core flow causes a core heat-up due to the flow-power mismatch.* The increased void formation inserts negative reactivity to drop power back to a level compatible with the lower flow.

No reactor trips occur due to the decreased flow.

During power operation, there are two reactor coolant recirculation pumps in operation. The Dresden* 2 is also permitted to operate with only one reactor coolant recirculation pump for four weeks at 50%

power.

The results of the licensee's analysis show that. during this event the

.reactor coolant pressure is decreasing and the minimum critical heat flux ratio (MCHF~) is increasi~g.

The licensee has not provided the results of an analysis for this event in com-bination with a single failure. Since this event, however, does not cause a reactQr trip or any engineered safety feature initiation during this transient

we cou:ld not identify any single failure which will lead to unacceptable results.

VI.

CONCLUSIONS The staff concludes that the Dresden 2 plant design with regard to transients that are expected to occur during plant life and result in a loss or decrease in forced reactor coolant flow is acceptable and meets the relevant requirements of General Design Criteria 10, 15, and 26.

This conclusion is based on the foll owing:

1.

The applicant has met the requirements of GDC 10 and 26 with respect to demonstrating that the specified acceptable fuel design limits are not exceeded for this event.

This requirement has been met since the results of the analysis showed that the thermal margin limits (MCHFR) are satisfied.

2.

The applicant has met the requirements of GDC 15 with respect to dem-onstrating that the reactor coolant pressure boundary limits have not been exceeded for this event.

This requirement has been met since the analysis showed that the maximum pressure of the reactor coolant and main steam systems did not exceed 110% of the design pressure.

3.

The applicant has met the requirements of GDC 26 with respect to the capability of the reactivity control system to provide adequate con-trol of.reactivity during this event while including appropriate mar-gin for stuck rods since the specific acceptable fuel design limits were not exceeded.

J 1 t DRESDEN 2

SUBJECT:

REACTOR COOLANT PUMP ROTOR SEIZURE AND REACTOR COOLANT PUMP SHAFT.BREAK I.

INTRODUCTION The events postulated are an instantaneous seizure of the rotor or break of the shaft of a reactor coolant pump in a pressurized water reactor {P\\~R) or recirculation pump in a b_oil ing water reactor {BWR).

Flow through the aff-ected loop is rapidly reduced.

The sudden decrease in core coolant flow while the reactor is at power results in a degradation of core heat transfer which could result in fuel damage.

The initial rate of reduction of coolant flow is greater for the rotor seizure event. However, the shaft break event permits a greater reverse flow through the affected loop later during the transient and, therefore, results in a lower core flow rate later in time.

This topic is intended to cover both of these accidents.

II.

REVIEW CRITERIA Section 50.34 of 10 CFR Part 50 requires that each applicant for an opera-ting license provide an analysis and evaluation of the *design and perfor-mance of structures, systems, and components of the facility with the ob-jective of assessing the risk to public health and safety resulting from operation of the facility.

The reactor coolant pump rotor seizure and re-actor coolant pump shaft break are two of the postulated accidents used to evaluate the adequacy of these structures, systems, and components with respect to the public health and safety.

Section 50.36 of 10 CFR Part 50 requires the Technical Specifications to include safety limits which protect the integrity of the physical barriers

" which guard against the uncontrolled release of radioactivity.

The General Design Criteria (Appendix A to 10 CFR Part 50) establish minimum requirements for the principal design criteria for water-cooled reactors.

GOS 27 "Combined Reactivity Control System Capability", requires that the reactivity control systems, in conjunction with poison addition by the emer-gency core cooling system, has the capability to reliably control reactivity changes to assure that under postulated accident conditions, and with appro-priate margin for stuck rods, the capability to cool the core is maintained.

GDC 28 "Reactivity Limits" requires that the reactivity control systems be designed with appropriate limits on the potential amount and rate of reacti-vity increase to ensure that the effects of postulated reactivity accidents can neither (1) result in damage to the reactor coolant pressure boundary*

greater than limited local yielding nor (2) sufficiently disturb the core, its support structures or other reactor pressure vessel internals to impair significantly the capability to cool the core.

GDC 31 "Fracture Prevention of Reactor Coolant Pressure Boundary" requires that the boundary be designed with sufficient margin to assure that when stressed under operating, maintenance, testing, and postulated accident con-ditions.(1) the boundary behaves in a nonbrittle manner and (2) the proba-bility of rapidly propgating fractures is minimized.

10 CFR Part 100.11 provides dose guidelines for reactor siting against which calculated accident dose consequences may be compared..

III.

RELATED SAFETY TOPICS Various other SEP topics evaluate such items as the reactor protection system.

The effects of single failures on safe shutdown capability are considered under Topic VII-3 IV.

REVIEW GUIDELINES The review is conducted in accordance with SRP Sections 15.3.3, 15.3.4. The evaluation includes review of the analysis for the event and identification of the features in the plant that mitigate the consequences of the event as well as the ability of these systems to function as required.

The extent to which operator action is required is also evaluated.

Deviations from the criteria specified in the Standard Review Plan are identified.

V.

EVALUATION The licensee, in letters dated May 27, 1981 *and October 15, 1981, and in Section 4.3.3 of the FSAR, provides the results of an analysis for the subject topic.

The licensee does not address the pump shaft break accident in his analysis.

However, the results of analyses for other BWR plants indicated that the single reactor coolant recirculation pump rotor seizure is more limiting than the pump shaft break accident. This is because it produces a greater initial power to flow mismatch and more of a decrease in the minimum critical power ratio (MCPR).

The single reactor coolant recirculation pump shaft break has a less severe effect with respect to MCPR.

The analysis indicates that, after a single reactor coolant recirculation pump seizure, the reactor power decreases in response to the reduced circulation flow.

No reactor trip occurs and therefore, a loss of offsite power following turbine trip need not be assumed in this accident analysis.

During power operation, there are two reactor coolant recirculation pumps in operation.

Dresden 2 is also permitted to operate with only one reactor coolant re-circulation pump for four weeks at 50% power.

The results of the licensee analysis show that the single reactor coolant recirculation pump rotor seizure during either one or two pump operation will have an MCHFR higher than allowable MCHFR for Dresden 2.

The results of the licensee's analysis also show

  • .that the reactor coolant pressure will increase slightly during the first two seconds after the acc.1dent and decrease during the remaining of the transient.

The licensee has not provided the results of an analysis for this event in combination with a single failure.

Since this event does not cause a reactor trip or any engineered safety feature initiation dl,Jring this transient, we could not identify any single failure which wo.uld lead to unacceptable results.

. VI.

CONCLUSIONS The staff concludes that the consequences of a postulated reactor coolant re-circulation pump rotor seizure or broken shaft event meet the requirements set forth in the General *oesign Criteria 27, 28, and 31 regarding control rod insertability and core coolability.

This conclusion is based upon the. following:

1.

The li~ensee has demonstrated that there is no fuel damage as a result of a postulated reactor coolant recirculation pump rotor seizure acci-dent, because the Minimum Critical Heat Flux Ratio (MCHF.R) remains above the allowable MCHFR limit.

2.. The. requirements of GDC 31 are met with respect.to integrity of the primary system boundary to withstand the postulated accident.

e.

SEP TOPIC XV-15 DRESDEN 2 NUCLEAR POWER PLANT

SUBJECT:

Inadvertent Opening of a BWR Safety/Relief Valve I.

INTRODUCTION The inadvertent opening of a safety or relief valve results in a reactor coolant inventory decrease and a decrease in reactor coolant system pressure.

Neutron flux decreases due to additional void formation.

A failed open relief valve blows down to the suppression pool.

The safet.v valves discharge directly to drywell atmosphere.

On relief valve opening, the pressure.regulator senses the pressure decrease and partially closes the turbine control valves.

No reactor trip occurs, and condi-tions stabilize at a power level near the initial power.

The feedwater system is used to makeup the.continuing loss of inventory.

Should the feedwater system become unavailable due to a single failure of loss of offsite power, the high pressure coolant injection {HPCI) system could provide water.

HPCI would be automatically actuated on low-low water level.

If the pressure regulator fails to respond, the increased steam flow would cause a decrease in steam pressure and close the main steam isolation valves {MSIV's).

This event has been discussed in Section 1.3 of the report submitted by Commonwealth Edison on October 15, 1981 (Reference 1).

If a Power Actuated Relief Valve (PARV) opens and fails to reclose, the torus could experience an increase in temperature since relief valves discharge into the torus.

Closure of the MSIV's would not halt the blowdown since the relief valves are upstream of the isolation valves.

' t,

' l I

l I.

I II.

REVIEW CRITERIA Section 50.34 of 10 CFR Part 50 requires that each applicant for a construction pennit or operating license provide an analysis and evaluation of the design and perfonnance of structures, systems, and components of the facility with the objective of assessing the risk to public health and safety resulting from operation of the facility, including detennination of the margin of safety during nonnal operational and transient conditions anticipated during the life of the facility.

Section 50.36 of 10 CFR Part 50 requires the Technical Specifications to include safety limits which protect the integrity of the physical barriers which guard against the uncontrolled release of radioactivity. The General Design Criteria

{Appendix A' to 10. CFR Part 50) establish minimum requirements for the prin'Cipal design criteria for water-cooled reactors.

GDC 10 "Reactor Design" requires that the core and associated coolant control and protection systems be designed wi.th appropriate margin to assure that speci-fic acceptable fu'el design limits are not *exceeded during normal operation, including the effects of anticipated operational occurrences.

GDC 15 "Reactor Coolant System Design" requires that the reactor coolant and associated protection systems be designed with sufficient margin to assure that the design conditions of the reactor coolant pressure boundary are not exceeded during normal.operation, including the effects of anticipated operational occurrences.

GDC 26 "Reactivity Control System Redundancy and Capability" requires that the reactivity control systems be capable of reliably controlling reactivity changes,."

to assure that under conditions of normal operation, including anticipated opera-tional occurrences, and with appropriate margin for malfunctions such as stuck

. *. rods, s*pecified a,ccepta,ble fuel des:1~n 111TJits a.re not exceeded.

III.

RELATED SAFETY TOPICS Various other SEP topics discuss such items as the Engineered Safety Features (ESF) and containment cooling systems.

Topic XV-19 reviews the spectrum of loss of coolant accidents.

IV.

REVIEW GUIDELINES The review i~ conducted in accordance with SRP 15.6.1.

The evaluation includes review of the analysis for the event and identification of the features in the plant that mitigate the consequences of the event as well as the ability of these systems to function as required.

The extent to which j

operator action is required is also evaluated.

Deviations f~om the criteria specified in the Standard Review Plan are identiffed.

V. EVALUATION Inadvertent opening of a safety/relief valve causes a negligible pressure reduction due to partical closure of the turbine control valve by the pressure regulator.

The net change in power level and coolant conditions within the fuel assemblies is negligible and operating thermal margins are relatively unaffected.

Therefore, minimum critical power ratio (MCPR) will not change significantly.

The licensee has submitted an evaluation of this SEP to~ic in Reference 1 and has referred to the accident analysis of Reference 2.

However, this analysis (Ref.2) generically evaluates the effects of stuck open relief valves as an inventory threatenins event.

The purpose of this analysis was to show no fuel uncovery for this event.

The intent of Reference 2 was not to look at MCPR as required by Standard Review Plan (SRP) Chapter 15.

References 1 and 2 did not address the potential for fuel failure as a result of this transient.

On the basis of our evaluation iof other similar plants (Referenc~j and 4) the staff feels, however, that there wil.l not be any fuel failure due to stuck open relief valve event since MCPR does not change much as discus~ed above in th1 preceeding paragraph. Therefore, no addition a 1 i.nformation is re qui red from the 1 i censee.

  • A possible singe failure that would affect the course of this event would be a failure in the feedwater system.

The failure of feedwater system will result in actuation of the HPCI.

There should not be any fuel failure as a consequence of feedwater system failure since (i) the MCPR will occur before actuation of HPCI, (ii) there will not be any fuel uncovery, and (iii) either natural circulation or forced flow is sufficient to prevent boiling transition at decay heat power level.

The effect of the inadvertent safety/relief valve opening on the suppression pool temperature is treated separately in Unresolved Safety Issue A-39.

VI.

CONCLUSION As part of the SEP review of Dre~den 2 Nuclear Power Plant, the analysis presented by the licensee has been evaluated against the criteria of SRP Section 15.6.1 and found to be in conformance with the acceptance criteria.

VII.

REFERENCES

1. Transmitting Accident and Transient Topic Assessments Letter, T. Rausch (Commonwealth Edison) to D. Crutchfield (NRC), for the Dresden 2 Nuclear Power Plant, Docket No. 50-237, October 15, 1981.
2.

NED0-24708A - August 1979 Rev. 1 - December 1980, Additional Information Required for NRC Staff Generic Report on Boiling Water Reactors Volumes 1 and 2 (Section 3.5.2.1.7).

3.

Letter, D. Crutchfield (NRC) to W. Counsil (Northeast Nuclear Energy Co.)

October 28, 1981.

Subject:

SEP Topic XV-15 for Millstone 1 (Docket 50-245).

4.

Letter, D. Crutchfield (NRC) to I. Finfrock (Jersey Central Power & Light Co.)

December 4, 1981.

Subject:

SEP Topic XV-15 for Oyster Creek (Docket 50-219).