Issues with Technical Specification Task Force Traveler TSTF-505, Revision 1, Provide Risk-Informed Extended Completion Times - RITSTF Initiative 4B
ML16300A245
Person / Time
Site: Beaver Valley, Millstone, Hatch, Monticello, Calvert Cliffs, Dresden, Davis Besse, Peach Bottom, Browns Ferry, Salem, Oconee, Mcguire, Nine Mile Point, Palisades, Palo Verde, Perry, Indian Point, Fermi, Catawba, Harris, Wolf Creek, Saint Lucie, Point Beach, Oyster Creek, Watts Bar, Hope Creek, Grand Gulf, Cooper, Sequoyah, Byron, Pilgrim, Arkansas Nuclear, Braidwood, Susquehanna, Summer, Prairie Island, Columbia, Seabrook, Brunswick, Surry, Limerick, North Anna, Turkey Point, River Bend, Ginna, Diablo Canyon, Callaway, Vogtle, Waterford, Duane Arnold, Farley, Robinson, Clinton, South Texas, Cook, Comanche Peak, Quad Cities, Fort Calhoun, FitzPatrick, McGuire, LaSalle, Crane
(DPR-016, DPR-018, DPR-019, DPR-020, DPR-022, DPR-023, DPR-024, DPR-025, DPR-026, DPR-027, DPR-029, DPR-030, DPR-031, DPR-032, DPR-033, DPR-035, DPR-037, DPR-038, DPR-040, DPR-041, DPR-042, DPR-044, DPR-046, DPR-047, DPR-049, DPR-050, DPR-051, DPR-052, DPR-053, DPR-055, DPR-056, DPR-057, DPR-058, DPR-059, DPR-060, DPR-062, DPR-063, DPR-064, DPR-065, DPR-066, DPR-067, DPR-068, DPR-069, DPR-070, DPR-071, DPR-074, DPR-075, DPR-077, DPR-079, DPR-080, DPR-082, NPF-002, NPF-003, NPF-004, NPF-005, NPF-006, NPF-007, NPF-008, NPF-009, NPF-011, NPF-012, NPF-014, NPF-016, NPF-017, NPF-018, NPF-021, NPF-022, NPF-029, NPF-030, NPF-035, NPF-037, NPF-038, NPF-039, NPF-041, NPF-042, NPF-043, NPF-047, NPF-049, NPF-051, NPF-052, NPF-057, NPF-058, NPF-062, NPF-063, NPF-066, NPF-068, NPF-069, NPF-072, NPF-073, NPF-074, NPF-076, NPF-077, NPF-080, NPF-081, NPF-085, NPF-086, NPF-087, NPF-089, NPF-090, NPF-096)
Issue date: 11/15/2016
From: Boland A
Division of Operating Reactor Licensing
To: Bement R, Boles B, Capps S, Coffey R, Diya F, Fessler P, Franssen R, Gardner P, Gebbie J, William Gideon, Glover R, Halpin E, Hamilton D, Hamilton T, Bryan Hanson, Heacock D, Heflin A, Limpias O, Lippard G, Marik S, Mccartney E, Nazar M, Northard S, Peters K, Pierce C, Gerry Powell, Teresa Ray, Reddemann M, Richey M, Sena P, James Shea, Simril R, Vehec T
Arizona Public Service Co, Calvert Cliffs, Dominion Nuclear Connecticut, DTE Electric Company, Duke Energy Carolinas, Duke Energy Progress, Energy Northwest, Entergy Nuclear Operations, Entergy Operations, Exelon Generation Co, Exelon Nuclear, FirstEnergy Nuclear Operating Co, Florida Power & Light Co, Indiana Michigan Power Co, Nebraska Public Power District (NPPD), NextEra Energy Duane Arnold, Point Beach, NextEra Energy Seabrook, Northern States Power Company, Minnesota, Omaha Public Power District, Pacific Gas & Electric Co, Public Service Enterprise Group, South Carolina Electric & Gas Co, South Texas, Southern Nuclear Operating Co, Susquehanna, Tennessee Valley Authority, TEX Operations Company, Union Electric Co, Virginia Electric & Power Co (VEPCO), Wolf Creek
Miller G
References
Download: ML16300A245 (13)


Text

UNITED STATES NUCLEAR REGULATORY COMMISSION WASHINGTON, D.C. 20555-0001 All Operating Reactor Licensees (See Enclosed List)

November 15, 2016

SUBJECT:

ISSUES WITH TECHNICAL SPECIFICATION TASK FORCE TRAVELER TSTF-505, REVISION 1, "PROVIDE RISK-INFORMED EXTENDED COMPLETION TIMES-RITSTF INITIATIVE 4B" The purpose of this letter is to inform licensees with a risk-informed completion time (RICT) license amendment request under review or those who may intend to submit an RICT license amendment request, that the U.S. Nuclear Regulatory Commission (NRC) has suspended approval of the subject Technical Specification Traveler. The NRC staff communicated this action to the Technical Specification Task Force via letter dated November 15, 2016 (Agencywide Documents Access and Management System Accession No. ML16281A021).

This letter also contains a summary of concerns that the NRC staff has identified during review of plant-specific license amendments requesting adoption of the Traveler.

As indicated in the letter, the NRC staff will continue to review those applications that are currently under review as plant-specific licensing actions. Additional interactions with licensees will continue to evaluate site-specific proposals to address the identified concerns. The NRC staff will communicate ongoing efforts affecting the in-house applications, and will issue requests, if needed, to individual licensees to resolve any outstanding informational needs.

If you have any questions on this matter, please contact your assigned plant Project Manager.

Enclosure:

List of Operating Reactor Licensees cc:

Distribution via Listserv Sincerely,

~ftlll#{_

Anne T. Boland, Director Division of Operating Reactor Licensing Office of Nuclear Reactor Regulation

LIST OF OPERATING REACTOR LICENSEES Arkansas Nuclear One. Units 1 and 2 Entergy Operations, Inc.

Docket Nos. 50-313 and 50-368 License Nos. DPR-51 and NPF-6 Vice President, Operations Arkansas Nuclear One Entergy Operations, Inc.

1448 S.R. 333 Russellville, AR 72802 Beaver Valley Power Station. Units 1 and 2 FirstEnergy Nuclear Operating Company Docket Nos. 50-334 and 50-412 License Nos. DPR-66 and NPF-73 Mr. Marty L. Richey Site Vice President FirstEnergy Nuclear Operating Company Beaver Valley Power Station Mail Stop A-BV-SEB1 P.O. Box 4, Route 168 Shippingport, PA 15077 Braidwood Station. Units 1 and 2 Exelon Generation Company, LLC Docket Nos. STN 50-456 and STN 50-457 License Nos. NPF-72 and NPF-77 Mr. Bryan C. Hanson Senior Vice President Exelon Generation Company, LLC President and Chief Nuclear Officer (CNO)

Exelon Nuclear Braidwood Station 4300 Winfield Road Warrenville, IL 60555 Browns Ferry Nuclear Plant. Units 1. 2, and 3 Tennessee Valley Authority Docket Nos. 50-259, 50-260, and 50-296 License Nos. DPR-33, DPR-52, and DPR-68 Mr. Joseph W. Shea Vice President, Nuclear Licensing Tennessee Valley Authority Browns Ferry Nuclear Plant 1101 Market Street, LP 3R-C Chattanooga, TN 37402-2801 Brunswick Steam Electric Plant, Units 1 and 2 Duke Energy Progress, LLC Docket Nos. 50-325 and 50-324 License Nos. DPR-71 and DPR-62 Mr. William R. Gideon Site Vice President Brunswick Steam Electric Plant 8470 River Rd., SE (M/C BNP001)

Southport, NC 28461 Byron Station. Units 1 and 2 Exelon Generation Company, LLC Docket Nos. STN 50-454 and STN 50-455 License Nos. NPF-37 and NPF-66 Mr. Bryan C. Hanson Senior Vice President Exelon Generation Company, LLC President and Chief Nuclear Officer (CNO)

Exelon Nuclear Byron Station 4300 Winfield Road Warrenville, IL 60555 Enclosure

Callaway Plant, Unit 1 Union Electric Company Docket No. 50-483 License No. NPF-30 Mr. Fadi Diya Senior Vice President and Chief Nuclear Officer Union Electric Company Callaway Plant P.O. Box 620 Fulton, MO 65251 Calvert Cliffs Nuclear Power Plant. Units 1 and 2 Calvert Cliffs Nuclear Power Plant, LLC Docket Nos. 50-317 and 50-318 License Nos. DPR-53 and DPR-69 Mr. Bryan C. Hanson President and Chief Nuclear Officer Exelon Generation Company, LLC Calvert Cliffs Nuclear Power Plant 4300 Winfield Road Warrenville, IL 60555 Catawba Nuclear Station. Units 1 and 2 Duke Energy Carolinas, LLC Docket Nos. 50-413 and 50-414 License Nos. NPF-35 and NPF-52 Mr. Robert T. Simril Site Vice President Duke Energy Carolinas, LLC Catawba Nuclear Station 4800 Concord Road York, SC 29745 Clinton Power Station, Unit 1 Exelon Generation Company, LLC Docket No. 50-461 License No. NPF-62 Mr. Bryan C. Hanson Senior Vice President Exelon Generation Company, LLC President and Chief Nuclear Officer (CNO)

Exelon Nuclear Clinton Power Station 4300 Winfield Road Warrenville, IL 60555 Columbia Generating Station Energy Northwest Docket No. 50-397 License No. NPF-21 Mr. Mark E. Reddemann Chief Executive Officer Energy Northwest Columbia Generating Station MD 1023 North Power Plant Loop P.O. Box 968 Richland, WA 99352-0968 Comanche Peak Nuclear Power Plant, Units 1 and 2 TEX Operations Company, LLC Docket Nos. 50-445 and 50-446 License Nos. NPF-87 and NPF-89 Mr. Ken J. Peters Senior Vice President & Chief Nuclear Officer Attention: Regulatory Affairs TEX Operations Company, LLC Comanche Peak Nuclear Power Plant P.O. Box 1002 Glen Rose, TX 76043

Cooper Nuclear Station Nebraska Public Power District Docket No. 50-298 License No. DPR-46 Mr. Oscar A. Limpias Vice President-Nuclear and CNO Nebraska Public Power District Cooper Nuclear Station 72676 648A Avenue Brownville, NE 68321 Davis-Besse Nuclear Power Station. Unit 1 FirstEnergy Nuclear Operating Company Docket No. 50-346 License No. NPF-3 Mr. Brian D. Boles Site Vice President FirstEnergy Nuclear Operating Company Davis-Besse Nuclear Power Station 5501 N. State Route 2 Mail Stop A-DB-3080 Oak Harbor, OH 43449-9760 Diablo Canyon Power Plant. Units 1 and 2 Pacific Gas and Electric Company Docket Nos. 50-275 and 50-323 License Nos. DPR-80 and DPR-82 Mr. Edward D. Halpin Senior Vice President, Generation and Chief Nuclear Officer Pacific Gas and Electric Company Diablo Canyon Power Plant P.O. Box 56, Mail Code 104/6 Avila Beach, CA 93424 Donald C. Cook Nuclear Plant, Units 1 and 2 Indiana Michigan Power Company Docket Nos. 50-31 5 and 50-316 License Nos. DPR-58 and DPR-74 Mr. Joel P. Gebbie Senior Vice President and Chief Nuclear Officer Indiana Michigan Power Company Nuclear Generation Group Donald C. Cook Nuclear Plant One Cook Place Bridgman, Ml 49106 Dresden Nuclear Power Station. Units 2 and 3 Exelon Generation Company, LLC Docket Nos. 50-237 and 50-249 License Nos. DPR-19 and DPR-25 Mr. Bryan C. Hanson Senior Vice President Exelon Generation Company, LLC President and Chief Nuclear Officer (CNO)

Exelon Nuclear Dresden Nuclear Power Station 4300 Winfield Road Warrenville, IL 60555 Duane Arnold Energy Center NextEra Energy Duane Arnold, LLC Docket No. 50-331 License No. DPR-49 Mr. Thomas A. Vehec Vice President NextEra Energy Duane Arnold Energy Center 3277 DAEC Road Palo, IA 52324-9785

Edwin I. Hatch Nuclear Plant. Units 1 and 2 Southern Nuclear Operating Company, Inc.

Docket Nos. 50-321 and 50-366 License Nos. DPR-57 and NPF-5 Mr. C. R. Pierce Regulatory Affairs Director Southern Nuclear Operating Company, Inc.

Edwin I. Hatch Nuclear Plant P.O. Box 1295 I Bin 038 Birmingham, AL 35201-1295 Fermi 2 DTE Electric Company Docket No. 50-341 License No. NPF-43 Mr. Paul Fessler, Senior Vice President and Chief Nuclear Officer DTE Electric Company Fermi 2 - 210 NOC 6400 North Dixie Highway Newport, Ml 48166 Fort Calhoun Station. Unit 1 Omaha Public Power District Docket No. 50-285 License No. DPR-40 Mr. Shane M. Marik Site Vice President and Chief Nuclear Officer Omaha Public Power District Fort Calhoun Station 961 O Power Lane, Mail Stop FC-2-4 Blair, NE 68008 Grand Gulf Nuclear Station. Unit 1 Entergy Operations, Inc.

Docket No. 50-416 License No. NPF-29 Vice President, Operations Entergy Operations, Inc.

Grand Gulf Nuclear Station P.O. Box 756 Port Gibson, MS 39150 H.B. Robinson Steam Electric Plant. Unit 2 Duke Energy Progress, LLC Docket No. 50-261 License No. DPR-23 Mr. Richard Michael Glover Site Vice President H. B. Robinson Steam Electric Plant Duke Energy Progress, LLC 3581 West Entrance Road, RNPA01 Hartsville, SC 29550 Hope Creek Generating Station PSEG Nuclear, LLC Docket No. 50-354 License No. NPF-57 Mr. Peter P. Sena, Ill President and Chief Nuclear Officer PSEG Nuclear LLC - N09 Hope Creek Generating Station P.O. Box 236 Hancocks Bridge, NJ 08038 Indian Point Nuclear Generating Units 1. 2.

and 3 Entergy Nuclear Operations, Inc.

Docket Nos. 50-247 and 50-286 License Nos. DPR-26 and DPR-64 Vice President, Operations Entergy Nuclear Operations, Inc.

Indian Point Energy Center 450 Broadway, GSB P.O. Box 249 Buchanan, NY 10511-0249 James A. FitzPatrick Nuclear Power Plant Entergy Nuclear Operations, Inc.

Docket No. 50-333 License No. DPR-59 Vice President, Operations Entergy Nuclear Operations, Inc.

James A. FitzPatrick Nuclear Power Plant P.O. Box 110 Lycoming, NY 13093

Joseph M. Farley Nuclear Plant. Units 1 and 2 Southern Nuclear Operating Company, Inc.

Docket Nos. 50-348 and 50-364 License Nos. NPF-2 and NPF-8 Mr. C. R. Pierce Regulatory Affairs Director Southern Nuclear Operating Company, Inc.

Joseph M. Farley Nuclear Plant P.O. Box 1295 I Bin 038 Birmingham, AL 35242 LaSalle County Station. Units 1 and 2 Exelon Generation Company, LLC Docket Nos. 50-373 and 50-37 4 License Nos. NPF-11 and NPF-18 Mr. Bryan C. Hanson Senior Vice President Exelon Generation Company, LLC President and Chief Nuclear Officer (CNO)

Exelon Nuclear LaSalle County Station 4300 Winfield Road Warrenville, IL 60555 Limerick Generating Station. Units 1 and 2 Exelon Generation Company, LLC Docket Nos. 50-352 and 50-353 License Nos. NPF-39 and NPF-85 Mr. Bryan C. Hanson President and Chief Nuclear Officer Exelon Nuclear Limerick Generating Station 4300 Winfield Road Warrenville, IL 60555 McGuire Nuclear Station, Units 1 and 2 Duke Energy Carolinas, LLC Docket Nos. 50-369 and 50-370 License Nos. NPF-9 and NPF-17 Mr. Steven D. Capps, Vice President Duke Energy Carolinas, LLC McGuire Nuclear Station 12700 Hagers Ferry Road Huntersville, NC 28078-8985 Millstone Power Station. Units 2 and 3 Dominion Nuclear Connecticut, Inc.

Docket Nos. 50-336 and 50-423 License Nos. DPR-65 and NPF-49 Mr. David A. Heacock President and Chief Nuclear Officer Dominion Nuclear Connecticut, Inc.

Millstone Power Station Innsbrook Technical Center 5000 Dominion Boulevard Glen Allen, VA 23060 Monticello Nuclear Generating Plant Northern States Power Company Docket No. 50-263 License No. DPR-22 Mr. Peter A. Gardner Senior Vice President and Chief Nuclear Officer Northern States Power Company - Minnesota Monticello Nuclear Generating Plant 2807 West County Road 75 Monticello, MN 55362-9637 Nine Mile Point Nuclear Station. Units 1 and 2 Nine Mile Point Nuclear Station, LLC Exelon Generation Company, LLC Docket Nos. 50-220 and 50-41 O License Nos. DPR-63 and NPF-69 Mr. Bryan C. Hanson President and Chief Nuclear Officer Exelon Generation Company, LLC Nine Mile Point Nuclear Station 4300 Winfield Road Warrenville, IL 60555

North Anna Power Station, Units 1 and 2 Virginia Electric and Power Company Docket Nos. 50-338 and 50-339 License Nos. NPF-4 and NPF-7 Mr. David A. Heacock, President and Chief Nuclear Officer Virginia Electric and Power Company North Anna Power Station Innsbrook Technical Center 5000 Dominion Boulevard Glen Allen, VA 23060 Oconee Nuclear Station, Units 1, 2, and 3 Duke Energy Carolinas, LLC Docket Nos. 50-269, 50-270, and 50-287 License Nos. DPR-38, DPR-47, and DPR-55 Mr. Thomas D. Ray Vice President Oconee Nuclear Station Duke Energy Corporation 7800 Rochester Highway Seneca, SC 29672-0752 Oyster Creek Nuclear Generating Station Exelon Generation Company, LLC Docket No. 50-219 License No. DPR-16 Mr. Bryan C. Hanson President and Chief Nuclear Officer Exelon Generation Company, LLC Oyster Creek Nuclear Generating Station 4300 Winfield Road Warrenville, IL 60555 Palisades Nuclear Plant Entergy Nuclear Operations, Inc.

Docket No. 50-255 License No. DPR-20 Vice President, Operations Entergy Nuclear Operations, Inc.

Palisades Nuclear Plant 27780 Blue Star Memorial Highway Covert, Ml 49043-9530 Palo Verde Nuclear Generating Station, Units 1, 2, and 3 Arizona Public Service Company Docket Nos. STN 50-528, STN 50-529, and STN 50-530 License Nos. NPF-41, NPF-51, and NPF-7 4 Mr. Robert S. Bement Executive Vice President Nuclear/

Chief Nuclear Officer Arizona Public Service Company Palo Verde Nuclear Generating Station P.O. Box 52034 Mail Station 7602 Phoenix, AZ 85072-2034 Peach Bottom Atomic Power Station, Units 2 and 3 Exelon Generation Company, LLC Docket Nos. 50-277 and 50-278 License Nos. DPR-44 and DPR-56 Mr. Bryan C. Hanson President and Chief Nuclear Officer Exelon Nuclear Peach Bottom Atomic Power Station 4300 Winfield Road Warrenville, IL 60555 Perry Nuclear Power Plant, Unit 1 FirstEnergy Nuclear Operating Company Docket No. 50-440 License No. NPF-58 Mr. David B. Hamilton Site Vice President FirstEnergy Nuclear Operating Company Perry Nuclear Power Plant Mail Stop A-PY-290 P.O. Box 97, 10 Center Road Perry, OH 44081-0097

Pilgrim Nuclear Power Station Entergy Nuclear Operations, Inc.

Docket No. 50-293 License No. DPR-35 Site Vice President Entergy Nuclear Operations, Inc.

Pilgrim Nuclear Power Station 600 Rocky Hill Road Plymouth, MA 02360-5508 Point Beach Nuclear Plant. Units 1 and 2 NextEra Energy Point Beach, LLC Docket Nos. 50-266 and 50-301 License Nos. DPR-24 and DPR-27 Mr. Robert Coffey Site Vice President NextEra Energy Point Beach, LLC 6610 Nuclear Road Two Rivers, WI 54241-9516 Prairie Island Nuclear Generating Plant.

Units 1 and 2 Northern States Power Company - Minnesota Docket Nos. 50-282 and 50-306 License Nos. DPR-42 and DPR-60 Mr. Scott D. Northard Acting Vice President Northern States Power Company - Minnesota Prairie Island Nuclear Generating Plant 1717 Wakonade Drive East Welch, MN 55089-9642 Quad Cities Nuclear Power Station. Units 1 and2 Exelon Generation Company, LLC Docket Nos. 50-254 and 50-265 License Nos. DPR-29 and DPR-30 Mr. Bryan C. Hanson Senior Vice President Exelon Generation Company, LLC President and Chief Nuclear Officer Exelon Nuclear Quad Cities Nuclear Power Station 4300 Winfield Road Warrenville, IL 60555 R. E. Ginna Nuclear Power Plant R. E. Ginna Nuclear Power Plant, LLC Exelon Generation Company, LLC Docket No. 50-244 License No. DPR-18 Mr. Bryan C. Hanson President and Chief Nuclear Officer Exelon Generation Company, LLC R. E. Ginna Nuclear Power Plant 4300 Winfield Road Warrenville, IL 60555 River Bend Station. Unit 1 Entergy Operations, Inc.

Docket No. 50-458 License No. NPF-47 Vice President, Operations Entergy Operations, Inc.

River Bend Station 5485 U.S. Highway 61 N St. Francisville, LA 70775

Salem Nuclear Generating Station. Units 1 and 2 PSEG Nuclear, LLC Docket Nos. 50-272 and 50-311 License Nos. DPR-70 and DPR-75 Mr. Peter P. Sena, Ill President and Chief Nuclear Officer PSEG Nuclear LLC - N09 Salem Nuclear Generating Station P.O. Box 236 Hancocks Bridge, NJ 08038 Seabrook Station. Unit 1 NextEra Energy Seabrook, LLC Docket No 50-443 License No. NFP-86 Mr. Eric McCartney Site Vice President NextEra Energy Seabrook Station 626 Lafayette Rd.

Seabrook, NH 03874 Sequoyah Nuclear Plant. Units 1 and 2 Tennessee Valley Authority Docket Nos. 50-327 and 50-328 License Nos. DPR-77 and DPR-79 Mr. Joseph W. Shea Vice President, Nuclear Licensing Tennessee Valley Authority Sequoyah Nuclear Plant 1101 Market Street, LP 3R-C Chattanooga, TN 37402-2801 Shearon Harris Nuclear Power Plant, Unit 1 Duke Energy Progress, LLC Docket No. 50-400 License No. NPF-63 Ms. Tanya Hamilton Site Vice President Duke Energy Progress, LLC Shearon Harris Nuclear Power Plant 5413 Shearon Harris Rd.

M/C HNP01 New Hill, NC 27562-0165 South Texas Project. Units 1 and 2 STP Nuclear Operating Company Docket Nos. 50-498 and 50-499 License Nos. NPF-76 and NPF-80 Mr. G. T. Powell Executive Vice President and CNO STP Nuclear Operating Company South Texas Project P.O. Box289 Wadsworth, TX 77483 St. Lucie Plant. Units 1 and 2 Florida Power and Light Company Docket Nos. 50-335 and 50-389 License Nos. DPR-67 and NPF-16 Mr. Mano Nazar President and Chief Nuclear Officer Nuclear Division Florida Power & Light Company Mail Stop: NT3/JW 15430 Endeavor Drive Jupiter, FL 33478

Surry Power Station, Units 1 and 2 Virginia Electric and Power Company Docket Nos. 50-280 and 50-281 License Nos. DPR-32 and DPR-37 Mr. David A. Heacock President and Chief Nuclear Officer Dominion Nuclear Virginia Electric and Power Company Surry Power Station Innsbrook Technical Center 5000 Dominion Boulevard Glen Allen, VA 23060-6711 Susquehanna Steam Electric Station. Units 1 and 2 Susquehanna Nuclear, LLC Docket Nos. 50-387 and 50-388 License Nos. NPF-14 and NPF-22 Mr. Robert J. Franssen Site Vice President Susquehanna Nuclear, LLC 769 Salem Boulevard NUCSB3 Berwick, PA 18603-0467 Three Mile Island Nuclear Station. Unit 1 Exelon Generation Company, LLC Docket No. 50-289 License No. DPR-50 Mr. Bryan C. Hanson President and Chief Nuclear Officer Exelon Generation Company, LLC Three Mile Island Nuclear Station 4300 Winfield Road Warrenville, IL 60555 Turkey Point Nuclear Generating Units 3 and 4 Florida Power and Light Company Docket Nos. 50-250 and 50-251 License Nos. DPR-31 and DPR-41 Mr. Mano Nazar President and Chief Nuclear Officer Nuclear Division Florida Power & Light Company Mail Stop: NT3/JW 15430 Endeavor Drive Jupiter, FL 33478 Virgil C. Summer Nuclear Station. Unit 1 South Carolina Electric & Gas Company Docket No. 50-395 License No. NPF-12 Mr. George Lippard, Ill Vice President, Nuclear Operations South Carolina Electric & Gas Company Virgil C. Summer Nuclear Station P.O. Box 88, Mail Code 800 Jenkinsville, SC 29065 Vogtle Electric Generating Plant. Units 1 and 2 Southern Nuclear Operating Company, Inc.

Docket Nos. 50-424 and 50-425 License Nos. NPF-68 and NPF-81 Mr. C. R. Pierce Regulatory Affairs Director Vogtle Electric Generating Plant Southern Nuclear Operating Company, Inc.

P.O. Box 1295 I Bin 038 Birmingham, AL 35201-1295 Waterford Steam Electric Station, Unit 3 Entergy Operations, Inc.

Docket No. 50-382 License No. NPF-38 Site Vice President Entergy Operations, Inc.

Waterford Steam Electric Station 17265 River Road Killona, LA 70057-3093

Watts Bar Nuclear Plant. Units 1 and 2 Tennessee Valley Authority Docket No. 50-390 and 50-391 License No. NPF-90 and NPF-96 Mr. Joseph W. Shea Vice President, Nuclear Licensing Tennessee Valley Authority Watts Bar Nuclear Plant 1101 Market Street, LP 3R-C Chattanooga, TN 37402-2801 Wolf Creek Generating Station Wolf Creek Nuclear Operating Corporation Docket No. 50-482 License No. NPF-42 Mr. Adam C. Heflin President, Chief Executive Officer, and Chief Nuclear Officer Wolf Creek Nuclear Operating Corporation Wolf Creek Generating Station P.O. Box 411 Burlington, KS 66839

ML16300A245 OFFICE NRR/DORL/111-2/BC(A)

NRR/DORL/LPLIV-1 /LA NRR/DORL/D NAME GEMiller JBurkhardt ABoland DATE 11/14/16 11/07/16 11/15/16

Letter to All Operating Reactor Licensees on the Enclosed List from Anne T. Boland Dated November 15, 2016

SUBJECT:

ISSUES WITH TECHNICAL SPECIFICATION TASK FORCE TRAVELER TSTF-505, REVISION 1, "PROVIDE RISK-INFORMED EXTENDED COMPLETION TIMES-RITSTF INITIATIVE 4B" DISTRIBUTION:

PUBLIC RidsNrrDorl Resource RidsNrrOd Resource RidsNrrDorlLpl 1-1 Resource RidsNrrDorlLpl1-2 Resource RidsNrrDorlLpl2-1 Resource RidsNrrDorlLpl2-2 Resource RidsNrrDorlLpl3-1 Resource RidsNrrDorlLpl3-2 Resource RidsNrrDorlLpl4-1 Resource RidsNrrDorlLpl4-2 Resource RidsNrrPMANO Resource RidsNrrPMBeaverValley Resource RidsNrrPMBraidwood Resource RidsNrrPMBrownsFerry Resource RidsNrrPMBrunswick Resource RidsNrrPMByron Resource RidsNrrPMCallaway Resource RidsNrrPMCalvertCliffs Resource RidsNrrPMCatawba Resource RidsNrrPMClinton Resource RidsNrrPMColumbia Resource RidsNrrPMComanchePeak Resource RidsNrrPMCooper Resource RidsNrrPMDavisBesse Resource RidsNrrPMDCCook Resource RidsNrrPMDiabloCanyon Resource RidsNrrPMDresden Resource RidsNrrPMDuaneArnold Resource RidsNrrPMFarley Resource RidsNrrPMFermi2 Resource RidsNrrPMFitzPatrick Resource RidsNrrPMFortCalhoun Resource RidsNrrPMGrandGulf Resource RidsNrrPMHatch Resource RidsNrrPMHopeCreek Resource RidsNrrPMlndianPoint Resource RidsNrrPMLaSalle Resource RidsNrrPMLimerick Resource RidsNrrPMMcGuire Resource RidsNrrPMMillstone Resource RidsNrrPMMonticello Resource RidsNrrPMNineMilePoint Resource RidsNrrPMNorthAnna Resource RidsNrrPMOconee Resource RidsNrrPMOysterCreek Resource RidsNrrPMPalisades Resource RidsNrrPMPaloVerde Resource RidsNrrPMPeachBottom Resource RidsNrrPMPerry Resource RidsNrrPMPilgrim Resource RidsNrrPMPointBeach Resource RidsNrrPMPrairielsland Resource RidsNrrPMQuadCities Resource RidsNrrPMREGinna Resource RidsNrrPMRiverBend Resource RidsNrrPMRobinson Resource RidsNrrPMSalem Resource RidsNrrPMSeabrook Resource RidsNrrPMSequoyah Resource RidsNrrPMShearonHarris Resource RidsNrrPMSouthTexas Resource RidsNrrPMStLucie Resource RidsNrrPMSummer Resource RidsNrrPMSurry Resource RidsNrrPMSusquehanna Resource RidsNrrPMThreeMilelsland Resource RidsNrrPMTurkeyPoint Resource RidsNrrPMVogtle Resource RidsNrrPMWaterford Resource RidsNrrPMWattsBar Resource RidsNrrPMWolfCreek Resource RidsNrrLABClayton Resource RidsNrrLAJBurkhardt Resource RidsNrrLAKGoldstein Resource RidsNrrLALRonewicz Resource RidsNrrLAPBlechman Resource RidsNrrLASRohrer Resource RidsRgn1 MailCenter Resource RidsRgn2MailCenter Resource RidsRgn3MailCenter Resource RidsRgn4MailCenter Resource