FPL Turkey Point Annual Post-Uprate Monitoring Report for Units 3 & 4 Uprate Project - August 2014 Section 2 2-18 Table 2.1-1. Statistical Summary of Automated Groundwater Specific Conductance (S/cm) 2013 2014 Post-Uprate Pre-Uprate Well Jun Jul Aug Sep Oct Nov Dec Jan Feb Mar Apr May Min Max Avg Std Dev Min Max Avg Std Dev TPGW-1S 58971 54288 46582 40260 41060 48528 51298 51568 51620 53262 51056 52173 39352 60685 50075 5600 47861 64171 56648 3331 TPGW-1M 71887 71961 71864 71762 71828 71397 71235 71477 71503 71332 71108 71250 70767 72165 71554 332 66640 75369 70952 1162 TPGW-1D 71396 71326 71279 71252 71102 70457 70430 70630 70702 70628 70024 70467 69853 71737 70817 480 69525 72580 71189 536 TPGW-2S 68408 67317 66043 67014 67748 67767 67682 67390 67403 67550 68212 69203 65498 72037 67690 989 68360 77088 73321 1631 TPGW-2M 75344 74854 74787 75345 75261 74745 74864 74341 74163 74268 74612 74901 73666 76234 74807 451 73143 77386 75263 773 TPGW-2D 76417 75732 74835 75444 75995 75484 75574 75514 75429 75301 74739 74795 74502 77182 75442 563 72128 77116 75491 476 TPGW-3S 64058 63567 64082 65116 65315 63875 62868 61476 60304 61449 60074 61994 54694 65637 62882 2026 61114 65491 63481 577 TPGW-3M 68387 68073 68120 68582 68484 67767 67692 67506 67325 67233 67671 67334 66557 68750 67858 493 66779 70236 68803 493 TPGW-3D 69585 69109 69211 69652 69694 69167 69149 68783 68605 68729 68769 68636 67967 70029 69101 432 66628 70014 68845 765 TPGW-4S 1538 1559 1769 NA 1854 2006 1859 1746 1966 2654 3135 3516 1251 5085 2159 672 1204 3867 2227 391 TPGW-4M 38751 38773 38844 NA 38637 38501 38511 38583 38577 39192 39809 39428 38149 39885 38886 494 35988 38785 37579 469 TPGW-4D 43230 43358 42977 42357 42636 42899 42882 42999 43017 42878 42513 42285 41934 43504 42838 359 41327 43986 42880 535 TPGW-5S 942 943 922 1003 905 885 863 837 797 790 791 818 692 1173 877 104 724 1947 1291 204 TPGW-5M 32821 32868 32936 32696 32683 32664 32629 32510 32475 32550 32267 32084 32023 33004 32601 247 29580 32438 30953 657 TPGW-5D 34344 34199 34312 34613 34487 34394 34170 34258 34360 34643 34595 34577 33883 34726 34412 194 31234 34077 33224 596 TPGW-6S 1082 1104 1150 1210 1207 1177 1183 1204 1215 1195 1171 1185 991 1231 1173 44 1044 1258 1147 57 TPGW-6M 22535 22518 22534 22512 22641 22535 22623 22808 22846 22749 22607 22524 22429 22943 22616 124 21669 23108 22603 272 TPGW-6D 23288 23315 23311 23307 23343 23610 23589 23467 23458 23453 23461 23527 22819 23659 23426 118 22537 24697 23641 248 TPGW-7S 529 530 525 526 523 NA NA 542 545 555 563 557 498 573 540 15 421 906 569 36 TPGW-7M 618 637 614 589 589 581 614 615 598 592 602 592 568 670 604 21 567 712 616 34 TPGW-7D 595 596 812 912 1140 1402 1653 2617 3191 3517 3959 4195 526 4323 1993 1335 418 679 592 19 TPGW-8S 2039 1845 1984 1971 2221 2073 1930 2105 1992 2067 2049 2010 1599 2302 2025 124 2067 3681 2878 348 TPGW-8M 634 NA 644 656 652 624 624 634 636 632 620 618 610 658 634 14 627 655 642 7

TPGW-8D 649 638 667 682 683 670 662 665 660 656 656 657 226 706 662 30 237 714 680 19 TPGW-9S 597 592 584 583 597 601 601 613 612 613 615 612 567 618 601 13 60 659 588 59 TPGW-9M 604 618 630 638 635 600 595 554 538 558 583 588 516 644 596 33 605 752 651 21 TPGW-9D 631 638 638 635 632 617 617 615 617 619 627 626 592 670 626 10 627 655 639 8

TPGW-10S 52468 52958 53057 52817 52791 52809 52974 53146 52965 52672 52505 53801 52034 54584 52913 385 50000 53163 51443 869 TPGW-10M 55058 55001 55101 55093 55171 54797 55256 55624 55513 55409 55361 55926 54514 56077 55272 341 53629 55812 54669 485 TPGW-10D 64717 65063 65204 65172 65295 65731 66325 66623 66422 66346 66294 66057 63546 66910 65749 674 53918 56544 55111 559 TPGW-11S 55416 55320 55584 55271 55072 54937 55347 55638 56541 55330 54574 55794 54433 56686 55401 555 53281 56001 54606 734 TPGW-11M 56638 56598 57632 57124 56703 57008 57255 57411 57768 58371 58758 57234 56349 59098 57374 679 54895 57774 56205 616 TPGW-11D 61371 61345 61175 61229 61300 61863 62163 62349 63257 62606 62228 62440 60938 63556 61933 668 55275 59311 58008 576 TPGW-12S 43645 NA 43963 43880 NA NA 43262 43745 43966 44278 44950 45847 38893 47520 44286 877 38736 45533 41280 984 TPGW-12M 64219 64766 65118 64905 64284 61452 61123 61660 61658 61289 60141 57997 56961 65554 62385 2191 58312 65338 63559 1178 TPGW-12D 64750 64677 64716 64326 64428 64116 65266 64582 64361 64483 64489 64185 63582 65573 64515 320 62948 65028 64032 399

FPL Turkey Point Annual Post-Uprate Monitoring Report for Units 3 & 4 Uprate Project - August 2014 Section 2 2-19 Table 2.1-1. Statistical Summary of Automated Groundwater Specific Conductance (S/cm) 2013 2014 Post-Uprate Pre-Uprate Well Jun Jul Aug Sep Oct Nov Dec Jan Feb Mar Apr May Min Max Avg Std Dev Min Max Avg Std Dev TPGW-13S 83681 83930 83896 84093 84097 83271 82961 82321 82076 81825 81708 81631 81384 85428 82968 984 81674 86909 84173 1191 TPGW-13M 79112 79426 79264 78816 78739 78752 78771 78448 78320 78060 77693 77695 77420 82175 78581 560 79026 83273 80759 1027 TPGW-13D 80765 81290 81157 79888 NA 80537 80897 80004 79742 79399 79112 79117 77542 82488 80172 850 80256 84564 82447 893 TPGW-14S 57606 58032 57687 57512 57303 57053 57301 57454 57573 57629 57607 56707 56564 58231 57448 377 56922 59860 58318 796 TPGW-14M 62941 63035 62718 62090 61900 61857 62340 62075 62089 62185 62249 61608 60917 64095 62260 505 61767 67002 63581 1014 TPGW-14D 73590 73673 73701 73963 73922 73389 73238 73989 74058 73624 73221 73767 72904 74537 73654 310 72365 75797 73919 730 Key:

µs/cm = Micro Siemens per centimeter.

Avg = Average.

Max = Maximum.

Min = Minimum.

NA = Not available.

Std Dev = Standard Deviation.

FPL Turkey Point Annual Post-Uprate Monitoring Report for Units 3 & 4 Uprate Project - August 2014 Section 2 2-20 Table 2.1-2. Statistical Summary of Automated Groundwater Temperature (°C) 2013 2014 Post-Uprate Pre-Uprate Well Jun Jul Aug Sep Oct Nov Dec Jan Feb Mar Apr May Min Max Avg Std Dev Min Max Avg Std Dev TPGW-1S 25.7 25.6 25.5 25.5 25.5 25.6 25.7 25.7 25.7 25.8 25.8 25.8 25.5 25.9 25.7 0.1 25.4 25.8 25.6 0.1 TPGW-1M 25.9 25.9 25.9 25.8 25.8 25.8 25.8 25.8 25.8 25.8 25.9 25.9 25.8 25.9 25.9 0.0 25.9 26.0 26.0 0.0 TPGW-1D 25.9 25.9 25.9 25.9 25.9 25.9 25.9 25.9 25.9 25.9 25.9 25.9 25.9 25.9 25.9 0.0 26.1 26.2 26.1 0.0 TPGW-2S 26.0 25.8 25.7 25.8 25.8 25.9 26.0 26.0 26.1 26.1 26.1 26.4 25.7 26.6 26.0 0.2 25.6 27.5 26.6 0.4 TPGW-2M 26.9 26.8 26.7 26.7 26.6 26.6 26.6 26.6 26.6 26.6 26.6 26.6 26.6 27.0 26.7 0.1 26.7 27.4 27.1 0.1 TPGW-2D 27.1 27.1 27.1 27.1 27.1 27.0 27.0 27.0 27.0 27.0 27.0 27.0 27.0 27.1 27.0 0.0 27.4 27.6 27.4 0.1 TPGW-3S 25.7 25.7 25.7 25.8 25.9 25.9 26.0 26.1 26.1 26.0 25.9 25.8 25.6 26.1 25.9 0.1 25.6 26.2 25.9 0.2 TPGW-3M 25.9 25.9 25.9 25.9 25.9 25.9 25.9 25.9 25.8 25.8 25.8 25.8 25.8 25.9 25.9 0.0 25.9 26.0 25.9 0.0 TPGW-3D 25.7 25.7 25.7 25.7 25.7 25.7 25.7 25.7 25.7 25.7 25.7 25.7 25.7 25.7 25.7 0.0 25.7 25.8 25.8 0.0 TPGW-4S 24.9 24.8 24.7 NA 25.0 25.1 25.2 25.3 25.2 25.1 25.0 25.0 24.7 25.3 25.1 0.2 24.2 25.3 24.8 0.3 TPGW-4M 24.8 24.8 24.8 NA 24.7 24.7 24.7 24.7 24.7 24.7 24.7 24.7 24.7 24.8 24.7 0.1 24.4 24.6 24.5 0.1 TPGW-4D 24.5 24.5 24.5 24.5 24.5 24.5 24.5 24.5 24.5 24.5 24.5 24.5 24.5 24.5 24.5 0.0 24.3 24.5 24.4 0.0 TPGW-5S 23.6 23.5 23.5 23.5 23.5 23.6 23.7 23.7 23.8 23.7 23.6 23.6 23.4 23.8 23.6 0.1 23.3 23.8 23.5 0.2 TPGW-5M 23.7 23.6 23.6 23.6 23.6 23.6 23.6 23.6 23.6 23.6 23.7 23.7 23.6 23.7 23.6 0.0 23.5 23.6 23.5 0.0 TPGW-5D 23.7 23.7 23.7 23.7 23.7 23.7 23.7 23.7 23.7 23.7 23.7 23.7 23.7 23.7 23.7 0.0 23.6 23.7 23.7 0.0 TPGW-6S 23.1 23.1 23.2 23.3 23.4 23.5 23.5 23.5 23.5 23.5 23.5 23.5 23.1 23.5 23.4 0.1 23.0 23.7 23.4 0.2 TPGW-6M 23.6 23.6 23.5 23.5 23.5 23.5 23.5 23.5 23.5 23.5 23.5 23.5 23.5 23.6 23.5 0.0 23.5 23.7 23.6 0.0 TPGW-6D 23.5 23.5 23.5 23.5 23.5 23.5 23.5 23.5 23.5 23.5 23.5 23.5 23.5 23.6 23.5 0.0 23.5 23.6 23.5 0.0 TPGW-7S 23.7 23.7 23.7 23.7 23.8 NA NA 23.8 23.9 23.9 23.8 23.8 23.7 26.3 23.8 0.1 23.6 24.0 23.8 0.1 TPGW-7M 23.8 23.8 23.8 23.8 23.8 23.8 23.7 23.7 23.7 23.8 23.8 23.8 23.7 23.9 23.8 0.0 23.7 23.9 23.8 0.1 TPGW-7D 23.8 23.8 23.8 23.8 23.8 23.8 23.8 23.8 23.8 23.8 23.8 23.8 23.8 23.8 23.8 0.0 23.9 23.9 23.9 0.0 TPGW-8S 23.6 23.5 23.6 23.7 23.8 23.9 23.9 23.9 23.8 23.6 23.5 23.5 23.5 24.0 23.7 0.2 23.3 24.1 23.7 0.3 TPGW-8M 23.7 NA 23.6 23.6 23.6 23.6 23.6 23.6 23.6 23.6 23.6 23.7 23.6 23.7 23.6 0.0 23.6 23.8 23.7 0.1 TPGW-8D 23.7 23.7 23.7 23.7 23.7 23.7 23.7 23.7 23.7 23.7 23.7 23.7 23.6 23.9 23.7 0.0 23.5 23.8 23.7 0.0 TPGW-9S 24.4 24.4 24.5 24.7 24.9 25.0 25.0 24.9 24.8 24.5 24.3 24.3 24.2 25.1 24.6 0.3 24.2 25.3 24.7 0.4 TPGW-9M 23.9 23.8 23.8 23.8 23.8 23.8 23.8 23.9 23.9 23.9 23.9 23.8 23.8 23.9 23.8 0.0 23.6 24.2 23.9 0.2 TPGW-9D 24.0 24.0 24.0 24.0 24.0 24.0 24.0 24.0 24.0 24.0 24.0 24.0 23.9 24.0 24.0 0.0 24.0 24.1 24.0 0.0 TPGW-10S 25.8 25.9 25.9 26.0 26.2 26.3 26.4 26.4 26.4 26.3 26.2 26.1 25.8 26.5 26.2 0.2 25.5 26.6 26.1 0.3 TPGW-10M 25.9 25.9 25.9 25.9 25.9 25.9 25.9 25.9 25.9 25.9 25.9 25.9 25.9 26.0 25.9 0.0 25.8 25.9 25.8 0.0 TPGW-10D 25.6 25.6 25.6 25.6 25.6 25.6 25.6 25.6 25.6 25.6 25.6 25.6 25.6 25.7 25.6 0.0 25.7 25.7 25.7 0.0 TPGW-11S 25.2 25.2 25.2 25.3 25.4 25.5 25.6 25.6 25.5 25.4 25.4 25.4 25.1 25.7 25.4 0.1 25.0 25.5 25.3 0.2 TPGW-11M 25.3 25.3 25.3 25.3 25.3 25.3 25.3 25.3 25.3 25.3 25.3 25.3 25.3 25.3 25.3 0.0 25.3 25.4 25.3 0.0 TPGW-11D 25.3 25.3 25.3 25.3 25.3 25.3 25.3 25.3 25.3 25.3 25.3 25.3 25.2 25.3 25.3 0.0 25.3 25.3 25.3 0.0 TPGW-12S 25.9 25.8 25.8 25.9 25.9 25.9 26.0 26.1 26.1 26.1 26.0 25.9 25.8 26.1 26.0 0.1 25.8 26.3 26.0 0.1 TPGW-12M 26.0 26.0 26.0 26.0 26.0 26.0 26.0 26.0 26.0 26.0 26.0 25.9 25.9 26.0 26.0 0.0 26.0 26.2 26.1 0.0 TPGW-12D 26.0 26.0 26.0 26.0 26.0 26.0 26.0 26.0 26.0 26.0 26.0 26.0 26.0 26.0 26.0 0.0 26.0 26.2 26.1 0.0

FPL Turkey Point Annual Post-Uprate Monitoring Report for Units 3 & 4 Uprate Project - August 2014 Section 2 2-21 Table 2.1-2. Statistical Summary of Automated Groundwater Temperature (°C) 2013 2014 Post-Uprate Pre-Uprate Well Jun Jul Aug Sep Oct Nov Dec Jan Feb Mar Apr May Min Max Avg Std Dev Min Max Avg Std Dev TPGW-13S 29.5 29.4 29.3 29.3 29.3 29.3 29.4 29.4 29.5 29.5 29.5 29.6 29.3 29.6 29.4 0.1 29.3 30.5 30.0 0.4 TPGW-13M 29.4 29.3 29.3 29.3 29.3 29.2 29.2 29.2 29.2 29.2 29.2 29.2 29.2 29.4 29.3 0.1 29.4 29.6 29.5 0.0 TPGW-13D 29.1 29.1 29.1 28.7 NA 29.1 29.1 29.1 29.0 29.0 29.0 29.0

-16.0 29.1 29.1 0.5 29.4 29.5 29.4 0.0 TPGW-14S 25.8 25.9 26.0 26.0 26.2 26.3 26.4 26.4 26.4 26.3 26.2 26.0 25.7 26.5 26.1 0.2 25.5 26.4 26.0 0.3 TPGW-14M 26.2 26.2 26.2 26.2 26.2 26.2 26.2 26.2 26.2 26.2 26.2 26.2 26.2 26.3 26.2 0.0 26.1 26.2 26.2 0.0 TPGW-14D 26.3 26.3 26.4 26.4 26.3 26.3 26.3 26.4 26.4 26.4 26.4 26.4 26.3 26.4 26.4 0.0 26.3 26.4 26.4 0.0 Key:

°C = Degrees Celsius.

Avg = Average.

Max = Maximum.

Min = Minimum.

NA = Not available.

Std Dev = Standard Deviation.

FPL Turkey Point Annual Post-Uprate Monitoring Report for Units 3 & 4 Uprate Project - August 2014 Section 2 2-22 Table 2.1-3. Statistical Summary of Automated Groundwater Salinity (PSS-78)

Post-Uprate Pre-Uprate Well Min Max Avg Std Dev Min Max Avg Std Dev TPGW-1S 25.5 41.4 33.4 4.2 31.7 44.1 38.3 2.5 TPGW-1M 49.4 50.5 50.0 0.3 46.1 53.1 49.5 0.9 TPGW-1D 48.6 50.2 49.4 0.4 48.4 50.8 49.7 0.4 TPGW-2S 45.2 50.4 46.9 0.8 47.5 54.6 51.4 1.4 TPGW-2M 51.7 53.9 52.7 0.4 51.3 54.8 53.1 0.6 TPGW-2D 52.4 54.6 53.2 0.5 50.5 54.6 53.3 0.4 TPGW-3S 36.8 45.3 43.1 1.6 41.8 45.2 43.6 0.4 TPGW-3M 46.0 47.8 47.1 0.4 46.2 49.0 47.8 0.4 TPGW-3D 47.1 48.8 48.0 0.3 46.1 48.8 47.8 0.6 TPGW-4S 0.6 2.8 1.1 0.4 0.6 2.1 1.2 0.2 TPGW-4M 24.6 25.8 25.1 0.4 23.1 25.0 24.2 0.3 TPGW-4D 27.3 28.5 28.0 0.3 26.9 28.8 28.0 0.4 TPGW-5S 0.3 0.6 0.4 0.1 0.0 1.0 0.7 0.1 TPGW-5M 20.3 20.9 20.7 0.2 18.6 20.5 19.5 0.5 TPGW-5D 21.6 22.1 21.9 0.1 19.7 21.7 21.1 0.4 TPGW-6S 0.5 0.6 0.6 0.0 0.5 0.6 0.6 0.0 TPGW-6M 13.7 14.0 13.8 0.1 13.2 14.2 13.8 0.2 TPGW-6D 14.0 14.5 14.4 0.1 13.8 15.2 14.5 0.2 TPGW-7S 0.2 0.3 0.3 0.0 0.2 0.4 0.3 0.0 TPGW-7M 0.3 0.3 0.3 0.0 0.3 0.4 0.3 0.0 TPGW-7D 0.3 2.3 1.0 0.7 0.2 0.3 0.3 0.0 TPGW-8S 0.8 1.2 1.0 0.1 1.1 2.0 1.5 0.2 TPGW-8M 0.3 0.3 0.3 0.0 0.3 0.3 0.3 0.0 TPGW-8D 0.1 0.3 0.3 0.0 0.1 0.4 0.3 0.0 TPGW-9S 0.3 0.3 0.3 0.0 0.0 0.3 0.3 0.0 TPGW-9M 0.3 0.3 0.3 0.0 0.3 0.4 0.3 0.0 TPGW-9D 0.3 0.3 0.3 0.0 0.3 0.3 0.3 0.0 TPGW-10S 34.8 36.7 35.5 0.3 33.3 35.7 34.4 0.7 TPGW-10M 36.7 37.9 37.3 0.3 36.0 37.7 36.8 0.4 TPGW-10D 43.6 46.3 45.4 0.5 36.2 38.1 37.1 0.4 TPGW-11S 36.6 38.3 37.3 0.4 35.7 37.8 36.7 0.6 TPGW-11M 38.1 40.2 38.9 0.5 37.0 39.1 38.0 0.5 TPGW-11D 41.6 43.6 42.4 0.5 37.2 40.3 39.3 0.4 TPGW-12S 25.2 31.4 29.1 0.6 25.0 30.0 26.9 0.7 TPGW-12M 38.6 45.2 42.8 1.7 39.6 45.1 43.7 0.9 TPGW-12D 43.7 45.3 44.4 0.3 43.2 44.8 44.0 0.3

FPL Turkey Point Annual Post-Uprate Monitoring Report for Units 3 & 4 Uprate Project - August 2014 Section 2 2-23 Table 2.1-3. Statistical Summary of Automated Groundwater Salinity (PSS-78)

Post-Uprate Pre-Uprate Well Min Max Avg Std Dev Min Max Avg Std Dev TPGW-13S 58.2 61.6 59.5 0.8 58.5 62.9 60.6 1.0 TPGW-13M 54.9 58.9 55.9 0.5 56.3 59.8 57.7 0.9 TPGW-13D 55.0 59.1 57.2 0.7 57.3 60.9 59.1 0.7 TPGW-14S 38.3 39.5 38.9 0.3 38.5 40.8 39.6 0.6 TPGW-14M 41.6 44.1 42.7 0.4 42.3 46.2 43.7 0.8 TPGW-14D 51.1 52.4 51.7 0.3 50.7 53.5 51.9 0.6 Key:

Avg = Average.

Max = Maximum.

Min = Minimum.

Std Dev = Standard Deviation.

FPL Turkey Point Annual Post-Uprate Monitoring Report for Units 3 & 4 Uprate Project - August 2014 Section 2 2-24 Table 2.2-1. Probe Types/Automated Measurements at Surface Water Stations for Post-Uprate Monitoring Period Surface Water Site Probe Parameters Measured TPSWC-1T AT200 Water Quality, Stage TPSWC-1B AT100 Water Quality TPSWC-2T AT200 Water Quality, Stage TPSWC-2B AT100 Water Quality TPSWC-3T AT200 Water Quality, Stage TPSWC-3B AT100 Water Quality TPSWC-4T AT200 Water Quality, Stage TPSWC-4B AT100 Water Quality TPSWC-5T AT200 Water Quality, Stage TPSWC-5B AT100 Water Quality TPSWID-1T AT200 Water Quality, Stage TPSWID-1B AT100 Water Quality TPSWID-2T AT200 Water Quality, Stage TPSWID-3T AT100 Water Quality TPSWID-3B AT200 Water Quality, Stage TPSWCCS-1T AT200 Water Quality, Stage TPSWCCS-2T AT200 Water Quality, Stage TPSWCCS-3T AT200 Water Quality, Stage TPSWCCS-4T AT200 Water Quality, Stage TPSWCCS-5T AT200 Water Quality, Stage TPSWCCS-6T AT200 Water Quality, Stage TPBBSW-3B AT200 Water Quality, Stage TPBBSW-4B AT100 Water Quality TPBBSW-5B AT100 Water Quality TPBBSW-10B AT200 Water Quality, Stage TPBBSW-14B AT200 Water Quality, Stage Note:

Pre-Uprate station probes TPBBSW-1B, TPBBSW-2B, TPSWCCS-4B, TPSWCCS-5B, and TPSWCCS-6B are not shown since they were eliminated for the Post-Uprate monitoring.

Key:

AT - Aqua TROLL.

B - Bottom.

LT - Level TROLL.

T - Top.

FPL Turkey Point Annual Post-Uprate Monitoring Report for Units 3 & 4 Uprate Project - August 2014 Section 2 2-25 Table 2.2-2. Statistical Summary of Automated Surface Water Specific Conductance (µS/cm)

Well 2013 2014 Post-Uprate Pre-Uprate Jun Jul Aug Sep Oct Nov Dec Jan Feb Mar Apr May Min Max Avg Std Dev Min Max Avg Std Dev TPBBSW-3B 53150 51154 51982 48521 43861 43577 45257 44408 50470 53640 57614 58836 35166 60557 50244 5527 28789 63371 49218 7445 TPBBSW-4B 52832 NA 50868 51220 50044 47911 47979 48985 50050 51881 56384 58224 39614 59330 51479 3452 36028 61649 51129 6361 TPBBSW-5B 48304 47148 45880 48113 48211 46820 45653 47433 48232 49206 53290 57686 40553 60277 48962 3671 32263 64177 49179 7431 TPBBSW-10B 51363 48222 48609 41957 36042 38377 37433 40049 44732 49396 56455 61453 22315 63186 46174 8566 18922 64623 47772 10258 TPBBSW-14B 48640 48092 45786 46241 47742 42631 45778 44621 48657 52212 55969 58905 37975 60196 48753 4741 35635 49933 42282 3686 TPSWC-1T 388 445 650 527 483 673 703 676 691 850 1118 1619 333 1939 733 334 315 3574 813 445 TPSWC-1B 764 711 809 787 733 895 647 916 954 971 1121 1407 562 1649 891 219 387 3158 993 562 TPSWC-2T 592 586 511 571 579 862 689 683 783 978 1740 6555 393 9530 1258 1769 256 6194 1281 1317 TPSWC-2B 952 840 715 933 1002 1237 1150 790 807 1044 1986 8828 444 11585 1690 2266 267 9507 1522 1756 TPSWC-3T 594 630 498 588 749 1378 713 809 1061 1605 3247 6963 377 9498 1560 1865 265 5864 1440 1260 TPSWC-3B 3361 2299 2028 2124 3047 3728 3885 3031 3115 3082 5149 17445 1335 18295 4419 4142 265 22776 3553 5498 TPSWC-4T 39424 32492 31131 35865 44809 34667 26788 26092 18401 17734 26948 58883 15508 62425 32271 12907 378 62601 30178 19440 TPSWC-4B 43774 34951 35021 39177 31219 42239 30746 29103 16739 17706 28219 59245 6351 66755 34250 13150 388 63843 35842 19796 TPSWC-5T 51015 48124 48105 50335 48906 46429 47597 48816 49975 52166 55285 58462 40486 59524 50457 3694 27741 61200 50395 6594 TPSWC-5B 54610 53293 55156 50645 48431 46400 45080 48703 49367 51551 54597 56934 42690 59354 51296 3769 43281 71282 57572 4438 TPSWCCS-1B 78187 83032 83049 85815 89202 93389 93156 97288 102182 108457 117225 118451 72545 121860 95531 13089 54595 88321 75307 7906 TPSWCCS-2B 77366 81440 82142 85770 88842 92632 91941 96670 101899 109417 117333 119002 71802 122533 95135 13580 64216 87632 81273 3619 TPSWCCS-3B 76447 80998 80340 82861 84994 90438 90513 89712 91944 100496 109999 117386 71469 123743 91099 12063 53565 88238 75627 6884 TPSWCCS-4T 76883 80806 79428 83627 89089 93915 91611 95228 100060 95094 116521 118056 66629 120953 93109 13601 55754 90575 79288 6544 TPSWCCS-5T 74402 79098 77156 82986 86102 90271 87738 87113 88185 96678 99844 111813 72146 118728 88352 10806 54602 89303 78069 7024 TPSWCCS-7B 78082 82279 83288 85972 89183 93681 93820 96763 101357 106114 109250 111010 43516 120329 92221 10647 53511 85289 70798 5508 TPSWID-1T 3580 4030 3427 3384 3256 3840 3453 3809 4152 7587 7206 8389 2101 45621 12200 10291 2101 45621 12200 10291 TPSWID-1B 12153 9139 3805 5289 5828 4019 3821 5493 7917 16152 14297 19343 1847 21884 9014 5271 2109 48037 16595 12223 TPSWID-2T 3382 3811 2473 3113 2901 3267 2958 3665 3590 3435 3867 4787 2069 6307 3444 641 1441 55392 9361 11190 TPSWID-2B 13807 10562 7621 6227 4799 3460 3684 4009 5605 5875 5992 8166 2824 20016 6788 3270 2146 68416 28356 23449 TPSWID-3T 3413 3254 2454 2476 4120 6690 2964 3198 3199 3250 3575 6112 2309 11831 3731 1603 1177 62140 7868 12473 TPSWID-3B 3408 3263 2497 2621 5103 8375 3353 3243 3230 3285 4073 18249 2253 35500 5062 4926 1211 66206 12920 19165 Key:

µS/cm = Micro Siemens per centimeter.

Avg = Average.

Max = Maximum.

Min = Minimum.

NA = Not available.

Std Dev = Standard Deviation.

FPL Turkey Point Annual Post-Uprate Monitoring Report for Units 3 & 4 Uprate Project - August 2014 Section 2 2-26 Table 2.2-3. Statistical Summary of Automated Surface Water Temperature (°C)

Well 2013 2014 Post-Uprate Pre-Uprate Jun Jul Aug Sep Oct Nov Dec Jan Feb Mar Apr May Min Max Avg Std Dev Min Max Avg Std Dev TPBBSW-3B 29.6 29.1 30.0 29.5 27.6 24.8 24.0 20.5 24.7 24.2 26.2 27.5 15.4 33.3 26.5 3.3 9.5 34.8 25.1 4.4 TPBBSW-4B 28.5 NA 30.0 29.5 27.9 24.8 24.0 20.9 24.8 24.6 26.3 27.5 17.5 31.4 26.0 2.9 15.9 33.7 26.2 3.7 TPBBSW-5B 30.0 29.6 30.4 29.9 28.1 25.1 24.3 21.3 25.0 24.8 26.6 27.8 17.1 32.8 26.8 3.1 15.8 34.5 26.4 3.7 TPBBSW-10B 29.8 29.6 30.2 29.9 27.9 24.6 24.0 20.4 24.9 24.3 26.3 27.5 15.5 33.7 26.6 3.3 14.9 35.2 26.2 3.8 TPBBSW-14B 29.7 29.4 30.1 29.6 27.9 24.8 24.0 20.9 24.9 24.6 26.4 27.5 17.6 32.3 26.7 3.0 16.6 33.9 26.4 3.7 TPSWC-1T 29.5 29.3 29.9 28.9 27.6 25.1 24.1 21.4 24.8 25.4 27.4 28.8 18.0 31.6 26.9 2.8 14.5 33.7 25.7 4.0 TPSWC-1B 27.0 27.7 28.9 27.9 27.0 24.9 23.6 21.0 22.7 24.6 26.0 27.6 19.1 29.6 25.7 2.4 14.7 30.6 24.6 3.9 TPSWC-2T 29.7 29.8 30.0 29.1 27.8 25.0 24.2 21.4 25.0 25.2 27.3 28.9 17.8 32.0 27.0 2.9 14.1 34.8 25.4 4.0 TPSWC-2B 28.4 28.6 29.2 28.4 27.3 24.8 23.5 20.7 23.6 24.7 26.8 29.9 18.5 31.8 26.4 2.9 14.0 31.8 24.7 4.1 TPSWC-3T 30.3 30.1 30.5 29.7 28.2 25.1 24.1 21.4 24.8 25.4 27.4 28.5 18.3 33.1 27.2 3.1 15.1 33.6 25.9 4.0 TPSWC-3B 29.7 29.7 29.9 29.1 27.5 24.8 23.5 20.5 23.3 25.0 27.5 29.8 18.2 31.9 26.7 3.3 15.0 32.2 25.5 4.3 TPSWC-4T 27.9 28.6 28.7 29.8 30.0 24.9 26.0 22.8 25.4 25.6 27.9 29.3 19.2 32.9 27.3 2.5 18.2 34.4 26.8 3.0 TPSWC-4B 27.8 28.6 28.7 30.1 29.2 26.2 25.9 22.8 25.5 25.8 27.9 29.3 19.3 32.0 27.3 2.4 17.4 34.5 27.0 3.0 TPSWC-5T 30.0 29.8 30.5 30.0 28.6 25.3 24.6 21.6 25.1 25.4 26.8 28.3 18.8 33.4 27.2 2.9 13.8 34.5 26.3 4.2 TPSWC-5B 27.8 30.0 30.6 30.2 28.8 25.8 24.7 21.6 24.1 25.1 26.1 27.9 19.2 33.1 26.9 2.9 16.4 34.9 27.5 3.8 TPSWCCS-1B 41.7 41.1 42.0 41.6 40.7 37.5 36.5 34.3 39.5 37.7 37.7 41.7 27.8 44.7 39.2 3.0 18.0 43.8 34.4 4.2 TPSWCCS-2B 35.3 35.4 36.5 36.5 34.4 31.2 31.4 29.3 33.5 31.2 32.2 35.3 21.4 42.3 33.5 3.4 14.5 38.2 29.8 4.1 TPSWCCS-3B 34.6 34.6 35.5 35.1 33.0 29.8 29.9 27.8 32.1 30.9 32.8 33.8 20.0 39.4 32.5 3.1 14.8 39.8 29.3 4.2 TPSWCCS-4T 33.1 33.0 33.9 33.7 31.6 28.4 28.5 26.2 30.4 29.2 30.8 32.4 18.1 38.1 30.9 3.2 12.4 37.8 27.9 4.2 TPSWCCS-5T 33.0 32.9 33.9 33.6 31.5 28.3 28.4 26.0 30.2 29.1 30.8 32.3 18.2 37.2 30.8 3.1 12.8 37.0 27.3 4.0 TPSWCCS-7B 37.8 37.5 38.5 38.4 36.7 33.3 33.2 31.4 35.7 31.2 30.1 36.0 16.3 43.1 35.0 4.0 15.7 42.6 31.7 4.2 TPSWID-1T 30.4 30.2 31.1 29.8 28.3 25.5 24.8 22.8 25.8 26.0 27.7 28.6 16.8 36.3 26.7 3.6 16.8 36.3 26.7 3.6 TPSWID-1B 30.3 29.9 30.8 30.1 28.8 25.2 24.4 23.0 25.9 27.7 28.2 29.4 20.2 31.7 27.8 2.6 16.8 33.9 26.9 3.2 TPSWID-2T 29.6 29.6 30.2 29.6 28.5 25.8 25.2 23.4 25.8 25.7 27.2 28.5 21.1 32.2 27.4 2.3 18.8 33.6 26.7 3.1 TPSWID-2B 27.6 27.4 27.4 27.6 27.8 25.6 25.1 23.1 25.6 26.2 27.1 28.0 21.2 28.9 26.6 1.5 18.8 32.5 27.5 2.6 TPSWID-3T 29.4 29.3 30.1 29.5 28.6 25.8 24.8 23.1 25.6 25.6 27.0 28.3 20.6 31.8 27.3 2.3 18.3 34.4 26.7 3.3 TPSWID-3B 28.6 28.5 29.1 28.6 28.4 25.8 24.5 22.7 25.2 25.2 26.4 28.2 20.6 30.0 26.8 2.2 18.1 33.8 26.3 3.0 Key:

°C = Degrees Celsius.

Avg = Average.

Max = Maximum.

Min = Minimum.

Std Dev = Standard Deviation.

FPL Turkey Point Annual Post-Uprate Monitoring Report for Units 3 & 4 Uprate Project - August 2014 Section 2 2-27 Table 2.2-4. Statistical Summary of Automated Surface Water Salinity (PSS-78)

Well Post-Uprate Pre-Uprate Min Max Avg Std Dev Min Max Avg Std Dev TPBBSW-3B 22.5 41.4 33.5 4.2 18.0 43.7 32.7 5.6 TPBBSW-4B 25.6 40.4 34.4 2.6 23.1 42.3 34.2 4.8 TPBBSW-5B 26.4 41.2 32.5 2.8 20.4 44.3 32.7 5.6 TPBBSW-10B 13.6 43.5 30.5 6.3 11.4 44.5 31.8 7.6 TPBBSW-14B 24.4 41.1 32.4 3.6 22.8 31.9 27.6 2.7 TPSWC-1T 0.2 1.0 0.4 0.2 0.2 1.9 0.4 0.2 TPSWC-1B 0.3 0.8 0.4 0.1 0.2 1.7 0.5 0.3 TPSWC-2T 0.2 5.4 0.7 1.0 0.1 3.4 0.7 0.7 TPSWC-2B 0.2 6.7 0.9 1.3 0.1 5.4 0.8 1.0 TPSWC-3T 0.2 5.4 0.8 1.1 0.1 3.2 0.7 0.7 TPSWC-3B 0.7 11.0 2.4 2.5 0.1 14.0 2.0 3.3 TPSWC-4T 9.2 42.9 20.7 9.2 0.2 43.1 19.6 13.2 TPSWC-4B 3.5 46.2 22.1 9.3 0.2 43.7 23.6 13.5 TPSWC-5T 26.2 40.6 33.7 2.8 17.5 42.0 33.6 4.9 TPSWC-5B 27.8 40.4 34.3 2.9 28.2 49.1 39.1 3.5 TPSWCCS-1B 51.1 94.9 70.9 11.7 36.9 64.3 53.4 6.4 TPSWCCS-2B 50.4 95.5 70.4 12.0 44.2 63.7 58.1 3.1 TPSWCCS-3B 50.2 96.6 66.8 10.6 36.7 64.2 53.5 5.7 TPSWCCS-4T 46.3 93.8 68.5 12.0 37.7 65.8 56.4 5.4 TPSWCCS-5T 50.7 91.8 64.3 9.4 39.2 64.7 55.4 5.7 TPSWCCS-7B 28.6 93.2 67.8 9.3 36.0 61.5 49.6 4.4 TPSWID-1T 1.1 30.1 7.3 6.6 1.1 30.1 7.3 6.6 TPSWID-1B 0.9 13.4 5.2 3.3 1.1 31.9 10.2 8.0 TPSWID-2T 1.1 3.5 1.8 0.4 0.7 37.4 5.6 7.3 TPSWID-2B 1.5 12.1 3.8 2.0 1.1 47.6 18.6 16.4 TPSWID-3T 1.2 6.9 2.0 0.9 0.6 42.7 4.8 8.4 TPSWID-3B 1.2 22.7 2.8 3.1 0.6 45.9 8.2 13.3 Key:

Avg = Average.

Max = Maximum.

Min = Minimum.

PSS-78 = Practical Salinity Scale of 1978.

Std Dev = Standard Deviation.

FPL Turkey Point Annual Post-Uprate Monitoring Report for Units 3 & 4 Uprate Project - August 2014 Section 2 2-28 Table 2.4-1. Parameters Collected at Hourly Intervals Reported by the Meteorological Station at TPM-1 Parameter Units Accuracy Resolution Rainfall - Amount inches Better than 5%,

weather dependent 0.001 Relative Humidity

+/- 3 0.1 Temperature

°Celsius

+/- 0.3

+/- 0.1 Barometric Pressure mmHg 0.5 0.5 Wind Speed-Average mph 1 ft/sec 0.3 ft/sec Wind Speed-Gusts and Lull mph 1 ft/sec 0.3 ft/sec Wind Direction degrees

+/- 3 1

Light Level

µmol m-2 s-1 5-10 µA/100 µmol m-2 s-1 NA Hail Hits 1

1 Key:

ft/sec = Feet per second.

mmHg = Millimeters of mercury.

mph = Miles per hour.

NA = Not applicable.

mol m-2 s = Micromoles per meter square per second.

FPL Turkey Point Annual Post-Uprate Monitoring Report for Units 3 & 4 Uprate Project - August 2014 Section 2 2-29 Table 2.4-2. Rainfall Recorded at the Meteorological Station TPM-1 (June 2013 -

May 2014)

Month Day Year Rain (in) 6 2

2013 0.06 6

3 2013 0.03 6

4 2013 0.01 6

6 2013 0.16 6

7 2013 0.08 6

8 2013 0.02 6

9 2013 0.14 6

10 2013 0.06 6

27 2013 0.03 6

30 2013 0.01 7

1 2013 0.04 7

2 2013 0.08 7

3 2013 0.05 7

4 2013 0.08 7

5 2013 0.19 7

10 2013 0.13 7

11 2013 0.05 7

12 2013 0.03 7

13 2013 0.09 7

14 2013 0.01 7

15 2013 0.02 7

16 2013 0.01 7

17 2013 0.79 7

18 2013 0.25 7

24 2013 0.02 7

27 2013 0.01 7

29 2013 0.56 7

31 2013 0.01 8

2 2013 0.15 8

3 2013 0.27 8

5 2013 0.03 8

6 2013 0.06 8

9 2013 0.02 8

14 2013 0.18 8

15 2013 0.12 8

17 2013 0.02 8

18 2013 0.01 Month Day Year Rain (in) 8 19 2013 0.03 8

20 2013 0.16 8

22 2013 0.03 8

27 2013 0.02 8

28 2013 0.17 8

31 2013 0.02 9

2 2013 0.04 9

4 2013 0.01 9

5 2013 0.14 9

7 2013 0.50 9

10 2013 0.02 9

11 2013 0.01 9

12 2013 0.04 9

14 2013 0.01 9

15 2013 0.26 9

16 2013 0.17 9

17 2013 0.12 9

19 2013 0.20 9

20 2013 0.27 9

23 2013 0.30 9

25 2013 0.01 9

28 2013 0.17 10 1

2013 0.02 10 8

2013 0.18 10 10 2013 0.01 10 16 2013 0.01 10 19 2013 0.33 10 21 2013 0.01 10 22 2013 0.01 10 23 2013 0.36 10 24 2013 0.40 10 29 2013 0.01 10 31 2013 0.01 11 4

2013 0.12 11 9

2013 0.13 11 10 2013 0.01 11 13 2013 0.16

FPL Turkey Point Annual Post-Uprate Monitoring Report for Units 3 & 4 Uprate Project - August 2014 Section 2 2-30 Table 2.4-2. Rainfall Recorded at the Meteorological Station TPM-1 (June 2013 -

May 2014)

Month Day Year Rain (in) 11 19 2013 0.09 11 21 2013 0.01 11 22 2013 0.19 11 24 2013 0.37 11 26 2013 0.06 11 27 2013 0.52 11 30 2013 0.47 12 1

2013 0.001 12 3

2013 0.001 12 4

2013 0.003 12 5

2013 0.001 12 8

2013 0.004 12 13 2013 0.001 12 15 2013 0.005 12 16 2013 0.025 12 17 2013 0.001 12 20 2013 0.001 12 25 2013 0.008 12 26 2013 0.287 12 29 2013 0.003 1

1 2014 0.001 1

4 2014 0.014 1

5 2014 0.007 1

6 2014 0.148 1

7 2014 0.007 1

8 2014 0.082 1

9 2014 0.032 1

12 2014 0.007 1

15 2014 0.006 1

21 2014 0.043 1

29 2014 0.008 1

30 2014 0.278 2

7 2014 0.002 2

8 2014 0.002 2

12 2014 0.287 2

13 2014 0.021 2

15 2014 0.001 Month Day Year Rain (in) 2 27 2014 0.139 2

28 2014 0.053 3

5 2014 0.044 3

6 2014 0.250 3

9 2014 0.001 3

14 2014 0.002 3

15 2014 0.001 3

17 2014 0.003 3

18 2014 0.051 3

20 2014 0.001 3

22 2014 0.045 3

23 2014 0.003 3

24 2014 0.001 3

25 2014 0.380 3

28 2014 0.001 3

29 2014 0.193 3

30 2014 0.016 3

31 2014 0.001 4

4 2014 0.002 4

7 2014 0.002 4

8 2014 0.044 4

10 2014 0.001 4

11 2014 0.001 4

13 2014 0.002 4

17 2014 0.079 4

18 2014 0.007 4

20 2014 0.002 4

21 2014 0.001 4

22 2014 0.006 4

23 2014 0.005 4

24 2014 0.001 4

25 2014 0.004 4

26 2014 0.005 4

27 2014 0.008 4

28 2014 0.005 4

29 2014 0.005 4

30 2014 0.002

FPL Turkey Point Annual Post-Uprate Monitoring Report for Units 3 & 4 Uprate Project - August 2014 Section 2 2-31 Table 2.4-2. Rainfall Recorded at the Meteorological Station TPM-1 (June 2013 -

May 2014)

Month Day Year Rain (in) 5 2

2014 0.001 5

3 2014 0.097 5

4 2014 0.005 5

5 2014 0.009 5

6 2014 0.003 5

7 2014 0.004 5

8 2014 0.002 5

11 2014 0.002 5

12 2014 0.006 5

13 2014 0.022 5

14 2014 0.128 5

15 2014 0.016 5

16 2014 0.002 5

17 2014 0.001 5

18 2014 0.001 5

21 2014 0.003 5

22 2014 0.002 5

27 2014 0.005 5

29 2014 0.004 Key:

in = inches.

TPM = Turkey Point Meteorological.

FPL Turkey Point Annual Post-Uprate Monitoring Report for Units 3 & 4 Uprate Project - August 2014 Section 2 2-32 Table 2.4-3. Comparison of Post-and Pre-Uprate Monthly Rainfall Totals TPM-1 Post-Uprate Pre-Uprate June 2013 - May 2014 June 2010 - May 2011 Month

  1. of Rain Days Amount (inches)
  1. of Rain Days Greater than 1 Inch Month
  1. of Rain Days Amount (inches)
  1. of Rain Days Greater than 1 Inch Jun-131 10 0.6 NA Jun-102 NA NA NA Jul-13 18 2.41 0

Jul-102 NA NA NA Aug-13 15 1.28 0

Aug-10 20 8.95 3

Sep-13 16 2.25 0

Sep-10 24 13.49 4

Oct-13 11 1.35 0

Oct-10 13 2.32 0

Nov-13 11 2.14 0

Nov-10 12 5.5 1

Dec-13 13 0.34 0

Dec-10 6

0.54 0

Jan-14 12 0.63 0

Jan-11 8

3.53 1

Feb-14 7

0.5 0

Feb-11 6

0.24 0

Mar-14 17 0.99 0

Mar-11 11 1.64 0

Apr-14 19 0.18 0

Apr-11 8

1.85 1

May-14 19 0.31 0

May-11 27 2.4 0

TOTALS (Aug-May) 12.39 0

40.46 Notes:

1 Rainfall data was missing from 6/11/2013 through 6/26/2013 as a result of the unit repair.

2 Unit became operational on 7/26/10.

Key:

NA - Not available since the system was not yet in operation or was under repair.

FPL Turkey Point Annual Post-Uprate Monitoring Report for Units 3 & 4 Uprate Project - August 2014 Section 2 2-33 Table 2.4-4. Monthly Rainfall in and around the CCS Month NEXRAD1 (inches)

TPM-1 (inches)

LU-South (inches)

S-20 Gauge (inches)

Homestead Air Force (inches)

Month NEXRAD1 (inches)

TPM-1 (inches)

LU-South (inches)

S-20 Gauge (inches)

Homestead Air Force (inches)

Aug-10 NA 8.95 NA 8.76 6.94 Jul-12 5.14 8.74 9.35 13.17 11.38 Sep-10 13.15 13.49 NA 15.70 11.67 Aug-12 6.94 12.53 9.21 9.27 15.86 Oct-10 2.40 2.32 NA 2.77 2.62 Sep-12 5.00 6.98 8.95 12.18 9.43 Nov-10 4.39 5.50 6.12 3.11 3.37 Oct-12 2.44 4.87 3.63 4.44 5.88 Dec-10 0.69 0.54 1.00 0.72 0.47 Nov-12 0.27 1.32 0.69 0.81 1.65 Jan-11 3.32 3.53 2.81 4.57 4.03 Dec-12 0.32 0.64 0.46 0.55 0.63 Feb-11 0.10 0.24 0.11 0.08 0.12 Jan-13 0.18 0.31 0.52 0.41 0.26 Mar-11 1.24 1.64 1.13 1.19 1.23 Feb-13 0.85 1.23 1.42 1.15 0.96 Apr-11 1.65 1.85 0.06 0.92 1.09 Mar-13 0.93 1.26 1.06 1.25 2.16 May-11 1.13 2.40 0.37 1.23 1.12 Apr-13 3.89 3.45 4.84 6.38 5.92 Jun-11 1.35 2.93 0.42 2.17 2.67 May-13 8.59 3.08 7.68 14.54 15.60 Jul-11 7.68 10.64 8.47 5.87 5.59 Jun-13 3.15 0.6 4.05 5.06 6.63 Aug-11 6.52 9.24 6.32 3.04 9.55 Jul-13 8.31 2.41 8.61 8.60 10.27 Sep-11 6.19 6.93 4.95 8.6 4.66 Aug-13 4.47 1.28 6.40 3.07 1.88 Oct-11 8.84 13.25 14.5 7.78 12.27 Sep-13 4.41 2.25 5.74 4.68 6.31 Nov-11 0.23 0.32 0.61 1.12 0.74 Oct-13 1.28 1.35 2.47 1.32 1.09 Dec-11 0.33 0.56 1.32 0.43 0.28 Nov-13 5.42 2.14 5.71 4.81 3.67 Jan-12 0.45 1.45 0.92 0.30 0.06 Dec-13 0.78 0.341 2.58 2.97 2.50 Feb-12 5.60 5.94 5.42 5.82 6.37 Jan-14 1.47 0.633 1.87 3.00 3.28 Mar-12 0.45 0.98 1.25 2.18 2.57 Feb-14 1.67 0.505 1.82 2.58 2.25 Apr-12 8.45 12.49 11.69 7.07 10.64 Mar-14 1.18 0.993 1.42 1.75 1.65 May-12 7.26 9.41 4.39 9.90 9.85 Apr-14 0.40 0.182 0.99 0.31 0.35 Jun-12 5.21 8.90 NA 6

10.73 May-14 1.30 0.313 1.75 2.00 1.90 Notes:

1 NEXRAD data provided by SFWMD.

2 Data were missing from 6/11/2013 through 6/26/2013 as a result of unit repair.

Key:

LU = Land Utilization.

NEXRAD = Next generation radar.

TPM = Turkey Point Meteorological.

FPL Turkey Point Annual Post-Uprate Monitoring Report for Units 3 & 4 Uprate Project - August 2014 Section 2 FIGURES

FPL Turkey Point Annual Post-Uprate Monitoring Report for Units 3 & 4 Uprate Project-August 2014 Typical automated probe and cable.

Figure 2.1-1. Automated Groundwater Stations.

2-35 Section2 Biscayne Bay station.

FPL Turkey Point Annual Post-Uprate Monitoring Report for Units 3 & 4 Uprate Project - August 2014 Section 2 e

~

Cl)

CJ c:

Ill -

CJ

J "C

c:

0

(.)

CJ

!E CJ Cl)

Q.

CJ')

100000 ~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~

90000 80000 70000 60000 50000 40000 30000 20000 10000

,.r-

0 -!--------------------------------------------- 28 27 26 25 24

,__~~~~~~~~~~~~~~___.,_~~~~~~~~~~----.~~~~~~~~---- 23 6/1/10 9/1/10 1211/10 3/1/11 6/1/11 9/1/11 1211/11 3/1112 6/1112 9/1/12 1211112 3/1/13 6/1/13 9/1/13 1211/13 3/1/14 6/1/14 c::::::J Interim Operating Period -- Shallow Intermediate -- Deep Figure 2.1-2. TPGW-1 Specific Conductance and Temperature.

2-36

(.)

~

Cl)...

J -

Ill...

Cl)

Q.

E Cl)

FPL Turkey Point Annual Post-Uprate Monitoring Report for Units 3 & 4 Uprate Project - August 2014 Section 2 100000 90000 E

CJ -

en 80000 2:

Q)

~ -. -JP\\

CJ 70000 c:

n:J 60000 CJ

J "C

50000 c:

0 0

CJ 40000 i;:::

  • i:;

30000 Q) c.

en 20000 10000 0

28 27 0

0 26 -

Q)...

J -

n:J...

Q) 25

c.

E Q)

I-24 1------~------------------------__.,----~------+ 23 611110 911110 1211110 311/11 6/1111 911/11 1211/11 3/1112 611112 911112 1211112 311113 611113 911113 1211113 311/14 611/14 c::::J Interim Operating Period

-- Shallow Intermediate -- Deep Figure 2.1-3. TPGW-2 Specific Conductance and Temperature.

2-37

FPL Turkey Point Annual Post-Uprate Monitoring Report for Units 3 & 4 Uprate Project - August 2014 Section 2 100000 e 90000

(,) -"'

80000 Cl) 70000

(,)

c:

-~

Ill 60000 r--r--

I

(,)

J "C

50000 c:

0 (J

(,)

40000 It=

'(j Cl) 30000 Q.

20000 10000 0

28 27 -

(J 26

~

Cl)...

J -

Ill...

Cl) 25 Q.

E Cl) 24

,__~~~~~~~~~~~~~~___.,_~~~~~~~~~~----.~~~~~~~~---- 23 6/1/10 9/1/10 1211/10 3/1/11 6/1/11 9/1/11 1211/11 3/1112 6/1112 9/1/12 1211112 3/1/13 6/1/13 9/1/13 1211/13 3/1/14 6/1/14 c::::::J Interim Operating Period -- Shallow Intermediate -- Deep Figure 2.1-4. TPGW-3 Specific Conductance and Temperature.

2-38

FPL Turkey Point Annual Post-Uprate Monitoring Report for Units 3 & 4 Uprate Project - August 2014 Section 2 e

(,) -"'

2::

Cl)

(,) c:

Ill -

(,)

J "C c:

0

(.)

(,)

!E

(,)

Cl)

Q.

100000 90000 80000 70000 60000 50000 40000

    • I 30000 20000 10000 0

28 27 26 25 24 23 6/1/10 9/1/10 1211/10 3/1/11 6/1/11 9/1/11 1211/11 3/1112 6/1112 9/1/12 1211112 3/1/13 6/1/13 9/1/13 1211/13 3/1/14 6/1/14 c::::::J Interim Operating Period -- Shallow Intermediate -- Deep Figure 2.1-5. TPGW-4 Specific Conductance and Temperature.

2-39

(.)

~

Cl)...

J -

Ill...

Cl)

Q.

E Cl)

I-

FPL Turkey Point Annual Post-Uprate Monitoring Report for Units 3 & 4 Uprate Project - August 2014 Section 2 100000 e 90000

(,) -"'

80000 2::

Cl) 70000

(,) c:

Ill 60000

(,)

s "C

50000 c:

0 (J

(,)

40000

!E 30000

,~

(,)

Cl) a.

20000 10000 0

28 27 -

(J 26

~

Cl)...

s -

Ill...

Cl) 25

a.

E Cl)

I-24 o--~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~---

23 6/1/10 9/1/10 1211/10 3/1/11 6/1/11 9/1/11 1211/11 3/1112 6/1112 9/1/12 1211112 3/1/13 6/1/13 9/1/13 1211/13 3/1/14 6/1/14 c::::::J Interim Operating Period -- Shallow Intermediate -- Deep Figure 2.1-6. TPGW-5 Specific Conductance and Temperature.

2-40

FPL Turkey Point Annual Post-Uprate Monitoring Report for Units 3 & 4 Uprate Project - August 2014 Section 2 100000 e 90000

(,) -"'

80000 2::

Cl) 70000

(,) c:

Ill 60000

(,)

s "C

50000 c:

0 (J

(,)

40000 It=

'(j 30000 Cl) a.

20000 10000 0

28 27 -

(J 26

~

Cl)...

s -

Ill...

Cl) 25

a.

E Cl) 24 1--"""=--~--~-~-~~-~-~~-~-~~-~-~-------.:.--~-~--~---f-23 6/1/10 9/1/10 1211/10 3/1/11 6/1/11 9/1/11 1211/11 3/1112 6/1112 9/1/12 1211112 3/1/13 6/1/13 9/1/13 1211/13 3/1/14 6/1/14 c::::::J Interim Operating Period -- Shallow Intermediate -- Deep Figure 2.1-7. TPGW-6 Specific Conductance and Temperature.

2-41

FPL Turkey Point Annual Post-Uprate Monitoring Report for Units 3 & 4 Uprate Project - August 2014 Section 2 e

!,,) -

Cl).::

Cl)

!,,)

c:

Ill -

!,,)

J "C

c:

0

(.)

!,,)

!E

!,,)

Cl) a.

Cl) 5000 4500 4000 3500 3000 2500 2000 1500 1000 500 0

28 27 26 25 24 23 6/1/10 9/1/10 1211/10 3/1/11 6/1/11 9/1/11 1211/11 3/1112 6/1112 9/1/12 1211112 3/1/13 6/1/13 9/1/13 1211/13 3/1/14 6/1/14 c::::::J Interim Operating Period -- Shallow Intermediate -- Deep Figure 2.1-8. TPGW-7 Specific Conductance and Temperature.

2-42

(.)

~

Cl)...

J -

Ill...

Cl) a.

E Cl)

FPL Turkey Point Annual Post-Uprate Monitoring Report for Units 3 & 4 Uprate Project - August 2014 5000 e

4500

(,) -""

4000 2::

Q) 3500

(,) c:

11' 3000

(,)

J "C

2500 c:

0 0

(,)

2000

!e 1500

(,)

Q) a.

1000 500 r111 11 0

'm 11[ ll[llUI Section 2 27 0

0 26

-~

25

J 1a...

Q) a.

E Q) fo-i--~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~---+- 23 6/ 1/ 10 9/1/10 12/1/10 3/1/11 6/1/11 9/1/11 12/1/11 3/1/12 6/1/12 9/1/12 12/1/12 3/1/13 6/1/13 9/1/13 12/1/13 3/1/14 6/1/14 c::::J Interim Operating Period -- Shallow Intermediate -- Deep Figure 2.1-9. TPGW-8 Specific Conductance and Temperature.

2-43

FPL Turkey Point Annual Post-Uprate Monitoring Report for Units 3 & 4 Uprate Project - August 2014 Section 2 TABLES

FPL Turkey Point Annual Post-Uprate Monitoring Report for Units 3 & 4 Uprate Project - August 2014 Section 2 2-18 Table 2.1-1. Statistical Summary of Automated Groundwater Specific Conductance (S/cm) 2013 2014 Post-Uprate Pre-Uprate Well Jun Jul Aug Sep Oct Nov Dec Jan Feb Mar Apr May Min Max Avg Std Dev Min Max Avg Std Dev TPGW-1S 58971 54288 46582 40260 41060 48528 51298 51568 51620 53262 51056 52173 39352 60685 50075 5600 47861 64171 56648 3331 TPGW-1M 71887 71961 71864 71762 71828 71397 71235 71477 71503 71332 71108 71250 70767 72165 71554 332 66640 75369 70952 1162 TPGW-1D 71396 71326 71279 71252 71102 70457 70430 70630 70702 70628 70024 70467 69853 71737 70817 480 69525 72580 71189 536 TPGW-2S 68408 67317 66043 67014 67748 67767 67682 67390 67403 67550 68212 69203 65498 72037 67690 989 68360 77088 73321 1631 TPGW-2M 75344 74854 74787 75345 75261 74745 74864 74341 74163 74268 74612 74901 73666 76234 74807 451 73143 77386 75263 773 TPGW-2D 76417 75732 74835 75444 75995 75484 75574 75514 75429 75301 74739 74795 74502 77182 75442 563 72128 77116 75491 476 TPGW-3S 64058 63567 64082 65116 65315 63875 62868 61476 60304 61449 60074 61994 54694 65637 62882 2026 61114 65491 63481 577 TPGW-3M 68387 68073 68120 68582 68484 67767 67692 67506 67325 67233 67671 67334 66557 68750 67858 493 66779 70236 68803 493 TPGW-3D 69585 69109 69211 69652 69694 69167 69149 68783 68605 68729 68769 68636 67967 70029 69101 432 66628 70014 68845 765 TPGW-4S 1538 1559 1769 NA 1854 2006 1859 1746 1966 2654 3135 3516 1251 5085 2159 672 1204 3867 2227 391 TPGW-4M 38751 38773 38844 NA 38637 38501 38511 38583 38577 39192 39809 39428 38149 39885 38886 494 35988 38785 37579 469 TPGW-4D 43230 43358 42977 42357 42636 42899 42882 42999 43017 42878 42513 42285 41934 43504 42838 359 41327 43986 42880 535 TPGW-5S 942 943 922 1003 905 885 863 837 797 790 791 818 692 1173 877 104 724 1947 1291 204 TPGW-5M 32821 32868 32936 32696 32683 32664 32629 32510 32475 32550 32267 32084 32023 33004 32601 247 29580 32438 30953 657 TPGW-5D 34344 34199 34312 34613 34487 34394 34170 34258 34360 34643 34595 34577 33883 34726 34412 194 31234 34077 33224 596 TPGW-6S 1082 1104 1150 1210 1207 1177 1183 1204 1215 1195 1171 1185 991 1231 1173 44 1044 1258 1147 57 TPGW-6M 22535 22518 22534 22512 22641 22535 22623 22808 22846 22749 22607 22524 22429 22943 22616 124 21669 23108 22603 272 TPGW-6D 23288 23315 23311 23307 23343 23610 23589 23467 23458 23453 23461 23527 22819 23659 23426 118 22537 24697 23641 248 TPGW-7S 529 530 525 526 523 NA NA 542 545 555 563 557 498 573 540 15 421 906 569 36 TPGW-7M 618 637 614 589 589 581 614 615 598 592 602 592 568 670 604 21 567 712 616 34 TPGW-7D 595 596 812 912 1140 1402 1653 2617 3191 3517 3959 4195 526 4323 1993 1335 418 679 592 19 TPGW-8S 2039 1845 1984 1971 2221 2073 1930 2105 1992 2067 2049 2010 1599 2302 2025 124 2067 3681 2878 348 TPGW-8M 634 NA 644 656 652 624 624 634 636 632 620 618 610 658 634 14 627 655 642 7

TPGW-8D 649 638 667 682 683 670 662 665 660 656 656 657 226 706 662 30 237 714 680 19 TPGW-9S 597 592 584 583 597 601 601 613 612 613 615 612 567 618 601 13 60 659 588 59 TPGW-9M 604 618 630 638 635 600 595 554 538 558 583 588 516 644 596 33 605 752 651 21 TPGW-9D 631 638 638 635 632 617 617 615 617 619 627 626 592 670 626 10 627 655 639 8

TPGW-10S 52468 52958 53057 52817 52791 52809 52974 53146 52965 52672 52505 53801 52034 54584 52913 385 50000 53163 51443 869 TPGW-10M 55058 55001 55101 55093 55171 54797 55256 55624 55513 55409 55361 55926 54514 56077 55272 341 53629 55812 54669 485 TPGW-10D 64717 65063 65204 65172 65295 65731 66325 66623 66422 66346 66294 66057 63546 66910 65749 674 53918 56544 55111 559 TPGW-11S 55416 55320 55584 55271 55072 54937 55347 55638 56541 55330 54574 55794 54433 56686 55401 555 53281 56001 54606 734 TPGW-11M 56638 56598 57632 57124 56703 57008 57255 57411 57768 58371 58758 57234 56349 59098 57374 679 54895 57774 56205 616 TPGW-11D 61371 61345 61175 61229 61300 61863 62163 62349 63257 62606 62228 62440 60938 63556 61933 668 55275 59311 58008 576 TPGW-12S 43645 NA 43963 43880 NA NA 43262 43745 43966 44278 44950 45847 38893 47520 44286 877 38736 45533 41280 984 TPGW-12M 64219 64766 65118 64905 64284 61452 61123 61660 61658 61289 60141 57997 56961 65554 62385 2191 58312 65338 63559 1178 TPGW-12D 64750 64677 64716 64326 64428 64116 65266 64582 64361 64483 64489 64185 63582 65573 64515 320 62948 65028 64032 399

FPL Turkey Point Annual Post-Uprate Monitoring Report for Units 3 & 4 Uprate Project - August 2014 Section 2 2-19 Table 2.1-1. Statistical Summary of Automated Groundwater Specific Conductance (S/cm) 2013 2014 Post-Uprate Pre-Uprate Well Jun Jul Aug Sep Oct Nov Dec Jan Feb Mar Apr May Min Max Avg Std Dev Min Max Avg Std Dev TPGW-13S 83681 83930 83896 84093 84097 83271 82961 82321 82076 81825 81708 81631 81384 85428 82968 984 81674 86909 84173 1191 TPGW-13M 79112 79426 79264 78816 78739 78752 78771 78448 78320 78060 77693 77695 77420 82175 78581 560 79026 83273 80759 1027 TPGW-13D 80765 81290 81157 79888 NA 80537 80897 80004 79742 79399 79112 79117 77542 82488 80172 850 80256 84564 82447 893 TPGW-14S 57606 58032 57687 57512 57303 57053 57301 57454 57573 57629 57607 56707 56564 58231 57448 377 56922 59860 58318 796 TPGW-14M 62941 63035 62718 62090 61900 61857 62340 62075 62089 62185 62249 61608 60917 64095 62260 505 61767 67002 63581 1014 TPGW-14D 73590 73673 73701 73963 73922 73389 73238 73989 74058 73624 73221 73767 72904 74537 73654 310 72365 75797 73919 730 Key:

µs/cm = Micro Siemens per centimeter.

Avg = Average.

Max = Maximum.

Min = Minimum.

NA = Not available.

Std Dev = Standard Deviation.

FPL Turkey Point Annual Post-Uprate Monitoring Report for Units 3 & 4 Uprate Project - August 2014 Section 2 2-20 Table 2.1-2. Statistical Summary of Automated Groundwater Temperature (°C) 2013 2014 Post-Uprate Pre-Uprate Well Jun Jul Aug Sep Oct Nov Dec Jan Feb Mar Apr May Min Max Avg Std Dev Min Max Avg Std Dev TPGW-1S 25.7 25.6 25.5 25.5 25.5 25.6 25.7 25.7 25.7 25.8 25.8 25.8 25.5 25.9 25.7 0.1 25.4 25.8 25.6 0.1 TPGW-1M 25.9 25.9 25.9 25.8 25.8 25.8 25.8 25.8 25.8 25.8 25.9 25.9 25.8 25.9 25.9 0.0 25.9 26.0 26.0 0.0 TPGW-1D 25.9 25.9 25.9 25.9 25.9 25.9 25.9 25.9 25.9 25.9 25.9 25.9 25.9 25.9 25.9 0.0 26.1 26.2 26.1 0.0 TPGW-2S 26.0 25.8 25.7 25.8 25.8 25.9 26.0 26.0 26.1 26.1 26.1 26.4 25.7 26.6 26.0 0.2 25.6 27.5 26.6 0.4 TPGW-2M 26.9 26.8 26.7 26.7 26.6 26.6 26.6 26.6 26.6 26.6 26.6 26.6 26.6 27.0 26.7 0.1 26.7 27.4 27.1 0.1 TPGW-2D 27.1 27.1 27.1 27.1 27.1 27.0 27.0 27.0 27.0 27.0 27.0 27.0 27.0 27.1 27.0 0.0 27.4 27.6 27.4 0.1 TPGW-3S 25.7 25.7 25.7 25.8 25.9 25.9 26.0 26.1 26.1 26.0 25.9 25.8 25.6 26.1 25.9 0.1 25.6 26.2 25.9 0.2 TPGW-3M 25.9 25.9 25.9 25.9 25.9 25.9 25.9 25.9 25.8 25.8 25.8 25.8 25.8 25.9 25.9 0.0 25.9 26.0 25.9 0.0 TPGW-3D 25.7 25.7 25.7 25.7 25.7 25.7 25.7 25.7 25.7 25.7 25.7 25.7 25.7 25.7 25.7 0.0 25.7 25.8 25.8 0.0 TPGW-4S 24.9 24.8 24.7 NA 25.0 25.1 25.2 25.3 25.2 25.1 25.0 25.0 24.7 25.3 25.1 0.2 24.2 25.3 24.8 0.3 TPGW-4M 24.8 24.8 24.8 NA 24.7 24.7 24.7 24.7 24.7 24.7 24.7 24.7 24.7 24.8 24.7 0.1 24.4 24.6 24.5 0.1 TPGW-4D 24.5 24.5 24.5 24.5 24.5 24.5 24.5 24.5 24.5 24.5 24.5 24.5 24.5 24.5 24.5 0.0 24.3 24.5 24.4 0.0 TPGW-5S 23.6 23.5 23.5 23.5 23.5 23.6 23.7 23.7 23.8 23.7 23.6 23.6 23.4 23.8 23.6 0.1 23.3 23.8 23.5 0.2 TPGW-5M 23.7 23.6 23.6 23.6 23.6 23.6 23.6 23.6 23.6 23.6 23.7 23.7 23.6 23.7 23.6 0.0 23.5 23.6 23.5 0.0 TPGW-5D 23.7 23.7 23.7 23.7 23.7 23.7 23.7 23.7 23.7 23.7 23.7 23.7 23.7 23.7 23.7 0.0 23.6 23.7 23.7 0.0 TPGW-6S 23.1 23.1 23.2 23.3 23.4 23.5 23.5 23.5 23.5 23.5 23.5 23.5 23.1 23.5 23.4 0.1 23.0 23.7 23.4 0.2 TPGW-6M 23.6 23.6 23.5 23.5 23.5 23.5 23.5 23.5 23.5 23.5 23.5 23.5 23.5 23.6 23.5 0.0 23.5 23.7 23.6 0.0 TPGW-6D 23.5 23.5 23.5 23.5 23.5 23.5 23.5 23.5 23.5 23.5 23.5 23.5 23.5 23.6 23.5 0.0 23.5 23.6 23.5 0.0 TPGW-7S 23.7 23.7 23.7 23.7 23.8 NA NA 23.8 23.9 23.9 23.8 23.8 23.7 26.3 23.8 0.1 23.6 24.0 23.8 0.1 TPGW-7M 23.8 23.8 23.8 23.8 23.8 23.8 23.7 23.7 23.7 23.8 23.8 23.8 23.7 23.9 23.8 0.0 23.7 23.9 23.8 0.1 TPGW-7D 23.8 23.8 23.8 23.8 23.8 23.8 23.8 23.8 23.8 23.8 23.8 23.8 23.8 23.8 23.8 0.0 23.9 23.9 23.9 0.0 TPGW-8S 23.6 23.5 23.6 23.7 23.8 23.9 23.9 23.9 23.8 23.6 23.5 23.5 23.5 24.0 23.7 0.2 23.3 24.1 23.7 0.3 TPGW-8M 23.7 NA 23.6 23.6 23.6 23.6 23.6 23.6 23.6 23.6 23.6 23.7 23.6 23.7 23.6 0.0 23.6 23.8 23.7 0.1 TPGW-8D 23.7 23.7 23.7 23.7 23.7 23.7 23.7 23.7 23.7 23.7 23.7 23.7 23.6 23.9 23.7 0.0 23.5 23.8 23.7 0.0 TPGW-9S 24.4 24.4 24.5 24.7 24.9 25.0 25.0 24.9 24.8 24.5 24.3 24.3 24.2 25.1 24.6 0.3 24.2 25.3 24.7 0.4 TPGW-9M 23.9 23.8 23.8 23.8 23.8 23.8 23.8 23.9 23.9 23.9 23.9 23.8 23.8 23.9 23.8 0.0 23.6 24.2 23.9 0.2 TPGW-9D 24.0 24.0 24.0 24.0 24.0 24.0 24.0 24.0 24.0 24.0 24.0 24.0 23.9 24.0 24.0 0.0 24.0 24.1 24.0 0.0 TPGW-10S 25.8 25.9 25.9 26.0 26.2 26.3 26.4 26.4 26.4 26.3 26.2 26.1 25.8 26.5 26.2 0.2 25.5 26.6 26.1 0.3 TPGW-10M 25.9 25.9 25.9 25.9 25.9 25.9 25.9 25.9 25.9 25.9 25.9 25.9 25.9 26.0 25.9 0.0 25.8 25.9 25.8 0.0 TPGW-10D 25.6 25.6 25.6 25.6 25.6 25.6 25.6 25.6 25.6 25.6 25.6 25.6 25.6 25.7 25.6 0.0 25.7 25.7 25.7 0.0 TPGW-11S 25.2 25.2 25.2 25.3 25.4 25.5 25.6 25.6 25.5 25.4 25.4 25.4 25.1 25.7 25.4 0.1 25.0 25.5 25.3 0.2 TPGW-11M 25.3 25.3 25.3 25.3 25.3 25.3 25.3 25.3 25.3 25.3 25.3 25.3 25.3 25.3 25.3 0.0 25.3 25.4 25.3 0.0 TPGW-11D 25.3 25.3 25.3 25.3 25.3 25.3 25.3 25.3 25.3 25.3 25.3 25.3 25.2 25.3 25.3 0.0 25.3 25.3 25.3 0.0 TPGW-12S 25.9 25.8 25.8 25.9 25.9 25.9 26.0 26.1 26.1 26.1 26.0 25.9 25.8 26.1 26.0 0.1 25.8 26.3 26.0 0.1 TPGW-12M 26.0 26.0 26.0 26.0 26.0 26.0 26.0 26.0 26.0 26.0 26.0 25.9 25.9 26.0 26.0 0.0 26.0 26.2 26.1 0.0 TPGW-12D 26.0 26.0 26.0 26.0 26.0 26.0 26.0 26.0 26.0 26.0 26.0 26.0 26.0 26.0 26.0 0.0 26.0 26.2 26.1 0.0

FPL Turkey Point Annual Post-Uprate Monitoring Report for Units 3 & 4 Uprate Project - August 2014 Section 2 2-21 Table 2.1-2. Statistical Summary of Automated Groundwater Temperature (°C) 2013 2014 Post-Uprate Pre-Uprate Well Jun Jul Aug Sep Oct Nov Dec Jan Feb Mar Apr May Min Max Avg Std Dev Min Max Avg Std Dev TPGW-13S 29.5 29.4 29.3 29.3 29.3 29.3 29.4 29.4 29.5 29.5 29.5 29.6 29.3 29.6 29.4 0.1 29.3 30.5 30.0 0.4 TPGW-13M 29.4 29.3 29.3 29.3 29.3 29.2 29.2 29.2 29.2 29.2 29.2 29.2 29.2 29.4 29.3 0.1 29.4 29.6 29.5 0.0 TPGW-13D 29.1 29.1 29.1 28.7 NA 29.1 29.1 29.1 29.0 29.0 29.0 29.0

-16.0 29.1 29.1 0.5 29.4 29.5 29.4 0.0 TPGW-14S 25.8 25.9 26.0 26.0 26.2 26.3 26.4 26.4 26.4 26.3 26.2 26.0 25.7 26.5 26.1 0.2 25.5 26.4 26.0 0.3 TPGW-14M 26.2 26.2 26.2 26.2 26.2 26.2 26.2 26.2 26.2 26.2 26.2 26.2 26.2 26.3 26.2 0.0 26.1 26.2 26.2 0.0 TPGW-14D 26.3 26.3 26.4 26.4 26.3 26.3 26.3 26.4 26.4 26.4 26.4 26.4 26.3 26.4 26.4 0.0 26.3 26.4 26.4 0.0 Key:

°C = Degrees Celsius.

Avg = Average.

Max = Maximum.

Min = Minimum.

NA = Not available.

Std Dev = Standard Deviation.

FPL Turkey Point Annual Post-Uprate Monitoring Report for Units 3 & 4 Uprate Project - August 2014 Section 2 2-22 Table 2.1-3. Statistical Summary of Automated Groundwater Salinity (PSS-78)

Post-Uprate Pre-Uprate Well Min Max Avg Std Dev Min Max Avg Std Dev TPGW-1S 25.5 41.4 33.4 4.2 31.7 44.1 38.3 2.5 TPGW-1M 49.4 50.5 50.0 0.3 46.1 53.1 49.5 0.9 TPGW-1D 48.6 50.2 49.4 0.4 48.4 50.8 49.7 0.4 TPGW-2S 45.2 50.4 46.9 0.8 47.5 54.6 51.4 1.4 TPGW-2M 51.7 53.9 52.7 0.4 51.3 54.8 53.1 0.6 TPGW-2D 52.4 54.6 53.2 0.5 50.5 54.6 53.3 0.4 TPGW-3S 36.8 45.3 43.1 1.6 41.8 45.2 43.6 0.4 TPGW-3M 46.0 47.8 47.1 0.4 46.2 49.0 47.8 0.4 TPGW-3D 47.1 48.8 48.0 0.3 46.1 48.8 47.8 0.6 TPGW-4S 0.6 2.8 1.1 0.4 0.6 2.1 1.2 0.2 TPGW-4M 24.6 25.8 25.1 0.4 23.1 25.0 24.2 0.3 TPGW-4D 27.3 28.5 28.0 0.3 26.9 28.8 28.0 0.4 TPGW-5S 0.3 0.6 0.4 0.1 0.0 1.0 0.7 0.1 TPGW-5M 20.3 20.9 20.7 0.2 18.6 20.5 19.5 0.5 TPGW-5D 21.6 22.1 21.9 0.1 19.7 21.7 21.1 0.4 TPGW-6S 0.5 0.6 0.6 0.0 0.5 0.6 0.6 0.0 TPGW-6M 13.7 14.0 13.8 0.1 13.2 14.2 13.8 0.2 TPGW-6D 14.0 14.5 14.4 0.1 13.8 15.2 14.5 0.2 TPGW-7S 0.2 0.3 0.3 0.0 0.2 0.4 0.3 0.0 TPGW-7M 0.3 0.3 0.3 0.0 0.3 0.4 0.3 0.0 TPGW-7D 0.3 2.3 1.0 0.7 0.2 0.3 0.3 0.0 TPGW-8S 0.8 1.2 1.0 0.1 1.1 2.0 1.5 0.2 TPGW-8M 0.3 0.3 0.3 0.0 0.3 0.3 0.3 0.0 TPGW-8D 0.1 0.3 0.3 0.0 0.1 0.4 0.3 0.0 TPGW-9S 0.3 0.3 0.3 0.0 0.0 0.3 0.3 0.0 TPGW-9M 0.3 0.3 0.3 0.0 0.3 0.4 0.3 0.0 TPGW-9D 0.3 0.3 0.3 0.0 0.3 0.3 0.3 0.0 TPGW-10S 34.8 36.7 35.5 0.3 33.3 35.7 34.4 0.7 TPGW-10M 36.7 37.9 37.3 0.3 36.0 37.7 36.8 0.4 TPGW-10D 43.6 46.3 45.4 0.5 36.2 38.1 37.1 0.4 TPGW-11S 36.6 38.3 37.3 0.4 35.7 37.8 36.7 0.6 TPGW-11M 38.1 40.2 38.9 0.5 37.0 39.1 38.0 0.5 TPGW-11D 41.6 43.6 42.4 0.5 37.2 40.3 39.3 0.4 TPGW-12S 25.2 31.4 29.1 0.6 25.0 30.0 26.9 0.7 TPGW-12M 38.6 45.2 42.8 1.7 39.6 45.1 43.7 0.9 TPGW-12D 43.7 45.3 44.4 0.3 43.2 44.8 44.0 0.3

FPL Turkey Point Annual Post-Uprate Monitoring Report for Units 3 & 4 Uprate Project - August 2014 Section 2 2-23 Table 2.1-3. Statistical Summary of Automated Groundwater Salinity (PSS-78)

Post-Uprate Pre-Uprate Well Min Max Avg Std Dev Min Max Avg Std Dev TPGW-13S 58.2 61.6 59.5 0.8 58.5 62.9 60.6 1.0 TPGW-13M 54.9 58.9 55.9 0.5 56.3 59.8 57.7 0.9 TPGW-13D 55.0 59.1 57.2 0.7 57.3 60.9 59.1 0.7 TPGW-14S 38.3 39.5 38.9 0.3 38.5 40.8 39.6 0.6 TPGW-14M 41.6 44.1 42.7 0.4 42.3 46.2 43.7 0.8 TPGW-14D 51.1 52.4 51.7 0.3 50.7 53.5 51.9 0.6 Key:

Avg = Average.

Max = Maximum.

Min = Minimum.

Std Dev = Standard Deviation.

FPL Turkey Point Annual Post-Uprate Monitoring Report for Units 3 & 4 Uprate Project - August 2014 Section 2 2-24 Table 2.2-1. Probe Types/Automated Measurements at Surface Water Stations for Post-Uprate Monitoring Period Surface Water Site Probe Parameters Measured TPSWC-1T AT200 Water Quality, Stage TPSWC-1B AT100 Water Quality TPSWC-2T AT200 Water Quality, Stage TPSWC-2B AT100 Water Quality TPSWC-3T AT200 Water Quality, Stage TPSWC-3B AT100 Water Quality TPSWC-4T AT200 Water Quality, Stage TPSWC-4B AT100 Water Quality TPSWC-5T AT200 Water Quality, Stage TPSWC-5B AT100 Water Quality TPSWID-1T AT200 Water Quality, Stage TPSWID-1B AT100 Water Quality TPSWID-2T AT200 Water Quality, Stage TPSWID-3T AT100 Water Quality TPSWID-3B AT200 Water Quality, Stage TPSWCCS-1T AT200 Water Quality, Stage TPSWCCS-2T AT200 Water Quality, Stage TPSWCCS-3T AT200 Water Quality, Stage TPSWCCS-4T AT200 Water Quality, Stage TPSWCCS-5T AT200 Water Quality, Stage TPSWCCS-6T AT200 Water Quality, Stage TPBBSW-3B AT200 Water Quality, Stage TPBBSW-4B AT100 Water Quality TPBBSW-5B AT100 Water Quality TPBBSW-10B AT200 Water Quality, Stage TPBBSW-14B AT200 Water Quality, Stage Note:

Pre-Uprate station probes TPBBSW-1B, TPBBSW-2B, TPSWCCS-4B, TPSWCCS-5B, and TPSWCCS-6B are not shown since they were eliminated for the Post-Uprate monitoring.

Key:

AT - Aqua TROLL.

B - Bottom.

LT - Level TROLL.

T - Top.

FPL Turkey Point Annual Post-Uprate Monitoring Report for Units 3 & 4 Uprate Project - August 2014 Section 2 2-25 Table 2.2-2. Statistical Summary of Automated Surface Water Specific Conductance (µS/cm)

Well 2013 2014 Post-Uprate Pre-Uprate Jun Jul Aug Sep Oct Nov Dec Jan Feb Mar Apr May Min Max Avg Std Dev Min Max Avg Std Dev TPBBSW-3B 53150 51154 51982 48521 43861 43577 45257 44408 50470 53640 57614 58836 35166 60557 50244 5527 28789 63371 49218 7445 TPBBSW-4B 52832 NA 50868 51220 50044 47911 47979 48985 50050 51881 56384 58224 39614 59330 51479 3452 36028 61649 51129 6361 TPBBSW-5B 48304 47148 45880 48113 48211 46820 45653 47433 48232 49206 53290 57686 40553 60277 48962 3671 32263 64177 49179 7431 TPBBSW-10B 51363 48222 48609 41957 36042 38377 37433 40049 44732 49396 56455 61453 22315 63186 46174 8566 18922 64623 47772 10258 TPBBSW-14B 48640 48092 45786 46241 47742 42631 45778 44621 48657 52212 55969 58905 37975 60196 48753 4741 35635 49933 42282 3686 TPSWC-1T 388 445 650 527 483 673 703 676 691 850 1118 1619 333 1939 733 334 315 3574 813 445 TPSWC-1B 764 711 809 787 733 895 647 916 954 971 1121 1407 562 1649 891 219 387 3158 993 562 TPSWC-2T 592 586 511 571 579 862 689 683 783 978 1740 6555 393 9530 1258 1769 256 6194 1281 1317 TPSWC-2B 952 840 715 933 1002 1237 1150 790 807 1044 1986 8828 444 11585 1690 2266 267 9507 1522 1756 TPSWC-3T 594 630 498 588 749 1378 713 809 1061 1605 3247 6963 377 9498 1560 1865 265 5864 1440 1260 TPSWC-3B 3361 2299 2028 2124 3047 3728 3885 3031 3115 3082 5149 17445 1335 18295 4419 4142 265 22776 3553 5498 TPSWC-4T 39424 32492 31131 35865 44809 34667 26788 26092 18401 17734 26948 58883 15508 62425 32271 12907 378 62601 30178 19440 TPSWC-4B 43774 34951 35021 39177 31219 42239 30746 29103 16739 17706 28219 59245 6351 66755 34250 13150 388 63843 35842 19796 TPSWC-5T 51015 48124 48105 50335 48906 46429 47597 48816 49975 52166 55285 58462 40486 59524 50457 3694 27741 61200 50395 6594 TPSWC-5B 54610 53293 55156 50645 48431 46400 45080 48703 49367 51551 54597 56934 42690 59354 51296 3769 43281 71282 57572 4438 TPSWCCS-1B 78187 83032 83049 85815 89202 93389 93156 97288 102182 108457 117225 118451 72545 121860 95531 13089 54595 88321 75307 7906 TPSWCCS-2B 77366 81440 82142 85770 88842 92632 91941 96670 101899 109417 117333 119002 71802 122533 95135 13580 64216 87632 81273 3619 TPSWCCS-3B 76447 80998 80340 82861 84994 90438 90513 89712 91944 100496 109999 117386 71469 123743 91099 12063 53565 88238 75627 6884 TPSWCCS-4T 76883 80806 79428 83627 89089 93915 91611 95228 100060 95094 116521 118056 66629 120953 93109 13601 55754 90575 79288 6544 TPSWCCS-5T 74402 79098 77156 82986 86102 90271 87738 87113 88185 96678 99844 111813 72146 118728 88352 10806 54602 89303 78069 7024 TPSWCCS-7B 78082 82279 83288 85972 89183 93681 93820 96763 101357 106114 109250 111010 43516 120329 92221 10647 53511 85289 70798 5508 TPSWID-1T 3580 4030 3427 3384 3256 3840 3453 3809 4152 7587 7206 8389 2101 45621 12200 10291 2101 45621 12200 10291 TPSWID-1B 12153 9139 3805 5289 5828 4019 3821 5493 7917 16152 14297 19343 1847 21884 9014 5271 2109 48037 16595 12223 TPSWID-2T 3382 3811 2473 3113 2901 3267 2958 3665 3590 3435 3867 4787 2069 6307 3444 641 1441 55392 9361 11190 TPSWID-2B 13807 10562 7621 6227 4799 3460 3684 4009 5605 5875 5992 8166 2824 20016 6788 3270 2146 68416 28356 23449 TPSWID-3T 3413 3254 2454 2476 4120 6690 2964 3198 3199 3250 3575 6112 2309 11831 3731 1603 1177 62140 7868 12473 TPSWID-3B 3408 3263 2497 2621 5103 8375 3353 3243 3230 3285 4073 18249 2253 35500 5062 4926 1211 66206 12920 19165 Key:

µS/cm = Micro Siemens per centimeter.

Avg = Average.

Max = Maximum.

Min = Minimum.

NA = Not available.

Std Dev = Standard Deviation.

FPL Turkey Point Annual Post-Uprate Monitoring Report for Units 3 & 4 Uprate Project - August 2014 Section 2 2-26 Table 2.2-3. Statistical Summary of Automated Surface Water Temperature (°C)

Well 2013 2014 Post-Uprate Pre-Uprate Jun Jul Aug Sep Oct Nov Dec Jan Feb Mar Apr May Min Max Avg Std Dev Min Max Avg Std Dev TPBBSW-3B 29.6 29.1 30.0 29.5 27.6 24.8 24.0 20.5 24.7 24.2 26.2 27.5 15.4 33.3 26.5 3.3 9.5 34.8 25.1 4.4 TPBBSW-4B 28.5 NA 30.0 29.5 27.9 24.8 24.0 20.9 24.8 24.6 26.3 27.5 17.5 31.4 26.0 2.9 15.9 33.7 26.2 3.7 TPBBSW-5B 30.0 29.6 30.4 29.9 28.1 25.1 24.3 21.3 25.0 24.8 26.6 27.8 17.1 32.8 26.8 3.1 15.8 34.5 26.4 3.7 TPBBSW-10B 29.8 29.6 30.2 29.9 27.9 24.6 24.0 20.4 24.9 24.3 26.3 27.5 15.5 33.7 26.6 3.3 14.9 35.2 26.2 3.8 TPBBSW-14B 29.7 29.4 30.1 29.6 27.9 24.8 24.0 20.9 24.9 24.6 26.4 27.5 17.6 32.3 26.7 3.0 16.6 33.9 26.4 3.7 TPSWC-1T 29.5 29.3 29.9 28.9 27.6 25.1 24.1 21.4 24.8 25.4 27.4 28.8 18.0 31.6 26.9 2.8 14.5 33.7 25.7 4.0 TPSWC-1B 27.0 27.7 28.9 27.9 27.0 24.9 23.6 21.0 22.7 24.6 26.0 27.6 19.1 29.6 25.7 2.4 14.7 30.6 24.6 3.9 TPSWC-2T 29.7 29.8 30.0 29.1 27.8 25.0 24.2 21.4 25.0 25.2 27.3 28.9 17.8 32.0 27.0 2.9 14.1 34.8 25.4 4.0 TPSWC-2B 28.4 28.6 29.2 28.4 27.3 24.8 23.5 20.7 23.6 24.7 26.8 29.9 18.5 31.8 26.4 2.9 14.0 31.8 24.7 4.1 TPSWC-3T 30.3 30.1 30.5 29.7 28.2 25.1 24.1 21.4 24.8 25.4 27.4 28.5 18.3 33.1 27.2 3.1 15.1 33.6 25.9 4.0 TPSWC-3B 29.7 29.7 29.9 29.1 27.5 24.8 23.5 20.5 23.3 25.0 27.5 29.8 18.2 31.9 26.7 3.3 15.0 32.2 25.5 4.3 TPSWC-4T 27.9 28.6 28.7 29.8 30.0 24.9 26.0 22.8 25.4 25.6 27.9 29.3 19.2 32.9 27.3 2.5 18.2 34.4 26.8 3.0 TPSWC-4B 27.8 28.6 28.7 30.1 29.2 26.2 25.9 22.8 25.5 25.8 27.9 29.3 19.3 32.0 27.3 2.4 17.4 34.5 27.0 3.0 TPSWC-5T 30.0 29.8 30.5 30.0 28.6 25.3 24.6 21.6 25.1 25.4 26.8 28.3 18.8 33.4 27.2 2.9 13.8 34.5 26.3 4.2 TPSWC-5B 27.8 30.0 30.6 30.2 28.8 25.8 24.7 21.6 24.1 25.1 26.1 27.9 19.2 33.1 26.9 2.9 16.4 34.9 27.5 3.8 TPSWCCS-1B 41.7 41.1 42.0 41.6 40.7 37.5 36.5 34.3 39.5 37.7 37.7 41.7 27.8 44.7 39.2 3.0 18.0 43.8 34.4 4.2 TPSWCCS-2B 35.3 35.4 36.5 36.5 34.4 31.2 31.4 29.3 33.5 31.2 32.2 35.3 21.4 42.3 33.5 3.4 14.5 38.2 29.8 4.1 TPSWCCS-3B 34.6 34.6 35.5 35.1 33.0 29.8 29.9 27.8 32.1 30.9 32.8 33.8 20.0 39.4 32.5 3.1 14.8 39.8 29.3 4.2 TPSWCCS-4T 33.1 33.0 33.9 33.7 31.6 28.4 28.5 26.2 30.4 29.2 30.8 32.4 18.1 38.1 30.9 3.2 12.4 37.8 27.9 4.2 TPSWCCS-5T 33.0 32.9 33.9 33.6 31.5 28.3 28.4 26.0 30.2 29.1 30.8 32.3 18.2 37.2 30.8 3.1 12.8 37.0 27.3 4.0 TPSWCCS-7B 37.8 37.5 38.5 38.4 36.7 33.3 33.2 31.4 35.7 31.2 30.1 36.0 16.3 43.1 35.0 4.0 15.7 42.6 31.7 4.2 TPSWID-1T 30.4 30.2 31.1 29.8 28.3 25.5 24.8 22.8 25.8 26.0 27.7 28.6 16.8 36.3 26.7 3.6 16.8 36.3 26.7 3.6 TPSWID-1B 30.3 29.9 30.8 30.1 28.8 25.2 24.4 23.0 25.9 27.7 28.2 29.4 20.2 31.7 27.8 2.6 16.8 33.9 26.9 3.2 TPSWID-2T 29.6 29.6 30.2 29.6 28.5 25.8 25.2 23.4 25.8 25.7 27.2 28.5 21.1 32.2 27.4 2.3 18.8 33.6 26.7 3.1 TPSWID-2B 27.6 27.4 27.4 27.6 27.8 25.6 25.1 23.1 25.6 26.2 27.1 28.0 21.2 28.9 26.6 1.5 18.8 32.5 27.5 2.6 TPSWID-3T 29.4 29.3 30.1 29.5 28.6 25.8 24.8 23.1 25.6 25.6 27.0 28.3 20.6 31.8 27.3 2.3 18.3 34.4 26.7 3.3 TPSWID-3B 28.6 28.5 29.1 28.6 28.4 25.8 24.5 22.7 25.2 25.2 26.4 28.2 20.6 30.0 26.8 2.2 18.1 33.8 26.3 3.0 Key:

°C = Degrees Celsius.

Avg = Average.

Max = Maximum.

Min = Minimum.

Std Dev = Standard Deviation.

FPL Turkey Point Annual Post-Uprate Monitoring Report for Units 3 & 4 Uprate Project - August 2014 Section 2 2-27 Table 2.2-4. Statistical Summary of Automated Surface Water Salinity (PSS-78)

Well Post-Uprate Pre-Uprate Min Max Avg Std Dev Min Max Avg Std Dev TPBBSW-3B 22.5 41.4 33.5 4.2 18.0 43.7 32.7 5.6 TPBBSW-4B 25.6 40.4 34.4 2.6 23.1 42.3 34.2 4.8 TPBBSW-5B 26.4 41.2 32.5 2.8 20.4 44.3 32.7 5.6 TPBBSW-10B 13.6 43.5 30.5 6.3 11.4 44.5 31.8 7.6 TPBBSW-14B 24.4 41.1 32.4 3.6 22.8 31.9 27.6 2.7 TPSWC-1T 0.2 1.0 0.4 0.2 0.2 1.9 0.4 0.2 TPSWC-1B 0.3 0.8 0.4 0.1 0.2 1.7 0.5 0.3 TPSWC-2T 0.2 5.4 0.7 1.0 0.1 3.4 0.7 0.7 TPSWC-2B 0.2 6.7 0.9 1.3 0.1 5.4 0.8 1.0 TPSWC-3T 0.2 5.4 0.8 1.1 0.1 3.2 0.7 0.7 TPSWC-3B 0.7 11.0 2.4 2.5 0.1 14.0 2.0 3.3 TPSWC-4T 9.2 42.9 20.7 9.2 0.2 43.1 19.6 13.2 TPSWC-4B 3.5 46.2 22.1 9.3 0.2 43.7 23.6 13.5 TPSWC-5T 26.2 40.6 33.7 2.8 17.5 42.0 33.6 4.9 TPSWC-5B 27.8 40.4 34.3 2.9 28.2 49.1 39.1 3.5 TPSWCCS-1B 51.1 94.9 70.9 11.7 36.9 64.3 53.4 6.4 TPSWCCS-2B 50.4 95.5 70.4 12.0 44.2 63.7 58.1 3.1 TPSWCCS-3B 50.2 96.6 66.8 10.6 36.7 64.2 53.5 5.7 TPSWCCS-4T 46.3 93.8 68.5 12.0 37.7 65.8 56.4 5.4 TPSWCCS-5T 50.7 91.8 64.3 9.4 39.2 64.7 55.4 5.7 TPSWCCS-7B 28.6 93.2 67.8 9.3 36.0 61.5 49.6 4.4 TPSWID-1T 1.1 30.1 7.3 6.6 1.1 30.1 7.3 6.6 TPSWID-1B 0.9 13.4 5.2 3.3 1.1 31.9 10.2 8.0 TPSWID-2T 1.1 3.5 1.8 0.4 0.7 37.4 5.6 7.3 TPSWID-2B 1.5 12.1 3.8 2.0 1.1 47.6 18.6 16.4 TPSWID-3T 1.2 6.9 2.0 0.9 0.6 42.7 4.8 8.4 TPSWID-3B 1.2 22.7 2.8 3.1 0.6 45.9 8.2 13.3 Key:

Avg = Average.

Max = Maximum.

Min = Minimum.

PSS-78 = Practical Salinity Scale of 1978.

Std Dev = Standard Deviation.

FPL Turkey Point Annual Post-Uprate Monitoring Report for Units 3 & 4 Uprate Project - August 2014 Section 2 2-28 Table 2.4-1. Parameters Collected at Hourly Intervals Reported by the Meteorological Station at TPM-1 Parameter Units Accuracy Resolution Rainfall - Amount inches Better than 5%,

weather dependent 0.001 Relative Humidity

+/- 3 0.1 Temperature

°Celsius

+/- 0.3

+/- 0.1 Barometric Pressure mmHg 0.5 0.5 Wind Speed-Average mph 1 ft/sec 0.3 ft/sec Wind Speed-Gusts and Lull mph 1 ft/sec 0.3 ft/sec Wind Direction degrees

+/- 3 1

Light Level

µmol m-2 s-1 5-10 µA/100 µmol m-2 s-1 NA Hail Hits 1

1 Key:

ft/sec = Feet per second.

mmHg = Millimeters of mercury.

mph = Miles per hour.

NA = Not applicable.

mol m-2 s = Micromoles per meter square per second.

FPL Turkey Point Annual Post-Uprate Monitoring Report for Units 3 & 4 Uprate Project - August 2014 Section 2 2-29 Table 2.4-2. Rainfall Recorded at the Meteorological Station TPM-1 (June 2013 -

May 2014)

Month Day Year Rain (in) 6 2

2013 0.06 6

3 2013 0.03 6

4 2013 0.01 6

6 2013 0.16 6

7 2013 0.08 6

8 2013 0.02 6

9 2013 0.14 6

10 2013 0.06 6

27 2013 0.03 6

30 2013 0.01 7

1 2013 0.04 7

2 2013 0.08 7

3 2013 0.05 7

4 2013 0.08 7

5 2013 0.19 7

10 2013 0.13 7

11 2013 0.05 7

12 2013 0.03 7

13 2013 0.09 7

14 2013 0.01 7

15 2013 0.02 7

16 2013 0.01 7

17 2013 0.79 7

18 2013 0.25 7

24 2013 0.02 7

27 2013 0.01 7

29 2013 0.56 7

31 2013 0.01 8

2 2013 0.15 8

3 2013 0.27 8

5 2013 0.03 8

6 2013 0.06 8

9 2013 0.02 8

14 2013 0.18 8

15 2013 0.12 8

17 2013 0.02 8

18 2013 0.01 Month Day Year Rain (in) 8 19 2013 0.03 8

20 2013 0.16 8

22 2013 0.03 8

27 2013 0.02 8

28 2013 0.17 8

31 2013 0.02 9

2 2013 0.04 9

4 2013 0.01 9

5 2013 0.14 9

7 2013 0.50 9

10 2013 0.02 9

11 2013 0.01 9

12 2013 0.04 9

14 2013 0.01 9

15 2013 0.26 9

16 2013 0.17 9

17 2013 0.12 9

19 2013 0.20 9

20 2013 0.27 9

23 2013 0.30 9

25 2013 0.01 9

28 2013 0.17 10 1

2013 0.02 10 8

2013 0.18 10 10 2013 0.01 10 16 2013 0.01 10 19 2013 0.33 10 21 2013 0.01 10 22 2013 0.01 10 23 2013 0.36 10 24 2013 0.40 10 29 2013 0.01 10 31 2013 0.01 11 4

2013 0.12 11 9

2013 0.13 11 10 2013 0.01 11 13 2013 0.16

FPL Turkey Point Annual Post-Uprate Monitoring Report for Units 3 & 4 Uprate Project - August 2014 Section 2 2-30 Table 2.4-2. Rainfall Recorded at the Meteorological Station TPM-1 (June 2013 -

May 2014)

Month Day Year Rain (in) 11 19 2013 0.09 11 21 2013 0.01 11 22 2013 0.19 11 24 2013 0.37 11 26 2013 0.06 11 27 2013 0.52 11 30 2013 0.47 12 1

2013 0.001 12 3

2013 0.001 12 4

2013 0.003 12 5

2013 0.001 12 8

2013 0.004 12 13 2013 0.001 12 15 2013 0.005 12 16 2013 0.025 12 17 2013 0.001 12 20 2013 0.001 12 25 2013 0.008 12 26 2013 0.287 12 29 2013 0.003 1

1 2014 0.001 1

4 2014 0.014 1

5 2014 0.007 1

6 2014 0.148 1

7 2014 0.007 1

8 2014 0.082 1

9 2014 0.032 1

12 2014 0.007 1

15 2014 0.006 1

21 2014 0.043 1

29 2014 0.008 1

30 2014 0.278 2

7 2014 0.002 2

8 2014 0.002 2

12 2014 0.287 2

13 2014 0.021 2

15 2014 0.001 Month Day Year Rain (in) 2 27 2014 0.139 2

28 2014 0.053 3

5 2014 0.044 3

6 2014 0.250 3

9 2014 0.001 3

14 2014 0.002 3

15 2014 0.001 3

17 2014 0.003 3

18 2014 0.051 3

20 2014 0.001 3

22 2014 0.045 3

23 2014 0.003 3

24 2014 0.001 3

25 2014 0.380 3

28 2014 0.001 3

29 2014 0.193 3

30 2014 0.016 3

31 2014 0.001 4

4 2014 0.002 4

7 2014 0.002 4

8 2014 0.044 4

10 2014 0.001 4

11 2014 0.001 4

13 2014 0.002 4

17 2014 0.079 4

18 2014 0.007 4

20 2014 0.002 4

21 2014 0.001 4

22 2014 0.006 4

23 2014 0.005 4

24 2014 0.001 4

25 2014 0.004 4

26 2014 0.005 4

27 2014 0.008 4

28 2014 0.005 4

29 2014 0.005 4

30 2014 0.002

FPL Turkey Point Annual Post-Uprate Monitoring Report for Units 3 & 4 Uprate Project - August 2014 Section 2 2-31 Table 2.4-2. Rainfall Recorded at the Meteorological Station TPM-1 (June 2013 -

May 2014)

Month Day Year Rain (in) 5 2

2014 0.001 5

3 2014 0.097 5

4 2014 0.005 5

5 2014 0.009 5

6 2014 0.003 5

7 2014 0.004 5

8 2014 0.002 5

11 2014 0.002 5

12 2014 0.006 5

13 2014 0.022 5

14 2014 0.128 5

15 2014 0.016 5

16 2014 0.002 5

17 2014 0.001 5

18 2014 0.001 5

21 2014 0.003 5

22 2014 0.002 5

27 2014 0.005 5

29 2014 0.004 Key:

in = inches.

TPM = Turkey Point Meteorological.

FPL Turkey Point Annual Post-Uprate Monitoring Report for Units 3 & 4 Uprate Project - August 2014 Section 2 2-32 Table 2.4-3. Comparison of Post-and Pre-Uprate Monthly Rainfall Totals TPM-1 Post-Uprate Pre-Uprate June 2013 - May 2014 June 2010 - May 2011 Month

  1. of Rain Days Amount (inches)
  1. of Rain Days Greater than 1 Inch Month
  1. of Rain Days Amount (inches)
  1. of Rain Days Greater than 1 Inch Jun-131 10 0.6 NA Jun-102 NA NA NA Jul-13 18 2.41 0

Jul-102 NA NA NA Aug-13 15 1.28 0

Aug-10 20 8.95 3

Sep-13 16 2.25 0

Sep-10 24 13.49 4

Oct-13 11 1.35 0

Oct-10 13 2.32 0

Nov-13 11 2.14 0

Nov-10 12 5.5 1

Dec-13 13 0.34 0

Dec-10 6

0.54 0

Jan-14 12 0.63 0

Jan-11 8

3.53 1

Feb-14 7

0.5 0

Feb-11 6

0.24 0

Mar-14 17 0.99 0

Mar-11 11 1.64 0

Apr-14 19 0.18 0

Apr-11 8

1.85 1

May-14 19 0.31 0

May-11 27 2.4 0

TOTALS (Aug-May) 12.39 0

40.46 Notes:

1 Rainfall data was missing from 6/11/2013 through 6/26/2013 as a result of the unit repair.

2 Unit became operational on 7/26/10.

Key:

NA - Not available since the system was not yet in operation or was under repair.

FPL Turkey Point Annual Post-Uprate Monitoring Report for Units 3 & 4 Uprate Project - August 2014 Section 2 2-33 Table 2.4-4. Monthly Rainfall in and around the CCS Month NEXRAD1 (inches)

TPM-1 (inches)

LU-South (inches)

S-20 Gauge (inches)

Homestead Air Force (inches)

Month NEXRAD1 (inches)

TPM-1 (inches)

LU-South (inches)

S-20 Gauge (inches)

Homestead Air Force (inches)

Aug-10 NA 8.95 NA 8.76 6.94 Jul-12 5.14 8.74 9.35 13.17 11.38 Sep-10 13.15 13.49 NA 15.70 11.67 Aug-12 6.94 12.53 9.21 9.27 15.86 Oct-10 2.40 2.32 NA 2.77 2.62 Sep-12 5.00 6.98 8.95 12.18 9.43 Nov-10 4.39 5.50 6.12 3.11 3.37 Oct-12 2.44 4.87 3.63 4.44 5.88 Dec-10 0.69 0.54 1.00 0.72 0.47 Nov-12 0.27 1.32 0.69 0.81 1.65 Jan-11 3.32 3.53 2.81 4.57 4.03 Dec-12 0.32 0.64 0.46 0.55 0.63 Feb-11 0.10 0.24 0.11 0.08 0.12 Jan-13 0.18 0.31 0.52 0.41 0.26 Mar-11 1.24 1.64 1.13 1.19 1.23 Feb-13 0.85 1.23 1.42 1.15 0.96 Apr-11 1.65 1.85 0.06 0.92 1.09 Mar-13 0.93 1.26 1.06 1.25 2.16 May-11 1.13 2.40 0.37 1.23 1.12 Apr-13 3.89 3.45 4.84 6.38 5.92 Jun-11 1.35 2.93 0.42 2.17 2.67 May-13 8.59 3.08 7.68 14.54 15.60 Jul-11 7.68 10.64 8.47 5.87 5.59 Jun-13 3.15 0.6 4.05 5.06 6.63 Aug-11 6.52 9.24 6.32 3.04 9.55 Jul-13 8.31 2.41 8.61 8.60 10.27 Sep-11 6.19 6.93 4.95 8.6 4.66 Aug-13 4.47 1.28 6.40 3.07 1.88 Oct-11 8.84 13.25 14.5 7.78 12.27 Sep-13 4.41 2.25 5.74 4.68 6.31 Nov-11 0.23 0.32 0.61 1.12 0.74 Oct-13 1.28 1.35 2.47 1.32 1.09 Dec-11 0.33 0.56 1.32 0.43 0.28 Nov-13 5.42 2.14 5.71 4.81 3.67 Jan-12 0.45 1.45 0.92 0.30 0.06 Dec-13 0.78 0.341 2.58 2.97 2.50 Feb-12 5.60 5.94 5.42 5.82 6.37 Jan-14 1.47 0.633 1.87 3.00 3.28 Mar-12 0.45 0.98 1.25 2.18 2.57 Feb-14 1.67 0.505 1.82 2.58 2.25 Apr-12 8.45 12.49 11.69 7.07 10.64 Mar-14 1.18 0.993 1.42 1.75 1.65 May-12 7.26 9.41 4.39 9.90 9.85 Apr-14 0.40 0.182 0.99 0.31 0.35 Jun-12 5.21 8.90 NA 6

10.73 May-14 1.30 0.313 1.75 2.00 1.90 Notes:

1 NEXRAD data provided by SFWMD.

2 Data were missing from 6/11/2013 through 6/26/2013 as a result of unit repair.

Key:

LU = Land Utilization.

NEXRAD = Next generation radar.

TPM = Turkey Point Meteorological.

FPL Turkey Point Annual Post-Uprate Monitoring Report for Units 3 & 4 Uprate Project - August 2014 Section 2 FIGURES

FPL Turkey Point Annual Post-Uprate Monitoring Report for Units 3 & 4 Uprate Project-August 2014 Typical automated probe and cable.

Figure 2.1-1. Automated Groundwater Stations.

2-35 Section2 Biscayne Bay station.

FPL Turkey Point Annual Post-Uprate Monitoring Report for Units 3 & 4 Uprate Project - August 2014 Section 2 e

~

Cl)

CJ c:

Ill -

CJ

J "C

c:

0

(.)

CJ

!E CJ Cl)

Q.

CJ')

100000 ~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~

90000 80000 70000 60000 50000 40000 30000 20000 10000

,.r-

0 -!--------------------------------------------- 28 27 26 25 24

,__~~~~~~~~~~~~~~___.,_~~~~~~~~~~----.~~~~~~~~---- 23 6/1/10 9/1/10 1211/10 3/1/11 6/1/11 9/1/11 1211/11 3/1112 6/1112 9/1/12 1211112 3/1/13 6/1/13 9/1/13 1211/13 3/1/14 6/1/14 c::::::J Interim Operating Period -- Shallow Intermediate -- Deep Figure 2.1-2. TPGW-1 Specific Conductance and Temperature.

2-36

(.)

~

Cl)...

J -

Ill...

Cl)

Q.

E Cl)

FPL Turkey Point Annual Post-Uprate Monitoring Report for Units 3 & 4 Uprate Project - August 2014 Section 2 100000 90000 E

CJ -

en 80000 2:

Q)

~ -. -JP\\

CJ 70000 c:

n:J 60000 CJ

J "C

50000 c:

0 0

CJ 40000 i;:::

  • i:;

30000 Q) c.

en 20000 10000 0

28 27 0

0 26 -

Q)...

J -

n:J...

Q) 25

c.

E Q)

I-24 1------~------------------------__.,----~------+ 23 611110 911110 1211110 311/11 6/1111 911/11 1211/11 3/1112 611112 911112 1211112 311113 611113 911113 1211113 311/14 611/14 c::::J Interim Operating Period

-- Shallow Intermediate -- Deep Figure 2.1-3. TPGW-2 Specific Conductance and Temperature.

2-37

FPL Turkey Point Annual Post-Uprate Monitoring Report for Units 3 & 4 Uprate Project - August 2014 Section 2 100000 e 90000

(,) -"'

80000 Cl) 70000

(,)

c:

-~

Ill 60000 r--r--

I

(,)

J "C

50000 c:

0 (J

(,)

40000 It=

'(j Cl) 30000 Q.

20000 10000 0

28 27 -

(J 26

~

Cl)...

J -

Ill...

Cl) 25 Q.

E Cl) 24

,__~~~~~~~~~~~~~~___.,_~~~~~~~~~~----.~~~~~~~~---- 23 6/1/10 9/1/10 1211/10 3/1/11 6/1/11 9/1/11 1211/11 3/1112 6/1112 9/1/12 1211112 3/1/13 6/1/13 9/1/13 1211/13 3/1/14 6/1/14 c::::::J Interim Operating Period -- Shallow Intermediate -- Deep Figure 2.1-4. TPGW-3 Specific Conductance and Temperature.

2-38

FPL Turkey Point Annual Post-Uprate Monitoring Report for Units 3 & 4 Uprate Project - August 2014 Section 2 e

(,) -"'

2::

Cl)

(,) c:

Ill -

(,)

J "C c:

0

(.)

(,)

!E

(,)

Cl)

Q.

100000 90000 80000 70000 60000 50000 40000

    • I 30000 20000 10000 0

28 27 26 25 24 23 6/1/10 9/1/10 1211/10 3/1/11 6/1/11 9/1/11 1211/11 3/1112 6/1112 9/1/12 1211112 3/1/13 6/1/13 9/1/13 1211/13 3/1/14 6/1/14 c::::::J Interim Operating Period -- Shallow Intermediate -- Deep Figure 2.1-5. TPGW-4 Specific Conductance and Temperature.

2-39

(.)

~

Cl)...

J -

Ill...

Cl)

Q.

E Cl)

I-

FPL Turkey Point Annual Post-Uprate Monitoring Report for Units 3 & 4 Uprate Project - August 2014 Section 2 100000 e 90000

(,) -"'

80000 2::

Cl) 70000

(,) c:

Ill 60000

(,)

s "C

50000 c:

0 (J

(,)

40000

!E 30000

,~

(,)

Cl) a.

20000 10000 0

28 27 -

(J 26

~

Cl)...

s -

Ill...

Cl) 25

a.

E Cl)

I-24 o--~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~---

23 6/1/10 9/1/10 1211/10 3/1/11 6/1/11 9/1/11 1211/11 3/1112 6/1112 9/1/12 1211112 3/1/13 6/1/13 9/1/13 1211/13 3/1/14 6/1/14 c::::::J Interim Operating Period -- Shallow Intermediate -- Deep Figure 2.1-6. TPGW-5 Specific Conductance and Temperature.

2-40

FPL Turkey Point Annual Post-Uprate Monitoring Report for Units 3 & 4 Uprate Project - August 2014 Section 2 100000 e 90000

(,) -"'

80000 2::

Cl) 70000

(,) c:

Ill 60000

(,)

s "C

50000 c:

0 (J

(,)

40000 It=

'(j 30000 Cl) a.

20000 10000 0

28 27 -

(J 26

~

Cl)...

s -

Ill...

Cl) 25

a.

E Cl) 24 1--"""=--~--~-~-~~-~-~~-~-~~-~-~-------.:.--~-~--~---f-23 6/1/10 9/1/10 1211/10 3/1/11 6/1/11 9/1/11 1211/11 3/1112 6/1112 9/1/12 1211112 3/1/13 6/1/13 9/1/13 1211/13 3/1/14 6/1/14 c::::::J Interim Operating Period -- Shallow Intermediate -- Deep Figure 2.1-7. TPGW-6 Specific Conductance and Temperature.

2-41

FPL Turkey Point Annual Post-Uprate Monitoring Report for Units 3 & 4 Uprate Project - August 2014 Section 2 e

!,,) -

Cl).::

Cl)

!,,)

c:

Ill -

!,,)

J "C

c:

0

(.)

!,,)

!E

!,,)

Cl) a.

Cl) 5000 4500 4000 3500 3000 2500 2000 1500 1000 500 0

28 27 26 25 24 23 6/1/10 9/1/10 1211/10 3/1/11 6/1/11 9/1/11 1211/11 3/1112 6/1112 9/1/12 1211112 3/1/13 6/1/13 9/1/13 1211/13 3/1/14 6/1/14 c::::::J Interim Operating Period -- Shallow Intermediate -- Deep Figure 2.1-8. TPGW-7 Specific Conductance and Temperature.

2-42

(.)

~

Cl)...

J -

Ill...

Cl) a.

E Cl)

FPL Turkey Point Annual Post-Uprate Monitoring Report for Units 3 & 4 Uprate Project - August 2014 5000 e

4500

(,) -""

4000 2::

Q) 3500

(,) c:

11' 3000

(,)

J "C

2500 c:

0 0

(,)

2000

!e 1500

(,)

Q) a.

1000 500 r111 11 0

'm 11[ ll[llUI Section 2 27 0

0 26

-~

25

J 1a...

Q) a.

E Q) fo-i--~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~---+- 23 6/ 1/ 10 9/1/10 12/1/10 3/1/11 6/1/11 9/1/11 12/1/11 3/1/12 6/1/12 9/1/12 12/1/12 3/1/13 6/1/13 9/1/13 12/1/13 3/1/14 6/1/14 c::::J Interim Operating Period -- Shallow Intermediate -- Deep Figure 2.1-9. TPGW-8 Specific Conductance and Temperature.

2-43