TSD 14-004 Revision 1 Page 1 of 15

Summary of Changes in this Revision:

  • Rev. 1 -Changed Eu distribution coefficient values.

TSD 14-004 Revision 1 Page 2 of 15

RECOMMENDED VALUES FOR THE DISTRIBUTION COEFFICIENT (KD) TO BE USED IN DOSE ASSESSMENTS FOR DECOMMISSIONING THE ZION NUCLEAR POWER PLANT Terry Sullivan September 24, 2014 Revision 1 Informal Report Biological, Environmental & Climate Sciences Department Brookhaven National Laboratory P.O. Box 5000 Upton, NY 11973-5000 www.bnl.gov Notice: This manuscript has been authored by employees of Brookhaven Science Associates, LLC under Contract No. DE-AC02-98CH10886 with the U.S. Department of Energy. The publisher by accepting the manuscript for publication acknowledges that the United States Government retains a non-exclusive, paid-up, irrevocable, world-wide license to publish or reproduce the published form of this manuscript, or allow others to do so, for United States Government purposes.

TSD 14-004 Revision 1 Page 3 of 15 BNL-105442-2014-IR-R1

DISCLAIMER This report was prepared as an account of work sponsored by an agency of the United States Government. Neither the United States Government nor any agency thereof, nor any of their employees, nor any of their contractors, subcontractors, or their employees, makes any warranty, express or implied, or assumes any legal liability or responsibility for the accuracy, completeness, or any third partys use or the results of such use of any information, apparatus, product, or process disclosed, or represents that its use would not infringe privately owned rights.

Reference herein to any specific commercial product, process, or service by trade name, trademark, manufacturer, or otherwise, does not necessarily constitute or imply its endorsement, recommendation, or favoring by the United States Government or any agency thereof or its contractors or subcontractors. The views and opinions of authors expressed herein do not necessarily state or reflect those of the United States Government or any agency thereof.

TSD 14-004 Revision 1 Page 4 of 15

Table of Contents

1. Introduction................................................................................................................................ 1
2. Approach.................................................................................................................................... 2
3. Data............................................................................................................................................. 2

Concrete Environment Kd values............................................................................................... 4

4. Discussion.................................................................................................................................. 6
5. Recommended Values................................................................................................................ 7

References....................................................................................................................................... 9

List of Tables Table 1. Potential Radionuclides of Concern at the Zion Power Plant.......................................... 1

Table 2 Site-specific Kd values (ml/g) for the Zion Nuclear Power Station.................................. 3

Table 3 Literature soil Kd values for radionuclides of concern at Zion......................................... 4

Table 4 Preferred distribution coefficients (Kd ml/g) for cement concrete environments (Table 5.1 Krupka, 1998)........................................................................................................................... 6

Table 5 Recommended Kd values to be used in the basement fill model...................................... 8

TSD 14-004 Revision 1 Page 5 of 15

1

1. Introduction ZionSolutions is in the process of decommissioning the Zion Nuclear Power Plant. The site contains two reactor Containment Buildings, a Fuel Building, an Auxiliary Building, and a Turbine Building that may be contaminated. The current decommissioning plan involves removing all above grade structures to a depth of 3 feet below grade. The remaining underground structures will be backfilled. The remaining underground structures will contain low amounts of residual licensed radioactive material. An important component of the decommissioning process is the demonstration that any remaining activity will not cause a hypothetical individual to receive a dose in excess of 25 mrem/y as specified in 10CFR20 Subpart E.

The compliance assessment requires prediction of the release and transport of contaminants to the hypothetical individual. Characterization studies by ZionSolutions have identified the following nuclides as being of potential concern (Table 1).

Table 1. Potential Radionuclides of Concern at the Zion Power Plant Radionuclides

Radionuclides Radionuclides Radionuclides Radionuclides Radionuclides

H-3

Co-60

Tc-99

Cs-137

Eu-155

Pu-241

C-14

Ni-63

Ag-108m

Pm-147

Np-237

Am-241

Fe-55

Sr-90

Sb-125

Eu-152

Pu-238

Am-243

Ni-59

Nb-94

Cs-134

Eu-154

Pu-239/240

Cm-243/244

A key parameter in this assessment is the distribution coefficient (Kd) which is a measure of the amount of the radionuclide that will sorb to the solid media (soil or backfill) in the subsurface environment. The exposure pathway of concern is the groundwater. Groundwater concentration has an inverse relationship with Kd. Thus a lower value of Kd will provide higher groundwater concentrations and a more conservative prediction of dose. BNL (Yim, 2012, Milian, 2014) has conducted site-specific measurements on using local groundwater and samples of site soils and potential backfill materials to assess the Kd value for the contaminants with the expected highest residual concentration (Fe-55, Co-60, Ni-63, Sr-90, and Cs-137) for ZionSolutions. However, there are several other radioactive contaminants (Table 1) that may be present at lower levels that will still require assessment to demonstrate that dose limits are not exceeded. This document reviews the existing literature to recommend a value for Kd when site-specific numbers are not available.

Literature values for Kd show that sorption strongly depends on the contacting media and the geochemical conditions. The backfill selected for disposal will therefore play a huge role in determining the choice of the Kd value. A final decision has not been made on the backfill material at the Zion Power Plant. Materials under consideration include:

  • Crushed concrete demolition debris
  • Crushed cinder block
  • Local sand TSD 14-004 Revision 1 Page 6 of 15

2 The concrete and cinder block would be obtained from the building materials removed to three feet below grade and would be free from residual radioactive contamination. Combinations of the above materials are also under consideration.

The first three materials are alkaline and will cause the pH to rise substantially above the local ambient conditions. Based on testing at BNL with materials supplied by ZionSolutions, the pH will initially increase to 10 or 11 for the cementitious materials and grout. Eventually, as the alkali is consumed by buffering reactions the pH will decrease. This is expected to take a minimum of several hundred years depending on the flow rate and buffering capacity of the surrounding soils. Several studies have found that pH is a key geochemical factor in controlling sorption. For this reason consideration must be given to the likely high pH conditions when selecting the Kd value to be used in modeling if a mixture of backfills is used.

2. Approach The objective of selecting a Kd value is to choose a value that is reasonably conservative with respect to projected groundwater dose (radionuclide concentrations). This requires a value that is likely to provide a lower bound for Kd. The value for Kd strongly depends on the solid media that contacts the groundwater thus site-specific values are the most representative of actual conditions.

For radionuclides with site-specific data the media with the lowest measured Kd was selected to provide this lower bound. For radionuclides without site-specific data the literature was reviewed to determine the range of Kd values typically found in soils and found in cementitious (high pH) environments. These Kds will be used for initial DUST-MS runs to determine groundwater concentrations at potential well locations. Depending upon the outcome they may be further refined with more site specific or literature data.

Baes and Sharp (Baes and Sharp 1983) were among the first to show that the Kd value for Cs and Sr is log-normally distributed in soils. They applied a log-normal distribution to all elements and this approach is widely used (Sheppard and Thibault, 1990; NRC, 1990). Sheppard and Thibault extended the concept of log-normal distribution to apply to a soil type (sand, loam, clay or organic). This concept is used in this report to determine the 25th percentile value for Kd in soils. The use of the 25th percentile value has been performed in other decommissioning studies at Fermi (Dionne, 2009) and Humboldt Bay (Besson, 2013).

3. Data Three types of data are used for the selection of an appropriate Kd for the backfill region at the Zion Nuclear Power Plant. These include site-specific values using local groundwater and soil or concrete samples from the site; literature values for soil environments; and literature values for concrete environments.

Site-specific Kd data:

Kd measurements were performed for ZionSolutions using site-specific groundwater and soil samples (clay, silt, native sand, and disturbed sand - native sand that was excavated during TSD 14-004 Revision 1 Page 7 of 15

3 construction of the plant and backfilled around the plant) for six nuclides. Additionally potential backfill materials including two concrete samples (one from the Containment Building and one from the Crib House), two Cinder Block samples from the site, and one low density grout were tested using site-specific groundwater. The elements measured included Fe, Co, Ni, Sr and Cs.

Table 2 presents the results of these measurements. Note isotopes of Cs and Ni found in Table 1 are also presented in Table 2 as isotopes will have the same chemical sorption properties.

Table 2 Site-specific Kd values (ml/g) for the Zion Nuclear Power Station Radionuclide

Site

Specific

Silt Kd1

ml/g

Site

Specific

Silt

Clay1 Kd

ml/g

Site

Specific

Disturbed

Sand Kd1

ml/g

Site

Specific

Native

Sand Kd1

ml/g

Site Specific

Containment

Concrete1 Kd

ml/g

Site

Specific

Crib

House

Concrete1

Kd ml/g

Site

Specific

Cinder

Block

Kd2

ml/g

Site

Specific

Low

Density

Grout Kd2

ml/g

Fe-55

8061

17288

2857

5579

16546

17288

Ni-59

75

136

331

62

3438

8361

177

4,569

Co-60

1161

1161

1161

1161

1161

1161

223

1941

Ni-63

75

136

331

62

3438

8361

177

4,569

Sr-90

2.3

5.7

3.4

2.3

10.4

18.5

23.5

11.8

Cs-134

527

3011

635

615

85

45

249

303

Cs-137

527

3011

635

615

85

45

249

303

1 Yim, 2012 2 Milian, 2014 Literature values for Kd in soil environments Numerous measurements of Kd have been reported in the literature. Key compilations of this data include those by Baes and Sharp (Baes, 1983); Sheppard and Thibault (Sheppard, 1990), Yu (Yu, 1993), the U.S. Nuclear Regulatory Commission (NRC, 2000); and the International Atomic Energy Agency (IAEA, 2010). All of these documents provide statistical parameters to estimate the distribution. Literature values for Kd in soil media from selected sources are presented in Table 3. The first two columns are mean values for Kd presented in (Yu, 1993 and IAEA 2012). For conservatism the 25th percentile in the distribution from the reports (Sheppard, 1990 and NRC, 2000) are also reported in the Table 3. For the Sheppard data the log-normal distribution of the data for sand was used except for Nb-94 and Sb-125 which are the geometrics means because standard deviations were not provided in the Sheppard data. Other soil types were not included because sand, in most cases, has the lowest Kd and the surrounding soil at Zion is primarily sand.

TSD 14-004 Revision 1 Page 8 of 15

4 Table 3 Literature soil Kd values for radionuclides of concern at Zion.

Radionuclide

(Yu, 1993) Sand

Kd

ml/g

(IAEA 2010)

Tables 12, 14 Sand or All

Soils ml/g

(NRC, 2000)

25th Percentile ml/g

(Sheppard, 1990)

Sand 25th

Percentile ml/g

H-3

1

0.0431

0.051

C-14

5

1.24

1.76

Fe-55

220

320

34.3

39

Ni-59

400

140

160

148

Co-60

60

640

42.9

9.2

Ni-63

400

140

160

148

Sr-90

15

22

7.49

4.6

Nb-94

160

170

44.6

164

Tc-99

0.1

0.23

0.0618

0.04

Ag-108m

90

52.6

27

Sb-125

45

17

43.4

45

Cs-134

280

530

92.5

51

Cs-137

280

530

93.4

51

Pm-147

450

94.8

Eu-152

96.2

Eu-154

95.2

Eu-155

95.8

Np-237

5

35

3.75

1.30

Pu-238

550

400

268

174

Pu-239/240

550

400

267.5

174

Pu-241

550

400

268

174

Am-241

1900

1000

177

333

Am-243

1900

1000

178

333

Cm-243/244

4000

9300

1990

891

The predictions at the 25th percent level of the distribution for the NRC and Sheppard reports are similar. This is because the NRC data set for the distribution is based on, but not limited to the Sheppard data set.

Concrete Environment Kd values The chemistry of the water will change from an initial value of greater than 11 down to the ambient pH in a crushed concrete environment. The convention of Bradbury and Sarott (1995) describing the three types of chemical environments that all cements progress through is used to understand the data. The following description of the environments has been abbreviated from the initial work by Krupka (Krupka, 1998)

TSD 14-004 Revision 1 Page 9 of 15

5

  • Environment I This environment occurs immediately after the cement hardens and is wetted by infiltrating water The cement pore water is characterized as having a high pH of >12.5, high ionic strength, and high concentrations of potassium and sodium resulting from the dissolution of alkali impurities in the clinker phases. Hydration is still continuing during Environment I with the formation of C-S-H (Calcium-Silicate -

Hydrate) and portlandite [Ca(OH)2] The composition of the cement pore fluid is at equilibrium with portlandite during this time. Based on the modeling estimates this environment may last for the first 100 to 10,000 years.

Environment II During this period, the soluble salts of the alkali metals are all dissolved The pH of the cement pore water is controlled at a value of about 12.5 by the solubility of portlandite. The C-S-H and portlandite are the major solid phases present Environment II may last for a long time Its duration depends on how much water percolates through the system to dissolve all the slightly soluble portlandite This environment may last from 100-10,000 years to 1,000-100,000 years.

Environment III The concentration of portlandite has been reduced to such an extent by this period that the solubility of C-S-H now controls the pH of the cement pore fluid The C-S-H starts to dissolve incongruently with a continual decrease in pH At the end of this evolution, Environment III can be conceptualized as leaving only silica (SiO2) as the solubility control for the pore fluid pH. For the sake of simplicity, the final end point of Environment III can be considered somewhat analogous to the geochemical conditions of the "normal" ambient soil environment.

The important point of this discussion is that the cement will control the pH for hundreds to thousands of years. Thus, if cementitious materials are used for backfill material, a high pH environment will prevail and Kd values are likely to be similar to those found in cement based materials.

TSD 14-004 Revision 1 Page 10 of 15

6 Table 4 Preferred distribution coefficients (Kd ml/g) for cement concrete environments (Table 5.1 Krupka, 1998).

Environment I Environment II Environment III Oxidizing Conditions Reducing Conditions Oxidizing Conditions Reducing Conditions Oxidizing Conditions Reducing Conditions Radionuclide Kd (ml/g)

Am 5000 5000 5000 5000 500 500 C

500 500 100 100 10 10 Cl 5

5 1

1 0

0 I

10 10 5

5 1

1 Lanthanides 5000 5000 5000 5000 500 500 Ni 100 100 100 100 10 10 Nb 1000 1000 1000 1000 100 100 Np 2000 5000 2000 5000 200 500 Pu 5000 5000 5000 5000 500 500 Ra 100 100 100 100 100 100 Sr 1

1 3

3 3

5 Tc 0

1000 0

1000 0

100 Th 5000 5000 5000 5000 500 500 U

1000 1000 1000 1000 100 100 The above table does not include Cs or Eu, two nuclides of potential concern at Zion. Cs is known to have low sorption on cements. This is due in part to competition for sorption sites with other ions (Na and K) that are released by the leaching from the concrete. Bradbury and Sarott (Bradbury 1995) provided Kd estimates for Cs as 2 to 20 ml/g with the low value in Environment I. This is lower than the site-specific value for Cs at Zion. They also provided estimates for Eu (5000 to 1000 ml/g) with Environment III with the lowest Kd and Cm (5000 to 1000 ml/g) with Environment III providing the least sorption (Bradbury, 1995). A recent study (Felipe-Sotello, 2012) measured Kd values for Eu at 66000 ml/g. Other values for distribution coefficients in cementitious materials are provided in (Kaplan, 2008).

4. Discussion Site-specific values are the most representative of the conditions that will occur at Zion after decommissioning and they will be recommended for use in groundwater dose assessment.

Although a final determination of the backfill material has not been made, it is likely that the backfill will contain a substantial amount of cementitious material. Examining the representative Kd values for soils (Table 3) and cementitious systems (Table 4) it is clear that with the exception of Cs the cement Kd values are greater than for soil systems. The Kd value selected is meant to provide a conservative assessment of dose to the groundwater pathway. For this reason, with the exception of H and Tc literature soil Kd values will be recommended for the assessment when site-specific values are not available. To increase the degree of confidence TSD 14-004 Revision 1 Page 11 of 15

7 that a conservative value has been selected the 25th percentile Kd from either the NRC or Sheppard reports will be used. For Tc the sand Kd in Table 3 is less than 0.1. The cementitious oxidizing conditions Kd is zero in Table 4. The soil Kd is rounded to zero to ensure conservatism.

The same will be done for the Table 3 H Kd as a conservative assumption.

For one nuclide, Sb-125, the IAEA median value was lower than the 25th percentile value on the NRC distribution. No standard deviation was reported in the Sheppard data. For this reason, the IAEA value is recommended as the appropriate value for screening calculations for Sb-125.

The Eu isotopes all have slightly different Kd values in Table 3. These values are from NRC, 2000 and are calculated values for the 25th percentile based on a mean value and standard deviation. One would expect isotopes to have the same sorption characteristics. It is likely that this is round-off error in determining the 25th percentile. For this reason the minimum value for all three isotopes will be selected as the reference value.

The recommended values for the basement fill model are either site-specific or values measured in soil. The Kd values in a cement environment for elements other tan Cs, Tc and H are expected to be higher based on existing data. Thus, they should be appropriate for outside of the buildings in the surrounding soil with the exception of H, Tc and Cs. Depending on the buffering capacity of the soil, time, and distance from the building, the chemical environment of the groundwater exiting the building may control the sorption of Cs. For this reason, the site-specific Kd for Cs in the cement environment should be used in the surrounding soils to provide a conservative estimate of groundwater concentration for dose assessment.

5. Recommended Values The values in Table 5 are the minimum values found in any test for the site-specific case and the minimum values found from the reports cited in Table 3. These values are appropriate for maximizing the groundwater concentration and thereby predicted dose. For intruder scenarios or scenarios where the backfill is used as gardening soils, a higher value of Kd would be recommended for maximizing the predicted dose in those cases.

TSD 14-004 Revision 1 Page 12 of 15

8 Table 5 Recommended Kd values to be used in the basement fill model.

Radionuclide

Half Life

(years)

Recommended

Basement Fill

Kd ml/g

Reference1

H-3

1.24E+01

0 2

C-14

5.73E+03

1.2 NRC, 2000 Fe-55

2.70E+00

2857 Site-Specific Ni-59

7.50E+04

62 Site Specific Co-60

5.27E+00

223 Site Specific Ni-63

9.60E+01

62 Site Specific Sr-90

2.91E+01

2.3 Site Specific Nb-94

2.03E+04

45 NRC, 2000 Tc-99

2.13E+05

0 2

Ag-108m

1.27E+02

27 Sheppard, 1990 Sb-125

2.77E+00

17 IAEA, 2010 Cs-134

2.06E+00

45 Site Specific Cs-137

3.00E+01

45 Site Specific Pm-147

2.62E+00

95 NRC, 2000 Eu-152

1.33E+01

953 NRC, 2000 Eu-154

8.80E+00

95 NRC, 2000 Eu-155

4.96E+00

95 NRC, 2000 Np-237

2.14E+06

1 Sheppard, 1990 Pu-238

8.77E+01

174 Sheppard, 1990 Pu-239/240

2.41E+04

174 Sheppard, 1990 Pu-241

1.44E+01

174 Sheppard, 1990 Am-241

4.32E+02

177 NRC, 2000 Am-243

7.38E+03

177 NRC, 2000 Cm-243/244

2.85E+01

891 Sheppard, 1990 1 Values from NRC, 2000 or Sheppard, 1990 are the 25th percentile values on the cumulative distribution function.

2 25th percentile value was less than 0.1 and was rounded down to 0.

3 25th percentile value was less listed as 96 in Table 3. It was changed to 95 to make it consistent with other Eu isotopes.

TSD 14-004 Revision 1 Page 13 of 15

9 References Baes, C.F., and R.D. Sharp, (1983). A proposal for Estimation of Sol Leaching and Leaching Constants for Use in Assessment Models, J. Environ. Qual., Vol. 12, No. 1, 1983. Pp 17-28.

Besson, J.W. (2013). Humboldt Bay Power Plant License Termination Plan Revision 0 Chapter 6 Compliance with the Radiological Criteria May 2013, ENG-HB-003, Rev 0. Bartlett, Plymouth, MA.

Dionne, B.J., (2009). Calculation of Enrico Fermi 1 Derived Concentration Guideline Levels for Soil, ENG 004, Rev 1., Bartlett, Plymouth, MA Environmental Protection Agency, (2004). Understanding Variation in Partition Coefficient, Kd Values, United States Office of Air and Radiation EPA 402-R-04-002C, Vol 1 - 3.

Felipe-Sotelo, M., Hinchliff, J., Evans, N., Warwick, P. and Read, D. (2012). Sorption of radionuclides to a cementitious backfill material under near-field conditions, Mineralogical Magazine, December 2012, Vol. 76(8), pp. 3401-3410.

International Atomic Energy Agency (IAEA, 2010). handbook of Parameter Values for the Prediction of Radionuclide Transfer in Terrestrial and Freshwater Environments, Technical Report Series No. 472., International Atomic Energy Agency, Vienna, Austria.

Kaplan, D.J. Roberts, K., Coates, J., Sigegried, M., and Serkiz, S., 2008.Saltstone and concrete interactions with radionuclides sorption (Kd), desorption, and reduction capacity measurements, SRNS-STI-2008-00045, Savannah River National laboratory, Savannah River, SC.

Kay, J.A. (2004). Yankee Nuclear Plant Station License Termination Plan, Yankee Atomic Electric Company, MA.

Krupka, K. M. and R. J. Serne. (1998). Effects on Radionuclide Concentrations by Cement/Ground-Water Interactions in Support of Performance Assessment of Low-Level Radioactive Waste Disposal Facilities. NUREG/CR-6377 (PNNL-11408), Pacific Northwest, National Laboratory, Richland, Washington.

Milian, L., T. Sullivan (2014). Sorption (Kd) measurements on Cinder Block and Grout in Support of Dose Assessments for Zion Nuclear Station Decommissioning, Brookhaven National Laboratory Report to ZionSolutions, April 2014 (Draft).

Ochs, M., Pointeau, I. and Giffaut, E. (2006). Caesium sorption by hydrated cement as a function of degradation state: Experiments and modelling. Waste Management, 26, 725_732.

Sheppard, M. and Thibault, D.H., 1990. Default Soil Solid/Liquid Partition Coefficients, Kds, For Four Major Soil types: A Compendium, Health Physics, Vol. 59, No. 4, pp. 471-481, Oct, 1990.

TSD 14-004 Revision 1 Page 14 of 15

10 U.S. Nuclear Regulatory Commission, (NRC, 2000). Development of Probabilistic RESRAD 6.0 and RESRADBUILD 3.0 Computer Codes, NUREG/CR-6697, U.S. Nuclear Regulatory Commission, December 2000.

U.S. Department of Energy West Valley Demonstration Project, (DOE, 2009). Phase 1 Decommissioning Plan for the West Valley Demonstration, Appendix C Rev 2., Department of Energy.

Yim, S.P, T.M. Sullivan, and L. Milian, Sorption (Kd) measurements in Support of Dose Assessments for Zion Nuclear Station Decommissioning, Brookhaven National Laboratory Report to ZionSolutions, December 12, 2012.

Yu, C., Loureiro, C., Cheng, J.-J., Jones, Y.Y., Wang, Y.P. Chia, and E. Faillace, (1993). Data Collection Handbook to Support Modeling the Impacts of Radioactive Material in Soil, ANL/EAIS-8, Argonne National Laboratory, Argonne, IL.

TSD 14-004 Revision 1 Page 15 of 15

TSD 14-004 Revision 1 Page 1 of 15

Summary of Changes in this Revision:

  • Rev. 1 -Changed Eu distribution coefficient values.

TSD 14-004 Revision 1 Page 2 of 15

RECOMMENDED VALUES FOR THE DISTRIBUTION COEFFICIENT (KD) TO BE USED IN DOSE ASSESSMENTS FOR DECOMMISSIONING THE ZION NUCLEAR POWER PLANT Terry Sullivan September 24, 2014 Revision 1 Informal Report Biological, Environmental & Climate Sciences Department Brookhaven National Laboratory P.O. Box 5000 Upton, NY 11973-5000 www.bnl.gov Notice: This manuscript has been authored by employees of Brookhaven Science Associates, LLC under Contract No. DE-AC02-98CH10886 with the U.S. Department of Energy. The publisher by accepting the manuscript for publication acknowledges that the United States Government retains a non-exclusive, paid-up, irrevocable, world-wide license to publish or reproduce the published form of this manuscript, or allow others to do so, for United States Government purposes.

TSD 14-004 Revision 1 Page 3 of 15 BNL-105442-2014-IR-R1

DISCLAIMER This report was prepared as an account of work sponsored by an agency of the United States Government. Neither the United States Government nor any agency thereof, nor any of their employees, nor any of their contractors, subcontractors, or their employees, makes any warranty, express or implied, or assumes any legal liability or responsibility for the accuracy, completeness, or any third partys use or the results of such use of any information, apparatus, product, or process disclosed, or represents that its use would not infringe privately owned rights.

Reference herein to any specific commercial product, process, or service by trade name, trademark, manufacturer, or otherwise, does not necessarily constitute or imply its endorsement, recommendation, or favoring by the United States Government or any agency thereof or its contractors or subcontractors. The views and opinions of authors expressed herein do not necessarily state or reflect those of the United States Government or any agency thereof.

TSD 14-004 Revision 1 Page 4 of 15

Table of Contents

1. Introduction................................................................................................................................ 1
2. Approach.................................................................................................................................... 2
3. Data............................................................................................................................................. 2

Concrete Environment Kd values............................................................................................... 4

4. Discussion.................................................................................................................................. 6
5. Recommended Values................................................................................................................ 7

References....................................................................................................................................... 9

List of Tables Table 1. Potential Radionuclides of Concern at the Zion Power Plant.......................................... 1

Table 2 Site-specific Kd values (ml/g) for the Zion Nuclear Power Station.................................. 3

Table 3 Literature soil Kd values for radionuclides of concern at Zion......................................... 4

Table 4 Preferred distribution coefficients (Kd ml/g) for cement concrete environments (Table 5.1 Krupka, 1998)........................................................................................................................... 6

Table 5 Recommended Kd values to be used in the basement fill model...................................... 8

TSD 14-004 Revision 1 Page 5 of 15

1

1. Introduction ZionSolutions is in the process of decommissioning the Zion Nuclear Power Plant. The site contains two reactor Containment Buildings, a Fuel Building, an Auxiliary Building, and a Turbine Building that may be contaminated. The current decommissioning plan involves removing all above grade structures to a depth of 3 feet below grade. The remaining underground structures will be backfilled. The remaining underground structures will contain low amounts of residual licensed radioactive material. An important component of the decommissioning process is the demonstration that any remaining activity will not cause a hypothetical individual to receive a dose in excess of 25 mrem/y as specified in 10CFR20 Subpart E.

The compliance assessment requires prediction of the release and transport of contaminants to the hypothetical individual. Characterization studies by ZionSolutions have identified the following nuclides as being of potential concern (Table 1).

Table 1. Potential Radionuclides of Concern at the Zion Power Plant Radionuclides

Radionuclides Radionuclides Radionuclides Radionuclides Radionuclides

H-3

Co-60

Tc-99

Cs-137

Eu-155

Pu-241

C-14

Ni-63

Ag-108m

Pm-147

Np-237

Am-241

Fe-55

Sr-90

Sb-125

Eu-152

Pu-238

Am-243

Ni-59

Nb-94

Cs-134

Eu-154

Pu-239/240

Cm-243/244

A key parameter in this assessment is the distribution coefficient (Kd) which is a measure of the amount of the radionuclide that will sorb to the solid media (soil or backfill) in the subsurface environment. The exposure pathway of concern is the groundwater. Groundwater concentration has an inverse relationship with Kd. Thus a lower value of Kd will provide higher groundwater concentrations and a more conservative prediction of dose. BNL (Yim, 2012, Milian, 2014) has conducted site-specific measurements on using local groundwater and samples of site soils and potential backfill materials to assess the Kd value for the contaminants with the expected highest residual concentration (Fe-55, Co-60, Ni-63, Sr-90, and Cs-137) for ZionSolutions. However, there are several other radioactive contaminants (Table 1) that may be present at lower levels that will still require assessment to demonstrate that dose limits are not exceeded. This document reviews the existing literature to recommend a value for Kd when site-specific numbers are not available.

Literature values for Kd show that sorption strongly depends on the contacting media and the geochemical conditions. The backfill selected for disposal will therefore play a huge role in determining the choice of the Kd value. A final decision has not been made on the backfill material at the Zion Power Plant. Materials under consideration include:

  • Crushed concrete demolition debris
  • Crushed cinder block
  • Local sand TSD 14-004 Revision 1 Page 6 of 15

2 The concrete and cinder block would be obtained from the building materials removed to three feet below grade and would be free from residual radioactive contamination. Combinations of the above materials are also under consideration.

The first three materials are alkaline and will cause the pH to rise substantially above the local ambient conditions. Based on testing at BNL with materials supplied by ZionSolutions, the pH will initially increase to 10 or 11 for the cementitious materials and grout. Eventually, as the alkali is consumed by buffering reactions the pH will decrease. This is expected to take a minimum of several hundred years depending on the flow rate and buffering capacity of the surrounding soils. Several studies have found that pH is a key geochemical factor in controlling sorption. For this reason consideration must be given to the likely high pH conditions when selecting the Kd value to be used in modeling if a mixture of backfills is used.

2. Approach The objective of selecting a Kd value is to choose a value that is reasonably conservative with respect to projected groundwater dose (radionuclide concentrations). This requires a value that is likely to provide a lower bound for Kd. The value for Kd strongly depends on the solid media that contacts the groundwater thus site-specific values are the most representative of actual conditions.

For radionuclides with site-specific data the media with the lowest measured Kd was selected to provide this lower bound. For radionuclides without site-specific data the literature was reviewed to determine the range of Kd values typically found in soils and found in cementitious (high pH) environments. These Kds will be used for initial DUST-MS runs to determine groundwater concentrations at potential well locations. Depending upon the outcome they may be further refined with more site specific or literature data.

Baes and Sharp (Baes and Sharp 1983) were among the first to show that the Kd value for Cs and Sr is log-normally distributed in soils. They applied a log-normal distribution to all elements and this approach is widely used (Sheppard and Thibault, 1990; NRC, 1990). Sheppard and Thibault extended the concept of log-normal distribution to apply to a soil type (sand, loam, clay or organic). This concept is used in this report to determine the 25th percentile value for Kd in soils. The use of the 25th percentile value has been performed in other decommissioning studies at Fermi (Dionne, 2009) and Humboldt Bay (Besson, 2013).

3. Data Three types of data are used for the selection of an appropriate Kd for the backfill region at the Zion Nuclear Power Plant. These include site-specific values using local groundwater and soil or concrete samples from the site; literature values for soil environments; and literature values for concrete environments.

Site-specific Kd data:

Kd measurements were performed for ZionSolutions using site-specific groundwater and soil samples (clay, silt, native sand, and disturbed sand - native sand that was excavated during TSD 14-004 Revision 1 Page 7 of 15

3 construction of the plant and backfilled around the plant) for six nuclides. Additionally potential backfill materials including two concrete samples (one from the Containment Building and one from the Crib House), two Cinder Block samples from the site, and one low density grout were tested using site-specific groundwater. The elements measured included Fe, Co, Ni, Sr and Cs.

Table 2 presents the results of these measurements. Note isotopes of Cs and Ni found in Table 1 are also presented in Table 2 as isotopes will have the same chemical sorption properties.

Table 2 Site-specific Kd values (ml/g) for the Zion Nuclear Power Station Radionuclide

Site

Specific

Silt Kd1

ml/g

Site

Specific

Silt

Clay1 Kd

ml/g

Site

Specific

Disturbed

Sand Kd1

ml/g

Site

Specific

Native

Sand Kd1

ml/g

Site Specific

Containment

Concrete1 Kd

ml/g

Site

Specific

Crib

House

Concrete1

Kd ml/g

Site

Specific

Cinder

Block

Kd2

ml/g

Site

Specific

Low

Density

Grout Kd2

ml/g

Fe-55

8061

17288

2857

5579

16546

17288

Ni-59

75

136

331

62

3438

8361

177

4,569

Co-60

1161

1161

1161

1161

1161

1161

223

1941

Ni-63

75

136

331

62

3438

8361

177

4,569

Sr-90

2.3

5.7

3.4

2.3

10.4

18.5

23.5

11.8

Cs-134

527

3011

635

615

85

45

249

303

Cs-137

527

3011

635

615

85

45

249

303

1 Yim, 2012 2 Milian, 2014 Literature values for Kd in soil environments Numerous measurements of Kd have been reported in the literature. Key compilations of this data include those by Baes and Sharp (Baes, 1983); Sheppard and Thibault (Sheppard, 1990), Yu (Yu, 1993), the U.S. Nuclear Regulatory Commission (NRC, 2000); and the International Atomic Energy Agency (IAEA, 2010). All of these documents provide statistical parameters to estimate the distribution. Literature values for Kd in soil media from selected sources are presented in Table 3. The first two columns are mean values for Kd presented in (Yu, 1993 and IAEA 2012). For conservatism the 25th percentile in the distribution from the reports (Sheppard, 1990 and NRC, 2000) are also reported in the Table 3. For the Sheppard data the log-normal distribution of the data for sand was used except for Nb-94 and Sb-125 which are the geometrics means because standard deviations were not provided in the Sheppard data. Other soil types were not included because sand, in most cases, has the lowest Kd and the surrounding soil at Zion is primarily sand.

TSD 14-004 Revision 1 Page 8 of 15

4 Table 3 Literature soil Kd values for radionuclides of concern at Zion.

Radionuclide

(Yu, 1993) Sand

Kd

ml/g

(IAEA 2010)

Tables 12, 14 Sand or All

Soils ml/g

(NRC, 2000)

25th Percentile ml/g

(Sheppard, 1990)

Sand 25th

Percentile ml/g

H-3

1

0.0431

0.051

C-14

5

1.24

1.76

Fe-55

220

320

34.3

39

Ni-59

400

140

160

148

Co-60

60

640

42.9

9.2

Ni-63

400

140

160

148

Sr-90

15

22

7.49

4.6

Nb-94

160

170

44.6

164

Tc-99

0.1

0.23

0.0618

0.04

Ag-108m

90

52.6

27

Sb-125

45

17

43.4

45

Cs-134

280

530

92.5

51

Cs-137

280

530

93.4

51

Pm-147

450

94.8

Eu-152

96.2

Eu-154

95.2

Eu-155

95.8

Np-237

5

35

3.75

1.30

Pu-238

550

400

268

174

Pu-239/240

550

400

267.5

174

Pu-241

550

400

268

174

Am-241

1900

1000

177

333

Am-243

1900

1000

178

333

Cm-243/244

4000

9300

1990

891

The predictions at the 25th percent level of the distribution for the NRC and Sheppard reports are similar. This is because the NRC data set for the distribution is based on, but not limited to the Sheppard data set.

Concrete Environment Kd values The chemistry of the water will change from an initial value of greater than 11 down to the ambient pH in a crushed concrete environment. The convention of Bradbury and Sarott (1995) describing the three types of chemical environments that all cements progress through is used to understand the data. The following description of the environments has been abbreviated from the initial work by Krupka (Krupka, 1998)

TSD 14-004 Revision 1 Page 9 of 15

5

  • Environment I This environment occurs immediately after the cement hardens and is wetted by infiltrating water The cement pore water is characterized as having a high pH of >12.5, high ionic strength, and high concentrations of potassium and sodium resulting from the dissolution of alkali impurities in the clinker phases. Hydration is still continuing during Environment I with the formation of C-S-H (Calcium-Silicate -

Hydrate) and portlandite [Ca(OH)2] The composition of the cement pore fluid is at equilibrium with portlandite during this time. Based on the modeling estimates this environment may last for the first 100 to 10,000 years.

Environment II During this period, the soluble salts of the alkali metals are all dissolved The pH of the cement pore water is controlled at a value of about 12.5 by the solubility of portlandite. The C-S-H and portlandite are the major solid phases present Environment II may last for a long time Its duration depends on how much water percolates through the system to dissolve all the slightly soluble portlandite This environment may last from 100-10,000 years to 1,000-100,000 years.

Environment III The concentration of portlandite has been reduced to such an extent by this period that the solubility of C-S-H now controls the pH of the cement pore fluid The C-S-H starts to dissolve incongruently with a continual decrease in pH At the end of this evolution, Environment III can be conceptualized as leaving only silica (SiO2) as the solubility control for the pore fluid pH. For the sake of simplicity, the final end point of Environment III can be considered somewhat analogous to the geochemical conditions of the "normal" ambient soil environment.

The important point of this discussion is that the cement will control the pH for hundreds to thousands of years. Thus, if cementitious materials are used for backfill material, a high pH environment will prevail and Kd values are likely to be similar to those found in cement based materials.

TSD 14-004 Revision 1 Page 10 of 15

6 Table 4 Preferred distribution coefficients (Kd ml/g) for cement concrete environments (Table 5.1 Krupka, 1998).

Environment I Environment II Environment III Oxidizing Conditions Reducing Conditions Oxidizing Conditions Reducing Conditions Oxidizing Conditions Reducing Conditions Radionuclide Kd (ml/g)

Am 5000 5000 5000 5000 500 500 C

500 500 100 100 10 10 Cl 5

5 1

1 0

0 I

10 10 5

5 1

1 Lanthanides 5000 5000 5000 5000 500 500 Ni 100 100 100 100 10 10 Nb 1000 1000 1000 1000 100 100 Np 2000 5000 2000 5000 200 500 Pu 5000 5000 5000 5000 500 500 Ra 100 100 100 100 100 100 Sr 1

1 3

3 3

5 Tc 0

1000 0

1000 0

100 Th 5000 5000 5000 5000 500 500 U

1000 1000 1000 1000 100 100 The above table does not include Cs or Eu, two nuclides of potential concern at Zion. Cs is known to have low sorption on cements. This is due in part to competition for sorption sites with other ions (Na and K) that are released by the leaching from the concrete. Bradbury and Sarott (Bradbury 1995) provided Kd estimates for Cs as 2 to 20 ml/g with the low value in Environment I. This is lower than the site-specific value for Cs at Zion. They also provided estimates for Eu (5000 to 1000 ml/g) with Environment III with the lowest Kd and Cm (5000 to 1000 ml/g) with Environment III providing the least sorption (Bradbury, 1995). A recent study (Felipe-Sotello, 2012) measured Kd values for Eu at 66000 ml/g. Other values for distribution coefficients in cementitious materials are provided in (Kaplan, 2008).

4. Discussion Site-specific values are the most representative of the conditions that will occur at Zion after decommissioning and they will be recommended for use in groundwater dose assessment.

Although a final determination of the backfill material has not been made, it is likely that the backfill will contain a substantial amount of cementitious material. Examining the representative Kd values for soils (Table 3) and cementitious systems (Table 4) it is clear that with the exception of Cs the cement Kd values are greater than for soil systems. The Kd value selected is meant to provide a conservative assessment of dose to the groundwater pathway. For this reason, with the exception of H and Tc literature soil Kd values will be recommended for the assessment when site-specific values are not available. To increase the degree of confidence TSD 14-004 Revision 1 Page 11 of 15

7 that a conservative value has been selected the 25th percentile Kd from either the NRC or Sheppard reports will be used. For Tc the sand Kd in Table 3 is less than 0.1. The cementitious oxidizing conditions Kd is zero in Table 4. The soil Kd is rounded to zero to ensure conservatism.

The same will be done for the Table 3 H Kd as a conservative assumption.

For one nuclide, Sb-125, the IAEA median value was lower than the 25th percentile value on the NRC distribution. No standard deviation was reported in the Sheppard data. For this reason, the IAEA value is recommended as the appropriate value for screening calculations for Sb-125.

The Eu isotopes all have slightly different Kd values in Table 3. These values are from NRC, 2000 and are calculated values for the 25th percentile based on a mean value and standard deviation. One would expect isotopes to have the same sorption characteristics. It is likely that this is round-off error in determining the 25th percentile. For this reason the minimum value for all three isotopes will be selected as the reference value.

The recommended values for the basement fill model are either site-specific or values measured in soil. The Kd values in a cement environment for elements other tan Cs, Tc and H are expected to be higher based on existing data. Thus, they should be appropriate for outside of the buildings in the surrounding soil with the exception of H, Tc and Cs. Depending on the buffering capacity of the soil, time, and distance from the building, the chemical environment of the groundwater exiting the building may control the sorption of Cs. For this reason, the site-specific Kd for Cs in the cement environment should be used in the surrounding soils to provide a conservative estimate of groundwater concentration for dose assessment.

5. Recommended Values The values in Table 5 are the minimum values found in any test for the site-specific case and the minimum values found from the reports cited in Table 3. These values are appropriate for maximizing the groundwater concentration and thereby predicted dose. For intruder scenarios or scenarios where the backfill is used as gardening soils, a higher value of Kd would be recommended for maximizing the predicted dose in those cases.

TSD 14-004 Revision 1 Page 12 of 15

8 Table 5 Recommended Kd values to be used in the basement fill model.

Radionuclide

Half Life

(years)

Recommended

Basement Fill

Kd ml/g

Reference1

H-3

1.24E+01

0 2

C-14

5.73E+03

1.2 NRC, 2000 Fe-55

2.70E+00

2857 Site-Specific Ni-59

7.50E+04

62 Site Specific Co-60

5.27E+00

223 Site Specific Ni-63

9.60E+01

62 Site Specific Sr-90

2.91E+01

2.3 Site Specific Nb-94

2.03E+04

45 NRC, 2000 Tc-99

2.13E+05

0 2

Ag-108m

1.27E+02

27 Sheppard, 1990 Sb-125

2.77E+00

17 IAEA, 2010 Cs-134

2.06E+00

45 Site Specific Cs-137

3.00E+01

45 Site Specific Pm-147

2.62E+00

95 NRC, 2000 Eu-152

1.33E+01

953 NRC, 2000 Eu-154

8.80E+00

95 NRC, 2000 Eu-155

4.96E+00

95 NRC, 2000 Np-237

2.14E+06

1 Sheppard, 1990 Pu-238

8.77E+01

174 Sheppard, 1990 Pu-239/240

2.41E+04

174 Sheppard, 1990 Pu-241

1.44E+01

174 Sheppard, 1990 Am-241

4.32E+02

177 NRC, 2000 Am-243

7.38E+03

177 NRC, 2000 Cm-243/244

2.85E+01

891 Sheppard, 1990 1 Values from NRC, 2000 or Sheppard, 1990 are the 25th percentile values on the cumulative distribution function.

2 25th percentile value was less than 0.1 and was rounded down to 0.

3 25th percentile value was less listed as 96 in Table 3. It was changed to 95 to make it consistent with other Eu isotopes.

TSD 14-004 Revision 1 Page 13 of 15

9 References Baes, C.F., and R.D. Sharp, (1983). A proposal for Estimation of Sol Leaching and Leaching Constants for Use in Assessment Models, J. Environ. Qual., Vol. 12, No. 1, 1983. Pp 17-28.

Besson, J.W. (2013). Humboldt Bay Power Plant License Termination Plan Revision 0 Chapter 6 Compliance with the Radiological Criteria May 2013, ENG-HB-003, Rev 0. Bartlett, Plymouth, MA.

Dionne, B.J., (2009). Calculation of Enrico Fermi 1 Derived Concentration Guideline Levels for Soil, ENG 004, Rev 1., Bartlett, Plymouth, MA Environmental Protection Agency, (2004). Understanding Variation in Partition Coefficient, Kd Values, United States Office of Air and Radiation EPA 402-R-04-002C, Vol 1 - 3.

Felipe-Sotelo, M., Hinchliff, J., Evans, N., Warwick, P. and Read, D. (2012). Sorption of radionuclides to a cementitious backfill material under near-field conditions, Mineralogical Magazine, December 2012, Vol. 76(8), pp. 3401-3410.

International Atomic Energy Agency (IAEA, 2010). handbook of Parameter Values for the Prediction of Radionuclide Transfer in Terrestrial and Freshwater Environments, Technical Report Series No. 472., International Atomic Energy Agency, Vienna, Austria.

Kaplan, D.J. Roberts, K., Coates, J., Sigegried, M., and Serkiz, S., 2008.Saltstone and concrete interactions with radionuclides sorption (Kd), desorption, and reduction capacity measurements, SRNS-STI-2008-00045, Savannah River National laboratory, Savannah River, SC.

Kay, J.A. (2004). Yankee Nuclear Plant Station License Termination Plan, Yankee Atomic Electric Company, MA.

Krupka, K. M. and R. J. Serne. (1998). Effects on Radionuclide Concentrations by Cement/Ground-Water Interactions in Support of Performance Assessment of Low-Level Radioactive Waste Disposal Facilities. NUREG/CR-6377 (PNNL-11408), Pacific Northwest, National Laboratory, Richland, Washington.

Milian, L., T. Sullivan (2014). Sorption (Kd) measurements on Cinder Block and Grout in Support of Dose Assessments for Zion Nuclear Station Decommissioning, Brookhaven National Laboratory Report to ZionSolutions, April 2014 (Draft).

Ochs, M., Pointeau, I. and Giffaut, E. (2006). Caesium sorption by hydrated cement as a function of degradation state: Experiments and modelling. Waste Management, 26, 725_732.

Sheppard, M. and Thibault, D.H., 1990. Default Soil Solid/Liquid Partition Coefficients, Kds, For Four Major Soil types: A Compendium, Health Physics, Vol. 59, No. 4, pp. 471-481, Oct, 1990.

TSD 14-004 Revision 1 Page 14 of 15

10 U.S. Nuclear Regulatory Commission, (NRC, 2000). Development of Probabilistic RESRAD 6.0 and RESRADBUILD 3.0 Computer Codes, NUREG/CR-6697, U.S. Nuclear Regulatory Commission, December 2000.

U.S. Department of Energy West Valley Demonstration Project, (DOE, 2009). Phase 1 Decommissioning Plan for the West Valley Demonstration, Appendix C Rev 2., Department of Energy.

Yim, S.P, T.M. Sullivan, and L. Milian, Sorption (Kd) measurements in Support of Dose Assessments for Zion Nuclear Station Decommissioning, Brookhaven National Laboratory Report to ZionSolutions, December 12, 2012.

Yu, C., Loureiro, C., Cheng, J.-J., Jones, Y.Y., Wang, Y.P. Chia, and E. Faillace, (1993). Data Collection Handbook to Support Modeling the Impacts of Radioactive Material in Soil, ANL/EAIS-8, Argonne National Laboratory, Argonne, IL.