ES-401 PWR Examination Outline Form ES-401-2 Facility: Millstone 3 Date of Exam: September 23rd, 2015 RO KJ A Category Points SRO-Only Points Tier Group K
K K
K K
K A A A A G A2 G*
Total 1
2 3
4 5
6 1
2 3
4 Total
- 1.
Emergency &
1 5
2 2
4 3
2 18 1
5 6
Abnormal Plant 2
1 2
2 NIA 2
1 NIA 1
9 1
3 4
Evolutions Tier Totals 6
4 4
6 4
3 27 2
8 10
- 2.
1 2
3 3
2 3
2 1
2 3
5 2
28 3
2 5
Plant Systems 2
1 0
0 2
0 1
1 2
0 0
3 10 1
2 3
Tier 3
3 3
4 3
3 2
4 3
5 5
38 4
4 8
Totals
- 3.
Generic Knowledge and 1
2 3
4 1
2 3
4 Abilities Categories 10 7
4 3
1 2
1 3
1 2
Note:
- 1.
Ensure that at least two topics from every applicable KIA category are sampled within each tier of the RO and SRO-only outlines (i.e., except for one category in Tier 3 of the SRO-only outline, the "Tier Totals" in each Kl A category shall not be less than two). (One Tier 3 Radiation Control KA is allowed if the Kl A is replaced by a Kl A from another Tier 3 Category).
- 2.
The point total for each group and tier in the proposed outline must match that specified in the table. The final point total for each group and tier may deviate by+/- 1 from that specified in the table based on NRC revisions. The final RO exam must total 75 points and the SRO-only exam must total 25 points.
- 3.
Systems/evolutions within each group are identified on the associated outline; systems or evolutions that do not apply at the facility should be deleted and justified; operationally important, site-specific systems/evolutions that are not included on the outline should be added. Refer to Section D of ES-401 for guidance regarding the elimination of inappropriate KIA statements.
- 4.
Select topics from as many systems and evolutions as possible; sample every system or evolution in the group before selecting as second topic for any system or evolution.
- 5.
Absent a plant-specific priority, only those Kl As having an importance rating (IR) of 2.5 or higher shall be selected. Use the RO and SRO ratings for the RO and SRO-only portions, respectively.
- 6.
Select SRO topics for Tiers 1 and 2 from the shaded systems and Kl A categories.
- 7.
- The generic (G) K/As in Tiers I and 2 shall be selected from Section 2 of the KIA Catalog, but the topics must be relevant to the applicable evolution or system. Refer to Section D. I.b ofES-401 for the applicable K/As.
- 8.
On the following pages, enter the Kl A numbers, a brief description of each topic, the topics' importance ratings (IRs) for the applicable license level, and the point totals(#) for each system and category. Enter the group and tier totals for each category in the table above; if fuel handling equipment is sampled in a category other than Category A2 or G* on the SRO-only exam, enter it on the left side of Column A2 for Tier 2, Group 2 (Note #1 does not apply). Use duplicate pages for RO and SRO-only exams.
- 9.
For Tier 3, select topics from Section 2 of the KIA catalog, and enter the KIA numbers, descriptions, IRs, and point totals(#) on Form ES-401-3. Limit SRO selections to K/As that are linked to IOCFR55.43.
G*
Generic KJ As
ES-401 2
Form ES-401-2 ES-40I PWR Examination Outline Form ES-40I-2 Emergency and Abnormal Plant Evolutions - Tier I/Group I (RO)
E/APE #I Name I Safety K
K K
A A
G KIA Topic(s)
IR Function I
2 3
I 2
000007 Reactor Trip -
Operate I monitor Nuclear Instrumentation Stabilization - Recovery I 1 5
on a reactor trip 4.0/4.1 1
0000008 Pressurizer Vapor Interrelations between vapor space break Space Accident I 3 2
and sensors and detectors 2.7/2.7 2
000009 Small Break LOCA Operational implications of the use of steam 13 2
tables on a small break LOCA 3.5/4.2 3
OOOOI l Large Break LOCA Determine or interpret equipment necessary I 3 7
for critical pump water seals during LOCA 3.2/3.4 4
OOOOI5/17 RCP Operational Implications of thermodynamic Malfunctions I 4 4
relationship between RCS loops and SGs 2.9/3.l 5
000022 Loss of Rx Coolant Ability to perform without reference actions Makeup I 2 2.4.49 that require immediate operation 4.6/4.4 6
000025 Loss of RHR Determine or interpret limitations on LPI System/ 4 5
flow and temperature rates of change 3.1/3.5 7
000027 Pressurizer Pressure Knowledge ofEOP entry conditions and Control Malfunction I 3 2.4.1 immediate action steps 4.6/4.8 8
000029 A TWS I 1 15 Operate I monitor AFW system 4.1/3.9 9
000038 Steam Gen. Tube Operate I monitor safety injection and Rupture I 3 30 containment isolation systems on SGTR 4.0/3.8 10 000056 Loss of Off-site Operational implications of the principle of Power I 6 1
cooling by natural convection 3.7/4.2 11 000057 Loss of Vital AC Determine or interpret AC instrument bus Elec. Inst. Bus I 6 6
alarms for the inverter and alternate source 3.2/3.7 12 000062 Loss of Nuclear Operate I monitor control of flow rates to Service Water I 4 6
components cooled by the SWS 2.912.9 13 000065 Loss of Instrument Reasons for: Knowing effects on plant Air I 8 3
operation of isolating equipment from air 2.9/3.4 14 W /E04 LOCA Outside Operational implications of annunciators, Containment I 3 3
indicating signals, and remedial actions 3.5/3.9 15 W /EI I Loss of Emergency Operational implications of components, Coolant Recirc. I 4 1
capacity, & function of emergency systems 3.7/4.0 I6 W/E05 Loss of Secondary Reasons for normal, abnormal and Heat Sink I 4 2
emergency operating procedures 3.7/4.1 I7 000077 Generator Voltage Interrelations between Generator Voltage and Electric Grid I
and Grid Disturbances and motors 3.1/3.2 18 Disturbances I 6 KIA Category Totals:
5 2
2 4
3 2
Group Point Total:
18
ES-401 3
Form ES-401-2 ES-401 PWR Examination Outline Form ES-401-2 Emergency and Abnormal Plant Evolutions - Tier I/Group 2 (RO)
E/APE #I Name I Safety K
K K
A A
G KIA Topic(s)
IR Function 1
2 3
1 2
000003 Dropped Control Reasons for reset of demand position counter Rod I 1 6
to zero 2.7/3.0 19 000032 Loss of Source Operate I monitor manual restoration of Range NI I 7 1
power 3.1/3.4 20 000061 ARM System Operational Implications of detector Alarms I 7 1
limitations 2.512.9 21 000076 High Reactor Reasons for corrective actions as a result of Coolant Activity I 9 5
high RCS fission-product activity level 2.9/3.6 22 Interrelations between SI Termination and W/E02 SI Termination I 3 2
heat removal systems and relation to proper 3.5/3.9 23 operation of the facility W IE 13 Steam Generator Determine or interpret facility conditions Over-pressure I 4 1
and selection of annropriate procedures 2.9/3.4 24 W /E03 Post LOCA Interrelations between control and safety Cooldown Depress. I 4 I
systems, instruments, signals, interlocks, 3.6/4.0 25 failure modes, auto/manual features W/E09 Natural Circ. I 4 Operate I monitor for desired operating 3
results during natural circulation operations 3.5/3.8 26 W /E08 RCS Overcooling -
Ability to recognize abnormal indications for PTS/4 2.4.4 system operating parameters that are entry 4.5/4.7 27 level conditions for EOPs and AOPs KIA Category Point Totals:
1 2
2 2
I I
Group Point Total:
9
ES-401 4
Form ES-401-2 ES-401 PWR Examination Outline Form ES-401-2 Plant Systems - Tier 2/Group I (RO)
System# I Name K
K K
K K
K A
A A
A G
KIA Topic(s)
IR 1
2 3
4 5
6 1
2 3
4 003 Reactor Physical connections I cause-effect Coolant Pump 10 relationship between RCPs and RCS 3.0/3.2 28 003 Reactor Manually operate I monitor seal Coolant Pump 1
injection in the control room 3.3/3.2 29 004 Chemical Manually operate I monitor boron and Volume 1
and control rod reactivity effects in 3.8/3.9 30 Control the control room 005 Residual Effect of a loss of malfunction of Heat Removal 1
RHR on the RCS 3.914.0 31 006 Emergency Effect ofloss or malfunction of Core Cooling 10 valves will have on ECCS 2.6/2.8 32 007 Pressurizer Operational implications of the Relief/Quench 2
method of forming a steam bubble in 3.1/3.4 33 Tank the Pzr 008 Component 2
Knowledge of bus power supplies to Cooling Water the CCW pump, including backup 3.0/3.2 34 008 Component Design features I interlocks for the Cooling Water 9
standby CCW pumps 2.7/2.9 35 010 Pressurizer Operational implications of constant Pressure Control 2
enthalpy expansion through a valve 2.6/3.0 36 012 Reactor Knowledge of bus power supplies to Protection I
RPS channels, components, and 3.3/3.7 37 interconnections 012 Reactor Effect of loss or malfunction of Protection 4
bypass-block circuits on RPS 3.3/3.6 38 013 Engineered 2
Predict impact I mitigate excess Safety Features steam demand 4.3/4.5 39 Actuation 022 Containment Knowledge of abnormal condition Cooling 2.4.11 procedures 4.0/4.2 40 026 Containment Effect of a loss of malfunction of Spray 2
CSS will have on recirc spray system 4.2/4.3 41 039 Main and Monitor automatic operation of Reheat Steam 2
isolation of the MRSS 3.1/3.5 42
ES-401 4
Form ES-401-2 ES-401 PWR Examination Outline Form ES-401-2 Plant Svstems - Tier 2/Group 1 (RO) Continued System# I Name K
K K
K K
K A
A A
A G
KIA Topic(s)
IR 1
2 3
4 5
6 1
2 3
4 059 Main Design features I interlocks which Feedwater 5
control speed of MFW pump turbine 2.5/2.8 43 059 Main Predict I monitor parameters Feedwater 7
associated with operating controls for 2.512.6 44 feed oump speed 061 Auxiliary/
Operational implications of decay Emergency 2
Feedwater heat sources and magnitude 3.213.6 45 062AC Manually operate I monitor all Electrical 1
breakers (including switchyard) in 3.3/3.l 46 Distribution the control room 062AC Predict impact I mitigate improper Electrical 3
sequencing when transferring to or 2.913.4 47 Distribution from an inverter 063 DC Monitor automatic operation of Electrical 1
meters, annunciators, and indicating 2.7/3.1 48 Distribution lights 064 Emergency Monitor automatic operation of:
Diesel Generator 4
number of starts available with an air 3.113.5 49 compressor 073 Process Effect of a loss of malfunction of Radiation 1
PRMS on radioactive effluent 3.614.2 50 Monitoring releases 076 Service Knowledge of bus power supplies to Water 1
service water 2.7/2.7 51 076 Service Manually operate I monitor SWS Water 2
valves in the control room 2.612.6 52 078 Instrument Knowledge of how AOPs are used in Air 2.4.8 coniunction with EOPs 3.8/4.5 53 078 Instrument Physical connections I cause-effect Air 4
relationship between IAS and cooling 2.612.9 54 water to the compressor 103 Containment Manually operate I monitor ESF 3
slave relays in the control room 2.7/2.7 55 Kl A Category Point Totals:
2 3
3 2
3 2
1 2
3 5
2 Group Point Total:
28
ES-401 5
Form ES-401-2 ES-401 PWR Examination Outline Form ES-401-2 Plant Systems - Tier 2/Group 2 (RO)
System# I Name K
K K
K K
K A
A A
A G
KIA Topic(s)
IR 1
2 3
4 5
6 1
2 3
4 016 N on-nucle<!r Parameters and logic used to assess Instrumentation 2.4.21 the status of safety functions, such as 4.014.6 56 core cooling, heat removal, integrity 017 In-Core Effect of loss or malfunction of ITM Temperature 1
sensors and detectors 2.7/3.0 57 Monitor 027 Containment Predict impact I mitigate high Iodine Removal 1
temperature in the filter system 3.0/3.3 58 029 Containment Design features I interlocks which Purge 2
provides for negative pressure in 2.9/3.1 59 containment 035 Steam Physical connections I cause-effect Generator 13 relationship between SGS and 2.7/2.8 60 condensate system 071 Waste Gas Predict impact I mitigate use of waste Disposal 2
gas release monitors, radiation, gas 3.3/3.6 61 flow rate, and totalizer 072 Area Predict I monitor parameters Radiation 1
associated with operating ARM 3.4/3.6 62 Monitoring controls including radiation levels 075 Circulating Design features I interlocks which Water 1
provide for heat sink 2.5/2.8 63 079 Station Air Ability to interpret and execute 2.1.20 procedure steps 4.6/4.6 64 086 Fire Events related to system operation Protection 2.4.30 that must be reported to internal 2.7/4.1 65 organizations, or external agencies KIA Category Point Totals:
1 0
0 2
0 1
1 2
0 0
3 Group Point Total:
10
ES-401 2
Form ES-401-2 ES-401 PWR Examination Outline Form ES-401-2 Emergency and Abnormal Plant Evolutions - Tier I/Group I (SRO)
E/ APE # I Name I Safety K
K K
A A
G KIA Topic(s)
IR Function I
2 3
I 2
000011 Large Break Recognize abnormal indications that are entry level LOCAi 3 2.4.4 conditions that are entry level for EOPs and AOPs 4.7 76 000015/17 RCP Knowledge of operational implications of EOP Malfunctions I 4 2.4.20 warnings, cautions, and notes 4.3 77 000029 ATWS I I I
Determine or interpret reactor nuclear instrumentation 4.7 78 000056 Loss of Off-site Knowledge ofEOP entry conditions and immediate Power I 6 2.4.1 action steps 4.8 79 000057 Loss of Vital AC Knowledge of operational implications of EOP Elec. Inst. Bus I 6 2.4.20 warnings, cautions, and notes 4.3 80 W /E05 Loss of Ability to prioritize and interpret the significance of Secondary Heat Sink I 4 2.4.45 each annunciator or alarm 4.3 81 KIA Category Totals:
I 5
Group Point Total:
6
ES-401 3
Form ES-401-2 ES-401 PWR Examination Outline Form ES-401-2 Emergency and Abnormal Plant Evolutions - Tier I/Group 2 (SRO)
E/APE #I Name I Safety K
K K
A A
G KIA Topic(s)
IR Function 1
2 3
1 2
Ability to interpret reference materials 000061 ARM System Alarms I 7 2.1.25 such as graphs, curves, tables, etc.
4.2 82 000076 High Reactor Coolant Ability to evaluate plant performance Activity I 9 2.1.7 and make operational judgments 4.7 83 Site Priority: AOP 3571 Selection of or adherence to Instrument Failure Response 1
appropriate procedures NA 84 Site Priority: AOP3578 Knowledge of low power/shutdown Inadvertent CIA 2.4.9 implications in accident mitigation 4.2 85 KIA Category Point Totals:
1 3
Group Point Total:
4
ES-401 4
Form ES-401-2 ES-401 PWR Examination Outline Form ES-401-2 Plant S JStems - Tier 2/Group 1 (SRO)
System# I Name K
K K
K K
K A
A A
A G
KIA Topic(s)
IR 1
2 3
4 5
6 1
2 3
4 004 Chemical and Volume Knowledge of specific Control 2.4.18 bases for EOPs 4.0 86 Predict impact and 005 Residual Heat Removal 4
mitigate RHR valve 2.9 87 malfunction 006 Emergency Core Ability to evaluate plant Cooling 2.1.7 performance and make 4.7 88 operational judgments 007 Pressurizer Predict impact and Relief/Quench Tank 2
mitigate abnormal 3.2 89 pressure in the PRT 073 Process Radiation Predict impact and Monitoring I
mitigate erratic or failed 2.9 90 power suooly KIA Category Point Totals:
3 2
Group Point Total:
5
ES-401 5
Form ES-401-2 ES-401 PWR Examination Outline Form ES-401-2 Plant Systems - Tier 2/Group 2 (SRO)
System# I Name K
K K
K K
K A
A A
A G
KIA Topic(s)
IR 1
2 3
4 5
6 1
2 3
4 Predict impact and mitigate rod 001 Control Rod Drive 17 misalignment alarm 3.8 91 016 Non-nuclear Prioritize and interpret the Instrumentation 2.4.45 significance of each 4.3 92 annunciator or alarm Knowledge of the bases in 035 Steam Generator 2.2.25 Technical Specifications for 4.2 93 LCOs and safety limits 1
2 Group Point Total:
3
ES-401 Generic Knowledge and Abilities Outline (Tier 3)
Form ES-401-3 Facility: Millstone Unit 3 Date of Exam: Sept 23, 2015 Category KIA#
Topic RO SRO-Only IR IR 2.1.28 Knowledge of purpose and function of major system components and 4.1 66 4.1 controls
- 1.
2.1.30 Ability to locate and operate components, including local controls 4.4 67 4.0 Conduct of 2.1.32 Ability to explain and apply system limits and precautions 3.8 68 4.0 Operations 2.1.42 Knowledge of new and spent fuel movement procedures 2.5 69 3.4 2.1.45 Ability to identify and interpret diverse indications to validate the response 4.3 94 of another indication Subtotal 4
.;yicr.",.,,
1
- 2.
2.2.2 Ability to manipulate the console controls as required to operate the facility 4.6 70 4.1 between shutdown and designated power levels Equipment 2.2.12 Knowledge of surveillance procedures 3.7 71 4.1 Control 2.2.37 Ability to determine operability and/or availability of safety related 3.6 72 4.6 equipment Knowledge of the process for managing maintenance activates during 2.2.17 power operations, such as risk assessments, work prioritization, and 3.8 95 coordination with the transmission system operator 2.2.20 Knowledge of the process for managing troubleshooting activities 3.8 96 2.2.38 Knowledge of conditions and limits in the facility license 4.5 97 Subtotal 3
}'.;%1,,~~~;
3
- 3.
Ability to use radiation monitoring systems, such as fixed radiation 2.3.5 monitors and alarms, portable survey instruments, personnel monitoring 2.9 73 2.9 equipment, etc.
Radiation Knowledge of radiological safety procedures pertaining to licensed 2.3.13 operator duties, such as rad monitor alarms, Ctmt entry requirements, fuel 3.8 98 handling responsibilities, access to locked high rad areas, etc.
Subtotal 1
,,JM;~~'<
1
- 4.
2.4.13 Knowledge of crew roles and responsibilities during EOP usage 4.0 74 4.6 Emergency 2.4.19 Knowledge ofEOP layout, symbols, and icons 3.4 75 4.1 Procedures/
2.4.1 Knowledge of EOP entry conditions and immediate action steps 4.8 99 Plan 2.4.26 Knowledge of facility protection requirements, including fire brigade and 3.6 100 portable firefighting equipment usage Subtotal 2
2
\\
"cc'>_,-'
Tier 3 Point Total 10 7
ES-401 Record of Rejected K/As Form ES-401-4 Tier I Randomly Reason for Rejection Group Selected Kl A 111 APE.015/017.Kl.1 Oversample of natural circulation, with APE.056.Kl.Oland W/E09.Al.03 112 APE.003.AK3.03 NA MP3. No automatic turbine runback to balance primary and secondary power 112 APE.076.AK2.01 NA MP3. No failed fuel Radiation Monitor. MP3 relies on manual sampling 2/1 003.A4.07 NA MP3. No RCP Seal Bypass path 2/1 004.A4.20 NA MP3. MP3 uses manual valves to align the de-borating demineralizer 2/1 008.K4.07 Oversample of CCW pump power supply, with 008.K2.02 211 010.K5.01 Oversample of steam table use, with EPE.009.Kl.2 2/1 012.Al.01 NA MP3. Operators do not monitor or adjust RPS trip setpoints 211 064.A3.08 NA MP3. No automatic transfer to auto position after manual EDG stop 211 073.K5.01 Oversample of Rad Monitors, with APE.061.Kl.Ol, 073.K3.01, 071.A2.02, 072.Al.01, SRO 073.A2.01 2/1 078.GEN.2.1. l 9 Ability to use PPC to evaluate system status; better tested on operating exam.
Information available for instrument air on the PPC is fairly generic. Candidates will be routinely demonstrating PPC use during the operating exam.
2/1 078.GEN.2.2.37 Determine operability of safety related equipment. Instrument air is not safety related 2/1 078.GEN.2.2.39
< 1 hour1.157407e-5 days <br />2.777778e-4 hours <br />1.653439e-6 weeks <br />3.805e-7 months <br /> Tech Spec LCOs. NA for instrument air 2/1 078.GEN.2.4. l 8 Basis of EOPs. EOPs assume no IAS available. No significant EOP bases step related to Instrument Air.
212 071.A2.07 NA MP3. No actions required with Gaseous Waste System on loss of Met Tower 212 079.GEN.2.2.37 Determine operability of safety related equipment. Station air is not safety related 314 GEN.2.4.28 Security procedures are not an RO job function SRO 111 EPE.O 11.GEN.2.2.39
< 1 hour1.157407e-5 days <br />2.777778e-4 hours <br />1.653439e-6 weeks <br />3.805e-7 months <br /> Tech Spec LCOs is RO level knowledge SRO 112 APE.061.GEN. 2.2.39
< 1 hour1.157407e-5 days <br />2.777778e-4 hours <br />1.653439e-6 weeks <br />3.805e-7 months <br /> Tech Spec LCOs is RO level knowledge SRO 112 Plant Priority Inadvertent CIA Over-sample of Critical Safety Function Status Trees GEN.2.4.21 SRO 2/2 001.A2.2 Effect of loss of power to reactor trip breakers is RO level knowledge SRO 2/2 001.A2.10 Effect of loss of power to Rod Drive MG Sets is RO level knowledge ES-401, Page 27of33
ES-301 Administrative Topics Outline Form ES-301-1 Facility:
Millstone Unit 3 Date of examination:
9/14/15 Examination Level:
RO 0 SRO D Operating Test Number:
2K15 Administrative Topic (see Note)
Type Describe activity to be performed Code*
Perform AC electrical source inoperability Conduct of Operations surveillance requirements.
D,S K/A 2.1.31 (Ability to locate control room switches, controls, and RO A.1.1 indications, and to determine that they correctly reflect the desired plant lineup.)
KIA Rating: 4.6 I 4.3 Determine the required boration time and final control Conduct of Operations M, R rod height for a rapid downpower.
RO A.1.2 K/A 2.1.20 (Ability to interpret and execute procedure steps.)
K/A Rating: 4.6 I 4.6 Equipment Control Recommend a clearance boundary for 3CCl*P1 A.
P, D, R KIA 2.2.13 (Knowledge of tagging and clearance procedures.)
ROA.2 KIA Rating: 4.1 I 4.3 Make preparations required to remove a radiation monitor from service.
Radiation Control D,R K/A 2.3.5 (Ability to use radiation monitoring systems, such as ROA.3 fixed radiation monitors and alarms, portable survey instruments, personnel monitoring equipment, etc.)
KIA Rating: 2.9 I 2.9 Emergency Plan NOTE: All items (five total) are required for SROs. RO applicants require only four items unless they are retaking only the administrative topics (which would require all five items).
- Type Codes & Criteria:
(C)ontrol room, (S)imulator, or Class(R)oom (O)irect from bank ( s3 for ROs; s4 for SROs & RO retakes)
(N)ew or (M)odified from bank ( ;;::-:1)
(P)revious 2 exams ( s1; randomly selected)
ES-301, Page 22 of 27
ES-301 Administrative Topics Outline Form ES-301-1 Facility:
Millstone Unit 3 Date of examination:
9114/15 Examination Level:
Operating Test Number:
2K15 Administrative Topic (see Note)
Type Describe activity to be performed Code*
Loss of containment closure.
Conduct of Operations D,R KIA 2.1.36 (Knowledge of procedures and limitations involved in SRO A1.1 core alterations.)
K/A Rating: 3. 0 I 4.1 Review and approve reactivity calculation.
Conduct of Operations P,M,R KIA 2.1.37 (Knowledge of procedures, guidelines, or limitations SRO A1.2 associated with reactivity management.)
KIA Rating: 4.3 I 4.6 Notifications and reportability associated with a safety limit violation.
Equipment Control D,R KIA 2.2.22 (Knowledge of limiting conditions for operations and SRO A.2 safety limits.)
KIA Rating: 4.0 I 4.7 Review and approve a radioactive liquid waste Radiation Control discharge permit.
M,R SRO A.3 K/A 2.3.6 (Ability to approve release permits.)
KIA Rating: 2.0 / 3.8 Emergency plan classification and protective action recommendation for a general emergency.
Emergency Plan Kl A 2.4.41 (Knowledge of the emergency action level thresholds D, R and classifications.)
SRO A.4 K/A Rating: 2.9 I 4.6 K/A 2.4.44 (Knowledge of emergency plan protective action recommendations.)
K/A Rating: 2.4 I 4.4 NOTE: All items (five total) are required for SROs. RO applicants require only four items unless they are retaking only the administrative topics (which would require all five items).
- Type Codes & Criteria:
(C)ontrol room, (S)imulator, or Class(R)oom (D)irect from bank ( :::;3 for ROs; :::;4 for SROs & RO retakes)
(N)ew or (M)odified from bank ( :::::1)
(P)revious 2 exams ( :::;1; randomly selected)
ES-301, Page 22 of 27
Controi Roomiin-Piant Systems Outiine Form ES-301-2 Rev 0/1 Facility Millstone Unit 3 Date of Examination:
9/14/15 Exam Level:
RO [KJ SRO-I D SRO-U D Operating Test No.:
2K15 Control Room Systems:* 8 for RO; 7 for SRO-I; 2 or 3 for SRO-U System I JPM Title Type Code*
Safety Function
- a.
Perform A Boration At Power D, S 1-004 K/A Number: 004-A4.03; K/A Rating: 2. 7 I 3.2
- b. Vent Unisolated Accumulators K/A Number: 006-A1.13; K/A Rating: 3.5 I 3.7 M, EN,A,E,S 2-006 K/A Number: 006-A4.07; K/A Ratinq: 4.4 I 4.4
- c.
Arm COPPS M, S 3-010 K/A Number: 01 O-K4.03; K/A Rating: 3.8 I 4.1
- d. Aligning RHR For SOR Inventory Control P,D, L, S 4.1-005 K/A Number: 005-A4.01; KIA Rating: 3.6 / 3.4
- e. Natural Circulation Cooldown Using GA-26 P,D,EN,A, E,S 4.2 - 039 K/A Number: 039-A 1.05; K/A Rating: 3.2* I 3.3
- f.
Respond To An Inadvertent Containment Isolation Phase 'A' P, M, EN, A, E, 5-103 K/A Number: 103-A2.03; K/A Rating: 3.5/ 3.8 s
- g. Transferring Bus 340 To Offsite Power M, L,S 6-062 K/A Number: 062-A2.12; K/A Rating: 3.2 I 3.6
- h.
Stop Auxiliary Building Filtration (Lower Levels)
N, S 9-071 K/A Number: APE 060-AA1.02; K/A Rating: 2.9 I 3.1 In-Plant Systems* (3 for RO); (3 for SRO-I); (3 or 2 for SRO-U)
- i.
Local Actions On A Loss Of Instrument Air M,A,E 8-078 K/A Number: APE 065-AA1.04; KIA Rating: 3.5 I 3.4
- j.
Align ESF And Auxiliary Building Sump Pumps, Post LOCA D,A, E, R 6-062 K/A Number: 062-A4.04; K/A Rating: 2.6 I 2.7
- k.
Cross-Connect Service Water To East Switchgear Ventilation D, E, L 4.2 - 076 K/A Number: 076-K1.19; K/A Rating: 3.6 I 3.7 All RO and SRO-I control room (and in-plant) systems must be different and serve different safety functions; all five SRO-U systems must serve different safety functions; in-plant systems and functions may overlap those tested in the control room.
- Type Codes Criteria for RO I SRO-I / SRO-U (A)lternate path 4-6 I 4-6 I 2-3 (C)ontrol room (D)irect from bank s,g I s,8 I -:;;;,4 (E)mergency or abnormal in-plant 21 I 21 I ;:::1 (EN)gineered safety feature
~ I ~ I 21 (control room system)
(L)ow-Power I Shutdown 21 I 21 I ;:::1 (N)ew or (M)odified from bank including 1 (A) 221 22 I ;:::1 (P)revious 2 exams
-:;;;.3 I s,3 I -:;;;.2 (randomly selected)
(R)CA 21 I 21 I ;:::1 (S)imulator ES-301, Page 23 of 27
ES-301 Controi Roomiin-Piant Systems Outiine Form ES-301 *2 Rev 0/1 Facility Millstone Unit 3 Date of Examination:
9/14/15 Exam Level:
ROD SRO-I [KJ SRO-U D Operating Test No.:
2K15 Control Room Systems:* 8 for RO; 7 for SRO-I; 2 or 3 for SRO-U System I JPM Title Type Code*
Safety Function
- a. Perform A Boration At Power D,S 1 - 004 KIA Number: 004-A4.03; KIA Rating: 2.7 13.2
- b. Vent Unisolated Accumulators KIA Number: 006-A 1.13; KIA Rating: 3.513.7 M, EN, A, E, S 2-006 KIA Number: 006-A4.07; KIA Ralina: 4.4 I 4.4
- c.
Arm COPPS M,S 3 - 010 KIA Number: 01 O-K4.03; KIA Rating: 3.8 I 4.1
- d. Aligning RHR For SDR Inventory Control P, D, L, S 4.1-005 KIA Number: 005-A4.01; KIA Rating: 3.613.4
- e.
Natural Circulation Cooldown Using GA-26 P, D, EN,A,E,S 4.2- 039 KIA Number: 039-A 1.05; KIA Rating: 3.2* 13.3
- f.
Respond To An Inadvertent Containment Isolation Phase 'A' P, M, EN, A, E, 5 -103 KIA Number: 103-A2.03; KIA Rating: 3.51 3.8 s
- g.
- h. Stop Auxiliary Building Filtration (Lower Levels)
N,S 9 - 071 I
KIA Number: APE 060-AA 1.02; KIA Rating: 2.9 I 3.1 In-Plant Systems* (3 for RO); (3 for SRO-I); (3 or 2 for SRO-U)
- i.
Local Actions On A Loss Of Instrument Air M,A,E 8- 078 K/A Number: APE 065-AA1.04; K/A Rating: 3.513.4
- j.
Align ESF And Auxiliary Building Sump Pumps, Post LOCA D,A, E,R 6-062 K/A Number: 062-A4.04; KIA Rating: 2.612.7
- k.
Cross-connect Service Water To East Switchgear Ventilation D,E, L 4.2-076 KIA Number: 076-K1.19; KIA Rating: 3.6 I 3. 7 All RO and SRO-I control room (and in-plant) systems must be different and serve different safety functions; all five SRO-U systems must serve different safety functions; in-plant systems and functions may overlap those tested in the control room.
- Type Codes Criteria for RO I SRO-I I SRO-U (A)lternate path 4-6 I 4-6 I 2-3 (C)ontrol room (D)irect from bank s9/ s8/ s4 (E)mergency or abnormal in-plant 21 I 21 I 21 (EN)gineered safety feature
- '! I ~ I 21 (control room system)
(L)ow-Power I Shutdown 21 / 21 I 21 (N)ew or (M)odified from bank including 1 (A) 22 I 22 I 21 (P)revious 2 exams s3 I :<;;;3 I :<;;;2 (randomly selected)
(R)CA 21 / 21 I 21 (S)imulator ES-301, Page 23 of 27
Appendix D Scenario Outline Form ES-D-1 Rev 0/1 Facility: Millstone 3 Scenario No.: 2K15 NRC-01 Op-Test No.: 2K15 Examiners:
Operators:
Initial Conditions: IC-357, 74% Power, Beginning of Life Turnover:
The last shift gerformed a downgower to 74% gower due to intake conditions.
AOP 3569, Severe Weather, has been entered for a hurricane watch. Additionally, last shift 12erformed OP 3301 G to induce gressurizer s12rays. The 'B' Stator Cooling Pum12 is out of service for bearing re12lacement. Orders are to maintain gower stable as management evaluates hurricane tracking.
Event Malf.
Event Event No.
No Type*
Description 1
RX10A I (RO)
Primary Pressurizer Level control channel TIS (US)
(RCS*L T459) fails high causing level to decrease (AOP 3571 ). (Tech Spec entrv) 2 R(RO)
Due to hurricane tracking, Management directs N (BOP) downpower to 60%@ 1% per minute (AOP 3575).
R (US) 3 RX19 I (BOP) 3FWS-PT508 fails high requiring manual control of the Master Speed Controller (AOP 3571 ).
4 ED04C C (RO)
Loss of emergency bus 34C. Isolate letdown TIS (US)
(AOP 3581 ). Recover from loss of 34C (AOP 3577).
(Tech Spec entrv) 5 EG01 M (RO)
A main generator trip occurs, causing a steam line MS02C M (BOP) break outside of containment, upstream of 'C' MSIV.
MS07A M (US)
On the plant trip, the 'C' & 'D' MSIV's fail open and the MS07B
'A' & 'B' low set SG safety valves fail open. All four MS12C SG's are faulted (ECA-2.1 ). Later in event, one SIG MS12D safety reseats (will transition to E-2).
6 FW20C C (BOP)
No Aux Feed Pumps auto start. The Turbine Driven FW18B Aux Feed Pump can be started from MBS.
7 SIR14 C(RO)
Charging injection valve (3SIH*MV8801 B) fails to open below P-19 requiring actions to open.
N)ormal, R)eactivitv, (I )nstrument, ( C)om ponent, (M)ajor D-37
SECTION 3 EXAM OVERVIEW "Title:
Four Faulted SG's New Scenario ID Number:
2K15 NRC-01 Revision:
- 1. The crew takes the shift with the plant at 74% power due to intake conditions. Last shift performed a downpower and entered AOP 3569, Severe Weather, for a hurricane watch. Last shift also performed OP 3301 G section 4.5 "Induce Pressurizer Spray to Equalize Boron Concentration". Additionally, the 'B' Stator Cooling Pump is out of service for a bearing replacement. The crew has direction to maintain power stable as Management evaluates hurricane tracking.
Event 1: The primary pressurizer level control channel (RCS*LT459) will fail high, causing the charging flow control valve to reduce flow, pressurizer level will lower. The RO will place the charging flow control valve in manual and correct charging flow. The US will enter AOP 3571, Instrument Failure Response. The crew will swap control channels and direct l&C to trip bistables. The US will refer to and enter Technical Specification 3.3.1 Action 6 (FU# 11 ). The US will review Technical Specifications 3.3.3.5 and 3.3.3.6 and Technical Requirement 7.4.1 Event 2: Based on hurricane tracking, Station management will direct a downpower to 60% at 1 % per minute. The crew will enter AOP 3575, Rapid Downpower, and perform the downpower.
Event 3: 3FWS-PT508 "Feed Header Pressure Transmitter" will fail high requiring the BOP to take manual control of the feedwater master speed controller. Once the plant is stable the crew will enter and complete actions in AOP 3571, Instrument Failure Response.
Event 4: The 'A' train emergency bus, 34C, will become faulted (&unrecoverable). The RO will perform immediate actions of AOP 3581, Immediate Actions, to simultaneously close the letdown orifice isolation valves and the charging flow control valve. The US will enter AOP 3581, confirm immediate actions are complete, and transition to AOP 3577, Loss of Normal and Offsite Power to a 4kv Emergency Bus, and perform multiple, time critical actions to keep the plant on-line. The following Technical Specifications are in effect; 3.8.1.1 Action a, 3.8.2.1, 3.8.3.1. The following Technical Requirements are in effect: 7.4.1, 7.6.1.
Event 5: After the crew has stabilized the plant, a Main Generator trip will occur causing an automatic Reactor trip. A steam line break will occur outside of containment, upstream of 'C' MSIV. The 'C' & 'D' MSIV's fail open while 'A' & 'B' low set safety valves fail open. All four SG's will be faulted.
While in E-0, Reactor Trip or Safety Injection, the crew will have to identify and mitigate two separate failures while dealing with complications of only having the 'B' train emergency bus available:
Event 6: No Aux Feed pumps will auto start. The 'A' MDAFW pump is not available due to the prior loss of bus 34C and the 'B' MDAFW pump will trip on over current once manually started. Steam supply valves must be opened to start the Turbine Driven AFW pump. [Critical Task B.4] - Establish at least 530 gpm AFW flow to the SGs before transition out of E-0.
Event 7: 3SIH*MV8801 B, Charging to Cold Leg Injection Valve, fails to open after the SI signal coincident with P-19 (1900 psia). The parallel valve, 3SIH*MV8801A, will be closed based on the earlier 34C bus failure. The crew will need to identify this and open 3SIH*MV8801 B to provide Charging flow to the core.
[Critical Task B.6] - Manually open valves to establish injection flow from at least one Charging/SI pump before transition out of E-0.
The crew will transition to ECA-2.1, Uncontrolled Depressurization of all Steam Generators. Once the crew establishes aux feed water flow, they will need to limit flow to 100 gpm per faulted SG. [Critical Task B.33]
- Control AFW flow rate to not less than 100 gpm per SG in order to minimize the RCS cooldown rate before a severe (orange-path) challenge develops to the integrity CSF. The crew will have to work through complications of not having the 'A' train emergency bus and ultimately terminate safety injection. During SI termination, the 'A' SG safety valve reseats. The crew must notice this and wait on transition (per prior CAUTION) to E-2 until after SI is terminated. The scenario may end after the crew makes the proper transition to E-2.
- 2. The SRO candidate (US) should classify this event as an ALERT Charlie One based on Unisolable Steam Line Break outside CTMT (BA2).
- 3. Duration of Exam:
90 minutes
Appendix D Scenario Outline Form ES-D-1 Rev 0/1 Facility: Millstone 3 Scenario No.: 2K15 NRC-02 Op-Test No.:
2K15 Examiners:
Operators:
Initial Conditions: IC-18 100% Power Middle of life Turnover:
The QI ant is at 100% 12ower and at middle of life. The "B" HVK Chiller unit is out of service for Qlanned maintenance.
Event Malf.
Event Event No.
No Type*
Description 1
RC07A C (RO)
'A' PZR PORV (3RCS*PCV455A) leak. Results in TIS (US) closing the PORV block valve. (Annunciator response) (Tech Spec entry) 2 R (US)
ISO-NE directed 300 MWe Emergency Load R (RO)
Reduction. (AOP 3575, Rapid Downpower at 5%/min)
Respond to a RPCCW leak (AOP 3561, Loss of TIS (US)
RPCCW). Results in taking the 'B' train of RPCCW out of service. (Tech Spec entry) 4 SI06A M (ALL)
RCS to Inter-System LOCA (outside CTMT).
AOP 3555, Reactor Coolant Leak requires a manual Reactor Trip and Safety Injection.
5 CHL00411 C (RO)
SLCRS 'A' HVR EXH FANISPL Y DMPR CHL00410 (3HVR*FN12A) fails to auto start.
CHL00695 CHL00694 CHL00399 CHL00410 ANL01103 6
Transition to ECA-1.2, LOCA Outside CTMT.
7 LOCA determined to be unisolable. Transition to ECA-1.1, Loss of Emergency Coolant Recirculation.
(N)ormal, (R)eactivity, (l)nstrument, (C)omponent, (M)ajor D-37
SECTION 3 EXAM OVERVIEW
Title:
LOCA Outside Containment Bank scenario, sequence modified.
ID Number:
2K15 NRC-02 Revision:
- 1.
The Scenario will begin with the plant at 100% power and at middle of life. The "B" HVR SLCRS unit is out of service for planned maintenance. This scenario is intended to be used 4 times in the same day, with the BOP position filled by an SRO-I or a surrogate. As such, Instrument/Component malfunctions have been omitted from the BOP side in an effort to reduce run time.
Event 1: A PZR power operated relief valve (PORV), 3RCS*PCV455A, will begin to leak.
The crew will carry out the actions of the Annunciator Response Procedure (or AOP 3555, Reactor Coolant Leak) and block the affected PORV. The US will refer to and enter Technical Specification 3.4.4 Action a.
Event 2: ISO - NE will direct the crew to begin an Emergency Load Reduction decreasing unit electrical output by 300 MWe. The crew will use AOP 3575, Rapid Oownpowerto accomplish this down power at 5%/min.
Event 3: Once the downpower is complete and the plant stable, an unisolable leak in the "B" RPCCW train will result in the crew entering AOP 3561, Loss of Reactor Plant Cooling.
The leak will be small enough such that surge tank make-up fill will be able to keep up with the leak rate. The crew will carry out the leak isolation steps in AOP 3561, and ultimately determine that the leak is unisolable. This will require taking the affected train (B) of RPCCW out of service. The US will refer to and enter Technical Specification 3.7.3 and Technical Requirement 7.4.1 Action A.
Event 4: After the affected train of RPCCW is taken out of service, an Inter-System LOCA will occur. The location of the rupture will be downstream of 3SIH*MV8835 and be unisolable (rupture is in the ESF building, 'A' RHR pump cubicle). The crew should carry out the actions specified in AOP 3555, Reactor Coolant Leak, and determine the leak rate is beyond the capacity of two charging pumps. The crew will be required to initiate a manual Reactor Trip and Safety Injection. The crew will enter E-0, Reactor Trip Or Safety Injection.
Event 5: SLCRS "A" HVR EXH FAN/SPL Y DMPR (3HVR*FN 12A) fails to auto start and must be manually started. [Critical Task] - Manually start at least one train of SLCRS ventilation system (3HVR*FN12A) to minimize radiation release to the public.
Event 6: The crew should proceed through E-0 to step 27 and then transition to ECA-1.2, LOCA Outside CTMT, in an attempt to locate and isolate the leak. The crew will not be successful in isolating the leak by closing 3SIH*MV8835.
Event 7: Once indications of the inability to isolate the leak are obtained, the crew should transition to ECA-1.1, Loss of Emergency Coolant Recirculation, to minimize the amount of safety injection flow to that required for the decay heat load [Critical Task B.29] -
Reduce quench spray and ECCS flow to only 1 train running and establish minimum ECCS flow rate per attachment one prior to reaching 100,000 gallons in RWST. The session will end upon completing the minimization of ECCS injection flow.
- 2.
The SRO candidate (US) should classify this event as a Site Area emergency, based on a loss of both the RCS and CTMT barriers.
- 3.
Duration of Exam:
75 minutes
Appendix D Scenario Outline Form ES-D-1 Rev Oii Facility: Millstone 3 Scenario No.: 2K15 NRC-04 Op-Test No.:
2K15 Examiners:
Operators:
Initial Conditions: 74% Power, Beginning of life, Eguilibrium Xe.
Turnover:
The 12lant is at 74% 12ower. The Turbine Driven Auxiliary Feedwater Pum12 has been out of service for 12 hours1.388889e-4 days <br />0.00333 hours <br />1.984127e-5 weeks <br />4.566e-6 months <br /> for governor maintenance and is ex12ected back in 11 hours1.273148e-4 days <br />0.00306 hours <br />1.818783e-5 weeks <br />4.1855e-6 months <br />.
Event Malf.
Event Event No.
No Type*
Description 1
RX05 4A I (RO)
Narrow Range Loop 4 Thot instrument (RCS-TE441A)
TIS (US) fails high. (AOP 3581 I 3571) (Tech Spec entrv) 2 FW01 R (US)
Condenser vacuum leak requiring load reduction.
R (RO)
(AOP 3575 at 5%/min)
Main Steam header pressure (MSS-PT507) fails low.
Primary channel of Pressurizer Pressure (RCS*PT455)
TIS (US) fails high. (AOP 3581 I 3571) (Tech Spec entrv) 5 RX09A M (ALL)
Pressurizer Pressure (RCS* PT 455) fails low, causing RXR05 2/4 Reactor Trip on OTDT.
RXR34 6
TC03 C (BOP)
Automatic Turbine Trip failed, turbine will not run back.
TC04 Auto MSI failed, both Manual MSI pushbuttons failed, TC06A/B/C/D MSIVs and steam traps must be closed manually.
TC07 A/B/C/D Results in automatic Safety Injection.
RP08AB RPDI0071 RPD10140 7
RP07B C (RO)
Train 'B' of auto SI failed.
8 SW01C/D C (RO)
Running Service Water pumps trip on the reactor trip.
SW02A/B Stand-by Service Water Pumps fail to auto start.
ED11 E ED12E 9
FW20A The 'A' MDAFW pump fails to start in auto or manual.
FW18A The 'B' MDAFW pump discharge valve is shut with a FW21B stem/disc separation. The TDAFW pump is out of FW19 service for governor maintenance.
10 FWO?A Crew enters FR-H.1. MDFW pump will not start; SG FW37 feedwater flow will be established from the condensate pumps.
(N)ormal, (R)eactivity, (I )nstru m ent, (C)omponent, (M)ajor 0-37
EXAM OVERVIEW
Title:
Loss of Heat Sink Modified bank scenario.
ID Number:
2K15 NRC-04 Revision:
- 1. The Session will begin with the plant at 74% power. The Turbine Driven Auxiliary Feedwater Pump has been out of service for 12 hours1.388889e-4 days <br />0.00333 hours <br />1.984127e-5 weeks <br />4.566e-6 months <br /> for governor maintenance and is expected back in 11 hours1.273148e-4 days <br />0.00306 hours <br />1.818783e-5 weeks <br />4.1855e-6 months <br />.
Event 1: Loop 4 That instrument (RCS-TE441 A) will fail high causing rods to step in and Pressurizer Level setpoint to increase by 13%. The RO will perform immediate actions of AOP 3581, Immediate Actions, to confirm a turbine runback is not in progress and place rods in manual. The US will enter AOP 3581, confirm immediate actions are complete and transition to AOP 3571, Instrument Failure Response. The US will direct the RO to take manual control of Charging Flow to stabilize pressurizer level. Next the crew will defeat the failed temperature channel, restore pressurizer level to setpoint, restore TAvE - T REF error to within 1°F, and request l&C to trip bistables. The US will refer to Technical Specification 3.3.1 and log into Action 6 (FU# 7&8). The US will refer to Technical Specification 3.3.2 and log into Action 20 (FU# 5.d) and Action 21 (FU# 9.b).
Event 2: Once actions of AOP 3571 are complete, a leak will occur at condenser vacuum breaker 3ARC-MOV20C. The crew enters AOP 3559, Loss Of Condenser Vacuum, which will direct a rapid load reduction of 5%/min in accordance with AOP 3575, Rapid Oownpower.
Load will be lowered at least 15% before condenser backpressure will stabilize and the crew can stop the load reduction.
Event 3: Main steam header pressure transmitter, 3MSS-PT507, fails high. Turbine driven feedwater pumps will increase speed, steam generator water levels will rise, and steam dump valves will be inoperable in Auto while in the Steam Pressure Mode. The BOP will perform immediate actions of AOP 3581 to take feedwater pump speed control to manual and make corrections before significant transients occur.
The US will enter AOP 3571, Instrument Failure Response and direct the BOP to restore feed pump differential pressure to the normal operating band of 40-175 psid. (Setpoint"" 110 psid @ 50% power.)
Event 4: The controlling channel of pressurizer pressure RCS*PT455 will fail high.
Pressurizer spray valves will open and RCS pressure will lower. The RO will perform immediate actions of AOP 3581, Immediate Actions, to place the master pressure controller in manual and return the output to?: 50% to stabilize pressure. The US will enter AOP 3581, confirm immediate actions are complete and transition to AOP 3571, Instrument Failure Response. The crew will defeat the failed pressure channel and restore pressurizer pressure to setpoint. The crew will be unable to trip bistables, since doing so would cause an automatic reactor trip on 2/4 channels of OT,0.T. The US should recognize that Technical Specification 3.0.3 applies. The US should contact plant management for maintenance assistance and guidance. Other Technical Specifications applicable are 3.3.1 Action 6 (FU# 7, 9 & 10) and 3.3.2 Action 20 (FU# 1.d) and Action 21 (FU# 9.a).
Event 5: The faulted Pressurizer Pressure loop transitions from failed high to failed low; causing a 2/4 Reactor Trip on OTDT.
Event 6: The turbine will not trip. The BOP will attempt to run back the turbine but fail.
Neither MSI pushbutton will function. The BOP must manually close the Main Steam Isolation Valves. Auto MSI is failed, manual isolation of steam line drains is required after safety injection actuation.
Event 7: A Safety Injection is expected to occur from low steamline pressure. Train 'B' of Safety Injection is failed requiring manual Safety Injection.
Event 8: Running Service Water Pumps trip on the reactor trip. Stand-by Service Water Pumps fail to auto start and must be started manually. [Critical Task 8.9] - Manually start one service water pump per train before exiting E-0.
Event 9: The 'A' MDAFW pump fails to start, and the 'B' MDAFW pump discharge valve is shut with a stem/disc separation. As previously stated, the TDAFW pump is out of service for governor maintenance.
Event 10: The crew will proceed through E-0 to step 17 and then transition to FR-H.1. The MDFW pump will not start. The crew will reset Safety Injection and Feedwater Isolation circuits, open the feedwater isolation trip valves and feed at least one steam generator from the condensate pumps. [Critical Task B.43] - Establish condensate flow into at least one SG before RCS bleed and feed is required.
The session will end with condensate flow established.
- 2. The SRO candidate (US) should classify this event as ALERT Charlie One based on RCS Barrier failure, BA 1: Heat Sink Red and required feedwater flow cannot be established within 15 minutes, RCB1.
- 3. Duration of Exam: 90 minutes
ES-401 PWR Examination Outline Form ES-401-2 Facility: Millstone 3 Date of Exam: September 23rd, 2015 RO KJ A Category Points SRO-Only Points Tier Group K
K K
K K
K A A A A G A2 G*
Total 1
2 3
4 5
6 1
2 3
4 Total
- 1.
Emergency &
1 5
2 2
4 3
2 18 1
5 6
Abnormal Plant 2
1 2
2 NIA 2
1 NIA 1
9 1
3 4
Evolutions Tier Totals 6
4 4
6 4
3 27 2
8 10
- 2.
1 2
3 3
2 3
2 1
2 3
5 2
28 3
2 5
Plant Systems 2
1 0
0 2
0 1
1 2
0 0
3 10 1
2 3
Tier 3
3 3
4 3
3 2
4 3
5 5
38 4
4 8
Totals
- 3.
Generic Knowledge and 1
2 3
4 1
2 3
4 Abilities Categories 10 7
4 3
1 2
1 3
1 2
Note:
- 1.
Ensure that at least two topics from every applicable KIA category are sampled within each tier of the RO and SRO-only outlines (i.e., except for one category in Tier 3 of the SRO-only outline, the "Tier Totals" in each Kl A category shall not be less than two). (One Tier 3 Radiation Control KA is allowed if the Kl A is replaced by a Kl A from another Tier 3 Category).
- 2.
The point total for each group and tier in the proposed outline must match that specified in the table. The final point total for each group and tier may deviate by+/- 1 from that specified in the table based on NRC revisions. The final RO exam must total 75 points and the SRO-only exam must total 25 points.
- 3.
Systems/evolutions within each group are identified on the associated outline; systems or evolutions that do not apply at the facility should be deleted and justified; operationally important, site-specific systems/evolutions that are not included on the outline should be added. Refer to Section D of ES-401 for guidance regarding the elimination of inappropriate KIA statements.
- 4.
Select topics from as many systems and evolutions as possible; sample every system or evolution in the group before selecting as second topic for any system or evolution.
- 5.
Absent a plant-specific priority, only those Kl As having an importance rating (IR) of 2.5 or higher shall be selected. Use the RO and SRO ratings for the RO and SRO-only portions, respectively.
- 6.
Select SRO topics for Tiers 1 and 2 from the shaded systems and Kl A categories.
- 7.
- The generic (G) K/As in Tiers I and 2 shall be selected from Section 2 of the KIA Catalog, but the topics must be relevant to the applicable evolution or system. Refer to Section D. I.b ofES-401 for the applicable K/As.
- 8.
On the following pages, enter the Kl A numbers, a brief description of each topic, the topics' importance ratings (IRs) for the applicable license level, and the point totals(#) for each system and category. Enter the group and tier totals for each category in the table above; if fuel handling equipment is sampled in a category other than Category A2 or G* on the SRO-only exam, enter it on the left side of Column A2 for Tier 2, Group 2 (Note #1 does not apply). Use duplicate pages for RO and SRO-only exams.
- 9.
For Tier 3, select topics from Section 2 of the KIA catalog, and enter the KIA numbers, descriptions, IRs, and point totals(#) on Form ES-401-3. Limit SRO selections to K/As that are linked to IOCFR55.43.
G*
Generic KJ As
ES-401 2
Form ES-401-2 ES-40I PWR Examination Outline Form ES-40I-2 Emergency and Abnormal Plant Evolutions - Tier I/Group I (RO)
E/APE #I Name I Safety K
K K
A A
G KIA Topic(s)
IR Function I
2 3
I 2
000007 Reactor Trip -
Operate I monitor Nuclear Instrumentation Stabilization - Recovery I 1 5
on a reactor trip 4.0/4.1 1
0000008 Pressurizer Vapor Interrelations between vapor space break Space Accident I 3 2
and sensors and detectors 2.7/2.7 2
000009 Small Break LOCA Operational implications of the use of steam 13 2
tables on a small break LOCA 3.5/4.2 3
OOOOI l Large Break LOCA Determine or interpret equipment necessary I 3 7
for critical pump water seals during LOCA 3.2/3.4 4
OOOOI5/17 RCP Operational Implications of thermodynamic Malfunctions I 4 4
relationship between RCS loops and SGs 2.9/3.l 5
000022 Loss of Rx Coolant Ability to perform without reference actions Makeup I 2 2.4.49 that require immediate operation 4.6/4.4 6
000025 Loss of RHR Determine or interpret limitations on LPI System/ 4 5
flow and temperature rates of change 3.1/3.5 7
000027 Pressurizer Pressure Knowledge ofEOP entry conditions and Control Malfunction I 3 2.4.1 immediate action steps 4.6/4.8 8
000029 A TWS I 1 15 Operate I monitor AFW system 4.1/3.9 9
000038 Steam Gen. Tube Operate I monitor safety injection and Rupture I 3 30 containment isolation systems on SGTR 4.0/3.8 10 000056 Loss of Off-site Operational implications of the principle of Power I 6 1
cooling by natural convection 3.7/4.2 11 000057 Loss of Vital AC Determine or interpret AC instrument bus Elec. Inst. Bus I 6 6
alarms for the inverter and alternate source 3.2/3.7 12 000062 Loss of Nuclear Operate I monitor control of flow rates to Service Water I 4 6
components cooled by the SWS 2.912.9 13 000065 Loss of Instrument Reasons for: Knowing effects on plant Air I 8 3
operation of isolating equipment from air 2.9/3.4 14 W /E04 LOCA Outside Operational implications of annunciators, Containment I 3 3
indicating signals, and remedial actions 3.5/3.9 15 W /EI I Loss of Emergency Operational implications of components, Coolant Recirc. I 4 1
capacity, & function of emergency systems 3.7/4.0 I6 W/E05 Loss of Secondary Reasons for normal, abnormal and Heat Sink I 4 2
emergency operating procedures 3.7/4.1 I7 000077 Generator Voltage Interrelations between Generator Voltage and Electric Grid I
and Grid Disturbances and motors 3.1/3.2 18 Disturbances I 6 KIA Category Totals:
5 2
2 4
3 2
Group Point Total:
18
ES-401 3
Form ES-401-2 ES-401 PWR Examination Outline Form ES-401-2 Emergency and Abnormal Plant Evolutions - Tier I/Group 2 (RO)
E/APE #I Name I Safety K
K K
A A
G KIA Topic(s)
IR Function 1
2 3
1 2
000003 Dropped Control Reasons for reset of demand position counter Rod I 1 6
to zero 2.7/3.0 19 000032 Loss of Source Operate I monitor manual restoration of Range NI I 7 1
power 3.1/3.4 20 000061 ARM System Operational Implications of detector Alarms I 7 1
limitations 2.512.9 21 000076 High Reactor Reasons for corrective actions as a result of Coolant Activity I 9 5
high RCS fission-product activity level 2.9/3.6 22 Interrelations between SI Termination and W/E02 SI Termination I 3 2
heat removal systems and relation to proper 3.5/3.9 23 operation of the facility W IE 13 Steam Generator Determine or interpret facility conditions Over-pressure I 4 1
and selection of annropriate procedures 2.9/3.4 24 W /E03 Post LOCA Interrelations between control and safety Cooldown Depress. I 4 I
systems, instruments, signals, interlocks, 3.6/4.0 25 failure modes, auto/manual features W/E09 Natural Circ. I 4 Operate I monitor for desired operating 3
results during natural circulation operations 3.5/3.8 26 W /E08 RCS Overcooling -
Ability to recognize abnormal indications for PTS/4 2.4.4 system operating parameters that are entry 4.5/4.7 27 level conditions for EOPs and AOPs KIA Category Point Totals:
1 2
2 2
I I
Group Point Total:
9
ES-401 4
Form ES-401-2 ES-401 PWR Examination Outline Form ES-401-2 Plant Systems - Tier 2/Group I (RO)
System# I Name K
K K
K K
K A
A A
A G
KIA Topic(s)
IR 1
2 3
4 5
6 1
2 3
4 003 Reactor Physical connections I cause-effect Coolant Pump 10 relationship between RCPs and RCS 3.0/3.2 28 003 Reactor Manually operate I monitor seal Coolant Pump 1
injection in the control room 3.3/3.2 29 004 Chemical Manually operate I monitor boron and Volume 1
and control rod reactivity effects in 3.8/3.9 30 Control the control room 005 Residual Effect of a loss of malfunction of Heat Removal 1
RHR on the RCS 3.914.0 31 006 Emergency Effect ofloss or malfunction of Core Cooling 10 valves will have on ECCS 2.6/2.8 32 007 Pressurizer Operational implications of the Relief/Quench 2
method of forming a steam bubble in 3.1/3.4 33 Tank the Pzr 008 Component 2
Knowledge of bus power supplies to Cooling Water the CCW pump, including backup 3.0/3.2 34 008 Component Design features I interlocks for the Cooling Water 9
standby CCW pumps 2.7/2.9 35 010 Pressurizer Operational implications of constant Pressure Control 2
enthalpy expansion through a valve 2.6/3.0 36 012 Reactor Knowledge of bus power supplies to Protection I
RPS channels, components, and 3.3/3.7 37 interconnections 012 Reactor Effect of loss or malfunction of Protection 4
bypass-block circuits on RPS 3.3/3.6 38 013 Engineered 2
Predict impact I mitigate excess Safety Features steam demand 4.3/4.5 39 Actuation 022 Containment Knowledge of abnormal condition Cooling 2.4.11 procedures 4.0/4.2 40 026 Containment Effect of a loss of malfunction of Spray 2
CSS will have on recirc spray system 4.2/4.3 41 039 Main and Monitor automatic operation of Reheat Steam 2
isolation of the MRSS 3.1/3.5 42
ES-401 4
Form ES-401-2 ES-401 PWR Examination Outline Form ES-401-2 Plant Svstems - Tier 2/Group 1 (RO) Continued System# I Name K
K K
K K
K A
A A
A G
KIA Topic(s)
IR 1
2 3
4 5
6 1
2 3
4 059 Main Design features I interlocks which Feedwater 5
control speed of MFW pump turbine 2.5/2.8 43 059 Main Predict I monitor parameters Feedwater 7
associated with operating controls for 2.512.6 44 feed oump speed 061 Auxiliary/
Operational implications of decay Emergency 2
Feedwater heat sources and magnitude 3.213.6 45 062AC Manually operate I monitor all Electrical 1
breakers (including switchyard) in 3.3/3.l 46 Distribution the control room 062AC Predict impact I mitigate improper Electrical 3
sequencing when transferring to or 2.913.4 47 Distribution from an inverter 063 DC Monitor automatic operation of Electrical 1
meters, annunciators, and indicating 2.7/3.1 48 Distribution lights 064 Emergency Monitor automatic operation of:
Diesel Generator 4
number of starts available with an air 3.113.5 49 compressor 073 Process Effect of a loss of malfunction of Radiation 1
PRMS on radioactive effluent 3.614.2 50 Monitoring releases 076 Service Knowledge of bus power supplies to Water 1
service water 2.7/2.7 51 076 Service Manually operate I monitor SWS Water 2
valves in the control room 2.612.6 52 078 Instrument Knowledge of how AOPs are used in Air 2.4.8 coniunction with EOPs 3.8/4.5 53 078 Instrument Physical connections I cause-effect Air 4
relationship between IAS and cooling 2.612.9 54 water to the compressor 103 Containment Manually operate I monitor ESF 3
slave relays in the control room 2.7/2.7 55 Kl A Category Point Totals:
2 3
3 2
3 2
1 2
3 5
2 Group Point Total:
28
ES-401 5
Form ES-401-2 ES-401 PWR Examination Outline Form ES-401-2 Plant Systems - Tier 2/Group 2 (RO)
System# I Name K
K K
K K
K A
A A
A G
KIA Topic(s)
IR 1
2 3
4 5
6 1
2 3
4 016 N on-nucle<!r Parameters and logic used to assess Instrumentation 2.4.21 the status of safety functions, such as 4.014.6 56 core cooling, heat removal, integrity 017 In-Core Effect of loss or malfunction of ITM Temperature 1
sensors and detectors 2.7/3.0 57 Monitor 027 Containment Predict impact I mitigate high Iodine Removal 1
temperature in the filter system 3.0/3.3 58 029 Containment Design features I interlocks which Purge 2
provides for negative pressure in 2.9/3.1 59 containment 035 Steam Physical connections I cause-effect Generator 13 relationship between SGS and 2.7/2.8 60 condensate system 071 Waste Gas Predict impact I mitigate use of waste Disposal 2
gas release monitors, radiation, gas 3.3/3.6 61 flow rate, and totalizer 072 Area Predict I monitor parameters Radiation 1
associated with operating ARM 3.4/3.6 62 Monitoring controls including radiation levels 075 Circulating Design features I interlocks which Water 1
provide for heat sink 2.5/2.8 63 079 Station Air Ability to interpret and execute 2.1.20 procedure steps 4.6/4.6 64 086 Fire Events related to system operation Protection 2.4.30 that must be reported to internal 2.7/4.1 65 organizations, or external agencies KIA Category Point Totals:
1 0
0 2
0 1
1 2
0 0
3 Group Point Total:
10
ES-401 2
Form ES-401-2 ES-401 PWR Examination Outline Form ES-401-2 Emergency and Abnormal Plant Evolutions - Tier I/Group I (SRO)
E/ APE # I Name I Safety K
K K
A A
G KIA Topic(s)
IR Function I
2 3
I 2
000011 Large Break Recognize abnormal indications that are entry level LOCAi 3 2.4.4 conditions that are entry level for EOPs and AOPs 4.7 76 000015/17 RCP Knowledge of operational implications of EOP Malfunctions I 4 2.4.20 warnings, cautions, and notes 4.3 77 000029 ATWS I I I
Determine or interpret reactor nuclear instrumentation 4.7 78 000056 Loss of Off-site Knowledge ofEOP entry conditions and immediate Power I 6 2.4.1 action steps 4.8 79 000057 Loss of Vital AC Knowledge of operational implications of EOP Elec. Inst. Bus I 6 2.4.20 warnings, cautions, and notes 4.3 80 W /E05 Loss of Ability to prioritize and interpret the significance of Secondary Heat Sink I 4 2.4.45 each annunciator or alarm 4.3 81 KIA Category Totals:
I 5
Group Point Total:
6
ES-401 3
Form ES-401-2 ES-401 PWR Examination Outline Form ES-401-2 Emergency and Abnormal Plant Evolutions - Tier I/Group 2 (SRO)
E/APE #I Name I Safety K
K K
A A
G KIA Topic(s)
IR Function 1
2 3
1 2
Ability to interpret reference materials 000061 ARM System Alarms I 7 2.1.25 such as graphs, curves, tables, etc.
4.2 82 000076 High Reactor Coolant Ability to evaluate plant performance Activity I 9 2.1.7 and make operational judgments 4.7 83 Site Priority: AOP 3571 Selection of or adherence to Instrument Failure Response 1
appropriate procedures NA 84 Site Priority: AOP3578 Knowledge of low power/shutdown Inadvertent CIA 2.4.9 implications in accident mitigation 4.2 85 KIA Category Point Totals:
1 3
Group Point Total:
4
ES-401 4
Form ES-401-2 ES-401 PWR Examination Outline Form ES-401-2 Plant S JStems - Tier 2/Group 1 (SRO)
System# I Name K
K K
K K
K A
A A
A G
KIA Topic(s)
IR 1
2 3
4 5
6 1
2 3
4 004 Chemical and Volume Knowledge of specific Control 2.4.18 bases for EOPs 4.0 86 Predict impact and 005 Residual Heat Removal 4
mitigate RHR valve 2.9 87 malfunction 006 Emergency Core Ability to evaluate plant Cooling 2.1.7 performance and make 4.7 88 operational judgments 007 Pressurizer Predict impact and Relief/Quench Tank 2
mitigate abnormal 3.2 89 pressure in the PRT 073 Process Radiation Predict impact and Monitoring I
mitigate erratic or failed 2.9 90 power suooly KIA Category Point Totals:
3 2
Group Point Total:
5
ES-401 5
Form ES-401-2 ES-401 PWR Examination Outline Form ES-401-2 Plant Systems - Tier 2/Group 2 (SRO)
System# I Name K
K K
K K
K A
A A
A G
KIA Topic(s)
IR 1
2 3
4 5
6 1
2 3
4 Predict impact and mitigate rod 001 Control Rod Drive 17 misalignment alarm 3.8 91 016 Non-nuclear Prioritize and interpret the Instrumentation 2.4.45 significance of each 4.3 92 annunciator or alarm Knowledge of the bases in 035 Steam Generator 2.2.25 Technical Specifications for 4.2 93 LCOs and safety limits 1
2 Group Point Total:
3
ES-401 Generic Knowledge and Abilities Outline (Tier 3)
Form ES-401-3 Facility: Millstone Unit 3 Date of Exam: Sept 23, 2015 Category KIA#
Topic RO SRO-Only IR IR 2.1.28 Knowledge of purpose and function of major system components and 4.1 66 4.1 controls
- 1.
2.1.30 Ability to locate and operate components, including local controls 4.4 67 4.0 Conduct of 2.1.32 Ability to explain and apply system limits and precautions 3.8 68 4.0 Operations 2.1.42 Knowledge of new and spent fuel movement procedures 2.5 69 3.4 2.1.45 Ability to identify and interpret diverse indications to validate the response 4.3 94 of another indication Subtotal 4
.;yicr.",.,,
1
- 2.
2.2.2 Ability to manipulate the console controls as required to operate the facility 4.6 70 4.1 between shutdown and designated power levels Equipment 2.2.12 Knowledge of surveillance procedures 3.7 71 4.1 Control 2.2.37 Ability to determine operability and/or availability of safety related 3.6 72 4.6 equipment Knowledge of the process for managing maintenance activates during 2.2.17 power operations, such as risk assessments, work prioritization, and 3.8 95 coordination with the transmission system operator 2.2.20 Knowledge of the process for managing troubleshooting activities 3.8 96 2.2.38 Knowledge of conditions and limits in the facility license 4.5 97 Subtotal 3
}'.;%1,,~~~;
3
- 3.
Ability to use radiation monitoring systems, such as fixed radiation 2.3.5 monitors and alarms, portable survey instruments, personnel monitoring 2.9 73 2.9 equipment, etc.
Radiation Knowledge of radiological safety procedures pertaining to licensed 2.3.13 operator duties, such as rad monitor alarms, Ctmt entry requirements, fuel 3.8 98 handling responsibilities, access to locked high rad areas, etc.
Subtotal 1
,,JM;~~'<
1
- 4.
2.4.13 Knowledge of crew roles and responsibilities during EOP usage 4.0 74 4.6 Emergency 2.4.19 Knowledge ofEOP layout, symbols, and icons 3.4 75 4.1 Procedures/
2.4.1 Knowledge of EOP entry conditions and immediate action steps 4.8 99 Plan 2.4.26 Knowledge of facility protection requirements, including fire brigade and 3.6 100 portable firefighting equipment usage Subtotal 2
2
\\
"cc'>_,-'
Tier 3 Point Total 10 7
ES-401 Record of Rejected K/As Form ES-401-4 Tier I Randomly Reason for Rejection Group Selected Kl A 111 APE.015/017.Kl.1 Oversample of natural circulation, with APE.056.Kl.Oland W/E09.Al.03 112 APE.003.AK3.03 NA MP3. No automatic turbine runback to balance primary and secondary power 112 APE.076.AK2.01 NA MP3. No failed fuel Radiation Monitor. MP3 relies on manual sampling 2/1 003.A4.07 NA MP3. No RCP Seal Bypass path 2/1 004.A4.20 NA MP3. MP3 uses manual valves to align the de-borating demineralizer 2/1 008.K4.07 Oversample of CCW pump power supply, with 008.K2.02 211 010.K5.01 Oversample of steam table use, with EPE.009.Kl.2 2/1 012.Al.01 NA MP3. Operators do not monitor or adjust RPS trip setpoints 211 064.A3.08 NA MP3. No automatic transfer to auto position after manual EDG stop 211 073.K5.01 Oversample of Rad Monitors, with APE.061.Kl.Ol, 073.K3.01, 071.A2.02, 072.Al.01, SRO 073.A2.01 2/1 078.GEN.2.1. l 9 Ability to use PPC to evaluate system status; better tested on operating exam.
Information available for instrument air on the PPC is fairly generic. Candidates will be routinely demonstrating PPC use during the operating exam.
2/1 078.GEN.2.2.37 Determine operability of safety related equipment. Instrument air is not safety related 2/1 078.GEN.2.2.39
< 1 hour1.157407e-5 days <br />2.777778e-4 hours <br />1.653439e-6 weeks <br />3.805e-7 months <br /> Tech Spec LCOs. NA for instrument air 2/1 078.GEN.2.4. l 8 Basis of EOPs. EOPs assume no IAS available. No significant EOP bases step related to Instrument Air.
212 071.A2.07 NA MP3. No actions required with Gaseous Waste System on loss of Met Tower 212 079.GEN.2.2.37 Determine operability of safety related equipment. Station air is not safety related 314 GEN.2.4.28 Security procedures are not an RO job function SRO 111 EPE.O 11.GEN.2.2.39
< 1 hour1.157407e-5 days <br />2.777778e-4 hours <br />1.653439e-6 weeks <br />3.805e-7 months <br /> Tech Spec LCOs is RO level knowledge SRO 112 APE.061.GEN. 2.2.39
< 1 hour1.157407e-5 days <br />2.777778e-4 hours <br />1.653439e-6 weeks <br />3.805e-7 months <br /> Tech Spec LCOs is RO level knowledge SRO 112 Plant Priority Inadvertent CIA Over-sample of Critical Safety Function Status Trees GEN.2.4.21 SRO 2/2 001.A2.2 Effect of loss of power to reactor trip breakers is RO level knowledge SRO 2/2 001.A2.10 Effect of loss of power to Rod Drive MG Sets is RO level knowledge ES-401, Page 27of33
ES-301 Administrative Topics Outline Form ES-301-1 Facility:
Millstone Unit 3 Date of examination:
9/14/15 Examination Level:
RO 0 SRO D Operating Test Number:
2K15 Administrative Topic (see Note)
Type Describe activity to be performed Code*
Perform AC electrical source inoperability Conduct of Operations surveillance requirements.
D,S K/A 2.1.31 (Ability to locate control room switches, controls, and RO A.1.1 indications, and to determine that they correctly reflect the desired plant lineup.)
KIA Rating: 4.6 I 4.3 Determine the required boration time and final control Conduct of Operations M, R rod height for a rapid downpower.
RO A.1.2 K/A 2.1.20 (Ability to interpret and execute procedure steps.)
K/A Rating: 4.6 I 4.6 Equipment Control Recommend a clearance boundary for 3CCl*P1 A.
P, D, R KIA 2.2.13 (Knowledge of tagging and clearance procedures.)
ROA.2 KIA Rating: 4.1 I 4.3 Make preparations required to remove a radiation monitor from service.
Radiation Control D,R K/A 2.3.5 (Ability to use radiation monitoring systems, such as ROA.3 fixed radiation monitors and alarms, portable survey instruments, personnel monitoring equipment, etc.)
KIA Rating: 2.9 I 2.9 Emergency Plan NOTE: All items (five total) are required for SROs. RO applicants require only four items unless they are retaking only the administrative topics (which would require all five items).
- Type Codes & Criteria:
(C)ontrol room, (S)imulator, or Class(R)oom (O)irect from bank ( s3 for ROs; s4 for SROs & RO retakes)
(N)ew or (M)odified from bank ( ;;::-:1)
(P)revious 2 exams ( s1; randomly selected)
ES-301, Page 22 of 27
ES-301 Administrative Topics Outline Form ES-301-1 Facility:
Millstone Unit 3 Date of examination:
9114/15 Examination Level:
Operating Test Number:
2K15 Administrative Topic (see Note)
Type Describe activity to be performed Code*
Loss of containment closure.
Conduct of Operations D,R KIA 2.1.36 (Knowledge of procedures and limitations involved in SRO A1.1 core alterations.)
K/A Rating: 3. 0 I 4.1 Review and approve reactivity calculation.
Conduct of Operations P,M,R KIA 2.1.37 (Knowledge of procedures, guidelines, or limitations SRO A1.2 associated with reactivity management.)
KIA Rating: 4.3 I 4.6 Notifications and reportability associated with a safety limit violation.
Equipment Control D,R KIA 2.2.22 (Knowledge of limiting conditions for operations and SRO A.2 safety limits.)
KIA Rating: 4.0 I 4.7 Review and approve a radioactive liquid waste Radiation Control discharge permit.
M,R SRO A.3 K/A 2.3.6 (Ability to approve release permits.)
KIA Rating: 2.0 / 3.8 Emergency plan classification and protective action recommendation for a general emergency.
Emergency Plan Kl A 2.4.41 (Knowledge of the emergency action level thresholds D, R and classifications.)
SRO A.4 K/A Rating: 2.9 I 4.6 K/A 2.4.44 (Knowledge of emergency plan protective action recommendations.)
K/A Rating: 2.4 I 4.4 NOTE: All items (five total) are required for SROs. RO applicants require only four items unless they are retaking only the administrative topics (which would require all five items).
- Type Codes & Criteria:
(C)ontrol room, (S)imulator, or Class(R)oom (D)irect from bank ( :::;3 for ROs; :::;4 for SROs & RO retakes)
(N)ew or (M)odified from bank ( :::::1)
(P)revious 2 exams ( :::;1; randomly selected)
ES-301, Page 22 of 27
Controi Roomiin-Piant Systems Outiine Form ES-301-2 Rev 0/1 Facility Millstone Unit 3 Date of Examination:
9/14/15 Exam Level:
RO [KJ SRO-I D SRO-U D Operating Test No.:
2K15 Control Room Systems:* 8 for RO; 7 for SRO-I; 2 or 3 for SRO-U System I JPM Title Type Code*
Safety Function
- a.
Perform A Boration At Power D, S 1-004 K/A Number: 004-A4.03; K/A Rating: 2. 7 I 3.2
- b. Vent Unisolated Accumulators K/A Number: 006-A1.13; K/A Rating: 3.5 I 3.7 M, EN,A,E,S 2-006 K/A Number: 006-A4.07; K/A Ratinq: 4.4 I 4.4
- c.
Arm COPPS M, S 3-010 K/A Number: 01 O-K4.03; K/A Rating: 3.8 I 4.1
- d. Aligning RHR For SOR Inventory Control P,D, L, S 4.1-005 K/A Number: 005-A4.01; KIA Rating: 3.6 / 3.4
- e. Natural Circulation Cooldown Using GA-26 P,D,EN,A, E,S 4.2 - 039 K/A Number: 039-A 1.05; K/A Rating: 3.2* I 3.3
- f.
Respond To An Inadvertent Containment Isolation Phase 'A' P, M, EN, A, E, 5-103 K/A Number: 103-A2.03; K/A Rating: 3.5/ 3.8 s
- g. Transferring Bus 340 To Offsite Power M, L,S 6-062 K/A Number: 062-A2.12; K/A Rating: 3.2 I 3.6
- h.
Stop Auxiliary Building Filtration (Lower Levels)
N, S 9-071 K/A Number: APE 060-AA1.02; K/A Rating: 2.9 I 3.1 In-Plant Systems* (3 for RO); (3 for SRO-I); (3 or 2 for SRO-U)
- i.
Local Actions On A Loss Of Instrument Air M,A,E 8-078 K/A Number: APE 065-AA1.04; KIA Rating: 3.5 I 3.4
- j.
Align ESF And Auxiliary Building Sump Pumps, Post LOCA D,A, E, R 6-062 K/A Number: 062-A4.04; K/A Rating: 2.6 I 2.7
- k.
Cross-Connect Service Water To East Switchgear Ventilation D, E, L 4.2 - 076 K/A Number: 076-K1.19; K/A Rating: 3.6 I 3.7 All RO and SRO-I control room (and in-plant) systems must be different and serve different safety functions; all five SRO-U systems must serve different safety functions; in-plant systems and functions may overlap those tested in the control room.
- Type Codes Criteria for RO I SRO-I / SRO-U (A)lternate path 4-6 I 4-6 I 2-3 (C)ontrol room (D)irect from bank s,g I s,8 I -:;;;,4 (E)mergency or abnormal in-plant 21 I 21 I ;:::1 (EN)gineered safety feature
~ I ~ I 21 (control room system)
(L)ow-Power I Shutdown 21 I 21 I ;:::1 (N)ew or (M)odified from bank including 1 (A) 221 22 I ;:::1 (P)revious 2 exams
-:;;;.3 I s,3 I -:;;;.2 (randomly selected)
(R)CA 21 I 21 I ;:::1 (S)imulator ES-301, Page 23 of 27
ES-301 Controi Roomiin-Piant Systems Outiine Form ES-301 *2 Rev 0/1 Facility Millstone Unit 3 Date of Examination:
9/14/15 Exam Level:
ROD SRO-I [KJ SRO-U D Operating Test No.:
2K15 Control Room Systems:* 8 for RO; 7 for SRO-I; 2 or 3 for SRO-U System I JPM Title Type Code*
Safety Function
- a. Perform A Boration At Power D,S 1 - 004 KIA Number: 004-A4.03; KIA Rating: 2.7 13.2
- b. Vent Unisolated Accumulators KIA Number: 006-A 1.13; KIA Rating: 3.513.7 M, EN, A, E, S 2-006 KIA Number: 006-A4.07; KIA Ralina: 4.4 I 4.4
- c.
Arm COPPS M,S 3 - 010 KIA Number: 01 O-K4.03; KIA Rating: 3.8 I 4.1
- d. Aligning RHR For SDR Inventory Control P, D, L, S 4.1-005 KIA Number: 005-A4.01; KIA Rating: 3.613.4
- e.
Natural Circulation Cooldown Using GA-26 P, D, EN,A,E,S 4.2- 039 KIA Number: 039-A 1.05; KIA Rating: 3.2* 13.3
- f.
Respond To An Inadvertent Containment Isolation Phase 'A' P, M, EN, A, E, 5 -103 KIA Number: 103-A2.03; KIA Rating: 3.51 3.8 s
- g.
- h. Stop Auxiliary Building Filtration (Lower Levels)
N,S 9 - 071 I
KIA Number: APE 060-AA 1.02; KIA Rating: 2.9 I 3.1 In-Plant Systems* (3 for RO); (3 for SRO-I); (3 or 2 for SRO-U)
- i.
Local Actions On A Loss Of Instrument Air M,A,E 8- 078 K/A Number: APE 065-AA1.04; K/A Rating: 3.513.4
- j.
Align ESF And Auxiliary Building Sump Pumps, Post LOCA D,A, E,R 6-062 K/A Number: 062-A4.04; KIA Rating: 2.612.7
- k.
Cross-connect Service Water To East Switchgear Ventilation D,E, L 4.2-076 KIA Number: 076-K1.19; KIA Rating: 3.6 I 3. 7 All RO and SRO-I control room (and in-plant) systems must be different and serve different safety functions; all five SRO-U systems must serve different safety functions; in-plant systems and functions may overlap those tested in the control room.
- Type Codes Criteria for RO I SRO-I I SRO-U (A)lternate path 4-6 I 4-6 I 2-3 (C)ontrol room (D)irect from bank s9/ s8/ s4 (E)mergency or abnormal in-plant 21 I 21 I 21 (EN)gineered safety feature
- '! I ~ I 21 (control room system)
(L)ow-Power I Shutdown 21 / 21 I 21 (N)ew or (M)odified from bank including 1 (A) 22 I 22 I 21 (P)revious 2 exams s3 I :<;;;3 I :<;;;2 (randomly selected)
(R)CA 21 / 21 I 21 (S)imulator ES-301, Page 23 of 27
Appendix D Scenario Outline Form ES-D-1 Rev 0/1 Facility: Millstone 3 Scenario No.: 2K15 NRC-01 Op-Test No.: 2K15 Examiners:
Operators:
Initial Conditions: IC-357, 74% Power, Beginning of Life Turnover:
The last shift gerformed a downgower to 74% gower due to intake conditions.
AOP 3569, Severe Weather, has been entered for a hurricane watch. Additionally, last shift 12erformed OP 3301 G to induce gressurizer s12rays. The 'B' Stator Cooling Pum12 is out of service for bearing re12lacement. Orders are to maintain gower stable as management evaluates hurricane tracking.
Event Malf.
Event Event No.
No Type*
Description 1
RX10A I (RO)
Primary Pressurizer Level control channel TIS (US)
(RCS*L T459) fails high causing level to decrease (AOP 3571 ). (Tech Spec entrv) 2 R(RO)
Due to hurricane tracking, Management directs N (BOP) downpower to 60%@ 1% per minute (AOP 3575).
R (US) 3 RX19 I (BOP) 3FWS-PT508 fails high requiring manual control of the Master Speed Controller (AOP 3571 ).
4 ED04C C (RO)
Loss of emergency bus 34C. Isolate letdown TIS (US)
(AOP 3581 ). Recover from loss of 34C (AOP 3577).
(Tech Spec entrv) 5 EG01 M (RO)
A main generator trip occurs, causing a steam line MS02C M (BOP) break outside of containment, upstream of 'C' MSIV.
MS07A M (US)
On the plant trip, the 'C' & 'D' MSIV's fail open and the MS07B
'A' & 'B' low set SG safety valves fail open. All four MS12C SG's are faulted (ECA-2.1 ). Later in event, one SIG MS12D safety reseats (will transition to E-2).
6 FW20C C (BOP)
No Aux Feed Pumps auto start. The Turbine Driven FW18B Aux Feed Pump can be started from MBS.
7 SIR14 C(RO)
Charging injection valve (3SIH*MV8801 B) fails to open below P-19 requiring actions to open.
N)ormal, R)eactivitv, (I )nstrument, ( C)om ponent, (M)ajor D-37
SECTION 3 EXAM OVERVIEW "Title:
Four Faulted SG's New Scenario ID Number:
2K15 NRC-01 Revision:
- 1. The crew takes the shift with the plant at 74% power due to intake conditions. Last shift performed a downpower and entered AOP 3569, Severe Weather, for a hurricane watch. Last shift also performed OP 3301 G section 4.5 "Induce Pressurizer Spray to Equalize Boron Concentration". Additionally, the 'B' Stator Cooling Pump is out of service for a bearing replacement. The crew has direction to maintain power stable as Management evaluates hurricane tracking.
Event 1: The primary pressurizer level control channel (RCS*LT459) will fail high, causing the charging flow control valve to reduce flow, pressurizer level will lower. The RO will place the charging flow control valve in manual and correct charging flow. The US will enter AOP 3571, Instrument Failure Response. The crew will swap control channels and direct l&C to trip bistables. The US will refer to and enter Technical Specification 3.3.1 Action 6 (FU# 11 ). The US will review Technical Specifications 3.3.3.5 and 3.3.3.6 and Technical Requirement 7.4.1 Event 2: Based on hurricane tracking, Station management will direct a downpower to 60% at 1 % per minute. The crew will enter AOP 3575, Rapid Downpower, and perform the downpower.
Event 3: 3FWS-PT508 "Feed Header Pressure Transmitter" will fail high requiring the BOP to take manual control of the feedwater master speed controller. Once the plant is stable the crew will enter and complete actions in AOP 3571, Instrument Failure Response.
Event 4: The 'A' train emergency bus, 34C, will become faulted (&unrecoverable). The RO will perform immediate actions of AOP 3581, Immediate Actions, to simultaneously close the letdown orifice isolation valves and the charging flow control valve. The US will enter AOP 3581, confirm immediate actions are complete, and transition to AOP 3577, Loss of Normal and Offsite Power to a 4kv Emergency Bus, and perform multiple, time critical actions to keep the plant on-line. The following Technical Specifications are in effect; 3.8.1.1 Action a, 3.8.2.1, 3.8.3.1. The following Technical Requirements are in effect: 7.4.1, 7.6.1.
Event 5: After the crew has stabilized the plant, a Main Generator trip will occur causing an automatic Reactor trip. A steam line break will occur outside of containment, upstream of 'C' MSIV. The 'C' & 'D' MSIV's fail open while 'A' & 'B' low set safety valves fail open. All four SG's will be faulted.
While in E-0, Reactor Trip or Safety Injection, the crew will have to identify and mitigate two separate failures while dealing with complications of only having the 'B' train emergency bus available:
Event 6: No Aux Feed pumps will auto start. The 'A' MDAFW pump is not available due to the prior loss of bus 34C and the 'B' MDAFW pump will trip on over current once manually started. Steam supply valves must be opened to start the Turbine Driven AFW pump. [Critical Task B.4] - Establish at least 530 gpm AFW flow to the SGs before transition out of E-0.
Event 7: 3SIH*MV8801 B, Charging to Cold Leg Injection Valve, fails to open after the SI signal coincident with P-19 (1900 psia). The parallel valve, 3SIH*MV8801A, will be closed based on the earlier 34C bus failure. The crew will need to identify this and open 3SIH*MV8801 B to provide Charging flow to the core.
[Critical Task B.6] - Manually open valves to establish injection flow from at least one Charging/SI pump before transition out of E-0.
The crew will transition to ECA-2.1, Uncontrolled Depressurization of all Steam Generators. Once the crew establishes aux feed water flow, they will need to limit flow to 100 gpm per faulted SG. [Critical Task B.33]
- Control AFW flow rate to not less than 100 gpm per SG in order to minimize the RCS cooldown rate before a severe (orange-path) challenge develops to the integrity CSF. The crew will have to work through complications of not having the 'A' train emergency bus and ultimately terminate safety injection. During SI termination, the 'A' SG safety valve reseats. The crew must notice this and wait on transition (per prior CAUTION) to E-2 until after SI is terminated. The scenario may end after the crew makes the proper transition to E-2.
- 2. The SRO candidate (US) should classify this event as an ALERT Charlie One based on Unisolable Steam Line Break outside CTMT (BA2).
- 3. Duration of Exam:
90 minutes
Appendix D Scenario Outline Form ES-D-1 Rev 0/1 Facility: Millstone 3 Scenario No.: 2K15 NRC-02 Op-Test No.:
2K15 Examiners:
Operators:
Initial Conditions: IC-18 100% Power Middle of life Turnover:
The QI ant is at 100% 12ower and at middle of life. The "B" HVK Chiller unit is out of service for Qlanned maintenance.
Event Malf.
Event Event No.
No Type*
Description 1
RC07A C (RO)
'A' PZR PORV (3RCS*PCV455A) leak. Results in TIS (US) closing the PORV block valve. (Annunciator response) (Tech Spec entry) 2 R (US)
ISO-NE directed 300 MWe Emergency Load R (RO)
Reduction. (AOP 3575, Rapid Downpower at 5%/min)
Respond to a RPCCW leak (AOP 3561, Loss of TIS (US)
RPCCW). Results in taking the 'B' train of RPCCW out of service. (Tech Spec entry) 4 SI06A M (ALL)
RCS to Inter-System LOCA (outside CTMT).
AOP 3555, Reactor Coolant Leak requires a manual Reactor Trip and Safety Injection.
5 CHL00411 C (RO)
SLCRS 'A' HVR EXH FANISPL Y DMPR CHL00410 (3HVR*FN12A) fails to auto start.
CHL00695 CHL00694 CHL00399 CHL00410 ANL01103 6
Transition to ECA-1.2, LOCA Outside CTMT.
7 LOCA determined to be unisolable. Transition to ECA-1.1, Loss of Emergency Coolant Recirculation.
(N)ormal, (R)eactivity, (l)nstrument, (C)omponent, (M)ajor D-37
SECTION 3 EXAM OVERVIEW
Title:
LOCA Outside Containment Bank scenario, sequence modified.
ID Number:
2K15 NRC-02 Revision:
- 1.
The Scenario will begin with the plant at 100% power and at middle of life. The "B" HVR SLCRS unit is out of service for planned maintenance. This scenario is intended to be used 4 times in the same day, with the BOP position filled by an SRO-I or a surrogate. As such, Instrument/Component malfunctions have been omitted from the BOP side in an effort to reduce run time.
Event 1: A PZR power operated relief valve (PORV), 3RCS*PCV455A, will begin to leak.
The crew will carry out the actions of the Annunciator Response Procedure (or AOP 3555, Reactor Coolant Leak) and block the affected PORV. The US will refer to and enter Technical Specification 3.4.4 Action a.
Event 2: ISO - NE will direct the crew to begin an Emergency Load Reduction decreasing unit electrical output by 300 MWe. The crew will use AOP 3575, Rapid Oownpowerto accomplish this down power at 5%/min.
Event 3: Once the downpower is complete and the plant stable, an unisolable leak in the "B" RPCCW train will result in the crew entering AOP 3561, Loss of Reactor Plant Cooling.
The leak will be small enough such that surge tank make-up fill will be able to keep up with the leak rate. The crew will carry out the leak isolation steps in AOP 3561, and ultimately determine that the leak is unisolable. This will require taking the affected train (B) of RPCCW out of service. The US will refer to and enter Technical Specification 3.7.3 and Technical Requirement 7.4.1 Action A.
Event 4: After the affected train of RPCCW is taken out of service, an Inter-System LOCA will occur. The location of the rupture will be downstream of 3SIH*MV8835 and be unisolable (rupture is in the ESF building, 'A' RHR pump cubicle). The crew should carry out the actions specified in AOP 3555, Reactor Coolant Leak, and determine the leak rate is beyond the capacity of two charging pumps. The crew will be required to initiate a manual Reactor Trip and Safety Injection. The crew will enter E-0, Reactor Trip Or Safety Injection.
Event 5: SLCRS "A" HVR EXH FAN/SPL Y DMPR (3HVR*FN 12A) fails to auto start and must be manually started. [Critical Task] - Manually start at least one train of SLCRS ventilation system (3HVR*FN12A) to minimize radiation release to the public.
Event 6: The crew should proceed through E-0 to step 27 and then transition to ECA-1.2, LOCA Outside CTMT, in an attempt to locate and isolate the leak. The crew will not be successful in isolating the leak by closing 3SIH*MV8835.
Event 7: Once indications of the inability to isolate the leak are obtained, the crew should transition to ECA-1.1, Loss of Emergency Coolant Recirculation, to minimize the amount of safety injection flow to that required for the decay heat load [Critical Task B.29] -
Reduce quench spray and ECCS flow to only 1 train running and establish minimum ECCS flow rate per attachment one prior to reaching 100,000 gallons in RWST. The session will end upon completing the minimization of ECCS injection flow.
- 2.
The SRO candidate (US) should classify this event as a Site Area emergency, based on a loss of both the RCS and CTMT barriers.
- 3.
Duration of Exam:
75 minutes
Appendix D Scenario Outline Form ES-D-1 Rev Oii Facility: Millstone 3 Scenario No.: 2K15 NRC-04 Op-Test No.:
2K15 Examiners:
Operators:
Initial Conditions: 74% Power, Beginning of life, Eguilibrium Xe.
Turnover:
The 12lant is at 74% 12ower. The Turbine Driven Auxiliary Feedwater Pum12 has been out of service for 12 hours1.388889e-4 days <br />0.00333 hours <br />1.984127e-5 weeks <br />4.566e-6 months <br /> for governor maintenance and is ex12ected back in 11 hours1.273148e-4 days <br />0.00306 hours <br />1.818783e-5 weeks <br />4.1855e-6 months <br />.
Event Malf.
Event Event No.
No Type*
Description 1
RX05 4A I (RO)
Narrow Range Loop 4 Thot instrument (RCS-TE441A)
TIS (US) fails high. (AOP 3581 I 3571) (Tech Spec entrv) 2 FW01 R (US)
Condenser vacuum leak requiring load reduction.
R (RO)
(AOP 3575 at 5%/min)
Main Steam header pressure (MSS-PT507) fails low.
Primary channel of Pressurizer Pressure (RCS*PT455)
TIS (US) fails high. (AOP 3581 I 3571) (Tech Spec entrv) 5 RX09A M (ALL)
Pressurizer Pressure (RCS* PT 455) fails low, causing RXR05 2/4 Reactor Trip on OTDT.
RXR34 6
TC03 C (BOP)
Automatic Turbine Trip failed, turbine will not run back.
TC04 Auto MSI failed, both Manual MSI pushbuttons failed, TC06A/B/C/D MSIVs and steam traps must be closed manually.
TC07 A/B/C/D Results in automatic Safety Injection.
RP08AB RPDI0071 RPD10140 7
RP07B C (RO)
Train 'B' of auto SI failed.
8 SW01C/D C (RO)
Running Service Water pumps trip on the reactor trip.
SW02A/B Stand-by Service Water Pumps fail to auto start.
ED11 E ED12E 9
FW20A The 'A' MDAFW pump fails to start in auto or manual.
FW18A The 'B' MDAFW pump discharge valve is shut with a FW21B stem/disc separation. The TDAFW pump is out of FW19 service for governor maintenance.
10 FWO?A Crew enters FR-H.1. MDFW pump will not start; SG FW37 feedwater flow will be established from the condensate pumps.
(N)ormal, (R)eactivity, (I )nstru m ent, (C)omponent, (M)ajor 0-37
EXAM OVERVIEW
Title:
Loss of Heat Sink Modified bank scenario.
ID Number:
2K15 NRC-04 Revision:
- 1. The Session will begin with the plant at 74% power. The Turbine Driven Auxiliary Feedwater Pump has been out of service for 12 hours1.388889e-4 days <br />0.00333 hours <br />1.984127e-5 weeks <br />4.566e-6 months <br /> for governor maintenance and is expected back in 11 hours1.273148e-4 days <br />0.00306 hours <br />1.818783e-5 weeks <br />4.1855e-6 months <br />.
Event 1: Loop 4 That instrument (RCS-TE441 A) will fail high causing rods to step in and Pressurizer Level setpoint to increase by 13%. The RO will perform immediate actions of AOP 3581, Immediate Actions, to confirm a turbine runback is not in progress and place rods in manual. The US will enter AOP 3581, confirm immediate actions are complete and transition to AOP 3571, Instrument Failure Response. The US will direct the RO to take manual control of Charging Flow to stabilize pressurizer level. Next the crew will defeat the failed temperature channel, restore pressurizer level to setpoint, restore TAvE - T REF error to within 1°F, and request l&C to trip bistables. The US will refer to Technical Specification 3.3.1 and log into Action 6 (FU# 7&8). The US will refer to Technical Specification 3.3.2 and log into Action 20 (FU# 5.d) and Action 21 (FU# 9.b).
Event 2: Once actions of AOP 3571 are complete, a leak will occur at condenser vacuum breaker 3ARC-MOV20C. The crew enters AOP 3559, Loss Of Condenser Vacuum, which will direct a rapid load reduction of 5%/min in accordance with AOP 3575, Rapid Oownpower.
Load will be lowered at least 15% before condenser backpressure will stabilize and the crew can stop the load reduction.
Event 3: Main steam header pressure transmitter, 3MSS-PT507, fails high. Turbine driven feedwater pumps will increase speed, steam generator water levels will rise, and steam dump valves will be inoperable in Auto while in the Steam Pressure Mode. The BOP will perform immediate actions of AOP 3581 to take feedwater pump speed control to manual and make corrections before significant transients occur.
The US will enter AOP 3571, Instrument Failure Response and direct the BOP to restore feed pump differential pressure to the normal operating band of 40-175 psid. (Setpoint"" 110 psid @ 50% power.)
Event 4: The controlling channel of pressurizer pressure RCS*PT455 will fail high.
Pressurizer spray valves will open and RCS pressure will lower. The RO will perform immediate actions of AOP 3581, Immediate Actions, to place the master pressure controller in manual and return the output to?: 50% to stabilize pressure. The US will enter AOP 3581, confirm immediate actions are complete and transition to AOP 3571, Instrument Failure Response. The crew will defeat the failed pressure channel and restore pressurizer pressure to setpoint. The crew will be unable to trip bistables, since doing so would cause an automatic reactor trip on 2/4 channels of OT,0.T. The US should recognize that Technical Specification 3.0.3 applies. The US should contact plant management for maintenance assistance and guidance. Other Technical Specifications applicable are 3.3.1 Action 6 (FU# 7, 9 & 10) and 3.3.2 Action 20 (FU# 1.d) and Action 21 (FU# 9.a).
Event 5: The faulted Pressurizer Pressure loop transitions from failed high to failed low; causing a 2/4 Reactor Trip on OTDT.
Event 6: The turbine will not trip. The BOP will attempt to run back the turbine but fail.
Neither MSI pushbutton will function. The BOP must manually close the Main Steam Isolation Valves. Auto MSI is failed, manual isolation of steam line drains is required after safety injection actuation.
Event 7: A Safety Injection is expected to occur from low steamline pressure. Train 'B' of Safety Injection is failed requiring manual Safety Injection.
Event 8: Running Service Water Pumps trip on the reactor trip. Stand-by Service Water Pumps fail to auto start and must be started manually. [Critical Task 8.9] - Manually start one service water pump per train before exiting E-0.
Event 9: The 'A' MDAFW pump fails to start, and the 'B' MDAFW pump discharge valve is shut with a stem/disc separation. As previously stated, the TDAFW pump is out of service for governor maintenance.
Event 10: The crew will proceed through E-0 to step 17 and then transition to FR-H.1. The MDFW pump will not start. The crew will reset Safety Injection and Feedwater Isolation circuits, open the feedwater isolation trip valves and feed at least one steam generator from the condensate pumps. [Critical Task B.43] - Establish condensate flow into at least one SG before RCS bleed and feed is required.
The session will end with condensate flow established.
- 2. The SRO candidate (US) should classify this event as ALERT Charlie One based on RCS Barrier failure, BA 1: Heat Sink Red and required feedwater flow cannot be established within 15 minutes, RCB1.
- 3. Duration of Exam: 90 minutes