Shine Medical Technologies, Inc. Application for Construction Permit Revision to Sections 13b.3 and 19.4 of the Preliminary Safety Analysis Report
ML15175A131
Person / Time
Site: SHINE Medical Technologies
Issue date: 06/16/2015
From: Bynum R
SHINE Medical Technologies
To:
Document Control Desk, Office of Nuclear Reactor Regulation
References
SMT-2015-031
Download: ML15175A131 (16)


Text

U Mediccl Technologies THIS LETTER CONTAINS PROPRIETARY INFORMATION IN ACCORDANCE WITH 10 CFR 2.390 June 16, 2015 U.S. Nuclear Regulatory Commission ATTN: Document Control Desk Washington, DC 20555 SMT-2015-031 10 CFR 50.30 T6 - 6 o'?

References:

(1) SHINE Medical Technologies, Inc. letter to NRC, dated March 26, 2013, Part One of the SHINE Medical Technologies, Inc. Application for Construction Permit (ML130880226)

(2) SHINE Medical Technologies, Inc. letter to NRC, dated May 31, 2013, Part Two of the SHINE Medical Technologies, Inc. Application for Construction Permit (ML13172A324)

SHINE Medical Technologies, Inc. Application for Construction Permit Revision to Sections 13b.3 and 19.4 of the Preliminary Safety Analysis Report Pursuant to 10 CFR 50.30, SHINE Medical Technologies, Inc. (SHINE) submitted an application for a construction permit to construct a medical isotope facility to be located in Janesville, WI (References 1 and 2). During a review of the Preliminary Safety Analysis Report (PSAR),

SHINE determined that Subsection 13b.3.2 and Subsection 19.4.11.2.13 should be revised to ensure consistency with the SHINE hazardous chemical dispersion analysis. provides an evaluation of the revision to Subsections 13b.3.2 and 19.4.11.2.13 of the PSAR. provides a non-public (proprietary) revision to the SHINE PSAR, incorporating the changes summarized in Enclosure 1. Enclosure 2 is being provided via optical storage media (OSM) as OSM#1. In addition to proprietary information, Enclosure 2 contains security-related information which was identified utilizing the guidance contained in Regulatory Information Summary (RIS) 2005-31. SHINE requests that the NRC withhold Enclosure 2 from public disclosure under 10 CFR 2.390. provides a public (non-proprietary) revision to the SHINE PSAR, incorporating the changes summarized in Enclosure 1. Enclosure 3 is provided via OSM as OSM#2. contains both proprietary and security-related information.

Withhold from public disclosure under 10 CFR 2.390.

Upon removal of Enclosure 2, this letter is uncontrolled.

606 2555 Industrial Drive I Monona, WI 53713 1 P (608) 210-1060 1 F (608) 210-2504 1 www.shinemed.com

Document Control Desk Page 2 THIS LETTER CONTAINS PROPRIETARY INFORMATION IN ACCORDANCE WITH 10 CFR 2.390 provides an affidavit supporting the proprietary treatment of the SHINE proprietary information pursuant to 10 CFR 2.390. Enclosure 2 contains information proprietary to SHINE.

Upon removal of Enclosure 2, this letter is uncontrolled.

If you have any questions, please contact Mr. Jim Costedio, Licensing Manager, at 608/210-1730.

I declare under the penalty of perjury that the foregoing is true and correct.

Executed on June 16, 2015.

Very truly yours, R. Vann Bynum, Ph.D.

Chief Operating Officer SHINE Medical Technologies, Inc.

Docket No. 50-608 Enclosures cc:

Administrator, Region Ill, USNRC Project Manager, USNRC Environmental Project Manager, USNRC Supervisor, Radioactive Materials Program, Wisconsin Division of Public Health (w/o Enclosure 2) contains both proprietary and security-related information.

Withhold from public disclosure under 10 CFR 2.390.

Upon removal of Enclosure 2, this letter is uncontrolled.

ENCLOSURE1 SHINE MEDICAL TECHNOLOGIES, INC.

SHINE MEDICAL TECHNOLOGIES, INC. APPLICATION FOR CONSTRUCTION PERMIT REVISION TO SECTIONS 13B.3 AND 19.4 OF THE PRELIMINARY SAFETY ANALYSIS REPORT EVALUATION OF THE REVISION TO SUBSECTIONS 13B.3.2.3 AND 19.4.11.2.13 OF THE PSAR Subsection 13b.3.2 and Subsection 19.4.11.2.13 of the Preliminary Analysis Report (PSAR) provide descriptions of the hazardous chemical dispersion analysis for the SHINE facility that require change. The differences between the PSAR descriptions of the analysis and the approved analysis performed using Emergency Prediction Information code (EPICode) are summarized below:

PSAR Description (Subsection 13b.3.2 and SHINE Hazardous Chemical Subsection 19.4.11.2.13)

Dispersion Analvsis Atmospheric Stability "Stable" (Stability Class F)

"Neutral" (Stability Class D)

Wind Speed 1 m/s (3.3 ft/s) 4.1 m/s (13.5 ft/s)

Deposition Velocity 1 m/s (3.3 ft/s) 0 m/s (No Deposition)ý1 )

The entire inventory of liquid hazardous The inventory of liquid hazardous Liquid chemicals will evaporate within one hour.

chemicals evaporates from a 100 ft2 Evaporation Time (Subsection 19.4.11.2.13) pool, over a time calculated by EPICode.

(1)

Conservative, since no material is assumed to settle from the plume prior to reaching the receptor.

The meteorological conditions (atmospheric stability and wind speed) assumed in the SHINE hazardous chemical dispersion analysis represent 5 0 th percentile conditions at the SHINE site. Solid powder material release durations were assumed to be one hour in the hazardous chemical dispersion analysis, corresponding to Emergency Response Planning Guideline (ERPG) exposure times.

Additionally, as described in the SHINE Response to RAI 13b.1-1 (Reference 1), accidents and associated controls related to normal chemical hazards, and not to hazardous chemicals associated with, produced from, or affecting the safety of licensed materials, have been removed from Chapter 13 of the PSAR. The revision to the description of the hazardous chemical dispersion analysis provided in Chapter 13, described in the SHINE Response to RAI 13b.1-1, is also applicable to Subsection 19.4.11.2.13 and Table 19.4.11-1 of the PSAR.

While reviewing the PSAR against the hazardous chemical dispersion analysis for the SHINE facility, SHINE also identified the following administrative errors in the PSAR:

The Source Term for Potassium Permanganate is listed as 0.001 lbs in Tables 13b.3-2 and 19.4.11-1 of the PSAR, but was assumed to be 0.066 lbs in the hazardous chemical dispersion analysis. The resulting concentrations previously provided in Tables 13b.3-2 and 19.4.11-1 reflect the 0.066 lbs source term; therefore, the resulting concentrations do not require revision.

Page 1 of 2

" The Worker Concentration for Uranyl Nitrate is listed as 0.024 mg/m 3 in Table 13b.3-2, but was calculated to be 0.13 mg/m 3 in the hazardous chemical dispersion analysis. Though higher, the Worker Concentration was still calculated to be below the PAC-1 value of 0.99 mg/m 3 for Uranyl Nitrate.

The distance to the site boundary was described as 402 m in Subsection 19.4.11.2.13 and Table 19.4.11-1; however, the hazardous chemical dispersion analysis uses a distance of 249 m from the assumed release point to the maximally exposed off-site individual. The resulting concentrations previously provided in Table 19.4.11-1 reflect a distance of 249 m to the site boundary; therefore, the resulting concentrations do not require revision.

The SHINE hazardous chemical dispersion analysis was performed using more realistic conditions than previously described in Subsection 13b.3.2 and Subsection 19.4.11.2.13, and this analysis contains the following conservatisms:

The receptors are assumed to be located at the plume centerline; Releases are assumed to be non-buoyant; No deposition of material is assumed; Evaporation from a 100 ft2 area for liquid releases is conservative, since this value is expected to bound chemical storage areas in the facility; The maximally exposed off-site individual is assumed to be located at the nearest site boundary; The material at risk is taken to be the bounding inventory used with licensed material at the site; The airborne fraction, the product of the airborne release fraction times the respirable fraction, is assumed to be 1.0 for evaporating liquids; The damage ratio, representing the fraction of the inventory impacted, is assumed to be 1.0, meaning that all available material is involved in the event; and A leak path factor (LPF) of 1.0 is assumed for releases, except for nitric acid and dodecane.

For nitric acid and dodecane, an LPF of 0.1 was assumed, corresponding to the most conservative LPF used for the bubble-tight isolation dampers.

SHINE has revised Subsection 13b.3.2 and Subsection 19.4.11.2.13 of the PSAR to address the items described above. A mark-up of the PSAR changes is provided in Attachment 1.

The non-public (proprietary) version of the PSAR, incorporating the changes provided in, is provided in Enclosure 2. The public (non-proprietary) version of the PSAR, incorporating the changes provided in Attachment 1, is provided in Enclosure 3.

The revised Subsection 13b.3.2 and Subsection 19.4.11.2.13, describing the SHINE hazardous chemical dispersion analysis, provide a conservative estimate of the potential consequences to the worker and the public in accordance with Part 1 of the Interim Staff Guidance (ISG) augmenting NUREG-1537 (Reference 2).

References (1)

SHINE Medical Technologies, Inc. letter to NRC, dated December 3, 2014, SHINE Medical Technologies, Inc. Application for Construction Permit, Response to Request for Additional Information (ML14356A527)

(2)

U.S. Nuclear Regulatory Commission, "FINAL Interim Staff Guidance Augmenting NUREG-1 537, Part 1, "Guidelines for Preparing and Reviewing Applications for the Licensing of Non-Power Reactors: Format and Content," for Licensing Radioisotope Production Facilities and Aqueous Homogeneous Reactors," October 17, 2012 (ML12156A069)

Page 2 of 2

ENCLOSURE 1 ATTACHMENT 1 SHINE MEDICAL TECHNOLOGIES, INC.

SHINE MEDICAL TECHNOLOGIES, INC. APPLICATION FOR CONSTRUCTION PERMIT REVISION TO SECTIONS 13B.3 AND 19.4 OF THE PRELIMINARY SAFETY ANALYSIS REPORT EVALUATION OF THE REVISION TO SUBSECTIONS 13B.3.2.3 AND 19.4.11.2.13 OF THE PSAR PRELIMINARY SAFETY ANALYSIS REPORT CHANGES (MARK-UP) 6 pages follow

Chapter 13 - Accident Analysis Analyses of Accidents with Hazardous Chemicals Produced from Licensed Material transported outside of the facility (leakpath factor [LPF]). The five-factor formula is being used to determine the source term of dispersible/respirable material that is released to the environment; namely:

Source term = MAR x DR x ARF x RF x LPF (Equation 13b.3-1)

Source terms are evaluated using models and/or computer codes that conform to NUREG/CR-6410's methodologies. Conservatively, it is assumed that lEs impact the entire inventory in the bounding location; that is, a DR of 1.0 is assumed for postulated accidents.

Releases of liquid toxic chemicals are modeled to limit evaporation since none of the tanks or vessels containing toxic chemicals are pressurized. In all cases, the evaporation of the entire inventory takes several hours.

ARFs/RFs for solid or powder chemicals have been selected to bound those in NUREG/CR-6410, namely an ARF/RF of 1 E-03/1.0 from a spill of powders. Notice that some chemicals are delivered in solid or powder form (e.g., caustic soda) but are prepared or used in liquid form; however, for conservatism, these were modeled as powders, since the source term is higher than when modeled as being released from an evaporating pool. An LPF of 1.0 has been assumed conservatively at this time for all chemicals except for nitric acid and n-dodecane. For nitric acid and n-dodecane, only those inventories associated with licensed materials have been analyzed for release. These inventories exist inside tank vault or hot cells. As such, an LPF of 0.1 has been assumed for these two release scenarios (see Table 13b.3-1). This LPF corresponds to the most conservative LPF used for the bubble-tight isolation dampers.

13b.3.2.3 Chemical Concentrations and Comparison to Acceptable Limits Consequence or chemical dose modeling are evaluated using dispersion models and/or computer codes that conform to NUREG/CR-6410 methodologies.

Typical computer codes to model chemical releases and determine the chemical dose (or concentration) are the ALOHA and EPIcode; as indicated previously both computer codes are widely used for supporting accident analysis and emergency response evaluations. Both codes have been used and accepted by DOE. V&V for both codes has been performed for modeling chemical hazards for the SHINE facility. Because ALOHA only can readily model only about half of these chemicals, the EPIcode was selected to perform chemical dose calculations in this section, and ALOHA was used to benchmark some of the EPIcode runs.

In running EPIcode, no credit is taken for depletion or plateout of chemicals within the facility or during transport to the site boundary or nearest population location. Dispersion calculations performed are done assuming stableneutral meteorological conditions (i.e., eStability Class f;D) and 3413.5 ft/s (4-4.1 m/s) wind speed. These represent 50T! percentile meteorological conditions arc typically seen about 15 percent of the time at the site. Ambient temperature was assumed to be 75 0F (240C). A dep,-,ti-n

.eloc.ity of,.3 Ws', (1 mcs)No deposition of airborne material was assumed, a receptor height of 5 ft. (1.5 m) was used to simulate the height of an individual, and concentrations are plume centerline values. Releases were conservatively modeled as ground non-buoyant.

SHINE Medical Technologies 13b-42 Rev. 42 I

SHINE Medical Technologies 13b-42 Rev. 4-2

Chapter 13 - Accident Analysis Analyses of Accidents with Hazardous Chemicals Produced from Licensed Material Chemical doses or concentrations were determined for the 11 chemicals for a postulated collocated worker within the site boundary (328 ft. [100 m]) at the site boundary and at the nearest residence (817 ft. and 2585 ft. [249 m and 788 m], respectively). Table 13b.3-2, summarizes the results of the source term and concentration calculations for the 11 chemicals.

The acceptance limits were those identified in NUREG/CR-6410 and correspond to Protective Action Criteria (PAC) values corresponding to AEGLs, ERPGs, or TEELs values for such chemicals.

The chemical dose or concentration for the nearest residence is below the PAC 1, 2 and 3 levels (equivalent to ERPG-1, 2 and 3). For the workers postulated to be located within the boundary 328 ft. (100 m) downwind, the concentrations are below the PAC-2 values.

I SHINE Medical Technologies 13b-43 Rev.-1-2

[Proprietary In formation - Withhold from public disclosure under 10 CFR 2.390(a)(4)]

Chapter 13 - Accident Analysis Analyses of Accidents with Hazardous Chemicals Produced from Licensed Material Table 13b.3-2 SHINE Toxic Chemical Source Terms and Concentrations Hazardous ChemicallRelease Mechanism MAR (lb)

Source Term(a)

(Ib)

Worker Concentration (100 m)

MEI Concentration (249 m)

Nearest Residence Concentration (788 m)

ARFIRF PAC-1 PAC-2 PAC-3 Nitric Acid, 12 M, associated with licensed 721 1.0 721 0.53 ppm 24 ppm 92 ppm 0.49 ppm 0.090 ppm 0.012 ppm materials (Evaporating Liquid)

Sulfuric Acid 0.20 8.7mg/rn 160 (Evaprin qid 7,770 1.0 7,770 mg2rn 3 3

mg/r 3

2.4E-06 ppm 4.7E-07 mg/m 3 6.3E-08 mg/m3

-(Evaporating Liquid) mg/m3 3

mg/m3 Calcium Hydroxide 3,182 0.001 3.182 15mg/r 3

240 1,500 0.86 (Dispersed Solid) 3,182 0_001 mg/m3 mg/m3 mg/rn 0.16 mg/rn 0.020 mg/rn Caustic Soda 0.5 50 (Dispersed as both a 1,488 0.001 1.488 0.5 5 mg/rn3 m3 0.40 mg/m 0.073 mg/m 0.010 mg/m powder and liquid)

Img/

3 mg/r 3

[ Proprietary Information ]

4,104 0.001 4.104

[Proprietary

[Proprietary

[ Proprietary 1.1 mg/m 3 0.20 mg/m 3 0.026 mg/m3 (Dispersed Solid)

Information ]

Information ]

Information ]

Ammonium Hydroxide 2300 0.011 ppm 2.OE-03 ppm 2.6E-04 ppm (Evaporating Liquid) 59 ppm

[ Proprietary Information ]

606 0.001 0.606

[Proprietary

[Proprietary

[ Proprietary 0.16 mg/m 3 0.03 mg/m 3 3.9E-03 mg/m3 (Dispersed Solid)

Information]

Information ]

Information g

Dodecane associated 0.0028 0.031 with licensed materials 304 1.0 304 002 0.3 7.9 ppm 0.0023 ppm 4.4E-04 ppm 5.9E-05 ppm (Evaporating Liquid)

Ipp ppm Potassium Permanganate 60:0 8.6 14 78 (Dispersed Solid) 0.066 mg/m 3 mg/m 3 mg/m 3 0.018 mg/r 3 3.3E-03 mg/r 3 4.2E-04 mg/r 3 Tributyl Phosphate 0.6 3.5 125 (Evaporating Liquid) 333 0.001 0.333 mg/m 3 mg/m 3 mg/m 3 0.0082 ppm 1.5E-03 ppm 2.0E-04 ppm Uranyl Nitrate 0.99 5.5 33 0-02-4 (Disrse 480 0.001 0.480 mg/rn3 3

3 0.13 0.024 mg/m 3 3.1E-03 mg/m3

-(Dispersed as a powder) mg/m3 mg/m3 mg/m3

0. 13 mg/m3 I

I a) With the potential for exceeding ERPG-2 limits at site boundary j SHINE Medical Technologies 13b-50 Rev. 42 I

SHINE Medical Technologies 13b-50 Rev. -12

Chapter 19 - Environmental Review Postulated Accidents process equipment that could lead to a radiological release is most likely inside a confined enclosure such as a hot cell, glove box, or tank enclosure. Small spaces such as these provide the confinement of the products of combustion, which can lead to development of a damaging fire environment. Development of damaging fire environment in the general area of the RPF is much less likely due to the large volume of the area. Direct fire damage to important equipment which could lead to a significant radiological release is not likely because redundant control or power circuits are separated by distance to prevent such damage from a single fire, accordingly the DBA is considered to be a fire in an enclosure that may lead to the development of a damaging fire environment.

The design basis fire accident is postulated to occur in an RPF supercell where it contributes to the release of the contents of the Mo extraction feed tank. Fire damage to the tank, associated valves, or process piping could lead to a release of Mo-99 eluate into the supercell enclosure.

Release of this material into the enclosure could lead to an airborne release of radiological material into the cell enclosure and ultimately migration into the RCA ventilation system. The potential release would be mitigated by closure of the bubble-tight dampers in the RCA ventilation system in response to a smoke alarm signal or detection of the radioactive material by the radiation monitoring system. Isolation of the ventilation system would prevent significant release to the environment.

Radiological release of this DBA is bounded by the MHA and contained by the facility and RCA ventilation system. Postulated fire strengths are insufficient to breach the credited facility barrier walls or components. The effects of this DBA and any associated radiological release will be contained by the facility construction and RCA ventilation system components.

19.4.11.2.13 Hazardous Chemical Releases The consequence of chemical releases are evaluated using dispersion models and/or computer codes that conform to NUREG/CR-6410 methodologies.

Typical computer codes to model chemical releases and determine the chemical dose (or concentration) are the ALOHA and EPICode; both computer codes are widely used for supporting accident analysis and emergency response evaluations. Both codes have been used and accepted by government agencies such as DOE. Verification and validation for both codes have been performed for modeling chemical hazards for the SHINE facility. Because ALOHA can readily model only about half of these chemicals, the EPICode was selected to perform chemical dose calculations in this subsection. Both computer codes give comparable results for the hazardous chemicals that they have in common and both codes implement release and dispersion models that are consistent with the guidance in NUREG/CR-6410.

In running _EPICode, no credit is taken for depletion or plate out of chemicals within the facility or during transport to the site boundary or nearest population location. All dispersion calculations performed are done assuming stableneutral meteorological conditions (i.e., Stability Class FDD) and 44.1 m/s wind speed. These represent 50h percentile meteorological conditions are-

typica, see.n ab*ut 15 pc..,nt of the time at the site. Ambient temperature was assumed to be 75 OF, the dp*.itin
  • ..eity is 1 m/.no deposition of airborne material was assumed, and a receptor height of 1.5 m was used to simulate the height of an individual. Concentrations are plume centerline values. Releases were conservatively modeled as ground non-buoyant.

I SHINE Medical Technologies 19.4-101 Rev. 01

Chapter 19 - Environmental Review Postulated Accidents Chapter 19 - Environmental Review Postulated Accidents Chemical dose or concentrations were determined for the 11 chemicals at the site boundary and the nearest residence (402249 and 788m, respectively). Table 19.4.11-1 summarizes the results of the source term and concentration calculations for the 11 chemicals. The material-at-risk (MAR) represents the inventory of hazardous material that is at risk from the postulated scenario.

The MAR for most of the chemicals represents the amount of material in storage. In some cases, the MAR represents the total facility inventory. For other chemicals, the quantity assumed to be released is reduced to account for separate storage locations, or to account for normal industrial chemicals not interacting with licensed materials or affecting the safety of licensed materials. The 11 chemicals were selected for evaluation based on the combination of anticipated bounding facility inventory amounts and high toxicity characteristics (lowest PAC values). The acceptance limits were those identified in NUREG/CR-641 0 and correspond to Protective Action Criteria (PAC) values corresponding to Acute Exposure Guideline Levels (AEGLs), Emergency Response Planning Guideline (ERPG), or Temporary Emergency Exposure Limits (TEEL) values for such chemicals.

The results from the analysis indicate that the chemical dose or concentration for the MQOMEI and the nearest residence is below the PAC-1, PAC-2, and PAC-3 levels (equivalent to ERPG-1 ERPG-2, and ERPG-3). These concentrations are very-conservatively calculated, and are based on the assumption that the entire inventory of liquid hazardous chemicals wil-evaporates withi-eReheurfrom a 100 ft-pool, over a duration calculated by EPICode. In most circ-Umstanccs including nkitri acid,

.~'prto takcz !onger than onc hour thszgifcn Feducving the ptntial.. nc.ntrations do,..n...ind Solid powder material release durations were assumed to be one hour to correspond with ERPG exposure times.

I SHINE Medical Technologies 19.4-102 Rev. G1

[Proprietary Information - Withhold from public disclosure under 10 CFR 2.390(a)(4)]

Chapter 19 - Environmental Review Postulated Accidents Table 19.4.11-1 SHINE Hazardous (Toxic) Chemical Source Terms and Concentrations Hazardous Chemicall Release Mechanism MAR (Ib)

Source Term*

ARF/RF (Ib)

Site Boundary Concentration PAC-1 PAC-2 PAC-3 (403249 m)

Nearest Residence Concentration (788 m)

Nitric Acid, 12M, associated with licensed 6-224 1.0 6

0.53 ppm 24 ppm 92 ppm "00.090 ppm 040.012 ppm materials 721 721 (Evaporating Liquid)

Sulfuric Acid 160 (Evaporating Liquid) 7,770 1.0 7,770 020 mg/r 3 8.7mg/r 3 mg/m 3 4.7E-07 mg/r 3 6.3E-08 mg/r 3 Calcium Hydroxide 3,182 0.001 3.182 15mg/rn 3 240 1,500 0.16 (Dispersed Solid) mg/mi3 mg/m3 mg/rn 0.020 mg/rn Caustic Soda 350 (Dis Sod) 1,488 0.001 1.488 0.5 mg/m3 5 mg/m3 0.073 mg/i 3

0.010 mg/m3 (Dispersed Solid) mg/m3 003m/

[Proprietary Information ]

4,104 0.001 4.104

[Proprietary

[ Proprietary [ Proprietary 0 (Dispersed Solid)

Information ] Information ] Information ]

'.20 mg/r 3 0.026 mg/r 3 Ammonium Hydroxide 59 0.001 0.059 61 ppm 330 ppm 2300 ppm 2.OE-03 ppm 2.6E-04 ppm (Dispersed Solid)

[ Proprietary Information ]

606 0.001 0.606 Proprietary

[ Proprietary [ Proprietary 0 (Dispersed Solid)

Information ] Information ] Information 3.9E-03 mg/r Dodecane associated with 403103 002 A

3&E0 licensed materials 34-1.0 3

PPM2 0.031 ppm 7.9 PPM 4A-E-0 p=.9E-04 (Evaporating Liquid) 304 304 ppm 4E4p p

Potassium Permanganate 66 0.001 (Dispersed Solid) 0.066 8.6 mg/r 3 14 mg/r 3 78 mg/r 3 3.3E-03 mg/r 3 4.2E-04 mg/r 3 Tributyl Phosphate 3.5 125 (Dispersed Solid) 333 0.001 0.333 0.6 mg/r 3 mg/m 3 mg/m 3 1.5E-03 ppm 2.0E-04 ppm Uranyl Nitrate (Dispersed Solid) 480 0.001 0.480 o.99 mg/m3 5.5 mg/m3 33 mg/m3 0.024 mg/m3 3.1E-03 mg/m3 (Likely in solution at SHINE)

II I

SHINE Medical Technologies 19.4-103 Rev. G1

ENCLOSURE 2 CONTAINS PROPRIETARY INFORMATION IN ACCORDANCE WITH 10 CFR 2.390 ENCLOSURE 2 SHINE MEDICAL TECHNOLOGIES, INC.

SHINE MEDICAL TECHNOLOGIES, INC. APPLICATION FOR CONSTRUCTION PERMIT REVISION TO SECTIONS 13B.3 AND 19.4 OF THE PRELIMINARY SAFETY ANALYSIS REPORT PRELIMINARY SAFETY ANALYSIS REPORT NON-PUBLIC VERSION (OSM#1)

/

TM I

Medical Technologies Preliminary Safety Analysis Report Non-Public Version k(OSM#1) contains both proprietary and security-related information.

Withhold from public disclosure under 10 CFR 2.390.

Upon removal of Enclosure 2, this letter is uncontrolled.

ENCLOSURE3 SHINE MEDICAL TECHNOLOGIES, INC.

SHINE MEDICAL TECHNOLOGIES, INC. APPLICATION FOR CONSTRUCTION PERMIT REVISION TO SECTIONS 13B.3 AND 19.4 OF THE PRELIMINARY SAFETY ANALYSIS REPORT PRELIMINARY SAFETY ANALYSIS REPORT PUBLIC VERSION (OSM#2) r TM L

  • Medical Technologies SMT-2015-031 Preliminary Safety Analysis Report

/

Public Version (OSM#2)

(

(

I

ENCLOSURE 4 SHINE MEDICAL TECHNOLOGIES, INC.

SHINE MEDICAL TECHNOLOGIES, INC. APPLICATION FOR CONSTRUCTION PERMIT REVISION TO SECTIONS 13B.3 AND 19.4 OF THE PRELIMINARY SAFETY ANALYSIS REPORT AFFIDAVIT OF RICHARD VANN BYNUM 2 pages follow

Medical Tech-nologies AFFIDAVIT OF RICHARD VANN BYNUM STATE OF WISCONSIN

)ss.

COUNTY OF DANE I, Richard Vann Bynum, Chief Operating Officer of SHINE Medical Technologies, Inc. (SHINE),

do hereby affirm and state:

1.

I am authorized to execute this affidavit on behalf of SHINE. I am authorized to review information submitted to or discussed with the Nuclear Regulatory Commission (NRC) and apply for the withholding of information from public disclosure. The purpose of this affidavit is to provide the information required by 10 CFR 2.390(b) in support of SHINE's request for proprietary treatment of certain confidential commercial and financial information submitted in the SHINE letter SMT-2015-031 with enclosures. SHINE requests that the confidential information contained in Enclosure 2 be withheld from public disclosure in its entirety.

2.

I have knowledge of the criteria used by SHINE in designating information as sensitive, proprietary, or confidential.

3.

Pursuant to the provisions of paragraph (a)(4) of 10 CFR 2.390, the following is furnished for consideration by the NRC in determining whether the information sought to be withheld from public disclosure should be withheld.

a. The information sought to be withheld from public disclosure contained in of SMT-2015-031 is owned by SHINE, its affiliates, or third parties to whom SHINE has an obligation to maintain its confidentiality. This information is and has been held in confidence by SHINE.
b. The information sought to be protected in Enclosure 2 is not available to the public to the best of my knowledge and belief.

1

c. The information contained in Enclosure 2 is of the type that is customarily held in confidence by SHINE, and there is a rational basis for doing so. The information that SHINE is requesting to be withheld from public disclosure includes trade secret, commercial financial information, commercial information, or information that is subject to export controls. SHINE limits access to these elements to those with a "need to know," and subject to maintaining confidentiality.
d. The proprietary information sought to be withheld from public disclosure in includes, but is not limited to: structural configuration, primary and supporting systems of the medical isotope facility, process and system locations, and process details. This would include information regarding the types, quantities, and locations of materials stored on site as would be referenced in facility configuration drawings. Public disclosure of the information in Enclosure 2 would create substantial harm to SHINE because it would reveal trade secrets owned by SHINE, its affiliates, or third parties to whom SHINE has an obligation to maintain its confidentiality.
e. Public disclosure of the information in Enclosure 2 would create substantial harm to SHINE because it would reveal valuable business information regarding SHINE's competitive expectations, assumptions, processes, and current position. Its use by a competitor could substantially improve their competitive position in the design, manufacture, shipment, installation, assurance of quality, or licensing of a similar product.
f. The information contained in Enclosure 2 of SMT-2015-031 is transmitted to the NRC in confidence and under the provisions of 10 CFR 2.390; it is to be received in confidence by the NRC. The information is properly marked.

I declare under the penalty of perjury that the foregoing is true and correct.

Executed on June 16, 2015.

Richard Van Bynum, Ph.D.

COO - SHINE Medical Technologies, Inc.

2