E-mail from Steven Lynch to Jim Costedio Transmitting Draft Request for Additional Information Supporting Shine PSAR
ML15244A506
Person / Time
Site: SHINE Medical Technologies
Issue date: 08/27/2015
From: Steven Lynch
Research and Test Reactors Licensing Branch
To: Jim Costedio
SHINE Medical Technologies
Lynch S, NRR/DPR, 415-1524
Shared Package
ML15244A501 List:
References
TAC MF2305, TAC MF2307
Download: ML15244A506 (1)


Text

From:

Lynch, Steven To:

Jim Costedio (Jim.Costedio@shinemed.com)

Cc:

Gavrilas, Mirela; Adams, Alexander; Kotzalas, Margie; Tripp, Christopher; Adams, Mary

Subject:

Draft Request For Additional Information Supporting SHINE Preliminary Safety Analysis Report Date:

Thursday, August 27, 2015 12:30:00 PM Attachments:

SHINE Draft Benchmark Request for Additional Information.pdf

Jim, By letter dated June 19, 2015 (Agencywide Documents Access and Management System (ADAMS) Accession No. ML15183A290), SHINE Medical Technologies, Inc. (SHINE) responded, in part, to the U.S. Nuclear Regulatory Commission (NRC) staffs March 25, 2015, request for additional information (RAI) (ADAMS Accession No. ML15055A116) to complete the review of SHINEs preliminary safety analysis report supporting a construction permit application.

In the course of reviewing SHINEs RAI responses, the NRC staff has determined that SHINEs response to RAI 6b.3-26 is insufficient and additional information is required to complete the review of SHINEs preliminary safety analysis report in order to prepare a safety evaluation report. Therefore, the NRC has prepared the attached draft RAI in order for SHINE to ensure that the request is clear and understandable. SHINE should contact Steven Lynch with any questions regarding this draft request as soon as possible to arrange a time to discuss the RAI with the appropriate NRC technical staff.

The NRC staff asks that SHINE also review this draft RAI to ensure that proprietary information has not inadvertently been included. Should any proprietary information be identified, contact Steven Lynch within the next ten days. If SHINE does not identify proprietary information within the next ten days, this draft RAI will be made publicly available.

This draft RAI supplements the NRCs previous RAIs related to SHINEs construction permit application dated September 11, 2013, September 19, 2014, January 6, 2015 (ADAMS Accession Nos. ML13231A041, ML14195A159, ML15005A407, respectively),

March 25, 2015, and April 15, 2015 (ADAMS Accession No. ML15099A607).

In order to support the efficient review of SHINEs construction permit application submitted application, SHINE should contact Steven Lynch to discuss an appropriate response time for this request for additional information.

Steve Lynch Project Manager Office of Nuclear Reactor Regulation Division of Policy and Rulemaking, Research and Test Reactors Licensing Office: O-12F08 MS: O-12D20 Phone: 301-415-1524