MONTHYEARNL-14-1349, License Amendment Request to Revise Technical Specifications Regarding Generic Letter 2008-01, Managing Gas Accumulation in Accordance with TSTF-523, Revision 2, Using the Consolidated Line Item Improvement..2015-01-13013 January 2015 License Amendment Request to Revise Technical Specifications Regarding Generic Letter 2008-01, Managing Gas Accumulation in Accordance with TSTF-523, Revision 2, Using the Consolidated Line Item Improvement.. Project stage: Request ML15077A4092015-03-25025 March 2015 Acceptance Review License Amendment Request Project stage: Acceptance Review ML15133A3162015-05-18018 May 2015 Request for Additional Information Project stage: RAI NL-15-0964, Response to Request for Additional Information Regarding SNC License Amendment Request for TSTF-523, Revision 22015-06-16016 June 2015 Response to Request for Additional Information Regarding SNC License Amendment Request for TSTF-523, Revision 2 Project stage: Response to RAI NL-15-2047, Response to Second Request for Additional Information Regarding SNC License Amendment Request for TSTF-523, Revision 22015-11-24024 November 2015 Response to Second Request for Additional Information Regarding SNC License Amendment Request for TSTF-523, Revision 2 Project stage: Request 2015-03-25
[Table View] |
Similar Documents at Hatch |
---|
Category:Letter type:NL
MONTHYEARNL-24-0014, Revised Response to Request for Additional Information Regarding License Amendment Request to Relax the Required Number of Fully Tensioned Reactor Pressure Vessel Head Closure Studs in Technical.2024-01-30030 January 2024 Revised Response to Request for Additional Information Regarding License Amendment Request to Relax the Required Number of Fully Tensioned Reactor Pressure Vessel Head Closure Studs in Technical. NL-23-0889, Units 1 and 2 - License Amendment Request to Revise Technical Specifications to Adopt Risk Informed Completion Times for Residual Heat Removal Service Water (RHRSW) and Plant Service Water (Psw) Systems2023-12-0606 December 2023 Units 1 and 2 - License Amendment Request to Revise Technical Specifications to Adopt Risk Informed Completion Times for Residual Heat Removal Service Water (RHRSW) and Plant Service Water (Psw) Systems NL-23-0879, Request for Exemption from Security Event Notification Implementation2023-11-29029 November 2023 Request for Exemption from Security Event Notification Implementation NL-23-0841, Update to Notice of Intent to Pursue Subsequent License Renewal2023-11-20020 November 2023 Update to Notice of Intent to Pursue Subsequent License Renewal NL-23-0658, Southern Nuclear Operating Company - Response to Request for Additional Information Regarding Quality Assurance Topical Report Submittal2023-08-11011 August 2023 Southern Nuclear Operating Company - Response to Request for Additional Information Regarding Quality Assurance Topical Report Submittal NL-23-0542, CFR 50.46 ECCS Evaluation Model Annual Report for 20222023-08-0909 August 2023 CFR 50.46 ECCS Evaluation Model Annual Report for 2022 NL-23-0624, Report of Changes to Emergency Plan and Summary of 50.54(q) Analysis2023-08-0404 August 2023 Report of Changes to Emergency Plan and Summary of 50.54(q) Analysis NL-23-0566, ISFSI and Edwin I. Hatch Nuclear Plant ISFSI - Registration of Spent Fuel Cask Use2023-07-13013 July 2023 ISFSI and Edwin I. Hatch Nuclear Plant ISFSI - Registration of Spent Fuel Cask Use NL-23-0555, Request for Exemption from Physical Barrier Requirement2023-07-0707 July 2023 Request for Exemption from Physical Barrier Requirement NL-23-0444, Quality Assurance Topical Report Submittal2023-06-15015 June 2023 Quality Assurance Topical Report Submittal NL-23-0457, ISFSI, and Edwin I. Hatch Nuclear Plant, ISFSI - Registration of Spent Fuel Cask Use2023-06-12012 June 2023 ISFSI, and Edwin I. Hatch Nuclear Plant, ISFSI - Registration of Spent Fuel Cask Use NL-23-0422, Inservice Inspection Program Owner'S Activity Report for Refueling Outage 2R272023-05-30030 May 2023 Inservice Inspection Program Owner'S Activity Report for Refueling Outage 2R27 NL-23-0383, SNC Response to Regulatory Issue Summary 2023-01:Preparation And.2023-05-19019 May 2023 SNC Response to Regulatory Issue Summary 2023-01:Preparation And. NL-23-0372, Units 1 & 2, Joseph M. Farley Nuclear Plant - Units 1 & 2, Vogtle Electric Generating Plant - Units 1 & 2, Annual Radiological Environmental Operating Reports for 20222023-05-10010 May 2023 Units 1 & 2, Joseph M. Farley Nuclear Plant - Units 1 & 2, Vogtle Electric Generating Plant - Units 1 & 2, Annual Radiological Environmental Operating Reports for 2022 NL-23-0310, Annual Non-Radiological Environmental Operating Reports and Annual Radioactive Effluent Release Reports for 20222023-04-25025 April 2023 Annual Non-Radiological Environmental Operating Reports and Annual Radioactive Effluent Release Reports for 2022 NL-23-0019, GEN-ISI-ALT-2023-01, Request to Use Provision of a Later Edition of the ASME Boiler and Pressure Vessel Code, Section XI2023-04-12012 April 2023 GEN-ISI-ALT-2023-01, Request to Use Provision of a Later Edition of the ASME Boiler and Pressure Vessel Code, Section XI NL-23-0263, Southern Nuclear Company Submittal of Drug and Alcohol Testing Errors Identified 10 CFR 26.719(c) 30-Day Report2023-04-0505 April 2023 Southern Nuclear Company Submittal of Drug and Alcohol Testing Errors Identified 10 CFR 26.719(c) 30-Day Report NL-23-0208, Independent Spent Fuel Storage Installation ISFSI, Decommissioning Funding Plan Triennial Update2023-03-29029 March 2023 Independent Spent Fuel Storage Installation ISFSI, Decommissioning Funding Plan Triennial Update NL-23-0014, Southern Nuclear Operating Co Submittal of Report on Status of Decommissioning Funding2023-03-29029 March 2023 Southern Nuclear Operating Co Submittal of Report on Status of Decommissioning Funding NL-23-0228, Nuclear Property Insurance Coverage as of April 1, 2023 and Licensee Guarantees of Payment of Deferred Premiums (10 CFR 140.21)2023-03-20020 March 2023 Nuclear Property Insurance Coverage as of April 1, 2023 and Licensee Guarantees of Payment of Deferred Premiums (10 CFR 140.21) NL-23-0179, National Pollutant Discharge Elimination System (NPDES) Permit Renewal2023-03-13013 March 2023 National Pollutant Discharge Elimination System (NPDES) Permit Renewal NL-23-0101, Cycle 28 Core Operating Limits Report Version 12023-02-23023 February 2023 Cycle 28 Core Operating Limits Report Version 1 NL-23-0003, Response to Request for Additional Information Regarding License Amendment Request to Relax the Required Number of Fully Tensioned Reactor Pressure Vessel Head Closure Studs in Technical Specification Table 12023-01-20020 January 2023 Response to Request for Additional Information Regarding License Amendment Request to Relax the Required Number of Fully Tensioned Reactor Pressure Vessel Head Closure Studs in Technical Specification Table 1 NL-23-0069, Correction of Technical Specification Omission and Typographical Error2023-01-20020 January 2023 Correction of Technical Specification Omission and Typographical Error NL-22-0316, Emergency License Amendment Request for Technical Specification 3.7.2 Regarding One-Time Extension of Completion Time for Plant Service Water (Psw) Pump Inoperable2022-11-30030 November 2022 Emergency License Amendment Request for Technical Specification 3.7.2 Regarding One-Time Extension of Completion Time for Plant Service Water (Psw) Pump Inoperable NL-22-0850, Supplement to License Amendment Request to Revise the NFPA 805 Fire Protection Program2022-11-18018 November 2022 Supplement to License Amendment Request to Revise the NFPA 805 Fire Protection Program NL-22-0832, Supplement to License Amendment Request to Revise Technical Specifications to Adopt Risk Informed Completion Times TSTF-505, Revision 2, Provide Risk-Informed Extended Completion Times - RITSTF .2022-10-27027 October 2022 Supplement to License Amendment Request to Revise Technical Specifications to Adopt Risk Informed Completion Times TSTF-505, Revision 2, Provide Risk-Informed Extended Completion Times - RITSTF . NL-22-0800, Supplement to Authorized Relief Request HNP-ISI-RR-05-022022-10-27027 October 2022 Supplement to Authorized Relief Request HNP-ISI-RR-05-02 NL-22-0801, Response to Request for Additional Information Regarding: Application to Revise Technical Specifications to Adopt Technical Specifications Task Force (TSTF) Traveler TSTF-208, Revision 0, Extension of .2022-10-14014 October 2022 Response to Request for Additional Information Regarding: Application to Revise Technical Specifications to Adopt Technical Specifications Task Force (TSTF) Traveler TSTF-208, Revision 0, Extension of . NL-22-0757, Units 1 & 2, Supplement to License Amendment Request to Revise Technical Specifications to Adopt Risk Informed Completion Times TSTF-505, Revision 2, Provide Risk-Informed Extended Completion Times - RITSTF Initiative 4b2022-09-30030 September 2022 Units 1 & 2, Supplement to License Amendment Request to Revise Technical Specifications to Adopt Risk Informed Completion Times TSTF-505, Revision 2, Provide Risk-Informed Extended Completion Times - RITSTF Initiative 4b NL-22-0687, Notice of Intent to Pursue Subsequent License Renewal for Hatch Units 1 & 22022-08-31031 August 2022 Notice of Intent to Pursue Subsequent License Renewal for Hatch Units 1 & 2 NL-22-0406, Request to Relax the Required Number of Fully Tensioned Reactor Pressure Vessel Head Closure Studs in Technical Specification Table 1.1-1, Modes2022-08-19019 August 2022 Request to Relax the Required Number of Fully Tensioned Reactor Pressure Vessel Head Closure Studs in Technical Specification Table 1.1-1, Modes NL-22-0650, Units 1 and 2 - Response to Request for Confirmation of Information Regarding License Amendment Request to Revise the NFPA 805 Fire Protection Program2022-08-19019 August 2022 Units 1 and 2 - Response to Request for Confirmation of Information Regarding License Amendment Request to Revise the NFPA 805 Fire Protection Program NL-22-0590, Response to Request for Additional Information Regarding License Amendment Request to Revise Technical Specifications to Adopt Risk Informed Completion Times TSTF-505, Revision 2, Provide Risk-Informed Exten2022-08-18018 August 2022 Response to Request for Additional Information Regarding License Amendment Request to Revise Technical Specifications to Adopt Risk Informed Completion Times TSTF-505, Revision 2, Provide Risk-Informed Exten NL-22-0672, Registration of Spent Fuel Cask Use2022-08-17017 August 2022 Registration of Spent Fuel Cask Use NL-22-0564, and Vogtle Electric Generating Plant, Registration of Spent Fuel Cask Use2022-07-21021 July 2022 and Vogtle Electric Generating Plant, Registration of Spent Fuel Cask Use NL-22-0510, Plants Units 1 and 2, 10 CFR 50.46 ECCS Evaluation Model Annual Report for 20212022-07-14014 July 2022 Plants Units 1 and 2, 10 CFR 50.46 ECCS Evaluation Model Annual Report for 2021 NL-22-0499, Registration of Spent Fuel Cask Use2022-06-27027 June 2022 Registration of Spent Fuel Cask Use NL-22-0362, Southern Nuclear Operating Company, Inc. - Foreign Ownership, Control, or Influence Five-Year Renewal Filing and NRC Facility Clearance Update2022-06-0101 June 2022 Southern Nuclear Operating Company, Inc. - Foreign Ownership, Control, or Influence Five-Year Renewal Filing and NRC Facility Clearance Update NL-22-0365, Inservice Inspection Program Owner'S Activity Report (OAR-1) for Outage 1R302022-05-31031 May 2022 Inservice Inspection Program Owner'S Activity Report (OAR-1) for Outage 1R30 NL-22-0335, Supplement to Application to Revise Technical Specifications to Adopt Technical Specifications Task Force (TSTF) Traveler TSTF-208, Revision 0, Extension of Time to Reach Mode 2 in LCO 3.0.3 And.2022-05-17017 May 2022 Supplement to Application to Revise Technical Specifications to Adopt Technical Specifications Task Force (TSTF) Traveler TSTF-208, Revision 0, Extension of Time to Reach Mode 2 in LCO 3.0.3 And. NL-22-0344, Annual Radiological Environmental Operating Reports for 20212022-05-10010 May 2022 Annual Radiological Environmental Operating Reports for 2021 NL-22-0315, Technical Specification 5.6.6 Post Accident Monitoring Instrumentation Report for Drywell Temperature Indicator Inoperable for Greater than 30 Days2022-05-0404 May 2022 Technical Specification 5.6.6 Post Accident Monitoring Instrumentation Report for Drywell Temperature Indicator Inoperable for Greater than 30 Days NL-22-0325, Withdrawal of Emergency License Amendment Request for Technical Specification 3.7.2 Regarding One-Time Extension of Completion Time for Plant Service Water (Psw) Pump Inoperable2022-05-0303 May 2022 Withdrawal of Emergency License Amendment Request for Technical Specification 3.7.2 Regarding One-Time Extension of Completion Time for Plant Service Water (Psw) Pump Inoperable NL-22-0283, Supplement to License Amendment Request to Revise Technical Specifications to Adopt Risk Informed Completion Times TSTF-505, Revision 2, Provide Risk-Informed Extended Completion Times - Ritstf.2022-04-29029 April 2022 Supplement to License Amendment Request to Revise Technical Specifications to Adopt Risk Informed Completion Times TSTF-505, Revision 2, Provide Risk-Informed Extended Completion Times - Ritstf. NL-22-0271, Changes to the Physical Security Plan2022-04-19019 April 2022 Changes to the Physical Security Plan NL-22-0240, SNC Response to Regulatory Issue Summary 2022-01: Preparation and Scheduling of Operator Licensing Examinations2022-03-31031 March 2022 SNC Response to Regulatory Issue Summary 2022-01: Preparation and Scheduling of Operator Licensing Examinations NL-21-0918, License Amendment Request to Revise the NFPA 805 Fire Protection Program. with Attachments 3 to 52022-03-31031 March 2022 License Amendment Request to Revise the NFPA 805 Fire Protection Program. with Attachments 3 to 5 NL-22-0220, Units 1 and 2 - Nuclear Property Insurance Coverage as of April 1, 20222022-03-28028 March 2022 Units 1 and 2 - Nuclear Property Insurance Coverage as of April 1, 2022 NL-22-0221, Licensee Guarantees of Payment of Deferred Premiums (10 CFR 140.21)2022-03-28028 March 2022 Licensee Guarantees of Payment of Deferred Premiums (10 CFR 140.21) 2024-01-30
[Table view] |
Text
' Charles R. Pierce Regulatory Affairs Director Southern Nuclear Operating Company, Inc.
40 Inverness Center Parkway Post Office Box 1295 Birmingham, AL 35201 Tel 205.992.7872 Fax 205.992.7601 s JUN 1 6 2015 Docket Nos.: 50-321 NL-15-0964 5.0-366 U. S. Nuclear Regulatory Commission ATIN: Document Control Desk Washington, D. C. 20555-0001 Edwin I. Hatch Nuclear Plant - Units 1 and 2 Request For Additional Information Regarding SNC License Amendment Request for TSTF-523. Revision 2
References:
- 1. SNC Letter NL-14-1349, Edwin I. Hatch Nuclea r Plant- Units 1 and 2 License Amend ment Request to Revise Technical Specifications Regarding Generi c Letter 2008-01, Managing Gas Accumulation in accordance with TSTF-523, Revision 2, Using the Consolidated Line Item Improvement Process (CLIIP), dated January 13, 2015, ML15014A411.
- 2. NRC Letter, Edwin I. Hatch Nuclea r Plant, Units 1 and 2- Request for Additio nal Information (TAG NOS. MF557 9 AND ('AF5580), dated May 18,201 5.
Ladies and Gentlemen:
On January 13, 2015, in accordance with the provisions of 10 CFR 50.90 Southern Nuclear Operating Company (SNC) submitted a request for an amend ment to the technical specifications (TS) for Edwin I. Hatch Nuclear Plant (HNP), Units 1 and 2 (Reference 1).
The proposed amendment would modify TS requirements related to Generi c Letter 2008-01, "Managing Gas Accumulation in Emergency Core Cooling, Decay Heat Removal, and Containment Spray systems," as described in TSTF-523, Revision 2, "Generic Letter 2008-01, Managing Gas Accumulation."
Following the submittal of the HNP License Amend ment Request, SNC received a request for additional information by the NRC on May 18, 2015 (Refere nce 2). The enclosure provides the requested information.
U.S. Nuclear Regulatory Commission
, NL-15-0964 Page2 This letter contains no new NRC commitments. If you have any questio ns, please contact Ken McElroy at (205) 992-7369.
Mr. C. R. Pierce states he is Regulatory Affairs Director of Southern Nuclea r Operat ing Company, is authorized to execute this oath on behalf of Southern Nuclea r Operat ing Compa ny and, to the best of his knowledge and belief, the facts set forth in this letter are true.
Respectfully submitted, t.ft~
C. R. Pierce Regulatory Affairs Director CRP/GLS/Iac Sworn to and subscribed before me this ik_ day of 9.uvJ? ,2015.
Notary Public My commission expires: / 6I/r JZC>t1 I
Enclosure:
Response to Request for Additional Information - TSTF-523 cc: Southern Nuclear Operating Company Mr. S. E. Kuczynski, Chairman, President & CEO Mr. D. G. Bost, Executive Vice President & Chief Nuclear Officer Mr. M. D. Meier, Vice President - Regulatory Affairs Mr. D. R. Vineyard, Vice Presid ent- Hatch Mr. D. R. Madison, Vice Presid ent- Fleet Operations Mr. B. J. Adams, Vice Presid ent- Engineering Mr. G. L. Johnson, Regulatory Affairs Manag er- Hatch RType: CHA02.004 U. S. Nuclear Regulatory Commission Mr. V. M. McCree, Regional Administrator Mr. R. E. Martin, NRR Senior Project Manag er- Hatch Mr. D. H. Hardage, Senior Resident Inspec tor- Hatch State of Georgia Mr. J. H. Turner, Direct or- Environmental Protection Division
Edwin I. Hatch Nuclear Plant - Units 1 and 2 Request For Addition al Informat ion Regarding SNC License Amendment Request for TSTF-523, Revision 2 Enclosure Response to Request for Additional Information - TSTF-523
Enclosure to NL-15-0964 Response to Request for Additional Informa tion- TSTF-523 Page E-1 The NRC staff has reviewed the Edwin I. Hatch, Units 1 and 2 license amend ment request and determined that additional information is necessary as noted below.
RAI1:
An acceptable surveillance must include allowance for gas accumulation until the next surveillance is scheduled. How is this requirement satisfied by the following:
- a. Satisfactorily operati ng a system or subsystem such as a residual heat removal shutdown cooling subsyst em?
- b. Monitoring Reactor Core Isolation Cooling pump suction pressur e?
- c. Use of a procedure designe d to initially ensure that piping is adequately filled and vented?
SNC Response to RA1:
- a. The current systems under GL 2008-01 have been reviewed and the operatin g
procedures for these systems ensure that the system is properly filled and vented after any maintenance activity that could induce gas voids in the system and before being placed in standby or in service to reduce voids upon system operatio n
initiation. Once the system is placed in service, operating parameters are monitored to ensure the capability of the running system is meeting its system requirements and the presence of gas voids is not detected during running. Erratic pump operation, including suction pressure, discharge pressure, and flow oscillations, as well as unusual vibration levels, can be indicative of air or gas accumulation in the system piping. Actions will be taken to document, via Condition Report (CR), and investigate the potential gas intrusion as needed.
If a system is currently running and the 31 day frequency should occur, monitoring the system running parameters, as discussed above, ensures that the system is meeting its system requirements for the required surveillance. If the system is in standby, then the conventional gas accumulation monitoring process will be performed per the required surveillance frequency control program.
- b. As stated above, erratic pump operation, including suction pressure, discharg e
pressure, and flow oscillations, as well as unusual vibration levels, can be indicative of air or gas accumulation in the system piping. During the Reactor Core Isolation Cooling (RCIC) pump operability tests, RCIC pump suction pressure is monitored and recorded. Depending on the reason for the RCIC pump operation, a 0.5% accuracy calibrated Test Pressure Gauge (30" Hg vacuum to 100 psig range) is installed for the test to ensure accuracy. The value is compared to an acceptance range and if outside the acceptance range a CR would be written and the abnormal indication would be investigated. Possible reasons investigated would include the possibility of voids in the RCIC system. Also, per the RCIC system operating procedure, outlet pressure of the RCIC Pump is similarly
Enclosure to NL-15-0964 Response to Request for Additional Informa tion- TSTF-523 Page E-2 recorded and the RCIC pump differential pressure is calculated with an acceptance range verified.
The RCIC gas accumulation program also ensures proper filling and venting and ultrasonic testing of the system suction piping when the RCIC system is placed in standby readiness. Empirical data suggests that the 31 day frequency for monitoring gas voids in the suction piping is adequate, as no voids have been discovered that exceed the allowable value.
- c. As the systems are placed in standby readiness, the operating procedures either include steps to perform actions (e.g. fill and vent) to ensure voids found in the system are removed or provide references to procedures to perform ultrasonic testing to ensure void size is below analyzed limits to ensure the capability of the system is assured. As the systems are manually initiated, vulnerable system piping locations, such as changing suction alignment, may require special actions to ensure the piping is properly filled as part of the operating procedure. If any voids are left in the system, they will be analyzed and verified to be acceptable to ensure they are not degrading the capability of the system.
RAI2:
Please describe the monitoring of other system parameters that could identify a change that could introduce gas into piping between surveillance intervals.
SNC Response to RA2:
Residual Heat Removal (RHR) and Core Spay (CS) systems currently have keep fill systems that have annunciator alarms installed which provide operator information that the respective system water level is low. If this alarm is not clear it may indicate that voids are present and the respective piping system may need to be filled and vented to ensure the system is cleared of gas accumulation. When these Emergency Core Cooling Systems (ECCS) are placed in standby operation readiness, it is verified by steps in the operating procedures that the annunciator alarm is clear.
Also, the operating procedures that perform system valve operability and could potentia lly induce voids during valve cycling, require the appropriate portion of the system piping affected to be filled and vented when that system's valve cycling is complete.
RAI3:
What are representative surveillance frequencies that exist under the Surveillance Frequency Control Program that differ from the TSTF-523 example of 31 days and what is the basis for those changes?
Enclosure to NL-15-0964 Response to Request for Additional Inform ation- TSTF-523 Page E-3 SNC Response to RA3:
When this TSTF-523 Technical Specification change is issued all values for the gas accumulation surveillance requirements (SRs) will be 31 days as per the recommendation in the implementation guidance of this license amendment change. These surveill ance frequencies will then be controlled by the Surveillance Frequency Control Program change process going forward.