|
---|
Category:Annual Report
MONTHYEARML15114A1772015-04-20020 April 2015 Letter Informing the Commission of an Error in the Oregon State University Triga Reactor 2010 Thru 2014 Annual Reports ML14303A3052014-10-23023 October 2014 Submittal of the Oregon State University Radiation Center and Ostr Annual Report for the Period July 1, 2013 Through June 30, 2014 ML11304A0172011-10-26026 October 2011 Oregon State University Triga Reactor (Ostr), Annual Report for Period 07/1/2010-06/30/2011 ML1031301772010-10-26026 October 2010 Oregon State University Triga Reactor (Ostr) - Annual Report for the Period 07/01/2009 Through 06/30/2010 ML0730300572007-10-26026 October 2007 Letter Submitting Oregon State University Radiation Center and Ostr Annual Report for the Period of July 1, 2006 Through June 30, 2007 ML0529205472005-10-17017 October 2005 Oregon State University Triga Reactor Annual Report July 2004-June 2005 ML0430901372004-10-27027 October 2004 Submittal of Oregon State University Radiation Center and Triga Reactor Annual Report for the Period July 1, 2003 Through June 30, 2004 ML0329502422003-10-0808 October 2003 Oregon State University Triga Reactor (Ostr) Annual Report for July 1, 2002 Through June 30, 2003 ML0326710842003-09-11011 September 2003 Correction to the Ostr July 1, 2001 - June 30, 2002 Annual Report ML0231200712002-10-28028 October 2002 Letter Regards Oregon State University Triga Reactor 2015-04-20
[Table view] Category:Letter
MONTHYEARIR 05000243/20232012023-08-24024 August 2023 Oregon State University U.S. Nuclear Regulatory Commission Safety Inspection Report No. 05000243/2023201 ML23143A3132023-07-18018 July 2023 Examination Result Letter No 50-243/OL-23-01, Oregon State University ML23047A5482023-03-0808 March 2023 Examination Confirmation Letter No. 50-243/OL-23-01, Oregon State University ML22199A3092022-07-26026 July 2022 Oregon State University - Issuance of Amendment No. 26 to Renewed Facility Operating License No. R-106 for the Oregon State Triga Reactor ML22102A2842022-04-28028 April 2022 Oregon State University - Review and Approval of the Revised Oregon State Triga Reactor Requalification Plan IR 05000243/20222022022-04-23023 April 2022 Oregon State University - Us Nuclear Regulatory Commission Routine Safety Inspection Report No 05000243-2022202 ML22062B3052022-03-10010 March 2022 Examination Confirmation Letter No. 50-243/OL-22-01, Oregon State University ML22019A2982022-01-19019 January 2022 Oregon State University ,Response to RAI Regarding License Amendment Request, Oregon State University Triga Reactor Dated June 17, 2020 ML21258A0732021-10-22022 October 2021 Oregon State University Request for Additional Information (RAI) Changes ML21299A2502021-10-22022 October 2021 Oregon State University Triga Reactor (Ostr), Docket No. 50-243, License No. R-106 ML21250A3432021-09-20020 September 2021 Oregon State University Closure of Confirmatory Action Letter No. NRR-04-001 on the Site-Specific Compensatory Measures Implementation Plan ML21236A3462021-08-24024 August 2021 Oregon State Univ., License Amendment Request to Revise Requalification Plan for Licensed Operators ML21225A0832021-07-29029 July 2021 Oregon State Univ., Modifications to the OSTR Physical Security Plan (PSP) to Close Out Confirmatory Action Letter No. NRR-04-001 IR 05000243/20212012021-06-0303 June 2021 Oregon State Routine Inspection Report 05000243/2021201 ML21141A2892021-05-21021 May 2021 Oregon State University Triga Reactor (OSTR) - Amendment to Letter Dated June 17, 2020, License Amendment Request to Remove Technical Specification Requirements Related to Instrumented Fuel. ML21119A2362021-04-22022 April 2021 Oregon State University Triga Reactor (Ostr), Follow Up Report of Event Notification 55184 ML21092A1372021-04-0909 April 2021 Oregon State University - Regulatory Audit Re License Amendment Request to Remove Technical Specification Requirements ML20318A3802020-12-18018 December 2020 Oregon State University - Temporary Exemption from the Requirements of 10 CFR Part 50, Appendix E, Section IV.F.2.b Related to Biennial Emergency Exercise (Covid 19) ML20350B7262020-12-10010 December 2020 Extension of Timeframe Required to Complete Biennial Emergency Exercise Per Oregon State Triga Reactor Emergency Response Plan, Facility Operating License No. R-106 ML20338A1302020-11-25025 November 2020 Oregon State University, Change in Level 1 Personnel Update ML20295A4242020-11-16016 November 2020 Notification of Mailing Address Change Regarding Submittal of Fingerprint Cards ML20318A0352020-11-0303 November 2020 Extension of Timeframe Required to Complete Biennial Emergency Exercise Per Oregon State Triga Reactor Emergency Response Plan, Facility Operating License No. R-106 ML20307A4132020-10-22022 October 2020 Oregon State University Triga Reactor (OSTR) ML20247J5482020-09-0303 September 2020 Examination Confirmation Letter No. 50-243/OL-21-001, Oregon State University IR 05000243/20202012020-04-20020 April 2020 Oregon State University - Nuclear Regulatory Commission Routine Inspection Report No. 05000243/2020201 ML19298A4412019-10-21021 October 2019 Oregon State University - Radiation Center and Triga Reactor Annual Report 07/01/2018 - 06/30/2019 ML19290D8132019-10-14014 October 2019 Oregon State University, 10 CFR 50.54(q) Report of Changes to the Ostr Emergency Response Plan Which Do Not Decrease the Effectiveness of the Plan ML19281C3412019-10-0202 October 2019 Oregon State University Triga Reactor (Ostr) 10 CFR 50.54(q) Report of Changes to the Ostr Emergency Response Plan Which Do Not Decrease the Effectiveness of the Plan ML19199A1632019-07-24024 July 2019 Examination Report No. 50-243/OL-19-01, Oregon State University ML19210B8882019-07-22022 July 2019 Oregon State University - Transmittal of Reply to Notice of Violation ML19011A3502019-06-18018 June 2019 Oregon State University Issuance of Amendment Number 25 to Renewed Operating License No. R-106 for the Oregon State Triga Reactor, Technical Specifications ML19098A1672019-04-0303 April 2019 Oregon State University Triga Reactor (Ostr) - Modification of Ostr Physical Security Plan, Docket No. 50-243, License No. R-106 ML19065A0512019-02-28028 February 2019 Oregon State University - Supplement to Letter Dated of January 24, 2019, License Amendment Request to Remove Requirement for Fuel Temperature Measuring and Safety Channels While Transient Operation Modes Are Precluded IR 05000243/20192012019-02-15015 February 2019 Oregon State University - U.S. Nuclear Regulatory Commission Inspection Report No. 50-243/2019-201 ML19052A0512019-01-24024 January 2019 Oregon State Univ. Tiga Reactor (Ostr) - Replacement of November 5, 2018, License Amendment Request to Remove Requirement for Fuel Temperature Measuring and Safety Channels While Transient Operation Modes Are Precluded Letter of ... ML19009A0912019-01-0404 January 2019 Oregon State University - Proposed New Basis for the Limiting Safety System Setting ML18347A2112018-12-0707 December 2018 Oregon State Univ., 10 CFR 50.54(q) Report of Changes to the Ostr Emergency Response Plan Which Do Not Decrease the Effectiveness of the Plan ML18334A1002018-11-26026 November 2018 Oregon State University - Withdrawal of License Amendment Request from October 30, 2018 and Amendment to License Amendment Request from November 5, 2018 ML18312A0612018-11-0505 November 2018 Oregon State University Triga Reactor (Ostr) - License Amendment Request to Remove Requirement for Fuel Temperature Measuring and Safety Channels While Transient Operation Modes Are Precluded ML18312A0602018-10-30030 October 2018 Oregon State University - License Amendment Request to Receive a 20/20 Instrumented Fuel Element ML18297A0512018-10-19019 October 2018 Oregon State University, Request for Removal of Mr. Todd Keller as a Reviewing Official ML18297A1202018-10-19019 October 2018 Oregon State University Triga Reactor (Ostr) - Annual Report for the Period July 1, 2017 Through June 30, 2018 ML18297A0522018-10-19019 October 2018 Oregon State University, Change in Level 1 Personnel Update ML18101A0352018-04-0505 April 2018 Oregon State University - Modification of Physical Security Plan IR 05000243/20172022018-02-20020 February 2018 Oregon State University - Nuclear Regulatory Commission Routine Inspection Report 50-243/2017202 ML17352A4022017-12-13013 December 2017 10 CFR 50.54(q) Report of Changes to the Oregon State University Triga Reactor Emergency Response Plan Which Do Not Decrease the Effectiveness of the Plan ML17353A2292017-12-13013 December 2017 Modification of Oregon State University Triga Reactor Physical Security Plan ML17305A0572017-10-30030 October 2017 Oregon State University - Submittal of Annual Report for the Period July 1, 2016 Through June 30, 2017 ML17193A1612017-07-12012 July 2017 Examination Report No. 50-243/OL-17-01, Oregon State University Nuclear Radiation Center ML17114A2122017-05-0505 May 2017 Oregon State University - Nuclear Regulatory Commission Security-Related Inspection Report No. 50-243/2017-202 2023-08-24
[Table view] |
Text
Radiation Center Oregon State University, 100 Radiation Center, Corvallis, Oregon 97331-5903 T 541-737-2341 I F 541-737-0480 1http://ne.oregonstate.edu/facilities/radiationcenter Oregon State UNIVERSITY April 20, 2015 U.S. Nuclear Regulatory Commission Office of Nuclear Reactor Regulation Division of Policy and Rulemaking ATTN: Michael Balazik Mailstop: OWFN-12D20 Washington, DC 20555-0001
Reference:
Oregon State University TRIGA Reactor (OSTR)
Docket No. 50-243, License No. R-106
Subject:
Annual Report Corrections Mr. Balazik:
The purpose of this letter is to inform the Commission of an error in the OSTR 2010, 2011, 2012, 2013 and 2014 annual reports. Specifically, in each annual report Table V.12 provides information on the annual average measured concentration of radioactivity for environmental samples. In all of these reporting years no radioactivity above the lower limit of detection (LLD) was found for water samples. However, the reported LLDs included 3H when they should not have. This was casued by a clerical error (i.e., pulling the wrong LLD value off the counting reports). The LLD values reported in Table V.12 for the last five years and the corrected (true) values are provided in Table 1 below. Regardless, the counting results for all water samples were all below the corrected (true) LLD for the applicable year. I apologize for any confusion.
Table 1 - LLD of total beta (less 3H) Radioactivity for environmental water samples Value Reported Corrected Value Annual Report Year (VCi ml 1 ) (VCi m[1) 2014 4.97 x 10-6 6.10 x 10-8 2013 5.24 x 10-6 5.25 x 10-8 2012 7.29 x 10-6 5.25 x 10-"
2011 5.42 x 10 6 5.15 x 10s 2010 6.34 x 10-6 5.13 x 10-8 I hereby affirm, state, and daeclre under penalty of perjury that the foregoing is true and correct. Executed on:
Sincerely Director cc: Document Control, USNRC Craig Bassett, USNRC Dr. Ron Adams, OSU Dr. Rich Holdren, OSU Dr. Andy Klein, OSU