IR 05000243/2017202

From kanterella
(Redirected from ML17114A212)
Jump to navigation Jump to search
Oregon State University - Nuclear Regulatory Commission Security-Related Inspection Report No. 50-243/2017-202
ML17114A212
Person / Time
Site: Oregon State University
Issue date: 05/05/2017
From: Anthony Mendiola
Research and Test Reactors Oversight Branch
To: Reese S
Oregon State University
Bassett C, NRR/DPR/PROB, 301-466-4495
Shared Package
ML17114A240 List:
References
IR 2017202
Download: ML17114A212 (4)


Text

May 4, 2017

SUBJECT:

OREGON STATE UNIVERSITY - NUCLEAR REGULATORY COMMISSION SECURITY-RELATED INSPECTION REPORT NO. 50-243/2017-202

Dear Dr. Reese:

From April 10-12, 2017, the U.S. Nuclear Regulatory Commission (NRC or the Commission)

conducted a security inspection at the Oregon State University Radiation Center TRIGA Mark-II reactor facility. The inspection results were discussed on April 12, 2017, with you and other members of your staff, as well as Daniel Harlan, Chairman of the Reactor Operations Committee.

The inspection examined activities conducted under your license as they relate to security and compliance with the Commissions rules and regulations and with the conditions of your license.

The inspector reviewed selected procedures and records, observed activities, and interviewed personnel. Based on the results of this inspection, no findings of non-compliance were identified. No response to this letter is required.

In accordance with Title 10 of the Code of Federal Regulations (10 CFR) Section 2.390, Public inspections, exemptions, requests for withholding, a copy of this letter will be available electronically for public inspection in the NRC Public Document Room or from the NRCs document system (Agencywide Documents Access and Management System (ADAMS)).

ADAMS is accessible from the NRC Web site at http://www.nrc.gov/reading-rm/adams.html (the Public Electronic Reading Room). However, because of the security-related items contained in the enclosure, and in accordance with 10 CFR 2.390(d), a copy of the enclosure will not be available for public inspection. Should you have any questions concerning this inspection, please contact Mr. Craig Bassett at (301) 466-4495 or by electronic mail at Craig.Bassett@nrc.gov.

Sincerely,

/RA/

Anthony J. Mendiola, Chief Research and Test Reactors Oversight Branch Division of Policy and Rulemaking Office of Nuclear Reactor Regulation

Docket No. 50-243 License No. R-106

cc: See next page

Oregon State University Docket No. 50-243

cc:

Mayor of the City of Corvallis Corvallis, OR 97331

Mr. Ken Niles Division Administrator Nuclear Safety Division Oregon Department of Energy 550 Capitol Street N.E., 1st Floor Salem, OR 97301

Dr. Cynthia Sagers Vice President for Research Oregon State University A312 Kerr Administrative Services Bldg.

Corvallis, OR 97331-5904

Dr. Todd Keller Reactor Administrator Oregon State University 100 Radiation Center, A-100 Corvallis, OR 97331-5903

Mr. Daniel Harlan, Chairman Reactor Operations Committee Oregon State University 100 Oak Creek Building Corvallis, OR 97331-5904

Test, Research and Training Reactor Newsletter P.O. Box 118300 University of Florida Gainesville, FL 32611

Pkg.: ML17114A240; Ltr.: ML17114A212; IR: ML17114A227;

  • concurred via email NRC-002 OFFICE NRR/DPR/PROB*

NRR/DPR/PROB/LA*

NRR/DPR/PROB/BC NAME CBassett NParker AMendiola DATE 4/25/17 4/25/17 5/4/17