ML15057A403
| ML15057A403 | |
| Person / Time | |
|---|---|
| Site: | Robinson (DPR-023) |
| Issue date: | 03/26/2015 |
| From: | Martha Barillas Plant Licensing Branch II |
| To: | Glover R Duke Energy Progress |
| Barillas M DORL/LPL2-2 301-415-2760 | |
| References | |
| TAC MF2746 | |
| Download: ML15057A403 (7) | |
Text
UNITED STATES NUCLEAR REGULATORY COMMISSION WASHINGTON, D.C. 20555-0001 Mr. Richard Michael Glover Site Vice President H. B. Robinson Steam Electric Plant Duke Energy 3581 West Entrance Road Hartsville, SC 29550 March 26, 2015
SUBJECT:
H. B. ROBINSON STEAM ELECTRIC PLANT, UNIT NO. 2 - REQUEST FOR ADDITIONAL INFORMATION ON 60-DAY RESPONSE TO LICENSE AMENDMENT REQUEST TO ADOPT NATIONAL FIRE PROTECTION ASSOCIATION STANDARD 805, "PERFORMANCE-BASED STANDARD FOR FIRE PROTECTION FOR LIGHT WATER REACTOR ELECTRIC GENERATING PLANTS" (TAC NO. MF2746)
Dear Mr. Glover:
By letter dated September 16, 2013 (Agencywide Documents Access and Management System (ADAMS) Accession No. ML13267A211), Duke Energy Progress, Inc., the licensee, for H. B. Robinson Steam Electric Plant, Unit No. 2 (Robinson), requested a license amendment to adopt a new fire protection licensing basis that complies with the requirements of Title 10 of the Code of Federal Regulations (10 CFR) Sections 50.48(a) and (c), the guidance in Regulatory Guide 1.205, Revision 1, "Risk-Informed, Performance-Based Fire Protection for Existing Light-Water Nuclear Power Plants, and National Fire Protection Association (NFPA) 805, "Performance-Based Standard for Fire Protection for Light Water Reactor Electric Generating Plants" (2001 edition).
The U.S. Nuclear Regulatory Commission (NRC) staff reviewed the licensee's submittal and determined that additional information was needed in order to complete its review. The NRC staff issued a Request for Additional Information (RAI) dated October 23, 2014 (ADAMS Accession No. ML14289A260). By letter dated November 24, 2014 (ADAMS Accession No. ML14337A098 (non-public)), the licensee provided the 60-day response to the NRC staff's RAI. On March 20, 2015, the licensee resubmitted a letter to supersede the 60-day RAI response requesting to withhold, under 10 CFR 2.390, security-related information contained in the RAI response. The publicly available information contained in the 60-day RAI response letter is available in ADAMS under Accession No. ML15079A025.
Upon review of the 60-day response, the NRC staff determined additional information is needed to complete its review. The enclosed RAI was e-mailed to the licensee in draft form on January 12, 2015 (ADAMS Accession No. ML15056A118), and February 5, 2015 (ADAMS Accession No. ML15056A120). During the RAI clarification calls held on January 26, 2015; February 12, 2015; and March 10, 2015, the licensee agreed to provide the response by March 20, 2015.
On March 16, 2015, an RAI status call was held between the NRC and Duke Energy and the licensee requested a new due date of March 27, 2015, for PRA RAI 05.a.01, 15.01, 18.01, 21.01, 23.d, and 24.01; FM RAI 01.b.01 and 01.c.01; SSA RAI 07.01 and Attachments A, B, and L responses. On March 25, 2015, the licensee requested an extension from March 27, 2015 to April 3, 2015. Additionally, the new due date for PRA RAI 03 and Attachments C, G, J, S, V, and W responses is April 10, 2015. The NRC staff agreed with these dates.
If you have any questions, please contact me at 301-415-2760 or Martha.Barillas@nrc.gov.
Docket No. 50-261
Enclosure:
Request for Additional Information cc w/enclosure: Distribution via Listserv Sincerely, IRA!
Martha Barillas, Project Manager Plant Licensing Branch 11-2 Division of Operating Reactor Licensing Office of Nuclear Reactor Regulation
REQUEST FOR ADDITIONAL INFORMATION LICENSE AMENDMENT REQUEST TO ADOPT NATIONAL FIRE PROTECTION ASSOCIATION STANDARD 805, "PERFORMANCE-BASED STANDARD FOR FIRE PROTECTION FOR LIGHT WATER REACTOR ELECTRIC GENERATING PLANTS,"
DUKE ENERGY PROGRESS, INC.
H. B. ROBINSON STEAM ELECTRIC PLANT, UNIT NO. 2 DOCKET NO. 50-261 Robinson Follow-up Requests for Additional Information (RAls) to First-Round RAI Responses (60-day)
Probabilistic Risk Assessment (PRA) RAI 05.a.01 In a letter dated March 16, 2015 (ADAMS Accession No. ML15079A025), the licensee responded to PRA RAI 05.a and explained that, as part of the integrated analysis provided in response to PRA RAI 3, scenario development of fire propagation from electrical cabinets greater than 440V will be based on draft Frequently Asked Questions (FAQ) No. 14-0009. The U.S. Nuclear Regulatory Commission (NRC) staff has provided comments on the treatment of motor control centers (MCCs) in "NRC Comments on MCC Treatment White Paper August 29, 2014" (ML14245A133) on the draft FAQ No. 14-0009. These NRC staff comments recognize that the basis for the 0.1 multiplier is a 0.19 estimate of the probability of fire breaching a well-sealed cabinet (based on an evaluation of operating experience) and a 0.45 factor of likelihood of damage to targets outside of the cabinet (based on a phenomenological fire modeling evaluation of the geometry of fires within MCC cabinets). There is no provision to change the 0.19 value but the method allows for reevaluation of the 0.45 factor using phenomenological modeling of plant-specific cabinet geometry and ignition sources.
- 1.
Provide the technical justification for any revised values used to represent the probability of damage to targets located outside the MCC cabinet that deviate from accepted values. If the basis for the revised values relies on phenomenological fire modeling that has not been reviewed by the NRC, include a detailed discussion of the modeling that was performed and the results that support the revised values.
- 2.
Describe how these fires will be modeled in the integrated analysis provided in response to PRA RAI 3.
Enclosure PRA RAI 15.01 In a letter dated March 16, 2015 (ADAMS Accession No. ML15079A025), the licensee responded to PRA RAI 15 and explained that inadequate breaker fuse coordination is accounted for in the Fire PRA. The response explains that the "cables causing issues for power supplies" were identified, along with their routing, and used "to create an assumed failures list for breaker coordination." Though it appears that common power supply failures were modeled in the PRA, it is not clear whether possible ignition of affected cables (common enclosure) is considered. The Fire PRA modeling should be consistent with NUREG/CR-6850, "Fire Probabilistic Risk Assessment Methodology for Nuclear Power Facilities," guidance, Section 3.5.4.2, Step 4.2, which states that, "[i]n evaluating the adequacy of cable thermal protection, the criteria for acceptance should be based on a secondary fire concern and not simply exceeding the continuous or overload thermal limit for the cable."
Clarify how the risk associated with secondary fires from cables between uncoordinated breakers is addressed and describe how these fires will be modeled in the integrated analysis provided in response to PRA RAI 3. Alternatively, complete breaker coordination work prior to self-approval, update Attachment S of the LAR as necessary, and discuss how it would be reflected in the Fire PRA for the response to PRA RAI 3.
PRA RAI 18.01 In a letter dated March 16, 2015 (ADAMS Accession No. ML15079A025), the licensee responded to PRA RAI 18 and explained that treatment of self-ignited and cutting-and-welding fires is consistent with FAQ No. 13-0005 for one fire compartment, and for other compartments, these fires were screened out because they were determined to have "insignificant impact." In apparent contrast to this, the response PRA RAI 08 states "cable fires due to cutting and welding are assigned no target sets because a continuous fire watch with an extinguisher is required by procedure to be present during hot work activities and is assumed to extinguish such a fire before it can spread beyond the original tray." The cited responses to PRA RAI 08 and PRA RAI 18 appear to be inconsistent.
Clarify this apparent inconsistency and identify how these cable fires will be modeled in the integrated analysis provided in response to PRA RAI 3.
PRA RAI 21.01 In a letter dated March 16, 2015 (ADAMS Accession No. ML15079A025), the licensee responded to PRA RAI 21 and based on the response, fires that are not believed to cause an automatic trip are assigned a conditional probability of manual trip that reduces the likelihood of the associated fire scenario.
- 1.
Discuss whether your review of the fire-induced initiating events is consistent or conservative compared to the review steps described in NUREG/CR-6850 guidance in Section 2.5.3, "Step 3: Identify Fire-induced Initiating Events Based on Equipment Affected."
- 2.
Discuss any Fire PRA model changes after completing these evaluations that will be included in the integrated analysis provided in response to PRA RAI 3.
PRA RAI 24.01 In a letter dated March 16, 2015 (ADAMS Accession No. ML15079A025), the licensee responded to PRA RAI 24 and in apparent contrast to the response to PRA RAI 24.e, the response to PRA RAI 01.f indicates that there are actions taken in the plant at the remote shutdown locations to recover equipment affected by fire not associated with main control room (MCR) abandonment that are credited in the Fire PRA. Attachment G and the response to PRA RAI 24.e seem to indicate that these actions are designated as defense-in-depth actions.
Actions taken in the plant at the remote shutdown locations to recover equipment affected by fire not associated with MCR abandonment may be recovery actions, since command and control is not established at the remote shutdown panel.
Clarify whether these actions should be considered recovery actions as discussed in Regulatory Guide 1.205, or discuss the rationale for their designation as defense-in-depth. If these actions should be recovery actions, discuss how the additional risk of recovery actions for the applicable scenarios in which the MCR is not abandoned will be modeled in response to PRA RAI 3.
Safe Shutdown Analysis (SSA) RAI 07.01 In a letter dated March 16, 2015 (ADAMS Accession No. ML15079A025), the licensee responded to SSA RAI 07, item 5, and stated that current transformers (CTs) located in switchgear or components that are not credited for safe shutdown (SSD) were excluded from the CTs' open secondary circuit analysis. The purpose of evaluating the potential for causing an open circuit in a CT circuit is to determine the potential for a secondary fire in a different fire area than the originating fire. The concept for a secondary fire due to an open circuited CT applies to any CT circuit, regardless of its use or credit for SSD. Therefore, the licensee's disposition that, "CTs located in switchgear or components that are not credited for SSD were excluded," is not applicable.
Provide a response that addresses the potential fires caused by open circuited CTs, regardless of whether or not the CT has been credited for SSD.
Fire Modeling (FM) RAI 01.b.01 In a letter dated March 16, 2015 (ADAMS Accession No. ML15079A025), the licensee responded to FM RAI 01.b and explained how the effect of the increased heat release rate (HRR), due to fire propagation in cable trays, was accounted for in the hot gas layer (HGL) and multi-compartment analysis (MCA) calculations. In its response, the licensee stated, "Fire spread in each tray is assumed to be offset by the burnout."
Provide technical justification for this assumption, as it is not consistent with the flame spread rates for thermoplastic and thermoset cables recommended in Appendix R of NUREG/CR-6850, Summary and Overview, and Chapter 9 of NUREG/CR-7010, "Cable Heat Release, Ignition, and Spread in Tray Installations During Fire (CHRISTIFIRE)."
In addition, the response does not address the potential effect on the zone of influence (ZOI) from the additional HRR of the cable trays. Explain how the effect of the increased HRR due to fire propagation in the cable trays was accounted for in the ZOI calculations; or provide technical justification for ignoring this effect.
FM RAI 01.c.01 In a letter dated March 16, 2015 (ADAMS Accession No. ML15079A025), the licensee responded to FM RAI 01.c and explained that intervening combustibles within the ignition source ZOI were identified in the walkdowns, and that the HRR contribution from these combustibles were incorporated in the fire modeling analyses. It appears that the ZOI calculations were only performed for 69 kW, 211 kW, 317 kW, and 702 kW fires. This would imply that the licensee may not have accounted for the additional HRR from non-cable intervening combustibles on the ZOI.
Confirm that the effect of the increased HRR from non-cable intervening combustibles was indeed accounted for in the ZOI calculations, or provide technical justification for ignoring this effect.
In addition, the licensee did not provide any details on how the HRR of non-cable intervening combustibles was calculated. Describe the methodology that was used to estimate the HRR from non-cable intervening combustibles in the ZOI, HGL, and MCA calculations.
On March 16, 2015, an RAI status call was held between the NRC and Duke Energy and the licensee requested a new due date of March 27, 2015, for PRA RAI 05.a.01, 15.01, 18.01, 21.01, 23.d, and 24.01; FM RAI 01.b.01 and 01.c.01; SSA RAI 07.01 and Attachments A, B, and L responses. On March 25, 2015, the licensee requested an extension from March 27, 2015 to April 3, 2015. Additionally, the new due date for PRA RAI 03 and Attachments C, G, J, S, V, and W responses is April 10, 2015. The NRC staff agreed with these dates.
If you have any questions, please contact me at 301-415-2760 or Martha.Barillas@nrc.gov.
Docket No. 50-261
Enclosure:
Request for Additional Information Sincerely, IRA/
Martha Barillas, Project Manager Plant Licensing Branch 11-2 Division of Operating Reactor Licensing Office of Nuclear Reactor Regulation cc w/enclosure: Distribution via Listserv DISTRIBUTION:
PUBLIC RidsACRS_MailCTR Resource RidsRgn2MailCenter Resource RidsNrrLABClayton Resource RidsNrrDraAfpb Resource RidsNrrDraApla Resource LFields, NRR BMiller, NRR LPL2-2 R/F RidsNrrDorllp12-2 Resource RidsNrrPMRobinson Resource RidsNrrDorlDpr Resource LRonewicz, NRR JRobinson, NRR AWu, NRR LRonewicz, NRR ADAMS A ccess1on N ML15057A403 o.:
- b
- 1 1y e-ma1 OFFICE LPL2-2/PM LPL2-2/LAiT LPL2-2/LA NRR/DRA/AFPB*
NAME MBarillas LRonewicz BClayton BMiller DATE 3/26/15 3/24/15 3/24/15 2/23/15 OFFICIAL RECORD COPY LPL2-2/BC LPL2-2/PM SHelton MBarillas 3/26/15 3/26/15