Draft Admin RO JPM C NRC RO Admin Job Performance Measure Facility: Vogtle Task No: V-LO-TA-17007 Task
Title:
Perform Quadrant Power Tilt Ratio Surveillance for Inoperable QPTR Monitor Alarm JPM No: V-NRC-JP-14915-HL19 K/A
Reference:
G2.2.12 RO 3.7 SRO 4.1 Examinee: _______________________ NRC Examiner: ____________________
Facility Evaluator: ___________________ Date: _____________________________
Method of testing:
Simulated Performance ______________ Actual Performance __________________
Classroom ______________ Simulator _____________ Plant ______________
Read to the examinee:
I will explain the initial conditions, which steps to simulate or discuss, and provide initiating cues.
When you complete the task successfully, the objective for this job performance measure will be satisfied.
Initial Conditions: Unit 1 is at 100% RTP.
Annunciator ALB10-E06, RADIAL TILT, is lit.
I&C reports that the Quadrant Power Tilt Monitor alarm is inoperable.
Initiating Cue: The Shift Supervisor has directed you to, Perform 14915-1, Special Conditions Surveillance Logs, for QPTR Monitoring, including the completion of Section 7.0, Evaluation and Review, using the following provided data.
1
NI Channel Detector Current 1NI-41 A 409 mA 1NI-42 A 380 mA 1NI-43 A 450 mA 1NI-44 A 415 mA 1NI-41 B 430 mA 1NI-42 B 405 mA 1NI-43 B 445 mA 1NI-44 B 425 mA 2
Task Standard: Candidate performs QPTR calculation correctly using 14915-1, Data Sheet 7, and determines the upper value is 1.03 (> 1.02).
Required Materials: 14915-1, Special Condition Surveillance Logs (rev. 48.1)
Unit 1 Plant Technical Data Book, Tab 5.0 (rev. 159)
Calculator Red Ink Pen, if requested General
References:
None Time Critical Task: No Validation Time: 12 minutes 3
Performance Information Critical steps denoted with an asterisk and bolded.
DATA SHEET 7 Sheet 1 of 2 QUADRANT POWER TILT RATIO NOTES
- The arrangement of the NI rack layout is Channel I, II, IV, and III.
- If ALB 10 D02 or E02 annunciate and power is less than 50% performance of this data sheet is not required.
- If ALB 10 E06 annunciates and power is less than 10% performance of this data sheet is not required.
- Prior to taking readings from the upper and lower detector meters, change scales on the RANGE MILLI-AMPS Switch and then return it to its original position. This will wipe the switch contacts giving a more accurate reading.
- 1. Calculate and record Quadrant Power Tilt Ratio at least once per 12 hours1.388889e-4 days <br />0.00333 hours <br />1.984127e-5 weeks <br />4.566e-6 months <br /> using Sheet 2. PC based spreadsheet may be used for QPTR calculation if normalization factors used are verified current with the PTDB Tab 5.0 revision. If performing a manual calculation, compare PTDB Tab 5.0 with the PC Spreadsheet (if the PC is available) to verify normalization factors.
CUE: If candidate requests TILT DEVIATION from engineering, Perform procedure with the information provided.
Standard: Candidate reviews NOTES and step. PC Spreadsheet is not available.
Comment:
4
- 2. With one Power Range NI inoperable, obtain TILT DEVIATION from Reactor Engineering as determined from moveable incore detectors and verify it is within
+/-0.02 of QPTR obtained from the operable power range NIs. (Use avg. and max. of 3 operable NIs)
CUE: If candidate requests TILT DEVIATION from engineering, Perform procedure with the information provided.
Standard: Candidate reviews step and determines no Power Range NI is inoperable, so obtaining TILT DEVIATION is not required.
Comment:
NOTE A Fluke 8050A Digital Multimeter may be used to obtain more accurate current values for calculation of QPTR.
- 3. If a Fluke 8050A Digital Multimeter will be used to obtain current values from the NI Drawer, record instrument information below:
Instrument ID No._______________________
Cal Due Date__________________________
Standard: Candidate reviews step and determines a Multimeter will not be used.
Comment:
- 4. Verify Quadrant Power Tilt Ratio is less than or equal to 1.02.
Standard: Candidate calculates the Quadrant Power Tilt Ratio using Sheet 2 of Data Sheet 7 and determines the upper value is 1.03 (> 1.02). NOTE: Rounding to three significant digits is not critical.
Comment:
5
- 5. With Quadrant Power Tilt Ratio greater than 1.02, initiate action in accordance with Technical Specification LCO 3.2.4 and continue to calculate and record QPTR once every 12 hours1.388889e-4 days <br />0.00333 hours <br />1.984127e-5 weeks <br />4.566e-6 months <br /> on sheet 2.
Standard: Section 7.0, Evaluation and Review, is correctly completed to notify the Shift Supervisor that the calculated Quadrant Power Tilt Ratio exceeds the Technical Specification limit.
Comment:
Terminating cue: Candidate returns initiating cue sheet.
6
(ANSWER KEY - DO NOT PROVIDE TO CANDIDATES)
DATA SHEET 7 Sheet 2 of 2 DATE ____Today_____
TIME ____Now_______
NI Channel Detector Current Factor*
41 A _409 mA_ x _1.112_ = _454.808_ (1) 42 A _380 mA_ x _1.108_ = _421.040_ (1) 43 A _450 mA_ x _1.025_ = _461.250_ (1) 44 A _415 mA_ x _1.096_ = _454.840_ (1)
Avg = _447.985_ (1)
QPTR (Upper) = Max(upper) = _1.03_(2)
Avg(upper)
NI Channel Detector Current Factor*
41 B _430 mA_ x _1.058_ = _454.940_ (1) 42 B _405 mA_ x _1.071_ = _433.755_ (1) 43 B _445 mA_ x _1.000_ = _445.000_ (1) 44 B _425 mA_ x _1.052_ = _447.100_ (1)
Avg = _445.199_ (1)
QPTR (Lower) = Max(lower) = _1.02_(2)
Avg(lower)
QPTR = Max of QPTR(upper) or QPTR(lower) = _1.03__
TILT DEVIATION = _N/A_
(from Reactor Engineering if applicable)
COMPLETED BY ____Candidate_______
Shift Supervisor Review: ______________/____________/____________
Initial Date Time
- Factor = Normalization Factor from Plant Technical Data Book tab 5.0 Note 1 = Calculations should be performed to 3 decimal places Note 2 = Round to 2 decimal places (if the 3rd decimal is 5 round up, if 3rd decimal is <5, round down) 7
(ANSWER KEY - DO NOT PROVIDE TO CANDIDATES) 7.0 EVALUATION AND REVIEW 7.1 TEST PURPOSE Special Condition(s):
______Quadrant Power Tilt Monitor alarm is inoperable____________
Data Sheet(s) completed (Circle Appropriate Sheets):
1 2 3 4a 4b 5 6 7 8 9 10 11 12 13 14 15 16 17 18 7.2 Results obtained through the performance of this procedure meet the ACCEPTANCE CRITERIA of Section 6.0.
YES NO 7.3 IF no was checked, immediately notify the SS and initiate action in accordance with the actions specified on the data sheet(s) not meeting the acceptance criteria.
7.4 Comments (include any abnormal conditions and corrective actions taken):
___Upper QPTR exceeds 1.02_________________________________
Test Completed and SS Notified: ________________ __________ __________
Supervisory Review: ________________ __________ __________
Signature Date Time 8
Verification of Completion Job Performance Measure No.: V-NRC-JP-14915-HL19 Examinees Name:
Examiners Name:
Date Performed:
Number of Attempts:
Time to Complete:
Question Documentation:
Question: ______________________________________________________________
Response: _____________________________________________________________
Result: Satisfactory / Unsatisfactory Examiners signature and date: ____________________________ ___________
9
Initial Conditions: Unit 1 is at 100% RTP.
Annunciator ALB10-E06, RADIAL TILT, is lit.
I&C reports that the Quadrant Power Tilt Monitor alarm is inoperable.
Initiating Cue: The Shift Supervisor has directed you to, Perform 14915-1, Special Conditions Surveillance Logs, for QPTR Monitoring, including the completion of Section 7.0, Evaluation and Review, using the following provided data.
NI Channel Detector Current 1NI-41 A 409 mA 1NI-42 A 380 mA 1NI-43 A 450 mA 1NI-44 A 415 mA 1NI-41 B 430 mA 1NI-42 B 405 mA 1NI-43 B 445 mA 1NI-44 B 425 mA
Draft Admin RO JPM E RO Job Performance Measure Facility: Vogtle [verify page 5 info and code word on page 11]
Task No: V-LO-TA-40003 Task
Title:
Perform ERO Recall and ENN Notification JPM No: V-NRC-JP-NMP-EP-111-HL19 K/A
Reference:
G2.4.43 RO 3.2 Examinee: __________________________ NRC Examiner: _____________________
Facility Evaluator: ____________________ Date: ______________________________
Method of testing:
Simulated Performance ________________ Actual Performance ___________________
Classroom ______________ Simulator ______________ Plant _____________
Read to the examinee:
I will explain the initial conditions, which steps to simulate or discuss, and provide initiating cues.
When you complete the task successfully, the objective for this job performance measure will be satisfied.
THIS IS A TIME CRITICAL JPM Initial Conditions: Unit 1 has tripped due to a small LOCA.
The Shift Manager assumed the role of Emergency Director and declared an Alert Emergency.
WebEOC is NOT available.
Initiating Cue: The Emergency Director has directed you to, Perform the duties of the ENN Communicator and:
- 1) Perform an ERO recall per NMP-EP-111-003, Instruction 5 and;
- 2) Perform an ENN roll call for the MANUAL notification method per NMP-EP-111-F04 and;
- 3) Perform receipt confirmation of the MANUAL notification form per NMP-EP-111-F06.
1
Task Standard: Candidate completes the ERO recall, ENN roll call, and confirms receipt of the manual ENN form in accordance with the NMP-EP-111 instructions.
Required Materials: NMP-EP-111-003, Emergency Notification Communicator Instructions -
Vogtle (rev. 6.0)
NMP-EP-111-F04, Emergency Notifications Roll Call Instructions (rev.
1.0)
NMP-EP-111-F06, Manual Emergency Notification Transmission and Confirmation Instructions (rev. 1.0)
NMP-EP-111-F09, Plant Vogtle Emergency Notification Agency Listing (rev. 1.0)
NMP-EP-111-F10, SNC Emergency Notifications Form (ENF),
completed by the Exam Team for the candidate to transmit (rev. 1.0)
VEGP Emergency Recall Packet and Phone Book General
References:
None Time Critical Task: Yes Validation Time: 15 minutes Lines 1, 2, and 4 of the Emergency Notification Form (ENF) are marked critical in accordance with 60201-C, Simulator Training and Documentation, which requires satisfactory completion of these lines to meet the Emergency Preparedness Performance Indicator.
2
SIMULATOR SETUP:
- 1. Ensure the ENN telephone cord in the rear of the ENN telephone is labeled simulator and NOT the actual ENN phone cord.
- 2. Ensure the ENN telephone in the simulator booth is plugged into the phone jack and perform a test of the communications with the Shift Supervisor platform phone before JPM initiation.
- 3. Test the emergency recall phone number for an Alert Emergency prior to JPM initiation.
- 4. NMP-EP-111-F10, SNC Emergency Notifications Form (ENF), should be completed with the exception of Steps 2 (Notification Time and Date and Authentication #), 10 (Time), and 17 (Time) prior to the start of this JPM.
- 5. The start time of this JPM should be the time recorded in Step 10.
Setup time: 10 minutes 3
Performance Information Critical steps denoted with an asterisk and bolded.
NOTE TO EXAMINER: The examiner shall record the start time of the JPM on Line 10, which is the Declaration Time, on the Emergency Notification Form prior to providing it to the candidate.
Do NOT give the candidate the Emergency Notification Form at this time.
Candidate is given NMP-EP-111-003, NMP-EP-111-F04, NMP-EP-111-F06, and NMP-EP-F09 at this time.
Standard: N/A Comment:
BEGIN TIME CRITICAL NOTIFICATION: __________ (should be same time as Line 10 of Emergency Notification Form)
NMP-EP-111-003, Instruction 5, for activating the ERO recall NOTES
- ERO personnel should be recalled only if an Alert, Site Area Emergency or General Emergency has been declared or when directed by the Emergency Director.
- If the Alert, Site Area Emergency or General Emergency involves an actual or credible imminent threat of attack on the plant by a hostile force, then activate the Security Emergency Scenario.
- There is a three to four minute delay between initiating the emergency recall and the callback to the control room from the recall system.
Standard: Candidate reads NOTES prior to Step 1.
Comment:
4
- 1. Operations personnel shall activate the Primary emergency recall system in accordance with posted system instructions (Either NOUE or Alert/Site Area/General or Security Scenario as appropriate).
NOTE TO EXAMINER: The posted system instructions are in an envelope in the drawer to the left of the ENN phone.
Standard: Candidate selects the Primary emergency recall system packet from the drawer and correctly performs the following steps for an Alert emergency:
- Dial 706-554-4316.
- Enter Activation Password {93 49 87 50 90} followed by the # sign.
- Enter Scenario ID {917 566 662} followed by the # sign.
- Press {3} when prompted to start the scenario.
- Wait for the message, The scenario is building.
- Press the # sign and hang up.
Comment:
- 2. Operations personnel should verify the Primary emergency recall system is operable via a call back to the control room by the emergency recall system. In addition, the Shift Managers beeper should activate and display a predetermined emergency pager text message and a call-in number.
NOTE TO EXAMINER: The candidate should pick up the phone, speak any word, and hang up. The system will call back up to three times. This is normal.
Standard: Candidate verifies the Primary emergency recall system is operable via a return call (phone will ring shortly after recall system is activated).
Comment:
5
Steps 3, 4, and 5 activate the Backup emergency recall system and are not applicable.
- 6. Record date, time, and name below after completing the Instructions For Activation of the Vogtle Emergency Recall System as delineated within the posted instructions.
Standard: Candidate N/As Steps 3, 4, and 5, and records date, time, and name on Step 6.
Comment:
NMP-EP-111-F04, for performing the ENN roll call 1.0. Obtain a copy of the appropriate site specific procedure (NMP-EP-111-003).
Standard: Candidate checks that NMP-EP-111-003 is available.
Comment:
2.0. Select the appropriate instruction from the site specific document to operate the equipment for contacting the warning points or EOCs.
NOTE TO EXAMINER: The instruction for contacting the ENN agencies is found in NMP-EP-111-003, Instruction 6. This is a Reference Use procedure, so the candidate may refer to it as necessary.
Standard: Candidate refers to NMP-EP-111-003, Instruction 6, as necessary for establishing contact with the ENN agencies.
Comment:
6
3.0. Obtain a copy of the appropriate site specific Form for Applicable Agencies (NMP-EP-111-F09).
Standard: Candidate checks that NMP-EP-111-F09 is available.
Comment:
- 4.0. Establish contact on the ENN by performing a roll call of the applicable agencies. Each agency should be contacted. Check off each agency as acknowledgement is obtained.
NOTE TO EXAMINER: NMP-EP-111-003, Instruction 6, directs the candidate to establish contact with the ENN agencies as follows:
- Operation is accomplished by dialing a two digit calling code to call all stations or individual stations.
- Press ** on the ENN phone to ring ALL stations.
Standard: Candidate establishes contact on the ENN by pressing ** on the ENN phone to ring all stations.
Comment:
7
5.0. Perform roll call using step 5.1 for the electronic notification method or step 5.2 for the manual notification method.
5.2. When performing roll call for manual EN form transmission, read the following script:
THIS IS A [ DRILL ACTUAL EMERGENCY] MESSAGE.
THIS IS [YOUR NAME] _______________________ AT
[Plant FARLEY Plant HATCH Plant VOGTLE].
OBTAIN A BLANK EMERGENCY NOTIFICATION FORM AND STANDBY TO RECEIVE AN EMERGENCY NOTIFICATION MESSAGE USING THE MANUAL NOTIFICATION METHOD.
Standard: Candidate reads the script over the ENN phone with DRILL, candidates name, and VOGTLE inserted in the appropriate lines.
Comment:
6.0. Call each facility by name and confirm they are in standby.
NOTE TO EXAMINER: The facilities listed on NMP-EP-111-F09 are:
Burke County EMA Georgia Emergency Management (GEMA)
Savannah River Site (SRS)
South Carolina Emergency Management Division (SC-EMD)
Aiken County EMA Barnwell County EMA Allendale County EMA CUE: Simulator Operator will respond on the ENN phone as each agency is contacted.
Standard: Candidate calls each facility by name on the ENN phone to complete roll call.
Comment:
8
7.0. IF time allows, THEN agencies not contacted by the ENN should be contacted using the phone numbers provided.
8.0. IF ROLL CALL of the applicable agencies is not complete upon completion of the EN form, THEN terminate roll call and proceed to NMP-EP-111-F05 to perform receipt confirmation of the electronic EN form or NMP-EP-111-F06 to transmit the EN form manually.
Standard: N/A Comment:
CUE: Provide the Emergency Notification Form to the candidate at this time.
NMP-EP-111-F06, for performing manual notification and confirmation NOTES
- 1) All responsible state and local agencies must confirm receipt of the EN form within 15 minutes of the initial/upgrade emergency declaration or change in PARs.
- 2) IF an agency does not respond to the initial attempt to contact, THEN the remaining agencies listed should be contacted prior to any further attempts to contact the non-responsive agency.
1.0. Obtain a copy of the appropriate site specific procedure (NMP-EP-111-003).
Standard: Candidate reviews NOTES and checks that NMP-EP-111-003 is available.
Comment:
9
2.0. Select the appropriate instruction from the site specific document to operate the equipment for contacting the warning points or EOCs.
Standard: Candidate has already contacted the agencies, so no action is required.
Comment:
3.0. Obtain a copy of the appropriate site specific Form for Applicable Agencies (NMP-EP-111-F09).
Standard: Candidate checks that NMP-EP-111-F09 is available.
Comment:
4.0. IF ROLL CALL of the applicable agencies is not complete, THEN terminate roll call.
Standard: N/A Comment:
10
- 5.0. (Vogtle Only) IF any agency requires message authentication, THEN authenticate the message as follows:
- a. Enter the code provided by the requesting agency.
- c. Provide the authentication code supplied by the system to the agency requiring authentication verbally over the ENN.
CUE: Simulator Operator will respond on the ENN phone, South Carolina requests authentication for code word #27.
Standard: Candidate provides code word from the ENN Communicators packet (drawer to the left of the phone). NOTE: The code word will be provided to the examiner prior to the JPM administration.
Comment:
6.0. Read the following script:
THIS IS A [ DRILL ACTUAL EMERGENCY] MESSAGE.
THIS IS [YOUR NAME] _______________________ AT
[Plant FARLEY Plant HATCH Plant VOGTLE].
RECORD THE FOLLOWING INFORMATION ON YOUR BLANK EMERGENCY NOTIFICATION FOR EMERGENCY NOTIFICATION MESSAGE NUMBER
[MESSAGE NUMBER] _________.
Standard: Candidate reads the script over the ENN phone with DRILL, candidates name, VOGTLE, and Message #1 inserted in the appropriate lines.
Comment:
11
- 7.0. Transmit the EN Form data verbally as follows:
7.1. Read the notification form (line by line) through line 5, allowing ample time for the recipient to transfer the verbal data onto a blank form.
Line 1 - Block A, DRILL, and message #1 Line 2 - Block A, INITIAL, and Authentication #27 Line 3 - Site, VOGTLE, confirmation phone # (706) 826-3652 Line 4 - Emergency Classification, Block B, Alert, based on EAL #
FA1, EAL
Description:
Loss of RCS Barrier Line 5 - Protective Action Recommendations, Block A - NONE Standard: Candidate reads the EN Form data (line by line) through line 5 over the ENN phone. Lines 1 and 4 are critical.
Comment:
- 7.0. Transmit the EN Form data verbally as follows:
7.2. After reading line 5 of the EN Form, contact each required agency by name for the applicable site.
7.2.1. Record the TIME (HH:MM), DATE (mm/dd/yy), and name or operator number of the agency representative for each agency that acknowledges receipt of EN message through line 5 on the site specific agency notification form.
7.2.2. Record on line 2 of the EN Form the TIME (HH:MM) and DATE (mm/dd/yy) the first agency confirms receipt of the EN Form through line 5.
END TIME CRITICAL NOTIFICATION: __________ (should be same time as Line 2 of Emergency Notification Form)
Standard: Candidate contacts each facility to confirm receipt of the EN message and records the time and date that the first agency confirms receipt on Line 2 of the Emergency Notification Form.
Comment:
12
7.0. Transmit the EN Form data verbally as follows:
7.2. After reading line 5 of the EN Form, contact each required agency by name for the applicable site.
7.2.3. Direct the agencies to standby to receive the remainder of the information for the EN Form.
CUE: Another ENN Communicator will complete the remainder of the procedure.
Standard: N/A Comment:
Terminating cue: Candidate returns cue sheet and associated documentation.
13
Verification of Completion Job Performance Measure No.: V-NRC-JP-NMP-EP-111-HL19 Examinees Name:
Examiners Name:
Date Performed:
Number of Attempts:
Time to Complete:
Question Documentation:
Question: __________________________________________________________________
Response: _________________________________________________________________
Result: Satisfactory / Unsatisfactory Examiners signature and date: _______________________________ _________
14
15 THIS IS A TIME CRITICAL JPM Initial Conditions: Unit 1 has tripped due to a small LOCA.
The Shift Manager assumed the role of Emergency Director and declared an Alert Emergency.
WebEOC is NOT available.
Initiating Cue: The Emergency Director has directed you to, Perform the duties of the ENN Communicator and:
- 1) Perform an ERO recall per NMP-EP-111-003, Instruction 5 and;
- 2) Perform an ENN roll call for the MANUAL notification method per NMP-EP-111-F04 and;
- 3) Perform receipt confirmation of the MANUAL notification form per NMP-EP-111-F06.
Draft RO/SRO Admin JPM A RO / SRO Job Performance Measure Facility: Vogtle Task No: V-LO-TA-37026 Task
Title:
Determine Maximum Allowable Venting Time for Venting Voids in the Reactor Vessel JPM No: V-NRC-JP-19263-HL19 K/A
Reference:
G2.1.25 RO 3.9 SRO 4.2 Examinee: ___________________________ NRC Examiner: _________________
Facility Evaluator: ______________________ Date: _________________________
Method of testing:
Simulated Performance ______________ Actual Performance ____________________
Classroom ______________ Simulator _______________ Plant __________________
Read to the examinee:
I will explain the initial conditions, which steps to simulate or discuss, and provide initiating cues.
When you complete the task successfully, the objective for this job performance measure will be satisfied.
Initial Conditions: Unit 2 has experienced a LOCA.
RCS pressure is recovering and the control room crew has transitioned to 19263-C, Response to Voids in Reactor Vessel, due to low RVLIS level.
Initiating Cue: The Shift Supervisor has directed you to, Use the data provided below to determine the maximum allowable venting time by completing ATTACHMENT 3 of 19263-C.
Indicator Value UT-2501 140° F AR-12979 2.0%
PI-408 795 psig PI-418 800 psig PI-428 790 psig PI-438 795 psig 1
Task Standard: Candidate correctly determines the maximum allowable venting time using Attachment 3 of 19263-C, Response to Voids in Reactor Vessel.
Required Materials: Attachment 3 and Figure 1 of 19263-C, Response to Voids in Reactor Vessel (rev. 22)
Calculator Ruler or straight edge General
References:
None Time Critical Task: No Validation Time: 12 minutes 2
Performance Information Critical steps denoted with an asterisk and bolded.
- Determine maximum allowable venting time.
Standard: Candidate correctly determines maximum allowable venting time of 1.13 [+/- 0.1] minutes by completing Attachment 3 of 19263-C, Response to Voids in Reactor Vessel.
NOTE TO EXAMINER: The Answer Key is on the following pages.
Comment:
Terminating cue: Candidate returns initiating cue sheet.
3
ATTACHMENT 3 ANSWER KEY (DO NOT PROVIDE TO CANDIDATES) 1
- 1. Determine Containment Volume at Standard Temperature and Pressure:
1.a
- a. Record Containment Temperature (°F).
(Plant Computer Point UT-2501) 140 [+/- 0]
1.b
- b. Convert using Rankine Temperature:
492 / (1.a. + 460) = 0.82 [+/- 0.02]
1.c
- c. Calculate CNMT Volume at STP:
(2.75E6 Cu. ft.) x (1.b.) = 2.255E6 [+/- 1E5]
2
- 2. Determine the maximum H2 (hydrogen) volume that can be safely vented:
2.a
- a. Record Containment H2 reading in percent.
(AI-12979 or AI-12980 or AR-12979) 2 [+/- 0]
2.b
- b. Determine H2 concentration margin:
[3.0% - (2.a.)] / 100% = 0.01 [+/- 0]
2.c
- c. Calculate maximum volume:
(2.b.) x (1.c.) = 22550 [+/- 1000]
3
- 3. Determine H2 Vent Flow rate as a function of RCS pressure:
3.a
- a. Record RCS pressure using highest reading meter. 800 [+/- 0]
- PI-408
- PI-418
- PI-428
- PI-438 3.b
- b. Use FIGURE 1 to determine H2 Flow rate. 20000 [+/- 1000]
4
- 4. Calculate maximum venting time:
4.a
- a. Maximum Venting time:
(2.c.) / (3.b.) = 1.13 [+/- 0.1] minutes END OF ATTACHMENT 3 4
FIGURE 1 ANSWER KEY (DO NOT PROVIDE TO CANDIDATES) 2500 2250 R 2000 C
S 1750 P
R 1500 E
S S 1250 U
R E 1000 P
750 S
I G 500 250 0
0 10 20 30 40 50 60 C = HYDROGEN FLOW RATE in SCFM (x 1000)
FIGURE 1 HYDROGEN FLOW RATE VERSUS RCS PRESSURE 5
Verification of Completion Job Performance Measure No.: V-NRC-JP-19263-HL19 Examinees Name:
Examiners Name:
Date Performed:
Number of Attempts:
Time to Complete:
Question Documentation:
Question: ______________________________________________________________
Response: _____________________________________________________________
Result: Satisfactory / Unsatisfactory Examiners signature and date: ____________________________ ___________
6
Initial Conditions: Unit 2 has experienced a LOCA.
RCS pressure is recovering and the control room crew has transitioned to 19263-C, Response to Voids in Reactor Vessel, due to low RVLIS level.
Initiating Cue: The Shift Supervisor has directed you to, Use the data provided below to determine the maximum allowable venting time by completing ATTACHMENT 3 of 19263-C.
Indicator Value UT-2501 140° F AR-12979 2.0%
PI-408 795 psig PI-418 800 psig PI-428 790 psig PI-438 795 psig
Draft RO/SRO Admin JPM B RO / SRO Job Performance Measure Facility: Vogtle Task No: V-LO-TA-37002 Task
Title:
Calculate Amount of Boric Acid Required for Three Stuck Rods JPM No: V-NRC-JP-19001-HL19 K/A
Reference:
G2.1.23 RO 4.3 SRO 4.4 Examinee: __________________________ NRC Examiner: ______________________
Facility Evaluator: ____________________ Date: ______________________________
Method of testing:
Simulated Performance ________________ Actual Performance ___________________
Classroom ______________ Simulator ______________ Plant _____________
Read to the examinee:
I will explain the initial conditions, which steps to simulate or discuss, and provide initiating cues.
When you complete the task successfully, the objective for this job performance measure will be satisfied.
Initial Conditions: Unit 1 is in Mode 3 following a manual reactor trip.
The RCS is at 500° F and 1600 psig.
RCS boron concentration is 400 ppm.
BAST boron concentration is 7300 ppm.
DRPI indicates the following rod positions:
- Shutdown Bank A, Rod D2 is at 216 steps.
- Shutdown Bank B, Rod C9 is at 18 steps.
- Shutdown Bank D, Rod E13 is at 192 steps.
The operating crew is at Step 8 of 19001-C, Reactor Trip Response.
Initiating Cue: The Shift Supervisor has directed you to, Determine the amount of boric acid in gallons that must be added to the RCS for the current plant conditions in accordance with 19001-C, Step 8 RNO.
1
Task Standard: Candidate correctly determines that 4506 gallons (+/- 1 gallon) of boric acid must be added to the RCS for the three stuck rods.
Required Materials: Calculator Plant Technical Data Book, Tab 2 19001-C, Reactor Trip Response, Step 8 (rev. 34.2)
General
References:
None Time Critical Task: No Validation Time: 8 minutes 2
Performance Information Critical steps denoted with an asterisk and bolded.
19001-C, Reactor Trip Response
- 8. Check all Rods - FULLY INSERTED.
Standard: Candidate determines from initial conditions that all rods are NOT fully inserted.
Comment:
- 8. RNO IF two or more Rods NOT fully inserted, THEN EMERGENCY BORATE 154 ppm for each Rod not fully inserted by initiating 13009-1, CVCS Reactor Makeup Control System.
Standard: Candidate determines for three stuck rods boron concentration will have to be raised (154 ppm/rod)(3 rods) = 462 ppm [+/- 0 ppm].
Comment:
- Calculate the required gallons of boric acid using PTDB, Tab 2.0.
NOTE TO EXAMINER: This equation is on each of the Boron Addition Tables in Tab 2.0.
Standard: Candidate determines 4251 gallons [+/- 1 gallon] of boric acid are required.
61346 gallons x ln[(7300 - 400) ÷ (7300 - 862)] = 4251 gallons [+/- 1 gallon]
Comment:
3
- Apply correction factor of 1.06 from PTDB, Tab 2.1, per NOTE at bottom of all Tab 2.3 pages.
Standard: Candidate applies correction factor of 1.06 and determines 4506 gallons [+/-
1 gallon] of boric acid are required.
4251 gallons x 1.06 = 4506 gallons [+/- 1 gallon] of boric acid.
Comment:
Terminating cue: Candidate returns initiating cue sheet.
4
Verification of Completion Job Performance Measure No.: V-NRC-JP-19001-HL19 Examinees Name:
Examiners Name:
Date Performed:
Number of Attempts:
Time to Complete:
Question Documentation:
Question: __________________________________________________________________
Response: _________________________________________________________________
Result: Satisfactory / Unsatisfactory Examiners signature and date: _______________________________ ____________
5
Initial Conditions: Unit 1 is in Mode 3 following a manual reactor trip.
The RCS is at 500° F and 1600 psig.
RCS boron concentration is 400 ppm.
BAST boron concentration is 7300 ppm.
DRPI indicates the following rod positions:
- Shutdown Bank A, Rod D2 is at 216 steps.
- Shutdown Bank B, Rod C9 is at 18 steps.
- Shutdown Bank D, Rod E13 is at 192 steps.
The operating crew is at Step 8 of 19001-C, Reactor Trip Response.
Initiating Cue: The Shift Supervisor has directed you to, Determine the amount of boric acid in gallons that must be added to the RCS for the current plant conditions in accordance with 19001-C, Step 8 RNO.
Draft SRO Admin JPM C NRC SRO Admin Job Performance Measure Facility: Vogtle Task No: V-LO-TA-17007 Task
Title:
Perform and Evaluate Quadrant Power Tilt Ratio Surveillance for Inoperable QPTR Monitor Alarm JPM No: V-NRC-JP-14915-HL19 K/A
Reference:
G2.2.12 RO 3.7 SRO 4.1 Examinee: ___________________________ NRC Examiner: ____________________
Facility Evaluator: _____________________ Date: ____________________________
Method of testing:
Simulated Performance _________________ Actual Performance _____________________
Classroom ________________ Simulator ___________________ Plant ________________
Read to the examinee:
I will explain the initial conditions, which steps to simulate or discuss, and provide initiating cues.
When you complete the task successfully, the objective for this job performance measure will be satisfied.
Initial Conditions: Unit 1 is at 100% RTP.
You just started your 12-hour shift.
Annunciator ALB10-E06, RADIAL TILT, is lit.
I&C reports that the Quadrant Power Tilt Monitor alarm is inoperable.
Initiating Cue: The Shift Supervisor has directed you to, Perform 14915-1, Special Conditions Surveillance Logs, for QPTR Monitoring, including the completion of Section 7.0, Evaluation and Review, using the following provided data.
1
NI Channel Detector Current 1NI-41 A 409 mA 1NI-42 A 380 mA 1NI-43 A 450 mA 1NI-44 A 415 mA 1NI-41 B 430 mA 1NI-42 B 405 mA 1NI-43 B 445 mA 1NI-44 B 425 mA Based on the results of the surveillance, is any Tech Spec LCO NOT met?
If any Tech Spec LCO is NOT met, THEN determine all Tech Spec REQUIRED ACTIONS to be performed during your shift, if any, for the given plant conditions.
2
Task Standard: Candidate performs QPTR calculation correctly using 14915-1, Data Sheet 7, and determines the upper value is 1.03 (> 1.02). Candidate then evaluates the data to determine the correct Tech Spec applicable actions.
Required Materials: 14915-1, Special Condition Surveillance Logs (rev. 48.1)
Unit 1 Plant Technical Data Book, Tab 5.0 (rev. 159)
Tech Specs and Tech Spec Bases Calculator Red Ink Pen, if requested General
References:
None Time Critical Task: No Validation Time: 16 minutes 3
Performance Information Critical steps denoted with an asterisk and bolded.
DATA SHEET 7 Sheet 1 of 2 QUADRANT POWER TILT RATIO NOTES
- The arrangement of the NI rack layout is Channel I, II, IV, and III.
- If ALB 10 D02 or E02 annunciate and power is less than 50% performance of this data sheet is not required.
- If ALB 10 E06 annunciates and power is less than 10% performance of this data sheet is not required.
- Prior to taking readings from the upper and lower detector meters, change scales on the RANGE MILLI-AMPS Switch and then return it to its original position. This will wipe the switch contacts giving a more accurate reading.
- 1. Calculate and record Quadrant Power Tilt Ratio at least once per 12 hours1.388889e-4 days <br />0.00333 hours <br />1.984127e-5 weeks <br />4.566e-6 months <br /> using Sheet 2. PC based spreadsheet may be used for QPTR calculation if normalization factors used are verified current with the PTDB Tab 5.0 revision. If performing a manual calculation, compare PTDB Tab 5.0 with the PC Spreadsheet (if the PC is available) to verify normalization factors.
CUE: If candidate requests TILT DEVIATION from engineering, Perform procedure with the information provided.
Standard: Candidate reviews NOTES and step. PC Spreadsheet is not available.
Comment:
4
- 2. With one Power Range NI inoperable, obtain TILT DEVIATION from Reactor Engineering as determined from moveable incore detectors and verify it is within
+/-0.02 of QPTR obtained from the operable power range NIs. (Use avg. and max. of 3 operable NIs)
CUE: If candidate requests TILT DEVIATION from engineering, Perform procedure with the information provided.
Standard: Candidate reviews step. No Power Range NI is inoperable.
Comment:
NOTE A Fluke 8050A Digital Multimeter may be used to obtain more accurate current values for calculation of QPTR.
- 3. If a Fluke 8050A Digital Multimeter will be used to obtain current values from the NI Drawer, record instrument information below.
Instrument ID No._______________________
Cal Due Date__________________________
Standard: Candidate reviews step and determines a Multimeter will not be used.
Comment:
- 4. Verify Quadrant Power Tilt Ratio is less than or equal to 1.02.
Standard: Candidate calculates the Quadrant Power Tilt Ratio using Sheet 2 of Data Sheet 7 and determines the upper value is 1.03 (> 1.02). NOTE: Rounding to three significant digits is not critical.
Comment:
5
- 5. With Quadrant Power Tilt Ratio greater than 1.02, initiate action in accordance with Technical Specification LCO 3.2.4 and continue to calculate and record QPTR once every 12 hours1.388889e-4 days <br />0.00333 hours <br />1.984127e-5 weeks <br />4.566e-6 months <br /> on sheet 2.
The Tech Spec LCO 3.2.4 REQUIRED ACTION for QPTR > 1.02 is to limit THERMAL POWER to 3% below RTP for each 1% of QPTR > 1.00 within 2 hours2.314815e-5 days <br />5.555556e-4 hours <br />3.306878e-6 weeks <br />7.61e-7 months <br />. With calculated QPTR = 1.03, a power reduction to at least 9% below RTP (100% - 9% = 91%) is required.
NOTE TO EXAMINER: LCO 3.2.4 includes additional required actions to perform periodic manual QPTR calculations and to perform other surveillances after the thermal power reduction. These actions are NOT necessary to successfully complete the critical step, which is to initiate action in accordance with Technical Specification LCO 3.2.4.
Standard: Candidate determines a power reduction to 9% below RTP (91%) is required.
Comment:
Terminating cue: Candidate returns initiating cue sheet.
6
7 8
(ANSWER KEY - DO NOT PROVIDE TO CANDIDATES)
DATA SHEET 7 Sheet 2 of 2 DATE ____Today_____
TIME ____Now_______
NI Channel Detector Current Factor*
41 A _409 mA_ x _1.112_ = _454.808_ (1) 42 A _380 mA_ x _1.108_ = _421.040_ (1) 43 A _450 mA_ x _1.025_ = _461.250_ (1) 44 A _415 mA_ x _1.096_ = _454.840_ (1)
Avg = _447.985_ (1)
QPTR (Upper) = Max(upper) = _1.03_(2)
Avg(upper)
NI Channel Detector Current Factor*
41 B _430 mA_ x _1.058_ = _454.940_ (1) 42 B _405 mA_ x _1.071_ = _433.755_ (1) 43 B _445 mA_ x _1.000_ = _445.000_ (1) 44 B _425 mA_ x _1.052_ = _447.100_ (1)
Avg = _445.199_ (1)
QPTR (Lower) = Max(lower) = _1.02_(2)
Avg(lower)
QPTR = Max of QPTR(upper) or QPTR(lower) = _1.03__
TILT DEVIATION = _N/A_
(from Reactor Engineering if applicable)
COMPLETED BY ____Candidate_______
Shift Supervisor Review: ______________/____________/____________
Initial Date Time
- Factor = Normalization Factor from Plant Technical Data Book tab 5.0 Note 1 = Calculations should be performed to 3 decimal places Note 2 = Round to 2 decimal places (if the 3rd decimal is 5 round up, if 3rd decimal is <5, round down) 9
(ANSWER KEY - DO NOT PROVIDE TO CANDIDATES) 7.0 EVALUATION AND REVIEW 7.1 TEST PURPOSE Special Condition(s):
______Quadrant Power Tilt Monitor alarm is inoperable____________
Data Sheet(s) completed (Circle Appropriate Sheets):
1 2 3 4a 4b 5 6 7 8 9 10 11 12 13 14 15 16 17 18 7.2 Results obtained through the performance of this procedure meet the ACCEPTANCE CRITERIA of Section 6.0.
YES NO 7.3 IF no was checked, immediately notify the SS and initiate action in accordance with the actions specified on the data sheet(s) not meeting the acceptance criteria.
7.4 Comments (include any abnormal conditions and corrective actions taken):
___________Upper QPTR exceeds 1.02_________________________
Test Completed and SS Notified: ________________ __________ __________
Supervisory Review: ________________ __________ __________
Signature Date Time 10
Verification of Completion Job Performance Measure No.: V-NRC-JP-14915-HL19 Examinees Name:
Examiners Name:
Date Performed:
Number of Attempts:
Time to Complete:
Question Documentation:
Question: ______________________________________________________________
Response: _____________________________________________________________
Result: Satisfactory / Unsatisfactory Examiners signature and date: ____________________________ __________
11
Initial Conditions: Unit 1 is at 100% RTP.
You just started your 12-hour shift.
Annunciator ALB10-E06, RADIAL TILT, is lit.
I&C reports that the Quadrant Power Tilt Monitor alarm is inoperable.
Initiating Cue: The Shift Supervisor has directed you to, Perform 14915-1, Special Conditions Surveillance Logs, for QPTR Monitoring, including the completion of Section 7.0, Evaluation and Review, using the following provided data.
NI Channel Detector Current 1NI-41 A 409 mA 1NI-42 A 380 mA 1NI-43 A 450 mA 1NI-44 A 415 mA 1NI-41 B 430 mA 1NI-42 B 405 mA 1NI-43 B 445 mA 1NI-44 B 425 mA Based on the results of the surveillance, is any Tech Spec LCO NOT met?
If any Tech Spec LCO is NOT met, THEN determine all Tech Spec REQUIRED ACTIONS to be performed during your shift, if any, for the given plant conditions.
Draft SRO Admin JPM D NRC SRO Admin Job Performance Measure Facility: Vogtle Task No: N/A Task
Title:
Assess Radiological Conditions in an Emergency and Determine if a Task Can be Performed JPM No: V-NRC-JP-91301-HL19 K/A
Reference:
G2.3.14 SRO 3.8 Examinee: ___________________________ NRC Examiner: _____________________
Facility Evaluator: _____________________ Date: ______________________________
Method of testing:
Simulated Performance ________________ Actual Performance ___________________
Classroom ______________ Simulator ______________ Plant _____________
1
Read to the examinee:
I will explain the initial conditions, which steps to simulate or discuss, and will provide initiating cues.
When you complete the task successfully, the objective for this job performance measure will be satisfied.
Initial Conditions: Unit 1, SG #1 has a tube rupture, and SGs #2 and #4 have tube leaks.
Chemistry samples indicate fuel failure has occurred.
A General Emergency has been declared with site boundary doses exceeding PAGs.
SGs #1, #2, and #4 ARVs have failed open and are required to be isolated.
A Systems Operator (SO) is assigned to manually isolate the ARVs.
The SO has an accumulated year-to-date dose of 960 mrem.
The SO is NOT a volunteer.
The following times are required to close each manual ARV isolation valve:
TASK ESTIMATED TIME Isolate 1PV-3000 (loop 1 ARV) 15 minutes Isolate 1PV-3010 (loop 2 ARV) 20 minutes Isolate 1PV-3030 (loop 4 ARV) 18 minutes NOTE: Assume no dose is received while traveling between tasks and that the actual completion times are the same as the estimated times.
Initiating Cue: You are the Emergency Director. Based on the given conditions and using the survey maps provided, answer the following questions:
- a. What is the Emergency Exposure Limit for the Systems Operator to perform the tasks listed above?
- b. Can the Systems Operator complete all of the tasks listed above without exceeding the applicable Emergency Exposure Limit?
2
Task Standard: Upon successful completion of this JPM, the candidate will correctly:
- 2. Determine if the tasks can be performed without exceeding the Emergency Exposure Limit.
Required Materials: Calculator ARV valve room survey maps General
References:
91301-C, Emergency Exposure Guidelines Time Critical Task: No Validation Time: 16 minutes NOTE TO EXAMINER: JPM Knowledge of the Emergency Exposure Limits is an SRO-Only objective.
V-LO-LP-40101-34: State the emergency TEDE limits for the following (SRO only):
- a. All activities
- b. Protecting valuable property
- c. Lifesaving actions or protection of large populations 3
Performance Information Critical steps denoted with an asterisk and bolded.
- Determine applicable Emergency Exposure Limit.
Given a General Emergency with three failed fission product barriers, closure of the open ARVs will limit the exposure to a large population. Since the Systems Operator is NOT a volunteer, the Emergency Exposure Limit is 25 rem.
Isolating the ARVs is not done to protect equipment or property, which would have an Emergency Exposure Limit of 10 rem.
Standard: Candidate determines that the applicable Emergency Exposure Limit for the task is 25 rem.
Comment:
Using the correct survey map, a dose rate of 16 rem/hour at the valve is determined.
The valve operation will take 15 minutes.
16 rem/hour (1 hour1.157407e-5 days <br />2.777778e-4 hours <br />1.653439e-6 weeks <br />3.805e-7 months <br /> / 60 minutes) (15 minutes) = 4 rem [no range on calculated value]
Standard: Candidate calculates dose to isolate 1PV-3000 to be 4 rem [no range on final value].
Comment:
4
Using the correct survey map, a dose rate of 48 rem/hour at the valve is determined.
The valve operation will take 20 minutes.
48 rem/hour (1 hour1.157407e-5 days <br />2.777778e-4 hours <br />1.653439e-6 weeks <br />3.805e-7 months <br /> / 60 minutes) (20 minutes) = 16 rem [no range on calculated value]
Standard: Candidate calculates dose to isolate 1PV-3010 to be 16 rem [no range on final value].
Comment:
Using the correct survey map, a dose rate of 14 rem/hour at the valve is determined.
The valve operation will take 18 minutes.
14 rem/hour (1 hour1.157407e-5 days <br />2.777778e-4 hours <br />1.653439e-6 weeks <br />3.805e-7 months <br /> / 60 minutes) (18 minutes) = 4.2 rem [no range on calculated value]
Standard: Candidate calculates dose to isolate 1PV-3010 to be 4.2 rem [no range on final value].
Comment:
5
- Determine if the Emergency Exposure Limit will be exceeded.
Total calculated dose received would be:
4 rem + 16 rem + 4.2 rem = 24.2 rem (non-emergency exposure is not added)
Standard: Candidate determines that the total dose received (24.2 rem) will NOT exceed the Emergency Exposure Limit (25 rem) for the tasks performed.
Comment:
Terminating cue: Candidate returns initiating cue sheet.
6
Verification of Completion Job Performance Measure No.: V-NRC-JP-91301-HL19 Examinees Name:
Examiners Name:
Date Performed:
Number of Attempts:
Time to Complete:
Question Documentation:
Question: __________________________________________________________________
Response: _________________________________________________________________
Result: Satisfactory / Unsatisfactory Examiners signature and date: _______________________________ ________
7
Initial Conditions: Unit 1, SG #1 has a tube rupture, and SGs #2 and #4 have tube leaks.
Chemistry samples indicate fuel failure has occurred.
A General Emergency has been declared with site boundary doses exceeding PAGs.
SGs #1, #2, and #4 ARVs have failed open and are required to be isolated.
A Systems Operator (SO) is assigned to manually isolate the ARVs.
The SO has an accumulated year-to-date dose of 960 mrem.
The SO is NOT a volunteer.
The following times are required to close each manual ARV isolation valve:
TASK ESTIMATED TIME Isolate 1PV-3000 (loop 1 ARV) 15 minutes Isolate 1PV-3010 (loop 2 ARV) 20 minutes Isolate 1PV-3030 (loop 4 ARV) 18 minutes NOTE: Assume no dose is received while traveling between tasks and that the actual completion times are the same as the estimated times.
Initiating Cue: You are the Emergency Director. Based on the given conditions and using the survey maps provided, answer the following questions:
- a. What is the Emergency Exposure Limit for the Systems Operator to perform the tasks listed above?
- b. Can the Systems Operator complete all of the tasks listed above without exceeding the applicable Emergency Exposure Limit?
Draft SRO Admin JPM E SRO Admin Job Performance Measure Facility: Vogtle Task No: V-LO-TA-40002 Task
Title:
Classify an Emergency Event and Complete the Emergency Notification Form JPM No: V-NRC-JP-NMP-EP-110-HL19 K/A
Reference:
G2.4.41 SRO 4.6 Examinee: ________________________________ NRC Examiner: __________________
Facility Evaluator: ___________________________ Date: __________________________
Method of testing:
Simulated Performance ________________ Actual Performance ____________________
Classroom __________________ Simulator __________________ Plant ______________
Read to the examinee:
I will explain the initial conditions, which steps to simulate or discuss, and provide initiating cues. When you complete the task successfully, the objective for this job performance measure will be satisfied.
THIS IS A TIME CRITICAL JPM Initial Conditions: The Unit 1 seismic monitoring system confirmed a seismic event with an earthquake acceleration of 0.14 g.
Unit 1 is in Mode 3 following a reactor trip and Safety Injection 20 minutes ago due to 275 gpm RCS leakage.
Unit 1 containment pressure relief was in progress, and can NOT be isolated.
1RE-005 and 1RE-006 are both indicating 2.6 E+4 mr/hr.
Wind direction (10 meter, 15 min. avg.) is currently 20º at 4.5 mph.
Stability class is D with no precipitation.
WebEOC is NOT functional.
The ENN Communicator has completed recall and roll call.
1
Initiating Cue: You are the Emergency Director, and based on the given conditions, complete Checklist 1, Classification Determination, of NMP-EP-110, Emergency Classification Determination and Initial Action, through Step 6 to determine the HIGHEST emergency classification level, AND complete NMP-EP-111-F10, SNC Emergency Notifications Form (ENF),
for the declared emergency.
Classify the Unit 1 emergency only. Consider Unit 2 unaffected.
2
Task Standard: Candidate correctly declares a Site Area Emergency within 15 minutes and completes the Emergency Notification Form (NMP-EP-111-F10) within an additional 15 minutes. No PARs are required for the classification.
Required Materials: NMP-EP-110, Emergency Classification Determination and Initial Action (rev. 6.1)
NMP-EP-110-GL03, VEGP EALs - ICs, Threshold Values and Basis, Figures 1, 2, and 3 (rev. 4.0)
NMP-EP-111, Emergency Notifications (rev. 8.0)
NMP-EP-111-003, Emergency Notification Communicator Instructions -
Vogtle (rev. 6.0)
NMP-EP-111-F10, SNC Emergency Notifications Form (ENF) (rev. 1.0)
NMP-EP-112, Protective Action Recommendations (rev. 3.0)
General
References:
None Time Critical Task: YES Validation Time: 30 minutes (15 minutes to declare the emergency and 15 minutes to notify authorities by completing the Emergency Notification Form)
Lines 1, 2, 4, 5, 6, and 10 of the Emergency Notification Form (ENF) are critical based on 60201-C, Simulator Training and Documentation, which requires satisfactory completion of these lines to meet the Emergency Preparedness Performance Indicator.
Line 17 is critical based on the time requirement of NMP-EP-111, Emergency Notifications, to notify State and Local Agencies within 15 minutes of the declaration of an emergency.
3
Performance Information Critical steps are denoted with an asterisk and bolded.
BEGIN TIME CRITICAL FOR CLASSIFICATION DETERMINATION: ______
(time JPM begins)
NMP-EP-110, Checklist 1 - Classification Determination NOTE Key Parameters should be allowed to stabilize to accurately represent plant conditions prior to classifying an event.
Initial Actions
- 1. Determine the appropriate Initiating Condition Matrix for classification of the event based on the current operating mode:
HOT IC/EAL Matrix Evaluation Chart (Go To Step 2) to evaluate the Barriers COLD IC/EAL Matrix Evaluation Chart (Go To Step 3)
Both HOT & COLD IC/EAL Matrix Evaluation Chart apply (Go To Step 2)
Standard: Candidate selects the HOT IC/EAL Matrix to evaluate the barriers.
Comment:
- 2. Evaluate the status of the fission product barrier using Figure 1, Fission Product Barrier Evaluation.
- a. Select the condition of each fission product barrier:
LOSS POTENTIAL LOSS INTACT Fuel Cladding Integrity Reactor Coolant System Containment Integrity Standard: Candidate checks loss of RCS barrier (1RE-005/006 > 2.0 E+4 mr/hr) and loss of Containment Integrity barrier (purge dampers will not close). Fuel Cladding Integrity is intact.
Comment:
4
- 2. Evaluate the status of the fission product barrier using Figure 1, Fission Product Barrier Evaluation.
- b. Determine the highest applicable fission product barrier Initiating Condition (IC):
(select one) FG1 FS1 FA1 FU1 None Standard: Candidate selects FS1 for Loss or Potential Loss of ANY Two Barriers. NOTE:
This information is found at the top of Figure 1.
Comment:
- 3. Evaluate AND determine the highest applicable IC/EAL using the Matrix Evaluation Chart(s) identified in Step 1, THEN go to Step 4.
Hot IC# __FS1__ Unit __1__ and/or Cold IC# ______ Unit _____ or None Standard: Candidate determines that the highest IC/EAL is FS1 (Site Area) based on the Fission Product Barrier Evaluation, which is higher than HA1 (Alert based on seismic event > 0.12 g) from the HOT IC/EAL Matrix Evaluation Chart, Figure 2.
Comment:
- 4. Check the highest emergency classification level identified from either Step 2b or 3:
Classification Based on IC# Classification Based on IC#
General ___________ Alert __________
Site-Area FS1 NOUE __________
None N/A___
Remarks (Identify the specific EAL, as needed): ________________________
Standard: Candidate checks the Site Area Classification block and records IC# FS1.
Remarks line may be N/A or include the EAL.
Comment:
5
- 5. Declare the event by approving the Emergency Classification.
____________________ Date: _______/_______/_______ Time: _______
Emergency Director Standard: Candidate signs as Emergency Director and records the current date and time.
NOTE: The critical step is making the declaration within 15 minutes.
END TIME CRITICAL FOR CLASSIFICATION DETERMINATION: _______
(time of emergency declaration on Line 5)
Comment:
- 6. Obtain Meteorological Data (not required prior to event declaration):
Wind Direction (from) __20o____ Wind Speed __4.5____
Stability Class __D____ Precipitation __None__
Standard: Candidate obtains meteorological data from Initial Conditions.
Comment:
- 7. Initiate Attachment 2, Checklist 2 - Emergency Plan Initiation.
Standard: N/A. Per the Initiating Cue, candidate is required to complete Checklist 1 through Step 6, and then complete NMP-EP-111-F10, SNC Emergency Notifications Form (ENF).
Comment:
6
NMP-EP-111-F03, Plant Vogtle Emergency Notification Form Completion Instructions, provides guidance for Emergency Notifications Form (ENF) completion.
NOTE TO EXAMINER: NMP-EP-111-F03 is an Information Use procedure, so the candidate is not required to read the instructions line-by-line. The candidate may refer to it as necessary. The JPM includes all of the steps, but the task standard is correct completion of NMP-EP-111-F10 (Emergency Notifications Form), not that each individual step of NMP-EP-111-F03 is read and marked.
Standard: Candidate refers to NMP-EP-111-F03 as required to complete NMP-EP-111-F10.
Comment:
BEGIN TIME CRITICAL FOR EMERGENCY NOTIFICATION FORM:
___________ (same time as emergency declaration)
- 1.0. Line 1: Enter MESSAGE NUMBER. MESSAGE NUMBER is automatically assigned during the transmittal process if using the electronic EN Form tool.
Message numbers are sequential for the duration of the Event.
Standard: Candidate marks Block A (DRILL) and enters MESSAGE #1.
Comment:
- 2.0. Line 2: Select the appropriate message type. INITIAL will be checked for any notification associated with the declaration and/or change of an emergency classification (including Termination).
Standard: Candidate marks Block A (INITIAL). NOTE: Notification time and authentication number will be completed by the ENN communicator at a later time.
Comment:
7
3.0. Line 3: Enter or confirm the correct site and site call back number is displayed.
When using the electronic form the site location is automatically completed based on prior selections.
Standard: Candidate enters Vogtle for the site. NOTE: On the in-plant forms, the Vogtle phone number is already filled in.
Comment:
- 4.0. Line 4: Select the appropriate EAL from the drop down list (For Termination, Select Termination). Confirm the brief description of the initiating conditions for the emergency classification declared is auto completed based on the EAL number selected. The event description block cannot be edited. Additional information or information relative to competing events should be included on Line 13, REMARKS.
Standard: Candidate marks Block C (SITE AREA EMERGENCY), enters EAL # FS1, and provides a brief EAL description (Loss or Potential Loss of ANY Two Barriers -
or similar wording).
Comment:
- 5.0. Line 5: Complete Lines 5B, 5C, 5D, 5E.
Standard: Candidate marks Block A (NONE) since PARs are not required for a Site Area emergency.
Comment:
8
NOTES Information for Lines 6, 7, and 9 are obtained from dose assessment (e.g., Dose Assessment Staff in either the TSC or the EOF, as appropriate).
IF an effluent monitor is out of service or failed, THEN an increased attention to detail is required when item 6 and 7 tables are evaluated.
- 6.0 Line 6: Select the appropriate box for EMERGENCY RELEASE using the following table to determine the status of a radiological release:
IF: THEN:
FMT readings or Dose assessment results (automated or manual) have been completed AND indicate an emergency radiological Check B Is Occurring release is underway At least one of the following effluent monitors is in alarm, AND completed dose projection results (automated or manual) are not Check B Is Occurring available: RE-12444C, RE-12444D, RE-12444E, RE-12839C, RE-12839D, RE-12839E, RE-16980A Conditions exist indicating that a radiological release is occurring based on plant conditions (e.g. SGTR with known path to the environment, site specific effluent radiation monitor readings, FMT Check B Is Occurring readings, etc.)
Elevated indications do not exist on any of the following effluent monitor: RE-12444C, RE-12444D, RE-12444E, RE- Check A None 12839C, RE-12839D, RE-12839E, RE-16980A Dose assessment results (automated or manual) have been completed AND indicate an emergency radiological release is NOT Check A None underway Dose assessment results indicate an emergency radiological Check C Has Occurred release occurred previously AND is no longer underway Standard: Candidate marks Block A (None) since no release is occurring.
Comment:
9
7.0. Line 7: Select the appropriate box for RELEASE SIGNIFICANCE using the following table to determine the release significance:
IF: THEN:
Elevated indications do not exist on any of the following effluent monitor: RE-12444C, RE-12444D, RE-12444E, RE-12839C, RE- Check A Not applicable 12839D, RE-12839E, RE-16980A Elevated indications exist on at least one of the following effluent monitors AND no effluent monitors are in alarm AND completed dose assessment results (automated or manual) are not available: Check D Under Evaluation RE-12444C, RE-12444D, RE-12444E, RE-12839C, RE-12839D, RE-12839E, RE-16980A Line 6B or 6C is marked and NO effluent monitor is or has been in Check B Within normal alarm OR has exceeded the specified threshold operating limits 6B or 6C is marked and ANY of the following effluent monitors is or has been in alarm OR has exceeded the specified threshold: RE- Check C Above normal 12444C, RE-12444D, RE-12444E, RE-12839C, RE-12839D, RE- operating limits 12839E, RE-16980A FMT readings or Dose assessment results (automated or manual)
Check C Above normal have been completed AND indicate an emergency radiological release is underway operating limits Dose assessment results indicate an emergency radiological Check C Above normal release occurred previously AND is no longer underway operating limits Standard: Candidate marks Block A (Not applicable) since no release is occurring.
Comment:
10
8.0. Line 8: Select the appropriate box for EVENT PROGNOSIS using the following guidance:
Mark box A Improving if mitigation efforts appear successful, progressing toward termination.
Mark box B Stable if escalation to a higher classification is unlikely based on current conditions.
Mark box C Degrading if escalation to a higher emergency classification or PAR change is likely.
Standard: Candidate marks Block B (Stable) since conditions are not degrading.
Comment:
9.0. Line 9: Enter the 15-minute averaged Wind Direction, Wind Speed, and Precipitation values, and check the appropriate Stability Class from NMP-EP-110 Checklist 1.
Standard: Candidate records the Met Tower Data provided in the Initial Conditions. Wind direction is from 20 degrees, wind speed is 4.5 mph, stability class is D, and there is no precipitation.
Comment:
- 10.0. Line 10: Enter the time and date (mm/dd/yy) when the current emergency classification was declared or terminated.
Standard: Candidate marks Block A (DECLARATION) and enters the time and date of the declaration from Line 5 of NMP-EP-110, Checklist 1.
Comment:
11
11.0. Line 11: Select the affected unit or ALL block if both units are affected by the EAL indicated in Line 4. For events involving equipment that is common to both units, ALL should be selected.
Standard: Candidate marks Block 1 for Unit 1.
Comment:
12.0. Line 12: Unit Status:
12.1. Enter the % power.
12.2. Enter the time (HH:MM) and date of the shutdown if applicable.
Standard: Candidate marks Block A (U1), enters 0% power, and enters shutdown time (20 minutes ago) and date. NOTE: The unaffected units status is not required for the initial notification.
Comment:
13.0. Line 13: Record any current information related to the emergency such as significant events which have occurred, significant equipment which is out of service or malfunctioning, events occurring which may impact offsite resources.
Standard: Candidate may provide remarks about the emergency, but none is required.
Comment:
14.0. IF INITIAL was checked on Line 2 THEN proceed to Line 17, OTHERWISE proceed to Step 15.
Standard: Candidate proceeds to Line 17 (Step 18.0) and leaves Lines 14, 15, and 16 blank.
Comment:
12
- 18.0. Line 17: Review and Approval 18.1. Enter the name of the individual completing the emergency notification form.
18.2. Enter the name of the ED or EOF Mgr approving the emergency notification form.
18.3. Enter the time (HH:MM) and date (mm/dd/yy) the emergency notification form is approved. The specified format is required to proceed.
Standard: Candidate signs for approval as the Emergency Director and records the current date and time. NOTE: The critical step is completing the form within 15 minutes of the Classification Declaration Time recorded on Line 10.
END TIME CRITICAL FOR EMERGENCY NOTIFICATION FORM:
____________ (same as time recorded on Line 17)
Comment:
Terminating cue: Candidate returns cue sheet and completed forms.
13
KEY - Do NOT Give to Candidates Red highlighted items are critical Emergency Notification Form
- 1. X DRILL B ACTUAL EVENT MESSAGE # ___1___
- 2. X INITIAL B FOLLOW-UP NOTIFICATION: TIME________DATE_____/_____/__ AUTHENTICATION # _______
- 3. SITE: ___Vogtle___________ Confirmation Phone #1-706-826-3562(SIM)_
- 4. EMERGENCY A UNUSUAL EVENT B ALERT X SITE AREA EMERGENCY D GENERAL EMERGENCY CLASSIFICATION:
BASED ON EAL# __FS1________ EAL DESCRIPTION: _Loss or Potential Loss of Any Two Barriers___________________
- 5. PROTECTIVE ACTION RECOMMENDATIONS: X NONE B EVACUATE________________________________________________________________________________________
C SHELTER _________________________________________________________________________________________
D Advise Remainder of EPZ to Monitor Local Radio/TV Stations/Tone Alert Radios for Additional Information and Consider the use of KI (potassium iodide) in accordance with State plans and policy.
E OTHER____________________________________________________________________________________________
- 6. EMERGENCY RELEASE: X None B Is Occurring C Has Occurred
- 7. RELEASE SIGNIFICANCE: X Not applicable B Within normal operating C Above normal operating D Under limits limits evaluation
- 8. EVENT PROGNOSIS: A Improving X Stable C Degrading
- 9. METEOROLOGICAL DATA: Wind Direction from _20___ degrees* Wind Speed _4.5___ mph*
(*May not be available for Initial Notifications)*
Precipitation _None_* Stability Class* A B C X E F G
- 10. X DECLARATION B TERMINATION Time __Line 5 of Checklist 1______ Date __Checklist 1 date_/___/___
- 11. AFFECTED UNIT(S): X 2 All
- 12. UNIT STATUS: X U1 __0__% Power Shutdown at Time __T -20 min__ Date _Today_/__/___
(Unaffected Unit(s) Status Not Required B U2 _____% Power Shutdown at Time ____________ Date ___/_____/____
for Initial Notifications)
- 13. REMARKS:____________None____________________________________________________________________________
EMERGENCY RELEASE DATA NOT REQUIRED IF LINE 6 A IS SELECTED.
- 14. RELEASE CHARACTERIZATION: TYPE: A Elevated B Mixed C Ground UNITS: A Ci B Ci/sec C µCi/sec MAGNITUDE: Noble Gases:__________ Iodines:___________ Particulates:__________ Other: ____________
FORM: A Airborne Start Time __________ Date ___/_____/____Stop Time _________ Date ___/_____/____
B Liquid Start Time __________ Date ___/_____/____Stop Time _________ Date ___/_____/____
- 15. PROJECTION PARAMETERS: Projection period: ________Hours Estimated Release Duration ________Hours Projection performed: Time _________ Date ___/_____/____ Accident Type: ________
Site boundary 2 Miles 5 Miles 10 Miles
- 17. APPROVED BY: __Candidate______ Title __ED___ Time _<T +15 from line 10 Date___/_TODAY__/____
NOTIFIED RECEIVED BY: ___________________________ BY: ___________________________ Time ________Date___/_____/____
(To be completed by receiving organization) 14
Verification of Completion Job Performance Measure No.: V-NRC-JP-NMP-EP-110-HL19 Examinees Name:
Examiners Name:
Date Performed:
Number of Attempts:
Time to Complete:
Question Documentation:
Question: __________________________________________________________________
Response: _________________________________________________________________
Result: Satisfactory / Unsatisfactory Examiners signature and date: _______________________________ ____________
15
THIS IS A TIME CRITICAL JPM Initial Conditions: The Unit 1 seismic monitoring system confirmed a seismic event with an earthquake acceleration of 0.14 g.
Unit 1 is in Mode 3 following a reactor trip and Safety Injection 20 minutes ago due to 275 gpm RCS leakage.
Unit 1 containment pressure relief was in progress, and can NOT be isolated.
1RE-005 and 1RE-006 are both indicating 2.6 E+4 mr/hr.
Wind direction (10 meter, 15 min. avg.) is currently 20º at 4.5 mph.
Stability class is D with no precipitation.
WebEOC is NOT functional.
The ENN Communicator has completed recall and roll call.
Initiating Cue: You are the Emergency Director, and based on the given conditions, complete Checklist 1, Classification Determination, of NMP-EP-110, Emergency Classification Determination and Initial Action, through Step 6 to determine the HIGHEST emergency classification level, AND complete NMP-EP-111-F10, SNC Emergency Notifications Form (ENF), for the declared emergency.
Classify the Unit 1 emergency only. Consider Unit 2 unaffected.