ML17276B832

From kanterella
Jump to navigation Jump to search
Final RO Written Exam 05000424/2017301 and 05000425/2017301 - Delay Release 2 Years
ML17276B832
Person / Time
Site: Vogtle  
Issue date: 10/03/2017
From:
NRC/RGN-II
To:
References
Download: ML17276B832 (78)


See also: IR 05000424/2017301

Text

RO Answer Key

1

D

26

A

51

D

2

B

27

C

52

D

3

A

28

A

53

C

4

A

29

C

54

D

5

D

30

D

55

B

6

D

31

B

56

D

7

B

32

B

57

B

8

A

33

B

58

A

9

B

34

B

59

A

10

C

35

C

60

B

11

A

36

A

61

A

12

D

37

B

62

C

13

A

38

C

63

A

14

B

39

D

64

D

15

A

40

D

65

C

16

B

41

B

66

A

17

B

42

A

67

D

18

C

43

C

68

C

19

B

44

C

69

C

20

A

45

D

70

A

21

B

46

A

71

A

22

C

47

B

72

D

23

D

48

C

73

B

24

D

49

D

74

A

25

C

50

B

75

D

Name: ________________________

ILT-21 RO NRC

Student Test

Start Time: _______

Stop Time: _______

ILT-21 RO NRC

1.

Initial conditions:

- Unit 2 is at 52% reactor power.

- Tavg and Tref are matched.

- AFD is +0.3%.

Current conditions:

- Reactor power is 56% and rising.

- Tavg is 3 °F higher than Tref and rising.

- AFD is +1.0% and rising.

Which one of the following completes the following statement?

An __(1)__ is occurring,

and

per Tech Spec 3.2.3, "Axial Flux Difference (AFD)," the AFD is considered outside

limits when a minimum of __(2)__ OPERABLE Power Range NI channels indicate

outside AFD limits.

__(1)__

__(2)__

inadvertent dilution

1

inadvertent dilution

2

uncontrolled continuous rod withdrawal

1

uncontrolled continuous rod withdrawal

2

A.

B.

C.

D.

Page 1 of 75

ILT-21 RO NRC

2.

Initial condition:

- Unit 1 is at 100% reactor power.

Current condition:

- 1CD1 is de-energized due to a fault.

Which one of the following completes the following statements?

The Rod Control Logic Cabinet's normal power supply __(1)__ available.

The Rod Control Logic Cabinet's alternate power supply is __(2)__.

__(1)__

__(2)__

is

Vital 120 VAC Panel

(1CY1A)

is

Regulated 120 VAC Panel

(1NYS)

is NOT

Vital 120 VAC Panel

(1CY1A)

is NOT

Regulated 120 VAC Panel

(1NYS)

A.

B.

C.

D.

Page 2 of 75

ILT-21 RO NRC

3.

Initial conditions:

- Unit 1 is in Mode 5.

- RCS temperature is 150 °F.

- RCS pressure is 350 psig.

Current conditions:

- Crew initiated an RCS heatup at 60 °F/hour.

- RCS temperature is 152 °F.

- RCS pressure rises to 1000 psig due to an unplanned pressure excursion.

Which one of the following completes the following statements?

Consider each statement separately.

Based on the given conditions, Tech Spec LCO 3.4.3, "RCS Pressure and

Temperature (P/T) Limits," __(1)__ met.

For the given conditions, if Tech Spec LCO 3.4.3 is NOT met, the crew is required to

initiate action to restore the parameter(s) to within limits __(2)__.

REFERENCES PROVIDED

__(1)__

__(2)__

is

immediately

is

in no later than 30 minutes

is NOT

immediately

is NOT

in no later than 30 minutes

A.

B.

C.

D.

Page 3 of 75

ILT-21 RO NRC

4.

Initial condition:

- Unit 2 is at 100% reactor power.

Current conditions:

- The following alarms are received:

- ALB07-A05 REGEN HX LTDN HI TEMP

- ALB07-D03 LTDN HX OUT HI TEMP

- ALB08-E06 RCP SEAL WATER INJ FILTER HI DELTA P

Which one of the following completes the following statement?

Based on the current conditions, __(1)__ has failed closed,

and

the identified failure is the result of a __(2)__.

__(1)__

__(2)__

2HV-182, Seal Flow Control

controller malfunction

2HV-182, Seal Flow Control

loss of instrument air

2FV-121, Charging Flow Control

controller malfunction

2FV-121, Charging Flow Control

loss of instrument air

A.

B.

C.

D.

Page 4 of 75

ILT-21 RO NRC

5.

Initial conditions:

- Unit 2 is at 4% reactor power following an outage.

- 12004-C, "Power Operation (Mode 1)," is in progress.

Current condition:

- RCP #2 trips.

Which one of the following completes the following statement?

Following the RCP trip, as RCP speed lowers, the DNBR will __(1)__,

and

based on the given conditions, per 18005-C, "Partial Loss of Flow," the crew is required

to __(2)__.

__(1)__

__(2)__

rise

immediately trip the reactor

rise

initiate a reactor shutdown per 12004-C

lower

immediately trip the reactor

lower

initiate a reactor shutdown per 12004-C

A.

B.

C.

D.

Page 5 of 75

ILT-21 RO NRC

6.

Given the following:

- Unit 1 is performing 13701-1, "Boric Acid System," to startup the system.

- The crew is at the step to "Verify heat tracing for the Boric Acid System is

available as required."

Which one of the following completes the following statement?

The Heat Trace System is designed to __(1)__,

and

Heat Trace System panel alarms __(2)__ be acknowledged by the operator on the

QMCB 'A' panel.

__(1)__

__(2)__

provide freeze protection

will

provide freeze protection

will NOT

maintain boric acid in solution

will

maintain boric acid in solution

will NOT

A.

B.

C.

D.

Page 6 of 75

ILT-21 RO NRC

7.

Initial conditions:

- Unit 1 is in Mode 6.

- RCS level is at 192 feet and stable.

- Both RHR pumps are running.

- Letdown is aligned to RHR Train 'A'.

- RHR Train 'A' is in the following configuration:

1HIC-606A, RHR Heat Exchanger Outlet, is at 0% demand.

1FIC-618A, RHR Heat Exchanger Bypass, is in manual with 75% demand.

- RHR Train 'B' is in the following configuration:

1HIC-607A, RHR Heat Exchanger Outlet, is at 50% demand.

1FIC-619A, RHR Heat Exchanger Bypass, is in manual with 25% demand.

Current conditions:

- RHR pump 'A' trips.

- No operator action has been taken.

Which one of the following completes the following statement?

Based on the given conditions, RCS level will __(1)__,

and

RCS temperature will __(2)__.

__(1)__

__(2)__

rise

rise

rise

remain the same

remain the same

rise

remain the same

remain the same

A.

B.

C.

D.

Page 7 of 75

ILT-21 RO NRC

8.

Initial conditions:

- Unit 1 is in Mode 5 with solid plant conditions.

- Pressurizer bubble is being established.

Current conditions:

- A transient results in an RHR pressure excursion.

- ALB12-E02 PRZR REL TANK HI PRESS is received.

- ALB12-E03 PRZR REL TANK HI TEMP is received.

Which one of the following completes the following statement?

The RHR pump __(1)__ relief valve lifting caused the PRT high pressure condition,

and

per 13004-1, "Pressurizer Relief Tank Operation," PRT cooldown using spray and drain

to lower PRT temperature is expected to take approximately __(2)__ hour(s).

__(1)__

__(2)__

suction

1

suction

8

discharge

1

discharge

8

A.

B.

C.

D.

Page 8 of 75

ILT-21 RO NRC

9.

Initial conditions:

- Unit 1 reactor trip and SI occurred due to a large break LOCA.

- RWST SI TEST LIGHT 'A' white light is lit on the QMCB 'A' panel.

- RWST SI TEST LIGHT 'B' white light is NOT lit on the QMCB 'A' panel.

Current condition:

- RWST level is 28% on all channels and slowly lowering.

Which one of the following completes the following statement?

1HV-8811A, Containment Sump to RHR Pump 'A' Suction, will indicate __(1)__ on the

QMCB,

and

1HV-8811B, Containment Sump to RHR Pump 'B' Suction, will indicate __(2)__ on the

QMCB.

__(1)__

__(2)__

open

open

open

closed

closed

open

closed

closed

A.

B.

C.

D.

Page 9 of 75

ILT-21 RO NRC

10.

Given the following:

- Unit 1 is in Mode 4.

- RHR Train 'A' is aligned for shutdown cooling.

Which one of the following completes the following statement?

Per 13715A-1, "Component Cooling Water System Train 'A'," for RCS temperature

control, CCW flow __(1)__ allowed to be throttled to the RHR Train 'A' heat exchanger,

and

when RHR system temperature first lowers to less than __(2)__ °F, CCW flow is NO

longer required to be supplied to the RHR pump seal coolers.

__(1)__

__(2)__

is

150

is

195

is NOT

150

is NOT

195

A.

B.

C.

D.

Page 10 of 75

ILT-21 RO NRC

11.

Initial condition:

- Unit 2 is at 100% reactor power.

Current conditions:

- An inadvertent SI occurs.

- ALB12-E02 PRZR REL TANK HI PRESS is received.

Which one of the following completes the following statement?

The PRT high pressure condition was caused by __(1)__ relief valve lifting,

and

with no operator action, 2PI-469, PRT Pressure, on the QMCB will reach a maximum

of __(2)__ psig before the rupture disk fails.

__(1)__

__(2)__

2PSV-8121, RCP Seal Return

100

2PSV-8121, RCP Seal Return

115

2PSV-8120, VCT Overpressure

100

2PSV-8120, VCT Overpressure

115

A.

B.

C.

D.

Page 11 of 75

ILT-21 RO NRC

12.

Initial condition:

- Unit 1 is at 100% reactor power.

Current conditions:

- PRT pressure is 5 psig.

- 1PSV-8010A, Pressurizer Safety Valve 'A', fails 20% open.

- The OATC is monitoring 1TI-466, Pressurizer Safety Valve 'A'.

Which one of the following completes the following statement?

1TI-466, Pressurizer Safety Valve 'A', will initially indicate approximately __(1)__ °F,

and

as the safety valve continues to lift, 1TI-466 temperature indication __(2)__ increase

continuously until pressurizer temperature is reached.

__(1)__

__(2)__

212

will

212

will NOT

228

will

228

will NOT

A.

B.

C.

D.

Page 12 of 75

ILT-21 RO NRC

13.

Initial conditions:

- Unit 1 is at 100% reactor power.

- CCW pumps #1 and #3 are running.

- CCW pump #5 is tagged out.

Current conditions:

- ALB02-A05 CCW TRAIN A SURGE TK LO-LO LVL is received.

- CCW pump #3 trips.

- CCW pump #1 is running.

- The following alarms are received:

- ALB02-A06 CCW TRAIN A LO HDR PRESS

- ALB02-B06 CCW TRAIN A LO FLOW

- ALB02-D06 CCW TRAIN A RHR HX LO FLOW

- ALB02-E05 CCW TRAIN A RHR PMP SEAL LO FLOW

- 1FI-1876, CCW Train 'A' Supply Header Flow, indicates 4500 gpm.

Which one of the following completes the following statement?

A single level transmitter failing low on CCW Train 'A' surge tank __(1)__ CCW

pump #3 to trip,

and

the indicated flow on 1FI-1876 __(2)__ consistent with the given conditions.

__(1)__

__(2)__

caused

is

caused

is NOT

did NOT cause

is

did NOT cause

is NOT

A.

B.

C.

D.

Page 13 of 75

ILT-21 RO NRC

14.

Initial conditions:

- Unit 2 reactor tripped due to a small break LOCA.

- 19221-2, "Response to Inadequate Core Cooling," was entered.

Current condition:

- The crew is depressurizing all intact SGs to 120 psig.

Which one of the following completes the following statement?

The depressurization of all intact SGs is stopped when SG pressures reach 120 psig to

prevent ____________.

excessive cooldown of the SG U-tubes

injection of accumulator nitrogen into the RCS

a pressurized thermal shock condition of the reactor vessel

voiding in the reactor vessel head and loss of pressurizer level

A.

B.

C.

D.

Page 14 of 75

ILT-21 RO NRC

15.

Which one of the following completes the following statement?

Unit 1 Pressurizer Code Safety Valve position indications are available on __(1)__,

and

this display indication is powered from __(2)__.

__(1)__

__(2)__

PSMS 'A'

1AY1A

PSMS 'A'

1NYJ

QMCB, 'C' panel

1AY1A

QMCB, 'C' panel

1NYJ

A.

B.

C.

D.

Page 15 of 75

ILT-21 RO NRC

16.

Initial condition:

- Unit 1 experienced a LOCA.

Current conditions:

- The crew is in 19012-1, "Post-LOCA Cooldown and Depressurization."

- RCP #4 is running.

- Containment pressure is 4.5 psig and stable.

- RCS subcooling is 52 °F.

- CCP 'A' and 'B' are in service.

- SIP 'A' and 'B' are in service.

- The crew is at the following step:

Which one of the following completes the following statements?

Per 19012-1, the operators should stop the first CCP and then the first SIP in __(1)__.

Based on the given conditions, the crew __(2)__ required to stop one CCP.

(1) alternate ECCS Trains

(2) is

(1) alternate ECCS Trains

(2) is NOT

(1) the same ECCS Train

(2) is

(1) the same ECCS Train

(2) is NOT

A.

B.

C.

D.

Page 16 of 75

ILT-21 RO NRC

17.

Initial conditions:

- Unit 1 is at 8% reactor power.

- Pressurizer level control is selected to CH 459 / 460.

Current conditions:

- 1LT-459, Pressurizer Level, fails downscale low.

- No operator action has been taken.

Which one of the following completes the following statement?

Seal injection flow to the RCPs will __(1)__,

and

an automatic reactor trip __(2)__ occur on pressurizer level.

__(1)__

__(2)__

rise

will

rise

will NOT

lower

will

lower

will NOT

A.

B.

C.

D.

Page 17 of 75

ILT-21 RO NRC

18.

Initial condition:

- Unit 2 is at 70% reactor power.

Current condition:

- An inadvertent dilution occurs.

Which one of the following completes the following statement?

Based on the given conditions, the OT delta T reactor trip setpoint will __(1)__,

and

the OP delta T reactor trip setpoint will __(2)__.

__(1)__

__(2)__

rise

lower

rise

not change

lower

lower

lower

not change

A.

B.

C.

D.

Page 18 of 75

ILT-21 RO NRC

19.

Initial condition:

- Unit 1 is at 100% reactor power.

Current conditions:

- The bistable(s) for 1PT-934, Containment Pressure Channel IV, are

de-energized.

- No Tech Spec actions have been taken.

Which one of the following completes the following statement?

The minimum number of additional channels required to initiate an actuation signal

on High-1 is __(1)__,

and

the minimum number of additional channels required to initiate an actuation signal

on High-3 is __(2)__.

__(1)__

__(2)__

1

1

1

2

2

1

2

2

A.

B.

C.

D.

Page 19 of 75

ILT-21 RO NRC

20.

Given the following:

- Unit 1 is preparing for a reactor startup per 12003-C, "Reactor Startup (Mode 3 to

Mode 2)."

Which one of the following completes the following statements?

When the OATC momentarily places 1HS-40038, Rod Control Startup Switch, to

START UP, all control rod demand step counters __(1)__ reset to zero.

Control rod demand step counter indications __(2)__ available on the IPC.

__(1)__

__(2)__

will

are

will

are NOT

will NOT

are

will NOT

are NOT

A.

B.

C.

D.

Page 20 of 75

ILT-21 RO NRC

21.

Initial conditions:

- Unit 2 reactor tripped.

- 19001-2, "Reactor Trip Response," is entered.

- Natural circulation verification is in progress.

Current condition:

- Two CETCs fail low.

Which one of the following completes the following statement?

Tech Spec LCO 3.3.3, "Post Accident Monitoring (PAM) Instrumentation," requires a

minimum of __(1)__ OPERABLE CETC channels per quadrant,

and

based on the current conditions, the failed CETCs __(2)__ be included in the

calculated subcooling margin displayed on the IPC.

__(1)__

__(2)__

2

will

2

will NOT

4

will

4

will NOT

A.

B.

C.

D.

Page 21 of 75

ILT-21 RO NRC

22.

Initial conditions:

- Unit 1 is at 100% reactor power.

- 18007-C, "Chemical and Volume Control System Malfunction," is in progress due

to a controller malfunction.

Current conditions:

- The controller has been repaired.

- Normal charging is being restored to service per 13006-1, "Chemical and Volume

Control System."

- Pressurizer level has been stable within 1% of program for 3 minutes.

- OATC is ready to return pressurizer level control to automatic.

Which one of the following completes the following statement?

Pressurizer level is maintained stable for at least 3 minutes prior to placing pressurizer

level control in automatic to ensure the large error signal in __(1)__ has time to decay,

and

per NMP-OS-007-001, "Conduct of Operations Standards and Expectations," Shift

Manager permission __(2)__ required prior to returning the level control system to

automatic.

__(1)__

__(2)__

1FIC-121, Charging Flow Control

is

1FIC-121, Charging Flow Control

is NOT

1LIC-459, Pressurizer Level Control

is

1LIC-459, Pressurizer Level Control

is NOT

A.

B.

C.

D.

Page 22 of 75

ILT-21 RO NRC

23.

Initial conditions:

- Unit 1 is in Mode 4.

- A loss of all NSCW occurs.

- RCS and containment temperatures are rising.

Current conditions:

- The crew determines that NSCW Train 'A' can be re-started in single pump

operation.

- 13150A-1, "Train 'A' Nuclear Service Cooling Water System," is in progress.

Which one of the following is (are) the NSCW Train 'A' load(s) that must be isolated

prior to the re-start of one NSCW pump to ensure adequate cooling is provided to

required NSCW loads?

Component Cooling Water Heat Exchanger

Diesel Generator Jacket Water Heat Exchanger

Control Building Engineered Safety Features Chiller

Containment Auxiliary Cooler and Reactor Cavity Cooler

A.

B.

C.

D.

Page 23 of 75

ILT-21 RO NRC

24.

Initial conditions:

- Unit 2 is in Mode 5.

- RHR pump 'A' is in service for shutdown cooling.

Current conditions:

- RCS level is 192 feet and slowly lowering due to a leak.

- RCS temperature is 190 °F.

- 18019-C, "Loss of Residual Heat Removal," is in progress.

Which one of the following completes the following statements?

Based on the current conditions and per 18019-C, the operating crew __(1)__ required

to stop RHR pump 'A'.

Per 18019-C, if no pump is available, the preferred gravity drain path to restore

inventory is through the __(2)__ pumps to the RCS Cold Legs.

__(1)__

__(2)__

is

SI

is

RHR

is NOT

SI

is NOT

RHR

A.

B.

C.

D.

Page 24 of 75

ILT-21 RO NRC

25.

Given the following:

- Unit 1 experienced a large break LOCA.

- 19010-1, "Loss of Reactor or Secondary Coolant," is in progress.

- Containment Spray has been aligned to the recirculation mode.

Which one of the following completes the following statement?

Control of containment fluid pH is accomplished by __(1)__,

and

per 19010-1, Containment Spray is required to operate in the recirculation mode for a

minimum of __(2)__ hours.

__(1)__

__(2)__

batch chemical addition

1.5

batch chemical addition

2

chemical storage baskets

1.5

chemical storage baskets

2

A.

B.

C.

D.

Page 25 of 75

ILT-21 RO NRC

26.

Given the following:

- Unit 2 is at 100% reactor power.

- 2PIC-455A, Pressurizer Pressure Master Controller, output demand fails low.

- 18000-C, "Pressurizer Spray, Safety, or Relief Valve Malfunction," is entered.

Which one of the following completes the following statement?

In response to the controller failure, the pressurizer backup heaters __(1)__ energize,

and

per 18000-C, the OATC __(2)__ allowed to operate 2PIC-455B and 2PIC-455C,

Pressurizer Spray Controllers, in manual to control pressurizer pressure.

__(1)__

__(2)__

will

is

will

is NOT

will NOT

is

will NOT

is NOT

A.

B.

C.

D.

Page 26 of 75

ILT-21 RO NRC

27.

Given the following:

- Unit 1 experiences a large break LOCA.

- Containment pressure is 26 psig.

- Containment Spray is operating.

Which one of the following completes the following statement?

One purpose of the Containment Spray system is to remove __(1)__ from the

containment atmosphere,

and

per 19013-1, "Transfer to Cold Leg Recirculation," the operating crew __(2)__ required

to reset the Containment Spray actuation signal prior to aligning the CS pumps for

recirculation.

__(1)__

__(2)__

noble gases

is

noble gases

is NOT

gaseous iodine

is

gaseous iodine

is NOT

A.

B.

C.

D.

Page 27 of 75

ILT-21 RO NRC

28.

Initial conditions:

- Unit 1 is at 100% reactor power.

- Pressurizer level control is selected to CH 461 / 460.

Current conditions:

- 1LT-461, Pressurizer Level, fails as-is.

- Reactor power is being lowered to 30%.

Which one of the following completes the following statement?

As reactor power lowers, with no additional operator action, ALB11-C01 PRZR

CONTROL HI LEVEL DEV AND HEATERS ON __(1)__ alarm,

and

CVCS letdown __(2)__ isolate.

__(1)__

__(2)__

will

will

will

will NOT

will NOT

will

will NOT

will NOT

A.

B.

C.

D.

Page 28 of 75

ILT-21 RO NRC

29.

Given the following:

- Unit 1 is at 100% reactor power.

- Containment pressure is +0.8 psig and stable.

- Containment pressure relief is being performed per 13125-1, "Containment

Purge System."

Which one of the following completes the following statement?

Based on the given conditions and per 13125-1, when the crew begins the pressure

relief, the Mini-Purge Exhaust Fan __(1)__ required to be started,

and

containment pressure __(2)__ be monitored on the QHVC panel.

__(1)__

__(2)__

is

can

is

can NOT

is NOT

can

is NOT

can NOT

A.

B.

C.

D.

Page 29 of 75

ILT-21 RO NRC

30.

Initial condition:

- Unit 1 is at 45% reactor power.

Current conditions:

- ATWT is in progress.

- The Main Turbine will NOT trip from the Control Room.

- The Reactor Trip Breakers can NOT be opened locally.

Which one of the following completes the following statement?

Per 19211-1, "Response to Nuclear Power Generation / ATWT," the Control Rod Drive

MG Set __(1)__ breakers will be opened,

and

ALB09-E02 TURBINE TRIP DUE TO REACTOR TRIP __(2)__ be received when the

MG Set breakers are locally opened.

__(1)__

__(2)__

input

will

input

will NOT

output

will

output

will NOT

A.

B.

C.

D.

Page 30 of 75

ILT-21 RO NRC

31.

Procedure titles as follows:

- 19231-1, "Response to Loss of Secondary Heat Sink"

- 19235-1, "Response to Steam Generator Low Level"

Given the following:

- Unit 1 reactor tripped.

- 19200-1, "Critical Safety Function Status Tree," is initiated by the OATC.

- Containment pressure is 0.4 psig.

- SG pressures are 1000 psig in each SG.

- Total AFW flow has been throttled to 530 gpm.

- SG NR levels are as follows:

- SG #1 is 8%

- SG #2 is 9%

- SG #3 is 7%

- SG #4 is 10%

Which one of the following completes the following statement?

To ensure the CSFSTs are indicating correctly for the given plant conditions, the OATC

is required to verify the IPC indicates Mode __(1)__,

and

the Heat Sink status tree indicates conditions are met for a transition to __(2)__.

__(1)__

__(2)__

0

19231-1

0

19235-1

3

19231-1

3

19235-1

A.

B.

C.

D.

Page 31 of 75

ILT-21 RO NRC

32.

Initial conditions:

- Unit 1 tripped due to a SGTR.

- 19030-1, "Steam Generator Tube Rupture," is in progress.

- All RCPs are stopped.

- RCS subcooling is 29 °F.

- The crew has commenced the RCS cooldown.

Current condition:

- IPC indicates a RED path on Integrity and is directing a transition to 19241-1,

"Response to Imminent Pressurized Thermal Shock Condition."

Which one of the following completes the following statement?

Per 19030-1, Attachment 2, "Verification of Natural Circulation," the minimum required

subcooling to support natural circulation flow __(1)__ currently available,

and

based on the given conditions, the crew __(2)__ required to immediately transition to

19241-1.

__(1)__

__(2)__

is

is

is

is NOT

is NOT

is

is NOT

is NOT

A.

B.

C.

D.

Page 32 of 75

ILT-21 RO NRC

33.

Given the following:

- Unit 2 is at 100% reactor power.

- 18009-C, "Steam Generator Tube Leak," is in progress.

- Total charging flow is 93 gpm.

- Letdown flow is 75 gpm.

- Total RCP seal leak-off flow is 12 gpm.

- 2RE-810, SJAE Rad Monitor, indicates a leak rate of change of 25 gpd/hour after

30 minutes of trend data.

Which one of the following completes the following statement?

Per 18009-C, the crew __(1)__ required to initiate a plant shutdown to Mode 3 using

18013-C, "Rapid Power Reduction,"

and

Tech Spec LCO 3.4.13, "RCS Operational Leakage," __(2)__ met.

__(1)__

__(2)__

is

is

is

is NOT

is NOT

is

is NOT

is NOT

A.

B.

C.

D.

Page 33 of 75

ILT-21 RO NRC

34.

Initial conditions:

- Unit 1 is at 60% reactor power and stable.

- MFP 'B' startup is in progress and has been idling at 1200 rpm for 15 minutes.

Current conditions:

- ALB15-D03 MFPT A TRIPPED is received.

- Feed flow indications indicate 0 MPPH on all SGs.

- MFP 'B' continues to idle in manual.

- All SG NR levels are 60% and lowering.

Which one of the following completes the following statement?

Per 18016-C, "Condensate and Feedwater Malfunction," the first action the crew is

required to perform is to __(1)__,

and

the MDAFW pumps will first receive a start signal on __(2)__.

__(1)__

__(2)__

trip the reactor

the trip of MFP 'A'

trip the reactor

SG low level

raise MFP 'B' speed

the trip of MFP 'A'

raise MFP 'B' speed

SG low level

A.

B.

C.

D.

Page 34 of 75

ILT-21 RO NRC

35.

Initial conditions:

- Unit 2 reactor tripped due to a loss of off-site power.

- 2AA02 and 2BA03 are de-energized.

- 19100-2, "Loss of All AC Power," is in progress.

- Instrument air header pressure is rapidly lowering.

Current condition:

- The crew is checking the status of CVCS valves.

Which one of the following completes the following statement?

With no operator action following the loss of instrument air, 2LV-459 and 2LV-460,

Letdown Isolations, will be __(1)__,

and

2HV-8105 and 2HV-8106, Charging to RCS Isolations, will be __(2)__.

__(1)__

__(2)__

open

open

open

closed

closed

open

closed

closed

A.

B.

C.

D.

Page 35 of 75

ILT-21 RO NRC

36.

Initial conditions:

- Unit 1 is at 100% reactor power.

- SJAE #1 is in standby.

- SJAE #2 is in service.

Current condition:

- SJAE #1 loop seal drain isolation valve fails open.

Which one of the following completes the following statement?

With no operator action, reactor power __(1)__ lower,

and

entry into 18040-C, "Partial Loss of Condenser Vacuum," __(2)__ required.

__(1)__

__(2)__

will

is

will

is NOT

will NOT

is

will NOT

is NOT

A.

B.

C.

D.

Page 36 of 75

ILT-21 RO NRC

37.

Initial conditions:

- Unit 1 is at 35% reactor power.

- MFP 'A' is running.

Current conditions:

- Both RATs de-energize due to a switchyard fault.

- Unit 1 reactor is tripped.

- 19001-1, "Reactor Trip Response," is in progress.

- Crew is at Step 9 to "Check SG levels."

- SG NR levels are 7% in each SG.

- MDAFW flow is throttled to 135 gpm to each SG.

Which one of the following completes the following statement?

Based on the current conditions, an adequate heat sink __(1)__ exist,

and

when the UO trips MFP 'A', the MDAFW pump discharge valves will __(2)__.

__(1)__

__(2)__

does

re-open fully

does

remain throttled

does NOT

re-open fully

does NOT

remain throttled

A.

B.

C.

D.

Page 37 of 75

ILT-21 RO NRC

38.

Initial conditions:

- Unit 2 is at 100% reactor power.

- A loss of off-site power occurs.

Current conditions:

- DG2A starts and re-energizes its associated bus.

- DG2B will NOT start.

- 2BD1 bus voltage is 103 VDC.

Which one of the following completes the following statements?

Based on the given conditions, per 18031-2, "Loss of Class 1E Electrical Systems," the

minimum required action(s) to take for 2BD1 is (are) to __(1)__.

The reason for removing 2BD1 from service is to prevent __(2)__.

(1) open its associated battery breaker

(2) cell reversal

(1) open its associated battery breaker

(2) an excessive buildup of hydrogen

(1) shutdown its associated inverter and then open its battery breaker

(2) cell reversal

(1) shutdown its associated inverter and then open its battery breaker

(2) an excessive buildup of hydrogen

A.

B.

C.

D.

Page 38 of 75

ILT-21 RO NRC

39.

Initial conditions:

- Unit 1 is at 100% reactor power.

- DG1B is running for a monthly surveillance.

Current conditions:

- 1BD1 de-energizes due to a fault.

- 18034-1, "Loss of Class 1E 125 VDC Power," is in progress.

Which one of the following completes the following statement?

Depressing the DG1B Emergency Stop pushbuttons on the QEAB __(1)__ stop DG1B,

and

the DG1B output breaker is required to be opened using the local breaker __(2)__.

__(1)__

__(2)__

will

handswitch

will

TRIP pushbutton

will NOT

handswitch

will NOT

TRIP pushbutton

A.

B.

C.

D.

Page 39 of 75

ILT-21 RO NRC

40.

Initial condition:

- Unit 1 is at 100% reactor power.

Current conditions:

- A 200 MWe load rejection occurs.

- Main turbine load has stabilized.

Which one of the following completes the following statement?

Based on the current conditions, the final MFRV positions will be more __(1)__ than

prior to the transient,

and

the final MFP speeds will be __(2)__ than prior to the transient.

__(1)__

__(2)__

open

higher

open

lower

closed

higher

closed

lower

A.

B.

C.

D.

Page 40 of 75

ILT-21 RO NRC

41.

Initial condition:

- Unit 1 Waste Gas Decay Tank release is in progress.

Current conditions:

- A diaphragm valve fails in the Waste Gas System.

- ARE-0014, Waste Gas Processing Effluent Monitor, is in intermediate alarm.

- No operator action has been taken.

Which one of the following completes the following statement?

ARV-0014, Plant Vent Radwaste Gas, isolation valve is __(1)__,

and

the position of ARV-0014 will be verified by the operators __(2)__.

__(1)__

__(2)__

open

on the IPC in the Control Room

open

locally on the Gaseous Waste Panel

closed

on the IPC in the Control Room

closed

locally on the Gaseous Waste Panel

A.

B.

C.

D.

Page 41 of 75

ILT-21 RO NRC

42.

Initial conditions:

- Unit 1 is in Mode 3.

- MDAFW pump 'A' is running.

- MDAFW pump 'B' and the TDAFW pump are in standby.

Current condition:

- Maintenance requests to simultaneously open both 1-1302-U4-055 and

1-1302-U4-056, MDAFW Pump Cross-Connect Valves, for a PM.

Per 13610-1, "Auxiliary Feedwater System," which one of the following completes the

following statements?

For the given conditions, opening both 1-1302-U4-055 and 1-1302-U4-056 at the same

time __(1)__ violate Tech Spec LCO 3.7.5, "Auxiliary Feedwater (AFW) System."

To prevent pump runout, MDAFW pump 'A' flow rate is required to be limited to a

maximum of __(2)__ gpm.

__(1)__

__(2)__

will

600

will

1260

will NOT

600

will NOT

1260

A.

B.

C.

D.

Page 42 of 75

ILT-21 RO NRC

43.

Initial conditions:

- Unit 1 experienced a loss of heat sink.

- TDAFW pump governor developed a hydraulic oil leak.

- TDAFW pump tripped on overspeed.

- 1HS-15111, TDAFW Trip and Throttle Valve, green and amber lights are lit.

Current condition:

- OAO is dispatched to reset the TDAFW pump mechanical overspeed trip.

Which one of the following completes the following statement?

The amber light on 1HS-15111 will extinguish when __(1)__,

and

with the failed governor valve, the TDAFW pump __(2)__ be operated locally.

(1) 1HS-5106A, TDAFW Steam Supply, is taken to the close position

(2) can

(1) 1HS-5106A, TDAFW Steam Supply, is taken to the close position

(2) can NOT

(1) the mechanical trip linkage is manually reset

(2) can

(1) the mechanical trip linkage is manually reset

(2) can NOT

A.

B.

C.

D.

Page 43 of 75

ILT-21 RO NRC

44.

Initial conditions:

- Unit 1 is at 100% reactor power.

- DG1A is paralleled with RAT '1A' for surveillance testing.

Current condition:

- Lockout relay 186C actuates due to reverse power on DG1A.

Which one of the following completes the following statement?

The DG1A engine __(1)__ automatically shutdown,

and

1AA02-19, DG1A Output Breaker, __(2)__ automatically trip open.

__(1)__

__(2)__

will

will

will

will NOT

will NOT

will

will NOT

will NOT

A.

B.

C.

D.

Page 44 of 75

ILT-21 RO NRC

45.

Initial conditions:

- Unit 2 is in Mode 3.

- CCP 'B' is running.

Current condition:

- 2BD1 is de-energized due to a fault.

Which one of the following completes the following statement?

If an overcurrent relay actuates in the CCP 'B' pump breaker, the breaker __(1)__

automatically trip open,

and

QMCB handswitch indication of the CCP 'B' breaker position __(2)__ be available.

__(1)__

__(2)__

will

will

will

will NOT

will NOT

will

will NOT

will NOT

A.

B.

C.

D.

Page 45 of 75

ILT-21 RO NRC

46.

Initial conditions:

- Unit 1 is at 100% reactor power.

- DG1A is tagged out.

- A loss of off-site power occurs due to a switchyard fault.

- The following alarms are received:

ALB35-F02 DG1B LOW PRESS STARTING AIR

ALB35-F05 DG1B FAILED TO START

Current conditions:

- 19100-1, "Loss of All AC Power," directs a DG1B start.

- DG1B starting air receiver pressures each indicate 142 psig.

Which one of the following completes the following statements?

Based on the given conditions, the operator will perform a(n) __(1)__ start of DG1B.

After starting and during the subsequent DG1B shutdown, depressing 1HS-4583,

RESET FROM LOCA/LOSP pushbutton, __(2)__ restore the non-emergency trips for

DG1B.

__(1)__

__(2)__

normal

will

normal

will NOT

emergency

will

emergency

will NOT

A.

B.

C.

D.

Page 46 of 75

ILT-21 RO NRC

47.

Initial conditions:

- Unit 2 is at 100% reactor power.

- Train 'B' sequencer simulated software test (UV) is in progress per 13540B-2,

"Safety Feature Sequencer System - Train 'B'."

Current condition:

- The normal incoming breaker to 2BA03 trips open.

Which one of the following completes the following statement?

With the test in progress, the Train 'B' sequencer __(1)__ detect the UV condition on

2BA03,

and

manual action to take the Train 'B' sequencer out of the Test Mode __(2)__ required

for DG2B to automatically start.

__(1)__

__(2)__

will

is

will

is NOT

will NOT

is

will NOT

is NOT

A.

B.

C.

D.

Page 47 of 75

ILT-21 RO NRC

48.

Given the following:

- Unit 1 was at 100% reactor power.

- A fire occurred in the QHVC panel requiring Control Room evacuation per

18038-1, "Operation from Remote Shut Down Panels."

Which one of the following completes the following statement?

After tripping the reactor per 18038-1, entry into 19000-1, "Reactor Trip or Safety

Injection," __(1)__ required,

and

18038-1, Attachment 9, "Control Switch Required Positions," __(2)__ be performed for

both SDP 'A' and SDP 'B'.

__(1)__

__(2)__

is

will

is

will NOT

is NOT

will

is NOT

will NOT

A.

B.

C.

D.

Page 48 of 75

ILT-21 RO NRC

49.

Initial condition:

- Waste Monitor Tank (WMT) #9 release is in progress.

Current conditions:

- 1RX-0018, Liquid Effluent Monitor, DPM TROUBLE light is lit.

- 1RE-0018, Liquid Effluent Monitor, fails downscale low.

Which one of the following completes the following statement?

The WMT #9 liquid release __(1)__ automatically isolate,

and

per the ODCM, to perform any additional WMT releases, 1RE-0018 __(2)__ required

to be returned to service.

__(1)__

__(2)__

will

is

will

is NOT

will NOT

is

will NOT

is NOT

A.

B.

C.

D.

Page 49 of 75

ILT-21 RO NRC

50.

Initial conditions:

- The Control Room has been evacuated due to toxic gas.

- 18038-1, "Operation from Remote Shut Down Panels," is in progress.

- All SDP 'A' handswitches have been taken to LOCAL.

Current condition:

- An automatic SI occurs.

Which one of the following completes the following statement?

DG1A __(1)__ automatically start,

and

SI pump 'A' __(2)__ automatically start.

__(1)__

__(2)__

will

will

will

will NOT

will NOT

will

will NOT

will NOT

A.

B.

C.

D.

Page 50 of 75

ILT-21 RO NRC

51.

Valve and radiation monitor names as follows:

- 1RE-0019, SG Sample Liquid

- 1RE-0021, SG Blowdown Liquid

- 1FV-1150, Blowdown Inlet Isolation Valve

- 1HV-7600, Blowdown Recycle Isolation Valve

Initial conditions:

- Unit 1 is at 100% reactor power.

- SGBD is in service.

Current conditions:

- One SGBD radiation detector fails high.

- SGBD automatically isolates.

Which one of the following completes the following statement?

Based on the given conditions, __(1)__ failed high,

and

the detector failure caused __(2)__ to automatically close.

__(1)__

__(2)__

1RE-0019

1HV-7600

1RE-0019

1FV-1150

1RE-0021

1HV-7600

1RE-0021

1FV-1150

A.

B.

C.

D.

Page 51 of 75

ILT-21 RO NRC

52.

Initial conditions:

- Unit 1 is at 100% reactor power.

- TPCW pump #1 is in service.

- TPCCW pump #1 is in service.

Current condition:

- TPCW pump #1 breaker trips.

Which one of the following completes the following statements?

Over the next 30 minutes, TPCCW temperature __(1)__ expected to rise.

Any temperature changes in TPCCW will directly affect the __(2)__ Coolers.

__(1)__

__(2)__

is

Generator Hydrogen

is

Electrohydraulic Control (EHC)

is NOT

Generator Hydrogen

is NOT

Electrohydraulic Control (EHC)

A.

B.

C.

D.

Page 52 of 75

ILT-21 RO NRC

53.

Initial conditions:

- Unit 1 reactor trip and SI occurred due to a LOCA.

- 19000-1, "Reactor Trip or Safety Injection," is in progress.

Current condition:

- The OATC verified correct SI alignment on the MLBs.

Which one of the following completes the following statement?

On the MLBs, the NSCW supply valves to the Auxiliary Coolers indicate __(1)__,

and

the NSCW supply valves to the Containment Coolers indicate __(2)__.

__(1)__

__(2)__

open

open

open

closed

closed

open

closed

closed

A.

B.

C.

D.

Page 53 of 75

ILT-21 RO NRC

54.

Initial conditions:

- Unit 1 reactor trip and SI occurred due to a LOCA.

- Fuel damage has occurred.

At time 1000:

- 1RE-002, Containment - Low Range, is 500 mr/hour.

- 1RE-003, Containment - Low Range, is 525 mr/hour.

At time 1030:

- 1RE-002, Containment - Low Range, is 760 mr/hour.

- 1RE-003, Containment - Low Range, is 750 mr/hour.

Which one of the following completes the following statement?

The crew first meets entry criteria into 19253-1, "Response to High Containment

Radiation Level," at time __(1)__,

and

per the MAJOR ACTIONS of 19253-1, the operators are required to verify proper

__(2)__ alignment.

__(1)__

__(2)__

1000

CIA

1000

CVI

1030

CIA

1030

CVI

A.

B.

C.

D.

Page 54 of 75

ILT-21 RO NRC

55.

Initial condition:

- Unit 1 is at 100% reactor power.

Current conditions:

- 18017-C, "Abnormal Grid Disturbances / Loss of Grid," Section 'A' for "Degraded

Grid Conditions," is in progress.

- Unit 1 lagging MVARs (positive) are rising due to grid instability.

Which one of the following completes the following statement?

Overexcitation will lead to damage to the main generator __(1)__,

and

in order to reduce the lagging MVARs (positive), the UO is required to adjust main

generator __(2)__.

__(1)__

__(2)__

rotor

frequency

rotor

voltage

stator

frequency

stator

voltage

A.

B.

C.

D.

Page 55 of 75

ILT-21 RO NRC

56.

Initial conditions:

- Unit 1 is at 100% reactor power.

- Air Compressors #1 and #3 are in service.

- Air Compressors #2 and #4 are in AUTO-PTL.

Current conditions:

- ALB01-C06 SERVICE AIR HDR LO PRESS is received.

- 1PI-9377, Service Air Header Pressure, on the QMCB lowered to 92 psig and is

now stable at 105 psig.

Which one of the following completes the following statement?

1PV-9375, Service Air Dryer Inlet Isolation Valve, __(1)__ closed,

and

Air Compressors #2 and #4 automatically started __(2)__ ALB01-C06 was received.

__(1)__

__(2)__

is

after

is

before

is NOT

after

is NOT

before

A.

B.

C.

D.

Page 56 of 75

ILT-21 RO NRC

57.

Initial conditions:

- Unit 1 is at 100% reactor power.

- Air Compressor #4 is in service and aligned to Unit 1.

Current conditions:

- RAT '1A' and RAT '1B' de-energize due to a switchyard fault.

- DG1A and DG1B start and re-energize their associated buses.

- The reactor is NOT tripped.

Which one of the following completes the following statements?

Based on the current conditions, Air Compressor #4 is __(1)__.

When the OATC trips the reactor, Air Compressor #4 will be __(2)__.

__(1)__

__(2)__

energized

energized

energized

de-energized

de-energized

energized

de-energized

de-energized

A.

B.

C.

D.

Page 57 of 75

ILT-21 RO NRC

58.

Initial conditions:

- Unit 2 is in a refueling outage.

- Core reload is in progress.

Current condition:

- The inner emergency airlock door is open and is NOT capable of being closed.

Which one of the following completes the following statement?

Per Tech Spec LCO 3.9.4, "Containment Penetrations," the equipment hatch must be

capable of being closed and held in place with a minimum of __(1)__ bolts,

and

per Tech Spec LCO 3.9.4, core reload __(2)__ allowed to continue.

__(1)__

__(2)__

4

is

4

is NOT

8

is

8

is NOT

A.

B.

C.

D.

Page 58 of 75

ILT-21 RO NRC

59.

Given the following:

- Unit 1 reactor trip and SI occurred due to a large break LOCA.

- Containment pressure is 22 psig.

- Containment hydrogen concentration is 5.1%.

Which one of the following completes the following statement?

The lower flammability limit for hydrogen in containment __(1)__ been exceeded,

and

the preferred method for reducing containment hydrogen concentration is __(2)__ the

containment atmosphere.

__(1)__

__(2)__

has

diluting

has

purging

has NOT

diluting

has NOT

purging

A.

B.

C.

D.

Page 59 of 75

ILT-21 RO NRC

60.

Initial condition:

- Unit 2 is in Mode 6 for a refueling outage.

Current conditions:

- A fuel assembly has been lowered into the wrong core location.

- Source Range counts are unexpectedly rising on NR-45.

Which one of the following completes the following statements?

Consider each statement separately.

Per 93300-C, "Conduct of Refueling Operations," the OATC (Reactor Operator)

__(1)__ have the authority to direct disengagement of fuel assemblies.

Based on the current conditions, if the Fuel Handling Supervisor (FHS) requests

permission to unlatch the assembly just lowered, the FHS __(2)__ be directed to

disengage the fuel assembly at the current location.

__(1)__

__(2)__

does

will

does

will NOT

does NOT

will

does NOT

will NOT

A.

B.

C.

D.

Page 60 of 75

ILT-21 RO NRC

61.

Which one of the following completes the following statement?

Per NMP-AD-006, "Infrequently Performed Tests and Evolutions," the IPTE briefing

__(1)__ required to be conducted by Senior Line Management,

and

an activity that requires an IPTE briefing is __(2)__.

__(1)__

__(2)__

is

reactor vessel head lift

is

CVCS demin resin replacement

is NOT

reactor vessel head lift

is NOT

CVCS demin resin replacement

A.

B.

C.

D.

Page 61 of 75

ILT-21 RO NRC

62.

Which one of the following completes the following statements?

Per Tech Spec SR 3.0.2, for surveillances with periodic frequencies on a "once per..."

basis, a performance interval extension __(1)__ be applied to the first performance.

Per Tech Spec SR 3.0.3, when a surveillance is discovered to have NOT been

performed within its specified frequency, a risk evaluation __(2)__ required to be

performed in order to delay performance of the surveillance greater than 24 hours2.777778e-4 days <br />0.00667 hours <br />3.968254e-5 weeks <br />9.132e-6 months <br />.

__(1)__

__(2)__

can

is

can

is NOT

can NOT

is

can NOT

is NOT

A.

B.

C.

D.

Page 62 of 75

ILT-21 RO NRC

63.

Given the following:

- Systems Operator (SO) will make multiple entries into AB-A-103 during the shift

for support of CVCS valve repairs.

- The SO will use RWP 17-0108 (red RWP).

- The SO's RWP has a dose limit of 50 mrem.

Which one of the following completes the following statement?

The SO __(1)__ required to receive an RP briefing prior to each AB-A-103 entry,

and

per the RCA trip ticket and NMP-HP-008, "Radiation Protection Conduct of

Operations," exiting the RCA before the SO's electronic dosimeter indicates 50 mrem

__(2)__ required.

__(1)__

__(2)__

is

is

is

is NOT

is NOT

is

is NOT

is NOT

A.

B.

C.

D.

Page 63 of 75

ILT-21 RO NRC

64.

Valve names as follows:

- 1HV-2624A, CTB Post-LOCA Purge Exhaust IRC Isolation

- 1-1508-U4-012, Post-LOCA Purge CTB Isolation [Equip Bldg roof (Dog House)]

Given the following:

- Unit 1 reactor trip and SI occurred due to a large break LOCA.

- Post-LOCA hydrogen purge is being placed in service using 13130-1,

"Post-Accident Hydrogen Control."

- Systems Operator (SO) is getting briefed.

Which one of the following completes the following statements?

Per 13130-1, to minimize radiation exposure to the SO, the first valve required to be

opened is __(1)__.

In order to open 1HV-2624A, resetting __(2)__ is required.

__(1)__

__(2)__

1HV-2624A

CIA

1HV-2624A

CVI

1-1508-U4-012

CIA

1-1508-U4-012

CVI

A.

B.

C.

D.

Page 64 of 75

ILT-21 RO NRC

65.

Initial conditions:

- Unit 1 reactor trip and SI occurred due to a SG #2 tube rupture.

- 1PV-3010, SG #2 ARV, is lifting.

Current condition:

- 1RE-12116 and 1RE-12117, Control Room Air Intake, are in high alarm.

Which one of the following completes the following statement?

Per 13301-C, "CBCR Normal HVAC and Emergency Filtration System," the crew is

required to verify the Control Room HVAC is in the __(1)__ Mode of operation,

and

both Train 'A' and Train 'B' ESF Chillers __(2)__ automatically start.

__(1)__

__(2)__

Isolation

will

Isolation

will NOT

Recirculation (Filtration)

will

Recirculation (Filtration)

will NOT

A.

B.

C.

D.

Page 65 of 75

ILT-21 RO NRC

66.

Initial condition:

- Unit 2 reactor trip and SI occurred due to a SGTR.

Current conditions:

- Crew is initiating the Foldout Page of 19000-2, "Reactor Trip or Safety Injection."

- Containment pressure is 1.4 psig and stable.

- All SG NR levels are 10% and slowly rising.

Per 10020-C, "EOP and AOP Rules of Usage," which one of the following completes

the following statements?

Based on the given conditions, the UO __(1)__ allowed to take early operator action to

isolate AFW to the ruptured SG.

Shift Supervisor permission __(2)__ required prior to performing early operator actions.

__(1)__

__(2)__

is

is

is

is NOT

is NOT

is

is NOT

is NOT

A.

B.

C.

D.

Page 66 of 75

ILT-21 RO NRC

67.

Given the following:

- Unit 2 reactor trip and SI occurs.

- The Shift Manager declares an ALERT emergency.

Which one of the following completes the following statement?

Per NMP-EP-111, "Emergency Notifications," the primary communication system used

to notify the NRC of the declaration is the __(1)__,

and

per NMP-EP-111, hourly follow-up notifications to the NRC __(2)__ required.

__(1)__

__(2)__

ENN

are

ENN

are NOT

ENS

are

ENS

are NOT

A.

B.

C.

D.

Page 67 of 75

ILT-21 RO NRC

68.

Given the following:

- Unit 1 control room is being evacuated due to a fire.

- The operating crew is fully staffed.

Which one of the following completes the following statement?

Per 18038-1, "Operation From Remote Shut Down Panels," the Shift Supervisor

__(1)__ dispatched to SDP 'A',

and

the preferred method for establishing communications between all stations is __(2)__.

__(1)__

__(2)__

is

sound powered telephones

remote shutdown channel (red box)

is

bridge phone extension 1624,

codes 123# or 234#

is NOT

sound powered telephones

remote shutdown channel (red box)

is NOT

bridge phone extension 1624,

codes 123# or 234#

A.

B.

C.

D.

Page 68 of 75

ILT-21 RO NRC

69.

Initial conditions:

- Unit 1 reactor trip and SI occurred.

- 19112-1, "LOCA Outside Containment," is in progress.

Current conditions:

- RCS pressure is 807 psig and slowly rising.

- RCS subcooling is 14 °F and slowly rising.

- Containment pressure is 2 psig.

- Pressurizer level is below the indicating range.

Which one of the following completes the following statements?

Per 19112-1, the first system to be isolated from the RCS to attempt leak isolation is

__(1)__.

Based on the current conditions, the leak __(2)__ isolated.

__(1)__

__(2)__

SI

is

SI

is NOT

RHR

is

RHR

is NOT

A.

B.

C.

D.

Page 69 of 75

ILT-21 RO NRC

70.

Initial conditions:

- Unit 1 reactor tripped due to a loss of main feedwater.

- 19231-1, "Response to Loss of Secondary Heat Sink," is in progress.

Current conditions:

- RCS bleed and feed is in progress.

- The crew is re-establishing feedwater using a MFP.

- Containment pressure is 1.5 psig.

- Low Steamline Pressure SI/SLI and Low Pressurizer Pressure SI signals are

blocked.

Which one of the following completes the following statement?

After resetting SI, the crew __(1)__ required to cycle the Reactor Trip Breakers, by

momentarily closing them, in order to reset the FWI,

and

based on the current conditions, if a high steam pressure rate setpoint is exceeded

while depressurizing a SG, an automatic SLI __(2)__ occur.

__(1)__

__(2)__

is

will

is

will NOT

is NOT

will

is NOT

will NOT

A.

B.

C.

D.

Page 70 of 75

ILT-21 RO NRC

71.

Initial conditions:

- Unit 2 reactor trip and SI occurred due to a steam line break.

- 19241-2, "Response to Imminent Pressurized Thermal Shock Condition," is in

progress.

Current conditions:

- An RCS soak is initiated.

- Crew is continuing in 19010-2, "Loss of Reactor or Secondary Coolant," while the

soak is in progress.

- The crew is at the step to "Stop Containment Spray Pumps."

Which one of the following completes the following statement?

Per 19241-2, stopping the Containment Spray pumps __(1)__ allowed,

and

after the RCS soak is complete, the RCS cold leg cooldown rate is limited to a

maximum of __(2)__ °F in any 60 minute period.

__(1)__

__(2)__

is

50

is

100

is NOT

50

is NOT

100

A.

B.

C.

D.

Page 71 of 75

ILT-21 RO NRC

72.

Given the following:

- Unit 1 reactor tripped due to a loss of off-site power.

- 19003-1, "Natural Circulation Cooldown with Void in Vessel (With RVLIS)," is in

progress.

Which one of the following completes the following statement?

Per 19003-1, the first Train of RHR can be placed in service when RCS hot leg

temperatures first lower to less than __(1)__ °F,

and

if a valid YELLOW path on inventory occurs during the performance of the cooldown,

19003-1 __(2)__ allow the crew to transition to 19263-1, "Response to Voids in

Reactor Vessel."

__(1)__

__(2)__

250

does

250

does NOT

350

does

350

does NOT

A.

B.

C.

D.

Page 72 of 75

ILT-21 RO NRC

73.

Initial conditions:

- Unit 1 reactor trip and SI occurred due to a large break LOCA.

- Containment pressure is 23 psig.

- Both Containment Spray (CS) pumps are running.

- RWST level is 26% and lowering.

- Four Containment Coolers are running in low speed.

- 19111-1, "Loss of Emergency Coolant Recirculation," is in progress.

Current condition:

- The crew is at the step to "Determine Containment Spray requirements."

Which one of the following completes the following statement?

Per 19111-1, the first major action the crew will attempt to perform is to __(1)__,

and

based on the current conditions, __(2)__ CS pump(s) is (are) required to be running.

REFERENCES PROVIDED

(1) increase / conserve RWST inventory

(2) 0

(1) increase / conserve RWST inventory

(2) 1

(1) depressurize RCS to minimize RCS subcooling

(2) 0

(1) depressurize RCS to minimize RCS subcooling

(2) 1

A.

B.

C.

D.

Page 73 of 75

ILT-21 RO NRC

74.

Initial conditions:

- Unit 1 reactor trip and SI occurred.

- 19121-1, "Uncontrolled Depressurization of All Steam Generators," is in

progress.

- RCS cold leg cooldown rate is 175 °F/hour.

- All SG NR levels are off-scale low.

- RCS pressure is 450 psig and stable.

- SI is reset.

- RHR pumps are stopped.

Current conditions:

- RAT '1A' de-energizes due to a fault.

- DG1A starts and re-energizes its associated bus.

- RCS pressure is 200 psig and lowering.

Which one of the following completes the following statements?

Based on the given conditions, the crew __(1)__ required to maintain a minimum of

80 gpm AFW to each SG.

Based on the given conditions, the crew __(2)__ required to manually start RHR pump

'A'.

__(1)__

__(2)__

is

is

is

is NOT

is NOT

is

is NOT

is NOT

A.

B.

C.

D.

Page 74 of 75

ILT-21 RO NRC

75.

Initial condition:

- Unit 1 reactor trip and SI occurred due to a LOCA.

Current conditions:

- 1LR-7777, Containment North and South Normal Sump Levels, indicate

off-scale high.

- 1LI-764 and 1LI-765, Containment North and South Emergency Sump Levels,

indicate 46 inches each.

Which one of the following completes the following statement?

Based on the given conditions, entry into 19252-1, "Response to Containment

Flooding," __(1)__ required,

and

the primary risk associated with flooding in containment is damage to __(2)__.

__(1)__

__(2)__

is

the containment inner liner

is

critical systems and components

is NOT

the containment inner liner

is NOT

critical systems and components

A.

B.

C.

D.

Page 75 of 75

ILT-21 RO Exam Provided References Index

1.

Unit 1 Pressure Temperature Limits Report (PTLR), Figure 2-1, Vogtle Unit 1

Reactor Coolant System Heat-up Limitations (rev. 5.0)

2.

19111-1, Loss of Emergency Coolant Recirculation, Page 9 (rev. 7.0)