DCL-14-081, Diablo Canyon Units 1 and 2, Central Coastal California Seismic Imaging Project (Cccsip) Chapter 9, GEO.DCPP.TR.14.01 R0 App A-E Figures 07-31-14

From kanterella
(Redirected from ML14260A065)
Jump to navigation Jump to search
Diablo Canyon Units 1 and 2, Central Coastal California Seismic Imaging Project (Cccsip) Chapter 9, GEO.DCPP.TR.14.01 R0 App A-E Figures 07-31-14
ML14260A065
Person / Time
Site: Diablo Canyon  Pacific Gas & Electric icon.png
Issue date: 09/10/2014
From:
Lettis Consultants International, Pacific Gas & Electric Co
To:
Office of Nuclear Reactor Regulation
Shared Package
ML14260A106 List: ... further results
References
DCL-14-081
Download: ML14260A065 (90)


Text

Page A1 of 2 GEO. DCPP.TR.14.01, Rev. 0 APPENDIX A: DAILY FIELD REPORTS (ELECTRONIC APPENDIX)

SUMMARY

Appendix A includes digital copies of handwritten daily field reports generated by Geologic Mapping Project teams during fiel d exercises in July and August 2012 and February 2013. The field reports include notes for the day's geologic mapping exercise(s) and documentation of daily field equipment verification. Files are labeled by field work instruction number "WI.XX" and month/day date. The digital files are in PDF format, as follows: Daily_Field_Rpt_WI.01_0709.pdf Daily_Field_Rpt_WI.01_0710.pdf Daily_Field_Rpt_WI.01_0711.pdf Daily_Field_Rpt_WI.02_0711.pdf Daily_Field_Rpt_WI.02_0712.pdf Daily_Field_Rpt_WI.03_0712.pdf Daily_Field_Rpt_WI.03_0713.pdf Daily_Field_Rpt_WI.04_0801.pdf Daily_Field_Rpt_WI.04_0802.pdf Daily_Field_Rpt_WI.06_0730.pdf Daily_Field_Rpt_WI.06_0731.pdf Daily_Field_Rpt_WI.07_0711.pdf Daily_Field_Rpt_WI.07_0713.pdf Daily_Field_Rpt_WI.07_WI.09_0712.pdf Daily_Field_Rpt_WI.08_0801.pdf Daily_Field_Rpt_WI.10_0710.pdf Daily_Field_Rpt_WI.11_0802.pdf Daily_Field_Rpt_WI.12_0802.pdf Daily_Field_Rpt_WI.13_0801.pdf Daily_Field_Rpt_WI.13_0802.pdf Daily_Field_Rpt_WI.15_0730.pdf Daily_Field_Rpt_WI.15_0803.pdf Daily_Field_Rpt_WI.16_0730.pdf Daily_Field_Rpt_WI.16_0731.pdf Daily_Field_Rpt_WI.17_0731.pdf Daily_Field_Rpt_WI.27_0204.pdf Daily_Field_Rpt_WI.27_0205.pdf Daily_Field_Rpt_WI.27_0206.pdf Page A2 of 2 GEO. DCPP.TR.14.01, Rev. 0 Daily_Field_Rpt_WI.27_0207.pdf Daily_Field_Rpt_WI.27_0208.pdf (last in list)

Page B1 of 1 GEO. DCPP.TR.14.01, Rev. 0 APPENDIX B: FIELD PHOTOGRAPHS (ELECTRONIC APPENDIX)

SUMMARY

Appendix B contains field photographs taken by Geologic Mapping Project (GMP) geologists during field mapping in July and August 2012 and February 2013. A GIS shapefile of all GMP field stations (Strik e_Dip_Field_GMP.shp) contains links between field station locations and photographs. Photographs are named by the last initials of the mapping group members followed by the photo number assigned by the camera. A duplicate set of photographs is included and is grouped by work instruction number followed by year, month, and day for cross-refe rencing with the daily field reports in Appendix A. Figure B-1 shows the locations of field photographs. Appendix B includes a Readme text file with instructions for linking field photographs to GIS field station points. Except for the Readme file, which is in TXT format, all files are in JPG format, as follows: GIS_Linked_Photos WI01_20120709 WI01_20120710 WI01_WI02_20120711 WI02_WI03_20120712 WI03_20120713 WI04_20120801 WI04_20120802 WI06_20120730 WI06_20120731 WI07_20120711 WI07_20120713 WI07_WI09_20120712 WI08_20120801 WI10_20120710 WI11_WI12_20120802 WI13_20120801 WI13_20120802 WI15_20120730 WI15_20120803 WI16_20120730 WI16_20120731 WI17_20120731 WI27_20130208 (last in list)

File path: S:\1005\020\QA_GIS\Final_Figures\Figure_B-1.mxd; Date: 06/03/2014; User: Alex Remar, LCI!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!

!!!!!!!

!!

!!!!!!!!!!!!!!!!!!!

!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!

!!!!!!!!!!!!!

!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!

!!!!!

!!!!!!!!!!!!!!!!!

!!!!!!!!!!!!!!!!!!!

!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!

!!!

!!!!!!!!

!!!

!!!!!!!!!!

!!!!

!!!!!!!!!!!!

!!!!!!!

!!!!!!!!!!!!!!!!!

!!!!!!!!!!!!!!

!!!!

!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!

!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!

!!!!!!!!!!!!!!!!

!!!!!!!

!!

!!!!!!!!!!

!!

!!

!!!!!!!

!!!!!!!

!!!!!!!

!!

!!!!!!!!!!!!!!!!!!!!!

!!!!!!!!!!!!!!!!!!!!!!

!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!

!

!!

!!

!!

!!!

!!!!!!!!

!!!

!!!

!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!

!!!!!!!!!!!!!!!!

!!!!!!!!!!!!!!!

!!

!!!

!

!!!!!!!!!!!!!!

!

!!!

!!!!!!!!!!

!!

!!!!!!!!!!

!!!!!!!!!!!!!!!!!!!!

!!!

!!!

!!!!!!!!

!!!!!!!!!!!

!!

!!!!

!!!!!!!!!!!!

!!!!!!!!!!!!

!!!!!!!!!!!!!!!!!

!!!!!!!!!!!!!!!

!!!!

!!!!

!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!

!

!!

!!

!!!

!!!

!!

!!

!!

!

!!

!!!!

!!!

!!!!!!

!!!!!!

!!!!!!!!

!!!!

!

!!

!

!!

!!

!

!!

!!!

!!

!!!!

!!!!!!!!

!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!

!!!!!

!!

!!!!

!!

!!!

!!!!

!!!

!!!!

!!!!!!!!!!!!!

!!!!!!!!!!!!!!!!!!!!

!!!!!!

!!!

!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!

!!!!!!!!!

!!

!!!!!!!!!!!!!!!!!!!!!!!!

!!!!!!!

!!

!!

!!!!!

!!

!!!!

!!

!!!!!!!!!!!!!!!!!!!!!!!!!

!!!

!!!

!!!!!!

!!!!!!

!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!

!!!!!!!!!!!!!!!!!!!!!!!!!!!!

!!!!!!!!!!!!

!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!

!!!!!

!

!!!!

!!

!!!!!!!!!!!!!

!!!

!!!!!!

!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!

!!!!!!!!!

!!!

!!!!!!!!!!!

!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!

!!!!

!!!!!!!!!!!!

!!!!!!!!!!!!!!!!!!!!!!!!!!!

!!!

!!!!!!!!!!!!!!!!!

!!

!!!!

!!!

!!!!!!!!!!!!!!

!!!!!

!!

!!

!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!

!!!!

!!!!!

!

!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!

!!!!!!!!!!!!!!!!!!!!!!!!

!!!!!!

!!!!!!!!!!

!!!!!!!!!!!!!!!!!!!!

!!!!

!!!

!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!

!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!

!!!!!!!!!!!!!!!!!!!!!!!!!!

!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!

!!!!!!!!!!!!!!

!!!!!!!!!!!!!!!!!!!!!!!!

!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!

!!!

!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!

!!!!!

!!!!!!!!!!!!!!!!!!!

!!!!!!!!!!!!!!!!

!!!!!!!!!!

!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!

!!!

!!!!!!!!!!!!!!!!!

!

!!!!!!!!!!!!!!

!!!!!!!!!!!!!!!!!!!

!!!!!!!!!

!!!!!!!!!!!!!!!

!!!!

!!!!!!!!!!!

!

!

!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!

!!!!!!!!

!!!!!!!

!!

!

!!!!

!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!

!

!!!!

!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!

!!!!!!!!!!!!!!!

!!!!!!!!!!!!!!!!!!!

!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!

!!

!!!!!!!!!!!!

!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!

!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!

!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!

!!!!

!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!

!!!!!!!!!!!!!!!!!!!!

!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!

!!!!!!!!!

!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!

!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!

!!!!!!!!!!!!!!

!!!!!!!!!!!

!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!

!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!

!!!!!!!!!!!!!!!!!!!!!!!!!

!!!!!!!!!

!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!

!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!

!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!

!

!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!

!!!!!!!!

!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!

!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!

!!!!!!!!!!!!!!!!

!!!!!!!!!

!!!!!!!!!!!!!!

!!!!!!!!!!

!!!!!!!!!!!!!!!!!!!!!!!!

!!

!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!

!!!!!!!

!!!!

!!!!!!!!!

!!!!!!!!!!!!!!!!!

!!!!!!!!!!!!!!!!!!

!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!

!!!!!!!!!!!!!

!!!!!!!!!!!!!!!!!!

!!!

!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!

!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!

!!!!!!!!!!!!!!

!!!!!!!!!!!

!!!!!!

!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!

!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!

!!!!!!!!!!!!!

!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!

!!!!!!!

!!!

!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!

!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!

!!!!!!!!!!

!!!!!!!!!!!!

!!!!!!!!

!!!!!!!!!!!!!!!!!!!!!!!

!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!

!!!!

!!!!!!!!!!!!!!!!!!!

!!!!!!

!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!

!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!

!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!

!!!!!!!!!!!!!!!!!!

!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!

!!

!!!!

!

!!!!

!!!!

!

!!!!

!!!!

!!!!!

!!!!!!!

!!!!!!!!

!!!

!!!!

!!!!

!

!!

!!!

!!

!!

!

!!!!

!

!!

!!!

!!

!!

!!!

!!

!!!!!!

!

!!!!

!!!!

!!!!

!!!

!!!!

!!!

!!

!!!

!!

!!

!!

!!!

!

!!

!!

!

!!

!!

!

!!

!

!!

!!!

!!

!!

!

!!

!

!!

!!

!

!!

!!!

!!

!!

!

!!

!

!!

!!

!!!

!!

!!

!

!!

!

!!

!!!!

!

!!!!

!!!

!!!!

!!!!

!!!

!!!!

!!

!!!

!!!!

!!!!

!!!

!!!!

!!!!

!

!!!!

!!!!

!!!

!!!!

!!!!

!

!!!!

!!!!!

!!

!!!!

!!!

!!!!

!!!!

!!!

!!!!

!!!!

!

!!!!

!!!

!!!!

!!!!!!

!!!!!

!!!!

!!!!!!

!!!!

!!!!!

!!!!

!!!!!!

!!!!!

!!!!

!!!!!!

!!!!!

!!

!!!!!!

!!!!!

!!!!

!!!!!!

!!!!

!!!!

!!!

!!!!

!!!!

!

!!!!

!

!!

!!!

!!

!

!!

!!

!

!!!!

!

!!

!!

!!!

!!!!

!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!

!!!!

!!!

!!

!

!!!!

!!

!

!!!!

!!!

!!

!!!!

!

!!!!!!!!!!!!

!

!!

!!

!!

!

!!

!!

!

!!!!

!

!!!!!!!!!!!!!!!!!!!!

!!!!!!!!

!!!!!!!!

!!!!!

!!!!!!!!!!!!

!!

!!!!

!!

!

!!!!

!

!!!!

!!!!!!

!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!

!

!!!!!!!!!!!!!!!!!!!!

!!!!!!!!!!!!!!!!!!!!!!!!!!

!!!!!!!!!!!!!!!!!!!!!!!!!!

!!!!!!!!!!!!

!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!

!!!

!!!!

!!!!

!!!!!!

!!!

!!

!!!!

!!

!!!!!!!!!!!!!!!!!!!!!!!

!

!!

!!

!

!!

!!

!

!!!!

!!!!!!!!!

!

!!

!!

!

!!

!!!!

!!!

!!!!

!!!!!!

!!!!

!!!!!

!!!!

!!!!

!

!!!!!!!!!

!!!!!!!!!!!!

!!!!

!!

!

!!

!!

!!

!!!

!!

!

!!!!

!!!

!!

!!!!

!

!!

!!

!

!!!!

!

!!

!!

!

!!

!!!!

!

!!

!!

!

!!

!!

!!!

!!

!

!!!!!

!

!!!!!

!!!!!!!!

!!

!

!!

!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!

!!

!!

!!!

!!

!!

!

!!

!!

!

!!

!!

!

!!!!!!!!!!!!!!!!!!!!!!

!!

!!!

!!

!!

!

!!

!!!!

!

!!

!!

!

!!

!!

!

!!!!

!

!!

!!

!!!

!!

!

!!

!!

!

!!

!!!!!!

!!

!!!

!!!!

!!!!

!!!!!!

!!!!!!

!!!!!!!!!

!!!!

!!!

!!

!!!!

!

!!!!!!!!!!!

!

!!!!!!!

!!

!

!!

!!

!

!!!!

!!

!

!!

!!!!!!!!!

!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!

!!!!!!!!!!

!!!!!!!!!

!!!!

!!!!!!

!!!!!!!!!!!!

!!

!

!!!!

!

!!

!!

!

!!

!!!!

!!!!!!!!!!!!!!!!!!!!!!!!!!

!!

!!!!

!!!!!!!!!!!!!

!!!!

!!!

!!

!!

!!!!!!

!!!!!!!!!!!!!!!!!!!!

!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!

!!

!!

!!!!

!!!!!

!

!!!!

!!!!!!!!!!!!!!!!!!!

!!

!!!!!!

!!!!

!!

!

!!

!!

!

!!

!!

!

!!!!!!

!!!!

!!!!

!!

!!!!!!

!!!!!

!!!!!!

!!!!!!!!

!!

!!!!!!!

!!!!!!

!!!!

!!!

!!!!

!!

!

!!!!

!!!!!!

!!!!!!!!!!!

!!!!!!!!

!!!!!!!!!!!

!!!!!!!!!!!

!!!!!

!!!!!!!!!!!!!!!!!!

!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!

!!!!!!!!!!!!!!!!!!!!!!!!!!

!!

!!!

!!

!

!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!

!

!!!!

!

!!

!!

!

!!

!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!

!!

!!

!!!!!!

!!!!!!

!!!!!!

!!!!!!!!

!!!!!!!!!!!!!!!!!!!

!!!!!!

!!!

!!

!!!!

!

!!!!

!

!!

!!

!!!

!!

!

!!

!!!!

!

!!!!

!

!!!!

!!

!

!!

!

!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!

!!!!

!

!!!!

!!!

!!

!!

!

!!

!!

!

!!!!

!!

!

!!!!

!!

!!!

!!

!

!!

!!

!

!!

!!!

!!

!!

!!!!!!!!!!

!!!

!!

!

!!

!!

!

!!

!!!!!!

!!

!!

!

!!!!

!

!!!!

!!

!

!!

!!!

!!

!!

!!!

!!

!!

!

!!

!

!!

!!

!

!!!!!

!!

!!

!

!!

!!!

!!

!!!!

!

!!!!

!!

!

!!!!

!

!!

!!

!

!!

!!!

!!

!!

!

!!

!!

!

!!

!

!!

!!

!

!!!!

!

!!

!!!

!!

!

!!

!!

!!!!!!!!!!!!!!

!!!

!!!!!!!!!

!!!!!!!!!!!!!!!!!!

!!!!!!!!!!!!!!!!!!!!!!!!!!

!!!!!!!!!!!!!!!!!

!!

!

!!!!!!

!!!!!!!

!!!!!!

!!

!

!!

!!!

!!

!!!

!!

!!!

!!

!!!!

!

!!!!

!!!

!!!!

!!!

!!

!!

!

!!!!

!

!!

!

!!

!!!!

!

!!

!!

!!

!!!

!!!

!!

!!!!!!

!!!!

!

!!!!!

!!!

!!

!!

!

!!

!!

!

!!

!

!!

!!

!!

!!!

!

!!!!!!!!!

!!

!!!

!!

!

!!

!!

!!!

!!

!

!!

!!

!!

!

!!

!!!!!

!!

!

!!

!!

!

!!!!

!

!!

!!!!

!!!

!!!!!!!!!!!!!!!!!!!!!!!!

!!

!!

!!

!!!

!!

!!!

!!

!!!

!!

!!!

!!

!!!!

!

!!!!!!

!!!!!!!!!!!!!!!!!!!

!!

!!!!!

!!

!!!!!!

!!

!

!!

!

!!!!

!!!

!!

!!!!!!!!!!!!!!!!!!!!!!!!!

!!

!!!!!!

!!!!

!!

!

!!!!

!

!!

!!!

!!!!

!!!!!!!!

!!!!

!

!!

!!!!!!!!!!!!!!!!!!!!!!!!

!!!!!!

!!!

!!!!

!!

!

!!!!

!

!!

!!!!

!

!!!!

!

!!

!!!

!!!!

!!

!

!!!!!!

!!!!!

!

!!!!!!!

!

!!!!

!!!!!!

!!!!!

!!

!!

!!

!!!

!!

!!!

!!

!!

!!!

!!

!

!!!!

!!

!!

!

!!

!

!!!!

!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!

!!!!!!!!

!!!!!!!!!!

!!!!!!!!!!!

!!!!!!!!

!!!!!!!!!!!!!

!!!!!!

!!!!!!!!

!!!!!!

!!!!!

!!

!

!!

!!

!!!

!!!!

!

!!

!!

!

!!

!!

!!

!

!!

!!!!!!

!!!!!!

!!!!!!!!

!!!!

!

!!

!

!!

!!

!

!!

!!!

!!

!!!!

!!!!!!!!

!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!

!!!!!!

!!!!

!!!

!!

!!!!

!!!

!!!!

!!!!

!!!

!!!!!!!!!!!!!

!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!

!!!

!!!!

!!!!

!!!!

!!!!

!

!!!!

!!!!

!!!!!!

!!!

!!

!!!!!!

!!!!

!!!!

!!!!

!!!!

!

!!!!

!!!!!!

!!!!

!!!

!!

!!!!

!!!!

!!!

!!

!!!!!!

!!!!

!!!!

!!!!!

!!!!

!!!!

!!

!!!

!!

!!!!

!

!!

!!!!!!!!!

!!!!

!!!!!!

!!!!

!!!!!!

!!!!

!!!!

!!!!

!!!

!!!!

!!!!!!!!!!!

!!!!

!!!!

!!!

!!!!

!!!!

!!!!

!!!!!!

!!!!

!!!!

!

!!!!!!!!!

!!!!!

!!!!!!

!!!!!!!!!!!!!!!!!!!!!

!!!!!!

!!!

!!!!

!!!!

!

!!!!

!!

!

!!!!

!

!!

!!

!

!!

!!!

!!

!!

!!!!!!

!!

!!

!

!!

!!

!

!!

!!

!

!!

!!

!

!!

!!

!

!!

!!

!

!!

!!

!

!!

!

!!

!!

!

!!

!!

!

!!

!!

!

!!

!!

!

!!

!!

!

!!

!!

!

!!

!!!

!!

!!!!

!!!!!!!!

!!!!!!

!!!!!!

!!!!

!!!

!!

!!!

!!

!!

!!!

!!

!!

!

!!

!

!!

!!

!!

!

!!

!

!!!!

!

!!

!!!!

!

!!!!

!!!!!!

!!!!!!

!!!!!!

!!!!!!

!

!!!!

!!!!

!

!!!!

!

!!

!!

!

!!

!!

!

!!

!

!!

!!!

!!

!!

!

!!

!!

!

!!

!!

!

!!

!

!!

!!

!

!!

!!

!

!!

!!

!

!!

!!

!

!!

!

!!

!!

!

!!

!!

!

!!

!!

!

!!

!!

!

!!

!

!!

!!

!

!!

!!

!

!!

!!

!

!!

!

!!

!!!

!!

!!

!

!!

!

!!

!!

!

!!

!!

!

!!

!

!!

!!!

!!

!!

!!!

!!

!!!

!!!!

!!

!!!!!

!!!!

!!!!

!!!!!

!!!!

!!!!

!

!!!!

!

!!!!

!

!!

!!!

!!

!!

!

!!

!!

!

!!!!

!

!!

!

!!

!!

!!!

!!!!!!

!!!!!

!!

!!!!

!!!

!!

!!!

!!

!!!

!!!!

!!!!!!!!!!!!!!

!!!!

!

!!!!

!!

!

!!

!

!!

!!

!

!!

!

!!!!

!!!!!!

!!!

!!

!!

!

!!!!!

!!

!

!!!!

!!!

!!!

!!!!

!

!!!!!!!

!

!!

!

!!

!!

!

!!!

!!

!!

!

!!

!!

!

!!!

!!

!!

!

!!

!!!

!!

!!!!!!!!!!!!!

!!!

!!!

!!

!!!!

!!!!!!!!!!!!!!!!!!

!!!!

!!!!

!

!!!!

!!!

!!!!!

!!

!!!!

!

!!!!

!

!!

!!

!!!!!

!!!

!!

!!!!

!!

!

!!

!!!

!!

!!

!!!

!!!!

!

!!!

!!

!!

!

!!!!

!

!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!

!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!

!!!!!!

!!!!!!

!!!!

!!!

!!!!

!!!!!!

!!!

!!!!!!

!!!!

!!!!!!

!!!!!!

!!!!!!!

!!!!

!!!!!!!!!!

!!!!!!!!

!!

!

!!

!!!!!!!!!!!!!!

!!!!

!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!

!!!!!!!!!!!!

!!!!!!!!!!

!!!

!!

!!

!!

!

!!!!

!!

!

!!!!

!!!!

!

!!!!

!!!

!!

!!!!!!

!!!

!!!!!!!!!!!

!!!

!!

!!!

!!

!!

!

!!

!!

!!!

!!

!

!!

!!

!

!!

!

!!!!

!

!!

!!!

!!

!!

!

!!!!!

!!

!

!!!!

!

!!

!

!!!!

!!!!!!!!

!!

!

!!

!!!

!!

!!

!

!!

!!!

!!

!!

!

!!

!

!!

!!

!

!!

!!

!

!!

!!

!!!

!

!!!!

!!

!!!

!!

!

!!

!!

!!!

!

!!

!!

!

!!

!!

!

!!

!

!!

!!

!

!!

!!

!

!!!

!!!!

!

!!!!

!

!!

!!

!!!

!!

!

!!!!

!

!!!!

!

!!!!

!

!!

!!!

!!

!!!!

!

!!!!

!

!!

!!!

!!

!!!!

!

!!

!!!

!!

!!!

!!

!!

!!!

!!

!!!

!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!

!!!!!!!!

!!!!

!

!!

!

!!

!

!!

!!!!

!!!!!!!!!!!!!!!!!!!!!!!!!!!!!

!!!!!!!

!!!!

!!!!

!!!!!

!!!!

!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!

!!!!!!!!

!!!!!!

!!!

!!!!!!

!!!!!!

!!!!!!!!!!!!!!!!!!!!!

!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!

!

!!!!!!

!!!!!

!!

!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!

!

!!!!!!!!!!!!!!!!!!!!!!!

!

!!

!!!!!!!!

!!

!!!

!!

!!!!

!!!!

!!!!!!!!

!!!!!!!!

!!!!

!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!

!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!

!!!

!!

!

!!!!

!

!!

!!

!

!!!!

!

!!

!

!!

!!

!

!!

!!

!

!!

!!

!

!!

!!!!!!

!!!!!!!

!

!!!

!

!!!

!

!!!!!!!

!!!!

!!!!!

!!!!!!!!

!!!

!

!!!

!!!!

!!!!!

!!!!

!!!

!

!!!

!

!!!!!!!

!!!!!

!!!!

!!!

!!!!

!

!!!

!!!!

!!!!!

!!!!

!

!!

!!

!

!!

!!

!!!

!!

!

!!

!!

!

!!

!!!

!!

!

!!

!!

!

!!

!!!

!!

!

!!

!!

!

!!

!!!

!!

!!

!

!!

!!

!

!!!!

!!!

!!

!!!!

!!!

!!!!

!!!

!!

!!!!

!

!!!!

!!!!

!!!

!!!!

!

!!!!

!!!!!!!!!!!!!!!

!!!!!

!!!!

!!!!!!!!!!!

!

!!!!

!!!

!!

!!!!

!!!

!!!!

!!!

!!

!!!

!!!!

!!!

!!

!!!!

!!!

!!!!

!!!!!!

!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!

!

!!

!!

!

!!

!!

!

!!

!!

!

!!

!!

!

!!

!!!!!!

!!!

!!

!!!!

!!!

!!!!

!!

!!!

!!

!!

!

!!

!!!

!!

!!

!

!!

!!!!!!

!!

!!!

!

!!!!

!

!!

!!!

!!!!

!!

!!!

!!

!

!!

!!

!

!!

!!

!!!

!!

!!!!

!!!

!!!!!!!!!!!!!!!!!!

!!!!!!!!

!!!

!!

!!!!

!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!

!!!!!!

!!!!!!!!

!!

!!

!!

!

!!

!!!

!!

!!!!

!!!!!!!!!!!!!!!!!!

!

!!!!

!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!

!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!

!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!

!!!!

!!!!!

!!!

!!

!!

!!

!

!!!!

!!

!!!!!!!!!!!!!!!!!!!

!!!!!!

!!!!!!!!!!

!!!!!!

!!!!

!!!!!!!!

!!!!

!!

!

!!

!!

!

!!

!!

!!

!

!!

!!

!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!

!!!!!

!!!!!!!!!!!!!!!!

!!!!!

!!!!!!!!!!

!!!!

!

!!!!!!!!!!!!!!!

!!

!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!

!!!!

!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!

!!!!!

!!!!!!!

!!!!!

!!!!!!!!!!!!!!

!!!!

!!!!!!

!!!!!!!!

!!

!

!!

!!!!

!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!

!!

!!!!!!!!!!!

!!!!

!!!!!!!!!!!!!!!!!!!!!!!!!!!

!

!

!!!!!!!

!!!

!!!

!!!!!

!!!!!!

!!!!

!!!

!!

!!!!!

!!

!!!

!!

!!

!

!!

!!

!!!

!!!!!

!

!!!!

!

!!

!

!!

!!

!!

!!!

!!

!

!!

!!!!!

!!

!

!!

!

!!

!!

!!

!

!!

!!!!!!!

!

!!

!!!!!!!!

!!!!!!!!!!!!!!!!!!!!!

!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!

!!!!!!!!!!!!!!!!!!!

!!

!

!!

!!

!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!

!

!!!!

!!!!

!!!

!!!!!!!!!!!

!!!!!!

!!

!!

!

!!

!!!

!!

!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!

!!

!

!!!!!!!!!!

!!

!!

!

!!

!!!!!!!!!!!!!!!!!!

!!!!

!!

!

!!

!!!!!!!!

!!!!

!!

!!

!

!!

!!

!!!

!!

!!

!!

!

!!

!!!!!!

!!

!!!!!!

!!!!!!!!!!!

!

!!

!!!!

!

!!!!

!

!!!!!!!!!!!!!!!!!!!!!

!!

!!

!

!!

!!

!!!!!

!!

!

!!

!!!!!!!!!!!

!

!!

!!!!!!

!!

!!

!!!!

!!!!!!!

!!!!!!!

!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!

!!!!

!!!!

!!

!!!!

!!!!!!!!!!!!!!

!!

!!!!!!!!!

!!!!!!!!!!!!!!!

!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!

!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!

!

!!!!

!

!!

!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!

!

!!

!

!!!!

!!

!!

!

!!

!!!

!!!!

!!!!

!!

!!!!

!!!

!!!!!!!!!!!

!!!!!!

!!!!

!!!!

!!!

!!!!

!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!

!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!

!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!

!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!

!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!

!!!!

!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!

!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!

!!!!!!!

!!!!!!!!!!!!!!

!!!!!!!!!!!!!!

!!

!!

!!!

!!

!!

!

!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!

!!!!!!

!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!

!!!!!!!!!!!!!!!!!!!!!!!

!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!

!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!

!

!!!!

!!!

!!!!

!!

!

!!!!!!!!!!!!!!!!!!!!!!!!!!!!!

!!!!

!!

!

!!!

!!

!!

!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!

!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!

!!!!

!

!!

!

!!

!!!

!!!!

!

!!

!!!!!!!!!!!

!!!

!!!!

!!

!!!

!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!

!!!!

!

!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!

!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!

!!

!!!!

!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!

!!

!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!

!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!

!!

!!

!!!

!!!!!!!!!!!!!!!!!!!!!!!!!!

!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!

!!

!!

!

!!

!!!!!

!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!

!

!!

!!!

!!

!!

!!!!

!

!!!!!!!!!!

!!!!!!

!!!!!!!!!!

!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!

!!!!!!

!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!

!!

!!!!!!!!!!!

!!

!!!

!!

!!!!!!!!!!!!!!!!!!!

!!!

!!

!

!!

!!

!

!!!!

!

!!

!!

!!!

!!

!!!

!!

!!!

!!

!!!!!!!

!!!!!!

!!!!!!!

!

!!

!!

!

!!

!!

!

!!!

!!

!!

!

!!!!

!!!

!!

!!

!

!!!!

!!!!!!

!!!

!!!!

!!!!!!

!!!!!

!!!!

!!!!

!!!!

!!!

!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!

!

!!

!!!!

!!!

!!

!

!!

!!

!

!!

!

!!!

!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!

!!!!

!!!

!!

!!!!

!

!!!!

!!!

!!!!

!!!!

!!!!

!

!!!!

!

!!

!!!

!!!!

!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!

!!!!!!

!

!!!!!!

!!!!!

!!

!!!

!!!!

!!!!!!

!!!

!!

!!

!

!!!!

!

!!

!!!!

!

!!!!

!!!

!!!!!!

!!!!

!!!

!!

!

!!!!!!!

!!!

!!

!!

!

!!

!

!!

!!!

!!

!!!!

!!

!!!

!!

!

!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!

!!

!

!!

!!

!

!!

!!!!

!!!!!!!!!!

!!!!!!^_Irish Hillsstudy areaDCPPstudy areaPrice Canyonstudy areaPointBuchonPoint San Luis S T 1 S T 1 S T41 S T58 S T227£101AvilaBeachEdnaGardenFarmsLos OsosMorro BayPismo BeachPort SanLuisSan LuisObispoSantaMargaritaThyleDCPP-120°37'-120°37'-120°44'-120°44'-120°51'-120°51'35°25'35°25'35°18'35°18'35°11'35°11'Locations of Photographs

^_Arroyo GrandeSanta BarbaraDCPPDCPP GEOLOGIC MAPPING PROJECTPacific Gas and Electric CompanyFigure extent

+/-0 2 4mi.0 4 8kmEXPLANATIONPhotograph location

!2011 Vibroseis line2011 AWD line and 2011 Vibroseis line2011 AWD lineSeismic Reflection SurveyB-1Figure1:175,000NAD 83 / UTM Zone 10N,Map projection and scale:!!!!!!!!!!!!!!!!!!!!!

!!!!!!!!!!!!!!!!!!!!!

!!!!!!!2012 high-resolution survey receiver array2011 nodal receiver array!!!!!!!!!!!!!!!!!!!!!

!!!!!!!!!!!!!!!!!!!!!

!!!!!!!2011 nodal receivers, no shotpoints Page C1 of 1 GEO. DCPP.TR.14.01, Rev. 0 APPENDIX C: FIELD SAMPLES (ELECTRONIC APPENDIX)

SUMMARY

Appendix C contains a spreadsheet of field samples collected by Geologic Mapping Project (GMP) geologists during field mapping in July and August 2012 and February 2013. The GIS shapefile of GMP field stations (Strike_Dip_Field_GMP.shp) includes in the attribute table whether a sample was collected. All field hand samples are being kept in the basement storage space at Lettis Consultants International's (LCI) offices in Walnut Creek. The hand samples will be retained for the duration of the seismic interpretation project, and will then be discarded. Figure C-1 shows the locations of field hand samples.

Appendix C consists of two digital files, as follows: FieldSamples.xls (Excel file) Readme.txt (Text file)

File path: S:\1005\020\QA_GIS\Final_Figures\Figure_C-1.mxd; Date: 06/03/2014; User: Alex Remar, LCI!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!

!!!!!!!

!!

!!!!!!!!!!!!!!!!!!!

!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!

!!!!!!!!!!!!!

!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!

!!!!!

!!!!!!!!!!!!!!!!!

!!!!!!!!!!!!!!!!!!!

!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!

!!!

!!!!!!!!

!!!

!!!!!!!!!!

!!!!

!!!!!!!!!!!!

!!!!!!!

!!!!!!!!!!!!!!!!!

!!!!!!!!!!!!!!

!!!!

!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!

!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!

!!!!!!!!!!!!!!!!

!!!!!!!

!!

!!!!!!!!!!

!!

!!

!!!!!!!

!!!!!!!

!!!!!!!

!!

!!!!!!!!!!!!!!!!!!!!!

!!!!!!!!!!!!!!!!!!!!!!

!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!

!

!!

!!

!!

!!!

!!!!!!!!

!!!

!!!

!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!

!!!!!!!!!!!!!!!!

!!!!!!!!!!!!!!!

!!

!!!

!

!!!!!!!!!!!!!!

!

!!!

!!!!!!!!!!

!!

!!!!!!!!!!

!!!!!!!!!!!!!!!!!!!!

!!!

!!!

!!!!!!!!

!!!!!!!!!!!

!!

!!!!

!!!!!!!!!!!!

!!!!!!!!!!!!

!!!!!!!!!!!!!!!!!

!!!!!!!!!!!!!!!

!!!!

!!!!

!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!

!

!!

!!

!!!

!!!

!!

!!

!!

!

!!

!!!!

!!!

!!!!!!

!!!!!!

!!!!!!!!

!!!!

!

!!

!

!!

!!

!

!!

!!!

!!

!!!!

!!!!!!!!

!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!

!!!!!

!!

!!!!

!!

!!!

!!!!

!!!

!!!!

!!!!!!!!!!!!!

!!!!!!!!!!!!!!!!!!!!

!!!!!!

!!!

!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!

!!!!!!!!!

!!

!!!!!!!!!!!!!!!!!!!!!!!!

!!!!!!!

!!

!!

!!!!!

!!

!!!!

!!

!!!!!!!!!!!!!!!!!!!!!!!!!

!!!

!!!

!!!!!!

!!!!!!

!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!

!!!!!!!!!!!!!!!!!!!!!!!!!!!!

!!!!!!!!!!!!

!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!

!!!!!

!

!!!!

!!

!!!!!!!!!!!!!

!!!

!!!!!!

!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!

!!!!!!!!!

!!!

!!!!!!!!!!!

!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!

!!!!

!!!!!!!!!!!!

!!!!!!!!!!!!!!!!!!!!!!!!!!!

!!!

!!!!!!!!!!!!!!!!!

!!

!!!!

!!!

!!!!!!!!!!!!!!

!!!!!

!!

!!

!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!

!!!!

!!!!!

!

!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!

!!!!!!!!!!!!!!!!!!!!!!!!

!!!!!!

!!!!!!!!!!

!!!!!!!!!!!!!!!!!!!!

!!!!

!!!

!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!

!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!

!!!!!!!!!!!!!!!!!!!!!!!!!!

!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!

!!!!!!!!!!!!!!

!!!!!!!!!!!!!!!!!!!!!!!!

!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!

!!!

!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!

!!!!!

!!!!!!!!!!!!!!!!!!!

!!!!!!!!!!!!!!!!

!!!!!!!!!!

!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!

!!!

!!!!!!!!!!!!!!!!!

!

!!!!!!!!!!!!!!

!!!!!!!!!!!!!!!!!!!

!!!!!!!!!

!!!!!!!!!!!!!!!

!!!!

!!!!!!!!!!!

!

!

!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!

!!!!!!!!

!!!!!!!

!!

!

!!!!

!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!

!

!!!!

!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!

!!!!!!!!!!!!!!!

!!!!!!!!!!!!!!!!!!!

!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!

!!

!!!!!!!!!!!!

!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!

!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!

!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!

!!!!

!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!

!!!!!!!!!!!!!!!!!!!!

!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!

!!!!!!!!!

!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!

!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!

!!!!!!!!!!!!!!

!!!!!!!!!!!

!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!

!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!

!!!!!!!!!!!!!!!!!!!!!!!!!

!!!!!!!!!

!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!

!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!

!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!

!

!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!

!!!!!!!!

!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!

!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!

!!!!!!!!!!!!!!!!

!!!!!!!!!

!!!!!!!!!!!!!!

!!!!!!!!!!

!!!!!!!!!!!!!!!!!!!!!!!!

!!

!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!

!!!!!!!

!!!!

!!!!!!!!!

!!!!!!!!!!!!!!!!!

!!!!!!!!!!!!!!!!!!

!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!

!!!!!!!!!!!!!

!!!!!!!!!!!!!!!!!!

!!!

!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!

!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!

!!!!!!!!!!!!!!

!!!!!!!!!!!

!!!!!!

!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!

!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!

!!!!!!!!!!!!!

!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!

!!!!!!!

!!!

!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!

!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!

!!!!!!!!!!

!!!!!!!!!!!!

!!!!!!!!

!!!!!!!!!!!!!!!!!!!!!!!

!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!

!!!!

!!!!!!!!!!!!!!!!!!!

!!!!!!

!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!

!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!

!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!

!!!!!!!!!!!!!!!!!!

!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!

!!

!!!!

!

!!!!

!!!!

!

!!!!

!!!!

!!!!!

!!!!!!!

!!!!!!!!

!!!

!!!!

!!!!

!

!!

!!!

!!

!!

!

!!!!

!

!!

!!!

!!

!!

!!!

!!

!!!!!!

!

!!!!

!!!!

!!!!

!!!

!!!!

!!!

!!

!!!

!!

!!

!!

!!!

!

!!

!!

!

!!

!!

!

!!

!

!!

!!!

!!

!!

!

!!

!

!!

!!

!

!!

!!!

!!

!!

!

!!

!

!!

!!

!!!

!!

!!

!

!!

!

!!

!!!!

!

!!!!

!!!

!!!!

!!!!

!!!

!!!!

!!

!!!

!!!!

!!!!

!!!

!!!!

!!!!

!

!!!!

!!!!

!!!

!!!!

!!!!

!

!!!!

!!!!!

!!

!!!!

!!!

!!!!

!!!!

!!!

!!!!

!!!!

!

!!!!

!!!

!!!!

!!!!!!

!!!!!

!!!!

!!!!!!

!!!!

!!!!!

!!!!

!!!!!!

!!!!!

!!!!

!!!!!!

!!!!!

!!

!!!!!!

!!!!!

!!!!

!!!!!!

!!!!

!!!!

!!!

!!!!

!!!!

!

!!!!

!

!!

!!!

!!

!

!!

!!

!

!!!!

!

!!

!!

!!!

!!!!

!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!

!!!!

!!!

!!

!

!!!!

!!

!

!!!!

!!!

!!

!!!!

!

!!!!!!!!!!!!

!

!!

!!

!!

!

!!

!!

!

!!!!

!

!!!!!!!!!!!!!!!!!!!!

!!!!!!!!

!!!!!!!!

!!!!!

!!!!!!!!!!!!

!!

!!!!

!!

!

!!!!

!

!!!!

!!!!!!

!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!

!

!!!!!!!!!!!!!!!!!!!!

!!!!!!!!!!!!!!!!!!!!!!!!!!

!!!!!!!!!!!!!!!!!!!!!!!!!!

!!!!!!!!!!!!

!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!

!!!

!!!!

!!!!

!!!!!!

!!!

!!

!!!!

!!

!!!!!!!!!!!!!!!!!!!!!!!

!

!!

!!

!

!!

!!

!

!!!!

!!!!!!!!!

!

!!

!!

!

!!

!!!!

!!!

!!!!

!!!!!!

!!!!

!!!!!

!!!!

!!!!

!

!!!!!!!!!

!!!!!!!!!!!!

!!!!

!!

!

!!

!!

!!

!!!

!!

!

!!!!

!!!

!!

!!!!

!

!!

!!

!

!!!!

!

!!

!!

!

!!

!!!!

!

!!

!!

!

!!

!!

!!!

!!

!

!!!!!

!

!!!!!

!!!!!!!!

!!

!

!!

!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!

!!

!!

!!!

!!

!!

!

!!

!!

!

!!

!!

!

!!!!!!!!!!!!!!!!!!!!!!

!!

!!!

!!

!!

!

!!

!!!!

!

!!

!!

!

!!

!!

!

!!!!

!

!!

!!

!!!

!!

!

!!

!!

!

!!

!!!!!!

!!

!!!

!!!!

!!!!

!!!!!!

!!!!!!

!!!!!!!!!

!!!!

!!!

!!

!!!!

!

!!!!!!!!!!!

!

!!!!!!!

!!

!

!!

!!

!

!!!!

!!

!

!!

!!!!!!!!!

!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!

!!!!!!!!!!

!!!!!!!!!

!!!!

!!!!!!

!!!!!!!!!!!!

!!

!

!!!!

!

!!

!!

!

!!

!!!!

!!!!!!!!!!!!!!!!!!!!!!!!!!

!!

!!!!

!!!!!!!!!!!!!

!!!!

!!!

!!

!!

!!!!!!

!!!!!!!!!!!!!!!!!!!!

!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!

!!

!!

!!!!

!!!!!

!

!!!!

!!!!!!!!!!!!!!!!!!!

!!

!!!!!!

!!!!

!!

!

!!

!!

!

!!

!!

!

!!!!!!

!!!!

!!!!

!!

!!!!!!

!!!!!

!!!!!!

!!!!!!!!

!!

!!!!!!!

!!!!!!

!!!!

!!!

!!!!

!!

!

!!!!

!!!!!!

!!!!!!!!!!!

!!!!!!!!

!!!!!!!!!!!

!!!!!!!!!!!

!!!!!

!!!!!!!!!!!!!!!!!!

!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!

!!!!!!!!!!!!!!!!!!!!!!!!!!

!!

!!!

!!

!

!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!

!

!!!!

!

!!

!!

!

!!

!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!

!!

!!

!!!!!!

!!!!!!

!!!!!!

!!!!!!!!

!!!!!!!!!!!!!!!!!!!

!!!!!!

!!!

!!

!!!!

!

!!!!

!

!!

!!

!!!

!!

!

!!

!!!!

!

!!!!

!

!!!!

!!

!

!!

!

!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!

!!!!

!

!!!!

!!!

!!

!!

!

!!

!!

!

!!!!

!!

!

!!!!

!!

!!!

!!

!

!!

!!

!

!!

!!!

!!

!!

!!!!!!!!!!

!!!

!!

!

!!

!!

!

!!

!!!!!!

!!

!!

!

!!!!

!

!!!!

!!

!

!!

!!!

!!

!!

!!!

!!

!!

!

!!

!

!!

!!

!

!!!!!

!!

!!

!

!!

!!!

!!

!!!!

!

!!!!

!!

!

!!!!

!

!!

!!

!

!!

!!!

!!

!!

!

!!

!!

!

!!

!

!!

!!

!

!!!!

!

!!

!!!

!!

!

!!

!!

!!!!!!!!!!!!!!

!!!

!!!!!!!!!

!!!!!!!!!!!!!!!!!!

!!!!!!!!!!!!!!!!!!!!!!!!!!

!!!!!!!!!!!!!!!!!

!!

!

!!!!!!

!!!!!!!

!!!!!!

!!

!

!!

!!!

!!

!!!

!!

!!!

!!

!!!!

!

!!!!

!!!

!!!!

!!!

!!

!!

!

!!!!

!

!!

!

!!

!!!!

!

!!

!!

!!

!!!

!!!

!!

!!!!!!

!!!!

!

!!!!!

!!!

!!

!!

!

!!

!!

!

!!

!

!!

!!

!!

!!!

!

!!!!!!!!!

!!

!!!

!!

!

!!

!!

!!!

!!

!

!!

!!

!!

!

!!

!!!!!

!!

!

!!

!!

!

!!!!

!

!!

!!!!

!!!

!!!!!!!!!!!!!!!!!!!!!!!!

!!

!!

!!

!!!

!!

!!!

!!

!!!

!!

!!!

!!

!!!!

!

!!!!!!

!!!!!!!!!!!!!!!!!!!

!!

!!!!!

!!

!!!!!!

!!

!

!!

!

!!!!

!!!

!!

!!!!!!!!!!!!!!!!!!!!!!!!!

!!

!!!!!!

!!!!

!!

!

!!!!

!

!!

!!!

!!!!

!!!!!!!!

!!!!

!

!!

!!!!!!!!!!!!!!!!!!!!!!!!

!!!!!!

!!!

!!!!

!!

!

!!!!

!

!!

!!!!

!

!!!!

!

!!

!!!

!!!!

!!

!

!!!!!!

!!!!!

!

!!!!!!!

!

!!!!

!!!!!!

!!!!!

!!

!!

!!

!!!

!!

!!!

!!

!!

!!!

!!

!

!!!!

!!

!!

!

!!

!

!!!!

!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!

!!!!!!!!

!!!!!!!!!!

!!!!!!!!!!!

!!!!!!!!

!!!!!!!!!!!!!

!!!!!!

!!!!!!!!

!!!!!!

!!!!!

!!

!

!!

!!

!!!

!!!!

!

!!

!!

!

!!

!!

!!

!

!!

!!!!!!

!!!!!!

!!!!!!!!

!!!!

!

!!

!

!!

!!

!

!!

!!!

!!

!!!!

!!!!!!!!

!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!

!!!!!!

!!!!

!!!

!!

!!!!

!!!

!!!!

!!!!

!!!

!!!!!!!!!!!!!

!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!

!!!

!!!!

!!!!

!!!!

!!!!

!

!!!!

!!!!

!!!!!!

!!!

!!

!!!!!!

!!!!

!!!!

!!!!

!!!!

!

!!!!

!!!!!!

!!!!

!!!

!!

!!!!

!!!!

!!!

!!

!!!!!!

!!!!

!!!!

!!!!!

!!!!

!!!!

!!

!!!

!!

!!!!

!

!!

!!!!!!!!!

!!!!

!!!!!!

!!!!

!!!!!!

!!!!

!!!!

!!!!

!!!

!!!!

!!!!!!!!!!!

!!!!

!!!!

!!!

!!!!

!!!!

!!!!

!!!!!!

!!!!

!!!!

!

!!!!!!!!!

!!!!!

!!!!!!

!!!!!!!!!!!!!!!!!!!!!

!!!!!!

!!!

!!!!

!!!!

!

!!!!

!!

!

!!!!

!

!!

!!

!

!!

!!!

!!

!!

!!!!!!

!!

!!

!

!!

!!

!

!!

!!

!

!!

!!

!

!!

!!

!

!!

!!

!

!!

!!

!

!!

!

!!

!!

!

!!

!!

!

!!

!!

!

!!

!!

!

!!

!!

!

!!

!!

!

!!

!!!

!!

!!!!

!!!!!!!!

!!!!!!

!!!!!!

!!!!

!!!

!!

!!!

!!

!!

!!!

!!

!!

!

!!

!

!!

!!

!!

!

!!

!

!!!!

!

!!

!!!!

!

!!!!

!!!!!!

!!!!!!

!!!!!!

!!!!!!

!

!!!!

!!!!

!

!!!!

!

!!

!!

!

!!

!!

!

!!

!

!!

!!!

!!

!!

!

!!

!!

!

!!

!!

!

!!

!

!!

!!

!

!!

!!

!

!!

!!

!

!!

!!

!

!!

!

!!

!!

!

!!

!!

!

!!

!!

!

!!

!!

!

!!

!

!!

!!

!

!!

!!

!

!!

!!

!

!!

!

!!

!!!

!!

!!

!

!!

!

!!

!!

!

!!

!!

!

!!

!

!!

!!!

!!

!!

!!!

!!

!!!

!!!!

!!

!!!!!

!!!!

!!!!

!!!!!

!!!!

!!!!

!

!!!!

!

!!!!

!

!!

!!!

!!

!!

!

!!

!!

!

!!!!

!

!!

!

!!

!!

!!!

!!!!!!

!!!!!

!!

!!!!

!!!

!!

!!!

!!

!!!

!!!!

!!!!!!!!!!!!!!

!!!!

!

!!!!

!!

!

!!

!

!!

!!

!

!!

!

!!!!

!!!!!!

!!!

!!

!!

!

!!!!!

!!

!

!!!!

!!!

!!!

!!!!

!

!!!!!!!

!

!!

!

!!

!!

!

!!!

!!

!!

!

!!

!!

!

!!!

!!

!!

!

!!

!!!

!!

!!!!!!!!!!!!!

!!!

!!!

!!

!!!!

!!!!!!!!!!!!!!!!!!

!!!!

!!!!

!

!!!!

!!!

!!!!!

!!

!!!!

!

!!!!

!

!!

!!

!!!!!

!!!

!!

!!!!

!!

!

!!

!!!

!!

!!

!!!

!!!!

!

!!!

!!

!!

!

!!!!

!

!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!

!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!

!!!!!!

!!!!!!

!!!!

!!!

!!!!

!!!!!!

!!!

!!!!!!

!!!!

!!!!!!

!!!!!!

!!!!!!!

!!!!

!!!!!!!!!!

!!!!!!!!

!!

!

!!

!!!!!!!!!!!!!!

!!!!

!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!

!!!!!!!!!!!!

!!!!!!!!!!

!!!

!!

!!

!!

!

!!!!

!!

!

!!!!

!!!!

!

!!!!

!!!

!!

!!!!!!

!!!

!!!!!!!!!!!

!!!

!!

!!!

!!

!!

!

!!

!!

!!!

!!

!

!!

!!

!

!!

!

!!!!

!

!!

!!!

!!

!!

!

!!!!!

!!

!

!!!!

!

!!

!

!!!!

!!!!!!!!

!!

!

!!

!!!

!!

!!

!

!!

!!!

!!

!!

!

!!

!

!!

!!

!

!!

!!

!

!!

!!

!!!

!

!!!!

!!

!!!

!!

!

!!

!!

!!!

!

!!

!!

!

!!

!!

!

!!

!

!!

!!

!

!!

!!

!

!!!

!!!!

!

!!!!

!

!!

!!

!!!

!!

!

!!!!

!

!!!!

!

!!!!

!

!!

!!!

!!

!!!!

!

!!!!

!

!!

!!!

!!

!!!!

!

!!

!!!

!!

!!!

!!

!!

!!!

!!

!!!

!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!

!!!!!!!!

!!!!

!

!!

!

!!

!

!!

!!!!

!!!!!!!!!!!!!!!!!!!!!!!!!!!!!

!!!!!!!

!!!!

!!!!

!!!!!

!!!!

!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!

!!!!!!!!

!!!!!!

!!!

!!!!!!

!!!!!!

!!!!!!!!!!!!!!!!!!!!!

!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!

!

!!!!!!

!!!!!

!!

!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!

!

!!!!!!!!!!!!!!!!!!!!!!!

!

!!

!!!!!!!!

!!

!!!

!!

!!!!

!!!!

!!!!!!!!

!!!!!!!!

!!!!

!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!

!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!

!!!

!!

!

!!!!

!

!!

!!

!

!!!!

!

!!

!

!!

!!

!

!!

!!

!

!!

!!

!

!!

!!!!!!

!!!!!!!

!

!!!

!

!!!

!

!!!!!!!

!!!!

!!!!!

!!!!!!!!

!!!

!

!!!

!!!!

!!!!!

!!!!

!!!

!

!!!

!

!!!!!!!

!!!!!

!!!!

!!!

!!!!

!

!!!

!!!!

!!!!!

!!!!

!

!!

!!

!

!!

!!

!!!

!!

!

!!

!!

!

!!

!!!

!!

!

!!

!!

!

!!

!!!

!!

!

!!

!!

!

!!

!!!

!!

!!

!

!!

!!

!

!!!!

!!!

!!

!!!!

!!!

!!!!

!!!

!!

!!!!

!

!!!!

!!!!

!!!

!!!!

!

!!!!

!!!!!!!!!!!!!!!

!!!!!

!!!!

!!!!!!!!!!!

!

!!!!

!!!

!!

!!!!

!!!

!!!!

!!!

!!

!!!

!!!!

!!!

!!

!!!!

!!!

!!!!

!!!!!!

!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!

!

!!

!!

!

!!

!!

!

!!

!!

!

!!

!!

!

!!

!!!!!!

!!!

!!

!!!!

!!!

!!!!

!!

!!!

!!

!!

!

!!

!!!

!!

!!

!

!!

!!!!!!

!!

!!!

!

!!!!

!

!!

!!!

!!!!

!!

!!!

!!

!

!!

!!

!

!!

!!

!!!

!!

!!!!

!!!

!!!!!!!!!!!!!!!!!!

!!!!!!!!

!!!

!!

!!!!

!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!

!!!!!!

!!!!!!!!

!!

!!

!!

!

!!

!!!

!!

!!!!

!!!!!!!!!!!!!!!!!!

!

!!!!

!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!

!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!

!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!

!!!!

!!!!!

!!!

!!

!!

!!

!

!!!!

!!

!!!!!!!!!!!!!!!!!!!

!!!!!!

!!!!!!!!!!

!!!!!!

!!!!

!!!!!!!!

!!!!

!!

!

!!

!!

!

!!

!!

!!

!

!!

!!

!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!

!!!!!

!!!!!!!!!!!!!!!!

!!!!!

!!!!!!!!!!

!!!!

!

!!!!!!!!!!!!!!!

!!

!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!

!!!!

!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!

!!!!!

!!!!!!!

!!!!!

!!!!!!!!!!!!!!

!!!!

!!!!!!

!!!!!!!!

!!

!

!!

!!!!

!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!

!!

!!!!!!!!!!!

!!!!

!!!!!!!!!!!!!!!!!!!!!!!!!!!

!

!

!!!!!!!

!!!

!!!

!!!!!

!!!!!!

!!!!

!!!

!!

!!!!!

!!

!!!

!!

!!

!

!!

!!

!!!

!!!!!

!

!!!!

!

!!

!

!!

!!

!!

!!!

!!

!

!!

!!!!!

!!

!

!!

!

!!

!!

!!

!

!!

!!!!!!!

!

!!

!!!!!!!!

!!!!!!!!!!!!!!!!!!!!!

!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!

!!!!!!!!!!!!!!!!!!!

!!

!

!!

!!

!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!

!

!!!!

!!!!

!!!

!!!!!!!!!!!

!!!!!!

!!

!!

!

!!

!!!

!!

!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!

!!

!

!!!!!!!!!!

!!

!!

!

!!

!!!!!!!!!!!!!!!!!!

!!!!

!!

!

!!

!!!!!!!!

!!!!

!!

!!

!

!!

!!

!!!

!!

!!

!!

!

!!

!!!!!!

!!

!!!!!!

!!!!!!!!!!!

!

!!

!!!!

!

!!!!

!

!!!!!!!!!!!!!!!!!!!!!

!!

!!

!

!!

!!

!!!!!

!!

!

!!

!!!!!!!!!!!

!

!!

!!!!!!

!!

!!

!!!!

!!!!!!!

!!!!!!!

!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!

!!!!

!!!!

!!

!!!!

!!!!!!!!!!!!!!

!!

!!!!!!!!!

!!!!!!!!!!!!!!!

!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!

!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!

!

!!!!

!

!!

!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!

!

!!

!

!!!!

!!

!!

!

!!

!!!

!!!!

!!!!

!!

!!!!

!!!

!!!!!!!!!!!

!!!!!!

!!!!

!!!!

!!!

!!!!

!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!

!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!

!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!

!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!

!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!

!!!!

!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!

!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!

!!!!!!!

!!!!!!!!!!!!!!

!!!!!!!!!!!!!!

!!

!!

!!!

!!

!!

!

!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!

!!!!!!

!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!

!!!!!!!!!!!!!!!!!!!!!!!

!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!

!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!

!

!!!!

!!!

!!!!

!!

!

!!!!!!!!!!!!!!!!!!!!!!!!!!!!!

!!!!

!!

!

!!!

!!

!!

!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!

!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!

!!!!

!

!!

!

!!

!!!

!!!!

!

!!

!!!!!!!!!!!

!!!

!!!!

!!

!!!

!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!

!!!!

!

!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!

!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!

!!

!!!!

!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!

!!

!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!

!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!

!!

!!

!!!

!!!!!!!!!!!!!!!!!!!!!!!!!!

!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!

!!

!!

!

!!

!!!!!

!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!

!

!!

!!!

!!

!!

!!!!

!

!!!!!!!!!!

!!!!!!

!!!!!!!!!!

!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!

!!!!!!

!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!

!!

!!!!!!!!!!!

!!

!!!

!!

!!!!!!!!!!!!!!!!!!!

!!!

!!

!

!!

!!

!

!!!!

!

!!

!!

!!!

!!

!!!

!!

!!!

!!

!!!!!!!

!!!!!!

!!!!!!!

!

!!

!!

!

!!

!!

!

!!!

!!

!!

!

!!!!

!!!

!!

!!

!

!!!!

!!!!!!

!!!

!!!!

!!!!!!

!!!!!

!!!!

!!!!

!!!!

!!!

!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!

!

!!

!!!!

!!!

!!

!

!!

!!

!

!!

!

!!!

!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!

!!!!

!!!

!!

!!!!

!

!!!!

!!!

!!!!

!!!!

!!!!

!

!!!!

!

!!

!!!

!!!!

!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!

!!!!!!

!

!!!!!!

!!!!!

!!

!!!

!!!!

!!!!!!

!!!

!!

!!

!

!!!!

!

!!

!!!!

!

!!!!

!!!

!!!!!!

!!!!

!!!

!!

!

!!!!!!!

!!!

!!

!!

!

!!

!

!!

!!!

!!

!!!!

!!

!!!

!!

!

!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!

!!

!

!!

!!

!

!!

!!!!

!!!!!!!!!!

!!!!!!^_Irish Hillsstudy areaDCPPstudy areaPrice Canyonstudy areaPointBuchonPoint San Luis S T 1 S T 1 S T41 S T58 S T227£101AvilaBeachEdnaGardenFarmsLos OsosMorro BayPismo BeachPort SanLuisSan LuisObispoSantaMargaritaThyleDCPP-120°37'-120°37'-120°44'-120°44'-120°51'-120°51'35°25'35°25'35°18'35°18'35°11'35°11'Locations of Hand Samples

^_Arroyo GrandeSanta BarbaraDCPPDCPP GEOLOGIC MAPPING PROJECTPacific Gas and Electric CompanyFigure extent

+/-0 2 4mi.0 4 8kmEXPLANATIONSample location

!2011 Vibroseis line2011 AWD line and 2011 Vibroseis line2011 AWD lineSeismic Reflection Survey1:175,000NAD 83 / UTM Zone 10N,Map projection and scale:C-1Figure!!!!!!!!!!!!!!!!!!!!!

!!!!!!!!!!!!!!!!!!!!!

!!!!!!!2012 high-resolution survey receiver array2011 nodal receiver array!!!!!!!!!!!!!!!!!!!!!

!!!!!!!!!!!!!!!!!!!!!

!!!!!!!2011 nodal receivers, no shotpoints Page D1 of 10 GEO. DCPP.TR.14.01, Rev. 0 APPENDIX D: GIS FILES AND LAYERS (ELECTRONIC APPENDIX)

SUMMARY

Appendix D consists of electronic files and this document summarizing the GIS data. The electronic GIS files are those used to make the geologic maps for the Irish Hills study area (Plate 1), Diablo Canyon Power Plant (D CPP) study area (Plate 2) and Price Canyon study area (Figure 3-9). This document descri bes the GIS files and GIS layers used to create the three maps. We first describe the GIS files and then the GIS layers.

GIS File Descriptions The electronic portion of Appendix D includes ArcGIS map document files (*.mxd),

shapefiles (*.shp), geodatabase files (*.gdb), and georeference d raster files (*.tif and

  • .jp2) used to display all data presented on the geologic maps of the three study areas (Plate 1, Plate 2, and Figure 3-9). Shapefiles, geodatabase files, and georeferenced raster files are defined in the North American Datum 1983 (NAD 83) UTM Zone 10N coordinate system. Metadata were generate d for each file and include the following descriptions: data type data source purpose of the data time and date of data creation creator of the data the standards used to create th e data, including data projection The map document files and the relevant study area are listed in Table D-1: Table D-1. ArcGIS Map Document Files File Name Study Area (and Plate or Figure Number) GMP_GIS_Package_Plate_1.mxd Irish Hills (Plate 1) GMP_GIS_Package_Plate_2.mxd DCPP (Plate 2)

Figure_03-9.mxd Price Canyon (Figure 3-9)

The shapefiles, geodatabase files, and raster f iles used to create Plates 1 and 2 and Figure 3-9 can be grouped into files and files. Tables listing these files are on the subsequent pages.

Page D2 of 10 GEO. DCPP.TR.14.01, Rev. 0 Table D-2 lists the geology files, a summary of their contents, and th e study area geologic maps that use the geology files. These files are the primary focus of the GMP. Table D-2. Geology Shapefiles and Geodatabase Files Used to Create the

Geologic Maps File Name Description Area of Relevance Wells_GMP.shp Point shapefile containing locations and information for deep oil and hydrogeologic wells in the study areas; Discussed in Appendix E Plate 1 and Figure 3-9 Geology_Compilation_

GMP.shp Polygon shapefile of geologic units Plates 1 and 2 and Figure 3-9 Geology_Compilation_ Contacts_GMP.shp Polygon shapefile of geologic units according to the stratigraphy used on Plate 1 and Figure 3-9 Plate 1 and Figure 3-9 DCPP_Site_Map_Contacts_

GMP.shp Line shapefile of geologic contacts for

Plate 2 Plate 2 Geology_Compilation_Anno_

24k_GMP.gdb Annotation geodatabase file to label geologic units on Plate 1 and Figure 3-9 Plate 1 and Figure 3-9 Geology_DCPP_Site_Anno_

3k_GMP.gdb Annotation geodatabase file to label geologic units on Plate 2 Plate 2 Fault_Fold_Compilation_

GMP.shp Line shapefile of faults, folds, and lineaments Plates 1 and 2 and Figure 3-9 Strike_Dip_Compilation_

GMP.shp Point shapefile of bedding attitudes and outcrop-scale faults compiled from various sources Plates 1 and 2 and Figure 3-9 Strike_Dip_Field_GMP.shp Point shapefile with field records from GMP, including bedding attitudes, photograph and sample locations, and outcrop-scale faults, shears, and folds Plates 1 and 2

Page D3 of 10 GEO. DCPP.TR.14.01, Rev. 0 Table D-3 lists the geography files, a summa ry of their contents, and the study area geologic maps that use the files. Files from sources other than the GMP are indicated and are not included in the digital database. Th e non-GMP sources are listed in the footnotes below the table. Table D-3. Geography Shapefiles, Geodatabase File, and Raster Files Used to

Create the Geologic Maps File Name Description Area of Relevance Extent_of_Plates.shp Polygon shapefile showing extents of Plates 1 and 2 Plates 1 and 2 (inset maps)

Index_map.tif Raster image of the DCPP-vicinity geography Plates 1 and 2 and Figure 3-9 (inset maps)

DCPP_Site.shp Point shapefile with the location of DCPP Plate 1 and Figure 3-9 inset

map Study_Area_Boundary.shp Polygon shapefile showing extent of Irish Hills study area Plate 1 Coastline_from_CA_Coastal

_LiDAR.shp Line shapefile showing approximate low tide line along coast Plates 1 and 2 Study_Area_Location_

Names.shp Point shapefile with names of key geographic locations Plates 1 and 2 Roads.shp Line shapefile with DCPP roads Plate 2 Buildings.shp Polygon shapefile with DCPP buildings Plate 2 Composite_HS_2013_07_

UTM_NAD83_1m_315deg .jp2 Raster hillshade image created from 1 m composite lidar-MBES DEM; artificial sun azimuth 315°, inclination 45° Plates 1 and 2 and Figure 3-9 Composite_DEM_2013_

07_UTM_NAD83_contours .gdb Geodatabase containing 10 m and 100 m contours generated from 1 m composite lidar-MBES DEM (not shown on any figures) Laguna_Lake.shp f Polygon shapefile showing extent of Laguna Lake Plate 1 City_Points.shp Point shapefile with names of local cities

and towns Plate 1 and Figure 3-9 Major_Highways.shp ff Line shapefile showing major roadways Plate 1 f City of San Luis Obispo GIS file obtained from the SLO DataFinder website (http://lib.calpoly.edu/gis/).

ff From ESRI Data and Maps and StreetMap North America for ArcGIS 10.2 Basemap Database (DVD set provided by ESRI that accompanies ArcGIS licenses).

Page D4 of 10 GEO. DCPP.TR.14.01, Rev. 0 GIS Layer Descriptions Each map document file (*.mxd) consists of a series of layers. The layers are manipulations of the shapefiles, geodatabase files, and raster files to display selected information seen on the geologic maps. For each layer, a Layer Properties window shows information about the layer including the scale, source data, symbology, labels, and a definition query that can be used to filter the source data. The following subsections briefly discuss the layers within each study area geologic map, but we note that much of this information can be obtained w ithin the Layer Properties window. IRISH HILLS STUDY AREA (PLATE 1) Map document file name: GMP_GIS_Package_Plate_1.mxd.

Brief descriptions of each layer included in the Plate 1 map document file are listed below. Layers for the Inset:  : Shows the extent of Plate 2 on the Plate 1 inset map. Uses the polygon shapefile Extent_of_Plates.shp. No transparency, special symbology, or label used. Definition query, "Name" = 'Extent of Plate 2', used.  : Shows simple geography of the DCPP vicinity for geographic reference on the Plate 1 inset map. Uses Index_map.tif.

Layers for the Main Map:  : Shows the location of the DCPP site. It was created for the purposes of GIS projects and map figures for scales approximately 1:

12,000 and smaller. The layer uses DCPP_Site.shp. No transparency, special symbology, definition query, or label used.

This annotation geodatabase includes geologic map symbols and lead lines to accompany Plate 1 and Figure 3-9. Uses geodatabase file Annotation_24K.gdb. No transparency, de finition query, or label used.
Shows the location of oil and hydrogeologic wells considered for the GMP for geologic information and/or considered for seismic-reflection data processing for sonic log information.

The layer uses the point shapefile Wells_GMP.shp. Layer symbology differentiates on "WELL_TYPE" attribute field between oil and gas wells (red) and hydrogeologic boreholes/well (blue).

Layer is labeled based on "WELL_NAME" attribute field. No transparency or definition query used.

Shows the location of Laguna Lake, based on the polygon shapefile Laguna_Lake.shp. The shapefile was downloaded by LCI from the Cal

Poly SLO DataFinder website. No transparency, special symbology, definition query, or label used.

Shows the total area of the GMP. Uses polygon shapefile Study_Area_Boundary.shp. It contains two non-adjoining polygons: a larger one for the Irish Hills study area and a sma ller one for the Price Canyon study area.

Page D5 of 10 GEO. DCPP.TR.14.01, Rev. 0 The DCPP study area is located entirely w ithin the Irish Hill s study area and its boundary is defined in a separate sh apefile (Extent_of_Plates.shp). No transparency, special symbology, definition query, or label used.

This group layer contains the following 7 layers:  : This layer is unselecte d for the Plate 1 display, but when selected will show locations of field stations recorded by GMP geologists. Layer source is Strike_Dip_Field_GMP.shp.  : Shows bedrock structural measurements (bedding attitudes, local faults) collected during 2012 and 2013 GMP field mapping. The layer uses the point shap efile Strike_Dip_Field_GMP.shp. No transparency is used. The layer is symbolized on the attribute field "Type." Symbology is based on USGS map standards and comes from the style file, "FGDC_CGS_20100414.style." GMP field measurements are distinguished from previously-compiled structural attitudes by the white halo that outlines each attitude and associated la bel. A definition query with a "Yes" in the "Display" attribute field selects the subset of measurements that can be displayed on Plate 1 without obscuring information due to ove rcrowding. The layer is labeled by the attribute field "Dip_Plunge."  : Shows bedrock structural measurements (bedding attitudes, local faults) compiled from existing data sets for the GMP. The layer

uses the point shapefile Strike_Dip_Compilation_GMP.shp. No transparency is used. The layer is symbolized on the attribute field "Type." Symbology is based on USGS map standards and comes from the style file, "FGDC_CGS_20100414.style." Compiled measurements are distinguished from GMP field structural attitudes by the black symbol lacking a white halo. A definition query with a "yes" in the "Disp_Reg" attribute field selects the subset of measurements that can be displayed on Plate 1 without obscuring information due to overcrowding and, to a lesser degree, conceals potentially spurious measurements. The layer is labeled by the attribute field "dip."  : Shows bedrock structural data (faults, lineaments, and fold axes). Data are from the integration of compiled map data and new information collected during GMP field mapping. The layer uses the line shapefile Fault_Fold_Compilation_GMP.shp. No transparency is used. The layer is symbolized on the "Type," "Certainty," and "Cartography" attribute fields. Symbology is based on USGS map standards and comes from the style file, "FGDC_CGS_20100414.style." A definition query of "Disp_Reg" = 'Yes' ensures that the subset of folds and faults intended for display on Plate 1 (at 1:32,000 scale) are shown. There are no labels associated with this layer. This layer includes a generalized depiction of the Los Osos fault zone and modifications to inferred traces of the San Luis Bay fault zone that are shown as thicker black

lines.  : Shows geologic unit boundaries according to the compilation geologic ma p stratigraphy used on Plate 1. Geology unit polygons from the shapefile Geology_Compilation_GMP.shp were merged based on a 'compilation unit' attribute fi eld in order to create the contacts Page D6 of 10 GEO. DCPP.TR.14.01, Rev. 0 shapefile Geology_Compilation_Contacts_GMP.shp used by this layer. The layer does not distinguish between types of geologic unit boundaries (e.g., depositional contacts vs. fault contacts; well-located vs. approximately located). No transparency, special symbology, definition query, or label used (unit labels are displayed through an annotation geodatabase).  : Shows the approximate low tide line as a white line. The layer uses the line shapefile Coastline_from_CA_Coastal_LiDAR.shp. No transparency, special symbology, definition query, or label used.  : Shows colored geologic unit polygons compiled and updated for the GMP. The la yer uses the polygon shapefile Geology_Compilation_GMP.shp. Transparency is set to 50% for Plate 1. The layer is symbolized using the "Comp_unit" attribute field. There are no definition queries or labels for this layer. Unit labels are displayed with an annotation geodatabase.  : This group layer contains the following three layers:  : Shows the locations and names of prominent points along the coast on Plate 1. Th e layer uses the point shapefile Study_Area_Location_Names.shp. No transparency, special symbology, or

definition query, used. Layer is labele d using the "NAME" attribute field.  : Shows the locations and names of cities and communities on Plate 1.

The layer uses the point shapefile City_P oints.shp. No transparency or special symbology is used. A definition query is used to filter out some additional names in the shapefile that were considered unnecessary. Layer is labeled using the "NAME" attribute field.  : Shows selected roadways on Plate 1. The layer uses the line shapefile Major_Highways.shp, provided by ESRI. No transparency or special symbology is used. A definition query on the attribute field "FID" is used to filter only essential roadways that are needed for map clarity. Layer is labeled using the "HWY_SYMBOL" attribute field.

This group layer contains the following two layers:  : Shows topographic contours with 100 m contour intervals. The la yer uses the geodatabase Contours_2013_07_UTM_NAD83_10m.gdb. The layer is turned off for Plate 1, but is included as an additional resource for the GMP or other PG&E-related

projects. A definition query "Type" = '100s' is set for showing contours on the Plate 1 map or maps of similar scale. 10 m contours are also available in the geodatabase file.  : Shows a hillshade image from a composite onshore-offshore 1m DEM. The hillshade has an artificial sunlight azimuth of 315 degrees and an inclination of 45 degrees. A 50% transparency is used for Plate 1.

[End of layers for Plate 1]

Page D7 of 10 GEO. DCPP.TR.14.01, Rev. 0 DCPP STUDY AREA (PLATE 2) Map document file name: GMP_GIS_Package_Plate_2.mxd.

Brief descriptions of each layer included in the Plate 2 map document file are listed below. Layers for the Inset:  : Shows the extent of Plates 1 and 2 on the Plate 2 inset map.

Uses the polygon shapefile Extent_of_Pl ates.shp. No transparency, special symbology, definition query, or label used.  : Shows simple geography of the DCPP vicinity for geographic reference on the Plate 2 inset map. Uses Index_map.tif.

Layers for the Main Map:

This annotation geodatabase includes geologic map symbols and lead lines to accompany Plate 2. Uses geodatabase file "Geology_DCPP_Site_Anno_3k.gdb." No transpar ency, definition query, or label used.  : This layer is unselecte d for the Plate 2 display, but when selected will show locations of field stations recorded by GMP geologists. Layer source is Strike_Dip_Field_GMP.shp.  : Shows bedrock structural measurements (bedding attitudes, local faults) collected during 2012 and 2013 GMP field mapping. The layer uses the point shap efile Strike_Dip_Field_GMP.shp. No transparency is used. The layer is symbolized on the attribute field "Type." Symbology is based on USGS map standards and comes from the style file, "FGDC_CGS_20100414.style." GMP field measurements are distinguished from previously-compiled structural attitudes by the white halo that outlines each attitude and associated la bel. A definition query with a "Yes" in the "Display" attribute field selects the subset of measurements that can be displayed on Plate 2 without obscuring information due to ove rcrowding. The layer is labeled by the attribute field "Dip_Plunge."  : Shows bedrock structural measurements (bedding attitudes, local faults) compiled from existing data sets for the GMP. The layer

uses the point shapefile Strike_Dip_Compilation_GMP.shp. No transparency is used. The layer is symbolized on the attribute field "Type." Symbology is based on USGS map standards and comes from the style file, "FGDC_CGS_20100414.style." Compiled measurements are distinguished from GMP field structural attitudes by the black symbol lacking a white halo. A definition query with a "yes" in the "Disp_D tl" attribute field se lects the subset of measurements that can be displayed on Plate 2 without obscuring information due

to overcrowding and, to a lesser degr ee, conceal potentially spurious measurements. The layer is labeled by the attribute field "dip."  : Shows bedrock structural data (faults, lineaments, and fold axes). Data are from the integration of compiled map data Page D8 of 10 GEO. DCPP.TR.14.01, Rev. 0 and new information collected during GMP field mapping. The layer uses the line shapefile Fault_Fold_Compilation_GMP.shp. No transparency is used. The layer is symbolized on the "Type," "Certainty," and "Cartography" attribute fields. Symbology is based on USGS map standards and comes from the style file, "FGDC_CGS_20100414.style." A definition query of "Disp_Dtl" = 'Yes' ensures that the subset of folds and faults inte nded for display on Plate 2 (at 1:3,000 scale) are shown. There are no labels associated with this layer.  : Shows unit contacts according to the DCPP geologic map stratigraphy used on Plate 2. Uses the line shapefile DCPP_Site_Map_Contacts_GMP.shp. No transparency is used. The layer is symbolized on the "Type," "Certainty,"

and "Cartography" attribute fields. Symbology is based on USGS map standards and comes from the style file, "FGDC_CGS_20100414.style." No definition queries or labels are used.  : Shows the approximate low tide line as a white line. The layer uses the line shapefile Coastline_from_CA_Coastal_LiDAR.shp. No transparency, special symbology, definition query, or label used.  : Shows colored geologic unit polygons compiled and updated for the GMP within the DCPP study area. Uses the polygon shapefile Geology_Compilation_GMP.shp. Transparency is set to 50% for Plate 2. The layer is symbolized using the "Dtl_unit" attribute field. Th ere are no definition queries or labels for this layer. Unit labels are displayed with an annotation

geodatabase.

This group layer contains the following two layers:
Shows roads within the DCPP study area by TetraTech, Inc. (2010) based on lidar data. The roads have not been reviewed by DCPP for accuracy or completeness. Uses the line shapefile Roads.shp. No transparency, special symbology, definition query, or label used.  : Shows buildings within the DCPP study area that were identified by TetraTech, Inc. (2010) based on interpretation of lidar data. The buildings have not been reviewed by DCPP for accuracy or completeness. Uses the polygon

shapefile Buildings.shp. No transparency, special symbology, or label used. A definition query of "Area_sq_m" > 33 was used to remove very small structures from Plate 2.

this group layer contains the following two layers:  : Shows topographic contours with 10 m contour intervals. The la yer uses the geodatabase Contours_2013_07_UTM_NAD83_10m.gdb. The layer is turned off for Plate 2, but is included as an additional resource for the GMP or other PG&E-related projects. A definition query "Type" = '10s' is set for showing contours on the Plate 2 map or maps of similar scale. 100 m contours are also available in the geodatabase file.  : Shows a hillshade image from a composite onshore-offshore 1m DEM. The hillshade has an Page D9 of 10 GEO. DCPP.TR.14.01, Rev. 0 artificial sunlight azimuth of 315 degrees and an inclination of 45 degrees. A 30% transparency is used for Plate 2.

[End of layers for Plate 2] PRICE CANYON STUDY AREA (FIGURE 3-9) Map document file name: Figure_03-9.mxd.

Brief descriptions of each layer included in the Figure 3-9 map document file are listed below. Layers for the Inset:  : Shows the location of the DCPP site in the inset map. The layer uses the point shapefile DCPP_Site.shp. No transparency, special symbology, or definition query used. Label field is "Name."  : Shows simple geography of the DCPP vicinity for geographic reference on the Plate 1 inset map. Uses Index_map.tif.

Layers for the Main Map:

Shows the location of oil and hydrogeologic wells considered for the GMP for geologic information and/or considered for seismic-reflection data processing for sonic log information.

The layer uses the point shapefile Wells_GMP.shp. Layer symbology differentiates on "WELL_TYPE" attribute field between oil and gas wells (red) and hydrogeologic boreholes/well (blue).

Layer is labeled based on "WELL_NAME" attribute field. No transparency or definition query used.  : This group layer file contains the following four layers:  : Shows bedrock structural measurements (bedding attitudes, local faults) compiled from existing data sets for the GMP. The layer

uses the point shapefile Strike_Dip_Compilation_GMP.shp. No transparency is used. The layer is symbolized on the attribute field "Type." Symbology is based on USGS map standards and comes from the style file, "FGDC_CGS_20100414.style." The layer is labe led by the attribute field "dip."  : Shows bedrock structural data (faults, lineaments, and fold axes). Data for th e Figure 3-9 study area are from compiled map data. The layer uses the line shapefile Fault_Fold_Compilation_GMP.shp. No transparency is used. The layer is symbolized on the "Type," "Certainty," and "Cartography" attribute fields. Symbology is based on USGS map standards and comes from the style file, "FGDC_CGS_20100414.style." There are no definition queries or labels associated with th is layer as applied to Figure 3-9.  : Shows geologic unit boundaries according to the compilation geologic map stratigraphy used on Figure 3-9 and Plate 1. Geology unit polygons from the shapefile "Geology_Compilation_GMP.shp" were merged based on a 'compilation unit'

attribute field in order to create the contacts shapefile Page D10 of 10 GEO. DCPP.TR.14.01, Rev. 0 Geology_Compilation_Contacts_GMP.shp used by this layer. The layer does not distinguish between types of geologic uni t boundaries (e.g., depositional contacts vs. fault contacts; well-located vs. approximately located). No transparency, special symbology, definition query, or label used (unit labels are displayed by converting labels to graphics).  : Shows colored geologic unit polygons compiled and for the GMP. The laye r uses the polygon shapefile Geology_Compilation_GMP.shp. Transparency is set to 50% for Figure 3-9. The layer is symbolized using the "Comp_unit" attribute field. There are no definition queries or labels for this layer. Unit la bels are displayed by converting labels to graphics.

This group layer contains the following one layer:  : Shows the locations and names of cities and communities on Figure 3-9. The layer uses the point shapefile City_Points.shp. No transparency or special symbology is used. A definition query is used to show the town of Edna on Figure 3-9. Layer is labeled using the "NAME" attribute field.
This group layer contains the following two layers:  : Shows topographic contours with 10 m contour intervals. The la yer uses the geodatabase Contours_2013_07_UTM_NAD83_10m.gdb. The layer is turned off for Figure 3-9, but is included as an additional resource for the GMP or other PG&E-related projects. A definition query "Type" = '10s' is set for showing contours on maps of similar scale. 100 m contours are also available in the geodatabase file.  : Shows a hillshade image from a composite onshore-offshore 1m DEM. The hillshade has an artificial sunlight azimuth of 315 degrees and an inclination of 45 degrees. A 50%

transparency is used for Figure 3-9.

[End of layers for Figure 3-9]

Page i GEO. DCPP.TR.14.01, Rev. 0 Appendix E: Stratigraphic and Geophysical Data from Historical Wells in the Irish Hills and Vicinity ABSTRACT Records of historical oil and hydr ogeologic wells provide geologic and geophysical data for understanding the subsurface stratigraphy, structure, and material properties near the Di ablo Canyon Power Plant (DCPP), San Luis Obispo County, California. Reco rds for 26 oil and gas wells and 8 hydrogeologic wells are revi ewed and summarized in this data report. The oil wells were drilled between 1928 and 2008 to depths of approximately 1,000 to 10,800 feet, and most records are on file at the Santa Maria office of the California Division of Oil, Gas, and Geothermal Resources. Additional paleontological information for the oil wells was obtained from the core repository at California State University, Bakersfield. Typical records available included a well summary report, driller's log, lithologic log, paleontology report, electric log, sonic log, and dip log. Not all record types are available for every well. S onic log data, available for 8 of the wells, were digitized to help establish the P-wave velocities of the various lithologic units at depth. The hydrogeologic wells are located in the Los Osos-Baywood Park area adjacent to Morro Bay and range in depth from approximately 500 to 750 feet. Well logs were obtained from a

groundwater report prepared by Clea th & Associates in 2003. Typical information available for the wells in cludes geologic and electronic logs.

Page ii GEO. DCPP.TR.14.01, Rev. 0 TABLE OF CONTENTS Page Abstract ......................................................................................................................

.................. i E

1.0INTRODUCTION

............................................................................................................. 1E2.0METHODS ......................................................................................................................

1E2.1Data Collection .................................................................................................... 1E2.2Evaluation of Well Location, Elevation, and Location Accuracy and Uncertainty .......................................................................................................... 4E2.3Interpretation of Stratigraphy ............................................................................... 6E2.4Construction of a Deviation Log (Honolulu-Tidewater 1 Well Only) .................... 7E2.5Digitization of the Sonic Log Data ....................................................................... 8E3.0WELL DATA SUMMARIES AND INTERPRETATION .................................................... 9E3.1API 07900174, Old See Canyon 1 ...................................................................... 9E3.2API 07900247, Maino-Gonzales 1 .................................................................... 11E3.3API 07900310, Pecho 1 .................................................................................... 14E3.4API 07900378, Mello 2 ...................................................................................... 16E3.5API 07900380, Spooner 1 ................................................................................. 17E3.6API 07900471, Bassi Core Hole 1 ..................................................................... 21E3.7API 07900477, Honolulu-Tidewater 1 ............................................................... 22E3.8API 07900478, Montadoro 1 ............................................................................. 24E3.9API 07900486, Heller Core Hole 1 .................................................................... 26E3.10API 07900550, Townsend-Gunter 1 .................................................................. 27E3.11API 07900551, Townsend-Peterson 1 .............................................................. 28E3.12API 07900581, Sousa 1 .................................................................................... 29E3.13API 07900591, Signal ETS 1 ............................................................................. 30E3.14API 07900618, Rock 75 .................................................................................... 31E3.15API 07900654, Holmes 1 .................................................................................. 32E3.16API 07900671, Tar Springs 1A .......................................................................... 34E3.17API 07920532, Leroy F-7B

................................................................................

35E3.18API 07920544, Guidetti A1 ................................................................................ 36E3.19API 07920545, Guidetti A3 ................................................................................ 36E3.20API 07920547, Guidetti A7 ................................................................................ 37E2.21API 07920566, Guidetti A4 ................................................................................ 38 Page iii GEO. DCPP.TR.14.01, Rev. 0 E3.22API 07920594, Shell Beach 1 ........................................................................... 39E3.23API 07921166, Rock 11G .................................................................................. 40E3.24API 560452001300, Offshore Well P-0435-1 .................................................... 41E3.25API 560462000100, Offshore Well P-060-1, Oceano 1 .................................... 42E3.26API 560462000500, Offshore Well P-0397-1 .................................................... 43E3.2730S/10E-13L4, CCW Pecho .............................................................................. 43E3.2830S/10E-13Na, S&T New .................................................................................. 45E3.2930S/11E-17E7, LOCSD-SB Deep ................................................................... 46E3.3030S/11E-17N10, CCW-SB #1 ......................................................................... 47E3.3130S/11E-18F2, LOCSD-Ferrell #2 .................................................................. 48E3.3230S/11E-18K8, LOCSD-10th New .................................................................. 49E3.3330S/11E-18L2, LOCSD-Palisades .................................................................. 50E3.3430S/11E-18L6, USGS-Palisades .................................................................... 51E4.0VELOCITY CHARACTERISTICS FROM SONIC LOG DATA ...................................... 52E

5.0REFERENCES

.............................................................................................................. 55ADDITIONAL SECTIONS (in Sepa rate Electronic Files) E6.0 WELL RECORDS E7.0 GIS FILES OF WELL DATA IN ArcGIS SHAPEFILE FORMAT AND TABLE IN EXCEL FORMAT E8.0 PERSONAL COMMUNICATION RECORDS E8.1 Clarence Hall, August 9, 2011 E8.2 Ross Brunetti, May 2013 E8.3 Kristin McDougall, June 2013 E9.0 DEVIATION LOG FOR HONOLULU-TIDEWATER WELL IN EXCEL FORMAT E10.0 DIGITIZED SONIC LOGS IN EXCEL FORMAT Page iv GEO. DCPP.TR.14.01, Rev. 0 LIST OF TABLES Table E2-1 Historical Oil Wells Selected for Study Table E2-2 Historical Hydrogeologic Wells Selected for Study Table E2-3 Matrix of Scenario Well Deviations (in feet) for Consideration in Well Location Uncertainty Estimates Table E3-1 to Table E3-34 Summary Interpretations of Selected Wells Table E4-1 Typical P-Wave Velocities from Sonic Log Data LIST OF FIGURES Figure E1-1 Location of Selected Wells Figure E2-1 Location of Selected Wells and 2011 Seismic Reflection Lines, Western Irish Hills Figure E2-2 Location of Selected Wells and 2011 Seismic Reflection Lines, Eastern Irish Hills and San Luis Range Figure E2-3 Location of the Maino-Gonzales 1 and Spooner 1 Wells Figure E2-4 Location of the Pecho 1 Well Figure E2-5 Location of the Honolulu-Tidewater 1 Well Figure E2-6 Location of the Montadoro 1 Well Figure E2-7 Location of the Sousa 1 Well Figure E2-8 Deviation Plots of Honolulu-Tidewater 1 Well Figure E2-9 Sonic Logs of Guidetti A3 and Guidetti A4 Wells Figure E2-10 Sonic Logs of Offs hore Wells P-0397-1 and P-0435-1 Figure E2-11 Sonic Logs of Tar Springs 1A and Shell Beach Wells Figure E2-12 Sonic Logs of Leroy F-7B and Rock 11G Wells LIST OF PLATES Plate E1 Log of the Maino-Gonzales 1 Well Plate E2 Log of the Pecho 1 Well Plate E3 Log of the Spooner 1 Well Plate E4 Log of the Honolulu-Tidewater 1 Well (2 sheets) Plate E5 Log of the Montadoro 1 Well

Page E1 of 57 GEO. DCPP.TR.14.01, Rev. 0 Appendix E: Stratigraphic and Geophysical Data from Historical Wells in the Irish Hills and Vicinity E

1.0 INTRODUCTION

Historical well data provide information on the subsurface stratigraphy and geophysical properties of rock units in the vicinity of the Diablo Canyon Power Plant (DCPP). This data report documents the review of existing well data in the Irish Hills area (Figure E1-1), where seismic-reflection survey data were collected in 2011 by Pacific Gas & Electric Company (PG&E). Hundreds of wells have been drilled in San Luis Obispo County for oil and gas exploration.

These wells, dating from as early as the 1920s an d continuing to present day, are a valuable source of information on the subsurface strata. Only a handful of prospecting wells were drilled in the Irish Hills near DCPP and near the main area of seismi c-reflection surveying. All were "dry" holes, drilled between 1927 and 1958, and focused on Tertiary rocks of the Pismo Basin. The closest producing oil field within the Pismo Ba sin is the Arroyo Grande Field located at the eastern margin of the Irish Hills, in the Price Canyon area. While the DCPP site is some distance from this field and others, many of the DCPP stratigraphic units can be traced continuously to, or have lithologic analogs in, the producing oil fields. Therefore, key wells from the oil fields and other locations farther from the seismic-reflection survey area, including three offshore wells, are reviewed in this report.

In addition to the oil wells, which have typical depths of several thousa nd feet and are up to over ten thousand feet deep, shallower hydrogeologic wells drilled for groundwater monitoring and/or supply provide useful geologic information for the interpretation of seismic-reflection data.

Several relatively deep (several hundred feet to approximately 750 feet deep) hydrogeologic wells are located in the Los Osos groundwater ba sin that includes the low-lying areas adjacent to Morro Bay. Eight wells located in the direct vicinity of seismic-reflection profile lines collected by PG&E in 2011 provide geologic data constrains fo r the project and are incl uded in this report.

This well data report was prepared for the Ge ologic Mapping Project by Dr. Janet Sowers of Fugro Consultants, Inc. (FCL), with contributions from Dr. Stephen Thompson and Mr. Brian Gray of Lettis Consultants International, Inc. (LCI).

E2.0 METHODS The approach of this study was to collect, pl ot, and analyze geologic and geophysical well log data relevant to the recently completed seismic-reflection surveys. Tasks included data collection, interpretation of stratigraphy, assessment of well locati on and elevation accuracy and uncertainty, construction of a deviation log (f or the Honolulu-Tidewate r 1 well only), and the digitization of sonic log data. These methods are described in Sections E2.1 to E2.5 below. E2.1 Data Collection Both onshore and offshore well data were collected. Wells were selected for study on the basis of their proximity to the Irish Hills seismic-reflection survey area and the availability of Page E2 of 57 GEO. DCPP.TR.14.01, Rev. 0 stratigraphic information and/or sonic log data (Figure E1-1). All oil well records are compiled and provided separately in electronic format in (e lectronic) Section E6.0. Onshore oil well information is summarized in a database maintained by the California Department of Oil, Gas, and Geothermal Resources (DOGGR), based on records collected for each oil well as required by the state. The well database is available online at http://maps.conservation.ca.gov/doms/doms-app.html. These summary well data, in Excel and ArcGIS shapefile format (February 2011 update), were downloaded and used as a primary source of information. The DOGGR records typically in clude detailed well history, core records, lithologic logs, and geophysical logs. Scans of these files were obtained for each well from either the DOGGR or the U.S. Geological Survey (U SGS). The USGS had collected a number of detailed well records for internal research purposes (e.g., Sweetkind et al., 2010) and provided these records to PG&E by CD (V. Langenheim, USGS, pers. comm., 2010).

Additional data for onshore oil wells were obtained by various means. A commercial service operated by TGS-NOPEC called LOG-LINE Plus! pr ovides for purchase printed copies of well logs they have collected. We obtained sonic l ogs for five onshore wells from this service by ordering them from the website at http://www.tgsnopec.com/data.aspx. Additional records for the Honolulu-Tidewater 1 well, not included in the DOGGR or USGS files, were provided by Chevron-Texaco (L. Knauer, Chevron, pers. comm., 2013). Paleontology reports accompanying some of the wells (Maino-Gonzales 1, Pecho 1, and Spooner 1) were purchased online from the California Well Sample Repository collection at California State University, Bakersfield (CSUB). Of particular note is the unsuccessful search for sonic log data for the Honolulu-Tidewater 1 well. The history file for that well indicates sonic logs were collected for the lower portion of the well. However, no logs were found through our search with the DOGGR, the commercial LOG-LINE Plus! service, with the CSUB Well Repos itory, or with the curr ent owner of the well (Chevron-Texaco).

Offshore well data were obtained from published literature primaril

y. Logs of offshore wells in the vicinity of the DCPP were provided in Willingham et al. (2013, Plate 3) and Hall (1982).

Three offshore wells were selected for study, primarily to provide P-wave velocity information on the offshore units. Information for Oceano well P-060-1 was obtained from Hall (1982), McCullough (1987), and Miller and Meltzer (1999). Additional information on the offshore wells, including API numbers, measured depths, and well owner information, was taken from the database maintained by the federal Bureau of Ocean Energy Management (BOEM), which was downloaded in ArcGIS shapefile format (May 29, 2012, update; file "Pacific Wells.zip" downloaded 7/24/2013 from www.boem.gov/Oil-and-Gas-Energy-Program/Mapping-and-Data/Pacific.aspx

). Information from hydrogeologic wells in the Los Osos-Baywood Park area adjacent to Morro Bay was evaluated and compiled from a 2003 report by Cleath & A ssociates, "Geologic Structure of the Los Osos Valley Ground Water Basin" that was provided to PG&E by Tim Cleath of Cleath-Harris Geologists, Inc. (personal communication, 2011). The main report and appendix materials include maps of well locations, well summary information, geologic logs, and scans of electronic logs (referred to herein as "e-logs"). Information provided for a few Page E3 of 57 GEO. DCPP.TR.14.01, Rev. 0 of the wells was incomplete (e.g., there is no i ndication of the year dr illed for wells 30S/11E-17E7 or 30S/11E-18K8). Available data were collected, compiled, and analyzed for 26 historical oil wells and 8 hydrogeologic wells. Table E2-1 lists the oil we lls by API. Table E2-2 lists the hydrogeologic wells by the California state well number per Cleath & Associates (2003). Of the 34 well records selected, 18 are located on or adjacent to seismic-reflection profile lines collected in 2011, and 8 include sonic log data (including 3 offshore oil wells) (Tables E2-1 and E2-2). The locations of the 34 wells are shown on Figures E1-1, E2-1, an d E2-2. Those with sonic logs are shown in yellow. Figures E2-1 and E2-2 also show the locations of the 2011 seismic survey lines. Table E2-1. Historical Oil Wells Selected for Study

  1. API Number Name Adjacent to Seismic Line? Sonic Log? Total depth (feet) 1 079-00174 See Canyon 1 No No 2,545 2 079-00247* Maino-Gonzales 1 Yes No 1,575 3 079-00310* Pecho 1 Yes No 2,745 4 079-00378 Mello 2 Yes No 1,505 5 079-00380* Spooner 1 Yes No 1,749 6 079-00471 Bassi Core Hole 1 No No 959 7 079-00477* Honolulu-Tidewater 1 Yes No 10,788 8 079-00478* Montadoro 1 Yes No 6,146 9 079-00486 Heller Core Hole 1 No No 1,305 10 079-00550 Townsend-Gunter 1 No No 3,286 11 079-00551 Townsend-Peterson 1 No No 1,445 12 079-00581 Sousa 1 Yes No 1,233 13 079-00591 Signal ETS 1 Yes No 1,168 14 079-00618 Rock 75 Yes No 2,200 15 079-00654 Holmes 1 No No 3,935 16 079-00671 Tar Springs 1A No Yes 3,744 17 079-20532 Leroy F-7B No Yes 7,310 18 079-20544 Guidetti A1 No No 3,050 19 079-20545 Guidetti A3 No Yes 3,050 20 079-20547 Guidetti A7 No No 2,751 21 079-20566 Guidetti A4 No Yes 3,000 22 079-20594 Shell Beach 1 No Yes 5,547 23 079-21166 Rock 11G Yes Yes 2,005 Page E4 of 57 GEO. DCPP.TR.14.01, Rev. 0
  1. API Number Name Adjacent to Seismic Line? Sonic Log? Total depth (feet) 24 560452001300 P-0435-1 No Yes 6,900 25 560462000100 P-060-1, Oceano 1 No No 8,020 26 560462000500 P-0397-1 No Yes 3,666
  • Well log details presented on Plates E1 through E5.

Table E2-2. Historical Hydrogeologic Wells Selected for Study # State Well Number 1 Name Adjacent to Seismic Line? Sonic Log? Total depth (feet) 1 30S/10E-13L4 CCW Pecho Yes No 675 2 30S/10E-13Na S&T New Yes No 500 3 30S/11E-17E7 LOCSD-SB deep Yes No 560 4 30S/11E-17N10 CCW-SB#1 Yes No 750 5 30S/11E-18F2 LOCSD-Ferrell #2 Yes No 645 6 30S/11E-18K8 LOCSD-10 th New Yes No 650 7 30S/11E-18L2 LOCSD-Palisades Yes No 612 8 30S/11E-18L6 USGS-Palisades Yes No 620 1 From Cleath & Associates (2003).

Five historical oil wells drilled in the Irish Hills in close proximity to the 2011 seismic reflection lines (Figure E2-1) are of special interest. Available well log data for these five wells were assembled on oversized plates (Pla tes E1 through E5) to better unde rstand the natu re and quality of the data and interpretations in these locations. Each plate shows, plo tted side-by-side versus depth, all log data available for the well, which may include a lithologic log, e-log, dip log, paleontological information, and various stratigra phic interpretations. Th ese five wells were drilled from 1927 to 1958. Data for these wells are of varying quality and completeness, and lack some information contained in modern geologic and geophysical logging.

No sonic logs were encountered for these wells. E2.2 Evaluation of Well Location, Elevation, and Location Accuracy and Uncertainty Available well location and elevation information was evaluated to improve accuracy where possible and to estimate the uncertainty in these data for each well. For onshore oil wells, location and elevation information is listed in the DOGGR database, which is primarily based on the locations described in the well reco rds. According to Ross Brunetti, DOGGR Page E5 of 57 GEO. DCPP.TR.14.01, Rev. 0 geologist/petroleum engineer in Orcutt, California), the well locations in the DOGGR database were digitized from points that had been hand-plotted using the location information in the well record on a map at a scale of 1 inch = 1 mile (R. Brunetti, pers. comm., 2013). Given this method, the points in the database are expected to be approximate locations only, and location information provided in the original well record should be considered more precise than the digitized points created by DOGGR. Most well records report locati on with respect to the Public Lands Survey (PLS) system.

The onshore oil well locations discussed in this report and provided in ArcGIS shapefile format in electronic Section E7.0 were compiled by the following methods: Observation in the field by GMP geologist s at two onshore oil wells (Spooner 1 and Honolulu-Tidewater 1). Study of the onshore oil well history records and plotting of PLS locations in ArcGIS based on information provided in the well records. Acceptance of the locations provided in the DOGGR database (most typical for wells not located directly on or adjacent to seismic-reflection lines). Consideration of well locations marked on USGS topographic sh eets and on geologic maps (e.g., Hall, 1973a).

Initial locations of the offshore wells were taken from digitized figures and plates in Willingham et al. (2013). Revised and reported locations of the offshore wells, along with API numbers, measured depths, and well owner information, we re taken from the BOEM database ArcGIS shapefile). As the well names reported in Willingham et al. (2013) and other literature were not present in the BOEM database, the correct wells were identified based on the approximate location and well depth.

The hydrogeologic well locations ar e digitized from Figures 1 a nd 2 in Cleath & Associates (2003).

Onshore well elevations are provided in the DOGGR database and commonly in the well history files. Well elevations are also estimated ba sed on the well locations and an onshore-offshore digital elevation model (DEM) compiled for the DCPP region by PG&E. Within the Irish Hills study area, this DEM is mostly based on on-la nd LiDAR surveys flown for PG&E in 2010 and 2011 and multibeam bathymetric surveys acquired by the state of California and PG&E for the continental shelf. Outside the area of LiDAR coverage, on-land data are derived from the regional 30-meter (m) elevation data provided by the U.S. Geological Survey. In the offshore areas beyond the multibeam survey, the study regi on DEM is based on a southern California bathymetry data set.

The best-estimate ground surface elevations for the wells provided in the GIS shapefile (see electronic Section E7.0) are based on the DEM-derived elevations corresponding to the best-estimate well coordinates. The best-estimate top-of-well elevations provided in the GIS shapefile are based on the ground surface elevation plus an offset that represents the distance between the ground surface and the zero depth point for the well log (commonly at the Kelly bushing, or KB). Offsets between the ground surface and the top of the well log are either provided in the well history file or are estimated. If no offset was encountered in the history file, a default offset Page E6 of 57 GEO. DCPP.TR.14.01, Rev. 0 of 5 feet was assumed for the onshore oil wells, and a zero offset was assumed for offshore oil wells and hydrogeologic wells. Accuracy of the well locations and elevations varies considerably. For the key wells located adjacent to seismic-reflection lines, the location accuracy and uncertainty is discussed in Section E3. E2.3 Interpretation of Stratigraphy Geologic information was reviewed for each well and stratigraphic interpretations were made based on the available data. Lithologic and stratigraphic information typically were recorded in the field by geologists who described the material (cuttings, core, or sidewall core samples), as drilling proceeded. The descriptions are recorded on either a mud log, core log, or lithologic log. The geologist may or may not have written down an interpretation of formation contacts. If formation contacts were not writte n on the original logs, we interpreted the formation contacts based on the lithologic and geophysical properties of the rock, and our stratigraphic understanding. This understanding is based primarily on the geologic mapping and stratigraphic descriptions of Hall (1973a, 1973b), William Lettis & Associates, Inc. (WLA, 2001), several papers published in the U.S. Geological Survey Bulletin 1995 series (e.g., Keller et al., 1996; Schneider and Fisher, 1996; Schwalbach and Bohacs, 1996; Cole and Stanley, 1998), and work performed for the GMP (i.e., this study). Discussion of the stratigraphic interpretation is included in the descriptions for each individual well presented in Section E3. It is important to note the e volution of the stratigraphic framework for the Pismo Basin when evaluating stratigraphic calls by well geologists. Mapping in the Pismo Basin by Hall (1973a, 1973b) established a Neogene stratigraphic sequence that differentiated middle to upper Miocene Monterey Formation from upper Miocene to Pliocene Pismo Formation based on a recognized unconformity and interfingering in the lower Pismo Formation between a deep-water facies (Miguelito Member) and a shallower water facies (Edna Member). The geologic map produced for the GMP follows the stratigraphic framew ork of Hall (1973a, 1973b). Prior to Hall's mapping, which includes the time period of all onshore oil wells drilled in the Irish Hills area, the deep-water Miguelito Member was mapped as Monterey Formation because they are lithologically similar. Regional stratigraphic frameworks continue to group the lower Pismo Formation within the "upper Monterey Formation" (e.g., Dibblee, 2004, 2006a, 2006b, 2006c).

Thus, formation calls of "Monterey Formation" by geologists in the well records are considered candidates for the Monterey Formation or the Miguelito Member of the Pismo Formation for this study. Previous workers have made stratigraphic interpretations of these wells, and a comparison of these interpretations shows there is considerable uncertainty in the formations encountered in the wells and locations of the formation contacts. A compilation of approximately 300 well logs and an interpretation of the subsurface stratigraphy were published by Hall (1982). The publication includes a tabulation of the depths of stratigraphic contacts in these wells, as well as subcrop and structure contour maps of the pre-Miocene basement surface. The stratigraphic contacts are based on Hall's interpretation of the available well log data and unders tanding of the geologic structure. Nine of the wells in terpreted by Hall (1982) ar e also interpreted here. Clarification of the stratigraphic interpretation for four of the wells was requested from Clarence Hall of the Page E7 of 57 GEO. DCPP.TR.14.01, Rev. 0 University of California, Los Angeles, who responded in a letter transmitted via e-mail dated August 9, 2011 (see electronic Section E8.1).

Sweetkind et al. (2010) published a digital compilation of approximately 600 wells in the Santa Maria Basin area. Fourteen of these are among the wells compiled here. They tabulate the depth in feet of the top of major stratigraphic units encountered in each well. Telephone interviews and e-mail exchanges we re conducted with Ross Brunetti of the DOGGR and Kristin McDougall of the U.S. Geological Survey, to help impr ove the technical basis for the stratigraphic interpretations (see electronic Section E8.0). Mr. Brunetti is a geologist with many years of experience interacting with the oil and gas industry in San Luis Obispo County. His interpretations and reasoning based on recent phone conversations (see electronic Section E8.2), are incorporated into the well descriptions in Section E3 a nd on Plates E1 through E5. Dr.

McDougall is a paleontologist with expertise in the biostratigraphy of Tertiary formations in coastal California. She provided information that helped with the interpretation of the paleontological data and is in corporated into the interpre tation of well stratigraphy. See electronic Section E8.3 for interview notes. The preferred and alternative stratigraphic interpretations for each well are presented in Section E3. Where differences exist between previous stratigraphic interpretations and this report, a discussion is provided. E2.4 Construction of a Deviation Log (Honolulu-Tidewater 1 Well Only)

A deviation log provides a record of the change in inclination (deviation from vertical) of a well with depth. Drift of the well hole from vertical is common in drilling even when not intended due to rock heterogeneities. Among the key wells that are located along or adjacent to seismic-reflection profiles, only the Honol ulu-Tidewater 1 well had records from which a deviation log could be constructed. None of the key wells along or adjacent to seismi c-reflection profiles had summary tables of well hole drift included within the well history reports.

Records of borehole azimuth and inclination fo r the Honolulu-Tidewater 1 well were recorded on a dipmeter log obtained by Chevron-Texaco (L. Knauer, Chevron, pers. comm.; see electronic Section E6.0). For each dip entry on the dipmeter log there are reported drift azimuth (in degrees) and drift angle (in degrees-minutes). From these records, we constructed a log of

downhole drift with columns for hole easting, northing, and elevation in Excel. Plots of depth (in feet) versus drift azimuth (in degrees), depth (in feet) versus drift angle (in degrees), and depth (in feet) vers us east and north drift (in feet) are presented on Figure E2-8.

The Excel file is included in electronic Section E9.0. The result suggests that, from the top of the we ll to the bottom, the hole had a net drift of approximately 220 feet (67 m) east, 219 feet (67 m) south, and a change in elevation of 10,765 feet from the top of the hole to the bottom (a s compared to the 10,788 feet downhole depth). The largest angular deviation from vertical was 9.5 degr ees, with this type of deviation to the south-southeast (approximately 160 deg. azimuth) at depths between approximately 6,500 feet and

8,000 feet (Figure E2-8).

Page E8 of 57 GEO. DCPP.TR.14.01, Rev. 0 This information may be useful for estimating lo cation uncertainties due to well drift for wells with no deviation information. To help with this , Table E2-3 below is an array that shows the horizontal distance change from the bottom of a hole to the top of a hole given hole depths ranging from 500 to 12,000 feet, and with aver age drift angles of 2, 5, and 10 degrees.

Table E2-3. Matrix of Scenario Well Deviations (in feet) for Consideration in Well Location Uncertainty Estimates Horizontal Change in Location (in ft.) from Top to Bottom of Hole Average Drift Angle (degrees) 2 5 10 Hole Depth (ft.) 500 17 44 87 1,000 35 87 174 2,000 70 174 347 4,000 140 349 695 8,000 279 697 1,389 12,000 419 1,046 2,084 E2.5 Digitization of the Sonic Log Data A is a type of acoustic log that displays travel time of P-waves through a short interval of rock in the well bore, versus depth. Sonic logs are typically recorded by pulling a tool on a wireline up the wellbore. The tool emits a sound wave that travels from the source to the formation and back to a receiver. The travel time of the sound wa ve is a function of the lithology and the density of the formation. Sonic logging was done in a relatively small perc entage of the wells drilled in the area. The continuous downhole method, invented in 1951 (Close et al., 2009), wa s not widely used in the San Luis Obispo area until the 1960s. Even then, while almost all wells have an e-log, only some have a sonic log.

The sonic log data consist of plots of travel time versus depth recorded by the downhole instrumentation. All were in paper format, variab le in scale and quality of the reproduction. To compare the sonic log data and perform quantitative analyses, the logs were first digitized.

The digitization procedure used a combination of Ar cGIS and Excel software to create a table of Vp versus depth. First, the paper logs were scanned and brought into GIS as images. Each image was then placed in an artificial geographic space, and georectified as if both axes of the logs were length in feet. In actuality, only the y-axis is in feet, and the x-axis is interval transit time, T, in seconds. The travel time curve was then digitized by setting point s along the line with a sufficient density to define the curve. Emphasi s was placed on setting th e points at inflection points and changes in direction of the curve.

The coordinates of the points that define the cu rve were then exported to Excel. To calculate a Vp profile, the length units that had been used fo r the x-axis were convert ed to interval transit Page E9 of 57 GEO. DCPP.TR.14.01, Rev. 0 time. Then interval transit time (T) was conve rted to P-wave velocity (Vp) by the following equation: Vp (feet per second) = 1,000,000/T A new plot was then created of Vp versus depth for each well. These plots are presented for 8 wells in Figures E2-9 through E2-12. The Excel files are provided in electronic format in electronic Section E10.0.

E3.0 WELL DATA SUMMARIES AND INTERPRETATION Data for each of the 26 oil wells and 8 hydroge ologic wells chosen fo r study are presented below, in order by API number (for oil well s), then hydrogeologic well number assigned by Cleath & Associates (2003). Tables E2-1 and E-2-2 thus may be us ed as an ordered listing of wells described below. Summary information includes whether the well is lo cated on or adjacent to the 2011 seismic-reflection surv ey, year drilled, total depth, el evation, source of data, and available data. Additional information include s a location descripti on, stratigraphic summary table with estimated formation top elevation, and discussion of stratigraphy. Formation names in some cases are provided by the geologist logging the core and may have

been written on the original logs or well summary sheet, although we note that "Monterey" may be consistent with either Monterey Formation or Miguelito Member, Pismo Formation in the project stratigraphic framework (Section E2.3). Formation names in all other wells were interpreted based on the lithol ogic descriptions, the geophys ical logs, paleontological information, and existing geologic mapping. The abbreviation "BOH" in the depth columns of the tables indicates the bottom of the hole, and "ND" in any column indicates "no data available." Graphic log data for 5 wells in the Irish Hills are compiled and presented on Plates E1 through E5. E3.1 API 07900174, Old See Canyon 1 ADJACENT TO 2011 SEISMIC-REFLECTION SURVEY

No YEAR DRILLED
1928 and 1937 T OTAL DEPTH
2,545 ft. (776 m)

E LEVATION , TOP OF WELL

Approx. 937 ft. (286 m)

SOURCE OF DATA

DOGGR files, Hall (1982; pers.comm., 2011)

A VAILABLE DATA

History file, including litholog ic log and geol ogist's report LOCATION: The location of this well is uncertain.

The location provided by the DOGGR database puts the well at an elevation of more than 900 f eet, in conflict with the reported elevation of 680 feet. Plotting the location in ArcGIS using the PLS grid and location information from the history file puts the well within 100 feet of the DOGGR location, again at an elevation above 900 feet. Either of these locations is near the Monterey Formation/Obispo Formation contact, which, according to mapping by Hall (1973a) dips to the southwest. The well, therefore, should Page E10 of 57 GEO. DCPP.TR.14.01, Rev. 0 penetrate only a short section of Monterey Formation before entering the Obispo Formation.

Instead, the well log suggests it pe netrates at least 694 feet (base of flint) of Monterey Formation. We considered whether the reported elevation might help locate the well. If the well is moved north to an elevation of 680 feet, it falls into an area mapped as Obispo Formation. Moving it south to lower elevations puts it into an area mapped as the Edna Member of the Pismo Formation. Here the well would have eventually penetrated Monterey Formation, but should have logged sandstone (Edna Member) over Monterey tuffaceous shale (Tmmts), first, which it does not. No reasonable location was consistent with both the reported elevation and the lithology reported in the well log.

Aerial photography, taken in 1939, two years after completion of the well, was examined for signs of roads and a well pad. No evidence was f ound in the vicinity of the plotted location, or anywhere within 2,000 feet of that location.

Therefore, the location of the See Canyon well remains uncertain. We estimate that the true lo cation does indeed lie wi thin 2,000 feet of the location provided by DOGGR and the well record, and is most likely to be we st or south of that location. Using the location from the DOGGR database, we estimate a ground elevation of the well at approximately 932 feet, based on the LiDAR-based project DEM. Assuming a 5-foot offset between the ground surface and the to p of the well (corresponding to zero depth on the logs), we estimate the elevation of the t op of the well to be 937 feet. Ba sed on the uncertainty in the location noted above, this elevation may have several hund red feet of uncertainty.

STRATIGRAPHY: According to the GMP geologic map, the well spudded in Monterey Formation.

The deepest unit encountered is described as a breccia with fragments of a variety of rock types. Consulting geologist George Wilbur examined the cores in 1937 and inte rpreted the breccia as a fault zone. His letter describing the core and explaining this interpretation is in the history file (see electronic Section E6.0). Ha ll (1982), however, interprets this unit as Franciscan Complex, an interpretation that appears to be inconsistent with the description of the core. Sweetkind et al.

(2010) adopt the Hall (1982) interpretation.

Dr. Hall explained in an August 2011 letter (see electronic Secti on E8.1) that the well should have encountered the Franciscan Complex above 2,275 feet based on a 900-foot maximum thickness of the Tertiary units in the area: The well spudded into the basal Monterey Formation (Tmmb, blocky dolomitic shale), whose maximum thickness in the area is approximately 200 feet. Stratigraphically beneath the Tmmb is the Obispo Formation (Tmo), with a maximum thickness in the immediate area of the well of approximately 500 feet. Beneath the Tmo is the Rincon Shale (Tmr) with a maximum thickness of approximately 100 feet in this area. Stratigraphically beneath the Tmr is the Vaqueros Formation (Tov), with a thickness that does not exceed 100 feet. Thus, the Tertiary section or the Tm of the well log could not be more than 900 feet thick and the top of the Franciscan Complex must be above the 2,275 feet of the well log.

Accounting for a dip of bedding of 65 to 70 degrees and assuming all Tertiary units are present in the expected thicknesses given by Hall, the top of the Franciscan Complex should have been Page E11 of 57 GEO. DCPP.TR.14.01, Rev. 0 encountered at 2,130 to 2,631 feet. Fr anciscan material was indeed encountered in the breccias at 2,275 to 2,545 feet. The main conflict, therefore, between Hall's interpretation and Wilbur's interpretation may be the identification of the material as in-place Franciscan Complex as opposed to fault breccia. This difference in interpretation is significant in the potential to use the presence of the fault breccia in this well as subsurface evidence for the Edna fault. A summary of the well interpretation, including a qualitative confidence assessment in the formation interpretations, is presented in Table E3-1. Table E3-1. Summary Interpretation of the Old See Canyon 1 Well Depth (ft.) Formation Lithology Confidence0 to 2,275 Undifferentiated Monterey, Obispo, Rincon, and Vaqueros Formations Blue and gray shale. Flint interbeds between 520 ft. and 698 ft. Includes beds of gray sand, shells, and conglomerate

below 698 ft. High 2,275 to 2,545 BOH Franciscan Complex and/or possible fault zone (Edna fault?) Breccia with fragments of rhyolite tuff, serpentinite, Monterey shale, gray sand, intrusive diabase.

Low E3.2 API 07900247, Maino-Gonzales 1 ADJACENT TO 2011 SEISMIC-REFLECTION SURVEY

Yes YEAR DRILLED
1937 T OTAL DEPTH: 1,575 ft. (480 m)

E LEVATION , TOP OF WELL: Approx. 317 ft. (97 m)

SOURCES OF DATA

DOGGR files, Hall (1982), Brunett i (pers. comm., 2013), CSUB Well Repository A VAILABLE DATA: History file, including well summary r ecord; brief lithologic log; report of abandonment; handwritten depths of formation cont acts; paleontology report by C. Canfield of Union Oil Company of California (1937)

LOCATION: The well history file reports the location of the Maino-Gonzales 1 well at 550 feet north and 330 feet east from the southwest corner of Section 24, T30S-R10E , and at an elevation of 310 feet measured from the derrick floor. Plotting this location in ArcGIS shows it to be approximately 70 feet northeast of the location in the DOGGR data base, with both locations in the floor of Hazard Canyon (Figure E2-3). Th e PLS-based location corresponds to a LiDAR-based elevation of 312 feet. Assuming the derrick floor is approximately 5 feet above the ground, the top of the well (at the derrick floor) is at approximately 317 f eet elevation. The uncertainty in this well location is estimated to be +/-300 feet (100 m). The uncertainty in elevation is estimated to be +/-20 feet (6 m). There is additional uncertainty in well location due to an uncertain amount and direction of well drift, or deviation from vertical. Sec tion E2.4 presents results for the Honolulu-Page E12 of 57 GEO. DCPP.TR.14.01, Rev. 0 Tidewater 1 well, the only well in the Irish Hi lls study area that has deviation information. Table E2-3 contains a summary matrix showing scenario horizontal changes from the bottom of hole to the top for various well depths and averag e drift angles.

For the Maino-Gonzales 1 well, which is approximately 1,600 feet deep, Table E2-3 suggests an additional +/-140 feet uncertainty in the location at the bottom of the well given a 5-degree average drift angle. This uncertainty should be considered during analysis of seismic-reflection profiles in the vicinity of the well.

STRATIGRAPHY: According to the GMP geologic map and the mapping of Hall (1973a), the well spudded in alluvium of Hazard Canyon that directly overlies the Miguelito Member of the Pismo Formation. The well records from 1937 state that the Monterey Formation extends to 1,564 feet where serpentine Franciscan Formation was encount ered. Drilling of the se rpentine continued to 1,575 feet, the total depth of the hole. The Log a nd Core Record describes the lithology above 1,564 feet as primarily shale w ith some sand intervals. As described in Section E2.3, the interpretation of the strata as Monterey Formation at the time of drilling in 1937 pre-dates the stratigraphic scheme of Hall (1973a) that defined the distinct Pismo Formation as separate from the Monterey Formation based on a locally recognized unconformity. The Miguelito Member is generally lithologically similar to the Monterey Formation.

The paleontology report provides detailed lithol ogic descriptions and includes a column recording foraminifer species al ong with radiolarians and sponge spicules. The report notes that pyrite was encountered at a depth of approximately 960 feet, a nd extended to the top of the serpentine. Paleontologist Charles Canfield of Union Oil Company of California did not identify any additional formation contacts in the well in 1937, and simply states, "The top of the

Franciscan in Gretna Oil Co. Gonzales #1 is 1,564 feet." We presume that the fauna he noted were consistent with those known from the Monterey Formation at that time. The geologic map and well information were evaluated to determine if the basal contact of the Miguelito Member of the Pismo Formation could be identified above the contact with Franciscan Complex serpentinite, and what Tertiary stratigraphic units below the Miguelito Member may be present. The GMP geologic map shows the Main o-Gonzales 1 well to be located directly adjacent to the axial trace of a northwest-trending anticline (Plate 1 of the main GMP report). Approximately 2 km southeast of the well along the axial trace, the geologic map shows a breach of the anticline and an exposed sequence of, in descending order, Edna Member (Pismo Formation), Rincon Formation, Vaqueros Formati on, and Franciscan Complex serpentinite. In the breach, a tapering sliver of Obispo Formation is mapped on the southwest limb of the anticline. These map relations suggest that an eros ional event prior to or during deposition of the Pismo Formation eroded out the Monterey Formation and Obispo Formation along this portion of the northeast limb of the Pismo syncline. Approximately 2 km due east of the Maino-Gonzales 1 well, a sliver of serpentinite is mapped di rectly underlying Miguelito Member of the Pismo Formation adjacent to the core of another anticline (Plate 1 of the main GMP report), suggesting the erosional event may locally have cut out the lower Tertiary units as well. Approximately 5 km south-southwest of the Maino-Gonzales 1 well, on the opposite limb of the Pismo syncline near Point Buchon, the Miguelito Member of the Pismo Formation is mapped overlying the Monterey Formation (Hall, 1973a; Pl ate 1 of main report).

There, the contact appears gradational near or directly southwest of Coon Cr eek. Based on work by Keller and Page E13 of 57 GEO. DCPP.TR.14.01, Rev. 0 Barron (1993) and cited by Schwalbach and Bohacs (1996), diatom and silicoflagellate assemblages indicate a late Miocene (9 to 10.4 million years ago [Ma]) age of the base of the Miguelito Member at the Coon Creek site. This contrasting stratigraphi c relationship suggests that the Pismo Basin may have had considerable relief during the late Miocene, or that proximal and/or rapid faces changes in the Monterey and/or Pismo Formation have led to erroneous mapping. Thus, on the basis of geologic map evaluation, th e prediction for the Maino-Gonzales well would be that it penetrates the Miguelito Member of the Pismo Formation, then possibly the Edna Member, Rincon Formation, Vaqueros Sandstone, and serpentinite similar to the sequence seen in the breached anticline to the southeast. Alterna tively, it is possible that Monterey Formation is present in the well below the Pismo Formation if the structural and stratigraphic relations beneath the well are more simila r to those of the southwest limb of the Pismo Syncline near Coon Creek/Point Buchon.

Lithologic descriptions suggest that the top of the Monterey Formation, if present, may be present as shallow as the upper 100 feet of the well. The log shows gray siltstone and brown shale with streaks of calcite from 100 to 125 feet, becoming cherty at 150 feet. Most intervals below 150 feet are described as "cherty." Alt hough opaline chert and po rcelaneous shale are present in the Miguelito Member locally, these facies tend to be less common in the Miguelito Member as compared to the Monterey Formation.

An increase in chert is noted at 381 feet, along with notations of radiolarians and spicules. Therefore, the top of the Monterey Formation could tentatively be placed as shallow as 100 feet, the beginning of detailed logging of siltstone and shale, or perhaps as shallow as 381 feet, co rresponding to the noted increase in chert. A specimen of the foraminifer is noted at 504 feet. The specimen may be , a lower Luisian to lower Mohnian species. Kleinpell (1938) notes the occurrence of this species in both the Monterey Formation and th e Rincon Shale, but in the later stratigraphic framework of Hall (1973a), the species may be cons istent with the basal part of the Miguelito Member in accordance with the findings at Point Buchon (Keller and Barron, 1993). Alternatively, may be , a Repettian or younger species of probable Pliocene age that may be consistent w ith the upper part of the Miguelito Member. Miguelito Member or Monterey Formation likely continues to at least a depth of 1,047 feet, the

lowest depth for which chert is reported. From 1,047 to 1,486 feet, lithology is described as siltstone and shale with pyrite, radiolarians, and spicules. No specific foraminifer species are noted. Based on lithology, this interval would also be consistent with the Miguelito Member, Monterey Formation, or possibly the Rincon Formation. Silty sandstone is described from 1,486 to 1,564 feet. Again, pyrite, radiolarians, and spicules are present. No specific foraminifer species are not ed. Based on lithology this interval would be most consistent with either the Edna Member of the Pismo Formation or the Vaqueros Sandstone.

A summary of the well interpretation, including a qualitative confidence assessment in a preferred formation interpretation, is presented in Table E3-2. See Plate E1 for a graphical log of the Maino-Gonzales 1 well.

Page E14 of 57 GEO. DCPP.TR.14.01, Rev. 0 Table E3-2. Summary Interpretation of the Maino-Gonzales 1 Well Depth (ft.) Formation Lithology (from paleontology report) Confidence 0 to 36 Alluvium Surface wash High 36 to 100 Pismo Miguelito Member, or Monterey Siltstone and shale High 100 to 1,047 Pismo Miguelito Member, or Monterey Cherty siltstone and shale Moderate to

Low 1,047 to 1,486 Pismo Miguelito Member, or Monterey or Rincon Siltstone and shale with pyrite Low to Moderate 1,486 to 1,564 Pismo Edna Member, or Vaqueros Silty sandstone Low 1,564 to 1,575 Franciscan serpentine Serpentinized schist High E3.3 API 07900310, Pecho 1 ADJACENT TO 2011 SEISMIC-REFLECTION SURVEY

Yes YEARS DRILLED
1927 and 1937 T OTAL DEPTH: 2,745 ft. (837 m)

E LEVATION , TOP OF WELL: Approx. 176 ft. (54 m)

SOURCES OF DATA

DOGGR files, Hall (1982

), CSUB Well Repository A VAILABLE DATA

History file, including well summary record, brief lithologic log, report of abandonment, and paleontology report by Union Oil Co.

of California The well originally was drilled to 2,287 feet by the Painted Oil Company in 1927. Unfortunately, there are no records of this orig inal well. A.O. Lewis reoccupied the well in 1937 and deepened it to 2,745 feet. Thus, geologic information exists for the lower ~450 feet of the well. The well is described as a "surface anticline play."

LOCATION: The well history file reports the location of the Pecho 1 well at 1,339 feet south and 1,203 feet west from the southwest corner of Se ction 26, T30S-R10E, and at an elevation of 177 feet measured from the derrick floor. Plotti ng this location in ArcGIS shows it to be approximately 75 feet of the location in the DOGGR database, with both locations on a ridge directly north of Islay Creek at an elevation of approximately 200 feet (Figure E2-4) and the PLS location corresponding to a LiDAR elevation of 211 feet. The 7.5-minute USGS topographic map marks a "drill hole" approximately 200 feet west-southwest of the PLS-based location (Figure E2-4). The LiDAR elevation of this point is 171 feet, a much better match to the elevation from the well history report. Thus, the best estimate well location used in this study is the location provided on the USGS topographic map. Assuming the derrick floor is approximately 5 feet above the ground, the top of the well (at the derrick floor) is at Page E15 of 57 GEO. DCPP.TR.14.01, Rev. 0 approximately 176 feet elevation. Th e uncertainty in this well location is estimated to be +/-300 feet (100 m). The uncertainty in elevation is estimated to be +/-10 feet (3 m). There is additional uncertainty in well location due to an uncertain amount and direction of well drift, or deviation from vertical. Table E2-3 contains a summary matrix showing scenario horizontal changes from the bottom of hole to the top for various well depths and average drift angles. For the Pecho 1 well, which is approximately 2,700 feet deep, Table E2-3 suggests an additional +/-240 feet uncertainty in the location at the bottom of the well given a 5-degree average drift angle. This uncertainty should be considered during analysis of seismic-reflection profiles in the vicinity of the well.

STRATIGRAPHY: According to the GMP geologic map and the mapping of Hall (1973a), the well spudded in a thin veneer of marine terrace deposits overlying the Miguelito Member of the Pismo Formation near the mouth of Islay Creek (Plate 1 of main report). The well is located approximately 2 km north-northeast of the Monterey-Pismo Formation contact at Coon Creek near Point Buchon, and approximately 3.5 km west of the breached anticline described in Section E3.2 above in the discussion for the Maino-Gonzales 1 well. Stratigraphic information is available only for the interval from 2,287 to 2,745 feet. The Log and Core Record notes "hard brown shale" with "h ard sand," and the paleontology report describes the rock as "dark and light brown banded platy silt shale," consistent with the lithology of the Monterey Formation or Miguelito Member of the Pismo Formation. The paleontology report noted no fossils in the three core samples examined. The base of the Pismo Formation may be some where between 0 and 2,287 feet, or lower. Based on the well depth and distance from the mapped Pismo-Monterey Formation contact, the contact would have to have an average northeast dip of approximately 20 degrees or less to be encountered in the Pecho 1 well. Based on the numerous anticlines and synclines with

moderately dipping limbs between the well and th e contact, this is certainly plausible. Hall (1982) considers the entire well to be upper Miocene, and does not attempt to estimate the depth of the contact between the Pismo and Monterey Formations. With the information provided it is permissible that the entire well is within the Miguelito Member of the Pismo Formation; likewise it is permissible that the Pismo-Monterey Form ation contact is within the upper several hundred feet and the rest of the well is within Monterey Formation. A summary of the well interpretation, including a qualitative confidence assessment in a preferred formation contact interpretation, is presented in Table E3-3. See Plate E2 for a

graphical log of the available data for the Pecho 1 well. Table E3-3. Summary Interpretation of the Pecho 1 Well Depth (ft.) Formation Lithology Confidence 0 to 2,287 Pismo Formation, Miguelito Member, possibly containing contact with Monterey Formation ND. Records for this interval are missing.

Low 2,287 to 2,745 BOH Pismo Formation, Miguelito Member, or Monterey Formation Hard, dark and light brown banded, platy silt shale Low Page E16 of 57 GEO. DCPP.TR.14.01, Rev. 0 E3.4 API 07900378, Mello 2 ADJACENT TO 2011 SEISMIC-REFLECTION SURVEY

Yes YEAR DRILLED
1955 T OTAL DEPTH: 1,505 ft. (459 m)

E LEVATION , TOP OF WELL: Approx. 217 ft. (66 m)

SOURCE OF DATA: DOGGR files A VAILABLE DATA: History file, including well summary record; core log; e-log LOCATION: The location provided in the DOGGR file, pl acing the well adjacent to Pismo Creek near the head of Price Canyon, was accepted for this project. The LiDAR-based elevation from the project DEM for the prefe rred location is 213 feet. The reported offset between ground surface and top of well is 4 feet. Thus, the preferre d elevation of the top of the well is 217 feet. The uncertainty in this well location is estimated to be +/-300 feet (100 m). The uncertainty in elevation is estimated to be +/-10 feet (3 m). There is additional uncertainty in well location due to an uncertain amount and direction of well drift, or deviation from vertical. Table E2-3 contains a summary matrix showing scenario horizontal changes from the bottom of hole to the top for various well depths and average drift angles. For the Mello 2 well, which is approximately 1,500 feet deep, Table E2-3 suggests an additional +/-130 feet uncertainty in the location at the bottom of the well given a 5-degree average drift angle. This uncertainty should be considered during analysis of seismic-reflection profiles in the vicinity of the well.

STRATIGRAPHY: According to the mapping of Hall (1973b), the well spudded in alluvium of Pismo Creek overlying the Edna Member of the Pismo Formation near the head of Price Canyon. Monterey Formation is mapped directly north of the Mello 2 well as a fault-bounded sliver against Edna Member sandstone. Most dips at the surface are moderate to the south-southwest, and the relatively straight fault traces suggest moderately to steeply dipping faulting; likely to the south as well. According to the Well Summary Report, The Mello 2 well penetrates Pismo(?) between 0 and 380 feet, Monterey Formation between 380 feet and approximately 1,400 feet, and "Relizian(?)"

between 1,400 feet and 1,505 feet. Cores from 400 to 1,200 feet show sandstone, shale, conglomeratic siltstone, and silty sandstone locally with sandstone locally impregnated with tar that is consistent with the Edna Member mappe d at the surface by Hall (1973b) but also may be consistent with Monterey Formation. Dips reported in this interval are moderate (35 to 68 degrees). Cores from 1,304 to 1,325 feet show interbedded rhyolite tuff and sandstone, and a rhyolite/siltstone breccia. This lithology may be consistent with Monterey Formation but is also consistent with the bedded, fine-grained facies of the Obispo Formation. The closest Obispo Formation is mapped approximately 4 km northwest of the well along the Edna-Los Osos fault zone and 5 km south-southwest of the well near the mouth of Price Canyon. No lithologic data could be found for the 1,400-1,500 foot interval ex cept a handwritten note on the e-log that describes it as brown clay shale. The formation names were assi gned in the well summary report.

Page E17 of 57 GEO. DCPP.TR.14.01, Rev. 0 The Relizian age stated in the Well Summary Report would be most consistent with Obispo Formation elsewhere in the Pismo Basin, but may also be consistent with Monterey Formation.

Sweetkind et al. (2010) pr ovide an alternative interpretation of this well to the simple stratigraphy in the well history report. First, they place the top of the Monterey Formation at 980 feet instead of 380 feet. This may be a typographi cal error as there is no significant stratigraphic change noted at 980 feet in the well log. Second, they assign the rhyolite tuff bed encountered at approximately 1,305 feet along with all underlying strata to the Obispo Formation. Hall (1973b) shows tuff interbeds to be common in the lower Monterey Formation. Thus, it is permissible that Monterey Formation is present to the bottom of the well. A summary of the well interpretation, including a qualitative confidence assessment in a preferred formation contact interpre tation, is presented in Table E3-4. Table E3-4. Summary Interpretation of the Mello 2 Well Depth (ft.) Formation Lithology Confidence 0 to 380 Pismo Formation, Edna

Member High 380 to 1,305 Pismo Formation, Edna Member, possibly faulted with Monterey Formation 400-1,200 ft: sandstone, shale, conglomerate, siltstone; Pebble bed at 1,000 ft. Moderate 1,305 to 1,400 Obispo Formation or Monterey Formation 1,304-1,325 ft: rhyolite tuff, sandstone, rhyolite/ siltstone breccia Moderate to Low 1,305 to 1,505

BOH Obispo Formation or Monterey Formation Brown clay shale; "Relizian(?)"

noted in Well History Report Moderate to Low E3.5 API 07900380, Spooner 1 ADJACENT TO 2011 SEISMIC-REFLECTION SURVEY

Yes YEAR DRILLED
1953 T OTAL DEPTH: 1,749 ft. (533 m)

E LEVATION , TOP OF WELL: Approx. 527 ft. (161 m)

SOURCES OF DATA

DOGGR files, Hall (1982; pers. comm., 2011), Brunetti (pers. comm., 2013), CSUB Well Repository A VAILABLE DATA
History file, including driller's log (no geologic or lit hologic log); e-log; micro log; paleontology report by F. Crawford of Union Oil Company of California LOCATION: This well has been located precisely in the field by GMP geologists (Figure E2-3).

Prior to being located in the field, it was suspected that the well was mislocated in the DOGGR database. It is shown approxima tely 1,000 feet too far down the slope to the north, putting it on the north side of the Los Osos fault and at a low elevation. The USGS topographic map (Hall, 1973a) has marked it more correctly at an elevation of approximately 500 feet, close to its reported elevation of 462 feet. In 2012, the well head was located in th e field by GMP geologists Page E18 of 57 GEO. DCPP.TR.14.01, Rev. 0 and GPS coordinates were obtaine

d. The true location is indeed close to the location marked on the USGS topographic map, and it lies on the south side of the mapped trace of the Los Osos fault. The LiDAR-based elevation from the projec t DEM is 522 feet at the ground surface, much higher than the reported elevation. The estimate d offset between ground surface and top of well is 5 feet. Thus, the preferred elev ation of the top of the well is 527 feet. The uncertainty in this well location is estimated to be +/-3 feet (1 m). The uncertainty in elevation is estimated to be +/-10 feet (3 m).

The differences between the DOGGR database and the measured location of the Spooner 1 well is very large: 296 m horizontal difference between the measured location and the DOGGR database reported location. Such large uncertainties are hypothesized to result from an error introduced during the reporting of the well locatio n or during the digitizat ion process to create the DOGGR database. The very large difference between the elevation reported in the well history file (141 m) and the elevation from the LiDAR data at the location reported in the well history file (108 m) was flagged as problematic during the eval uation phase of the project, and led to a more thorough investigation into possibl e errors in the databa se well location. This investigation ultimately led to the request that the GMP map team locate the well in the field. There is additional uncertainty in well location due to an uncertain amount and direction of well drift, or deviation from vertical. Table E2-3 contains a summary matrix showing scenario horizontal changes from the bottom of hole to the top for various well depths and average drift angles. For the Spooner 1 well, which is approximately 1,750 feet deep, Table E2-3 suggests an additional +/-150 feet uncertainty in the location at the bottom of the well given a 5-degree average drift angle. This uncertainty should be considered during analysis of seismic-reflection profiles in the vicinity of the well.

STRATIGRAPHY: According to the GMP geologic map and the mapping of Lettis and Hall (1994) and Wiegers (2009), the well spudded in aeolian depos its flanking the northern slope of the Irish Hills directly north of Hazard Canyon. Small outcrops of the Miguelito Member of the Pismo Formation are present within 300 to 400 m east a nd west of the Spooner 1 well, and a continuous body of Miguelito is located approximately 500 m south of the well (Plate 1 of main report). Section E3.2 describes the map relations important to consider for inte rpreting the nearby Maino-Gonzales 1 well located approximately 500 m to the south of the Spooner 1 well. Stratigraphic interpretations are based on consideration of the geologic map; the paleontology report, which included notes on lithology and be nthic fauna below a depth of 600 feet; the driller's descriptions of the ma terials encountered at four de pths; a continu ous e-log that provided depths of major stratigraphic changes; and a microlog for the interval from 700 to 1,300 feet. No log information is available from the surface down to 201 feet. The well spudded in Quaternary aeolian sands, then th e driller lost circulation in a co arse gravel at 200 feet. They set casing from the surface to 210 feet. We interpret the upper 210 feet to be Quaternary materials, beginning with the aeolian deposits at the surface and e nding with porous fluvial gravels at 200 feet. Such alluvial deposits may be correlative to Quaternary "older alluvium" or Paso Robles Formation.

Page E19 of 57 GEO. DCPP.TR.14.01, Rev. 0 From 210 to 820 feet a unit with a fairly uniform low resistivity was encountered. The paleontology report describes the interval from 500 to 820 feet as shale and sand with some limestone. A sample from 790 feet is described as sand, even-grained, porous, and permeable. At the base of the unit, 809 to 814 feet depth, the log notes Monterey shale fragments deposited in sand, then a contact with the top of the Monterey Formation at 820 feet, a clear unconformity. We note again that at the time of drilling, the Miguelito Member had not been described and convention was to include what is now Miguelito Member within the Monterey Formation. The e-log shows a peak in resistivity at 800 feet, which may reflect the sand layer from 790 to 820 feet, underlain by a unit with alternating resistivity. We interpret the interval from 200 to 820 feet to belong to the upper part of the Pismo Formation or equivalent shallow marine Pliocene deposits, which may include the Squire Member sandstone, Bellevue Member claystone to fine sandstone, or Gragg Member fine to medium sandstone (Hall, 1973a). These units, and the age-correlative Careaga Formation, are typically weakly to moderately lithified marine deposits that would be indicative of the uniform low resistivity.

It is puzzling to note the absence of Miguelito Member in the well down to 820 feet given the mapped Miguelito Member outcroppings near the Spooner 1 well. It is plausible that these exposures were miside ntified, or alternatively, that upper Pismo Formation units are benched locally into the older lower Pismo Formation Miguelito Member. From 820 to 1,300 feet, the material exhibits altern ating resistivity, as typically encountered in interbedded mudstone, siltstone, and shales of the Miguelito Member and Monterey Formation. The paleontology report notes brown shale with some sandstone and limestone beds. Benthic foraminifera of early Mohnian age are present, consistent with both the lower portion of the Miguelito or the Monterey Formation. The geologic context of the well would favor an interpretation of Miguelito Member, but a true early Mohnian age would favor a Monterey Formation interpretation based on the approxima tely 10 Ma age of the contact at Coon Creek/Point Buchon. From 1,300 to approximately 1,600 feet, a similarly a lternating resistivity is observed in a more widely spaced pattern than above. Sand and shale are logged at 1,370 feet in a 16-foot length of core. The paleontology report notes that shale, siltstone, limestone, and sandstone are found throughout, with sandstone increas ing below 1,400 feet with Mohni an fauna. The lithologies are consistent with the interfingering of the Miguelito and Edna Members of the Pismo Formation, with increasing Edna sandstone at depth. This is equivalent to the map relations seen along structural trend to the southeast (Plate 1 of main report). However, alternative interpretations are possible, including placing this se quence within the Monterey Form ation, or assigning the lower fine sandstone to the Vaqueros Formation. Hall (1982), however, thought that the Franciscan Complex had been encountered at 1,300 feet, based on correlation with surface mapping.

In his letter dated August 2011 (see electronic Section E8.1), Hall explains his reasoning: Tpm at "Spooner" 1 rests unconformably on the Franciscan Complex, specifically greywacke (KJgw2). KJgw2 crops out approximately 1.5 miles east of the well

site. The Monterey, Obispo, Rincon, and Vaqueros formations thin to the west in this region and pinch out westward before the well site (MF-511 and USGS Map I 1097). The 1,300-foot depth from the well log (DOG) is agreement with a cross section drawn through the area; also, note Cross Section A-A on map sheet Page E20 of 57 GEO. DCPP.TR.14.01, Rev. 0 511. Elsewhere in the general area the Miguelito Member rests unconformably on metavolcanic rocks of the Franciscan Complex.

We feel this evidence is not as strong as the observations of lithology and benthic fauna contained in the paleontology report, which Hall may not have been aware of. The paleontology report places the contact between Monterey Formation and underlying Franciscan sandstone at 1,610 feet, based on ditch samples and the e-log. The Franciscan sandstone is described as medium to coarse varicolored sandstone. We note that this unit may also be Vaqueros Formation, which is mapped al ong trend within the breached anticline to the southeast. The Franciscan graywacke or Vaqueros Formation contact could be as high as 1,520 feet, based on description of coarse to medium sandstone at 1,535 and 1,590 feet and on the e-log signature. However, common to abundant benthi c fauna of Mohnian age are recorded at 1,590

feet, supporting the contact at 1,610 feet. Some Mohnian-age benthic fauna are also noted below 1,610 feet, however, it is likely that these were derived from higher in the hole. The samp les described in the paleontology report were ditch samples rather than core samples. We concur with the placement of the top of the Franciscan graywacke or Vaqueros Formation at 1,610 feet, but note that the contact may be approximate and the formation top is non-unique.

At 1,745 feet, serpentinite is logged in the core, indicating that basement has been reached by that depth. Serpentinite of the Franciscan Complex continues to the bottom of the hole at 1,749 feet. The serpentinite crops out at the base of the Tertiary section within the breached anticline southeast of the well. A summary of the well interpretation, including a qualitative confidence assessment in a preferred formation interpretation, is presented in Table E3-5. See Plate E3 for a graphical log of the Spooner 1 well. Table E3-5. Summary Interpretation of the Spooner 1 Well Depth (ft.) Formation Lithology (from paleontology report) Confidence 0 to 210 Quaternary aeolian and fluvial sediments Coarse gravel at 200 to 210 ft. Moderate to High210 to 820 Pismo Formation, Squire and/or other upper members Sand, shale, and limestone Moderate 820 to 1,300 Pismo Formation, Miguelito Member or Monterey Formation Brown shale with lower Mohnian fauna Low to Moderate 1,300 to 1,520 Pismo Formation, Miguelito Member, and/or Pismo Formation, Edna Member, or Monterey Formation Shale, limestone, and sandstone with Mohnian fauna Low to Moderate 1,520 to 1,610 Pismo Formation, Edna Member, or Monterey Formation or Vaqueros Formation or Franciscan graywacke Sandstone with Mohnian fauna Low to Moderate 1,610 to 1,745 Vaqueros Formation or Franciscan graywacke Sandstone Moderate Page E21 of 57 GEO. DCPP.TR.14.01, Rev. 0 Depth (ft.) Formation Lithology (from paleontology report) Confidence 1,745 to 1,749 Franciscan Complex serpentinite Serpentinite High E3.6 API 07900471, Bassi Core Hole 1 ADJACENT TO 2011 SEISMIC-REFLECTION SURVEY

No YEAR DRILLED
1962 T OTAL DEPTH: 959 ft. (292 m)

E LEVATION , TOP OF WELL: Approx. 208 ft. (63 m)

SOURCE OF DATA: DOGGR files A VAILABLE DATA: E-log with some hand notations LOCATION: The location provided in the DOGGR file wa s accepted for this project. The LiDAR-based elevation from the project DEM for the preferred location is 203 feet. The estimated offset between ground surface and top of we ll is 5 feet. Thus, the preferred elevation of the top of the well is 208 feet. The uncertainty in this well location is estimated to be +/-300 feet (100 m). The uncertainty in elevation is estimated to be +/-10 feet (3 m).

STRATIGRAPHY: According to the GMP geologic map and the mapping of Hall (1973b), the well spudded in the Squire Member of the Pismo Formation, within the core area of the Pismo syncline. Locally, the three Pliocene upper members of the Pismo Formation (Squire, Bellevue, and Gragg from highest to lowest) form a broad basin with the long synclin al axis trending east-west, which is approximately 30 degrees rotated from the more west-northwest/south-southeast-trending Pismo syncline in underlying lower Pismo Formation (mostly Miguelito Member). South of the broad upper Pismo Formation basin, Monterey Formation crops out, and north of the broad upper basin Miguelito Member, Pismo Formation crops out. The map relations indicate an angular unconformity between the upper members of the Pismo Formation and underlying Monterey Formation (to the south and southwest) and lower Pismo Formation (to the north). The well information is restricted to an e-log wi th handwritten notes. The notes include dark gray claystone at 500 feet depth and light gray well sorted claystone and sandstone at 750 feet. The third handwritten note indicates the Pismo-Monterey Formation contact at 670 feet coinciding with an increase in the average values and amp litudes of the resistivity log. Sweetkind et al.

(2010) concurs and notes this depth as the top of the Monterey Formation. However, the well is located on the north side of the east-west-trendi ng syncline axis, and is mo re likely to encounter Miguelito Member of the Pismo Formation than Monterey Formation below the upper Pismo Formation strata. It is also unclear if the we ll penetrated the entire upper part of the Pismo Formation, as explained below. The alternative stratigraphic interpretations for the Bassi Core Hole 1 well are explored using a simple map analysis of the doubly-plunging syncline in the upper Pismo Formation strata. The hole is on the north side of the longer, east-west-trending syncline axis, with the measured dips Page E22 of 57 GEO. DCPP.TR.14.01, Rev. 0 within the limbs of the syncline typically between approximately 20 degrees and 30 degrees (Hall, 1973b). The first hypothesis is that the change in resistivity at 670 feet depth is due to the change from less consolidated, Pliocene upper Pismo Formation members overlying more lithified and well bedded Miguelito Member. The distance from the well to the Miguelito Member-upper Pismo Formation (Gragg Member) contact is approximately 2,000 feet, which suggests the limb would have an average dip of 18 or 19 degrees to encounter Miguelito Member at 670 feet depth. This is certainly permissibl e within the range of dips shown on the map. Alternatively, the distance from the well to the Squire-Bellevue contact is approximately 1,500 feet. If the change in resistivity is due to the contact between the more massive, sandy Squire Member and the bedded buff to gray claystone and fine sandstone Bellevue Formation, the average dip of the limb is approximately 24 degrees. With a 24-degree dip, the total depth of the well-959 feet-would correspond to approximately the Miguelito-Gragg Formation contact. This, too, is permissible given the dips noted on the geologic map. Table E2-6 provides a summary of the alternative interpretations, including a qualitative measure of confidence in the preferred interpretation. Table E3-6. Summary Interpretation of the Bassi Core Hole 1 Well Depth (ft.) Formation Lithology Confidence0 to 670 Pismo Formation, Squire Member, or Pismo, upper members (Squire, Bellevue, and Gragg) Claystone at 500 ft. Moderate 670 to 959

BOH Pismo Formation, Bellevue and Gragg Members, or Pismo Formation, Miguelito Member Claystone and

sandstone at 750 ft. Moderate E3.7 API 07900477, Honolulu-Tidewater 1 ADJACENT TO 2011 SEISMIC-REFLECTION SURVEY

Yes YEAR DRILLED
1958 T OTAL DEPTH: 10,788 ft. (3,289 m)

E LEVATION , TOP OF WELL: Approx. 1,642 ft. (500 m)

SOURCES OF DATA

DOGGR files, Hall (1982), Chevron-Texaco (L. Knauer, pers. comm., 2013)

A VAILABLE DATA

History file; lithologic log and core r ecord; e-log; dip log, including deviation information; paleontology report by Union Oil Company of California (1958)

LOCATION: The wellhead was located in the field in 2012 by GMP geologists (Figure E2-5). The coordinates shown in the ArcGIS shapefile a nd on Plate E4 are taken from the on-the-ground GPS measurements at the wellhead. The true location is approximately 240 feet northwest of the location provided in the DOGGR database, and relatively close to the point marked "Drill Hole" on the USGS 7.5-minute topographic map (Figure E2

-5). The LiDAR-based elevation from the project DEM is 1,630 feet at the ground surface.

The offset between ground surface and the Kelly bushing provided in the history file is 12 f eet. Thus, the preferred elevation of the top of Page E23 of 57 GEO. DCPP.TR.14.01, Rev. 0 the well is 1,642 feet. The un certainty in this well location is estimated to be +/-3 feet (1 m). The uncertainty in elevation is estimated to be +/-10 feet (3 m). Deviation information for the Honolulu-Tidewater 1 well is incl uded with the dip log. Section E2.4 describes the approach for constructing a deviation log from these data, and Figure E2-8 shows plots of the results. The results show that , on average, the drilli ng angle was about three degrees from vertical, with the drift angle varying from zero to a maximum of 9.5 degrees. The estimated difference in location at the bottom of the hol e compared to the t op of the well is 220 feet to the east and 220 feet to the south. An Excel file containing the deviation log that may be used for plotting the drift information correctly is included as Appendix E4.

STRATIGRAPHY

At 10,788 feet, this is the d eepest well in the Irish Hills, drilled at the crest of a ridge in the center of the Pismo Syncline. Despite its great depth, the well did not reach basement rock. A graphic compilation of well log inform ation is presented in Plates E4a and E4b. According to the GMP geologic map and the ma pping of Hall (1973a), th e well spudded in the Miguelito Member of the Pismo Formation, within the core area of the Pismo syncline. The 1958 well log states that it begins in the upper Monterey Formation, consistent with the stratigraphic framework at that time, prior to the recognition of the unconformity-bounded Pismo Formation. The contact between the Miguelito Member and the Monterey Formation is unclear. Hall (1982) estimates the contact to be at approximately 100 feet depth but provides no rationale. We conclude that some portion of the unit identified in 1958 as the Upper Monterey Formation belongs to the Miguelito Member of the Pismo Formation, and designate the interval from a depth of approximately 100 to 1,037 f eet as belonging to either unit. Samples were collected and analyzed for microf ossils by paleontologists C.E. Sturz and Louis Simon. The samples in general contained meager fauna, with many samples barren. Samples from 20 to 560 feet depth contained Mohnian fauna consistent with Monterey or Pismo Formations. Samples from the shale beds at 5,400 to 5,600 feet contained Zemorrian fauna, consistent with Rincon Shale. Samples from 6,420 to 10,180 feet cont ained Saucesian fauna consistent with Obispo Formation (tuff, tuffaceous dolomitic sandstone and siltstone) or Rincon Formation. Kristin McDougall examined the fauna in the report and noted that the fauna in the interval from 5,400 to 5,600 feet seem older than the fauna from deeper in the hole (McDougall, pers. comm., 2013), suggesting an older-over-younger fault relation. The well log data suggest complex folding and faulting below the base of the Monterey Formation (Plate E4). Of particular note are ch anges in dip, the repeated stratigraphic sections, and the extreme thickness of the second Rincon shal e (3,820 feet, instead of the more typical 500 feet measured by Hall, 1973a). Several prominen t changes in dip direction are observed in the dip log. The change in dip at around 5,440 feet may be a fault or other structure within the Rincon shale. The core log reports that the rock is "moderately fractured and slickensided at varying angles." Dips above this interval had been steep to the south. Immediately below this interval, dips are to the northeast. Another dip change that corresponds to slickensides described in the core occurs at 9,000 feet within the second Rincon shale. The base of the Tertiary is estimated to be at approximately 12,000 feet (3,666 m) depth in the well, assuming that the top of the second tuff is the top of the Obispo Formation, and that the Page E24 of 57 GEO. DCPP.TR.14.01, Rev. 0 Obispo Formation, Rincon Formation, and Vaqueros Formation together comprise 1,850 feet. We note this approximation is very crude. A summary of the well interpretation, including a qualitative confidence assessment in a preferred formation contact interpretation, is presented in Table E3-7. See Plate E4 for a

graphical log of the available data for the Honolulu-Tidewater 1 well. Table E3-7. Summary Interpretation of the Honolulu-Tidewater 1 Well Depth (ft.) Formation Lithology Confidence 0 to 1,037 Pismo Formation, Miguelito Member, possibly containing contact with Monterey Formation Silt shale, with dolomite, clay shale, limestone, chert, and bentonite High 1,037 to 4,363 Monterey Formation Silt shale and dolomite with minor chert Brecciated at 3,080 ft. Moderate 4,363 to 4,722 Obispo Formation Silt shale with dolomite, with minor sandstone and bentonite Moderate to Low 4,722 to 5,370 Obispo Formation Tuff, with bentonite, sandstone, obsidian High 5,370 to 5,546 Rincon Formation Siltstone with foraminifera Fault at 5,500 ft.? Moderate 5,546 to 6,354 Obispo Formation Tuff, lithic and crystalline, siltstone, bentonite and obsidian, limestone Moderate 6,354 to 10,174 Rincon Formation or Obispo Formation Siltstone, with some tuff Fault at 9,000 ft.?

Low to Moderate 10,174 to 10,788 BOH Obispo Formation or Rincon Formation Tuff with silt shale Low to Moderate E3.8 API 07900478, Montadoro 1 ADJACENT TO 2011 SEISMIC-REFLECTION SURVEY

Yes YEAR DRILLED
1954 T OTAL DEPTH: 6,146 ft. (1,874 m)

E LEVATION , TOP OF WELL: Approx. 381 ft. (116 m)

SOURCES OF DATA

DOGGR files, Hall (1982), Brunetti (pers. comm., 2013)

A VAILABLE DATA: History file, includ ing core log; e-log LOCATION: The Montadoro 1 well is reported to be located 6,900 feet S and 1,850 feet W from the SW corner of Section 26, T30S, R10E, at an el evation of 375 feet at the "table." The height of the table is reported to be 10 feet above the ground surface, therefore the ground surface elevation is approximately 365 feet. The well location plotted from the PLS coordinates in Page E25 of 57 GEO. DCPP.TR.14.01, Rev. 0 ArcGIS is approximately 350 feet southeast of the location shown in the DOGGR database (Figure E2-6). The LiDAR-based elevation from the project DEM at the PLS-based location is 371 feet. Adding the 10-foot offset stated in the history file yields an elevation of 381 feet for the top of the Montadoro 1 well. The uncertainty in this well location is estimated to be +/-300 feet (100 m). The elevation uncertainty is estimated to be +/-20 feet (7 m).

There is additional uncertainty in well location due to an uncertain amount and direction of well drift, or deviation from vertical. Table E2-3 contains a summary matrix showing scenario horizontal changes from the bottom of hole to the top for various well depths and average drift angles. For the Montadoro 1 well, which is approximately 6,150 feet deep, Table E2-3 suggests an additional +/-530-foot uncertainty in the location at the bottom of the well given a 5-degree average drift angle. This uncertainty should be considered during analysis of seismic-reflection profiles in the vicinity of the well.

STRATIGRAPHY: The Montadoro 1 well is located near the center of the Pismo Syncline and penetrates a thick section of Miocene sediments. Similar to the Honolulu-Tidewater 1 well, the well does not reach basement. A graphic log of the information available for the Montadoro 1 well is provided on Plate E5. According to the GMP geologic map and mapping by Hall (1973a), the well spudded in Miguelito Member of the Pismo Formation. Hall's (1982) interpretation of the well places the base of the Pismo Formation at 200 feet but provides no rationale. We place a tentative contact at 1,700 feet based on a break in the e-log and a core sample description at 1,800 feet that is consistent with Monterey Formation. However, we acknowledge that the contact is approximate.

The base of the Monterey Formation is clearly indicated by a break on the e-log at 3,800 feet, with a corresponding change in lithology to the tuff of the Obispo Formation (Plate E5). Shale intervals are logged along with the tuff to a depth of 4,972 feet, where sandstone and tuffaceous

shale beds are encountered. Hall (1982) places an interval of Rincon shale here and interprets a fault at the base of the interv al at 5,155 feet, perhaps interpreting that the Obispo Formation repeats section. We consider that these sandstone and shale beds may be interbeds within the Obispo Formation similar to the tuffaceous to dolomitic and sandstone to siltstone interbeds mapped along the coast south of Point Buchon. Dr. Hall (pers. comm., 2011) was contacted requesting more information, but he was not able to shed any additional light on his interpretation of this well except to say that the log information was from notes taken at the DOGGR (Appendix E3).

Below 4,972 feet, beds of tuff, sandstone, and shale continue to the base of the well at 6,142 feet. This interval may be a continuation of the Obispo Formation, but could alternatively be interpreted as Rincon Formation with tuffaceous interbeds. Gouge and slickensides are common in this interval.

A summary of the well interpretation, including a qualitative confidence assessment in a preferred formation contact interp retation, is presented in Table E3-8. We note that, aside from the top of the Obispo Formation at approximately 3,800 feet, all formation contacts are approximately located and uncertain. See Plate E5 for a graphical log of the available data for the Montadoro 1 well.

Page E26 of 57 GEO. DCPP.TR.14.01, Rev. 0 Table E3-8. Summary Interpretation of the Montadoro 1 Well Depth (ft.) Formation Lithology* Confidence 0 to 1,700 Pismo Formation, Miguelito Member, possibly containing contact with Monterey Formation ND, not logged High 1,700 to 3,800 Monterey Formation, possibly containing contact with Pismo Miguelito Shale, limestone, and chert Moderate 3,800 to 4,972 Obispo Formation Tuff High 4,972 to 6,146

BOH Obispo and/or Rincon Formations Shale and tuff, with gouge and slickensides common throughout, especially near 6,000 ft.

Low to Moderate

  • Lithology is based on descriptions of core samples taken of various intervals. No continuous lithologic log was found in the records. Contact locations are interpreted primarily from changes in the e-log signature. E3.9 API 07900486, He ller Core Hole 1 ADJACENT TO 2011 SEISMIC-REFLECTION SURVEY
No YEAR DRILLED
1962 T OTAL DEPTH: 1,305 ft. (398 m)

E LEVATION , TOP OF WELL: Approx. 225 ft. (69 m)

SOURCE OF DATA: DOGGR files A VAILABLE DATA: History file with well summary and core descriptions (completion report);

e-log LOCATION: The location provided in the DOGGR file wa s accepted for this project. The LiDAR-based elevation from the project DEM for the pref erred location is 220 feet. The reported offset between ground surface and top of the well (measured to the derrick floor is 4 feet. Thus, the preferred elevation of the top of the well is 224 feet. The reported elevation is 279 feet, suggesting additional uncertainty in the well location. Thus, the uncertainty in this well location is estimated to be +/-600 feet (180 m). The uncertain ty in elevation is estim ated to be +/-70 feet (21 m). STRATIGRAPHY

According to the geologic map by Ha ll (1973b), the well spudded in the Miguelito and Edna Members of the Pismo Formation approximately at the contact with the overlying Gragg Member of the Pismo Formation. The intermediate dips to the north (approximately 25 to 35 degrees) and the map suggest the well should encounter mostly Edna Member sandstone overlying and interbedded with siltstone and claystone of the Miguelito Member with Monterey Formation at depth.

Page E27 of 57 GEO. DCPP.TR.14.01, Rev. 0 Four cores were recovered from approximately 400 to 630 feet de pths that are described as containing silty sandstone (at approx. 400 ft. depth) to siltstone and claystone (below 400 ft.). The completion log also reports sidewall samples with sand and tar sand from 150 feet depth to approximately 310 feet, then silty claystone and siltstone from approximately 320 to 1,230 feet depth. The e-log shows a major break at approximately 310 feet that coincides with the lithology change reported in the sidewall core. There is no indication in the core log that chert or siliceous shale was encountered in the si ltstone interval, and there are no formation interpretations provided in the history file. Based on the information from the geologic map, e-log, and the sidewall core, we interpret a contact between Edna Member and Miguelito Member of the Pismo Formation at approximately 310 feet depth. The consistency in the sidewall co re descriptions and the spontaneous potential log suggests Miguelito Member is present to the bottom of the well, although we cannot rule out that the Miguelito-Monterey Formation contact ma y be present in the lower portion of the well, perhaps below the depth of the last sidewall core sample. A summary of the well interpretation, including a qualitative confidence assessment in a preferred formation contact interpretation, is presented in Table E3-9. Table E3-9. Summary Interpretation of the Heller Core Hole 1 Well Depth (ft.) Formation Lithology Confidence 0 to 310 Pismo Formation, Edna Member Sandstone, silty, hard with tar coatings on fractures High 310 to 1,305

BOH Pismo Formation, Miguelito Member; possibly including contact with Monterey Formation near the bottom of the well. Siltstone, claystone, Siltstone, hard High to Moderate E3.10 API 07900550, Townsend-Gunter 1 ADJACENT TO 2011 SEISMIC-REFLECTION SURVEY

No YEAR DRILLED
1956-1957 T OTAL DEPTH: 3,286 ft. (1,002 m)

E LEVATION , TOP OF WELL: Approx. 571 ft. (174 m)

SOURCES OF DATA

DOGGR files, Hall (1982; pers. comm., 2011)

A VAILABLE DATA

History file, including well summary report; e-log; caliper log; orientation log LOCATION: The location provided in the DOGGR file wa s accepted for this project. Hall (1973b) shows a drill hole symbol approximately 275 f eet to the north-northeast that may be an alternative location for the well. The LiDAR-based elevation from the project DEM for the DOGGR location is 567 feet. The LiDAR-based elevations for the nearby well shown by Hall (1973b) are similar to the elev ations at the DOGGR location.

The reported offset between ground surface and top of well is 4 feet. Thus, the preferred elevation of th e top of the well is 571 feet. The reported elevation is 493 feet, sugges ting additional uncertainty in the well location.

Page E28 of 57 GEO. DCPP.TR.14.01, Rev. 0 We estimate the uncertainty in this well location to be +/-600 feet (180 m). The uncertainty in elevation is estimated to be +/-90 feet (27 m).

STRATIGRAPHY: According to the GMP geologic map and Hall (1973b), the well spudded in Miguelito Member (DOGGR location) or Edna Member (Hall (1973b) location) of the Pismo Formation on the north-eastern limb of the Pismo syncline, within a secondary fold structure called the See Canyon anticline. According to Mr. Townsend's 1957 letter to the CaDOG, its target was the Vaqueros sandstone, with a seco ndary objective to determine the depth to basement in the See anticline. The 1957 well summ ary report provides the de pths of the top of the Monterey Formation, Obispo Formation, and basement. Reported dips from cores include 40 to 60 degrees at 2,500 feet (within Obispo Formation). Hall (1982) interprets the well to begin in the Pismo Formation, and he places the top of the Vaqueros Formation sandstone at 2,750 feet and the top of the Franciscan Complex (KJf) at 2,950 feet. In his August 2011 letter (electronic Section E8.1), Hall reports that he relied on the geologic mapping and measured thicknesses of the units in local outcrops to interpret the depths of the top of the Vaqueros sandstone and Franciscan graywacke. Table E3-10 provides a summary interpretation of the well. A summary of the well interpretation, including a qualitative confidence assessment in a preferred formation contact interpreta tion, is presented in Table E3-10.

Edna fault dip: The top of serpentinite bedrock in this well could be interpreted to mark the location at depth of the Edna fault. Assuming a horizontal distance from the well to the fault trace at the surface of 2,200 to 2,300 feet, and a depth of the fault in the well of 3,270 feet, the dip of the Edna fault is approximately 55 degrees to the south-southwest. This interpretation is not unique, so this model-estimated dip of the E dna fault should be considered with caution. Table E3-10. Summary Interpretation of the Townsend-Gunter 1 Well Depth (ft.) Formation Lithology Confidence 0 to 805 Pismo ND High to Moderate 805 to 1,105 Monterey (lower Mohnian) Fractured shale Low to Moderate 1,105 to 2,750 Obispo (and Rincon?) Tuff High to Moderate 2,750 to 2,950 Vaqueros Sand ND Low to Moderate 2,950 to 3,270 Franciscan Complex "Hard sedimentary rock" Low to Moderate 3,270 to 3,286

BOH Franciscan Complex Serpentinite High E3.11 API 07900551, Townsend-Peterson 1 ADJACENT TO 2011 SEISMIC-REFLECTION SURVEY

No YEAR DRILLED
1956 T OTAL DEPTH: 1,445 ft. (440 m)

E LEVATION , TOP OF WELL: Approx. 129 ft. (39 m)

Page E29 of 57 GEO. DCPP.TR.14.01, Rev. 0 SOURCE OF DATA: DOGGR files A VAILABLE DATA

History file, including ditch log and well summary report; e-log LOCATION: The location provided in the DOGGR file wa s accepted for this project. Hall (1973b) shows two wells located approximately 1,100 and 1,200 feet north of the DOGGR location suggesting alternative locations. The LiDAR-based elevation from the project DEM for the preferred location is 125 feet, and elevations for the alterna tive Hall (1973b) bor ing locations are higher. The reported offset betw een ground surface and top of well is 4 feet. Thus, the preferred elevation of the top of the well is 129 feet. The reported elevati on for the top of the well is 87 feet, indicating there is additional uncertainty in the well location and the locations proposed by Hall (1973b) are not necessarily preferred. We estimate the uncertainty in this well location to be +/-600 feet (180 m). The uncertainty in elevation is estimated to be +/-50 feet (15 m).

STRATIGRAPHY

According to the GMP geologic map a nd Hall (1973b), the well spudded in the Miguelito Member of the Pismo Formation near the core of the Pismo syncline. Sweetkind et al. (2010) place the top of the Monterey Formation at the base of this well at 1,445 feet. However, there is no record in the ditch log or well summary report of the Monterey Formation. In our preferred interpretation, the Monterey Formation contact is assumed to be at some depth below the base of the well. Table E3-11 provides a summary interpretation of this well. Table E3-11. Summary Interpretation of the Townsend-Peterson 1 Well Depth (ft.) Formation Lithology Confidence 0 to 1,455

BOH Pismo Formation (Miguelito Member)

Siltstone, silty shale, with dolomite, and some porcelanite High to Moderate E3.12 API 07900581, Sousa 1 ADJACENT TO 2011 SEISMIC-REFLECTION SURVEY

Yes YEAR DRILLED
1955 T OTAL DEPTH: 1,233 ft. (376 m)

E LEVATION , TOP OF WELL

Approx. 45 ft. (14 m)

SOURCE OF DATA: DOGGR files A VAILABLE DATA: History file, including lithologic l og and sketch interpretation; e-log LOCATION: The well location is described as being 200 feet west of the road and 187 feet NW of the property line shown on a sketch map in the well record. This locati on, plotted using ArcGIS, is shown on Figure E2-7, and is located approximately 342 feet west of the point shown in the DOGGR database. The elevation of the ground surface at the well is reported to be 42 feet. The elevation at the location according to the well record is 39 feet. The reported offset between ground surface and top of well is 6 feet. Thus, the preferred elevation of th e top of the well is 45 feet. The uncertainty in this well location is estimated to be +/-300 feet (100 m). The uncertainty in elevation is estimated to be +/-10 feet (3 m).

Page E30 of 57 GEO. DCPP.TR.14.01, Rev. 0 There is additional uncertainty in well location due to an uncertain amount and direction of well drift, or deviation from vertical. Table E2-3 contains a summary matrix showing scenario horizontal changes from the bottom of hole to the top for various well depths and average drift angles. For the Sousa 1 well, which is approximately 1,200 feet deep, Table E2-3 suggests an additional +/-105 feet uncertainty in the location at the bottom of the well given a 5-degree average drift angle. This uncertainty should be considered during analysis of seismic-reflection profiles in the vicinity of the well.

STRATIGRAPHY

According to the GMP geologic map, Wi egers (2009), and Hall (1973a), the well spudded in thin alluvium overlying Franciscan Complex rocks near the boundary between metavolcanic rocks and mélange. The lithologic log indicates clay and gravelly alluvium overlying hard to very hard sandstone and shale of the Franciscan Complex to a depth of 1,234 feet. Some soft shale interbeds are noted. A summary of the well interpretation, including a qualitative confidence assessment in a preferred formation contact interpretation, is presented in Table E3-12. Table E3-12. Summary Interpretation of the Sousa 1 Well Depth (ft.) Formation Lithology Confidence 0 to 50 Quaternary alluvium Clay and gravel High 50 to 1,234 Franciscan Complex Hard sandstone and silty shale High E3.13 API 07900591, Signal ETS 1 ADJACENT TO 2011 SEISMIC-REFLECTION SURVEY
Yes YEAR DRILLED
1954 T OTAL DEPTH: 1,168 ft. (356 m)

E LEVATION , TOP OF WELL

Approx. 224 ft. (68 m)

SOURCE OF DATA: DOGGR files A VAILABLE DATA

History file and e-log *CADOGGR database shows a depth of 1,768 feet, transcribed from the well summary report.

This is probably an error. The driller's history report describes drilling only to 1,168 feet, and the e-log goes to 1,123 feet.

LOCATION: The location provided in the DOGGR file wa s accepted for this project. The LiDAR-based elevation from the project DEM for the pref erred location is 220 feet. The reported offset between ground surface and top of well is 4.4 feet. T hus, the preferred elevation of the top of the well is 204 feet. The uncertainty in this well location is estimated to be +/-300 feet (100 m). The uncertainty in elevation is estimated to be +/-10 feet (3 m). There is additional uncertainty in well location due to an uncertain amount and direction of well drift, or deviation from vertical. Table E2-3 contains a summary matrix showing scenario horizontal changes from the bottom of hole to the top for various well depths and average drift Page E31 of 57 GEO. DCPP.TR.14.01, Rev. 0 angles. For the Signal ETS 1 well, which is approximately 1,200 feet deep, Table E2-3 suggests an additional +/-105 feet uncertainty in the loca tion at the bottom of the well given a 5-degree average drift angle. This uncertainty should be considered during analysis of seismic-reflection profiles in the vicinity of the well.

STRATIGRAPHY: According to the mapping of Hall (1973b), the well spudded in alluvium of Pismo Creek overlying the Monterey Formation or Edna Member of the Pismo Formation near the head of Price Canyon. A fault contact between the Monterey Formation and Edna Member is located within the uncertainty of the well location.

Most dips at the surface are moderate to the south-southwest, and the relativel y straight fault traces suggest moderately to steeply dipping faulting; likely to th e south as well. The e-log for the Signal ETS 1 well matches reasonably well with the e-log of the nearby Mello 2 well (Section E3.4), despite the nearby faults juxtaposing the lithologically distinct Edna Member sandstone/siltstone and Monterey Formation shale. A one-page well summary report lists "hard shell" between 390 feet and 400 feet depth, and "Monterey-soft lt. br. Shale" at 620 feet depth. From the available information it is unclear whether the well is encountering Monterey Formation or Pismo Formation strata or is alternating between them. A summary of the well interpretation, including a qualitative confidence assessment in a preferred formation contact interpretation, is pr esented in Table E3-13. Table E3-13. Summary Interpretation of the Signal ETS 1 Well Depth (ft.) Formation Lithology Confidence 0 to 620 Monterey Formation and/or Pismo Formation Hard shell from 390 to 400 ft. Moderate to High 620 to 1,168

BOH Monterey Formation, based on E-Log Soft light brown shale High to Moderate E3.14 API 07900618, Rock 75 ADJACENT TO 2011 SEISMIC-REFLECTION SURVEY

Yes YEAR DRILLED
1965 T OTAL DEPTH: 2,200 ft. (671 m)

E LEVATION , TOP OF WELL: Approx. 317 ft. (97 m)

SOURCE OF DATA: DOGGR files.

A VAILABLE DATA

History file, including core record and well summary report; e-log with some hand notations LOCATION: The location provided in the DOGGR file wa s accepted for this project. The LiDAR-based elevation from the project DEM for the pref erred location is 308 feet. The reported offset between ground surface and top of well is 8.8 feet. T hus, the preferred elevation of the top of the well is 317 feet. The uncertainty in this well location is estimated to be +/-300 feet (100 m). The uncertainty in elevation is estimated to be +/-10 feet (3 m).

Page E32 of 57 GEO. DCPP.TR.14.01, Rev. 0 There is additional uncertainty in well location due to an uncertain amount and direction of well drift, or deviation from vertical. Table E2-3 contains a summary matrix showing scenario horizontal changes from the bottom of hole to the top for various well depths and average drift angles. For the Rock 75 well, which is 2,200 feet deep, Table E2-3 suggests an additional +/-190 feet uncertainty in the location at the bottom of the well given a 5-degree average drift angle.

This uncertainty should be considered during analysis of seismic-reflection profiles in the vicinity of the well.

STRATIGRAPHY: According to the mapping of Hall (1973b), the well spudded in Edna Member of the Pismo Formation near the head of Price Canyon.

A fault is located within the uncertainty of the well location that locally juxtaposes sub-units of the Edna Member differentiated by Hall (1973b). Most dips at the surface are moderate to the south-southwest.

The core record, which includes recovered core and sidewall cores, notes sand, bituminous sand, tar sand, and oil sand between 231 and 1,873 feet, with conglomerate between 500 feet and 520 feet and some siltstone interbeds between 1,748 and 2,019 feet depth. Notes for a sidewall core sample at 2,052 feet read, "fragments clay." Ha ndwritten notes on the e-log include 'Base of massive tar sand" at 590 feet a nd "Monterey" at 2,020 feet. We inte rpret this record as possibly indicating Monterey Formation below 2,020 feet, or alternatively, Miguelito Member of the Pismo Formation. A summary of the well interpretation, including a qualitative confidence assessment in a preferred formation contact interpreta tion, is presented in Table E3-14. Table E3-14. Summary Interpretation of the Rock 75 Well Depth (ft.) Formation Lithology Confidence 0 to 1,500 Pismo Formation, Edna

Member Sand and tar sand High 1,500 to 2,030 Pismo Formation, Edna

Member Oil sand with siltstone

interbeds High 2,030 to 2,200

BOH Monterey Formation or Pismo Formation, Miguelito Member Siltstone; clay fragments Moderate E3.15 API 07900654, Holmes 1 ADJACENT TO 2011 SEISMIC-REFLECTION SURVEY

No YEAR DRILLED
1943 T OTAL DEPTH
3,935 ft. (1,200 m)

E LEVATION , TOP OF WELL: Approx. 103 ft. (31 m)

SOURCE OF DATA

DOGGR files A VAILABLE DATA
History file with core log, unit designations, and summary paleontology table; e-log with some handwritten notes Page E33 of 57 GEO. DCPP.TR.14.01, Rev. 0 LOCATION: The location provided in the DOGGR file wa s accepted for this project. The LiDAR-based elevation from the project DEM for the pref erred location is 98 feet. The estimated offset between ground surface and top of we ll is 5 feet. Thus, the preferred elevation of the top of the well is 103 feet. The uncertainty in this well location is estimated to be +/-300 feet (100 m). The uncertainty in elevation is estimated to be +/-10 feet (3 m).

STRATIGRAPHY: According to the mapping of Hall (1973b), the well spudded in the Miguelito Member of the Pismo Formation directly adjacent to the intra-formational contact with the Edna Member, in Price Canyon. The well is located south of the mapped axial trace of the Pismo syncline, in an area of intermediate dips to the northeast. The unconforma ble contact between the Pismo Formation and underlying Monterey Formation is located approximately 2,700 feet south-southwest of the well. The well log shows hard silty, somewhat silic eous shale in the uppe r 1,250 feet, then gray-brown, hard, massive, siliceous si lty shale below 1,250 ft, consistent with the Miguelito Member of Hall (1973b). The abundant fossils are all noted to indicate "lower Pismo (i.e., Sisquoc)." At 2,100 feet depth, the well log declares top of Monterey Formation based on "Slumberger and change in type of foraminifera." From 2,100 feet to approximately 2,500 feet, the core is described as siltstone with tar, and below 2,500 feet to the bottom of the hole the descriptions are predominantly of cherty shale. A summary table of stratigraphic interpretations from the Holmes 1 well is provided in the history file. The table reports "Pismo" between 0 and 2,100 feet depth with no benthic foraminifer zone call. Below Pismo, in order, are "Arenaceous Z. (Delmontian), 2,100 ft. to 2,500 ft., Cherty Z. (U. Mohnian), 2,500 ft. to 3,020 ft., Bent. Brn. (L. Mohnian), 3,020 ft. to 3,540 ft., and finally Buff & Brn. (L. Mohnian), 3,540 ft. to 3,935 ft." The clear implication is that the stratigraphic scheme for the Arroyo Grande area is that the Monterey Formation spans the Luisian, Mohnian, and into the Delmontian benthic foraminifera zones, and that the Pismo Formation is Delmontian or younger. This is apparently in conflict with the mapped Monterey-Pismo Formation contact near Point Buchon, which has been dated to approximately 10 Ma, within the Mohnian benthic foraminifer zone. Thus, we suggest that the uncertainty in the location of the Pismo-Monterey c ontact is between the 2,100 feet depth, consistent with the well report, and perhaps the 2,500 feet depth boundary between the upper two zones of the Monterey interpreted from the well stratigraphy. A summary of the well interpretation, including a qualitative confidence assessment in a preferred formation contact interpreta tion, is presented in Table E3-15. Table E3-15. Summary Interpretation of the Holmes 1 Well Depth (ft.) Formation Lithology Confidence 0 to 2,100 Pismo Formation, Miguelito

Member Silty shale, with fish and

foraminifera High 2,100 to 3,935 BOH Monterey Formation (or

Miguelito Member to 2,500 ft.)

Silty shale to 2,500 ft.,

then cherty shale Moderate to High

Page E34 of 57 GEO. DCPP.TR.14.01, Rev. 0 E3.16 API 07900671, Tar Springs 1A ADJACENT TO 2011 SEISMIC-REFLECTION SURVEY

No YEAR DRILLED
1965 T OTAL DEPTH: 3,744 ft. (1,141 m)

E LEVATION , TOP OF WELL

Approx. 1,120 ft. (341 m)

SOURCE OF DATA: DOGGR files A VAILABLE DATA

History file with core record and well summary report; sonic log; e-log LOCATION: The location provided in the DOGGR file wa s accepted for this project. The LiDAR-based elevation from the project DEM for the preferred location is 1,115 feet. The estimated offset between ground surface and top of well is 5 f eet. Thus, the preferred elevation of the top of the well is 1,120 feet. The reporte d elevation for the top of the well is "1,025+/-" feet, suggesting additional uncertainty in the well location. Thus, the uncertainty in this well location is estimated to be +/-600 feet (180 m). The uncertainty in elevation is estimated to be +/-100 feet (33 m).

STRATIGRAPHY

Easternmost of the wells studied, this 3,744-foot-deep well is primarily in the Monterey Formation. It provides a good picture of the variability of this formation with depth.

The well was drilled by Shell Oil Company in 1965, and proved unproductive for oil and gas. The surface is mapped as Santa Margarita sandstone, but at 350 feet where the sonic log begins, the well is interpreted to be in Monterey Formation. The core log describes dark brown shale, massive to laminated throughout. Dips range fr om 40 to 60 degrees, steepening to 80 to 90 degrees below 4,280 feet. Fracturi ng and slickensides are described from 3,300 to 3,700 feet. There were a number of other wells drilled in the Tar Springs area near Huasna Creek. The deepest was 079-00670, drilled to 10,000 feet in 1954. The well notes the base of the Santa Margarita Sand at 520 feet, the top of the middle Miocene at 7,100 f eet, and the top of the lower Miocene at 7,570 feet. The extreme thickness of the Monterey Formation (>5,000 ft.) in this area ma y be partly due to a high true thickness, and partly due to the steep di ps of the bedding resulting in a greater apparent thickness penetrated by the well. Core samples below 2,950 feet are described as ba dly fractured with cross-hatched pattern. Many of the fractures are healed, but the core breaks easily. The many fractures may account for the variability in the dip log at these depths. A summary of the well interpretation, including a qualitative confidence assessment in a preferred formation contact interpreta tion, is presented in Table E3-16.

Page E35 of 57 GEO. DCPP.TR.14.01, Rev. 0 Table E3-16. Summary Interpretation of the Tar Springs 1A Well Depth (ft.) Formation Lithology Confidence 0 to 350 Santa Margarita sandstone (basal contact not logged) Sandstone High 350 to 3,744

BOH Monterey Formation Shale, hard, siliceous in

places Moderate to high E3.17 API 07920532, Leroy F-7B ADJACENT TO 2011 SEISMIC-REFLECTION SURVEY

No YEAR DRILLED
1981 T OTAL DEPTH
7,310 ft. (2,229 m)

E LEVATION , TOP OF WELL: Approx. 100 ft. (30 m)

SOURCES OF DATA: DOGGR files and TGS-NOPEC A VAILABLE DATA

History file, including deviation log; sonic log for the lowest section; dipmeter logs (incomplete); injection records LOCATION: The location provided in the DOGGR file wa s accepted for this project. The LiDAR-based elevation from the project DEM for the pref erred location is 95 feet. The estimated offset between ground surface and top of we ll is 5 feet. Thus, the preferred elevation of the top of the well is 100 feet. The uncertainty in this well location is estimated to be +/-300 feet (100 m). The uncertainty in elevation is estimated to be +/-10 feet (3 m).

STRATIGRAPHY

Leroy F-7B is one of the deepest wells in the area at a total of 7,310 feet.

Located in the Guadalupe Oil fi eld near Point Sal in northern Santa Barbara County, this well penetrates a thick section of Tertiary sediments and the Cretaceous Knoxville Formation. It may have hit Franciscan Complex basement at the bottom. The initial application to drill the well stated that the well was expected to terminate in volcanic pillow basalt at 7,000 feet, presumably of the Point Sal ophiolite, but no record was found indicating whether basement was reached. No mudlog or lithologic unit data were available. The history file shows that an injection test in the Knoxville Formation was performed. The top of the Knoxville Formation is given to be 2,560 feet, and injection tests in intervals from approximately 3,300 to 6,300 feet in the Knoxville Formation are recorded. The lowest section, the only section for which we have a sonic log, was not tested. We assume this is also in the Knoxville Formation. Summary information for the Leroy F-7B well is provided in Table E3-17. Table E3-17. Summary Interpretation of the Leroy F-7B Well Depth (ft.) Formation Lithology Confidence 0 to 2,560 ND ND ND 2,560 to 7,310 BOH Knoxville Formation ND Moderate

Page E36 of 57 GEO. DCPP.TR.14.01, Rev. 0 E3.18 API 07920544, Guidetti A1 ADJACENT TO 2011 SEISMIC-REFLECTION SURVEY

No YEAR DRILLED
1982 T OTAL DEPTH: 3,050 ft. (930 m)

E LEVATION , TOP OF WELL: Approx. 576 ft. (176 m)

SOURCE OF DATA: DOGGR files A VAILABLE DATA

Mud log; dip log LOCATION: The location provided in the DOGGR file wa s accepted for this project. The LiDAR-based elevation from the project DEM for the preferred location is 571 feet. The estimated offset between ground surface and top of we ll is 5 feet. Thus, the preferred elevation of the top of the well is 576 feet. The uncertainty in this well location is estimated to be +/-300 feet (100 m). The uncertainty in elevation is estimated to be +/-10 feet (3 m).

This well is thefirst of a series of wells drilled in the 1980s in the western part of the Arroyo Grande oil field. This well is located on the south side of the Indian Knob fault, similar to Guidetti A4.

STRATIGRAPHY: According to the geologic map by Ha ll (1973b), the well spudded in Edna Member of the Pismo Formation near a series of folds adjacent to the Indian Knob fault. The mud log shows an abrupt change from predominan tly sandstone to cherty siltstone, shale, and minor limestone at 1,750 feet. The introduction of volcanics in the strata at approximately 2,870 feet and extending to the bottom of the hole mark the contact with Obispo Formation. The summary interpretation of the Guidetti A1 well is in Table E3-18. Table E3-18. Summary Interpretation of the Guidetti A1 Well Depth (ft.) Formation Lithology Confidence 0 to 1,750 Pismo Formation, mostly Edna Member Sandstone High 1,750 to 2,870 Monterey Formation Cherty siltstone and shale High to moderate 2,870 to 3,050

BOH Obispo Formation Volcanics, sand, silt, clay High E3.19 API 07920545, Guidetti A3 ADJACENT TO 2011 SEISMIC-REFLECTION SURVEY

No YEAR DRILLED
1982 Total depth: 3,050 ft. (930 m)

E LEVATION , TOP OF WELL: Approx. 367 ft. (112 m)

SOURCES OF DATA: DOGGR files and TGS-NOPEC Page E37 of 57 GEO. DCPP.TR.14.01, Rev. 0 A VAILABLE DATA: History file with sidewall core analysis log; mud log; sonic log; dip log; induction log LOCATION: The location provided in the DOGGR file wa s accepted for this project. The LiDAR-based elevation from the project DEM for the pref erred location is 354 feet. The reported offset between ground surface and top of well is 13 feet. Thus, the preferred elevation of the top of the well is 367 feet. The uncertainty in this well location is estimated to be +/-300 feet (100 m). The uncertainty in elevation is estimated to be +/-20 feet (6 m).

This well is one of a series of wells drilled in the 1980s in the we stern part of the Arroyo Grande oil field. This well is located on the north side of the Indian Knob fault, similar to Guidetti A7.

STRATIGRAPHY: According to the geologic map by Ha ll (1973b), the well spudded in Edna Member of the Pismo Formation on the north side of the Indian Knob fault. From the mud log, the top of the Monterey Formation is probabl y between 1,550 feet at the uppermost occurrence of diatomaceous siltstone, and 1,650 feet where th e log notes "Possible to p of Monterey Shale."

The well summary record notes the top of Monterey Formation at 1,640 feet (500 m). Volcanics, presumably of the Obispo Formation are encountered at 2,050 feet (625 m) and extend to the bottom of the hole at 3,050 feet (930 m). Assuming the volcanics belong to th e Obispo, the thickness of the Monterey Formation in this well is 650 feet (2,200 minus 1,550 ft.), to 410 feet (2,050 minus 1,640 ft.). This seems too thin. Faulting may have truncated the Monterey Forma tion. The change in dip direction at 1,860 feet within the Monterey Formation may be an indicator of a fault. Alternative interpretations for a thinner-than-expected Monterey Formation include deep erosion into the Monterey Formation by the overlying Pismo Formation, or if the volcanics are within the Monterey Formation. A summary of the well interpretation, including a qualitative confidence assessment in a preferred formation contact interpretation, is presented in Table E3-19. Table E3-19. Summary Interpretation of the Guidetti A3 Well Depth (ft.) Formation Lithology Confidence 0 to 1,640 Pismo Formation, Edna

Member Sandstone and siltstone High 1,640 to 2,050 Monterey Formation Siltstone, siliceous shale, diatomaceous siltstone Moderate 2,050 to 3,050 Obispo Formation Volcanics and sand Moderate to High E3.20 API 07920547, Guidetti A7 ADJACENT TO 2011 SEISMIC-REFLECTION SURVEY

No YEAR DRILLED
1982 T OTAL DEPTH: 2,751 ft. (839 m)

E LEVATION , TOP OF WELL: Approx. 666 ft. (203 m)

SOURCE OF DATA: DOGGR files Page E38 of 57 GEO. DCPP.TR.14.01, Rev. 0 A VAILABLE DATA: History file with well summary report and lithologic log; sidewall core log; mud log LOCATION: The location provided in the DOGGR file wa s accepted for this project. The LiDAR-based elevation from the project DEM for the pref erred location is 646 feet. The reported offset between ground surface and top of well is 20 feet. Thus, the preferred elevation of the top of the well is 666 feet. The uncertainty in this well location is estimated to be +/-300 feet (100 m). The uncertainty in elevation is estimated to be +/-20 feet (6 m).

This well is one of a series of wells drilled in the 1980s in the we stern part of the Arroyo Grande oil field. This well is located on the north side of the Indian Knob fault, similar to Guidetti A3.

STRATIGRAPHY: According to the geologic map by Ha ll (1973b), the well spudded in Edna Member of the Pismo Formation on the north side of an anticline trendi ng subparallel to the Indian Knob fault. From the mud log, the top of the Monterey Formation is approximately 1,475 feet deep at the transition from mostly sandstone to cherty siltstone and shale. The top of the Obispo Formation is probably at approximately 2,270 feet depth with the sudden presence of volcanics. A summary of the well interpretation, including a qualitative confidence assessment in a preferred formation contact interpretation, is presented in Table E3-20.

Table E3-20. Summary Interpretation of the Guidetti A7 Well Depth (ft.) Formation Lithology Confidence 0 to 1,475 Pismo (Edna) Formation Sandstone High 1,475 to 2,270 Monterey Formation Cherty siltstone and shale High 2,268 to 2,751 BOH Obispo Formation Volcanics and shale Moderate to high E2.21 API 07920566, Guidetti A4 ADJACENT TO 2011 SEISMIC-REFLECTION SURVEY

No YEAR DRILLED
1983 T OTAL DEPTH: 3,000 ft. (914 m)

E LEVATION , TOP OF WELL: Approx. 266 ft. (81 m)

SOURCES OF DATA: DOGGR files and TGS-NOPEC A VAILABLE DATA

Mud log; sonic log; dip log; induction log LOCATION: The location provided in the DOGGR file wa s accepted for this project. The LiDAR-based elevation from the project DEM for the pref erred location is 253 feet. The reported offset between ground surface and top of well is 13 feet. Thus, the preferred elevation of the top of the well is 266 feet. The uncertainty in this well location is estimated to be +/-300 feet (100 m). The uncertainty in elevation is estimated to be +/-20 feet (6 m).

This well is one of a series of wells drilled in the 1980s in the we stern part of the Arroyo Grande oil field. This well is located on the south side of the Indian Knob fault, similar to Guidetti A1.

Page E39 of 57 GEO. DCPP.TR.14.01, Rev. 0 STRATIGRAPHY

According to the geologic map by Ha ll (1973b), the well spudded in thin Quaternary alluvium overlying Edna Member of the Pismo Forma tion within a south-dipping dip panel with intermediate dips. The Miguelito Member is mapped north of th e well and directly on the south side of the Indian Knob fault. Based on the mud log, the upper 500 feet (152 m) is sandstone, presumably of the Edna Member of the Pismo Formation. From 500 to 1,320 feet, l ithology changes to siltstone that probably belongs to the Miguelito Member of the Pismo Formation. The Pismo/Monterey Formation contact is placed at approximately 1,320 feet (402 m), based on the first appearance of significant chert. This contact may be an unconformity based on the change in dip and dip direction at the contact.

There is evidence for a fault at 2,096 feet, where a mylonite zone with slickensides is logged in the core. The consistent 30- to 40-degree south dips in the Monterey Formation change abruptly at this depth to approximately 60 degrees southeast, then at 2, 700 feet they shallow and change direction again to 20-30 degrees southwest. The presence of a fault could account for the anomalously thick section of Monterey Formation here. Cross section B-B of Hall (1973b) shows the Indian K nob fault cutting through here in a way that thickens the Monterey Formation. If the mylonite zone is the Indian Knob fault, the fault dips south-southwes t approximately 55 degrees. A summary of the well interpretation, including a qualitative confidence assessment in a preferred formation contact interpreta tion, is presented in Table E3-21. Table E3-21. Summary Interpretation of the Guidetti A4 Well Depth (ft.) Formation Lithology Confidence 0 to 500 Pismo Formation, Edna

Member Sandstone High 500 to 1,320 Pismo Formation, Miguelito

Member Siltstone High to moderate 1,320 to 2,096 Monterey Formation Chert and siltstone Moderate to high 2,096 FAULT? Mylonite Moderate 2,096 to 2,961 Monterey Formation Cherty, dolomitic siltstone High E3.22 API 07920594, Shell Beach 1 ADJACENT TO 2011 SEISMIC-REFLECTION SURVEY

No YEAR DRILLED
1984 T OTAL DEPTH: 5,547 ft. (1,690 m)

E LEVATION , TOP OF WELL: Approx. 194 ft. (59 m)

SOURCES OF DATA: DOGGR files and TGS-NOPEC A VAILABLE DATA: History file; mud log; sonic log; e-log; dip log Page E40 of 57 GEO. DCPP.TR.14.01, Rev. 0 LOCATION: The location provided in the DOGGR file wa s accepted for this project. The LiDAR-based elevation from the project DEM for the pref erred location is 184 feet. The reported offset between ground surface and top of well is 10.5 feet. Thus, the preferred elevation of the top of the well is 194 feet. The uncertainty in this well location is estimated to be +/-300 feet (100 m). The uncertainty in elevation is estimated to be +/-25 feet (8 m).

STRATIGRAPHY

According to the geologic map by Hall (1973b), the well spudded in Obispo Formation among a series of approximately east-west-trending folds within the southern limb of the Pismo syncline. Drilled along the shoreline near Shell Beach, this well extended 5,547 feet (1,690 m) through a thick section of the Obispo Formation. A newspaper ar ticle in the history file states that the drillers were tr ying to reach the Vaqueros sandstone.

The newspaper article also stat es that the well was drilled st raight down to 1,000 feet, then angled 20 degrees to 2,500 feet, then down ag ain to the bottom. This was done to drill underneath the adjacent hill to the north. The dip log has a more detailed picture of the azimuth and exact angle of the hole at 100-foot intervals. Analysis of the dip log shows the bottom of the well to be located approximately 940 f eet north of the top of the well. A summary of the well interpretation, including a qualitative confidence assessment in a preferred formation contact interpreta tion, is presented in Table E3-22. Table E3-22. Summary Interpretation of the Shell Beach 1 Well Depth (ft.) Formation Lithology Confidence0 to 880 Obispo Formation, fine-grained

member Shale, sandstone, and siltstone with trace volcanic grains High 880 to 3,000 Obispo Formation Volcanics with interbedded

siltstone High 3,000 to 5,250 Obispo Formation, fine-grained member, resistant member, and possibly intrusive diabase member and/or including Rincon Formation Sandstone, claystone, and siltstone with glauconite and traces of volcanics Igneous rock (dike?), 70 ft. thick, at 4,000 ft. Moderate 5,250 to 5,547 BOH Obispo Formation? Sandstone, glauconitic, with traces of volcanic fragments Low E3.23 API 07921166, Rock 11G ADJACENT TO 2011 SEISMIC-REFLECTION SURVEY

Yes YEAR DRILLED
2008 T OTAL DEPTH: 2,005 ft. (611 m)

E LEVATION , TOP OF WELL: Approx. 210 ft. (64 m)

SOURCES OF DATA: DOGGR files and TGS-NOPEC A VAILABLE DATA: Sidewall core analysis

sonic log; e-log Page E41 of 57 GEO. DCPP.TR.14.01, Rev. 0 LOCATION
The location provided in the DOGGR file wa s accepted for this project. The LiDAR-based elevation from the project DEM for the pref erred location is 200 feet. The reported offset between ground surface and top of well is 10 feet. Thus, the preferred elevation of the top of the well is 210 feet. The uncertainty in this well location is estimated to be +/-300 feet (100 m). The uncertainty in elevation is estimated to be +/-10 feet (3 m). There is additional uncertainty in well location due to an uncertain amount and direction of well drift, or deviation from vertical. Table E2-3 contains a summary matrix showing scenario horizontal changes from the bottom of hole to the top for various well depths and average drift angles. For the Rock 11G well, which is approximately 2,000 feet deep, Table E2-3 suggests an additional +/-175 feet uncertainty in the location at the bottom of the well given a 5-degree average drift angle. This uncertainty should be considered during analysis of seismic-reflection profiles in the vicinity of the well.

STRATIGRAPHY: According to the mapping of Hall (1973b), the well spudd ed in shallow Quaternary alluvium of Pismo Creek overlying the Edna Member of the Pismo Formation in Price Canyon. Sonic log data were collected from 60 to 1,940 feet (18 to 592 m). There is no mud log or lithologic log among the available files, but sidewall core analyses show sand and silty sand throughout the well, with some mudstone below 1,650 feet. We interpret this record as the Edna Member of the Pismo Formation for the entire length of the well. A summary of the well interpretation, including a qualitative confidence assessment in a preferred formation contact interpreta tion, is presented in Table E3-23. Table E3-23. Summary Interpretation of the Rock 11G Well Depth (ft.) Formation Lithology Confidence 0 to 2,005 BOH Pismo Formation, Edna Member Sandstone High E3.24 API 560452001300, Offshore Well P-0435-1 ADJACENT TO 2011 SEISMIC-REFLECTION SURVEY

No YEAR DRILLED
1983 T OTAL DEPTH: 6,900 ft. (2,103 m)

E LEVATION , TOP OF WELL: Approximately 35 ft.

SOURCE OF DATA: Willingham et al. (2013)

A VAILABLE DATA: Gamma ray, resistivity, and sonic logs; identification of reflectors; partial mud log LOCATION: The well location was taken from the ArcGIS shapefile data of offshore Santa Maria basin wells developed by Fugro (Ventura office), the database used by Willingham et al. (2013). The estimated elevation of the top of the well is based on the information for the P-060-1 "Oceano" well provided by Hall (1982).

Page E42 of 57 GEO. DCPP.TR.14.01, Rev. 0 STRATIGRAPHY: This well is located on the west side of the Hosgri fault zone. Note that the depth to basement is significantly greater th an for P-0397-1, located on the east side of the Hosgri fault zone. Willingham et al. (2013) estimate over 850 m of basement displacement across the fault zone in this area. Table E3-24 shows a summary of depths to the tops of major unconformities and formations and a qualitative estimate of confidence in these boundaries. See Figure E2-12 for stratigraphic ma rkers plotted on the sonic log. Table 3-24. Summary Interpretation of the Offshore P-0435-1 Well Depth (ft.) Formation Lithology Confidence 1,300 Top of Miocene unconformity ND High 4,300 Top of Monterey Formation ND High 6,300 Knoxville Formation ND High 6,600 Franciscan Formation ND High E3.25 API 560462000100, Offshore Well P-060-1, Oceano 1 ADJACENT TO 2011 SEISMIC-REFLECTION SURVEY

No YEAR DRILLED
1965 T OTAL DEPTH: 8,020 ft. (2,445 m)

E LEVATION , TOP OF WELL

35 ft. SOURCES OF DATA
Hall (1982), McCulloch (1987), Miller and Meltzer (1999)

LOCATION: The well location was taken from the ArcGIS shapefile data of offshore Santa Maria basin wells developed by Fugro (Ventura office), the database used by Willingham et al. (2013). The estimated elevation of the t op of the well (Kelly bushing) is based on the information in Hall (1982). STRATIGRAPHY

Table E3-25 shows the interpreted depth intervals and formations and the lithology summaries as provided by Hall (1982) and as consistent with information provided in Figure 2 of Miller and Meltzer (1999) and Figure 9 of McCullo ch (1987). The interpretation by Hall (1982) was adopted as the most complete. A qualitative measure of confidence in the interpretations is also provided. Table E3-25. Summary Interpretation of the Offshore P-060-1, Oceano 1 Well Depth (ft.) Formation Lithology Confidence 0 to 1,220 Not logged ND ND 1,220 to 1,300 Pliocene?

ND Low to moderate 1,300 to 3,402 Foxen Mudstone Siltstone, sandstone High 3,402 to 5,484 Sisquoc Formation Shale High 5,484 to 6,660 Monterey Formation Siliceous shale, chert, limestone High 6,660 to 7,060 Obispo Formation Volcanic tuff, ash, flows, and sand High Page E43 of 57 GEO. DCPP.TR.14.01, Rev. 0 Depth (ft.) Formation Lithology Confidence 7,060 to 8,020 BOH KJf, or Jo, or Tl Volcanics, shale Moderate to high E3.26 API 560462000500, Offshore Well P-0397-1 ADJACENT TO 2011 SEISMIC-REFLECTION SURVEY

No YEAR DRILLED
1983 T OTAL DEPTH: 3,666 ft. (1,117 m)

E LEVATION , TOP OF WELL: Approximately 35 ft.

SOURCE OF DATA

Willingham et al. (2013)

A VAILABLE DATA: Gamma ray, resistivity, and sonic logs; identification of reflectors; partial mud log LOCATION: The well location was taken from the ArcGIS shapefile data of offshore Santa Maria basin wells developed by Fugro (Ventura office), the database used by Willingham et al. (2013). The estimated elevation of the top of the well is based on the information for the P-060-1 "Oceano" well provided by Hall (1982).

STRATIGRAPHY: This well is located on the east side of the Hosgri fault zone. Note that the depth to basement is significantly le ss than for P-0435-1, located on the west side of the Hosgri fault zone. Willingham et al. (2013) estimate over 850 m of basement displacement across the fault zone in this area. Table E3-26 shows a summary of depths to the tops of major unconformities and formations and a qualitative assessment of confidence in the interpretations of Willingham et al. (2013). See Figure E2-12 for stratigraphic markers plotted on the sonic log. Table E3-26. Summary Interpretation of the Offshore P-0397-1 Well Depth (ft.) Formation Lithology Confidence 1,050 Top of Pliocene unconformity ND High 1,350 Top of Miocene unconformity ND High 2,350 Top of Monterey Formation ND High 2,850 Top of Obispo Formation ND High 3,200 Top of Franciscan Formation ND High E3.27 30S/10E-13L4, CCW Pecho ADJACENT TO 2011 SEISMIC-REFLECTION SURVEY

Yes YEAR DRILLED
1977 T OTAL DEPTH: 675 ft. (206 m)

Page E44 of 57 GEO. DCPP.TR.14.01, Rev. 0 E LEVATION , TOP OF WELL: Approx. 71 ft. (22 m)

SOURCE OF DATA

Cleath & Associates (2003)

A VAILABLE DATA: California DWR well driller's report; e-log; sample log LOCATION: The location digitized from the Cleath & Associates (2003) compilation report was used for this project. The LiDAR-based elevation from the project DEM for the preferred location is 71 feet, which we use as a proxy for th e top of well elevation. Th is value is close to the 68 feet ground level elevation ta bulated in the e-log. The uncertain ty in this well location is estimated to be +/-300 feet (100 m).

The uncertainty in elevation is estimated to be +/-10 feet (3 m). Additional uncertainty in the location of the bottom of the well from well drift is estimated to be +/-60 feet based on an approximately 5-degree average deviation angle from vertical.

STRATIGRAPHY: According to the GMP geologic map and Lettis and Hall (1994), the well spudded in Quaternary aeolian de posits overlying older Quaterna ry deposits in the Morro Bay depression. The well is located approximately 4,000 feet (1,200 m) north of the closest mapped exposure of pre-Quaternary deposits (mapped exposures of the Miguelito Member of the Pismo Formation near the Spooner 1 well) (Plate 1 of ma in report). The location of the Los Osos fault zone is inferred to be between the Morro Ba y depression and the pre-Quaternary deposits exposed on the northern flank of the Irish Hills. The sample log shows well-rounded sand from the surface to 35 feet depth, underlain by a sequence of very fine sandy clay, very fine to medium sand, and gravel to a depth of 675 feet.

The gravels are typically describe d as well rounded, 1/8 inch (in.)

to 6 in. with chert, quartz, sandstone, diabase, dacite porphyr y, and siliceous rock types note

d. The e-log shows a change at approximately 475 to 500 feet de pth that coincides with a contact between (mostly) non-marine Paso Robles Formation alluvium "TQpr" overlying marine Careaga Formation "Tca" in interpreted cross section B-B' in the Cleath &

Associates (2003) report. Supporting the marine interpretation below 500 feet depth is a 2-foot-thick layer of sapropel, or black, slimy carbonaceous ooze, between gravel la yers at 611 to 613 feet depth.

At a depth of 675.5 feet, the drillers hit refusal, with the drag bit in hard gray sandstone noted to be, "very much like Franciscan sandstone." We note the possibility that, with only 0.5 foot of penetration, the rock encountered at 675 feet depth may be a boulder and not in-place basement rock. We interpret this well to contain thin aeolian sand overlying younger and then older alluvium to approximately 500 feet, very nearsh ore/beach deposits of probable Te rtiary age to 675 feet, then Franciscan Complex graywacke below 675 feet. In Table E3-27 we adopt the stratigraphic call of Pliocene Careaga Formation used by Cleath & Associates (2003) for the marine-affiliated deposits, although we note that these deposits may be facies equiva lents to upper Pismo Formation units, including the typically massive sandy Squire Member. We do not adopt the Paso Robles Formation designation for the terrestrial alluvial deposits, preferring the more generic term "older alluvium" of probable Plio-Pleistocene age. A summary of the well interpretation, including a qualitative confidence assessment in a preferred formation contact interpreta tion, is presented in Table E3-27.

Page E45 of 57 GEO. DCPP.TR.14.01, Rev. 0 Table E3-27. Summary Interpretation of the CCW Pecho Well Depth (ft.) Formation Lithology Confidence 0 to 35 Quaternary aeolian deposits Sand High 35 to 500 Younger alluvium overlying older alluvium of Plio-Pleistocene age Sandy clay, clayey sand, and gravel High to moderate 500 to 675 Careaga Formation Gravel, sand, and clay High to moderate 675 to 675.5 BOH Franciscan Complex Sandstone High to moderate E3.28 30S/10E-13Na, S&T New ADJACENT TO 2011 SEISMIC-REFLECTION SURVEY

Yes YEAR DRILLED
1999 T OTAL DEPTH: 500 ft. (152 m)

E LEVATION , TOP OF WELL: Approx. 137 ft. (42 m)

SOURCE OF DATA

Cleath & Associates (2003)

A VAILABLE DATA: California DWR well completion report; excerpts from summar y report; e-log LOCATION: The location digitized from the Cleath & Associates (2003) compilation report was used for this project. The LiDAR-based elevation from the project DEM for the preferred location is 137 feet, which we use as a proxy for th e top of well elevation. This value is close to the 140 feet elevation tabulated by Cleath & Associates (2003). The uncertainty in this well location is estimated to be +/-300 feet (100 m). The uncertainty in elevation is estimated to be +/-10 feet (3 m). Additional uncertainty in the location of the bottom of the well from well drift is estimated to be +/-50 feet based on an approximately 5-degree average deviation angle from vertical.

STRATIGRAPHY

According to the GMP geologic map and Lettis and Hall (1994), the well spudded in Quaternary aeolian de posits overlying older Quaterna ry deposits in the Morro Bay depression. The well is located approximately 2,900 feet (900 m) north of the closest mapped exposure of pre-Quaternary deposits (mapped exposures of the Miguelito Member of the Pismo Formation near the Spooner 1 well) (Plate 1 of ma in report). The location of the Los Osos fault zone is inferred to be between the Morro Ba y depression and the pre-Quaternary deposits exposed on the northern flank of the Irish Hills. The brief summary report excerpt states that, base d on the e-log and drill cuttings, sand is present at the surface to 100 feet dept h, sand, gravel, and sandy clay to a depth of 380 feet, and then mostly clay from 380 to 500 feet. Cleath & Associates (2003), on their cross section C-C', interpret dune sand from 0 to 50 feet, then Paso Robles Formation to the bottom of the well. A summary of the well interpretation, including a qualitative confidence assessment in a preferred formation contact interpreta tion, is presented in Table E3-28.

Page E46 of 57 GEO. DCPP.TR.14.01, Rev. 0 Table E3-28. Summary Interpretation of the S&T New Well Depth (ft.) Formation Lithology Confidence 0 to ~50 Quaternary aeolian deposits Sand High ~50 to 500 BOH Younger alluvium overlying older alluvium of Plio-Pleistocene age Sand, gravel, and sandy clay High to moderate E3.29 30S/11E-17E7, LOCSD-SB Deep ADJACENT TO 2011 SEISMIC-REFLECTION SURVEY

Yes YEAR DRILLED
ND T OTAL DEPTH: 560 ft. (171 m)

E LEVATION , TOP OF WELL

Approx. 114 ft. (35 m)

SOURCE OF DATA

Cleath & Associates (2003)

A VAILABLE DATA

Lithologic log; e-log LOCATION: The location digitized from the Cleath & Associates (2003) compilation report was used for this project. The LiDAR-based elevation from the project DEM for the preferred location is 114 feet, which we use as a proxy for th e top of well elevation. This value is close to the 106 feet elevation tabulated by Cleath & Associates (2003). The uncertainty in this well location is estimated to be +/-300 feet (100 m). The uncertainty in elevation is estimated to be +/-10 feet (3 m). Additional uncertainty in the location of the bottom of the well from well drift is estimated to be +/-50 feet based on an approximately 5-degree average deviation angle from vertical.

STRATIGRAPHY: According to the GMP geologic map and Lettis and Hall (1994), the well spudded in Quaternary aeolian de posits overlying older Quaterna ry deposits in the Morro Bay depression. The well is located approximately 6,000 feet (1,900 m) north of the closest mapped exposure of pre-Quaternary deposits (mapped exposures of the Miguelito Member of the Pismo Formation; Plate 1 of main report). The location of the Los Osos fault zone is inferred to be between the Morro Bay depression and the pre-Quaternary deposits exposed on the northern flank of the Irish Hills. The lithologic log for the SB deep well includes an interpretation that is consistent with the cross section F-F' in the main Cleath & Associates (2003) report. From 0 to 55 feet, the sub-rounded sand with some fine gravel is interpreted to be aeolian sand. From 55 to 474 feet, the well encountered medium to coarse sand, sandy clay, silty sand, and sand and gravel. This alluvium is subdivided in to upper and lower Paso Robles Formation. From 474 to 518 feet, apparently poorly lithified sandstone with abundant shell fragments and a 6-foot-thick clay interbed is interpreted to be Careaga Formation. From 518 feet to the bottom of the well, marine shale and sandstone is interpreted to be Franciscan Complex. A summary of the well interpretation, including a qualitative confidence assessment in a preferred formation contact interpreta tion, is presented in Table E3-29.

Page E47 of 57 GEO. DCPP.TR.14.01, Rev. 0 Table E3-29. Summary Interpretation of the LOCSD-SB Deep Well Depth (ft.) Formation Lithology Confidence 0 to 55 Quaternary aeolian deposits Sand High 55 to 474 Younger alluvium overlying older alluvium of Plio-Pleistocene age Sandy clay, silty sand, sand, and gravel High 474 to 518 Careaga Formation Sand(stone) with shell fragments and clay High to moderate 518 to 560 BOH Franciscan Complex Shale and sandstone High to moderate E3.30 30S/11E-17N10, CCW-SB #1 ADJACENT TO 2011 SEISMIC-REFLECTION SURVEY

Yes YEAR DRILLED
2001 T OTAL DEPTH: 750 ft. (229 m)

E LEVATION , TOP OF WELL: Approx. 150 ft. (46 m)

SOURCE OF DATA

Cleath & Associates (2003)

A VAILABLE DATA

California DWR well completion repor t; lithologic log; e-log LOCATION: The location digitized from the Cleath & Associates (2003) compilation report was used for this project. The LiDAR-based elevation from the project DEM for the preferred location is 150 feet, which we use as a proxy for th e top of well elevation. This value is close to the 136 feet elevation tabulated by Cleath & Associates (2003), and is equal to the "Approx. 150 ft." elevation noted in the Lithol ogic log. The uncertainty in this well location is estimated to be +/-300 feet (100 m). The uncertainty in elevation is estimated to be +/-20 feet (6 m). Additional uncertainty in the location of the bottom of the well from well drift is estimated to be +/-60 feet based on an approximately 5-degree average deviation angle from vertical.

STRATIGRAPHY: According to the GMP geologic map and Lettis and Hall (1994), the well spudded in Quaternary aeolian de posits overlying older Quaterna ry deposits in the Morro Bay depression. The well is located approximately 3,900 feet (1,200 m) north of the closest mapped exposure of pre-Quaternary deposits (mapped exposures of the Miguelito Member of the Pismo Formation; Plate 1 of main report). The location of the Los Osos fault zone is inferred to be between the Morro Bay depression and the pre-Quaternary deposits exposed on the northern flank of the Irish Hills. The lithologic log was produced by S. Harris of Cleath & Associates who provides his interpretation of the log on cross sections B-B' and F-F' in the Cleath & Associates (2003) report.

Sand to a depth of 37 feet is in terpreted as aeolian deposits. Alternating layers of clay, gravelly clay, sand and gravel, sandy clay, and sand extend to the bottom of the hole, with a comment about slow drilling and small, angular chips of hard, find-grained sandstone in the last 10 feet. Cleath & Associates (2003) interpret the bottom of the well to be in sandstone, presumably graywacke of the Franciscan Complex, and a contact between Paso Robles and Careaga Page E48 of 57 GEO. DCPP.TR.14.01, Rev. 0 Formation at approximately 525 feet. Beneath this depth are thick intervals of fine-grained sand with silty sand and clayey lenses, while above this interval layers of gr avelly sand with angular to sub-rounded fine gravel are common. A summary of the well interpretation, including a qualitative confidence assessment in a preferred formation contact interpreta tion, is presented in Table E3-30. Table E3-30. Summary Interpretation of the CCW-SB #1 Well Depth (ft.) Formation Lithology Confidence 0 to 37 Quaternary aeolian deposits Sand High 37 to 525 Younger alluvium overlying older alluvium of Plio-Pleistocene age Sandy clay, clayey sand, and gravelly clay and sand High 525 to 740 Careaga Formation sand, silty sand, clayey sand, and sandy clay Moderate to high 740 to 750

BOH Franciscan Complex Sandstone Moderate to high E3.31 30S/11E-18F2, LOCSD-Ferrell #2 ADJACENT TO 2011 SEISMIC-REFLECTION SURVEY

Yes YEAR DRILLED
1975 T OTAL DEPTH: 645 ft. (197 m)

E LEVATION , TOP OF WELL: Approx. 100 ft. (31 m)

SOURCE OF DATA

Cleath & Associates (2003)

A VAILABLE DATA: California DWR well driller's report; excerpt interpretation log from summary report LOCATION: The location digitized from the Cleath & Associates (2003) compilation report was used for this project. The LiDAR-based elevation from the project DEM for the preferred location is 100 feet, which we use as a proxy for th e top of well elevation. This value is equal to the elevation tabulated by Cleath & Associates (2003). The uncertainty in this well location is estimated to be +/-300 feet (100 m).

The uncertainty in elevation is estimated to be +/-10 feet (3 m). Additional uncertainty in the location of the bottom of the well from well drift is estimated to be +/-60 feet based on an approximately 5-degree average deviation angle from vertical.

STRATIGRAPHY: According to the GMP geologic map and Lettis and Hall (1994), the well spudded in Quaternary aeolian de posits overlying older Quaterna ry deposits in the Morro Bay depression. The well is located approximately 5,500 feet (1,700 m) north of the closest mapped exposure of pre-Quaternary deposits (mapped exposures of the Miguelito Member of the Pismo Formation; Plate 1 of main report). The location of the Los Osos fault zone is inferred to be Page E49 of 57 GEO. DCPP.TR.14.01, Rev. 0 between the Morro Bay depression and the pre-Quaternary deposits exposed on the northern flank of the Irish Hills. The water well driller's report contains an abbreviated description of materials encountered in the well, and Cleath & Associates (2003) provides an interpretation on cross sections H-H' and I-I' in their report. Sand encounter ed between 0 and 45 feet is inte rpreted as aeolian deposits. This is underlain by intervals of cla y, sand and gravel, and sandy clay to a depth of 600 feet. From 600 to 610 feet, the log notes "g ravel & sea shale (sandy)", wh ich Cleath & Associates (2003) interpret as Careaga Formation. From 610 to 645 feet, the log notes "brown shale" which is interpreted as pre-Careaga Formation, and possibly Franciscan Complex. A summary of the well interpretation, including a qualitative confidence assessment in a preferred formation contact interpreta tion, is presented in Table E3-31. Table E3-31. Summary Interpretation of the LOCSD-Ferrell #2 Well Depth (ft.) Formation Lithology Confidence 0 to 45 Quaternary aeolian deposits Sand High 45 to 600 Younger alluvium overlying older alluvium of Plio-Pleistocene age Clay, sand and gravel, and sandy clay High 600 to 610 Careaga Formation "gravel and sea shale" Low to moderate 610 to 645 BOH Franciscan Complex Shale Moderate to low E3.32 30S/11E-18K8, LOCSD-10th New ADJACENT TO 2011 SEISMIC-REFLECTION SURVEY

Yes YEAR DRILLED
ND T OTAL DEPTH: Approx. 650 ft. (198 m)

E LEVATION , TOP OF WELL

Approx. 134 ft. (41 m)

SOURCE OF DATA

Cleath & Associates (2003)

A VAILABLE DATA: Lithologic log; e-log with missing header LOCATION: The location digitized from the Cleath & Associates (2003) compilation report was used for this project. The LiDAR-based elevation from the project DEM for the preferred location is 134 feet, which we use as a proxy for th e top of well elevation. This value is close to the 136 feet elevation tabulated by Cleath & Associates (2003). The uncertainty in this well location is estimated to be +/-300 feet (100 m). The uncertainty in elevation is estimated to be +/-10 feet (3 m). Additional uncertainty in the location of the bottom of the well from well drift is estimated to be +/-60 feet based on an approximately 5-degree average deviation angle from vertical.

STRATIGRAPHY: According to the GMP geologic map and Lettis and Hall (1994), the well spudded in Quaternary aeolian de posits overlying older Quaterna ry deposits in the Morro Bay Page E50 of 57 GEO. DCPP.TR.14.01, Rev. 0 depression. The well is located approximately 4,400 feet (1,300 m) north of the closest mapped exposure of pre-Quaternary deposits (mapped exposures of Miguelito Member, Pismo Formation; Plate 1 of main report). The location of the Los Osos fault zone is inferred to be between the Morro Bay depression and the pre-Quaternary deposits exposed on the northern flank of the Irish Hills. The lithologic log for the LOCSD-10th new well includes an interpretation that is consistent with the cross section B-B' in the main Cleath & Associates (2003) report. From 0 to 110 feet, the fine to medium sand is interpreted to be aeolian deposits. From 110 to 592 feet, the well encountered sandy clay, sand with gravel, clayey sand, and silty sand. This alluvium is subdivided into upper and lower Paso Robles Formation. From 592 feet to the bottom of the well, fine to medium sand with seashells is interpreted to be Careaga Formation. A summary of the well interpretation, including a qualitative confidence assessment in a preferred formation contact interpreta tion, is presented in Table E3-32. Table E3-32. Summary Interpretation of the LOCSD-10th New Well Depth (ft.) Formation Lithology Confidence 0 to 110 Quaternary aeolian deposits Sand High 110 to 592 Younger alluvium overlying older alluvium of Plio-Pleistocene age Sandy clay, sand with gravel, clayey sand, and

silty sand High 592 to 650 BOH Careaga Formation Sand with seashells High E3.33 30S/11E-18L2, LOCSD-Palisades ADJACENT TO 2011 SEISMIC-REFLECTION SURVEY

Yes YEAR DRILLED
1981 T OTAL DEPTH: 612 ft. (187 m)

E LEVATION , TOP OF WELL: Approx. 98 ft. (30 m)

SOURCE OF DATA

Cleath & Associates (2003)

A VAILABLE DATA: California DWR well driller's report; e-log with interpretation notes LOCATION: The location digitized from the Cleath & Associates (2003) compilation report was used for this project. The LiDAR-based elevation from the project DEM for the preferred location is 98 feet, which we use as a proxy for th e top of well elevation. Th is value is close to the 81 feet elevation tabulated by Cleath & Associates (2003). The uncertainty in this well location is estimated to be +/-300 feet (100 m). The uncertainty in elevation is estimated to be +/-20 feet (6 m). Additional uncertainty in the location of the bottom of the well from well drift is estimated to be +/-50 feet based on an approximately 5-degree average deviation angle from vertical.

STRATIGRAPHY: According to the GMP geologic map and Lettis and Hall (1994), the well spudded in Quaternary aeolian de posits overlying older Quaterna ry deposits in the Morro Bay Page E51 of 57 GEO. DCPP.TR.14.01, Rev. 0 depression. The well is located approximately 4,400 feet (1,300 m) north of the closest mapped exposure of pre-Quaternary deposits (mapped exposures of the Miguelito Member of the Pismo Formation; Plate 1 of main report). The location of the Los Osos fault zone is inferred to be between the Morro Bay depression and the pre-Quaternary deposits exposed on the northern flank of the Irish Hills. The water well driller's report contains brief descriptions of materials encountered, and Cleath &

Associates (2003) provide an interpretation on their cross section B-B' in the main report. Sand from 0 to 15 feet is interpreted as aeolian deposits. From 15 to 525 feet depth, the log describes sandy clay, sand, clay, and gravel with sand and clay that is interpreted as Paso Robles Formation. Below 520 feet to the bottom of the well at 612 feet, the log describes fine sand, sandy clay, clay, and sandy brown clay with gravel lenses. The lowest interval includes a description of sand and decomposed rock. The interval between approximately 525 feet to the bottom of the hole is interpreted as Careaga Formation. A summary of the well interpretation, including a qualitative confidence assessment in a preferred formation contact interpreta tion, is presented in Table E3-33. Table E3-33. Summary Interpretation of the LOCSD-Palisades Well Depth (ft.) Formation Lithology Confidence 0 to 15 Quaternary aeolian deposits Sand High 15 to 525 Younger alluvium overlying older alluvium of Plio-Pleistocene age Sandy clay, sand, clay, and gravel with sand and clay High 525 to 612 BOH Careaga Formation Fine sand, sandy clay, clay, sandy clay with gravel lenses Moderate E3.34 30S/11E-18L6, USGS-Palisades ADJACENT TO 2011 SEISMIC-REFLECTION SURVEY

Yes YEAR DRILLED
1985 T OTAL DEPTH
620 ft. (189 m)

E LEVATION , TOP OF WELL: Approx. 79 ft. (24 m)

SOURCE OF DATA

Cleath & Associates (2003)

A VAILABLE DATA: California DWR well driller's report; lithologic log; e-log LOCATION: The location digitized from the Cleath & Associates (2003) compilation report was used for this project. The LiDAR-based elevation from the project DEM for the preferred location is 79 feet, which we use as a proxy for th e top of well elevation. Th is value is close to the 76 feet elevation noted in the lithologic log compiled by Cleath & Associates (2003). The uncertainty in this well location is estimated to be +/-300 feet (100 m). The uncertainty in elevation is estimated to be +/-10 feet (3 m). Additional uncertainty in the location of the bottom Page E52 of 57 GEO. DCPP.TR.14.01, Rev. 0 of the well from well drift is estimated to be +/-50 feet based on an approximately 5-degree average deviation angle from vertical.

STRATIGRAPHY: According to the GMP geologic map and Lettis and Hall (1994), the well spudded in Quaternary aeolian de posits overlying older Quaterna ry deposits in the Morro Bay depression. The well is located approximately 5,400 feet (1,600 m) north of the closest mapped exposure of pre-Quaternary deposits (mapped exposures of the Miguelito Member of the Pismo Formation; Plate 1 of main report). The location of the Los Osos fault zone is inferred to be between the Morro Bay depression and the pre-Quaternary deposits exposed on the northern flank of the Irish Hills. The lithologic log for the USGS-Palisades well was interpreted on cross section I-I' in Cleath & Associates (2003). Sand from 0 to 17 feet depth is interpreted as aeolian deposits. Intervals of clay, sandy clay, sand with gravel, silty clay and clay gravel betw een 17 and 554 feet are interpreted to be Paso Robles Formation. Below 554 feet to the bottom of the well at 620 feet, the log indicates sand with some porcelaneous white shaley chips and shell fragments within sand and gravel. The shaley chips are possibly broken gravels from the Monterey or Pismo Formation (Miguelito Member). This interval is interpreted as Careaga Formation. A summary of the well interpretation, including a qualitative confidence assessment in a preferred formation contact interpreta tion, is presented in Table E3-34. Table E3-34. Summary Interpretation of the USGS-Palisades Well Depth (ft.) Formation Lithology Confidence 0 to 17 Quaternary aeolian deposits Sand High 17 to 554 Younger alluvium overlying older alluvium of Plio-Pleistocene age Clay, sandy clay, silty clay, sand with gravel, and clay gravel High 554 to 620 BOH Careaga Formation Sand with shale chips and sand and gravel with shell

fragments High to moderate E4.0 VELOCITY CHARACTERISTICS FROM SONIC LOG DATA Sonic log data were selected and digitized with the purpose of providing information on the geophysical properties of stratigraphic units that are expected to be imaged in the seismic-reflection surveys. Figures E1-1, E2-1, and E2-2 show the locations of the wells with sonic log data compiled for this study. The methods for di gitizing the sonic log da ta are presented in Section E2.5. As mentioned previously, we ha ve not encountered s onic log data for the Honolulu-Tidewater 1 well, although the well history f ile states that sonic l ogs were collected in the lower portion of that well.

The digitized sonic logs, presented for 8 wells in Figures E2-9 through E2-12, form the basis for estimating typical velocities and ranges of ve locities for specific geologic units. Table E4-1 shows the mean velocity for each unit in each well, and the range within 90 percent of the plot Page E53 of 57 GEO. DCPP.TR.14.01, Rev. 0 falls in parentheses. These velocities may be considered to guide the processing of seismic-reflection survey data.

Page E54 of 57 GEO. DCPP.TR.14.01, Rev. 0 Velocity(x1000fps),mean(90%range)WellnameDepth(ft)Pliocene(offshore)PismoEdnaMbr.(ss,sltstn,sh)PismoMiguelito(sh,sltstn, ss)UpperMiocene(offshore)Monterey(sh,sltstn,cht)PointSal(sltstn,ss,shObispo(volcanics)Rincon(shale,ss,sltstn ,volc)Knoxville(sandstone)Franciscan P0397180034006.0(5.57.0)9.0(6.511.0)11.0(9.012.5)11.0(10.012.0)10.0(9.012.0)10.5(1 0.011.0)P0415110003800**6.0(5.07.0)6.5(6.07.0)**3,8009,700***8.5(7.59.5)***10.5(9.012.0)12.5(10.015.0)To+Paleogene12.0(11.014.0)P0422 103700**5.0(4.55.5)7.0(6.57.5)**370010,000***9.0(8.510.0)***12.0(9.015.0)13.0(12.015.0)P043518003300**6.5(6.07.0)7.0(6.57.5)**33006,500***9.5(8.010.5)***12.0(9.515.0)*14.0(12.015.0)15.0(14.016.5)TarSprings1A30013008.0(7.010.0)*1300200011.0(10.012.0)*2000370012.5(11.014.0)*ShellBeach50010008.5(7.011.0)100030008.5(7.011.0)3000520012.0(8.016.0)5200550017.5(15.019.0)Rock11G1002,0007.0(6.08.0)LeroyF7B6,6007,20015.0(13.016.0)GuidetiA36001,6506.0(5.08.0)1,6502100 6.5(5.08.0)210030009.0(7.012.0)GuidettiA46001,3009.5(7.510.5)1,3003,00010.0(9.011.0)*Velocityincreasessteadilywithdepthwithintheformation.**AbovetheOpalCT/Qtztransition***BelowtheOpalCT/QtztransitionNotes:Velocitiesareestimatedfromdownholesoniclogdepthplots,tothenearest500fps.Offshorewelldataarefromwelllo gplotsonPlate4ofWillinghametal.,2013.OnshorewelldataarefromsoniclogscompiledintheDCPPHistoricalWellsdatareport,preparedbyFugroConsultants,Jan2012.O f f

s h o r e O n s h o r eTable E4-1. Typical P-Wave Velocities from Sonic Log Data

Page E55 of 57 GEO. DCPP.TR.14.01, Rev. 0 E

5.0 REFERENCES

California Division of Oil, Gas, and Geothermal Resources (DOGGR), 2011. Database of well locations and attributes, downloaded from the website:

http://www.conservation .ca.gov/dog/maps/Pages/goto_welllocation.aspx, on May 24, 2011, by S. Thompson. The specific data files are for the District 3 Wells, and were downloaded in Excel and Shapefile format. Files are saved in Attachment C as Feb_District3Wells.xls, and D3Wells_Feb2011.zip (shapefile).

Cleath & Associates, 2003. Geologic Structure of the Los Osos Valley Ground Water Basin, Prepared for the Los Osos Community Services District, Main report with two appendices, Cleath & Associates, San Luis Obispo, California, November.

Close, D., Cho, D., Horn, F., and Edmundson, H., 2009. The Sound of Sonic: A Historical Perspective and Introduction to Acoustic Logging

CSEG Recorder, Canadian Society of Exploration Geophysicists, pp.

34-43; http://www.cseg.ca/publications/ recorder/2009/05may/May2009-Sound-of-Sonic.pdf.

Cole, R.B., and Stanley, R.G., 1998. Volcanic rocks of the Santa Maria Province, California: in Keller, M.A. (editor), , U.S. Geological Survey Bulletin 1995-R, 35 pp.

Dibblee, T.W., Jr., 2004. Geologic map of the San Luis Obispo quadrangle, San Luis Obispo County, California, Dibblee Geology Center Map #DF-129, Santa Barbara Museum of Natural History, Santa Barbara, CA, scale 1:24,000. Dibblee, T.W., Jr., 2006a. Geologic map of the Morro Bay South quadrangle, San Luis Obispo County, California, Dibblee Geology Center Map #DF-214, Santa Barbara Museum of Natural History, Santa Barbara, CA, scale 1:24,000. Dibblee, T.W., Jr., 2006b. Geologic map of the Pismo Beach quadrangle, San Luis Obispo County, California, Dibblee Geology Center Map #DF-212, Santa Barbara Museum of Natural History, Santa Barbara, CA, scale 1:24,000. Dibblee, T.W., Jr., 2006c. Geologic map of th e Port San Luis quadrangle, San Luis

Obispo County, California, Dibblee Geology Center Map #DF-213, Santa Barbara Museum of Natural History, Santa Barbara, CA, scale 1:24,000.

Eichhubl, P., and Behl, R.J., 1998. Diagenesis, deformation, and fluid flow in the Miocene Monterey Formation: in Special Publ ication of the Pacific Section Society of Economic Paleontologists and Mineralogists, Book 83, 98 pp. Hall, C.A., 1973a. Geologic map of the Morro Bay South and Port San Luis quadrangles, San Luis Obispo County, Califor nia: U.S. Geological Survey Miscellaneous Field Studies Map MF-511, scale 1:24,000.

Page E56 of 57 GEO. DCPP.TR.14.01, Rev. 0 Hall, C.A., 1973b. Geologic map of the Arroyo Grande quadrangle, San Luis Obispo County, California: California Division of Mines and Geology Map Sheet 24, scale 1:48,000.

Hall, C.A., Jr., 1982. Pre-Monterey subcrop and structure contour maps, western San Luis Obispo and Santa Barbara counties, south-central California: U.S. Geological Survey Miscellaneous Field Studies Map, MF-1384, 6 map sheets, plus 28 pp. of text. Lettis, W.R., and Hall, N.T., 1994. Los Osos fault zone, San Luis Obispo County, California: in Alterman, I.B., McMullen, R.B., Cluff, L.S., and Slemmons, D.B. (editors), , Geological Society of America Special Paper 292, pp.73-102.

Keller, M.A., and Barron, J.A., 1993. Re-evalu ation of the Miguelito Member of the Pismo Formation of Montana de Oro State Park, California, including new diatom age data [abs.]:  : 703-04. Keller, M.A., Tennyson, M.E., and Denison, R.E., 1996. Strontium isotope evidence for the age of the Vaqueros Formation and latest Oligocene marine transgression in the northern Santa Maria province, central California: in Keller, M.A. (editor), , U.S. Geological Survey Bulletin 1995-P, 8 pp.

Kleinpell, R.M., 1938. , The American Association of Petroleum Geologists, 526 pp.

McCulloch, D.S., 1987. Regional geology and h ydrocarbon potential of offshore central California: in Scholl, D.W., Grantz, A., and Vedder, J.G. (editors), , Houston Texas, Circum Pacific Council for Energy and Mineral Resources, Earth Science Series, Volume 6, pp. 353-401 Miller, K.C., and Meltzer, A.S., 1999. Struct ure and tectonics of the central offshore Santa Maria and Santa Lucia Basins, California: Results from the PG&E/EDGE seismic reflection survey: in Keller, M.A. (editor), , U.S. Geological Survey Bulletin 1995-Z, 12 pp. Schneider, J-L., and Fisher, R.V., 1996. Obispo Formation, California: Remobilized pyroclastic material: in Keller, M.A. (editor), , U.S. Geological Survey Bulletin 1995-O, 21 pp.

Schwalbach, J.R., and Bohacs, K.M., 1996.

Stratigraphic sections and gamma-ray spectrometry from five outcrops of the Monterey Formation in southwestern California:

Naples Beach, Point Pedernales, Lions Head, Shell Beach, and Point Buchon: in Keller, M.A. (editor), , U.S. Geological Survey Bulletin 1995-Q, 39 pp.

Page E57 of 57 GEO. DCPP.TR.14.01, Rev. 0 Sweetkind, D.S., Tennyson, M.E., Langenheim, V.E., and Shumaker, L.E., 2010. , U.S. Geological Survey Open-File Report 2010-1129, 11 pp. plus tables. Wiegers, M.O., 2009. Geologic map of the Morro Bay south 7.5' quadrangle, San Luis Obispo County, California: A digital database, Version 1.0, scale 1:24,000. William Lettis and Associates, Inc., 2001. Di ablo Canyon ISFSI Data Report A, Rev. 1, Geologic Mapping in the Plant Site Area and ISFSI Study Area. Willingham, C.R., Rietman, J.D., Heck, R.G., and Lettis, W.R., 2013. Characterization of the Hosgri Fault Zone and adjacent structures in the offshore Santa Maria Basin, south-central California: in Keller, M.A. (editor), , U.S. Geological Survey Bulletin 1995-CC, 105 pp., 7 plates.

Pacific Gas and Electric CompanyFigureFile path: S:\1005\020\QA_GIS\Final_Figures\Figure_E1-01.mxd; Date: 06/03/2014; User: Alex Remar, LCI

!A!A!A!A!A!A!A!A!A!A!A!A!A!A!A!A!A!A!A!A!A!A!A!A!A!A!A!A!A!A!A!A!A!A!A!A!A!A!A^_EsteroBaySan LuisObispo BayPrice Canyonstudy areaPacific OceanSanta MariaIrish Hillsstudy areaPoint SalPoint BuchonPointSan LuisCayucosCambriaLos OsosMorro BayPismo BeachPortSan LuisSan Luis ObispoDCPPFigure E2-1Figure E2-2 S T 1 S T 1£101£ 101TarSprings 1ALeroyF-7BP-0397-1P-0435-1P-060-1,Oceano 1-120°25'-120°25'-120°50'-120°50'35°30'35°30'35°0'35°0'^_SantaBarbaraCambriaPort San LuisDCPPMap projection and scale: WGS 84 / UTM Zone 10N,1:500,000Figure extentLocation of Selected WellsE1-1DCPP GEOLOGIC MAPPING PROJECT

+/-0510mi.01020kmEXPLANATION

!AHydrogeologic well

!AOil well!AOil well with sonic log Pacific Gas and Electric CompanyFigureFile path: S:\1005\020\QA_GIS\Final_Figures\Figure_E2-01.mxd; Date: 06/03/2014; User: Serkan Bozkurt, LCI

!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!

!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!

!!

!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!

!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!

!!!!!!!!!!!!!!!!!

!!!!!!!!!!!!!!!!!!!!!!!!!!!!

!!!!!!!!!!!!!!!!!!!!!!!!!

!!!!!!!!!!!!

!!!!!!!!!!!!!!!!!

!!

!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!

!!!!!!!!!!!!!!!!!

!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!

!!!!!!!!!!!

!!!

!!!!

!!!

!!

!!!!!

!!!

!!!!

!

!!

!!!!!

!!!!!!!!!!!!!

!!!!!

!!

!!!

!!!!!!

!!!!!!!

!!!!

!!!!!!

!!!!!!!!

!!

!!!!!!!!!!!!!

!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!

!!!!

!!

!!!!!

!!

!!

!!!

!!

!!

!!!

!!!!!!!!!!!!!!!

!!!!!

!!!!!!!!!!!!!

!!!!!!!!!!!

!!

!!!!!!!!!!!!!!!!

!!!!!!!!!!!!!!!!!!!!!

!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!

!!

!!!!!!!!!!!!!!!!!!!!!

!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!

!!!

!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!

!!!!!!!!!!

!!!

!!!

!!!!!!

!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!

!!!!!!!!!!!!!!!!!!!!!!!!!!!

!!!!!!!!!!!!!!!!!!!!!!!

!!!!!

!!!!!!!!!!!!!!!

!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!

!!!!!!!!!!!!!!!!!!!!!!!!!!!!

!!

!!!!!!!!!!!!!!!!!!!!!!!!!!!

!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!

!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!

!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!

!!!!!!!!

!!

!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!

!!!!!!!!!!!!!!!!!

!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!

!!!!!

!!!!!!!!!!!!!!!!!!!!!!

!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!

!!!!!!!!

!!!!!!!!

!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!

!!!!!!!

!!!!!!!!!!!!!!!

!!!!!

!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!

!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!

!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!

!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!

!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!

!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!

!!!!!!

!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!

!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!

!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!

!!!!!!!!!!

!!!!!!!!!!!!!!!!!!!!!!!!!!!

!

!!!!!!!!!!!!!!!!!!!

!!!!!!!!!!!!!!!!

!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!

!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!

!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!

!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!

!!

!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!

!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!

!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!

!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!

!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!

!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!

!!!!!!!

!!!

!!

!!!

!!

!!!

!!!

!!!!!!!!!!!!!!!!!!!!!!!!!!!!!

!!!

!!!

!!!!!

!!!!!

!!!!!!!!!

!!!!

!!!

!!

!!!!!!!!!!!!!!

!!

!!!!

!!!!!!!!!!!!!!!!!

!!!!!!!!!!!

!!!

!!!

!

!

!!!

!!!!

!!

!

!!

!

!!!!!

!!

!!

!!!!

!!!!!!!!!

!!!!

!!!!!!

!!

!!!

!!!

!!!

!!!!

!!

!

!!!!!

!

!!

!!!!!!!!

!!!

!!

!

!!!

!!!!!!!!!!!!

!!!!!!!!!!!!!!!!!

!!!!!!!!!

!!!!!!

!!!

!!!

!

!!

!!!!!!!

!!!!!!!!!!!!!!

!!

!

!!

!

!!!!!!

!!!!

!!!!!!

!!!!

!!!

!!!!!!

!!!!

!!

!

!

!!!

!!!

!!!!!!!!!!

!!!!!!!!

!!!

!!!!

!!!

!!!

!

!!!!!!!!!

!!!!!

!!

!!

!!

!!

!!!!!!!!!!

!

!!!

!!!!

!!!!

!!!!!

!

!!!!!!

!!!!!!

!!!!!

!!!

!!!!!

!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!

!!!!!!!!!!!!

!!!

!!!!!!!!!!!!!!!!!!

!!

!!!

!!!!!!

!

!!!

!!!!!!!!!!!!!!!!!!!!!!!!!!!!

!!!!!

!!!

!!

!!!!

!!!

!!!!!

!

!!!

!!!!!!

!!

!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!

!!!!!!!!

!!

!!!

!

!!!!!!!!!

!!!

!

!!!

!!!!!!!!!!!!!!!!!

!!

!

!!!!!!

!!!!

!!!

!!!

!

!!!!!!!

!!

!!!!

!!!

!!!!!!!!!!!!!!!!!!!

!!!!!

!!!!

!!!

!!

!!!!!!!

!!!!

!!!

!!!

!!

!!

!!

!

!

!!

!

!!!

!!!!!!!!!!

!!!!!

!!!!

!!!!!

!!!!!

!!!!!!!!!!!!!!!!

!!!

!!!!!!!!!!!!!!!!

!!!!!!!!!!!!

!!

!!!!!

!!!!

!!!!!!!!!

!!!!!

!!!!!

!!!!!

!!!!!!

!!!!!!!!

!!!

!!!!!!

!!

!!

!!!!!

!!!!!

!!!!!!

!!!

!!

!

!!!

!

!!

!!!

!

!

!!!

!!!!

!!

!!

!!!!!

!!!!

!!!

!!!!!!!!!!

!!!!!

!!

!

!!!

!!

!

!!!!

!!!!!

!!!!!!

!!!!!!!!!!!!!!!!!!!!!!!

!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!

!!!!!

!!!

!!

!!!!!

!!

!!!

!!

!!

!!!

!!

!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!

!!!!!!!!!!!

!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!

!!!!!!!!!!!

!!!!!!!

!!!!!!!!!!!

!!!

!!!

!!

!!!!!!!!

!

!!

!!!

!!

!!

!!!

!!

!!

!!!

!!

!!

!!!

!!!!!!

!!!!!!!

!!

!!

!!

!!

!!!

!!!!!!

!!!!!!

!

!!!!!!!!

!!

!!!!!!!!

!

!!!!

!!!

!!!!!!!!!

!!!!

!!!!

!!!

!

!!!!

!!!

!!

!!!

!!!

!!

!!!!!!!!

!!

!!!!!!!!!

!!!

!!

!!

!!!!!!!!

!!!!!!!!

!!!

!!

!!

!!!

!!

!!!

!!!!!!!

!!!!!

!!

!!!!!!!!!!!!!!

!!!!!!!!!!!!!

!!

!!!

!!!!!!!!!

!!

!!

!!!!!!!!!!!

!!!!

!!!!!!

!!!!

!!!

!!!

!!!

!!!

!!!!

!!!

!!!

!!!

!!!

!!!

!!!

!!!

!

!!!

!!!

!!!

!!!

!!!

!!!!!!

!!!

!

!!!

!!!

!!!

!!!

!!!!!!!

!!

!!

!!

!!!

!!!!!

!!!!!

!!!!

!!!

!!!

!!

!!!

!

!!!!!!!

!!

!

!!!!!!

!

!!!

!!!

!!!

!!!!

!!!!!!!

!!

!!

!!

!!!

!!

!!!!

!!!!!!!!!!!

!!!

!!!

!!!

!!

!!!!!!!!

!!!!!!

!!!

!!!

!!

!

!!!

!!!

!!!

!!!

!!!

!!!

!!!

!!!

!!!

!!!

!!!

!!

!

!!!

!!!

!!!

!!!

!!!

!!!

!!!

!!!

!

!!!!!

!!!

!!!

!!!

!!!

!!!!

!!!!!

!!!

!!!

!!!

!!!

!!!

!!!

!!!!

!

!!!

!!!!!!!!!!

!!

!!!!!!!!!!!!!!!!!!!

!!!

!!!

!!!

!!

!!!

!!

!!

!!

!!

!!

!

!!

!

!!

!

!!!!

!!

!

!!!!!!

!!!!!

!!!

!!

!

!!

!!!!!

!!!

!!!!!!!!

!!

!!!!!!!!!

!

!!!!!!!!!!!!!!!!!!!!!!!!!!!!

!!

!!!!

!!!

!!!

!!!

!!

!!

!!

!!!!!

!!

!!!!!!!!!!

!!!!!!!

!!

!!!

!!

!!!!!!!!!!!!

!

!!!!!!!!!!!!!!!!!!!!!!!!!!!!!

!!!!!!!!!

!!!!!!!!!

!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!

!!!

!!!!!!!!!!

!!!

!!!!!!!!

!!!

!!!

!!!

!!!!

!!!

!!!

!!!

!!!!

!!!

!!!!!!!!!!!!!

!!!!!!!!!!!!!!!!!!

!!!

!!!!!!!!!!!!!!!!

!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!

!!!!!!!!!!

!!!

!!!!!!!

!

!!!

!!!!!!!!!!!!!

!!!!!!

!!

!!

!!

!!

!!

!

!!!!!!!!!!!!!

!!!!

!!!!!!

!!!

!!

!!

!

!!

!

!

!!!

!!!!!!!!!

!!!!!

!

!!!!!!!!!!!!!!!!!!

!!!!!!!!

!!

!

!!

!

!!

!

!!!!!!!!

!!

!

!!!!!!!!!!

!!!!!!

!!

!

!!!!!!!!

!!

!

!!!

!!!!!!

!

!!!!

!

!!

!!

!!

!

!!

!

!!!!!!

!!!!!!

!!!!!!

!!

!

!!!!!

!

!!!!!!!

!

!!!!!!

!

!

!!!!!!!!!!!

!

!!!!!!!!!!!!!!!

!

!!!!!!!!!!!!!!!!!!

!!

!

!!!!!!!!

!!

!

!!

!!!!!!!!

!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!

!!

!!!!!!

!!!!!!!!!!

!!!!!!!

!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!

!!!!!!!!!!!!!!!

!!!!!!!!!!!

!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!

!!!!!

!!!!

!!!!!

!!!

!!!!

!!!!!!!!!!!!

!!

!!!!!!!!!!!!!!!!!!!!!!!!!

!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!

!!!

!!!

!!!!!!!!!!

!!!

!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!

!!!!!!!!!!!!!!!!!!!!!

!

!

!!!!!!!!

!!!!!

!!!!!!!!!

!!!

!!!!

!!!!

!!!!!!

!!!!

!!!

!!

!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!

!!!

!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!

!!

!

!

!!

!

!!

!

!!!!!!!

!!!!!!!!

!!!!

!!!

!!!

!!!

!!!

!!!

!!!!!

!!!

!

!!!

!!!!!!!!!!!!

!!!!!!!!!!!!!!!!!

!!!!

!!!

!

!!!!

!!!

!

!!!!

!!!!!!!!

!!!

!

!!!!

!!!

!

!!!!

!!!

!

!!!!

!!!

!

!!!!

!!!

!

!!!!

!!!

!!!!!!

!!!!!!

!!!!!!

!!!!

!!!

!!!

!!

!

!!!!!!

!!!

!!

!!!!!!

!!!!!!

!

!!

!

!!!

!!!!!

!!

!!!!!!!

!!

!!

!!

!!!!!!!!!!!

!!

!!!!!!!!!!!!!!!!!!!!!!!!!!

!!!!!!!!!

!!!!!!!!!!!!!!!

!!!!!!

!!

!!

!!

!!

!!

!!

!!!

!!

!!

!!

!!

!!!!!!

!!

!!

!!!

!!!!!!!!!!!

!!!!

!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!

!

!!!!!

!

!!!

!!!

!!!

!!!

!

!!!!

!!!

!!!

!!

!!

!!!!!!

!!!

!!

!!

!!

!!

!

!!!

!!!!!!!!!!

!!!!!!!

!!!

!!!

!!!

!!!

!!!

!!!

!!!

!!!

!

!!!!

!

!!!

!!!

!!!!!!!!

!!

!!

!!!

!!!!!!!!!!!!!!!!!!!!!!

!!!

!!!!!!!!!!!!

!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!

!!!!!!!!!!!!

!!

!

!!!!!!!!

!!!

!!!!!!!

!!!!!!!!!!!!!!!!!!!!

!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!

!!

!!!!!!!!!!!!!!!!!!!!!!!!

!!

!!

!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!

!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!

!!

!!

!!!!!!

!!!!!!!!

!!!

!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!

!!

!!!!!!!!!!!!!!!

!

!!

!

!!!!!!!!!!!!!!!!!!!!!!!!!!

!!!!!

!!

!!!!

!!

!!!!!!!!!!!!!!!

!

!!!!!!!

!

!!

!!!!

!!!!!!!!!!!!!

!!!!!!!!

!!!!!

!

!!!

!!!!!!!!!

!!!!

!!!!

!!!!!

!!!

!!!!

!!!

!!!!!!!!

!!!!!!!!!

!!!

!!!!!!!!!!!!

!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!

!!!!!!!!!!!!!!!!!!

!!!!

!

!!!

!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!

!!

!!!!!!!!!!!!!!!!!!

!!!!!

!!!

!

!!

!

!

!!!!!!

!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!

!!!

!!!!!!!!

!!

!!!!!!

!!!!!!!!!!!!!!!!!!

!!

!!

!!!!!!

!!!!!!!

!!!

!!!!

!

!

!!!

!!!!!

!!!

!!

!

!

!

!!!

!!!!

!!!!

!

!!!!!!!!!!!!!

!

!

!!

!

!!!!!

!

!

!!!!!!!!!!!!!!!

!!!!!!!!!!!!!

!

!!!!!!

!!

!!!!!!

!!!!!!!

!!

!!!!!

!!

!!!!!

!!

!!

!!

!

!!

!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!

!!!!!!!!!!!!!

!!!!!!!

!

!

!!!!!

!!!!!!!!!!!

!

!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!

!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!

!!!

!!

!

!!!!!!

!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!

!!!!!!!!!!!!!!!!

!

!!!!!!

!

!!!!

!!!!!!!!!

!!!!!!

!

!!

!!

!!!

!!!!!!

!!!!

!!!!!

!!!

!!

!!

!!

!!

!!!!!!!

!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!

!!!!!

!!!!

!!!!!!!!!

!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!

!!!!!!!!!!!!!!!!!!!!!!!!!!

!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!

!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!

!!!!!!!!!

!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!

!!!!

!!!!

!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!

!

!!

!

!!!

!!!

!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!

!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!

!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!

!!!

!!!!!!

!!

!

!!!

!!!!!!!

!!!!!!!!!!

!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!

!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!

!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!

!

!!

!!

!!!

!!!!!!

!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!

!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!

!

!

!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!

!!

!

!

!!

!

!!!!!!

!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!

!!!!!

!!!!!!

!!

!!!!!!!!!!!!

!!!!

!!!!!!!!!

!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!

!!!

!!!!

!!!

!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!

!!!!!!!!!!!!!!

!!!!

!!!!!!!!!!!!!!!!!!!!!

!!

!!

!

!!!

!!!

!!

!

!!!

!!!

!!!!!!!!!!!!!!

!!!

!!!!!

!!!!!!!!!!!!!!!

!!!!!!

!!!

!!

!

!!!!!!!

!!!

!

!!!!!!!!!!!

!!!

!!!!!!!!!!

!!!

!!!

!!!

!!!

!!!!

!!

!!!

!!

!!!

!!!!!!!!!!!!!!!!!!!!!!!!!!!!

!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!

!!!

!!

!!!

!!

!

!!!

!!

!

!!!!!

!!!!!!!!!!!!!!!!!!!!!!!!!!!!!

!!!

!!

!!

!!!

!!

!!

!!

!!!!!!!!!!!!!!!!

!!

!!!!!!!!

!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!

!!!

!!!

!!!

!!

!!!

!!

!!!!!

!!

!!!!

!!!!

!!!

!!

!!

!

!!

!

!!!!!!

!

!!!!!

!

!!!!!!!

!!!!!

!!!

!!

!!

!

!!

!!!!!!!!!!!

!!!!!!!!

!!!!!!!!!!!

!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!

!!!!!!!!!!!!!!!!

!!!!!!

!!!!!!!!!

!!!

!!!!!!!!!!!!!!!!!A!A!A!A!A!A!A!A!A!A!A!A!A!A^_Point Buchon^_Map projection and scale: WGS 84 / UTM Zone 10N,1:80,000+/-0 1 2mi.0 2 4km!AHydrogeologic well

!AOil well!AOil well with sonic logVibroseis lines and nodal receiversAWD lines!!!

Pacific Gas and Electric CompanyFigureFile path: S:\1005\020\QA_GIS\Final_Figures\Figure_E2-02.mxd; Date: 06/03/2014; User: Serkan Bozkurt, LCI

!!!

!!

!!!!!

!!

!!

!!!!!

!!

!!

!!!

!!

!!!!

!!!

!!!!!

!!!!!

!!!

!!!!!!!!!!!!!!

!!

!

!!!!!!!

!!

!

!!!!!!!

!!

!!!!!

!!!!!!!!!!!

!

!

!!!

!!

!!!!!!!

!!

!!

!!

!!!!!!!

!!

!

!!!!!!

!!!

!!!

!!

!!!

!!!

!!!!!!

!!!

!!!!!!

!!!

!!!!!!

!!!

!!

!

!!!!!!!!!!

!!

!

!!

!

!!!!!!!!!!!!!!!!!!!!!!!!!!!!

!!!

!!

!!

!!!

!!

!!

!!!!!!!!!!!!!!!!

!!

!!!

!!

!!

!!!!!!!!!!!!!!!!

!!!

!!!!!!!!!!!!!!!!!!!!!!!!!!

!!

!!!

!!!

!!!

!!!

!!!

!!!!

!!!

!!!

!!!!

!!!

!!!

!!!!

!!!

!!!!

!!!!

!!!

!!!

!!!!

!!!!!!!!!!

!!!

!!!

!!!!

!!!!

!!!

!!!

!!!!

!!!!!!

!!

!!!

!!

!!!!!

!!!

!!

!!!!!!

!!!!!!!

!!!

!!!!!

!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!

!!!

!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!

!!!!!!!!!!!!!!!!!!

!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!

!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!

!!!!

!!!!!!

!!

!!!

!!!!

!!!

!!!!!!!

!!!!!!!!!!!!!!!!!!

!!

!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!

!!!

!!!!

!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!

!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!

!!!

!!!!!!

!

!!!!

!

!!!!

!!

!

!

!!!!!!!!!!!!!!!!

!!!

!!!!

!!!!!!!!!!!!!!!!!!

!

!!!

!!

!!!!!!!

!!!!!!!

!!

!!!!

!!!

!

!!

!

!!!!!

!!!!!!!!!!!!!!!!!!!!!!

!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!

!!!!!!!!!!!!!!!!

!!!!

!!!!!!!!!!!!!!!!!!!!!!!!!!!!

!!!!!!!!!

!

!!!!!!!!!!!!!!!!!!!

!!!

!

!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!

!!!!!!!!!!!

!!!!!!!!

!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!

!!!!!!!!!!!!!!!!!!!!!!

!!!!A!A!A!A!A!A!A!A!A!A!A!A!A!A!A£101San Luis ObispoSan Luis RangePismo BeachSan Luis Obispo BayPrice Canyonstudy area boundaryIrish Hillsstudy area boundaryAvila BeachOld SeeCanyon 1Mello 2Bassi CoreHole 1HellerCoreHole 1Townsend-Gunter 1Townsend-Peterson 1SignalETS 1Rock 75Holmes 1Guidetti A1Guidetti A3Guidetti A7Guidetti A4ShellBeach 1Rock 11G S T 1 S T227£101^_CambriaPort San LuisSan Luis ObispoDCPPMap projection and scale: WGS 84 / UTM Zone 10N,1:80,000Figure extentLocation of Selected Oil Wellsand 2011 Seismic Reflection LinesEastern Irish Hills and San Luis RangeE2-2DCPP GEOLOGIC MAPPING PROJECT

+/-0 1 2mi.0 2 4kmEXPLANATION

!AHydrogeologic well

!AOil well!AOil well with sonic logWellsSeismic Reflection SurveyAWD lines 4+/-0 1,000 500 ft.500 250 0 mBase map: LiDAR-derived hillshade overlain by USGS topographic quadrangle map 00380 Spooner 1 Maino-Gonzales 1 00247 DOGGR database ArcGIS plot of well record (preferred)

Field location, 2013 (preferred) 00247EXPLANATIONPacific Gas and Electric CompanyFile Path: S:\1005\020\QA_GIS\Final_Figures\Figure_E2-03.ai; Date: 05/29/2014; User: Alex Remar Location of the Maino-Gonzales 1and Spooner 1 Wells Figure E2-3 DCPP GEOLOGIC MAPPING PROJECT File Path: S:\1005\020\QA_GIS\Final_Figures\Figure_E2-4.ai; Date: 05/29/2014; User: Alex RemarLocation of the Pecho 1 WellBase map: LiDAR-derived hillshade overlain by USGS topographic quadrangle map DOGGR database ArcGIS plot of well record Location of "Drill Hole" from USGS (preferred) 00310 00310EXPLANATION Pecho 1+/-0 1,000 500 ft.500 250 0 m Figure E2-4 DCPP GEOLOGIC MAPPING PROJECTPacific Gas and Electric Company File Path: S:\1005\020\QA_GIS\Final_Figures\Figure_E2-05.ai; Date: 05/29/2014; User: Alex RemarLocation of the Honolulu-Tidewater 1 Well 00477 Honolulu-Tidewater 1Base map: LiDAR-derived hillshade overlain by USGS topographic quadrangle map DOGGR database Field location, 2012 (preferred) 00477EXPLANATION

+/-0 1,000 500 ft.500 250 0 mPacific Gas and Electric Company Figure E2-5 DCPP GEOLOGIC MAPPING PROJECT File Path: S:\1005\020\QA_GIS\Final_Figures\Figure_E2-06.ai; Date: 05/29/2014; User: Alex RemarLocation of the Montadoro 1 WellBase map: LiDAR-derived hillshade overlain by USGS topographic quadrangle map 00478 DOGGR database ArcGIS plot of well record (preferred) 00478EXPLANATION Montadoro 1

+/-0 1,000 500 ft.500 250 0 mPacific Gas and Electric Company Figure E2-6 DCPP GEOLOGIC MAPPING PROJECT 4File Path: S:\1005\020\QA_GIS\Final_Figures\Figure_E2-07.ai; Date: 05/29/2014; User: Alex RemarLocation of the Sousa 1 WellBase map: LiDAR-derived hillshade overlain by USGS topographic quadrangle map 00581 Sousa 1 DOGGR database ArcGIS plot of well record (preferred) 00581EXPLANATION

+/-0 1,000 500 ft 500 250 0 mPacific Gas and Electric Company Figure E2-7 DCPP GEOLOGIC MAPPING PROJECT Pacific Gas and Electric CompanyFigure Note: Original data from dipmeter log, deviation log provided in Excel file.

Deviation of Honolulu-Tidewater 1 Well from Dipmeter Log E2-8 DCPP GEOLOGIC MAPPING PROJECTFile Path: S:\1005\020\QA_GIS\Final_Figures\Figure_E2-08.ai; Date: 05/29/2014; User: Alex Remar-12000-10000-8000-6000

-4000

-2000 00246810Depth (ft.) vInclination(deg.)-12000-10000-8000-6000-4000-2000 0090180270360Depth (ft.) vAzimuth (deg.)-12000-10000-8000

-6000-4000-2000 0-2000200East Drift (ft.)North Drift (ft.)

Depth (ft.)

Depth (ft.)

Depth (ft.)

Drift Distance (ft.)

Drift Aziumuth (deg.)

Drift Inclination (deg.)(a) Depth vs. Inclination(b) Depth vs. Azimuth (c) Depth vs. Drift Distance (Easting and Northing Components)

Pacific Gas and Electric Company Sonic Logs for Tar Springs 1A and Shell Beach 1 Wells File Path: S:\1005\020\QA_GIS\Final_Figures\Figure_E2-09.ai; Date: 05/29/2014; User: Alex Remar 0 500 1,000 1,500 2,000 2,500 3,000 3,500 Vp (fps) Vp ProfileTar Springs 1 A, API 07900671 0 500 1,000 1,500 2,000 2,500 3,000 3,500 4,000 4,500 5,000 5,500 0 5,000 10,000 15,000 20,000 25,000 0 5,000 10,000 15,000 20,000 Geologic Unit Geologic Unit Depth (feet)

Depth (feet)

Vp (fps) Vp Profile Shell Beach 1, API 07920594 Obispo Formation (volcanics)

Obispo, Rincon Shale? (sltstn, ss, sh)

Monterey Formation Santa Margarita Sandstone Fault zone?(soft sh, sltstn)

Obispo Fm.?(sandstone)

Obispo Formation (ss, sltstn, sh with dolomite)

Figure E2-9 DCPP GEOLOGIC MAPPING PROJECT Sonic Logs for Leroy F-7B and Rock 11G Wells File Path: S:\1005\020\QA_GIS\Final_Figures\Figure_E2-10.ai; Date: 05/29/2014; User: Alex RemarPacific Gas and Electric Company Figure E2-10 DCPP GEOLOGIC MAPPING PROJECT 0 0 500 1,000 1,500 2,000 Knoxville Formation Pismo Formation, Edna Member Vp (fps) Vp ProfileRock 11G, API 07921166 6,600 6,700 6,800 6,900 7,000 7,100 7,200 0 5,000 10,000 15,000 20,000 0 5,000 10,000 15,000 Vp (fps) Vp Profile Leroy F-7B, API 07920532 No data Geologic Unit Geologic Unit Depth (feet)

Depth (feet)

Sonic Logs for Guidetti A3 and Guidetti A4 Wells File Path: S:\1005\020\QA_GIS\Final_Figures\Figure_E2-11.ai; Date: 05/29/2014; User: Alex Remar Pismo Formation, Edna Member Geologic Unit Geologic Unit Monterey Formation Obispo FormationnoitamroF yeretnoMnoitamroF yeretnoM Miguelito Member Edna Member Pismo Formation 0 500 1,000 1,500 2,000 2,500 3,000 0 5,000 10,000 15,000 Vp (fps) Vp ProfileGuidetti A3, API 07920545 0 500 1,000 1,500 2,000 2,500 3,000 Fault?Fault?0 5,000 10,000 15,000 Depth (feet)

Depth (feet)

Vp (fps) Vp Profile Guidetti A4, API 07920566 Pacific Gas and Electric Company Figure E2-11 DCPP GEOLOGIC MAPPING PROJECT Sonic Logs for Offshore Wells P-0397-1 and P-0435-1 File Path: S:\1005\020\QA_GIS\Final_Figures\Figure_E2-12.ai; Date: 05/29/2014; User: Alex Remar 0.000 0.100 0.200 0.300 0.400 0.500 0.600 0.700 0.800 0.900 1.000 0 Geologic contacts Geologic contacts Time (seconds)

Vp (fps) Vp Profile Well P-0397-1 0.000 0.200 0.400 0.600 0.800 1.000 1.200 1.400 Early-late Pliocene unconformity Top of Miocene Fm.

Top of Knoxville Fm.

Top of Franciscan Complex Opal CT/Qtz transition Top of Monterey Fm.

Top of Miocene unconformity Top of Monterey Formation Top of Point Sal Fm.

Top of Obispo Fm.

Top of Franciscan Complex Bottom of hole 3,300 feet (1,006 m)

Bottom of hole 6,700 feet (2,043 m) 1.600 1.800 Source: Willingham et al. (2013)

Note: Y-axis units are travel times from seismic reflection data.

0 5,000 10,000 15,000 20,000 5,000 10,000 15,000 20,000 Time (seconds)

Vp (fps) Vp ProfileWell P-0435-1 Pacific Gas and Electric Company Figure E2-12 DCPP GEOLOGIC MAPPING PROJECT