ML14174A885
| ML14174A885 | |
| Person / Time | |
|---|---|
| Site: | Oconee |
| Issue date: | 06/23/2014 |
| From: | Division of Nuclear Materials Safety II |
| To: | |
| References | |
| 50-269/14-301, 50-270/14-301, 50-287/14-301 | |
| Download: ML14174A885 (81) | |
Text
FACILflY NAME:
2014-301 Section 8 REPORT NUMBER:
2014-301 FINAL RO WRITTEN EXAM CONTENTS:
Fina RO Written Exam (75 as given questions with changes made during administration annotated)
EReference Handouts Provided To Applicants f Answer Key Location of Electronic Files:
Submitted Venfied By:________________________
ES-401 Site-Specific RO Written Examination Form ES-401-7 Cover Sheet U.S. Nuclear Regulatory Commission Site-Specific RO Written Examination Applicant Information Name:
Date: 06/18/2014 Facility/Unit: Oconee Region:
I El II III El IV El Reactor Type: WE] CE El BW GE El Start Time:
Finish Time:
Instructions Use the answer sheets provided to document your answers. Staple this cover sheet on top of the answer sheets. To pass the examination, you must achieve a final grade of at least 80.00 percent. Examination papers will be collected 6 hours6.944444e-5 days <br />0.00167 hours <br />9.920635e-6 weeks <br />2.283e-6 months <br /> after the examination begins.
Applicant Certification All work done on this examination is my own.
I have neither given nor received aid.
Applicants Signature ResuIts Examination Value 75 Points Applicants Score Points Applicants Grade Percent
Oconee Nuclear Station 1LT45 ONS RO NRC Examination Question:
I (1 point)
Given the following Unit I conditions:
Reactor power = 100% stable 1) 1 RC-66 (PORV) will OPEN if the I RC-66 pilot valve solenoid is inadvertently (1) 2)
If I RC-66 fails OPEN and NO operator action is taken, the reactor will trip on (2)
RCS pressure A.
- 1. energized
- 2. Low B.
- 1. energized
- 2. Variable Low C.
- 1. de-energized
- 2. Low D.
- 1. de-energized
- 2. Variable Low Page 1 of 75
Oconee Nuclear Station ILT4S ONSRONRCExamination Question:
2 (1 point)
Given the following Unit I conditions:
Time = 1700 Reactor power = 100%
Time = 1701 Reactor tripped Time = 1706 RCS pressure = 425 psig slowly decreasing All SCM5 = 0°F and stable HPI header A flow = 478 gpm and stable IA and lB HPI pumps operating IC HPI pump breaker failed open Which ONE of the following describes what valve must be opened and what flow limit is in effect?
A.
Open I HP-409 and ensure total HPI flow is 950 gpm B.
Open I HP-409 and ensure total HPI flow is 750 gpm C.
Open I HP-410 and ensure total HPI flow is < 950 gpm D.
Open I HP-410 and ensure total HPI flow is 750 gpm Page 2 of 75
Oconee Nuclear Station ILT4S ONS RO NRC Examination Question:
3 (1 point)
Given the following Unit I conditions:
Initial conditions:
Time = 0400 Reactor power = 100%
Current conditions:
Time=0415 ISA-02/D-4 (RC PRESS EMERG LOW) actuated RCS pressure = 520 psig decreasing RB pressure = 2] psig increasing ONLY ES Channels I and 2 actuated
- 1) The HIGHER pressure that will result in a RCS Low Pressure reactor trip is (1)
(2)
Which ONE of the following completes the statements above?
A.
- 1. 1810 psig
- 2. ES Channels 3 through 6 trip push buttons must be depressed B.
- 1. 1810 psig
- 2. ONLY ES Channels 3 and 4 trip push buttons must be depressed C.
- 1. 1850 psig
- 2. ES Channels 3 through 6 trip push buttons must be depressed D.
- 1. 1850 psig
- 2. ONLY ES Channels 3 and 4 trip push buttons must be depressed Page 3 of 75
Oconee Nuclear Station 1LT45 ONSRONRCExamination Question:
4 (1 point)
Given the following Unit 2 conditions:
Reactor power 100%
2HP-31 (RCP Seal Flow Control) failed CLOSED ALL individual RCP seal return valves CLOSED 2CC-8 (CC Return Block) failed CLOSED
In accordance with 2AP/14 (Loss of HPI Normal Makeup and/or Seal Injection), the operator will be directed to trip the reactor and (2)
Which ONE of the following completes the statements above?
A.
- 1. remain OPEN
- 2. dispatch an operator to establish SSF RC Makeup B.
- 1. automatically CLOSE
- 2. dispatch an operator to establish SSF RC Makeup C.
1.
remain OPEN
- 2. immediately secure ALL RCPs D.
- 1. automatically CLOSE
- 2. immediately secure ALL RCPs Page 4 of 75
Oconee Nuclear Station ILT45 ONS RO NRCExamination Question:
5 (1 point)
Given the following Unit I conditions:
Initial conditions:
Reactor power = 100%
IHP-31 (RCP Seal Flow Control) failed CLOSED AP/14 (Loss of Normal HPI Makeup and/or RCP Seal Injection) initiated Current conditions:
IHP-31 has been repaired Seal injection flow is being re-established to the RCP seals
- 1) RCP seal injection flow is re-established slowly to prevent (1) 2)
In accordance with AP/14, (2) is/are throttled opened to re-establish RCP seal injection flow.
Which ONE of the following completes the statements above?
A.
- 1. water hammer and possible damage to the RCP thermal barrier
- 2. IHP-31 B.
- 1. water hammer and possible damage to the RCP thermal barrier
- 2. the individual RCP Seal Injection Throttle valves C.
- 1. prevent thermal shock and possible damage to the RCP seals
- 2. IHP-31 D.
- 1. prevent thermal shock and possible damage to the RCP seals
- 2. the individual RCP Seal Injection Throttle valves Pages of 75
Oconee Nuclear Station 1LT45 ONS RO NRC Examination Question:
6 (1 point)
Given the following Unit I conditions:
Initial conditions:
Heatup in progress LPI in High Pressure mode Current conditions:
ILP-12 (IA LPI Cooler Outlet) is inadvertently closed and will NOT open AP/26 (Loss of Decay Heat Removal) initiated
- 1) AP126 will direct aligning LPI in the (1)
Mode to restore RCS cooling.
- 2) When LPI flow is restored above, flow will be entering the reactor vessel via the (2)
Which ONE of the following completes the statements above?
A.
- 1. Switchover
- 2. A CFT nozzle ONLY B.
- 1. Switchover 2.
A and B CFT nozzles C.
- 1. Series
- 2. A CFT nozzle ONLY D.
- 1. Series
- 2. A and B CFT nozzles Page 6 of 75
Oconee Nuclear Station 1LT45 ONSRONRCExamination Question:
7 (1 point)
Given the following Unit I conditions:
Initial conditions:
Reactor power = 100%
IA and I B Letdown Coolers in service Current conditions:
IA Letdown Cooler is removed from service by the RO in the control room I) CC flowto the lB Letdown Coolerwill (I) 2)
If letdown temperature increases, control rods will (2) as a result of the reactivity change.
Which ONE of the following completes the statements above?
A.
- 1. stay the same
- 2. insert B.
- 1. stay the same
- 2. withdraw C.
- 1. increase
- 2. insert D.
I. increase
- 2. withdraw Page 7 of 75
Oconee Nuclear Station 1LT45 ONSRONRCExamination Question:
8 (1 point)
Given the following Unit I conditions:
Initial conditions:
Time =0400 Reactor power = 100%
Current conditions:
Time =0401 A transient occurs RCSpressuredecreasedto2l4l psig RCS pressure = 2142 psig slowly increasing Which ONE of the following lists ALL of the Pzr heater banks that are energized at 0401?
A.
BankIONLY B.
Banks 1 and 2 ONLY C.
Banks I and 3 ONLY D.
Banksl,2,3and4 Page 8 of 75
Oconee Nuclear Station 1LT45 ONSRONRCExamination Question:
9 (1 point)
Given the following Unit 1 conditions:
Initial conditions:
Time =0400 Reactor power = 100%
Current conditions:
Time =0405 ITA lockout occurs Reactor power = 90% decreasing ONLY one RO is currently in the Unit I horseshoe area
- 1. At 0405, the RO will be directed to perform (1)
- 2. When initiated, Rule 1 (2)_direct tripping the Main Turbine.
Which ONE of the following completes the statements above?
A.
- 1. Immediate Manual Actions
- 2. will B.
- 1. Immediate Manual Actions
- 2. will NOT C.
- 1. Rule I
- 2. will D.
- 1. Rule I
- 2. will NOT Page 9 of 75
Oconee Nuclear Station 1LT45 ONSRONRCExamination Question:
10 (1 point)
Given the following Unit I conditions:
Time = 0400 Reactor power = 100%
TDEFDWpumpisOOS Time = 0401 Both Main FDW pumps trip Loss of IA to 1 FDW-316 occurs Time = 0410 IA SG level = 27 inches XSUR increasing I B SG level = 36 inches XSUR increasing I)
At 0410, (1)
SG has indications ofa tube leak.
- 2) At 0410 and in accordance with Rule 7 (SG Feed Control) the MAXIMUM EFDW flow allowed to each SG is (2) gpm.
Which ONE of the following completes the statements above?
A.
1.IA
- 2. 600 B.
1.IA
- 2. 1000 C.
1.IB
- 2. 600 D.
1.IB
- 2. 1000 Page 10 of 75
Oconee Nuclear Station 1LT45 ONSRONRCExamination Question:
11 (1 point)
Given the following Unit I conditions:
Initial conditions:
Reactor power = 100%
Current conditions:
Total loss of Main and Emergency Feedwater LOHT tab in progress Rule 4 (Initiation of HPI Forced Cooling) initiated When Rule 4 is complete, (1)
RCP(s) and (2)
HPIP(s) will be operating.
Which ONE of the following completes the statement above?
A.
- 1. ONLYone
- 2. ONLYtwo B.
- 1. ONLYone
- 2. three C.
- 1. ONLY two
- 2. ONLY two D.
- 1. ONLYtwo
- 2. three Page 11 of75
Oconee Nuclear Station 1LT45 ONSRONRCExamination Question:
12 (1 point)
Given the following Unit I conditions:
Initial conditions:
Time = 0400 A station blackout has occurred Current conditions:
Time = 0730 I CA bus voltage = 105 VDC At 0730 and in accordance with the Blackout tab, I CC-8 (CC Return Block)
(1) required to be failed closed because it fails (2)
Which ONE of the following completes the statement above?
A.
1.isNOT
- 2. closed on a loss of IA B.
I.isNOT
- 2. closed on a loss of DC power C.
I.is
- 2. open on a loss of IA D.
1.is
- 2. open on a loss of DC power Page 12 of 75
Oconee Nuclear Station 1LT45 ONSRONRCExamination Question:
13 (1 point)
Given the following Unit 1 conditions:
Initial conditions:
Reactor power = 100%
Switchyard Isolation (LOOP) occurs Current conditions:
MFBs energized from Keowee AP/Il (Recovery From Loss of Power) Step 4.16 in progress Step 416 Place transfer switches (N/E) in MAN for all Oconee units receiving power from the normal source (IT, 2T, 3T).
- 1) ALoadShed (2) occurredonUniti.
- 2) The purpose for the above step is to (1) on a subsequent unit trip.
Which ONE of the following completes the statement above?
A.
1.
has 2.
prevent an out of sync rapid bus transfer B.
1.
has 2.
ensure a slow transfer does not occur C.
- 1. has NOT
- 2. prevent an out of sync rapid bus transfer D.
- 1. has NOT
- 2. ensure a slow transfer does not occur Page 13 of 75
Oconee Nuclear Station 1LT45 ONSRONRCExamination Question:
14 (1 point)
Given the following Unit I conditions:
Initial conditions:
Reactor power = 100%
SASS in MANUAL PZR level I selected Current conditions:
I KVIA de-energized
- 1) IHP-120 (RC Volume Control) will throttle (1)
- 2) The operator will select Pzr level (2) to restore a valid Pzr level.
Which ONE of the following completes the statements above?
A.
- 1. open
- 2. 2 B.
- 1. open
- 2. 3 C.
- 1. closed
- 2. 2 D.
- 1. closed
- 2. 3 Page 14 of 75
Oconee Nuclear Station 1LT45 ONSRONRCExamination Question:
15 (1 point)
Given the following plant conditions:
ICA Battery Charger fails
> Output voltage = 0 VDC 1CA Battery voltage = 120 VDC I DCB Bus voltage = 123 VDC Unit 2 DCAIDCB Bus voltage = 125 VDC Unit 3 DCAIDCB Bus voltage = 127 VDC Which ONE of the following will automatically supply power to IDIA panelboard?
A.
ICA Battery B.
Unit 3 DC Bus C.
1DCB Bus D.
Unit2DCBus Page 15 of 75
Oconee Nuclear Station 1LT45 ONSRONRCExamination Question:
16 (1 point)
Given the following Unit I conditions:
Initial conditions:
Reactor power = 100%
A and B LPSW pumps operating Current conditions:
A LPSW pump trips due to breaker failure Standby LPSW pump will NOT start AP124 (Loss of LPSW) initiated LPSW header pressure deceases to 15 psig and is now increasing
- 1) ILPSW-1121, 1122, 1123, and 1124 closed ate MAXIMUM LPSW header pressure of (2) psig decreasing 2)
In accordance with AP/24 the above valves are closed to (1)
Which ONE of the following completes the statements above?
A.
- 1. 18
- 2. prevent subsequent LPSW pump run out B.
- 1. 18
- 2. prevent water hammers in the LPSW system C.
1.25
- 2. prevent subsequent LPSW pump run out D.
1.25
- 2. prevent water hammers in the LPSW system Page 16 of 75
Oconee Nuclear Station 1LT45 ONSRONRCExamination Question:
17 (1 point)
Given the following Unit I conditions:
Initial conditions:
Reactor power = 100%
Current conditions:
IA Header pressure = 25 psig decreasing Aux IA Header pressure = 100 psig stable Letdown temperature = 131°F stable IHP-5 is (1) because (2)
Which ONE of the following completes the statement above?
A.
- 1. open 2.
it is backed up by Nitrogen B.
- 1. open 2.
it is backed up by Aux IA C.
- 1. closed 2.
- 1. closed 2.
it closed on high Letdown temperature Page 17 of 75
Oconee Nuclear Station 1LT45 ONSRONRCExamination Question:
18 (1 point)
Given the following Unit I conditions:
Reactor trip due to loss of Main Feedwater Emergency Feedwater is NOT available Condensate Booster Pump feed has been established RCS leak = 80 gpm slowly increasing Which ONE of the following describes:
- 1) actions required by the LOHT tab for RCPs?
- 2) the reason for the actions?
A.
I. Reduce to one pump per loop
- 2. To reduce heat input to RCS B.
- 1. Reduce to one pump per loop
- 2. To reduce inventory loss from the RCS C.
I. Reduce to ONLY one RCP
- 2. To reduce heat input to RCS D.
I. Reduce to ONLY one RCP
- 2. To reduce inventory loss from the RCS Page 18 of 75
Oconee Nuclear Station ILT4S ONSRONRCExamination Question:
19 (1 point)
Given the following Unit I conditions:
Initial conditions:
Reactor power = 100%
Current conditions:
Main Turbine has tripped Reactor power = 48% decreasing Rule I (ATWS/UNPP) in progress I HP-24 will NOT open 1)
In accordance with Rule 6, (HPI Pump Throttling Limits)
(1) 2)
In accordance with Rule 6, (HPI Pump Throttling Limits) the MAXIMUM reactor power which will allow throttling HPI is (2)
Which ONE of the following completes the statements above?
A.
- 1. throttle total HPI flow < 950 gpm (including seal injection)
- 2. 1%
B.
- 1. throttle total HPI flow 950 gpm (including seal injection)
- 2. <5%
C.
I. ONLY two HPI pumps are allowed to be operating
- 2. <1%
D.
I. ONLY two HPI pumps are allowed to be operating
- 2. 5%
Page 19 of 75
Oconee Nuclear Station 1LT45 ONSRONRCExamination Question:
20 (1 point)
Unit I plant conditions:
Reactor power = 100%
50 gpd Tube Leak An increase in activity is reported in Chemical Treatment Pond (CTP) #3 Which ONE of the following describes an RIA which if it indicated increasing counts could explain the source of the above increase?
A.
I RIA-42 (RCW)
B.
IRIA-31 (LPI Cooler)
C.
IRIA-54(TBS)
D.
1 RIA-33 (LW Release)
Page 20 of 75
Oconee Nuclear Station 1LT45 ONSRONRCExamination Question:
21 (1 point)
Given the following Unit I conditions:
Initial conditions:
Reactor power = 100%
Fire in Unit I Cable Room AP/50 (Challenging Plant Fire) has been initiated Current conditions:
AP/50, Section 4G (Unit I Control Room Evacuation) in progress
- 1) Section 4G will direct the OATC to (1)
- 2) The reason the above action is taken is to take (2)
Which ONE of the following completes the statements above?
A.
- 1. 1FDW-315 and IFDW-316 to MANUAL and close
- 1. IFDW-315 and 1FDW-316 to MANUAL and close
- 2. prevent spurious operation of I FDW-315 and IFDW-316 due to fire damage C.
1.
1A and I B TBVs to MANUAL and control SG pressure from the ADVs
- 2. ensure natural circulation develops when the RCPs are secured D.
- 2. maximize SG inventory prior to losing secondary pumps due to the fire Page 21 of 75
Oconee Nuclear Station 1LT45 ONSRONRCExamination Question:
22 (1 point)
Given the following Unit I conditions:
Initial conditions:
Time =0400 Reactor power = 100%
ISA3/B6 (FIRE ALARM) actuated The BOP reviews the alarms at the Fire Alarm Control panel Current conditions:
Time=0415 Fire detector at the Unit I Main FDW pumps alarms
- 1) At 0400, the alarm at the Fire Alarm Control panel will be indicated by (1)
- 2) At 0415, ISA3IB6 (Fire Alarm)
(2)_ reflash.
Which ONE of the following completes the statements above?
A.
- 1. a blinking LED ONLY
- 2. will B.
- 1. a blinking LED ONLY
- 2. will NOT C.
- 1. a blinking LED g an audible alarm
- 2. will D.
- 1. a blinking LED an audible alarm
- 2. will NOT Page 22 of 75
Oconee Nuclear Station 1LT45 ONSRONRCExamination Question:
23 (1 point)
Given the following Unit 3 conditions:
Time = 0400 AP/8 (Loss of Control Room) initiated Control Room Evacuation complete due to a non-fire event ASDP has been manned ASDP indications:
Turbine Header Pressure = 1011 psig and slowly decreasing TBVs demand is 12% in Automatic and decreasing RCS T Hot = 560°F and slowly decreasing Pzr Level = 140 inches increasing SG SU levels = 48 inches and increasing ALL RCPs are operating At 0400, which ONE of the following describes the required action(s) (if any) per AP/8 and why?
A.
NO actions are required, the plant is responding as expected.
B.
Take manual control of TBVs to stabilize SG Pressure.
C.
Take manual control and cycle 3B HPI pump to stabilize Pzr level.
D.
Take manual control of FDW Startup Control Valves and lower SG levels.
Page 23 of 75
Oconee Nuclear Station 1LT45 ONSRONRCExamination Question:
24 (1 point)
Given the following Unit I conditions:
Reactor Power = 36%
I RIA-40 Alert and High Alarm actuated Letdown Flow 78 gpm Seal Inlet Header flow = 32 gpm RC Makeup flow = 85 gpm RCP Seal Return Flows:
> IAI=2.Igpm
> 1A2=2.2gpm
> 1BI=2.lgpm
> 1B2=2.lgpm Pressurizer level = 220 inches stable 1)
(1) is required to be entered at this time.
- 2) The procedure entered above will direct maintaining a Pzr level band of (2)
Which ONE of the following completes the statements above?
A.
- 2. 140 inches 180 inches B.
- 2. 220 inches 260 inches C.
I. AP/3I (Primary to Secondary Leakage)
- 2. 140 inches 180 inches D.
- 1. AP/31 (Primary to Secondary Leakage)
- 2. 220 inches 260 inches Page 24 of 75
Oconee Nuclear Station 1LT45 ONSRONRCExamination Question:
25 (1 point)
Given the following Unit I conditions:
Initial conditions:
Reactor power = 25% slowly increasing Turbine trip Current conditions:
Reactor power = 22% decreasing 1)
(1) will be used to direct plant activities after the Turbine trip.
- 2) The expected Steam Generator pressure is (2) psig.
Which ONE of the following completes the statements above?
A.
- 1. TheUNPPtab
- 2. 885 B.
I. TheUNPPtab
- 2. 1010 C.
- 1. AP/1 (Unit Runback)
- 2. 885 D.
- 1. AP/1 (Unit Runback)
- 2. 1010 Page 25 of 75
Oconee Nuclear Station 1LT45 ONSRONRCExamination Question:
26 (1 point)
Given the following Unit I conditions:
Turbine Building Flood (TBF) tab initiated Main and Emergency Feedwater have been lost I)
In accordance with the TBF tab RCS decay heat will be removed using (I)
- 2) This heat removal method is chosen because (2)
Which ONE of the following completes the statements above?
A.
- 1. HPI Forced Cooling
- 2. Raw lake water will damage the SGs B.
I. HPI Forced Cooling
I. SSF-ASW
- 2. of anticipation of losing Condensate Booster Pumps D.
I. SSF-ASW
- 2. of anticipation of losing LPSW pumps Page 26 of 75
Oconee Nuclear Station ILT4S ONSRONRCExamination Question:
27 (1 point)
Given the following Unit I conditions:
C0reSCM=0°F LOCA CooIdown tab in progress CETCs = 395°F slowly decreasing I)
In accordance with the LOCA CD tab (I) is required to be opened to establish the normal Boron dilution flow path.
- 2) The above valve will be operated from the (2)
Control Room Which ONE of the following completes the statements above?
A.
- 2. Unit I B.
1.
1 LP-1 03 (Post LOCA Boron Dilute)
- 2. SSF C.
I.
I LP-1 05 (Post LOCA Boron Dilute To LPI Suction)
- 2. Unit I D.
1.
1 LP-1 05 (Post LOCA Boron Dilute To LPI Suction)
- 2. SSF Page 27 of 75
Oconee Nuclear Station 1LT45 ONSRONRCExamination Question:
28 (1 point)
Given the following Unit 1 conditions:
Initial conditions:
Time =0400:00 Reactor power = 100%
I BI RCP Amps = 527 Current conditions:
Time =0400:01 1B1 RCPAmps=255 Reactor power will (1) and feedwater will (2)
Which ONE of the following completes the statement above?
A.
- 1. decrease
- 2. re-ratio B.
- 1. decrease
- 2. NOT re-ratio C.
- 1. staythesame
- 2. re-ratio D.
- 1. staythesame
- 2. NOT re-ratio Page 28 of 75
Oconee Nuclear Station 1LT45 ONSRONRCExamination Question:
29 (1 point)
Given the following Unit I conditions:
Initial conditions:
Time = 0400 Reactor power = 15%
Current conditions:
Time = 0430 RCS temperature = 535 °F decreasing RCS pressure = 2040 psig decreasing Pzr level = 200 inches decreasing LDST level = 65 inches decreasing
- 1) The HIGHER LDST level that will automatically align the HPI pumps suction to the BWST is (1) inches.
- 2) At 0430, the reactor (2) automatically tripped on low RCS pressure.
Which ONE of the following completes the statements above?
A.
- 1. 58
- 2. has B.
1.58
- 2. has NOT C.
1.38
- 2. has D.
1.38
- 2. has NOT Page 29 of 75
Oconee Nuclear Station 1LT45 ONSRONRCExamination Question:
30 (1 point)
Given the following Unit I conditions:
Reactor in MODE 5 LPI is aligned in the Normal Decay Heat Removal flowpath I) Aligning LPI to the Purification Demineralizers (I) require the use of pneumatic valves.
Which ONE of the following completes the statements above?
A.
I. does
- 2. is B.
- 1. does
- 2. is NOT C.
I. does NOT
- 2. is D.
I. does NOT
- 2. is NOT Page 30 of 75
Oconee Nuclear Station 1LT45 ONSRONRCExamination Question:
31 (1 point)
Given the following Unit 3 plant conditions:
Reactor in MODE 5 LPI in normal DHR alignment (1) temperatures will be used to ensure compliance with Tech Spec allowed cooldown rates and (2) will be used to adjust cooldown rate.
Which ONE of the following completes the statement above?
A.
- 1. LPI Cooler Outlet
- 2. LPSW flow B.
- 1. LPI Cooler Outlet
- 2. LPI flow C.
- 2. LPSW flow D.
- 2. LPI flow Page 31 of 75
Oconee Nuclear Station 1LT45 ONSRO NRC Examination Question:
32 (1 point)
Given the following Unit I conditions:
RCS cooldown in progress RCS pressure = 1780 psig slowly decreasing The HPI ES bypass permissive is activated at a MAXIMUM RCS pressure of (1) psig and (2) require manual actions to be re-instated when RCS pressure is returned to normal operating pressure.
Which ONE of the following completes the statement above?
A.
- 1. 1715
- 2. will B.
- 1. 1715
- 2. will NOT C.
- 1. 1740
- 2. will D.
- 1. 1740
- 2. will NOT Page 32 of 75
Oconee Nuclear Station 1LT45 ONSRONRCExamination Question:
33 (1 point)
Given the following Unit I conditions:
Initial conditions:
Reactor power = 100%
Current conditions:
ES Channels 1 8 actuated EOP Enclosure 5.1 (ES Actuation) initiated HPI Flow Train A = 520 gpm HPI Flow Train B = 468 gpm RCMakeUpFlow=l6Ogpm Seal Inlet Header Flow = 32 gpm In accordance with the EOP, is/are required to be throttled to prevent HPI pump runout.
Which ONE of the following completes the statement above?
A.
1 HP-26 ONLY B.
1 HP-27 ONLY C.
1 HP-26 and 1 HP-27 D.
NOvalve Page 33 of 75
Oconee Nuclear Station 1LT45 ONSRONRCExamination Question:
34 (1 point)
Given the following Unit I conditions:
OP/i/All 1 03/002, (Filling and Venting RCS) Enclosure 4.14 (Establishing Pzr Steam Bubble And RCS Final Vent) in progress Quench Tank level = 82 inches Quench Tank pressure = 0.5 psig The Pressurizer is vented to the Quench Tank for 30 minutes Which ONE of the following describes QT parameters that would indicate that Pzr Steam Bubble Formation is complete?
QT level (inches)
QT pressure (psig)
A.
82.1 0.6 B.
84.1 0.6 C.
82.1 2.5 D.
84.1 2.5 Page 34 of 75
Oconee Nuclear Station ILT45 ONS RO NRC Examination Question:
35 (1 point)
Which ONE of the following will result in the Standby Component Cooling pump receiving an automatic start signal?
A.
CC Total Flow = 568 gpm B.
CRD Outlet HDR Flow = 136 gpm C.
Component Cooling system pressure = 95 psig D.
ONE Main Feeder Bus de-energized for 21 seconds Page 35 of 75
Oconee Nuclear Station 1LT45 ONSRONRCExamination Question:
36 (1 point)
Given the following Unit I conditions:
BWST Temperature = 85°F LDST Temperature = 105°F RCS pressure = 685 psig PZR level = 235 inches stable
- 1) The (1) is an allowable suction source for Auxiliary Pressurizer Spray.
- 2) The reason for the applicable limit in accordance with SLC 16.5.8 (Pressurizer) is to reduce (2)
Which ONE of the following completes the statements above?
A.
- 1. LDSTONLY
- 2. reduce thermal stress on the Pzr spray nozzle B.
- 1. LDSTortheBWST
- 2. reduce thermal stress on the Pzr spray nozzle C.
- 1. LDST ONLY
- 2. prevent exceeding the high Pzr level limit D.
- 1. LDST or the BWST
- 2. prevent exceeding the high Pzr level limit Page 36 of 75
Oconee Nuclear Station 1LT45 ONSRONRCExamination Question:
37 (1 point)
Given the following Unit I conditions:
Initial conditions:
Reactor power = 100%
IRC-1 failed OPEN RCS pressure = 2150 psig decreasing AP/44 (Abnormal Pressurizer Pressure Control) initiated Current conditions:
IRC-3 failed OPEN
- 1) RCSpressurewill (1)
- 2) AP/44 will initially direct stopping the (2) to help mitigate the failure.
Which ONE of the following completes the statements above?
A.
- 1. continue to decrease below the reactor trip setpoint 2, 1AIRCPONLY B.
- 1. continue to decrease below the reactor trip setpoint
- 2. IAI and 1A2 RCP C.
- 1. be maintained above the reactor trip setpoint
- 2. IAI RCP ONLY D.
- 1. be maintained above the reactor trip setpoint
- 2. IAI and 1A2 RCP Page 37 of 75
Oconee Nuclear Station 1LT45 ONSRONRCExamination Question:
38 (1 point)
Which ONE of the following would result in a trip of the ID RPS Channel AND the ID CRD Breaker?
A.
I D RPS channel Manual Trip keyswitch is placed in the trip position B.
Reactor Building Pressure Switch in the ID RPS channel fails OPEN C.
Loss of I DCB panelboard D.
Loss of the IKVID panelboard Page 38 of 75
Oconee Nuclear Station 1LT45 ONSRONRCExamination Question:
39 (1 point)
Given the following Unit 1 conditions:
Reactor power = 100%
1A RPS Thot RTD fails HIGH Which ONE of the following describes:
- 1) ALL RPS trips affected by the failure?
- 2) the action preferred, in accordance with OP/I/All 105/0 14 (Control Room Instrumentation Operation And Information)?
A.
- 1. RCS High Outlet Temperature ONLY
- 2. Place MANUAL TRIP Keyswitch in TRIP.
B.
- 1. RCS High Outlet Temperature ONLY
C.
- 2. Place MANUAL TRIP Keyswitch in TRIP.
D.
Page 39 of 75
Oconee Nuclear Station 1LT45 ONSRONRCExamination Question:
40 (1 point)
Given the following Unit I conditions:
Main Steam Line break inside the Reactor Building RCS pressure decreased to 974 psig and is now increasing Reactor Building pressure increased to 34 psig and is now decreasing Which ONE of the following lists ALL ECCS systems that have actuated?
A.
HPI ONLY B.
HPI AND Core Flood ONLY C.
HPIAND LPI ONLY D.
HPI, LPI, AND Core Flood Page 40 of 75
Oconee Nuclear Station 1LT45 ONSRONRCExamination Question:
41 (1 point)
Given the following Unit 3 conditions:
Initial conditions:
Time =0400 Reactor power = 100%
3A HPI Pump operating Current conditions:
Time =0401 Reactor tripped due to SBLOCA ES Digital Channels 2, 4, and 6 failed to automatically actuate At 0405, which ONE of the following lists only safety related components that will be in their ES condition?
ASSUME NO OPERATOR ACTIONS A.
KHU#2 / 3HP-5 B.
3BHPIPump /3PR-10 C.
KHU #2 / 3A LPI Pump D.
3B HPI Pump / 3LPSW-24 Page 41 of 75
Oconee Nuclear Station 1LT45 ONSRONRCExamination Question:
42 (1 point)
Given the following Unit I conditions:
Initial conditions:
Reactor power = 50% stable Current conditions:
LBLOCA occurs ITO de-energized Which ONE of the following describes the status of the below listed Reactor Building Cooling Units five (5) minutes after ES actuates?
ASSUME NO OPERATOR ACTIONS IARBCU IBRBCU A.
LOW LOW B.
LOW OFF C.
OFF LOW D.
OFF OFF Page 42 of 75
Oconee Nuclear Station 1LT45 ONSRONRCExamination Question:
43 (1 point)
Given the following plant conditions:
SBLOCA has occurred on Unit I Reactor Building Pressure = 11.2 psig slowly decreasing Unit 2 Reactor Power = 100%
Which ONE of the following describes the actions directed by Enclosure 5.1 (ES Actuation) to ensure the required LPSW flow exists in the IA LPI cooler?
A.
Place ILPSW-251 in FAIL OPEN ONLY B.
Place ILPSW-251 in FAIL OPEN AND fully open ILPSW-4 C.
Place I LPSW-251 in FAIL OPEN AND Throttle LPSW flow to approximately 3000 gpm using I LPSW-4 D.
Place I LPSW-251 in FAIL OPEN AND Throttle LPSW flow to approximately 5200 gpm using I LPSW-4 Page 43 of 75
Oconee Nuclear Station ILT45 ONS RO NRC Examination Question:
44 (1 point)
Given the following Unit I conditions:
Initial conditions:
Reactor power = 75% stable Current conditions:
1ATBVsfaiIOPEN 1)
(1) will be used to mitigate this event.
- 2) Reactor power will increase and then stabilize at (2)
Which ONE of the following completes the statements above?
A.
- 1. OP/1/A11106/OO1 (Turbine Generator)
- 2. a higher power slightly above pre-transient value B.
- 1. OPIIIAI1IO6IOOI (Turbine Generator)
- 2. approximately the pre-transient value C.
- 1. AP/11A117001028 (ICS Instrument Failures)
- 2. a higher power slightly above pre-transient value D.
- 1. AP/11A11700/028 (ICS Instrument Failures)
- 2. approximately the pre-transient value Page 44 of 75
Oconee Nuclear Station 1LT45 ONSRO NRC Examination Question:
45 (1 point)
Given the following Unit 3 conditions:
Time = 0400 Reactor power = 70% stable 3B2 RCP trips At 0430, which ONE of the following describes the response in FDW pump suction flows that has occurred over the previous 30 minutes?
A.
3A FDW Pump suction flow has increased AND 3B FDW Pump suction flow has decreased B.
3B FDW Pump suction flow has increased AND 3A FDW Pump suction flow has decreased C.
3A AND 3B FDW Pump suction flows have decreased D.
3A AND 3B FDW Pump suction flows remain unchanged Page 45 of 75
Oconee Nuclear Station ILT4S ONSRONRCExamination Question:
46 (1 point)
Given the following Unit I conditions:
Initial conditions:
Unit cooldown in progress IA and lB MD EFDWPs operating EOP Enclosure 5.9 (Extended EFDW Operation) in progress Current conditions:
UST level = 3.5 feet decreasing In accordance with EOP Enclosure 5.9, I) both MD EFDWPs are required to be secured at the HIGHER UST level of less than (I)
- 2) vacuum is (2) to be broken prior to the MD EFDWPs taking suction on the Hotwe II.
Which ONE of the following completes the statements above?
A.
- 1. one foot
- 2. required B.
I. one foot
- 2. NOT required C.
- 1. one inch
- 2. required D.
I. one inch
- 2. NOT required Page 46 of 75
Oconee Nuclear Station ILT4S ONS RO NRC Examination Question:
47 (1 point)
Given the following Unit 1 conditions:
Initial conditions:
Reactor power = 100%
1 DCA Bus Voltage = 125 VDC 1 DCB Bus Voltage = 126 VDC 2DCA Bus Voltage = 127 VDC 2DCB Bus Voltage = 127 VDC Current conditions:
IXSI incoming feederbreakertrips Based on the current conditions, which ONE of the following is correct regarding the DC power systems?
ASSUME NO OPERATOR ACTIONS A.
I DCA will be powered from the standby charger B.
1DCB loads will be powered from Battery 1CB C.
I KX Inverter will be powered from I DCB D.
I DIC lnverter will be powered from 1 DCB Page 47 of 75
Oconee Nuclear Station 1LT45 ONSRONRCExamination Question:
48 (1 point)
- 1) 600 volt MCC IXS2 is normally powered from a power string that begins at4 KVswitchgear (1) 2)
If the normal power supply to 1XS2 is lost, the alternate power supply (2) automatically energize IXS2.
Which ONE of the following completes the statements above?
A.
1.1TD 2.will B.
1.1TD
- 2. will NOT C.
1.1TE
- 2. will D.
1.1TE
- 2. will NOT Page 48 of 75
Oconee Nuclear Station 1LT45 ONSRONRCExamination Question:
49 (1 point)
Given the following station conditions:
Initial conditions:
All three units Reactor power = 100%
Current conditions:
All Units 4160v Main Feeder Busses are de-energized Unit 1, 2, and 3 EOP Blackout tabs in progress Which ONE of the following describes the required status of Unit I Essential Inverters per EOP Enclosure 5.38 (Restoration of Power) and why?
Unit ls Essential Inverters A.
remain energized to provide power to ES channels B.
remain energized to provide control power to 4160v C.
are de-energized to prevent inverter damage D.
are de-energized to extend the life of available batteries Page 49 of 75
Oconee Nuclear Station 1LT45 ONSRONRCExamination Question:
50 (1 point)
Given the following Unit 1 conditions:
Initial conditions:
Time =0400 Reactor power 100%
SLlandSL2closed ACB-4 closed Current conditions:
Time
= 0401 RCS pressure = 200 psig decreasing Switchyard Isolation occurs KeoweeUnit2 Emergency Locked out IA and 1 B LPI pumps will be_
Which ONE of the following completes the statement above?
A.
manually energized from CT-5 B.
automatically energized from CT-5 C.
manually energized from Keowee Unit 1 D.
automatically energized from Keowee Unit 1 Page 50 of 75
Oconee Nuclear Station 1LT45 ONSRONRCExamination Question:
51 (1 point)
Given the following Unit I conditions:
Initial conditions:
Time=1200 Reactor power = 35% stable IA steam generator tube leak = 2.1 gpd stable RCS activity = 0.25 pCi/mI DEl increasing Current conditions:
Time=1400 NO change in IA SG tube leak rate RCS activity = 0.65 pCi/mI DEl and increasing Which ONE of the following describes the response of the radiation monitors between 1200 and 1400?
A.
IRIA-16 (Main Steam Line Monitor) AND IRIA-40 (CSAE Off-gas) increase.
B.
IRIA-16 (Main Steam Line Monitor) increased while IRIA-40 (CSAE Off-gas) remain constant.
C.
I RIA-59 (N-16 monitor) AND 1 RIA-40 (CSAE Off-gas) increase.
D.
IRIA-59 (N-16 monitor) increased whilelRlA-40 (CSAE Off-gas) remain constant.
Page 51 of 75
Oconee Nuclear Station 1LT45 ONSRONRCExamination Question:
52 (1 point)
Given the following Unit I and 2 conditions:
Initial conditions:
A & B LPSW pump operating Current conditions:
ISA9/A9 LPSW HEADER A PRESS LOW A LPSW pump amps = 15
- 35 fluctuating B LPSW pump amps = 55 stable LPSW HDR PRESS = rapidly fluctuating between 60 & 75 psig
- 1) The A LPSW pump (1)
- 2) AP/24 (Loss of LPSW) will direct (2)
Which ONE of the following completes the statements above?
A.
- 1. is cavitating
- 2. placing the Unit 1/2 STANDBY LPSW PUMP AUTO START CIRCUIT in DISABLE then stopping LPSW Pump A and starting LPSW Pump C B.
- 1. hasa sheared shaft
- 2. placing the Unit 1/2 STANDBY LPSW PUMP AUTO START CIRCUIT in DISABLE then stopping LPSW Pump A and starting LPSW Pump C C.
- 1. iscavitating
- 1. hasa sheared shaft
Oconee Nuclear Station 1LT45 ONSRONRCExamination Question:
53 (1 point)
Given the following Unit 1 conditions:
Initial conditions:
Time =0400 Reactor power = 100%
Current conditions:
Time=0415 RCS pressure = 248 psig decreasing
- 1) At 0415, (1)
LPSW pumps will be supplying loads on Unit 1.
- 2) The B LPSW pump is powered from (2)
Which ONE of the following completes the statements above?
A.
- 1. ONLY two
- 2. lTD ONLY B.
- 1. ONLYtwo
- 2. 1TDor2TD C.
- 1. three
- 2. lTD ONLY D.
- 1. three
- 2. ITDpj2TD Page 53 of 75
Question:
54 (1 point)
Oconee Nuclear Station 1LT45 ONS RO NRC Examination Given the following plant conditions:
Large IA leak occurs Service air header pressure = 87 psig decreasing Turbine Building air header pressure per gage below:
Which ONE of the following describes the air compressors that will be operating?
The Primary IA Compressor AND...
A.
Diesel Air Compressors ONLY B.
Diesel Air Compressors AND AlA Compressors C.
AlA Compressors AND Backup IA Compressors D.
Backup IA Compressors ONLY Page 54 of 75
Oconee Nuclear Station 1LT45 ONSRONRCExamination Question:
55 (1 point)
Given the following Unit I conditions:
Initial conditions:
Time =0400 Reactor power = 100%
Current conditions:
Time=0415 RCS pressure = 1500 psig decreasing RB pressure = 1.2 psig increasing EOP Enclosure 5.1 (ES Actuation) initiated
- 1) At 0415, ILPSW-l5is (1) 2)
If closed due to ES actuation and in accordance with Enclosure 5.1, prior to opening I LPSW-1 5, the associated (2)
Which ONE of the following completes the statements above?
A.
- 1. open
- 2. voter is taken to override B.
- 1. open
- 2. ES channel(s) is/are taken to manual C.
- 1. closed
- 2. voter is taken to override D.
- 1. closed
- 2. ES channel(s) is/are taken to manual Page 55 of 75
Oconee Nuclear Station 1LT45 ONSRONRCExamination Question:
56 (1 point)
Given the following Unit I conditions:
Time = 0400 Reactor trip from 100% power due to a loss of offsite power Forced Cooldown (FCD) tab in progress Tcold = 550°F stable Time = 0500 RCS pressure = 2155 psig stable A Natural Circulation cooldown is initiated I RC-1 59 (RX Vessel Head Vent) will NOT open
- 1) At 0400 and in accordance with the FCD tab, the MAXIMUM allowable cooldown rate is (2)
- 2) During the cooldown, Reactor Vessel head voids (1) expected to occur.
Which ONE of the following completes the statements above?
A.
- 1. <50°F/hr
- 2. are B.
- 1. <50°F/hr
- 2. are NOT C.
- 1. 50°F/
1
,4hr
- 2. are D.
- 1. 50°F/%hr
- 2. are NOT Page 56 of 75
Oconee Nuclear Station 1LT45 ONS RO NRC Examination Question:
57 (1 point)
Given the following Unit 1 conditions:
Initial conditions:
A LOCA occurs from 100% power Multiple equipment failures have occurred Current conditions:
LOCA CD tab in progress A significant increase is noted on the Source Range
- 1) Atransferto the ICC tab is required (2)
- 2) A possible cause for the increase of the Source Range is significant voiding in the (1)
Which ONE of the following completes the statements above?
A.
- 1. when ANY SCM indicates superheat
- 2. core B.
- 1. when ANY SCM indicates superheat
- 2. downcomer C.
- 1. ONLY when the Core SCM indicates superheat
- 2. core D.
- 1. ONLY when the Core SCM indicates superheat
- 2. downcomer Page 57 of 75
Oconee Nuclear Station 1LT45 ONSRONRCExamination Question:
58 (1 point)
Given the following Unit I conditions:
Reactor power = 100%
Which ONE of the following completes the statements above?
A.
1.lKl
- 2. IKU B.
1.IKI
- 2. IKX C.
1.1KU
- 2. lKl D.
1.IKU
- 2. IKX Page 58 of 75
Oconee Nuclear Station ILT4S ONSRONRCExamination Question:
59 (1 point)
Given the following Unit 1 conditions:
Refueling in progress RB Purge in operation 1)
If the RB Main Purge fan trips due an RIA alarm, Spent Fuel Pool level will (1)
- 2) When the RB Main Purge fan trips above, PR valves (2) will automatically close.
Which ONE of the following completes the statements above?
A.
- 1. increase
- 2. 2 through 5 ONLY B.
- 1. increase 2.
1 through 6 C.
- 1. decrease
- 2. 2through5ONLY D.
- 1. decrease 2.
1 through 6 Page 59 of 75
Oconee Nuclear Station 1LT45 ONSRONRCExamination Question:
60 (1 point)
Given the following plant conditions:
Initial conditions:
Time=0400 A SFP pump operating Current conditions:
Time=0401 Spent Fuel Storage Cask has been dropped in Unit 1&2 SFP Spent Fuel damage is visible RA-6 and RIA-41 HIGH alarms actuate Spent Fuel Pool level = -3.5 feet decreasing
- 1) The Unit (1)
Reactor Building Purge filters will be used to reduce off site releases.
- 2) At 0401 the A SEP pump is (2)
Which ONE of the following completes the statements above?
A.
1.1 2.ON B.
1.1
- 2. OFF C.
1.2 2.ON D.
1.2
- 2. OFF Page 60 of 75
Oconee Nuclear Station 1LT45 ONSRONRCExamination Question:
61 (1 point)
Given the following Unit I conditions:
Reactor power 100%
ISA-02/B-1 1 (ICS AUTO POWER FAILURE)
As a result of the above failure:
- 1) IHP-120 (RC Volume Control) is operable in (1)
- 2) The Turbine Bypass Valves are operable in (2)
Which ONE of the following completes the statements above?
A.
- 1. HAND ONLY
- 2. HAND orAUTO B.
- 1. HAND ONLY
- 2. HAND ONLY C.
- 1. HAND orAUTO
- 2. HAND orAUTO D.
- 1. HAND orAUTO
- 2. HAND ONLY Page 61 of 75
Oconee Nuclear Station 1LT45 ONS RO NRC Examination Question:
62 (1 point)
Given the following Unit 1 conditions:
Time = 1200:00 Reactor power = 80% stable IA and I B CBP operating Time = 1201:00 lACBPtrips Feedwater Pump suction pressure = 225 psig slowly decreasing Time = 1203:00 Feedwater Pump suction pressure = 220 slowly increasing Which ONE of the following describes the:
- 1) runback rate (%/min) inserted at 1201 :00 to ICS?
- 2) procedure that will be directed by the Procedure Director at 1203:00?
A.
1.25
- 2. AP/1 IA/I 700/001 (Unit Runback)
B.
1.25
- 2. EOP C.
1.20
- 2. AP/1/A11700/001 (Unit Runback)
D.
1.20
- 2. EOP Page 62 of 75
Oconee Nuclear Station 1LT45 ONSRONRCExamination Question:
63 (1 point)
Given the following Unit I conditions:
Initial conditions:
Reactor power = 75% stable Diamond and BOTH FDW Masters in MANUAL Current conditions:
Reactor power = 63% decreasing Control Rod Group 5 Rod 6 Asymmetric Alarm light on the P1 panel is lit Control Rod Group 5 Rod In Limit light on the P1 panel is lit Asymmetric Fault light on Diamond Panel is lit
- 1) The Asymmetric Alarm light indicates that the rod is misaligned from the group averagebyaMiNiMUMof (1) inches.
2)
In accordance with AP/1 (Plant Runback), a MANUAL power reduction (2) required.
Which ONE of the following completes the statements above?
A.
1.7
- 2. is B.
1.7
- 2. is NOT C.
1.9
- 2. is D.
1.9
- 2. is NOT Page 63 of 75
Oconee Nuclear Station 1LT45 ONSRONRCExaminaiion Question:
64 (1 point)
Given the following Unit I conditions:
A unit shutdown is in progress due to a primary to secondary leak Reactor power = 32% decreasing 1)
(1) provides the operator with a readout in GPM.
- 2) At this time, the above RIA (2) procedurally allowed to be used to determine the primary to secondary leak rate.
Which ONE of the following completes the statements above?
A.
- 1. IRIA-16 (Main Steam Line Monitor)
- 2. is B.
- 1. IRIA-16 (Main Steam Line Monitor)
- 2. is NOT C.
- 1. IRIA-59 (N-16 monitor)
- 2. is D.
- 1. IRIA-59 (N-16 monitor)
- 2. is NOT Page 64 of 75
Oconee Nuclear Station 1LT45 ONSRONRCExamination Question:
65 (1 point)
Given the following Unit 2 conditions:
Initial conditions:
Reactor power = 100%
A and B LPSW pumps operating Switchyard Isolate occurs Current conditions:
Unit 2 MFB I & 2 energized
- 1) Unit I & 2 LPSW is supplied via the ECCW (1)
- 2) A and B LPSW pumps will restart (2) after power is restored.
Which ONE of the following completes the statements above?
A.
- 1. flrstsiphon
- 2. immediately B.
- 1. second siphon
- 2. immediately C.
- 1. first siphon
- 2. 10 seconds D.
- 1. second siphon
- 2. 10 seconds Page 65 of 75
Oconee Nuclear Station 1LT45 ONSRONRCExamination Question:
66 (1 point)
Given the following Unit I conditions:
B Shift is on duty The OATC asks to be temporarily relieved to go to the canteen.
The BOP has previously received a formal turnover on the unit.
Which ONE of the following describes whose permission is required to turn over the OATC position to the BOP and items that are required to be included in the turnover per OMP 2-01 (Duties and Responsibilities of On-Shift Operations Personnel)?
A.
Unit I Control Room SRO I review of Ops Guides and outstanding R&Rs B.
Unit I Control Room SRO I review RCS temperature/pressure and operating band C.
Any B shift SRO / review of Ops Guides and outstanding R&Rs D.
Any B shift SRO
/ review RCS temperature/pressure and operating band Page 66 of 75
Oconee Nuclear Station 1LT45 ONSRONRCExamination Question:
67 (1 point)
Given the following Unit I conditions:
Time = 0400 Generator output = 850 MWe stable Generator Hydrogen pressure = 50 psig stable Time = 0500 Generator output = 600 MWe stable Generator Hydrogen pressure = 30 psig stable I) At 0500 and in accordance with OP/I/NI 106/001 End. 4.5 (Capability Curve), the MAXIMUM MVARs allowed is approximately (I) 2)
If needed, MVARs can be changed by using the (2)
Which ONE of the following completes the statements above?
REFERENCE PROVIDED A.
- 1. 340
- 2. Voltage Adjuster (AUTO)
B.
- 1. 340
- 2. Turbine Speed Changer C.
- 1. 370
- 2. Voltage Adjuster (AUTO)
D.
I. 370
- 2. Turbine Speed Changer Page 67 of 75
Oconee Nuclear Station ILT4S ONSRONRCExamination Question:
68 (1 point)
Which ONE of the following is the LOWER limit on RCS activity that would require entry into AP/21 (RCS Activity)?
A.
Xe-I 33 = 0.25 pCi/gm B.
Xe-I 33 = 1.0 pCi/gm C.
DEl = 0.25 pCi/gm D.
DEl = 1.0 pCi/gm Page 68 of 75
Oconee Nuclear Station 1LT45 ONSRONRCExamination Question:
69 (1 point)
Given the following Unit I conditions:
Time = 0000 Unit shutdown in progress Reactor power = 2.5% decreasing Time = 2300 RCS Tave = 240°F decreasing
- 1) At 0000, the reactor is in MODE (1)
- 2) At 2300, the reactor is in MODE (2)
Which ONE of the following completes the statements above?
A.
1.1
- 2. 4 B.
1.1
- 2. 5 C.
1.2
- 2. 4 D.
1.2
- 2. 5 Page 69 of 75
Oconee Nuclear Station 1LT45 ONSRONRCExamination Question:
70 (1 point)
Given the following Unit I conditions:
Reactor power = 100%
Group 3 Rod 6 drops into the core Rod cannot be recovered Which ONE of the following describes action(s) required and the associated MAXIMUM completion time(s) in accordance with TS 3.1.5 (Safety Rod Position Limits)?
A.
Verify SDM within 1 hour1.157407e-5 days <br />2.777778e-4 hours <br />1.653439e-6 weeks <br />3.805e-7 months <br /> ONLY B.
Verify SDM within 30 minutes ONLY C.
Verify SDM within 1 hour1.157407e-5 days <br />2.777778e-4 hours <br />1.653439e-6 weeks <br />3.805e-7 months <br /> AND reduce reactor power to less than 60%
within 1 hour1.157407e-5 days <br />2.777778e-4 hours <br />1.653439e-6 weeks <br />3.805e-7 months <br /> D.
Verify SDM within 30 minutes AND reduce reactor power to less than 60%
within 1 hour1.157407e-5 days <br />2.777778e-4 hours <br />1.653439e-6 weeks <br />3.805e-7 months <br /> Page 70 of 75
Oconee Nuclear Station 1LT45 ONSRONRCExamination Question:
71 (1 point)
Given the following Unit 1 conditions:
Reactor power = 100%
Which ONE of the following describes a condition that would require entry into a Tech Spec ACTIONS table?
A.
UST level =7.6 feet B.
Pressurizer= 291 inches C.
ID RPS channel in Manual bypass D.
230KV Dacus Black and White lines isolated Page 71 of 75
Oconee Nuclear Station 1LT45 ONS RO NRC Examination Question:
72 (1 point)
Given the following Unit 1 conditions:
Reactor in MODE 5 Reactor Building Main Purge in operation Which ONE of the following will cause the RB Purge fan to trip?
A.
Inadvertent actuation of ES Channel 5 B.
1 RIA-45 reaches HIGH alarm setpoint C.
Suction piping pressure = 5 inches of water vacuum D.
I PR-3 (RB PURGE CONTROL) 5% open Page 72 of 75
Oconee Nuclear Station 1LT45 ONSRONRCExamination Question:
73 (1 point)
An RWP that you are preparing to work under states that the highest dose rate in a particular area (at 30 cm) is 325 mR/hr.
When you arrive at the work site, a flashing yellow light is noted in the entry path to the area.
- 1. How would an area with the dose rate specified in the RWP be designated?
- 2. What is the significance of the flashing yellow light?
A.
- 1. Radiation Area
- 2. Radiography is in progress B.
- 2. Radiography is in progress C.
- 1. Radiation Area
- 2. The area has been designated as a Locked High Radiation Area D.
- 2. The area has been designated as a Locked High Radiation Area Page 73 of 75
Oconee Nuclear Station 1LT45 ONSRONRCExamination Question:
74 (1 point)
Given the following Unit 1 conditions:
Initial conditions:
Time =0400 CTPB = 75% stable 1A HPI pump operating Transient occurs Current conditions:
Time =0405 CTPB = 76% stable Letdown Flow = 78 gpm stable HPI Flow Train A= 176 gpm decreasing slowly In accordance with OMP 1-18 (Implementation Standard During Abnormal and Emergency Events) at 0405:
- 1) Unit 1 (1) considered stable.
- 2) RCS makeup flow (2) within normal makeup capability.
Which ONE of the following completes the statements above?
A.
1.is
- 2. is B.
1.is
- 2. is NOT C.
- 1. is NOT
- 2. is D.
- 1. is NOT
- 2. is NOT Page 74 of 75
Oconee Nuclear Station 1LT45 ONSRONRCExamination Question:
75 (1 point)
- 1) The emergency facility that assumes responsibility for communications with offsite Agencies, including the NRC once it is activated, is the (1)
- 2) The lowest classification level that requires this facilitys activation is a/an (2)
Which ONE of the following completes the statements above?
A.
- 2. Alert B.
- 2. Site Area Emergency C.
- 1. Operations Support Center (OSC)
- 2. Alert D.
- 1. Operations Support Center (OSC)
- 2. Site Area Emergency Page 75 of 75
Reference Listfor: 1LT45 ONS RO NRC Examination OP/1106/OO1 End. 4.5 Printed 5/15/2014 1 :25:44 PM
Examination KEYfor: 1LT45 ONS RO NRC Examina Question Answer Number I
B 2
A 3
B 4
D 5
D 6
B 7
D 8
C 9
B 10 C
11 B
12 D
13 C
14 B
15 D
16 B
17 B
18 A
19 C
20 C
21 B
22 C
23 D
24 B
25 C
Printed5/15/2014 10:19:54AM Page 1 of3
Examination KEYfor: ILT45 ONS RO NRC Examina Question Answer Number 26 D
27 B
28 A
29 D
30 B
31 B
32 B
33 D
34 B
35 A
36 A
37 B
38 D
39 D
40 C
41 C
42 C
43 B
44 D
45 D
46 A
47 C
48 B
49 D
50 B
Printed 5/15/2014 10:19:54AM Page 2 of3
Examination KEYfor: 1LT45 ONS RO NRC Examina Question Answer Number 51 A
52 A
53 D
54 D
55 B
56 A
57 D
58 A
59 A
60 D
61 D
62 D
63 A
64 D
65 A
66 B
67 C
68 C
69 C
70 A
71 B
72 B
73 D
74 C
75 A
Printed5/15/2014 10:19:54AM Page 3 of3