.0, UNITED STATES 4
0 NUCLEAR REGULATORY COMMISSION REGION II 101 MARIETTA ST., N.W., SUITE 3100 ATLANTA, GEORGIA 30303 OCT 2 9 1979 In Reply Refer To:
RII:JPO 50-261 Carolina Power and Light Company Attn:
J. A. Jones, Senior Executive Vice President and Chief Operating Officer 411 Fayetteville Street Raleigh, North Carolina 27602 Gentlemen:
The enclosed Bulletin No. 79-17, Revision 1 is forwarded to you for action. A written response is required.
If you desire additional information regarding this matter, please contact this office.
Sincerely, James P. O'Reilly Director
Enclosure:
IE Bulletin No. 79-17, Revision 1 w/encls.
7911150 1339
Carolina Power and Light Company
-2 cc w/encl:
R. B. Starkey, Jr., Plant Manager Post Office Box 790 Hartsville, South Carolina 29550
UNITED STATES SSINS No.:
6820 NUCLEAR REGULATORY COMMISSION Accession No.:
OFFICE OF INSPECTION AND ENFORCEMENT 7908220137 WASHINGTON, D.C. 20555 J
October 29, 1979 IE Bulletin No. 79-17 Revision 1 PIPE CRACKS IN STAGNANT BORATED WATER SYSTEMS AT PWR PLANTS Description of Circumstances:
IE Bulletin No. 79-17, issued July 26, 1979, provided information on the cracking R1 experienced to date in safety-related stainless steel piping systems at PWR RI plants. Certain actions were required of all PWR facilities with an operating R1 license within a specified 90-day time frame.
R1 After several discussions with licensee owner group representatives and inspection RI agencies, it has been determined that the requirements of Item 2, particularly R1 the ultrasonic examination, may be impractical because of unavailability of RI qualified personnel in certain cases to complete the inspections within the time R1 specified by the Bulletin. To alleviate this situation and allow licensees the R1 resources of improved ultrasonic inspection capabilities, a time extension and R1 clarifications to the bulletin have been made. These are referenced to the R1 affected items of the original bulletin.
R1 During the period of November 1974 to February 1977 a number of cracking incidents have been experienced in safety-related stainless steel piping systems and por tions of systems which contain oxygenated, stagnant or essentially stagnant bor ated water. Metallurgical investigations revealed these cracks occurred in the weld heat affected zone of 8-inch to 10-inch type 304 material (schedule 10 and 40), initiating on the piping I.D. surface and propagating in either an inter granular or transgranular mode typical of Stress Corrosion Cracking. Analysis indicated the probable corrodents to be chloride and oxygen contamination in the affected systems. Plants affected up to this time were Arkansas Nuclear Unit 1, R. E. Ginna, H. B. Robinson Unit 2, Crystal River Unit 3, San Onofre Unit 1, and Surry Units 1 and 2. The NRC issued Circular No. 76-06 (copy enclosed) in view of the apparent generic nature of the problem.
During the refueling outage of Three Mile Island Unit 1 which began in February of this year, visual inspections disclosed five (5) through-wall cracks at welds in the spent fuel cooling system piping and one (1) at a weld in the decay heat removal system. These cracks were found as a result of local boric acid buildup and later confirmed by liquid penetrant tests. This initial identification of cracking was reported to the NRC in a Licensee Event Report (LER) dated May 16, 1979. A preliminary metallurgical analysis was performed by the licensee on a section of cracked and leaking weld joint from the spent fuel cooling system.
R1 -
Identifies those additions or revision to IE Bulletin No. 79-17
IE Bulletin No. 79-17 October 29, 1979 Revision 1 Page 2 of 5 The conclusion of this analysis was that cracking was due to Intergranular Stress Corrosion Cracking (IGSCC) originating on the pipe I.D. The cracking was localized to the heat affected zone where the type 304 stainless steel is sensitized (precipitated carbides) during welding. In addition to the main through-wall crack, incipient cracks were observed at several locations in the weld heat affected zone including the weld root fusion area where a miniscule lack of fusion had occurred. The stresses responsible for cracking are believed to be primarily residual welding stresses in as much as the calculated applied stresses were found to be less than code design limits. There is no conclusive evidence at this time to identify those aggressive chemical species which promoted this IGSCC attack. Further analytical efforts in this area and on other system welds are being pursued.
Based on the above analysis and visual leaks, the licensee initiated a broad based ultrasonic examination of potentially affected systems utilizing special techniques. The systems examined included the spent fuel, decay heat removal, makeup and purification, and reactor building spray systems which contain stagnant or intermittently stagnant, oxygenated boric acid environments. These systems range from 2 1/2-inch (HPCI) to 24-inch (borated water storage tank suction), are type 304 stainless steel, schedule 160 to schedule 40 thickness respectively. Results of these examinations were reported to the NRC on June 30, 1979 as an update to the May 16, 1979 LER. The ultrasonic inspection as of July 10, 1979 has identified 206 welds out of 946 inspected having UT indications characteristic of cracking randomly distributed throughout the aforementioned sizes (24"-14"-12"-10"-8"-2" etc.) of the above systems.
It is important to note that six of the crack indications were reportedly found in 2 1/2-inch diameter RI pipe of the high pressure injection lines inside containment. These lines are attached to -the main coolant pipe and are nonisolable from the main coolant system except for check valves.
All of the six crack indications were found in two R1 high pressure injection lines containing stagnated borated water. No crack R1 indications were found in high pressure injection lines which were utilized for RI makeup operations.
Recent data reported from Three Mile Island Unit 1 indicates that the extent RI of IGSCC experienced in stainless steel piping at that facility may be more R1 limited than originally stated above.
Of the 1902 total welds originally RI inspected 350 contained U.T. indications which required further evaluation.
R1 These 350 welds have been reinspected with a second U.T. procedure which pur-RI portedly provides better discrimination between actual cracks and geometrical RI reflectors. Hence, the licensee now estimates that approximately 38 of the RI
.-350 welds contain IGSCC and the remaining welds, including those in high pressure R1 injection and decay heat lines, contain only geometrical reflectors.
Further R1 metallurgical analysis of these welds is required to verify the adequacy of the R1 U.T. procedures and to determine the nature of the cracking.
R1
IE Bulletin No. 79-17 October 29, 1979 Revision 1 Page 3 of 5 For All Pressurized Water Reactor Facilities with an Operating License:
- 1.
Conduct a review of safety related stainless steel piping systems within 30 days of the date of this Bulletin (July 26, 1979) to identify systems R1 and portions of systems which contain stagnant oxygenated borated water.
These systems typically include ECCS, decay/residual heat removal, spent fuel pool cooling, containment spray and borated water storage tank (BWST RWST) piping.
For this review, the term "stagnant, oxygenated borated water systems" refers R1 to those systems serving as engineered safeguards having no normal operating R1 functions and contain essentially air saturated borated water where dynamic R1 flow conditions do not exist on a continuous basis. However, these systems R1 must be maintained ready for actuation during normal power operations. Where R1 your definition for stagnant differed from the one given above please supple-R1 ment your previous response within 30 days of this Bulletin revision.
R1 (a) Provide the extent and dates of the hydrotests, visual and volumetric examinations performed per 10 CFR 50.55a.(g) (Re: IE Circular No. 76-06 enclosed) of identified systems.
Include a description of the non destructive examination procedures, procedure qualifications and accep tance criteria, the sampling plan, results of the examinations and any related corrective actions taken.
(b) Provide a description of water chemistry controls, summary of chemistry data, any design changes and/or actions taken, such as periodic flushing or recirculation procedures to maintain required water chemistry with respect to pH, B, Cl-, F-, 02*
(c) Describe the preservice NDE performed on the weld joints of identified systems. The description is to include the applicable ASME Code sec tions and supplements (addenda) that were followed, and the acceptance criterion.
(d) Facilities having previously experienced cracking in identified systems, Item 1, are requested to identify (list) the new materials utilized in repair or replacement on a system-by-system basis.
If a report of this information and that requested above has been previously submitted to the NRC, please reference the specific report(s) in response to this Bulletin.
- 2.
All operating PWR facilities shall complete the following inspection on the RI stagnant piping systems identified in Item 1 at the earliest practical date R1 but not later than twelve months from the date of this bulletin revision.
RI Facilities which have been inspected in accordance with the original Bul-RI letin, Sections 2(a) and 2(b) satisfy the requirements of this Revision.
R1
IE Bulletin No. 79-17 October 29, 1979 Revision 1 Page 4 of 5 (a) Until the examination required by 2(b) is completed a visual examination Ri shall be made of all normally accessible welds of the engineered safety R1 systems at least monthly to verify continued systems integrity. Sim-R1 ilarly, the normally inaccessible welds, shall be visually examined R1 during each cold shutdown.
R1 The relevant provisions of Article IWA 2000 of ASME Code Section XI R1 and Article 9 of Section V are considered appropriate and an acceptable R1 basis for this examination. For insulated piping, the examination may RI be conducted without the removal of insulation. During the examination RI particular attention shall be given to both insulated and noninsulated R1 piping for evidence of leakage and/or boric acid residues which may RI have accumulated during the service period preceding the examination.
RI Where evidence of leakage and/or boric acid residues are detected at R1 locations, other than those normally expected, (such as valve stems, R1 pump seals, etc.) the piping shall be cleaned (including insulation R1 removal) to the extent necessary to permit further evaluation of the R1 piping condition. In cases where piping conditions observed are not R1 sufficiently definitive, additional inspections (i.e., surface and/or Ri volumetric) shall be conducted in accordance with Item 2.(b).
RI (b) An ultrasonic examination shall be performed on a representative sample R1 of circumferential welds in normally accessible portions of systems R1 identified by 1 above.
It is intended that the sample number of welds R1 selected for examination include all pipe diameters within the 2 1/2-R1 inch to 24-inch range with no less than a 10 percent sampling being RI taken. The approach to selection of the sample shall be based on the RI following criteria:
RI (1) Pipe Material Chemistry - As a first consideration, those welds R1 in austenitic stainless steel piping (Types 304 and 316 ss)
R1 having 0.05 to 0.08 wt. %4 carbon content based on available R1 material certification reports.
R1 (2) Pipe Size and Thickness - An unbiased mixture of pipe diameters R1 and actual wall thickness distributed among both horizontal and RI vertical piping runs shall be included in the sample.
R1 (3) System Importance - The sample welds shall focus the examination R1 primarily on those systems required to function in the emergency RI core cooling mode and secondly, on the containment spray system.
R1 The U.T. examination sample may be focused on noninsulated piping R1 runs. The evaluation shall cover the weld root fusion zone and a R1 minimum of 1/2 inch on.the pipe I.D. (counterbore area) on each side R1 of the weld. The procedure(s) for this examination shall be essentially R1
- Normally accessible refers to those areas of the plant which can be entered R1 during reactor operation.
R1
IE Bulletin No..79-17 October 29, 1979 Revision 1 Page 5 of 5 in accordance with ASME Code Section XI, Appendix III and Supplements RI of the 1975 Winter Addenda, except all signal responses shall be eval-R1 uated as to the nature of the reflectors. Other alternative examination Ri methods, combination of methods, or newly developed techniques may be R1 used provided the procedure(s) have a proven capability of detecting R1 stress corrosion cracking in austenitic stainless steel piping.
R1 For welds of systems included in the sample having pipe wall thickness R1 of 0.250 inches and below, visual and liquid penetrant surface examina-R1 tion may be used in lieu of ultrasonic examination.
R1 (c) If cracking is identified during Item 2(a) and 2(b) examinations, all R1 welds in the affected system, shall be subject to examination and repair R1 considerations.
In addition, the sample welds to be examined on the R1 remaining normally accessible noninsulated piping shall be increased to R1 25 percent using the criteria outlined in paragraph 2(b).
In the event RI that cracking is identified in other systems at this sampling level, RI all accessible and inaccessible welds of the systems identified in R1 item 1 shall be subject to examination.
R1
- 3.
Identification of cracking in one unit of a multi-unit facility which causes safety-related systems to be inoperable shall require immediate examination of accessible portions of other similar units which have not been inspected under the ISI provisions of 10 CFR 50.55a(g) unless justification for con tinued operation is provided.
- 4.
Any cracking identified shall be reported to the Director of the apppropriate NRC Regional Office within 24 hours2.777778e-4 days <br />0.00667 hours <br />3.968254e-5 weeks <br />9.132e-6 months <br /> of identification followed by a 14 day written report.
- 5.
Provide a written report to the Director of the appropriate NRC Regional R1 Office within 30 days of the date of this bulletin revision addressing the R1 results of your review if required by Item 1. Provide a schedule of your R1 inspection plans in response to Item 2(b) in those cases in which the R1 inspections have not been completed.
R1
- 6.
Provide a written report to the Director of the appropriate NRC Regional RI Office within 30 days of the date of completion of the examinations required R1 by Items 2(a), 2(b), or 2(c) describing the inspection results and any cor-R1 rective actions taken.
R1
- 7.
Copies of the reports required by Items above shall also be provided to the Director, Division of Operating Reactors, Office of Inspection and Enforce ment, Washington, D.C. 20555.
Approved by GAO, B180225 (R0072), clearance expires 7/31/80. Approval was given under a blanket clearance specifically for identified generic problems.
Enclosures:
- 1.
IE Circular No. 76-06
- 2.
List of IE Bulletins Issued in the Last Six Months
November 26, 1976 IE Circular No. 76-06 STRESS CORROSION CRACKS IN STAGNANT, LOW PRESSURE STAINLESS PIPING CONTAINING BORIC ACID SOLUTION AT PWR's DESCRIPTION OF CIRCUMSTANCES:
During the period November 7, 1974 to November 1, 1975, several incidents of through-wall cracking have occurred in the 10-inch, schedule 1.0 type 304 stainless steel piping of the Reactor Building Spray and Decay Heat Removal Systems at Arkansas Nuclear Plant No. 1.
On October 7, 1976, Virginia Electric and Power also reported through wall cracking in the 10-inch schedule 40 type 304 stainless discharge piping of the "A" recirculation spray heat exchanger at Surry Unit No. 2. A recent inspection of Unit 1 Containment Recirculation Spray Piping revealed cracking similar to Unit 2.
On October 8, 1976, another incident of similar cracking in 8-inch schedule 10 type 304 stainless piping of the Safety Injection Pump Suction Line at the Ginna facility was reported by the licensee.
Information received on the metallurgical analysis conducted to date indicates that the failures were the result of intergranular stress corrosion cracking that initiated on the inside of the piping. A commonality of factors observed associated with the corrosion mechanism were:
- 1.
The cracks were adjacent to and propagated along weld zones of the thin-walled low pressure piping, not part of the reactor coolant system.
- 2.
Cracking occurred in piping containing relatively stagnant boric acid solution not required for normal operating conditions.
- 3.
Analysis of surface products at this time indicate a chloride ion interaction with oxide formation in the relatively stagnant boric acid solution as the probable corrodant, with the state of stress probably due to welding and/or fabrication.
The source of the chloride ion is not definitely known. However, at ANO-1 the chlorides and sulfide level observed in the surface tarnish film near welds is believed to have been introduced into the piping during testing of the sodium thiosulfate discharge valves, or valve leakage. Similarly, at Ginna the chlorides and potential oxygen
IE Circular No. 76-06 November 26, 1976 availability were assumed to have been present since original construction of the borated water storage tank which is vented to atmosphere. Corrosion attack at Surry is attributed to in-leakage of chlorides through recirculation spray heat exchange tubing, allowing buildup of contaminated water in an otherwise normally dry spray piping.
ACTION TO BE TAKEN BY LICENSEE:
- 1.
Provide a description of your program for assuring continued integrity of those safety-related piping systems which are not frequently flushed, or which contain nonflowing liquids. This program should include consideration of hydrostatic testing in accordance with ASME Code Section XI rules (1974 Edition) for all active systems required for safety injection and containment spray, including their recirculation modes, from source of water supply up to the second isolation valve of the primary system.
Similar tests should be considered for other safety-related piping systems.
- 2.
Your program should also consider volumetric examination of a representative number of circumferential pipe welds by non destructive examination techniques.
Such examinations should be performed generally in accordance with Appendix I of Section XI of the ASME Code, except that the examined area should cover a distance of approximately six (6) times the pipe wall thickness (but not less than 2 inches and need not exceed 8 inches) on each side of the weld. Supplementary examination techniques, such as radiography, should be used where necessary for evaluation or confirmation of ultrasonic indications resulting from such examination.
- 3.
A report describing your program and schedule for these inspec tions should be submitted within 30 days after receipt of this Circular.
- 4.
The NRC Regional Office should be informed within 24 hours2.777778e-4 days <br />0.00667 hours <br />3.968254e-5 weeks <br />9.132e-6 months <br />, of any adverse findings resulting during nondestructive evaluation of the accessible piping welds identified above.
- 5.
A summary report of the examinations and evaluation of results should be submitted within 60 days from the date of completion of proposed testing and examinations.
IE Circular No. 76-06 November 26, 1976 This summary report should also include a brief description of plant conditions, operating procedures or other activities which provide assurance that the effluent chemistry will maintain low levels of potential corrodants in such relatively stagnant regions within the piping.
Your responses should be submitted to the Director of this office, with a copy to the NRC Office of Inspection and Enforcement, Division of Reactor Inspection Programs, Washington, D.C. 20555.
Approval of NRC requirements for reports concerning possible generic problems has been obtained under 44 U.S.C. 3152 from the U.S. General Accounting Office.
(GAO Approval B-180255 (R0062), expires 7/31/77.)
IE Bulletin No. 79-17, Revision 1 Enclosure October 29, 1979 Page 1 of 3 LISTING OF IE BULLETINS ISSUED IN LAST SIX MONTHS Bulletin No.
Subject Date Issued Issued To 79-24 Frozen Lines 9/27/79 All Power Reactor Facilities with an
-OL or a CP 79-23 Potential Failure of Emergency 9/12/79 All Power Reactor Diesel Generator Field Exciter Facilities with an Transformer OL or a CP 79-22 Possible Leakage of Tubes of 9/5/79 Each Licensee who Tritium Gas Used in Timepieces Receives Tubes of for Luminosity Tritium Gas in Time pieces for Luminosity 79-21 Temperature Effects on Level 8/13/79 All PWR's with an Measurements Operating License 79-20 Packaging Low-Level Radioactive 8/10/79 All Materials Licensees Waste for Transport and Burial who did not receive Bulletin No. 79-19 79-19 Packaging Low-Level Radioactive 8/10/79 All Power and Research Waste for Transport and Burial Reactors with OLs, Fuel Facilities except uranium mills, and certain materials licensees 79-18 Audibility Problems Encountered 8/7/79 All OLs for Action on Evacuation of Personnel from All CPs for Information High-Noise Areas 79-17 Pipe Cracks in Stagnant Borated 10/29/79 All PWRs with (Rev. 1)
Water Systems at PWR Plants Operating License 79-17 Pipe Cracks in Stagnant Borated 7/26/79 All PWRs with Water Systems at PWR Plants Operating License 79-16 Vital Area Access Controls 7/26/79 All Holders of and applicants for Power Reactor Operating Licenses who Antici page loading fuel prior to 1981 79-15 Deep Draft Pump Deficiencies 7/18/79 All Power Reactor (Supp. 1)
IE Bulletin No. 79-13, Revision 2 Enclosure October 17, 1979 Page 2 of 3 LISTING OF IE BULLETINS ISSUED IN LAST SIX MONTHS Bulletin No.
Subject Date Issued Issued To 79-15 Deep Draft Pump Deficiencies 7/11/79 All Power Reactor Licensees with a CP and/or OL 79-14 Seismic Analyses for As-Built 7/27/79 All Power Reactor (Correction)
Safety-Related Piping System Facilities with an OL or a CP 79-14 Seismic Analyses for As-Built 9/7/79 All Power Reactor (Supp. 2)
Safety-Related Piping System Facilities with an OL or a CP 79-14 Seismic Analyses for As-Built 7/18/79 All Power Reactor (Rev. 1)
Safety-Related Piping System Facilities with an OL or a CP 79-14 Seismic Analyses for As-Built 7/2/79 All Power Reactor Safety-Related Piping System Facilities with an OL or a CP 79-13 Cracking in Feedwater System 10/17/79 All PWR's with an (Rev. 2)
Piping Operating License 79-13 Cracking in Feedwater System 8/30/79 All PWR's with an (Rev. 1)
Piping Operating License 79-13 Cracking in Feedwater System 6/25/79 All PWR's with an Piping OL for action. All BWRs with a CP for information 79-12 Short Period Scrams at BWR 5/31/79 All GE BWR Facilities Facilities with an OL 79-11 Faulty Overcurrent Trip Device 5/22/79 All Power Reactor in Circuit Breakers for Engin-Facilities with an eered Safety Systems OL or a CP 79-10 Requalification Training 5/11/79 All Power Reactor Program Statistics Facilities with an OL 79-06C Nuclear Incident at Three Mile 7/26/79 To all PWR Power Island - Supplement Reactor Facilities with an OL
IE Bulletin No. 79-13, Revision 2 Enclosure October 17, 1979 Page 3 of 3 LISTING OF IE BULLETINS ISSUED IN LAST SIX MONTHS Bulletin
. No.
Subject Date Issued Issued To 79-05C Nuclear Incident at Three 7/26/79 To all PWR Power Mile Island - Supplement Reactor Facilities with an OL 79-02 Pipe Support Base Plate Designs 8/20/79 All Power Reactor (Rev. 1)
Using Concrete Expansion Anchor Facilities with an (Supp. 1)
Bolts OL or a CP 79-02 Pipe Support Base Plate Designs 6/21/79 All Power Reactor (Rev. 1)
Using Concrete Expansion Anchor Facilities with an Bolts OL or a CP 79-01A Environmental Qualification of 6/6/79 All Power Reactor Class 1E Equipment (Deficien-Facilities with an cies in the Environmental OL or a CP Qualification of ASCO Sole noid Valves)