ML14122A344

From kanterella
Jump to navigation Jump to search
2013 Annual Radioactive Effluent Release Report
ML14122A344
Person / Time
Site: Browns Ferry  
(DPR-033, DPR-052, DPR-068)
Issue date: 04/30/2014
From: Polson K
Tennessee Valley Authority
To:
Document Control Desk, Office of Nuclear Reactor Regulation
References
Download: ML14122A344 (180)


Text

Tennessee Valley Authority, 1101 Market Street, Chattanooga, Tennessee 37402 April 30, 2014 10 CFR 50.4 10 CFR 50.36a ATTN: Document Control Desk U.S. Nuclear Regulatory Commission Washington, D.C. 20555-0001 Browns Ferry Nuclear Plant, Units 1, 2, and 3 Facility Operating License Nos. DPR-33, DPR-52, and DPR-68 NRC Docket Nos. 50-259, 50-260, and 50-296

Subject:

2013 Annual Radioactive Effluent Release Report In accordance with the Browns Ferry Nuclear Plant (BFN), Units 1, 2, and 3, Technical Specification Section 5.6.3, the Tennessee Valley Authority is submitting the BFN Annual Radioactive Effluent Release Report for the period January through December 2013. This document is in conformance with Title 10 of the Code of Federal Regulations (10 CFR) 50.36a and 10 CFR Part 50, Appendix I Section IV.B.1. to the Enclosure documents deviations which have occurred from Offsite Dose Calculation Manual (ODCM) controls and surveillance requirements. Attachment 2 to the Enclosure provides information on radiological effluent instrumentation inoperable for greater than 30 days. There were no revisions to the ODCM during 2013.

There are no new regulatory commitments contained in this letter. Should you have any questions concerning this submittal, please contact J. L. Paul at (256) 729-2636.

Enclosure:

Browns Ferry Nuclear Plant, Units 1, 2, and 3, 2013 Annual Radioactive Effluent Release Report

ENCLOSURE Browns Ferry Nuclear Plant Units 1, 2, and 3 2013 Annual Radioactive Effluent Release Report See Enclosed

BROWNS FERRY NUCLEAR PLANT UNITS 1, 2, AND 3 2013 ANNUAL RADIOACTIVE EFFLUENT RELEASE REPORT TABLE OF CONTENTS Section Title Paae Number Supplemental Information E E-10 Gaseous Effluents E E-17 Liquid Effluents E E-21 Solid Waste E E-29 Radiological Impact E E-46 Meteorological Data E E-176 Attachment I - Deviations from ODCM Controls and Surveillance Requirements E-177 - Inoperable Radiological Effluent Instrumentation Report E-178 Tables Page Number Table 1A, Gaseous Effluents - Summation of All Releases E-1 1 Table 1 B, Gaseous Effluents - Elevated Releases E E-13 Table 1C, Gaseous Effluents - Ground Level Releases E E-15 Table 1D, Gaseous Effluents - Mixed Mode Releases E E-17 Table 2A, Liquid Effluents - Summation of All Releases E-18 Table 2B, Liquid Effluents E E-21 Table 3, Solid Waste and Irradiated Fuel Shipments E E-29 Table 4, Radiological Impact, Doses from Airborne Effluents E E-40 Table 5, Radiological Impact, Doses from Liquid Effluents E

E-44 Table 5A, Radiological Impact, Total Doses from 1-131 E-45 Water Ingestion Pathway Table 6, Radiological Impact, Total Dose from Fuel Cycle E-46 Table 7A, Meteorological Data, Joint Frequency Distribution E E-54 Ground Level Releases, First Quarter E-1

BROWNS FERRY NUCLEAR PLANT UNITS 1, 2, AND 3 2013 ANNUAL RADIOACTIVE EFFLUENT RELEASE REPORT TABLE OF CONTENTS Tables Table 78, Meteorological Data, Joint Frequency Distribution Ground Level Releases, Second Quarter Table 7C, Meteorological Data, Joint Frequency Distribution Ground Level Releases, Third Quarter Table 7D, Meteorological Data, Joint Frequency Distribution Ground Level Releases, Fourth Quarter Table 8A, Meteorological Data, Joint Frequency Distribution Split Level Releases, First Quarter Table 88, Meteorological Data, Joint Frequency Distribution Split Level Releases, Second Quarter Table 8C, Meteorological Data, Joint Frequency Distribution Split Level Releases, Third Quarter Table 8D. Meteorological Data, Joint Frequency Distribution Split Level Releases, Fourth Quarter Table 9A, Meteorological Data, Joint Frequency Distribution Elevated Releases, First Quarter Table 98, Meteorological Data, Joint Frequency Distribution Elevated Level Releases, Second Quarter Table 9C, Meteorological Data, Joint Frequency Distribution Elevated Level Releases, Third Quarter Table 9D, Meteorological Data, Joint Frequency Distribution Elevated Level Releases, Fourth Quarter Page Number E E-64 E E-72 E E-80 E E-95 E-96 -- E-112 E-113 -

E-127 E-128 -

E-142 E-143 -

E-150 E-151 -

E-160 E-161 -

E-168 E-169 -

E-176 E-2

BROWNS FERRY NUCLEAR PLANT UNITS 1, 2, AND 3 2013 ANNUAL RADIOACTIVE EFFLUENT RELEASE REPORT SUPPLEMENTAL INFORMATION

1. Re-qulatory and BFN ODCM Limits
a. Fission and Activation Gases in Gaseous Effluent:

The release of fission and activation gases is regulated by the dose limits of Title 10 of the Code of Federal Regulations (10 CFR) 50 Appendix I and Browns Ferry Nuclear Plant (BFN) Offsite Dose Calculation Manual (ODCM). The air dose to areas at and beyond the site boundary due to noble gases released in gaseous effluents per unit shall be limited during any calendar quarter to < 5 millirad (mrad) for gamma radiation and < 10 mrad for beta radiation; and during any calendar year to :5 10 mrad for gamma radiation and < 20 mrad for beta radiation.

b. lodines and Particulates with Half-Lives Greater than Eight Days in Gaseous Effluents:

The release of iodines and particulates in gaseous effluent is regulated by the dose limits of 10 CFR 50 Appendix I and the BFN ODCM. The dose to a member of the public from radioiodines, radioactive materials in particulate form, and radionuclides other than noble gases with half-lives greater than eight days in gaseous effluent released per unit to areas at and beyond the site boundary shall be limited to any organ during any calendar quarter to < 7.5 millirem (mrem), and during any calendar year to < 15 mrem.

c. Liquid Effluents:

The release of radioactive liquid effluents is regulated by the dose limits of 10 CFR 50 Appendix I and the BFN ODCM. The doses or dose commitment to a member of the public from radioactive materials in liquid effluents released from each unit to unrestricted areas shall be limited during any calendar quarter to :5 1.5 mrem to the total body and <5 mrem to any organ and during any calendar year to :5 3 mrem to the total body and : 10 mrem to any organ.

2. Limitation on Dose Rate
a. Fission and Activation Gases in Gaseous Effluent:
1. The instantaneous release rate of fission and activation gases is based on the dose rate limits of 10 CFR 20.1301 and the BFN ODCM. The dose rate at any time to areas at and beyond the site boundary due to noble gases released in gaseous effluents from the site shall be limited to :5 500 mrem per year to the total body and < 3000 mrem per year to the skin.
2. The BFN ODCM Section 7.2 determines the maximum noble gas release rate.

E-3

BROWNS FERRY NUCLEAR PLANT UNITS 1, 2, AND 3 2013 ANNUAL RADIOACTIVE EFFLUENT RELEASE REPORT SUPPLEMENTAL INFORMATION

2. Limitation on Dose Rate (Continued)
b. lodines and Particulates with Half-Lives Greater than Eight Days in Gaseous Effluents:
1. The instantaneous release rate of particulates and iodines is regulated by the dose rate limits of the BFN ODCM. The dose rate at any time to areas at and beyond the site boundary, due to 1-131, 1-133, H-3, and particulates with half-lives greater than eight days in gaseous effluent released from the site, shall be limited to 5 1500 mrem per year to any organ.
2. The BFN ODCM Section 7.3 determines the maximum particulate and iodine dose rates.
c. Liquid Effluents:
1. The concentration of radionuclides in liquid effluents released at any time from the site to unrestricted areas shall be limited to the concentrations specified in 10 CFR 20.1001-20.2402, Appendix B, Table 2, Column 2 for radionuclides other than dissolved or entrained noble gases
2. For dissolved or entrained noble gases, the concentration shall be limited to 2E-4 piCi per milliliter (ml) total activity.
3. Average Energy The BFN ODCM limits the dose equivalent rates due to the release of noble gases to less than or equal to 500 mrem/year to the total body and less than or equal to 3000 mrem/year to the skin. The use of dose rate is in accordance with NUREG-0133, "Preparation of Radiological Effluent Technical Specifications for Nuclear Power Plants."

Since the release rate is not used for effluent control, the average beta and gamma energies (E) for gaseous effluents discussed in Regulatory Guide 1.21, "Measuring, Evaluation, and Reporting Radioactivity in Solid Wastes and Releases of Radioactive Materials in Liquid and Gaseous Effluents from Light-Water-Cooled Nuclear Power Plants," are not applicable and not included in this report.

E-4

BROWNS FERRY NUCLEAR PLANT UNITS 1, 2, AND 3 2013 ANNUAL RADIOACTIVE EFFLUENT RELEASE REPORT SUPPLEMENTAL INFORMATION

4. Measurements and Approximations of Total Radioactivity
a. Fission and activation gases:
1. Noble gases in the building vent and stack (elevated) gaseous effluents are continuously monitored. The flow rate of the stack is continuously monitored and the building vent effluent flow rates are calculated once a shift based on the configuration of operating exhaust fans. The vent flow is calculated for each release. Gas grab samples of the stack are taken and analyzed weekly. Gas grab samples of in-service vents are taken and analyzed monthly. The specific noble gas activity concentrations and total volume of the gases are used to calculate the total Curies of noble gases released.
2. The tritium concentration is determined by the analysis of a monthly grab sample for each release point.
b. lodines and Particulates:
1. lodines and particulates are continuously sampled on impregnated charcoal filters and particulate filters, respectively. The charcoal and particulate samples are replaced at least weekly and analyzed to determine specific activity concentrations. The specific activity concentrations and vent flow rate data are used weekly to verify that release rate limits were not exceeded. The specific activity concentrations and total volume of gaseous effluent are used on a monthly basis to determine the total curies of each particulate and iodine released during the month.
2. The gross alpha concentration is determined by analysis of a monthly particulate filter composite sample, and strontium-89 and strontium-90 are determined by analysis of a quarterly particulate filter composite sample for each release point.
c. Liquid effluents:
1. The gamma ray emitting radionuclide concentrations are determined for each batch by gamma ray spectroscopy analysis of a grab sample. The allowable release rate is calculated for each batch based upon the known dilution flow.

The flow rate of the liquid effluent is continuously monitored and the total volume released in each batch is determined. The total gamma activity released in each batch is determined by multiplying the radionuclide concentrations by the total volume discharged. The total gamma activity released during the month is then determined by summing the gamma activity content of each batch discharged during the month.

E-5

BROWNS FERRY NUCLEAR PLANT UNITS 1, 2, AND 3 2013 ANNUAL RADIOACTIVE EFFLUENT RELEASE REPORT SUPPLEMENTAL INFORMATION

4. Measurements and Approximations of Total Radioactivity (Continued)
c. Liquid effluents (Continued):
2. The gross alpha and tritium concentrations are measured on a monthly composite sample. The strontium-89, strontium-90, and iron-55 are measured on a quarterly composite sample.
d. The Radioactive Gaseous and Liquid Waste Monitoring Sampling and Analysis Program is specified in ODCM Sections 1/2.2.1 and 1/2.2.2. No liquid or gaseous concentration or dose limits were exceeded.
5. Batch Releases Quarter Quarter Quarter Quarter A.

Liquid Units 1

2 3

4

1. Number of batches released Each 324**

174**

4 3

2. Total time for batches released Minutes 69172.00 30879.00 1251.00 855.00
3. Maximum time period for a batch release Minutes 2730.00 400.00 380.00 355.00
4. Average time period for a batch release Minutes 213.49 177.47 312.75 285.00
5. Minimum time period for a batch release Minutes 100.00 110.00 241.00 180.00
6. Average BFN beach flow during period of ft3/sec 100077 67684 56208 50773 release into the river stream B.

Gaseous None

    • Batch releases include the releases from tanks other than the established plant Radwaste discharge tanks. An explanation of these tanks are documented on Attachment I E-6

BROWNS FERRY NUCLEAR PLANT UNITS 1, 2, AND 3 2013 ANNUAL RADIOACTIVE EFFLUENT RELEASE REPORT SUPPLEMENTAL INFORMATION

6. Abnormal Releases
a. Liquid
1. Number of releases: 3
2. Total activity released (pCi/ml):

Destination Nuclide Quarter 1 Quarter 2 Quarter 3 Leak to H-3 6.37E-01 4.90E-01 5.61 E-01 River Quarter 4 9.24E-02

b. Gaseous
1. Number of releases: 2
2. Total activity released (pCi/ci):

Destination Nuclide Quarter 1 Air H-3 1-131 Quarter 2 6.92E-02 Quarter 3 7.89E-04 9.OOE-09 Quarter 4 E-7

BROWNS FERRY NUCLEAR PLANT UNITS 1, 2, AND 3 2013 ANNUAL RADIOACTIVE EFFLUENT RELEASE REPORT SUPPLEMENTAL INFORMATION

6. Abnormal Releases (Continued)

Summary of Abnormal/Unplanned Releases The release of radioactive material to the environment from BFN has been a small fraction of the 10 CFR 20 Appendix B and 10 CFR 50 Appendix I limits. There were no limits exceeded as specified in 10 CFR 20 Appendix B and 10 CFR 50 Appendix I.

Three abnormal liquid releases occurred in 2013.

1.

Throughout the year tritium was detected and released through the U1, U2, and U3 Station Sumps. The probable source was the Turbine Building Air Wash System from April through September and the U3 Roughing Cooler for U3 Station Sump from October to December (PER 707675 and PER 830901).

Due to the increased incidences of Tritium identified in BFN Station Sumps, PER 619986 was initiated to include Station Sumps in the ODCM as a normal permitted discharge point rather than continuing to report in the ARERR as an abnormal release.

2.

The Sedimentation Pond was sampled on April 2, 2013 with a tritium concentration of 1.36E-06 uCi/ml. The Sedimentation Pond was resampled on April 3, 2013 with a tritium concentration of < LLD. (PER 707649)

3.

The Sedimentation Pond was sampled on October 18, 2013 with a tritium concentration of 1.45E-06 uCi/ml. (PER 869822)

Two abnormal gaseous releases occurred in 2013.

1.

Unit 1 USST 1A phase A bus link panel was found missing bolts in the top corner and the buss link panel was loose. The bus duct air could be heard blowing out of it. Panel was blown out approximately 1 inch. (PER 763270)

2.

On April 1, 2013 at 1315, Auxiliary Decay Heat Removal (ADHR) sample showed a tritium concentration of 2.67E-06 uCi/ml. (PER 707641)

E-8

BROWNS FERRY NUCLEAR PLANT UNITS 1, 2, AND 3 2013 ANNUAL RADIOACTIVE EFFLUENT RELEASE REPORT SUPPLEMENTAL INFORMATION

6.

Abnormal Releases (Continued)

Ground Water Monitoring Onsite groundwater monitoring locations were sampled during the year. These locations were not part of the BFN Radiological Environmental Monitoring Program (REMP). The purpose of these shallow wells was to monitor for potential leaks from plant equipment.

Trace levels of tritium were detected in several of these monitoring locations. In the early 2000's, BFN initiated a groundwater study to identify the source of the tritium.

Results from a groundwater study completed in June 2006 suggest the source of the tritiated groundwater is associated with the Radwaste/Condensate Transfer Tunnel.

Water that may leak into the tunnel could egress via expansion joints and/or cracks through the tunnel wall. These joints and/or cracks were grouted during 2008 with several more leaks grouted in 2010. Groundwater and surface water level measurements during the study indicated the return channel and subsequently the Tennessee River will ultimately be recipient to tritiated groundwater discharge from the site. The highest concentration identified in the groundwater for the year 2013, was 5772 pCi/L (Dewat A). The estimated groundwater/channel water dilution ratio is 1:20,000 at a rate of approximately 0.5 gpm. The tritium concentrations obtained in 2013 from these non-REMP wells are listed below.

Well ID R1 (1305)

R1 (1305)

R2 (1306)

R2 (1306)

R-3 (1307)

R-3 (1307)

R-3 (1307)

R-3 (1307)

R3 (1307)

BH25(1309)

BH25(1309)

BH25(1309)

BH25(1309)

BH25(1309)

BH25(1309)

BH25 (1309)

DEWAT A(1 311)

(PER 624796 and 679394)

Date 2/20/2013 3/13/2013 6/18/2013 6/20/2013 2/20/2013 3/13/2013 5/22/2013 7/18/2013 10/10/2013 1/21/2013 2/20/2013 3/13/2013 4/12/2013 5/22/2013 7/18/2013 10/10/2013 1/21/2013 Activity in pCilL 325 241 217 219 511 563 556 390 386 579 479 356 312 347 270 310 5772 Well ID DEWAT A(1311)

DEWAT A(1311)

DEWAT A(1311)

DEWAT A(1311)

DEWAT A(1311)

DEWAT A(1 311)

DEWAT A(1311)

DEWAT E(1 312)

(PER 624796 and 679394)

DEWAT E(1 312)

DEWAT E(1 312)

DEWAT E(1 312)

DEWAT E(1 312)

DEWAT E(1 312)

DEWAT E(1 312)

DEWAT E(1312)

DSN13C-1 Date 2/21/2013 3/13/2013 4/12/2013 5/22/2013 7/18/2013 8/15/2013 10/10/2013 1/2112013 2/21/2013 3/13/2013 4/12/2013 5/22/2013 7/18/2013 8/15/2013 10/10/2013 10/10/2013 Activity in pCi/L 1023 854 1309 281 2970 717 470 2795 2950 2664 2409 2311 260 668 577 228 E-9

BROWNS FERRY NUCLEAR PLANT UNITS 1, 2, AND 3 2013 ANNUAL RADIOACTIVE EFFLUENT RELEASE REPORT SUPPLEMENTAL INFORMATION

6. Abnormal Releases (Continued)

Liquid Radwaste or Temporary Storage Tanks During the reporting period, January 1, 2013 through December 31, 2013, BFN utilized 7 temporary outside liquid radwaste (FRAC) tanks from January through May of 2013.

These tanks were used to process batch releases to the river from the excess water in the radwaste basement. All releases were permitted and documented by performance of surveillance 0-SI-4.8.A.1-1(a) in accordance with ODCM requirements (Reference PER 662887)

Changes to the Radwaste System and Changes to the Process Control Program In calendar year 2013, BFN had no permanent changes to the Radwaste System or the Process Control Program. The previous paragraph documents the Temporary Storage Tanks brought on-site due to Radwaste basement water increase from CCW leaks.

These temporary tanks were removed from service in May, 2013 when the plant Liquid Radwaste Treatment System resumed all processing operations.

Missed Compensatory Samples During the reporting period, January 1, 2013 through December 31, 2013, there were no missed compensatory samples.

E-1 0

BROWNS FERRY NUCLEAR PLANT UNITS 1, 2, AND 3 2013 ANNUAL RADIOACTIVE EFFLUENT RELEASE REPORT GASEOUS EFFLUENTS TABLE 1A Page 1 of I Gaseous Effluents - Summation of All Releases Units Quarter 1 Quarter 2 Quarter 3 Quarter 4 A. Fission and Activation Gases

1. Total Releases
2. Average Release Rate for Period
3. Percent of Applicable Limit B. lodines
1. Total Iodine-131
2. Average Release Rate for Period
3. Percent of Applicable Limit C. Particulates
1. Particulates with half-lives

> eight days

2. Average Release Rate for Period
3. Percent of Applicable Limit
4. Gross Alpha Radioactivity D. Tritium
1. Total Release
2. Average Release Rate for Period
3. Percent of Applicable Limit E. Carbon-14***
1. Total Release
2. Total as CO 2 Curies pCi/sec Curies giCi/sec Curies igCi/sec Curies Curies giCi/sec Curies Curies Error 45 36 35 1.12E-03 1.44E-04 1.08E-03 1.38E-04 1.58E-03*

1.99E-04 1.23E-03 1.55E-04 1.26E-03 9.41E-04 2.41E-02 1.74E-02 1.62E-04 4.93E+01 6.35E+00 8.25E+00 7.84E+00 1.20E-04 2.36E+01*

3.OOE+00 8.78E+00 8.34E+00 3.03E-03 1.03E+02*

1.29E+01 1.02E+01 9.66E+00 2.19E-03 1.11E+02 21 1.40E+01 9.88E+00 9.39E+00

  • - Includes Activity from Abnormal Release
    • - Not Detected.

- Estimated using EPRI methodology provided in EPRI Report 1021106.

- Applicable Limits are expressed in terms of dose. See Enclosure 1.

E-11

BROWNS FERRY NUCLEAR PLANT UNITS 1, 2, AND 3 2013 ANNUAL RADIOACTIVE EFFLUENT RELEASE REPORT GASEOUS EFFLUENTS (Continuous Mode Only)

TABLE 1B Page 1 of 2 Gaseous Effluents - Elevated Releases CURIES Fission Gases Kr-85m Kr-85 Kr-87 Kr-88 Xe-133 Xe-135m Xe-135 Xe-138 Others (N-13)

Total for Period

2.

lodines 1-131 1-135 1-133 Total for Period

  • - Not Detected.

Quarter 1 Quarter 2 Quarter 3 C)uarter 4 3.82E-04 1.33E-03 1.71 E-03

'k*

2.80E-04 7.54E-04 1.03E-03 3.32E-04 7.36E-04 1.07E-03 1.75E-04 3.96E-04 5.71 E-04 E-12

BROWNS FERRY NUCLEAR PLANT UNITS 1, 2, AND 3 2013 ANNUAL RADIOACTIVE EFFLUENT RELEASE REPORT GASEOUS EFFLUENTS (Continuous Mode Only)

TABLE 1B (Continued)

Page 2 of 2 Gaseous Effluents - Elevated Releases CURIES Quarter 1 Quarter 2 Quarter 3 Q

3.

Particulates*

Sr-89 1.87E-04 1.77E-04 1.11 E-04 Sr-90 Sr-91 2.72E-03 3.80E-03 2.07E-03 Cs-134 Cs-137 Ba-140 2.83E-04 3.24E-04 1.78E-04 La-140 1.76E-04 2.17E-04 1.14E-04 Te-132 Zn-69m 3.38E-06 5.22E-06 Others (Au-199) 7.02E-06 Rb-88 2.63E-02 Rb-89 1.02E-01 Y-91m 1.95E-03 2.50E-03 1.27E-03 Cs-1 38 3.28E-02 8.45E-03 Ce-144 3.62E-06 Ba-1 39 2.16E-01 2.73E-01 1.52E-01 Total for Period*

2.22E-01 4.42E-01 1.64E-01

4.

Tritium 1.16E+00 1.01E+00 6.97E+00 9.69E-05 1.35E-03

1. 51 E-04 9.82E-05 9.46E-04 1.09E-01 1.12E-01 3.09E+00
5. Carbon-14***

7.84E+00 8.34E+00 9.66E+00 9.39E+00

  • - Includes all nuclides, even those with less than an eight day half-life.
    • - Not Detected.

- Estimated using EPRI methodology provided in EPRI Report 1021106.

E-1 3

BROWNS FERRY NUCLEAR PLANT UNITS 1, 2, AND 3 2013 ANNUAL RADIOACTIVE EFFLUENT RELEASE REPORT GASEOUS EFFLUENTS (Continuous Mode Only)

TABLE 1C Page 1 of 2 Gaseous Effluents - Ground Level Releases Quarter 1 Quarter 2 Quarter 3 CURIES

1.

Fission Gases Kr-85m Kr-85 Kr-87 Kr-88 Xe-133 Xe-135m Xe-135 Xe-138 Ar-41 Other (specify)

Total for Period

2.

lodines Quarter 4 1-131 1-132 1-133 3.48E-04 1.48E-03 3.60E-04 1.57E-03 1.93E-03 4.38E-04"*

1.60E-03 2.04E-03 4.06E-04 1.70E-03 2.11E-03 Total for Period 1.83E

  • - Not Detected.
    • - Activity from Abnormal Release.

E-03 E-14

BROWNS FERRY NUCLEAR PLANT UNITS 1, 2, AND 3 2013 ANNUAL RADIOACTIVE EFFLUENT RELEASE REPORT GASEOUS EFFLUENTS (Continuous Mode Only)

TABLE IC (Continued)

Page 2 of 2 Gaseous Effluents - Ground Level Releases CURIES Quarter I Quarter 2 Quarter 3 Quarter 4

3. Particulates*

Co-60 3.60E-06 3.62E-07 Sr-89 5.90E-06 7.42E-08 2.52E-05 Sr-90 Cs-134 Cs-137 Ba-140 1.20E-05 3.35E-06 5.21E-06 3.93E-05 La-140 2.71 E-05 Sr-91 5.80E-05 1.64E-04 Sr-92 7.87E-05 Y-91m 3.85E-04 2.69E-04 1.88E-04 6.17E-04 Cs-138 6.33E-02 4.36E-03 4.27E-03 3.36E-03 Ba-139 1.79E-02 1.69E-02 6.57E-03 6.92E-03 Total for Period*

8.16E-02 2.16E-02 1.1 OE-02 1.11 E-02

4.

Tritium 8.05E+00 4.33E+00***

1.14E+01***

1.75E+01

  • - Include all nuclides even those with less than an eight day half-life.
    • - Not Detected.

- Includes Activity from Abnormal Release.

E-15

BROWNS FERRY NUCLEAR PLANT UNITS 1, 2, AND 3 2013 ANNUAL RADIOACTIVE EFFLUENT RELEASE REPORT GASEOUS EFFLUENTS (Continuous Mode Only)

TABLE ID Page 1 of 2 Gaseous Effluents - Mixed Mode Releases Quarter 1 Quarter 2 Quarter 3 CURIES 1

Fission Gases Kr-85m Kr-85 Kr-87 Kr-88 Xe-133 Xe-135m Xe-135 Xe-138 Other (specify)

Total for Period

2.

lodines 1-131 1-132 1-133 Total for Period 3.6E0 1.6E0 2.5E0 4.4E0 2.0E0 2.4E0

    • A 8.08E-04 5.83E-05 4.50E-03 5.37E-03 Quarter 4 "A*
    • k
    • k 6.50E-04 3.56E-04 3.49E-03 4.49E-03
  • - The Reactor Building and Radwaste Building are treated
    • - Not Detected.

as split-level releases.

E-16

BROWNS FERRY NUCLEAR PLANT UNITS 1, 2, AND 3 2013 ANNUAL RADIOACTIVE EFFLUENT RELEASE REPORT GASEOUS EFFLUENTS (Continuous Mode Only)

TABLE 1D (Continued)

Page 2 of 2 Gaseous Effluents - Mixed Mode Releases CURIES Quarter 1 Quarter 2 Quarter 3 Quarter 4

3.

Particulates**

Sr-89 Ce-141 Cs-137 Ba-140 La-140 Na-24 Mn-54 Mn-56 Co-57 Co-58 Co-60 Zn-65 Y-91m Sr-91 Sr-92 Cs-138 Ba-139 Y-92 Total for Period**

4.

Tritium 3.82E-05 1.59E-06 9.60E-05 1.90E-04 1.02E-04 1.45E-05 8.91 E-07 8.95E-06 4.06E-04 9.30E-06 1.73E-03 1.71 E-03 3.91 E-04 5.56E-04 6.66E-02 7.19E-02 4.01 E+01 3.60E-05 7.03E-05 1.24E-04 8.90E-05 1.69E-05 5.71 E-04 1.79E-04 1.78E-03 7.27E-04 9.81 E-03 1.16E-01 1.30E-01 5.07E-05 1.69E-04 2.31 E-04 1.01E-04 2.92E-05 5.34E-04 2.52E-03 1.02E-03 4.66E-03 1.14E-01 1.23E-01 8.53E-05 7.03E-06 3.59E-04 2.07E-04 8.75E-06 2.66E-06 1.78E-04 3.93E-03 5.37E-03 2.45E-04 1.37E-02 1.45E-01 1.05E-03 1.71E-01 8.73E+01 1.82E+01 8.42E+01

  • - The Reactor Building and Radwaste Building are treated as split-level releases.
    • - Includes all nuclides, even those with less than an eight day half-life.

- Not Detected.

E-17

BROWNS FERRY NUCLEAR PLANT UNITS 1, 2, AND 3 2013 ANNUAL RADIOACTIVE EFFLUENT RELEASE REPORT LIQUID EFFLUENTS (Batch Mode Only)

TABLE 2A Page 1 of 1 Liquid Effluents - Summation of All Releases A. Fission and Activation Products (Does not include tritium, gases, alpha)

1.

Total Release

2.

Average Diluted Concentration Released During the Period

3.

Percent of Applicable Limit B. Tritium

1.

Total Releases

2.

Average Diluted Concentration Released During Period Units Quarter 1 Curies 6.93E-01 Quarter 2 Quarter 3 Quarter 4 Error %

5.47E-01 2.36E-02 1.06E-04 9

7.80E-09 8.31E-09 8.16E-11 ACi/ml 4.54E-09 Curies 4.47E+01** 3.61E+O1** 4.29E+O0** 2.82E+OO**

6 jaCi/ml 2.93E-07 5.15E-07 1.51 E-06 2.18E-06 C

3.

Percent of Applicable Limit Dissolved and Entrained Noble Gases

1.

Total Releases Curies 1.56E-03 7.56E-04 1.02E-11 1.07E-11 2.21E-05 8

1.71E-11

2.

Average Diluted Concentration jiCi/ml Released During Period

3.

Percent of Applicable Limit D Gross Alpha Radioactivity

1.

Total Releases Curies

  • k
  • r 48
2.

Average Diluted Concentration gCi/ml Released During Period E. Volume of Liquid Waste to Discharge Canal (Prior to dilution)

F. Volume of Dilution Water for Period Liters 2.82E+07 1.51E+07 4.55E+05 2.88E+05 3

Liters 1.52E+11 7.01E+10 2.84E+09 1.29E+09 10 Gigagal 2.30E+02 2.31 E+02 2.66E+02 2.37E+02 G Total CCW

  • - Not Detected.
    • - Includes activity from abnormal releases. Dilution flow was not determined for the abnormal releases.

- The applicable limit is expressed in terms of dose. See Radiological Impact Report.

E-18

BROWNS FERRY NUCLEAR PLANT UNITS 1, 2, AND 3 2013 ANNUAL RADIOACTIVE EFFLUENT RELEASE REPORT LIQUID EFFLUENTS TABLE 2B Page 1 of 3 Liquid Effluents Isotope in Curies Quarter 1 Quarter 2 Quarter 3 Quarter 4 (Required by Regulatory (REG) Guide 1.21)

1.

Ba-140 2.89E-02 2.29E-03

2.

Ce-141 8.75E-06

3.

Co-58 1.76E-02 1.67E-02 2.OOE-04

4.

Co-60 1.83E-01 2.48E-01 1.21 E-02 3.50E-05

5.

Cr-51 1.06E-03 3.89E-04

6.

Cs-134 6.87E-03 3.55E-03 2.74E-04 1.47E-06

7.

Cs-137 2.23E-01 1.35E-01 8.46E-03 6.42E-05

8.

Fe-59 1.44E-03

9.

1-131 6.96E-04 6.78E-04

10.

La-140 1.19E-02 4.50E-04

11.

Mn-54 4.14E-02 7.22E-02 7.81E-04 2.83E-06

12.

Mo-99 4.OOE-04 2.07E-03

13.

Nb-95 2.78E-06 2.88E-05

14.

Sr-89 5.06E-02 2.17E-02 1.59E-04

15.

Sr-90 2.29E-03 1.16E-03 4.82E-06

16.

Tc-99m 3.59E-04 1.22E-03

17.

Xe-133 6.97E-04 5.55E-04 1.24E-05

18.

Xe-135 8.38E-04 1.60E-04 9.76E-06

19.

Zn-65 2.88E-02 5.65E-03 3.24E-04

20.

Zr-95

  • - Not Detected.

E-19

BROWNS FERRY NUCLEAR PLANT UNITS 1, 2, AND 3 2013 ANNUAL RADIOACTIVE EFFLUENT RELEASE REPORT LIQUID EFFLUENTS TABLE 2B (Continued)

Page 2 of 3 Liquid Effluents Isotope Others In Curies (Not Required by REG Guide 1.21)

Quarter 1 Quarter 2 Quarter 3 Quarter 4

1.

F-18 4.15E-02 2.OOE-02 8.95E-05 2.17E-06

2.

Fe-55 5.65E-03 3.06E-03 2.35E-04

3.

Mn-56 7.89E-04

4.

Zn-69m 1.20E-03 4.26E-06

5.

Nb-97 4.29E-05 4.77E-12

6.

Ag-11Om 4.54E-03 4.1OE-04 1.36E-04

7.

Sb-122 6.08E-05 1.75E-05

8.

1-133 6.25E-04 1.60E-03 9

As-76 3.OOE-04 5.69E-05

10.

Na-24 2.87E-02 1.04E-02 8.54E-04

11.

Y-91m 3.49E-03 5.85E-04

12.

Ba-139 1.80E-04

13.

Br-84 4.03E-05

14.

Co-57 5.37E-06

15.

Cs-1 38 8.71 E-06

16.

1-134 6.03E-05

17.

La-142 6.42E-06 18 Ni-65 1.46E-05 9.15E-06

19.

Rb-89 5.70E-05 20 Sb-124 9.40E-04 2.19E-04

21.

Sr-91 5.49E-03 1.55E-04

22.

Sr-92 2.99E-04 8.73E-05 1.13E-05 23 Tc-101 2.69E-05

24.

Te-132 3.48E-06 E-20

BROWNS FERRY NUCLEAR PLANT UNITS 1, 2, AND 3 2013 ANNUAL RADIOACTIVE EFFLUENT RELEASE REPORT LIQUID EFFLUENTS TABLE 2B (Continued)

Page 3 of 3 Liquid Effluents Isotope Others In Curies (Not Required by REG Guide 1.21)

Quarter I Quarter 2 Quarter 3 Quarter 4

25.

Zr-97 1.07E-05

26.

Ar-41 4.43E-06 2.87E-06

27.

Kr-87 7.83E-06

28.

Xe-1 35m 7.56E-06 3.75E-05

29.

Be-7 4.06E-05

  • - Not Detected.

E-21

BROWNS FERRY NUCLEAR PLANT UNITS 1, 2, AND 3 2013 ANNUAL RADIOACTIVE EFFLUENT RELEASE REPORT Solid Waste TABLE 3 Page 1 of 8 Solid Waste and Irradiated Fuel Shipments A. Solid Waste Shipped Offsite for Burial or Disposal (not Irradiated Fuel)

1. Type of Waste
a.

Spent resins, filters, sludges, evaporator bottoms, etc.

Unit m

3 Ci Jan - Jun 2013 1.23E+02 6.35E+02 July-Dec 2013 4.OOE+01 3.90E+01 Error %

+/- 25%

+/- 25%

b.

Dry Active Waste, Compressible Waste Contaminated Equipment, etc.

c.

Irradiated Components, Control Rods

& LPRMs with fission chambers

d.

Other - Combined Packages HIC RWCU 2002 m3 Ci m

3 Ci m

3 Ci 1.44E+03 2.46E+00 1.49E+00 8.04E+04 1.1OE+02 8.50E+00 6.15E+02 1.96E-01 2.08E-01 4.78E+01 1.18E+02 2.69E+00

+/- 25%

+/- 25%

+/- 25%

+/- 25%

+/- 25%

+/- 25%

E-22

BROWNS FERRY NUCLEAR PLANT UNITS 1, 2, AND 3 2013 ANNUAL RADIOACTIVE EFFLUENT RELEASE REPORT Solid Waste TABLE 3 (Continued)

Page 2 of 8 Solid Waste and Irradiated Fuel Shipment

2. Estimate of Major Nuclide Composition
a. Spent resins, filters, sludges, evaporator bottoms, etc.

Nuclide 1) 2)

3) 4)

5) 6)

7) 8)

9) 10) 11) 12) 13) 14) 15) 16) 17) 18) 19) 20) 21) 22) 23) 24) 25)

H-3 C-14 Cr-51 Mn-54 Fe-55 Fe-59 Co-57 Co-58 Co-60 Ni-63 Cu-64 Zn-65 Zn-69m Sr-89 Sr-90 Zr-95 Tc-99 Ag-110m SB-124 SB-125 1-131 1-133 CS-134 CS-136 CS-1 37 Percentage 5.82E-02 6,23E-02 1.04E-01 2.21 E+00 1.93E+01 1.68E-01 9.54E-05 4.39E-01 3.49E+01 1.43E+00 1.27E-06

.18E+00 4.44E-12 1.69E-04 8.19E-02 2.75E-04 9.41 E-02 3.16E-01 5.33E-04 4.75E-04 4.14E-02 5.77E-08 2.66E+00 3.03E-44 3.68E+01 Curies 3.92E-01 4.20E-01 6.99E-01 1.49E+01 1.30E+02 1.13E+00 6.43E-04 2.96E+00 2.35E+02 9.66E+00 8.54E-06 7.96E+00 2.99E-1 1 1.14E-03 5.52E-01 1.85E-03 6.34E-01 2.13E+00 3.59E-03 3.20E-03 2.79E-01 3.89E-07 1.79E+01 2.04E-43 2.48E+02 E-23

BROWNS FERRY NUCLEAR PLANT UNITS 1, 2, AND 3 2013 ANNUAL RADIOACTIVE EFFLUENT RELEASE REPORT Solid Waste TABLE 3 (Continued)

Page 3 of 8 Solid Waste and Irradiated Fuel Shipment

2. Estimate of Major Nuclide Composition (Continued)
a. Spent resins, filters, sludges, evaporator bottoms, etc. (Continued)

Nuclide Percentage Curies

26)

BA-140 4.56E-02 3.07E-01

27)

LA-140 2.94E-04 1.98E-03

28)

CE-141 1.63E-02 1.10E-01

29)

CE-144 8.29E-02 5.59E-01

30)

PU-238 5.79E-04 3.90E-03

31)

PU-239 3.34E-05 2.25E-04

32)

PU-240 3.34E-05 2.25E-04

33)

PU-241 4.27E-02 2.88E-01

34)

AM-241 5.34E-04 3.60E-03

35)

CM-242 4.70E-05 3.17E-04

36)

CM-243 3.77E-04 2.54E-03

37)

CM-244 3.40E-04 2.29E-03 E-24

BROWNS FERRY NUCLEAR PLANT UNITS 1, 2, AND 3 2013 ANNUAL RADIOACTIVE EFFLUENT RELEASE REPORT Solid Waste TABLE 3 (Continued)

Page 4 of 8 Solid Waste and Irradiated Fuel Shipments

2. Estimate of Major Nuclide Composition (Continued)
b.

Dry Active Waste, Compressible Waste Contaminated Equipment, etc.

Nuclide Percentage Curies

1)

H-3 2.OOE-02 5.30E-04

2)

C-14 3.20E-02 8.49E-04

3)

CR-51 7.39E-01 1.96E-02

4)

MN-54 4.97E+00 1.32E-01

5)

FE-55 2.59E+01 6.88E-01

6)

FE-59 1.20E-01 3.18E-03

7)

CO-58 6.33E-01 1.68E-02

8)

CO-60 4.07E+01 1.08E+00

9)

NI-63 1.14E+00 3.02E-02

10)

ZN-65 7.16E+00 1.90E-01

11)

SR-89 1.21E-01 3.20E-03

12)

SR-90 3.72E-02 9.86E-04

13)

ZR-95 9.87E-03 2.62E-04

14)

NB-95 2.26E-04 5.99E-06

15)

TC-99 1.61E-02 4.27E-04

16)

AG-11Om 1.70E+00 4.50E-02

17)

SN-113 0.OOE+00 0.OOE+00

18)

SB-124 2.01E-02 5.32E-04

19)

SB-125 0.OOE+00 O.OOE+00

20) 1-131 2.95E-03 7.83E-05
21)

CS-134 2.23E+00 5.91E-02

22)

CS-137 1.44E+01 3.81E-01

23)

BA-140 1.51 E-02 4.01E-04

24)

LA-140 2.97E-12 7.88E-14

25)

CE-141 2.59E-02 6.88E-04

26)

CE-144 1.49E-02 3.95E-04

27)

PU-238 6.82E-05 1.81 E-06

28)

PU-241 3.1OE-03 8.22E-05

29)

AM-241 6.14E-05 1.63E-06

30)

CM-242 1.18E-07 3.12E-09

31)

CM-243 6.03E-05 1.60E-06

32)

CM-244 6.03E-05 1.60E-06 E-25

BROWNS FERRY NUCLEAR PLANT UNITS 1, 2, AND 3 2013 ANNUAL RADIOACTIVE EFFLUENT RELEASE REPORT Solid Waste TABLE 3 (Continued)

Page 5 of 8' Solid Waste and Irradiated Fuel Shipments

2. Estimate of Major Nuclide Composition (Continued)
c. Irradiated Components, Control Rods, etc.

Nuclide Percentage Curies

1)

H-3 5.14E-03 4.13E+00

2)

C-14 1.26E-02 1.01E+01

3)

MN-54 2.62E-01 2.11E+02

4)

FE-55 3.38E+01 2.72E+04

5)

CO-60 5.86E+01 4.71 E+04

6)

NI-59 3.68E-02 2.96E+01

7)

NI-63 7.24E+00 5.82E+03

8)

NB-94 1.49E-04 1.20E-01

9)

TC-99 5.41 E-05 4.35E-02

10)

CS-137 1.24E-04 1.O0E-01

11)

CE-144 7.54E-07 6.06E-04

12)

HF-181 6.89E-03 5.54E+00

13)

TA-182 2.70E-02 2.17E+01

14)

U-235 2.51E-10 2.02E-07

15)

NP-237 6.52E-09 5.24E-06

16)

PU-238 9.39E-05 7.55E-02

17)

PU-239 7.75E-08 6.23E-05

18)

PU-240 1.12E-07 9.04E-05

19)

PU-241 1.85E-05 1.49E-02

20)

AM-241 2.OOE-07 1.61 E-04

21)

AM-243 6.65E-09 5.35E-06

22)

CM-242 6.52E-08 5.24E-05

23)

CM-243 6.14E-09 4.94E-06

24)

CM-244 1.46E-06 1.17E-03 E-26

BROWNS FERRY NUCLEAR PLANT UNITS 1, 2, AND 3 2013 ANNUAL RADIOACTIVE EFFLUENT RELEASE REPORT Solid Waste TABLE 3 (Continued)

Page 6 of 8 Solid Waste and Irradiated Fuel Shipments

2. Estimate of Major Nuclide Composition (Continued) d Other (Combined Packages)

Nuclide Percentagqe Curies

1)

H-3 9.29E-04 1.04E-04

2)

C-14 3.71E-02 4.15E-03

3)

K-40 1.45E-02 1.62E-03

4)

CR-51 1.75E-01 1.96E-02

5)

MN-54 6.41E+00 7.17E-01

6)

FE-55 4.OOE+01 4.48E+00

7)

FE-59 1.16E-01 1.30E-02

8)

CO-57 8.93E-04 1.OOE-04

9)

CO-58 7.07E-01 7.91 E-02

10)

CO-60 3.55E+01 3.97E+00

11)

NI-63 5.76E-01 6.45E-02

12)

ZN-65 4.18E+00 4.68E-01

13)

SR-89 3.55E-02 3.97E-03

14)

SR-90 3.OOE-02 3.36E-03

15)

ZR-95 2.29E-02 2.56E-03

16)

NB-95 3.12E-02 3.49E-03

17)

TC-99 1.OOE-03 1.12E-04

18)

AG-110M 1.78E+00 1.99E-01

19)

SN-113 2.46E-04 2.75E-05

20)

SB-124 2.93E-02 3.28E-03

21)

SB-125 4.45E-03 4.98E-04

22) 1-131 2.42E-02 2.71 E-03
23)

CS-1 34 2.64E+00 2.96E-01

24)

CS-137 7.53E+00 8.43E-01

25)

BA-140 1.70E-02 1.90E-03

26)

LA-140 7.26E-04 8.13E-05

27)

CE-141 3.39E-02 3.79E-03

28)

CE-144 1.03E-01 1.15E-02 E-27

BROWNS FERRY NUCLEAR PLANT UNITS 1, 2, AND 3 2013 ANNUAL RADIOACTIVE EFFLUENT RELEASE REPORT Solid Waste TABLE 3 (Continued)

Page 7 of 8 Solid Waste and Irradiated Fuel Shipments

2. Estimate of Major Nuclide Composition (Continued) d Other (Combined Packages)

Nuclide Percentage Curies

29)

PU-238 5.16E-05 5.78E-06

30)

PU-239 1.90E-05 2.13E-06

31)

PU-240 1.85E-05 2.07E-06

32)

PU-241 1.16E-02 1.30E-03

33)

AM-241 1.27E-04 1.42E-05

34)

CM-242 8.67E-05 9.71E-06

35)

CM-243 1.11E-04 1.24E-05

36)

CM-244 1.08E-04 1.21 E-05 E-28

BROWNS FERRY NUCLEAR PLANT UNITS 1, 2, AND 3 2013 ANNUAL RADIOACTIVE EFFLUENT RELEASE REPORT Solid Waste TABLE 3 (Continued)

Page 8 of 8 Solid Waste and Irradiated Fuel Shipments

3. Solid Waste Disposition Number of Shipments 21 Mode of Transportation HIC/Cask, Sole Use Truck 14 71 14 HIC/Cask, Sole Use Truck 53-Truck 18 - HIC/Cask Sole Use Truck 14 - Sole/Non Sole Use Truck Destination Barnwell Processing Facility Barnwell, SC Waste Control Specialist Andrews, TX Duratek Oak Ridge, TN Toxco, Inc.

Oak Ridge, TN B. Irradiated Fuel Shipments Number of Shipments 8

Mode of Transportation HIC/Cask Sole Use Destination Waste Control Specialist Andrews, TX E-29

BROWNS FERRY NUCLEAR PLANT UNITS 1, 2, AND 3 2013 ANNUAL RADIOACTIVE EFFLUENT RELEASE REPORT RADIOLOGICAL IMPACT

1. Introduction Potential doses to the "maximum exposed individual" and the population around Browns Ferry Nuclear Plant (BFN) are calculated for each quarter as required in Section 5.2 of the Offsite Dose Calculation Manual (ODCM).

The methodology used to estimate dose for determining plant releases for the reporting period is specified in Sections 6 and 7 of the ODCM. Dispersion of radioactive effluents in the environment is estimated using meteorological data and river flow measured during the period. In this report, the doses resulting from releases are described and compared to limits established for BFN.

2. Dose Limits The ODCM specifies limits for the release of radioactive effluents, as well as limits for doses to the general public from the release of radioactive effluents. These limits are set well below the Technical Specification limits which govern the concentrations of radioactivity and doses permissible in unrestricted areas. This ensures that radioactive effluent releases are As Low As Reasonably Achievable.

The air dose limits in areas at and beyond the Site Boundary due to noble gases released in gaseous effluents per unit are:

< 5 mrad per quarter and

< 10 mrad per year for gamma radiation.

- and -

< 10 mrad per quarter and

< 20 mrad per year for beta radiation.

The dose limits to a member of the public in an unrestricted area from radioiodines, radioactive materials in particulate form, and radionuclides other than noble gases with half-lives > 8 days released in gaseous effluents for each unit are:

5 7.5 mrem per quarter and

< 15 mrem per year to any organ.

The dose or dose commitment to a member of the public from radioactive material in liquid effluents released to unrestricted areas are:

< 1.5 mrem per quarter and

< 3 mrem per year to the total body,

- and -

< 5 mrem per quarter and

< 10 mrem per year to any organ.

The limit for the total effective dose equivalent to an individual member of the public inside the site boundary is:

100 mrem per year.

E-30

BROWNS FERRY NUCLEAR PLANT UNITS 1, 2, AND 3 2013 ANNUAL RADIOACTIVE EFFLUENT RELEASE REPORT RADIOLOGICAL IMPACT

2. Dose Limits (Continued)

The Environmental Protection Agency limits for total dose to any member of the public in the vicinity of a nuclear power plant, established in the Environmental Dose Standard of 40 CFR 190, are:

< 25 mrem per year to the whole body,

< 75 mrem per year to the thyroid,

- and -

< 25 mrem per year to any other organ.

3. Dose Calculations Estimated doses to members of the public are determined using computer models (the Gaseous Effluent Licensing Code, and the Quarterly Water Dose Assessment Code (QWATA)).

These models are based on guidance provided by the Nuclear Regulatory Commission (NRC) for determining the potential dose to individuals and populations living in the vicinity of the plant.

The area around the plant is analyzed to determine the pathways through which the public may receive a dose. The doses calculated are a representation of the dose to a "maximum exposed individual."

Some of the factors used in these calculations (such as ingestion rates) are maximum values to ensure conservative reporting data.

The values chosen will tend to overestimate the dose. The expected dose to actual individuals is lower. The calculated doses are presented in Tables 4, 5, and 6.

4. Doses From Airborne Effluents For airborne effluents, members of the public can be exposed to radiation from several sources:

direct radiation from the radioactivity in the air, direct radiation from radioactivity deposited on the ground, inhalation of airborne radioactivity, ingestion of vegetation which contains radioactivity deposited from the atmosphere, and ingestion of milk and beef which contains radioactivity deposited from the atmosphere onto vegetation and subsequently consumed by animals.

a. Airborne Release Points There are four monitored release points from BFN: the turbine building, the radwaste building, the reactor building, and the stack.

Releases from the turbine building are considered ground-level releases. The ground-level Joint Frequency Distribution (JFD) is derived from wind speeds and directions measured 10.5 meters above the ground and from the vertical temperature difference between 10.03 and 45.30 meters, and are presented for each quarter in the 2013 Meteorological Data Tables 7A, 7B, 7C, and 7D.

E-31

BROWNS FERRY NUCLEAR PLANT UNITS 1, 2, AND 3 2013 ANNUAL RADIOACTIVE EFFLUENT RELEASE REPORT RADIOLOGICAL IMPACT

4. Doses From Airborne Effluents (Continued)
a. Airborne Release Points (Continued)

Releases from the radwaste and reactor buildings are considered split-level releases.

Portions of the release are treated as ground-level while other portions are considered elevated depending on the ratio of the vertical exit velocity to the horizontal wind speed.

The split-level dispersion approach is implemented using a model that requires two complete quarterly JFDs for each effluent vent, one for the ground-level releases and one for the elevated releases. The ground-level portion of the split-level JFD is based on wind speeds and directions measured 10.5 meters above ground-level and from the vertical temperature difference between 10.03 and 45.30 meters. The elevated portion of the split-level JFD is based on wind speeds and direction measurements at the 45.74 meter level and the vertical temperature difference between 10.03 and 89.59 meters. Both of these JFDs are given for each quarter in the 2013 Meteorological Data Tables 8A, 8B, 8C, and 8D.

Releases from the stack are considered to be elevated releases. The JFDs for elevated releases are based on wind directions and wind speeds measured at 90.29 meters and the vertical temperature difference between 10.03 and 89.59 meters, and are given for each quarter in the 2013 Meteorological Data Tables 9A, 9B, 9C, 9D.

b. Meteorological Data Meteorological variables at BFN are measured continuously. Measurements collected include wind speed and wind direction at heights of 10.5, 45.74, and 90.29 meters above the ground, and temperature at heights of 10.03, 45.30, and 89.59 meters above the ground. Quarterly JFDs are calculated for each release point using the appropriate levels of meteorological data. A quarterly JFD gives the percentage of the time that the wind is blowing out of a particular upwind compass sector in a particular range of wind speeds for a given stability class A through G. The wind speeds are divided into nine wind speed ranges. Calms are distributed by direction in proportion to the distribution of noncalm wind directions less than 1.6 m/s (3.5 mph). Stability classes are determined from the vertical temperature difference between two measurement levels.

The generally open terrain around BFN does not cause any significant effects on the transport and dispersion of gaseous effluents from the plant. Within 30 kilometers of BFN, the terrain is mostly gently rolling hills (30-60 meters). Between 30 and 80 kilometers, the hills become larger to the north and south and mountainous to the east and northeast. The Tennessee River/Wheeler Lake may have a minor effect on transport and dispersion in the immediate vicinity of BFN during periods of winds with a southerly component, overcast skies, and relatively high wind speeds. Also, the lower layer (10-45 meters) stability class tends to be more stable. However, during this infrequent condition, dose estimates will be conservative.

E-32

BROWNS FERRY NUCLEAR PLANT UNITS 1, 2, AND 3 2013 ANNUAL RADIOACTIVE EFFLUENT RELEASE REPORT RADIOLOGICAL IMPACT

4. Doses From Airborne Effluents (Continued)
c. External Exposure Dose Dose calculated for maximum external air dose (gamma-air and beta-air) are made for points at and beyond the unrestricted area boundary as described in the BFN ODCM. The highest of these doses is then selected.
d. Submersion Dose External doses to the skin and total body, due to submersion in a cloud of noble gases, are calculated for the nearest residence in each sector. The residence with the highest dose is then selected from all sectors.
e. Oraan Dose Dose to an organ due to releases of airborne effluents are estimated for the inhalation, ground contamination, and ingestion pathways. The ingestion pathway is further divided into three possible contributing pathways: ingestion of cow/goat milk, ingestion of beef, and ingestion of vegetables. Doses from applicable pathways are calculated for each receptor location identified in the most recent land use survey. To determine the maximum organ dose, the doses from the pathways are summed for each receptor. However, for the ingestion dose, only those pathways that exist for each receptor are considered in the sum, e.g., milk ingestion doses are included only for locations where milk was consumed without commercial preparation and vegetable ingestion is included only for those locations where a garden was identified. To conservatively account for beef ingestion, a beef ingestion dose equal to that for the highest unrestricted area boundary location is added to each identified receptor. For ground contamination, the dose added to the organ dose being calculated is the total body dose calculated for that location, i.e., it is assumed that the dose to an individual organ is equal to the total body dose.

The maximum organ dose, thyroid dose, and total body dose from airborne effluents are presented in Table 4.

5. Doses From Liquid Effluents For liquid effluents, the public can be exposed to radiation from three sources: the ingestion of water from the Tennessee River, the ingestion of fish caught in the Tennessee River, and direct exposure from radioactive material deposited on the river shoreline sediment (recreation).

The concentration of radionuclides in the Tennessee River is calculated by a computer model which uses measured hydraulic data downstream of BFN. Parameters used to determine the doses are based on guidance given by the NRC for maximum ingestion rates, exposure times, etc.

E-33

BROWNS FERRY NUCLEAR PLANT UNITS 1, 2, AND 3 2013 ANNUAL RADIOACTIVE EFFLUENT RELEASE REPORT RADIOLOGICAL IMPACT

5. Doses From Liquid Effluents (Continued)

Wherever possible, parameters used in the dose calculation are site specific. The models that are used to estimate doses, as well as the parameters input to the models, are described in detail in the BFN ODCM.

a. Liquid Release Points and River Data Radionuclide concentrations in the Tennessee River are calculated assuming that releases in liquid effluents are continuous. When necessary, liquid releases from BFN, located at Tennessee River Mile 294, are made through diffusers which extend into the Tennessee River. It is assumed that releases to the river through these diffusers will initially be entrained in one-fifth of the water which flows past the plant. The QWATA code makes the assumption that this mixing condition holds true until the water is completely mixed at the first downstream dam (Wheeler Dam), at Tennessee River Mile 283.

Doses are calculated for locations within a 50 mile radius downstream of the plant site. The maximum potential recreation dose is calculated for a location immediately downstream from the plant's release point. The maximum exposed individual dose from ingestion of fish is assumed to be that calculated for the consumption of fish caught anywhere between the plant and the first downstream dam. The maximum exposed individual dose from drinking water is assumed to be that calculated at the nearest downstream public water supply

[West Morgan - East Lawrence (WMEL)]. This could be interpreted as indicating that the maximum exposed individual, as assumed for liquid releases from BFN, is an individual who obtains all of his drinking water at WMEL, consumes fish caught from the Tennessee River between BFN and Wheeler Dam, and spends 500 hours0.00579 days <br />0.139 hours <br />8.267196e-4 weeks <br />1.9025e-4 months <br /> per year on the shoreline just downstream of the plant's release point. Doses calculated for the maximum exposed individual due to liquid effluents for each quarter in the period are presented in Table 5 along with the average river flows past the plant site for the periods.

6. Population Doses Population doses due to airborne effluents are calculated for an estimated 778,266 people living within a 50-mile radius of the plant site. Doses from external pathways and inhalation are based on the 50-mile human population distribution. Ingestion population doses are calculated assuming that each individual consumed milk, vegetables, and meat produced within the sector in which the individual resides.

Population doses due to liquid effluents are calculated for the entire downstream Tennessee River population. Water ingestion population doses are calculated using actual population figures for downstream public water supplies. Fish ingestion population doses are calculated assuming that all sport fish caught in the Tennessee River are consumed by the Tennessee River population. Recreation population doses are calculated using historical recreational data on the number of shoreline visits at downstream locations.

Population doses calculated for airborne and liquid effluents are presented in Tables 4 and 5.

E-34

BROWNS FERRY NUCLEAR PLANT UNITS 1, 2, AND 3 2013 ANNUAL RADIOACTIVE EFFLUENT RELEASE REPORT RADIOLOGICAL IMPACT

7. Offsite Direct Radiation Dose External gamma radiation levels were measured by environmental dosimeters deployed around BFN as part of the offsite Radiological Environmental Monitoring Program (REMP).

The quarterly gamma radiation levels determined from these dosimeters during this reporting period averaged approximately 18 mrem/quarter at onsite (at or near the site boundary) stations and approximately 15 mrem/quarter at offsite stations or approximately 2.5 mrem/quarter higher onsite than at offsite stations. This difference is consistent with levels measured for pre-operation and construction phases of the Tennessee Valley Authority nuclear plants where the average radiation levels onsite were generally 2-6 mrem/quarter higher than the levels offsite. This may be attributable to natural variations in environmental radiation levels, earth moving activities onsite, the mass of concrete employed in the construction of the plants, or other undetermined influences.

Fluctuations in natural background dose rates and in dosimeter readings tend to mask any small increments which may be due to plant operations. Thus, there was no identifiable increase in dose rate levels attributable to direct radiation from plant equipment and/or gaseous effluents.

8. Dose To A Member Of The Public Inside The Site Boundary Pursuant to ODCM Section 7.7.5, a review was performed to determine the highest dose to a member of the public in the site boundary. The dose to a member of the public consists of the sum of dose commitments from effluent releases as well as any direct radiation dose.

The gaseous effluent dose commitment is negligible compared to the direct radiation dose.

The direct radiation dose was determined from area environmental dosimeters located onsite. It consisted of gamma dose from the plume, ground contamination, and from equipment sources (i.e., tanks, turbine shine, radioactive material storage areas, etc.). The critical location was determined to be a Thermoluminescent Dosimeter near the Livewell Center (Training Center). The direct radiation dose accounting for background and occupancy was 0.00 mrem during 2013.

The total annual dose commitment to a member of the public for 2013 is 0.00 mrem. It can be concluded that the dose limit for a member of the public at the site boundary as specified in 10 CFR 20.1301 was not exceeded.

E-35

BROWNS FERRY NUCLEAR PLANT UNITS 1, 2, AND 3 2013 ANNUAL RADIOACTIVE EFFLUENT RELEASE REPORT RADIOLOGICAL IMPACT

9. Total Dose To determine compliance with 40 CFR 190, annual total dose contributions to the maximum exposed individual from BFN radioactive effluents and all other nearby uranium fuel cycle sources are considered.

The annual dose to any organ other than the thyroid for the maximum exposed individual is conservatively calculated by summing the following doses: the total body air submersion dose for each quarter, the critical organ dose (for any organ other than the thyroid) from airborne effluents for each quarter from ground contamination, inhalation and ingestion, the total body dose from liquid effluents for each quarter, the maximum organ dose (for any organ other than the thyroid) from liquid effluents for each quarter, and any identifiable increase in direct radiation dose levels as measured by the REMP. This dose is compared to the 40 CFR 190 limit for total body or any organ dose (other than the thyroid) to determine compliance.

The annual thyroid dose to the maximum exposed individual is conservatively estimated by summing the following doses: the total body air submersion dose for each quarter, the thyroid dose from airborne effluents for each quarter, the total body dose from liquid effluents for each quarter, the thyroid dose from liquid effluents for each quarter, and any identifiable increase in direct radiation dose levels as measured by the REMP. This dose is compared to the 40 CFR 190 limit for thyroid dose to determine compliance.

Total dose from the fuel cycle is presented in Table 6.

E-36

BROWNS FERRY NUCLEAR PLANT UNITS 1, 2, AND 3 2013 ANNUAL RADIOACTIVE EFFLUENT RELEASE REPORT RADIOLOGICAL IMPACT TABLE 4 Page 1 of 4 Doses from Airborne Effluents First Quarter Individual Doses Pathway Dose Quarterly Percent of Location Limit Limit External Gamma Air 1.41E-10 mrad 5 mrad

<I %

NNW/1650 meters Beta Air 4.3 1E-10 mrad 10 mrad

< 1%

NNW/1650 meters Submersion Total Body 1.32E-03 mrem NA NA ESE/1750 meters Skin 1.55E-03 mrem NA NA ESE/1750 meters Organ Doses Child/Bone 1.62E-02 mrem 7.5 mrem

< I%

N/2540 meters Child/Thyroid 1.18E-02 mrem 7.5 mrem

< 1%

N/2540 meters Child/Total Body 9.42E-03 mrem 7.5 mrem

< I%

N/2540 meters Population Doses Total Body Dose 1.24E-01 man-rem Maximum Organ Dose (organ) 4.97E-01 man-rem (Bone)

Population doses can be compared to the natural background dose for the entire 50-mile population of about 70,044 man-rem/year (based on 90 mrem/yr for natural background).

E-37

BROWNS FERRY NUCLEAR PLANT UNITS 1, 2, AND 3 2013 ANNUAL RADIOACTIVE EFFLUENT RELEASE REPORT RADIOLOGICAL IMPACT TABLE 4 (Continued)

Page 2 of 4 Doses from Airborne Effluents Second Quarter*

Individual Doses Pathway Dose Quarterly Percent of Location Limit Limit External Gamma Air 3.09E-10 mrad 5 mrad

< 1%

NNW/1650 meters Beta Air 9.45E-10 mrad 10 mrad

< 1 %

NNW/1650 meters Submersion Total Body 4.97E-04 mrem NA NA NNW/1650 meters Skin 5.83E-04 mrem NA NA NNW/1650 meters Organ Doses Child/Bone 1.89E-02 mrem 7.5 mrem

< 1%

NNW/2800 meters Child/Thyroid 1.02E-02 mrem 7.5 mrem

< 1%

N/2540 meters Child/Total 6.73E-03 mrem 7.5 mrem

< I%

N/2540 meters Body I

I I

I

_I Population Doses Total Body Dose 1.23E-01 man-rem Maximum Organ Dose (organ) 5.41E-01 man-rem (bone)

Population doses can be compared to the natural background dose for the entire 50-mile population of about 70,044 man-rem/year (based on 90 mrem/yr for natural background).

  • Includes dose from abnormal releases.

E-38

BROWNS FERRY NUCLEAR PLANT UNITS 1, 2, AND 3 2013 ANNUAL RADIOACTIVE EFFLUENT RELEASE REPORT RADIOLOGICAL IMPACT TABLE 4 (Continued)

Page 3 of 4 Doses from Airborne Effluents Third Quarter*

Individual Doses Pathway Dose Quarterly Percent of Location Limit Limit External Gamma Air 1.89-10 mrad 5 mrad

< I%

S/2250 meters Beta Air 5.77E-10 mrad 10 mrad

< 1%

S/2250 meters Submersion Total Body 1.65E-03 mrem NA NA NNW/1650 meters Skin 1.94E-03 mrem NA NA NNW/1650 meters Organ Doses Child/Bone 3.72E-02 mrem 7.5 mrem

< 1%

NNW/2800 meters Child/Thyroid 1.90E-02 mrem 7.5 mrem 2.5 %

NNW/2680 meters Child/Total 1.61 E-02 mrem 7.5 mrem 2.1 %

NNW/2680 meters Body I

I I

I

_I Population Doses Total Body Dose 2.07E-01 man-rem Maximum Organ Dose (organ) 7.81E-01 man-rem (bone)

Population doses can be compared to the natural background dose.for the entire 50-mile population of about 70,044 man-rem/year (based on 90 mrem/yr for natural background).

  • Includes dose from abnormal releases.

E-39

BROWNS FERRY NUCLEAR PLANT UNITS 1, 2, AND 3 2013 ANNUAL RADIOACTIVE EFFLUENT RELEASE REPORT RADIOLOGICAL IMPACT TABLE 4 (Continued)

Page 4 of 4 Doses from Airborne Effluents Fourth Quarter Individual Doses Pathway Dose Quarterly Percent of Location Limit Limit External Gamma Air 2.81E-10 mrad 5 mrad

< 1%

S/2250 meters Beta Air 8.59E-10 mrad 10 mrad

< I%

S/2250 meters Submersion Total Body 3.27E-04 mrem NA NA NNW/1639 meters Skin 3.84E-04 mrem NA NA NNW/1639 meters Organ Doses Child/ Bone 2.96E-02 mrem 7.5 mrem

< 1%

NNW/2680 meters Child/Thyroid 2.18E-02 mrem 7.5 mrem

< I%

NNW/2680 meters Child /Total 1.86E-02 mrem 7.5 mrem NNW/2680 meters Body

_1 1

1 1

Population Doses Total Body Dose 1.84E-01 man-rem Maximum Organ Dose (organ) 6.07E-01 man-rem (bone)

Population doses can be compared to the natural background dose for the entire 50-mile population of about 70,044 man-rem/year (based on 90 mrem/yr for natural background).

E-40

BROWNS FERRY NUCLEAR PLANT UNITS 1, 2, AND 3 2013 ANNUAL RADIOACTIVE EFFLUENT RELEASE REPORT RADIOLOGICAL IMPACT Table 5 Page 1 of 4 Doses from Liquid Effluents First Quarter*

Individual Doses (mrem)

Age Group Organ Dose Pathway Dose Quarterly Percent of Limit Limit Adult Total Body Fish Ingestion 2.6E-02 Recreation 4.7E-03 Water Ingestion 7.4E-04 Total 3.1E-02 1.5 mrem 2 %

Child Bone Fish Ingestion 3.9E-02 Recreation 4.7E-03 Water Ingestion 3.6E-03 Total 4.7E-02 5 mrem

< 1 %

Child Thyroid Fish Ingestion 3.9E-05 Recreation 4.7E-03 Water Ingestion 2.5E-04 Total 5.OE-03 5 mrem

< 1 %

Average Riverflow past BFN (cubic feet per second): 100077 Population Doses Total Body Dose 2.2E-01 man-rem Maximum Organ Dose (organ) 3.2E-01 man-rem (bone)

Population doses can be compared to the natural background dose for the entire 50-mile population of about 70,044 man-rem/year (based on 90 mrem/yr for natural background).

  • Includes dose from abnormal releases.

E-41

BROWNS FERRY NUCLEAR PLANT UNITS 1, 2, AND 3 2013 ANNUAL RADIOACTIVE EFFLUENT RELEASE REPORT RADIOLOGICAL IMPACT Table 5 (Continued)

Page 2 of 4 Doses from Liquid Effluents Second Quarter*

Individual Doses (mrem)

Age Group Organ Dose Pathway Dose Quarterly Percent of Limit Limit Adult Total Body Fish Ingestion 2.3E-02 Recreation 7.6E-03 Water Ingestion 7.0E-04 Total 3.1E-02 1.5 mrem 2 %

Child Bone Fish Ingestion 3.4E-02 Recreation 7.6E-03 Water Ingestion 2.8E-03 Total 4.4E-02 5 mrem

< 1 %

Infant Thyroid Fish Ingestion O.OOE+00 Recreation 7.6E-03 Water Ingestion 3.8E-04 Total 8.OE-03 5 mrem

< 1 %

Average Riverflow past BFN (cubic feet per second): 67684 Population Doses Total Body Dose 3.8E-01 man-rem Maximum Organ Dose (organ) 4.7E-01 man-rem (bone)

Population doses can be compared to the natural background dose for the entire 50-mile population of about 70,044 man-rem/year (based on 90 mrem/yr for natural background).

  • Includes dose from abnormal releases.

E-42

BROWNS FERRY NUCLEAR PLANT UNITS 1, 2, AND 3 2013 ANNUAL RADIOACTIVE EFFLUENT RELEASE REPORT RADIOLOGICAL IMPACT Table 5 (Continued)

Page 3 of 4 Doses from Liquid Effluents Third Quarter*

Individual Doses (mrem)

Age Group Organ Dose Pathway Dose Quarterly Percent of Limit Limit Adult Total Body Fish Ingestion 1.7E-03 Recreation 4.7E-04 Water Ingestion 5.6E-05 Total 2.2E-03 1.5 mrem

< 1 %

Teen Liver Fish Ingestion 2.7E-03 Recreation 4.7E-04 Water Ingestion 6.1E-05 Total 3.2E-03 5 mrem

<I %

Child Thyroid Fish Ingestion 3.7E-07 Recreation 4.7E-04 Water Ingestion 2.9E-05 Total 5.OE-04 5 mrem

< 1 %

Average Riverflow past BFN (cubic feet per second): 56208 Population Doses Total Body Dose 3.2E-02 man-rem Maximum Organ Dose (organ) 4.11E-02 man-rem (liver)

Population doses can be compared to the natural background dose for the entire 50-mile population of about 70,044 man-rein/year (based on 90 mrem/yr for natural background).

  • Includes dose from abnormal releases.

E-43

BROWNS FERRY NUCLEAR PLANT UNITS 1, 2, AND 3 2013 ANNUAL RADIOACTIVE EFFLUENT RELEASE REPORT RADIOLOGICAL IMPACT Table 5 (Continued)

Page 4 of 4 Doses from Liquid Effluents Fourth Quarter*

Individual Doses (mrem')

Age Group Organ Dose Pathway Dose Quarterly Percent of Limit Limit Adult Total Body Fish Ingestion 1.5E-05 Recreation

2. 1 E-06 Water Ingestion 1.6E-05 Total 3.3E-05 1.5 mrem

< 1 %

Child Bone Fish Ingestion 2.1 E-05 Recreation 2.1 E-06 Water Ingestion 2.2E-05 Total 4.5E-05 5 mrem

< 1 %

Child Thyroid Fish Ingestion 2.6E-07 Recreation 2.1 E-06 Water Ingestion 2.IE-05 Total 2.3E-05 5 mrem

< 1 %

Average Riverflow past BFN (cubic feet per second): 50773 PopuIation Doses Total Body Dose 4.9E-04 man-rem Maximum Organ Dose (organ) 5.4E-04 man-rem (bone)

Population doses can be compared to the natural background dose for the entire 50-mile population of about 70,044 man-rem/year (based on 90 mremlyr for natural background).

  • Includes dose from abnormal releases.

E-44

BROWNS FERRY NUCLEAR PLANT UNITS 1, 2, AND 3 2013 ANNUAL RADIOACTIVE EFFLUENT RELEASE REPORT RADIOLOGICAL IMPACT Table 5A Page 1 of 1 Total Dose from 1-131 Water Ingestion Pathway Quarter 1

2 3

4 Totals 1-131 Ci 7.OE-04 6.8E-04 0.OOE+00 0.OOE+00 1.4E-03 Infant/Thyroid (mrem) 1.1E-04 1.5E-04 0.OOE+00 0.OOE+00 2.6E-04 Population/Thyroid 9.1E-04 1.2E-03 0.OOE+00 O.OOE+00 2.1E-03 (mrem)

Doses from 1-131 Water Ingestion Pathway The REMP requirements as specified in Table 3.12-1 from NUREG 1302, "Offsite Dose Calculation Manual Guidance: Standard Radiological Effluent Controls for Boiling Water Reactors," dated April 1991, requires an 1-131 specific analysis for drinking water pathway samples if the annual dose from 1-131 is greater than 1 mrem. In order to evaluate the need for implementation of this additional analysis, the drinking water pathway dose from 1-131 to the maximum organ and age group was calculated. The results reported here confirm that the drinking water pathway dose from 1-131 was less than the 1 mrem limit and that the performance of the 1-131 specific analysis is not required for BFN REMP drinking water samples.

E-45

BROWNS FERRY NUCLEAR PLANT UNITS 1, 2, AND 3 2013 ANNUAL RADIOACTIVE EFFLUENT RELEASE REPORT RADIOLOGICAL IMPACT Table 6 Page 1 of I Total Dose from Fuel Cycle First Second Third Fourth Dose Quarter Quarter Quarter Quarter Total Body or any Organ (except thyroid)

Total body air submersion 1.3E-03 5.OE-04 1.7E-03 3.3E-04 Critical organ dose (air) 1.6E-02 1.9E-02 3.7E-02 3.OE-02 Total body dose (liquid) 3.1E-02 3.OE-02 2.2E-03 3.3E-05 Maximum organ dose (liquid) 4.7E-02 4.4E-02 3.2E-03 4.5E-05 Direct Radiation Dose O.OE+00 O.OE+00 O.OE+00 O.OE+00 Total 9.5E.02 9.4E-02 4.4E-02 3.OE-02 Cumulative Total Dose 2.6E-01 (mrem)

(Total body or any other organ)

Annual Dose Limit (mrem) 2.5E+01 Percent of Limit 1%

Thyroid Dose (mrem)

Total body air submersion 1.3E-03 5.OE-04 1.7E-03 3.3E-04 Thyroid dose (airborne) 1.2E-02 1.OE-02 1.9E-02 2.2E-02 Total body dose (liquid) 3.1E-02 3.OE-02 2.2E-03 3.3E-05 Thyroid dose (liquid) 5.OE-03 8.OE-03 5.OE-04 2.3E-05 Direct Radiation Dose O.OE+00 O.OE+00 O.OE+00 O.OE+00 Total 4.9E-02 4.9E-02 2.3E-02 2.2E-02 Cumulative Total Dose (Thyroid) mrem 1.4E-01 Annual Dose Limit (mrem) 7.5E+01 Percent of Limit

<1%

E-46

BROWNS FERRY NUCLEAR PLANT UNITS 1, 2, AND 3 2013 ANNUAL RADIOACTIVE EFFLUENT RELEASE REPORT BROWNS FERRY NUCLEAR PLANT 2013 METEOROLOGICAL DATA TABLE 7A JOINT FREQUENCY DISTRIBUTION IN PERCENT FOR GROUND LEVEL RELEASES FIRST QUARTER E-47

BROWNS FERRY NUCLEAR PLANT UNITS 1, 2, AND 3 2013 ANNUAL RADIOACTIVE EFFLUENT RELEASE REPORT JOINT PERCENTAGE FREQUENCIES OF WIND SPEED BY WIND DIRECTION FOR STABILITY CLASS A (DELTA T<=-1.9 C/100 M)

BROWNS FERRY NUCLEAR PLANT JAN 1, 2013 -

MAR 31, 2013 WIND DIRECTION N

NNE NE ENE E

ESE SE SSE S

SSW SW WSW W

WNW NW NNW SUBTOTAL WIND SPEED(MPH) 0.6-1.4 1.5-3.4 3.5-5.4 5.5-7.4 7.5-12.4 12.5-18.4 18.5-24.4 CALM 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000

>=24.5 TOTAL 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.047 0.140 0.093 0.000 0.000 0.000 0.000 0.000 0.000 0.280 0.000 0.000 0.000 0.000 0.093 0.000 0.747 0.420 0.607 0.420 0.280 0.140 0.000 0.000 0.000 0.000 2.709 0.000 0.000 0.000 0.047 0.000 0.047 0.093 0.000 0.140 0.047 0.000 0.000 0.000 0.000 0.000 0.000 0.374 0.280 0.234 0.000 0.000 0.000 0.047 0.000 0.000 0.093 0.000 0.047 0.047 0.000 0.234 0.047 0.140 1.168 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.280 0.327 0.093 0.701 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.280 0.234 0.000 0.047 0.093 0.093 0.841 0.467 0.981 0.560 0.327 0.187 0.000 0.514 0.374 0.234 5.231 TOTAL HOURS OF VALID STABILITY OBSERVATIONS TOTAL HOURS OF STABILITY CLASS A TOTAL TOTAL TOTAL HOURS HOURS HOURS OF VALID WIND DIRECTION-WIND SPEED-STABILITY CLASS A OF VALID WIND DIRECTION-WIND SPEED-STABILITY OBSERVATIONS CALM 2141 112 112 2141 0

METEOROLOGICAL FACILITY:

BROWNS FERRY NUCLEAR PLANT STABILITY BASED ON DELTA-T BETWEEN 10.03 AND 45.30 METERS WIND SPEED AND DIRECTION MEASURED AT 10.50 METER LEVEL DATE PRINTED: 2013/05/22 MEAN WIND SPEED =

6.82 NOTE:

TOTALS AND SUBTOTALS ARE OBTAINED FROM UNROUNDED NUMBERS E-48

BROWNS FERRY NUCLEAR PLANT UNITS 1, 2, AND 3 2013 ANNUAL RADIOACTIVE EFFLUENT RELEASE REPORT JOINT PERCENTAGE FREQUENCIES OF WIND SPEED BY WIND DIRECTION FOR STABILITY CLASS B

(-1.9< DELTA T<=-1.7 C/100 M)

BROWNS FERRY NUCLEAR PLANT JAN 1, 2013 -

MAR 31, 2013 WIND DIRECTION N

NNE NE ENE E

ESE SE SSE S

SSW SW WSW W

WNW NW NNW SUBTOTAL WIND SPEED(MPH) 0.6-1.4 1.5-3.4 3.5-5.4 5.5-7.4 7.5-12.4 12.5-18.4 CALM 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 18.5-24.4

>=24.5 TOTAL 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.047 0.140 0.093 0.140 0.000 0.000 0.000 0.000 0.000 0.000 0.420 0.000 0.000 0.000 0.000 0.047 0.000 0.140 0.000 0.093 0.234 0.000 0.093 0.000 0.000 0.000 0.000 0.607 0.093 0.374 0.047 0.047 0.000 0.000 0.000 0.000 0.000 0.000 0.047 0.047 0.000 0.047 0.000 0.047 0.747 0.000 0.000 0.000 0.000 0.000 0.047 0.000 0.000 0.000 0.000 0.000 0.047 0.047 0.701 0.374 0.140 1.355 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.187 0.093 0.047 0.327 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.093 0.374 0.047 0.047 0.047 0.047 0.187 0.140 0.187 0.374 0.047 0.187 0.047 0.934 0.467 0.234 3.456 TOTAL HOURS OF VALID STABILITY OBSERVATIONS TOTAL HOURS OF STABILITY CLASS B TOTAL TOTAL TOTAL HOURS HOURS HOURS OF VALID WIND DIRECTION-WIND SPEED-STABILITY CLASS B

OF VALID WIND DIRECTION-WIND SPEED-STABILITY OBSERVATIONS CALM 2141 74 74 2141 0

METEOROLOGICAL FACILITY:

BROWNS FERRY NUCLEAR PLANT STABILITY BASED ON DELTA-T BETWEEN 10.03 AND 45.30 METERS WIND SPEED AND DIRECTION MEASURED AT 10.50 METER LEVEL MEAN WIND SPEED =

7.75 NOTE:

TOTALS AND SUBTOTALS ARE OBTAINED FROM UNROUNDED NUMBERS DATE PRINTED: 2013/05/22 E-49

BROWNS FERRY NUCLEAR PLANT UNITS 1, 2, AND 3 2013 ANNUAL RADIOACTIVE EFFLUENT RELEASE REPORT JOINT PERCENTAGE FREQUENCIES OF WIND SPEED BY WIND DIRECTION FOR STABILITY CLASS C

(-1.7< DELTA T<=-1.5 C/100 M)

BROWNS FERRY NUCLEAR PLANT JAN 1,

2013 -

MAR 31, 2013 WIND DIRECTION N

NNE NE ENE E

ESE SE SSE S

SSW SW WSW W

WNW NW NNW SUBTOTAL WIND SPEED(MPH) 0.6-1.4 1.5-3.4 3.5-5.4 5.5-7.4 CALM 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 7.5-12.4 12.5-18.4 18.5-24.4

>=24.5 TOTAL 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.047 0.093 0.047 0.093 0.093 0.000 0.000 0.000 0.000 0.000 0.374 0.187 0.187 0.047 0.000 0.000 0.047 0.140 0.000 0.093 0.140 0.140 0.093 0.093 0.047 0.000 0.047 1.261 0.000 0.047 0.000 0.000 0.047 0.047 0.000 0.000 0.000 0.000 0.047 0.140 0.140 0.140 0.093 0.093 0.794 0.093 0.187 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.047 0.140 0.514 0.514 0.234 1.728 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000

0. 047 0.187 0.374 0.047 0.654 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.047 0.000 0.000 0.047 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.280 0.420 0.047 0.000 0.047 0.093 0.187 0.093 0.140 0.234 0.280 0.280 0.420 0.934 0.981 0.420 4.858 TOTAL HOURS OF VALID STABILITY OBSERVATIONS TOTAL HOURS OF STABILITY CLASS C TOTAL TOTAL TOTAL HOURS HOURS HOURS OF VALID WIND DIRECTION-WIND SPEED-STABILITY CLASS C OF VALID WIND DIRECTION-WIND SPEED-STABILITY OBSERVATIONS CALM 2141 104 104 2141 0

METEOROLOGICAL FACILITY:

BROWNS FERRY NUCLEAR PLANT STABILITY BASED ON DELTA-T BETWEEN 10.03 AND 45.30 METERS WIND SPEED AND DIRECTION MEASURED AT 10.50 METER LEVEL DATE PRINTED: 2013/05/22 MEAN WIND SPEED =

7.76 NOTE:

TOTALS AND SUBTOTALS ARE OBTAINED FROM UNROUNDED NUMBERS E-50

BROWNS FERRY NUCLEAR PLANT UNITS 1, 2, AND 3 2013 ANNUAL RADIOACTIVE EFFLUENT RELEASE REPORT JOINT PERCENTAGE FREQUENCIES OF WIND SPEED BY WIND DIRECTION FOR STABILITY CLASS D

(-1.5< DELTA T<=-0.5 C/100 M)

BROWNS FERRY NUCLEAR PLANT JAN 1, 2013 -

MAR 31, 2013 WIND DIRECTION N

NNE NE ENE E

ESE SE SSE S

SSW SW WSW W

WNW NW NNW SUBTOTAL WIND SPEED(MPH) 0.6-1.4 1.5-3.4 3.5-5.4 5.5-7.4 7.5-12.4 12.5-18.4 18.5-24.4 CALM 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000

>=24.5 TOTAL 0.000 0.000 0.000 0.000 0.000 0.047 0.000 0.047 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.093 0.187 0.467 0.607 0.374 0.420 0.327 0.280 0.794 0.514 0.701 0.607 0.560 0.093 0.047 0.093 0.000 6.072 0.934 1.028 0.934 0.467 0.887 0.794 0.794 0.093 0.047 0.234 0.047 0.701 0.654 0.514 0.560 0.607 9.295 1.261 0.467 0.420 0.327 0.187 0.467 0.327 0.000 0.093 0.140 0.327 0.654 0.841 0.607 0.747 1.214 8.080 0.887 0.327 0.140 0.000 0.000 0.280 0.140 0.000 0.000 0.000 0.047 0.187 0.467 1.308 2.849 1.074 7.707 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.140 1.074 2.008 0.420 3.643 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.047 0.607 0.280 0.000 0.934 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.047 0.000 3.270 2.289 2.102 1.168 1.495 1.915 1.541 0.934 0.654 1.074 1.028 2.102 2.242 4.157 6.586 3.316 0.047 35.871 TOTAL HOURS OF VALID STABILITY OBSERVATIONS TOTAL HOURS OF STABILITY CLASS D TOTAL TOTAL TOTAL HOURS HOURS HOURS OF VALID WIND DIRECTION-WIND SPEED-STABILITY CLASS D OF VALID WIND DIRECTION-WIND SPEED-STABILITY OBSERVATIONS CALM 2141 768 768 2141 0

METEOROLOGICAL FACILITY:

BROWNS FERRY NUCLEAR PLANT STABILITY BASED ON DELTA-T BETWEEN 10.03 AND 45.30 METERS WIND SPEED AND DIRECTION MEASURED AT 10.50 METER LEVEL DATE PRINTED: 2013/05/22 MEAN WIND SPEED =

7.19 NOTE:

TOTALS AND SUBTOTALS ARE OBTAINED FROM UNROUNDED NUMBERS E-51

BROWNS FERRY NUCLEAR PLANT UNITS 1, 2, AND 3 2013 ANNUAL RADIOACTIVE EFFLUENT RELEASE REPORT JOINT PERCENTAGE FREQUENCIES OF WIND SPEED BY WIND DIRECTION FOR STABILITY CLASS E

(-0.5< DELTA T<= 1.5 C/100 M)

BROWNS FERRY NUCLEAR PLANT JAN 1, 2013 -

MAR 31, 2013 WIND DIRECTION WIND SPEED(MPH) 0.6-1.4 1.5-3.4 3.5-5.4 5.5-7.4 N

NNE NE ENE E

ESE SE SSE S

SSW SW WSW W

WNW NW NNW CALM 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 7.5-12.4 12.5-18.4 18.5-24.4 0.234 0.093 0.000 0.093 0.093 0.093 0.047

0. 093 0.093 0.234 0.140 0.047 0.047 0.047 0.093 0.047 0.981 0.701 0.327 0.280 0.374 0.747 0.841 1.448 1.541 0.981 0.514 1.028 0.327 0.187 0.374 0.701 0.934 1.261 0.701 0.374 0.420 1.121 1.401 0.467 0.514 0.234 0.234 0.234 0.280 0.093 0.187 1.355 9.809 0.747 0.187 0.374 0.000 0.093 0.187 0.701 0.047 0.747 0.047 0.047 0.093 0.234 0.140 0.701 0.747 5.091 0.140 0.140 0.234 0.047 0.000 0.000 0.047 0.000 0.327 0.280 0.047 0.000 0.047 0.187 0.467 0.841 2.802 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.093 0.140 0.093 0.000 0.327 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.093 0.000 0.000 0.093 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000

>=24.5 TOTAL 3.036 2.382 1.635 0.794 0.981 2.149 3.036 2.055 3.223 1.775 0.981 1.401 1.028 0.887 1.915 3.690 SUBTOTAL 1.495 11.350 0.000 30.967 TOTAL HOURS OF VALID STABILITY OBSERVATIONS TOTAL HOURS OF STABILITY CLASS E TOTAL TOTAL TOTAL HOURS HOURS HOURS OF VALID WIND DIRECTION-WIND SPEED-STABILITY CLASS E OF VALID WIND DIRECTION-WIND SPEED-STABILITY OBSERVATIONS CALM 2141 663 663 2141 0

METEOROLOGICAL FACILITY:

BROWNS FERRY NUCLEAR PLANT STABILITY BASED ON DELTA-T BETWEEN 10.03 AND 45.30 METERS WIND SPEED AND DIRECTION MEASURED AT 10.50 METER LEVEL DATE PRINTED: 2013/05/22 MEAN WIND SPEED =

4.41 NOTE:

TOTALS AND SUBTOTALS ARE OBTAINED FROM UNROUNDED NUMBERS E-52

BROWNS FERRY NUCLEAR PLANT UNITS 1, 2, AND 3 2013 ANNUAL RADIOACTIVE EFFLUENT RELEASE REPORT JOINT PERCENTAGE FREQUENCIES OF WIND SPEED BY WIND DIRECTION FOR STABILITY CLASS F

( 1.5< DELTA T<= 4.0 C/100 M)

BROWNS FERRY NUCLEAR PLANT JAN 1, 2013 -

MAR 31, 2013 WIND DIRECTION WIND SPEED(MPH) 0.6-1.4 1.5-3.4 3.5-5.4 5.5-7.4 N

NNE NE ENE E

ESE SE SSE S

SSW SW WSW W

WNW NW NNW CALM 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 7.5-12.4 12.5-18.4 18.5-24.4 0.047 0.000 0.093 0.047 0.093 0.093 0.047 0.187 0.093 0.047 0.000 0.000 0.000 0.047 0.187 0.000 0.981 0.981 0.280 0.327 0.234 0.467 0.701 0.701 0.794 0.794 0.420 0.234 0.140 0.140 0.047 0.234 0.560 7.053 0.467 0.140 0.093 0.000 0.047 0.093 0.374 0.234 1.121 0.187 0.140 0.000 0.000 0.000 0.047 0.374 3.316 0.000 0.000 0.000 0.000 0.000 0.000 0.093 0.000 0.327 0.047 0.000 0.000 0.000 0.000 0.000 0.187 0.654 0.000 0.000 0.000 0.000 0.000 0.000 0.093 0.000 0.327 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.420

>=24.5 TOTAL 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.047 0.000 0.000 0.047 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 1.495 0.420 0.514 0.280 0.607 0.887 1.308 1.214 2.662 0.701 0.374 0.140 0.140 0.140 0.467 1.121 SUBTOTAL 0.000 12.471 TOTAL HOURS OF VALID STABILITY OBSERVATIONS TOTAL HOURS OF STABILITY CLASS F TOTAL TOTAL TOTAL HOURS HOURS HOURS OF VALID WIND DIRECTION-WIND SPEED-STABILITY CLASS F OF VALID WIND DIRECTION-WIND SPEED-STABILITY OBSERVATIONS CALM 2141 267 267 2141 0

METEOROLOGICAL FACILITY:

BROWNS FERRY NUCLEAR PLANT STABILITY BASED ON DELTA-T BETWEEN 10.03 AND 45.30 METERS WIND SPEED AND DIRECTION MEASURED AT 10.50 METER LEVEL DATE PRINTED: 2013/05/22 MEAN WIND SPEED =

3.30 NOTE:

TOTALS AND SUBTOTALS ARE OBTAINED FROM UNROUNDED NUMBERS E-53

BROWNS FERRY NUCLEAR PLANT UNITS 1, 2, AND 3 2013 ANNUAL RADIOACTIVE EFFLUENT RELEASE REPORT JOINT PERCENTAGE FREQUENCIES OF WIND SPEED BY WIND DIRECTION FOR STABILITY CLASS G (DELTA T > 4.0 C/100 M)

BROWNS FERRY NUCLEAR PLANT JAN 1, 2013 -

MAR 31, 2013 WIND DIRECTION N

NNE NE ENE E

ESE SE SSE S

SSW SW WSW W

WNW NW NNW SUBTOTAL WIND SPEED(MPH) 0.6-1.4 1.5-3.4 3.5-5.4 5.5-7.4 CALM 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 7.5-12.4 12.5-18.4 18.5-24.4

>=24.5 TOTAL 0.093 0.047 0.047 0.047 0 000 0.047 0.187 0.234 0.000 0.000 0.047 0.047 0.000 0.047 0.140 0.093 1.074 0.607 0.140 0.140 0.234 0.093 0.047 0.747 1.074 1.214 0.093 0.047 0.047 0.000 0.000 0.140 0.280 4.904 0.000 0.047 0.000 0.000 0.000 0.000 0.000 0.187 0.420 0.000 0.000 0.000 0.000 0.000 0.000 0.047 0.701 0.000 0.000 0.000 0.000 0.000 0.000 0.047 0.000 0.374 0.000 0.047 0.000 0.000 0.000 0.000 0.000 0.467 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.701 0.234 0.187 0.280 0.093 0.093 0.981 1.495 2.008 0.093 0.140 0.093 0.000 0.047 0.280 0.420 7.146 TOTAL HOURS OF VALID STABILITY OBSERVATIONS TOTAL HOURS OF STABILITY CLASS G TOTAL TOTAL TOTAL HOURS HOURS HOURS OF VALID WIND DIRECTION-WIND SPEED-STABILITY CLASS G OF VALID WIND DIRECTION-WIND SPEED-STABILITY OBSERVATIONS CALM 2141 153 153 2141 0

METEOROLOGICAL FACILITY:

BROWNS FERRY NUCLEAR PLANT STABILITY BASED ON DELTA-T BETWEEN 10.03 AND 45.30 METERS WIND SPEED AND DIRECTION MEASURED AT 10.50 METER LEVEL DATE PRINTED: 2013/05/22 MEAN WIND SPEED =

2.54 NOTE:

TOTALS AND SUBTOTALS ARE OBTAINED FROM UNROUNDED NUMBERS E-54

BROWNS FERRY NUCLEAR PLANT UNITS 1, 2, AND 3 2013 ANNUAL RADIOACTIVE EFFLUENT RELEASE REPORT BROWNS FERRY NUCLEAR PLANT 2013 METEOROLOGICAL DATA TABLE 7B JOINT FREQUENCY DISTRIBUTION IN PERCENT FOR GROUND LEVEL RELEASES SECOND QUARTER E-55

BROWNS FERRY NUCLEAR PLANT UNITS 1, 2, AND 3 2013 ANNUAL RADIOACTIVE EFFLUENT RELEASE REPORT JOINT PERCENTAGE FREQUENCIES OF WIND SPEED BY WIND DIRECTION FOR STABILITY CLASS A (DELTA T<=-l.9 C/100 M)

Browns Ferry Nuclear Plant STA 52 D -

Validated Edited Data APR 1, 2013 -

JUN 30, 2013 WIND DIRECTION N

NNE NE ENE E

ESE SE SSE S

SSW SW WSW W

WNW NW NNW SUBTOTAL WIND SPEED(MPH) 0.6-1.4 1.5-3.4 3.5-5.4 5.5-7.4 CALM 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 7.5-12.4 12.5-18.4 18.5-24.4

>=24.5 TOTAL 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.153 0.459 1.071 1.122 0.255 0.000 0.000 0.000 0.000 0.000 0.000 3.060 0.051 0.000 0.000 0.000 0.051 0.153 1.173 0.357 0.204 0.204 0.051 0.102 0.000 0.051 0.000 0.000 2.397 0.051 0.000 0.000 0.000 0.000 0.051 0.051 0.000 0.000 0.051 0.000 0.000 0.000 0.000 0.000 0.000 0.204 0.255 0.306 0.051 0.000 0.000 0.153 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.102 0.153 0.051 1.071 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000

0. 153 0.000 0.153 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.357 0.306 0.051 0.000 0.051 0.510 1.683 1.428 1.326 0.510 0.051 0.102 0.000 0.153 0.306 0.051 6.884 TOTAL HOURS OF VALID STABILITY OBSERVATIONS TOTAL HOURS OF STABILITY CLASS A TOTAL HOURS OF VALID WIND DIRECTION-WIND SPEED-STABILITY CLASS A TOTAL HOURS OF VALID WIND DIRECTION-WIND SPEED-STABILITY OBSERVATIONS TOTAL HOURS CALM METEOROLOGICAL FACILITY:

Browns Ferry Nuclear Plant STA 52 D -

Validated STABILITY BASED ON DELTA-T BETWEEN 10.03 AND 45.30 METERS WIND SPEED AND DIRECTION MEASURED AT 10.50 METER LEVEL MEAN WIND SPEED =

4.66 NOTE:

TOTALS AND SUBTOTALS ARE OBTAINED FROM UNROUNDED NUMBERS 1982 137 135 1961 0

Edited Data DATE PRINTED: 2013/08/12 E-56

BROWNS FERRY NUCLEAR PLANT UNITS 1, 2, AND 3 2013 ANNUAL RADIOACTIVE EFFLUENT RELEASE REPORT JOINT PERCENTAGE FREQUENCIES OF WIND SPEED BY WIND DIRECTION FOR STABILITY CLASS B

(-1.9< DELTA T<=-1.7 C/100 M)

Browns Ferry Nuclear Plant STA 52 D -

Validated Edited Data APR 1, 2013 -

JUN 30, 2013 WIND DIRECTION N

NNE NE ENE E

ESE SE SSE S

SSW SW WSW W

WNW NW NNW SUBTOTAL WIND SPEED(MPH) 0.6-1.4 1.5-3.4 3.5-5.4 5.5-7.4 7.5-12.4 12.5-18.4 CALM 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 18.5-24.4

>=24.5 TOTAL 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.459 0.153 0.408 0.153 0.204 0.051 0.000 0.000 0.000 0.000 1.428 0.000 0.000 0.000 0.000 0.000 0.255 0.204 0.102 0.153 0.102 0.102 0.306 0.000 0.051 0.000 0.000 1.275 0.153 0.102 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.102

0. 102 0.051 0.000 0.102 0.612 0.153 0.153 0.102 0.000 0.000 0.051 0.000 0.000 0.000 0.000 0.000 0.000 0.102 0.255 0.816 0.102 1.734 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.204 0.000 0.000 0.204 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.306 0.255 0.102 0.000 0.000 0.306 0.663 0.255 0.561 0.255 0.306 0.459 0.204 0.561 0.816 0.204 5.252 TOTAL HOURS OF VALID STABILITY OBSERVATIONS TOTAL HOURS OF STABILITY CLASS B TOTAL HOURS OF VALID WIND DIRECTION-WIND SPEED-STABILITY CLASS B TOTAL HOURS OF VALID WIND DIRECTION-WIND SPEED-STABILITY OBSERVAJ TOTAL HOURS CALM 1982 106 103 1961 0

'IONS METEOROLOGICAL FACILITY:

Browns Ferry Nuclear Plant STA 52 D -

Validated STABILITY BASED ON DELTA-T BETWEEN 10.03 AND 45.30 METERS WIND SPEED AND DIRECTION MEASURED AT 10.50 METER LEVEL MEAN WIND SPEED =

6.12 NOTE:

TOTALS AND SUBTOTALS ARE OBTAINED FROM UNROUNDED NUMBERS Edited Data DATE PRINTED: 2013/08/12 E-57

BROWNS FERRY NUCLEAR PLANT UNITS 1, 2, AND 3 2013 ANNUAL RADIOACTIVE EFFLUENT RELEASE REPORT JOINT PERCENTAGE FREQUENCIES OF WIND SPEED BY WIND DIRECTION FOR STABILITY CLASS C

(-1.7< DELTA T<=-1.5 C/100 M)

Browns Ferry Nuclear Plant STA 52 D -

Validated Edited Data APR 1, 2013 -

JUN 30, 2013 WIND DIRECTION N

NNE NE ENE E

ESE SE SSE S

SSW SW WSW W

WNW NW NNW SUBTOTAL WIND SPEED(MPH) 0.6-1.4 1.5-3.4 3.5-5.4 5.5-7.4 7.5-12.4 12.5-18.4 18.5-24.4 CALM 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000

>=24.5 TOTAL 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.051 0.000 0.000 0.000 0.204 0.408 0.357 0.357 0.357 0.255 0.255 0.000 0.000 0.000 0.000 2.244 0.102 0.051 0.000 0.000 0.051 0.051 0.153 0.102 0.153 0.255 0.051 0.204 0.306 0.255 0.000 0.000 1.734 0.204 0.153 0.000 0.000 0.000 0.153 0.000 0.000 0.051 0.000 0.000 0.000 0.306 0.255 0.051 0.051 1.224 0.204 0.102 0.153 0.000 0.000 0.051 0.000 0.000 0.000 0.000 0.000 0.000 0.306 0.408 0.255 0.153 1.632 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.051 0.000 0.051 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.510 0.357 0.153 0.000 0.051 0.459 0.561 0.459 0.561 0.612 0.306 0.459 0.918 0.918 0.357 0.204 6.884 TOTAL HOURS OF VALID STABILITY OBSERVATIONS TOTAL HOURS OF STABILITY CLASS C TOTAL HOURS OF VALID WIND DIRECTION-WIND SPEED-STABILITY CLASS C TOTAL HOURS OF VALID WIND DIRECTION-WIND SPEED-STABILITY OBSERVATIONS TOTAL HOURS CALM METEOROLOGICAL FACILITY:

Browns Ferry Nuclear Plant STA 52 D -

Validated STABILITY BASED ON DELTA-T BETWEEN 10.03 AND 45.30 METERS WIND SPEED AND DIRECTION MEASURED AT 10.50 METER LEVEL MEAN WIND SPEED =

5.41 NOTE:

TOTALS AND SUBTOTALS ARE OBTAINED FROM UNROUNDED NUMBERS 1982 135 135 1961 0

Edited Data DATE PRINTED: 2013/08/12 E-58

BROWNS FERRY NUCLEAR PLANT UNITS 1, 2, AND 3 2013 ANNUAL RADIOACTIVE EFFLUENT RELEASE REPORT JOINT PERCENTAGE FREQUENCIES OF WIND SPEED BY WIND DIRECTION FOR STABILITY CLASS D

(-1.5< DELTA T<=-0.5 C/100 M)

Browns Ferry Nuclear Plant STA 52 D -

Validated Edited Data APR 1, 2013 -

JUN 30, 2013 WIND DIRECTION N

NNE NE ENE E

ESE SE SSE S

SSW SW WSW W

WNW NW NNW SUBTOTAL WIND SPEED(MPH) 0.6-1.4 1.5-3.4 3.5-5.4 5.5-7.4 7.5-12.4 12.5-18.4 CALM 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 18.5-24.4

>=24.5 TOTAL 0.051 0.000 0.000 0.000 0.000 0.000 0.000 0.051 0.000 0.000 0.153 0.000 0.000 0.000 0.000 0.051 0.102 0.051 0.306 0.204 0.408 0.561 1.479 2.040 2.448 1.530 1.071 0.918 0.765 0.051 0.000 0.204 0.612 0.255 0.306 0.204 0.000 1.224 0.204 0.051 0.459 0.459 0.102 1.020 1.683 0.357 0.918 0.459 8.312 0.255 0.663 0.408 0.102 0.000 0.459 0.000 0.000 0.255 0.102 0.000 0.102 0.867 0.969 0.765 0.204 5.150 0.000 0.306 0.255 0.102 0.000 0.204 0.000 0.000 0.000 0.000 0.000 0.000 0.459 1.683 1.071 0.408 4.488 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.255 0.153 0.000 0.408 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 1.020 1.275 1.275 0.612 0.408 2.448 1.683 2.142 3.162 2.091 1.326 2.040 3.774 3.315 2.907 1.326 0.306 12.137 0.000 30.801 TOTAL HOURS OF VALID STABILITY OBSERVATIONS TOTAL HOURS OF STABILITY CLASS D TOTAL TOTAL TOTAL HOURS HOURS HOURS OF VALID WIND DIRECTION-WIND SPEED-STABILITY CLASS D OF VALID WIND DIRECTION-WIND SPEED-STABILITY OBSERVATIONS CALM 1982 609 604 1961 0

METEOROLOGICAL FACILITY:

Browns Ferry Nuclear Plant STA 52 D -

Validated STABILITY BASED ON DELTA-T BETWEEN 10.03 AND 45.30 METERS WIND SPEED AND DIRECTION MEASURED AT 10.50 METER LEVEL MEAN WIND SPEED =

4.77 NOTE:

TOTALS AND SUBTOTALS ARE OBTAINED FROM UNROUNDED NUMBERS Edited Data DATE PRINTED: 2013/08/12 E-59

BROWNS FERRY NUCLEAR PLANT UNITS 1, 2, AND 3 2013 ANNUAL RADIOACTIVE EFFLUENT RELEASE REPORT JOINT PERCENTAGE FREQUENCIES OF WIND SPEED BY WIND DIRECTION FOR STABILITY CLASS E

(-0.5< DELTA T<= 1.5 C/100 M)

Browns Ferry Nuclear Plant STA 52 D -

Validated Edited Data APR 1, 2013 -

JUN 30, 2013 WIND DIRECTION WIND SPEED(MPH) 0.6-1.4 1.5-3.4 3.5-5.4 5.5-7.4 N

NNE NE ENE E

ESE SE SSE S

SSW SW WSW W

WNW NW NNW CALM 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 7.5-12.4 12.5-18.4 18.5-24.4 0.051 0.153 0.102 0.306 0.255 0.102 0.408 0.306 0.357 0.255 0.153 0.102 0.204 0.000 0.051 0.000 0.714 0.408 0.255 0.357 2.244 1.785 1.683 1.071 2.142 0.765 0.612 0.816 1.071 0.408 0.051 0.612 0.306 0.612 0.102 0.408 0.816 1.581 0.204 0.000 0.459 0.153 0.051 0.153 0.663 0.204 0.153 0.663 6.527 0.153 0.255 0.408 0.204 0.561 0.255 0.000 0.000 0.102 0.102 0.051 0.051 0.255 0.102 0.153 0.357 3.009 0.051 0.102 0.102 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.255 0.153 0.102 0.765

>=24.5 TOTAL 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.051 0.051 0.000 0.102 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 1.275 1.530 0.969 1.275 3.876 3.723 2.295 1.377 3.060 1.275 0.867 1.122 2.193 1.020

0. 612 1.734 SUBTOTAL 2.805 14.992 0.000 28.200 TOTAL HOURS OF VALID STABILITY OBSERVATIONS TOTAL HOURS OF STABILITY CLASS E TOTAL HOURS OF VALID WIND DIRECTION-WIND SPEED-STABILITY CLASS E TOTAL HOURS OF VALID WIND DIRECTION-WIND SPEED-STABILITY OBSERVATIONS TOTAL HOURS CALM METEOROLOGICAL FACILITY:

Browns Ferry Nuclear Plant STA 52 D -

Validated STABILITY BASED ON DELTA-T BETWEEN 10.03 AND 45.30 METERS WIND SPEED AND DIRECTION MEASURED AT 10.50 METER LEVEL MEAN WIND SPEED =

3.34 NOTE:

TOTALS AND SUBTOTALS ARE OBTAINED FROM UNROUNDED NUMBERS 1982 564 553 1961 0

Edited Data DATE PRINTED: 2013/08/12 E-60

BROWNS FERRY NUCLEAR PLANT UNITS 1, 2, AND 3 2013 ANNUAL RADIOACTIVE EFFLUENT RELEASE REPORT JOINT PERCENTAGE FREQUENCIES OF WIND SPEED BY WIND DIRECTION FOR STABILITY CLASS F

( 1.5< DELTA T<= 4.0 C/100 M)

Browns Ferry Nuclear Plant STA 52 D -

Validated Edited Data APR 1, 2013 -

JUN 30, 2013 WIND DIRECTION N

NNE NE ENE E

ESE SE SSE S

SSW SW WSW W

WNW NW NNW SUBTOTAL WIND SPEED(MPH) 0.6-1.4 1.5-3.4 3.5-5.4 5.5-7.4 7.5-12.4 12.5-18.4 18.5-24.4 CALM 0.006 0.002 0.001 0.005 0.007 0.004 0.005 0.005 0.007 0.002 0.001 0.000 0.001 0.000 0.001 0.002 0.051

>=24.5 TOTAL 0.306 0.204 0.153 0.408 0.510 0.408 0.714 0.306 0.255 0.102 0.153 0.051 0.102 0.051 0.153 0.102 3.978 0.918 0.204 0.153 0.765 1.020 0.510 0.306 0.765 1.377 0.306 0.153 0.051 0.102 0.051 0.102 0.357 7.139 0.051 0.255 0.000 0.153 0.306 0.051 0.000 0.000 0.306 0.051 0.000 0.000 0.051 0.102 0.000 0.255 1.581 0.102 0.102 0.051 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.051 0.306 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.153 0.000 0.000 0.153 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 1.382 0.767 0.358 1.331 1.843

0. 973 1.025 1.076 1.945 0.461 0.307 0.102 0.256 0.357 0.256 0.767 0.000 13.208 TOTAL HOURS OF VALID STABILITY OBSERVATIONS TOTAL HOURS OF STABILITY CLASS F TOTAL TOTAL TOTAL HOURS HOURS HOURS OF VALID WIND DIRECTION-WIND SPEED-STABILITY CLASS F OF VALID WIND DIRECTION-WIND SPEED-STABILITY OBSERVATIONS CALM 1982 259 259 1961 1

METEOROLOGICAL FACILITY:

Browns Ferry Nuclear Plant STA 52 D -

Validated Edited Data STABILITY BASED ON DELTA-T BETWEEN 10.03 AND 45.30 METERS WIND SPEED AND DIRECTION MEASURED AT 10.50 METER LEVEL DATE PRINTED: 2013/08/12 MEAN WIND SPEED =

2.40 NOTE:

TOTALS AND SUBTOTALS ARE OBTAINED FROM UNROUNDED NUMBERS E-61

BROWNS FERRY NUCLEAR PLANT UNITS 1, 2, AND 3 2013 ANNUAL RADIOACTIVE EFFLUENT RELEASE REPORT JOINT PERCENTAGE FREQUENCIES OF WIND SPEED BY WIND DIRECTION FOR STABILITY CLASS G (DELTA T > 4.0 C/100 M)

Browns Ferry Nuclear Plant STA 52 D -

Validated Edited Data APR 1, 2013 -

JUN 30, 2013 WIND DIRECTION N

NNE NE ENE E

ESE SE SSE S

SSW SW WSW W

WNW NW NNW SUBTOTAL WIND SPEED(MPH) 0.6-1.4 1.5-3.4 3.5-5.4 5.5-7.4 CALM 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 7.5-12.4 12.5-18.4 18.5-24.4

>=24.5 TOTAL 0.408 0.102 0.408 0.051 0.510 0.255 0.408 1.020 0.204 0.204 0.153 0.051 0.000 0.102 0.051 0.561 4.488 0.561 0.153 0.204 0.408 0.153 0.102 0.153 0.612 0.612 0.102 0.000 0.051 0.000 0.000 0.102 0.561 3.774 0.102 0.102 0.051 0.102 0.102 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.459 0.000 0.000 0.000 0.051 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.051 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 1.071 0.357 0.663 0.612 0.765 0.357 0.561 1.632 0.816 0.306 0.153 0.102 0.000 0.102 0.153 1.122 8.771 TOTAL HOURS OF VALID STABILITY OBSERVATIONS TOTAL HOURS OF STABILITY CLASS G TOTAL HOURS OF VALID WIND DIRECTION-WIND SPEED-STABILITY CLASS G TOTAL HOURS OF VALID WIND DIRECTION-WIND SPEED-STABILITY OBSERVATIONS TOTAL HOURS CALM METEOROLOGICAL FACILITY:

Browns Ferry Nuclear Plant STA 52 D -

Validated STABILITY BASED ON DELTA-T BETWEEN 10.03 AND 45.30 METERS WIND SPEED AND DIRECTION MEASURED AT 10.50 METER LEVEL MEAN WIND SPEED =

1.71 NOTE:

TOTALS AND SUBTOTALS ARE OBTAINED FROM UNROUNDED NUMBERS 1982 172 172 1961 0

Edited Data DATE PRINTED: 2013/08/12 E-62

BROWNS FERRY NUCLEAR PLANT UNITS 1, 2, AND 3 2013 ANNUAL RADIOACTIVE EFFLUENT RELEASE REPORT JOINT PERCENTAGE FREQUENCIES OF WIND SPEED BY WIND DIRECTION DISREGARDING STABILITY CLASS Browns Ferry Nuclear Plant STA 52 D -

Validated Edited Data APR 1, 2013 -

JUN 30, 2013 WIND DIRECTION N

NNE NE ENE E

ESE SE SSE S

SSW SW WSW W

WNW NW NNW SUBTOTAL WIND SPEED(MPH) 0.6-1.4 1.5-3.4 3.5-5.4 5.5-7.4 7.5-12.4 12.5-18.4 18.5-24.4 CALM 0.003 0.001 0.001 0.002 0.005 0.003 0.005 0.006 0.007 0.003 0.002 0.002 0.002 0.001 0.000 0.002

>=24.5 TOTAL 0.881 0.649 0.788 0.788 1.206 0.696 1.577 1.670 0.788 0.510 0.557 0.186 0.278 0.139 0.232 0.696 2.134 0.928

0. 928 1.670 4.128 3.293 4.870 5.659 8.071 3.340 2.134 1.948 1.763 0.557 0.232 1.623 1.113 1.160 0.464
0. 974 1.531 3.803 2.041 0.696 1.716 1.345 0.371 1.623 2.458 0.928 0.974 1.391 0.928 1.160 1.160 0.417 0.557 2.180 0.046 0.000 0.371 0.232 0.046 0.232 1.438 1.252 0.881 0.835 0.649 0.881 0.603 0.093 0.000 0.649 0.000 0.000 0.000 0.000 0.000 0.000 0.928 2.551 2.226 0.881 9.462 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.835 0.417 0.000 1.252 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 5.708 4.779 3.944 3.945 7.426 10.625 8.540 8.030 10.954 5.430 3.110 3.991 6.866 6.262 4.963 5.429 0.046 11.642 43.275 22.588 11.735 0.000 100.000 TOTAL HOURS OF VALID WIND OBSERVATIONS TOTAL HOURS OF OBSERVATIONS RECOVERABILITY PERCENTAGE TOTAL HOURS CALM 2156 2184 98.7 1

METEOROLOGICAL FACILITY:

Browns Ferry Nuclear Plant STA 52 D -

WIND SPEED AND DIRECTION MEASURED AT 10.50 METER LEVEL MEAN WIND SPEED =

3.95 NOTE:

TOTALS AND SUBTOTALS ARE OBTAINED FROM UNROUNDED NUMBERS Validated Edited Data DATE PRINTED: 2013/08/12 E-63

BROWNS FERRY NUCLEAR PLANT UNITS 1, 2, AND 3 2013 ANNUAL RADIOACTIVE EFFLUENT RELEASE REPORT WIND SPEED (MPH)

CALM 0.6-1.4 1.5-3.4 3.5-5.4 5.5-7.4 7.5-12.4 12.5-18.4 18.5-24.4

>=24.5 TOTAL A

0.000 0.000 3.060 2.397 0.204 1.071 0.153 0.000 0.000 6.884 JOINT PERCENTAGE FREQUENCIES OF WIND SPEED BY STABILITY CLASS Browns Ferry Nuclear Plant STA 52 D -

Validated Edited Data APR 1, 2013 -

JUN 30, 2013 STABILITY CLASS B

C D

E F

0.000 0.000 0.000 0.000 0.051 0.000 0.000 0.306 2.805 3.978 1.428 2.244 12.137 14.992 7.139 1.275 1.734 8.312 6.527 1.581 0.612 1.224 5.150 3.009 0.306 1.734 1.632 4.488 0.765 0.000 0.204 0.051 0.408 0.102 0.153 0.000 0.000 0.000 0.000 0.000 G

0.000 4.488 3.774 0.459 0.051 0.000 0.000 0.000 0.000 8.771 0.000 5.252 0.000 6.884 0.000 30.801 0.000 28.200 0.000 13.208 TOTAL HOURS OF VALID STABILITY OBSERVATIONS TOTAL HOURS OF VALID WIND DIRECTION-WIND SPEED-STABILITY TOTAL HOURS OF OBSERVATIONS JOINT RECOVERABILITY PERCENTAGE 1982 OBSERVATIONS 1961 2184 89.8 METEOROLOGICAL FACILITY:

Browns Ferry Nuclear Plant STA 52 D -

Validated Edited Data STABILITY BASED ON DELTA-T BETWEEN 10.03 AND 45.30 METERS WIND SPEED AND DIRECTION MEASURED AT 10.50 METER LEVEL DATE PRINTED: 2013/08/12 E-64

BROWNS FERRY NUCLEAR PLANT UNITS 1, 2, AND 3 2013 ANNUAL RADIOACTIVE EFFLUENT RELEASE REPORT BROWNS FERRY NUCLEAR PLANT 2013 METEOROLOGICAL DATA TABLE 7C JOINT FREQUENCY DISTRIBUTION IN PERCENT FOR GROUND LEVEL RELEASES THIRD QUARTER E-65

BROWNS FERRY NUCLEAR PLANT UNITS 1, 2, AND 3 2013 ANNUAL RADIOACTIVE EFFLUENT RELEASE REPORT JOINT PERCENTAGE FREQUENCIES OF WIND SPEED BY WIND DIRECTION FOR STABILITY CLASS A (DELTA T<=-1.9 C/100 M)

BROWNS FERRY NUCLEAR PLANT JUL 1, 2013 -

SEP 30, 2013 WIND DIRECTION N

NNE NE ENE E

ESE SE SSE S

SSW SW WSW W

WNW NW NNW SUBTOTAL WIND SPEED(MPH) 0.6-1.4 1.5-3.4 3.5-5.4 5.5-7.4 7.5-12.4 12.5-18.4 CALM 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 18.5-24.4

>=24.5 TOTAL 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.091 0.960 1.372 0.960 0.183 0.091 0.000 0.000 0.000 0.000 0.000 3.658 0.000 0.000 0.000 0.000 0.046 0.503 1.235 0.503 0.137 0.091 0.046 0.137 0.046 0.046 0.000 0.000 2.789 0.046 0.000 0.000 0.000 0.000 0.274 0.000 0.000 0.000 0.000 0.000 0.000 0.274 0.046 0.000 0.091 0.732 0.091 0.091 0.137 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.046 0.229 0.137 0.183 0.914 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.046 0.000 0.000 0.046 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.137 0.091 0.137 0.000 0.046 0.869 2.195 1.875 1.097 0.274 0.137 0.137 0.366 0.366 0.137 0.274 8.139 TOTAL HOURS OF VALID STABILITY OBSERVATIONS TOTAL HOURS OF STABILITY CLASS A TOTAL TOTAL TOTAL HOURS HOURS HOURS OF VALID WIND DIRECTION-WIND SPEED-STABILITY CLASS A OF VALID WIND DIRECTION-WIND SPEED-STABILITY OBSERVATIONS CALM 2188 179 178 2187 0

METEOROLOGICAL FACILITY:

BROWNS FERRY NUCLEAR PLANT STABILITY BASED ON DELTA-T BETWEEN 10.03 AND 45.30 METERS WIND SPEED AND DIRECTION MEASURED AT 10.50 METER LEVEL DATE PRINTED: 2013/11/15 MEAN WIND SPEED =

4.41 NOTE:

TOTALS AND SUBTOTALS ARE OBTAINED FROM UNROUNDED NUMBERS E-66

BROWNS FERRY NUCLEAR PLANT UNITS 1, 2, AND 3 2013 ANNUAL RADIOACTIVE EFFLUENT RELEASE REPORT JOINT PERCENTAGE FREQUENCIES OF WIND SPEED BY WIND DIRECTION FOR STABILITY CLASS B

(-1.9< DELTA T<=-1.7 C/100 M)

BROWNS FERRY NUCLEAR PLANT JUL 1, 2013 -

SEP 30, 2013 WIND DIRECTION N

NNE NE ENE E

ESE SE SSE S

SSW SW WSW W

WNW NW NNW SUBTOTAL WIND SPEED(MPH) 0.6-1.4 1.5-3.4 3.5-5.4 5.5-7.4 CALM 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000

0. 000 0.000 0.000 7.5-12.4 12.5-18.4 18.5-24.4

>=24.5 TOTAL 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.412 0.457 0.274 0.091 0.000 0.000 0.000 0.000 0.000 0.000 1.235 0.091 0.000 0.046 0.000 0.046 0.366 0.183 0.046 0.046 0.000 0.046 0.183 0.183 0.000 0.046 0.000 1.280 0.046 0.183 0.000 0.000 0.000 0.091 0.000 0.000 0.000 0.000 0.000 0.000 0.183 0.046 0.229 0.229 1.006 0.274 0.274 0.091 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.137 0.320 0.183 1.280 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.412 0.457 0.137 0.000 0.046 0.457 0.594 0.503 0.320 0.091 0.046 0.183 0.366 0.183 0.594 0.412 4.801 TOTAL HOURS OF VALID STABILITY OBSERVATIONS TOTAL HOURS OF STABILITY CLASS B TOTAL TOTAL TOTAL HOURS HOURS HOURS OF VALID WIND DIRECTION-WIND SPEED-STABILITY CLASS B OF VALID WIND DIRECTION-WIND SPEED-STABILITY OBSERVATIONS CALM 2188 105 105 2187 0

METEOROLOGICAL FACILITY:

BROWNS FERRY NUCLEAR PLANT STABILITY BASED ON DELTA-T BETWEEN 10.03 AND 45.30 METERS WIND SPEED AND DIRECTION MEASURED AT 10.50 METER LEVEL DATE PRINTED: 2013/11/15 MEAN WIND SPEED =

5.58 NOTE:

TOTALS AND SUBTOTALS ARE OBTAINED FROM UNROUNDED NUMBERS E-67

BROWNS FERRY NUCLEAR PLANT UNITS 1, 2, AND 3 2013 ANNUAL RADIOACTIVE EFFLUENT RELEASE REPORT JOINT PERCENTAGE FREQUENCIES OF WIND SPEED BY WIND DIRECTION FOR STABILITY CLASS C

(-1.7< DELTA T<=-1.5 C/100 M)

BROWNS FERRY NUCLEAR PLANT JUL 1, 2013 -

SEP 30, 2013 WIND DIRECTION N

NNE NE ENE E

ESE SE SSE S

SSW SW WSW W

WNW NW NNW SUBTOTAL WIND SPEED(MPH) 0.6-1.4 1.5-3.4 3.5-5.4 5.5-7.4 7.5-12.4 12.5-18.4 18.5-24.4 CALM 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000

>=24.5 TOTAL 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.137 0.594 0.549 0.960 0.183 0.137 0.229 0.000 0.000 0.000 0.000 2.789 0.229 0.091 0.091 0.091 0.000 0.229 0.091 0.000 0.046 0.137 0.046 0.366 0.777 0.137 0.137 0.183 2.652 0.183 0.274 0.046 0.000 0.046 0.137 0.000 0.000 0.000 0.000 0.000 0.000 0.137 0.091 0.000 0.366 1.280 0.091 0.091 0.046 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.046 0.229 0.137 0.183 0.823 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.503 0.457 0.183 0.091 0.046 0.503 0.686 0.549 1.006 0.320 0.183 0.594 0.960 0.457 0.274 0.732 7.545 TOTAL HOURS OF VALID STABILITY OBSERVATIONS TOTAL HOURS OF STABILITY CLASS C TOTAL TOTAL TOTAL HOURS HOURS HOURS OF VALID WIND DIRECTION-WIND SPEED-STABILITY CLASS C OF VALID WIND DIRECTION-WIND SPEED-STABILITY OBSERVATIONS CALM 2188 165 165 2187 0

METEOROLOGICAL FACILITY:

BROWNS FERRY NUCLEAR PLANT STABILITY BASED ON DELTA-T BETWEEN 10.03 AND 45.30 METERS WIND SPEED AND DIRECTION MEASURED AT 10.50 METER LEVEL DATE PRINTED: 2013/11/15 MEAN WIND SPEED =

4.55 NOTE:

TOTALS AND SUBTOTALS ARE OBTAINED FROM UNROUNDED NUMBERS E-68

BROWNS FERRY NUCLEAR PLANT UNITS 1, 2, AND 3 2013 ANNUAL RADIOACTIVE EFFLUENT RELEASE REPORT JOINT PERCENTAGE FREQUENCIES OF WIND SPEED BY WIND DIRECTION FOR STABILITY CLASS D

(-1.5< DELTA T<=-0.5 C/100 M)

BROWNS FERRY NUCLEAR PLANT JUL 1, 2013 -

SEP 30, 2013 WIND DIRECTION N

NNE NE ENE E

ESE SE SSE S

SSW SW WSW W

WNW NW NNW SUBTOTAL WIND SPEED(MPH) 0.6-1.4 1.5-3.4 3.5-5.4 5.5-7.4 7.5-12.4 12.5-18.4 CALM

0. 000
0. 000
0. 000
0. 000 0.000
0. 000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 18.5-24.4

>=24.5 TOTAL 0.000 0.000 0.000 0.000 0.046 0.000 0.183 0.091 0.137 0.091 0.137 0.000 0.000 0.000 0.000 0.000 0.091 0.320 0.457 0.412 1.097 1.738

1. 692 1.555 1.875 2.286 0.640 1.555 0.823 0.091 0.091 0.137 0.640 0.777 0.229 0.777 2.835 2.103 0.091 0.091 0.000 0.091 0.183 0.594 1.417 0.320 0.457 0.320 10.928 0.412 0.274 0.183 0.046 0.320 0.823 0.000 0.000 0.000 0.000 0.000 0.000 0.320 0.412 0.229 0.320 3.338 0.183 0.274 0.091 0.000 0.046 0.091 0.000 0.000 0.000 0.000 0.000 0.000 0.091 0.183 0.183 0.091 1.235 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.046 0.000 0.046 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 1.326 1.646 0.960 1.235 4.344 4.755 1.966 1.738 2.012 2.469 0.960 2.149 2.652 1.006 1.006 0.869 0.686 14.861 0.000 31.093 TOTAL HOURS OF VALID STABILITY OBSERVATIONS TOTAL HOURS OF STABILITY CLASS D TOTAL TOTAL TOTAL HOURS HOURS HOURS OF VALID WIND DIRECTION-WIND SPEED-STABILITY CLASS D OF VALID WIND DIRECTION-WIND SPEED-STABILITY OBSERVATIONS CALM 2188 680 680 2187 0

METEOROLOGICAL FACILITY:

BROWNS FERRY NUCLEAR PLANT STABILITY BASED ON DELTA-T BETWEEN 10.03 AND 45.30 METERS WIND SPEED AND DIRECTION MEASURED AT 10.50 METER LEVEL DATE PRINTED: 2013/11/15 MEAN WIND SPEED =

3.82 NOTE:

TOTALS AND SUBTOTALS ARE OBTAINED FROM UNROUNDED NUMBERS E-69

BROWNS FERRY NUCLEAR PLANT UNITS 1, 2, AND 3 2013 ANNUAL RADIOACTIVE EFFLUENT RELEASE REPORT JOINT PERCENTAGE FREQUENCIES OF WIND SPEED BY WIND DIRECTION FOR STABILITY CLASS E

(-0.5< DELTA T<= 1.5 C/100 M)

BROWNS FERRY NUCLEAR PLANT JUL 1, 2013 -

SEP 30, 2013 WIND DIRECTION N

NNE NE ENE E

ESE SE SSE S

SSW SW WSW W

WNW NW NNW SUBTOTAL WIND SPEED (MPH) 0.6-1.4 1.5-3.4 3.5-5.4 5.5-7.4 7.5-12.4 12.5-18.4 CALM 0.000 0.0 00 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 18.5-24.4

>=24.5 TOTAL 0.183 0.000 0.274 0.183 0.137 0.549 0.457 0.457 0.503 0.457 0.594 0.320 0.091 0.000 0.091 0.091 1.326 1.052 0.412 1.555 2.881 1.692 1.189 0.457 0.823 0.549 0.457 0.549 0.412 0.274 0.412 1.006 0.732 1.097 0.503 0.457 2.835 1.692 0.000 0.046 0.046 0.046 0.000 0.046 0.366 0.137 0.046 0.686 8.733 0.000 0.412 0.274 0.000 0.091 0.091 0.000 0.000 0.046 0.000 0.000 0.000 0.046 0.000 0.046 0.046 1.052 0.000 0.000 0.046 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.046 0.091 0.000 0.046 0.229 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.046 0.000 0.046 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 2.241 2.561 1.509 2.195 5.944 4.024 1.646 0.960 1.417 1.052 1.052 0.914 0.960 0.503 0.640 1.875 4.390 15.043 0.000 29.492 TOTAL HOURS OF VALID STABILITY OBSERVATIONS TOTAL HOURS OF STABILITY CLASS E 2188 645 645 2187 TOTAL TOTAL TOTAL HOURS HOURS HOURS OF VALID WIND DIRECTION-WIND SPEED-STABILITY CLASS E OF VALID WIND DIRECTION-WIND SPEED-STABILITY OBSERVATIONS CALM METEOROLOGICAL FACILITY:

BROWNS FERRY NUCLEAR PLANT STABILITY BASED ON DELTA-T BETWEEN 10.03 AND 45.30 METERS WIND SPEED AND DIRECTION MEASURED AT 10.50 METER LEVEL MEAN WIND SPEED =

2.94 NOTE:

TOTALS AND SUBTOTALS ARE OBTAINED FROM UNROUNDED NUMBERS DATE PRINTED: 2013/11/15 E-70

BROWNS FERRY NUCLEAR PLANT UNITS 1, 2, AND 3 2013 ANNUAL RADIOACTIVE EFFLUENT RELEASE REPORT JOINT PERCENTAGE FREQUENCIES OF WIND SPEED BY WIND DIRECTION FOR STABILITY CLASS F

( 1.5< DELTA T<= 4.0 C/100 M)

BROWNS FERRY NUCLEAR PLANT JUL 1, 2013 -

SEP 30, 2013 WIND DIRECTION N

NNE NE ENE E

ESE SE SSE S

SSW SW WSW W

WNW NW NNW SUBTOTAL WIND SPEED(MPH) 0.6-1.4 1.5-3.4 3.5-5.4 5.5-7.4 7.5-12.4 12.5-18.4 18.5-24.4 CALM 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000

>=24.5 TOTAL 0.320 0.137 0.183 0.137 0.137 0.091 0.274 0.091 0.000 0.320 0.046 0.000 0.091 0.274 0.000 0.137 2.241 1.875 1.006 0.412 1.463 1.646 0.320 0.320 0.046 0.000 0.000 0.000 0.137 0.183 0.046 0.183 0.457 8.093 0.732 0.594 0.183 0.549 0.366 0.046 0.000 0.000 0.000 0.000 0.000 0.000 0.046 0.000 0.000 0.046 2.561 0.000 0.183 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.183 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 2.926 1.920 0.777 2.149 2.149 0.457 0.594 0.137 0.000 0.320 0.046 0.137 0.320 0.320 0.183 0.640 0.000 13.077 TOTAL HOURS OF VALID STABILITY OBSERVATIONS TOTAL HOURS OF STABILITY CLASS F TOTAL TOTAL TOTAL HOURS HOURS HOURS OF VALID WIND DIRECTION-WIND SPEED-STABILITY CLASS F OF VALID WIND DIRECTION-WIND SPEED-STABILITY OBSERVATIONS CALM 2188 286 286 2187 0

METEOROLOGICAL FACILITY:

BROWNS FERRY NUCLEAR PLANT STABILITY BASED ON DELTA-T BETWEEN 10.03 AND 45.30 METERS WIND SPEED AND DIRECTION MEASURED AT 10.50 METER LEVEL MEAN WIND SPEED =

2.61 NOTE:

TOTALS AND SUBTOTALS ARE OBTAINED FROM UNROUNDED NUMBERS DATE PRINTED: 2013/11/15 E-71

BROWNS FERRY NUCLEAR PLANT UNITS 1, 2, AND 3 2013 ANNUAL RADIOACTIVE EFFLUENT RELEASE REPORT JOINT PERCENTAGE FREQUENCIES OF WIND SPEED BY WIND DIRECTION FOR STABILITY CLASS G (DELTA T > 4.0 C/100 M)

BROWNS FERRY NUCLEAR PLANT JUL 1, 2013 -

SEP 30, 2013 WIND DIRECTION N

NNE NE ENE E

ESE SE SSE S

SSW SW WSW W

WNW NW NNW SUBTOTAL WIND SPEED(MPH) 0.6-1.4 1.5-3.4 3.5-5.4 5.5-7.4 7.5-12.4 12.5-18.4 18.5-24.4 CALM 0.009 0.010 0.009 0.005 0.002 0.001 0.000 0.001 0.001 0.001 0.000 0.000 0.000 0.000 0.001 0.006 0.046

>=24.5 TOTAL 0.457 0.457 0.640 0.137 0.000 0.046 0.046 0.091 0.137 0.091 0.046 0.000 0.000 0.000 0.091 0.457 2.698 0.640 0.732 0.457 0.412 0.183 0.046 0.000 0.046 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.320 2.835 0.091 0.091 0.000 0.091 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.274 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 1.198 1.290 1.106 0.645 0.184 0.092 0.046 0.138 0.138 0.092 0.046 0.000 0.000 0.000 0.092 0.784 5.853 TOTAL HOURS OF VALID STABILITY OBSERVATIONS TOTAL HOURS OF STABILITY CLASS G TOTAL TOTAL TOTAL HOURS HOURS HOURS OF VALID WIND DIRECTION-WIND SPEED-STABILITY CLASS G OF VALID WIND DIRECTION-WIND SPEED-STABILITY OBSERVATIONS CALM 2188 128 128 2187 1

METEOROLOGICAL FACILITY:

BROWNS FERRY NUCLEAR PLANT STABILITY BASED ON DELTA-T BETWEEN 10.03 AND 45.30 METERS WIND SPEED AND DIRECTION MEASURED AT 10.50 METER LEVEL DATE PRINTED: 2013/11/15 MEAN WIND SPEED =

1.75 NOTE:

TOTALS AND SUBTOTALS ARE OBTAINED FROM UNROUNDED NUMBERS E-72

BROWNS FERRY NUCLEAR PLANT UNITS 1, 2, AND 3 2013 ANNUAL RADIOACTIVE EFFLUENT RELEASE REPORT BROWNS FERRY NUCLEAR PLANT 2013 METEOROLOGICAL DATA TABLE 7D JOINT FREQUENCY DISTRIBUTION IN PERCENT FOR GROUND LEVEL RELEASES FOURTH QUARTER E-73

BROWNS FERRY NUCLEAR PLANT UNITS 1, 2, AND 3 2013 ANNUAL RADIOACTIVE EFFLUENT RELEASE REPORT JOINT PERCENTAGE FREQUENCIES OF WIND SPEED BY WIND DIRECTION FOR STABILITY CLASS A (DELTA T<=-1.9 C/100 M)

BROWNS FERRY NUCLEAR PLANT OCT 1, 2013 -

DEC 31, 2013 WIND DIRECTION N

NNE NE ENE E

ESE SE SSE S

SSW SW WSW W

WNW NW NNW SUBTOTAL WIND SPEED (MPH) 0.6-1.4 1.5-3.4 3.5-5.4 5.5-7.4 CALM 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 7.5-12.4 12.5-18.4 18.5-24.4

>=24.5 TOTAL 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.408 0.998 0.681 0.091 0.000 0.000 0.000 0.000 0.000 0.000 2.178 0.000 0.000 0.000 0.000 0.000 0.136 0.318 0.454 0.181 0.091 0.045 0.000 0.000 0.000 0.000 0.000 1.225 0.000 0.091 0.045 0.000 0.000 0.045 0.227 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.408 0.045 0.272 0.091 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.136 0.000 0.544 0.181 0.000 0.045 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.227 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.227 0.363 0.181 0.000 0.000 0.181 0.953 1.452 0.862 0.181 0.045 0.000 0.000 0.000 0.136 0.000 4.583 TOTAL HOURS OF VALID STABILITY OBSERVATIONS TOTAL HOURS OF STABILITY CLASS A TOTAL TOTAL TOTAL HOURS HOURS HOURS OF VALID WIND DIRECTION-WIND SPEED-STABILITY CLASS A OF VALID WIND DIRECTION-WIND SPEED-STABILITY OBSERVATIONS CALM 2204 101 101 2204 0

METEOROLOGICAL FACILITY:

BROWNS FERRY NUCLEAR PLANT STABILITY BASED ON DELTA-T BETWEEN 10.03 AND 45.30 METERS WIND SPEED AND DIRECTION MEASURED AT 10.50 METER LEVEL DATE PRINTED: 2014/02/25 MEAN WIND SPEED =

4.86 NOTE:

TOTALS AND SUBTOTALS ARE OBTAINED FROM UNROUNDED NUMBERS E-74

BROWNS FERRY NUCLEAR PLANT UNITS 1, 2, AND 3 2013 ANNUAL RADIOACTIVE EFFLUENT RELEASE REPORT JOINT PERCENTAGE FREQUENCIES OF WIND SPEED BY WIND DIRECTION FOR STABILITY CLASS B

(-1.9< DELTA T<=-1.7 C/100 M)

BROWNS FERRY NUCLEAR PLANT OCT 1, 2013 -

DEC 31, 2013 WIND DIRECTION N

NNE NE ENE E

ESE SE SSE S

SSW SW WSW W

WNW NW NNW SUBTOTAL WIND SPEED(MPH) 0.6-1.4 1.5-3.4 3.5-5.4 5.5-7.4 CALM 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 7.5-12.4 12.5-18.4 18.5-24.4

>=24.5 TOTAL 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.091 0.227 0.318 0.091 0.091 0.000 0.000 0.000 0.000 0.000 0.000 0.817 0.000 0.000 0.000 0.045 0.045 0.045 0.181 0.000 0.000 0.045 0.000 0.000 0.000 0.000 0.000 0.000 0.363 0.045 0.181 0.181 0.045 0.000 0.000 0.045 0.000 0.000 0.000 0.000 0.000 0.045 0.000 0.000 0.000 0.544 0.318 0.181 0.045 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.091 0.045 0.227 0.907 0.045 0.000 0.045 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.091 0.136 0.000 0.318 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.408 0.363 0.272 0.091 0.045 0.136 0.454 0.318 0.091 0.136 0.000 0.000 0.045 0.181 0.181 0.227 2.949 TOTAL HOURS OF VALID STABILITY OBSERVATIONS TOTAL HOURS OF STABILITY CLASS B TOTAL TOTAL TOTAL HOURS HOURS HOURS OF VALID WIND DIRECTION-WIND SPEED-STABILITY CLASS B OF VALID WIND DIRECTION-WIND SPEED-STABILITY OBSERVATIONS CALM 2204 65 65 2204 0

METEOROLOGICAL FACILITY:

BROWNS FERRY NUCLEAR PLANT STABILITY BASED ON DELTA-T BETWEEN 10.03 AND 45.30 METERS WIND SPEED AND DIRECTION MEASURED AT 10.50 METER LEVEL DATE PRINTED: 2014/02/25 MEAN WIND SPEED =

6.80 NOTE:

TOTALS AND SUBTOTALS ARE OBTAINED FROM UNROUNDED NUMBERS E-75

BROWNS FERRY NUCLEAR PLANT UNITS 1, 2, AND 3 2013 ANNUAL RADIOACTIVE EFFLUENT RELEASE REPORT JOINT PERCENTAGE FREQUENCIES OF WIND SPEED BY WIND DIRECTION FOR STABILITY CLASS C

(-1.7< DELTA T<=-1.5 C/100 M)

BROWNS FERRY NUCLEAR PLANT OCT 1, 2013 -

DEC 31, 2013 WIND DIRECTION N

NNE NE ENE E

ESE SE SSE S

SSW SW WSW W

WNW NW NNW SUBTOTAL WIND SPEED(MPH) 0.6-1.4 1.5-3.4 3.5-5.4 5.5-7.4 7.5-12.4 12.5-18.4 CALM 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 18.5-24.4

>=24.5 TOTAL 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.045 0.227 0.454 0.272 0.091 0.136 0.000 0.000 0.000 0.000 0.000 1.225 0.045 0.136 0.091 0.091 0.045 0.136 0.136 0.045 0.091 0.000 0.136 0.181 0.091 0.000 0.045 0.000 1.270 0.045 0.181 0.045 0.000 0.000 0.227 0.000 0.000 0.000 0.000 0.000 0.045 0.091 0.000 0.000 0.000 0.635 0.363 0.136 0.091 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.136 0.318 0.272 1.316 0.045 0.045 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.091 0.000 0.181 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.499 0.499 0.227 0.091 0.045 0.408 0.363 0.499 0.363 0.091 0.272 0.227 0.181 0.136 0.454 0.272 4.628 TOTAL HOURS OF VALID STABILITY OBSERVATIONS TOTAL HOURS OF STABILITY CLASS C TOTAL TOTAL TOTAL HOURS HOURS HOURS OF VALID WIND DIRECTION-WIND SPEED-STABILITY CLASS C OF VALID WIND DIRECTION-WIND SPEED-STABILITY OBSERVATIONS CALM 2204 102 102 2204 0

METEOROLOGICAL FACILITY:

BROWNS FERRY NUCLEAR PLANT STABILITY BASED ON DELTA-T BETWEEN 10.03 AND 45.30 METERS WIND SPEED AND DIRECTION MEASURED AT 10.50 METER LEVEL DATE PRINTED: 2014/02/25 MEAN WIND SPEED =

6.04 NOTE:

TOTALS AND SUBTOTALS ARE OBTAINED FROM UNROUNDED NUMBERS E-76

BROWNS FERRY NUCLEAR PLANT UNITS 1, 2, AND 3 2013 ANNUAL RADIOACTIVE EFFLUENT RELEASE REPORT JOINT PERCENTAGE FREQUENCIES OF WIND SPEED BY WIND DIRECTION FOR STABILITY CLASS D

(-1.5< DELTA T<=-0.5 C/100 M)

BROWNS FERRY NUCLEAR PLANT OCT 1, 2013 -

DEC 31, 2013 WIND DIRECTION N

NNE NE ENE E

ESE SE SSE S

SSW SW WSW W

WNW NW NNW SUBTOTAL WIND SPEED(MPH) 0.6-1.4 1.5-3.4 3.5-5.4 5.5-7.4 7.5-12.4 12.5-18.4 18.5-24.4 CALM 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000

>=24.5 TOTAL 0.000 0.045 0.000 0.000 0.000 0.000 0.045 0.000 0.000 0.000 0.091 0.000 0.000 0.000 0.000 0.000 0.181 0.227 0.272 0.227 0.454 0.363 0.998 1.316 1.044 1.180 1.452 0.590 0.454 0.181 0.227 0.045 0.272 9.301 0.681 0.681 0.272 0.091 0.635 1.180 0.363 0.181 0.181 0.045 0.181 0.318 1.044 0.408 0.408 0.635 7.305 0.998 0.907 0.499 0.227 0.136 0.499 0.045 0.000 0.045 0.091 0.000 0.000 0.408 0.590 0.544 0.907 5.898 1.951 0.998 0.136 0.000 0.000 0.045 0.000 0.000 0.000 0.000 0.000 0.000 0.091 0.771 1.679 1.906 7.577 0.136 0.045 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.045 0.817 0.499 1.543 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 3.993 2.949 1.134 0.771 1.134 2.722 1.770 1.225 1.407 1.588 0.862 0.771 1.724 2.042 3.494 4.220 0.000 31.806 TOTAL HOURS OF VALID STABILITY OBSERVATIONS TOTAL HOURS OF STABILITY CLASS D TOTAL TOTAL TOTAL HOURS HOURS HOURS OF VALID WIND DIRECTION-WIND SPEED-STABILITY CLASS D OF VALID WIND DIRECTION-WIND SPEED-STABILITY OBSERVATIONS CALM 2204 701 701 2204 0

METEOROLOGICAL FACILITY:

BROWNS FERRY NUCLEAR PLANT STABILITY BASED ON DELTA-T BETWEEN 10.03 AND 45.30 METERS WIND SPEED AND DIRECTION MEASURED AT 10.50 METER LEVEL DATE PRINTED: 2014/02/25 MEAN WIND SPEED =

5.84 NOTE:

TOTALS AND SUBTOTALS ARE OBTAINED FROM UNROUNDED NUMBERS E-77

BROWNS FERRY NUCLEAR PLANT UNITS 1, 2, AND 3 2013 ANNUAL RADIOACTIVE EFFLUENT RELEASE REPORT JOINT PERCENTAGE FREQUENCIES OF WIND SPEED BY WIND DIRECTION FOR STABILITY CLASS E

(-0.5< DELTA T<= 1.5 C/100 M)

BROWNS FERRY NUCLEAR PLANT OCT 1, 2013 -

DEC 31, 2013 WIND DIRECTION WIND SPEED(MPH) 0.6-1.4 1.5-3.4 3.5-5.4 5.5-7.4 N

NNE NE ENE E

ESE SE SSE S

SSW SW WSW W

WNW NW NNW CALM 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 7.5-12.4 12.5-18.4 18.5-24.4 0.000 0.091 0.136 0.136 0.091 0.181 0.227 0.454 0.227 0.091 0.181 0.000 0.045 0.045 0.091 0.045 0.681 0.363 0.181 0.272 1.316 1.588 1.633 1.497 1.543 0.635 0.408 0.363 0.499 0.318 0.136 0.181 0.499 0.726 0.181 0.318 0.544 1.633 0.635 0.000 0.272 0.091 0.000 0.136 0.590 0.136 0.363 0.726 6.851

>=24.5 TOTAL 0.499 0.363 0.726 0.091 0.045 0.408 0.045 0.000 0.227 0.091 0.000 0.045 0.227 0.000 0.181 0.817 3.766 0.363 0.045 0.045 0.000 0.000 0.000 0.000 0.000 0.045 0.091 0.045 0.045 0.000 0.136 0.227 0.181 1.225 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.045 0.045 0.091 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 2.042 1.588 1.270 0.817 1.996 3.811 2.541 1.951 2.314 0.998 0.635 0.590 1.361 0.635 1.044 1.996 SUBTOTAL 2.042 11.615 0.000 25.590 TOTAL HOURS OF VALID STABILITY OBSERVATIONS TOTAL HOURS OF STABILITY CLASS E TOTAL TOTAL TOTAL HOURS HOURS HOURS OF VALID WIND DIRECTION-WIND SPEED-STABILITY CLASS E OF VALID WIND DIRECTION-WIND SPEED-STABILITY OBSERVATIONS CALM 2204 564 564 2204 0

METEOROLOGICAL FACILITY:

BROWNS FERRY NUCLEAR PLANT STABILITY BASED ON DELTA-T BETWEEN 10.03 AND 45.30 METERS WIND SPEED AND DIRECTION MEASURED AT 10.50 METER LEVEL DATE PRINTED: 2014/02/25 MEAN WIND SPEED =

3.71 NOTE:

TOTALS AND SUBTOTALS ARE OBTAINED FROM UNROUNDED NUMBERS E-78

BROWNS FERRY NUCLEAR PLANT UNITS 1, 2, AND 3 2013 ANNUAL RADIOACTIVE EFFLUENT RELEASE REPORT JOINT PERCENTAGE FREQUENCIES OF WIND SPEED BY WIND DIRECTION FOR STABILITY CLASS F

( 1.5< DELTA T<= 4.0 C/100 M)

BROWNS FERRY NUCLEAR PLANT OCT 2, 2013 -

DEC 31, 2013 WIND DIRECTION N

NNE NE ENE E

ESE SE SSE S

SSW SW WSW W

WNW NW NNW SUBTOTAL WIND SPEED(MPH) 0.6-1.4 1.5-3.4 3.5-5.4 5.5-7.4 7.5-12.4 12.5-18.4 18.5-24.4 CALM 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000

>=24.5 TOTAL 0.045 0.272 0.091 0.181 0.408 0.136 0.318 0.272 0.408 0.045 0.045 0.000 0.000 0.045 0.136 0.181 1.316 0.681 0.544 1.361 1.770 0.817 0.862 0.771 1.270 0.091 0.000 0.000 0.000 0.000 0.091 0.726 0.771 0.318 0.136 0.318 0.363 0.181 0.091 0.091 0.544 0.045 0.000 0.000 0.000 0.000 0.000 0.590 3.448 0.227 0.091 0.000 0.000 0.000 0.000 0.000 0.000 0.227 0.000 0.000 0.000 0.000 0.000 0.000 0.227 0.771 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.045 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.045 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 2.359 1.361 0.771 1.860 2.541 1.134 1.270 1.134 2.495 0.181 0.045 0.000 0.000 0.045 0.227 1.724 2.586 10.299 0.000 17.151 TOTAL HOURS OF VALID STABILITY OBSERVATIONS TOTAL HOURS OF STABILITY CLASS F TOTAL TOTAL TOTAL HOURS HOURS HOURS OF VALID WIND DIRECTION-WIND SPEED-STABILITY CLASS F OF VALID WIND DIRECTION-WIND SPEED-STABILITY OBSERVATIONS CALM 2204 378 378 2204 0

METEOROLOGICAL FACILITY:

BROWNS FERRY NUCLEAR PLANT STABILITY BASED ON DELTA-T BETWEEN 10.03 AND 45.30 METERS WIND SPEED AND DIRECTION MEASURED AT 10.50 METER LEVEL MEAN WIND SPEED =

2.76 NOTE:

TOTALS AND SUBTOTALS ARE OBTAINED FROM UNROUNDED NUMBERS DATE PRINTED: 2014/02/25 E-79

BROWNS FERRY NUCLEAR PLANT UNITS 1, 2, AND 3 2013 ANNUAL RADIOACTIVE EFFLUENT RELEASE REPORT JOINT PERCENTAGE FREQUENCIES OF WIND SPEED BY WIND DIRECTION FOR STABILITY CLASS G (DELTA T > 4.0 C/100 M)

BROWNS FERRY NUCLEAR PLANT OCT 1, 2013 -

DEC 31, 2013 WIND DIRECTION N

NNE NE ENE E

ESE SE SSE S

SSW SW WSW W

WNW NW NNW SUBTOTAL WIND SPEED(MPH) 0.6-1.4 1.5-3.4 3.5-5.4 5.5-7.4 7.5-12.4 12.5-18.4 CALM 0.011 0.007 0.005 0.003 0.002 0.001 0.001 0.007 0.002 0.000 0.000 0.000 0.000 0.000 0.001 0.005 0.045 18.5-24.4

>=24.5 TOTAL 1.407 0.681 0.454 0.181 0.136 0.136 0.136 0.454 0.091 0.045 0.000 0.045 0.045 0.000 0.272 0.862 4.946 1.497 1.134 0.953 0.681 0.363 0.045 0.091 1.270 0.499 0.000 0.000 0.000 0.000 0.000 0.091 0.408 7.033 0.363 0.091 0.000 0.181 0.045 0.000 0.000 0.045 0.272 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.998 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.136 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.136 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.136 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.136 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 3.278 1.913 1.412 1.047 0.546 0.182 0.228 1.776 1.137 0.046 0.000 0.046 0.046 0.000 0.364 1.275 0.000 13.294 TOTAL HOURS OF VALID STABILITY OBSERVATIONS TOTAL HOURS OF STABILITY CLASS G 2204 293 293 2204 TOTAL TOTAL TOTAL HOURS HOURS HOURS OF VALID WIND DIRECTION-WIND SPEED-STABILITY CLASS G OF VALID WIND DIRECTION-WIND SPEED-STABILITY OBSERVATIONS CALM METEOROLOGICAL FACILITY:

BROWNS FERRY NUCLEAR PLANT STABILITY BASED ON DELTA-T BETWEEN 10.03 AND 45.30 METERS WIND SPEED AND DIRECTION MEASURED AT 10.50 METER LEVEL DATE PRINTED: 2014/02/25 MEAN WIND SPEED =

2.00 NOTE:

TOTALS AND SUBTOTALS ARE OBTAINED FROM UNROUNDED NUMBERS E-80

BROWNS FERRY NUCLEAR PLANT UNITS 1, 2, AND 3 2013 ANNUAL RADIOACTIVE EFFLUENT RELEASE REPORT BROWNS FERRY NUCLEAR PLANT 2013 METEOROLOGICAL DATA TABLE 8A JOINT FREQUENCY DISTRIBUTION IN PERCENT FOR SPLIT LEVEL RELEASES (GROUND LEVEL RELEASE MODE AND ELEVATED RELEASE MODE)

FIRST QUARTER E-81

BROWNS FERRY NUCLEAR PLANT UNITS 1, 2, AND 3 2013 ANNUAL RADIOACTIVE EFFLUENT RELEASE REPORT SPLIT JOINT PERCENTAGE FREQUENCIES OF WIND SPEED BY WIND DIRECTION FOR STABILITY CLASS A (DELTA T<=-1.9 C/100 M)

BROWNS FERRY NUCLEAR PLANT PART 1 OF 2 GROUND LEVEL RELEASE MODE JAN 1, 2013 -

MAR 31, 2013 WIND DIRECTION N

NNE NE ENE E

ESE SE SSE S

SSW SW WSW W

WNW NW NNW SUBTOTAL WIND SPEED(MPH) 0.6-1.4 1.5-3.4 3.5-5.4 5.5-7.4 CALM 7.5-12.4 12.5-18.4 18.5-24.4 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.001 0.007 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.008 0.000 0.000 0.000 0.000 0.005 0.000 0.088 0.019 0.034 0.017 0.010 0.009 0.000 0.000 0.000 0.000 0.183 0.000 0.000 0.000 0.005 0.000 0.008 0.018 0.000 0.041 0.008 0.000 0.000 0.000 0.000 0.000 0.000 0.080 0.049 0.033 0.000 0.000 0.000 0.008 0.000 0.000 0.072 0.000 0.009 0.008 0.000 0.039 0.008 0.021 0.248 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.063 0.067 0.019 0.149 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000

>=24. 5 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 TOTAL 0.049 0.033 0.000 0.005 0.005 0.017 0.106 0.021 0.154 0.025 0.019 0.018 0.000 0.101 0.076 0.039 0.667 TOTAL TOTAL TOTAL TOTAL HOURS HOURS HOURS HOURS OF VALID OBSERVATIONS OF GROUND LEVEL RELEASE OF STABILITY CLASS A OF GROUND LEVEL STABILITY CLASS A 2141.000 327.230 16.110 14.290 METEOROLOGICAL FACILITY:

BROWNS FERRY NUCLEAR PLANT STABILITY BASED ON DELTA-T BETWEEN 10.03 AND 45.30 METERS WIND DIRECTION MEASURED AT 10.50 METER LEVEL WIND SPEED MEASURED AT 10.50 METER LEVEL EFFLUENT VELOCITY = 12.60 M/S NOTE:

TOTALS AND SUBTOTALS ARE OBTAINED FROM UNROUNDED NUMBERS DATE PRINTED: 2013/05/22 E-82

BROWNS FERRY NUCLEAR PLANT UNITS 1, 2, AND 3 2013 ANNUAL RADIOACTIVE EFFLUENT RELEASE REPORT SPLIT JOINT PERCENTAGE FREQUENCIES OF WIND SPEED BY WIND DIRECTION FOR STABILITY CLASS B

(-1.9< DELTA T<=-1.7 C/100 M)

BROWNS FERRY NUCLEAR PLANT PART 1 OF 2 GROUND LEVEL RELEASE MODE JAN 1, 2013 -

MAR 31, 2013 WIND DIRECTION N

NNE NE ENE E

ESE SE SSE S

SSW SW WSW W

WNW NW NNW SUBTOTAL WIND SPEED (MPH) 0.6-1.4 1.5-3.4 3.5-5.4 5.5-7.4 CALM 7.5-12.4 12.5-18.4 18.5-24.4

>=24.5 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.006 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.007 0.000 0.000 0.000 0.000 0.001 0.000 0.006 0.000 0.000 0.007 0.000 0.006 0.000 0.000 0.000 0.000 0.020 0.009 0.031 0.004 0.005 0.000 0.000 0.000 0.000 0.000 0.000 0.009 0.005 0.000 0.003 0.000 0.002 0.068 0.000 0.000 0.000 0.000 0.000 0.008 0.000 0.000 0.000 0.000 0.000 0.008 0.005 0.105 0.058 0.022 0.207 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.045 0.018 0.009 0.073 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 TOTAL 0.009 0.031 0.004 0.005 0.001 0.008 0.007 0.006 0.000 0.007 0.009 0.019 0.005 0.154 0.077 0.034 0.375 TOTAL TOTAL TOTAL TOTAL HOURS HOURS HOURS HOURS OF VALID OBSERVATIONS OF GROUND LEVEL RELEASE OF STABILITY CLASS B OF GROUND LEVEL STABILITY CLASS B 2141.000 327.230 26.010 8.020 METEOROLOGICAL FACILITY:

BROWNS FERRY NUCLEAR PLANT STABILITY BASED ON DELTA-T BETWEEN 10.03 AND 45.30 METERS WIND DIRECTION MEASURED AT 10.50 METER LEVEL WIND SPEED MEASURED AT 10.50 METER LEVEL EFFLUENT VELOCITY = 12.60 M/S NOTE:

TOTALS AND SUBTOTALS ARE OBTAINED FROM UNROUNDED NUMBERS DATE PRINTED: 2013/05/22 E-83

BROWNS FERRY NUCLEAR PLANT UNITS 1, 2, AND 3 2013 ANNUAL RADIOACTIVE EFFLUENT RELEASE REPORT SPLIT JOINT PERCENTAGE FREQUENCIES OF WIND SPEED BY WIND DIRECTION FOR STABILITY CLASS C

(-1.7< DELTA T<=-1.5 C/100 M)

BROWNS FERRY NUCLEAR PLANT PART 1 OF 2 GROUND LEVEL RELEASE MODE JAN 1, 2013 -

MAR 31, 2013 WIND DIRECTION N

NNE NE ENE E

ESE SE SSE S

SSW SW WSW W

WNW NW NNW SUBTOTAL WIND SPEED(MPH) 0.6-1.4 1.5-3.4 3.5-5.4 5.5-7.4 CALM 7.5-12.4 12.5-18.4 18.5-24.4 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.004 0.007 0.000 0.001 0.000 0.000 0.000 0.000 0.000 0.000 0.012 0.000 0.000 0.000 0.000 0.000 0.006 0.012 0.000 0.002 0.007 0.003 0.000 0.000 0.000 0.000 0.000 0.031 0.000 0.001 0.000 0.000 0.003 0.007 0.000 0.000 0.000 0.000 0.009 0.023 0.011 0.009 0.003 0.009 0.075 0.018 0.029 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.008 0.021 0.063 0.078 0.031 0.249 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.039 0.062 0.075 0.010 0.185 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.030 0.000 0.000 0.030

>=24. 5 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 TOTAL 0.018 0.031 0.000 0.000 0.003 0.013 0.016 0.007 0.002 0.008 0.013 0.032 0.071 0.164 0.157 0.050 0.583 TOTAL HOURS OF VALID OBSERVATIONS TOTAL HOURS OF GROUND LEVEL RELEASE TOTAL HOURS OF STABILITY CLASS C TOTAL HOURS OF GROUND LEVEL STABILITY CLASS C 2141.000 327.230 70.070 12.480 METEOROLOGICAL FACILITY:

BROWNS FERRY NUCLEAR PLANT STABILITY BASED ON DELTA-T BETWEEN 10.03 AND 45.30 METERS WIND DIRECTION MEASURED AT 10.50 METER LEVEL WIND SPEED MEASURED AT 10.50 METER LEVEL EFFLUENT VELOCITY = 12.60 M/S NOTE:

TOTALS AND SUBTOTALS ARE OBTAINED FROM UNROUNDED NUMBERS DATE PRINTED: 2013/05/22 E-84

BROWNS FERRY NUCLEAR PLANT UNITS 1, 2, AND 3 2013 ANNUAL RADIOACTIVE EFFLUENT RELEASE REPORT SPLIT JOINT PERCENTAGE FREQUENCIES OF WIND SPEED BY WIND DIRECTION FOR STABILITY CLASS D

(-1.5< DELTA T<=-0.5 C/100 M)

BROWNS FERRY NUCLEAR PLANT PART 1 OF 2 GROUND LEVEL RELEASE MODE JAN 1, 2013 -

MAR 31, 2013 WIND DIRECTION N

NNE NE ENE E

ESE SE SSE S

SSW SW WSW W

WNW NW NNW SUBTOTAL WIND SPEED(MPH) 0.6-1.4 1.5-3.4 3.5-5.4 5.5-7.4 CALM 7.5-12.4 12.5-18.4 18.5-24.4 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.001 0.008 0.009 0.012 0.054 0.028 0.009 0.007 0.002 0.000 0.000 0.000 0.000 0.129 0.051 0.046 0.042 0.026 0.056 0.092 0.149 0.008 0.010 0.020 0.008 0.058 0.020 0.001 0.017 0.020 0.623 0.158 0.052 0.039 0.037 0.024 0.078 0.076 0.000 0.051 0.026 0.059 0.097 0.096 0.040 0.072 0.134 1.039 0.160 0.060 0.019 0.000 0.000 0.174 0.111 0.000 0.000 0.000 0.010 0.036 0.079 0.210 0.495 0.173 1.526 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.090 0.332 0.586 0.188 1.196 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.045 0.534 0.234 0.000 0.813

>=24.5 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.047 0.000 0.047 TOTAL 0.369 0.158 0.099 0.064 0.088 0.353 0.348 0.062 0.089 0.054 0.084 0.192 0.330 1.117 1.450 0.514 5.372 TOTAL TOTAL TOTAL TOTAL HOURS HOURS HOURS HOURS OF OF OF OF VALID OBSERVATIONS GROUND LEVEL RELEASE STABILITY CLASS D GROUND LEVEL STABILITY CLASS D 2141.000 327.230 983.600 115.010 METEOROLOGICAL FACILITY:

BROWNS FERRY NUCLEAR PLANT STABILITY BASED ON DELTA-T BETWEEN 10.03 AND 45.30 METERS WIND DIRECTION MEASURED AT 10.50 METER LEVEL WIND SPEED MEASURED AT 10.50 METER LEVEL EFFLUENT VELOCITY = 12.60 M/S NOTE:

TOTALS AND SUBTOTALS ARE OBTAINED FROM UNROUNDED NUMBERS DATE PRINTED: 2013/05/22 E-85

BROWNS FERRY NUCLEAR PLANT UNITS 1, 2, AND 3 2013 ANNUAL RADIOACTIVE EFFLUENT RELEASE REPORT SPLIT JOINT PERCENTAGE FREQUENCIES OF WIND SPEED BY WIND DIRECTION FOR STABILITY CLASS E

(-0.5< DELTA T<= 1.5 C/100 M)

BROWNS FERRY NUCLEAR PLANT PART 1 OF 2 GROUND LEVEL RELEASE MODE JAN 1, 2013 -

MAR 31, 2013 WIND DIRECTION N

NNE NE ENE E

ESE SE SSE S

SSW SW WSW W

WNW NW NNW SUBTOTAL WIND SPEED(MPH) 0.6-1.4 1.5-3.4 3.5-5.4 5.5-7.4 CALM 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 7.5-12.4 12.5-18.4 18.5-24.4 0.000 0.000 0.000 0.000 0.000 0.002 0.000 0.003 0.000 0.004 0.000 0.000 0.000 0.000 0.000 0.000 0.009 0.057 0.028 0.007 0.008 0.021 0.041 0.076 0.152 0.163 0.057 0.014 0.029 0.001 0.002 0.004 0.013 0.672 0.099 0.126 0.071 0.043 0.050 0.171 0.306 0.200 0.157 0.036 0.033 0.023 0.020 0.009 0.020 0.141 1.505 0.113 0.026 0.048 0.000 0.015 0.050 0.292 0.047 0.269 0.009 0.008 0.018 0.033 0.015 0.089 0.106 1.138 0.024 0.025 0.040 0.008 0.000 0.000 0.021 0.000 0.262 0.141 0.047 0.000 0.008 0.030 0.081 0.152 0.839 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.053 0.069 0.025 0.000 0.148 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.086 0.000 0.000 0.086

>=24.5 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 TOTAL 0.292 0.205 0.165 0.059 0.087 0.265 0.696 0.401 0.851 0.247 0.102 0.070 0.115 0.211 0.219 0.411 4.397 TOTAL TOTAL TOTAL TOTAL HOURS HOURS HOURS HOURS OF VALID OBSERVATIONS OF GROUND LEVEL RELEASE OF STABILITY CLASS E OF GROUND LEVEL STABILITY CLASS E 2141.000 327.230 750.570 94.130 METEOROLOGICAL FACILITY:

BROWNS FERRY NUCLEAR PLANT STABILITY BASED ON DELTA-T BETWEEN 10.03 AND 45.30 METERS WIND DIRECTION MEASURED AT 10.50 METER LEVEL WIND SPEED MEASURED AT 10.50 METER LEVEL EFFLUENT VELOCITY = 12.60 M/S NOTE:

TOTALS AND SUBTOTALS ARE OBTAINED FROM UNROUNDED NUMBERS DATE PRINTED: 2013/05/22 E-86

BROWNS FERRY NUCLEAR PLANT UNITS 1, 2, AND 3 2013 ANNUAL RADIOACTIVE EFFLUENT RELEASE REPORT SPLIT JOINT PERCENTAGE FREQUENCIES OF WIND SPEED BY WIND DIRECTION FOR STABILITY CLASS F

( 1.5< DELTA T<= 4.0 C/100 M)

BROWNS FERRY NUCLEAR PLANT PART 1 OF 2 GROUND LEVEL RELEASE MODE JAN 1, 2013 -

MAR 31, 2013 WIND DIRECTION N

NNE NE ENE E

ESE SE SSE S

SSW SW WSW W

WNW NW NNW SUBTOTAL WIND SPEED(MPH) 0.6-1.4 1.5-3.4 3.5-5.4 5.5-7.4 CALM 7.5-12.4 12.5-18.4 18.5-24.4 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.007 0.000 0.000 0.015 0.006 0.007 0.000 0.000 0.000 0.000 0.004 0.000 0.038 0.058 0.004 0.021 0.002 0.029 0.065 0.111 0.149 0.143 0.052 0.014 0.000 0.005 0.000 0.003 0.018 0.675 0.065 0.017 0.013 0.000 0.005 0.015 0.070 0.056 0.408 0.033 0.024 0.000 0.000 0.000 0.007 0.049 0.761 0.000 0.000 0.000 0.000 0.000 0.000 0.028 0.000 0.273 0.019 0.000 0.000 0.000 0.000 0.000 0.030 0.351 0.000 0.000 0.000 0.000 0.000 0.000 0.086 0.000 0.304 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.390 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.047 0.000 0.000 0.047

>=24. 5 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 TOTAL 0.123 0.021 0.034 0.002 0.041 0.080 0.296 0.220 1.135 0.111 0.039 0.000 0.005 0.047 0.014 0.097 2.263 TOTAL TOTAL TOTAL TOTAL HOURS HOURS HOURS HOURS OF VALID OBSERVATIONS OF GROUND LEVEL RELEASE OF STABILITY CLASS F OF GROUND LEVEL STABILITY CLASS F 2141.000 327.230 232.500 48.450 METEOROLOGICAL FACILITY:

BROWNS FERRY NUCLEAR PLANT STABILITY BASED ON DELTA-T BETWEEN 10.03 AND 45.30 METERS WIND DIRECTION MEASURED AT 10.50 METER LEVEL WIND SPEED MEASURED AT 10.50 METER LEVEL EFFLUENT VELOCITY = 12.60 M/S NOTE:

TOTALS AND SUBTOTALS ARE OBTAINED FROM UNROUNDED NUMBERS DATE PRINTED: 2013/05/22 E-87

BROWNS FERRY NUCLEAR PLANT UNITS 1, 2, AND 3 2013 ANNUAL RADIOACTIVE EFFLUENT RELEASE REPORT SPLIT JOINT PERCENTAGE FREQUENCIES OF WIND SPEED BY WIND DIRECTION FOR STABILITY CLASS G (DELTA T > 4.0 C/100 M)

BROWNS FERRY NUCLEAR PLANT PART 1 OF 2 GROUND LEVEL RELEASE MODE JAN 1, 2013 -

MAR 31, 2013 WIND DIRECTION N

NNE NE ENE E

ESE SE SSE S

SSW SW WSW W

WNW NW NNW SUBTOTAL WIND SPEED(MPH) 0.6-1.4 1.5-3.4 3.5-5.4 5.5-7.4 CALM 7.5-12.4 12.5-18.4 18.5-24.4 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.002 0.000 0.000 0.019 0.034 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.056 0.035 0.000 0.000 0.014 0.009 0.000 0.116 0.240 0.316 0.016 0.000 0.000 0.000 0.000 0.000 0.006 0.753 0.000 0.005 0.000 0.000 0.000 0.000 0.000 0.100 0.295 0.000 0.000 0.000 0.000 0.000 0.000 0.004 0.405 0.000 0.000 0.000 0.000 0.000 0.000 0.039 0.000 0.350 0.000 0.025 0.000 0.000 0.000 0.000 0.000 0.414 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000

>=24. 5 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 TOTAL 0.035 0.005 0.000 0.017 0.009 0.000 0.174 0.375 0.961 0.016 0.025 0.000 0.000 0.000 0.000 0.010 1.628 TOTAL HOURS OF VALID OBSERVATIONS TOTAL TOTAL TOTAL HOURS HOURS HOURS OF GROUND LEVEL RELEASE OF STABILITY CLASS G OF GROUND LEVEL STABILITY CLASS G 2141.000 327.230 62.140 34.850 METEOROLOGICAL FACILITY:

BROWNS FERRY NUCLEAR PLANT STABILITY BASED ON DELTA-T BETWEEN 10.03 AND 45.30 METERS WIND DIRECTION MEASURED AT 10.50 METER LEVEL WIND SPEED MEASURED AT 10.50 METER LEVEL EFFLUENT VELOCITY = 12.60 M/S NOTE:

TOTALS AND SUBTOTALS ARE OBTAINED FROM UNROUNDED NUMBERS DATE PRINTED: 2013/05/22 E-88

BROWNS FERRY NUCLEAR PLANT UNITS 1, 2, AND 3 2013 ANNUAL RADIOACTIVE EFFLUENT RELEASE REPORT SPLIT JOINT PERCENTAGE FREQUENCIES OF WIND SPEED BY WIND DIRECTION FOR STABILITY CLASS A (DELTA T<=-1.9 C/100 M)

BROWNS FERRY NUCLEAR PLANT PART 2 OF 2 ELEVATED RELEASE MODE JAN 1, 2013 -

MAR 31, 2013 WIND DIRECTION N

NNE NE ENE E

ESE SE SSE S

SSW SW WSW W

WNW NW NNW SUBTOTAL WIND SPEED(MPH) 0.6-1.4 1.5-3.4 3.5-5.4 5.5-7.4 CALM 7.5-12.4 12.5-18.4 18.5-24.4 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.047 0.000 0.000 0.000 0.000 0.000 0.000 0.047 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.038 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.038 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000

>=24.5 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 TOTAL 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.038 0.000 0.047 0.000 0.000 0.000 0.000 0.000 0.000 0.085 TOTAL TOTAL TOTAL TOTAL HOURS HOURS HOURS HOURS OF VALID OBSERVATIONS OF ELEVATED RELEASES OF STABILITY CLASS A OF ELEVATED STABILITY CLASS A 2141.000 1813.770 16.110 1.820 METEOROLOGICAL FACILITY:

BROWNS FERRY NUCLEAR PLANT STABILITY BASED ON DELTA-T BETWEEN 10.03 AND 89.59 METERS WIND DIRECTION MEASURED AT 45.74 METER LEVEL WIND SPEED MEASURED AT 45.74 METER LEVEL EFFLUENT VELOCITY = 12.60 M/S NOTE:

TOTALS AND SUBTOTALS ARE OBTAINED FROM UNROUNDED NUMBERS DATE PRINTED: 2013/05/22 E-89

BROWNS FERRY NUCLEAR PLANT UNITS 1, 2, AND 3 2013 ANNUAL RADIOACTIVE EFFLUENT RELEASE REPORT SPLIT JOINT PERCENTAGE FREQUENCIES OF WIND SPEED BY WIND DIRECTION FOR STABILITY CLASS B

(-1.9< DELTA T<=-1.7 C/100 M)

BROWNS FERRY NUCLEAR PLANT PART 2 OF 2 ELEVATED RELEASE MODE JAN 1, 2013 -

MAR 31, 2013 WIND DIRECTION N

NNE NE ENE E

ESE SE SSE S

SSW SW WSW W

WNW NW NNW SUBTOTAL WIND SPEED(MPH) 0.6-1.4 1.5-3.4 3.5-5.4 5.5-7.4 CALM 7.5-12.4 12.5-18.4 18.5-24.4 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.093 0.047 0.047 0.047 0.000 0.000 0.000 0.000 0.000 0.234 0.000 0.000 0.000 0.000 0.000 0.045 0.043 0.047 0.000 0.000 0.000 0.043 0.000 0.000 0.000 0.000 0.178 0.000 0.040 0.000 0.000 0.000 0.000 0.041 0.000 0.000 0.080 0.042 0.000 0.000 0.000 0.000 0.000 0.203 0.000 0.000 0.000 0.000 0.000 0.000 0.038 0.000 0.000 0.038 0.000 0.000 0.000 0.149 0.000 0.000 0.226 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000

>=24.5 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 TOTAL 0.000 0.040 0.000 0.000 0.000 0.045 0.122 0.140 0.047 0.165 0.088 0.043 0.000 0.149 0.000 0.000 0.840 TOTAL HOURS OF VALID OBSERVATIONS TOTAL TOTAL TOTAL HOURS HOURS HOURS OF ELEVATED RELEASES OF STABILITY CLASS B OF ELEVATED STABILITY CLASS B 2141.000 1813.770 26.010 17.990 METEOROLOGICAL FACILITY:

BROWNS FERRY NUCLEAR PLANT STABILITY BASED ON DELTA-T BETWEEN 10.03 AND 89.59 METERS WIND DIRECTION MEASURED AT 45.74 METER LEVEL WIND SPEED MEASURED AT 45.74 METER LEVEL EFFLUENT VELOCITY = 12.60 M/S NOTE:

TOTALS AND SUBTOTALS ARE OBTAINED FROM UNROUNDED NUMBERS DATE PRINTED: 2013/05/22 E-90

BROWNS FERRY NUCLEAR PLANT UNITS 1, 2, AND 3 2013 ANNUAL RADIOACTIVE EFFLUENT RELEASE REPORT SPLIT JOINT PERCENTAGE FREQUENCIES OF WIND SPEED BY WIND DIRECTION FOR STABILITY CLASS C

(-1.7< DELTA T<=-1.5 C/100 M)

BROWNS FERRY NUCLEAR PLANT PART 2 OF 2 ELEVATED RELEASE MODE JAN 1, 2013 -

MAR 31, 2013 WIND DIRECTION N

NNE NE ENE E

ESE SE SSE S

SSW SW WSW W

WNW NW NNW SUBTOTAL WIND SPEED(MPH) 0.6-1.4 1.5-3.4 3.5-5.4 5.5-7.4 CALM 7.5-12.4 12.5-18.4 18.5-24.4 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.047 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.047 0.000 0.000 0.000 0.000 0.000 0.000 0.047 0.047 0.280 0.047 0.047 0.000 0.000 0.000 0.000 0.000 0.467 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.046 0.000 0.000 0.044 0.000 0.000 0.000 0.000 0.091 0.119 0.163 0.000 0.000 0.042 0.000 0.165 0.125 0.040 0.000 0.042 0.084 0.161 0.080 0.000 0.000 1.021 0.151 0.000 0.000 0.000 0.000 0.115 0.039 0.039 0.037 0.038 0.038 0.038 0.000 0.151 0.226 0.077 0.950 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.069 0.035 0.000 0.103

>=24.5 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.011 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.011 TOTAL 0.270 0.163 0.000 0.000 0.042 0.115 0.251 0.257 0.415 0.085 0.127 0.167 0.161 0.300 0.260 0.077 2.690 TOTAL TOTAL TOTAL TOTAL HOURS HOURS HOURS HOURS OF VALID OBSERVATIONS OF ELEVATED RELEASES OF STABILITY CLASS C OF ELEVATED STABILITY CLASS C 2141.000 1813.770 70.070 57.590 METEOROLOGICAL FACILITY:

BROWNS FERRY NUCLEAR PLANT STABILITY BASED ON DELTA-T BETWEEN 10.03 AND 89.59 METERS WIND DIRECTION MEASURED AT 45.74 METER LEVEL WIND SPEED MEASURED AT 45.74 METER LEVEL EFFLUENT VELOCITY = 12.60 M/S NOTE:

TOTALS AND SUBTOTALS ARE OBTAINED FROM UNROUNDED NUMBERS DATE PRINTED: 2013/05/22 E-91

BROWNS FERRY NUCLEAR PLANT UNITS 1, 2, AND 3 2013 ANNUAL RADIOACTIVE EFFLUENT RELEASE REPORT SPLIT JOINT PERCENTAGE FREQUENCIES OF WIND SPEED BY WIND DIRECTION FOR STABILITY CLASS D

(-1.5< DELTA T<=-0.5 C/100 M)

BROWNS FERRY NUCLEAR PLANT PART 2 OF 2 ELEVATED RELEASE MODE JAN 1, 2013 -

MAR 31, 2013 WIND DIRECTION WIND SPEED (MPH) 0.6-1.4 1.5-3.4 3.5-5.4 5.5-7.4 N

NNE NE ENE E

ESE SE SSE S

SSW SW WSW W

WNW NW NNW CALM 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000

0. 000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 7.5-12.4 12.5-18.4 18.5-24.4 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.093 0.047 0.093 0.140 0.000 0.000 0.093 0.093 0.280 0.280 0.420 0.047 0.234 0.000 0.047 0.047 1.915 0.187 0.701 0.467 0.280 0.374 0.093 0.374 0.420 0.140 0.327 0.607 0.420 0.374 0.467 0.280 0.093 5.605
0. 625 0.989 0.539 0.448 0.708 0.267 0.362 0.185 0.044 0.319 0.316 0.315 0.718 0.490 0.669 0.544 2.171 1.245 0.759 0.250 0.376 1.026 0.859 0.285 0.121 0.202 0.206 0.853 0.812 1.837 1.626 1.883 1.065 0.344 0.000 0.039 0.000 0.152 0.836 0.265 0.226 0.227 0.380 0.420 0.382 1.058 2.995 0.872 9.260 0.000 0.036 0.000 0.000 0.000 0.000 0.134 0.000 0.024 0.000 0.037 0.000 0.076 0.497 0.676 0.158 1.638

>=2 4.5 0.000 0.000 0.000 0.000 0.000 0.000 0.020 0.000 0.014 0.000 0.000 0.000 0.017 0.030 0.022 0.000 TOTAL 4.142 3.362 1.858 1.157 1.457 1.538 2.678 1.249 0.850 1.356 1.966 2.055 2.611 4.380 6.314 3.596 SUBTOTAL 7.539 14.510 0.103 40.569 TOTAL TOTAL TOTAL TOTAL HOURS HOURS HOURS HOURS OF VALID OBSERVATIONS OF ELEVATED RELEASES OF STABILITY CLASS D OF ELEVATED STABILITY CLASS D 2141.000 1813.770 983.600 868.590 METEOROLOGICAL FACILITY:

BROWNS FERRY NUCLEAR PLANT STABILITY BASED ON DELTA-T BETWEEN 10.03 AND 89.59 METERS WIND DIRECTION MEASURED AT 45.74 METER LEVEL WIND SPEED MEASURED AT 45.74 METER LEVEL EFFLUENT VELOCITY = 12.60 M/S NOTE:

TOTALS AND SUBTOTALS ARE OBTAINED FROM UNROUNDED NUMBERS DATE PRINTED: 2013/05/22 E-92

BROWNS FERRY NUCLEAR PLANT UNITS 1, 2, AND 3 2013 ANNUAL RADIOACTIVE EFFLUENT RELEASE REPORT SPLIT JOINT PERCENTAGE FREQUENCIES OF WIND SPEED BY WIND DIRECTION FOR STABILITY CLASS E

(-0.5< DELTA T<= 1.5 C/100 M)

BROWNS FERRY NUCLEAR PLANT PART 2 OF 2 ELEVATED RELEASE MODE JAN 1, 2013 -

MAR 31, 2013 WIND DIRECTION WIND SPEED(MPH) 0.6-1.4 1.5-3.4 3.5-5.4 5.5-7.4 CALM 7.5-12.4 12.5-18.4 18.5-24.4 N

NNE NE ENE E

ESE SE SSE S

SSW SW WSW W

WNW NW NNW 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.047 0.000 0.047 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.093 0.000 0.140 0.140 0.187 0.093 0.000 0.187 0.047 0.280 0.047 0.000 0.140 0.140 0.187 0.047 0.047 1.681 0.187 0.374 0.514 0.234 0.187 0.327 0.140 0.234 0.093

0. 140 0.327 0.374 0.374 0.327 0.093 0.280 4.204 0.455 0.541 0.221 0.178 0.225 0.445 0.179 0.313 0.316 0.314 0.551 0.450 0.270 0.228 0.274 0.000 1.146 1.451 1.075 0.577 0.376 1.020 1.260 0.981 0.844 0.532 1.014 0.249 0.209 0.243 0.567 1.498 0.231 0.193 0.116 0.116 0.000 0.114 1.517 0.382 0.720 0.454 0.193 0.153 0.037 0.037 0.421 0.536 5.220 0.000 0.000 0.000 0.000 0.000 0.000 0.394 0.302 0.433 0.213 0.000 0.000 0.015 0.021 0.000 0.000 1.378

>=24.5 0.000 0.000 0.000 0.000 0.000 0.000 0.010 0.027 0.026 0.011 0.000 0.000 0.000 0.007 0.000 0.000 TOTAL 2.066 2.699 2.113 1.291 0.880 1.906 3.687 2.285 2.714 1.712 2.085 1.366 1.045 1.049 1.402 2.361 SUBTOTAL 4.960 13.043 0.081 30.660 TOTAL TOTAL TOTAL TOTAL HOURS HOURS HOURS HOURS OF VALID OBSERVATIONS OF ELEVATED RELEASES OF STABILITY CLASS E OF ELEVATED STABILITY CLASS E 2141.000 1813.770 750.570 656.440 METEOROLOGICAL FACILITY:

BROWNS FERRY NUCLEAR PLANT STABILITY BASED ON DELTA-T BETWEEN 10.03 AND 89.59 METERS WIND DIRECTION MEASURED AT 45.74 METER LEVEL WIND SPEED MEASURED AT 45.74 METER LEVEL EFFLUENT VELOCITY = 12.60 M/S NOTE:

TOTALS AND SUBTOTALS ARE OBTAINED FROM UNROUNDED NUMBERS DATE PRINTED: 2013/05/22 E-93

BROWNS FERRY NUCLEAR PLANT UNITS 1, 2, AND 3 2013 ANNUAL RADIOACTIVE EFFLUENT RELEASE REPORT SPLIT JOINT PERCENTAGE FREQUENCIES OF WIND SPEED BY WIND DIRECTION FOR STABILITY CLASS F

( 1.5< DELTA T<= 4.0 C/100 M)

BROWNS FERRY NUCLEAR PLANT PART 2 OF 2 ELEVATED RELEASE MODE JAN 1, 2013 -

MAR 31, 2013 WIND DIRECTION N

NNE NE ENE E

ESE SE SSE S

SSW SW WSW W

WNW NW NNW SUBTOTAL WIND SPEED(MPH) 0.6-1.4 1.5-3.4 3.5-5.4 5.5-7.4 CALM 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 7.5-12.4 12.5-18.4 18.5-24.4 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.047 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.047 0.047 0.047 0.047 0.000 0.093 0.047 0.047 0.000 0.000 0.000 0.093 0.093 0.047 0.000 0.000 0.000 0.560 0.000 0.047 0.047 0.187 0.187 0.093 0.000 0.140 0.000 0.093 0.140 0.234 0.047 0.000 0.140 0.000 1.355 0.092 0.090 0.091 0.045 0.314 0.135 0.179 0.183 0.044 0.090 0.045 0.046 0.000 0.091 0.046 0.047 1.538 0.286 0.165 0.121 0.043 0.000 0.166 0.574 0.166 0.602 0.126 0.039 0.000 0.000 0.000 0.084 0.246 2.619 0.000 0.000 0.000 0.000 0.000 0.000 0.342 0.832 0.647 0.000 0.039 0.000 0.000 0.000 0.000 0.000 1.860 0.000 0.000 0.000 0.000 0.000 0.000 0.037 0.317 0.194 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.548

>=24.5 0.000 0.000 0.000 0.000 0.000 0.000 0.021 0.011 0.037 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.069 TOTAL 0.425 0.348 0.306 0.275 0.594 0.442 1.199 1.696 1.525 0.309 0.356 0.373 0.093 0.091 0.270 0.293 8.596 TOTAL TOTAL TOTAL TOTAL HOURS HOURS HOURS HOURS OF VALID OBSERVATIONS OF ELEVATED RELEASES OF STABILITY CLASS F OF ELEVATED STABILITY CLASS F 2141.000 1813.770 232.500 184.050 METEOROLOGICAL FACILITY:

BROWNS FERRY NUCLEAR PLANT STABILITY BASED ON DELTA-T BETWEEN 10.03 AND 89.59 METERS WIND DIRECTION MEASURED AT 45.74 METER LEVEL WIND SPEED MEASURED AT 45.74 METER LEVEL EFFLUENT VELOCITY = 12.60 M/S NOTE:

TOTALS AND SUBTOTALS ARE OBTAINED FROM UNROUNDED NUMBERS DATE PRINTED: 2013/05/22 E-94

BROWNS FERRY NUCLEAR PLANT UNITS 1, 2, AND 3 2013 ANNUAL RADIOACTIVE EFFLUENT RELEASE REPORT SPLIT JOINT PERCENTAGE FREQUENCIES OF WIND SPEED BY WIND DIRECTION FOR STABILITY CLASS G (DELTA T > 4.0 C/100 M)

BROWNS FERRY NUCLEAR PLANT PART 2 OF 2 ELEVATED RELEASE MODE JAN 1, 2013 -

MAR 31, 2013 WIND DIRECTION N

NNE NE ENE E

ESE SE SSE S

SSW SW WSW W

WNW NW NNW SUBTOTAL WIND SPEED(MPH) 0.6-1.4 1.5-3.4 3.5-5.4 5.5-7.4 CALM 7.5-12.4 12.5-18.4 18.5-24.4 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.047 0.047 0.000 0.000 0.000 0.000 0.047 0.000 0.000 0.000 0.047 0.047 0.234 0.047 0.047 0.047 0.000 0.047 0.000 0.000 0.047 0.000 0.000 0.000 0.047 0.000 0.047 0.000 0.093 0.420 0.000 0.089 0.000 0.000 0.000 0.043 0.089 0.046 0.000 0.044 0.046 0.000 0.047 0.047 0.044 0.000 0.496 0.000 0.043 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.043 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.037 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.037 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.045 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.045

>=24. 5 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 TOTAL 0.047 0.178 0.047 0.000 0.093 0.090 0.089 0.175 0.000 0.044 0.093 0.047 0.047 0.093 0.091 0.140 1.275 TOTAL HOURS OF VALID OBSERVATIONS TOTAL TOTAL TOTAL HOURS HOURS HOURS OF ELEVATED RELEASES OF STABILITY CLASS G OF ELEVATED STABILITY CLASS G 2141.000 1813.770 62.140 27.290 METEOROLOGICAL FACILITY:

BROWNS FERRY NUCLEAR PLANT STABILITY BASED ON DELTA-T BETWEEN 10.03 AND 89.59 METERS WIND DIRECTION MEASURED AT 45.74 METER LEVEL WIND SPEED MEASURED AT 45.74 METER LEVEL EFFLUENT VELOCITY = 12.60 M/S NOTE:

TOTALS AND SUBTOTALS ARE OBTAINED FROM UNROUNDED NUMBERS DATE PRINTED: 2013/05/22 E-95

BROWNS FERRY NUCLEAR PLANT UNITS 1, 2, AND 3 2013 ANNUAL RADIOACTIVE EFFLUENT RELEASE REPORT BROWNS FERRY NUCLEAR PLANT 2013 METEOROLOGICAL DATA TABLE 8B JOINT FREQUENCY DISTRIBUTION IN PERCENT FOR SPLIT LEVEL RELEASES (GROUND LEVEL RELEASE MODE AND ELEVATED RELEASE MODE)

SECOND QUARTER E-96

BROWNS FERRY NUCLEAR PLANT UNITS 1, 2, AND 3 2013 ANNUAL RADIOACTIVE EFFLUENT RELEASE REPORT SPLIT JOINT PERCENTAGE FREQUENCIES OF WIND SPEED BY WIND DIRECTION FOR STABILITY CLASS A (DELTA T<=-1.9 C/100 M)

Browns Ferry Nuclear Plant STA 52 D -

Validated Edited Data PART 1 OF 2 GROUND LEVEL RELEASE MODE APR 1, 2013 -

JUN 30, 2013 WIND DIRECTION N

NNE NE ENE E

ESE SE SSE S

SSW SW WSW W

WNW NW NNW SUBTOTAL WIND SPEED(MPH) 0.6-1.4 1.5-3.4 3.5-5.4 5.5-7.4 CALM 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 7.5-12.4 12.5-18.4 18.5-24.4 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.022 0.057 0.064 0.147 0.025 0.000 0.000 0.000 0.000 0.000 0.000 0.315 0.000 0.000 0.000 0.000 0.003 0.023 0.130 0.022 0.051 0.029 0.000 0.007 0.000 0.000 0.000 0.000 0.265 0.007 0.000 0.000 0.000 0.000 0.008 0.010 0.000 0.000 0.009 0.000 0.000 0.000 0.000 0.000 0.000 0.033 0.041 0.047 0.006 0.000 0.000 0.092 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.017 0.024 0.006 0.233 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.030 0.000 0.030 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000

>=24.5 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 TOTAL 0.047 0.047 0.006 0.000 0.003 0.145 0.198 0.086 0.198 0.063 0.000 0.007 0.000 0.017 0.054 0.006 0.877 TOTAL TOTAL TOTAL TOTAL HOURS HOURS HOURS HOURS OF VALID OBSERVATIONS OF GROUND LEVEL RELEASE OF STABILITY CLASS A OF GROUND LEVEL STABILITY CLASS A 1971.000 205.480 33.960 17.280 METEOROLOGICAL FACILITY:

Browns Ferry Nuclear Plant STA 52 D STABILITY BASED ON DELTA-T BETWEEN 10.03 AND 45.30 METERS WIND DIRECTION MEASURED AT 10.50 METER LEVEL WIND SPEED MEASURED AT 10.50 METER LEVEL EFFLUENT VELOCITY = 12.60 MIS Validated Edited Data DATE PRINTED: 2013/08/12 NOTE:

TOTALS AND SUBTOTALS ARE OBTAINED FROM UNROUNDED NUMBERS E-97

BROWNS FERRY NUCLEAR PLANT UNITS 1, 2, AND 3 2013 ANNUAL RADIOACTIVE EFFLUENT RELEASE REPORT SPLIT JOINT PERCENTAGE FREQUENCIES OF WIND SPEED BY WIND DIRECTION FOR STABILITY CLASS B

(-1.9< DELTA T<=-l.7 C/100 M)

Browns Ferry Nuclear Plant STA 52 D -

Validated Edited Data PART 1 OF 2 GROUND LEVEL RELEASE MODE APR 1, 2013 -

JUN 30, 2013 WIND DIRECTION N

NNE NE ENE E

ESE SE SSE S

SSW SW WSW W

WNW NW NNW SUBTOTAL WIND SPEED(MPH) 0.6-1.4 1.5-3.4 3.5-5.4 5.5-7.4 CALM 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 7.5-12.4 12.5-18.4 18.5-24.4 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.015 0.000 0.031 0.008 0.010 0.001 0.000 0.000 0.000 0.000 0.064 0.000 0.000 0.000 0.000 0.000 0.026 0.033 0.011 0.029 0.020 0.010 0.025 0.000 0.000 0.000 0.000 0.154 0.017 0.011 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.014 0.011 0.004 0.000 0.009 0.065 0.023 0.023 0.016 0.000 0.000 0.030 0.000 0.000 0.000 0.000 0.000 0.000 0.017 0.039 0.111 0.013 0.272 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.039 0.000 0.000 0.039 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000

>=24.5 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 TOTAL 0.040 0.034 0.016 0.000 0.000 0.056 0.048 0.011 0.060 0.027 0.020 0.040 0.027 0.082 0.111 0.022 0.594 TOTAL TOTAL TOTAL TOTAL HOURS HOURS HOURS HOURS OF VALID OBSERVATIONS OF GROUND LEVEL RELEASE OF STABILITY CLASS B OF GROUND LEVEL STABILITY CLASS B 1971.000 205.480 25.730 11.710 METEOROLOGICAL FACILITY:

Browns Ferry Nuclear Plant STA 52 D STABILITY BASED ON DELTA-T BETWEEN 10.03 AND 45.30 METERS WIND DIRECTION MEASURED AT 10.50 METER LEVEL WIND SPEED MEASURED AT 10.50 METER LEVEL EFFLUENT VELOCITY = 12.60 M/S Validated Edited Data DATE PRINTED: 2013/08/12 NOTE:

TOTALS AND SUBTOTALS ARE OBTAINED FROM UNROUNDED NUMBERS E-98

BROWNS FERRY NUCLEAR PLANT UNITS 1, 2, AND 3 2013 ANNUAL RADIOACTIVE EFFLUENT RELEASE REPORT SPLIT JOINT PERCENTAGE FREQUENCIES OF WIND SPEED BY WIND DIRECTION FOR STABILITY CLASS C

(-1.7< DELTA T<=-1.5 C/100 M)

Browns Ferry Nuclear Plant STA 52 D -

Validated Edited Data PART 1 OF 2 GROUND LEVEL RELEASE MODE APR 1, 2013 -

JUN 30, 2013 WIND DIRECTION N

NNE NE ENE E

ESE SE SSE S

SSW SW WSW W

WNW NW NNW SUBTOTAL WIND SPEED(MPH) 0.6-1.4 1.5-3.4 3.5-5.4 5.5-7.4 CALM 7.5-12.4 12.5-18.4 18.5-24.4 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.011 0.013 0.000 0.016 0.015 0.001 0.002 0.000 0.000 0.000 0.000 0.057 0.004 0.000 0.000 0.000 0.000 0.007 0.018 0.006 0.017 0.028 0.010 0.013 0.012 0.002 0.000 0.000 0.116 0.019 0.013 0.000 0.000 0.000 0.036 0.000 0.000 0.031 0.000 0.000 0.000 0.025 0.018 0.004 0.005 0.151 0.033 0.016 0.024 0.000 0.000 0.035 0.000 0.000 0.000 0.000 0.000 0.000 0.053 0.058 0.033 0.025 0.278 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.010 0.000 0.010 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000

>=24.5 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 TOTAL 0.056 0.029 0.024 0.000 0.000 0.088 0.030 0.006 0.065 0.043 0.010 0.015 0.090 0.078 0.047 0.030 0.612 TOTAL TOTAL TOTAL TOTAL HOURS HOURS HOURS HOURS OF VALID OBSERVATIONS OF GROUND LEVEL RELEASE OF STABILITY CLASS C OF GROUND LEVEL STABILITY CLASS C 1971.000 205.480 79.770 12.060 METEOROLOGICAL FACILITY:

Browns Ferry Nuclear Plant STA 52 D -

Validated Edited Data STABILITY BASED ON DELTA-T BETWEEN 10.03 AND 45.30 METERS WIND DIRECTION MEASURED AT 10.50 METER LEVEL WIND SPEED MEASURED AT 10.50 METER LEVEL EFFLUENT VELOCITY = 12.60 M/S DATE PRINTED: 2013/08/12 NOTE:

TOTALS AND SUBTOTALS ARE OBTAINED FROM UNROUNDED NUMBERS E-99

BROWNS FERRY NUCLEAR PLANT UNITS 1, 2, AND 3 2013 ANNUAL RADIOACTIVE EFFLUENT RELEASE REPORT SPLIT JOINT PERCENTAGE FREQUENCIES OF WIND SPEED BY WIND DIRECTION FOR STABILITY CLASS D

(-1.5< DELTA T<=-0.5 C/100 M)

Browns Ferry Nuclear Plant STA 52 D -

Validated Edited Data PART 1 OF 2 GROUND LEVEL RELEASE MODE APR 1, 2013 -

JUN 30, 2013 WIND DIRECTION N

NNE NE ENE E

ESE SE SSE S

SSW SW WSW W

WNW NW NNW SUBTOTAL WIND SPEED(MPH) 0.6-1.4 1.5-3.4 3.5-5.4 5.5-7.4 CALM 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 7.5-12.4 12.5-18.4 18.5-24.4

>=24.5 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.002 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.002 0.003 0.000 0.000 0.007 0.013 0.052 0.109 0.117 0.176 0.090 0.033 0.025 0.002 0.000 0.000 0.002 0.629 0.020 0.010 0.009 0.009 0.000 0.195 0.033 0.041 0.196 0.071 0.017 0.065 0.083 0.009 0.016 0.015 0.788 0.033 0.086 0.039 0.008 0.000 0.126 0.000 0.000 0.095 0.019 0.000 0.014 0.103 0.074 0.063 0.024 0.682 0.000 0.052 0.037 0.017 0.000 0.161 0.000 0.000 0.000 0.000 0.000 0.000 0.078 0.255 0.161 0.077 0.839 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.051 0.042 0.000 0.092 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 TOTAL 0.056 0.148 0.085 0.040 0.013 0.534 0.143 0.160 0.467 0.180 0.050 0.104 0.265 0.388 0.282 0.118 3.032 TOTAL TOTAL TOTAL TOTAL HOURS HOURS HOURS HOURS OF VALID OBSERVATIONS OF GROUND LEVEL RELEASE OF STABILITY CLASS D OF GROUND LEVEL STABILITY CLASS D 1971.000 205.480 868.390 59.770 METEOROLOGICAL FACILITY:

Browns Ferry Nuclear Plant STA 52 D STABILITY BASED ON DELTA-T BETWEEN 10.03 AND 45.30 METERS WIND DIRECTION MEASURED AT 10.50 METER LEVEL WIND SPEED MEASURED AT 10.50 METER LEVEL EFFLUENT VELOCITY = 12.60 M/S Validated Edited Data DATE PRINTED:

2013/08/12 NOTE:

TOTALS AND SUBTOTALS ARE OBTAINED FROM UNROUNDED NUMBERS E-100

BROWNS FERRY NUCLEAR PLANT UNITS 1, 2, AND 3 2013 ANNUAL RADIOACTIVE EFFLUENT RELEASE REPORT SPLIT JOINT PERCENTAGE FREQUENCIES OF WIND SPEED BY WIND DIRECTION FOR STABILITY CLASS E

(-0.5< DELTA T<= 1.5 C/100 M)

Browns Ferry Nuclear Plant STA 52 D -

Validated Edited Data PART 1 OF 2 GROUND LEVEL RELEASE MODE APR 1, 2013 -

JUN 30, 2013 WIND DIRECTION N

NNE NE ENE E

ESE SE SSE S

SSW SW WSW W

WNW NW NNW SUBTOTAL WIND SPEED(MPH) 0.6-1.4 1.5-3.4 3.5-5.4 5.5-7.4 CALM 7.5-12.4 12.5-18.4 18.5-24.4 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.006 0.000 0.013 0.012 0.016 0.023 0.017 0.007 0.010 0.000 0.000 0.000 0.000 0.002 0.000 0.105 0.026 0.017 0.004 0.007 0.187 0.177 0.186 0.120 0.322 0.081 0.050 0.047 0.019 0.002 0.002 0.038 1.283 0.035 0.061 0.011 0.032 0.101 0.270 0.067 0.000 0.246 0.049 0.009 0.007 0.054 0.015 0.009 0.074 1.040 0.025 0.038 0.056 0.028 0.075 0.046 0.000 0.000 0.101 0.070 0.025 0.010 0.035 0.008 0.019 0.054 0.591 0.010 0.016 0.018 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.049 0.026 0.018 0.136 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.010 0.010 0.000 0.020 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000

>=24. 5 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 TOTAL 0.096 0.138 0.089 0.080 0.375 0.508 0.277 0.136 0.676 0.210 0.083 0.064 0.109 0.083 0.068 0.184 3.175 TOTAL TOTAL TOTAL TOTAL HOURS HOURS HOURS HOURS OF VALID OBSERVATIONS OF GROUND LEVEL RELEASE OF STABILITY CLASS E OF GROUND LEVEL STABILITY CLASS E 1971.000 205.480 626.240 62.580 METEOROLOGICAL FACILITY:

Browns Ferry Nuclear Plant STA 52 D -

STABILITY BASED ON DELTA-T BETWEEN 10.03 AND 45.30 METERS WIND DIRECTION MEASURED AT 10.50 METER LEVEL WIND SPEED MEASURED AT 10.50 METER LEVEL EFFLUENT VELOCITY = 12.60 M/S NOTE:

TOTALS AND SUBTOTALS ARE OBTAINED FROM UNROUNDED NUMBERS Validated Edited Data DATE PRINTED: 2013/08/12 E-101

BROWNS FERRY NUCLEAR PLANT UNITS 1, 2, AND 3 2013 ANNUAL RADIOACTIVE EFFLUENT RELEASE REPORT SPLIT JOINT PERCENTAGE FREQUENCIES OF WIND SPEED BY WIND DIRECTION FOR STABILITY CLASS F

( 1.5< DELTA T<= 4.0 C/100 M)

Browns Ferry Nuclear Plant STA 52 D -

Validated Edited Data PART I OF 2 GROUND LEVEL RELEASE MODE APR 1, 2013 -

JUN 30, 2013 WIND DIRECTION N

NNE NE ENE E

ESE SE SSE S

SSW SW WSW W

WNW NW NNW SUBTOTAL WIND SPEED(MPH) 0.6-1.4 1.5-3.4 3.5-5.4 5.5-7.4 CALM 7.5-12.4 12.5-18.4 18.5-24.4 0.000 0.000 0.000 0.000 0.001 0.000 0.000 0.001 0.001 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.005 0.005 0.008 0.002 0.025 0.040 0.028 0.051 0.024 0.037 0.007 0.008 0.004 0.000 0.000 0.000 0.000 0.237 0.076 0.022 0.015 0.046 0.088 0.042 0.044 0.099 0.250 0.046 0.010 0.000 0.000 0.000 0.000 0.024 0.762 0.007 0.037 0.000 0.014 0.037 0.008 0.000 0.000 0.092 0.013 0.000 0.000 0.002 0.003 0.000 0.039 0.250 0.017 0.016 0.009 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.009 0.051 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.030 0.000 0.000 0.030 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000

>=24.5 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 TOTAL 0.104 0.082 0.026 0.085 0.165 0.078 0.096 0.123 0.380 0.067 0.018 0.004 0.002 0.033 0.000 0.072 1.335 TOTAL TOTAL TOTAL TOTAL HOURS HOURS HOURS HOURS OF VALID OBSERVATIONS OF GROUND LEVEL RELEASE OF STABILITY CLASS F OF GROUND LEVEL STABILITY CLASS F 1971.000 205.480 265.620 26.320 METEOROLOGICAL FACILITY:

Browns Ferry Nuclear Plant STA 52 D -

Validated Edited Data STABILITY BASED ON DELTA-T BETWEEN 10.03 AND 45.30 METERS WIND DIRECTION MEASURED AT 10.50 METER LEVEL WIND SPEED MEASURED AT 10.50 METER LEVEL EFFLUENT VELOCITY = 12.60 M/S DATE PRINTED: 2013/08/12 NOTE:

TOTALS AND SUBTOTALS ARE OBTAINED FROM UNROUNDED NUMBERS E-102

BROWNS FERRY NUCLEAR PLANT UNITS 1, 2, AND 3 2013 ANNUAL RADIOACTIVE EFFLUENT RELEASE REPORT SPLIT JOINT PERCENTAGE FREQUENCIES OF WIND SPEED BY WIND DIRECTION FOR STABILITY CLASS G (DELTA T > 4.0 C/100 M)

Browns Ferry Nuclear Plant STA 52 D -

Validated Edited Data PART 1 OF 2 GROUND LEVEL RELEASE MODE APR 1, 2013 -

JUN 30, 2013 WIND DIRECTION N

NNE NE ENE E

ESE SE SSE S

SSW SW WSW W

WNW NW NNW SUBTOTAL WIND SPEED(MPH) 0.6-1.4 1.5-3.4 3.5-5.4 5.5-7.4 CALM 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 7.5-12.4 12.5-18.4 18.5-24.4

>=24. 5 0.004 0.003 0.014 0.000 0.041 0.030 0.051 0.165 0.026 0.014 0.015 0.000 0.000 0.000 0.000 0.003 0.366 0.030 0.012 0.006 0.028 0.007 0.009 0.022 0.101 0.112 0.009 0.000 0.003 0.000 0.000 0.000 0.019 0.358 0.014 0.016 0.009 0.016 0.012 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.067 0.000 0.000 0.000 0.009 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.009 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 TOTAL 0.048 0.030 0.028 0.053 0.059 0.040 0.073 0.266 0.138 0.023 0.015 0.003 0.000 0.000 0.000 0.022 0.800 TOTAL TOTAL TOTAL TOTAL HOURS HOURS HOURS HOURS OF VALID OBSERVATIONS OF GROUND LEVEL RELEASE OF STABILITY CLASS G OF GROUND LEVEL STABILITY CLASS G 1971.000 205.480 71.290 15.760 METEOROLOGICAL FACILITY:

Browns Ferry Nuclear Plant STA 52 D STABILITY BASED ON DELTA-T BETWEEN 10.03 AND 45.30 METERS WIND DIRECTION MEASURED AT 10.50 METER LEVEL WIND SPEED MEASURED AT 10.50 METER LEVEL EFFLUENT VELOCITY = 12.60 M/S Validated Edited Data DATE PRINTED: 2013/08/12 NOTE:

TOTALS AND SUBTOTALS ARE OBTAINED FROM UNROUNDED NUMBERS E-103

BROWNS FERRY NUCLEAR PLANT UNITS 1, 2, AND 3 2013 ANNUAL RADIOACTIVE EFFLUENT RELEASE REPORT SPLIT JOINT PERCENTAGE FREQUENCIES OF WIND SPEED BY WIND DIRECTION DISREGARDING STABILITY CLASS Browns Ferry Nuclear Plant STA 52 D -

Validated Edited Data PART 1 OF 2 GROUND LEVEL RELEASE MODE APR 1, 2013 -

JUN 30, 2013 WIND DIRECTION N

NNE NE ENE E

ESE SE SSE S

SSW SW WSW W

WNW NW NNW SUBTOTAL WIND SPEED(MPH) 0.6-1.4 1.5-3.4 3.5-5.4 5.5-7.4 CALM 0.000 0.000 0.000 0.000 0.000 0.000 0.001 0.001 0.001 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.004 7.5-12.4 12.5-18.4 18.5-24.4

>=24. 5 0.007 0.021 0.027 0.042 0.090 0.067 0.123 0.189 0.064 0.028 0.021 0.003 0.000 0.000 0.002 0.003 0.687 0.128 0.048 0.026 0.087 0.321 0.301 0.439 0.470 1.002 0.270 0.101 0.071 0.019 0.006 0.001 0.076 3.365 0.072 0.113 0.027 0.089 0.178 0.592 0.271 0.086 0.593 0.233 0.049 0.106 0.138 0.025 0.023 0.124 2.718 0.115 0.149 0.151 0.051 0.076 0.438 0.009 0.000 0.207 0.089 0.023 0.035 0.163 0.094 0.078 0.109 1.788 0.102 0.140 0.092 0.015 0.000 0.359 0.000 0.000 0.000 0.000 0.000 0.000 0.158 0.398 0.324 0.144 1.733 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.166 0.093 0.000 0.259 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 TOTAL 0.425 0.471 0.323 0.284 0.665 1.758 0.843 0.746 1.867

0. 620 0.194 0.215 0.478 0.689 0.520 0.456 0.000 10.555 TOTAL HOURS OF VALID OBSERVATIONS TOTAL HOURS OF OBSERVATIONS RECOVERABILITY PERCENTAGE TOTAL HOURS OF GROUND LEVEL RELEASE 2166.000 2184.000 99.176 228.620 METEOROLOGICAL FACILITY:

Browns Ferry Nuclear Plant STA 52 D WIND DIRECTION MEASURED AT 10.50 METER LEVEL WIND SPEED MEASURED AT 10.50 METER LEVEL EFFLUENT VELOCITY = 12.60 M/S Validated Edited Data DATE PRINTED: 2013/08/12 NOTE:

TOTALS AND SUBTOTALS ARE OBTAINED FROM UNROUNDED NUMBERS E-104

BROWNS FERRY NUCLEAR PLANT UNITS 1, 2, AND 3 2013 ANNUAL RADIOACTIVE EFFLUENT RELEASE REPORT SPLIT JOINT PERCENTAGE FREQUENCIES OF WIND SPEED BY WIND DIRECTION FOR STABILITY CLASS A (DELTA T<=-1.9 C/100 M)

Browns Ferry Nuclear Plant STA 52 D -

Validated Edited Data PART 2 OF 2 ELEVATED RELEASE MODE APR 1, 2013 -

JUN 30, 2013 WIND DIRECTION N

NNE NE ENE E

ESE SE SSE S

SSW SW WSW W

WNW NW NNW SUBTOTAL WIND SPEED(MPH) 0.6-1.4 1.5-3.4 3.5-5.4 5.5-7.4 CALM 7.5-12.4 12.5-18.4 18.5-24.4 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.051 0.000 0.000 0.000 0.000 0.000 0.051 0.000 0.000 0.000 0.000 0.000 0.000 0.147 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.147 0.000 0.000 0.000 0.000 0.000 0.000 0.180 0.179 0.000 0.000 0.000 0.000 0.000 0.000 0.043 0.000 0.401 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.165 0.082 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.248 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000

>=24. 5 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 TOTAL 0.000 0.000 0.000 0.000 0.000 0.000 0.327 0.344 0.082 0.000 0.051 0.000 0.000 0.000 0.043 0.000 0.846 TOTAL TOTAL TOTAL TOTAL HOURS HOURS HOURS HOURS OF VALID OBSERVATIONS OF ELEVATED RELEASES OF STABILITY CLASS A OF ELEVATED STABILITY CLASS A 1971.000 1765.520 33.960 16.680 METEOROLOGICAL FACILITY:

Browns Ferry Nuclear Plant STA 52 D -

Validated Edited Data STABILITY BASED ON DELTA-T BETWEEN 10.03 AND 89.59 METERS WIND DIRECTION MEASURED AT 45.74 METER LEVEL WIND SPEED MEASURED AT 45.74 METER LEVEL EFFLUENT VELOCITY = 12.60 MIS DATE PRINTED: 2013/08/12 NOTE:

TOTALS AND SUBTOTALS ARE OBTAINED FROM UNROUNDED NUMBERS E-105

BROWNS FERRY NUCLEAR PLANT UNITS 1, 2, AND 3 2013 ANNUAL RADIOACTIVE EFFLUENT RELEASE REPORT SPLIT JOINT PERCENTAGE FREQUENCIES OF WIND SPEED BY WIND DIRECTION FOR STABILITY CLASS B

(-1.9< DELTA T<=-1.7 C/100 M)

Browns Ferry Nuclear Plant STA 52 D -

Validated Edited Data PART 2 OF 2 ELEVATED RELEASE MODE APR 1, 2013 -

JUN 30, 2013 WIND DIRECTION N

NNE NE ENE E

ESE SE SSE S

SSW SW WSW W

WNW NW NNW SUBTOTAL WIND SPEED(MPH) 0.6-1.4 1.5-3.4 3.5-5.4 5.5-7.4 CALM 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 7.5-12.4 12.5-18.4 18.5-24.4 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.097 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.097 0.044 0.043 0.000 0.000 0.000 0.000 0.183 0.088 0.045 0.045 0.000 0.000 0.000 0.000 0.000 0.000 0.447 0.084 0.042 0.000 0.000 0.000 0.000 0.000 0.041 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.167 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000

>=24.5 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 TOTAL 0.128 0.085 0.000 0.000 0.000 0.000 0.280 0.129 0.045 0.045 0.000 0.000 0.000 0.000 0.000 0.000 0.711 TOTAL TOTAL TOTAL TOTAL HOURS HOURS HOURS HOURS OF VALID OBSERVATIONS OF ELEVATED RELEASES OF STABILITY CLASS B OF ELEVATED STABILITY CLASS B 1971.000 1765.520 25.730 14.020 METEOROLOGICAL FACILITY:

Browns Ferry Nuclear Plant STA 52 D -

Validated Edited Data STABILITY BASED ON DELTA-T BETWEEN 10.03 AND 89.59 METERS WIND DIRECTION MEASURED AT 45.74 METER LEVEL WIND SPEED MEASURED AT 45.74 METER LEVEL EFFLUENT VELOCITY = 12.60 M/S DATE PRINTED: 2013/08/12 NOTE:

TOTALS AND SUBTOTALS ARE OBTAINED FROM UNROUNDED NUMBERS E-1 06

BROWNS FERRY NUCLEAR PLANT UNITS 1, 2, AND 3 2013 ANNUAL RADIOACTIVE EFFLUENT RELEASE REPORT SPLIT JOINT PERCENTAGE FREQUENCIES OF WIND SPEED BY WIND DIRECTION FOR STABILITY CLASS C

(-1.7< DELTA T<=-1.5 C/100 M)

Browns Ferry Nuclear Plant STA 52 D -

Validated Edited Data PART 2 OF 2 ELEVATED RELEASE MODE APR 1, 2013 -

JUN 30, 2013 WIND DIRECTION N

NNE NE ENE E

ESE SE SSE S

SSW SW WSW W

WNW NW NNW SUBTOTAL WIND SPEED(MPH) 0.6-1.4 1.5-3.4 3.5-5.4 5.5-7.4 CALM 7.5-12.4 12.5-18.4 18.5-24.4 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.051 0.051 0.000 0.000 0.000 0.000 0.203 0.254 0.051 0.101 0.000 0.051 0.051 0.051 0.000 0.000 0.863 0.000 0.000 0.000 0.000 0.000 0.000 0.290 0.099 0.098 0.000 0.097 0.150 0.000 0.000 0.000 0.000 0.735 0.218 0.350 0.045 0.000 0.000 0.000 0.364 0.000 0.131 0.045 0.000 0.047 0.000 0.000 0.088 0.045 1.332 0.000 0.000 0.000 0.000 0.000 0.000 0.082 0.000 0.083 0.000 0.000 0.000 0.000 0.208 0.082 0.000 0.455 0.000 0.000 0.000 0.000 0.000 0.000 0.027 0.024 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.051

>=24.5 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 TOTAL 0.269 0.400 0.045 0.000 0.000 0.000 0.966 0.377 0.363 0.147 0.097 0.248 0.051 0.259 0.170 0.045 3.435 TOTAL HOURS OF VALID OBSERVATIONS TOTAL TOTAL TOTAL HOURS HOURS HOURS OF ELEVATED RELEASES OF STABILITY CLASS C OF ELEVATED STABILITY CLASS C 1971.000 1765.520 79.770 67.710 METEOROLOGICAL FACILITY:

Browns Ferry Nuclear Plant STA 52 D -

Validated Edited Data STABILITY BASED ON DELTA-T BETWEEN 10.03 AND 89.59 METERS WIND DIRECTION MEASURED AT 45.74 METER LEVEL WIND SPEED MEASURED AT 45.74 METER LEVEL EFFLUENT VELOCITY = 12.60 M/S DATE PRINTED: 2013/08/12 NOTE:

TOTALS AND SUBTOTALS ARE OBTAINED FROM UNROUNDED NUMBERS E-107

BROWNS FERRY NUCLEAR PLANT UNITS 1, 2, AND 3 2013 ANNUAL RADIOACTIVE EFFLUENT RELEASE REPORT SPLIT JOINT PERCENTAGE FREQUENCIES OF WIND SPEED BY WIND DIRECTION FOR STABILITY CLASS D

(-1.5< DELTA T<=-0.5 C/100 M)

Browns Ferry Nuclear Plant STA 52 D -

Validated Edited Data PART 2 OF 2 ELEVATED RELEASE MODE APR 1, 2013 -

JUN 30, 2013 WIND DIRECTION N

NNE NE ENE E

ESE SE SSE S

SSW SW WSW W

WNW NW NNW SUBTOTAL WIND SPEED(MPH) 0.6-1.4 1.5-3.4 3.5-5.4 5.5-7.4 CALM 7.5-12.4 12.5-18.4 18.5-24.4 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.051 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.051 0.051 0.000 0.000 0.051 0.000 0.203 0.304 0.609 0.355 0.609 0.609 0.152 0.406 0.101 0.000 0.101 3.551 0.101 0.304 0.304 0.152 0.051 0.101 0.660 0.304 0.558 0.710 0.964 0.812 0.507 0.457 0.355 0.152 6.494 0.443 0.196 0.146 0.192 0.050 0.193 0.730 0.490 0.925 0.587 0.730 0.584 0.925 0.837 0.242 0.542 7.811 0.797 1.108 0.667 0.223 0.179 0.261 1.693 1.520 1.250 0.757 0.627 0.632 1.385 1.911 1.874 0.592 15.475 0.126 0.293 0.211 0.042 0.000 0.084 1.030 0.829 0.994 0.911 0.083 0.083 0.331 0.952 0.706 0.208 6.881 0.035 0.000 0.000 0.000 0.000 0.000 0.143 0.114 0.312 0.039 0.000 0.000 0.000 0.040 0.029 0.000 0.711

>=24.5 0.000 0.000 0.000 0.000 0.000 0.000 0.029 0.022 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 TOTAL 1.554 1.951 1.328 0.659 0.280 0.842 4.589 3.888 4.394 3.613 3.012 2.263 3.554 4.298 3.206 1.595 0.051 41.026 TOTAL TOTAL TOTAL TOTAL HOURS HOURS HOURS HOURS OF VALID OBSERVATIONS OF ELEVATED RELEASES OF STABILITY CLASS D OF ELEVATED STABILITY CLASS D 1971.000 1765.520 868.390 808.620 METEOROLOGICAL FACILITY:

Browns Ferry Nuclear Plant STA 52 D STABILITY BASED ON DELTA-T BETWEEN 10.03 AND 89.59 METERS WIND DIRECTION MEASURED AT 45.74 METER LEVEL WIND SPEED MEASURED AT 45.74 METER LEVEL EFFLUENT VELOCITY = 12.60 M/S Validated Edited Data DATE PRINTED: 2013/08/12 NOTE:

TOTALS AND SUBTOTALS ARE OBTAINED FROM UNROUNDED NUMBERS E-108

BROWNS FERRY NUCLEAR PLANT UNITS 1, 2, AND 3 2013 ANNUAL RADIOACTIVE EFFLUENT RELEASE REPORT SPLIT JOINT PERCENTAGE FREQUENCIES OF WIND SPEED BY WIND DIRECTION FOR STABILITY CLASS E

(-0.5< DELTA T<= 1.5 C/100 M)

Browns Ferry Nuclear Plant STA 52 D -

Validated Edited Data PART 2 OF 2 ELEVATED RELEASE MODE APR 1, 2013 -

JUN 30, 2013 WIND DIRECTION WIND SPEED(MPH) 0.6-1.4 1.5-3.4 3.5-5.4 5.5-7.4 CALM 7.5-12.4 12.5-18.4 18.5-24.4 N

NNE NE ENE E

ESE SE SSE S

SSW SW WSW W

WNW NW NNW 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.051 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.051 0.051 0.000 0.152 0.203 0.101 0.000 0.051 0.000 0.051 0.051 0.304 0.355 0.101 0.051 0.051 0.101 1.624 0.203 0.051 0.101 0.101 0.152 0.355 0.304 0.304 0.304 0.558 0.660 0.558 0.812 0.355 0.254 0.152 5.226 0.097 0.385 0.245 0.145 0.145 0.246 0.681 0.778 0.875 0.098 0.386 0.399 0.443 0.438 0.343 0.242 0.987 0.398 0.531 0.090 0.267 1.155 1.169 1.167 1.799 0.669 0.363 0.046 0.366 0.225 0.138 0.659 0.251 0.000 0.041 0.000 0.000 0.166 0.784 1.356 1.573 0.124 0.000 0.000 0.000 0.284 0.125 0.168 4.873 0.000 0.000 0.000 0.000 0.000 0.000 0.091 0.155 0.450 0.082 0.000 0.000 0.000 0.000 0.040 0.000 0.818

>=24. 5 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.015 0.017 0.000 0.000 0.000 0.000 0.000 0.000 0.000 TOTAL 1.589 0.884 1.071 0.539 0.666 1.922 3.081 3.776 5.068 1.582 1.713 1.358 1.723 1.353 0.950 1.323 SUBTOTAL 5.945 10.029 0.032 28.598 TOTAL TOTAL TOTAL TOTAL HOURS HOURS HOURS HOURS OF VALID OBSERVATIONS OF ELEVATED RELEASES OF STABILITY CLASS E OF ELEVATED STABILITY CLASS E 1971.000 1765.520 626.240 563.660 METEOROLOGICAL FACILITY:

Browns Ferry Nuclear Plant STA 52 D -

Validated Edited Data STABILITY BASED ON DELTA-T BETWEEN 10.03 AND 89.59 METERS WIND DIRECTION MEASURED AT 45.74 METER LEVEL WIND SPEED MEASURED AT 45.74 METER LEVEL EFFLUENT VELOCITY = 12.60 M/S DATE PRINTED: 2013/08/12 NOTE:

TOTALS AND SUBTOTALS ARE OBTAINED FROM UNROUNDED NUMBERS E-109

BROWNS FERRY NUCLEAR PLANT UNITS 1, 2, AND 3 2013 ANNUAL RADIOACTIVE EFFLUENT RELEASE REPORT SPLIT JOINT PERCENTAGE FREQUENCIES OF WIND SPEED BY WIND DIRECTION FOR STABILITY CLASS F

( 1.5< DELTA T<= 4.0 C/100 M)

Browns Ferry Nuclear Plant STA 52 D -

Validated Edited Data PART 2 OF 2 ELEVATED RELEASE MODE APR 1, 2013 -

JUN 30, 2013 WIND DIRECTION N

NNE NE ENE E

ESE SE SSE S

SSW SW WSW W

WNW NW NNW SUBTOTAL WIND SPEED(MPH) 0.6-1.4 1.5-3.4 3.5-5.4 5.5-7.4 CALM 7.5-12.4 12.5-18.4 18.5-24.4 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000

0. 000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.051 0.000 0.000 0.000 0.051 0.101 0.101 0.000 0.000 0.000 0.051 0.000 0.000 0.000 0.000 0.101 0.000 0.051 0.051 0.101 0.051 0.051 0.558 0.051 0.051 0.000 0.051 0.152 0.101 0.203 0.101 0.152 0.304 0.355 0.152 0.355 0.203 0.152 0.152 2.537 0.097 0.047 0.098 0.049 0.097 0.191 0.394 0.150 0.144 0.193 0.191 0.099 0.096 0.098 0.048 0.049 2.042 0.405 0.179 0.661 0.221 0.446 0.631 0.366 0.610 1.012 0.533 0.047 0.000 0.000 0.046 0.047 0.132 5.336 0.042 0.084 0.000 0.084 0.000 0.000 0.042 0.496 0.622 0.084 0.000 0.000 0.000 0.000 0.000 0.000 1.454 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.033 0.079 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.113

>=24. 5 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 TOTAL 0.697 0.361 0.758 0.405 0.747 0.924 1.004 1.391 2.010 1.216 0.593 0.353 0.502 0.449 0.298 0.435 0.000 12.141 TOTAL TOTAL TOTAL TOTAL HOURS HOURS HOURS HOURS OF VALID OBSERVATIONS OF ELEVATED RELEASES OF STABILITY CLASS F OF ELEVATED STABILITY CLASS F 1971.000 1765.520 265.620 239.300 METEOROLOGICAL FACILITY:

Browns Ferry Nuclear Plant STA 52 D -

Validated Edited Data STABILITY BASED ON DELTA-T BETWEEN 10.03 AND 89.59 METERS WIND DIRECTION MEASURED AT 45.74 METER LEVEL WIND SPEED MEASURED AT 45.74 METER LEVEL EFFLUENT VELOCITY = 12.60 M/S DATE PRINTED: 2013/08/12 NOTE:

TOTALS AND SUBTOTALS ARE OBTAINED FROM UNROUNDED NUMBERS E-110

BROWNS FERRY NUCLEAR PLANT UNITS 1, 2, AND 3 2013 ANNUAL RADIOACTIVE EFFLUENT RELEASE REPORT SPLIT JOINT PERCENTAGE FREQUENCIES OF WIND SPEED BY WIND DIRECTION FOR STABILITY CLASS G (DELTA T > 4.0 C/100 M)

Browns Ferry Nuclear Plant STA 52 D -

Validated Edited Data PART 2 OF 2 ELEVATED RELEASE MODE APR 1, 2013 -

JUN 30, 2013 WIND DIRECTION N

NNE NE ENE E

ESE SE SSE S

SSW SW WSW W

WNW NW NNW SUBTOTAL WIND SPEED(MPH) 0.6-1.4 1.5-3.4 3.5-5.4 5.5-7.4 CALM 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 7.5-12.4 12.5-18.4 18.5-24.4 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.051 0.000 0.051 0.000 0.000 0.051 0.000 0.000 0.000 0.152 0.000 0.000 0.152 0.000 0.000 0.000 0.101 0.000 0.000 0.000 0.000 0.000 0.051 0.051 0.000 0.000 0.355 0.051 0.101 0.000 0.203 0.051 0.051 0.101 0.051 0.000 0.000 0.000 0.101 0.000 0.000 0.051 0.051 0.812 0.000 0.000 0.098 0.197 0.048 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.343 0.088 0.091 0.000 0.046 0.133 0.043 0.000 0.045 0.085 0.000 0.000 0.000 0.000 0.000 0.046 0.000 0.577 0.000 0.000 0.000 0.042 0.000 0.000 0.000 0.289 0.206 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.538 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.040 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.040

>=24.5 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 TOTAL 0.139 0.192 0.250 0.489 0.232 0.094 0.203 0.475 0.292 0.051 0.000 0.101 0.101 0.051 0.096 0.051 2.817 TOTAL TOTAL TOTAL TOTAL HOURS HOURS HOURS HOURS OF VALID OBSERVATIONS OF ELEVATED RELEASES OF STABILITY CLASS G OF ELEVATED STABILITY CLASS G 1971.000 1765.520 71.290 55.530 METEOROLOGICAL FACILITY:

Browns Ferry Nuclear Plant STA 52 D -

Validated Edited Data STABILITY BASED ON DELTA-T BETWEEN 10.03 AND 89.59 METERS WIND DIRECTION MEASURED AT 45.74 METER LEVEL WIND SPEED MEASURED AT 45.74 METER LEVEL EFFLUENT VELOCITY = 12.60 M/S DATE PRINTED: 2013/08/12 NOTE:

TOTALS AND SUBTOTALS ARE OBTAINED FROM UNROUNDED NUMBERS E-111

BROWNS FERRY NUCLEAR PLANT UNITS 1, 2, AND 3 2013 ANNUAL RADIOACTIVE EFFLUENT RELEASE REPORT SPLIT JOINT PERCENTAGE FREQUENCIES OF WIND SPEED BY WIND DIRECTION DISREGARDING STABILITY CLASS Browns Ferry Nuclear Plant STA 52 D -

Validated Edited Data PART 2 OF 2 ELEVATED RELEASE MODE APR 1, 2013 -

JUN 30, 2013 WIND DIRECTION WIND SPEED(MPH) 0.6-1.4 1.5-3.4 3.5-5.4 5.5-7.4 N

NNE NE ENE E

ESE SE SSE S

SSW SW WSW W

WNW NW NNW CALM 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 7.5-12.4 12.5-18.4 18.5-24.4 0.000

0. 092 0.000 0.000 0.000 0.000 0.000 0.046 0.000 0.046 0.000 0.046 0.046 0.000 0.000 0.046 0.323 0.323 0.000 0.277 0.231 0.139 0.185 0.462 0.646 0.369 0.739 0.831 0.554 0.554 0.277 0.139 0.231 0.462 0.508 0.416 0.462 0.369 0.693 1.524 0.970 1.108 1.616 1.847 1.524 1.616 0.970 0.739 0.508 0.580 0.572
0. 622 0.531 0.353 0.836 2.614 1.513 1.858 0.844 1.277 1.121 1.421 1.295 0.622 0.759 2.559 1.972 1.934 0.767 1.096 2.743 4.131 3.445 4.415 1.946 0.943 0.659
1. 673 1.986 2.034 1.460 0.458 0.381 0.306 0.152 0.000 0.721 2.625 2.891 3.428 1.284 0.076 0.075 0.415
1. 535 0.867 0.380 0.031 0.000 0.000 0.000 0.000 0.000 0.249 0.334 0.765 0.110 0.000 0.000 0.000 0.036
0. 063 0.000 1.589

>=24.5 0.000 0.000 0.000 0.000 0.000 0.000 0.026 0.034 0.015 0.000 0.000 0.000 0.000 0.000 0.000 0.000 TOTAL 4.414 3.525 3.554 2.143 1.957 5.177 11.631 9.878 11.958 6.584

4. 973 3.980 5.724 6.099 4.464 3.384 SUBTOTAL 5.956 15.328 16.818 33.762 15.594 0.075 89.445 TOTAL HOURS OF VALID OBSERVATIONS TOTAL HOURS OF OBSERVATIONS RECOVERABILITY PERCENTAGE TOTAL HOURS OF ELEVATED RELEASES 2166.000 2184.000 99.176 1937.380 METEOROLOGICAL FACILITY:

Browns Ferry Nuclear Plant STA 52 D WIND DIRECTION MEASURED AT 45.74 METER LEVEL WIND SPEED MEASURED AT 45.74 METER LEVEL EFFLUENT VELOCITY = 12.60 M/S Validated Edited Data DATE PRINTED: 2013/08/12 NOTE:

TOTALS AND SUBTOTALS ARE OBTAINED FROM UNROUNDED NUMBERS E-112

BROWNS FERRY NUCLEAR PLANT UNITS 1, 2, AND 3 2013 ANNUAL RADIOACTIVE EFFLUENT RELEASE REPORT BROWNS FERRY NUCLEAR PLANT 2013 METEOROLOGICAL DATA TABLE 8C JOINT FREQUENCY DISTRIBUTION IN PERCENT FOR SPLIT LEVEL RELEASES (GROUND LEVEL RELEASE MODE AND ELEVATED RELEASE MODE)

THIRD QUARTER E-1 13

BROWNS FERRY NUCLEAR PLANT UNITS 1, 2, AND 3 2013 ANNUAL RADIOACTIVE EFFLUENT RELEASE REPORT SPLIT JOINT PERCENTAGE FREQUENCIES OF WIND SPEED BY WIND DIRECTION FOR STABILITY CLASS A (DELTA T<=-1.9 C/100 M)

BROWNS FERRY NUCLEAR PLANT PART 1 OF 2 GROUND LEVEL RELEASE MODE JUL 1, 2013 -

SEP 30, 2013 WIND DIRECTION N

NNE NE ENE E

ESE SE SSE S

SSW SW WSW W

WNW NW NNW SUBTOTAL WIND SPEED(MPH) 0.6-1.4 1.5-3.4 3.5-5.4 5.5-7.4 CALM 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 7.5-12.4 12.5-18.4 18.5-24.4 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.008 0.031 0.044 0.034 0.012 0.003 0.000 0.000 0.000 0.000 0.000 0.133 0.000 0.000 0.000 0.000 0.009 0.070 0.103 0.016 0.006 0.005 0.000 0.003 0.004 0.000 0.000 0.000 0.216 0.001 0.000 0.000 0.000 0.000 0.043 0.000 0.000 0.000 0.000 0.000 0.000 0.020 0.004 0.000 0.010 0.077 0.015 0.015 0.021 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.005 0.036 0.019 0.027 0.137 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.009 0.000 0.000 0.009 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000

>=24.5 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 TOTAL 0.016 0.015 0.021 0.000 0.009 0.121 0.134 0.059 0.040 0.018 0.003 0.003 0.028 0.049 0.019 0.037 0.572 TOTAL TOTAL TOTAL TOTAL HOURS HOURS HOURS HOURS OF VALID OBSERVATIONS OF GROUND LEVEL RELEASE OF STABILITY CLASS A OF GROUND LEVEL STABILITY CLASS A 2187.000 132.510 22.530 12.500 METEOROLOGICAL FACILITY:

BROWNS FERRY NUCLEAR PLANT STABILITY BASED ON DELTA-T BETWEEN 10.03 AND 45.30 METERS WIND DIRECTION MEASURED AT 10.50 METER LEVEL WIND SPEED MEASURED AT 10.50 METER LEVEL EFFLUENT VELOCITY = 12.60 M/S NOTE:

TOTALS AND SUBTOTALS ARE OBTAINED FROM UNROUNDED NUMBERS DATE PRINTED: 2013/11/15 E-114

BROWNS FERRY NUCLEAR PLANT UNITS 1, 2, AND 3 2013 ANNUAL RADIOACTIVE EFFLUENT RELEASE REPORT SPLIT JOINT PERCENTAGE FREQUENCIES OF WIND SPEED BY WIND DIRECTION FOR STABILITY CLASS B

(-1.9< DELTA T<=-1.7 C/100 M)

BROWNS FERRY NUCLEAR PLANT PART 1 OF 2 GROUND LEVEL RELEASE MODE JUL 1, 2013 -

SEP 30, 2013 WIND DIRECTION N

NNE NE ENE E

ESE SE SSE S

SSW SW WSW W

WNW NW NNW SUBTOTAL WIND SPEED(MPH) 0.6-1.4 1.5-3.4 3.5-5.4 5.5-7.4 CALM 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 7.5-12.4 12.5-18.4 18.5-24.4 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.019 0.001 0.003 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.023 0.000 0.000 0.001 0.000 0.000 0.035 0.016 0.000 0.000 0.000 0.000 0.002 0.007 0.000 0.000 0.000 0.062 0.003 0.016 0.000 0.000 0.000 0.016 0.000 0.000 0.000 0.000 0.000 0.000 0.012 0.004 0.017 0.026 0.094 0.044 0.044 0.011 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.018 0.042 0.023 0.182 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000

>=24.5 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 TOTAL 0.048 0.060 0.013 0.000 0.000 0.052 0.035 0.001 0.003 0.000 0.000 0.002 0.019 0.021 0.059 0.049 0.362 TOTAL TOTAL TOTAL TOTAL HOURS HOURS HOURS HOURS OF VALID OBSERVATIONS OF GROUND LEVEL RELEASE OF STABILITY CLASS B OF GROUND LEVEL STABILITY CLASS B 2187.000 132.510 43.100 7.910 METEOROLOGICAL FACILITY:

BROWNS FERRY NUCLEAR PLANT STABILITY BASED ON DELTA-T BETWEEN 10.03 AND 45.30 METERS WIND DIRECTION MEASURED AT 10.50 METER LEVEL WIND SPEED MEASURED AT 10.50 METER LEVEL EFFLUENT VELOCITY = 12.60 M/S NOTE:

TOTALS AND SUBTOTALS ARE OBTAINED FROM UNROUNDED NUMBERS DATE PRINTED: 2013/11/15 E-115

BROWNS FERRY NUCLEAR PLANT UNITS 1, 2, AND 3 2013 ANNUAL RADIOACTIVE EFFLUENT RELEASE REPORT SPLIT JOINT PERCENTAGE FREQUENCIES OF WIND SPEED BY WIND DIRECTION FOR STABILITY CLASS C

(-1.7< DELTA T<=-1.5 C/100 M)

BROWNS FERRY NUCLEAR PLANT PART 1 OF 2 GROUND LEVEL RELEASE MODE JUL 1, 2013 -

SEP 30, 2013 WIND DIRECTION N

NNE NE ENE E

ESE SE SSE S

SSW SW WSW W

WNW NW NNW SUBTOTAL WIND SPEED(MPH) 0.6-1.4 1.5-3.4 3.5-5.4 5.5-7.4 CALM 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 7.5-12.4 12.5-18.4 18.5-24.4

>=24.5 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.015 0.009 0.011 0.010 0.006 0.000 0.000 0.000 0.000 0.000 0.000 0.051 0.002 0.002 0.000 0.001 0.000 0.012 0.005 0.000 0.000 0.000 0.000 0.006 0.009 0.003 0.001 0.002 0.043 0.018 0.026 0.004 0.000 0.005 0.021 0.000 0.000 0.000 0.000 0.000 0.000 0.011 0.008 0.000 0.029 0.122 0.014 0.012 0.006 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.008 0.032 0.017 0.027 0.117 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 TOTAL 0.034 0.040 0.011 0.001 0.005 0.049 0.014 0.011 0.010 0.006 0.000 0.007

0. 027 0.043 0.018 0.058 0.332 TOTAL TOTAL TOTAL TOTAL HOURS HOURS HOURS HOURS OF VALID OBSERVATIONS OF GROUND LEVEL RELEASE OF STABILITY CLASS C OF GROUND LEVEL STABILITY CLASS C 2187.000 132.510 105.650 7.270 METEOROLOGICAL FACILITY:

BROWNS FERRY NUCLEAR PLANT STABILITY BASED ON DELTA-T BETWEEN 10.03 AND 45.30 METERS WIND DIRECTION MEASURED AT 10.50 METER LEVEL WIND SPEED MEASURED AT 10.50 METER LEVEL EFFLUENT VELOCITY = 12.60 M/S NOTE:

TOTALS AND SUBTOTALS ARE OBTAINED FROM UNROUNDED NUMBERS DATE PRINTED: 2013/11/15 E-1 16

BROWNS FERRY NUCLEAR PLANT UNITS 1, 2, AND 3 2013 ANNUAL RADIOACTIVE EFFLUENT RELEASE REPORT SPLIT JOINT PERCENTAGE FREQUENCIES OF WIND SPEED BY WIND DIRECTION FOR STABILITY CLASS D

(-1.5< DELTA T<=-0.5 C/100 M)

BROWNS FERRY NUCLEAR PLANT PART 1 OF 2 GROUND LEVEL RELEASE MODE JUL 1, 2013 -

SEP 30, 2013 WIND DIRECTION N

NNE NE ENE E

ESE SE SSE S

SSW SW WSW W

WNW NW NNW SUBTOTAL WIND SPEED(MPH) 0.6-1.4 1.5-3.4 3.5-5.4 5.5-7.4 CALM 7.5-12.4 12.5-18.4 18.5-24.4 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.005 0.000 0.002 0.000 0.000 0.000 0.000 0.000 0.007 0.000 0.000 0.000 0.000 0.043 0.134 0.099 0.052 0.075 0.055 0.005 0.012 0.000 0.000 0.000 0.000 0.477 0.023 0.039 0.004 0.029 0.271 0.297 0.007 0.005 0.000 0.009 0.000 0.016 0.045 0.003 0.013 0.010 0.769 0.052 0.031 0.016 0.007 0.041 0.192 0.000 0.000 0.000 0.000 0.000 0.000 0.033 0.031 0.019 0.037 0.459 0.031 0.045 0.011 0.000 0.008 0.040 0.000 0.000 0.000 0.000 0.000 0.000 0.015 0.024 0.022 0.016 0.213 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.026 0.000 0.026 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000

>=24.5 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 TOTAL 0.106 0.115 0.031 0.036 0.363 0.662 0.106 0.058 0.081 0.064 0.007 0.028 0.092 0.058 0.080 0.063 1.951 TOTAL TOTAL TOTAL TOTAL HOURS HOURS HOURS HOURS OF VALID OBSERVATIONS OF GROUND LEVEL RELEASE OF STABILITY CLASS D OF GROUND LEVEL STABILITY CLASS D 2187.000 132.510 999.570 42.660 METEOROLOGICAL FACILITY:

BROWNS FERRY NUCLEAR PLANT STABILITY BASED ON DELTA-T BETWEEN 10.03 AND 45.30 METERS WIND DIRECTION MEASURED AT 10.50 METER LEVEL WIND SPEED MEASURED AT 10.50 METER LEVEL EFFLUENT VELOCITY = 12.60 M/S NOTE:

TOTALS AND SUBTOTALS ARE OBTAINED FROM UNROUNDED NUMBERS DATE PRINTED: 2013/11/15 E-117

BROWNS FERRY NUCLEAR PLANT UNITS 1, 2, AND 3 2013 ANNUAL RADIOACTIVE EFFLUENT RELEASE REPORT SPLIT JOINT PERCENTAGE FREQUENCIES OF WIND SPEED BY WIND DIRECTION FOR STABILITY CLASS E

(-0.5< DELTA T<= 1.5 C/100 M)

BROWNS FERRY NUCLEAR PLANT PART 1 OF 2 GROUND LEVEL RELEASE MODE JUL 1, 2013 -

SEP 30, 2013 WIND DIRECTION N

NNE NE ENE E

ESE SE SSE S

SSW SW WSW W

WNW NW NNW SUBTOTAL WIND SPEED(MPH) 0.6-1.4 1.5-3.4 3.5-5.4 5.5-7.4 CALM 7.5-12.4 12.5-18.4 18.5-24.4 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.005 0.007 0.000 0.005 0.007 0.005 0.004 0.005 0.003 0.000 0.000 0.000 0.000 0.000 0.042 0.049 0.054 0.010 0.043 0.226 0.120 0.054 0.024 0.033 0.023 0.019 0.000 0.005 0.001 0.008 0.040 0.710 0.086 0.133 0.047 0.035 0.340 0.254 0.000 0.009 0.002 0.006 0.000 0.004 0.014 0.005 0.001 0.062 0.999 0.000 0.059 0.039 0.000 0.015 0.017 0.000 0.000 0.008 0.000 0.000 0.000 0.005 0.000 0.005 0.005 0.153 0.000 0.000 0.007 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.007 0.016 0.000 0.007 0.037 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.009 0.000 0.009 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000

>=24.5 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 TOTAL 0.135 0.247 0.108 0.085 0.581 0.396 0.061 0.038 0.047 0.034 0.022 0.004 0.031 0.022 0.024 0.114 1.950 TOTAL TOTAL TOTAL TOTAL HOURS HOURS HOURS HOURS OF VALID OBSERVATIONS OF GROUND LEVEL RELEASE OF STABILITY CLASS E OF GROUND LEVEL STABILITY CLASS E 2187.000 132.510 691.200 42.640 METEOROLOGICAL FACILITY:

BROWNS FERRY NUCLEAR PLANT STABILITY BASED ON DELTA-T BETWEEN 10.03 AND 45.30 METERS WIND DIRECTION MEASURED AT 10.50 METER LEVEL WIND SPEED MEASURED AT 10.50 METER LEVEL EFFLUENT VELOCITY = 12.60 M/S NOTE:

TOTALS AND SUBTOTALS ARE OBTAINED FROM UNROUNDED NUMBERS DATE PRINTED: 2013/11/15 E-118

BROWNS FERRY NUCLEAR PLANT UNITS 1, 2, AND 3 2013 ANNUAL RADIOACTIVE EFFLUENT RELEASE REPORT SPLIT JOINT PERCENTAGE FREQUENCIES OF WIND SPEED BY WIND DIRECTION FOR STABILITY CLASS F

( 1.5< DELTA T<= 4.0 C/100 M)

BROWNS FERRY NUCLEAR PLANT PART 1 OF 2 GROUND LEVEL RELEASE MODE JUL 1, 2013 -

SEP 30, 2013 WIND DIRECTION N

NNE NE ENE E

ESE SE SSE S

SSW SW WSW W

WNW NW NNW SUBTOTAL WIND SPEED(MPH) 0.6-1.4 1.5-3.4 3.5-5.4 5.5-7.4 CALM 7.5-12.4 12.5-18.4 18.5-24.4 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.002 0.004 0.002 0.004 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.012 0.160 0.048 0.005 0.055 0.081 0.005 0.011 0.000 0.000 0.000 0.000 0.000 0.003 0.000 0.002 0.017 0.385 0.093 0.091 0.022 0.059 0.047 0.006 0.000 0.000 0.000 0.000 0.000 0.000 0.001 0.000 0.000 0.005 0.325 0.000 0.032 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.032 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000

>=24.5 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 TOTAL 0.255 0.175 0.028 0.118 0.128 0.011 0.011 0.000 0.000 0.000 0.000 0.000 0.005 0.000 0.002 0.022 0.754 TOTAL TOTAL TOTAL TOTAL HOURS HOURS HOURS HOURS OF VALID OBSERVATIONS OF GROUND LEVEL RELEASE OF STABILITY CLASS F OF GROUND LEVEL STABILITY CLASS F 2187.000 132.510 283.200 16.500 METEOROLOGICAL FACILITY:

BROWNS FERRY NUCLEAR PLANT STABILITY BASED ON DELTA-T BETWEEN 10.03 AND 45.30 METERS WIND DIRECTION MEASURED AT 10.50 METER LEVEL WIND SPEED MEASURED AT 10.50 METER LEVEL EFFLUENT VELOCITY = 12.60 M/S NOTE:

TOTALS AND SUBTOTALS ARE OBTAINED FROM UNROUNDED NUMBERS DATE PRINTED: 2013/11/15 E-119

BROWNS FERRY NUCLEAR PLANT UNITS 1, 2, AND 3 2013 ANNUAL RADIOACTIVE EFFLUENT RELEASE REPORT SPLIT JOINT PERCENTAGE FREQUENCIES OF WIND SPEED BY WIND DIRECTION FOR STABILITY CLASS G (DELTA T > 4.0 C/100 M)

BROWNS FERRY NUCLEAR PLANT PART 1 OF 2 GROUND LEVEL RELEASE MODE JUL 1, 2013 -

SEP 30, 2013 WIND DIRECTION N

NNE NE ENE E

ESE SE SSE S

SSW SW WSW W

WNW NW NNW SUBTOTAL WIND SPEED(MPH) 0.6-1.4 1.5-3.4 3.5-5.4 5.5-7.4 CALM 7.5-12.4 12.5-18.4 18.5-24.4 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.002 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.002 0.037 0.033 0.008 0.016 0.006 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.002 0.103 0.013 0.014 0.000 0.007 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.034 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000

.0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000

>=24. 5 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 TOTAL 0.050 0.047 0.010 0.023 0.006 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.002 0.139 TOTAL TOTAL TOTAL TOTAL HOURS HOURS HOURS HOURS OF VALID OBSERVATIONS OF GROUND LEVEL RELEASE OF STABILITY CLASS G OF GROUND LEVEL STABILITY CLASS G 2187.000 132.510 41.750 3.030 METEOROLOGICAL FACILITY:

BROWNS FERRY NUCLEAR PLANT STABILITY BASED ON DELTA-T BETWEEN 10.03 AND 45.30 METERS WIND DIRECTION MEASURED AT 10.50 METER LEVEL WIND SPEED MEASURED AT 10.50 METER LEVEL EFFLUENT VELOCITY = 12.60 M/S NOTE:

TOTALS AND SUBTOTALS ARE OBTAINED FROM UNROUNDED NUMBERS DATE PRINTED: 2013/11/15 E-120

BROWNS FERRY NUCLEAR PLANT UNITS 1, 2, AND 3 2013 ANNUAL RADIOACTIVE EFFLUENT RELEASE REPORT SPLIT JOINT PERCENTAGE FREQUENCIES OF WIND SPEED BY WIND DIRECTION FOR STABILITY CLASS A (DELTA T<=-1.9 C/100 M)

BROWNS FERRY NUCLEAR PLANT PART 2 OF 2 ELEVATED RELEASE MODE JUL 1, 2013 -

SEP 30, 2013 WIND DIRECTION N

NNE NE ENE E

ESE SE SSE S

SSW SW WSW W

WNW NW NNW SUBTOTAL WIND SPEED(MPH) 0.6-1.4 1.5-3.4 3.5-5.4 5.5-7.4 CALM 7.5-12.4 12.5-18.4 18.5-24.4 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.132 0.087 0.044 0.000 0.000 0.000 0.000 0.000 0.000 0.263 0.000 0.000 0.000 0.000 0.000 0.000 0.079 0.000 0.041 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.120 0.038 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.038 0.000 0.000 0.000 0.076 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000

>=24.5 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 TOTAL 0.038 0.000 0.000 0.000 0.000 0.000 0.079 0.132 0.128 0.044 0.000 0.000 0.038 0.000 0.000 0.000 0.459 TOTAL HOURS OF VALID OBSERVATIONS TOTAL TOTAL TOTAL HOURS HOURS HOURS OF ELEVATED RELEASES OF STABILITY CLASS A OF ELEVATED STABILITY CLASS A 2187.000 2054.490 22.530 10.030 METEOROLOGICAL FACILITY:

BROWNS FERRY NUCLEAR PLANT STABILITY BASED ON DELTA-T BETWEEN 10.03 AND 89.59 METERS WIND DIRECTION MEASURED AT 45.74 METER LEVEL WIND SPEED MEASURED AT 45.74 METER LEVEL EFFLUENT VELOCITY = 12.60 M/S NOTE:

TOTALS AND SUBTOTALS ARE OBTAINED FROM UNROUNDED NUMBERS DATE PRINTED: 2013/11/15 E-121

BROWNS FERRY NUCLEAR PLANT UNITS 1, 2, AND 3 2013 ANNUAL RADIOACTIVE EFFLUENT RELEASE REPORT SPLIT JOINT PERCENTAGE FREQUENCIES OF WIND SPEED BY WIND DIRECTION FOR STABILITY CLASS B

(-1.9< DELTA T<=-1.7 C/100 M)

BROWNS FERRY NUCLEAR PLANT PART 2 OF 2 ELEVATED RELEASE MODE JUL 1, 2013 -

SEP 30, 2013 WIND DIRECTION N

NNE NE ENE E

ESE SE SSE S

SSW SW WSW W

WNW NW NNW SUBTOTAL WIND SPEED(MPH) 0.6-1.4 1.5-3.4 3.5-5.4 5.5-7.4 CALM 7.5-12.4 12.5-18.4 18.5-24.4 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.046 0.183 0.046 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.274 0.000 0.000 0.000 0.000 0.000 0.000 0.045 0.357 0.175 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.578 0.000 0.000 0.000 0.000 0.000 0.000 0.283 0.124 0.120 0.080 0.000 0.000 0.039 0.000 0.000 0.000 0.646 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.075 0.000 0.000 0.000 0.000 0.000 0.037 0.000 0.000 0.112 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000

>=24.5 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 TOTAL 0.000 0.000 0.000 0.000 0.000 0.000 0.374 0.739 0.341 0.080 0.000 0.000 0.039 0.037 0.000 0.000 1.609 TOTAL TOTAL TOTAL TOTAL HOURS HOURS HOURS HOURS OF VALID OBSERVATIONS OF ELEVATED RELEASES OF STABILITY CLASS B OF ELEVATED STABILITY CLASS B 2187.000 2054.490 43.100 35.190 METEOROLOGICAL FACILITY:

BROWNS FERRY NUCLEAR PLANT STABILITY BASED ON DELTA-T BETWEEN 10.03 AND 89.59 METERS WIND DIRECTION MEASURED AT 45.74 METER LEVEL WIND SPEED MEASURED AT 45.74 METER LEVEL EFFLUENT VELOCITY = 12.60 M/S NOTE:

TOTALS AND SUBTOTALS ARE OBTAINED FROM UNROUNDED NUMBERS DATE PRINTED: 2013/11/15 E-122

BROWNS FERRY NUCLEAR PLANT UNITS 1, 2, AND 3 2013 ANNUAL RADIOACTIVE EFFLUENT RELEASE REPORT SPLIT JOINT PERCENTAGE FREQUENCIES OF WIND SPEED BY WIND DIRECTION FOR STABILITY CLASS C

(-1.7< DELTA T<=-1.5 C/100 M)

BROWNS FERRY NUCLEAR PLANT PART 2 OF 2 ELEVATED RELEASE MODE JUL 1, 2013 -

SEP 30, 2013 WIND DIRECTION N

NNE NE ENE E

ESE SE SSE S

SSW SW WSW W

WNW NW NNW SUBTOTAL WIND SPEED(MPH) 0.6-1.4 1.5-3.4 3.5-5.4 5.5-7.4 CALM 7.5-12.4 12.5-18.4 18.5-24.4 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.046 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.046 0.091 0.000 0.000 0.000 0.000 0.000 0.412 0.137 0.229 0.091 0.046 0.183 0.091 0.000 0.000 0.000 1.280 0.045 0.045 0.000 0.000 0.000 0.000 0.175 0.045 0.135 0.000 0.087 0.091 0.262 0.046 0.000 0.000 0.931 0.200 0.235 0.080 0.000 0.000 0.000 0.648 0.165 0.081 0.000 0.000 0.000 0.166 0.081 0.201 0.158 2.015 0.000 0.000 0.037 0.000 0.000 0.000 0.113 0.000 0.000 0.000 0.000 0.000 0.000 0.038 0.038 0.000 0.226 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000

>=24.5 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 TOTAL 0.336 0.281 0.117 0.000 0.000 0.000 1.348 0.393 0.445 0.091 0.133 0.274 0.519 0.165 0.239 0.158 4.498 TOTAL TOTAL TOTAL TOTAL HOURS HOURS HOURS HOURS OF VALID OBSERVATIONS OF ELEVATED RELEASES OF STABILITY CLASS C OF ELEVATED STABILITY CLASS C 2187.000 2054.490 105.650 98.380 METEOROLOGICAL FACILITY:

BROWNS FERRY NUCLEAR PLANT STABILITY BASED ON DELTA-T BETWEEN 10.03 AND 89.59 METERS WIND DIRECTION MEASURED AT 45.74 METER LEVEL WIND SPEED MEASURED AT 45.74 METER LEVEL EFFLUENT VELOCITY = 12.60 M/S NOTE:

TOTALS AND SUBTOTALS ARE OBTAINED FROM UNROUNDED NUMBERS DATE PRINTED: 2013/11/15 E-123

BROWNS FERRY NUCLEAR PLANT UNITS 1, 2, AND 3 2013 ANNUAL RADIOACTIVE EFFLUENT RELEASE REPORT SPLIT JOINT PERCENTAGE FREQUENCIES OF WIND SPEED BY WIND DIRECTION FOR STABILITY CLASS D

(-1.5< DELTA T<=-0.5 C/100 M)

BROWNS FERRY NUCLEAR PLANT PART 2 OF 2 ELEVATED RELEASE MODE JUL 1, 2013 -

SEP 30, 2013 WIND DIRECTION WIND SPEED(MPH) 0.6-1.4 1.5-3.4 3.5-5.4 5.5-7.4 N

NNE NE ENE E

ESE SE SSE S

SSW SW WSW W

WNW NW NNW CALM 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.046 0.000 0.046 0.000 0.000 0.000 0.000 0.046 0.000 0.000 0.000 0.000 0.137 0.046 0.091 0.183 0.229 0.046 0.320 0.457 0.960 0.869 0.823 1.097 0.503 0.320 0.091 0.091 0.229 0.320 0.366 0.183 0.274 0.366 0.274 1.280 1.463 1.189 0.960 0.823 1.189 1.417

0. 412 0.274 0.274 0.622 0.439 0.310 0.180 0.310 0.787 1.240 1.005 1.111 0.444 0.355 0.574 1.193 0.356 0.437 0.355 7.5-12.4 12.5-18.4 18.5-24.4 1.249 1.001 0.286 0.000 0.408 1.902 1.888 2.409 0.844 0.571 0.084 0.163 0.404 0.854 0.726 0.648 0.188 0.227 0.000 0.000 0.038 0.000 1.450 0.602 0.187 0.000 0.000 0.000 0.038 0.075 0.000 0.000 2.805 0.000 0.000 0.000 0.000 0.000 0.000 0.239 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.239

>=24.5 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 TOTAL 2.425 2.125 0.962 0.683 1.213 3.283 6.600 6.439 4.199 2.798 2.359 2.474 3.372 1.787 1.528 1.506 SUBTOTAL 6.356 11.065 9.715 13.437 0.000 43.754 TOTAL HOURS OF VALID OBSERVATIONS TOTAL TOTAL TOTAL HOURS HOURS HOURS OF ELEVATED RELEASES OF STABILITY CLASS D OF ELEVATED STABILITY CLASS D 2187.000 2054.490 999.570 956.910 METEOROLOGICAL FACILITY:

BROWNS FERRY NUCLEAR PLANT STABILITY BASED ON DELTA-T BETWEEN 10.03 AND 89.59 METERS WIND DIRECTION MEASURED AT 45.74 METER LEVEL WIND SPEED MEASURED AT 45.74 METER LEVEL EFFLUENT VELOCITY = 12.60 M/S NOTE:

TOTALS AND SUBTOTALS ARE OBTAINED FROM UNROUNDED NUMBERS DATE PRINTED: 2013/11/15 E-1 24

BROWNS FERRY NUCLEAR PLANT UNITS 1, 2, AND 3 2013 ANNUAL RADIOACTIVE EFFLUENT RELEASE REPORT SPLIT JOINT PERCENTAGE FREQUENCIES OF WIND SPEED BY WIND DIRECTION FOR STABILITY CLASS E

(-0.5< DELTA T<= 1.5 C/100 M)

BROWNS FERRY NUCLEAR PLANT PART 2 OF 2 ELEVATED RELEASE MODE JUL 1, 2013 -

SEP 30, 2013 WIND DIRECTION WIND SPEED(MPH) 0.6-1.4 1.5-3.4 3.5-5.4 5.5-7.4 CALM 7.5-12.4 12.5-18.4 18.5-24.4 N

NNE NE ENE E

ESE SE SSE S

SSW SW WSW W

WNW NW NNW 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.046 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.046 0.046 0.000 0.000 0.000 0.046 0.000 0.000 0.183 0.137 0.091 0.229 0.137 0.229 0.091 0.229 0.503 0.412 0.366 0.366 0.320 0.091 0.229 0.091 0.046 3.567 0.274 0.412 0.320 0.229 0.274 0.457 0.640 1.052 0.869 0.686

0. 640 0.412 0.412 0.366 0.320 0.366 7.727 0.392 0.351 0.262 0.176 0.579 1.008 0.832 0.835 0.710 0.445 0.046 0.134 0.264 0.396 0.130 0.310 0.893 1.362 0.925 0.203
0. 621 2.504 1.728 1.051 0.449 0.081 0.042 0.000 0.041 0.000 0.163 0.284 0.000 0.226 0.000 0.000 0.000 0.038 0.340 0.186 0.037 0.000 0.000 0.000 0.037 0.038 0.037 0.000 0.940 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.020 0.000 0.020

>=24. 5 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 TOTAL 1.742 2.442 1.736 0.745 1.703 4.098 3.769 3.627 2.523 1.624 1.093 0.866 0.846 1.075 0.761 1.006 SUBTOTAL 6.873 10.346 0.000 29.655 TOTAL TOTAL TOTAL TOTAL HOURS HOURS HOURS HOURS OF VALID OBSERVATIONS OF ELEVATED RELEASES OF STABILITY CLASS E OF ELEVATED STABILITY CLASS E 2187.000 2054.490 691.200 648.560 METEOROLOGICAL FACILITY:

BROWNS FERRY NUCLEAR PLANT STABILITY BASED ON DELTA-T BETWEEN 10.03 AND 89.59 METERS WIND DIRECTION MEASURED AT 45.74 METER LEVEL WIND SPEED MEASURED AT 45.74 METER LEVEL EFFLUENT VELOCITY = 12.60 M/S NOTE:

TOTALS AND SUBTOTALS ARE OBTAINED FROM UNROUNDED NUMBERS DATE PRINTED: 2013/11/15 E-125

BROWNS FERRY NUCLEAR PLANT UNITS 1, 2, AND 3 2013 ANNUAL RADIOACTIVE EFFLUENT RELEASE REPORT SPLIT JOINT PERCENTAGE FREQUENCIES OF WIND SPEED BY WIND DIRECTION FOR STABILITY CLASS F

( 1.5< DELTA T<= 4.0 C/100 M)

BROWNS FERRY NUCLEAR PLANT PART 2 OF 2 ELEVATED RELEASE MODE JUL 1, 2013 -

SEP 30, 2013 WIND DIRECTION N

NNE NE ENE E

ESE SE SSE S

SSW SW WSW W

WNW NW NNW SUBTOTAL WIND SPEED(MPH) 0.6-1.4 1.5-3.4 3.5-5.4 5.5-7.4 CALM 7.5-12.4 12.5-18.4 18.5-24.4 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.046 0.000 0.000 0.046 0.046 0.046 0.046 0.000 0.000 0.091 0.000 0.000 0.046 0.000 0.000 0.366 0.091 0.000 0.091 0.183 0.091 0.046 0.229 0.183 0.457 0.183 0.274 0.000 0.091 0.046 0.183 0.000 2.149 0.137 0.046 0.274 0.046 0.137 0.229 0.229 0.320 0.274 0.091 0.046 0.000 0.091 0.046 0.229 0.091 2.286 0.134 0.353 0.482 0.311 0.131 0.262 0.573 0.089 0.000 0.000 0.000 0.000 0.090 0.045 0.090 0.090 2.649 0.803 1.393 0.861 0.283 0.363 0.371 0.326 0.000 0.042 0.000 0.000 0.000 0.038 0.000 0.000 0.000 4.480 0.000 0.189 0.076 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.265 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000

>=24.5 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 TOTAL 1.165 2.026 1.785 0.823 0.768 0.953 1.402 0.637 0.774 0.274 0.412 0.000 0.311 0.182 0.501 0.182 0.000 12.195 TOTAL TOTAL TOTAL TOTAL HOURS HOURS HOURS HOURS OF VALID OBSERVATIONS OF ELEVATED RELEASES OF STABILITY CLASS F OF ELEVATED STABILITY CLASS F

2187.000 2054.490 283.200 266.700 METEOROLOGICAL FACILITY:

BROWNS FERRY NUCLEAR PLANT STABILITY BASED ON DELTA-T BETWEEN 10.03 AND 89.59 METERS WIND DIRECTION MEASURED AT 45.74 METER LEVEL WIND SPEED MEASURED AT 45.74 METER LEVEL EFFLUENT VELOCITY = 12.60 M/S NOTE:

TOTALS AND SUBTOTALS ARE OBTAINED FROM UNROUNDED NUMBERS DATE PRINTED: 2013/11/15 E-126

BROWNS FERRY NUCLEAR PLANT UNITS 1, 2, AND 3 2013 ANNUAL RADIOACTIVE EFFLUENT RELEASE REPORT SPLIT JOINT PERCENTAGE FREQUENCIES OF WIND SPEED BY WIND DIRECTION FOR STABILITY CLASS G (DELTA T > 4.0 C/100 M)

BROWNS FERRY NUCLEAR PLANT PART 2 OF 2 ELEVATED RELEASE MODE JUL 1, 2013 -

SEP 30, 2013 WIND DIRECTION N

NNE NE ENE E

ESE SE SSE S

SSW SW WSW W

WNW NW NNW SUBTOTAL WIND SPEED(MPH) 0.6-1.4 1.5-3.4 3.5-5.4 5.5-7.4 CALM 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 7.5-12.4 12.5-18.4 18.5-24.4 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.046 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.046 0.137 0.000 0.046 0.046 0.046 0.000 0.137 0.046 0.046 0.046 0.046 0.046 0.046 0.046 0.000 0.000 0.732 0.000 0.046 0.000 0.000 0.091 0.046 0.137 0.000 0.046 0.000 0.000 0.000 0.000 0.000 0.000 0.046 0.412 0.000 0.045 0.000 0.044 0.046 0.044 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.179 0.000 0.079 0.040 0.205 0.078 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.402 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000

>=24.5 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 TOTAL 0.137 0.170 0.086 0.295 0.261 0.090 0.274 0.091 0.091 0.046 0.046 0.046 0.046 0.046 0.000 0.046 1.770 TOTAL TOTAL TOTAL TOTAL HOURS HOURS HOURS HOURS OF VALID OBSERVATIONS OF ELEVATED RELEASES OF STABILITY CLASS G OF ELEVATED STABILITY CLASS G 2187.000 2054.490 41.750 38.720 METEOROLOGICAL FACILITY:

BROWNS FERRY NUCLEAR PLANT STABILITY BASED ON DELTA-T BETWEEN 10.03 AND 89.59 METERS WIND DIRECTION MEASURED AT 45.74 METER LEVEL WIND SPEED MEASURED AT 45.74 METER LEVEL EFFLUENT VELOCITY = 12.60 M/S NOTE:

TOTALS AND SUBTOTALS ARE OBTAINED FROM UNROUNDED NUMBERS DATE PRINTED: 2013/11/15 E-127

BROWNS FERRY NUCLEAR PLANT UNITS 1, 2, AND 3 2013 ANNUAL RADIOACTIVE EFFLUENT RELEASE REPORT BROWNS FERRY NUCLEAR PLANT 2013 METEOROLOGICAL DATA TABLE 8D JOINT FREQUENCY DISTRIBUTION IN PERCENT FOR SPLIT LEVEL RELEASES (GROUND LEVEL RELEASE MODE AND ELEVATED RELEASE MODE)

FOURTH QUARTER E-128

BROWNS FERRY NUCLEAR PLANT UNITS 1, 2, AND 3 2013 ANNUAL RADIOACTIVE EFFLUENT RELEASE REPORT SPLIT JOINT PERCENTAGE FREQUENCIES OF WIND SPEED BY WIND DIRECTION FOR STABILITY CLASS A (DELTA T<=-1.9 C/100 M)

BROWNS FERRY NUCLEAR PLANT PART 1 OF 2 GROUND LEVEL RELEASE MODE OCT 1, 2013 -

DEC 31, 2013 WIND DIRECTION N

NNE NE ENE E

ESE SE SSE S

SSW SW WSW W

WNW NW NNW SUBTOTAL WIND SPEED(MPH) 0.6-1.4 1.5-3.4 3.5-5.4 5.5-7.4 CALM 7.5-12.4 12.5-18.4 18.5-24.4 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.029 0.067 0.067 0.006 0.000 0.000 0.000 0.000 0.000 0.000 0.170 0.000 0.000 0.000 0.000 0.000 0.022 0.015 0.027 0.003 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.067 0.000 0.007 0.005 0.000 0.000 0.008 0.058 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.078 0.006 0.046 0.016 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.024 0.000 0.092 0.104 0.000 0.009 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.113 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000

>=24.5 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 TOTAL 0.110 0.053 0.030 0.000 0.000 0.030 0.102 0.094 0.070 0.006 0.000 0.000 0.000 0.000 0.024 0.000 0.520 TOTAL TOTAL TOTAL TOTAL HOURS HOURS HOURS HOURS OF VALID OBSERVATIONS OF GROUND LEVEL RELEASE OF STABILITY CLASS A OF GROUND LEVEL STABILITY CLASS A 2204.000 232.440 24.630 11.450 METEOROLOGICAL FACILITY:

BROWNS FERRY NUCLEAR PLANT STABILITY BASED ON DELTA-T BETWEEN 10.03 AND 45.30 METERS WIND DIRECTION MEASURED AT 10.50 METER LEVEL WIND SPEED MEASURED AT 10.50 METER LEVEL EFFLUENT VELOCITY = 12.60 M/S NOTE:

TOTALS AND SUBTOTALS ARE OBTAINED FROM UNROUNDED NUMBERS DATE PRINTED: 2014/02/25 E-129

BROWNS FERRY NUCLEAR PLANT UNITS 1, 2, AND 3 2013 ANNUAL RADIOACTIVE EFFLUENT RELEASE REPORT SPLIT JOINT PERCENTAGE FREQUENCIES OF WIND SPEED BY WIND DIRECTION FOR STABILITY CLASS B

(-1.9< DELTA T<=-1.7 C/100 M)

BROWNS FERRY NUCLEAR PLANT PART 1 OF 2 GROUND LEVEL RELEASE MODE OCT 1, 2013 -

DEC 31, 2013 WIND DIRECTION N

NNE NE ENE E

ESE SE SSE S

SSW SW WSW W

WNW NW NNW SUBTOTAL WIND SPEED(MPH) 0.6-1.4 1.5-3.4 3.5-5.4 5.5-7.4 CALM 7.5-12.4 12.5-18.4 18.5-24.4 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.001 0.002 0.030 0.006 0.014 0.000 0.000 0.000 0.000 0.000 0.000 0.053 0.000 0.000 0.000 0.001 0.000 0.003 0.005 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.010 0.003 0.017 0.017 0.002 0.000 0.000 0.027 0.000 0.000 0.000 0.000 0.000 0.006 0.000 0.000 0.000 0.071 0.046 0.027 0.007 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.015 0.009 0.037 0.141 0.027 0.000 0.009 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.017 0.027 0.000 0.080 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000

>=24. 5 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 TOTAL 0.075 0.044 0.032 0.003 0.000 0.005 0.034 0.030 0.006 0.014 0.000 0.000 0.006 0.033 0.036 0.037 0.355 TOTAL TOTAL TOTAL TOTAL HOURS HOURS HOURS HOURS OF VALID OBSERVATIONS OF GROUND LEVEL RELEASE OF STABILITY CLASS B OF GROUND LEVEL STABILITY CLASS B 2204.000 232.440 23.920 7.820 METEOROLOGICAL FACILITY:

BROWNS FERRY NUCLEAR PLANT STABILITY BASED ON DELTA-T BETWEEN 10.03 AND 45.30 METERS WIND DIRECTION MEASURED AT 10.50 METER LEVEL WIND SPEED MEASURED AT 10.50 METER LEVEL EFFLUENT VELOCITY = 12.60 M/S NOTE:

TOTALS AND SUBTOTALS ARE OBTAINED FROM UNROUNDED NUMBERS DATE PRINTED: 2014/02/25 E-130

BROWNS FERRY NUCLEAR PLANT UNITS 1, 2, AND 3 2013 ANNUAL RADIOACTIVE EFFLUENT RELEASE REPORT SPLIT JOINT PERCENTAGE FREQUENCIES OF WIND SPEED BY WIND DIRECTION FOR STABILITY CLASS C

(-1.7< DELTA T<=-1.5 C/100 M)

BROWNS FERRY NUCLEAR PLANT PART 1 OF 2 GROUND LEVEL RELEASE MODE OCT 1, 2013 -

DEC 31, 2013 WIND DIRECTION N

NNE NE ENE E

ESE SE SSE S

SSW SW WSW W

WNW NW NNW SUBTOTAL WIND SPEED(MPH) 0.6-1.4 1.5-3.4 3.5-5.4 5.5-7.4 CALM 7.5-12.4 12.5-18.4 18.5-24.4 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.001 0.008 0.016 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.025 0.000 0.001 0.002 0.000 0.000 0.010 0.023 0.000 0.009 0.000 0.000 0.000 0.004 0.000 0.000 0.000 0.049 0.005 0.012 0.001 0.000 0.000 0.045 0.000 0.000 0.000 0.000 0.000 0.006 0.010 0.000 0.000 0.000 0.079 0.061 0.020 0.012 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.020 0.055 0.043 0.210 0.029 0.010 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.018 0.000 0.057 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000

>=24.5 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 TOTAL 0.094 0.042 0.016 0.000 0.000 0.055 0.024 0.008 0.025 0.000 0.000 0.007 0.013 0.020 0.073 0.043 0.421 TOTAL HOURS OF VALID OBSERVATIONS TOTAL TOTAL TOTAL HOURS HOURS HOURS OF GROUND LEVEL RELEASE OF STABILITY CLASS C OF GROUND LEVEL STABILITY CLASS C 2204.000 232.440 70.860 9.270 METEOROLOGICAL FACILITY:

BROWNS FERRY NUCLEAR PLANT STABILITY BASED ON DELTA-T BETWEEN 10.03 AND 45.30 METERS WIND DIRECTION MEASURED AT 10.50 METER LEVEL WIND SPEED MEASURED AT 10.50 METER LEVEL EFFLUENT VELOCITY = 12.60 M/S NOTE:

TOTALS AND SUBTOTALS ARE OBTAINED FROM UNROUNDED NUMBERS DATE PRINTED: 2014/02/25 E-1 31

BROWNS FERRY NUCLEAR PLANT UNITS 1, 2, AND 3 2013 ANNUAL RADIOACTIVE EFFLUENT RELEASE REPORT SPLIT JOINT PERCENTAGE FREQUENCIES OF WIND SPEED BY WIND DIRECTION FOR STABILITY CLASS D

(-1.5< DELTA T<=-0.5 C/100 M)

BROWNS FERRY NUCLEAR PLANT PART 1 OF 2 GROUND LEVEL RELEASE MODE OCT 1, 2013 -

DEC 31, 2013 WIND DIRECTION N

NNE NE ENE E

ESE SE SSE S

SSW SW WSW W

WNW NW NNW SUBTOTAL WIND SPEED (MPH) 0.6-1.4 1.5-3.4 3.5-5.4 5.5-7.4 CALM 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 7.5-12.4 12.5-18.4 18.5-24.4 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.006 0.059 0.102 0.034 0.080 0.089 0.004 0.000 0.002 0.000 0.000 0.000 0.376 0.018 0.016 0.007 0.003 0.043 0.143 0.060 0.000 0.016 0.000 0.008 0.014 0.036 0.004 0.010 0.020 0.399 0.123 0.092 0.040 0.019 0.022 0.156 0.019 0.000 0.043 0.081 0.000 0.000 0.047 0.033 0.048 0.100 0.823 0.374 0.192 0.020 0.000 0.000 0.019 0.000 0.000 0.000 0.000 0.000 0.000 0.016 0.114 0.273 0.322 1.329 0.061 0.017 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.009 0.191 0.173 0.451 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000

>=24.5 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 TOTAL 0.576 0.317

0. 067 0.022 0.071 0.377 0.181 0.034 0.139 0.170 0.011 0.015 0.101 0.160 0.521 0.615 3.377 TOTAL TOTAL TOTAL TOTAL HOURS HOURS HOURS HOURS OF VALID OBSERVATIONS OF GROUND LEVEL RELEASE OF STABILITY CLASS D OF GROUND LEVEL STABILITY CLASS D 2204.000 232.440 870.600 74.440 METEOROLOGICAL FACILITY:

BROWNS FERRY NUCLEAR PLANT STABILITY BASED ON DELTA-T BETWEEN 10.03 AND 45.30 METERS WIND DIRECTION MEASURED AT 10.50 METER LEVEL WIND SPEED MEASURED AT 10.50 METER LEVEL EFFLUENT VELOCITY = 12.60 M/S NOTE:

TOTALS AND SUBTOTALS ARE OBTAINED FROM UNROUNDED NUMBERS DATE PRINTED: 2014/02/25 E-132

BROWNS FERRY NUCLEAR PLANT UNITS 1, 2, AND 3 2013 ANNUAL RADIOACTIVE EFFLUENT RELEASE REPORT SPLIT JOINT PERCENTAGE FREQUENCIES OF WIND SPEED BY WIND DIRECTION FOR STABILITY CLASS E

(-0.5< DELTA T<= 1.5 C/100 M)

BROWNS FERRY NUCLEAR PLANT PART 1 OF 2 GROUND LEVEL RELEASE MODE OCT 1, 2013 -

DEC 31, 2013 WIND DIRECTION N

NNE NE ENE E

ESE SE SSE S

SSW SW WSW W

WNW NW NNW SUBTOTAL WIND SPEED(MPH) 0.6-1.4 1.5-3.4 3.5-5.4 5.5-7.4 CALM 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 7.5-12.4 12.5-18.4 18.5-24.4 0.000 0.000 0.000 0.007 0.002 0.006 0.013 0.013 0.016 0.000 0.004 0.000 0.000 0.000 0.008 0.000 0.069 0.031 0.011 0.001 0.008 0.083 0.125 0.164 0.182 0.186 0.062 0.021 0.024 0.007 0.000 0.004 0.005 0.914 0.064 0.082 0.012 0.028 0.069 0.266 0.137 0.000 0.103 0.019 0.000 0.016 0.054 0.014 0.034 0.075 0.973 0.085 0.056 0.096 0.010 0.006 0.075 0.010 0.000 0.127 0.019 0.000 0.007 0.031 0.000

0. 026 0.123 0.671 0.079 0.008 0.007 0.000 0.000 0.000 0.000 0.000 0.045 0.088 0.009 0.014 0.000 0.022 0.040 0.034 0.346 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.009 0.009 0.018 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000

>=24.5 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 TOTAL 0.259 0.157 0.116 0.054 0.160 0.472 0.324 0.195 0.476 0.188 0.034 0.061 0.093 0.036 0.121 0.246 2.991 TOTAL TOTAL TOTAL TOTAL HOURS HOURS HOURS HOURS OF VALID OBSERVATIONS OF GROUND LEVEL RELEASE OF STABILITY CLASS E OF GROUND LEVEL STABILITY CLASS E 2204.000 232.440 725.700 65.920 METEOROLOGICAL FACILITY:

BROWNS FERRY NUCLEAR PLANT STABILITY BASED ON DELTA-T BETWEEN 10.03 AND 45.30 METERS WIND DIRECTION MEASURED AT 10.50 METER LEVEL WIND SPEED MEASURED AT 10.50 METER LEVEL EFFLUENT VELOCITY = 12.60 M/S NOTE:

TOTALS AND SUBTOTALS ARE OBTAINED FROM UNROUNDED NUMBERS DATE PRINTED: 2014/02/25 E-133

BROWNS FERRY NUCLEAR PLANT UNITS 1, 2, AND 3 2013 ANNUAL RADIOACTIVE EFFLUENT RELEASE REPORT SPLIT JOINT PERCENTAGE FREQUENCIES OF WIND SPEED BY WIND DIRECTION FOR STABILITY CLASS F

( 1.5< DELTA T<= 4.0 C/100 M)

BROWNS FERRY NUCLEAR PLANT PART 1 OF 2 GROUND LEVEL RELEASE MODE OCT 1, 2013 -

DEC 31, 2013 WIND DIRECTION N

NNE NE ENE E

ESE SE SSE S

SSW SW WSW W

WNW NW NNW SUBTOTAL WIND SPEED(MPH) 0.6-1.4 1.5-3.4 3.5-5.4 5.5-7.4 CALM 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 7.5-12.4 12.5-18.4 18.5-24.4 0.000 0.000 0.000 0.004 0.013 0.000 0.027 0.022 0.029 0.000 0.000 0.000 0.000 0.000 0.000 0.001 0.096 0.094 0.027 0.025 0.054 0.114 0.075 0.072 0.111 0.223 0.013 0.000 0.000 0.000 0.000 0.007 0.048 0.864 0.105 0.042 0.015 0.026 0.044 0.028 0.016 0.044 0.148 0.009 0.000 0.000 0.000 0.000 0.000 0.086 0.563 0.039 0.015 0.000 0.000 0.000 0.000 0.000 0.000 0.128 0.000 0.000 0.000 0.000 0.000 0.000 0.039 0.222 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.045 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.045 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000

>=24. 5 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 TOTAL 0.238 0.084 0.041 0.084 0.171 0.103 0.115 0.177 0.574 0.022 0.000 0.000 0.000 0.000 0.007 0.175 1.791 TOTAL TOTAL TOTAL TOTAL HOURS HOURS HOURS HOURS OF VALID OBSERVATIONS OF GROUND LEVEL RELEASE OF STABILITY CLASS F OF GROUND LEVEL STABILITY CLASS F 2204.000 232.440 358.090 39.480 METEOROLOGICAL FACILITY:

BROWNS FERRY NUCLEAR PLANT STABILITY BASED ON DELTA-T BETWEEN 10.03 AND 45.30 METERS WIND DIRECTION MEASURED AT 10.50 METER LEVEL WIND SPEED MEASURED AT 10.50 METER LEVEL EFFLUENT VELOCITY = 12.60 M/S NOTE:

TOTALS AND SUBTOTALS ARE OBTAINED FROM UNROUNDED NUMBERS DATE PRINTED: 2014/02/25 E-1 34

BROWNS FERRY NUCLEAR PLANT UNITS 1, 2, AND 3 2013 ANNUAL RADIOACTIVE EFFLUENT RELEASE REPORT SPLIT JOINT PERCENTAGE FREQUENCIES OF WIND SPEED BY WIND DIRECTION FOR STABILITY CLASS G (DELTA T > 4.0 C/100 M)

BROWNS FERRY NUCLEAR PLANT PART 1 OF 2 GROUND LEVEL RELEASE MODE OCT 1, 2013 -

DEC 31, 2013 WIND DIRECTION N

NNE NE ENE E

ESE SE SSE S

SSW SW WSW W

WNW NW NNW SUBTOTAL WIND SPEED(MPH) 0.6-1.4 1.5-3.4 3.5-5.4 5.5-7.4 CALM 7.5-12.4 12.5-18.4 18.5-24.4 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.001 0.000 0.005 0.008 0.005 0.007 0.019 0.059 0.006 0.000 0.000 0.000 0.000 0.000 0.000 0.003 0.113 0.070 0.026 0.012 0.018 0.022 0.000 0.015 0.269 0.092 0.000 0.000 0.000 0.000 0.000 0.000 0.025 0.549 0.041 0.009 0.000 0.013 0.005 0.000 0.000 0.011 0.104 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.182 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.112 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.112 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.135 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.135 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000

>=24.5 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 TOTAL 0.112 0.035 0.017 0.039 0.031 0.008 0.034 0.339 0.449 0.000 0.000 0.000 0.000 0.000 0.000 0.027 1.092 TOTAL TOTAL TOTAL TOTAL HOURS HOURS HOURS HOURS OF VALID OBSERVATIONS OF GROUND LEVEL RELEASE OF STABILITY CLASS G OF GROUND LEVEL STABILITY CLASS G 2204.000 232.440 130.200 24.060 METEOROLOGICAL FACILITY:

BROWNS FERRY NUCLEAR PLANT STABILITY BASED ON DELTA-T BETWEEN 10.03 AND 45.30 METERS WIND DIRECTION MEASURED AT 10.50 METER LEVEL WIND SPEED MEASURED AT 10.50 METER LEVEL EFFLUENT VELOCITY = 12.60 M/S NOTE:

TOTALS AND SUBTOTALS ARE OBTAINED FROM UNROUNDED NUMBERS DATE PRINTED: 2014/02/25 E-135

BROWNS FERRY NUCLEAR PLANT UNITS 1, 2, AND 3 2013 ANNUAL RADIOACTIVE EFFLUENT RELEASE REPORT SPLIT JOINT PERCENTAGE FREQUENCIES OF WIND SPEED BY WIND DIRECTION FOR STABILITY CLASS A (DELTA T<=-1.9 C/100 M)

BROWNS FERRY NUCLEAR PLANT PART 2 OF 2 ELEVATED RELEASE MODE OCT 1, 2013 -

DEC 31, 2013 WIND DIRECTION N

NNE NE ENE E

ESE SE SSE S

SSW SW WSW W

WNW NW NNW SUBTOTAL WIND SPEED(MPH) 0.6-1.4 1.5-3.4 3.5-5.4 5.5-7.4 CALM 7.5-12.4 12.5-18.4 18.5-24.4 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.172 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.172 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.080 0.122 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.202 0.000 0.000 0.000 0.000 0.000 0.000 0.037 0.148 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.185 0.039 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.039

>=24.5 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 TOTAL 0.039 0.000 0.000 0.000 0.000 0.000 0.037 0.401 0.122 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.598 TOTAL HOURS OF VALID OBSERVATIONS TOTAL TOTAL TOTAL HOURS HOURS HOURS OF ELEVATED RELEASES OF STABILITY CLASS A OF ELEVATED STABILITY CLASS A 2204.000 1971.560 24.630 13.180 METEOROLOGICAL FACILITY:

BROWNS FERRY NUCLEAR PLANT STABILITY BASED ON DELTA-T BETWEEN 10.03 AND 89.59 METERS WIND DIRECTION MEASURED AT 45.74 METER LEVEL WIND SPEED MEASURED AT 45.74 METER LEVEL EFFLUENT VELOCITY = 12.60 M/S NOTE:

TOTALS AND SUBTOTALS ARE OBTAINED FROM UNROUNDED NUMBERS DATE PRINTED: 2014/02/25 E-1 36

BROWNS FERRY NUCLEAR PLANT UNITS 1, 2, AND 3 2013 ANNUAL RADIOACTIVE EFFLUENT RELEASE REPORT SPLIT JOINT PERCENTAGE FREQUENCIES OF WIND SPEED BY WIND DIRECTION FOR STABILITY CLASS B

(-1.9< DELTA T<=-1.7 C/100 M)

BROWNS FERRY NUCLEAR PLANT PART 2 OF 2 ELEVATED RELEASE MODE OCT 1, 2013 -

DEC 31, 2013 WIND DIRECTION N

NNE NE ENE E

ESE SE SSE S

SSW SW WSW W

WNW NW NNW SUBTOTAL WIND SPEED(MPH) 0.6-1.4 1.5-3.4 3.5-5.4 5.5-7.4 CALM 7.5-12.4 12.5-18.4 18.5-24.4 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.045 0.000 0.045 0.000 0.000 0.000 0.000 0.000 0.091 0.000 0.000 0.000 0.000 0.000 0.000 0.045 0.044 0.044 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.132 0.000 0.038 0.000 0.000 0.000 0.000 0.000 0.079 0.197 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.314 0.000 0.000 0.000 0.000 0.000 0.000 0.110 0.037 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.147 0.025 0.000 0.000 0.000 0.000 0.000 0.021 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.046

>=24.5 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 TOTAL 0.025 0.038 0.000 0.000 0.000 0.000 0.177 0.160 0.286 0.000 0.045 0.000 0.000 0.000 0.000 0.000 0.730 TOTAL TOTAL TOTAL TOTAL HOURS HOURS HOURS HOURS OF VALID OBSERVATIONS OF ELEVATED RELEASES OF STABILITY CLASS B OF ELEVATED STABILITY CLASS B 2204.000 1971.560 23.920 16.100 METEOROLOGICAL FACILITY:

BROWNS FERRY NUCLEAR PLANT STABILITY BASED ON DELTA-T BETWEEN 10.03 AND 89.59 METERS WIND DIRECTION MEASURED AT 45.74 METER LEVEL WIND SPEED MEASURED AT 45.74 METER LEVEL EFFLUENT VELOCITY = 12.60 M/S NOTE:

TOTALS AND SUBTOTALS ARE OBTAINED FROM UNROUNDED NUMBERS DATE PRINTED: 2014/02/25 E-137

BROWNS FERRY NUCLEAR PLANT UNITS 1, 2, AND 3 2013 ANNUAL RADIOACTIVE EFFLUENT RELEASE REPORT SPLIT JOINT PERCENTAGE FREQUENCIES OF WIND SPEED BY WIND DIRECTION FOR STABILITY CLASS C

(-1.7< DELTA T<=-1.5 C/100 M)

BROWNS FERRY NUCLEAR PLANT PART 2 OF 2 ELEVATED RELEASE MODE OCT 1, 2013 -

DEC 31, 2013 WIND DIRECTION N

NNE NE ENE E

ESE SE SSE S

SSW SW WSW W

WNW NW NNW SUBTOTAL WIND SPEED(MPH) 0.6-1.4 1.5-3.4 3.5-5.4 5.5-7.4 CALM 7.5-12.4 12.5-18.4 18.5-24.4 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.136 0.000 0.272 0.000 0.136 0.000 0.000 0.000 0.000 0.000 0.544 0.043 0.084 0.000 0.000 0.000 0.000 0.131 0.088 0.088 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.433 0.351 0.202 0.039 0.000 0.000 0.000 0.118 0.042 0.039 0.000 0.000 0.040 0.080 0.038 0.000 0.000 0.949 0.038 0.298 0.037 0.000 0.000 0.000 0.112 0.000 0.000 0.000 0.000 0.000 0.000 0.111 0.221 0.037 0.853 0.015 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.015

>=24.5 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 TOTAL 0.446 0.585 0.075 0.000 0.000 0.000 0.497 0.129 0.399 0.000 0.136 0.040 0.080 0.149 0.221 0.037 2.794 TOTAL HOURS OF VALID OBSERVATIONS TOTAL TOTAL TOTAL HOURS HOURS HOURS OF ELEVATED RELEASES OF STABILITY CLASS C OF ELEVATED STABILITY CLASS C 2204.000 1971.560 70.860 61.590 METEOROLOGICAL FACILITY:

BROWNS FERRY NUCLEAR PLANT STABILITY BASED ON DELTA-T BETWEEN 10.03 AND 89.59 METERS WIND DIRECTION MEASURED AT 45.74 METER LEVEL WIND SPEED MEASURED AT 45.74 METER LEVEL EFFLUENT VELOCITY = 12.60 M/S NOTE:

TOTALS AND SUBTOTALS ARE OBTAINED FROM UNROUNDED NUMBERS DATE PRINTED: 2014/02/25 E-138

BROWNS FERRY NUCLEAR PLANT UNITS 1, 2, AND 3 2013 ANNUAL RADIOACTIVE EFFLUENT RELEASE REPORT SPLIT JOINT PERCENTAGE FREQUENCIES OF WIND SPEED BY WIND DIRECTION FOR STABILITY CLASS D

(-1.5< DELTA T<=-0.5 C/100 M)

BROWNS FERRY NUCLEAR PLANT PART 2 OF 2 ELEVATED RELEASE MODE OCT 1, 2013 -

DEC 31, 2013 WIND DIRECTION WIND SPEED(MPH) 0.6-1.4 1.5-3.4 3.5-5.4 5.5-7.4 CALM 7.5-12.4 12.5-18.4 18.5-24.4 N

NNE NE ENE E

ESE SE SSE S

SSW SW WSW W

WNW NW NNW 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.045 0.000 0.000 0.045 0.000 0.000 0.091 0.000 0.000 0.045 0.000 0.000 0.227 0.091 0.045 0.091 0.045 0.045 0.136 0.227 0.771 0.363 0.318 0.318 0.272 0.000 0.181 0.045 0.000 2.949 0.363 0.590 0.091 0.181 0.227 0.272 1.089 0.544 0.408 0.454 0.544 0.318 0.681 0.227 0.136 0.318 6.443 0.349 0.921 0.523 0.216 0.265 0.219 0.520 0.438 0.433 0.265 0.353 0.131 0.790 0.303 0.443 0.392 1.381 1.469 0.611 0.082 0.326 0.568 0.677 0.794 0.634 0.399 0.040 0.201 0.559 0.796 1.113 1.455 2.100 0.553 0.038 0.000 0.000 0.075 1.138 0.558 0.481 0.113 0.038 0.000 0.037 0.335 1.248 0.961 7.675 0.275 0.120 0.000 0.000 0.000 0.000 0.316 0.000 0.033 0.000 0.000 0.000 0.000 0.000 0.158 0.248 1.151

>=24.5 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.012 0.003 0.000 0.000 0.000 0.000 0.000 0.000 TOTAL 4.559 3.698 1.353 0.525 0.908 1.270 3.966 3.151 2.365 1.550 1.383 0.922 2.066 1.888 3.144 3.374 SUBTOTAL 6.561 11.103 0.015 36.123 TOTAL TOTAL TOTAL TOTAL HOURS HOURS HOURS HOURS OF VALID OBSERVATIONS OF ELEVATED RELEASES OF STABILITY CLASS D OF ELEVATED STABILITY CLASS D 2204.000 1971.560 870.600 796.160 METEOROLOGICAL FACILITY:

BROWNS FERRY NUCLEAR PLANT STABILITY BASED ON DELTA-T BETWEEN 10.03 AND 89.59 METERS WIND DIRECTION MEASURED AT 45.74 METER LEVEL WIND SPEED MEASURED AT 45.74 METER LEVEL EFFLUENT VELOCITY = 12.60 M/S NOTE:

TOTALS AND SUBTOTALS ARE OBTAINED FROM UNROUNDED NUMBERS DATE PRINTED: 2014/02/25 E-139

BROWNS FERRY NUCLEAR PLANT UNITS 1, 2, AND 3 2013 ANNUAL RADIOACTIVE EFFLUENT RELEASE REPORT SPLIT JOINT PERCENTAGE FREQUENCIES OF WIND SPEED BY WIND DIRECTION FOR STABILITY CLASS E

(-0.5< DELTA T<= 1.5 C/100 M)

BROWNS FERRY NUCLEAR PLANT PART 2 OF 2 ELEVATED RELEASE MODE OCT 1, 2013 -

DEC 31, 2013 WIND DIRECTION WIND SPEED(MPH) 0.6-1.4 1.5-3.4 3.5-5.4 5.5-7.4 CALM 7.5-12.4 12.5-18.4 18.5-24.4 N

NNE NE ENE E

ESE SE SSE S

SSW SW WSW W

WNW NW NNW 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.091 0.000 0.000 0.000 0.000 0.045 0.000 0.000 0.000 0.000 0.000 0.045 0.000 0.181 0.045 0.136 0.136 0.181 0.363 0.045 0.363 0.136 0.181 0.136 0.318 0.136 0.045 0.045 0.000 0.000 2.269 0.227 0.227 0.136 0.091 0.272 0.227 0.544 0.499 0.272 0.227 0.227 0.181 0.136 0.136 0.091 0.227 3.721 0.437 0.431 0.218 0.043 0.433 0.569 0.608 0.744 0.476 0.264 0.445 0.221 0.221 0.218 0.044 0.170 1.045 1.069 0.795 0.240 0.403 0.964 1.983 1.423 0.999 0.720 0.240 0.078 0.364 0.245 0.358 1.381 0.746 0.188

0. 038 0.000 0.000 0.075 0.847 1.664 0.740 0.404 0.037 0.037 0.000 0.112 0.112 0.299 5.299 0.000 0.000 0.000 0.000 0.000 0.000 0.093 0.187 0.158 0.127 0.000 0.032 0.000 0.000 0.000 0.000 0.598

>=24. 5 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.020 0.000 0.000 0.000 0.000 0.000 0.000 0.000 TOTAL 2.500 2.052 1.323 0.647 1.471 1.880 4.438 4.653 2.892 1.877 1.266 0.685 0.766 0.757 0.650 2.077 SUBTOTAL 5.540 12.308 0.020 29.936 TOTAL TOTAL TOTAL TOTAL HOURS HOURS HOURS HOURS OF VALID OBSERVATIONS OF ELEVATED RELEASES OF STABILITY CLASS E OF ELEVATED STABILITY CLASS E 2204.000 1971.560 725.700 659.780 METEOROLOGICAL FACILITY:

BROWNS FERRY NUCLEAR PLANT STABILITY BASED ON DELTA-T BETWEEN 10.03 AND 89.59 METERS WIND DIRECTION MEASURED AT 45.74 METER LEVEL WIND SPEED MEASURED AT 45.74 METER LEVEL EFFLUENT VELOCITY = 12.60 M/S NOTE:

TOTALS AND SUBTOTALS ARE OBTAINED FROM UNROUNDED NUMBERS DATE PRINTED: 2014/02/25 E-140

BROWNS FERRY NUCLEAR PLANT UNITS 1, 2, AND 3 2013 ANNUAL RADIOACTIVE EFFLUENT RELEASE REPORT SPLIT JOINT PERCENTAGE FREQUENCIES OF WIND SPEED BY WIND DIRECTION FOR STABILITY CLASS F

( 1.5< DELTA T<= 4.0 C/100 M)

BROWNS FERRY NUCLEAR PLANT PART 2 OF 2 ELEVATED RELEASE MODE OCT 1, 2013 -

DEC 31, 2013 WIND DIRECTION N

NNE NE ENE E

ESE SE SSE S

SSW SW WSW W

WNW NW NNW SUBTOTAL WIND SPEED(MPH) 0.6-1.4 1.5-3.4 3.5-5.4 5.5-7.4 CALM 7.5-12.4 12.5-18.4 18.5-24.4 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.045 0.045 0.000 0.045 0.045 0.000 0.091 0.000 0.045 0.000 0.000 0.318 0.227 0.136 0.136 0.136 0.045 0.227 0.272 0.091 0.136 0.091 0.045 0.091 0.045 0.045 0.091 0.136 1.951 0.136 0.091 0.091 0.091 0.227 0.499 0.635 0.181 0.091 0.091 0.091 0.045 0.000 0.045 0.045 0.136 2.495 0.260 0.262 0.305 0.304 0.304 0.565 0.831 0.304 0.088 0.045 0.000 0.087 0.000 0.044 0.042 0.130 3.571 0.480 0.876 0.207 0.240 0.160 0.365 0.841

0. 352 0.440 0.077 0.000 0.000 0.000 0.000 0.000 0.159 4.197 0.000 0.113 0.000 0.000 0.000 0.038 0.038 0.551 0.556 0.038 0.000 0.000 0.000 0.000 0.000 0.150 1.482 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.238 0.193 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.431

>=24.5 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.011 0.000 0.000 0.000 0.000 0.000 0.000 0.000 TOTAL 1.103 1.478 0.740 0.770 0.736 1.740 2.662 1.716 1.559 0.387 0.136 0.314 0.045 0.180 0.178 0.711 0.011 14.456 TOTAL TOTAL TOTAL TOTAL HOURS HOURS HOURS HOURS OF VALID OBSERVATIONS OF ELEVATED RELEASES OF STABILITY CLASS F OF ELEVATED STABILITY CLASS F

2204.000 1971.560 358.090 318.610 METEOROLOGICAL FACILITY:

BROWNS FERRY NUCLEAR PLANT STABILITY BASED ON DELTA-T BETWEEN 10.03 AND 89.59 METERS WIND DIRECTION MEASURED AT 45.74 METER LEVEL WIND SPEED MEASURED AT 45.74 METER LEVEL EFFLUENT VELOCITY = 12.60 M/S NOTE:

TOTALS AND SUBTOTALS ARE OBTAINED FROM UNROUNDED NUMBERS DATE PRINTED: 2014/02/25 E-141

BROWNS FERRY NUCLEAR PLANT UNITS 1, 2, AND 3 2013 ANNUAL RADIOACTIVE EFFLUENT RELEASE REPORT SPLIT JOINT PERCENTAGE FREQUENCIES OF WIND SPEED BY WIND DIRECTION FOR STABILITY CLASS G (DELTA T > 4.0 C/100 M)

BROWNS FERRY NUCLEAR PLANT PART 2 OF 2 ELEVATED RELEASE MODE OCT 1, 2013 -

DEC 31, 2013 WIND DIRECTION N

NNE NE ENE E

ESE SE SSE S

SSW SW WSW W

WNW NW NNW SUBTOTAL WIND SPEED(MPH) 0.6-1.4 1.5-3.4 3.5-5.4 5.5-7.4 CALM 7.5-12.4 12.5-18.4 18.5-24.4 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.045 0.000 0.000 0.000 0.000 0.000 0.045 0.000 0.000 0.000 0.000 0.045 0.000 0.136 0.091 0.091 0.181 0.136 0.272 0.136 0.363 0.136 0.045 0.181 0.045 0.045 0.136 0.000 0.045 0.000 1.906 0.045 0.136 0.181 0.045 0.045 0.272 0.363 0.091 0.000 0.000 0.000 0.000 0.136 0.000 0.000 0.091 1.407 0.000 0.133 0.171 0.000 0.045 0.091 0.131 0.043 0.044 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.657 0.157 0.164 0.082 0.121 0.000 0.039 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.564 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.110 0.037 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.147 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000

>=24.5 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 TOTAL 0.293 0.524 0.616 0.348 0.363 0.539 0.857 0.379 0.127 0.227 0.045 0.045 0.272 0.000 0.091 0.091 4.816 TOTAL TOTAL TOTAL TOTAL HOURS HOURS HOURS HOURS OF VALID OBSERVATIONS OF ELEVATED RELEASES OF STABILITY CLASS G OF ELEVATED STABILITY CLASS G 2204.000 1971.560 130.200 106.140 METEOROLOGICAL FACILITY:

BROWNS FERRY NUCLEAR PLANT STABILITY BASED ON DELTA-T BETWEEN 10.03 AND 89.59 METERS WIND DIRECTION MEASURED AT 45.74 METER LEVEL WIND SPEED MEASURED AT 45.74 METER LEVEL EFFLUENT VELOCITY = 12.60 M/S NOTE:

TOTALS AND SUBTOTALS ARE OBTAINED FROM UNROUNDED NUMBERS DATE PRINTED: 2014/02/25 E-142

BROWNS FERRY NUCLEAR PLANT UNITS 1, 2, AND 3 2013 ANNUAL RADIOACTIVE EFFLUENT RELEASE REPORT BROWNS FERRY NUCLEAR PLANT 2013 METEOROLOGICAL DATA TABLE 9A JOINT FREQUENCY DISTRIBUTION IN PERCENT FOR ELEVATED RELEASES FIRST QUARTER E-143

BROWNS FERRY NUCLEAR PLANT UNITS 1, 2, AND 3 2013 ANNUAL RADIOACTIVE EFFLUENT RELEASE REPORT JOINT PERCENTAGE FREQUENCIES OF WIND SPEED BY WIND DIRECTION FOR STABILITY CLASS A (DELTA T<=-1.9 C/100 M)

BROWNS FERRY NUCLEAR PLANT JAN 1, 2013 -

MAR 31, 2013 WIND DIRECTION N

NNE NE ENE E

ESE SE SSE S

SSW SW WSW W

WNW NW NNW SUBTOTAL WIND SPEED(MPH) 0.6-1.4 1.5-3.4 3.5-5.4 5.5-7.4 7.5-12.4 12.5-18.4 18.5-24.4 CALM 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000

>=24.5 TOTAL 0.000 0.000 0.000O 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.047 0.000 0.000 0.000 0.000 0.000 0.000 0.047 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.047 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.047 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.047 0.000 0.000 0.047 0.000 0.000 0.000 0.000 0.000 0.000 0.093 TOTAL HOURS OF VALID STABILITY OBSERVATIONS TOTAL HOURS OF STABILITY CLASS A TOTAL TOTAL TOTAL HOURS HOURS HOURS OF VALID WIND DIRECTION-WIND SPEED-STABILITY CLASS A OF VALID WIND DIRECTION-WIND SPEED-STABILITY OBSERVATIONS CALM 2141 2

2 2141 0

METEOROLOGICAL FACILITY:

BROWNS FERRY NUCLEAR PLANT STABILITY BASED ON DELTA-T BETWEEN 10.03 AND 89.59 METERS WIND SPEED AND DIRECTION MEASURED AT 90.29 METER LEVEL DATE PRINTED: 2013/05/22 MEAN WIND SPEED = 10.25 NOTE:

TOTALS AND SUBTOTALS ARE OBTAINED FROM UNROUNDED NUMBERS E-144

BROWNS FERRY NUCLEAR PLANT UNITS 1, 2, AND 3 2013 ANNUAL RADIOACTIVE EFFLUENT RELEASE REPORT JOINT PERCENTAGE FREQUENCIES OF WIND SPEED BY WIND DIRECTION FOR STABILITY CLASS B

(-1.9< DELTA T<=-1.7 C/100 M)

BROWNS FERRY NUCLEAR PLANT JAN 1, 2013 -

MAR 31, 2013 WIND DIRECTION N

NNE NE ENE E

ESE SE SSE S

SSW SW WSW W

WNW NW NNW SUBTOTAL WIND SPEED(MPH) 0.6-1.4 1.5-3.4 3.5-5.4 5.5-7.4 7.5-12.4 12.5-18.4 CALM 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 18.5-24.4

>=24.5 TOTAL 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.093 0.047 0.000 0.047 0.047 0.047 0.000 0.000 0.000 0.000 0.280 0.000 0.000 0.000 0.000 0.000 0.047 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.047 0.000 0.047 0.000 0.000 0.000 0.047 0.047 0.000 0.000 0.047 0.047 0.047 0.000 0.000 0.000 0.000 0.280 0.000 0.000 0.000 0.000 0.000 0.000 0.047 0.000 0.000 0.093 0.000 0.000 0.000 0.047 0.000 0.000 0.187 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.140 0.000 0.000 0.140 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.047 0.000 0.000 0.000 0.093 0.187 0.047 0.000 0.187 0.093 0.093 0.000 0.187 0.000 0.000 0.934 TOTAL HOURS OF VALID STABILITY OBSERVATIONS TOTAL HOURS OF STABILITY CLASS B TOTAL TOTAL TOTAL HOURS HOURS HOURS OF VALID WIND DIRECTION-WIND SPEED-STABILITY CLASS B OF VALID WIND DIRECTION-WIND SPEED-STABILITY OBSERVATIONS CALM 2141 20 20 2141 0

METEOROLOGICAL FACILITY:

BROWNS FERRY NUCLEAR PLANT STABILITY BASED ON DELTA-T BETWEEN 10.03 AND 89.59 METERS WIND SPEED AND DIRECTION MEASURED AT 90.29 METER LEVEL DATE PRINTED: 2013/05/22 MEAN WIND SPEED = 11.07 NOTE:

TOTALS AND SUBTOTALS ARE OBTAINED FROM UNROUNDED NUMBERS E-145

BROWNS FERRY NUCLEAR PLANT UNITS 1, 2, AND 3 2013 ANNUAL RADIOACTIVE EFFLUENT RELEASE REPORT JOINT PERCENTAGE FREQUENCIES OF WIND SPEED BY WIND DIRECTION FOR STABILITY CLASS C

(-1.7< DELTA T<=-1.5 C/100 M)

BROWNS FERRY NUCLEAR PLANT JAN 1, 2013 -

MAR 31, 2013 WIND DIRECTION N

NNE NE ENE E

ESE SE SSE S

SSW SW WSW W

WNW NW NNW SUBTOTAL WIND SPEED(MPH) 0.6-1.4 1.5-3.4 3.5-5.4 5.5-7.4 7.5-12.4 12.5-18.4 18.5-24.4 CALM 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000

>=24.5 TOTAL 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.047 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.047 0.000 0.000 0.000 0.000 0.000 0.047 0.000 0.093 0.280 0.093 0.000 0.000 0.000 0.000 0.000 0.000 0.514 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.047 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.047 0.093 0.140 0.000 0.000 0.047 0.000 0.187 0.093 0.047 0.000 0.047 0.140 0.093 0.047 0.000 0.000 0.934 0.234 0.000 0.000 0.000 0.000 0.093 0.093 0.000 0.047 0.047 0.000 0.000 0.140 0.234 0.047 0.093 1.028 0.047 0.000 0.000 0.000 0.000 0.047 0.000 0.000 0.000 0.000 0.047 0.047 0.000 0.280 0.047 0.000 0.514 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.047 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.047 0.374 0.140 0.000 0.000 0.047 0.187 0.327 0.234 0.420 0.140 0.093 0.187 0.234

0. 560 0.093 0.093 3.129 TOTAL HOURS OF VALID STABILITY OBSERVATIONS TOTAL HOURS OF STABILITY CLASS C TOTAL TOTAL TOTAL HOURS HOURS HOURS OF VALID WIND DIRECTION-WIND SPEED-STABILITY CLASS C OF VALID WIND DIRECTION-WIND SPEED-STABILITY OBSERVATIONS CALM 2141 67 67 2141 0

METEOROLOGICAL FACILITY:

BROWNS FERRY NUCLEAR PLANT STABILITY BASED ON DELTA-T BETWEEN 10.03 AND 89.59 METERS WIND SPEED AND DIRECTION MEASURED AT 90.29 METER LEVEL MEAN WIND SPEED = 12.67 NOTE:

TOTALS AND SUBTOTALS ARE OBTAINED FROM UNROUNDED NUMBERS DATE PRINTED: 2013/05/22 E-146

BROWNS FERRY NUCLEAR PLANT UNITS 1, 2, AND 3 2013 ANNUAL RADIOACTIVE EFFLUENT RELEASE REPORT JOINT PERCENTAGE FREQUENCIES OF WIND SPEED BY WIND DIRECTION FOR STABILITY CLASS D

(-1.5< DELTA T<=-0.5 C/100 M)

BROWNS FERRY NUCLEAR PLANT JAN 1, 2013 -

MAR 31, 2013 WIND DIRECTION N

NNE NE ENE E

ESE SE SSE S

SSW SW WSW W

WNW NW NNW SUBTOTAL WIND SPEED(MPH) 0.6-1.4 1.5-3.4 3.5-5.4 5.5-7.4 7.5-12.4 12.5-18.4 18.5-24.4 CALM 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000

>=24.5 TOTAL 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.047 0.000 0.093 0.047 0.047 0.000 0.140 0.047 0.140 0.234 0.327 0.280 0.000 0.093 0.000 0.000 1.495 0.140 0.420 0.234 0.140 0.140 0.093 0.093 0.234 0.140 0.187 0.374 0.467 0.280 0.234 0.140 0.140 3.456 0.607 0.560 0.280 0.327 0.187 0.374 0.327 0.140 0.140 0.280 0.280 0.234 0.514 0.607 0.280 0.280 1.962 1.775 1.028 0.701 0.981 1.028 0.420 0.327 0.047 0.187 0.467 0.607 1.121 1.728 1.448 1.588 1.868 0.514 0.093 0.093 0.234 0.934 0.747 0.187 0.187 0.280 0.374 1.028 1.168 1.775 3.176 0.747 0.280 0.093 0.000 0.000 0.000 0.327 0.327 0.234 0.187 0.140 0.234 0.187 0.420 1.308 1.401 0.374 5.511 0.000 0.000 0.000 0.000 0.000 0.093 0.560 0.000 0.093 0.000 0.000 0.000 0.420 0.981 0.560 0.234 4.904 3.363 1.728 1.308 1.588 2.849 2.616 1.168 0.934 1.308 2.055 2.802 3.923 6.726 7.006 3.363 5.418 15.413 13.405 2.943 47.641 TOTAL HOURS OF VALID STABILITY OBSERVATIONS TOTAL HOURS OF STABILITY CLASS D TOTAL TOTAL TOTAL HOURS HOURS HOURS OF VALID WIND DIRECTION-WIND SPEED-STABILITY CLASS D OF VALID WIND DIRECTION-WIND SPEED-STABILITY OBSERVATIONS CALM 2141 1020 1020 2141 0

METEOROLOGICAL FACILITY:

BROWNS FERRY NUCLEAR PLANT STABILITY BASED ON DELTA-T BETWEEN 10.03 AND 89.59 METERS WIND SPEED AND DIRECTION MEASURED AT 90.29 METER LEVEL DATE PRINTED: 2013/05/22 MEAN WIND SPEED = 12.78 NOTE:

TOTALS AND SUBTOTALS ARE OBTAINED FROM UNROUNDED NUMBERS E-147

BROWNS FERRY NUCLEAR PLANT UNITS 1, 2, AND 3 2013 ANNUAL RADIOACTIVE EFFLUENT RELEASE REPORT JOINT PERCENTAGE FREQUENCIES OF WIND SPEED BY WIND DIRECTION FOR STABILITY CLASS E

(-0.5< DELTA T<= 1.5 C/100 M)

BROWNS FERRY NUCLEAR PLANT JAN 1, 2013 -

MAR 31, 2013 WIND DIRECTION N

NNE NE ENE E

ESE SE SSE S

SSW SW WSW W

WNW NW NNW SUBTOTAL WIND SPEED(MPH) 0.6-1.4 1.5-3.4 3.5-5.4 5.5-7.4 7.5-12.4 12.5-18.4 CALM 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 18.5-24.4

>=24.5 TOTAL 0.000 0.000 0.047 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.047 0.000 0.000 0.093 0.000 0.000 0.047 0.187 0.140 0.000 0.093 0.000 0.000 0.047 0.000 0.000 0.047 0.000 0.047 0.047 0.654 0.000 0.047 0.047 0.234 0.327 0.093 0.140 0.093 0.093 0.047 0.093 0.140 0.047 0.140 0.047 0.093 1.681 0.047 0.140 0.234 0.187 0.187 0.093 0.140 0.047 0.234 0.047 0.047 0.280 0.327 0.374 0.093 0.140 1.074 1.308 0.841 0.374 0.327 0.607 0.607 0.747 0.560 0.560 1.028 1.214 0.467 0.327 0.514 0.374 1.168 1.121

0. 934 0.654 0.280 0.794 1.775 0.981 1.541 0.701 1.214 0.234 0.140 0.047 0.841 1.775 0.000 0.047 0.047 0.093 0.047 0.140 1.121 0.560 0.981 0.327 0.000 0.000 0.047 0.047 0.140 0.187 3.783 0.000 0.000 0.000 0.000 0.000 0.000 0.467 0.514 0.747 0.187 0.000 0.000 0.093 0.093 0.000 0.000 2.289 2.662 2.195 1.728 1.308 1.728 4.344 2.943 4.157 1.915 2.382 1.868 1.168 1.074 1.681 2.616 2.616 10.929 14.199 2.102 36.058 TOTAL HOURS OF VALID STABILITY OBSERVATIONS TOTAL HOURS OF STABILITY CLASS E TOTAL TOTAL TOTAL HOURS HOURS HOURS OF VALID WIND DIRECTION-WIND SPEED-STABILITY CLASS E OF VALID WIND DIRECTION-WIND SPEED-STABILITY OBSERVATIONS CALM 2141 772 772 2141 0

METEOROLOGICAL FACILITY:

BROWNS FERRY NUCLEAR PLANT STABILITY BASED ON DELTA-T BETWEEN 10.03 AND 89.59 METERS WIND SPEED AND DIRECTION MEASURED AT 90.29 METER LEVEL MEAN WIND SPEED = 13.65 NOTE:

TOTALS AND SUBTOTALS ARE OBTAINED FROM UNROUNDED NUMBERS DATE PRINTED: 2013/05/22 E-148

BROWNS FERRY NUCLEAR PLANT UNITS 1, 2, AND 3 2013 ANNUAL RADIOACTIVE EFFLUENT RELEASE REPORT JOINT PERCENTAGE FREQUENCIES OF WIND SPEED BY WIND DIRECTION FOR STABILITY CLASS F

( 1.5< DELTA T<= 4.0 C/100 M)

BROWNS FERRY NUCLEAR PLANT JAN 1, 2013 -

MAR 31, 2013 WIND DIRECTION WIND SPEED(MPH) 0.6-1.4 1.5-3.4 3.5-5.4 5.5-7.4 N

NNE NE ENE E

ESE SE SSE S

SSW SW WSW W

WNW NW NNW CALM 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 7.5-12.4 12.5-18.4 18.5-24.4 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.047 0.047 0.047 0.000 0.047 0.000 0.000 0.000 0.000 0.187 0.000 0.093 0.000 0.000 0.047 0.140 0.000 0.000 0.000 0.000 0.093 0.047 0.000 0.093 0.000 0.000 0.514 0.000 0.000 0.047 0.093 0.140 0.187 0.000 0.047 0.000 0.000 0.000 0.093 0.000 0.000 0.000 0.093 0.701

>=24.5 TOTAL 0.047 0.187 0.140 0.187 0.140 0.187 0.374 0.187 0.327 0.093 0.093 0.234 0.093 0.093 0.093 0.093 2.569 0.280 0.187 0.140 0.047 0.000 0.093 0.514 1.214 0.981 0.327 0.093 0.093 0.000 0.000 0.093 0.187 4.250 0.000 0.000 0.000 0.000 0.000 0.000 0.234 0.887 0.280 0.000 0.000 0.000 0.000 0.000 0.000 0.000 1.401 0.000 0.000 0.000 0.000 0.000 0.000 0.140 0.607 0.420 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.327 0.467 0.327 0.327 0.327 0.607 1.261 2.989 2.055 0.467 0.280 0.514 0.093 0.187 0.187 0.374 SUBTOTAL 1.168 10.789 TOTAL HOURS OF VALID STABILITY OBSERVATIONS TOTAL HOURS OF STABILITY CLASS F TOTAL TOTAL TOTAL HOURS HOURS HOURS OF VALID WIND DIRECTION-WIND SPEED-STABILITY CLASS F OF VALID WIND DIRECTION-WIND SPEED-STABILITY OBSERVATIONS CALM 2141 231 231 2141 0

METEOROLOGICAL FACILITY:

BROWNS FERRY NUCLEAR PLANT STABILITY BASED ON DELTA-T BETWEEN 10.03 AND 89.59 METERS WIND SPEED AND DIRECTION MEASURED AT 90.29 METER LEVEL DATE PRINTED: 2013/05/22 MEAN WIND SPEED = 15.12 NOTE:

TOTALS AND SUBTOTALS ARE OBTAINED FROM UNROUNDED NUMBERS E-149

BROWNS FERRY NUCLEAR PLANT UNITS 1, 2, AND 3 2013 ANNUAL RADIOACTIVE EFFLUENT RELEASE REPORT JOINT PERCENTAGE FREQUENCIES OF WIND SPEED BY WIND DIRECTION FOR STABILITY CLASS G (DELTA T > 4.0 C/100 M)

BROWNS FERRY NUCLEAR PLANT JAN 1, 2013 -

MAR 31, 2013 WIND DIRECTION N

NNE NE ENE E

ESE SE SSE S

SSW SW WSW W

WNW NW NNW SUBTOTAL WIND SPEED(MPH) 0.6-1.4 1.5-3.4 3.5-5.4 5.5-7.4 CALM 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 7.5-12.4 12.5-18.4 18.5-24.4

>=24.5 TOTAL 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.047 0.000 0.000 0.000 0.093 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.047 0.000 0.187 0.047 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.047 0.093 0.000 0.047 0.093 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.047 0.000 0.000 0.000 0.000 0.187 0.093 0.047 0.047 0.047 0.000 0.000 0.047 0.187 0.000 0.000 0.047 0.000 0.047 0.093 0.000 0.047 0.701 0.000 0.047 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.047 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.093 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.093 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.047 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.047 0.140 0.187 0.140 0.047 0.000 0.093 0.047 0.327 0.000 0.000 0.047 0.047 0.047 0.093 0.047 0.093 1.355 TOTAL HOURS OF VALID STABILITY OBSERVATIONS TOTAL HOURS OF STABILITY CLASS G TOTAL TOTAL TOTAL HOURS HOURS HOURS OF VALID WIND DIRECTION-WIND SPEED-STABILITY CLASS G OF VALID WIND DIRECTION-WIND SPEED-STABILITY OBSERVATIONS CALM 2141 29 29 2141 0

METEOROLOGICAL FACILITY:

BROWNS FERRY NUCLEAR PLANT STABILITY BASED ON DELTA-T BETWEEN 10.03 AND 89.59 METERS WIND SPEED AND DIRECTION MEASURED AT 90.29 METER LEVEL DATE PRINTED: 2013/05/22 MEAN WIND SPEED =

9.23 NOTE:

TOTALS AND SUBTOTALS ARE OBTAINED FROM UNROUNDED NUMBERS E-150

BROWNS FERRY NUCLEAR PLANT UNITS 1, 2, AND 3 2013 ANNUAL RADIOACTIVE EFFLUENT RELEASE REPORT BROWNS FERRY NUCLEAR PLANT 2013 METEOROLOGICAL DATA TABLE 9B JOINT FREQUENCY DISTRIBUTION IN PERCENT FOR ELEVATED RELEASES SECOND QUARTER E-151

BROWNS FERRY NUCLEAR PLANT UNITS 1, 2, AND 3 2013 ANNUAL RADIOACTIVE EFFLUENT RELEASE REPORT JOINT PERCENTAGE FREQUENCIES OF WIND SPEED BY WIND DIRECTION FOR STABILITY CLASS A (DELTA T<=-1.9 C/100 M)

Browns Ferry Nuclear Plant STA 52 D -

Validated Edited Data APR 1, 2013 -

JUN 30, 2013 WIND DIRECTION N

NNE NE ENE E

ESE SE SSE S

SSW SW WSW W

WNW NW NNW SUBTOTAL WIND SPEED(MPH) 0.6-1.4 1.5-3.4 3.5-5.4 5.5-7.4 CALM 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 7.5-12.4 12.5-18.4 18.5-24.4

>=24.5 TOTAL 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.050 0.000 0.000 0.000 0.000 0.050 0.000 0.000 0.000 0.000 0.000 0.000 0.050 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.050 0.000 0.000 0.000 0.000 0.000 0.101 0.151 0.151 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.404 0.000 0.000 0.000 0.000 0.000 0.050 0.000 0.151 0.050 0.000 0.000 0.000 0.000 0.000 0.050 0.000 0.303 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.101 0.050 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.151 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.151 0.202 0.404 0.101 0.000 0.000 0.050 0.000 0.000 0.050 0.000 0.959 TOTAL HOURS OF VALID STABILITY OBSERVATIONS TOTAL HOURS OF STABILITY CLASS A 1982 19 19 1982 TOTAL TOTAL TOTAL HOURS HOURS HOURS OF VALID WIND DIRECTION-WIND SPEED-STABILITY CLASS A OF VALID WIND DIRECTION-WIND SPEED-STABILITY OBSERVATIONS CALM METEOROLOGICAL FACILITY:

Browns Ferry Nuclear Plant STA 52 D -

Validated STABILITY BASED ON DELTA-T BETWEEN 10.03 AND 89.59 METERS WIND SPEED AND DIRECTION MEASURED AT 90.29 METER LEVEL MEAN WIND SPEED = 12.52 NOTE:

TOTALS AND SUBTOTALS ARE OBTAINED FROM UNROUNDED NUMBERS Edited Data DATE PRINTED: 2013/08/12 E-152

BROWNS FERRY NUCLEAR PLANT UNITS 1, 2, AND 3 2013 ANNUAL RADIOACTIVE EFFLUENT RELEASE REPORT JOINT PERCENTAGE FREQUENCIES OF WIND SPEED BY WIND DIRECTION FOR STABILITY CLASS B

(-1.9< DELTA T<=-1.7 C/100 M)

Browns Ferry Nuclear Plant STA 52 D -

Validated Edited Data APR 1, 2013 -

JUN 30, 2013 WIND DIRECTION N

NNE NE ENE E

ESE SE SSE S

SSW SW WSW W

WNW NW NNW SUBTOTAL WIND SPEED(MPH) 0.6-1.4 1.5-3.4 3.5-5.4 5.5-7.4 CALM 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 7.5-12.4 12.5-18.4 18.5-24.4

>=24.5 TOTAL 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.101 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.101 0.050 0.000 0.000 0.000 0.000 0.000 0.202 0.101 0.101 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.454 0.151 0.050 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.202 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.050 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.050 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.202 0.050 0.000 0.000 0.000 0.000 0.303 0.151 0.101 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.807 TOTAL HOURS OF VALID STABILITY OBSERVATIONS TOTAL HOURS OF STABILITY CLASS B TOTAL TOTAL TOTAL HOURS HOURS HOURS OF VALID WIND DIRECTION-WIND SPEED-STABILITY CLASS B OF VALID WIND DIRECTION-WIND SPEED-STABILITY OBSERVATIONS CALM 1982 16 16 1982 0

METEOROLOGICAL FACILITY:

Browns Ferry Nuclear Plant STA 52 D -

Validated STABILITY BASED ON DELTA-T BETWEEN 10.03 AND 89.59 METERS WIND SPEED AND DIRECTION MEASURED AT 90.29 METER LEVEL MEAN WIND SPEED = 11.61 NOTE:

TOTALS AND SUBTOTALS ARE OBTAINED FROM UNROUNDED NUMBERS Edited Data DATE PRINTED: 2013/08/12 E-153

BROWNS FERRY NUCLEAR PLANT UNITS 1, 2, AND 3 2013 ANNUAL RADIOACTIVE EFFLUENT RELEASE REPORT JOINT PERCENTAGE FREQUENCIES OF WIND SPEED BY WIND DIRECTION FOR STABILITY CLASS C

(-1.7< DELTA T<=-l.5 C/100 M)

Browns Ferry Nuclear Plant STA 52 D -

Validated Edited Data APR 1, 2013 -

JUN 30, 2013 WIND DIRECTION N

NNE NE ENE E

ESE SE SSE S

SSW SW WSW W

WNW NW NNW SUBTOTAL WIND SPEED(MPH) 0.6-1.4 1.5-3.4 3.5-5.4 5.5-7.4 CALM 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 7.5-12.4 12.5-18.4 18.5-24.4

>=24.5 TOTAL 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.050 0.000 0.000 0.000 0.000 0.202 0.202 0.050 0.050 0.000 0.000 0.101 0.000 0.000 0.000 0.656 0.000 0.000 0.000 0.000 0.000 0.151 0.252 0.050 0.101 0.000 0.000 0.050 0.000 0.000 0.000 0.050 0.656 0.101 0.252 0.000 0.000 0.000 0.101 0.303 0.000 0.101 0.000 0.151 0.202 0.000 0.050 0.050 0.050 1.362 0.151 0.202 0.000 0.000 0.000 0.000 0.101 0.000 0.101 0.050 0.050 0.000 0.000 0.252 0.050 0.000 0.959 0.000 0.000 0.000 0.000 0.000 0.000 0.050 0.000 0.050 0.000 0.000 0.000 0.000 0.050 0.000 0.000 0.151 0.000 0.000 0.000 0.000 0.000 0.000 0.101 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.101 0.252 0.505 0.000 0.000 0.000 0.252 1.009 0.252 0.404 0.101 0.202 0.252 0.101 0.353 0.101 0.101 3.885 TOTAL HOURS OF VALID STABILITY OBSERVATIONS TOTAL HOURS OF STABILITY CLASS C TOTAL HOURS OF VALID WIND DIRECTION-WIND SPEED-STABILITY CLASS C TOTAL HOURS OF VALID WIND DIRECTION-WIND SPEED-STABILITY OBSERVATIONS TOTAL HOURS CALM METEOROLOGICAL FACILITY:

Browns Ferry Nuclear Plant STA 52 D -

Validated STABILITY BASED ON DELTA-T BETWEEN 10.03 AND 89.59 METERS WIND SPEED AND DIRECTION MEASURED AT 90.29 METER LEVEL MEAN WIND SPEED = 10.43 NOTE:

TOTALS AND SUBTOTALS ARE OBTAINED FROM UNROUNDED NUMBERS 1982 77 77 1982 0

Edited Data DATE PRINTED: 2013/08/12 E-154

BROWNS FERRY NUCLEAR PLANT UNITS 1, 2, AND 3 2013 ANNUAL RADIOACTIVE EFFLUENT RELEASE REPORT JOINT PERCENTAGE FREQUENCIES OF WIND SPEED BY WIND DIRECTION FOR STABILITY CLASS D

(-1.5< DELTA T<=-0.5 C/100 M)

Browns Ferry Nuclear Plant STA 52 D -

Validated Edited Data APR 1, 2013 -

JUN 30, 2013 WIND SPEED(MPH) 0.6-1.4 1.5-3.4 3.5-5.4 5.5-7.4 7.5-12.4 12.5-18.4 18.5-24.4 WIND DIRECTION N

NNE NE ENE E

ESE SE SSE S

SSW SW WSW W

WNW NW NNW SUBTOTAL CALM 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000

>=24.5 TOTAL 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.050 0.000 0.101 0.050 0.050 0.151 0.555 0.353 0.202 0.303 0.555 0.353 0.202 0.101 0.000 0.101 3.128 0.050 0.252 0.202 0.050 0.050 0.252 0.404 0.151 0.202 0.505 0.353 0.605 0.353 0.404 0.151 0.050 4.036 0.353 0.101 0.050 0.151 0.050 0.202 0.404 0.252 0.404 0.252 0.454 0.353 0.555 0.908 0.303 0.353 0.656 0.959 0.404 0.252 0.050 0.303 1.514 1.867 1.615 1.060 1.312 1.110 1.816 1.816 1.362 0.757

0. 605 0.858 0.555 0.151 0.252 0.202 1.211 0.908 1.514 1.060 0.757 0.505 1.009 1.867 0.555 0.303 0.000 0.000 0.000 0.050 0.000 0.151 0.706 0.505 0.404 0.454 0.050 0.101 0.454 0.151 0.151 0.101 3.280 0.000 0.000 0.000 0.000 0.000 0.050 0.454 0.252 0.404 0.000 0.000 0.000 0.000 0.000 0.000 0.000 1.715 2.170 1.312 0.706 0.454 1.312 5.247 4.289 4.743 3.633 3.481 3.027 4.390 5.247 2.523 1.665 5.146 16.852 12.311 1.160 45.913 TOTAL HOURS OF VALID STABILITY OBSERVATIONS TOTAL HOURS OF STABILITY CLASS D TOTAL TOTAL TOTAL HOURS HOURS HOURS OF VALID WIND DIRECTION-WIND SPEED-STABILITY CLASS D OF VALID WIND DIRECTION-WIND SPEED-STABILITY OBSERVATIONS CALM 1982 910 910 1982 0

METEOROLOGICAL FACILITY:

Browns Ferry Nuclear Plant STA 52 D -

Validated STABILITY BASED ON DELTA-T BETWEEN 10.03 AND 89.59 METERS WIND SPEED AND DIRECTION MEASURED AT 90.29 METER LEVEL MEAN WIND SPEED = 11.12 NOTE:

TOTALS AND SUBTOTALS ARE OBTAINED FROM UNROUNDED NUMBERS Edited Data DATE PRINTED: 2013/08/12 E-155

BROWNS FERRY NUCLEAR PLANT UNITS 1, 2, AND 3 2013 ANNUAL RADIOACTIVE EFFLUENT RELEASE REPORT JOINT PERCENTAGE FREQUENCIES OF WIND SPEED BY WIND DIRECTION FOR STABILITY CLASS E

(-0.5< DELTA T<= 1.5 C/100 M)

Browns Ferry Nuclear Plant STA 52 D -

Validated Edited Data APR 1, 2013 -

JUN 30, 2013 WIND DIRECTION WIND SPEED(MPH) 0.6-1.4 1.5-3.4 3.5-5.4 5.5-7.4 N

NNE NE ENE E

ESE SE SSE S

SSW SW WSW W

WNW NW NNW CALM 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 7.5-12.4 12.5-18.4 18.5-24.4

>=24.5 TOTAL 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.050 0.000 0.000 0.000 0.000 0.050 0.000 0.000 0.050 0.000 0.000 0.050 0.000 0.050 0.000 0.000 0.000 0.000 0.101 0.101 0.000 0.101 0.454 0.000 0.101 0.252 0.101 0.000 0.050 0.101 0.101 0.151 0.050 0.151 0.252 0.404 0.202 0.050 0.000 1.968 0.202 0.000 0.101 0.050 0.050 0.252 0.404 0.303 0.201 0.252 0.151 0.252 0.252 0.605 0.151 0.101 0.605 0.404 0.353 0.151 0.252 0.303 1.060 1.968 1.413

0. 656 0.858 0.807 1.211 0.505 0.353 0.202 1.009 0.454 0.404 0.101 0.555 0.505 0.959 1.413 2.523 0.505 0.505 0.101 0.101 0.101 0.151 0.757 0.050 0.000 0.050 0.000 0.000 0.303 0.858 1.362 1.261 0.050 0.000 0.000 0.050 0.303 0.101 0.000 4.390 0.000 0.000 0.000 0.000 0.000 0.000 0.101 0.303 0.303 0.101 0.000 0.000 0.000 0.000 0.000 0.000 1.867
0. 959 1.211 0.404 0.858 1.463 3.481 5.499 5.752 1.615 1.665 1.463 2.119 1.816 0.807 1.160 SUBTOTAL 3.229 11.100 10.141 0.807 32.139 TOTAL HOURS OF VALID STABILITY OBSERVATIONS TOTAL HOURS OF STABILITY CLASS E TOTAL HOURS OF VALID WIND DIRECTION-WIND SPEED-STABILITY CLASS E TOTAL HOURS OF VALID WIND DIRECTION-WIND SPEED-STABILITY OBSERVATIONS TOTAL HOURS CALM METEOROLOGICAL FACILITY:

Browns Ferry Nuclear Plant STA 52 D -

Validated STABILITY BASED ON DELTA-T BETWEEN 10.03 AND 89.59 METERS WIND SPEED AND DIRECTION MEASURED AT 90.29 METER LEVEL MEAN WIND SPEED = 12.70 NOTE:

TOTALS AND SUBTOTALS ARE OBTAINED FROM UNROUNDED NUMBERS 1982 637 637 1982 0

Edited Data DATE PRINTED: 2013/08/12 E-156

BROWNS FERRY NUCLEAR PLANT UNITS 1, 2, AND 3 2013 ANNUAL RADIOACTIVE EFFLUENT RELEASE REPORT JOINT PERCENTAGE FREQUENCIES OF WIND SPEED BY WIND DIRECTION FOR STABILITY CLASS F

( 1.5< DELTA T<= 4.0 C/100 M)

Browns Ferry Nuclear Plant STA 52 D -

Validated Edited Data APR 1, 2013 -

JUN 30, 2013 WIND SPEED(MPH) 0.6-1.4 1.5-3.4 3.5-5.4 5.5-7.4 7.5-12.4 12.5-18.4 18.5-24.4 WIND DIRECTION N

NNE NE ENE E

ESE SE SSE S

SSW SW WSW W

WNW NW NNW SUBTOTAL CALM 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000

>=24.5 TOTAL 0.000 0.000 0.000 0.000 0.000 0.000 0.050 0.000 0.000 0.000 0.000 0.000 0.050 0.000 0.000 0.000 0.101 0.050 0.000 0.050 0.000 0.000 0.000 0.050 0.050 0.000 0.000 0.000 0.000 0.101 0.050 0.101 0.000 0.454 0.050 0.000 0.000 0.101 0.000 0.050 0.101 0.000 0.050 0.101 0.050 0.000 0.101 0.050 0.050 0.101 0.807 0.050 0.050 0.000 0.000 0.050 0.151 0.050 0.000 0.050 0.101 0.050 0.050 0.050 0.101 0.050 0.050 0.858 0.252 0.151 0.050 0.151 0.101 0.353 0.706 0.353 0.303 0.303 0.252 0.252 0.303 0.252 0.101 0.050 3.935 0.101 0.151 0.505 0.303 0.101 0.555 0.101 1.009 1.564 0.757 0.353 0.101 0.000 0.000 0.000 0.202 5.802 0.000 0.101 0.202 0.151 0.000 0.050 0.000 0.454 0.202 0.101 0.000 0.000 0.000 0.000 0.000 0.050 1.312 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.505 0.454 0.807 0.706 0.252 1.160 1.060 1.867 2.170

1. 362 0.706 0.404 0.605
0. 454 0.303 0.454 0.000 13.269 TOTAL HOURS OF VALID STABILITY OBSERVATIONS TOTAL HOURS OF STABILITY CLASS F TOTAL TOTAL TOTAL HOURS HOURS HOURS OF VALID WIND DIRECTION-WIND SPEED-STABILITY CLASS F OF VALID WIND DIRECTION-WIND SPEED-STABILITY OBSERVATIONS CALM 1982 263 263 1982 0

METEOROLOGICAL FACILITY:

Browns Ferry Nuclear Plant STA 52 D -

Validated Edited Data STABILITY BASED ON DELTA-T BETWEEN 10.03 AND 89.59 METERS WIND SPEED AND DIRECTION MEASURED AT 90.29 METER LEVEL DATE PRINTED: 2013/08/12 MEAN WIND SPEED = 12.43 NOTE:

TOTALS AND SUBTOTALS ARE OBTAINED FROM UNROUNDED NUMBERS E-157

BROWNS FERRY NUCLEAR PLANT UNITS 1, 2, AND 3 2013 ANNUAL RADIOACTIVE EFFLUENT RELEASE REPORT JOINT PERCENTAGE FREQUENCIES OF WIND SPEED BY WIND DIRECTION FOR STABILITY CLASS G (DELTA T > 4.0 C/100 M)

Browns Ferry Nuclear Plant STA 52 D -

Validated Edited Data APR 1, 2013 -

JUN 30, 2013 WIND DIRECTION N

NNE NE ENE E

ESE SE SSE S

SSW SW WSW W

WNW NW NNW SUBTOTAL WIND SPEED(MPH) 0.6-1.4 1.5-3.4 3.5-5.4 5.5-7.4 CALM 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 7.5-12.4 12.5-18.4 18.5-24.4

>=24.5 TOTAL 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.050 0.050 0.151 0.151 0.050 0.000 0.000 0.000 0.000 0.050 0.000 0.000 0.000 0.505 0.050 0.000 0.050 0.000 0.000 0.050 0.000 0.000 0.000 0.000 0.000 0.000 0.050 0.000 0.050 0.050 0.303 0.000 0.000 0.000 0.101 0.101 0.252 0.000 0.000 0.000 0.000 0.000 0.050 0.000 0.000 0.000 0.000 0.505 0.000 0.151 0.000 0.000 0.101 0.000 0.000 0.000 0.050 0.000 0.000 0.151 0.000 0.000 0.000 0.050 0.505 0.000 0.050 0.000 0.101 0.101 0.101 0.000 0.252 0.202 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.807 0.000 0.000 0.000 0.050 0.000 0.000 0.000 0.202 0.151 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.404 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.050 0.202 0.050 0.303 0.353 0.555 0.151 0.505 0.404 0.000 0.000 0.202 0.101 0.000 0.050 0.101 3.027 TOTAL HOURS OF VALID STABILITY OBSERVATIONS TOTAL HOURS OF STABILITY CLASS G TOTAL TOTAL TOTAL HOURS HOURS HOURS OF VALID WIND DIRECTION-WIND SPEED-STABILITY CLASS G OF VALID WIND DIRECTION-WIND SPEED-STABILITY OBSERVATIONS CALM 1982 60 60 1982 0

METEOROLOGICAL FACILITY:

Browns Ferry Nuclear Plant STA 52 D -

Validated STABILITY BASED ON DELTA-T BETWEEN 10.03 AND 89.59 METERS WIND SPEED AND DIRECTION MEASURED AT 90.29 METER LEVEL MEAN WIND SPEED = 10.51 NOTE:

TOTALS AND SUBTOTALS ARE OBTAINED FROM UNROUNDED NUMBERS Edited Data DATE PRINTED: 2013/08/12 E-158

BROWNS FERRY NUCLEAR PLANT UNITS 1, 2, AND 3 2013 ANNUAL RADIOACTIVE EFFLUENT RELEASE REPORT JOINT PERCENTAGE FREQUENCIES OF WIND SPEED BY WIND DIRECTION DISREGARDING STABILITY CLASS Browns Ferry Nuclear Plant STA 52 D -

Validated Edited Data APR 1, 2013 -

JUN 30, 2013 WIND SPEED(MPH) 0.6-1.4 1.5-3.4 3.5-5.4 5.5-7.4 7.5-12.4 12.5-18.4 18.5-24.4 WIND DIRECTION N

NNE NE ENE E

ESE SE SSE S

SSW SW WSW W

WNW NW NNW SUBTOTAL CALM 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000

>=24.5 TOTAL 0.000 0.000 0.000 0.000 0.000 0.000 0.046 0.000 0.000 0.000 0.000 0.046 0.046 0.000 0.000 0.000 0.138 0.092 0.000 0.184 0.092 0.092 0.322 0.735 0.505 0.230 0.276 0.505 0.367 0.413 0.230 0.138 0.230 4.410 0.138 0.367 0.459 0.230 0.046 0.413 0.735 0.459 0.413 0.643 0.505 0.873 0.919 0.643 0.276 0.230 0.551 0.138 0.138 0.276 0.276 1.056 1.378 0.689 0.643 0.597 0.597 0.689 0.827 1.470 0.505 0.551 1.700 1.746 0.919 0.551 0.551 1.516 4.088 4.318 3.491 2.021 2.343 2.297 3.124 2.480 1.700 1.148 1.883 1.608 1.470 0.643 0.919 2.848 2.389 3.445 5.972 2.389 1.516 0.643 1.148 2.067 0.781 1.240 0.046 0.092 0.367 0.413 0.000 1.194 1.837 2.435 2.067 0.643 0.046 0.092 0.551 0.643 0.276 0.138 0.000 0.000 0.000 0.000 0.000 0.046 0.643 0.505 0.643 0.092 0.000 0.000 0.000 0.000 0.000 0.000 4.410 3.950 3.537 2.205 1.883 7.395 11.851 12.356 13.459 6.661 5.512 5.007 7.028 7.533

3. 675 3.537 7.350 10.381 33.992 30.960 10.841 1.929 100.000 TOTAL HOURS OF VALID WIND OBSERVATIONS TOTAL HOURS OF OBSERVATIONS RECOVERABILITY PERCENTAGE TOTAL HOURS CALM 2177 2184 99.7 0

METEOROLOGICAL FACILITY:

Browns Ferry Nuclear Plant STA 52 D WIND SPEED AND DIRECTION MEASURED AT 90.29 METER LEVEL MEAN WIND SPEED = 11.95 Validated Edited Data DATE PRINTED: 2013/08/12 NOTE:

TOTALS AND SUBTOTALS ARE OBTAINED FROM UNROUNDED NUMBERS E-159

WIND SPEED (MPH)

CALM 0.6-1.4 1.5-3.4 3.5-5.4 5.5-7.4 7.5-12.4 12.5-18.4 18.5-24.4

>=24.5 TOTAL A

0.000 0.000 0.000 0.050 0.050 0.404 0.303 0.151 0.000 0.959 BROWNS FERRY NUCLEAR PLANT UNITS 1, 2, AND 3 2013 ANNUAL RADIOACTIVE EFFLUENT RELEASE REPORT JOINT PERCENTAGE FREQUENCIES OF WIND SPEED BY STABILITY CLASS Browns Ferry Nuclear Plant STA 52 D -

Validated Edited Data APR 1, 2013 -

JUN 30, 2013 STABILITY CLASS B

C D

E 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.050 0.000 0.000 3.128 0.454 0.000 0.656 4.036 1.968 0.101 0.656 5.146 3.229 0.454 1.362 16.852 11.100 0.202 0.959 12.311 10.141 0.050 0.151 3.280 4.390 F

0.000 0.101 0.454 0.807 0.858 3.935 5.802 1.312 0.000 13.269 G

0.000 0.000 0.505 0.303 0.505 0.505 0.807 0.404 0.000 3.027 0.000 0.807 0.101 3.885 1.160 45.913 0.807 32.139 TOTAL HOURS OF VALID STABILITY OBSERVATIONS TOTAL HOURS OF VALID WIND DIRECTION-WIND SPEED-STABILITY TOTAL HOURS OF OBSERVATIONS JOINT RECOVERABILITY PERCENTAGE 1982 OBSERVATIONS 1982 2184 90.8 METEOROLOGICAL FACILITY:

Browns Ferry Nuclear Plant STA 52 D -

Validated Edited Data STABILITY BASED ON DELTA-T BETWEEN 10.03 AND 89.59 METERS WIND SPEED AND DIRECTION MEASURED AT 90.29 METER LEVEL DATE PRINTED: 2013/08/12 E-1 60

BROWNS FERRY NUCLEAR PLANT UNITS 1, 2, AND 3 2013 ANNUAL RADIOACTIVE EFFLUENT RELEASE REPORT BROWNS FERRY NUCLEAR PLANT 2013 METEOROLOGICAL DATA TABLE 9C JOINT FREQUENCY DISTRIBUTION IN PERCENT FOR ELEVATED RELEASES THIRD QUARTER E-161

BROWNS FERRY NUCLEAR PLANT UNITS 1, 2, AND 3 2013 ANNUAL RADIOACTIVE EFFLUENT RELEASE REPORT JOINT PERCENTAGE FREQUENCIES OF WIND SPEED BY WIND DIRECTION FOR STABILITY CLASS A (DELTA T<=-1.9 C/100 M)

BROWNS FERRY NUCLEAR PLANT JUL 1, 2013 -

SEP 30, 2013 WIND DIRECTION N

NNE NE ENE E

ESE SE SSE S-SSW SW WSW W

WNW NW NNW SUBTOTAL WIND SPEED(MPH) 0.6-1.4 1.5-3.4 3.5-5.4 5.5-7.4 CALM 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 7.5-12.4 12.5-18.4 18.5-24.4

>=24.5 TOTAL 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.137 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.137 0.000 0.000 0.000 0.000 0.000 0.000 0.046 0.046 0.091 0.000 0.046 0.000 0.000 0.000 0.000 0.000 0.229 0.046 0.000 0.000 0.000 0.000 0.000 0.046 0.000 0.000 0.000 0.000 0.000 0.046 0.000 0.000 0.000 0.137 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.046 0.000 0.000 0.000 0.000 0.000 0.091 0.183 0.091 0.000 0.046 0.000 0.046 0.000 0.000 0.000 0.503 TOTAL HOURS OF VALID STABILITY OBSERVATIONS TOTAL HOURS OF STABILITY CLASS A TOTAL TOTAL TOTAL HOURS HOURS HOURS OF VALID WIND DIRECTION-WIND SPEED-STABILITY CLASS A OF VALID WIND DIRECTION-WIND SPEED-STABILITY OBSERVATIONS CALM 2188 11 11 2187 0

METEOROLOGICAL FACILITY:

BROWNS FERRY NUCLEAR PLANT STABILITY BASED ON DELTA-T BETWEEN 10.03 AND 89.59 METERS WIND SPEED AND DIRECTION MEASURED AT 90.29 METER LEVEL MEAN WIND SPEED = 10.25 NOTE:

TOTALS AND SUBTOTALS ARE OBTAINED FROM UNROUNDED NUMBERS DATE PRINTED: 2013/11/15 E-162

BROWNS FERRY NUCLEAR PLANT UNITS 1, 2, AND 3 2013 ANNUAL RADIOACTIVE EFFLUENT RELEASE REPORT JOINT PERCENTAGE FREQUENCIES OF WIND SPEED BY WIND DIRECTION FOR STABILITY CLASS B

(-1.9< DELTA T<=-1.7 C/100 M)

BROWNS FERRY NUCLEAR PLANT JUL 1, 2013 -

SEP 30, 2013 WIND DIRECTION N

NNE NE ENE E

ESE SE SSE S

SSW SW WSW W

WNW NW NNW SUBTOTAL WIND SPEED(MPH) 0.6-1.4 1.5-3.4 3.5-5.4 5.5-7.4 CALM 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 7.5-12.4 12.5-18.4 18.5-24.4

>=24.5 TOTAL 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.046 0.091 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.137 0.000 0.000 0.000 0.000 0.000 0.000 0.091 0.366 0.046 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.503 0.000 0.000 0.000 0.000 0.000 0.091 0.412 0.091 0.183 0.046 0.000 0.000 0.000 0.000 0.000 0.000 0.823 0.000 0.000 0.000 0.000 0.000 0.000 0.046 0.000 0.046 0.046 0.000 0.000 0.046 0.046 0.000 0.000 0.229 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.046 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.046 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.091 0.594 0.594 0.274 0.091 0.000 0.000 0.046 0.046 0.000 0.000 1.738 TOTAL HOURS OF VALID STABILITY OBSERVATIONS TOTAL HOURS OF STABILITY CLASS B TOTAL TOTAL TOTAL HOURS HOURS HOURS OF VALID WIND DIRECTION-WIND SPEED-STABILITY CLASS B OF VALID WIND DIRECTION-WIND SPEED-STABILITY OBSERVATIONS CALM 2188 38 38 2187 0

METEOROLOGICAL FACILITY:

BROWNS FERRY NUCLEAR PLANT STABILITY BASED ON DELTA-T BETWEEN 10.03 AND 89.59 METERS WIND SPEED AND DIRECTION MEASURED AT 90.29 METER LEVEL DATE PRINTED: 2013/11/15 MEAN WIND SPEED =

9.23 NOTE:

TOTALS AND SUBTOTALS ARE OBTAINED FROM UNROUNDED NUMBERS E-163

BROWNS FERRY NUCLEAR PLANT UNITS 1, 2, AND 3 2013 ANNUAL RADIOACTIVE EFFLUENT RELEASE REPORT JOINT PERCENTAGE FREQUENCIES OF WIND SPEED BY WIND DIRECTION FOR STABILITY CLASS C

(-1.7< DELTA T<=-1.5 C/100 M)

BROWNS FERRY NUCLEAR PLANT JUL 1, 2013 -

SEP 30, 2013 WIND DIRECTION N

NNE NE ENE E

ESE SE SSE S

SSW SW WSW W

WNW NW NNW SUBTOTAL WIND SPEED(MPH) 0.6-1.4 1.5-3.4 3.5-5.4 5.5-7.4 CALM 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 7.5-12.4 12.5-18.4 18.5-24.4

>=24.5 TOTAL 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.046 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.046 0.000 0.000 0.000 0.000 0.000 0.000 0.229 0.183 0.000 0.046 0.046 0.137 0.000 0.000 0.000 0.000 0.640 0.091 0.091 0.000 0.000 0.000 0.091 0.320 0.000 0.183 0.137 0.000 0.137 0.274 0.000 0.046 0.000 1.372 0.183 0.183 0.046 0.000 0.000 0.503 0.366 0.000 0.091 0.000 0.091 0.000 0.274 0.137 0.137 0.137 2.149 0.046

0. 137 0.046 0.000 0.000 0.183 0.046 0.000 0.000 0.000 0.000 0.000 0.000 0.137 0.000 0.046 0.640 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.320 0.412 0.091 0.000 0.000 0.777 1.006 0.183 0.274 0.183 0.137 0.274 0.549 0.274 0.183 0.183 4.847 TOTAL HOURS OF VALID STABILITY OBSERVATIONS TOTAL HOURS OF STABILITY CLASS C TOTAL TOTAL TOTAL HOURS HOURS HOURS OF VALID WIND DIRECTION-WIND SPEED-STABILITY CLASS C OF VALID WIND DIRECTION-WIND SPEED-STABILITY OBSERVATIONS CALM 2188 107 106 2187 0

METEOROLOGICAL FACILITY:

BROWNS FERRY NUCLEAR PLANT STABILITY BASED ON DELTA-T BETWEEN 10.03 AND 89.59 METERS WIND SPEED AND DIRECTION MEASURED AT 90.29 METER LEVEL DATE PRINTED: 2013/11/15 MEAN WIND SPEED =

8.86 NOTE:

TOTALS AND SUBTOTALS ARE OBTAINED FROM UNROUNDED NUMBERS E-164

BROWNS FERRY NUCLEAR PLANT UNITS 1, 2, AND 3 2013 ANNUAL RADIOACTIVE EFFLUENT RELEASE REPORT JOINT PERCENTAGE FREQUENCIES OF WIND SPEED BY WIND DIRECTION FOR STABILITY CLASS D

(-1.5< DELTA T<=-0.5 C/100 M)

BROWNS FERRY NUCLEAR PLANT JUL 1, 2013 -

SEP 30, 2013 WIND DIRECTION N

NNE NE ENE E

ESE SE SSE S

SSW SW WSW W

WNW NW NNW SUBTOTAL WIND SPEED(MPH) 0.6-1.4 1.5-3.4 3.5-5.4 5.5-7.4 7.5-12.4 12.5-18.4 CALM 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 18.5-24.4

>=24.5 TOTAL 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.046 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.046 0.091 0.137 0.137 0.183 0.183 0.320 0.457 0.640 0.412 0.640 0.732 0.412 0.274 0.091 0.137 0.183 5.030 0.274 0.229 0.183 0.320 0.183 0.366 0.823 1.097 0.777 0.640 0.640 1.052 0.732 0.503 0.229 0.229 8.276 0.549 0.229 0.274 0.183 0.274 0.457 0.777 0.777 0.960 0.594 0.503 0.777 1.097 0.412 0.274 0.183 1.143 1.052 0.274 0.000 0.686 1.783 1.646 2.332 1.097 0.823 0.457 0.732 1.189 1.189 0.503 0.960 0.549 0.686 0.046 0.000 0.320 1.555 2.012 1.509 0.412 0.091 0.091 0.000 0.183 0.137 0.046 0.183 7.819 0.046 0.000 0.000 0.000 0.000 0.091 0.914 0.091 0.046 0.000 0.000 0.000 0.000 0.000 0.000 0.046 1.235 0.000 0.000 0.000 0.000 0.000 0.000 0.046 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 2.652 2.332 0.914 0.686 1.646 4.572 6.676 6.493 3.704 2.789 2.423 2.972 3.475 2.332 1.189 1.783 8.322 15.866 0.046 46.639 TOTAL HOURS OF VALID STABILITY OBSERVATIONS TOTAL HOURS OF STABILITY CLASS D TOTAL TOTAL TOTAL HOURS HOURS HOURS OF VALID WIND DIRECTION-WIND SPEED-STABILITY CLASS D OF VALID WIND DIRECTION-WIND SPEED-STABILITY OBSERVATIONS CALM 2188 1020 1020 2187 0

METEOROLOGICAL FACILITY:

BROWNS FERRY NUCLEAR PLANT STABILITY BASED ON DELTA-T BETWEEN 10.03 AND 89.59 METERS WIND SPEED AND DIRECTION MEASURED AT 90.29 METER LEVEL DATE PRINTED: 2013/11/15 MEAN WIND SPEED =

8.61 NOTE:

TOTALS AND SUBTOTALS ARE OBTAINED FROM UNROUNDED NUMBERS E-165

BROWNS FERRY NUCLEAR PLANT UNITS 1, 2, AND 3 2013 ANNUAL RADIOACTIVE EFFLUENT RELEASE REPORT JOINT PERCENTAGE FREQUENCIES OF WIND SPEED BY WIND DIRECTION FOR STABILITY CLASS E

(-0.5< DELTA T<= 1.5 C/100 M)

BROWNS FERRY NUCLEAR PLANT JUL 1, 2013 -

SEP 30, 2013 WIND DIRECTION WIND SPEED(MPH) 0.6-1.4 1.5-3.4 3.5-5.4 5.5-7.4 N

NNE NE ENE E

ESE SE SSE S

SSW SW WSW W

WNW NW NNW CALM 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 7.5-12.4 12.5-18.4 18.5-24.4 0.000 0.000 0.000 0.000 0.000 0.000 0.046 0.046 0.000 0.000 0.091 0.000 0.000 0.000 0.000 0.000 0.183 0.046 0.046 0.091 0.046 0.046 0.137 0.046 0.274 0.137 0.137 0.183 0.137 0.000 0.046 0.046 0.046 1.463 0.137 0.046 0.137 0.183 0.091 0.274 0.366 0.686 0.274 0.320 0.503 0.183 0.274 0.274 0.091 0.274 4.115 0.274 0.137 0.137 0.000 0.137 0.320 0.686 1.006 0.777 0.412 0.366 0.274 0.320 0.229 0.412 0.183 0.549 0.732 0.960 0.183 0.366 1.920 2.103 1.509 1.052 0.777 0.320 0.137 0.366 0.412 0.412 0.412 0.686 1.326 0.549 0.229 0.137 2.149 1.417 0.503 0.137 0.091 0.000 0.046 0.046 0.000 0.046 0.046 7.407 0.000 0.091 0.137 0.000 0.000 0.000 0.046 0.091 0.000 0.000 0.000 0.000 0.000 0.046 0.000 0.000 0.412

>=24.5 TOTAL 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.046 0.000 0.000 1.692 2.378 2.012 0.640 0.777 4.801 4.710 4.115 2.378 1.738 1.463 0.777 1.006 1.052 1.006 0.960 SUBTOTAL 5.670 12.209 0.046 31.504 TOTAL HOURS OF VALID STABILITY OBSERVATIONS TOTAL HOURS OF STABILITY CLASS E TOTAL TOTAL TOTAL HOURS HOURS HOURS OF VALID WIND DIRECTION-WIND SPEED-STABILITY CLASS E OF VALID WIND DIRECTION-WIND SPEED-STABILITY OBSERVATIONS CALM 2188 689 689 2187 0

METEOROLOGICAL FACILITY:

BROWNS FERRY NUCLEAR PLANT STABILITY BASED ON DELTA-T BETWEEN 10.03 AND 89.59 METERS WIND SPEED AND DIRECTION MEASURED AT 90.29 METER LEVEL DATE PRINTED: 2013/11/15 MEAN WIND SPEED =

9.54 NOTE:

TOTALS AND SUBTOTALS ARE OBTAINED FROM UNROUNDED NUMBERS E-166

BROWNS FERRY NUCLEAR PLANT UNITS 1, 2, AND 3 2013 ANNUAL RADIOACTIVE EFFLUENT RELEASE REPORT JOINT PERCENTAGE FREQUENCIES OF WIND SPEED BY WIND DIRECTION FOR STABILITY CLASS F

( 1.5< DELTA T<= 4.0 C/100 M)

BROWNS FERRY NUCLEAR PLANT JUL 1, 2013 -

SEP 30, 2013 WIND DIRECTION N

NNE NE ENE E

ESE SE SSE S

SSW SW WSW W

WNW NW NNW SUBTOTAL WIND SPEED(MPH) 0.6-1.4 1.5-3.4 3.5-5.4 5.5-7.4 7.5-12.4 12.5-18.4 CALM 0.000 0.000 0.003 0.002 0.000 0.003 0.002 0.009 0.003 0.011 0.005 0.002 0.000 0.005 0.002 0.000 0.046 18.5-24.4

>=24.5 TOTAL 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.091 0.000 0.046 0.046 0.000 0.000 0.000 0.000 0.000 0.183 0.000 0.000 0.091 0.046 0.000 0.091 0.046 0.183 0.091 0.274 0.091 0.046 0.000 0.137 0.046 0.000 1.143 0.000 0.091 0.046 0.000 0.091 0.183 0.274 0.274 0.229 0.091 0.320 0.046 0.091 0.091 0.046 0.046 1.920 0.091 0.137 0.046 0.091 0.046 0.183 0.137 0.320 0.091 0.183 0.091 0.000 0.000 0.046 0.274 0.091 1.829 0.046 0.274 0.366 0.594 0.274 0.183 0.686 0.503 0.091 0.000 0.000 0.000 0.091 0.137 0.137 0.046 3.429 0.686 1.280 0.823 0.503 0.091 0.229 0.229 0.046 0.000 0.000 0.000 0.000 0.046 0.000 0.000 0.000 3.932 0.000 0.320 0.137 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.457 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.823 2.103 1.512 1.236 0.503 0.872 1.373 1.427 0.506 0.605 0.553 0.093 0.229 0.416 0.505 0.183 0.000 12.940 TOTAL HOURS OF VALID STABILITY OBSERVATIONS TOTAL HOURS OF STABILITY CLASS F TOTAL TOTAL TOTAL HOURS HOURS HOURS OF VALID WIND DIRECTION-WIND SPEED-STABILITY CLASS F OF VALID WIND DIRECTION-WIND SPEED-STABILITY OBSERVATIONS CALM 2188 283 283 2187 1

METEOROLOGICAL FACILITY:

BROWNS FERRY NUCLEAR PLANT STABILITY BASED ON DELTA-T BETWEEN 10.03 AND 89.59 METERS WIND SPEED AND DIRECTION MEASURED AT 90.29 METER LEVEL DATE PRINTED: 2013/11/15 MEAN WIND SPEED =

9.72 NOTE:

TOTALS AND SUBTOTALS ARE OBTAINED FROM UNROUNDED NUMBERS E-167

BROWNS FERRY NUCLEAR PLANT UNITS 1, 2, AND 3 2013 ANNUAL RADIOACTIVE EFFLUENT RELEASE REPORT JOINT PERCENTAGE FREQUENCIES OF WIND SPEED BY WIND DIRECTION FOR STABILITY CLASS G (DELTA T > 4.0 C/100 M)

BROWNS FERRY NUCLEAR PLANT JUL 1, 2013 -

SEP 30, 2013 WIND DIRECTION N

NNE NE ENE E

ESE SE SSE S

SSW SW WSW W

WNW NW NNW SUBTOTAL WIND SPEED(MPH) 0.6-1.4 1.5-3.4 3.5-5.4 5.5-7.4 7.5-12.4 12.5-18.4 CALM 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 18.5-24.4

>=24.5 TOTAL 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.091 0.000 0.046 0.000 0.000 0.091 0.046 0.046 0.000 0.000 0.046 0.046 0.046 0.000 0.000 0.091 0.549 0.000 0.046 0.000 0.000 0.046 0.137 0.137 0.091 0.046 0.000 0.046 0.046 0.000 0.000 0.000 0.000 0.594 0.000 0.000 0.000 0.000 0.000 0.046 0.000 0.137 0.046 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.229 0.000 0.000 0.000 0.000 0.091 0.046 0.000 0.091 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.229 0.000 0.046 0.091 0.000 0.091 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.229 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.091 0.091 0.137 0.000 0.229 0.320 0.183 0.366 0.091 0.000 0.091 0.091 0.046 0.000 0.000 0.091 1.829 TOTAL HOURS OF VALID STABILITY OBSERVATIONS TOTAL HOURS OF STABILITY CLASS G TOTAL TOTAL TOTAL HOURS HOURS HOURS OF VALID WIND DIRECTION-WIND SPEED-STABILITY CLASS G OF VALID WIND DIRECTION-WIND SPEED-STABILITY OBSERVATIONS CALM 2188 40 40 2187 0

METEOROLOGICAL FACILITY:

BROWNS FERRY NUCLEAR PLANT STABILITY BASED ON DELTA-T BETWEEN 10.03 AND 89.59 METERS WIND SPEED AND DIRECTION MEASURED AT 90.29 METER LEVEL DATE PRINTED: 2013/11/15 MEAN WIND SPEED =

6.28 NOTE:

TOTALS AND SUBTOTALS ARE OBTAINED FROM UNROUNDED NUMBERS E-1 68

BROWNS FERRY NUCLEAR PLANT UNITS 1, 2, AND 3 2013 ANNUAL RADIOACTIVE EFFLUENT RELEASE REPORT BROWNS FERRY NUCLEAR PLANT 2013 METEOROLOGICAL DATA TABLE 9D JOINT FREQUENCY DISTRIBUTION IN PERCENT FOR ELEVATED RELEASES FOURTH QUARTER E-169

BROWNS FERRY NUCLEAR PLANT UNITS 1, 2, AND 3 2013 ANNUAL RADIOACTIVE EFFLUENT RELEASE REPORT JOINT PERCENTAGE FREQUENCIES OF WIND SPEED BY WIND DIRECTION FOR STABILITY CLASS A (DELTA T<=-1.9 C/100 M)

BROWNS FERRY NUCLEAR PLANT OCT 1, 2013 -

DEC 31, 2013 WIND DIRECTION N

NNE NE ENE E

ESE SE SSE S

SSW SW WSW W

WNW NW NNW SUBTOTAL WIND SPEED(MPH) 0.6-1.4 1.5-3.4 3.5-5.4 5.5-7.4 7.5-12.4 12.5-18.4 18.5-24.4

>=24.5 TOTAL CALM 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.091 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.091 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.181 0.091 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.272 0.000 0.000 0.000 0.000 0.000 0.000 0.045 0.136 0.045 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.227 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.045 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.045 0.091 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.091 0.091 0.000 0.000 0.000 0.000 0.000 0.045 0.454 0.136 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.726 TOTAL HOURS OF VALID STABILITY OBSERVATIONS TOTAL HOURS OF STABILITY CLASS A TOTAL TOTAL TOTAL HOURS HOURS HOURS OF VALID WIND DIRECTION-WIND SPEED-STABILITY CLASS A OF VALID WIND DIRECTION-WIND SPEED-STABILITY OBSERVATIONS CALM 2204 16 16 2204 0

METEOROLOGICAL FACILITY:

BROWNS FERRY NUCLEAR PLANT STABILITY BASED ON DELTA-T BETWEEN 10.03 AND 89.59 METERS WIND SPEED AND DIRECTION MEASURED AT 90.29 METER LEVEL DATE PRINTED: 2014/02/25 MEAN WIND SPEED = 13.74 NOTE:

TOTALS AND SUBTOTALS ARE OBTAINED FROM UNROUNDED NUMBERS E-170

BROWNS FERRY NUCLEAR PLANT UNITS 1, 2, AND 3 2013 ANNUAL RADIOACTIVE EFFLUENT RELEASE REPORT JOINT PERCENTAGE FREQUENCIES OF WIND SPEED BY WIND DIRECTION FOR STABILITY CLASS B

(-1.9< DELTA T<=-1.7 C/100 M)

BROWNS FERRY NUCLEAR PLANT OCT 1, 2013 -

DEC 31, 2013 WIND DIRECTION N

NNE NE ENE E

ESE SE SSE S

SSW SW WSW W

WNW NW NNW SUBTOTAL WIND SPEED(MPH) 0.6-1.4 1.5-3.4 3.5-5.4 5.5-7.4 CALM 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 7.5-12.4 12.5-18.4 18.5-24.4

>=24.5 TOTAL 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.045 0.091 0.045 0.000 0.045 0.000 0.000 0.000 0.000 0.000 0.227 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.045 0.181 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.227 0.045 0.000 0.000 0.000 0.000 0.091 0.000 0.091 0.045 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.272 0.000 0.000 0.000 0.000 0.000 0.000 0.045 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.045 0.045 0.000 0.000 0.000 0.000 0.000 0.045 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.091 0.091 0.000 0.000 0.000 0.000 0.091 0.136 0.227 0.272 0.000 0.045 0.000 0.000 0.000 0.000 0.000 0.862 TOTAL HOURS OF VALID STABILITY OBSERVATIONS TOTAL HOURS OF STABILITY CLASS B TOTAL TOTAL TOTAL HOURS HOURS HOURS OF VALID WIND DIRECTION-WIND SPEED-STABILITY CLASS B OF VALID WIND DIRECTION-WIND SPEED-STABILITY OBSERVATIONS CALM 2204 19 19 2204 0

METEOROLOGICAL FACILITY:

BROWNS FERRY NUCLEAR PLANT STABILITY BASED ON DELTA-T BETWEEN 10.03 AND 89.59 METERS WIND SPEED AND DIRECTION MEASURED AT 90.29 METER LEVEL DATE PRINTED: 2014/02/25 MEAN WIND SPEED = 13.13 NOTE:

TOTALS AND SUBTOTALS ARE OBTAINED FROM UNROUNDED NUMBERS E-171

BROWNS FERRY NUCLEAR PLANT UNITS 1, 2, AND 3 2013 ANNUAL RADIOACTIVE EFFLUENT RELEASE REPORT JOINT PERCENTAGE FREQUENCIES OF WIND SPEED BY WIND DIRECTION FOR STABILITY CLASS C

(-1.7< DELTA T<=-1.5 C/100 M)

BROWNS FERRY NUCLEAR PLANT OCT 1, 2013 -

DEC 31, 2013 WIND DIRECTION N

NNE NE ENE E

ESE SE SSE S

SSW SW WSW W

WNW NW NNW SUBTOTAL WIND SPEED(MPH) 0.6-1.4 1.5-3.4 3.5-5.4 5.5-7.4 7.5-12.4 12.5-18.4 18.5-24.4 CALM 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000

>=24.5 TOTAL 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.045 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.045 0.000 0.000 0.000 0.000 0.000 0.000 0.045 0.000 0.227 0.000 0.045 0.000 0.000 0.000 0.000

0. 000 0.318 0.000 0.000 0.000 0.000 0.000 0.000 0.181 0.045 0.045 0.000 0.045 0.045 0.000 0.000 0.000 0.000 0.363 0.272 0.318 0.000 0.000 0.000 0.045 0.091 0.136 0.045 0.000 0.000 0.000 0.045 0.000 0.000 0.000 0.953 0.227 0.363 0.000 0.000 0.000 0.091 0.091 0.000 0.000 0.000 0.000 0.045 0.045 0.181 0.272 0.045 1.361 0.000 0.045 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.045 0.000 0.091 0.045 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.045 0.544 0.726 0.000 0.000 0.000 0.136 0.408 0.227 0.318 0.000 0.091 0.091 0.091 0.181 0.318 0.045 3.176 TOTAL HOURS OF VALID STABILITY OBSERVATIONS TOTAL HOURS OF STABILITY CLASS C TOTAL TOTAL TOTAL HOURS HOURS HOURS OF VALID WIND DIRECTION-WIND SPEED-STABILITY CLASS C OF VALID WIND DIRECTION-WIND SPEED-STABILITY OBSERVATIONS CALM 2204 70 70 2204 0

METEOROLOGICAL FACILITY:

BROWNS FERRY NUCLEAR PLANT STABILITY BASED ON DELTA-T BETWEEN 10.03 AND 89.59 METERS WIND SPEED AND DIRECTION MEASURED AT 90.29 METER LEVEL DATE PRINTED: 2014/02/25 MEAN WIND SPEED = 11.56 NOTE:

TOTALS AND SUBTOTALS ARE OBTAINED FROM UNROUNDED NUMBERS E-1 72

BROWNS FERRY NUCLEAR PLANT UNITS 1, 2, AND 3 2013 ANNUAL RADIOACTIVE EFFLUENT RELEASE REPORT JOINT PERCENTAGE FREQUENCIES OF WIND SPEED BY WIND DIRECTION FOR STABILITY CLASS D

(-1.5< DELTA T<=-0.5 C/100 M)

BROWNS FERRY NUCLEAR PLANT OCT 1, 2013 -

DEC 31, 2013 WIND DIRECTION WIND SPEED(MPH) 0.6-1.4 1.5-3.4 3.5-5.4 5.5-7.4 N

NNE NE ENE E

ESE SE SSE S

SSW SW WSW W

WNW NW NNW CALM 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 7.5-12.4 12.5-18.4 18.5-24.4 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.091 0.000 0.045 0.000 0.000 0.045 0.045 0.045 0.000 0.272 0.045 0.045 0.091 0.136 0.045 0.227 0.454 0.318 0.318 0.272 0.318 0.227 0.091 0.181 0.000 0.045 2.813 0.136 0.272 0.091 0.227 0.091 0.318 0.590 0.363 0.272 0.091 0.408 0.318 0.590 0.136 0.045 0.136 4.083 0.590 0.726 0.272 0.227 0.091 0.181 0.318 0.499 0.227 0.227 0.272 0.136 0.544 0.318 0.318 0.318 1.180 1.543 0.817 0.136 0.408 0.635 0.499 0.817 0.817 0.272 0.590 0.227 0.953 0.998 1.044 1.044 2.450 0.726

0. 045 0.000 0.227 0.408 1.134 0.817 0.862 0.318 0.136 0.136 0.272 0.726 1.407 1.361 1.044 0.454 0.000 0.000 0.000 0.136 0.907 0.091 0.091 0.000 0.000 0.000 0.045 0.091 0.998 0.590 4.446 0.181 0.000 0.000 0.000 0.000 0.000 0.272 0.000 0.136 0.091 0.000 0.000 0.000 0.000 0.000 0.045

>=24.5 TOTAL 5.626 3.766 1.316 0.726 0.862 1.906 4.174 2.995 2.722 1.316 1.724 1.044 2.541 2.495 3.857 3.539 SUBTOTAL 5.263 11.978 11.025 0.726 40.608 TOTAL HOURS OF VALID STABILITY OBSERVATIONS TOTAL HOURS OF STABILITY CLASS D TOTAL TOTAL TOTAL HOURS HOURS HOURS OF VALID WIND DIRECTION-WIND SPEED-STABILITY CLASS D OF VALID WIND DIRECTION-WIND SPEED-STABILITY OBSERVATIONS CALM 2204 895 895 2204 0

METEOROLOGICAL FACILITY:

BROWNS FERRY NUCLEAR PLANT STABILITY BASED ON DELTA-T BETWEEN 10.03 AND 89.59 METERS WIND SPEED AND DIRECTION MEASURED AT 90.29 METER LEVEL DATE PRINTED: 2014/02/25 MEAN WIND SPEED = 11.25 NOTE:

TOTALS AND SUBTOTALS ARE OBTAINED FROM UNROUNDED NUMBERS E-173

BROWNS FERRY NUCLEAR PLANT UNITS 1, 2, AND 3 2013 ANNUAL RADIOACTIVE EFFLUENT RELEASE REPORT JOINT PERCENTAGE FREQUENCIES OF WIND SPEED BY WIND DIRECTION FOR STABILITY CLASS E

(-0.5< DELTA T<= 1.5 C/100 M)

BROWNS FERRY NUCLEAR PLANT OCT 1, 2013 -

DEC 31, 2013 WIND DIRECTION WIND SPEED(MPH) 0.6-1.4 1.5-3.4 3.5-5.4 5.5-7.4 N

NNE NE ENE E

ESE SE SSE S

SSW SW WSW W

WNW NW NNW CALM 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 7.5-12.4 12.5-18.4 18.5-24.4 0.000 0.000 0.045 0.000 0.045 0.091 0.000 0.000 0.000 0.000 0.045 0.000 0.000 0.000 0.000 0.000 0.227 0.045 0.045 0.000 0.136 0.045 0.091 0.227 0.136 0.136 0.091 0.000 0.000 0.136 0.000 0.045 0.000 1.134 0.045 0.045 0.136 0.045 0.091 0.045 0.318 0.181 0.227 0.181 0.091 0.000 0.136 0.091 0.045 0.136 1.815 0.227 0.136 0.136 0.136 0.045 0.000 0.318 0.681 0.272 0.181 0.091 0.272 0.091 0.045 0.000 0.045 0.771 0.771 0.454 0.136 0.318 0.681 1.180 2.269 1.679 0.771 0.726 0.272 0.181 0.499 0.408 0.544 1.497 0.953 0.726 0.227 0.227 0.544 1.497 2.495 0.953 0.726 0.181 0.181 0.363 0.227 0.272 1.361 0.181 0.181 0.091 0.000 0.000 0.181 0.681 0.862 0.363 0.454 0.091 0.045 0.000 0.045 0.000 0.091 3.267

>=24.5 TOTAL 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.454 0.000 0.000 0.000 0.000 0.000 0.000 0.000 2.768 2.132 1.588 0.681 0.771 1.633 4.220 6.624 4.083 2.405 1.225 0.771 0.907 0.907 0.771 2.178 SUBTOTAL 2.677 11.661 12.432 0.454 33.666 TOTAL HOURS OF VALID STABILITY OBSERVATIONS TOTAL HOURS OF STABILITY CLASS E TOTAL TOTAL TOTAL HOURS HOURS HOURS OF VALID WIND DIRECTION-WIND SPEED-STABILITY CLASS E OF VALID WIND DIRECTION-WIND SPEED-STABILITY OBSERVATIONS CALM 2204 742 742 2204 0

METEOROLOGICAL FACILITY:

BROWNS FERRY NUCLEAR PLANT STABILITY BASED ON DELTA-T BETWEEN 10.03 AND 89.59 METERS WIND SPEED AND DIRECTION MEASURED AT 90.29 METER LEVEL DATE PRINTED: 2014/02/25 MEAN WIND SPEED = 12.36 NOTE:

TOTALS AND SUBTOTALS ARE OBTAINED FROM UNROUNDED NUMBERS E-174

BROWNS FERRY NUCLEAR PLANT UNITS 1, 2, AND 3 2013 ANNUAL RADIOACTIVE EFFLUENT RELEASE REPORT JOINT PERCENTAGE FREQUENCIES OF WIND SPEED BY WIND DIRECTION FOR STABILITY CLASS F

( 1.5< DELTA T<= 4.0 C/100 M)

BROWNS FERRY NUCLEAR PLANT OCT 1, 2013 -

DEC 31, 2013 WIND DIRECTION N

NNE NE ENE E

ESE SE SSE S

SSW SW WSW W

WNW NW NNW SUBTOTAL WIND SPEED(MPH) 0.6-1.4 1.5-3.4 3.5-5.4 5.5-7.4 7.5-12.4 12.5-18.4 18.5-24.4 CALM 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000

>=24.5 TOTAL 0.000 0.045 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.045 0.000 0.000 0.000 0.000 0.000 0.000 0.091 0.181 0.091 0.091 0.091 0.091 0.091 0.318 0.136 0.045 0.091 0.045 0.000 0.000 0.045 0.091 0.091 1.497 0.091 0.045 0.136 0.091 0.181 0.091 0.181 0.136 0.000 0.000 0.000 0.000 0.000 0.045 0.045 0.045 1.089 0.136 0.136 0.181 0.227 0.136 0.272 0.227 0.544 0.181 0.045 0.000 0.045 0.045 0.045 0.091 0.000 2.314 0.227 0.363 0.544 0.272 0.272 0.408 0.590 1.134 0.499 0.045 0.045 0.045 0.045 0.045 0.091 0.045 4.673 0.454 0.681 0.181 0.272 0.045 0.181 0.635 0.726 1.044 0.227 0.000 0.045 0.045 0.000 0.000 0.181 4.719 0.000 0.136 0.000 0.000 0.000 0.000 0.000 0.499 0.408 0.000 0.000 0.000 0.000 0.000 0.000 0.181 1.225 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.091 0.318 0.000 0.000 0.000 0.000 0.000 0.000 0.000 1.089 1.497 1.134 0.953 0.726 1.044 1.951 3.267 2.495 0.454 0.091 0.136 0.136 0.181 0.318 0.544 0.408 16.016 TOTAL HOURS OF VALID STABILITY OBSERVATIONS TOTAL HOURS OF STABILITY CLASS F TOTAL TOTAL TOTAL HOURS HOURS HOURS OF VALID WIND DIRECTION-WIND SPEED-STABILITY CLASS F OF VALID WIND DIRECTION-WIND SPEED-STABILITY OBSERVATIONS CALM 2204 353 353 2204 0

METEOROLOGICAL FACILITY:

BROWNS FERRY NUCLEAR PLANT STABILITY BASED ON DELTA-T BETWEEN 10.03 AND 89.59 METERS WIND SPEED AND DIRECTION MEASURED AT 90.29 METER LEVEL DATE PRINTED: 2014/02/25 MEAN WIND SPEED = 11.24 NOTE:

TOTALS AND SUBTOTALS ARE OBTAINED FROM UNROUNDED NUMBERS E-175

BROWNS FERRY NUCLEAR PLANT UNITS 1, 2, AND 3 2013 ANNUAL RADIOACTIVE EFFLUENT RELEASE REPORT JOINT PERCENTAGE FREQUENCIES OF WIND SPEED BY WIND DIRECTION FOR STABILITY CLASS G (DELTA T > 4.0 C/100 M)

BROWNS FERRY NUCLEAR PLANT OCT 1, 2013 -

DEC 31, 2013 WIND DIRECTION N

NNE NE ENE E

ESE SE SSE S

SSW SW WSW W

WNW NW NNW SUBTOTAL WIND SPEED(MPH) 0.6-1.4 1.5-3.4 3.5-5.4 5.5-7.4 7.5-12.4 12.5-18.4 18.5-24.4 CALM 0.003 0.002 0.005 0.007 0.002 0.002 0.005 0.007 0.002 0.000 0.002 0.000 0.002 0.000 0.007 0.002 0.045

>=24.5 TOTAL 0.045 0.000 0.000 0.000 0.000 0.000 0.000 0.091 0.045 0.000 0.045 0.000 0.000 0.000 0.000 0.000 0.227 0.045 0.045 0.136 0.181 0.045 0.045 0.136 0.091 0.000 0.000 0.000 0.000 0.045 0.000 0.181 0.045 0.998 0.000 0.045 0.136 0.091 0.000 0.181 0.272 0.272 0.091 0.091 0.000 0.000 0.000 0.000 0.045 0.000 1.225 0.091 0.091 0.045 0.000 0.000 0.091 0.136 0.045 0.091 0.000 0.045 0.045 0.000 0.000 0.000 0.000 0.681 0.000 0.000 0.227 0.181 0.091 0.091 0.136 0.136 0.045 0.000 0.000 0.000 0.091 0.000 0.091 0.000 1.089 0.181 0.045

0. 136 0.045 0.000 0.000 0.091 0.045 0.091 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.635 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.045 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.045 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.366 0.229 0.686 0.506 0.138 0.410 0.776 0.733 0.365 0.091 0.092 0.045 0.138 0.000 0.324 0.047 4.946 TOTAL HOURS OF VALID STABILITY OBSERVATIONS TOTAL HOURS OF STABILITY CLASS G TOTAL TOTAL TOTAL HOURS HOURS HOURS OF VALID WIND DIRECTION-WIND SPEED-STABILITY CLASS G OF VALID WIND DIRECTION-WIND SPEED-STABILITY OBSERVATIONS CALM 2204 109 109 2204 1

METEOROLOGICAL FACILITY:

BROWNS FERRY NUCLEAR PLANT STABILITY BASED ON DELTA-T BETWEEN 10.03 AND 89.59 METERS WIND SPEED AND DIRECTION MEASURED AT 90.29 METER LEVEL MEAN WIND SPEED =

6.67 NOTE:

TOTALS AND SUBTOTALS ARE OBTAINED FROM UNROUNDED NUMBERS DATE PRINTED: 2014/02/25 E-176

BROWNS FERRY NUCLEAR PLANT UNITS 1, 2, AND 3 2013 ANNUAL RADIOACTIVE EFFLUENT RELEASE REPORT ATTACHMENT 1 Deviations from ODCM Controls and Surveillance Requirements This report is to comply with Browns Ferry Nuclear Plant Offsite Dose Calculation Manual (ODCM). The ODCM requires that all deviations be reported in the Annual Radioactive Effluent Release Report.

During the reporting period, January 1, 2013 through December 31, 2013, there were no missed compensatory samples.

Liquid Radwaste or Temporary Storage Tanks During the reporting period, January 1, 2013 through December 31, 2013, BFN utilized 7 temporary outside liquid radwaste (FRAC) tanks from January through May of 2013. These tanks were used to process batch releases to the river from the excess water flooding the Radwaste basement. All releases were permitted and documented by performance of Surveillance Instruction 0-SI-4.8.A.1-1(a) in accordance with ODCM requirements (Reference PER 662887)

Changes to the Radwaste System and Changes to the Process Control Program In calendar year 2013, BFN had no permanent changes to the Radwaste System or the Process Control Program. The previous paragraph documents the Temporary Storage Tanks brought on-site due to Radwaste basement flooding from CCW leaks. These temporary tanks were removed from service in May, 2013 when the plant Liquid Radwaste Treatment System resumed all processing operations.

E-177

BROWNS FERRY NUCLEAR PLANT UNITS 1, 2, AND 3 2013 ANNUAL RADIOACTIVE EFFLUENT RELEASE REPORT ATTACHMENT 2 2013 Inoperable Radiological Effluent Instrumentation Report This report is to comply with Browns Ferry Nuclear Plant Offsite Dose Calculation Manual (ODCM) Sections 1/2.1.1 and 1/2.1.2. The ODCM requires the exertion of best efforts to return inoperable instruments to operable status within 30 days. Failure to return such instruments to an operable status within the prescribed interval requires a description in the Annual Radioactive Effluent Release Report.

During the reporting period, January 1 through December 31, 2013, there was one radioactive gaseous effluent monitoring instrument (Problem Evaluation Report (PER) 732596) out of service for greater than 30 days.

1-RM-90-251, Unit 1 Turbine Building Ventilation Effluent Radiation monitor, was declared inoperable on April 25, 2013 at 03:55 due to source check failure. A steam leak in the area was repaired to lower the background and the source was replaced. The monitor was returned to service after successful completion of the source check on June 18, 2013 at 09:15.

During the reporting period, January 1 through December 31, 2013, there was one automatic isolation valve out of service for failure to perform the required surveillance within the specified interval.

BFN ODCM requires the operation of the automatic isolation valves and discharge tank selection valves shall be checked once per 24 months. Contrary to this ODCM requirement, 3-FCV-077-0061, Radwaste Discharge Valve, was declared inoperable due to failure to perform 3-SI-4.8.A.3 within the specified time interval plus 25%. There were no liquid effluent releases made through the Unit 3 discharge lines from the time the 3-FCV-077-0061 was declared inoperable through December 31, 2013.