MONTHYEARML24032A0252024-02-0505 February 2024 NRC Initial Test Program and Operational Programs Integrated Inspection Report 05200026-2023009 ML24010A0712024-01-31031 January 2024 Exemption from Select Requirements of 10 CFR Part 73 (Security Notifications, Reports and Recordkeeping and Suspicious Activity Reporting) ML24031A6102024-01-31031 January 2024 Cyber Security Inspection Report 05200026/2024401 - Public ML24029A0592024-01-30030 January 2024 Request for Withholding Information from Public Disclosure Responses to NRC Request for Additional Information for Refueling Outage 1R24 Steam Generator Tube Inspection Report Enclosure 2, GAE-NRCD-RF-LR-000002 P-Attachment, Rev. 0 ML24016A1132024-01-30030 January 2024 Correction of Unit 1 Amendment Nos. 96 and 190 and Unit 2 Amendment Nos. 74 and 173 Adoption of Standard Technical Specifications Westinghouse Plants NL-24-0031, Inservice Inspection Program Owner'S Activity Report (OAR-1) for Outage 2R232024-01-29029 January 2024 Inservice Inspection Program Owner'S Activity Report (OAR-1) for Outage 2R23 IR 05000424/20244032024-01-26026 January 2024 Information Request for the Cyber-Security Baseline Inspection, Notification to Perform Inspection 05000424/2024403; 05000425/2024403 NL-24-0020, Plan, Unit 1 Responses to NRC Request for Additional Information for Refueling Outage 1R24 Steam Generator Tube Inspection Report2024-01-22022 January 2024 Plan, Unit 1 Responses to NRC Request for Additional Information for Refueling Outage 1R24 Steam Generator Tube Inspection Report ML23347A2092024-01-17017 January 2024 Voluntary Requests for Data, Information, And/Or Observation ML23279A0042024-01-17017 January 2024 Amendment No. 194 to Remove Combined License Appendix C NL-23-0926, Correction of Technical Specification Typographical Error2024-01-12012 January 2024 Correction of Technical Specification Typographical Error ML23341A2042024-01-12012 January 2024 Request for Additional Information Exemption Requests for Physical Barriers (EPID L-2023-LLE-0018 & L-2023-LLE-0021) ML23345A1312024-01-0303 January 2024 Withholding Letter - SNC Fleet - Physical Barriers Exemption (L-2023-LLE-0018 and L-2023-LLE-0021) ML23317A2072023-12-22022 December 2023 Issuance of Amendments 223 and 206 Regarding Revision to Technical Specifications to Adopt TSTF-339-A, Relocate Technical Specification Parameters to the COLR Consistent with WCAP-1448 ML23335A1222023-12-19019 December 2023 Safety Evaluation Regarding Implementation of Mitigating Strategies Related to Order EA-12-049 (EPID L-2023-LRQ-0002) - Letter ML23353A1702023-12-19019 December 2023 LAR-22-002, TS 3.8.3 Inverters Operating Completion Time Extension Letter ML23310A2922023-12-0707 December 2023 Issuance of Amendment for Exception to Regulatory Guide 1.163, LAR 23 007 ML23339A1812023-12-0707 December 2023 Correction Letter Regarding License Amendment Request: More Restrictive Action for Technical Specification 3.1.9 ML23338A2182023-12-0606 December 2023 Project Manager Reassignment NL-23-0878, Request for Exemption from Security Event Notification Implementation2023-11-29029 November 2023 Request for Exemption from Security Event Notification Implementation ML23289A1632023-11-28028 November 2023 Letter and Amendment 195 and 192 LAR-23-006R1 TS 3.1.9 More Restrictive Action NL-23-0827, Response to Requests for Additional Information for a License Amendment Request and a Proposed Alternative Related to TS 3.4.142023-11-17017 November 2023 Response to Requests for Additional Information for a License Amendment Request and a Proposed Alternative Related to TS 3.4.14 ML23318A4582023-11-14014 November 2023 Integrated Inspection Report 05200025/2023003 ML23312A3502023-11-14014 November 2023 Integrated Inspection Report 05200026/2023003 ML23306A3552023-11-0808 November 2023 NRC Initial Test Program and Operational Programs Integrated Inspection Report 052000/262023008 ML23268A0572023-11-0707 November 2023 Issuance of Amendments 194 & 191 Request for License Amendment Relocation of Technical Specification 3.7.9, Spent Fuel Pool Makeup Water Sources (LAR-23-003) IR 05000424/20234022023-11-0606 November 2023 Security Baseline Inspection Report 05000424/2023402 and 05000425/2023402 IR 05000424/20230032023-10-27027 October 2023 Integrated Inspection Report 05000424/2023003 and 05000425/2023003 ML23291A1512023-10-18018 October 2023 Information Request for the Cyber Security Baseline Inspection, Notification to Perform Inspection 0520026/2024401 ML23263A9852023-10-12012 October 2023 Issuance of Amendments Nos. 221 and 204, Regarding Technical Specification 5.5.11.C, Acceptance Criteria for Charcoal Filter Testing ML23283A0472023-10-0808 October 2023 Neop Letter Dated October 8, 2023 - Vogtle 3 & 4 - TS 3.7.6 License Amendment Request NL-23-0750, Response to Second Request for Additional Information Regarding License Amendment Request: Technical Specification Revision to Adopt TSTF-339-A, Relocate Technical Specification Parameters to the Colr2023-10-0404 October 2023 Response to Second Request for Additional Information Regarding License Amendment Request: Technical Specification Revision to Adopt TSTF-339-A, Relocate Technical Specification Parameters to the Colr NL-23-0745, Refueling Outage 1R24 Steam Generator Tube Inspection Report2023-09-22022 September 2023 Refueling Outage 1R24 Steam Generator Tube Inspection Report ML23254A2032023-09-13013 September 2023 Initial Test Program and Operational Programs Inspection Report 05200025/2023013 ML23241B0212023-09-12012 September 2023 Review of Quality Assurance Topical Report ML23234A2352023-09-0808 September 2023 Request for Withholding Information from Public Disclosure Notification of Full Compliance of Required Action for NRC Order EA-12-049 Mitigation Strategies for Beyond-Design-Basis External Events IR 05000424/20230912023-09-0505 September 2023 Plan Units 1 and 2 - NRC Investigation Report 2-2022-006 and Notice of Violation - NRC Inspection Report 05000424/2023091 and 05000425/2023091 ML23234A3002023-09-0101 September 2023 NRC Integrated Inspection Report 05200026/2023003 ML23243A0092023-08-31031 August 2023 Updated Inspection Plan for Vogtle Electric Generating Plant, Units 3 & 4 (Report 05200025 2023005 & 05200026 2023005) NL-23-0695, Response to Round 2 Request for Additional Information Regarding License Amendment Request for Technical Specification 3.8.3, Inverters Operating, Completion Time Extension (LAR-22-002S2)2023-08-31031 August 2023 Response to Round 2 Request for Additional Information Regarding License Amendment Request for Technical Specification 3.8.3, Inverters Operating, Completion Time Extension (LAR-22-002S2) ML23243B0252023-08-30030 August 2023 Exam Corporate Notification Letter (210 Day) IR 05000424/20230052023-08-29029 August 2023 Updated Inspection Plan for Vogtle Electric Generating Plant, Units 1 & 2 - Report 05000424/2023005 and 05000425/2023005 NL-23-0666, License Amendment Request: Remove Combined License Appendix C (LAR 23-008)2023-08-28028 August 2023 License Amendment Request: Remove Combined License Appendix C (LAR 23-008) 2024-02-05
[Table view] |
Text
April 8, 2014 Mr. Roy Linthicum PWR Owners Group Risk Management Chairman 4300 Windfield Road Warrenville, IL 60555
Dear Mr. Linthicum,
The purpose of this letter is to formally request the Pressurized Water Reactor Owners Group (PWROG) to perform peer reviews of the U.S. Nuclear Regulatory Commission (NRC) Level 3 Site Probabilistic Risk Assessment for the Vogtle site (the L3PRA project). The Vogtle site contains two Westinghouse 4-loop PWRs. The L3PRA project involves a Level 3 analysis that addresses internal and external hazards, all plant operating modes, and the risk from both reactors, both spent fuel pools, and dry cask storage. The Quality Assurance Plan developed for this project specifies the need for peer reviews in accordance with the ASME/ANS PRA standards.
We have previously discussed these peer reviews with you in public meetings on June 4, 2013 (ADAMS Accession Number ML13241A127), and January 27, 2014 (ADAMS Accession Number ML14043A364), as well as in several phone calls and e-mail exchanges. The following summarizes our preferences and understanding of the process to be followed in performing the peer reviews.
The NRC prefers to have peer reviews performed at various points throughout the study, as opposed to a single peer review at the end of the project. This preference is because (1) it will allow any needed corrections early and, therefore, minimize the amount of any re-work, and (2) a single comprehensive peer review would be difficult considering the different types of expertise needed to cover the entire scope of the project. It is our understanding that the PWROG has budgeted for four peer reviews this calendar year. As discussed in the meeting on January 27, 2014, we are now anticipating that the L3PRA project schedule will only support the following three peer reviews this calendar year:
- Level 1 internal events, and internal flooding (excluding LERF) for the week of July 21, 2014. This will be a focused scope peer review.
- Level 2 peer review the week September 29, 2014. It is anticipated that this will involve a full scope peer review.
- High winds and other hazards peer review the week of either November 3 or November 10, 2014. This will probably require only a couple of days instead of a full week.
R. Linthicum Again, as discussed on January 27, 2014, instead of a fourth peer review, we would like to work with the PWROG to develop review criteria for two of the areas of the L3PRA project for which no PRA standard (either draft or final) currently exists (i.e., dry cask storage and the spent fuel pool). We would like to have these criteria developed by December 2014.
We are looking for the PWROG to lead each peer review, and therefore, provide the facilitator and produce the peer review report. For each peer review, the NRC will identify one or two experienced PRA analysts (e.g., Regional Senior Reactor Analysts) that will supplement the peer review team to be assembled by the PWROG. As part of documenting our request for each peer review, we will include the specific experience and capabilities of the NRC-proposed reviewers. Please see the enclosure (Table 1) for the official request for the first peer review.
We will provide a similar table for the next peer reviews, as discussed above.
We greatly appreciate the PWROGs support in this effort. The peer review is a critical element in ensuring the technical quality and traceability of the work of the L3PRA project. We look forward to working with the PWROG on these peer reviews and, hopefully, others in the future, so that the entire scope of the NRC L3PRA project is fully peer reviewed. If you have any questions, please do not hesitate to contact Mary Drouin of my staff at (301) 251-7574.
Sincerely,
/RA/
Richard P. Correia, Director Division of Risk Analysis Office of Nuclear Regulatory Research
ML14094A344 OFFICE RES/DRA/PRB RES/DRA/PRAB BC: RES/DRA/PRAB D: RES/DRA NAME M. Drouin A. Kuritzky K. Coyne R. Correia DATE 4/4/14 4/7/14 4/7/14 4/8/14