ENCLOSURE SEMIANNUAL RADIOACTIVE EFFLUENT RELEASE REPORT*

6.9.1.8 Routine radioactive effluent release reports covering the operation of the unit during the previous 6 months of operation shall be submitted within 60 days after January 1 and July 1 of each year.

6.9.1.9 The radioactive effluent release reports shall include a summary of the quantities of radioactive liquid and gaseous effluents and solid waste released from the unit as outlined in Regulatory Guide 1.21, "Measuring Evaluating, and Reporting Radioactivity in Solid Wastes and Releases of Radioactive Materials in Liquid and Gaseous Effluents from Light-Water-Cooled Nuclear Power Plants,"

Revision 1, June 1974, with data summarized on a quarterly basis following the format of Appendix B thereof.

The radioactive effluent release report to be submitted 60 days after January 1 of each year shall include an annual summary of hourly meteorological data collected over the previous year.

This annual summary may be either in the form of an hour-by-hour listing of wind speed, wind direction, and atmospheric stability, and precipitation (if measured) on magnetic tape, or in the form of joint frequency distributions of wind speed, wind direction, and atmospheric stability.**

This same report shall include an assessment of the radiation doses due to the radioactive liquid and gaseous effluents released from the unit or station during the previous calendar year.

This same report shall also include an assessment of the radiation doses from radioactive liquid and gaseous effluents to MEMBERS OF THE PUBLIC due to their activities inside the SITE BOUNDARY during the report period. All assumptions used in making these assessments (i.e., specific activity, exposure time and location) shall be included in these reports.

The meteorological conditions concurrent with the time of release of radioactive materials in gaseous effluents (as determined by sampling frequency and measurement) shall be used for determining the gaseous pathway doses.

The assessment of radiation doses shall be performed in accordance with the OFFSITE DOSE CALCULATION MANUAL (ODCM).

A single submittal may be made for multiple unit station. The submittal should combine those sections that are common to all units at the station; however, for units with separate radwaste systems, the submittal shall specify the releases of radioactive material from each unit.

In lieu of submission with the first half year Radioactive Effluent Release Report, the licensee has the option of retaining this summary of required meteorological data on site in a file that shall be provided to the NRC upon request.

8508060170 8 50731 PDR ADOCK 05000206 PDR I

SAN ONOFRE -

UNIT 1

0 0

The radioactive effluent release report to be submitted 60 days after January 1 of each year shall also include an assessment of radiation doses to the likely most exposed MEMBER OF THE PUBLIC from reactor releases and other nearby uranium fuel cycle sources (including doses from primary effluent pathways and direct radiation) for the previous calendar year to show conformance with 40 CFR 190, Environmental Radiation Protection Standards for Nuclear Power Operation. Acceptable methods for calculating the dose contribution from liquid and gaseous effluents are given in the OFFSITE DOSE CALCULATION MANUAL (00CM).

The radioactive effluent release reports shall include the following information for each type of solid waste shipped offsite during the report period:

a.

Container volume,

b.

Total curie quantity (specify whether determined by measurement or estimate),

c.

Principal radionuclides (specify whether determined by measurement or estimate),

d.

Type of waste (e.g., dewatered spent resin, compacted dry waste, evaporator bottom),

e.

Type of container (e.g., LSA, Type A, Type B, Large Quantity), and

f.

Solidification agent (e.g., cement, urea formaldehyde).

The radioactive release reports shall include unplanned releases from the site to UNRESTRICTED AREAS of radioactive material in gaseous and liquid effluents on a quarterly basis.

The Radioactive Effluent Release Reports shall include any changes made to the PROCESS CONTROL PROGRAM (PCP), to the OFFSITE DOSE CALCULATION MANUAL (ODCM), or major changes to radioactive waste treatment systems during the reporting period.

MONTHLY OPERATING REPORT 6.9.1.10 Routine reports of operating statistics and shutdown experience, including documentation of all challenges to pressurizer safety and relief valves, shall be submitted on a monthly basis to the Director, Office of Resource Management, U.S. Nuclear Regulatory Commission, Washington, D.C., 20555, with a copy to the Regional Administrator of the Regional Office of the NRC, no later than the 15th of each month following the calendar month covered by the report.

SAN ONOFRE - UNIT 1

SPECIAL REPORTS 6.9.2 Special reports shall be submitted to the NRC Regional Administrator, unless otherwise indicated, within the time period specified for each report.

SAN ONOFRE -

UNIT 1

6.15 MAJOR CHANGES TO RADIOACTIVE WASTE TREATMENT SYSTEMS* (Liquid, Gaseous and Solid) 6.15.1 Licensee-initiated major changes to the radioactive waste treatment systems (liquid, gaseous and solid):

1. Shall be reported to the Commission in the Semiannual Effluent Release Report for the period in which the change(s) was made effective pursuant to 6.5.2.9.

The discussion of each change shall contain:

a.

A summary of the evaluation that led to the determination that the change could be made in accordance with 10 CFR 50.59;

b.

Sufficient detailed information to totally support the reason for the change without benefit of additional or supplemental information;

c.

A detailed description of the equipment, components and processes involved and the interfaces with other plant systems;

d.

An evaluation of the change which shows the predicted releases of radioactive materials in liquid and gaseous effluents and/or quantity of solid waste that differ from those previously predicted in the licensee application and amendments thereto;

e.

An evaluation of the change which shows the expected maximum exposures to an individual in the UNRESTRICTED AREA and to the general population that differ from those previously estimated in the licensee application and amendments thereto;

f.

A comparison of the predicted releases of radioactive materials, in liquid and gaseous effluents and in solid waste, to the actual releases for the period prior to when the changes are to be made;

g.

An estimate of the exposure to plant operating personnel as a result of the change; and

h.

Documentation of the fact that the change was reviewed and found acceptable pursuant to 6.5.2.9.

2. Shall become effective upon review and approval pursuant to 6.5.2.9.

Licensees may choose to submit the information called for in this Specification as part of the annual FSAR update.

SAN ONOFRE -

UNIT 1