NL-13-089, Indian Point, Unit 3, Enclosure to NL-13-089, Seismic Walkdown Report Update, Part 3 of 6

From kanterella
(Redirected from ML13176A007)
Jump to navigation Jump to search
Indian Point, Unit 3, Enclosure to NL-13-089, Seismic Walkdown Report Update, Part 3 of 6
ML13176A007
Person / Time
Site: Indian Point Entergy icon.png
Issue date: 05/24/2013
From: Lo K
Entergy Nuclear Northeast
To:
Office of Nuclear Reactor Regulation
References
NL-13-089
Download: ML13176A007 (154)


Text

Engineering Report No. IP-RPT-12-00039, Rev. 0, Page D-39 of 192 ATTACHMENT 9.7 AREA WALK-BY CHECKLIST Sheet I of 7 IP3 Status: YO- NEI UD--Area Walk-By Checklist (AWC) AWC-010 Location:

Bldg. IS Floor El. 15'-0" Room, Area'SWEL Components:

SWELl-030, 031 Instructions for Completing Checklist This checklist may be used to document the results of the Area Walk-By near one or more SWEL items. The space below each of the following questions may be used to record the results of judgments and findings.Additional space is provided at the end of this checklist for documenting other comments.1. Does anchorage of equipment in the area appear to be free of potentially adverse seismic conditions (if visible without necessarily opening cabinets)?

Panel (PID 08219) adjacent to the door: Unistrut legs corroded and broken at the base (see attach photos). The toe plate at the floor penetration between the Unistrut legs is loose and is not protecting the opening (see attach photo).Service Water Pumps Annubars has rotted out at the base. The panel lacks of lateral restraints and is free to displace laterally.

Piping grout penetration protection was found cracked and chipped at various locations allowing water seepage (see photos).Outer section of the grout, external o the base plate, for SWP 34 is cracked and missing. This does not affect the integrity of the support of the pump.The above conditions are addressed by CR-IP3-2012-03166.

2. Does anchorage of equipment in the area appear to be free of significant degraded conditions?

YO N[ UD- N/A[-]YDI NO U- N/A-See above.I If the room in which the SWEL item is located is very large (e.g., Turbine Hall), the area selected should be described.

This selected area should be based on judgment, e.g., on the order of about 35 feet from the SWEL item.EN-DC-168 REV 0 Engineering Report No. IP-RPT-12-00039, Rev. 0, Page D-40 of 192 ATTACHMENT 9.7 AREA WALK-BY CHECKLIST Sheet 2 of 7 1P3 Status: YU NDI UID Area Walk-By Checklist (AWC) AWC-010 Location:

Bldg. IS Floor El. 15'-0" Room, Area'SWEL Components:

SWELl-030, 031 3. Based on a visual inspection from the floor, do the cable/conduit YD- NE u[:] N/AD raceways and HVAC ducting appear to be free of potentially adverse seismic conditions (e.g., condition of supports is adequate and fill conditions of cable trays appear to be inside acceptable limits)?Floor grating behind the electrical panels is not fixed to the structural steel and could displace laterally.

In addition, this grating also serves as a support for conduits at the level below. Displacement of the grating would affect the support for the conduits.

This condition is addressed by CR-IP3-2012-03166.

4. Does it appear that the area is free of potentially adverse seismic spatial interactions with other equipment in the area (e.g., ceiling tiles and lighting)?

Yes, it appears that the area is free of potentially adverse seismic spatial interactions with other equipment in the area.5. Does it appear that the area is free of potentially adverse seismic interactions that could cause flooding or spray in the area?Yes, it appears that the area is free of potentially adverse seismic interactions that could cause flooding or spray in the area.6. Does it appear that the area is free of potentially adverse seismic interactions that could cause a fire in the area?Yes, it appears that the area is free of potentially adverse seismic interactions that could cause a fire in the area.7. Does it appear that the area is free of potentially adverse seismic interactions associated with housekeeping practices, storage of portable equipment, and temporary installations (e.g., scaffolding, lead shielding)?

Observed a phone and a tool box resting on the web of a beam wall.The phone and the tool box are restrained by the two beam flanges.This is judged acceptable.

Observed a loose scaffold pole (on the floor) beneath a wall beam.During a seismic event the pole may act as a missile and strike nearby equipment.

This is addressed by CR-IP3-2012-03166.

YN NEI uD- N/A--YE NI UD N/AD YN NDI UD- N/AD1 YDN NNDC- N/ADE EN-DC-168 REV 0 Engineering Report No. IP-RPT-12-00039, Rev. 0, Page D-41 of 192 ATTACHMENT 9.7 AREA WALK-BY CHECKLIST Sheet 3 of 7 IP3 Status: Y[ NL-I UD--Area Walk-By Checklist (AWC) AWC-010 Location:

Bldg. IS Floor El. 15'-0" Room, Area'SWEL Components:

SWELI-030, 031 8. Have you looked for and found no other seismic conditions that could Y-I NE U-I adversely affect the safety functions of the equipment in the area?Ceiling of the area consists of grating which, if not attached to the support steel could fall and impact the equipment.

It was determined that the grating is adequately supported and would not be displaced by a seismic event.Electric Heat Trace Cabinet 31 has abraded cables at the top of the cabinet. The back of the cabinet is mildly corroded at the back/bottom.

A box of bulbs is loose on the inside of the cabinet. An unsecured tag is on a shelf in the cabinet. A brown spot on the back of the cabinet may be the result of a buming effect due to high temperature.

Electrical needs to investigate.

The cabinet is addressed by CR-IP3-2012-03166.

Comments (Additional pages may be added as necessary) 4 ,'a k 1 Evaluated by: Paul Huebsch Date: 10/12/2012 Maggie Farah 10/12/2012 Kai Lo Ic2 10/12/2012 EN-DC-168 REV 0 Engineering Report No IP-RPT-12-00039.

Rev 0 Page D-42 of 192 ATTACHMENT 9.7 AREA WALK-BY CHECKLIST Sheet 4 of 7 IP3 Status: Y[ NFI- U-]Area Walk-By Checklist (AWC) AWC-010 Location:

Bldg. IS Floor El. 15*-03 Room, Area'SWEL Components:

Photoaranhs SWELl-030.

031 MULM. LUIIUUIU dfIU U!K011 II lIIISUU flUdf UUU()O!and a loose pipe protection cover between the Unistrut legs EN-DC-168 REV 0 Engineering Report No IP-RPT-12-00039.

Rev 0. Page D-43 of 192 ATTACHMENT 9.7 AREA WALK-By CHECKLIST Sheet 5 of 7 IP3 Status: YE ND ULIJ Area Walk-By Checklist (AWC) AWC-010 Location Bldg. IS Floor El. 15'-0" Room, Area'SWEL Components:

SWELl-030, 031 EN-DC-168 REV 0 Engineering Report No IP-RPT-12-00039, Rev 0. Page D-44 of 192 ATTACHMENT 9.7 AREA WALK-BY CHECKLIST Sheet 6 of 7 IP3 Status: YLE NFi UO Area Walk-By Checklist (AWC) AWC-010 Location:

Bldg. IS Floor El. 15'-0" Room, Area'SWEL Components:

SWELI-030, 031 III I mute: uracKea grout penetration protection nroxe: LracKea grout penetration protection EN-DC-168 REV 0 Engineering Report No IP-RPT-12-00039, Rev 0, Page D-45 of 192 ATTACHMENT 9.7 AREA WALK-BY CHECKLIST Sheet 7 of 7 IP3 Status: YfZ ND UEi Area Walk-By Checklist (AWC) AWC-010 Location:

Bldg. IS Floor El. 15-0" Room, Area'SWEL Components:

SWELI-030, 031 Note: Cracked and chipped grout penetration Note: Cracked and chipped grout penetration protection protection EN-DC-168 REV 0 Engineering Report No. IP-RPT-12-00039, Rev. 0, Page D-46 of 192 ATTACHMENT 9.7 AREA WALK-BY CHECKLIST Sheet 1 of 5 IP3 Status: YX NF UD Area Walk-By Checklist (AWC) AWC-011 Location:

Bldg. YD Floor El. 80'-0" Room, Area 1 SWEL Components:

SWELl-094 Instructions for Completing Checklist This checklist may be used to document the results of the Area Walk-By near one or more SWEL items. The space below each of the following questions may be used to record the results of judgments and findings.Additional space is provided at the end of this checklist for documenting other comments.1. Does anchorage of equipment in the area appear to be free of potentially adverse seismic conditions (if visible without necessarily opening cabinets)?

Yes, anchorage of equipment in the area appears to be free of potentially adverse seismic conditions.

YE NO UD N/AD 2. Does anchorage of equipment in the area appear to be free of significant degraded conditions?

Observed mild rusting on anchorage for conduit around RWST-31. This is insignificant and judged to be acceptable.

YE NI U-I N/AD 3. Based on a visual inspection from the floor, do the cable/conduit raceways and HVAC ducting appear to be free of potentially adverse seismic conditions (e.g., condition of supports is adequate and fill conditions of cable trays appear to be inside acceptable limits)?Since the refuel water storage tank is in the yard. The above question does not apply.4. Does it appear that the area is free of potentially adverse seismic spatial interactions with other equipment in the area (e.g., ceiling tiles and lighting)?

YD NDI UD N/A[Z Y[ NDI uD N/AD Yes, it appears that the area is free of potentially adverse seismic spatial interactions with other equipment in the area.If the room in which the SWEL item is located is very large (e.g., Turbine Hall), the area selected should be described.

This selected area should be based on judgment, e.g., on the order of about 35 feet frlom the SWEL item.EN-DC-168 REV 0 Engineering Report No. IP-RPT-12-00039, Rev. 0, Page D-47 of 192 ATTACHMENT 9.7 AREA WALK-BY CHECKLIST Sheet 2 of 5 1P3 Status: Y[ NDI UD-Area Walk-By Checklist (AWC) AWC-011 Location:

Bldg. YD Floor El. 80'-0" Room, Area 1 SWEL Components:

SWELl-094 5. Does it appear that the area is free of potentially adverse seismic YE NDI UD- N/AD interactions that could cause flooding or spray in the area?Yes, it appears that the area is free of potentially adverse seismic interactions that could cause flooding or spray in the area.6. Does it appear that the area is free of potentially adverse seismic interactions that could cause a fire in the area?Yes, it appears that the area is free of potentially adverse seismic interactions that could cause a fire in the area.YZ NDI UD N/A-7. Does it appear that the area is free of potentially adverse seismic interactions associated with housekeeping practices, storage of portable equipment, and temporary installations (e.g., scaffolding, lead shielding)?

Observed a loose chain and a Unistrut on top of the RWST-31 foundation (see attached photos).Observed a rock resting on the RWST-31 stiffener ring (see attached photo).Multiple piping insulation connections have been dislodged and held together by tape (see attached photos).The above is addressed by CR-IP3-2012-03213.

YO NZ- uD N/AD1 8. Have you looked for and found no other seismic conditions that could YE ND UD-adversely affect the safety functions of the equipment in the area?Yes, we have looked for and found no other seismic conditions that could adversely affect the safety functions of the equipment in the area.EN-DC-168 REV 0 Engineering Report No. IP-RPT-12-00039, Rev, 0, Page D-48 of 192 ATTACHMENT 9.7 Sheet 3 of 5 Area Walk-By Checklist (AWC) AWC-011 Location:

Bldg. YD Floor El. 80'-0" Room, Area'SWEL Components:

SWELl -094 Comments (Additional pages may be added as necessary)

AREA WALK-BY CHECKLIST IP3 Status: YE NEI U-Evaluated by: Paul Huebsch ' ' Date: 10/12/2012 Magqie Farah C Date: 10/12/2012 Kai Lo 6 , Date: 10/12/2012 EN-DC-1 68 REV 0 Engineering Report No IP-RPT-12-00039 Rev 0. Page D-49 of 192 ATTACHMENT 9.7 AREA WALK-BY CHECKLIST Sheet 4 of 5 IP3 Status: YE[ N[i Area Walk-By Checklist (AWC) AWC-01 1 Location:

Bldg. YD Floor El. 80'-0" Room, Area 1 SWEL Components:

SWELl -094 Photographs PLU. UI; fUS11rly Uft UIV 1drK ring.Note: Piping insulation connection held with tape.EN-DC-168 REV 0 Engineering Report No IP-RPT-12-00039, Rev 0. Page D-50 of 192 ATTACHMENT 9.7 AREA WALK-BY CHECKLIST Sheet 5 of 5 Area Walk-By Checklist (AWC) AWC-01 1 Location:

Bldg. YD Floor El. 80'-0" Room, Area'SWEL Components:

SWELl-094 IP3 Status: YE] NFI UE]EN-DC-168 REV 0 Engineering Report No. IP-RPT-12-00039, Rev. 0, Page D-51 of 192 ATTACHMENT 9.7 AREA WALK-BY CHECKLIST Sheet I of 5 1P3 Status: YE NEI UD-Area Walk-By Checklist (AWC) AWC-012 Location:

Bldg. AFB Floor El. 18'-6" Room, Area 1 SWEL Components:

SWELl -040, 022, 023, 086, 005, 081 Instructions for Completing Checklist This checklist may be used to document the results of the Area Walk-By near one or more SWEL items. The space below each of the following questions may be used to record the results of judgments and findings.Additional space is provided at the end of this checklist for documenting other comments.1. Does anchorage of equipment in the area appear to be free of potentially adverse seismic conditions (if visible without necessarily opening cabinets)?

Yes, anchorage of equipment in the area appears to be free of potentially adverse seismic conditions.

2. Does anchorage of equipment in the area appear to be free of significant degraded conditions?

Yes, anchorage of equipment in the area appears to be free of significant degraded conditions.

3. Based on a visual inspection from the floor, do the cable/conduit raceways and HVAC ducting appear to be free of potentially adverse seismic conditions (e.g., condition of supports is adequate and fill conditions of cable trays appear to be inside acceptable limits)?A pipe support immediately adjacent to Appendix R cabinet ERB-47-ABFP that is attached to the ceiling has a base plate with six holes but only four bolts are installed (see attached photo). CR-IP3-2012-03580 was written to evaluate this condition.

LB-17 evaluates this condition.

4. Does it appear that the area is free of potentially adverse seismic spatial interactions with other equipment in the area (e.g., ceiling tiles and lighting)?

YE ND- ULI N/A--YN NEI U- N/AD YDI NE UED N/AD-YD- NE UD- N/A[D-]Fluorescent bulb adjacent to 32 ABFP needs to be secured to light fixture. During a seismic event the bulb may become loose and strike nearby equipment.

This is documented in CR-IP3-2012-03462.

'If the room in which the SWEL item is located is veri, large (e.g., Turbine Hall), the area selected should be described.

This selected area should be based on judgment, e.g., on the order of about 35 feet from the SWEL item.EN-DC-168 REV 0 Engineering Report No. IP-RPT-12-00039, Rev. 0, Page D-52 of 192 ATTACHMENT 9.7 AREA WALK-BY CHECKLIST Sheet 2 of 5 IP3 Status: YE NDI UID Area Walk-By Checklist (AWC) AWC-012 Location:

Bldg. AFB Floor El. 18'-6" Room, Area 1 SWEL Components:

SWELl -040, 022, 023, 086, 005, 081 5. Does it appear that the area is free of potentially adverse seismic YDI NE UD- N/AD-interactions that could cause flooding or spray in the area?Branch risers from the main fire water line are threaded pipe and pass in close proximity (estimate 1" +/-) to large conduit. The conduit is well supported and the fire water line would have to move axially to cause an impact. The vertical rise of the pipe is very short so it is judged that the impact will not occur. See photos.The sprinkler heads are at one location also in close proximity (estimate less than one inch) of adjacent conduit and could interact with the adjacent conduit in a seismic event. See photo.LB-18 was generated to evaluate this condition.

6. Does it appear that the area is free of potentially adverse seismic interactions that could cause a fire in the area?The area is free of potentially adverse seismic interactions which could cause a fire in the area.Y!Z NEI u-- N/AD-7. Does it appear that the area is free of potentially adverse seismic interactions associated with housekeeping practices, storage of portable equipment, and temporary installations (e.g., scaffolding, lead shielding)?

Scaffolding is in the area. However the green tag indicates that evaluation by Engineering has been performed.

The work area has a bucket on the floor which is not restrained and a tool box which is not secured. This is documented in CR-IP3-2012-03462.YO NE u-- N/AD1 8. Have you looked for and found no other seismic conditions that could YE NDI UD-adversely affect the safety functions of the equipment in the area?Yes, we have looked for and found no other seismic conditions that could adversely affect the safety functions of the equipment in the area.EN-DC-1 68 REV 0 Engineering Report No. IP-RPT-12-00039, Rev. 0, Page D-53 of 192 ATTACHMENT 9.7 Sheet 3 of 5 Area Walk-By Checklist (AWC) AWC-012 Location:

Bldg. AFB Floor El. 18'-6" Room, Area 1 SWEL Components:

SWELl -040, 022, 023, 086, 005, 081 Comments (Additional pages may be added as necessary)

References:

LB-17 LB-18 AREA WALK-BY CHECKLIST IP3 Status: YU NFi U--Evaluated by: Paul Huebsch .Date: 10/12/2012 Maggie Farah 10/12/2012 EN-DC-168 REV 0 Engineering Report No IP-RPT-12-00039.

Rev 0 Page D-54 of 192 ATTACHMENT 9.7 AREA WALK-BY CHECKLIST Sheet 4 of 5 IP3 Status: YO ND ULI Area Walk-By Checklist (AWC) AWC-012 Location:

Bldg. AFB Floor El. 18'-6" Room, Area'SWEL Components:

Photographs SWELl -040, 022. 023. 086. 005. 081 EN-DC-168 REV 0 Engineering Report No IP-RPT-12-00039, Rev. 0. Page D-55 of 192 ATTACHMENT 9.7 AREA WALK-BY CHECKLIST Sheet 5 of 5 IP3 Status: YZ NFI ULI Area Walk-By Checklist (AWC) AWC-012 Location:

Bldg. AFB Floor El. 18'-6" Room, Area 1 SWEL Components:

SWELl -040, 022, 023, 086, 005, 081 1 1 1 _ _Note: Fire waterline in close proximity to a conduit.N Sprinkler head in close proximity to adjacent conduit.EN-DC-168 REV 0 Engineering Report No. IP-RPT-12-00039, Rev. 0, Page D-56 of 192 ATTACHMENT 9.7 AREA WALK-BY CHECKLIST Sheet I of 8 IP3 Status: YO Nr- U-Area Walk-By Checklist (AWC) AWC-013 Location:

BIdg.AFB FloorEl. 32'-6" Room,Area 1 SWEL Components:

SWELl-048, 035 Instructions for Completing Checklist This checklist may be used to document the results of the Area Walk-By near one or more SWEL items. The space below each of the following questions may be used to record the results of judgments and findings.Additional space is provided at the end of this checklist for documenting other comments.1. Does anchorage of equipment in the area appear to be free of potentially adverse seismic conditions (if visible without necessarily opening cabinets)?

Grout at 38 Chemical Feed Pump is chipped off exposing one anchor bolt under the base plate. OK by judgment but should be repaired.

CR-IP3-2012-03627 is written to address this problem.2. Does anchorage of equipment in the area appear to be free of significant degraded conditions?

Yes, equipment anchorages are free of significant degraded conditions.

3. Based on a visual inspection from the floor, do the cable/conduit raceways and HVAC ducting appear to be free of potentially adverse seismic conditions (e.g., condition of supports is adequate and fill conditions of cable trays appear to be inside acceptable limits)?Y[ NEI u-- N/AD]YE[ NEI uZI N/Ar-Y[:- NO UDI N/AD-The 1" chemical feed piping around Door 218 has 18 feet of unsupported span length. See attached photo. CR IP3-2012-03627 was written to address this condition.

The pipe is a non-safety related pipe.If the pipe were to collapse, it would hang at the top of the monorail.The pipe is on top of a door and there is no equipment near the door.Chemical feed line pipe insulation at CF-44-2 is in contact with the support frame and heater. This is not considered a problem since the insulation around the pipe has a substantially greater diameter than the encased pipe and the insulation would be expected to flex and relieve any force that would be exerted on the pipe.Insulation at CF-133 and Cf-44-4 is missing.If the room in which the SWEL item is located is very large (e.g., Turbine Hall), the area selected should be described.

This selected area should be based on judgment, e.g., on the order of about 35 feet from the SWEL item.EN-DC-168 REV 0 Engineering Report No. IP-RPT-12-00039, Rev. 0, Page D-57 of 192 ATTACHMENT 9.7 AREA WALK-BY CHECKLIST Sheet 2 of 8 IP3 Status: YLZ ND I UD-Area Walk-By Checklist (AWC) AWC-013 Location:

Bldg.AFB Floor El. 32'-6" Room, Area 1 SWEL Components:

SWELl-048, 035 4. Does it appear that the area is free of potentially adverse seismic spatial interactions with other equipment in the area (e.g., ceiling tiles and lighting)?

Yes, the area is free of potentially adverse seismic spatial interactions with other equipment in the area.YfZ ND UID- N/AD 5. Does it appear that the area is free of potentially adverse seismic interactions that could cause flooding or spray in the area?Yes, the area is free of potentially adverse seismic interactions that could cause flooding or spray in the area.YE NDI UDi N/A[D 6. Does it appear that the area is free of potentially adverse seismic interactions that could cause a fire in the area?Yes, the area is free of potentially adverse seismic interactions that could cause a fire in the area.YE NDI ULD N/AD-7. Does it appear that the area is free of potentially adverse seismic interactions associated with housekeeping practices, storage of portable equipment, and temporary installations (e.g., scaffolding, lead shielding)?

Yes, the area is free of potentially adverse seismic interactions associated with housekeeping practices.

A pair of used gloves was found next to the 33 Chemical Feed Tank.See photo.Unsecured stool found stored next to nitrogen tank. Not judged a serious concern because of the light weight of the stool but should be addressed as a matter of good seismic housekeeping.

CR IP3-2012-03627 was written to address this condition.

Fluorescent bulbs in the area need to be restrained.

Y[ NDI UD- N/AD EN-DC-168 REV 0 Engineering Report No. IP-RPT-12-00039, Rev. 0, Page D-58 of 192 ATTACHMENT 9.7 AREA WALK-By CHECKLIST Sheet 3 of 8 IP3 Status: YE NEI UD Area Walk-By Checklist (AWC) AWC-013 Location:

Bldg.AFB Floor El. 32'-6" Room, Area 1 SWEL Components:

SWELl-048, 035 8. Have you looked for and found no other seismic conditions that could YE ND U-adversely affect the safety functions of the equipment in the area?Yes, we have looked for and found no other seismic conditions that could adversely affect the safety functions of the equipment in the area.Comments (Additional pages may be added as necessary)

Evaluated by: Stephen Yuan Date: 10/16/2012 Paul Huebsch ( 1011612012 EN-DC-168 REV 0 Engineering Report No. IP-RPT-12-00039.

Rev 0. Page D-59 of 192 ATTACHMENT 9.7 AREA WALK-BY CHECKLIST Sheet 4 of 8 IP3 Status: Y[J NF UD Area Walk-By Checklist (AWC) AWC-013 Location:

Bldg.AFB Floor El. 32-6" Room, Area 1 SWEL Components:

SWELl-048, 035 Photographs Note: U(ed gloves on floor EN-DC-168 REV 0 Engineering Report No. IP-RPT-12-00039.

Rev 0, Page D-60 of 192 ATTACHMENT 9.7 AREA WALK-BY CHECKLIST Sheet 5 of 8 IP3 Status: YW ND UZI Area Walk-By Checklist (AWC) AWC-013 Location:

Bldg. AFB Floor El. 32'-6" Room, Area'SWEL Components:

SWELl-048, 035 Photographs EN-DC-168 REV 0 Engineering Report No IP-RPT-12-00039.

Rev 0. Page D-61 of 192 ATTACHMENT 9.7 AREA WALK-BY CHECKLIST Sheet 6 of 8 IP3 Status: YEL ND UD Area Walk-By Checklist (AWC) AWC-013 Location:

Bldg, AFB Floor El. 32-6" Room, Area'SWEL Components:

SWELl-048, 035 Photographs Note: Pipe insulation interference with heater. Note: Pipe insulation with heater.EN-DC-168 REV 0 Engineering Report No IP-RPT-12-00039, Rev 0. Page D-62 of 192 ATTACHMENT 9.7 AREA WALK-BY CHECKLIST Sheet 7 of 8 IP3 Status: ND UD Area Walk-By Checklist (AWC) AWC-013 Location:

Bldg.AFB Floor El. 32-6" Room, Area 1 SWEL Components:

SWELI-048, 035 Photographs Note: Pipe insulation interference with structural Note: Air line at Door 218 steel.EN-DC-168 REV 0 Engineering Report No IP-RPT-12-00039.

Rev 0. Page D-63 of 192 ATTACHMENT 9.7 AREA WALK-BY CHECKLIST Sheet 8 of 8 IP3 Status: ND ULI Area Walk-By Checklist (AWC) AWC-013 Location:

Bldg AFB Floor El. 32'-6" Room, Area_SWEL Components:

SWELl-048, 035 Photograph EN-DC-168 REV 0 Engineering Report No. IP-RPT-12-00039, Rev. 0, Page D-64 of 192 ATTACHMENT 9.7 AREA WALK-BY CHECKLIST Sheet I of 5 1P3 Status: YEl N-- UFD Area Walk-By Checklist (AWC) AWC-014 Location:

Bldg. AFB Floor El. 43'-0" Room, Area 1 SWEL Components:

SWELl -034, 091 Instructions for Completing Checklist This checklist may be used to document the results of the Area Walk-By near one or more SWEL items. The space below each of the following questions may be used to record the results of judgments and findings.Additional space is provided at the end of this checklist for documenting other comments.1. Does anchorage of equipment in the area appear to be free of potentially adverse seismic conditions (if visible without necessarily opening cabinets)?

Yes, anchorage of equipment in the area appears to be free of potentially adverse seismic conditions.

YE N[D UD N/A[-]2. Does anchorage of equipment in the area appear to be free of significant degraded conditions?

Yes, anchorage of equipment in the area appears to be free of significant degraded conditions.

YE NEI UD- N/A--3. Based on a visual inspection from the floor, do the cable/conduit raceways and HVAC ducting appear to be free of potentially adverse seismic conditions (e.g., condition of supports is adequate and fill conditions of cable trays appear to be inside acceptable limits)?YDI NE UD- N/ADl The horizontal Unistrut support next to column H8119.5 missing a U-bolt connection to the vertical run of conduit. This condition is addressed by CR-IP3-2012-03547.

The conduit span is estimated to be 16 feet between the floor and the upper support.LB-09 evaluates this condition.

'If the room in which the SWEL item is located is very large (e.g., Turbine Hall), the area selected should be described.

This selected area should be based on judgment, e.g., on the order of about 35 feet frlom the SWEL item.EN-DC-1 68 REV 0 Engineering Report No. IP-RPT-12-00039, Rev. 0, Page D-65 of 192 ATTACHMENT 9.7 AREA WALK-BY CHECKLIST Sheet 2 of 5 IP3 Status: Yr NEI uD-]Area Walk-By Checklist (AWC) AWC-014 Location:

Bldg. AFB Floor El. 43'-0" Room, Area'SWEL Components:

SWELl -034, 091 4. Does it appear that the area is free of potentially adverse seismic YDI NE uLD N/ADl spatial interactions with other equipment in the area (e.g., ceiling tiles and lighting)?

All fluorescent light bulbs in the area need to be secured to the light fixture. This is addressed by CR-IP3-2012-03462.

5. Does it appear that the area is free of potentially adverse seismic interactions that could cause flooding or spray in the area?Yes, the area is free of potentially adverse seismic interactions that could cause flooding or spray in the area.6. Does it appear that the area is free of potentially adverse seismic interactions that could cause a fire in the area?Yes, the area is free of potentially adverse seismic interactions that could cause a fire in the area.Y[- NDI UED N/A-I YE NDI U[: N/ADI 7. Does it appear that the area is free of potentially adverse seismic interactions associated with housekeeping practices, storage of portable equipment, and temporary installations (e.g., scaffolding, lead shielding)?

Caps from nitrogen tanks are on the floor adjacent to and unsecured.

See photo. By engineering judgement, this is not considered an critical seismic issue since seismic induced displacement will not result in the caps impacting critical components.

CR-IP3-2012-03457 was issued to remedy this situation.

YEE NDI UD- N/ADl EN-DC-168 REV 0 Engineering Report No. IP-RPT-12-00039, Rev. 0, Page D-66 of 192 ATTACHMENT 9.7 AREA WALK-BY CHECKLIST ATTACHMENT 9.7 Sheet 3 of 5 1P3 Status: YU-- NOI UI-]Area Walk-By Checklist (AWC) AWC-014 Location:

Bldg. AFB Floor El. 43 Room, Area 1 SWEL Components:

SWELl-034, 091 8. Have you looked for and found no other seismic conditions that could YO NEI U-adversely affect the safety functions of the equipment in the area?Yes, we have looked for and found no other seismic conditions that could adversely affect the safety functions of the equipment in the area.Comments (Additional pages may be added as necessary)

(.Evaluated by: Paul Huebsch K)7~1J Date: 10/16/12 10/16/12 Stephen Yuan EN-DC-168 REV 0 Engineering Report No IP-RPT-12-00039, Rev 0, Page D-67 of 192 ATTACHMENT 9.7 AREA WALK-BY CHECKLIST Sheet 4 of 5 Area Walk-By Checklist (AWC) AWC-014 IP3 Status. YZ ND ULi1 Location:

Bldg. AFB Floor El. 43'-0" Room, Area'SWEL Components:

SWELl -034, 091 1 Note: The connection of the conduit riser next to column H8/19.5 is missing the U-bolt attachment to the Unistrut.Note: View of the unsupported length of conduit shown in previous picture.EN-DC-168 REV 0 Engineering Report No IP-RPT-12-00039 Rev 0. Page D-68 of 192 ATTACHMENT 9.7 AREA WALK-BY CHECKLIST Sheet 5 of 5 IP3 Status: YW ND UF Area Walk-By Checklist (AWC) AWC-014 Location:

Bldg. AFB Floor El. 43' Room, Area'SWEL Components:

SWELl -034, 091 Photographs Note: EN-DC-1 68 REV 0 Engineering Report No. IP-RPT-12-00039, Rev. 0, Page D-69 of 192 ATTACHMENT 9.7 AREA WALK-BY CHECKLIST Sheet I of 5 IP3 Status: Yt- ND UDI Area Walk-By Checklist (AWC) AWC-015 Location:

Bldg. CB Floor El. 53'-0' Room, Area 1 CONTROL ROOM SWEL Components:

SWELl -061, 062 Instructions for Completing Checklist This checklist may be used to document the results of the Area Walk-By near one or more SWEL items. The space below each of the following questions may be used to record the results of judgments and findings.Additional space is provided at the end of this checklist for documenting other comments.1. Does anchorage of equipment in the area appear to be free of potentially adverse seismic conditions (if visible without necessarily opening cabinets)?

Yes, anchorage of equipment was observed to be acceptable.

2. Does anchorage of equipment in the area appear to be free of significant degraded conditions?

Yes, anchorage of equipment was observed to be free of degraded condition.

3. Based on a visual inspection from the floor, do the cable/conduit raceways and HVAC ducting appear to be free of potentially adverse seismic conditions (e.g., condition of supports is adequate and fill conditions of cable trays appear to be inside acceptable limits)?Yes, all cables and conduits are well supported and free of adverse seismic conditions.
4. Does it appear that the area is free of potentially adverse seismic spatial interactions with other equipment in the area (e.g., ceiling tiles and lighting)?

YE NO UD1 N/A--Y[J NE] U[1 N/AD YE ND UD- N/ADI Y[ NO UD- N/AD Ceiling tiles are tied together and observed to be well secured.Therefore, the area is free of potentially adverse seismic spatial interactions with other equipment in the area.If the roomn in which the SWEL item is located is very large (e.g., Turbine Hall), the area selected should be described.

This selected area should be based on judgment, e.g., on the order of about 35 feet from the SWEL item.EN-DC-168 REV 0 Engineering Report No. IP-RPT-12-00039, Rev. 0, Page D-70 of 192 ATTACHMENT 9.7 AREA WALK-BY CHECKLIST Sheet 2 of 5 IP3 Status: Y[- ND- UD-Area Walk-By Checklist (AWC) AWC-015 Location:

Bldg. CB Floor El. 53'-0" Room, Area' CONTROL ROOM SWEL Components:

SWELl-061, 062 5. Does it appear that the area is free of potentially adverse seismic Y- NEI UE- N/A[-]interactions that could cause flooding or spray in the area?Yes, it appears that the area is free of potentially adverse seismic interactions that could cause flooding or spray in the area.6. Does it appear that the area is free of potentially adverse seismic interactions that could cause a fire in the area?Yes, it appears that the area is free of potentially adverse seismic interactions that could cause a fire in the area.7. Does it appear that the area is free of potentially adverse seismic interactions associated with housekeeping practices, storage of portable equipment, and temporary installations (e.g., scaffolding, lead shielding)?

During a seismic event, the following observations have potential to act as a missile and strike nearby sensitive equipment: (see attached photos)" Rack adjacent to Instrument Bus 31 has an unrestrained laptop and printer (also documented in IP3 SWEL 1-06 1)." Boxes against the west wall on the floor." A box resting on top of a cabinet at the northwest comer of the room." Three unrestrained binders on top of Hydrogen Recombiner No.31 Control Panel.* Unrestrained phones, printers and monitors at the work stations." Unsecured speaker on top of 34 Control Room Supplemental Cooler along the south wall.YO NED UED N/AD1 YDI NE ULIE N/AD-All the above are documented in CR-IP3-2012-03398.

8. Have you looked for and found no other seismic conditions that could Y[J NDI UD-adversely affect the safety functions of the equipment in the area?Observed a cart with 4 wheels by panel C-10. The cart is well secured to the floor with a large C-clamp. This is judged to be acceptable and it is not a seismic condition that could adversely affect the safety functions of equipment in the area.EN-DC-168 REV 0 Engineering Report No. IP-RPT-12-00039, Rev. 0, Page D-71 of 192 ATTACHMENT 9.7 Sheet 3 of 5 Area Walk-By Checklist (AWC) AWC-015 Location:

Bldg. CB Floor El. 53'-0" Room, SWEL Components:

SWELl-061.

062 Comments (Additional pages may be added as necessary)

Area1 CONTROL ROOM AREA WALK-BY CHECKLIST IP3 Status: YE- NEI U--Area' CONTROL ROOM Evaluated by: Maggie Farah Date: 10/16/2012

______________6_______

10/16/2012 KaiLo EN-DC-168 REV 0 Engineering Report No IP-RPT-12-00039.

Rev 0, Page D-72 of 192 ATTACHMENT 9.7 AREA WALK-BY CHECKLIST Sheet 4 of 5 IP3 Status: Y[E Nn Ui Area Walk-By Checklist (AWC) AWC-015 Location:

Bldg. CB Floor El. 53'-0" Room, Area' CONTROL ROOM SWEL Components:

SWELl -061, 062 Photographs Note: Rack adjacent to Instrument Bus 31 has an Note: Boxes against the west wall on the floor unrestrained laptop and printer and a box resting on top of a cabinet at the northwest comer of the room Note: unrestrained binders on top of Hydrogen Recombiner No. 31 Control Panel I'IULt:. LJIIfUt~i1dII1b'U puIffU1U.s.

P1 MIf Z5~. dflU M01UIIIIUI5 at work stations EN-DC-168 REV 0 Engineering Report No IP-RPT-12-00039, Rev 0, Page D-73 of 192 ATTACHMENT 9.7 AREA WALK-BY CHECKLIST Sheet 5 of 5 IP3 Status: NjI UEi Area Walk-By Checklist (AWC) AWC-015 Location:

Bldg. CB Floor El. 53'-0" Room, Area 1 CONTROL ROOM SWEL Components:

SWELI-061, 062 Note: Unrestrained speaker on top of 34 Control Note: Unrestrained phones, printers and monitors Room Supplemental Cooler along the south wall at work stations Note: well restrained cart by C-10.Note: no photo attached.EN-DC-168 REV 0 Engineering Report No. IP-RPT-12-00039, Rev. 0, Page D-74 of 192 ATTACHMENT 9.7 AREA WALK-BY CHECKLIST Sheet I of 4 1P3 Status: YEZ ND -IM Area Walk-By Checklist (AWC) AWC-016 Location:

Bldg. AFB Floor El. 61'-0" Room, Area 1 SWEL Components:

SWELl -004 Instructions for Completing Checklist This checklist may be used to document the results of the Area Walk-By near one or more SWEL items. The space below each of the following questions may be used to record the results of judgments and findings.Additional space is provided at the end of this checklist for documenting other comments.1. Does anchorage of equipment in the area appear to be free of potentially adverse seismic conditions (if visible without necessarily opening cabinets)?

Yes, anchorage of equipment in the area appears to be free of potentially adverse seismic conditions.

YZ NDI UD- N/AD-2. Does anchorage of equipment in the area appear to be free of significant degraded conditions?

Yes, anchorage of equipment in the area appears to be free of significant degraded conditions.

YE] NDI UDI N/AD 3. Based on a visual inspection from the floor, do the cable/conduit raceways and HVAC ducting appear to be free of potentially adverse seismic conditions (e.g., condition of supports is adequate and fill conditions of cable trays appear to be inside acceptable limits)?YE ND_ UD] N/AD-q Yes, the cable/conduit raceways and HVAC ducting appear to be free of potentially adverse seismic conditions.

If the room in which the SWEL item is located is ver'N, large (e.g., Turbine Hall), the area selected should be described.

11is selected area should be based on judgment, e.g., on the order of about 35 feet from the SWEL item.EN-DC-168 REV 0 Engineering Report No. IP-RPT-12-00039, Rev. 0, Page D-75 of 192 ATTACHMENT 9.7 AREA WALK-BY CHECKLIST Sheet 2 of 4 IP3 Status: Y[1 ND UDF Area Walk-By Checklist (AWC) AWC-016 Location:

Bldg. AFB Floor El. 61'-0" Room, Area'SWEL Components:

SWELl -004 4. Does it appear that the area is free of potentially adverse seismic YD] N L UIE N/AD-1 spatial interactions with other equipment in the area (e.g., ceiling tiles and lighting)?

Some sections of grating are not attached to the steel beam below.CR-IP3-2012-03473 was issued to remedy this situation.

5. Does it appear that the area is free of potentially adverse seismic interactions that could cause flooding or spray in the area?Yes, the area is free of potentially adverse seismic interactions that could cause flooding or spray in the area.6. Does it appear that the area is free of potentially adverse seismic interactions that could cause a fire in the area?Yes, the area is free of potentially adverse seismic interactions that could cause a fire in the area.YZ NDI U[D] N/A--Y[1 NDI UED N/AD-7. Does it appear that the area is free of potentially adverse seismic interactions associated with housekeeping practices, storage of portable equipment, and temporary installations (e.g., scaffolding, lead shielding)?

All fluorescent light bulbs in the area need to be secured to the light fixture. This is addressed by CR-IP3-2012-03462 YD- NE UD- N/AD 8. Have you looked for and found no other seismic conditions that could Y[I NDI uD-adversely affect the safety functions of the equipment in the area?No other seismic conditions that could adversely affect the safety functions of the equipment in the area.EN-DC-168 REV 0 Engineering Report No. IP-RPT-12-00039, Rev. 0, Page D-76 of 192 ATTACHMENT 9.7 Sheet 3 of 4 Area Walk-By Checklist (AWC) AWC-016 Location:

Bldg. AFB Floor El. 61'-0" Room, Area'SWEL Components:

SWELl-004 AREA WALK-By CHECKLIST IP3 Status: YES NF U-Comments (Additional pages may be added as necessary)

Few florescent bulbs near south end of the platform are out and need to be replaced.

This is addressed by CR-IP3-2012-03462 The paint of west wall is peeling off Needs new paint.(-9 Date: 10/17/12 Evaluated by: Paul Huebsch C, Stenhen Yuan " 10/17/12 Stephen Yuan :'EN-DC-168 REV 0 Engineering Report No IP-RPT-12-00039 Rev. 0. Page D-77 of 192 ATTACHMENT 9.7 AREA WALK-BY CHECKLIST Sheet 4 of 4 IP3 Note: Some sections of grating are not attached to the steel beam below.Note: EN-DC-168 REV 0 Engineering Report No. IP-RPT-12-00039, Rev. 0, Page D-78 of 192 ATTACHMENT 9.7 AREA WALK-BY CHECKLIST Sheet I of 5 IP3 Status: YE NDI Ur-I Area Walk-By Checklist (AWC) AWC-017 Location:

Bldg. AFB Floor El. 73'-8" Room, Area 1 SWEL Components:

SWELl -003, 041, 042, 043, 044 Instructions for Completing Checklist This checklist may be used to document the results of the Area Walk-By near one or more SWEL items. The space below each of the following questions may be used to record the results of judgments and findings.Additional space is provided at the end of this checklist for documenting other comments.1. Does anchorage of equipment in the area appear to be free of potentially adverse seismic conditions (if visible without necessarily opening cabinets)?

Yes, anchorage of equipment in the area appears to be free of potentially adverse seismic conditions.

YZ NEI UD-- N/A--2. Does anchorage of equipment in the area appear to be free of significant degraded conditions?

Anchorage of equipment in the area appears to be free of significant degraded conditions.

Y[- ND UDI N/A[D]3. Based on a visual inspection from the floor, do the cable/conduit raceways and HVAC ducting appear to be free of potentially adverse seismic conditions (e.g., condition of supports is adequate and fill conditions of cable trays appear to be inside acceptable limits)?YE NDI UD N/AD The cable/conduit raceways and HVAC ducting appear to be free of potentially adverse seismic conditions.

If the room in which the SWEL item is located is very large (e.g., Turbine Hall), the area selected should be described.

This selected area should be based on judgment, e.g., on the order of about 35 feet from the SWEL item.EN-DC-168 REV 0 Engineering Report No. IP-RPT-12-00039, Rev. 0, Page D-79 of 192 ATTACHMENT 9.7 AREA WALK-BY CHECKLIST Sheet 2 of 5 IP3 Status: YE NDI UD Area Walk-By Checklist (AWC) AWC-017 Location:

Bldg. AFB Floor El. 73'-8" Room, Area'SWEL Components:

SWELl -003, 041, 042, 043, 044 4. Does it appear that the area is free of potentially adverse seismic YDI UI N/AD-spatial interactions with other equipment in the area (e.g., ceiling tiles and lighting)?

Floor grating is not attached to the steel support beams. Most grating is restrained laterally by the pipe supports and the wall on the opposite side. However some panels are only restrained by the wall and could displace laterally under seismic action. Adjacent panels cannot restrain the loose panels because the toe board is not continuous but is attached to each individual panel. They could then impact the main steam lines. CR-IP3-2012-03473 was issued to remedy this situation.

5. Does it appear that the area is free of potentially adverse seismic interactions that could cause flooding or spray in the area?The area is free of potentially adverse seismic interactions that could cause flooding or spray in the area.6. Does it appear that the area is free of potentially adverse seismic interactions that could cause a fire in the area?The area is free of potentially adverse seismic interactions that could cause a fire in the area.Y[ ND:] UD N/AD YEI NDI UDI N/AD 7. Does it appear that the area is free of potentially adverse seismic interactions associated with housekeeping practices, storage of portable equipment, and temporary installations (e.g., scaffolding, lead shielding)?

The area is free of potentially adverse seismic interactions associated with housekeeping practices, storage of portable equipment, and temporary installations YN ND-] UD- N/AD1 EN-DC-168 REV 0 Engineering Report No. IP-RPT-12-00039, Rev. 0, Page D-80 of 192 ATTACHMENT 9.7 Sheet 3 of 5 Area Walk-By Checklist (AWC) AWC-017 Location:

Bldg. AFB Floor El. 73'-8" Room, Area'SWEL Components:

SWELl -003, 041, 042, 043, 044 8. Have you looked for and found no other seismic conditions that could adversely affect the safety functions of the equipment in the area?All fluorescent light bulbs in the area need to be secured to the fixture.This is addressed by CR-IP3-2012-03462.

A few fluorescent bulbs near south end of the platform are out and need to be replaced.One of the fluorescent fixtures is touching the steel hanger. This was addressed in SWEL 1-003.AREA WALK-BY CHECKLIST IP3 Status: YE ND-- U-YI- NO UD-Comments (Additional pages may be added as necessary)

The insulation cover on an overhead pipe is peeling off See photo.Evaluated by: Paul Huebsch____Date:

10/17/12/__ -Date: 10/17/12 Stephen Yuan EN-DC-168 REV 0 Engineering Report No IP-RPT-12-00039, Rev 0, Page D-81 of 192 ATTACHMENT 9.7 AREA WALK-BY CHECKLIST Sheet 4 of 5 IP3 Note: some sections ot grating are not attached to the steel beam below.AULU. ooumie ouios near souw eno or the platform are out and need to be replaced.EN-DC-168 REV 0 Engineering Report No IP-RPT-12-00039 Rev 0 Page D-82 of 192 ATTACHMENT 9.7 AREA WALK-By CHECKLIST Sheet 5 of 5 Photographs IP3 Iimue; urne or ine norescem Tixtures is oucning ine rdoxe: i ne insutation cover or me ovemeaa pipe is steel hanger peeling off EN-DC-168 REV 0 Engineering Report No. IP-RPT-12-00039, Rev. 0, Page D-83 of 192 ATTACHMENT 9.7 AREA WALK-BY CHECKLIST Sheet I of 5 IP3 Status: Y-Z N-- Ui Area Walk-By Checklist (AWC) AWC-018 Location:

Bldg. CST Floor El. 69'-0" Room, Area' Yard SWEL Components:

SWELl -095 Instructions for Completing Checklist This checklist may be used to document the results of the Area Walk-By near one or more SWEL items. The space below each of the following questions may be used to record the results of judgments and findings.Additional space is provided at the end of this checklist for documenting other comments.1. Does anchorage of equipment in the area appear to be free of potentially adverse seismic conditions (if visible without necessarily opening cabinets)?

The base plates of support columns on adjacent platforms have four holes in the base plates but only two anchors installed on diagonal holes. This condition is judged to be acceptable based on the low height of the platform and the minimum weight of the framing and fiberglass grating.2. Does anchorage of equipment in the area appear to be free of significant degraded conditions?

Several screws are missing from the face closures of the electric panels. See attached photo.-Since weight of the closure panel is less than 40#, and peak acceleration from ground response spectra is 0.64, 14 out of 22 screws are more than adequate to hold the panel in place.All the conduit and pipes show sign of corrosion.

3. Based on a visual inspection from the floor, do the cable/conduit raceways and HVAC ducting appear to be free of potentially adverse seismic conditions (e.g., condition of supports is adequate and fill conditions of cable trays appear to be inside acceptable limits)?YF>< NEI U-- N/Al Y[J NI UL- N/A-YE ND UD- N/AD The tank is free of potentially adverse seismic conditions from overhead conduits and HVAC ducting.If the room in which the SWEL item is located is very., large (e.g., Turbine Hall), the area selected should be described.

This selected area should be based on judgment, e.g., on the order of about 35 feet fr'om the SWEL item.EN-DC-168 REV 0 Engineering Report No IP-RPT-12-00039, Rev. 0, Page D-84 of 192 ATTACHMENT 9.7 AREA WALK-BY CHECKLIST Sheet 2 of 5 1P3 Status: Y-- NEI UD-Area Walk-By Checklist (AWC) AWC-018 Location:

Bldg. CST Floor El. 69'-0" Room, Area 1 Yard SWEL Components:

SWELl -095 4. Does it appear that the area is free of potentially adverse seismic YLI NE UD] N/AD-spatial interactions with other equipment in the area (e.g., ceiling tiles and lighting)?

The lighting poles near the tank need to be verified for seismic adequacy.-LB-1I evaluates this condition.

5. Does it appear that the area is free of potentially adverse seismic interactions that could cause flooding or spray in the area?The area is free of potentially adverse seismic interactions that could cause flooding or spray in the area.6. Does it appear that the area is free of potentially adverse seismic interactions that could cause a fire in the area?The area is free of potentially adverse seismic interactions that could cause a fire in the area.YE ND-] UD N/A--YO NDI UD- N/AD 7. Does it appear that the area is free of potentially adverse seismic interactions associated with housekeeping practices, storage of portable equipment, and temporary installations (e.g., scaffolding, lead shielding)?

The area is free of potentially adverse seismic interactions associated with housekeeping practices, storage of portable equipment, and temporary installations.

Y-- NDl U[l N/AD-EN-DC-168 REV 0 Engineering Report No. IP-RPT-12-00039, Rev. 0, Page D-85 of 192 ATTACHMENT 9.7 Sheet 3 of 5 Area Walk-By Checklist (AWC) AWC-018 Location:

Bldg. CST Floor El. 69*-0" Room, Area 1 Yard SWEL Components:

SWELl -095 8. Have you looked for and found no other seismic conditions that could adversely affect the safety functions of the equipment in the area?No other seismic conditions that could adversely affect the safety functions of the equipment in the area were identified.

AREA WALK-By CHECKLIST IP3 Status: YM NLE U--Y[Z NEI UD--Comments (Additional pages may be added as necessary)

<j~i2, IvL 7 Evaluated by: Paul Huebsch/Date: 10/17/12 Date: 10/17/12 Stephen Yuan EN-DC-168 REV 0 Engineering Report No IP-RPT-12-00039.

Rev 0. Page D-86 of 192 ATTACHMENT 9.7 Sheet 4 of 5 Area Walk-By Checklist (AWC) AWC-018 AREA WALK-BY CHECKLIST IP3 Status: Y[1 ND UE1 Location:

Bldg. CST Floor El. 69'-0" Room, Area 1 Yard SWIEL1-095 SWEL Components:

SWEL1 -095 Noie: zieveral screws are missing roi panels EN-DC-168 REV 0 Engineenng Report No IP-RPT-12-00039.

Rev 0 Page D-87 of 192 ATTACHMENT 9.7 Sheet 5 of 5 Area Walk-By Checklist (AWC) AWC-018 Location-Bldg. CST Floor El. 69'-0' F AREA WALK-BY CHECKLIST IP3 Status: YE NER UE Room, Area' Yard SWEL Components:

SWEL1 -095 Photographs Note: The lighting poles near the tank need to be verified for seismic adequacy.Note: All the conduit and pipes show sign of various stages of corrosion.

EN-DC-168 REV 0 Engineering Report No. IP-RPT-12-00039, Rev. 0, Page D-88 of 192 ATTACHMENT 9.7 AREA WALK-BY CHECKLIST Sheet I of 4 IP3 Status: YI- ND- UFi1 Area Walk-By Checklist (AWC) AWC-019 Location:

Bldg. DG Floor El. 15'-0" Room, Area' 31 DIESEL GENERATOR ROOM SWEL Components:

SWELl -076, 067, 088, 096 Instructions for Completing Checklist This checklist may be used to document the results of the Area Walk-By near one or more SWEL items. The space below each of the following questions may be used to record the results of judgments and findings.Additional space is provided at the end of this checklist for documenting other comments.1. Does anchorage of equipment in the area appear to be free of potentially adverse seismic conditions (if visible without necessarily opening cabinets)?

Observed a wide flange across the room (spanning east-west) supporting air intake piping with gaps between the base plate and the wall. The gaps are observed to be approximately between 1/8" to 1/4" (see attached photo). Per procedure O-RES-400-GEN, the allowable gap shall not be greater than 3/32". This 1/8" to Y4" gap may result in bending of the anchor bolts. This is addressed in CR-IP3-2012-03361.

LB-05 evaluates this condition.

2. Does anchorage of equipment in the area appear to be free of significant degraded conditions?

Yes, anchorage of equipment in the area appears to be free of significant degraded conditions.

3. Based on a visual inspection from the floor, do the cable/conduit raceways and HVAC ducting appear to be free of potentially adverse seismic conditions (e.g., condition of supports is adequate and fill conditions of cable trays appear to be inside acceptable limits)?YDI NE UDI N/A[D Y[ NEI U-I N/AD Y-I NE UD- N/A-I Observed a not tightly secured metal wire trough located on the east wall (above the speaker).

The wire trough is attached two Unistruts channels with one Unistrut bolt on each channel at the top. There is an approximately Y4" to 1" gap between the wire trough and the Unistrut (see photos). The wire trough seems to be light in weigh; however, during a seismic event the trough may dislodge and strike nearby equipment.

The wire trough should be properly secured to prevent any adverse seismic conditions.

This is addressed in CR-IP3-2012-03363.

I If the room in which the SWEL item is located is very large (e.g., Turbine Hall), the area selected should be described.

This selected area should be based on judgment, e.g., on the order of about 35 feet from the SWEL item.EN-DC-168 REV 0 Engineering Report No. IP-RPT-12-00039, Rev. 0, Page D-89 of 192 ATTACHMENT 9.7 AREA WALK-BY CHECKLIST Sheet 2 of 4 IP3 Status: YX NF UF-I Area Walk-By Checklist (AWC) AWC-019 Location:

Bldg. DG Floor El. 15'-0' Room, Area' 31 DIESEL GENERATOR ROOM SWEL Components:

SWELl -076, 067, 088, 096 4. Does it appear that the area is free of potentially adverse seismic YE] NEI UD N/AD1 spatial interactions with other equipment in the area (e.g., ceiling tiles and lighting)?

Yes, it appears that the area is free of potentially adverse seismic spatial interactions with other equipment in the area.5. Does it appear that the area is free of potentially adverse seismic interactions that could cause flooding or spray in the area?Yes, it appears that the area is free of potentially adverse seismic interactions that could cause flooding or spray in the area.Y[ NDI UD- N/AED 6. Does it appear that the area is free of potentially adverse seismic interactions that could cause a fire in the area?Yes, it appears that the area is free of potentially adverse seismic interactions that could cause a fire in the area.YX1 NDI ULD N/AD 7. Does it appear that the area is free of potentially adverse seismic interactions associated with housekeeping practices, storage of portable equipment, and temporary installations (e.g., scaffolding, lead shielding)?

Yes, it appears that the area is free of potentially adverse seismic interactions associated with housekeeping practices, storage .of portable equipment, and temporary installations Y[N NDI uID N/AD-EN-DC-1 68 REV 0 Engineering Report No. IP-RPT-12-00039, Rev. 0, Page D-90 of 192 ATTACHMENT 9.7 AREA WALK-BY CHECKLIST Sheet 3 of 4 IP3 Status: YEZ NEI UFiI Area Walk-By Checklist (AWC) AWC-019 Location:

Bldg. DG Floor El. 15'-0" Room, Area 1 31 DIESEL GENERATOR ROOM SWEL Components:

SWELl -076, 067, 088, 096 8. Have you looked for and found no other seismic conditions that could YE Nr- UFI--adversely affect the safety functions of the equipment in the area?Yes, we have looked for and found no other seismic conditions that could adversely affect the safety functions of the equipment in the area.Comments (Additional pages may be added as necessary)

References:

IP3 SWEL1-076, 1-067, 1-088, 1-096 wlwýEvaluated by: Maggie Farah Date: 10/19/12 Kai Lo /C6 10/19/12 EN-DC-168 REV 0 Engineering Report No IP-RPT-12-00039 Rev 0. Page D-91 of 192 ATTACHMENT 9.7 AREA WALK-BY CHECKLIST Sheet 4 of 4 IP3 Status; ND Util Area Walk-By Checklist (AWC) AWC-019 Location:

Bldg. DG Floor El. 15'-0" Room, Area' 31 DIESEL GENERATOR ROOM SWEL Components:

SWELl -076, 067, 088, 096 Photographs Note: Gap between the base plate and wall. Note: Gaps between wire trough and Unistrut looking south.Note: Ga looking no ap between wire trough and Unistrut rth.Note: (5ap between wire trough and Unistrut looking north.EN-DC-168 REV 0 Engineering Report No. IP-RPT-12-00039, Rev. 0, Page D-92 of 192 ATTACHMENT 9.7 AREA WALK-BY CHECKLIST Sheet I of 4 IP3 Status: YE NDJ UD]Area Walk-By Checklist (AWC) AWC-020 Location:

Bldg. DG Floor El. 15-0' Room, Area 1 32 DIESEL GENERATOR ROOM SWEL Components:

SWELl-077.

058, 100 Instructions for Completing Checklist This checklist may be used to document the results of the Area Walk-By near one or more SWEL items. The space below each of the following questions may be used to record the results of judgments and findings.Additional space is provided at the end of this checklist for documenting other comments.1. Does anchorage of equipment in the area appear to be free of potentially adverse seismic conditions (if visible without necessarily opening cabinets)?

Y- ND uD- N/A-1 Yes, anchorage of equipment in the area appears to be free of potentially adverse seismic conditions.

2. Does anchorage of equipment in the area appear to be free of significant degraded conditions?

Yes, anchorage of equipment in the area appears to be free of significant degraded conditions.

YE ND uD N/AD 3. Based on a visual inspection from the floor, do the cable/conduit raceways and HVAC ducting appear to be free of potentially adverse seismic conditions (e.g., condition of supports is adequate and fill conditions of cable trays appear to be inside acceptable limits)?YZ ND uD1 N/AD-Yes, based on a visual inspection from the floor, the cable/conduit raceways and HVAC ducting appears to be free of potentially adverse seismic conditions.

If the room in which the SWEL item is located is very large (e.g., Turbine Hall), the area selected should be described.

T1his selected area should be based oil judgment, e.g., oil the order of about 35 feet from the SWEL item.EN-DC-168 REV 0 Engineering Report No. IP-RPT-12-00039, Rev. 0, Page D-93 of 192 ATTACHMENT 9.7 AREA WALK-BY CHECKLIST Sheet 2 of 4 IP3 Status: YN N-- UM Area Walk-By Checklist (AWC) AWC-020 Location:

Bldg. DG Floor El. 15'-0" Room, Area 1 32 DIESEL GENERATOR ROOM SWEL Components:

SWELl-077, 058, 100 4. Does it appear that the area is free of potentially adverse seismic Y[X Nil UD:] N/A[-]spatial interactions with other equipment in the area (e.g., ceiling tiles and lighting)?

Yes. it appears that the area is free of potentially adverse seismic spatial interactions with other equipment in the area.5. Does it appear that the area is free of potentially adverse seismic interactions that could cause flooding or spray in the area?Yes, it appears that the area is free of potentially adverse seismic interactions that could cause flooding or spray in the area.Y-- NDI uD1 N/AD 6. Does it appear that the area is free of potentially adverse seismic interactions that could cause a fire in the area?Yes, it appears that the area is free of potentially adverse seismic interactions that could cause a fire in the area.YE NDI uD- N/AD I 7. Does it appear that the area is free of potentially adverse seismic interactions associated with housekeeping practices, storage of portable equipment, and temporary installations (e.g., scaffolding, lead shielding)?

Observed scaffold #4355 erected on 7/25/12. The scaffolding seems well supported and was judged acceptable.

Therefore, the area is free of potentially adverse seismic interactions associated with housekeeping practices, storage of portable equipment, and temporary installations.

YE NDI U-D N/AD1 EN-DC-168 REV 0 Engineering Report No. IP-RPT-12-00039, Rev. 0, Page D-94 of 192 ATTACHMENT 9.7 AREA WALK-BY CHECKLIST Sheet 3 of 4 IP3 Status: YE[ NF- UMi Area Walk-By Checklist (AWC) AWC-020 Location:

Bldg. DG Floor El. 15'-0" Room, Area' 32 DIESEL GENERATOR ROOM SWEL Components:

SWELl -077, 058, 100 8. Have you looked for and found no other seismic conditions that could Y[N Nl ULIM adversely affect the safety functions of the equipment in the area?Yes, we have looked for and found no other seismic conditions that could adversely affect the safety functions of the equipment in the area.Comments (Additional pages may be added as necessary)

Observed three ceiling light bulbs that need to be replaced.

This is not a seismic concem. Replacement of bulbs is addressed in CR-IP3-2012-03363.

References:

IP3 SWELl-077, 1-058, 1-100 Jý 'Evaluated by: Maggie Farah Date: 10/19/2012 Date: 10/19/2012 Stephen Yuan EN-DC-1 68 REV 0 Engineering Report No. IP-RPT-12-00039, Rev. 0, Page D-95 of 192 ATTACHMENT 9.7 AREA WALK-BY CHECKLIST Sheet 4 of 4 IP3 Status: Y- NFI- U[-I Area Walk-By Checklist (AWC) AWC-020 Location:

Bldg. DG Floor El. 15'-0' Room, Area' 32 DIESEL GENERATOR ROOM SWEL Components:

SWELl -077, 058. 100 Photographs Note: no photos attached Note: EN-DC-168 REV 0 Engineering Report No. IP-RPT-12-00039, Rev. 0, Page D-96 of 192 ATTACHMENT 9.7 AREA WALK-BY CHECKLIST Sheet I of 4 IP3 Status: YO NEI UI Area Walk-By Checklist (AWC) AWC-021 Location:

Bldg. DG Floor El. 15'-0" Room, Area 1 33 DIESEL GENERATOR ROOM SWEL Components:

SWELl -078 Instructions for Completing Checklist This checklist may be used to document the results of the Area Walk-By near one or more SWEL items. The space below each of the following questions may be used to record the results of judgments and findings.Additional space is provided at the end of this checklist for documenting other comments.1. Does anchorage of equipment in the area appear to be free of potentially adverse seismic conditions (if visible without necessarily opening cabinets)?

Observed a wide flange across the room (spanning east-west) supporting B574 duct with a gap between the base plate and the east wall. The gap is observed to be approximately between 1/8" to Y 4" (see attached photo). This gap may result in bending of the anchor bolts.This is addressed in CR-IP3-2012-03361.

LB-05 evaluates this condition.

2. Does anchorage of equipment in the area appear to be free of significant degraded conditions?

Yes, anchorage of equipment in the area appears to be free of significant degraded conditions.

YD NO U[D- N/A-YO N[- UFD N/AD 3. Based on a visual inspection from the floor, do the cable/conduit raceways and HVAC ducting appear to be free of potentially adverse seismic conditions (e.g., condition of supports is adequate and fill conditions of cable trays appear to be inside acceptable limits)?Y[ N[: U-I N/AD Yes, based on a visual inspection from the floor, the cable/conduit raceways and HVAC ducting appears to be free of potentially adverse seismic conditions.

If the room in which the SWEL item is located is veryN large (e.g., Turbine Hall), the area selected should be described."l1nis selected area should be based on judgment, e.g., on the order of about 35 feet fr'om the SWEL item.EN-DC-168 REV 0 Engineering Report No. IP-RPT-12-00039, Rev. 0, Page D-97 of 192 ATTACHMENT 9.7 AREA WALK-BY CHECKLIST Sheet 2 of 4 IP3 Status: YZ ND- U-]Area Walk-By Checklist (AWC) AWC-021 Location:

Bldg. DG FloorEl. 15'-0" Room, Area 1 33 DIESEL GENERATOR ROOM SWEL Components:

SWELl-078 4. Does it appear that the area is free of potentially adverse seismic Y[ NDI UD- N/A[D-spatial interactions with other equipment in the area (e.g., ceiling tiles and lighting)?

Yes, it appears that the area is free of potentially adverse seismic spatial interactions with other equipment in the area.5. Does it appear that the area is free of potentially adverse seismic interactions that could cause flooding or spray in the area?Yes, it appears that the area is free of potentially adverse seismic interactions that could cause flooding or spray in the area.YZ ND UD- N/A[-]6. Does it appear that the area is free of potentially adverse seismic interactions that could cause a fire in the area?Yes, it appears that the area is free of potentially adverse seismic interactions that could cause a fire in the area.Y-- ND] UD- N/AD1 7. Does it appear that the area is free of potentially adverse seismic interactions associated with housekeeping practices, storage of portable equipment, and temporary installations (e.g., scaffolding, lead shielding)?

Yes, it appears that the area is free of potentially adverse seismic interactions associated with housekeeping practices, storage of portable equipment, and temporary installations.

YE NE uD] N/AD EN-DC-168 REV 0 Engineering Report No. IP-RPT-12-00039, Rev. 0, Page D-98 of 192 ATTACHMENT 9.7 AREA WALK-BY CHECKLIST Sheet 3 of 4 IP3 Status: YEZ N-I UDi Area Walk-By Checklist (AWC) AWC-021 Location:

Bldg. DG Floor El. 15'-0" Room, Area' 33 DIESEL GENERATOR ROOM SWEL Components:

SWELl-078 8. Have you looked for and found no other seismic conditions that could YO NEI UD--adversely affect the safety functions of the equipment in the area?Yes, we have looked for and found no other seismic conditions that could adversely affect the safety functions of the equipment in the area.Comments (Additional pages may be added as necessary)

Observed two ceiling light bulbs that need to be replaced.

The light bulb replacement is addressed in CR-IP3-2012-3363.

Reference:

IP3 SWELl-078 wtculý'_Evaluated by: Maggie Farah Date: 10/19/12_10/19/12 Stephen Yuan EN-DC-168 REV 0 Engineering Report No IP-RPT-12-00039.

Rev 0. Page D-99 of 192 ATTACHMENT 9.7 AREA WALK-BY CHECKLIST Sheet 4 of 4 IP3 Status: YE ND UI--Area Walk-By Checklist (AWC) AWC-021 Location:

Bldg. DG Floor El. 15'-0" Room, Area' 33 DIESEL GENERATOR ROOM SWEL Components:

SWELl-078 Photographs Note wide flanae across the room (spanning east- Note: west) supporting B574 duct with a gap between the base plate and the east wall EN-DC-168 REV 0 Engineering Report No. IP-RPT-12-00039, Rev. 0, Page D-100 of 192 ATTACHMENT 9.7 AREA WALK-BY CHECKLIST Sheet I of 4 IP3 Status: YE ND Ui--Area Walk-By Checklist (AWC) AWC-022 Location:

Bldg. PA Floor El. 41'-0" Room, Area 1 SWEL Components:

SWELl -025 Instructions for Completing Checklist This checklist may be used to document the results of the Area Walk-By near one or more SWEL items. The space below each of the following questions may be used to record the results of judgments and findings.Additional space is provided at the end of this checklist for documenting other comments.1. Does anchorage of equipment in the area appear to be free of potentially adverse seismic conditions (if visible without necessarily opening cabinets)?

Yes, anchorage of equipment in the area appears to be free of potentially adverse seismic conditions.

YE NEI U[-] N/A--2. Does anchorage of equipment in the area appear to be free of significant degraded conditions?

Yes, anchorage of equipment in the area appears to be free of significant degraded conditions.

YE N[-] UD- N/AD-3. Based on a visual inspection from the floor, do the cable/conduit raceways and HVAC ducting appear to be free of potentially adverse seismic conditions (e.g., condition of supports is adequate and fill conditions of cable trays appear to be inside acceptable limits)?YE NDI UDI N/AD]Yes, based on a visual inspection from the floor, the cable/conduit raceways and HVAC ducting appears to be free of potentially adverse seismic conditions.

'If the room in which the SWEL itein is located is velrY large (e.g., Turbine Hall), the area selected should be described.

This selected area should be based on judgment, e.g., on the order of about 35 feet fr'om the SWEL item.EN-DC-168 REV 0 Engineering Report No. IP-RPT-12-00039, Rev. 0, Page D-101 of 192 ATTACHMENT 9.7 AREA WALK-BY CHECKLIST Sheet 2 of 4 1P3 Status: YZ1 NR UF-Area Walk-By Checklist (AWC) AWC-022 Location:

Bldg. PA Floor El. 41'-0" Room, Area'SWEL Components:

SWELl-025 4. Does it appear that the area is free of potentially adverse seismic spatial interactions with other equipment in the area (e.g., ceiling tiles and lighting)?

Yes, it appears that the area is free of potentially adverse seismic spatial interactions with other equipment in the area.YZ NWI UW N/AF-5. Does it appear that the area is free of potentially adverse seismic interactions that could cause flooding or spray in the area?Yes, it appears that the area is free of potentially adverse seismic interactions that could cause flooding or spray in the area.Y[Z NEI uW- N/ADI 6. Does it appear that the area is free of potentially adverse seismic interactions that could cause a fire in the area?Yes, it appears that the area is free of potentially adverse seismic interactions that could cause a fire in the area.YE NEI UI- N/A--7. Does it appear that the area is free of potentially adverse seismic interactions associated with housekeeping practices, storage of portable equipment, and temporary installations (e.g., scaffolding, lead shielding)?

Observed a broken fluorescent light fixture directly above CS Pump 32.The fixture is tied in the center (with rope or zip tie) but loose at the north end. During a seismic event the fixture may fall and strike the oil reservoir or any sensitive equipment (see attached photo). This is addressed in CR-IP3-2012-03481.

YD- NZ U-- N/AD EN-DC-168 REV 0 Engineering Report No. IP-RPT-12-00039, Rev. 0, Page D-102 of 192 ATTACHMENT 9.7 AREA WALK-BY CHECKLIST Sheet 3 of 4 IP3 Status: YZ Nr U-Area Walk-By Checklist (AWC) AWC-022 Location:

Bldg. PA Floor El. 41'-0" Room, Area'SWEL Components:

SWELl -025 8. Have you looked for and found no other seismic conditions that could YE NO UDI-adversely affect the safety functions of the equipment in the area?Yes, we have looked for and found no other seismic conditions that could adversely affect the safety functions of the equipment in the area.Comments (Additional pages may be added as necessary)

EDate: 10/22/12 Evaluated by- Maq-gie Farah KaiLo /10/22/12 EN-DC-168 REV 0 Engineering Report No. IP-RPT-12-00039, Rev 0. Page D-103 of 192 ATTACHMENT 9.7 AREA WALK-BY CHECKLIST Sheet 4 of 4 IP3 Status: YE[ NFI UL Area Walk-By Checklist (AWC) AWC-022 Location:

Bldg. PA Floor El. 41'-0" Room, Area'SWEL Components:

SWELl-025 Photographs EN-DC-168 REV 0 Engineering Report No. IP-RPT-12-00039, Rev. 0, Page D-104 of 192 ATTACHMENT 9.7 AREA WALK-BY CHECKLIST Sheet I of 6 IP3 Status: YE] NEI UD--Area Walk-By Checklist (AWC) AWC-023 Location:

Bldg. PA Floor El. 41'-0 Roorn, Area 1 SWEL Components:

SWELl-024 Instructions for Completing Checklist This checklist may be used to document the results of the Area Walk-By near one or more SWEL items. The space below each of the following questions may be used to record the results of judgments and findings.Additional space is provided at the end of this checklist for documenting other comments.1. Does anchorage of equipment in the area appear to be free of potentially adverse seismic conditions (if visible without necessarily opening cabinets)?

Yes, anchorage of equipment in the area appears to be free of potentially adverse seismic conditions.

2. Does anchorage of equipment in the area appear to be free of significant degraded conditions?

Yes, anchorage of equipment in the area appears to be free of significant degraded conditions.

3. Based on a visual inspection from the floor, do the cable/conduit raceways and HVAC ducting appear to be free of potentially adverse seismic conditions (e.g., condition of supports is adequate and fill conditions of cable trays appear to be inside acceptable limits)?Yes, based on a visual inspection from the floor, the cable/conduit raceways and HVAC ducting appears to be free of potentially adverse seismic conditions.
4. Does it appear that the area is free of potentially adverse seismic spatial interactions with other equipment in the area (e.g., ceiling tiles and lighting)?

Observed Fluorescent light bulbs that are not secured or tied to the light fixture. During a seismic event, the bulbs may become loose and strike nearby sensitive equipment.

This is addressed in IP3 SWELI-024 and CR-IP3-2012-03481.

YE NEI UlI N/AD-]Y] NEI UD- N/A-YN NDI Ui- N/ADl Y-- NI ULID N/AD-IIf the room in which the SWEL item is located is venr large (e.g., Turbine Hall), the area selected should be described.

This selected area should be based on judgment, e.g.. on the order of about 35 feet from the SWEL item.EN-DC-168 REV 0 Engineering Report No. IP-RPT-12-00039, Rev. 0, Page D-105 of 192 ATTACHMENT 9.7 AREA WALK-BY CHECKLIST Sheet 2 of 6 IP3 Status: NF U-I Area Walk-By Checklist (AWC) AWC-023 Location:

Bldg. PA FloorEl. 41'-0 Room,Area 1 SWEL Components:

SWELl-024 5. Does it appear that the area is free of potentially adverse seismic interactions that could cause flooding or spray in the area?Yes, it appears that the area is free of potentially adverse seismic interactions that could cause flooding or spray in the area.6. Does it appear that the area is free of potentially adverse seismic interactions that could cause a fire in the area?Yes, it appears that the area is free of potentially adverse seismic interactions that could cause a fire in the area.7. Does it appear that the area is free of potentially adverse seismic interactions associated with housekeeping practices, storage of portable equipment, and temporary installations (e.g., scaffolding, lead shielding)?

Observed tools, cables, parts resting on top of the CCW tank (see attached photos).Observed two buckets (collecting drips) at 32 CCW pump (see attached photos).Observed a bucket (with wheels) and mop stick near the hot water heater near Sump Pump 37 (see attached photo).Observed hoses coming out of CCW tank that are laid over piping, piping supports and ducts that are not tied down. The ends of two hoses seem to travel to an upper elevation connecting to another CCW tank. Another hose is resting on top of a pipe near SWN-32.Observed a ladder near the Appendix R safe shutdown ladder that is not restrained.

The aforementioned items must be tied down/properly secured or removed to prevent any interaction with nearby equipment.

This is addressed in CR-IP3-2012-03501.

Y[Z NDI UD- N/ADI YE] NDI ULE] N/ADI YE NE Ul-I N/ADI EN-DC-168 REV 0 Engineering Report No. IP-RPT-12-00039, Rev 0, Page D-106 of 192 ATTACHMENT 9.7 AREA WALK-BY CHECKLIST Sheet 3 of 6 IP3 Status: YE NI U-Area Walk-By Checklist (AWC) AWC-023 Location:

Bldg. PA FloorEl. 41'-0 Room,Area 1 SWEL Components:

SWELl-024 8. Have you looked for and found no other seismic conditions that could Y[Z NEI UD adversely affect the safety functions of the equipment in the area?Yes, we have looked for and found no other seismic conditions that could adversely affect the safety functions of the equipment in the area.Comments (Additional pages may be added as necessary)

Reference:

IP3 SWEL 1-024 Evaluated by: Maggie Farah Date: 10/22/12 Kai Lo /C- 6 10/22/12 EN-DC-1 68 REV 0 Engineering Report No IP-RPT-12-00039 Rev 0 Page D-107 of 192 ATTACHMENT 9.7 AREA WALK-BY CHECKLIST Sheet 4 of 6 IP3 Status: YZJ NEý UD Area Walk-By Checklist (AWC) AWC-023 Location:

Bldg. PA Floor El. 41'-0 Room, Area'SWEL Components:

SWELl-024 Photographs

  • ' 4 U L i u u iz. s r tu p iU V I U V V L d f 1 K)te: Tools on top of CCW tank EN-DC-168 REV 0 Engineering Report No IP-RPT-12-00039 Rev 0 Page D-108 of 192 ATTACHMENT 9.7 Sheet 5 of 6 Area Walk-By Checklist (AWC) AWC-023 Location:

Bldg. PA Floor El. 41'-0 Room, Area 1 SWEL Components:

SWELl -024 AREA WALK-BY CHECKLIST IP3 Status: YZ NF] UFI-I Note: loose hose laying on floor going to an upper elevation.

EN-DC-1 68 REV 0 Engineering Report No IP-RPT-12-00039 Rev 0, Page D-109 of 192 ATTACHMENT 9.7 AREA WALK-BY CHECKLIST Sheet 6 of 6 IP3 Status: YN NFI UlýArea Walk-By Checklist (AWC) AWC-023 Location:

Bldg. PA Floor El. 41'-0 Room, Area'SWEL Components:

SWELl-024 Note: Unrestrained ladder by the Appendix R safe shutdown ladder.Note: EN-DC-168 REV 0 Engineering Report No. IP-RPT-12-00039, Rev. 0, Page D-110 of 192 ATTACHMENT 9.7 AREA WALK-BY CHECKLIST Sheet I of 4 IP3 Status: Y-J ND UD Area Walk-By Checklist (AWC) AWC-024 Location:

Bldg. PA Floor El. 15'-0" Room, Area 1 RHR PUMP ROOM (CELL 31)SWEL Components:

SWELl-028 Instructions for Completing Checklist This checklist may be used to document the results of the Area Walk-By near one or more SWEL items. The space below each of the following questions may be used to record the results of judgments and findings.Additional space is provided at the end of this checklist for documenting other comments.1. Does anchorage of equipment in the area appear to be free of potentially adverse seismic conditions (if visible without necessarily opening cabinets)?

Yes, anchorage of equipment in the area appears to be free of potentially adverse seismic conditions.

Y] ND UEI N/AD-1 2. Does anchorage of equipment in the area appear to be free of significant degraded conditions?

Yes, anchorage of equipment in the area appears to be free of significant degraded conditions.

Y[ ND UID N/AD 3. Based on a visual inspection from the floor, do the cable/conduit raceways and HVAC ducting appear to be free of potentially adverse seismic conditions (e.g., condition of supports is adequate and fill conditions of cable trays appear to be inside acceptable limits)?Y[E ND UD N/AD--Yes, based on a visual inspection from the floor, the cable/conduit raceways and HVAC ducting appears to be free of potentially adverse seismic condibons.

If the room in which the SWEL item is located is very large (e.g., Turbine Hall), the area selected should be described.

This selected area should be based on judgment, e.g., on the order of about 35 feet fi-om the SWEL item.EN-DC-168 REV 0 Engineering Report No. IP-RPT-12-00039, Rev. 0, Page D-111 of 192 ATTACHMENT 9.7 AREA WALK-BY CHECKLIST Sheet 2 of 4 IP3 Status: YrZ NFD UD Area Walk-By Checklist (AWC) AWC-024 Location:

Bldg. PA Floor El. 15'-0" Room, Area 1 RHR PUMP ROOM (CELL 31)SWEL Components:

SWELl -028 4. Does it appear that the area is free of potentially adverse seismic YEZ NDI ULI N/AD-spatial interactions with other equipment in the area (e.g., ceiling tiles and lighting)?

Yes, it appears that the area is free of potentially adverse seismic spatial interactions with other equipment in the area.5. Does it appear that the area is free of potentially adverse seismic interactions that could cause flooding or spray in the area?Yes, it appears that the area is free of potentially adverse seismic interactions that could cause flooding or spray in the area.YE NDI U[:] N/A-6. Does it appear that the area is free of potentially adverse seismic interactions that could cause a fire in the area?Yes, it appears that the area is free of potentially adverse seismic interactions that could cause a fire in the area.7. Does it appear that the area is free of potentially adverse seismic interactions associated with housekeeping practices, storage of portable equipment, and temporary installations (e.g., scaffolding, lead shielding)?

Yes, it appears that the area is free of potentially adverse seismic interactions associated with housekeeping practices, storage of portable equipment, and temporary installations.

YN ND UD N/AD1 YEA NDI UD1 N/AD EN-DC-168 REV 0 Engineering Report No. IP-RPT-12-00039, Rev 0, Page D-112 of 192 ATTACHMENT 9.7 AREA WALK-BY CHECKLIST Sheet 3 of 4 IP3 Status: YE N--1 U[--Area Walk-By Checklist (AWC) AWC-024 Location:

Bldg. PA Floor El. 15'-0" Room, Area 1 RHR PUMP ROOM (CELL 31)SWEL Components:

SWELl -028 8. Have you looked for and found no other seismic conditions that could adversely affect the safety functions of the equipment in the area?Yes, we have looked for and found no other seismic conditions that could adversely affect the safety functions of the equipment in the area.Y[M NEI U[]Comments (Additional pages may be added as necessary)

Reference:

IP3 SWELl-028_ _ __ a-Date: 10/22/12 Evaluated by: Maggie Farah KaiLo /c 10/22/12 EN-DC-168 REV 0 Engineering Report No IP-RPT-12-00039, Rev 0 Page D-113 of 192 ATTACHMENT 9.7 AREA WALK-BY CHECKLIST Sheet 4 of 4 IP3 Status. YE] ND UD Area Walk-By Checklist (AWC) AWC-024 Location:

Bldg, PA Floor El. 15'-0" Room, Area' RHR PUMP ROOM (CELL 31)SWEL Components:

SWELl -028 Photographs Note: piing with an unsunoorted lenath of Note: approximately 25 to 30 ft.EN-DC-168 REV 0 Engineering Report No. IP-RPT-12-00039, Rev. 0, Page D-114 of 192 ATTACHMENT 9.7 AREA WALK-BY CHECKLIST Sheet 1 of 6 IP3 Status: YE NEI U-I Area Walk-By Checklist (AWC) AWC-025 Location:

Bldg. PA Floor El. 73'-0" Room, Area 1 SWEL Components:

SWELl -092, 098, 093 Instructions for Completing Checklist This checklist may be used to document the results of the Area Walk-By near one or more SWEL items. The space below each of the following questions may be used to record the results of judgments and findings.Additional space is provided at the end of this checklist for documenting other comments.1. Does anchorage of equipment in the area appear to be free of YE ND-- ULI N/AD potentially adverse seismic conditions (if visible without necessarily opening cabinets)?

TR-4004 support base plate is missing two out of four anchor bolts.This is typical of all four base plates and based on the size of the cabinet, it is judged that this configuration is adequate for applied seismic loading.2. Does anchorage of equipment in the area appear to be free of YDI NE UD N/AD significant degraded conditions?

Electric heat tracing cabinet support base plates and anchor bolts are severely corroded.

The Unistrut support column has been welded to the stair stringer to provide additional support. CR-IP3-2012-03595 documents this condition.

LB-19 has evaluated this condition.

3. Based on a visual inspection from the floor, do the cable/conduit YE ND- UD N/AD raceways and HVAC ducting appear to be free of potentially adverse seismic conditions (e.g., condition of supports is adequate and fill conditions of cable trays appear to be inside acceptable limits)?Fluorescent tubes need to be restrained.

This is a not a seismic adverse condition since equipment in the area are noted as hard targets. CR-IP3-2012-03595 has been written to remedy this condition.

The ladders at the entrance to the Nonregenerative Heat Exchanger Room need to be secured. This is not a seismic adverse concern since the ladders are not near any sensitive equipment.

Good practice is to tie the ladders to the support frame. CR-IP3-2012-03501 has been written to investigate this condition.

The following observation relate to duct FR-DF-40: " The vise grips used to hold the seams on duct need to be replaced with a permanent corrective solution." One wall of the above duct is totally separated from the vertical comer and is flapping freely.The wall of the duct is light in weight and will not damage the nearby boric acid tank. In addition, total separation from the duct is unlikely;therefore, this is judged to have no adverse seismic condition.

CR-IP3-2012-03595 has been written to correct these conditions.

If the room in which the SWEL item is located is very large (e.g., Turbine Hall), the area selected should be described.

This selected area should be based on judgment.

e.g., on the order of about 35 feet fr'om the SWEL item.EN-DC-168 REV 0 Engineering Report No. IP-RPT-12-00039, Rev. 0, Page D-115 of 192 ATTACHMENT 9.7 AREA WALK-BY CHECKLIST Sheet 2 of 6 IP3 Status: YEZ NO UFI Area Walk-By Checklist (AWC) AWC-025 Location:

Bldg. PA Floor El. 73'-0" Room, Area 1 SWEL Components:

SWELl -092, 098, 093 4. Does it appear that the area is free of potentially adverse seismic YE- NEI U[-] N/AD spatial interactions with other equipment in the area (e.g., ceiling tiles and lighting)?

Fluorescent tubes need to be restrained.

This is a not a seismic adverse condition since equipment in the area are noted as hard targets. Good practice is to tie the bulbs to the fixture. CR-IP3-2012-03481 has been written to correct this condition.

5. Does it appear that the area is free of potentially adverse seismic interactions that could cause flooding or spray in the area?Yes, it appears that the area is free of potentially adverse seismic interactions that could cause flooding or spray in the area.6. Does it appear that the area is free of potentially adverse seismic interactions that could cause a fire in the area?Yes, it appears that the area is free of potentially adverse seismic interactions that could cause a fire in the area.7. Does it appear that the area is free of potentially adverse seismic interactions associated with housekeeping practices, storage of portable equipment, and temporary installations (e.g., scaffolding, lead shielding)?

A pipe hanger is close (approx Y 2") to a conduit. See photo for location.The seismically designed conduit is very rigid and will have less than 0. 1 "seismic displacement.

The nearby hanger rod is for dead weight only but the pipe is seismically restrained so the lateral displacement will also be small. The Y" clearance is judged to be acceptable.

In the South-east comer of the room there are pallets of drums and a vacuum that are all unrestrained.

The drums and vacuum are remote from any equipment and this is not judged to be an adverse seismic condition.

CR-IP3-2012-03501 has been written to address this condition.

There is a hot water heater adjacent to the concrete column near Boric Acid Tank 31 which does not have any apparent anchorage.

CR-IP3-2012-03595 has been written to investigate this condition.

Through wall room air conditioners are hung for gravity loading but do not appear to have any lateral restraint for seismic loading. Since there is no safety related equipment nearby, there is no adverse spatial interaction.

YN NDI U[] N/AD YE NDI UD- N/AD YDI NM uD- N/AD-EN-DC-168 REV 0 Engineering Report No. IP-RPT-12-00039, Rev. 0, Page D-116 of 192 ATTACHMENT 9.7 AREA WALK-BY CHECKLIST Sheet 3 of 6 IP3 Status: YrZ] NEI U[-Area Walk-By Checklist (AWC) AWC-025 Location:

Bldg. PA Floor El. 73'-0" Room, Area'SWEL Components:

SWELl -092, 098, 093 8. Have you looked for and found no other seismic conditions that could YEJ NEI UDF]adversely affect the safety functions of the equipment in the area?Yes we have looked for and found no other seismic conditions that could adversely affect the safety functions of the equipment in the area.Comments (Additional pages may be added as necessary)

One light bulb above CC Surge Tank #31 needs to be replaced.Date: 10/22/2012 Evaluated by: Stephen Yuan__ Date: 10/22/2012 Paul Huebsch EN-DC-168 REV 0 Engineering Report No IP-RPT-12-00039, Rev 0 Page D-117 of 192 ATTACHMENT 9.7 AREA WALK-BY CHECKLIST Sheet 4 of 6 IP3 Status: YE] ND UEi Area Walk-By Checklist (AWC) AWC-025 Location:

Bldg. PA Floor El. 73'-0" Room, Area_SWEL Components:

SWELl -092, 098, 093 Photographs 1 Note: t~ase piate wim IWo out or rour ancnor DOlS in place.rioxe: L~iectnc neat tracing caritnet vase piate roye: tlectric neat tracing c, inside of curbed area.Note: Unsecured lad heat exchanger room nregerative EN-DC-168 REV 0 Engineenng Report No I P-RPT-12-00039.

Rev 0 Page D-118 of 192 ATTACHMENT 9.7 AREA WALK-By CHECKLIST Sheet 5 of 6 Area Walk-By Checklist (AWC) AWC-025 IP3 Status: YMI Nn~ uFil Location:

Bldg. PA FloorEl. 73-0' Room,0Area SWEL Components:

SWEL1 -092. 098, 093 Note: seam.EN-DC-168 REV 0 Engineering Report No IP-RPT-12-00039.

Rev 0. Page D-119 of 192 ATTACHMENT 9.7 AREA WALK-BY CHECKLIST Sheet 6 of 6 IP3 Status: YZEj NFI-- UF Area Walk-By Checklist (AWC) AWC-025 Location:

Bldg. PA Floor El. 73'-0" Room, Area'SWEL Components:

SWELl -092. 098. 093 EN-DC-1 68 REV 0 Engineering Report No. IP-RPT-12-00039, Rev. 0, Page D-120 of 192 ATTACHMENT 9.7 AREA WALK-BY CHECKLIST Sheet 1 of 4 IP3 Status: YE ND UD Area Walk-By Checklist (AWC) AWC-026 Location:

Bldg. PA Floor El. 73'-0" Room, Area 1 SWEL Components:

SWELl -039 Instructions for Completing Checklist This checklist may be used to document the results of the Area Walk-By near one or more SWEL items. The space below each of the following questions may be used to record the results of judgments and findings.Additional space is provided at the end of this checklist for documenting other comments.1. Does anchorage of equipment in the area appear to be free of potentially adverse seismic conditions (if visible without necessarily opening cabinets)?

Yes anchorage of equipment in the area appears to be free of potentially adverse seismic conditions.

YN ND- UD- N/AD]2. Does anchorage of equipment in the area appear to be free of significant degraded conditions?

Yes anchorage of equipment in the area appears to be free of significant degraded conditions.

YZ NDI UD] 3. Based on a visual inspection from the floor, do the cable/conduit raceways and HVAC ducting appear to be free of potentially adverse seismic conditions (e.g., condition of supports is adequate and fill conditions of cable trays appear to be inside acceptable limits)?Y[9 ND-] UD_ Yes based on a visual inspection from the floor, the cable/conduit raceways and HVAC ducting appears to be free of potentially adverse seismic conditions.

I If the room in which the SWEL item is located is very large (e.g., Turbine Hall), the area selected should be described.

This selected area should be based on judgment, e.g., on the order of about 35 feet fiom the SWEL item.EN-DC-168 REV 0 Engineering Report No. IP-RPT-12-00039, Rev. 0, Page D-121 of 192 ATTACHMENT 9.7 AREA WALK-BY CHECKLIST Sheet 2 of 4 IP3 Status: YZ NDl UR Area Walk-By Checklist (AWC) AWC-026 Location:

Bldg. PA Floor El. 73'-0" Room, Area 1 SWEL Components:

SWELI-039 4. Does it appear that the area is free of potentially adverse seismic YE NEI U[-- N/AD1 spatial interactions with other equipment in the area (e.g., ceiling tiles and lighting)?

Yes, it appears that the area is free of potentially adverse seismic spatial interactions with other equipment in the area.5. Does it appear that the area is free of potentially adverse seismic interactions that could cause flooding or spray in the area?Yes, it appears that the area is free of potentially adverse seismic interactions that could cause flooding or spray in the area.YN NDI UD- N/AD 6. Does it appear that the area is free of potentially adverse seismic interactions that could cause a fire in the area?Yes, it appears that the area is free of potentially adverse seismic interactions that could cause a fire in the area.YN NDI u[D N/AD]7. Does it appear that the area is free of potentially adverse seismic interactions associated with housekeeping practices, storage of portable equipment, and temporary installations (e.g., scaffolding, lead shielding)?

Yes it appears that the area is free of potentially adverse seismic interactions associated with housekeeping practices, storage of portable equipment, and temporary installations.

YE ND UD1 N/AD-EN-DC-168 REV 0 Engineering Report No. IP-RPT-12-00039, Rev. 0, Page D-122 of 192 ATTACHMENT 9.7 AREA WALK-BY CHECKLIST Sheet 3 of 4 IP3 Status: Y[J NF] Ur Area Walk-By Checklist (AWC) AWC-026 Location:

Bldg. PA Floor El. 73'-0" Room, Area 1 SWEL Components:

SWELl -039 8. Have you looked for and found no other seismic conditions that could YE NO U--adversely affect the safety functions of the equipment in the area?Yes we have looked for and found no other seismic conditions that could adversely affect the safety functions of the equipment in the area.Comments (Additional pages may be added as necessary)

Evaluated by: Stephen Yuan Date: 10/22/2012

_Date: 10/22/2012 Paul Huebsch EN-DC-168 REV 0 Engineering Report No. IP-RPT-12-00039, Rev. 0, Page D-123 of 192 ATTACHMENT 9.7 AREA WALK-BY CHECKLIST Sheet 4 of 4 IP3 Status: Y ] N-- UD--Area Walk-By Checklist (AWC) AWC-026 Location:

Bldg. PA Floor El. 73'-0" Room, Area'SWEL Components:

SWELl -039 Photographs No photos of this area Note: Note: EN-DC-168 REV 0 Engineering Report No. IP-RPT-12-00039, Rev. 0, Page D-124 of 192 ATTACHMENT 9.7 AREA WALK-BY CHECKLIST Sheet I of 4 IP3 Status: Y[Z NDI UF-Area Walk-By Checklist (AWC) AWC-027 Location:

Bldg. PA Floor El. 15'-0" Room, Area' RHR PUMP ROOM (CELL32)SWEL Components:

SWELl -029 Instructions for Completing Checklist This checklist may be used to document the results of the Area Walk-By near one or more SWEL items. The space below each of the following questions may be used to record the results of judgments and findings.Additional space is provided at the end of this checklist for documenting other comments.1. Does anchorage of equipment in the area appear to be free of potentially adverse seismic conditions (if visible without necessarily opening cabinets)?

Yes, anchorage of equipment in the area appears to be free of potentially adverse seismic conditions.

2. Does anchorage of equipment in the area appear to be free of significant degraded conditions?

Yes, anchorage of equipment in the area appears to be free of significant degraded conditions.

3. Based on a visual inspection from the floor, do the cable/conduit raceways and HVAC ducting appear to be free of potentially adverse seismic conditions (e.g., condition of supports is adequate and fill conditions of cable trays appear to be inside acceptable limits)?Observed a waste disposal liquid pipe (approximately 4" in diameter)coming out of the north wall then penetrates the floor with an unsupported length of approximately 25 ft to 30 ft (see attached photo).LB-12 evaluates this condition.

YZ NEI UD N/A-YZ NDI U-I N/AD-YO NZ UD N/AD 4. Does it appear that the area is free of potentially adverse seismic spatial interactions with other equipment in the area (e.g., ceiling tiles and lighting)?

Y[M NDI UFD N/AD-Yes, it appears that the area is free of potentially adverse seismic spatial interactions with other equipment in the area.'If the room in which the SWEL item is located is very large (e.g., Turbine Hall), the area selected should be described.

This selected area should be based on judgment, e.g., on the order of about 35 feet from the SWEL item.EN-DC-168 REV 0 Engineering Report No. IP-RPT-12-00039, Rev. 0, Page D-125 of 192 ATTACHMENT 9.7 AREA WALK-BY CHECKLIST Sheet 2 of 4 1P3 Status: YZ ND-1 UD Area Walk-By Checklist (AWC) AWC-027 Location:

Bldg. PA Floor El. 15'-0" Room, Area 1 RHR PUMP ROOM (CELL32)SWEL Components:

SWELl -029 5. Does it appear that the area is free of potentially adverse seismic Y[ ND UrD N/AD1 interactions that could cause flooding or spray in the area?Yes. it appears that the area is free of potentially adverse seismic interactions that could cause flooding or spray in the area.6. Does it appear that the area is free of potentially adverse seismic Y[ NDI LiD- N/A[D]interactions that could cause a fire in the area?Yes, it appears that the area is free of potentially adverse seismic interactions that could cause a fire in the area.7. Does it appear that the area is free of potentially adverse seismic Y] NDI uDl N/AD-interactions associated with housekeeping practices, storage of portable equipment, and temporary installations (e.g., scaffolding, lead shielding)?

Yes, it appears that the area is free of potentially adverse seismic interactions associated with housekeeping practices, storage of portable equipment, and temporary installations.

8. Have you looked for and found no other seismic conditions that could YDI NDI U-adversely affect the safety functions of the equipment in the area?Yes, we have looked for and found no other seismic conditions that could adversely affect the safety functions of the equipment in the area.EN-DC-168 REV 0 Engineering Report No. IP-RPT-12-00039, Rev. 0, Page D-126 of 192 ATTACHMENT 9.7 Sheet 3 of 4 Area Walk-By Checklist (AWC) AWC-027 Location:

Bldg. PA Floor El. 15'-0" SWEL Components:

SWELl -029 Comments (Additional pages may be added as necE

Reference:

IP3 SWEL1-029 LB-12 AREA WALK-BY CHECKLIST IP3 Status: Y- NIh U--Room, Area 1 RHR PUMP ROOM (CELL32)Date: 10/22/12 Evaluated by: MagQie Farah Kai Lo /C- 6 ' 10122112 EN-DC-168 REV 0 Engineering Report No IP-RPT-12-00039.

Rev 0 Page D-127 of 192 ATTACHMENT 9.7 AREA WALK-By CHECKLIST Sheet 4 of 4 IP3 Status: Y[ ND1 UEi Area Walk-By Checklist (AWC) AWC-027 Location:

Bldg. PA Floor El, 15'-0" Room, Area 1 RHR PUMP ROOM (CELL32)SWEL Components:

SWELl -029 Photographs Note: piping with an unsupported length of approximately 25 ft to 30 ft Note: EN-DC-168 REV 0 Engineering Report No. IP-RPT-12-00039, Rev. 0, Page D-128 of 192 ATTACHMENT 9.7 AREA WALK-BY CHECKLIST Sheet I of 4 IP3 Status: Y[Z ND UD Area Walk-By Checklist (AWC) AWC-028 Location:

Bldg. PA Floor El. 55'-0" Room, Area 1 SWEL Components:

SWELl-011, 009 Instructions for Completing Checklist This checklist may be used to document the results of the Area Walk-By near one or more SWEL items. The space below each of the following questions may be used to record the results of judgments and findings.Additional space is provided at the end of this checklist for documenting other comments.1. Does anchorage of equipment in the area appear to be free of potentially adverse seismic conditions (if visible without necessarily opening cabinets)?

Camera mounted on post with base plate which has no anchor bolts and stands adjacent to the stairway.

CR-IP3-2012-03565 has been written to correct this condition.

LB-12 was performed to evaluate the condition.

2. Does anchorage of equipment in the area appear to be free of significant degraded conditions?

Yes anchorage of equipment in the area appears to be free of significant degraded conditions.

YD-- NO U[-D N/AD YtZ NEI uD N/AD 3. Based on a visual inspection from the floor, do the cable/conduit raceways and HVAC ducting appear to be free of potentially adverse seismic conditions (e.g., condition of supports is adequate and fill conditions of cable trays appear to be inside acceptable limits)?Yes based on a visual inspection from the floor, the cable/conduit raceways and HVAC ducting appears to be free of potentially adverse seismic conditions.

YE NDI UD1 N/A[--4. Does it appear that the area is free of potentially adverse seismic spatial interactions with other equipment in the area (e.g., ceiling tiles and lighting)?

YD NO UD N/AD-See question #1.I If the room in which the SWEL item is located is vert, large (e.g., Turbine Hall), the area selected should be described.

This selected area should be based on judgment, e.g.. on the order of about 35 feet from the SWEL item.EN-DC-168 REV 0 Engineering Report No. IP-RPT-12-00039, Rev. 0, Page D-129 of 192 ATTACHMENT 9.7 AREA WALK-BY CHECKLIST Sheet 2 of 4 IP3 Status: Y[N ND UD Area Walk-By Checklist (AWC) AWC-028 Location:

Bldg. PA Floor El. 55'-0" Room, Area1 SWEL Components:

SWELl-011, 009 5.Does it appear that the area is free of potentially adverse seismic interactions that could cause flooding or spray in the area?Y-- NDI ui N/AD Yes, it appears that the area is free of potentially adverse seismic interactions that could cause flooding or spray in the area.6. Does it appear that the area is free of potentially adverse seismic interactions that could cause a fire in the area?Yes, it appears that the area is free of potentially adverse seismic interactions that could cause a fire in the area.Y0 NDI UD N/AD1 7. Does it appear that the area is free of potentially adverse seismic interactions associated with housekeeping practices, storage of portable equipment, and temporary installations (e.g., scaffolding, lead shielding)?

Various housekeeping practices were identified:

Loose padlocks left in the area. Because of the small mass of the padlocks and there location, this is not considered an adverse seismic condition.

It is considered to be a housekeeping problem.Unsecured tool boxes and unlocked electrical cabinet noted.This condition exists remote from equipment which might be affected by a seismic event.Fluorescent tube missing near transformer

32. This is not an adverse seismic condition.

Y[ NDI UD N/AD CR-IP3-2012-03501 tracks the resolutions.

8. Have you looked for and found no other seismic conditions that could YE NDI uD-adversely affect the safety functions of the equipment in the area?Yes we have looked for and found no other seismic conditions that could adversely affect the safety functions of the equipment in the area.Comments (Additional pages may be added as necessary)

EN-DC-168 REV 0 Engineering Report No. IP-RPT-12-00039, Rev. 0, Page D-130 of 192 ATTACHMENT 9.7 AREA WALK-BY CHECKLIST Sheet 3 of 4 IP3 Status: YO ND- UP Area Walk-By Checklist (AWC) AWC-028 Location:

Bldg. PA Floor El. 55'-0" Room, Area 1 SWEL Components:

SWELl-011, 009 Date: 10/22/2012 Evaluated by: Stephen Yuan Date: 10/22/2012 EN-DC-168 REV 0 Engineering Report No. IP-RPT-12-00039, Rev. 0, Page D-131 of 192 ATTACHMENT 9.7 AREA WALK-BY CHECKLIST Sheet 4 of 4 IP3 Status: YE NEI Ui--Area Walk-By Checklist (AWC) AWC-028 Location:

Bldg. PA Floor El. 55'-0" Room, Area'SWEL Components:

SWELl-011, 009 Photographs Note: Loose padlocks on top of cabinet Note: Unsecured tool box on top of cabinet and cabinet door not closed.EN-DC-168 REV 0 Engineering Report No. IP-RPT-12-00039, Rev. 0, Page D-132 of 192 ATTACHMENT 9.7 AREA WALK-BY CHECKLIST Sheet 1 of 4 1P3 Status: YEZ NEI UE--Area Walk-By Checklist (AWC) AWC-029 Location:

Bldg. PA Floor El. 55'-0'" Room, Area 1 SWEL Components:

SWELl -087 Instructions for Completing Checklist This checklist may be used to document the results of the Area Walk-By near one or more SWEL items. The space below each of the following questions may be used to record the results of judgments and findings.Additional space is provided at the end of this checklist for documenting other comments.1. Does anchorage of equipment in the area appear to be free of potentially adverse seismic conditions (if visible without necessarily opening cabinets)?

Appendix R cabinet EBR-22-PAB is not snug against the support.There is a gap between the back of the cabinet and the supporting surface at the top. The nut inside the Unistrut channel is still engaged and the bolt is still there. SWEs judged that the EBR will not fall during a seismic event.CR-IP3-2012-03557 has been written to evaluate this condition to properly secure this item.2. Does anchorage of equipment in the area appear to be free of significant degraded conditions?

Yes anchorage of equipment in the area appears to be free of significant degraded conditions.

YD NZ UD1 N/A--YE NEJ UDl N/A--3. Based on a visual inspection from the floor, do the cable/conduit raceways and HVAC ducting appear to be free of potentially adverse seismic conditions (e.g., condition of supports is adequate and fill conditions of cable trays appear to be inside acceptable limits)?YE ND UD N/AD Yes based on a visual inspection from the floor, the cable/conduit raceways and HVAC ducting appears to be free of potentially adverse seismic conditions.

If the room in which the SWEL item is located is ver, large (e.g., Turbine Hall), the area selected should be described.

This selected area should be based on judgment, e.g.. on the order of about 35 feet from the SWEL item.EN-DC-1 68 REV 0 Engineering Report No. IP-RPT-12-00039, Rev. 0, Page D-133 of 192 ATTACHMENT 9.7 AREA WALK-BY CHECKLIST Sheet 2 of 4 IP3 Status: YE ND I UFD]Area Walk-By Checklist (AWC) AWC-029 Location:

Bldg. PA Floor El. 55'-0" Room, Area 1 SWEL Components:

SWEL1 -087 4. Does it appear that the area is free of potentially adverse seismic Y[ NDi U-I N/AD-spatial interactions with other equipment in the area (e.g., ceiling tiles and lighting)?

Yes, it appears that the area is free of potentially adverse seismic spatial interactions with other equipment in the area.5. Does it appear that the area is free of potentially adverse seismic interactions that could cause flooding or spray in the area?Yes, it appears that the area is free of potentially adverse seismic interactions that could cause flooding or spray in the area.YEZ NDI UDI N/AD-6. Does it appear that the area is free of potentially adverse seismic interactions that could cause a fire in the area?Yes, it appears that the area is free of potentially adverse seismic interactions that could cause a fire in the area.YE1 NDI UD- N/ADI 7. Does it appear that the area is free of potentially adverse seismic interactions associated with housekeeping practices, storage of portable equipment, and temporary installations (e.g., scaffolding, lead shielding)?

YDI NM UDI N/AD-Various housekeeping practices were identified:

-Loose cart found in the area.CR-IP3-2012-03501 tracks the resolution.

-Loose part found in the area near EBR-22-PAB CR-IP3-2012-03501 tracks the resolution.

EN-DC-168 REV 0 Engineering Report No. IP-RPT-12-00039, Rev. 0, Page D-134 of 192 ATTACHMENT 9.7 AREA WALK-BY CHECKLIST Sheet 3 of 4 1P3 Status: YE NDI UD-Area Walk-By Checklist (AWC) AWC-029 Location:

Bldg. PA Floor El. 55'-0" Room, Area 1 SWEL Components:

SWELI-087 8. Have you looked for and found no other seismic conditions that could Y[E NEI UD adversely affect the safety functions of the equipment in the area?Yes we have looked for and found no other seismic conditions that could adversely affect the safety functions of the equipment in the area.Comments (Additional pages may be added as necessary)

Evaluated by: Stephen Yuan Date: 10/22/2012

_____Date:

10/22/2012 Paul Huebsch EN-DC-168 REV 0 Engineering Report No IP-RPT-12-00039, Rev 0, Page D-135 of 192 ATTACHMENT 9.7 AREA WALK-BY CHECKLIST Sheet 4 of 4 IP3 Status: YZ NFI U-Area Walk-By Checklist (AWC) AWC-029 Location:

Bldg PA Floor El. 55-0" Room, Area_SWEL Components:

SWELl -087 Photographs L I Note: EN-DC-168 REV 0 Engineering Report No. IP-RPT-12-00039, Rev. 0, Page D-136 of 192 ATTACHMENT 9.7 AREA WALK-BY CHECKLIST Sheet 1 of 4 IP3 Status: YEr- NEI uLI Area Walk-By Checklist (AWC) AWC-030 Location:

Bldg. PA Floor El. 55'-0" Room, Area 1 SWEL Components:

SWELl -027 Instructions for Completing Checklist This checklist may be used to document the results of the Area Walk-By near one or more SWEL items. The space below each of the following questions may be used to record the results of judgments and findings.Additional space is provided at the end of this checklist for documenting other comments.1. Does anchorage of equipment in the area appear to be free of potentially adverse seismic conditions (if visible without necessarily opening cabinets)?

Pipes connected to and near valve AC-757E have long unsupported length in the vertical direction This condition is shown on drawing 9321-F-55743 for line no. 641. The piping is seismic class l and has been analyzed and supported seismically.

2. Does anchorage of equipment in the area appear to be free of significant degraded conditions?

Yes anchorage of equipment in the area appears to be free of significant degraded conditions.

YE N[-] UE- N/A--Y[Z NEI U-- N/A-3. Based on a visual inspection from the floor, do the cable/conduit raceways and HVAC ducting appear to be free of potentially adverse seismic conditions (e.g., condition of supports is adequate and fill conditions of cable trays appear to be inside acceptable limits)?YE NEI U-- N/AD1 Yes based on a visual inspection from the floor, the cable/conduit raceways and HVAC ducting appears to be free of potentially adverse seismic conditions.

'If the room in which the SWEL item is located is reri- large (e.g., Turbine Hall), the area selected should be described.

This selected area should be based on judgment, e.g., on the order of about 35 feet from the SWEL item.EN-DC-168 REV 0 Engineering Report No. IP-RPT-12-00039, Rev. 0, Page D-137 of 192 ATTACHMENT 9.7 AREA WALK-BY CHECKLIST Sheet 2 of 4 IP3 Status: YD- NDI UN Area Walk-By Checklist (AWC) AWC-030 Location:

Bldg. PA Floor El. 55'-0" Room, Area'SWEL Components:

SWELl -027 4. Does it appear that the area is free of potentially adverse seismic spatial interactions with other equipment in the area (e.g., ceiling tiles and lighting)?

Yes, it appears that the area is free of potentially adverse seismic spatial interactions with other equipment in the area.YZ- NDI U-D N/ADI 5. Does it appear that the area is free of potentially adverse seismic interactions that could cause flooding or spray in the area?The area is free of potentially adverse seismic interactions that could cause flooding or spray in the area.Y[ NDI UED N/ADI 6. Does it appear that the area is free of potentially adverse seismic interactions that could cause a fire in the area?Yes, it appears that the area is free of potentially adverse seismic interactions that could cause a fire in the area.YE NDJ uDl N/ADl 7. Does it appear that the area is free of potentially adverse seismic interactions associated with housekeeping practices, storage of portable equipment, and temporary installations (e.g., scaffolding, lead shielding)?

Yes it appears that the area is free of potentially adverse seismic interactions associated with housekeeping practices, storage of portable equipment, and temporary installations.

Y-- NDI uD1 N/ADI EN-DC-168 REV 0 Engineering Report No. IP-RPT-12-00039, Rev. 0, Page D-138 of 192 ATTACHMENT 9.7 AREA WALK-By CHECKLIST Sheet 3 of 4 1P3 Status: Y-F NO U[Area Walk-By Checklist (AWC) AWC-030 Location:

Bldg. PA Floor El. 55'-0" Room, Area 1 SWEL Components:

SWELl -027 8. Have you looked for and found no other seismic conditions that could YIZ NEl U--adversely affect the safety functions of the equipment in the area?Yes we have looked for and found no other seismic conditions that could adversely affect the safety functions of the equipment in the area.Comments (Additional pages may be added as necessary)

E a b-Y_ _ _ _ _-_ _ Date: 10/22/2012 Evaluated by: Stephe Yuan Da-e_________________________________________Date:

10122/2012 Paul Huebsch EN-DC-168 REV 0 Engineering Report No IP-RPT-12-00039 Rev 0, Page D-139 of 192 ATTACHMENT 9.7 AREA WALK-BY CHECKLIST Sheet 4 of 4 IP3 Status: Y[O NEI UN Area Walk-By Checklist (AWC) AWC-030 Location:

Bldg. PA Floor El. 55'-0" Room, Area'SWEL Components:

SWELl -027 Photographs Note: Pipes connected to and near valve AC-757E Note: have long unsupported length in the vertical direction and are in contact near the ceiling.EN-DC-168 REV 0 Engineering Report No. IP-RPT-12-00039, Rev. 0, Page D-140 of 192 ATTACHMENT 9.7 AREA WALK-BY CHECKLIST Sheet I of 4 1P3 Status: YEN NEI UEZ Area Walk-By Checklist (AWC) AWC-031 Location:

Bldg. PA Floor El. 34'-0" Room, Area' SAFETY INJECTION PUMP ROOM SWEL Components:

SWELl -021 Instructions for Completing Checklist This checklist may be used to document the results of the Area Walk-By near one or more SWEL items. The space below each of the following questions may be used to record the results of judgments and findings.Additional space is provided at the end of this checklist for documenting other comments.1. Does anchorage of equipment in the area appear to be free of potentially adverse seismic conditions (if visible without necessarily opening cabinets)?

Yes, anchorage of equipment in the area appears to be free of potentially adverse seismic conditions.

YE NEI U-] N/A[l-2. Does anchorage of equipment in the area appear to be free of significant degraded conditions?

Yes, anchorage of equipment in the area appears to be free of significant degraded conditions.

YE NEI U-- N/A--3. Based on a visual inspection from the floor, do the cable/conduit raceways and HVAC ducting appear to be free of potentially adverse seismic conditions (e.g., condition of supports is adequate and fill conditions of cable trays appear to be inside acceptable limits)?Y[Z NEI] UE N/A[--Yes, based on a visual inspection from the floor, the cable/conduit raceways and HVAC ducting appears to be free of potentially adverse seismic condibons.

If the room in which the SWEL item is located is very large (e.g., Turbine Hall), the area selected should be described.

This selected area should be based oni judgment, e.g., on the order of about 35 feet friom the SWEL item.EN-DC-168 REV 0 Engineering Report No. IP-RPT-12-00039, Rev. 0, Page D-141 of 192 ATTACHMENT 9.7 AREA WALK-BY CHECKLIST Sheet 2 of 4 IP3 Status: Y-- ND- UD]Area Walk-By Checklist (AWC) AWC-031 Location:

Bldg. PA Floor El. 34'-0" Room, Area 1 SAFETY INJECTION PUMP ROOM SWEL Components:

SWELl -021 4. Does it appear that the area is free of potentially adverse seismic YE N[D] UI-- N/AD spatial interactions with other equipment in the area (e.g., ceiling tiles and lighting)?

Yes, it appears that the area is free of potentially adverse seismic spatial interactions with other equipment in the area.5. Does it appear that the area is free of potentially adverse seismic interactions that could cause flooding or spray in the area?Yes, it appears that the area is free of potentially adverse seismic interactions that could cause flooding or spray in the area.YE NEI UD N/A[:]6. Does it appear that the area is free of potentially adverse seismic interactions that could cause a fire in the area?Yes, it appears that the area is free of potentially adverse seismic interactions that could cause a fire in the area.7. Does it appear that the area is free of potentially adverse seismic interactions associated with housekeeping practices, storage of portable equipment, and temporary installations (e.g., scaffolding, lead shielding)?

Observed a brush, tape and a filter resting, unrestrained on a shelf located on the south wall of the room between Sl Pumps 31 and 32 (see attached photo). During a seismic event these items may dislodge or act as missile and strike nearby components.

This is addressed in CR-IP3-2012-03501.

YE ND U-- N/AD-YE] NE U-- N/ADI EN-DC-168 REV 0 Engineering Report No. IP-RPT-12-00039, Rev. 0, Page D-142 of 192 ATTACHMENT 9.7 AREA WALK-BY CHECKLIST Sheet 3 of 4 IP3 Status: YO NEI UEZ Area Walk-By Checklist (AWC) AWC-031 Location:

Bldg. PA Floor El. 34'-0" Room, Area 1 SAFETY INJECTION PUMP ROOM SWEL Components:

SWELl -021 8. Have you looked for and found no other seismic conditions that could YE NEI UE]adversely affect the safety functions of the equipment in the area?Yes, we have looked for and found no other seismic conditions that could adversely affect the safety functions of the equipment in the area.Comments (Additional pages may be added as necessary)

Evaluated by: Maggie Farah Date: 10/22/12 Kai Lo /-'~ 10/22/12 EN-DC-168 REV 0 Engineering Report No. IP-RPT-12-00039.

Rev. 0, Page D-143 of 192 ATTACHMENT 9.7 AREA WALK-BY CHECKLIST Sheet 4 of 4 IP3 Status: Y[Z ND- ULIJ Area Walk-By Checklist (AWC) AWC-031 Location:

Bldg. PA FloorEl. 34'-0" Room,Area 1 SAFETY INJECTION PUMP ROOM SWEL Comnonents:

SWELl-021 Photographs EN-DC-168 REV 0 Engineering Report No. IP-RPT-12-00039, Rev. 0, Page D-144 of 192 ATTACHMENT 9.7 AREA WALK-BY CHECKLIST Sheet I of 4 IP3 Status: Y] ND UD Area Walk-By Checklist (AWC) AWC-032 Location:

Bldg. PA Floor El. 55'-0" Room, Area 1 SWEL Components:

SWEL1 -026 Instructions for Completing Checklist This checklist may be used to document the results of the Area Walk-By near one or more SWEL items. The space below each of the following questions may be used to record the results of judgments and findings.Additional space is provided at the end of this checklist for documenting other comments.1. Does anchorage of equipment in the area appear to be free of YEr NE-i Ur-- N/AD potentially adverse seismic conditions (if visible without necessarily opening cabinets)?

Yes anchorage of equipment in the area appears to be free of potentially adverse seismic conditions.

2. Does anchorage of equipment in the area appear to be free of significant degraded conditions?

Yes anchorage of equipment in the area appears to be free of significant degraded conditions.

YN ND UD] N/AD 3. Based on a visual inspection from the floor, do the cable/conduit raceways and HVAC ducting appear to be free of potentially adverse seismic conditions (e.g., condition of supports is adequate and fill conditions of cable trays appear to be inside acceptable limits)?Y[E ND- UD N/AD Yes based on a visual inspection from the floor, the cable/conduit raceways and HVAC ducting appears to be free of potentially adverse seismic conditions.

If the room in which the SWEL item is located is venr large (e.g., Turbine Hall), the area selected should be described.

This selected area should be based on judgment, e.g., on the order of about 35 feet frlom the SWEL item.EN-DC-168 REV 0 Engineering Report No. IP-RPT-12-00039, Rev. 0, Page D-145 of 192 ATTACHMENT 9.7 AREA WALK-BY CHECKLIST Sheet 2 of 4 IP3 Status: YZ NO UD-1 Area Walk-By Checklist (AWC) AWC-032 Location:

Bldg. PA Floor El. 55'-0" Room, Area 1 SWEL Components:

SWELI-026 4. Does it appear that the area is free of potentially adverse seismic Y[ NDI UD- N/AD-spatial interactions with other equipment in the area (e.g., ceiling tiles and lighting)?

Fluorescent tubes need to be restrained.

CR-IP3-2012-03481 has been written to remedy this condition.

5. Does it appear that the area is free of potentially adverse seismic interactions that could cause flooding or spray in the area?Area heater UH335 has threaded hot water piping which does not appear to be seismically supported.

Maximum span is approximately 15 feet for estimated 2" diameter pipe. Area heater UH334 has a similar condition but it is more remote from the equipment area.LB-14 was performed to analyze this condition.

6. Does it appear that the area is free of potentially adverse seismic interactions that could cause a fire in the area?Yes, it appears that the area is free of potentially adverse seismic interactions that could cause a fire in the area.YO NZ UD N/A-YE NDI uD N/AD 7. Does it appear that the area is free of potentially adverse seismic interactions associated with housekeeping practices, storage of portable equipment, and temporary installations (e.g., scaffolding, lead shielding)?

Screw driver left on Unistrut.

See photo. This is considered a housekeeping condition and not considered an adverse seismic condition.

Miscellaneous parts on top of panel. See photo. This is considered a housekeeping condition and not considered an adverse seismic condition.

CR-IP3-3012-03501 has been written to remedy this condition.

YN NDI UD N/ADl EN-DC-168 REV 0 Engineering Report No. IP-RPT-12-00039, Rev. 0, Page D-146 of 192 ATTACHMENT 9.7 AREA WALK-BY CHECKLIST Sheet 3 of 4 IP3 Status: Y[ ND-- UDI Area Walk-By Checklist (AWC) AWC-032 Location:

Bldg. PA Floor El. 55'-0" Room, Area 1 SWEL Components:

SWELl -026 8. Have you looked for and found no other seismic conditions that could YO NEI UI adversely affect the safety functions of the equipment in the area?Yes we have looked for and found no other seismic conditions that could adversely affect the safety functions of the equipment in the area.Comments (Additional pages may be added as necessary)

Reference:

LB-14 Evaluated by: Stephen Yuan Date: 10/22/2012

_Date: 10/22/2012 Paul Huebsch EN-DC-168 REV 0 Engineering Report No IP-RPT-12-00039.

Rev 0. Page D-147 of 192 ATTACHMENT 9.7 AREA WALK-BY CHECKLIST Sheet 4 of 4 IP3 Status: YE NF] UD Area Walk-By Checklist (AWC) AWC-032 Location:

Bldg. PA Floor El, 55'-0" SWEL Components:

SWELl -026 Photographs Room, Area 1 N~OW-. Ocrew unfver ten Uri unlisuL1 imotu; IVIisubufldIouN paas Uri top ui, ldizir EN-DC-168 REV 0 Engineering Report No. IP-RPT-12-00039, Rev. 0, Page D-148 of 192 ATTACHMENT 9.7 AREA WALK-BY CHECKLIST Sheet I of 4 1P3 Status: YN NI UF--Area Walk-By Checklist (AWC) AWC-033 Location:

Bldg. PAB FloorEl. 41'-0" Room,Area' SWEL Components:

SWEL2-001 Instructions for Completing Checklist This checklist may be used to document the results of the Area Walk-By near one or more SWEL items. The space below each of the following questions may be used to record the results of judgments and findings.Additional space is provided at the end of this checklist for documenting other comments.1. Does anchorage of equipment in the area appear to be free of potentially adverse seismic conditions (if visible without necessarily opening cabinets)?

Observed a PVC west of the RWST Purification Pump that is secured to the Unistrut with a zip tie. The PVC comes out of the west wall and penetrates PA 119 duct in the overhead (see attached photos). The unsupported length from the wall to the duct is approximately 12 ft. This is documented in CR-IP3-2012-03583.

LB-15 evaluates this condition.

2. Does anchorage of equipment in the area appear to be free of significant degraded conditions?

Yes, anchorage of equipment in the area appears to be free of significant degraded conditions.

YDI NEI UD- N/A-1 Y[J NDI UD N/AD-3. Based on a visual inspection from the floor, do the cable/conduit raceways and HVAC ducting appear to be free of potentially adverse seismic conditions (e.g., condition of supports is adequate and fill conditions of cable trays appear to be inside acceptable limits)?YE- NEI u[D N/ADýYes, based on a visual inspection from the floor, the cable/conduit raceways and HVAC ducting appears to be free of potentially adverse seismic conditions.

If the room in which the SWEL item is located is very, large (e.g., Turbine Hall), the area selected should be described.

This selected area should be based on judgment, e.g., on the order of about 35 feet from the SWEL item.EN-DC-168 REV 0 Engineering Report No. IP-RPT-12-00039, Rev. 0, Page D-149 of 192 ATTACHMENT 9.7 AREA WALK-BY CHECKLIST Sheet 2 of 4 1P3 Status: Y[J NEI UD-I Area Walk-By Checklist (AWC) AWC-033 Location:

Bldg. PAB Floor El. 41'-0" Room, Area'SWEL Components:

SWEL2-O01 4. Does it appear that the area is free of potentially adverse seismic Y[] NDI U[l N/AEi spatial interactions with other equipment in the area (e.g., ceiling tiles and lighting)?

Yes, it appears that the area is free of potentially adverse seismic spatial interactions with other equipment in the area.5. Does it appear that the area is free of potentially adverse seismic interactions that could cause flooding or spray in the area?Yes, it appears that the area is free of potentially adverse seismic interactions that could cause flooding or spray in the area.Y[I NEI UD- N/AD-6. Does it appear that the area is free of potentially adverse seismic interactions that could cause a fire in the area?Yes, it appears that the area is free of potentially adverse seismic interactions that could cause a fire in the area.YZ NEI UD- N/A--7. Does it appear that the area is free of potentially adverse seismic interactions associated with housekeeping practices, storage of portable equipment, and temporary installations (e.g., scaffolding, lead shielding)?

Observed a compressed air tank cap resting on the compressed air tank support (gas bottle rack) located on the south wall near RWST Purification Pump. During a seismic event, the cap may act as a missile and strike nearby equipment.

This is documented in CR-IP3-2012-03501.YDI N[ uDl N/AD-EN-DC-168 REV 0 Engineering Report No. IP-RPT-12-00039, Rev. 0, Page D-150 of 192 ATTACHMENT 9.7 AREA WALK-BY CHECKLIST Sheet 3 of 4 IP3 Status: YIZ ND-- uLD Area Walk-By Checklist (AWC) AWC-033 Location:

Bldg. PAB Floor El. 41'-0" Room, Area 1 SWEL Components:

SWEL2-001 8. Have you looked for and found no other seismic conditions that could Y[ N[D UI--adversely affect the safety functions of the equipment in the area?Yes, we have looked for and found no other seismic conditions that could adversely affect the safety functions of the equipment in the area.Comments (Additional pages may be added as necessary)

Observed a clock mounted on the north wall near the RWST Purification Pump and the Monitor Tank Pumps that is well secured. SWES judged the clock to have no adverse seismic interaction.

Reference:

LB-15 Evaluated by: Maggie Farah Date: 10/22/12 Kai Lo Ic 6 10/22/12 EN-DC-168 REV 0 Engineering Report No IP-RPT-12-00039 Rev 0. Page D-151 of 192 ATTACHMENT 9.7 AREA WALK-BY CHECKLIST Sheet 4 of 4 IP3 Status: YEA NEn UL Area Walk-By Checklist (AWC) AWC-033 Location:

Bldg. PAB Floor El. 41'-0" Room, Area 1 SWEL Components:

SWEL2-001 Photographs-i-F Note: PVC penetrates duct i i Note: Loose cap behind the compressed air Note: bottles.EN-DC-168 REV 0 Engineering Report No. IP-RPT-12-00039, Rev. 0, Page D-152 of 192 ATTACHMENT 9.7 AREA WALK-BY CHECKLIST Sheet I of 3 IP3 Status: YDI NDI Area Walk-By Checklist (AWC) AWC-034 Location:

Bldg. PA Floor El. 73'-0" Room,Area 1 SWEL Components:

SWELl -084, 097 Instructions for Completing Checklist This checklist may be used to document the results of the Area Walk-By near one or more SWEL items. The space below each of the following questions may be used to record the results of judgments and findings.Additional space is provided at the end of this checklist for documenting other comments.1. Does anchorage of equipment in the area appear to be free of potentially adverse seismic conditions (if visible without necessarily opening cabinets)?

Yes, anchorage of equipment in the area appears to be free of potentially adverse seismic conditions.

2. Does anchorage of equipment in the area appear to be free of significant degraded conditions?

Yes, anchorage of equipment in the area appears to be free of significant degraded conditions.

3. Based on a visual inspection from the floor, do the cable/conduit raceways and HVAC ducting appear to be free of potentially adverse seismic conditions (e.g., condition of supports is adequate and fill conditions of cable trays appear to be inside acceptable limits)?Yes, based on a visual inspection from the floor, the cable/conduit raceways and HVAC ducting appears to be free of potentially adverse seismic conditions.
4. Does it appear that the area is free of potentially adverse seismic spatial interactions with other equipment in the area (e.g., ceiling tiles and lighting)?

Yes, it appears that the area is free of potentially adverse seismic spatial interactions with other equipment in the area.5. Does it appear that the area is free of potentially adverse seismic interactions that could cause flooding or spray in the area?YX NDI UD- N/AD Y[Z NDI UD N/A-YN ND] uD- N/AD Y[ NDI UD- N/A--YIZ NDI uD- N/AD-Yes, it appears that the area is free of potentially adverse seismic interactions that could cause flooding or spray in the area.If the room in which the SWEL item is located is very large (e.g., Turbine Hall), the area selected should be described.

This selected area should be based on judgmnent, e.g., on the order of about 35 feet from the SWEL item.EN-DC-168 REV 0 Engineering Report No. IP-RPT-12-00039, Rev 0, Page 0-153 of 192 ATTACHMENT 9.7 AREA WALK-BY CHECKLIST Sheet 2 of 3 IP3 Status: YD- NDI u-Area Walk-By Checklist (AWC) AWC-034 Location:

Bldg. PA Floor El. 73'-0" Room, Area 1 SWEL Components:

SWELl -084, 097 6. Does it appear that the area is free of potentially adverse seismic Y[Z N[D UD- N/AD-interactions that could cause a fire in the area?Yes, it appears that the area is free of potentially adverse seismic interactions that could cause a fire in the area.7. Does it appear that the area is free of potentially adverse seismic YE NDI UD N/AD-interactions associated with housekeeping practices, storage of portable equipment, and temporary installations (e.g., scaffolding, lead shielding)?

Yes, it appears that the area is free of potentially adverse seismic interactions associated with housekeeping practices, storage of portable equipment, and temporary installations.

8. Have you looked for and found no other seismic conditions that could YZ NDI UD7 adversely affect the safety functions of the equipment in the area?Yes, we have looked for and found no other seismic conditions that could adversely affect the safety functions of the equipment in the area.Comments (Additional pages may be added as necessary)

Reference:

IP3 S WEL 1-029 Date: 10/22/12 Evaluated by: Stephen Yuan__ -__Date: 10/22/12 Paul Huebsch EN-DC-168 REV 0 Engineering Report No. IP-RPT-12-00039, Rev. 0, Page D-154 of 192 ATTACHMENT 9.7 AREA WALK-BY CHECKLIST Sheet 3 of 3 IP3 Status: YO- NEI U[Area Walk-By Checklist (AWC) AWC-034 Location:

Bldg. PA Floor El. 73'-0" Room, Area'SWEL Components:

SWELl -084, 097 Photographs Note: no photos attached Note: EN-DC-168 REV 0 Engineering Report No. IP-RPT-12-00039, Rev. 0, Page D-155 of 192 ATTACHMENT 9.7 AREA WALK-BY CHECKLIST Sheet I of 4 IP3 Status: Y[ N7 UL-I Area Walk-By Checklist (AWC) AWC-035 Location:

Bldg. PA Floor El. 41'-0" Room, Area'SWEL Components:

SWELl -045 Instructions for Completing Checklist This checklist may be used to document the results of the Area Walk-By near one or more SWEL items. The space below each of the following questions may be used to record the results of judgments and findings.Additional space is provided at the end of this checklist for documenting other comments.1. Does anchorage of equipment in the area appear to be free of potentially adverse seismic conditions (if visible without necessarily opening cabinets)?

Yes anchorage of equipment in the area appears to be free of potentially adverse seismic conditions.

Y] N[D] U[-- N/A[-]2. Does anchorage of equipment in the area appear to be free of significant degraded conditions?

Yes anchorage of equipment in the area appears to be free of significant degraded conditions.

Y[9 ND-- UDI N/A--3. Based on a visual inspection from the floor, do the cable/conduit raceways and HVAC ducting appear to be free of potentially adverse seismic conditions (e.g., condition of supports is adequate and fill conditions of cable trays appear to be inside acceptable limits)?Y[ ND] UD- N/AFI Yes based on a visual inspection from the floor, the cable/conduit raceways and HVAC ducting appears to be free of potentially adverse seismic conditions.

' If the room in which the SWEL item is located is very large (e.g., Turbine Hall), the area selected should be described.

This selected area should be based on judgment, e.g., on the order of about 35 feet fr-om ithe SWEL item.EN-DC-168 REV 0 Engineering Report No. IP-RPT-12-00039, Rev. 0, Page D-156 of 192 ATTACHMENT 9.7 AREA WALK-BY CHECKLIST Sheet 2 of 4 IP3 Status: Y[R NEI Ut--Area Walk-By Checklist (AWC) AWC-035 Location:

Bldg. PA Floor El. 41'-0" Room, Area 1 SWEL Components:

SWELl -045 4. Does it appear that the area is free of potentially adverse seismic Y[ NDI UD-- N/AD spatial interactions with other equipment in the area (e.g., ceiling tiles and lighting)?

Yes, it appears that the area is free of potentially adverse seismic spatial interactions with other equipment in the area.5. Does it appear that the area is free of potentially adverse seismic interactions that could cause flooding or spray in the area?Yes, it appears that the area is free of potentially adverse seismic interactions that could cause flooding or spray in the area.There is a considerable amount of water on the floor indicating potential leakage from piping in the area. CR-IP3-2012-3527 has been written to remedy this condition.

6. Does it appear that the area is free of potentially adverse seismic interactions that could cause a fire in the area?Yes, it appears that the area is free of potentially adverse seismic interactions that could cause a fire in the area.YE[ NDI U-- N/AD--YO NDI U[- N/AD-7. Does it appear that the area is free of potentially adverse seismic interactions associated with housekeeping practices, storage of portable equipment, and temporary installations (e.g., scaffolding, lead shielding)?

Several lights are out and need to be replaced.

The florescent tube needs to be restrained.

CR-IP3-2012-03661has been written to remedy this condition.

YN NDI uD- N/AD-EN-DC-168 REV 0 Engineering Report No. IP-RPT-12-00039, Rev. 0, Page D-157 of 192 ATTACHMENT 9.7 AREA WALK-BY CHECKLIST Sheet 3 of 4 IP3 Status: Y-- N7 U7 Area Walk-By Checklist (AWC) AWC-035 Location:

Bldg. PA FloorEl. 41-0" Room, Area 1 SWEL Components:

SWELl -045 8. Have you looked for and found no other seismic conditions that could Y[E NEil U il adversely affect the safety functions of the equipment in the area?Yes we have looked for and found no other seismic conditions that could adversely affect the safety functions of the equipment in the area.Comments (Additional pages may be added as necessary)

Evaluated by: Stephen Yuan Date: 10/22/2012 2 (J~7) 4~~r (I-0o .l 14, ,ho, " h Date: 10/22/2012 EN-DC-168 REV 0 Engineering Report No IP-RPT-12-00039.

Rev 0, Page D-158 of 192 ATTACHMENT 9.7 AREA WALK-BY CHECKLIST Sheet 4 of 4 IP3 Status: YW] NFI UFD Area Walk-By Checklist (AWC) AWC-035 Location:

Bldg. PA Floor El. 41'-0" Room, Area'SWEL Components:

SWELl -045 Photographs Note: There is a considerable amount of water on Note: the floor indicating potential leakage from piping in the area.EN-DC-168 REV 0 Engineering Report No. IP-RPT-12-00039, Rev. 0, Page D-159 of 192 ATTACHMENT 9.7 AREA WALK-BY CHECKLIST Sheet I of 5 1P3 Status: Y[1 ND UE[Area Walk-By Checklist (AWC) AWC-036 Location:

Bldg. IS Floor El. 15ý-0" Room, Area 1 SWEL Components:

SWELl -001. 002 Instructions for Completing Checklist This checklist may be used to document the results of the Area Walk-By near one or more SWEL items. The space below each of the following questions may be used to record the results of judgments and findings.Additional space is provided at the end of this checklist for documenting other comments.1. Does anchorage of equipment in the area appear to be free of potentially adverse seismic conditions (if visible without necessarily opening cabinets)?

Nearby Unistruts for panels and stanchions for pipe supports show varying signs of advanced corrosion.

CR-IP3-2012-03633 has been written to remedy the condition for the stanchions.

EC-38453 was generated to repair DPIC-1 111 and DPIC-1 113 thru 1116 racks. EC-28998 was generated for the corroded IA supports.2. Does anchorage of equipment in the area appear to be free of significant degraded conditions?

Nearby Unistruts for panels and stanchions for pipe supports show varying signs of advanced corrosion.

CR-IP3-2012-03633 has been written to remedy this condition.

EC-38453 was generated for the DPIC racks. EC-28998 was generated for the IA supports.3. Based on a visual inspection from the floor, do the cable/conduit raceways and HVAC ducting appear to be free of potentially adverse seismic conditions (e.g., condition of supports is adequate and fill conditions of cable trays appear to be inside acceptable limits)?YDI NM UD N/AD-YDI NZ UD- N/AD-YE- ND U[ N/AD-]Yes based on a visual inspection from the floor, the cable/conduit raceways and HVAC ducting appears to be free of potentially adverse seismic conditions.

If the room in which the SWEL item is located is very large (e.g., Turbine Hall), the area selected should be described.

This selected area should be based on judgment, e.g., on the order of about 35 feet from the SWEL item.EN-DC-1 68 REV 0 Engineering Report No. IP-RPT-12-00039, Rev. 0, Page D-160 of 192 ATTACHMENT 9.7 AREA WALK-BY CHECKLIST Sheet 2 of 5 IP3 Status: Y[ ND UI]Area Walk-By Checklist (AWC) AWC-036 Location:

Bldg. IS Floor El. 15'-0" Room, Area'SWEL Components:

SWELl-001.

002 4. Does it appear that the area is free of potentially adverse seismic YE NE-l UD N/AD spatial interactions with other equipment in the area (e.g., ceiling tiles and lighting)?

The area has bar grating at the ceiling level and it is determined that the grating is well secured to the support steel and not subject to displacement.

5. Does it appear that the area is free of potentially adverse seismic interactions that could cause flooding or spray in the area?Yes, it appears that the area is free of potentially adverse seismic interactions that could cause flooding or spray in the area.YU ND uD N/AD1 6. Does it appear that the area is free of potentially adverse seismic interactions that could cause a fire in the area?Yes, it appears that the area is free of potentially adverse seismic interactions that could cause a fire in the area.NDI uD N/ADl 7. Does it appear that the area is free of potentially adverse seismic interactions associated with housekeeping practices, storage of portable equipment, and temporary installations (e.g., scaffolding, lead shielding)?

Yes it appears that the area is free of potentially adverse seismic interactions associated with housekeeping practices, storage of portable equipment, and temporary installations.

Y[ NDI uD N/AD EN-DC-168 REV 0 Engineering Report No. IP-RPT-12-00039, Rev. 0, Page D-161 of 192 ATTACHMENT 9.7 AREA WALK-BY CHECKLIST Sheet 3 of 5 1P3 Status: YE NEI UDI Area Walk-By Checklist (AWC) AWC-036 Location:

Bldg. IS Floor El. 15'-0" Room, Area'SWEL Components:

SWELl -001, 002 8. Have you looked for and found no other seismic conditions that could YEJ NEI Ui adversely affect the safety functions of the equipment in the area?Yes we have looked for and found no other seismic conditions that could adversely affect the safety functions of the equipment in the area.Comments (Additional pages may be added as necessary)

Evaluated by: Stephen Yuan Date: 10/23/2012 Date: 10/23/2012 Paul Huebsch EN-DC-168 REV 0 Engineering Report No IP-RPT-12-00039, Rev 0, Page D-162 of 192 ATTACHMENT 9.7 AREA WALK-BY CHECKLIST Sheet 4 of 5 IP3 Status: YE[ NE] UD-]Area Walk-By Checklist (AWC) AWC-036 Location:

Bldg. IS Floor El. 15'-0" Room, Area'SWEL Components:

SWELl -001, 002 Photographs Note: Anchor bolt for strainer some corrosion of base angle.Note: Scaffol tag.Corrosion at the base of a Unistrut column I I EN-DC-168 REV 0 Engineering Report No IP-RPT-12-00039, Rev 0, Page D-163 of 192 ATTACHMENT 9.7 AREA WALK-BY CHECKLIST Sheet 5 of 5 IP3 Status: YFý NEI UEl Area Walk-By Checklist (AWC) AWC-036 Location:

Bldg. IS Floor El. 15'-0" Room, Area 1 SWEL Comoonents:

SWELl -001. 002)te: Unistrut column which is beginning to tilt Note: pe support stancnion snowing Note: rating torming me ceiling, or e room is considerable corrosion well secured to the support steel EN-DC-168 REV 0 Engineering Report No. IP-RPT-12-00039, Rev. 0, Page D-164 of 192 ATTACHMENT 9.7 AREA WALK-BY CHECKLIST Sheet I of 3 Status: YEZ NDI U-]Area Walk-By Checklist (AWC) AWC-037 Location:

Bldg. DG Floor El. 38-6" Room, Area'SWEL Components:

SWELl -032 Instructions for Completing Checklist This checklist may be used to document the results of the Area Walk-By near one or more SWEL items. The space below each of the following questions may be used to record the results of judgments and findings.Additional space is provided at the end of this checklist for documenting other comments.1. Does anchorage of equipment in the area appear to be free of potentially adverse seismic conditions (if visible without necessarily opening cabinets)?

Yes anchorage of equipment in the area appears to be free of potentially adverse seismic conditions.

2. Does anchorage of equipment in the area appear to be free of significant degraded conditions?

Yes anchorage of equipment in the area appears to be free of significant degraded conditions.

3. Based on a visual inspection from the floor, do the cable/conduit raceways and HVAC ducting appear to be free of potentially adverse seismic conditions (e.g., condition of supports is adequate and fill conditions of cable trays appear to be inside acceptable limits)?Pump is in a pit with no HVAC or conduit raceways above.4. Does it appear that the area is free of potentially adverse seismic spatial interactions with other equipment in the area (e.g., ceiling tiles and lighting)?

Yes, it appears that the area is free of potentially adverse seismic spatial interactions with other equipment in the area..5. Does it appear that the area is free of potentially adverse seismic interactions that could cause flooding or spray in the area?YZ NE] UD- N/ADI YEZ NDI UiD N/ADl YDI NDI U-- N/AZ YE NDI UED N/AD-YE NDI UDi N/AD1 Yes, it appears that the area is free of potentially adverse seismic interactions that could cause flooding or spray in the area.If the room in which the SWEL item is located is very large (e.g.. Turbine Hall), the area selected should be described.

This selected area should be based on judgment, e.g., on the order of about 35 feet fr'om the SWEL item.EN-DC-168 REV 0 Engineering Report No. IP-RPT-12-00039, Rev. 0, Page D-165 of 192 ATTACHMENT 9.7 AREA WALK-BY CHECKLIST Sheet 2 of 3 Status: YE NDI UD-Area Walk-By Checklist (AWC) AWC-037 Location:

Bldg. DG Floor El. 38'-6" Room, Area'SWEL Components:

SWELI-032 6. Does it appear that the area is free of potentially adverse seismic Y[ N[D- uD- N/ADI interactions that could cause a fire in the area?Yes, it appears that the area is free of potentially adverse seismic interactions that could cause a fire in the area.7. Does it appear that the area is free of potentially adverse seismic YN NDI UD- N/AD-interactions associated with housekeeping practices, storage of portable equipment, and temporary installations (e.g., scaffolding, lead shielding)?

Yes it appears that the area is free of potentially adverse seismic interactions associated with housekeeping practices, storage of portable equipment, and temporary installations.

8. Have you looked for and found no other seismic conditions that could YN NDI UD adversely affect the safety functions of the equipment in the area?Yes we have looked for and found no other seismic conditions that could adversely affect the safety functions of the equipment in the area.Comments (Additional pages may be added as necessary)

Evaluated by: Stephen Yuan Date: 10/22/2012 lK IVt 12 0 j____________________

Date: 10/22/2012 Paul Huebsch EN-DC-168 REV 0 Engineering Report No IP-RPT-12-00039, Rev 0 Page D-166 of 192 ATTACHMENT 9.7 AREA WALK-BY CHECKLIST Sheet 3 of 3 Status: YZ NFI UFi Area Walk-By Checklist (AWC) AWC-037 Location:

Bldg. DG Floor El. 38-6" Room, Area'SWEL Components:

SWELl -032 Photographs Note: F. O. Transfer Pump Note: Another view of the pump.EN-DC-168 REV 0 Engineering Report No. IP-RPT-12-00039.

Rev 0. Page D-167 of 192 ATTACHMENT 9.7 AREA WALK-BY CHECKLIST Sheet I of 4 Status: YE] ND UD Area Walk-By Checklist (AWC) AWC-038 Location:

Bldg. PP Floor El. 41'-0" Room, Area'SWEL Components:

1-036, 037 Instructions for Completing Checklist This checklist may be used to document the results of the Area Walk-By near one or more SWEL items. The space below each of the following questions may be used to record the results of judgments and findings.Additional space is provided at the end of this checklist for documenting other comments.1. Does anchorage of equipment in the area appear to be free of potentially adverse seismic conditions (if visible without necessarily opening cabinets)?

Yes, anchorage of equipment in the area appears to be free of potentially adverse seismic conditions.

YE] NEI UD- N/AD-I 2. Does anchorage of equipment in the area appear to be free of significant degraded conditions?

Yes anchorage of equipment in the area appears to be free of significant degraded conditions.

YE] NDl U-- N/AD-3. Based on a visual inspection from the floor, do the cable/conduit raceways and HVAC ducting appear to be free of potentially adverse seismic conditions (e.g., condition of supports is adequate and fill conditions of cable trays appear to be inside acceptable limits)?YE] NDI U[] N/A-Yes based on a visual inspection from the floor, the cable/conduit raceways and HVAC ducting appears to be free of potentially adverse seismic conditions.

If the room in which the SWEL item is located is very large (e.g., Turbine Hall), the area selected should be described.

This selected area should be based on judgment, e.g., oil the order of about 35 feet from the SWEL item.EN-DC-168 REV 0 Engineering Report No. IP-RPT-12-00039, Rev. 0, Page D-168 of 192 ATTACHMENT 9.7 AREA WALK-BY CHECKLIST Sheet 2 of 4 Status: YN NEI U[i Area Walk-By Checklist (AWC) AWC-038 Location:

Bldg. PP Floor El. 41'-0" Room, Area 1 SWEL Components:

1-036, 037 4. Does it appear that the area is free of potentially adverse seismic spatial interactions with other equipment in the area (e.g., ceiling tiles and lighting)?

Yes, it appears that the area is free of potentially adverse seismic spatial interactions with other equipment in the area..YEZ NEI UD1 N/AD 5. Does it appear that the area is free of potentially adverse seismic interactions that could cause flooding or spray in the area?Yes, it appears that the area is free of potentially adverse seismic interactions that could cause flooding or spray in the area.Y[ NEI U-- N/ADI 6. Does it appear that the area is free of potentially adverse seismic interactions that could cause a fire in the area?Yes, it appears that the area is free of potentially adverse seismic interactions that could cause a fire in the area.YOz NDI u[- N/AD 7. Does it appear that the area is free of potentially adverse seismic interactions associated with housekeeping practices, storage of portable equipment, and temporary installations (e.g., scaffolding, lead shielding)?

Yes it appears that the area is free of potentially adverse seismic interactions associated with housekeeping practices, storage of portable equipment, and temporary installations.

Y[ NDI ur N/ADI EN-DC-168 REV 0 Engineering Report No. IP-RPT-12-00039, Rev. 0, Page D-169 of 192 ATTACHMENT 9.7 AREA WALK-BY CHECKLIST Sheet 3 of 4 Status: YE NOI U[E]Area Walk-By Checklist (AWC) AWC-038 Location:

Bldg. PP Floor El. 41'-0" Room, Area 1 SWEL Components:

1-036, 037 8. Have you looked for and found no other seismic conditions that could Y " NEI U--adversely affect the safety functions of the equipment in the area?Yes we have looked for and found no other seismic conditions that could adversely affect the safety functions of the equipment in the area.Comments (Additional pages may be added as necessary)

Evaluated by: Stephe Yuan Date: 10/22/2012 Date: 10/22/2012 Paul Huebsch EN-DC-168 REV 0 Engineering Report No IP-RPT-12-00039 Rev 0 Page D-170 of 192 ATTACHMENT 9.7 AREA WALK-BY CHECKLIST Sheet 4 of 4 Status: YW Nn UEL Area Walk-By Checklist (AWC) AWC-038 Location:

Bldg. PP Floor El. 41'-0" Room, Area 1 SWEL Components:

1-036, 037 Photographs EN-DC-168 REV 0 Engineering Report No. IP-RPT-12-00039, Rev. 0, Page D-171 of 192 ATTACHMENT 9.7 AREA WALK-BY CHECKLIST Sheet I of 3 IP3 Status: YN1 NDl UD-Area Walk-By Checklist (AWC) AWC-039 Location:

Bldg. FB Floor El. 72'-0" Room, Area'SWEL Components:

SWELl -046 Instructions for Completing Checklist This checklist may be used to document the results of the Area Walk-By near one or more SWEL items. The space below each of the following questions may be used to record the results of judgments and findings.Additional space is provided at the end of this checklist for documenting other comments.1. Does anchorage of equipment in the area appear to be free of YE NE-i UI- N/AD--potentially adverse seismic conditions (if visible without necessarily opening cabinets)?

Yes, anchorage of equipment in the area appears to be free of potentially adverse seismic conditions.

2. Does anchorage of equipment in the area appear to be free of significant degraded conditions?

Yes, anchorage of equipment in the area appears to be free of significant degraded conditions.

3. Based on a visual inspection from the floor, do the cable/conduit raceways and HVAC ducting appear to be free of potentially adverse seismic conditions (e.g., condition of supports is adequate and fill conditions of cable trays appear to be inside acceptable limits)?Yes, based on a visual inspection from the floor, the cable/conduit raceways and HVAC ducting appears to be free of potentially adverse seismic conditions.
4. Does it appear that the area is free of potentially adverse seismic spatial interactions with other equipment in the area (e.g., ceiling tiles and lighting)?

Yes, it appears that the area is free of potentially adverse seismic spatial interactions with other equipment in the area.5. Does it appear that the area is free of potentially adverse seismic interactions that could cause flooding or spray in the area?YZ ND] UD- N/A--YlM NDI UD- N/AD1 YM NDI Uf1 N/ADl Y[ ND UD- N/AD-Yes, it appears that the area is free of potentially adverse seismic interactions that could cause flooding or spray in the area.If the room in which the SWEL item is located is ver)' large (e.g., Turbine Hall), the area selected should be described.

This selected area should be based on judgment, e.g., on the order of about 35 feet from the SWEL item.EN-DC-168 REV 0 Engineering Report No. IP-RPT-12-00039, Rev. 0, Page D-172 of 192 ATTACHMENT 9.7 AREA WALK-BY CHECKLIST Sheet 2 of 3 IP3 Status: YE[ NDI UD Area Walk-By Checklist (AWC) AWC-039 Location:

Bldg. FB Floor El. 72'-0" Room, Area'SWEL Components:

SWELl -046 6. Does it appear that the area is free of potentially adverse seismic YZ NEI UL N/ADl interactions that could cause a fire in the area?Yes, it appears that the area is free of potentially adverse seismic interactions that could cause a fire in the area.7. Does it appear that the area is free of potentially adverse seismic YE NDI UD N/AD interactions associated with housekeeping practices, storage of portable equipment, and temporary installations (e.g., scaffolding, lead shielding)?

Yes, it appears that the area is free of potentially adverse seismic interactions associated with housekeeping practices, storage of portable equipment, and temporary installations.

8. Have you looked for and found no other seismic conditions that could YE NDI uD adversely affect the safety functions of the equipment in the area?Yes, we have looked for and found no other seismic conditions that could adversely affect the safety functions of the equipment in the area.Comments (Additional pages may be added as necessary)

Ceiling light bulb at the southeast comer of the room needs to be replaced.

This is documented in CR-IP3-2012-03497.

J5 ýCLA Evaluated by: Maggie Farah Date: 10/24/12 Kai Lo Ic hII 10/24/12 EN-DC-168 REV 0 Engineering Report No. IP-RPT-12-00039, Rev. 0, Page D-173 of 192 ATTACHMENT 9.7 AREA WALK-BY CHECKLIST Sheet 3 of 3 IP3 Status: YN N-- UD-]Area Walk-By Checklist (AWC) AWC-039 Location:

Bldg. FB Floor El. 72'-0" Room, Area'SWEL Components:

SWELl -046 Photographs Note: no photos attached.

Note: EN-DC-168 REV 0 Engineering Report No. IP-RPT-12-00039, Rev. 0, Page D-174 of 192 ATTACHMENT 9.7 AREA WALK-BY CHECKLIST Sheet I of 5 IP3 Status: Y[ NI] UD-q Area Walk-By Checklist (AWC) AWC-040 Location:

Bldg. ET Floor El. 46'-0" Room, Area 1 FAN ROOM SWEL Components:

SWELl -047 Instructions for Completing Checklist This checklist may be used to document the results of the Area Walk-By near one or more SWEL items. The space below each of the following questions may be used to record the results of judgments and findings.Additional space is provided at the end of this checklist for documenting other comments.1. Does anchorage of equipment in the area appear to be free of potentially adverse seismic conditions (if visible without necessarily opening cabinets)?

Yes, anchorage of equipment in the area appears to be free of potentially adverse seismic conditions.

2. Does anchorage of equipment in the area appear to be free of significant degraded conditions?

Yes, anchorage of equipment in the area appears to be free of significant degraded conditions.

YEE NI uLID N/AD YE-- NEI UD N/A-3. Based on a visual inspection from the floor, do the cable/conduit raceways and HVAC ducting appear to be free of potentially adverse seismic conditions (e.g., condition of supports is adequate and fill conditions of cable trays appear to be inside acceptable limits)?Overhead duct is well supported near the south wall. Therefore, based on a visual inspection from the floor, the cable/conduit raceways and HVAC ducting appears to be free of potentially adverse seismic conditions.

4. Does it appear that the area is free of potentially adverse seismic spatial interactions with other equipment in the area (e.g., ceiling tiles and lighting)?

YLZ NEI uD- N/AD YE NEI UD- N/AD-Yes, it appears that the area is free of potentially adverse seismic spatial interactions with other equipment in the area.If the room in which the SWEL item is located is ver'y large (e.g., Turbine Hall), the area selected should be described.

This selected area should be based on judgnent, e.g., on the order of about 35 feet firom the SWEL item.EN-DC-168 REV 0 Engineering Report No. IP-RPT-12-00039, Rev. 0, Page D-175 of 192 ATTACHMENT 9.7 AREA WALK-BY CHECKLIST Sheet 2 of 5 IP3 Status: YZ NEl u7-Area Walk-By Checklist (AWC) AWC-040 Location:

Bldg. ET Floor El. 46'-0" Room, Area' FAN ROOM SWEL Components:

SWELl -047 5. Does it appear that the area is free of potentially adverse seismic interactions that could cause flooding or spray in the area?Yes, it appears that the area is free of potentially adverse seismic interactions that could cause flooding or spray in the area.6. Does it appear that the area is free of potentially adverse seismic interactions that could cause a fire in the area?Yes, it appears that the area is free of potentially adverse seismic interactions that could cause a fire in the area.7. Does it appear that the area is free of potentially adverse seismic interactions associated with housekeeping practices, storage of portable equipment, and temporary installations (e.g., scaffolding, lead shielding)?

Observed two unrestrained ladders on the floor, one by the north wall and the other by the south wall (see attached photos). During a seismic event the ladders may act as missile and strike the fans.Observed a piping plug that is resting on the floor near the uncover pipe (see attached photo). During a seismic event the plug may act as a missile and strike the Exhaust Fans. In addition, debris may enter the uncovered piping.Observed an unrestrained broom stick on the north wall. During a seismic event the broom stick may act as a missile and strike the fans.Observed a wheeled chair in the southeast comer of the room by the door During a seismic event the chair may dislodge and strike the fans.The above items are addressed in CR-IP3-2012-03498.

YO NEI U0 N/A--YO ND- UDl N/AD YEI NO U-- N/AD-EN-DC-168 REV 0 Engineering Report No. IP-RPT-12-00039, Rev. 0, Page D-176 of 192 ATTACHMENT 9.7 AREA WALK-BY CHECKLIST Sheet 3 of 5 1P3 Status: YEZ ND U[-1 Area Walk-By Checklist (AWC) AWC-040 Location:

Bldg. ET Floor El. 46'-0" Room, Area 1 FAN ROOM SWEL Components:

SWELl -047 8. Have you looked for and found no other seismic conditions that could YZ NEI uD--adversely affect the safety functions of the equipment in the area?Yes we have looked for and found no other seismic conditions that could adversely affect the safety functions of the equipment in the area.Comments (Additional pages may be added as necessary)

Observed broken glass in the east comer of the room.Observed bolts and nuts on the electrical box connected to the GAI-Tronics on the east wall by the door.Flashing along the north wall is deteriorated, broken and missing.The above items are addressed in CR-IP3-2012-03498.

Reference:

IP3 SWELl-047 Evaluated by: Maggie Farah Date: 1024/12 j4iý_Kai Loi/c 10/24/12 EN-DC-168 REV 0 Engineering Report No IP-RPT-12-00039 Rev 0 Page D-177 of 192 ATTACHMENT 9.7 AREA WALK-BY CHECKLIST Sheet 4 of 5 IP3 Status: Y[W ND ULII Area Walk-By Checklist (AWC) AWC-040 Location:

Bldg. ET Floor El. 46'-0" Room, Area' FAN ROOM SWEL Components:

SWELl -047 Photographs Note: unrestrained ladder by the north wall. Note: unrestrained ladder by the door at the south comer of the room.Note: unrestrained broom stick: Loose plug ano unpiuggeo piping.EN-DC-168 REV 0 Engineering Report No IP-RPT-12-00039 Rev 0 Page D-178 of 192 ATTACHMENT 9.7 AREA WALK-BY CHECKLIST Sheet 5 of 5 1P3 Status: YEI NFI UJE Area Walk-By Checklist (AWC) AWC-040 Location:

Bldg. ET Floor El. 46'-0" Room, Area 1 FAN ROOM SWEL Components:

SWELl -047 Note: Broken glass in the east comer of the Note: Bolts and nuts on top of electrical box for room. GAI- Tronics.EN-DC-168 REV 0 Engineering Report No. IP-RPT-12-00039, Rev. 0, Page D-179 of 192 ATTACHMENT 9.7 AREA WALK-BY CHECKLIST Sheet I of 5 1P3 Status: YE NEI UD-Area Walk-By Checklist (AWC) AWC-041 Location:

Bldg. FSB Floor El. 41'-0" Room, Area 1 SPENT FUEL PIT PUMP SWEL Components:

SWEL2-002, 003 Instructions for Completing Checklist This checklist may be used to document the results of the Area Walk-By near one or more SWEL items. The space below each of the following questions may be used to record the results of judgments and findings.Additional space is provided at the end of this checklist for documenting other comments.1. Does anchorage of equipment in the area appear to be free of potentially adverse seismic conditions (if visible without necessarily opening cabinets)?

Yes, anchorage of equipment in the area appears to be free of potentially adverse seismic conditions.

2. Does anchorage of equipment in the area appear to be free of significant degraded conditions?

Yes, anchorage of equipment in the area appears to be free of significant degraded conditions.

3. Based on a visual inspection from the floor, do the cable/conduit raceways and HVAC ducting appear to be free of potentially adverse seismic conditions (e.g., condition of supports is adequate and fill conditions of cable trays appear to be inside acceptable limits)?Platfonn and hatch are well supported; therefore, based on a visual inspection from the floor, the cable/conduit raceways and HVAC ducting appears to be free of potentially adverse seismic conditions.

YE NO UD- N/A--YrZ ND U-D N/A--YF] NEI UD- N/A[--4. Does it appear that the area is free of potentially adverse seismic spatial interactions with other equipment in the area (e.g., ceiling tiles and lighting)?

YZ NDI UD- N/AD-Yes, it appears that the area is free of potentially adverse seismic spatial interactions with other equipment in the area.If the room in which the SWEL item is located is very large (e.g., Turbine Hall), the area selected should be described.

This selected area should be based on judgment, e.g., on the order of about 35 feet firom the SWEL item.EN-DC-168 REV 0 Engineering Report No. IP-RPT-12-00039, Rev. 0, Page D-180 of 192 ATTACHMENT 9.7 AREA WALK-BY CHECKLIST Sheet 2 of 5 IP3 Status: YN] N-I U-I Area Walk-By Checklist (AWC) AWC-041 Location:

Bldg. FSB Floor El. 41'-0" Room, Area 1 SPENT FUEL PIT PUMP SWEL Components:

SWEL2-002, 003 5. Does it appear that the area is free of potentially adverse seismic interactions that could cause flooding or spray in the area?Yes, it appears that the area is free of potentially adverse seismic interactions that could cause flooding or spray in the area.YIE NEI ULI N/AD 6. Does it appear that the area is free of potentially adverse seismic interactions that could cause a fire in the area?Yes, it appears that the area is free of potentially adverse seismic interactions that could cause a fire in the area.Y[ NEI ULD N/A-I 7. Does it appear that the area is free of potentially adverse seismic interactions associated with housekeeping practices, storage of portable equipment, and temporary installations (e.g., scaffolding, lead shielding)?

Yes, it appears that the area is free of potentially adverse seismic interactions associated with housekeeping practices, storage of portable equipment, and temporary installations.

YE] N[ uiD N/AE]8. Have you looked for and found no other seismic conditions that could YE NDI ULD adversely affect the safety functions of the equipment in the area?Yes, we have looked for and found no other seismic conditions that could adversely affect the safety functions of the equipment in the area.EN-DC-168 REV 0 Engineering Report No. IP-RPT-12-00039, Rev. 0, Page D-181 of 192 ATTACHMENT 9.7 AREA WALK-By CHECKLIST Sheet 3 of 5 IP3 Status: Y7 NR UF-Area Walk-By Checklist (AWC) AWC-041 Location:

Bldg. FSB Floor El. 41'-0" Room, Area 1 SPENT FUEL PIT PUMP SWEL Components:

SWEL2-002, 003 Comments (Additional pages may be added as necessary)

Observed a drain line that does not reach the floor drain at SEPC-32PP.

The drain line stops approximately 1 foot away from the floor drain. This is addressed in CR-IP3-2012-03497.

Observed a bare cable that is attached to a conduit and runs up to a higher elevation (see attached photos).The following observations are housekeeping:

Plastic bottle sitting on a beam (see attached photo), waste bags on the floor (see attached photos) and light bulbs is out. These items are documented in CR-IP3-2012-03497.

References IP3 SWEL2-002 and 2-003 Evaluated by: Stephen Yuan Date: 10/2612 Maggie Farah 10/26/12 EN-DC-168 REV 0 Engineering Report No IP-RPT-12-00039 Rev 0 Page D-182 of 192 ATTACHMENT 9.7 AREA WALK-BY CHECKLIST Sheet 4 of 5 IP3 Status: YE[ NFI UEI Area Walk-By Checklist (AWC) AWC-041 Location:

Bldg. FSB Floor El, 41'-0" Room. Areal SPENT FUEL PIT PUMP SWEL Components:

SWEL2-002, 003 Photographs Note: bottle sitting on a beam Note: waste bad on theflo Note: waste bag on me a conduit EN-DC-168 REV 0 Engineering Report No IP-RPT-12-00039, Rev 0. Page D-183 of 192 ATTACHMENT 9.7 AREA WALK-BY CHECKLIST Sheet 5 of 5 IP3 Status: YFI NEI UD1 Area Walk-By Checklist (AWC) AWC-041 Location:

Bldg. FSB Floor El. 41'-0" Room, Area 1 SPENT FUEL PIT PUMP SWEL Components:

SWEL2-002, 003 Note: bare wire attached to a conduit Note: EN-DC-168 REV 0 Engineering Report No. IP-RPT-12-00039, Rev. 0, Page D-184 of 192 ATTACHMENT 9.7 AREA WALK-BY CHECKLIST Sheet I of 5 IP3 Status: YZ ND1 UD--Area Walk-By Checklist (AWC) AWC-042 Location:

Bldg. FSB Floor El. 55'-0" Room, Area 1 SWEL Components:

SWEL2-004 Instructions for Completing Checklist This checklist may be used to document the results of the Area Walk-By near one or more SWEL items. The space below each of the following questions may be used to record the results of judgments and findings.Additional space is provided at the end of this checklist for documenting other comments.1. Does anchorage of equipment in the area appear to be free of potentially adverse seismic conditions (if visible without necessarily opening cabinets)?

Yes, anchorage of equipment in the area appears to be free of potentially adverse seismic conditions.

2. Does anchorage of equipment in the area appear to be free of significant degraded conditions?

Yes, anchorage of equipment in the area appears to be free of significant degraded conditions.

3. Based on a visual inspection from the floor, do the cable/conduit raceways and HVAC ducting appear to be free of potentially adverse seismic conditions (e.g., condition of supports is adequate and fill conditions of cable trays appear to be inside acceptable limits)?Yes, based on a visual inspection from the floor, the cable/conduit raceways and HVAC ducting appears to be free of potentially adverse seismic conditions.
4. Does it appear that the area is free of potentially adverse seismic spatial interactions with other equipment in the area (e.g., ceiling tiles and lighting)?

YZ NDI UD N/AD YX NEI UD N/A--YZ NO UD N/AD-YD NEI UD N/AD-Fluorescent light bulbs above the heat Spent Fuel Pit Heat Exchanger are not tied to the fixture. During a seismic event, the bulbs may become loose and strike the heat exchanger gages. This is documented in CR-IP3-2012-03497.

I If the room in which the SWEL item is located is very large (e.g., Turbine Hall), the area selected should be described.

This selected area should be based on judgment, e.g., on the order of about 35 feet from the SWEL item.EN-DC-168 REV 0 Engineering Report No. IP-RPT-12-00039, Rev. 0, Page D-185 of 192 ATTACHMENT 9.7 AREA WALK-BY CHECKLIST Sheet 2 of 5 IP3 Status: YEz NEI UD-]Area Walk-By Checklist (AWC) AWC-042 Location:

Bldg. FSB Floor El. 55'-0' Room, Area 1 SWEL Components:

SWEL2-004 5. Does it appear that the area is free of potentially adverse seismic interactions that could cause flooding or spray in the area?Yes, it appears that the area is free of potentially adverse seismic interactions that could cause flooding or spray in the area.6. Does it appear that the area is free of potentially adverse seismic interactions that could cause a fire in the area?Yes, it appears that the area is free of potentially adverse seismic interactions that could cause a fire in the area.Y0 NEI IUI N/AD YZ NEI U0 N/ADI 7. Does it appear that the area is free of potentially adverse seismic interactions associated with housekeeping practices, storage of portable equipment, and temporary installations (e.g., scaffolding, lead shielding)?

Observed the following: " Unrestrained waste bucket on top of a Boric Acid container east of the heat exchanger (see attached photo)." Unrestrained ladders in a ladder rack (see attached photo)" An unrestrained heater with wheels and a power supplier device on a wheeled cart north of the heat exchanger (see attached photo)." Unrestrained cable and tools on top of the operations equipment cabinet at southwest end of the room (see attached photo).During a seismic event the aforementioned items may act as a missile and strike equipment.

This is documented in CR IP3-2012-03497.

Yll NM N/ADI EN-DC-168 REV 0 Engineering Report No. IP-RPT-12-00039, Rev 0, Page D-186 of 192 ATTACHMENT 9.7 AREA WALK-BY CHECKLIST Sheet 3 of 5 IP3 Status: YE ND-- U--Area Walk-By Checklist (AWC) AWC-042 Location:

Bldg. FSB FloorEl. 55'-0" Room,Area 1 SWEL Components:

SWEL2-004 8. Have you looked for and found no other seismic conditions that could Y[- N[D U-adversely affect the safety functions of the equipment in the area?Yes, we have looked for and found no other seismic conditions that could adversely affect the safety functions of the equipment in the area.Comments (Additional pages may be added as necessary)

Observed several waste bags on the floor near the Sump Pump No. 312 just north of the heat exchanger (see attached photo). This is documented in CR-IP3-2012-03497.

Reference:

SWEL2-004 EF___Date:

10/25/12 Evaluated by: Maqqie Farah KaiLo /c. 10/25/12 EN-DC-168 REV 0 Engineering Report No IP-RPT-12-00039.

Rev 0. Page D-187 of 192 ATTACHMENT 9.7 AREA WALK-BY CHECKLIST Sheet 4 of 5 IP3 Status: YZ NRi- U1 Area Walk-By Checklist (AWC) AWC-042 Location:

Bldg. FSB Floor El. 55'-0" Room, Area_SWEL Components:

SWEL2-004 Photographs Note: An unrestrained heater and power supplier device on a wheeled cart Note: Unrestrained cable and tools on top o operations equipment cabinet EN-DC-168 REV 0 Engineering Report No IP-RPT-12-00039 Rev 0 Page D-188 of 192 ATTACHMENT 9.7 AREA WALK-BY CHECKLIST Sheet 5 of 5 IP3 Status: YEI NI ULID Area Walk-By Checklist (AWC) AWC-042 Location:

Bldg. FSB Floor El. 55'-0'SWEL Components:

SWEL2-004 Room, Area'Note: no photo attached.EN-DC-168 REV 0 Engineering Report No. IP-RPT-12-00039, Rev. 0, Page D-189 of 192 ATTACHMENT 9.7 AREA WALK-By CHECKLIST Sheet I of 4 IP3 Status: Y[ ND UD Area Walk-By Checklist (AWC) AWC-043 Location:

Bldg. FSB Floor El. 95'-0" Room, Area 1 SWEL Components:

SWEL2-005, 006, 007, 008, 009 Instructions for Completing Checklist This checklist may be used to document the results of the Area Walk-By near one or more SWEL items. The space below each of the following questions may be used to record the results of judgments and findings.Additional space is provided at the end of this checklist for documenting other comments.1. Does anchorage of equipment in the area appear to be free of Y[- NDi Ui1 N/AD-potentially adverse seismic conditions (if visible without necessarily opening cabinets)?

Yes, anchorage of equipment in the area appears to be free of potentially adverse seismic conditions.

2. Does anchorage of equipment in the area appear to be free of significant degraded conditions?

Yes, anchorage of equipment in the area appears to be free of significant degraded conditions.

YE NEI UDI N/AD 3. Based on a visual inspection from the floor, do the cable/conduit raceways and HVAC ducting appear to be free of potentially adverse seismic conditions (e.g., condition of supports is adequate and fill conditions of cable trays appear to be inside acceptable limits)?Y[Z ND UD- N/AD-Yes, based on a visual inspection from the floor, the cable/conduit raceways and HVAC ducting appears to be free of potentially adverse seismic conditions.

If the room in which the SWEL item is located is very large (e.g., Turbine Hall), the area selected should be described.

This selected area should be based on judgment, e.g., on the order of about 35 feet from the SWEL item.EN-DC-168 REV 0 Engineering Report No. IP-RPT-12-00039, Rev. 0, Page D-190 of 192 ATTACHMENT 9.7 AREA WALK-BY CHECKLIST Sheet 2 of 4 IP3 Status: Y[ NDI UDýArea Walk-By Checklist (AWC) AWC-043 Location:

Bldg. FSB Floor El. 95'-0" Room, Area'SWEL Components:

SWEL2-005, 006, 007, 008, 009 4. Does it appear that the area is free of potentially adverse seismic YE ND UiEl N/A[iI spatial interactions with other equipment in the area (e.g., ceiling tiles and lighting)?

Yes, it appears that the area is free of potentially adverse seismic spatial interactions with other equipment in the area.5. Does it appear that the area is free of potentially adverse seismic interactions that could cause flooding or spray in the area?Yes, it appears that the area is free of potentially adverse seismic interactions that could cause flooding or spray in the area.YFZ NEI UD N/AD 6. Does it appear that the area is free of potentially adverse seismic interactions that could cause a fire in the area?Yes, it appears that the area is free of potentially adverse seismic interactions that could cause a fire in the area.Y[Z ND U-- N/AE]7. Does it appear that the area is free of potentially adverse seismic interactions associated with housekeeping practices, storage of portable equipment, and temporary installations (e.g., scaffolding, lead shielding)?

Fuel transfer loading is in process. Observed equipment and tools resting on the p/atforms.

This is judged to be acceptable since the equipment and tools are being used as part of fuel transfer process and will likely to be removed after the fuel is transferred.

YE NDI uD N/A[D EN-DC-168 REV 0 Engineering Report No. IP-RPT-12-00039, Rev. 0, Page D-191 of 192 ATTACHMENT 9.7 AREA WALK-By CHECKLIST Sheet 3 of 4 IP3 Status: Y- NFD U-I1 Area Walk-By Checklist (AWC) AWC-043 Location:

Bldg. FSB Floor El. 95'-0" Room, Area 1 SWEL Components:

SWEL2-005, 006, 007, 008, 009 8. Have you looked for and found no other seismic conditions that could YZ NiD U--adversely affect the safety functions of the equipment in the area?Yes, we have looked for and found no other seismic conditions that could adversely affect the safety functions of the equipment in the area.Comments (Additional pages may be added as necessary)

References:

IP3 SWEL2-005, 2-006, 2-007, 2-008, 2-009 Y ýw Evaluated by: Maggie Farah Date: 10/25/12 Kai Lo /C. 6 ' 10125112 EN-DC-168 REV 0 Engineering Report No. IP-RPT-12-00039, Rev. 0, Page D-192 of 192 ATTACHMENT 9.7 AREA WALK-BY CHECKLIST Sheet 4 of 4 IP3 Status: YE N-- Ui Area Walk-By Checklist (AWC) AWC-043 Location:

Bldg. FSB Floor El. 95'-0" Room, Area 1 SWEL Components:

SWEL2-005, 006, 007, 008, 009 Photographs Note: no photos attached.

Note: EN-DC-168 REV 0