ML12291A700

From kanterella
Jump to navigation Jump to search
2012 Dresden Nuclear Power Station Initial License Examination Simulator Quality Checklist ES-301-4
ML12291A700
Person / Time
Site: Dresden  
Issue date: 08/06/2012
From: David Reeser
NRC/RGN-III/DRS/OLB
To:
Exelon Generation Co
Shared Package
ML11354A123 List:
References
Download: ML12291A700 (2)


Text

2012 DRESDEN NUCLEAR POWER STATION INITIAL EXAMINATION PROPOSED EXAM FILES

ES-301 Simulator Scenario Quality Checklist Form ES-301-4 ES-301, Page 25 of 27 Facility: Dresden Date of Exam: S/6I12 Scenario Numbers: 112/3 Operating Test Number: 11-1 (2012-301)

QUALITATIVE ATTRIBUTES Ini~ials a

b*

c#

1.

The initial conditions are realistic, in that some equipment and/or Instrumentation may be out of j' ~ -

service, but it does not cue the operators Into expected events.

2.

The scenarios consist mostly of related events.

~ "i':)

M~

3.

Each event description consists of the point in the scenario when it is to be Initiated the malfunction(s) that are entered to initiate the event nt~

the symptoms/cues that will be visible to the crew the expected operator actions (by shift position) the event termination point (if applicable)

4.

No more than one non-mechanistic failure (e.g., pipe break) is incorporated Into the scenario

t ?

IWtJ without a credible preceding incident such as a seismic event.

5.

The events are valid with regard to physics and thermodynamics.

.~ ?

kt~

6.

Sequencing and timing of events is reasonable, and allows the examination team to obtain

~

".~

complete evaluation results commensurate with the scenario objectives.

t::>

7.

If time compression techniques are used, the scenario summary clearly so indicates.

fJ Operators have sufficient time to carry out expected activities without undue time constraints.

? ctt.,

Cues are given.

S.

The simulator modeling is not altered.

, "'i:>

M~

9.

The scenarios have been validated. Pursuant to 10CFA55.46(d), any open simulator

~

performance deficiencies or deviations from the referenced plant have been evaluated

?

to ensure that functional fidelity Is maintained while running the planned scenarios.

10.

Every operator will be evaluated using at least one new or significantly modified scenario.

1!- ?

-frJ All other scenarios have been altered in accordance with Section 0.5 of ES-301.

11.

AU individual operator competenCies can be evaluated, as verified using Form ES-301-6 (submit the form along with the simulator scenarios).

~ ?

1M"

12.

Each applicant will be significantly involved in the minimum number of transients and events t". i) "'-'t1 specified on Form ES-301-5 (submit the form with the simulator scenarios).

13.

The level of difficulty is appropriate to support licensing decisions for each crew position.

~ 'D "'-if Target Quantitativa Attributes (Per Scenario; See Section D.5.d)

Actual Attributes

1.

Total malfunctions (5-S)

S / 7 / 7

~ ?

Il~

2.

Malfunctions after EOP entry (1-2) 2 I 1 / 1

~ ';:>

6uA

3.

Abnormal evants (2-4) 4/2/3 D

M"

4.

Major transients (1-2) 2 I 2 / 2 tJ? -V "'"

5.

EOPs entered/requiring substantive actions (1-2) 1 / 2 / 1

~ 'i:>

NA

6.

EOP contingencies requiring substantive actions (0-2) 1 I 1 I 1 I/( ;;;::>

MIA

7.

Critical tasks (2-3) 2 I 2 I 2 V

.;> ~