Responses to E-RAI Set 2 to the License Renewal Application
ML12244A571
Person / Time
Site: Callaway Ameren icon.png
Issue date: 08/30/2012
From: Kanuckel L H
Ameren Missouri, Union Electric Co
To:
Office of Nuclear Reactor Regulation, Document Control Desk
Shared Package
ML122440687 List:
References
ULNRC-05902, TAC ME7715, TAC ME7716
Download: ML12244A571 (4)


Text

WAmeren MISSOURI Callaway Plant ::::::::::::::::::::::::::::::::::::::::::::::::::::::::::::::::::::::::::::::::::::::::::::::::::::::::::::::::::::::::::::::::::::::::::::::::::::::::::::::::::::::::::::::::::::::::::::::::::::::::::::::::::::::::::::::::::::::::::::::::::

August 30, 2012 ULNRC-05902 U.S. Nuclear Regulatory Commission Attn: Document Control Desk Washington, DC 20555-0001 Ladies and Gentlemen:

10 CFR 2.101 10 CFR 2.1 09(b) 10 CFR 50.4 10 CFR 50.30 10 CFR 51.53(c) 10 CFR 54 DOCKET NUMBER 50-483 CALLA WAY PLANT UNIT 1 UNION ELECTRIC CO. FACILITY OPERATING LICENSE NPF-30 RESPONSES TO E-RAI SET #2 TO THE CALLA WAY LRA

References:

1) ULNRC-05830 dated December 15, 2011 2) NRC Letter, "Requests For Additional Information for the Review of the Callaway Plant, Unit 1 License Renewal Application, Set 2 (T AC NOS ME7715 AND ME7716)," dated August 6, 2012. By the Reference I letter, Union Electric Company (Ameren Missouri) submitted a License Renewal Application (LRA) for Callaway Plant Unit 1. Reference 2 dated August 6, 2012 transmitted the second set of Requests for Additional Information (RAis) related to the environmental portion of our application.

Enclosure 1 contains Ameren Missouri's responses to the individual requests contained in the August 6, 2012 RAI. Enclosures 2 through 7 are referenced in Enclosure

1. If you have any questions with regard to these RAI responses, please contact me at (573) 823-9286 or Ms. Sarah Kovaleski at (314) 225-1134.

PO Box 620 Fulton, MD 65251 AmerenMissouri.com ULNRC-05902 August 30, 2012 Page2 I declare under penalty of perjury that the foregoing is true and correct. Sincerely, Executed on: A

30) 20 lZ... Les H. Kanuckel Manager, Engineering Design DS/SGK/nls

Enclosures:

1) Request for Additional Information (RAJ) E-RAI Set #2 Responses
2) 401 Certification for Union Electric Callaway Unit 1, dated August 7, 2012 3) Threatened and Endangered Species Correspondence
4) Standard Operating Procedures (SOP) for the Callaway Nuclear Plant Unit 2 Siting Study, Natural Resources Field Sampling and Analysis, November 30, 2007 (MACTEC 2007) 5) Meeting/Telecon Record dated 5-14-2012, Tetra Tech/Missouri Dept of Conservation
6) Ameren Transmission Vegetation Management Program 7) Preliminary Jurisdictional Wetland and Stream Determination Report for the Callaway Plant, June 19, 2009 ULNRC-05902 August 30, 2012 Page3 cc: U.S. Nuclear Regulatory Commission (Original)

Attn: Document Control Desk Washington, DC 20555-0001 Mr. Elmo E. Collins Regional Administrator U.S. Nuclear Regulatory Commission Region IV 1600 East Lamar Boulevard Arlington, TX 76011-4511 Senior Resident Inspector Callaway Resident Office U.S. Nuclear Regulatory Commission 8201 NRC Road Steedman, MO 65077 Ms. Carmen G. Fells Project Branch 1 Division of License Renewal Office ofNuclear Reactor Regulation U.S. Nuclear Regulatory Commission Mail Stop 0-11F1 Washington, DC 20555 Mr. Samuel Cuadrado De Jesus Project Branch 1 Division of License Renewal Office of Nuclear Reactor Regulation U.S. Nuclear Regulatory Commission Mail Stop 0-11F1 Washington, DC 20555 Mr. Fred Lyon Senior Project Manager, Callaway Plant Office of Nuclear Reactor Regulation U.S. Nuclear Regulatory Commission Mail Stop 0-8G 14 Washington, DC 20555-2738 Mr. Gregory A. Pick U.S. Nuclear Regulatory Commission Region IV 1600 East Lamar Boulevard Arlington, TX 7 6011-4511 ULNRC-05902 August 30, 2012 Page4 Index and send hardcopy to QA File A160.0761 Hardcopy:

Certrec Corporation 4150 International Plaza Suite 820 Fort Worth, TX 76109 (Certrec receives ALL attachments as long as they are non-safeguards and may be publicly disclosed.)

Electronic distribution for the following can be made via Tech Spec ULNRC Distribution:

A. C. Heflin F. M. Diya C. 0. Reasoner III D. W. Neterer L. H. Graessle J. S. Geyer S. A. Maglio R. Holmes-Bobo NSRB Secretary L. H. Kanuckel S. G. Kovaleski T. B. Elwood G. G. Yates E. Blocher (STARS PAM COB) Mr. Bill Muilenburg (WCNOC) Mr. Tim Hope (Luminant Power) Mr. Ron Barnes (APS) Mr. Tom Baldwin (PG&E) Mr. Mike Murray (STPNOC) Ms. Linda Conklin (SCE) Mr. John O'Neill (Pillsbury Winthrop Shaw Pittman LLP) Missouri Public Service Commission Mr. Dru Buntin (DNR)