Annual Radioactive Effluent Release Report, January Through December 2011
ML12068A379
Person / Time
Site: Columbia  Energy Northwest icon.png
Issue date: 02/29/2012
From:
Energy Northwest
To:
Office of Nuclear Material Safety and Safeguards, Office of Nuclear Reactor Regulation
References
GO2-12-031
Download: ML12068A379 (57)


Text

NORTH WEST Columbia Generating Station Annual Radioactive Effluent Release Report January through December 2011

-I--

REFERENCES:

10 CFR 50.36a(a)(2) 10 CFR 72.44(d)(3)

CGS Technical Specification 5.6.2 ISFSI Technical Specification 5.4.c Columbia Generating Station Annual Radioactive Effluent Release Report January through December 2011 Energy Northwest Submitted February 2012

Table of Contents

1.0 INTRODUCTION

1 2.0 LIQUID EFFLUENTS..............................................................................

1 3.0 GASEOUS EFFLUENTS.......................................................................

1 Gaseous Effluent Tables......................................................................

5 Table 3-0 10 CFR Part 50 Appendix I Dose Compliance..................... 5 Table 3-1 Main Plant Vent Releases................................................ 6 Table 3-2 Turbine Building Releases.............................................. 8 Table 3-3 Radwaste Building Releases..........................................

10 Table 3-4 Summation of Releases................................................... 12 Table 3-5 Gaseous Purges and Vents.............................................. 13 Table 3-6 Lower Limits of Detection..............................................

14 4.0 SOLID RADWASTE.............................................................................

15 Solid Radwaste Information required by the Offsite Dose Calculation Manual. 15 C la s s A......................................................................................... 15 C la ss B...................................................................................... 16 C la s s C......................................................................................... 16 Solid Radwaste Information Recommended by NRC Regulatory Guide 1.21.... 18 Solid waste shipped offsite for burial or disposal (not irradiated fuel)......... 18 Irradiated Fuel Shipments (Disposition)............................................ 20 5.0 METEOROLOGICAL DATA................................................................

21 Joint Frequency Distribution Tables for 2011...........................................

22 Table 5-1 1st Quarter Average, 33 Ft Above Ground Level (AGL).......... 22 Table 5-2 1st Quarter Average, 245 Ft AGL.................................... 24 Table 5-3 2nd Quarter Average, 33 Ft AGL..................................... 26 Table 5-4 2nd Quarter Average, 245 Ft AGL................................... 28 Table 5-5 3rd Quarter Average, 33 Ft AGL....................................

30 Table 5-6 3rd Quarter Average, 245 Ft AGL.................................... 32 Table 5-7 4th Quarter Average, 33 Ft AGL......................................... 34 Table 5-8 4th Quarter Average, 245 Ft AGL..................................... 36 Table 5-9 Year 2011, 33 Ft AGL............................ I......................... 38 Table 5-10 Year 2011, 245 Ft AGL................................................ 40 Table 5-11 Year 2011 Growing Season - Daylight Hours................... 42 Columbia Generating Station i

2011 Radioactive Effluent Report

6.0 DOSE ASSESSMENT -- IMPACT ON MAN.........................................

44 Dose Tables...................................................................................

48 Table 6-1 Summary of Doses from Gaseous Effluents...................... 48 Table 6-2 50-Mile Population Dose from Gaseous Effluents............... 51 7.0 REVISIONS TO THE ODCM.................................................................

52 8.0 REVISIONS TO THE PROCESS CONTROL PROGRAM (PCP).......... 52 9.0 NEW OR DELETED LOCATIONS FOR DOSE ASSESSMENTS AND/OR ENVIRONMENTAL MONITORING LOCATIONS.................. 53 10.0 MAJOR CHANGES TO RADIOACTIVE LIQUID, GASEOUS, AND SOLID WASTE TREATMENT SYSTEMS.............................................

53 Columbia Generating Station ii 2011 Radioactive Effluent ReDort I.

1.0 Introduction This report has been prepared in compliance with Parts 50 and 72 of Title 10 of the Code of Federal Regulations (CFR), specifically 10 CFR 50.36a(a)(2) and 10 CFR 72.44(d)(3), Independent Spent Fuel Storage Installation (ISFSI) Technical Specification 5.4.c, and Columbia Generating Station (CGS) Technical Specification 5.6.2. It includes a summary of the quantities of radioactive liquid and gaseous effluents and solid radwaste released from Columbia Generating Station during calendar year 2011. Effluent data is summarized on a quarterly basis.

Throughout this report, units of activity and dose are as defined in 10 CFR 20.1004, 20.1005, and Nuclear Regulatory Commission (NRC) Regulatory Guide 1.109-1977.

The United States National Council on Radiation Protection published Report #160 in 2009 which can serve to put radiation dose into perspective for the reader of this report. It was determined that the average yearly dose to a person living in the United States is 620 mrem from all sources. Of this, -50% is attributed to natural sources (radiation from gaseous radon, cosmic or space radiation, natural radioactive material in the ground, and natural radioactive materials in our bodies).

About 48% is attributed to diagnostic and therapeutic medical exposure. Radiation dose from nuclear power was grouped into a category comprising <0.1% of the total.

2.0 Liquid Effluents No planned releases of contaminated liquids from the liquid radwaste processing system were discharged to the Columbia River from Columbia Generating Station during calendar year 2011. The last planned discharge took place in 1998.

In 2011, there were no known leaks to the environment of radioactive liquids.

3.0 Gaseous Effluents The gaseous radwaste effluents from Columbia Generating Station were released from three (3) release points:

Main Plant Vent -- mixed mode release Turbine Building - mixed mode release Radwaste Building -- ground level release The gaseous source terms from each release point are listed in Tables 3-1, 3-2, and 3-3. The activation gas argon-41 is included in these tables under fission gases to allow a match with the fission and activation gas totals of Table 3-4. Table 3-4 provides a summation of the total activity released, the average release rate, gross alpha radioactivity, and the estimated total error associated with the measurements of radioactivity in the gaseous effluents.

Columbia Generating Station I

2011 Radioactive Effluent Report

Radioactivity measurements for gaseous effluent releases are performed for fission and activation gases by collecting the samples in a Marinelli beaker and analyzing them using gamma spectroscopy. Air is analyzed for tritium by collection of water vapor on a desiccant with subsequent distillation and liquid scintillation counting.

Particulates and iodines are sampled continuously and the sample media (particulate filters and charcoal cartridges) are analyzed weekly using gamma spectroscopy. Each quarter a chemical separation process is used to isolate strontium from the composite particulate filters and quantification is accomplished with liquid scintillation detection. The average energy per disintegration of fission and activation gases is not included in this report as it is not required by Technical Specifications and is not used for gaseous effluent release rate limit calculations.

When a radioisotope is not positively identified at levels greater than the Minimum Detectable Activity (MDA), a value of zero is used for release concentrations and offsite dose assessments. Table 3-6 contains the Lower Limit of Detection (LLD) values corresponding to the sampling methods and analytical instruments used for each principal radioisotope.

Dose calculations were performed for releases using the NRC XOQDOQ and GASPAR II computer programs and parameter values as described in the Offsite Dose Calculation Manual (ODCM) with some exceptions. A Self-Assessment identified opportunities for improving the accuracy of values presented in ODCM Table 3-13 which describe the characteristics of gaseous effluent release points.

The following table (3.0-A) shows values used as input to XOQDOQ which differ from those presented in the ODCM table.

Columbia Generating Station 2

2011 Radioactive Effluent Report

Table 3.0-A: Deviations from Input Parameters in ODCM Table 3-13 Reactor Radwaste I

Bldg Bldg ITurbine Bldg Vent Velocity (m/s)

Value in ODCM 1

10.9 3.4 1

19.5 Value used in XOQDOQ

'10.9 0

21.0 XOQDOQ requires the vertical exit velocity. Release from the Radwaste bldg is horizontal. Release from the Turbine bldg is vertical and was recalculated.

Vent Inside Diameter (m)

IValue in ODCM I

2.1 3.8 3.3 Value used in XOQDOQ 2.1 0

3.0 NUREG/CR-2919 recommends a value of 0 for ground mode release points (Radwaste bldg). The Turbine bldg value was recalculated.

Average annual heat flow from release point [Heat Emission Rate] (cal/sec)

IValue in ODCM I 1.06E+06 2.90E+06 9.10E+05 Value used in XOQDOQ 1.59E+05 1.04E+05 8.02E+05 The heat emission rates were recalculated The XOQDOQ program was also provided with updated terrain elevations out to a 25-mile radius of Columbia Generating Station in each sector. The above changes allowed better modeling of plume vertical momentum and buoyancy resulting in more accurate dispersion and deposition values from those presented in ODCM Tables 3-3, 3-10, and 3-11. The ODCM is in the process of revision to reflect the above changes.

Quarterly and annual doses to the potentially highest-exposed Member of the Public at and beyond the site boundary were calculated. In addition, quarterly and annual doses were calculated at actual resident locations identified in the annual land use census. ODCM limits are based 10 CFR 20 and Appendix I to 10 CFR 50.

The threshold for air dose applies to fission and activation gases and is ten (10) mrad for beta and five (5) mrad for gamma quarterly and twenty (20) mrad for beta and ten (10) mrad for gamma annually. The threshold for organ dose applies to iodine, tritium, and particulates with half-lives greater than eight days and is seven and a half (7.5) mrem quarterly and fifteen (15) mrem annually. For fission and activation gases the dose rate limits are less than or equal to 500 mrem per year to the whole body and less than or equal to 3000 mrem per year to the skin. For iodines, particulates, and tritium the dose rate limit is less than or equal to 1500 mrem/year to any organ.

Dose calculations were also conducted for Members of the Public within the site boundary. The results are discussed and tabulated in Section 6.0.

It is estimated that approximately 9.53E-03 Curies of tritium were released through unmonitored vents of the heating steam system within and outside the main power block (Turbine, Radwaste, Reactor, and General Services buildings).

No additional spent fuel storage containers (SFSC) were added to the ISFSI facility in calendar year 2011. A total of twenty seven (27) SFSCs were in place in the ISFSI facility at the end of 2011. There were twelve SFSCs loaded in 2008 that were considered Operable (i.e. no measurable leakage) but nonconforming based Columbia Generating Station 3

2011 Radioactive Effluent Report

on the vendor failing to leak test the canisters during fabrication. This was communicated to the NRC via Energy Northwest letter, G02-10-157 (ADAMS Accession Number ML103070299), submitted October 27, 2010. Energy Northwest received a response from the NRC dated July 7, 2011, G12-11-106 (ADAMS Accession Number ML111880244), which indicated continued use of the affected canisters is acceptable with no further action required. Since the contents of the affected canisters and the canisters themselves meet all other storage requirements, Energy Northwest considers the nonconforming condition resolved.

All SFSCs are Operable and, as such, are performing as designed. Based on compliance with ISFSI Technical Specification 3.1.1 during 2011, there are no effluents from this facility.

Incidents of effluent monitor inoperability greater than 30 days:

During 2011, the turbine building gaseous effluent flow rate monitor (ODCM RFO 6.1.2 Function 4 d) failed during ODCM surveillance activity on May 30, 2011. The monitor was out of service greater than 30 days because the flow transmitter was no longer available and did not have a recommended replacement from the original equipment manufacturer. A decision was made to repair the item using an experienced third party shop. Despite two attempts to repair the component the repair was unsuccessful and the unit was determined to be irreparable. A design change was approved and completed which took the original pneumatic signal, converted it to an electrical signal, and then converted it back into a pneumatic signal that could be transmitted to the Square Root Converter. This involved adding two new signal units and a power supply. The monitor was returned to service on December 23, 2011. The total time out of service was 207 days.

The turbine service water system gross radioactivity monitor (ODCM RFO 6.1.1 Function 3) was declared non-functional on August 10, 2011, to validate calculations of the ODCM alarm setpoint established at the time of the monitor installation in August of 2006. The initial alarm setpoint was based on estimates of instrument performance. It was returned to service on September 13, 2011, (34 days) following a statistical analysis of the observed background and a review of instrument error estimates.

The reactor building elevated discharge radiation monitor (ODCM RFO 6.1.2 Function 3 a) was taken out of service on March 15, 2011, to replace a malfunctioning regulating transformer. Although the new transformer was energized on April 1, 2011, the discharge radiation monitor was left out of service during the refueling outage. On June 26, 2011, the detectors were returned to service but within hours, power from the regulating transformer was lost. The transformer was placed in manual and the loads were energized on July 26, 2011.

The monitor was finally declared functional on August 31, 2011. The total out of service time was 169 days.

Columbia Generating Station 4

2011 Radioactive Effluent Report

Gaseous Effluent Tables Table 3-0 10 CFR Part 50 Appendix I Dose Compliance Report Period: January -- December 2011 I 1st Quarter 12nd Quarter 13rd Quarter I 4th QuarterI Year*

I Noble Gas Gamma Air Dose (mrad) 2.19E-02 7.73E-04 O.OOE+00 3.12E-03 2.08E-02 ODCM Limit 5

5 5

5 10

% of Limit 4.38E-01 1.55E-02 O.OOE+00 6.24E-02 2.08E-01 Beta Air Dose (mrad) 7.74E-03 2.74E-04 0.OOE+00 1.1OE-03 7.35E-03 ODCM Limit 10 10 10 10 20

% of Limit 7.74E-02 2.74E-03 O.OOE+00 1.1OE-02 3.68E-02 Iodine-131, Iodine-133, Tritium, and Particulates with half-lives greater than eight days.

Organ Dose (mrem) 2.37E-02 1.25E-03 1.13E-03 3.43E-03 2.40E-02 ODCM Limit 7.5 7.5 7.5 7.5 15

% of Limit 3.16E-01 1.67E-02 1.50E-02 4.58E-02 1.60E-01

  • Calculated quarterly doses cannot be directly compared to the annual doses.

Each above listed quarterly dose is the highest calculated dose based on a number of variables. Variables that make comparison difficult include location, meteorological data (quarterly joint frequency distribution (JFD) tables vs. annual JFD tables), receptor age, target organ, and characteristics of the emitted radionuclides. In the above chart, all dose is calculated to a hypothetical person at the site boundary.

Columbia Generating Station 5

2011 Radioactive Effluent Report

Table 3-1 Main Plant Vent Releases Fission Gases and lodines Report Period: January -- December 2011 1st 2nd 3rd 4th Quarter Quarter Quarter Quarter Year Nuclides Released (Ci)

(Ci)

(Ci)

(Ci)

(Ci)

A. Fission gases krypton-85

<MDA

<MDA

<MDA

<MDA

<MDA krypton-85m

<MDA

<MDA

<MDA

<MDA

<MDA krypton-87

<MDA

<MDA

<MDA

<MDA

<MDA krypton-88

<MDA

<MDA

<MDA

<MDA

<MDA xenon-133

<MDA

<MDA

<MDA

<MDA

<MDA xenon-133m

<MDA

<MDA

<MDA

<MDA

<MDA xenon-135

<MDA 1.48E-02

<MDA

<MDA 1.48E-02 xenon-135m

<MDA

<MDA

<MDA

<MDA

<MDA xenon-138

<MDA

<MDA

<MDA

<MDA

<MDA Others argon-41 6.20E+01 2.62E+00

<MDA 1.06E+01 7.52E+01 Total for period

  • 6.20E+01 2.64E+00 O.OOE+00 1.06E+01 7.52E+01 B. lo dines iodine-131 2.56E-05 4.73E-06

<MDA

<MDA 3.04E-05 iodine-132

<MDA

<MDA

<MDA

<MDA

<MDA iodine-133

<MDA

<MDA

<MDA

<MDA

<MDA iodine-134

<MDA

<MDA

<MDA

<MDA

<MDA iodine-135

<MDA

<MDA

<MDA

<MDA

<MDA Total for period

  • 2.56E-05 4.73E-06 0.OOE+00 0.OOE+00 3.04E-05 MDA = Less than the mass or volume).

"a posteriori" minimal detectable activity (microcuries per unit

  • MDA values are not included in the totals.

Columbia Generating Station 6

2011 Radioactive Effluent Report Columbia Generating Station 6

2011 Radioactive Effluent Report

Table 3-1 Main Plant Vent Releases (Continued)

Particulates and Tritium Report Period: January -- December 2011 1st 2nd 3rd 4th Quarter Quarter Quarter Quarter Year Nuclides Released (Ci)

(Ci)

(Ci)

(Ci)

(Ci)

C. Particulates strontium-89

<MDA 3.75E-07 1.66E-07 4.01E-07 9.42E-07 strontium-90

<MDA

<MDA 1.18E-07

<MDA 1.18E-07 cesium-1 34

<MDA

<MDA

<MDA

<MDA

<MDA cesium-I 37

<MDA

<MDA

<MDA

<MDA

<MDA barium-lanthanum -140

<MDA

<MDA

<MDA

<MDA

<MDA silver-1l0m

<MDA

<MDA

<MDA

<MDA

<MDA cerium-141

<MDA

<MDA

<MDA

<MDA

<MDA cerium-144

<MDA

<MDA

<MDA

<MDA

<MDA cobalt-58

<MDA 5.90E-06 1.56E-05

<MDA 2.15E-05 cobalt-60 4.71E-06 3.75E-05 1.43E-04 3.08E-06 1.88E-04 iron-59

<MDA

<MDA 8.66E-06

<MDA 8.66E-06 manganese-54

<MDA 9.17E-06 2.28E-05

<MDA 3.20E-05 zinc-65 3.55E-06 2.12E-05 5.23E-05

<MDA 7.70E-05 chrome-51

<MDA

<MDA 9.45E-06

<MDA 9.45E-06 antimony-125

<MDA

<MDA

<MDA

<MDA

<MDA Total for period*

8.27E-06 7.4 1E-05 2.52E-04 3.48E-06 3.38E-04 Others with T 1/2 < 8 days arsenic-76

<MDA

<MDA

<MDA

<MDA

<MDA bromine-82

<MDA

<MDA

<MDA 5.43E-06 5.43E-06 copper-64

<MDA

<MDA

<MDA

<MDA

<MDA molybdenum-99

<MDA

<MDA

<MDA

<MDA

<MDA rhenium-188

<MDA

<MDA

<MDA

<MDA

<MDA sodium-24

<MDA

<MDA

<MDA

<MDA

<MDA technetium-99m

<MDA

<MDA

<MDA

<MDA

<MDA zinc-69m

<MDA

<MDA

<MDA

<MDA

<MDA Total with T 1/2 < 8 days*

0.OOE+00 0.OOE+00 0.OOE+00 5.43E-06 5.43E-06 D. Tritium tritium 5.OOE-01 4.79E-01 3.17E-01 I 8.21E-01 2.12E+00 MDA = Less than the "a posteriori" minimal detectable activity (microcuries per unit mass or volume).

  • MDA values are not included in the totals.

Columbia Generating Station 7

2011 Radioactive Effluent Report Columbia Generating Station 7

2011 Radioactive Effluent Report

Table 3-2 Turbine Building Releases Fission Gases and lodines Report Period: January -- December 2011 1 1st 2nd 3rd 4th J Quarter Quarter Quarter Quarter Year Nuclides Released (Ci)

(Ci)

(Ci)

(Ci).

(Ci)

A. Fission gases krypton-85

<MDA

<MDA

<MDA

<MDA

<MDA krypton-85m

<MDA

<MDA

<MDA

<MDA

<MDA krypton-87

<MDA

<MDA

<MDA

<MDA

<MDA krypton-88

<MDA

<MDA

<MDA

<MDA

<MDA xenon-133

<MDA

<MDA

<MDA

<MDA

<MDA xenon-133m

<MDA

<MDA

<MDA

<MDA

<MDA xenon-135

<MDA

<MDA

<MDA

<MDA

<MDA xenon-135m

<MDA

<MDA

<MDA

<MDA

<MDA xenon-138

<MDA

<MDA

<MDA

<MDA

<MDA Others argon-41

<MDA

<MDA

<MDA

<MDA

<MDA Total for period

  • 0.OOE+00 0.OOE+00 0.OOE+00 0.OOE+00 0.OOE+00 B. lodines iodine-131 1.13E-04 1.03E-05

<MDA

<MDA 1.23E-04 iodine-132

<MDA

<MDA

<MDA

<MDA

<MDA iodine-133 7.93E-05

<MDA

<MDA

<MDA 7.93E-05 iodine-134

<MDA

<MDA

<MDA

<MDA

<MDA iodine-135

<MDA

<MDA

<MDA

<MDA

<MDA Total for period

  • 1.92E-04 1.03E-05 0.OOE+00 0.OOE+00 2.02E-04 MDA = Less than the "a posteriori" minimal detectable activity (microcuries per unit mass or volume).
  • MDA values are not included in the totals.

Columbia Generating Station 8

2011 Radioactive Effluent Report Columbia Generating Station 8

2011 Radioactive Effluent Report

Table 3-2 Turbine Building Releases (Continued)

Particulates and Tritium Report Period: January -- December 2011 1st 2nd 3rd 4th Quarter Quarter Quarter Quarter Year Nuclides Released (Ci)

(Ci)

(Ci)

(Ci)

(Ci)

C. Particulates strontium-89 8.97E-06

<MDA 1.17E-06 4.41E-06 1.45E-05 strontium-90

<MDA

<MDA

<MDA

<MDA

<MDA cesium-134

<MDA

<MDA

<MDA

<MDA

<MDA cesium-137

<MDA

<MDA

<MDA

<MDA

<MDA barium-1 anthanum -140

<MDA

<MDA

<MDA

<MDA

<MDA cerium-141

<MDA

<MDA

<MDA

<MDA

<MDA cerium-144

<MDA

<MDA

<MDA

<MDA

<MDA cobalt-58

<MDA

<MDA

<MDA

<MDA

<MDA cobalt-60 5.58E-05 5.64E-06 8.48E-06 6.65E-06 7.66E-05 iron-59

<MDA

<MDA

<MDA

<MDA

<MDA manganese-54

<MDA

<MDA

<MDA

<MDA

<MDA zinc-65 3.67E-04 2.45E-05

<MDA

<MDA 3.91E-04 chrome-51

<MDA

<MDA

<MDA

<MDA

<MDA Total for period*

4.3 1E-04 3.01E-05 9.65E-06 1.11 E-05 4.82E-04 Others with T 1/2 < 8 days molybdenum-99

<MDA

<MDA

<MDA

<MDA

<MDA Total with T 1/2 < 8 days*

0.OOE+00 0.OOE+00 0.OOE+00 0.OOE+00 O.OOE+00 D. Tritium tritium 5.90E+0O I 1.74E+00I 6.66E-02 I 3.16E+00 1.09E+01 MDA = Less than the "a posteriori" minimal detectable activity (microcuries per unit mass or volume).

  • MDA values are not included in the totals.

Columbia Generating Station 9

2011 Radioactive Effluent Report

Table 3-3 Radwaste Building Releases Fission Gases and lodines Report Period: January -- December 2011 1st 2nd 3rd 4th Quarter Quarter Quarter Quarter Year Nuclides Released (Ci)

(Ci)

(Ci)

(Ci)

(Ci)

A. Fission gases krypton-85

<MDA

<MDA

<MDA

<MDA

<MDA krypton-85m

<MDA

<MDA

<MDA

<MDA

<MDA krypton-87

<MDA

<MDA

<MDA

<MDA

<MDA krypton-88

<MDA

<MDA

<MDA

<MDA

<MDA xenon-133

<MDA

<MDA

<MDA

<MDA

<MDA xenon-133m

<MDA

<MDA

<MDA

<MDA

<MDA xenon-135

<MDA

<MDA

<MDA

<MDA

<MDA xenon-135m

<MDA

<MDA

<MDA

<MDA

<MDA xenon-138

<MDA

<MDA

<MDA

<MDA

<MDA Others argon-41

<MDA

<MDA

<MDA

<MDA

<MDA Total for period*

0.OOE+00 0.OOE+0O 0.OOE+00 0.OOE+00 0.00E+00 B. Iodines iodine-131 2.69E-05 2.97E-06

<MDA

<MDA 2.99E-05 iodine-132

<MDA

<MDA

<MDA

<MDA

<MDA iodine-133 3.73E-06

<MDA

<MDA

<MDA 3.73E-06 iodine-134

<MDA

<MDA

<MDA

<MDA

<MDA iodine-135

<MDA

<MDA

<MDA

<MDA

<MDA Total for period

  • 3.06E-05 2.97E-06 0.OOE+00 0.OOE+00 3.36E-05 MDA = Less than the "a posteriori" minimal detectable activity mass or volume).
  • MDA values are not included in the totals.

(microcuries per unit Columbia Generating Station 10 2011 Radioactive Effluent Report

Table 3-3 Radwaste Building Releases (Continued)

Particulates and Tritium Report Period: January -- December 2011 1st 2nd 3rd 4th Quarter Quarter Quarter Quarter Year Nuclides Released (Ci)

(Ci) j (Ci)

(Ci)

(Ci)

C. Particulates strontium-89 6.7 1E-07

<MDA 5.84E-06 1.32E-07 6.65E-06 strontium-90

<MDA

<MDA 1.47E-06

<MDA 1.47E-06 cesium-134

<MDA

<MDA

<MDA

<MDA

<MDA cesium-i137

<MDA

<MDA

<MDA

<MDA

<MDA barium-1 anthanum-1 40

<MDA

<MDA

<MDA

<MDA

<MDA cerium-141

<MDA

<MDA

<MDA

<MDA

<MDA cerium-144

<MDA

<MDA

<MDA

<MDA

<MDA cobalt-58

<MDA

<MDA

<MDA

<MDA

<MDA cobalt-60 9.0 1E-07

<MDA

<MDA

<MDA 9.01E-07 iron-59

<MDA

<MDA

<MDA

<MDA

<MDA manganese-54

<MDA

<MDA

<MDA

<MDA

<MDA zinc-65 8.02E-07

<MDA

<MDA

<MDA 8.02E-07 Total for period*

2.37E-06 0.OOE+00 7.31E-06 1.32E-07 9.82E-06 Others with T 1/2 < 8 days molybdenum-99

<MDA

<MDA

<MDA

<MDA

<MDA Total with T 1/2 < 8 days*

0.OOE+00 0.OOE+00 O.OOE+00 0.00E+00 0.00E+00 D. Tritium I

tritium I9.90E-021 6.O1E-021 6.15E-021 1.21E-01 I 3.41E-01 I MDA = Less than the "a posteriori" minimal detectable activity (microcuries per unit mass or volume).

  • MDA values are not included in the totals.

Columbia Generating Station 11 2011 Radioactive Effluent Report Columbia Generating Station 11 2011 Radioactive Effluent Report

Table 3-4 Summation of Releases Gaseous Effluents Report Period: January -- December 2011 1 st 2nd 3rd 4th Total Quarter Quarter Quarter Quarter I Year

%Error A. Fission and activation gases Total release (Ci) 6.20E+01 2.64E+00 I <MDA 1.06E+01 I7.52E+01 4.30E+11 Average release rate (pCi/s) 7.89E+00 3.36E-01 I <MDA 1.35E+00 2.39E+OO Percent of OCM limit (%) 1.67E-02 5.91E-04 I 0.OOE+0I 2.38E-03 3.98E-03 B. lodines Total 1-131 (Ci) 1.65E&04 1.80E-05

<MDA

<MDA 1.83E-04 4.60E+01 Average release rate (pCi/s) 2.10E-05 2.29E-06

<MDA

<MDA 5.83E-06 Percent of ODCM limit (%)

2.46E-05 2.48E-06 O.OOE+00 0.OOE+00

1. 16E-05 C. Particulates Particulates with half-lives

>8 days (Ci) 4.42E-04 1.04E-04 2.69E-04 1.47E-05 8.30E-04 4.50E+01 Average release rate (pCi/s) 5.62E-05 1.33E-05 3.42E-05 1.87E706 2.64E-05 Percent of ODCM limit(%)

1.41E-01 1.64E-02 1.01E-02 1.18E-01 6.41E-02 Gross alpha radioactivity (Ci) 7.97E-07 4.36E-07 5.03E-07 1.41 E-06 3.15E-06 7.30E+01 D. Tritium Total release (Ci) 6.50E+00 2.28E+00 4.45E-01 4.10E+00 1.33E+01 2.60E+01 Average release rate (pCi/s) 8.27E-01 2.90E-01 5.66E-02 5.22E-01 4.24E-01 Percent of ODCM limit (%)

3.09E-05 6.97E-06 4.07E-06 1.50E-05 9.93E-06 MDA = Less than the "a posteriori" minimal detectable activity (microcuries per unit mass or volume).

ODCM release rate limits are based on dose rate. For fission and activation gases the dose rate limits are less than or equal to 500 mrem/year to the whole body and less than or equal to 3000 mrem/year to the skin. For 1-131, particulates, and tritium the dose rate limit is less than or equal to 1500 mrem/year to any organ.

The ODCM dose factors and the highest site boundary dispersion value for each period were used in the calculation.

  • Measurement errors are sample-specific. The values reported represent an approximate overall error. The major contributors of this error are measurements associated with sample volume, release point flow rates, and estimates of plateout factors.

Columbia Generating Station 12 2011 Radioactive Effluent Report

Table 3-5 Gaseous Purges and Vents Report Period: January -- December 2011 Total Maximum Mean Type Purge Vent Number 3.OOE+00 2.20E+0 1 Total Time (hr.)

4.97E+01 3.20E+01 Maximum Time (hr.)

4.39E+O 1 5.92E+00 Minimum Time (hr.)

2.37E+00 4.3 3E-0l Mean Time (hr.)

1.66E+01 1.45 E+00 Columbia Generating Station is a continuous release plant. All purges and vents are discharged through the Standby Gas Treatment System and released through the reactor building stack which is, by procedure and design, sampled and continuously monitored for radioactive gaseous waste.

Columbia Generating Station 13 2011 Radioactive Effluent Report

Table 3-6 Lower Limits of Detection Gasgous Effluents Report Period: January -- December 2011 Fission Gases Required LLDT Achieved Analysis Nuclide (pCi/cc)

LLD (pCi/cc) krypton-87 1.OOE-04 1.05E-08 krypton-88 1L.OOE-04 1.29E-08 xenon-133 1.OOE-04 1.OOE-08 xenon-133m 1.OOE-04 3.25E-08 xenon-135 1.OOE-04 3.77E-09 xenon-138 1.OOE-04 4.48E-08 lodines iodine-131 1.OOE-12 5.79E-14 iodine-133 1.OOE-10 1.1OE-12 Particulates Tritium hydrogen-3 I1.OOE-06 5.85E-11 t From ODCM Table 6.2.2.1-1 Columbia Generating Station 14 2011 Radioactive Effluent Report

4.0 Solid Radwaste This section of the annual effluent report provides information required by the Columbia Generating Station Offsite Dose Calculation Manual and recommended by Nuclear Regulatory Commission Regulatory Guide 1.21-1974.

Solid Radwaste Information required by the Offsite Dose Calculation Manual January -- December 2011 Class A

1.

Container Volumes 8GALDRUM 1.6 ft3 30 GAL DRUM 4.0 ft3 55 GAL DRUM 7.5 ft3 Liquid Tote 42.8 ft3 B-25 Steel Box 96 ft3 PL8-120 Polyethylene HIC 120.3 ft3 EL-142 Polyethylene HIC 132.4 ft3 B-25 Overpack Steel Box 138 ft3 ES-190 Steel Liner 170.2 ft3 PL14-170 Polyethylene HIC 170.8 ft3 14-170 Steel Liner 180.1 ft3 Intermodal Container 675 ft3 Water Box Bag 887 ft3 20' SeaLand Container 1280 ft3 Condenser Mod Bag 6310 ft3

2.

Total Curies 2.89E+02 Ci

3.

Principal Radionuclides 777'~W.,..-u Co-60 1.09E+02 3.77E+01 Zn-65 8.61 E+01 2.98E+01 Fe-55 4.70E+01 1.63E+01 Mn-54 1.24E+01 4.30E+00 Cr-51 1.04E+01 3.61 E+00 Co-58 8.38E+00 2.91 E+00 Ni-63 7.76E+00 2.69E+00 C-14 1.95E+00 6.76E-01 Nb-95 1.54E+00 5.35E-01 Zr-95 1.07E+00 3.70E-01 Sb-1 25 7.37E-01 2.56E-01 Columbia Generating Station 15 2011 Radioactive Effluent Report

Cs-137 6.77E-01 2.35E-01 Fe-59 5.42E-01 1.88E-01 Ag-1 1Om 5.16E-01 1.79E-01 Ni-59 2.70E-01 9.35E-02 Sb-124 1.48E-01 5.13E-02 Sr-89 9.91 E-02 3.44E-02 H-3 8.26E-02 2.86E-02 La-140 2.30E-02 7.97E-03 Ba-140 2.1OE-02 7.29E-03 Sr-90 1.56E-02 5.42E-03 1-131 1.07E-02 3.72E-03 Pu-241

  • 4.39E-03 1.52E-03 Cm-242 3.97E-04 1.38E-04 Pu-239 3.44E-04 1.19E-04 Ce-141 3.06E-04 1.06E-04 Tc-99 1.39E-04 4.82E-05
  • This isotope was erroneously reported as Pu-231
4.

Source Resins DAW Irradiated Components in the 2010 effluent report.

2.71 E+02 Ci 1.83E+01 Ci 0.OOE+00 Ci Other (Sealed Source, Mixed Waste,

& Liquid Waste) 1.39E-01 Ci

5.

Type of Container All containers shipped as Limited Quantity, LSA, SCO or Radioactive material in IP-1, IP-2, Type A, or Type B (including casks) as appropriate.

6.

Solidification Agent None Class B There were no Class B shipments made during calendar year 2011 Class C

1.

Container Volumes EL-142 Polyethylene HIC

2.

Total Curies 3.57E+01 Ci 132.4 ft3 Columbia Generating Station 16 2011 Radioactive Effluent Report

3.

Principal Radionuclides Co-60 1.68E+01 4.71 E+01 Zn-65 8.66E+00 2.43E+01 Fe-55 7.19E+00 2.01E+01 Ni-63 1.92E+00 5.38E+00 Mn-54 7.99E-01 2.24E+00 Cs-137 1.45E-01 4.07E-01 Co-58 1.03E-01 2.89E-01 Ag-110m 3.37E-02 9.44E-02 H-3 1.60E-02 4.48E-02 C-14 8.05E-03 2.26E-02 Sr-90 3.29E-03 9.22E-03 Ni-59 3.19E-03 8.94E-03 Sr-89 8.75E-04 2.45E-03 Pu-241 7.73E-04 2.17E-03 Tc-99 3.01 E-05 8.44E-05 Cm-243 9.35E-06 2.62E-05 Cm-242 7.23E-06 2.03E-05 Am-241 6.66E-06 1.87E-05 Pu-238 6.57E-06 1.84E-05 Pu-239 4.51 E-06 1.26E-05 1-129 8.29E-07 2.32E-06

4.

Source Resins DAW 3.55E+01 Ci 0.OOE+00 Ci 0.OOE+00 Ci Irradiated Components Other (Sealed Sources) 1.42E-01 Ci

5.

Type of Container All containers shipped as Type B (including casks).

6.

Solidification Agent None Columbia Generating Station 17 2011 Radioactive Effluent Report

Solid Radwaste Information Recommended by NRC Regulatory Guide 1.21 January -- December 2011 Solid waste shipped offsite for burial or disposal (not irradiated fuel).

1.

Type of Waste Annual Unit Cumulative Est. Total Error %

Waste Stream

a. Spent resins, filter sludge, m3 9.77E+01 evaporator bottoms, etc.

Ci 3.06E+02 2.5E+01%

b. Dry Active Waste mo 3.58E+03 Ci 1.83E+01 2.5E+01%
c. Irradiated Components m3 O.OOE+00 Ci O.OOE+00 None
d. Other Waste (Sealed Source, m

6.48E+01 mixed waste, & Liquid Waste)

Ci 2.81 E-01 2.5E+01 %

2.

Estimate of major nuclide composition (by type of waste)

a.

Dewatered Spent Resins -- All Classes Co-60 1.20E+02 3.93E+01 Zn-65 9.03E+01 2.95E+01 Fe-55 5.40E+01 1.77E+01 Mn-54 1.27E+01 4.16E+00 Ni-63 9.49E+00 3.11E+00 Co-58 6.26E+00 2.05E+00 Cr-51 5.80E+00 1.90E+00 C-14 1.96E+00 6.40E-01 Nb-95 1.33E+00 4.35E-01 Zr-95 9.36E-01 3.06E-01 Sb-125 6.18E-01 2.02E-01 Fe-59 5.42E-01 1.77E-01 Cs-137 5.06E-01 1.66E-01 Ag-110m 4.83E-01 1.58E-01 Ni-59 2.73E-01 8.93E-02 Sb-124 1.06E-01 3.47E-02 H-3 9.33E-02 3.05E-02 Sr-89 6.83E-02 2.24E-02 La-140 2.30E-02 7.52E-03 Columbia Generating Station 18 2011 Radioactive Effluent Report Columbia Generating Station 18 2011 Radioactive Effluent Report

b.

Ba-140 2.1OE-02 6.88E-03 Sr-90 1.79E-02 5.86E-03 1-131 1.07E-02 3.51E-03 Pu-241 5.16E-03 1.69E-03 Dry Active Waste (DAW) -- All Classes Cr-51 4.59E+00 2.51 E+01 Zn-65 4.41 E+00 2.42E+01 Co-58 2.21 E+00 1.21 E+01 Mn-54 5.05E-01 2.77E+00 Cs-137 2.62E-01 1.43E+00 Nb-95 2.13E-01 1.17E+00 Fe-55 1.89E-01 1.03E+00 Zr-95 1.32E-01 7.22E-01 Sb-125 1.18E-01 6.48E-01 Ni-63 9.81 E-02 5.37E-01 Ag-110m 6.60E-02 3.62E-01 Sb-124 4.16E-02 2.28E-01 Sr-89 3.14E-02 1.72E-01 H-3 5.30E-03 2.90E-02 C-14 2.43E-03 1.33E-02 Sr-90 1.01E-03 5.52E-03 Cm-242 8.05E-05 4.41 E-04 Pu-239 7.93E-05 4.34E-04 Irradiated Components None Other Waste (Sealed Source & Mixed Waste)

Ni-63 9.02E-02 3.21 E+01 Cs,137 5.43E-02 1.93E+01 Co-60 4.03E-02 1.43E+01 Cr-51 3.72E-02 1.32E+01 Zn-65 32E-21.

16E1+01 C.

d.

Columbia Generating Station 19 2011 Radioactive Effluent Report Columbia Generating Station 19 2011 Radioactive Effluent Report

Co-58 1.69E-02 6.01 E+00 Mn-54 3.74E-03 1.33E+00 Nb-95 1.61 E-03 5.74E-01 Fe-55 1.39E-03 4.93E-01 Zr-95 1.01 E-03 3.60E-01 Sb-1 25 8.70E-04 3.09E-01 Ag-1i1m 4.90E-04 1.74E-01 Sb-124 3.20E-04 1.14E-01 Sr-89 2.44E-04 8.67E-02 H-3 4.96E-05 1.76E-02 C-14 1.78E-05 6.34E-03 Ra-226 1.08E-05 3.84E-03 Sr-90 7.40E-06 2.63E-03 Cm-242 6.02E-07 2.14E-04

3.

Solid Waste Disposition Number of Shipments Mode of TransDortation Destination 30 75*

Tractor - Trailer via Public Highway Tractor - Trailer via Public Highway Tractor - Trailer via Public Highway US Ecology, Inc.

P.O. Box 638 Hanford Reservation Richland, WA. 99352 Perma-Fix Northwest 2025 Battelle Blvd Richland, WA 99352 Perma-Fix of Fla 1940 N.W. 67th PI Gainesville, FL 32653 1

(* After processing, portions of these shipments will be forwarded for disposal.)

Irradiated Fuel Shipments (Disposition)

Number of Shipments None Mode of Transoortation Destination N/A N/A Columbia Generating Station 20 2011 Radioactive Effluent Report Columbia Generating Station 20 2011 Radioactive Effluent Report

5.0 Meteorological Data The meteorological data contained in Tables 5-1 through 5-11 was obtained from a meteorological tower located 762 meters (2500 feet) west of Columbia Generating Station. Data was recovered from two sets of redundant instruments on the tower at the 10 meter (33-foot) and 75 meter (245-foot) levels. The meteorological data is a composite file generated from the automated data recovery systems for the calendar year 2011. Data is archived on the Energy Northwest Local Area Network.

Meteorological data recovery for 2011 was 91.3% from both the 33-foot and the 245-foot levels. Redundant wind and temperature sensors are installed at both levels of the meteorological tower. Data from the two systems is mixed to permit maximum data recovery for defined date ranges.

The data in Tables 5-1 through 5-8 provide joint frequency distributions (JFD) at the 10-meter and 75-meter levels by quarter for 2011. These tables show the total hours at various wind speeds for each sector and stability class. The NRC stability classes A through G and eleven wind speed categories along with the 16 wind direction sectors were used to prepare each joint frequency table. Tables 5-9 and 5-10 provide the annual joint frequency distributions at the specified heights for 2011. Table 5-11 provides a joint frequency distribution from the 10 meter wind instruments during daylight hours of the growing season. The threshold value for daylight was chosen at solar irradiance of greater than 5 watts/m2. This JFD table was used for Carbon-14 (14C) dose estimates from ingestion pathways.

Wind speed is measured in miles per hour in the tables and speeds below 1.0 MPH were recorded as calms.

There are a number of atmospheric factors which affect dispersivity but which are not modeled in the CGS estimates of dispersion and deposition. Those conditions which were measured or documented at the Hanford Meteorological Station during 2011 were snow (3.1 inches total which fell in January, November and December),

total precipitation (4.45 inches), dust or blowing dust (2 day), fog (40 days), and thunderstorms (11 days).

Rainfall as recorded at the Columbia Generating Station meteorological tower was 2.96 inches.

Columbia Generating Station 21 2011 Radioactive Effluent Report Columbia Generating Station 21 2011 Radioactive Effluent Report

Joint Frequency Distribution Tables for 2011 Table 5-1 1st Quarter Average, 33 Ft Above Ground Level (AGL)

Hours at each wind speed and direction during time period Elevation:

33 Start Date:

1/1/2011 Total number of Periods: 2159 Period: 1st Quarter Stop Date:

4/1/2011 Periods of No Data Recovery:

8 System Percent Data Recovery: 99.6%

Stability Class:

A Wind Speed Min Max N

NNE NE ENE E

ESE SE SSE S

SSW SW WSW W

WNW NW NNW TOTAL 1.0 2.2 0

0 0

0 0

0 0

0 0

0 0

0 0

0 0

0 0

2.2 4.5 0

0 0

0 0

0 0

0 0

0 0

0 0

0 0

0 0

4.5 6.7 0

0 0

0 0

0 0

0 0

0 0

0 0

0 0

0 0

6.7 8.9 0

0

.0 0

0 0

0 0

0 0

0 0

0 0

0 0

0 8.9 11.2 0

0 0

0 0

0 0

0 0

0 0

0 0

0 0

0 0

11.2 13.4 1

0 0

0 0

0 0

-0 0

0 0

0 0

0 0

0 1

13.4 17.9 0

0 0

0 0

0 0

0 0

0 0

0 0

0 0

0 0

17.9 22.4 0

0 0

0 0

0 0

0 0

0 0

0 0

0 0

1 1

22.4 29.1 0

0 0

0 0

0 0

0 0

0 0

0 0

0 0

1 1

29.1 40.3 0

0 0

0 0

0 0

0 0

0 0

0 0

0 0

0 0

40.3 90.0 0

0 0

0 0

0 0

0 0

0 0

0 0

0 0

0 0

TOTALS 1

0 0

0 0

0 0

0 0

0 0

0 0

0 0

2 3

Stability Class:

B Wind Speed Min Max N

NNE NE ENE E

ESE SE SSE S

SSW SW WSW W

WNW NW NNW TOTAL 1.0 2.2 0

0 0

0 0

0 0

0 0

0 0

0 0

0 0

1 1

2.2 4.5 0

0 0

0 0

0 0

0 0

0 0

0 0

0 1

0 1

4.5 6.7 0

0 0

0 0

0 0

0 0

0 0

0 0

0 0

1 1

6.7 8.9 0

0 0

0 0

0 0

0 0

0 0

0 0

0 0

2 2

8.9 11.2 2

0 0

0 0

0 0

0 1

0 0

0 0

0 0

0 3

11.2 13.4 0

0 0

0 0

0 0

0 1

0 0

0 0

0 0

1 2

13.4 17.9 3

0 0

0 0

0 0

0 1

2 0

0 0

0 0

0 6

17.9 22.4 0

0 0

0 0

0 0

1 0

1 0

0 0

0 0

1 3

22.4 29.1 0

0 0

0 0

0 0

0 0

0 0

0 0

0 0

2 2

29.1 40.3 0

0 0

0 0

0 0

0 0

0 0

0 0

0 0

0 0

40.3 90.0 0

0 0

0 0

0 0

0 0

0 0

0 0

0 0

0 0

TOTALS 5

0 0

0 0

0 0

1 3

3 0

0 0

0 1

8 21 Stability Class:

C Wind Speed Min Max N

NNE NE ENE E

ESE SE SSE S

SSW SW WSW W

WNW NW NNW TOTAL 1.0 2.2 2

2 0

0 0

0 0

0 0

0 0

0 0

0 0

3 7

2.2 4.5 1

1 1

0 0

0 0

0 1

0 0

0 0

0 8

6 18 4.5 6.7 2

0 0

0 0

0 0

0 0

0 0

0 0

0 0

8 10 6.7 8.9 2

0 0

0 0

0 1

0 3

1 1

1 0

1 0

4 14 8.9 11.2 3

0 0

0 0

0 0

2

ý6 3

0 0

0 0

1 3

18 11.2 13.4 0

0 0

0 0

0 0

0 10 6

0 0

0 1

1 1

19 13.4 17.9 3

0 0

0 0

0 1

1 9

4 0

1 0

1 2

3 25 17.9 22.4 1

0 0

0 0

0 0

2 0

5 0

0 1

1 0

3 13 22.4 29.1 0

0 0

0 0

0 0

0 0

2 1

0 0

1 0

0 4

29.1 40.3 0

0 0

0 0

0 0

0 0

0 0

0 0

0 0

0 0

40.3 90.0 0

0 0

0 0

0 0

0 0

0 0

0 0

0 0

0 0

TOTALS 14 3

1 0

0 0

2 5

29 21 2

2 1

5 12 31 128 Stability Class:

D Wind Speed Min Max N

NNE NE ENE E

ESE SE SSE S

SSW SW WSW W

WNW NW NNW TOTAL 1.0 2.2 11 3

1 4

5 4

8 5

5 7

3 5

1 4

5 7

78 2.2 4.5 6

4 8

0 2

3 8

20 8

4 4

5 4

8 15 9

108 4.5 6.7 3

4 3

0 0

0 11 13 2

3 2

2 2

10 17 11 83 6.7 8.9 9

2 3

0 1

1 5

10 14 4

2 5

4 9

12 10 91 8.9 11.2 10 1

3 0

0 0

3 12 11 3

2 2

2 13 19 10 91 11.2 13.4 2

0 0

.0 0

0 3

5 13 9

2 1

1 5

5 6

52 13.4 17.9 2

1 0

0 0

0 1

8 22 13 5

4 0

5 3

3 67 17.9 22.4 0

0 0

0 0

0 1

1 5

13 4

2 3

3 0

0 32 22.4 29.1 0

0 0

0 0

0 0

0 0

12 5

0 0

0 0

0 17 29.1 40.3 0

0 0

0 0

0 0

0 0

3 2

0 0

0 0

0 5

40.3 90.0 0

0 0

0 0

0 0

0 0

0 0

0 0

0 0

0 0

TOTALS 43 15 18 4

8 8

40 74 80 71 31 26 17 57 76 56 624 CoubaGnrtn tto 221 aiatv fletRpr Columbia Generating Station 22 2011 Radioactive Effluent Report

Table 5-1 1st Quarter Average, 33 Ft AGL (Continued)

Stability Class:

E Wind Speed Min Max N

NNE NE ENE E

ESE SE SSE S

SSW SW WSW W

WNW NW NNW TOTAL 1.0 2.2 3

5 4

2 2

1 0

3 5

2 3

1 3

7 6

5 52 2.2 4.5 1

9 11 2

2 2

8 8

6 9

7 1

11 8

17 17 119 4.5 6.7 3

4 2

0 0

0 7

11 3

4 5

5 5

10 18 12 89 6.7 8.9 1

2 6

0 0

0 13 8

7 4

3 3

4 4

22 11 88 8.9 11.2 0

0 1

0 0

3 5

31 13 12 3

3 3

7 12 6

99 11.2 13.4 0

0 0

0 0

1 2

17 10 10 2

3 4

1 8

2 60 13.4 17.9 0

0 0

0 0

0 3

5 16 19 14 3

3 5

0 2

70 17.9 22.4 0

0 0

0 0

0 0

0 4

19 4

2 0

1 0

0 30 22.4 29.1 0

0 0

0 0

0 0

0 1

13 1

0 0

0 0

0 15 29.1 40.3 0

0 0

0 0

0 0

0 0

1 0

0 0

0 0

0 1

40.3 90.0 0

0 0

0 0

0 0

0 0

0 0

0 0

0 0

0 0

TOTALS 8

20 24 4

4 7

38 83 65 93 42 21 33 43 83 55 623 Stability Class:

F Wind Speed Min Max N

NNE NE ENE E

ESE SE SSE S

SSW SW WSW W

WNW NW NNW TOTAL 1.0 2.2 5

7 2

4 1

1 1

1 5

5 4

3 4

5 8

6 62 2.2 4.5 8

15 7

3 0

3 5

11 12 9

4 3

3 14 23 16 136 4.5 6.7 4

2 4

1 0

0 4

11 8

10 7

3 2

8 24 4

92 6.7 8.9 0

0 4

0 0

0 3

16 11 8

1 2

1 6

15 1

68 8.9 11.2 0

  • 0 2

0 0

0 1

20 10 3

4 2

3 3

4 0

52 11.2 13.4 0

0 0

0 0

0 1

9 4

5 1

0 1

0 0

0 21 13.4 17.9 0

0 0

0 0

0 1

0 5

7 0

0 0

0 0

0 13 17.9 22.4 0

0 0

0 0

0 0

0 0

2 0

0 0

0 0

0 2

22.4 29.1 0

0 0

0 0

0 0

0 0

0 0

0 0

0 0

0 0

29.1 40.3 0

0 0

0 0

0 0

0 0

0 0

0 0

0 0

0 0

40.3 90.0 0

0 0

0 0

0 0

0 0

0 0

0 0

0 0

0 0

TOTALS 17 24 19 8

1 4

16 68 55 49 21 13 14 36 74 27 446 Stability Class:

G

  • Wind Speed Min Max N

NNE NE ENE E

ESE SE SSE S

SSW SW WSW W

WNW NW NNW TOTAL 1.0 2.2 6

0 0

0 0

0 0

0 1

3 0

3 2

3 6

9 33 2.2 4.5 4

4 0

0 1

0 1

3 1

4 5

4 2

4 16 8

57 4.5 6.7 0

0 2

0 0

0 1

4 2

4 1

2 0

1 12 5

34

'6.7 8.9 0

0 1

0 0

0 2

5 3

0 0

0 0

0 5

0 16 8,9 11.2 0

0 0

0 0

0 0

3 1

0 0

0 0

0 0

0 4

11.2 13.4 0

0 1

0 0

0 0

5 0

0 0

0 0

0 0

0 6

13.4 17.9 0

0 0

0 0

0 0

3 0

1 0

0 0

0 0

0 4

17.9 22.4 0

0 0

0 0

0 0

0 0

0 0

0 0

0 0

0 0

22.4 29.1 0

0 0

0 0

0 0

0 0

0 0

0 0

0 0

0 0

29.1 40.3 0

0 0

0 0

0 0

0 0

0 0

0 0

0 0

0 0

40.3 90.0 0

0 0

0 0

0 0

0 0

0 0

0 0

0 0

0 0

TOTALS 10 4

4 0

1 0

4 23 8

12 6

9 4

8 39 22 154 Stability Class:

All Wind Speed Min Max N

NNE NE ENE E

ESE SE SSE S

SSW SW WSW W

WNW NW NNW TOTAL 1.0 2.2 27 17 7

10 8

6 9

9 16 17 10 12 10 19 25 31 233 2.2 4.5 20 33 27 5

5 8

22 42 28 26 20 13 20 34 80 56 439 4.5 6.7 12 10 11 1

0 0

23 39 15 21 15 12 9

29 71 41 309 6.7 8.9 12 4

14 0

1 1

24 39 38 17 7

11 9

20 54 28 279 8.9 11.2 15 1

6 0

0 3

9 68 42 21 9

7 8

23 36 19 267 11.2 13.4 3

0 1

0 0

1 6

36 38 30 5

4 6

7 14 10 161 13.4 17.9 8

1 0

0 0

0 6

17 53 46 19 8

3 11 5

8 185 17.9 22.4 1

0 0

0 0

0 1

4 9

40 8

4 4

5 0

5 81 22.4 29.1 0

0 0

0 0

0 0

0 1

27 7

0 0

1 0

3 39 29.1 40.3 0

0 0

0 0

0 0

0 0

4 2

0 0

0 0

0 6

40.3 90.0 0

0 0

0 0

0 0

0 0

0 0

0 0

0 0

0 0

TOTALS 98 66 66 16 14 19 100 254 240 249 102 71 69 149 285 201 1999 Periods of Calm while in Stability Class:

A B

C D

E F

G Total 0

4 50 40 43 15 152 CoubaGneaigSaio 321 adocieEfletRpr Columbia Generating Station 23 2011 Radioactive Effluent Report

Table 5-2 1st Quarter Average, 245 Ft AGL Hours at each wind speed and direction during time period Elevation:

245 Start Date:

1/1/2011 Total number of Periods: 2159 Period: 1st Quarter Stop Date:

4/1/2011 Periods of No Data Recovery:

8 System Percent Data Recovery: 99.6%

Stability Class: -A Wind Speed Min Max N

NNE NE ENE E

ESE SE SSE S

SSW SW WSW W

WNW NW NNW TOTAL 1.0 2.2 0

0 0

0 0

0 0

0 0

0 0

0 0

0 0

0 0

2.2 4.5 0

0 0

0 0

0 0

0 0

0 0

0 0

0 0

0 0

4.5 6.7 0

0 0

0 0

0 0

0 0

0 0

0 0

0 0

0 0

6.7 8.9 0

0 0

0 0

0 0

0 0

0 0

0 0

0 0

0 0

8.9 11.2 0

0 0

0 0

0 0

0 0

0 0

0 0

0 0

0 0

11.2 13.4 0

0 0

0 0

0 0

0 0

0 0

0 0

0 0

0 0

13.4 17.9 1

0 0

0 0

0 0

0 0

0 0

0ý 0

0 0

0 1

17.9 22.4 0

0 0

0 0

0 0

0 0

0 0

0 0

0 0

0 0

22.4 29.1 2

0 0

0 0

0 0

0 0

0 0

0 0

0 0

0 2

29.1 40.3 0

0 0

0 0

0 0

0 0

0 0

0 0

0 0

0 0

40.3 90.0 0

0 0

0 0

0 0

0 0

0 0

0 0

0 0

0 0

TOTALS 3

0 0

0 0

0 0

0 0

0 0

0 0

0 0

0 3

Stability Class:

B Wind Speed Min Max N

NNE NE ENE E

ESE SE SSE S

SSW SW WSW W

WNW NW NNW TOTAL 1.0 2.2 0

0 0

0 0

0 0

0 0

0 0

0 0

0 0

0 0

2.2 4.5 1

0 0

0 0

0 0

0 0

0 0

0 0

0 0

1 2

4.5 6.7 0

0 0

0 0

0 0

0 0

0 0

0 0

0 0

1 1

6.7 8.9 0

0 0

0 0

0 0

0 0

0 0

0 0

0 0

1 1

8.9 11.2 2

0 0

0 0

0 0

0 1

0 0

0 0

0 0

1 4

11.2 13.4 0

0 0

0 0

0 0

0 0

0 0

0 0

0 0

0 0

13.4 17.9 1

3 0

0 0

0 0

0 0

3 0

0 0

0 0

0 7

17.9 22.4 0

.0 0

0 0

0 0

0 1

2 0

0 0

0 0

0 3

22.4 29.1 1

0 0

0 0

0 0

0 0

0 0

0 0

0 0

2 3

29.1 40.3 0

0 0

0 0

0 0

0 0

0 0

0 0

0 0

0 0

40.3 90.0 0

0 0

0 0

0 0

0 0

0 0

0 0

0 0

0 0

TOTALS 5

3 0

0 0

0 0

0 2

5 0

0 0

0 0

6 21 Stability Class:

C Wind Speed Min Max N

NNE NE ENE E

ESE SE SSE S

SSW SW WSW W

WNW NW NNW TOTAL 1.0 2.2 1

1 1

0 0

0 0

0 0

0 0

0 0

0 1

2 6

2.2 4.5 1

1 1

0 0

0 0

0 0

0 0

0 0

0 7

7 17 4.5 6.7 2

0 0

0 0

0 0

0 1

0 0

0 0

0 1

5 9

6.7 8.9 2

0 0

0 0

0 0

1 1

0 0

0 0

0 0

6 10 8.9 11.2 1

0 0

0 0

0 0

1 3

2 2

1 0

1 1

2 14 11.2 13.4 1

0 0

0 0

0 0

0 4

4 0

0 0

0 1

3 13 13.4 17.9 1

1 0

0 0

0 1

0 8

13 1

0 0

2 1

2 30 17.9 22.4 3

0 0

0 0

0 0

0 3

4 1

0 2

0 1

1 15 22.4 29.1 0

0 0

0 0

0 0

0 2

3 2

0 0

2 0

3 12 29.1 40.3 0

0 0

0 0

0 0

0 0

1 1

0 0

0 0

0 2

40.3 90.0 0

0 0

0 0

0 0

0 0

0 0

0 0

0 0

0 0

TOTALS 12 3

2 0

0 0

1 2

22 27 7

1 2

5 13 31 128 Stability Class:

D Wind Speed Min Max N

NNE NE ENE E

ESE SE SSE S

SSW SW WSW W

WNW NW NNW TOTAL 1.0 2.2 4

6 5

2 4

2 4

4 5

7 4

4 2

7 4

4 68 2.2 4.5 8

5 6

3 2

5 7

13 7

3 4

1 2

6 7

11 90 4.5 6.7 3

5 5

1 0

1 5

16 6

4 5

4 3

5 10 16 89 6.7 8.9 2

4 2

0 0

0 4

5 9

3 2

1 3

2 16 7

60 8.9 11.2 10 1

0 1

1 1

2 12 7

12 0

6 3

8 9

4 77 11.2 13.4 11 0

4 0

0 0

0 4

6 4

2 2

1 6

14 10 64 13.4 17.9 5

0 0

0 0

0 2

4 22 19 7

1 1

15 8

10 94 17.9 22.4 0

3 0

0 0

0 0

2 6

16 6

2 2

2 3

4 46 22.4 29.1 0

0 0

0 0

0 0

3 2

20 6

2 3

2 0

0 38 29.1 40.3 0

0 0

0 0

0 0

0 0

10 12 0

0 2

0 0

24 40.3 90.0 0

0 0

0 0

0 0

0 0

0 0

0 0

0 0

0 0

TOTALS 43 24 22 7

7 9

24 63 70 98 48 23 20 55 71 66 650 Columbia Generating Station 24 2011 Radioactive Effluent Report

Table 5-2 1st Quarter Average, 245 Ft AGL (Continued)

Stability Class:

E Wind Speed Min Max N

NNE NE ENE E

ESE SE SSE S

SSW SW WSW W

WNW NW NNW TOTAL 1.0 2.2 2

2 3

1 2

2 3

4 1

5 1

1 0

1 2

1 31 2.2 4.5 7

6 11 6

6 5

4 5

6 2

3 2

2 6

8 3

82 4.5 6.7 11 6

6 0

1 2

3 1

5 2

1 4

8 4

4 9

67 6.7 8.9 2

1 5

2 0

0 5

8 2

3 2

2 0

3 6

7 48 8.9 11.2 4

1 5

0 0

1 5

9 3

5 4

0 8

5 7

13 70 11.2 13.4 3

0 4

0 0

0 4

6 8

7 2

1 1

4 6

16 62 13.4 17.9 3

0 0

1 1

1 5

8 29 20 6

4 4

9 6

22 119 17.9 22.4 1

0 0

0 0

0 1

3 16 21 13 5

3 10 5

5 83 22.4 29.1 2

0 0

0 0

0 0

0 5

20 16 7

1 6

1 1

59 29.1 40.3 0

0 0

0 0

0 0

0 0

19 12 2

0 1

0 0

34 40.3 90.0 0

0 0

0 0

0 0

0 0

1 0

0 0

0 0

0 1

TOTALS 35 16 34 10 10 11 30 44 75 105 60 28 27 49 45 77 656 Stability Class:

F Wind Speed Min Max N

NNE NE ENE E

ESE SE SSE S

SSW SW WSW W

WNW NW NNW TOTAL 1.0 2.2 2

2 4

3 3

5 2

4 3

2 4

1 0

4 1

3 43 2.2 4.5 4

3 6

7 4

4 9

3 2

6 6

6 3

2 8

11 84 4.5 6.7 11 12 5

3 1

4 5

11 4

0 4

1 1

6 10 11 89 6.7 8.9 4

4 2

3 0

0 3

5 7

1 2

4 2

3 5

4 49 8.9 11.2 2

1 3

1 0

1 4

8 5

6 4

1 0

3 4

5 48 11.2 13.4 0

0 2

1 1

0 3

4 4

8 3

0 2

1 7

4 40 13.4 17.9 1

0 0

1 0

0 0

9 14 13 4

4 4

8 9

10 77 17.9 22.4 0

0 0

0 0

0 0

1 6

12 7

2 0

6 0

1 35 22.4 29.1 0

0 0

0 0

0 0

0 3

2 2

0 0

1 0

0 8

29.1 40.3 0

0 0

0 0

0 0

0 0

6 1

0 0

0 0

0 7

40.3 90.0 0

0 0

0 0

0 0

0 0

0 0

0 0

0 0

0 0

TOTALS 24 22 22 19 9

14 26 45 48 56 37 19 12 34 44 49 480 Stability Class:

G Wind Speed Min Max N

NNE NE ENE E

ESE SE SSE S

SSW SW WSW W

WNW NW NNW TOTAL 1.0 2.2 1

0 2

0 2

0 0

3 0

1 0

1 1

2 0

2 15 2.2 4.5 4

3 3

2 1

2 2

2 2

2 1

3 1

2 2

4 36 4.5 6.7 5

2 2

1 1

1 3

3 3

0 2

0 1

1 2

2 29

'6.7 8.9 2

4 2

0 0

0 2

1 2

5 2

3 0

1 1

5 30 8.9 11.2 2

0 1

1 0

0 2

2 0

3 2

1 0

1 3

4 22 11.2 13.4 0

0 0

0 0

0 2

2 0

2 1

0 0

0 1

3 11 13.4 17.9 0

0 0

0 0

0 1

4 4

2 0

0 2

3 1

0 17 17.9 22.4 0

0 0

0 0

0 0

0 2

0 0

0 0

0 0

0 2

22.4 29.1 0

0 0

0 0

0 0

0 1

2 0

0 0

0 0

0 3

29.1 40.3 0

0 0

0 0

0 0

0 0

0 0

0 0

0 0

0 0

40.3 90.0 0

0 0

0 0

0 0

0 0

0 0

0 0

0 0

0 0

TOTALS 14 9

10 4

4 3

12 17 14 17 8

8 5

10 10 20 165 Stability Class:

All Wind Speed Min Max N

NNE NE ENE E

ESE SE SSE S

SSW SW WSW W

WNW NW NNW TOTAL 1.0 2.2 10 11 15 6

11 9

9 15 9

15 9

7 3

14 8

12 163 2.2 4.5 25 18 27 18 13 16 22 23 17 13 14 12 8

16 32 37 311 4.5 6.7 32 25 18 5

3 8

16 31 19 6

12 9

13 16 27 44 284 6.7 8.9 12 13 11 5

0 0

14 20 21 12 8

10 5

9 28 30 198 8,9 11.2 21 3

9 3

1 3

13 32 19 28 12 9

11 18 24 29 235 11.2 13.4 15 0

10 1

1 0

9 16 22 25 8

3 4

11 29 36 190 13.4 17.9 12 4

0 2

1 1

9 25 77 70 18 9

11 37 25 44 345 17.9 22.4 4

3 0

0 0

0 1

6 34 55 27 9

7 18 9

11 184 22.4 29.1 5

0 0

0 0

0 0

3 13 47 26 9

4 11 1

6 125 29.1 40.3 0

0 0

0 0

0 0

0 0

36 26 2

0 3

0 0

  • 67 40.3 90.0 0

0 0

0 0

0 0

0 0

1 0

0' 0

0 0

0 1

TOTALS 136 77 90 40 30 37 93 171 231 308 160 79 66 153 183 249 2103 Periods of Calm while in Stability Class:

I A

B C

D E

F G

Total 0

0 4

24 7

9 4

48 Columbia Generating Station 25 2011 Radioactive Effluent Report Columbia Generating Station 25, 2011 Radioactive Effluent Report

Table 5-3 2nd Quarter Average, 33 Ft AGL Hours at each wind speed and direction durinq time perod Elevation:

33 Start Date:

4/1/2011 Total number of Periods: 2184 Period: 2nd Quarter Stop Date:

7/1/2011 Periods of No Data Recovery:

339 System Percent Data Recovery: 84.5%

Stability Class:

A Wind Speed Min Max N

NNE NE ENE E

ESE SE SSE S

SSW SW WSW W

WNW NW NNW TOTAL 1.0 2.2 0

0 0

0 0

0 0

0 0

0 0

0 0

0 0

0 0

2.2 4.5 0

1 0

0 0

0 0

0 0

0 0

0 0

0 0

0 i

4.5 6.7 0

1 0

0 0

0 0

0 0

0 0

0 0

0 1

2 4

6.7 8.9 1

6 0

0 0

0 0

0 1

0 0

0 1

0 0

0 9

8.9 11.2 2

3 0

0 0

0 0

2 0

0 0

1 1

0 0

3 12 11.2 13.4 1

0 0

0 0

0 0

1 2

0 0

1 0

0 0

0 5

13.4 17.9 6

0 0

0 0

0 0

3 7

3 2

0 1

1 0

1 24 17.9 22.4 0

0 0

0 0

0 0

0 3

1 5

3 1

0 1

0 14.

22.4 29.1 0

0 0

0 0

0 0

0 0

0 0

0 0

0 0

0 0

29.1 40.3 0

0 0

0 0

0 0

0 0

0 0

0 0

0 0

0 0

40.3 90.0 0

0 0

0 0

0 0

0 0

0 0

0 0

0 0

0 0

TOTALS 10 11 0

0 0

0 0

6 13 4

7 5

4 1

2 6

69 Stability Class:

B Wind Speed Min Max N

NNE NE ENE E

ESE SE SSE S

SSW SW WSW W

WNW NW NNW TOTAL 1.0 2.2 0

0 0

0 0

0 0

0 0

0 0

0 0

0 0

0 0

2.2 4.5 3

2 1

1 0

1 0

1 0

0 0

0 0

0 2

2 13 4.5 6.7 2

1 0

0 1

2 1

1 1

0 3

2 0

1 2

2 19 6.7 8.9 2

1 0

0 1

1 2

3 3

1 2

0 1

0 0

1 18 8.9 11.2 4

2 1

0 0

0 1

1 3

2 1

1 1

0 1

1 19 11.2 13.4 1

0 0

0 0

0 0

3 10 2

0 1

0 0

1 0

18 13.4 17.9 1

0 0

0 0

0 1

1 5

1 3

2 1

2 0

1 18 17.9 22.4 0

0 0

0 0

0 0

0 0

6 4

2 1

3 0

0 16 22,4 29.1 0

0 0

0 0

0 0

0 1

1 0

0 0

1 1

0 4

29.1 40.3 0

0 0

0 0

0 0

0 0

0 0

0 0

0 0

0 0

40.3 90.0 0

0 0

0 0

0 0

0 0

0 0

0 0

0 0

0 0

TOTALS 13 6

2 1

2 4

5 10 23 13 13 8

4 7

7 7

125 Stability Class:

C Wind Speed Min Max N

NNE NE ENE E

ESE SE SSE S

SSW SW WSW W

WNW NW NNW TOTAL 1.0 2.2 1

0 2

0 1

0 1

1 0

0 0

2 0

1 1

0 10 2.2 4.5 5

3 5

10 5

4 3

4 4

1 2

6 2

2 4

5 65 4.5 6.7 2

0 2

2 0

0 7

7 8

5 4

8 3

1 1

4 54 6.7

.8.9 3

2 1

3 2

2 4

9 12 1

4 4

2 3

1 1

54 8.9 11.2 0

0 0

0 0

1 0

2 7

4 1

4 1

5 1

5 31 11.2 13.4 2

0 0

0 0

0 0

3 6

5 1

1 5

2 1

0 26 13.4 17.9 0

0 0

0 0

0 0

2 10 12 3

7 3

6 2

0 45 17.9 22.4 0

0 0

0 0

0 0

0 2

3 4

3 2

1 1

0 16 22.4 29.1 0

0 0

0 0

0 0

0 0

0 0

0 0

2 0

0 2

29.1 40.3 0

0 0

0 0

0 0

0 0

0 0

0 0

0 0

0 0

40.3 90.0 0

0 0

0 0

0 0

0 0

0 0

0 0

0 0

0 0

TOTALS 13 5

10 15 8

7 15 28 49 31 19 35 18 23 12 15 303 Stability Class:

D Wind Speed Min Max N

NNE NE ENE E

ESE SE SSE S

SSW SW WSW W

WNW NW NNW TOTAL 1.0 2.2 2

2.2 4.5 3

4.5 6.7 1

6.7 8.9 1

8.9 11.2 1

11.2 13.4 1

13.4 17.9 0

17.9 22.4 0

22.4 29.1 0

29.1 40.3 0

40.3 90.0 n

1 3

6 3

3 2

2 1

0 0

0 0

0 0

0 0

0 0

0 0

n n3 2

7 4

1 0

0 0

0 0

0n 4

9 3

3 0

0 0

0 0

0 4

6 4

2 1

2 1

10 14 12 4

9 4

3 6

7 11 10 2

2 4

7 7

11 6

4 4

3 0

4 6

9 5

2 2

0 2

3 8

4 3

3 0

0 7

5 15 12 4

0 0

1 1

9 6

4

0.

0 0

0 0

0 0

0 0

0 0

0.

0 0

0 n

0 0

0 0

0 0

1 1

1 0

2 4

7 3

5 7

6 2

5 2

3 5

7 6

4 4

10 4

1 8

23 5

2 4

16 1

0 0

2 0

0 0

0 0

0 0

0 0

0 35 97 76 62 51 43 81 42 2

0 0

403 900 0

0 0

0 0

TOTALS 9

12 9

14 19 27 40 55 45 49 35 24 26 1

30 24 489 Columbia Generating Station 26 2011 Radioactive Effluent Report Columbia Generating Station 26 2011 Radioactive Effluent Report

Table 5-3 2nd Quarter Average, 33 Ft AGL (Continued)

.Stability Class:

E Wind Speed Min Max N

NNE NE ENE E

ESE SE SSE S

SSW SW WSW W

WNW NW NNW TOTAL 1.0 2.2 2

2 2

3 0

3 1

1 3

6 2

3 1

3 2

2 36 2.2 4.5 6

3 1

1 1

4 5

12 9

5 2

4 4

7 8

4 76 4.5 6.7 2

2 3

2 3

6 7

3 7

5 11 8

6 11 13 6

95 6.7 8.9 1

1 1

0 0

0 5

9 5

3 8

4 7

15 4

2 65 8.9 11.2 0

0 0

0 0

0 1

5 4

3 5

3 9

24 9

1 64 11.2 13.4 0

0 1

0 0

0 2

3 2

10 0

4 6

23 1

1 53 13.4 17.9 0

0 0

0 0

0 0

0 1

9 6

2 1

13 3

0 35 17.9 22.4 0

0 0

0 0

0 0

0 0

1 1

0 2

2 0

0 6

22.4 29.1 0

0 0

0 0

0 0

0 0

1 0

0 0

0 0

0 1

29.1 40.3 0

0 0

0 0

0 0

0 0

0 0

0 0

0 0

0 0

40.3 90.0 0

0 0

0 0

0 0

0 0

0 0

0 0

0 0

0 0

TOTALS 11 8

8 6

4 13 21 33 31 43 35 28 36 98 40 16 431 Stability Class:

F Wind Speed Min Max N

NNE NE ENE E

ESE SE SSE S

SSW SW WSW W

WNW NW NNW TOTAL 1.0 2.2 0

5 1

0 3

1 3

3 2-2 1

0 2

0 3

5 31 2.2 4.5 2

8 7

0 0

1 18 11 5

3 0

5 2

5 8

5 80 4.5 6.7 2

0 3

0 0

0 14 23 3

5 5

2 3

6 9

4 79 6.7 8.9 0

1 0

0 0

0 4

10 4

3 4

0 1

7 3

2 39 8.9 11.2 0

0 0

0 0

0 0

1 1

2 0

0 3

6 3

0 16 11.2 13.4 0

0 0

0 0

0 0

0 0

1 0

0 1

1 1

0 4

13.4 17.9 0

0 0

0 0

0 0

0 0

1 0

0 0

0 0

0 1

17.9 22.4 0

0 0

0 0

0 0

0 0

0 0

0 0

0 0

0 0

22.4 29.1 0

0 0

0 0

0 0

0 0

0 0

0 0

0 0

0 0

29.1 40.3 0

0 0

0 0

0 0

0 0

0 0

0 0

0 0

0 0

40.3 90.0 0

0 0

0 0

0 0

0 0

0 0

0 0

0 0

0 0

TOTALS 4

14 11 0

3 2

39 48 15 17 10 7

12 25 27 16 250 Stability Class:

G Wind Speed Min Max N

NNE NE ENE E

ESE SE SSE S

SSW SW WSW W

WNW NW NNW TOTAL 1.0 2.2 2

3 2

0 1

0 1

1 0

1 0

0 1

2 1

1 16 2.2 4.5 7

5 1

0 0

0 8

9 2

0 0

2 0

0 9

3 46 4.5 6.7 1

2 3

0 0

0 10 15 3

1 0

0 0

2 4

3 44 6.7 8.9 0

0 0

0 0

0 2

1 0

1 0

0 0

2 3

1 10 8.9 11.2 0

0 0

0 0

0 0

0 0

1 0

0 0

0 0

0 1

11.2 13.4 0

0 0

0 0

"0 0

0 0

0 0

0 0

0 0

0 0

13.4 17.9 0

0 0

0 0

0 0

0 0

0 0

0 0

0 0

0 0

17.9 22.4 0

0 0

0 0

0 0

0 0

0 0

0 0

0 0

0 0

22.4 29.1 0

0 0

0 0

0 0

0 0

0 0

0 0

0 0

0 0

29.1 40.3 0

0 0

0 0

0 0

0 0

0 0

0 0

0 0

0 0

40.3 90.0 0

0 0

0 0

0 0

0 0

0 0

0 0

0 0

0 0

TOTALS 10 10 6

0 1

0 21 26 5

4 0

2 1

6 17 8

117 Stability Class:

All Wind Speed Min Max N

NNE NE ENE E

ESE SE SSE S

SSW SW WSW W

WNW NW NNW TOTAL 1.0 2.2 7

11 10 5

9 8

12 10 7

10 5

6 4

7 8

9 128 2.2 4.5 26 28 18 19 15 20 48 49 24 18 8

20 8

16 35 26 378 4.5 6.7 10 9

13 8

7 14 46 60 32 18 25 24 15 26 37 27 371 6.7 8.9 8

13 3

4 6

10 24 43 31 13.22 11 14 32 13 10 257 8.9 11.2 7

5 1

0 0

1 6

17 24 17 9

11 20 42 20 14 194 11.2 13.4 5

0 1

0 0

0 4

13 28 22 4

10 16 36 8

2 149 13.4 17.9 7

0 0

0 0

0 1

13 28 41 26 15 14 45 10 4

204 17.9 22.4 0

0 0

0 0

0 0

1 6

20 20 12 10 22 3

0 94 22.4 29.1 0

0 0

0 0

0 0

0 1

2 0

0 0

5 1

0 9

29.1 40.3 0

0 0

0 0

0 0

0 0

0 0

0 0

0 0

0 0

40.3 90.0 0

0 0

0 0

0 0

0 0

0 0

0 0

0 0

0 0

TOTALS 70 66 46 36 37 53 141 206 181 161 119 109 101 231 135 92 1784 Perods of Calm while in Stability Class:

I A

B C

D E

F G

Total 0

1 5

13 18 15 9

61 1 Columbia Generating Station 27 2011 Radioactive Effluent Report

Table 5-4 2nd Quarter Average, 245 Ft AGL Hours at each wind speed and direction during time period Elevation:

245 Start Date:

4/1/2011 Total number of Periods: 2184 Period: 2nd Quarter Stop Date:

7/1/2011 Periods of No Data Recovery: 339 System Percent Data Recovery: 84.5%

Stability Class:

A Wind Speed Min Max N

NNE NE ENE E

ESE SE SSE S

SSW SW WSW W

WNW NW NNW TOTAL 1.0 2.2 0

0 0

0 0

0 0

0 0

0 0

0 0

0 0

0 0

2.2 4.5 0

1 0

0 0

0 0

0 0

0 0

0 0

0 0

0 1

4.5 6.7 0

0 0

0 0

0 0

0 0

0 0

0 0

0 0

1 1

6.7 8.9 0

2 0

0 0

0 0

0 0

0 0

0 1

0 1

1 5

8.9 11.2 2

5 1

0 0

0 0

0 0

1 0

0 0

0 0

3 12 11.2 13.4 2

2 0

0 0

0 0

2 1

0 0

1 1

0 0

0 9

13.4 17.9 6

0 0

0 0

0 0

0 5

0 0

1 0

0 0

0 12 17.9 22.4 0

0 0

0 0

0 0

0 6

6 1

1 0

2 0

2 18 22.4 29.1 0

0 0

0 0

0 0

0 0

2 5

3 1

0 0

0 11 29.1 40.3 0

0 0

0 0

0 0

0 0

0 0

0 0

0 0

0 0

40.3 90.0 0

0 0

0 0

0 0

0 0

0 0

0 0

0 0

0 0

TOTALS 10 10 1

0 0

0 0

2 12 9.

6 6

3

2.

1 7

69 Stability Class:

B Wind Speed Min Max N

NNE NE ENE E

ESE SE SSE S

SSW SW WSW W

WNW NW NNW TOTAL 1.0 2.2 0

0 0

0 0

0 0

0 0

0 0

0 0

0 0

1 1

2.2 4.5 1

1 0

2 0

0 0

1 0

0 0

0 0

0 1

2 8

4.5 6.7 4

2 0

0 0

1 0

1 0

1

.0 0

0 0

2 1

12 6.7 8.9 2

1 0

0 0

2 2

0 4

0 0

3 2

0 1

1 18 8.9 11.2 2

3 1

0 1

1 1

0 4

1 2

0 1

0 0

2 19 11.2 13.4 1

0 0

0 0

1 1

2 1

2 1

1 0

1 1

0 12 13.4 17.9 2

0 0

0 0

0 0

1 12 6

2 1

0 0

0 2

26 17.9 22.4 0

0 0

0 0

0 0

0 1

1 5

1 2

2 0

0 12 22.4 29.1 0

0 0

0 0

0 0

0 0

4 6

1 2

4 1

0 18 29.1 40.3 0

0 0

0 0

0 0

0 0

0 0

0 0

0 0

0 0

40.3 90.0 0

0 0

0 0

0 0

0 0

0 0

0 0

0 0

0 0

TOTALS 12 7

1 2

1 5

4 5

22 15 16 7

7 7

6 9

126 Stability Class:

C Wind Speed Min Max N

NNE NE ENE E

ESE SE SSE S

SSW SW WSW W

WNW NW NNW TOTAL 1.0 2.2 0

1 0

0 0

0 0

1 1

0 0

0 1

2 0

0 6

2.2 4.5 3

3 3

4 5

3 0

2 4

2 0

5 5

1 2

2 44 4.5 6.7 3

1 0

3 6

4 5

1 2

7 3

4 1

2 4

1 47 6.7 8.9 2

1 1

4 1

0 3

9 9

3 5

5 3

0 1

3 50 8.9 11.2 3

1 0

2 0

2 3

1 11 4

1 3

5 4

0 4

44 11.2 13.4 0

0 0

0 0

3 0

1 8

2 2

3 2

2 1

1 25 13.4 17.9 1

1 0

0 0

0 0

2 8

12 6

2 7

5 1

0 45 17.9 22.4 0

0 0

0 0

0 0

0 4

8 2

5 3

3 2

1 28 22.4 29.1 0

0 0

0 0

0 0

0 1

2 4

2 3

2 1

0 15 29.1 40.3 0

0 0

0 0

0 0

0 0

0 0

0 0

1 0

0 1

40.3 90.0 0

0 0

0 0

0 0

0 0

0

.0 0

0 0

0 0

0 TOTALS 12 8

4 13 12 12 11 17 48 40 23 29 30 22 12 12 305 Stability Class:

D Wind Speed Min Max N

NNE NE ENE E

ESE SE SSE S

SSW. SW WSW W

WNW NW NNW TOTAL 1.0 2.2 2

1 3

2 2

3 1

1 2

1 1

1 0

0 1

1 22 2.2 4.5 2

3 2

2 5

6 16 8

5 3

6 3

2 3

3 6

75 4.5 6.7 3

2 2

6 7

5 6

10 3

7 3

1 4

3 3

3 68 6.7 8.9 2

1 1

2 2

3 7

8 13 2

2 2

2 4

6 2

59 8.9 11.2 1

1 1

0 1

3 3

4 7

5 2

3 0

3 3

5 42 11.2 13.4 1

0 0

0 0

6.

5 0

2 6

2 4

3 2

2 4

37 13.4 17.9 0

2 0

0 0

1 3

5 9

16 5

4 10 11 4

3 73 17.9 22.4 0

0 0

0 0

0 0

0 6

13 6

3 5

18 6

1 58 22.4 29.1 0

0 0

0 0

0 0

0 2

4 10 8

4 21 7

0 56 29.1 40.3 0

0 0

0 0

0 0

0 0

0 0

1 0

4 0

0 5

40.3 90.0 0

0 0

0 0

0 0

0 0

0 0

0 0

0 0

0 0

TOTALS 11 10 9

12 17 27 41 36 49 57 37 30 30 69 35 25 495 Columbia Generating Station 28 2011 Radioactive Effluent Report Columbia Generating Station 28 2011 Radioactive Effluent Report

Table 5-4 2nd Quarter Average, 245 Ft AGL (Continued)

Stability Class:

E Wind Speed Min Max N

NNE NE ENE E

ESE SE SSE S

SSW SW WSW W

WNW NW NNW TOTAL 1.0 2.2 1

0 1

2 1

0 1

0 0

1 2

0 0

2 0

0 11 2.2 4.5 3

1 2

2 2

2 1

1 3

2 1

3 5

5 4

2 39 4.5 6.7 0

1 0

3 0

1 3

2 2

1 6

7 4

1 3

4 38 6.7 8.9 4

2 1

0 0

2 4

2 2

3 5

4 7

9 5

1 51 8.9 11.2 1

2 2

3 1

2 3

0 4

2 2

7 6

9 8

1 53 11.2 13.4 2

1 1

0 0

0 1

1 7

3 6

2 6

11 5

0 46 13.4 17.9 1

0 0

1 1

2 2

1 9

9 10 8

7 20 12 6

89 17.9 22.4 0

0 0

0 0

0 0

1 1

7 8

2 2

42 10 1

74 22.4 29.1 0

0 0

0 0

0 0

0 1

4 3

3 1

25 4

0 41 29.1 40.3 0

0 0

0 0

0 0

0 0

0 2

0 1

1 0

0 4

40.3 90.0 0

0 0

0 0

0 0

0 0

0 0

0 0

0 0

0 0

TOTALS 12 7

7 11 5

9 15 8

29 32 45 36 39 125 51 15 446 Stability Class:

F Wind Speed Min Max N

NNE NE ENE E

ESE SE SSE S

SSW SW WSW W

WNW NW NNW TOTAL 1.0 2.2 1

0 0

0 1

2 1

0 3

3 2

0 0

0 0

1 14 2.2 4.5 4

1 0

2 0

1 3

2 7

3 6

3 3

1 3

1 40 4.5 6.7 3

2 0

2 0

2 2

3 4

6 2

3 2

2 2

1 36 6.7 8.9 0

1 2

3 0

2 1

6 1

1 3

6 2

4 1

5 38 8.9 11.2 2

3 4

0 0

1 0

5 10 3

2 2

4 1

4 2

43 11.2 13.4 0

0 2

2 0

0 2

1 6

4 5

2 1

4 1

2 32 13.4 17.9 1

0 0

0 0

0 0

0 3

4 2

0 1

13 11 0

35 17.9 22.4 0

0 0

0 0

0 0

0 0

0 2

0 2

9 4

1 18 22.4 29.1 0

0 0

0 0

0 0

0 0

0 0

0 1

1 0

0 2

29.1 40.3 0

0 0

0 0

0 0

0 0

0 0

0 0

0 0

0 0

40.3 90.0 0

0 0

0 0

0 0

0 0

0 0

0 0

0 0

0 0

TOTALS 11 7

8 9

1 8

9 17 34 24 24 16 16 35 26 13 258 Stability Class:

G Wind Speed Min Max N

NNE NE ENE E

ESE SE SSE S

SSW SW WSW W

WNW NW NNW TOTALI 1.0 2.2 0

0 0

0 0

0 0

0 1

0 0

2 1

0 0

0 4

2.2 4.5 5

1 1

1 1

0 1

1 2

1 2

2 0

0 1

2 21 4.5 6.7 1

5 0

0 2

1 2

2 2

2 3

4 0

0 0

2 26 6.7 8.9 2

6 3

1 0

1 2

5 6

4 2

1 0

0 0

1 34 8.9 11.2 0

1 2

1 0

0 0

4 2

1 1

1 0

0 2

4 19 11.2 13.4 0

0 0

0 0

0 0

2 1

1 1

0 0

0 3

5 13 13.4 17.9 0

0 0

0 0

0 0

0 0

0 0

0 0

0 2

1 3

17.9 22.4 0

0 0

0 0

0 0

0 0

0 0

0 0

2 1

0 3

22.4 29.1 0

0 0

0 0

0 0

0 0

0 0

0 0

0 0

0 0

29.1 40.3 0

0 0

0 0

0 0

0 0

0 0

0 0

0 0

0 0

40.3 90.0 0

0 0

0 0

0 0

0 0

0 0

0 0

0 0

0 0

TOTALS 8

13 6

3 3

2 5

14 14 9

9 10 1

2 9

15 123 Stability Class:

All Wind Speed Min Max N

NNE NE ENE E

ESE SE SSE'.

S SSW SW WSW W

WNW NW NNW TOTAL 1.0 2.2 4

2 4

4 4

5 3

2 7

5 5

3 2

4 1

3 58 2.2 4.5 18 11 8

13 13 12 21 15 21 11 15 16 15 10 14 15 228 4.5 6.7 14 13 2

14 15 14 18 19 13 24 17 19 11 8

14 13 228 6.7 8.9 12 14 8

10 3

10 19 30 35 13 17 21 17 17 15 14 255 8.9 11.2 11 16 11 6

3 9

10 14 38 17 10 16 16 17 17 21 232 11.2 13.4 6

3 3

2 0

10 9

9 26 18 17 13 13 20 13 12 174 13.4 17.9 11 3

0 1

1 3

5 9

46 47 25 16 25 49 30 12 283 17.9 22.4 0

0 0

0 0

0 0

1 18 35 24 12 14 78 23 6

211 22.4 29.1 0

0 0

0 0

0 0

0 4

16 28 17 12 53 13 0

143 29.1 40.3 0

0 0

0 0

0 0

0 0

0 2

1 1

6 0

0 10 40.3 90.0 0

0 0

0 0

0 0

0 0

0 0

0 0

0 0

0 0

TOTALS 76 62 36 50 39 63 85 99 208 186 160 134 126 262 140 96 1822 Periods of Calm while in Stability Class:

A B

C D

E F

G Total 0

0 3

7 3

7 3

23 Columbia Generating Station 29 2011 Radioactive Effluent Report Columbia Generating Station 29 2011 Radioactive Effluent Report

Table 5-5 3rd Quarter Average, 33 Ft AGL Hours at each wind speed and direction during time perod Elevation:

33 Start Date:

7/1/2011 Total number of Periods: 2208 Period: 3rd Quarter Stop Date:

10/1/2011 Periods of No Data Recovery:

75 System Percent Data Recovery: 96.6%

Stability Class:

A Wind Speed Min Max N

NNE NE ENE E

ESE SE SSE S

SSW SW WSW W

WNW NW NNW TOTAL 1.0 2.2 0

0 0

0 0

0 0

0 0

0 0

0 0

0 0

0 0

2.2 4.5 0

0 0

0 0

0 0

0 0

0 0

0 0

0 0

1 1

4.5 6.7 3

0 0

0 0

0 0

0 1

0 0

1 0

0 1

2 8

6.7 8.9 1

1 0

0 0

0 0

1 0

0 0

0 0

0 0

1 4

8.9 11.2 2

0 0

0 0

0 0

1 3

1 0

0 0

0 0

0 7

11.2 13.4 0

0 0

0 0

0 0

1 5

1 0

0 0

0 0

0 7

13.4 17.9 0

0 0

0 0

0 0

2 7

1 1

0 0

0 0

0 11 17.9 22.4 0

0 0

0 0

0

,0 0

0 0

0 0

0 1

1 0

2 22.4 29.1 0

0 0

0 0

0 0

0 0

0 0

0 1

1 0

0 2

29.1 40.3 0

0 0

0 0

0 0

0 0

0 0

0 0

0 0

0 0

40.3 90.0 0

0 0

0 0

0 0

0 0

0 0

0 0

0 0

0 0

TOTALS 6

1 0

0 0

0 0

5 16 3

1 1

1 2

2 4

42 Stability Class:

B Wind Speed Min Max N

NNE NE ENE E

ESE SE SSE S

SSW SW WSW W

WNW NW NNW TOTAL 1.0 2.2 0

0 0

0 0

0 0

0 0

0 0

0 0

1 0

0 1

2.2 4.5 2

1 1

0 0

1 0

0 0

0 0

0 0

0 2

5 12 4.5 6.7 8

5 0

0 0

0 0

4 1

1 2

0 0

1 0

8 30 6.7 8.9 3

1 1

1 0

3 1

11 3

0 1

0 0

1 0

3 29 8.9 11.2 1

1 0

1 0

1 0

13 9

3 0

1 0

0 0

0 30 11.2 13.4 1

1 0

0 0

0 0

5 5

2 0

0 0

0 0

0 14 13.4 17.9 0

0 0

0 0

0 0

1 5

1 1

0 0

0 2

0 10 17.9 22.4 0

0 0

0.0 0

0 0

0 0

0 0

0 0

0 0

0 22.4 29.1 0

0 0

0 0

0 0

0 0

0 0

0 0

1 0

0 1

29.1 40.3 0

0 0

0 0

0 0

0 0

0 0

0 0

0 0

0 0

40.3 90.0 0

0 0

0 0

0 0

0 0

0 0

0 0

0 0

0 0

TOTALS 15 9

2 2

0 5

1 34 23 7

4 1

0 4

4 16 127 Stability Class:

C Wind Speed Min Max N

NNE NE ENE E

ESE SE SSE S

SSW SW WSW W

WNW NW NNW TOTAL 1.0 2.2 5

5 1

6 3

1 1

0 1

0 2

1 1

1 0

7 35 2.2 4.5 7

7 7

16 11 12 8

7 5

5 0

1 0

2 7

5 100 4.5 6.7 5

5 7

5 3

9 7

19 9

3 2

5 2

0 3

2 86 6.7 8.9 1

8 0

2 5

1 3

24 10 3

2 2

1 3

4 3

72 8.9 11.2 1

1 1

1 0

0 1

7 10 2

0 0

1 0

2 0

27 11.2 13.4 0

0 0

0 0

0 0

2 5

2 0

2 1

2 1

2 17 13.4 17.9 0

0 0

0 0

0 0

1 6

1 0

0 2

1 3

0 14 17.9 22.4 0

0 0

0 0

0 0

0 1,

0 0

0 0

1 1

0 3

22.4 29.1 0

0 0

0 0

0 0

0 0

0 0

1 0

1 0

0 2

29.1 40.3 0

0 0

0 0

0 0

0 0

0 0

0 0

0 0

0 0

40.3 90.0 0

0 0

0 0

0 0

0 0

0 0

0 0

0 0

0 0

TOTALS 19 26 16 30 22 23 20 60 47 16 6

12 8

11 21 19 356 Stability Class:

D Wind Speed Min Max N

NNE NE ENE E

ESE SE SSE S

SSW SW WSW W

WNW NW NNW TOTAL 1.0 2.2 3

1 12 15 18 9

4 3

1 2

2 3

0 3

2 1

79 2.2 4.5 2

6 15 19 30 13 25 11 6

3 1

2 3

2 2

1 141 4.5 6.7 2

2 5

11 16 11 11 13 8

4 3

0 7

3 3

2 101 6.7 8.9 1

4 4

5 4

11 10 11 4

2 1

3 5

1 0

2 68 8.9 11.2 0

0 1

0 0

1 5

7 9

3 4

0 3

5 3

0 41 11.2 13.4 0

0 0

0 0

0 1

1 7

4 1

2 5

5 3

0 29 13.4 17.9 0

0 0

0 0

0 0

2 3

4 2

2 3

18 8

0 42 17.9 22.4 0

0 0

0 0

0 0

0 0

1 1

4 0

4 6

0 16 22.4 29.1 0

0 0

0 0

0 0

0 0

0 0

1 0

1 0

0 2

29.1 40.3 0

0 0

0 0

0 0

0 0

0 0

0 0

0 0

0 0

40.3 90.0 0

0 0

0 0

0 0

0 0

0 0

0 0

0 0

0 0

TOTALS 8

13 37 50 68 45 56 48 38 23 15 17 26 42 27 6

519 Columbia Generating Station 30 2011 Radioactive Effluent Report

Table 5-5 3rd Quarter Average, 33 Ft AGL (Continued)

Stabilitv Class:

E Stability Cl.......

Wind Speed Min Max N

NNE NE ENE E

ESE SE SSE S

SSW SW WSW W

WNW NW NNW TOTAL 1.0 2.2 5

2 3

3 5

0 4

6 3

3 1

0 0

2 2

3 42 2.2 4.5 1

1 2

3 4

7 10 8

3 3

4 3

8 4

2 7

70 4.5 6.7 0

2 4

0 0

7 11 12 1

6 2

3 8

9 9

4 78 6.7 8.9 1

0 1

0 0

5 9

11 3

0 4

4 6

8 11 1

64 8.9 11.2 0

0 0

0 0

0 5

10 2

1 0

1 4

10 9

0 42 11.2 13.4 0

0 0

0 0

0 1

7 0

2 0

0 1

11 4

0 26 13.4 17.9 0

0 0

0 0

0 0

1 1

1 2

0 0

10 3

0 18 17.9 22.4 0

0 0

0 0

0 0

0 0

0 0

0 0

1 0

0 1

22.4 29.1 0

0 0

0 0

0 0

0 0

0 0

0 0

0 0

0 0

29.1 40.3 0

0 0

0 0

0 0

0 0

0 0

0 0

0 0

0 0

40.3 90.0 0

0 0

0 0

0 0

0 0

0 0

0 0

0 0

0 0

TOTALS 7

5 10 6

9 19 40 55 13 16 13 11 27 55 40 15 341 Stability Class:

F Wind Speed Min Max N

NNE NE ENE E

ESE SE SSE S

SSW SW WSW W

WNW NW NNW TOTAL 1.0 2.2 4

4 4

3 3

4 6

9 5

4 3

1 3

3 3

1 60 2.2 4.5 2

9 6

1 1

7 21 11 13 5

3 3

4 2

9 5

102 4.5 6.7 2

1 3

1 0

2 15 19 4

3 1

3 2

5 9

4 74 6.7 8.9 0

0 0

0 0

1 8

9 6

1 1

1 0

3 2

0 32 8.9 11.2 0

0 0

0 0

0 3

3 4

0 0

1 0

0 1

0 12 11.2 13.4 0

0 0

0 0

0 0

0 0

0 0

0 0

0 0

0 0

13.4 17.9 0

0 0

0 0

0 0

0 0

0 0

0 0

0 0

0 0

17.9 22.4 0

0 0

0 0

0 0

0 0

0 0

0 0

0 0

0 0

22.4 29.1 0

0 0

0 0

0 0

0 0

0 0

0 0

0 0

0 0

29.1 40.3 0

0 0

0 0

0 0

0 0

0 0

0 0

0 0

0 0

40.3 90.0 0

0 0

0 0

0 0

0 0

0 0

0 0

0 0

0 0

TOTALS 8

14 13 5

4 14 53 51 32 13 8

9 9

13 24 10 280 Stability Class:

G Wind Speed Min Max N

NNE NE ENE E

ESE SE SSE S

SSW SW WSW W

WNW NW NNW TOTAL 1.0 2.2 9

16 17 6

4 9

13 3

2 1

1 1

2 1

6 7

98 2.2 4.5 11 17 28 1

0 1

12 13 7

0 0

0 1

0 4

8 103 4.5 6.7 3

0 11 1

0 0

12 11 1

2 0

0 0

0 3

3 47 6.7 8.9 0

0 1

0 0

0 2

5 0

1 1

0 0

0 0

1 11 8.9 11.2 0

0 0

0 0

0 0

2 0

1 0

0 0

0 0

0 3

11.2 13.4 0

0 0

0 0

0 0

0 0

1 0

0 0

0 0

0 1

13.4 17.9 0

0 0

0 0

0 0

0 0

0 0

0 0

0 0

0 0

17.9 22.4 0

0 0

0 0

0 0

0 0

0 0

0 0

0 0

0 0

22.4 29.1 0

0 0

0 0

0 0

0 0

0 0

0 0

0 0

0 0

29.1 40.3 0

0 0

0 0

0 0

0 0

0 0

0 0

0 0

0 0

40.3 90.0 0

0 0

0 0

0 0

0 0

0 0

0 0

0 0

0 0

rTOTALS 23 33 57 8

4 10 39 34 10 6

2 1

3 1

13 19 263 Stability Class:

All Wind Speed Min Max N

NNE NE ENE E

ESE SE SSE S

SSW SW WSW W

WNW NW NNW TOTAL 1.0 22 26 28 37 33 2.2 4.5 25 41 59 40 4.5 6.7 23 15 30 18 6.7 8.9 7

14 7

8 8.9 11.2 4

2 2

2 11.2 13.4 1

1

0.

0 13.4 17.9 0

0 0

0 17.9 22.4 0

0 0

0 22.4 29.1 0

0 0

0 29.1 40.3 0

0 0

0 40.3 90.0 0

0 0

0 33 46 19 9

0 0

0 0

0 0

0 23 28 21 12 10 9

6 6

11 13 19 41 76 50 34 16 8

9 16 10 26 32 29 56 78 25 19 10 12 19 18 28 25 21 33 72 26 7

10 10 12 16 17 11 2

14 43 37 11 4

3 8

15 15 0

0 2

16 22 12 1

4 7

18 8

2 0

0 7

22 8

6 2

5 29 16 0

0 0

0 1

1 1

4 0

7 8

0 0

0 0

0 0

0 2

1 4

0 0

0 0

0 0

0 0

0 0

0 0

0 0

0 0

0 0

0 0

0 0

0 0

315 529 424 280 162 94 95 22 7

0 0

jTOTALS 86 101 135 101 107 116 209 287 179 84 49 52 74 128 131 89 1928 4A B

C D

E F

G Totall Columbia3 Geeatn Staio 31 201Rdiatv0EfuntRpr Columbia Generating Station 31 2011 Radioactive Effluent Report

Table 5-6 3rd Quarter Average, 245 Ft AGL Hours at each wind speed and direction during time period Elevation:

245 Start Date:

7/1/2011 Total number of Periods: 2208 Period: 3rd Quarter Stop Date:

10/1/2011 Periods of No Data Recovery:

75 System Percent Data Recovery: 96.6%

Stability Class:

A Wind Speed Min Max N

NNE NE ENE E

ESE SE SSE S

SSW SW WSW W

WNW NW NNW TOTAL 1.0 2.2 0

0 0

0 0

0 0

0 0

0 0

0 0

0 0

0 0

2.2 4.5 0

0 0

0 0

0 0

0 0

0 0

0 0

0 0

0 0

4.5 6.7 2

0 0

0 0

0 0

0 0

0 0

0 0

0 1

1 4

6.7 8.9 2

1 0

0 0

0 0

0 1

0 0

0 1

0 0

1 6

8.9 11.2 4

0 0

0 0

0 0

0 1

1 0

0 0

0 0

0 6

11.2 13.4 0

0 0

0 0

0 0

0 4

0 0

0 0

0 0

0 4

13.4 17.9 0

0 0

0 0

0 0

0 11 5

0 0

0 0

0 0

16 17.9 22.4 0

0 0

0 0

0 0

0 0

1 1

0 0

0 0

0 2

22.4 29.1 0

0 0

0 0

0 0

0 0

0 0

0 1

1 1

0 3

29.1 40.3 0

0 0

0 0

0 0

0 0

0 0

0 0

1 0

0 1

40.3 90.0 0

0 0

0 0

0 0

0 0

0 0

0 0

0 0

0 0

'TOTALS 8

1 0

0 0

0 0

0 17 7

1 0

2 2

2 2

42 Stability Class:

B Wind Speed Min Max N

NNE NE ENE E

ESE SE SSE S

SSW SW WSW W

WNW NW NNW TOTAL 1.0 2.2 0

0 0

0 0

0 0

0 0

0 0

0 0

0 0

0 0

2.2 4.5 4

0 1

0 0

1 0

0 0

0 0

0 0

0 1

2 9

4.5 6.7 8

3 0

0 0

0 0

2 0

1 0

1 0

0 0

8 23 6.7 8.9 6

4 1

1 0

0 0

2 2

1 0

1 1

0 0

1 20 8.9 11.2 0

1 1

1 0

2 1

8 9

2 1

0 0

1 0

1 28 11.2 13.4 2

0 1

0 0

1 1

2 14 3

2 1

0 0

0 0

27 13.4 17.9 0

0 0

0 0

0 0

1 9

5 0

0 0

0 0

0 15 17.9 22.4 0

0 0

0 0

0 0

0 1

0 1

0 0

0 2

0 4

22.4 29.1 0

0 0

0 0

0 0

0 0

0 0

0 0

0 0

0 0

29.1 40.3 0

0 0

0 0

0 0

0 0

0 0

0 0

1 0

0 1

40.3 90.0 0

0 0

0 0

0 0

0 0

0 0

0 0

0 0

0 0

TOTALS 20 8

4 2

0 4

2 15 35 12 4

3 1

2 3

12 127 Stability Class:

C Wind Speed Min Max N

NNE NE ENE E

ESE SE SSE S

SSW SW WSW W

WNW NW NNW TOTAL 1.0 2.2 3

2 0

1 6

1 0

1 0

0 1

0 1

0 2

3 21 2.2 4.5 9

5 5

15 8

7 3

5 5

1 2

0 1

3 4

5 78 4.5 6.7 3

6 3

7 4

10 7

13 11 4

1 5

0 0

3 4

81 6.7 8.9 2

6 4

3 2

5 1

21 10 5

1 3

1 0

6 2

72 8.9 11.2 1

3 1

0 2

3 0

8 19 2

2 1

2 3

1 0

48 11.2 13.4 1

0 0

1 3

1 0

2 6

4 1

0 0

1 1

1 22 13.4 17.9 0

0 0

0 0

0 0

0 10 5

0 2

1 3

1 0

22 17.9 22.4 0

0 0

0 0

0 0

0 0

1 1

0 1

1 3

0 7

22.4 29.1 0

0 0

0 0

0 0

0 0

1 0

0 0

1 1

0 3

29.1 40.3 0

0 0

0 0

0 0

0 0

0 0

1 0

0 1

0 2

40.3 90.0 0

0 0

0 0

0 0

0 0

0 0

0 0

0 0

0 0

TOTALS 19 22 13 27 25 27 11 50 61 23 9

12 7

12 23 15 356 Stability Class:

D Wind Speed Min Max N

NNE NE ENE E

ESE SE SSE S

SSW SW WSW W

WNW NW NNW TOTAL 1.0 2,2 1

2 5

10 9

4 6

3 2

1 2

3 2

2 0

0 52 2.2 4,5 4

5 8

17 27 12 10 12 7

3 3

2 1

4 3

0 118 4.5 6,7 1

2 4

9 7

16 6

11 7

5 1

2 2

1 2

0 76 6.7 8,9 2

3 4

8 9

9 4

8 12 4

1 3

6 2

3 2

80 8.9 11.2 0

1 2

3 5

14 3

9 9

4 1

3 3

3 0

1 61 11.2 13.4 0

0 1

0 0

5 2

3 3

6 1

1 3

0 3

0 28 13.4 17.9 0

0 0

0 0

0 2

3 9

7 3

2 6

5 8

0 45 17.9 22.4 0

0 0

0 0

0 0

1 1

3 4

3 3

5 9

0 29 22.4 29.1 0

0 0

0 0

0 0

0 0

0 2

3 1

11 11 0

28 29.1 40.3 0

0 0

0 0

0 0

0 0

0 0

0 1

0 2

0 3

40.3 90.0 0

0 0

0 0

0 0

0 0

0 0

0 0

0 0

0 0

TOTALS 8

13 24 47 57 60 33 50 50 33 18 22 28 33 41 3

520 Columbia Generating Station 32 2011 Radioactive Effluent Report

Table 5-6 3rd Quarter Average, 245 Ft AGL (Continued)

Stability Class:

E Wind Speed Min.

Max N

NNE NE ENE E

ESE SE SSE S

SSW SW WSW W

WNW NW NNW TOTAL 1.0 2.2 1

0 2

1 2

0 1

1 0

2 0

0 1

0 0

0 11 2.2 4.5 1

0 0

3 1

2 4

4 2

4 3

4 0

3 1

0 32 4.5 6.7 0

2 0

2 3

2 4

8 1

2 1

1 1

6 8

2 43

.6.7 8.9 0

1 2

1 1

3 2

6 7

1 2

2 5

5 1

2 41 8.9 11.2 0

0 1

0 1

2 1

9 8

5 1

3 2

10 8

2 53 11.2 13.4 2

0 0

0 0

2 4

5 8

0 1

2 5

12 10 0

51 13.4 17.9 0

0 0

0 0

1 1

5 9

5 0

1 3

16 22 0

63 17.9 22.4 0

0 0

0 0

0 0

1 6

2 0

0 1

17 12 0

39 22.4 29.1 0

0 0

0 0

0 0

0 1

2 2

0 0

10 2

0 17 29.1 40.3 0

0 0

0 0

0 0

0 0

0 0

0 0

0 0

0 0

40.3 90.0 0

0 0

0 0

0 0

0 0

0 0

0 0

0 0.0 0

TOTALS 4

3 5

7 8

12 17 39 42 23 10 13 18 79 64 6

350 Stability Class:

F Wind Speed Min Max N

NNE NE ENE E

ESE SE SSE S

SSW SW WSW W

WNW NW NNW TOTAL 1.0 2.2 0

0 3

1 0

2 0

2 2

3 0

2 1

1 2

0 19 2.2 4.5 7

5 2

1 2

0 4

4 5

0 2

3 3

5 6

5 54 4.5 6.7 5

3 4

1 2

3 6

8 7

3 3

5 8

3 3

2 66 6.7 8.9 0

0 1

2 1

2 3

12 10 4

2 2

2 2

8 3

54 8.9 11.2 1

0 0

0 0

0 1

8 7

3 2

0 2

5 9

1 39 11.2 13.4 1

0 0

0 0

0 4

9 3

3 0

1 3

5 4

0 33 13.4 17.9 0

0 0

0 0

0 4

6 4

3 0

0 5

10 4

1 37 17.9 22.4 0

0 0

0 0

0 0

0 0

0 0

0 0

2 1

0 3

22.4 29.1 0

0 0

0 0

0 0

0 0

0 0

0 0

0 0

0 0

29.1 40.3 0

0 0

0 0

0 0

0 0

0 0

0 0

0 0

0 0

40.3 90.0 0

0 0

0 0

0 0

0 0

0 0

0 0

0 0

0 0

TOTALS 14 8

10 5

5 7

22 49 38 19 9

13 24 33 37 12 305 Stability Class:

G Wind Speed Min Max N

NNE NE ENE E

ESE SE SSE S

SSW SW WSW W

WNW NW NNW TOTAL 1.0 2.2 6

3 1

2 2

4 5

7 2

4 3

1 1

0 3

2 46 2.2 4.5 5

8 5

2 2

7 10 9

7 5

3 0

0 2

5 3

73 4.5 6.7 9

7 3

0 3

4 11 10 9

6 2

0 1

0 3

10 78 6.7 8.9 5

5 2

1 1

2 5

11 6

7 1

0 1

2 2

10 61 8.9 11.2 1

1 2

4 0

0 0

7 4

3 0

1 0

0 4

6 33

'11.2 13.4 0

0 0

2 0

0 1

7 1

3 1

0 0

1 5

4 25 13.4 17.9 0

0 0

0 0

0 0

1 3

1 2

0 1

2 1

0 11 17.9 22.4 0

0 0"

0 0

0 0

0 1

0 0

0 1

0 0

0 2

22.4 29.1 0

0 0

0 0

0 0

0 0

0 0

0 0

0 0

0 0

29.1 40.3 0

0 0

0 0

0 0

0 0

0 0

0 0

0 0

0 0

40.3 90.0 0

0 0

0 0

0 0

0 0

0 0

0 0

0 0

0 0

TOTALS 26 24 13 11 8

17 32 52 33 29 12 2

5 7

23 35 329 Stability Class:

All Wind Speed Min Max N

NNE NE ENE E

ESE SE SSE S

SSW SW WSW W

WNW NW NNW TOTALI 1.0 2.2 11 7

11 15 19 11 12 14 6

10 6

2.2 4.5 30 23 21 38 40 29 31 34 26 13 13 4.5 6.7 28 23 14 19 19 35 34 52 35 21 8

6.7 8.9 17 20 14 16 14 21 15 60 48 22 7

8.9 11.2 7

6 7

8 8

21 6

49 57 20 7

11.2 13.4 6

0 2

3 3

9 12 28 39 19 6

13.4 17.9 0

0 0

0 0

1 7

16 55 31 5

17.9 22.4 0

0 0

0 0

0 0

2 9

7 7

22.4 29.1 0

0 0

0 0

0 01 0

1 3

4 29.1 40.3 0

0 0

0 0

0 0

0 0

0 0

40.3 90.0 0

0 0

0 0

0 0

0 0

0 0

6 6

3 7

5 149 9

5 17 20 15 364 14 12 10 20 27 371 11 17 11 20 21 334 8

9 22 22 11 268 5

11 19 23 5

190 5

16 36 36 1

209 3

6 25 27 0

86 3

2 23 15 0

51 1

1 2

3 0

7 0

0 0

0 0

0

[TOTALS 99 79 69 99 103 127 117 255 276 146 63 65 85 168 193 85 2029 Perods of Calm while in Stability Class:

A B

C D

E F

G Total 0

1 4

33 14 21 31 1041 Columbia Generating Station 33 2011 Radioactive Effluent Report

Table 5-7 4th Quarter Average, 33 Ft AGL Hours at each wind speed and direction during time period Elevation:

33 Start Date:

10/1/2011 Total number of Periods: 2208 Period: 4th Quarter Stop Date:

1/1/2012 Periods of No Data Recovery: 342 System Percent Data Recovery: 84.5%

Stability Class:

A Wind Speed Min Max N

NNE NE ENE E

ESE SE SSE S

SSW SW WSW W

WNW NW NNW TOTAL 1.0 2.2 0

0 0

0 0

0 0

0 0

0 0

0 0

0 0

0 0

2.2 4.5 0

0 0

0 0

0 0

0 0

0 0

0 0

0 0

1 1

4.5 6.7 0

0 0

0 0

0 0

0 0

0 0

0 0

0 0

0 0

6.7 8.9 0

0 C

0 0

0 0

0 0

0 0

0 0

0 0

0 0

8.9 11.2 0

0 0

0 0

0 0

0 0

0 0

0 0

0 0

0 0

11.2 13.4 0

0 0

0 0

0 0

0 0

0 0

0 0

0 0

0 0

13.4 17.9 0

0 0

0 0

0 0

0 0

0 0

0 0

0 0

0 0

17.9 22.4 0

0 0

0 0

0 0

0 0

0 0

0 0

0 0

0 0

22.4 29.1 0

0 0

0 0

0 0

0 0

0 0

0 0

0 0

0 0

29.1 40.3 0

0 0

0 0

0 0

0 0

0 0

0 0

0 0

0.

0 40.3 90.0 0

0 0

0 0

0 0

0 0

0 0

0 0

0 0

0 0

TOTALS 0

0 0

0 0

0 0

0 0

0 0

0 0

0 0

1 1

Stability Class:

B Wind Speed Min Max N

NNE NE ENE E

ESE SE SSE S

SSW. SW WSW W

WNW NW NNW TOTAL 1.0 2.2 0

0 0

0 0

0 0

0 0

0 0

0 0

0 0

0 0

2.2 4.5 0

0 0

0 0

1 0

0 0

0 0

0 0

0 0

1 2

4.5 6.7 0

0 0

0 0

0 0

1 0

0 0

0 0

0 0

0 1

6.7 8.9 0

0 0

0 0

0 1

0 0

0 0

0 0

0 0

0 1

8.9 11.2 1

0 0

0 0

0 0

1 0

0 0

0 0

0 0

1 3

11.2 13.4 0

0 0

0 0

0 0

1 0

0 0

0 0

0 0

0 1

13.4 17.9 0

0 0

0 0

0 0

0 0

0 0

0 0

0 0

0 0

17.9 22.4 0

0 0

0 0

0 0

0 0

1 0

0 0

0 0

0 1

22.4 29.1 0

0 0

0 0

0 0

0

'0 1

2 0

0 0

0 0

3 29.1 40.3 0

0 0

0 0

0 0

0 0

0 0

0 0

0 0

0 0

40.3 90.0 0

0 0

0 0

0 0

0 0

0 0

0 0

0 0

0 0

TOTALS 1

0 0

0 0

1 1

3 0

2 2

0 0

0 0

2 12 Stability Class:

C Wind Speed Min Max N

NNE NE ENE E

ESE SE SSE S

SSW SW WSW W

WNW NW NNW TOTAL 1.0 2.2 2

0 0

0 0

1 0

0 0

0 0

0 0

0 0

2 5

2.2 4.5 3

0 0

0 0

0 0

0 0

0 0

01 0

0 4

5 12 4.5 6.7 1

0 0

0 0

0 0

0 0

0 0

0 0

1 0

7 9

6.7 8.9 0

0 0

0 0

0 0

3 0

0 1

0 0

2 0

1 7

8.9 11.2 0

0 0

0 0

0 0

3 0

0 0

0 1

0 0

2 6

11.2 13.4

0.

0 0

0 0

0 0

0 0

0 1

0 0

0 1

0 2

13.4 17.9 0

0 0

0 0

0 0

1 3

0 1

0 1

0 1

0 7

17.9 22.4 0

0 0

0 0

0 0

0 0

1 3

0 0

1 0

0 5

22.4 29.1 0

0 0

0 0

0 0

0 0

0 0

0 0

0 0

0 0

29.1 40.3 0

0 0

0 0

0 0

0 0

0 0

0 0

0 0

0 0

40.3 90.0 0

0 0

0 0

0 0

0 0

0 0

0 0

0 0

0 0

TOTALS 6

0 0

0 0

1 0

7 3

1 6

0 2

4 6

17 53 Stability Class:

D Wind Speed Min Max N

NNE NE ENE E

ESE SE SSE S

SSW SW WSW W

WNW NW NNW TOTAL 1.0 2.2 8

10 7

4 5

4 5

5 6

4 6

0 13 7

12 20 116 2.2 4.5 7

13 5

2 3

2 5

12 8

4 8

7 12 17 21 16 142 4.5 6.7 0

4 2

1 1

3 15 9

6 6

5 0

4 13 9

11 89 6.7 8.9 0

0 0

0 0

3 13 22 15 2

1 2

5 3

10 4

80 8.9 11.2 0

0 0

0 0

0 4

8 6

2 1

2 2

2 1

1 29 11.2 13.4 0

0 0

0 0

0

.0 7

8 4

0 2

2 5

1 0

29 13.4 17.9 0

0 0

0 0

0 0

1 5

8 2

3 2

3 3

0 27 17.9 22.4 0

0 0

0 0

0 0

0 3

4 1

1 1

1 1

0 12 22.4 29.1 0

0 0

0 0

0 0

0 0

1 0

0 0

0 0

0 1

29.1 40.3 0

0 0

0 0

0 0

0 0

0 0

0 0

0 0

0 0

40.3 90.0 0

0 0

0 0

0 0

0 0

0.

0

0.

0 0

0 0

0 TOTALS 15 27 14 7

9 12 42 64 57 35 24 17 41 51 58 52 525 Columbia Generating Station 34 2011 Radioactive Effluent Report

Table 5-7 4th Quarter Average, 33 Ft AGL (Continued)

Stability Class:

E Wind Speed Min Max N

NNE NE ENE E

ESE SE SSE S

SSW SW WSW W

WNW NW NNW TOTAL 1.0 2.2 4

4 6

0 1

1 2

6 3

5 3

3 0

6 2

4 50 2.2 4.5 2

3 2

0 3

1 7

9 5

12 8

10 7

9 10 12 100 4.5 6.7 1

0 1

0 0

0 6

15 13 6

6 6

7 11 3

4 79 6.7 8.9 0

0 0

0 0

1 12 15 8

3 0

0 4

6 2

0 51 8.9 11.2 0

0 0

0 0

2 8

7 6

4 1

2 3

6 0

1 40 11.2 13.4 0

0 0

0 0

1 1

13 7

4 3

2 5

6 2

0 44 13.4 17.9 0

0 0

0 0

0 3

10 20 8

2 0

2 10 1

0 56 17.9 22.4 0

0 0

0 0

0 0

1 6

6 4

1 2

0 0

0 20 22.4 29.1 0

0 0

0 0

0 0

0 2

7 2

2 1

0 0

0 14 29.1 40.3 0

0 0

0 0

0 0

0 0

0 0

0 0

0 0

0 0

40.3 90.0 0

0 0

0 0

0 0

0 0

0 0

0 0

0 0

0 0

TOTALS 7

7 9

0 4

6 39 76 70 55 29 26 31 54 20 21 454 Stability Class:

F Wind Speed Min Max N

NNE NE ENE E

ESE SE SSE S

SSW SW WSW W

WNW NW NNW TOTAL 1.0 2.2 6

6 6

0 2

3 3

6 1

3 3

1 2

5 7

6 60 2.2 4.5 4

3 3

0 0

2 1

11 7

6 4

5 3

11 20 9

89 4.5 6.7 4

1 4

0 0

0 7

16 11 3

6 1

2 4

14 6

79 6.7 8.9 0

0 0

0 0

0 4

14 7

3 1

1 2

1 3

0 36 8.9 11.2 0

0 0

0 0

0 2

3 1

3 0

2 1

4 2

0 18 11.2 13.4 0

0 0

0 0

0 0

1 0

3 0

0 0

1 0

0 5

13.4 17.9 0

0 0

0 0

0 2

1 1

4 0

0 0

0 0

0 8

17.9 22.4 0

0 0

0 0

0 0

0 0

1 0

0 0

0 0

0 1

22.4 29.1 0

0 0

0 0

0 0

0 0

0 0

0 0

0 0

0 0

29.1 40.3 0

0 0

0 0

0 0

0 0

0 0

0 0

0 0

0 0

40.3 90.0 0

0 0

0 0

0 0

0 0

0 0

0 0

0 0

0 0

TOTALS 14 10 13 0

2 5

19 52 28 26 14 10 10 26 46 21 296 Stability Class:

G Wind Speed Min Max N

NNE NE ENE E

ESE SE SSE S

SSW SW WSW W

WNW NW NNW TOTAL 1.0 2.2 4

8 7

0 0

1 1

3 4

.3 2

6 7

14 13 15 88 2.2 4.5 6

4 2

0 0

0 4

10 7

3 3

8 5

6 19 12 89 4.5 6.7 0

0 1

0 0

0 1

8 3

5 1

0 1

3 7

5 35 6.7 8.9 0

0 0

0 0

0 0

11 2

1 8

0 0

1 5

2 30 8.9 11.2 0

0 0,

0 0

0 0

1 0

2 1

1 0

0 0

0 5

11.2 13.4 0

0 0

0 0

0 0

0 0

1 0

0 0

0 0

0 1

13.4 17.9 0

0 0

0 0

0 0

0 0

0 0

0 0

0 0

0 0

17.9 22.4 0

0 0

0 0

0 0

0 0

0 0

0 0

0 0

0 0

22.4 29.1 0

0 0

0 0

0 0

0 0

0 0

0 0

0 0

0 0

29.1 40.3 0

0 0

0 0

0 0

0 0

0 0

0 0

0 0

0 0

40.3 90.0 0

0 0

0 0

0 0

0 0

0 0

0 0

0 0

0 0

TOTALS 10 12 10 0

0 1

6 33 16 15 15 15 13 24 44 34 248 Stability Class:

All Wind Speed Min Max N

NNE NE ENE E

ESE SE SSE S

SSW SW WSW W

WNW NW NNW TOTAL 1.0 2.2 24 28 26 4

8 10 11 20 14 15 14 10 22 32 34 47 319 2.2 4.5 22 23 12 2

6 6

17 42 27 25 23 30 27 43 74 56 435 4.5 6.7 6

5 8

1 1

3 29 49 33 20 18 7

14 32 33 33 292 6.7 8.9 0

0 0

0 0

4 30 65 32 9

11 3

11 13 20 7

205 8.9 11.2 1

0 0

0 0

2 14 23 13 11 3

7 7

12 3

5 101 11.2 13.4 0

0 0

0 0

1 1

22 15 12 4

4 7

12 4

0 82 13.4 17.9 0

0 0

0 0

0 5

13 29 20 5

3 5

13 5

0 98 17.9 22.4 0

0 0

0 0

0 0

1 9

13 8

2 3

2 1

0 39 22.4 29.1 0

0 0

0 0

0 0

0 2

9 4

2 1

0 0

0 18 29.1 40.3 0

0 0

0 0

0 0

0 0

0 0

0 0

0 0

0 0

40.3 90.0 0

0 0

0 0

0 0

0 0

0 0

0 0

0 0

0 0

TOTALS 53 56 46 7

15 26 107 235 174 134 90 68 97 159 174 148 1589 Periods of Calm while in Stability Class:

I A

B C

D E

IF G

Total 0

0 2

93 50 57 75 277 Columbia Generating Station 35 2011 Radioactive Effluent Report

Table 5-8 4th Quarter Average, 245 Ft AGL Hours at each wind speed and direction during time period

[Elevation:

245 Start Date:

10/1/2011 Total number of Periods: 2208 Period: 4th Quarter Stop Date:

1/1/2012 Periods of No Data Recovery:

342 System Percent Data Recovery: 84.5%

Stability Class:

A Wind Speed Min Max N

NNE NE ENE E

ESE SE SSE S

SSW SW WSW W

WNW NW NNW TOTAL 1.0 2.2 0

0 0

0 0

0 0

0 0

0 0

0 0

0 0

0 0

2.2 4.5 0

0 0

0 0

0 0

0 0

0 0

0 0

0 0

1 1

4.5 6.7 0

0 0

0 0

0 0

0 0

0 0

0 0

0 0

0 0

6.7 8.9 0

0 0

0 0

0 0

0 0

0 0

0 0

0 0

0 0

8.9 11.2 0

0 0

0 0

0 0

0 0

.0 0

0 0

0 0

0 0

11.2 13.4 0

0 0

0 0

0 0

0 0

0 0

0 0

0 0

0 0

13.4 17.9 0

0 0

0 0

0 0

0 0

0 0

0 0

0 0

0 0

17.9 22.4 0

0 0

0 0

0 0

0 0

0 0

0 0

0 0

0 0

22.4 29.1 0

0 0

0 0

0 0

0 0

0 0

0 0

0 0

0 0

29.1 40.3 0

0 0

0 0

0 0

0 0

0 0

0 0

0 0

0 0

40.3 90.0 0

0 0

0 0

0 0

0 0

0 0

0 0

0 0

0 0

TOTALS 0

0 0

0 0

0 0

0 0

0 0

0 0

0 0

1 1

Stability Class:

B Wind Speed Min Max N

NNE NE.

ENE E

ESE SE SSE S

SSW SW WSW W

WNW NW NNW TOTAL 1.0 2.2 0

0 0

0 0

0 0

0 0

0 0

0 0

0 0

0 0

2.2 4.5 1

0 0

0 0

0 1

0 0

0 0

0 0

0 0

0 2

4.5 6.7 0

0 0

0 0

0 1

1 0

0 0

0 0

0 0

0 2

6.7 8.9 0

0 0

0 0

0 0

0 0

0 0

0 0

0 0

0 0

8.9 11.2 1

0 0

0 0

0 0

0 0

0 0

0 0

0 0

0 1

11.2 13.4 0

0 0

0 0

0 0

0 2

0 0

0 0

0 0

1 3

13.4 17.9 0

0 0

0 0

0 0

0 0

0 0

0 0

0 0

0 0

17.9 22.4 0

0 0

0 0

0 0

0 0

0 0

0 0

0 0

0 0

22.4 29.1 0

0 0

0 0

0 0

0 0

0 1

0 0

0 0

0 1

29.1

.40.3 0

0 0

0 0

0 0

0 0

0 3

0 0

0 0

0 3

40.3 90.0 0

0 0

0 0

0 0

0 0

0 0

0 0

0 0

0 0

TO TALS 2

0 0

0 0

0 2

1 2

0 4

0 0

0 0

1 12 Stability Class:

C Wind Speed Min Max N

NNE NE ENE E

ESE SE SSE S

SSW SW WSW W

WNW NW NNW TOTAL 1.0 2.2 2

0 0

1 0

0 0

0 0

0 0

0 0

0 0

0 3

2.2 4.5 3

1 0

0 0

1 0

0 0

0 0

0 0

0 2

5 12 4.5 6.7 0

0 0

0 0

0 0

0 0

0 0

0 0

0 1

7 8

6.7 8.9 0

0 0

0 0

0 0

1 1

0 1

0 0

0 1

2 6

8.9 11.2 2

0 0

0 0

0 0

1 1

0 0

0 0

2 0

1 7

11.2 13.4 0

0 0

0 0

0 0

2 0

0 0

0 1

0 0

1 4

13.4 17.9 0

0 0

0 0

0 0

0 2

0 0

1 0

0 2

0 5

17.9 22.4 0

0 0

0 0

0 0

0 1

1 0

1 1

0 0

0 4

22.4 29.1 0

0 0

0 0

0 0

0 0

1 3

0 0

1 0

0 5

29.1 40.3 0

0 0

0 0

0 0

0 0

0 0

0 0

0 0

0 0

40.3 90.0 0

0 0

0 0

0 0

0 0

0 0

0 0

0 0

0 0

TOTALS 7

1 0

1 0

1 0

4 5

2 4

2 2

3 6

16 54 Stability Class:

D Wind Speed Min Max N

NNE NE ENE E

ESE SE SSE S

SSW SW WSW W

WNW NW NNW TOTAL 1.0 2.2 4

5 4

3 3

1 4

8 7

7 4

5 3

9 9

9 85 2.2 4.5 6

9 8

3 3

4 1

9 7

5 7

3 3

8 11 6

93 4.5 6.7 4

6 2

1 1

1 10 10 6

6 4

7 4

9 10 9

90 6.7 8.9 2

1 2

1 0

1 8

11 8

4 2

5 3

4 10 9

71 8.9 11.2 0

0 0

0 0

1 3

14 14 5

1 0

5 4

11 3

61 11.2 13.4 0

0 0

0 0

0 1

7 4

1 1

1 3

2 6

1 27 13.4 17.9 0

0 0

0 0

0 1

2 10 12 3

3 2

5 1

1 40 17.9 22.4 0

0 0

0 0

0 0

0 3

8 3

2 2

3 4

1 26 22.4 29.1 0

0 0

0 0

0 0

0 0

3 7

2 0

4 1

0 17 29.1 40.3 0

0 0

0 0

0 0

0 0

3 0

0 0

0 0

0 3

40.3 90.0 0

0 0

0 0

0 0

0 0

0 0

0 0

0 0

0 0

TOTALS 16 21 16 8

7 8

28 61 59 54 32 28 25 48 63 39 513 Columbia Generating Station 36 2011 Radioactive Effluent Report

Table 5-8 4th Quarter Average, 245 Ft AGL (Continued)

Stability Class:

E Wind Speed Min Max N

NNE NE ENE E

ESE SE SSE S

SSW SW WSW W

WNW NW NNW TOTAL 1.0 2.2 4

3 0

0 0

1 2

3 2

0 1

0 1

2 1

2 22 2.2 4.5 4

7 1

0 4

3 6

6 8

2 4

6 2

4 0

5 62 4.5 6.7 4

3 2

2 1

1 2

9 5

4 4

6 3

3 8

3 60 6.7 8.9 2

1 1

1 0

0 4

6 6

5 3

5 4

7 9

1 55 8.9 11.2 0

1 1

1 0

0 3

13 7

7 3

1 5

5 6

2 55 11.2 13.4 0

0 0

0 0

0 1

9 7

1 1

0 2

5 2

0 28 13.4 17.9 0

0 0

0 0

2 2

4 14 10 3

0 2

3 4

2 46 17.9 22.4 0

0 0

0 0

0 0

4 14 14 6

0 4

9 0

1 52 22.4 29.1 0

0 0

0 0

0 1

1 8

17 9

2 1

17 1

0 57 29.1 40.3 0

0 0

0 0

0 0

0 4

12 3

4 3

1 0

0 27 40.3 90.0 0

0 0

0 0

0 0

0 0

0 0

1 0

0 0

0 1

ITOTALS 14 15 5

4 5

7 21 55 75 72 37 25 27 56 31 16 465 Stability Class:

F Wind Speed Min Max N

NNE NE ENE E

ESE SE SSE S

SSW SW WSW W

WNW NW NNW TOTAL 1.0 2-2 0

1 3

2 2

2 2

5 2

2 3

3 1

0 2

0 30 2.2 4.5 10 5

3 5

1 1

5 2

10 5

3 1

1 4

5 3

64 4.5 6.7 16 9

0 4

4 1

3 5

4 6

2 1

1 2

7 8

73 6.7 8.9 0

1 2

0 0

0 1

5 5

4 1

5 1

4 3

7 39 8.9 11.2 0

0 2

0 0

0 1

6 5

2 1

1 2

0 11 4

35 11.2 13.4 1

0 0

1 0

0 4

7 2

3 2

1 3

4 0

3 31 13.4 17.9 0

0 0

0 0

0 0

6 4

7 2

1 0

3 4

1 28 17.9 22.4 0

0 0

0 0

0 0

0 2

2 2

0 1

4 1

2 14 22.4 29.1 0

0 0

0 0

0 0

1 2

1 3

0 1

4 0

0 12 29.1 40.3 0

0 0

0 0

0 0

0 0

0 1

0 0

0 0

0 1

40.3 90.0 0

0 0

0 0

0 0

0 0

0 0

0 0

0 0

0 0

TOTALS 27 16 10 12 7

4 16 37 36 32 20 13 11 25 33 28 327 Stability Class:

G Wind Speed Min Max N

NNE NE ENE E

ESE SE SSE S

SSW SW WSW W

WNW NW NNW TOTAL 1.0 2.2 3

1 4

3 2

2 3

9 4

2 1

0 3

3 0

1 41 2.2 4.5 7

4 2

7 2

2 1

12 5

5 6

3 2

5 2

2 67 4.5 6.7 2

2 3

6 0

0 4

9 18 3

4 2

2 2

7 10 74 6.7 8,9 1

3 3

0 0

0 7

8 6

2 0

0 1

1 1

6 39 8.9 11.2 0

0 2

0 0

0 3

3 3

2 1

0 0

0 8

3 25 11.2 13.4 0

0 0

0 0

0 2

4' 2

0 2

0 1

1 3

4 19 13.4 17.9 0

0 0

0 0

0 0

1 0

0 1

0 0

2 5

2 11 17.9 22.4 0

0 0

0 0

0 0

0 1

0 4

0 0

1 3

0 9

22.4 29.1 0

0 0

0 0

0 0

0 0

0 0

0 0

0 0

0 0

29.1 40.3 0

0 0

0 0

0 0

0 0

0 0

0 0

0 0

0 0

40.3 90.0 0

0 0

0 0

0 0

0 0

0 0

0 0

0 0

0 0

TOTALS 13 10 14 16 4

4 20 46 39 14 19 5

9 15 29 28 285 Stability Class:

All Wind Speed Min Max N

NNE NE ENE E

ESE SE SSE S

SSW SW WSW W

WNW NW NNW TOTAL 1.0 2,2 13 10 11 9

7 6

11 25 15 11 9

8 8

14 12 12 181 2.2 4.5 31 26 14 15 10 11 14

29.

30 17 20 13 8

21 20 22 301 4.5 6.7 26 20 7

13 6

3 20 34 33 19 14 16 10 16 33 37 307 6.7 8,9 5

6 8

2 0

1 20 31 26 15 7

15 9

16 24 25 210 8.9 11.2 3

1 5

1 0

1 10 37 30 16 6

2 12 11 36 13 184 11.2 13.4 1

0 0

1 0

0 8

29 17 5

6 2

10 12 11 10 112 13.4 17.9 0

0 0

0 0

2 3

13 30 29 9

5 4

13 16 6

130 17.9 22.4 0

0 0

0

- 0 0

0 4

21 25 15 3

8 17 8

4 105 22.4 29.1 0

0 0

0 0

0 1

2 10 22 23 4

2 26 2

0 92 29.1 40.3 0

0 0

0 0

0 0

0 4

15 7

4 3

1 0

0 34 40.3 90.0 0

0 0

0 0

0 0

0 0

0 0

1 0

0 0

0 1

TOTALS 79 63 45 41 23 24 87 204 216 174 116 73 74 147 162 129 1657 Periods of Calm while in Stability Class:

A E3 C

D E

F G

Total 0

0 1

105 39 26 38 209 Coumi GeeaigSain3I01RaiatvdfletRpr Columbia Generating Station 37 2011 Radioactive Effluent Report

Table 5-9 Year 2011, 33 Ft AGL Hours at each wind speed and direction during time period Elevation:

33 Start Date:

1/1/2011 Total number of Periods: 8759 Period: Annual Stop Date:

1/11/20112 Periods of No Data Recovery: 764 System Percent Data Recovery: 91.3%

Stability Class:

A Wind Speed Min Max IN NNE NE ENE E

ESE SE SSE S

SSW SW WSW W

WNW NW NNW TOTAL 1.0 2.2 0

0 0

0 0

0 0

0 0

0 0

0 0

0 0

0 0

2.2 4.5 0

1 0

0 0

0 0

0 0

0 0

0 0

0 0

2 3

4.5 6.7 3

1 0

0 0

0 0

0 1

0 0

1 0

0 2

4 12 6.7 8.9 2

7 0

0 0

0 0

1 1

0 0

0 1

0 0

1 13 8.9 11.2 4

3 0

0 0

0 0

3 3

1 0

1 1

0 0

3 19 11.2 13.4 2

0 0

0 0

0

.0 2

7 1

0 1

0 0

0 0

13 13.4 17.9 6

0 0

0 0

0 0

5 14 4

3 0

1 1

0 1

35 17.9 22.4 0

0 0

0 0

0 0

0 3

1 5

3 1

1 2

1 17 22.4 29.1 0

0 0

0 0

0 0

0 0

0 0

0 1

1 0

1 3

29.1 40.3 0

0 0

0 0

0 0

0 0

0 0

0 0

0 0

0 0

40.3 90.0 0

0 0

0 0

0 0

0 0

0 0

0 0

0 0

0 0

ITOTALS, 17 12 0

0 0

0 0

11t 29 7

8 6

5 3

4 13 115 Stability Class:

B Wind Speed Min Max IN NNE NE ENE E

ESE SE SSE S

SSW SW WSW W

WNW NW NNW TOTAL 1.0 2.2 0

0 0

0 0

0 0

0 0

0 0

0 0

1 0

1 2.2 4.5 5

3 2

1 0

3 0

1 0

0 0

0 0

0 5

8 28 4.5 6.7 10 6

0 0

1 2

1 6

2 1

5 2

0 2

2 11 51 6.7 8.9 5

2 1

1 1

4 4

14 6

1 3

0 1

1 0

6 50 8.9 11.2 8

3 1

1 0

1 1

15 13 5

1 2

1 0

1 2

55 11.2 13.4 2

1 0

0 0

0 0

9 16 4

0 1

0 0

1 1

35 13.4 17.9 4

0 0

0 0

0 1

2.11 4

4 2

1 2

2 1

34 17.9 22.4 0

0 0

0 0

0 0

1 0

8 4

2 1

3 0

1 20 22.4 29.1 0

0 0

0 0

0 0

0 1

2 2

0 0

2 1

2 10 29.1 40.3 0

0 0

0 0

0 0

0 0

0 0

0 0

0 0

0 0

40.3 90.0 0

0 0

0 0

0 0

0 0

0 0

0 0

0 0

0 0

ITOTALS 34 15 4

3 2

10 7

48 49 25 19 9

4 11 12 33 28 Stability Class:

C Wind Speed Min Max N

NNE NE ENE E

ESE SE SSE S

SSW SW WSW W

WNW NW NNW TOTAL 1.0 2.2 10 7

3 6

4 2

2 1

1 0

2 3

1 2

1 12 57 2.2 4.5 16 11 13 26 16 16 11 11 10 6

2 7

2 4

23 21 195 4.5 6.7 10 5

9 7

3 9

14 26 17 8

6 13 5

2 4

21 159 6.7 8.9 6

10 1

5 7

3 8

36 25 5

8 7

3 9

5 9

147 8.9 11.2 4

1 1

1 0

1 1

14 23 9

1 4

3 5

4 10 82 11.2 13.4 2

0 0

0 0

0 0

5 21 13 2

3 6

5 4

3 64 13.4 17.9 3

0 0

0 0

0 1

5 28 17 4

8 6

8 8

3 91 17.9 22.4 1

0 0

0 0

0 0

2 3

9 7

3 3

4 2

3 37 22.4 29.1 0

0 0

0 0

0 0

0 0

2 1

1 0

4 0

0 8

29.1 40.3 0

0 0

0 0

0 0

0 0

0 0

0 0

0 0

0 0

40.3 90.0 0

0 0

0 0

0 0

0 0

0 0

0 0

0 0

0 0

ITOTALS 52 34 27 45 30 31 37 100 128 69 33 49 29 43 51 82 84 Stability Class:

D Wind Speed Min Max N

NNE NE ENE E

ESE SE SSE S

SSW SW WSW W

WNW NW NNW TOTAL 1.0 2.2 24 15 23 25 32 21 23 17 14 14 13 9

14 15 20 29 308 2.2 4.5 18 29 31 28 44 28 52 55 26 20 17 17 19 29 42 33 488 4.5 6.7 6

13 12 16 20 20 44 46 26 15 12 6

16 31 36 30 349 6.7 8.9 11 8

8 6

8 22 35 54 39 12

.8 13 16 18 24 19 3.01 8.9 11.2 11 1

4 0

0 1

16 33 35 13 9

6 12 27 29 15 212 11.2 13.4 3

0 0

0 0

0 6

16 36 21 6

8 12 25 13 7

153 13.4 17.9 2

1 0

0 0

0 1

18 35 40 21 13 13 49 19 5

217 17.9 22.4 0

0 0

0 0

0 1

2 9

27 12 11 8

24 8

0 102 22.4 29.1 0

0.

0 0

0 0

0 0

0 13 5

1 0

3 0

0 22 29.1 40.3 0

0 0

0 0

0 0

0 0

3 2

0 0

0 0

0 5

40.3 90.0 0

0 0

0 0

0 0

0 0

0 0

0 0

0 0

0 0

ITOTALS 75 67 78 75 104 92 178 241 220 178 105 84 110 221 191 138 215 Columbia Generating Station

38.

2011 Radioactive Effluent Report

Table 5-9 Year 2011, 33 Ft AGL (Continued)

Stability Class:

E Wind Speed Min Max N

NNE NE ENE E

ESE SE SSE S

SSW SW WSW W

WNW NW NNW TOTAL 1.0 2.2 14 13 15 8

8 5

7 16 14 16 9

7 4

18 12 14 180 2.2 4.5 10 16 16 6

10 14 30 37 23 29 21 18 30 28 37 40 365 4.5 6.7 6

8 10 2

3 13 31 41 24 21 24 22 26 41 43 26 341 6.7 8.9 3

3 8

0 0

6 39 43 23 10 15 11 21 33 39 14 268 8.9 11.2 0

0 1

0 0

5 19 53 25 20 9

9 19 47 30 8

245 11.2 13.4 0

0 1

0 0

2 6

40 19 26 5

9 16 41 15 3

183 13.4 17.9 0

0 0

0 0

0 6

16 38 37 24 5

6 38 7

2 179 17.9 22.4 0

0 0

0 0

0 0

1 10 26 9

3 4

4 0

0 57 22.4 29.1 0

0 0

0 0

0 0

0 3

21 3

2 1

0 0

0 30 29.1 40.3 0

0 0

0 0

0 0

0 0

1 0

0 0

0 0

0 1

40.3 90.0 0

0 0

0 0

0 0

0 0

0 0

0 0

0 0

0 0

ITOTALS 33 40 51 16 21 45 138 247 179 207 119 86 127 250 183 107 14 Stability Class:

F Wind Speed Min Max N

NNE NE ENE E

ESE SE SSE S

SSW SW WSW W

WNW NW NNW TOTAL 1.0 2.2 15 22 13 7

9 9

13 19 13 14 11 5

11 13 21 18 213 2.2 4.5 16 35 23 4

1 13 45 44 37 23 11 16 12 32 60 35 407 4.5 6.7 12 4

14 2

0 2

40 69 26 21 19 9

9 23 56 18 324 6.7 8.9 0

1 4

0 0

1 19 49 28 15 7

4 4

17 23 3

175 8.9 11.2 0

0 2

0 0

0 6

27 16 8

4 5

7 13 10 0

98 11.2 13.4 0

0 0

0 0

0 1

10 4

9 1

0 2

2 1

0 30 13.4 17.9 0

0 0

0 0

0 3

1 6

12 0

0 0

0 0

0 22 17.9 22.4 0

0 0

0 0

0 0

0 0

3 0

0 0

0 0

0 3

22.4 29.1 0

0 0

0 0

0 0

0 0

0 0

0 0

0 0

0 0

29.1 40.3 0

0 0

0 0

0 0

0 0

0 0

0 0

0 0

0 0

40.3 90.0 0

0 0

0 0

0 0

0 0

0 0

0 0

0 0

0 0

ITOTALS 43 62 56 13 10 25 127 219 130 105 53 39 45 100 171 74 17 Stability Class:

G Wind Speed Min Max N

NNE NE ENE E

ESE SE SSE S

SSW SW WSW W

WNW NW NNW TOTAL 1.0 2.2 21 27 26 6

5 10 15 7

7 8

3 10 12 20 26 32 235 2.2 4.5 28 30 31 1

1 1

25 35 17 7

8 14 8

10 48 31 295 4.5 6.7 4

2 17 1

0 0

24 38 9

12 2

2 1

6 26 16 160 6.7 8.9 0

0 2

0 0

0 6

22 5

3 9

0 0

3 13 4

67 8.9 11.2 0

0 0

0 0

0 0

6 1

4 1

1 0

0 0

0 13 11.2 13.4 0

0 1

0 0

0 0

5 0

2 0

0 0

0 0

0 8

13.4 17.9 0

0 0

0 0

0 0

3 0

1 0

0 0

0 0

0 4

17.9 22.4 0

0 0

0 0

0 0

0 0

0 0

0 0

0 0

0 0

22.4 29.1 0

0 0

0 0

0 0

0 0

0 0

0 0

0 0

0 0

29.1 40.3 0

0 0

0 0

0 0

0 0

0 0

0 0

0 0

0 0

40.3 90.0 0

0 0

0 0

0 0

0 0

0 0

0 0

0 0

0 0

ITOTALS 53 59 77 8

6 11 70 116 39 37 23 27 21 39 113 83 78 Stability Class:

All Wind Speed Min Max N

NNE NE ENE E

ESE SE SSE S

SSW SW WSW W WNW NW NNW TOTAL 1.0 2.2 84 84 80 52 58 47 60 60 49 52 38 34 42 69 80 106 995 2.2 4.5 93 125 116 66 72 75 163 183 113 85 59 72 71 103 215 170 1781 4.5 6.7 51 39 62 28 27 46 154 226 105 78 68 55 57 105 169 126 1396 6.7 8.9 27 31 24 12 16 36 111 219 127 46 50 35 46 81 104 56 1021 8.9 11.2 27 8

9 2

0 8

43 151 116 60 25 28 43 92 74 38 724 11.2 13.4 9

1 2

0 0

2 13 87 103 76 14 22 36 73 34 14 486 13.4 17.9 15 1

0 0

0 0

12 50 132 115 56 28 27 98 36 12 582 17.9 22.4 1

0 0

0 0

0 1

6 25 74 37 22 17 36 12 5

236 22.4 29.1 0

0 0

0 0

0 0

0 4

38 11 4

2 10 1

3 73 29.1 40.3 0

0 0

0 0

0 0

0 0

4 2

0 0

0 0

0 6

40.3 90.0 0

0 0

0 0

0 0

0 0

0 0

0 0

-0 0

0 0

ITOTALS 307 289 293 160 173 214 557 982 774 628 360 300 341 667 725 530 7300 Perids f Clm. hil inStability Class:

A B

C 0

E F

G Total Coumi Geeatn Staio 390 2011 Raioctv Effuen Repor Columbia Generating Station 39 2011 Radioactive Effluent Report

Table 5-10 Year 2011, 245 Ft AGL Hours at each windspeed and direction durhg lime perod Elevation: 245 Start Date:

1/11/2010 Total number of Periods: 8759 Period: Annual StopDate: 12/31/2010 Perods of No Data Recovery:

272 System Percent Data Recovery: 96.9%

Stability Class:

A Wind Speed Min Max N

NNE NE ENE E

ESE SE SSE S

SSW SW WSW W

WNW NW NNW TOTAL 1.0 2.2 0

0 0

0 0

0 0

0 0

0 0

0 0

0 0

0 0

2.2 4.5 1

0 0

0 0

0 0

1 0

0 0

0 0

0 0

1 3

4.5 6.7 0

0 0

1 0

0 0

0 0

0 0

0 0

0 0

0 1

6.7 8.9 2

0 0

0 0

0 0

0 0

0 0

0 0

0 0

0 2

8.9 11.2 1

0 0

0 0

0 0

1 0

0 0

0 0

0 0

4 6

11.2 13.4 7

2 0

0 0

0 0

0 4

0 0

0 0

0 0

2 15 13.4 17.9 0

3 2

0 0

0 0

0 7

3 0

0 0

0 2

2 19 17.9 22.4 0

2 0

0 0

0 0

0 1

3 2

0 0

0 2

0 10 22.4 29.1 0

0 0

0 0

0 0

0 0

1 0

0 2

2 1

0 6

29.1 40.3 0

0 0

0 0

0

.0 0

0 0

1 0

0 8

3 0

12 40.3 90.0 0

0 0

0 0

0 0

0 0

0 0

1 4

0 0

0 5

TOTALS 11 7

2 1

0 0

0 2

12 7

3 1

6 10 8

9 79 Stability Class:

B Wind Speed Min Max N

NNE NE ENE E

ESE SE SSE S

SSW SW WSW W

WNW NW NNW TOTAL 1.0 2.2 0

0 1

0 0

0 0

0 0

1 1

0 0

0 0

0 3

2.2 4.5 4

1 0

0 1

0 1

0 1

0 0

1 0

0 0

1 10 4.5 6.7 3

1 0

0 0

0 0

0 0

0 0

1 0

1 0

6 12 6.7 8.9 6

8 1

0 0

0 0

0 1

2 0

0 0

0 2

3 23 8.9 11.2 5

4 1

0 0

0 0

2 5

1 1

0 2

0 1

11 33 11.2 13.4 3

4 2

0 0

0 0

0 5

6 0

0 1

1 0

0 22 13.4 17.9 2

3 1

0 0

0 0

1 9

4 3

1 1

2 6

2 35 17.9 22.4 1

1 0

0 0

0 1

0 1

6 3

3 0

2 1

0 19 22.4 29.1 0

0 0

0 0

0 0

0 0

1 1

0 0

1 0

0 3

29.1 40.3 0

0 0

0 0

0 0

0 0

1 1

2 0

1 2

0 7

40.3 90.0 0

0 0

0 0

0 0

0 0

0 0

1 0

1 0

0 2

TOTALS 24 22 6

0 1

0 2

3 22 22 10 9

4 9

12 23 169 Stability Class:

C Wind Speed Min Max N

NNE NE ENE E

ESE SE SSE S

SSW SW WSW W

WNW NW NNW TOTAL 1.0 2.2 5

1 1

0 0

1 0

1 0

2 1

1 0

0 5

2 20 2.2 4.5 20 15 9

3 0

0 2

1 6

2 4

2 0

3 5

21 93 4.5 6.7 11 11 9

7 1

2 1

9 14 9

2 1

3 2

8 21 111 6.7 8.9 21 17 3

2 1

1 6

21 18 7

2 10 7

4 6

25 151 8.9 11.2 12 11 4

3 1

2 2

10 23 7

2 3

3 1

3 10 97 11.2 13.4 8

4 1

0 3

0 0

0 21 16 9

2 8

2 0

6 80 13.4 17.9 6

2 2

2 5

1 3

4 18 26 9

5 8

8 2

6 107 17.9 22.4 1

0 0

0 0

0 1

0 1

10 14 2

3 6

3 3

44 22.4 29.1 0

0 0

0 0

0 0

0 0

3 4

3 0

1 2

1 14 29.1 40.3 0

0 0

0 0

0 0

0 0

0 1

0 1

2 2

0 6

40.3 90.0 0

0 0

0 0

0 0

0 0

1 0

0 1

1 0

0 3

TOTALS 84 61 29 17 11 7

15 46 101 83 48 29 34 30 36 95 726 Stability Class:

D Wind Speed Min Max N

NNE NE ENE E

ESE SE SSE S

SSW SW WSW W

'WNW NW NNW TOTAL 1.0 2.2 12 12 24 17 13 10 13 8

17 13 6

10 3

9 10 13 190 2.2 4.5 36 28 41 22 12 10 32 63 35 25 29 18 20 19 28 43 461 4.5 6.7 22 23 39 20 8

16 46 62 45 21 19 16 14 16 21 48 436 6.7 8.9 15 27 24 21 8

8 21 41 48 18 16 20 7

10 33 34 351 8.9 11.2 8

12 9

14 4

7 29 24 40 25 13 14 7

17 37 25 285 11.2 13.4 12 9

4 4

4 6

10 12 35 21 10 6

5 24 46 32 240 13.4 17.9 24 3

4 0

3 4

18 24 38 32 21 13 12 31 37 21 285 17.9 22.4 1

3 3

0 0

2 5

4 10 41 12 5

7 26 16 16 151 22.4 29.1 0

0 0

0 0

2 0

4 6

29 22 8

10 32 25 3

141 29.1 40.3 0

0 0

0 0

0 0

0 0

12 15 3

6 34 11 0

81 40.3 90.0 0

0 0

0 0

0 0

0 0

0 0

0 0

0 0

0 0

TOTALS 130 117 148 98 52 65 174 242 274 237 163 113 91 218 264 235 2621 Columbia Generating Station 40 2011 Radioactive Effluent Report Columbia Generating Station 40 2011 Radioactive Effluent Report

Table 5-10 Year 2011, 245 Ft AGL (Continued)

Stability Class:

E Wind Speed Min Max N

NNE NE ENE E

ESE SE SSE S

SSW SW WSW W

WNW NW NNW TOTAL 1.0 2.2 8

5 6

4 5

3 7

8 3

  • 8 4

1 2

5 3

3 75 2.2 4.5 15 14 14 11 13 12 15 16 19 10 11 15 9

18 13 10 215 4.5 6.7 15 12 8

7 5

6 12 20 13 9

12 18 16 14 23 18 208 6.7 8.9 8

5 9

4 1

5 15 22 17 12 12 13 16 24 21 11 195 8.9 11.2 5

4 9

4 2

5 12 31 22 19 10 11 21 29 29 18 231 11.2 13.4 7

1 5

0 0

2 10 21 30 11 10 5

14 32 23 16 187 13.4 17.9 4

0 0

2 2

6 10 18 61 44 19 13 16 48 44 30 317 17.9 22.4 1

0 0

0 0

0 1

9 37 44 27 7

10 78 27 7

248 22.4 29.1 2

0 0

0 0

0 1

1 15 43 30 12 3

58 8

1 174 29.1 40.3 0

0 0

0 0

0 0

0 4

31 17 6

4 3

0 0

65 40.3 90.0 0

0 0

0 0

0 0

0 0

1 0

1 0

0 0

0 2

TOTALS 65 41 51 32 28 39 83 146 221 232 152 102 111 309 191 114 1917 Stability Class:

F Wind Speed Min Max N

NNE NE ENE E

ESE SE SSE S

SSW SW WSW W

WNW NW NNW TOTAL 1.0 2.2 3

3 10 6

6 11 5

11 10 10 9

6 "2

5 5

4 106 2.2 4.5 25 14 11 15 7

6 21 11 24 14 17 13 10 12 22 20 242 4.5 6.7 35 26 9

10 7

10 16 27 19 15 11 10 12 13 22 22 264 6.7 8.9 4

6 7

8 1

4 8

28 23 10 8

17 7

13 17 19 180 8.9 11.2 5

4 9

1 0

2 6

27 27 14 9

4 8

9 28 12 165 11.2 13.4 2

0 4

4 1

0 13 21 15 18 10 4

9 14 12 9

136 13.4 17.9 2

0 0

1 0

0 4

21 25 27 8

5 10 34 28 12 177 17.9 22.4 0

0 0

0 0

0 0

1 8

14 11 2

3 21 6

4 70 22.4 29.1 0

0 0

0 0

0 0

1 5

3 5

0 2

6 0

0 22 29.1 40.3 0

0 0

0 0

0 0

0 0

6 2

0 0

0 0

0 8

40.3 90.0 0

0 0

0 0

0 0

0 0

0 0

0 0

0 0

0 0

TOTALS 76 53 50 45 22 33 73 148 156 131 90 61 63 127 140 102 1370 Stability Class:

G Wind Speed Min Max N

NNE NE ENE E

ESE SE SSE S

SSW SW WSW W

WNW NW NNW TOTAL 1.0 2.2 10 4

7 5

6 6

8 19 7

7 4

4 6

5 3

5 106 2.2 4.5 21 16 11 12 6

11 14 24 16 13 12 8

3 9

10 11 197 4.5 6.7 17 16 8

7 6

6 20 24 32 11 11 6

4 3

12 24 207 6.7 8.9 10 18 10 2

1 3

16 25 20 18 5

4 2

4 4

22 164 8.9 11.2 3

2 7

6 0

0 5

16 9

9 4

3 0

1 17 17 99 11.2 13.4 0

0 0

2 0

0 5

15 4

6 5

0 1

2 12 16 68 13.4 17.9 0

0 0

0 0

0 1

6 7

3 3

0 3

7 9

3 42 17.9 22.4 0

0 0

0 0

0 0

0 4

0 4

0 1

3 4

0 16 22.4 29.1 0

0 0

0 0

0 0

0 1

2 0

0 0

0 0

0 3

29.1 40.3 0

0 0

0 0

0 0

0 0

0 0

0 0

0 0

0 0

40.3 90.0 0

0 0

0 0

0 0

0 0

0 0

0 0

0 0

0 0

TOTALS 61 56 43 34 19 26 69 129 100 69 48 25 20 34 71 98 902 Stability Class:

All Wind Speed Min Max N

NNE NE ENE E

ESE SE SSE S

SSW SW WSW W

WNW NW NNW TOTALI 1.0 2.2 4.5 6.7 8.9 11.2 13.4 17.9 22.4 29.1 40.3 2.2 38 30 4.5 104 78 6.7 100 81 8.9 46 53 11.2 42 26 13.4 28 3

17.9 23 7

22.4 4

3 29.1 5

0 40.3 0

0 90.0 0

0 41 70 41 41 32 15 0

0 0

0 0

34 84 51 33 18 7

3 0

0 0

0 41 76 43 17 12 4

2 0

0 0

0 31 35 56 37 41 29 24 19 35 28 32 551 68 88 101 94 54 62 50 36 64 86 89 1204 60 88 136 100 70 51 58 46 50 94 121 1190 32 68 141 130 62 39 57 48 53 87 90 997 34 39 132 144 81 35 35 48 68 99 74 919 19 38 82 104 67 37 23 38 62 76 63 666 7

24 63 208 177 57 35 56 135 107 63 967 0

1 13 82 122 73 27 35 138 67 21 586 0

1 5

28 88 81 33 20 113 31 6

411 0

0 0

4 51 35 8

5 12 3

0 118 0

0 0

0 1

0 1

0 0

0 0

2 TOTALS 390 281 240 230 195 251 382 729 931 814 499 351 351 730 678 559 7611 Periods of Calm while in Stability Class:

A B

C D

E F

G Total 0 1 12 169 63 63 76 384 Columbia Generating Station 41 2011 Radioactive Effluent Report

Table 5-11 Year 2011 Growing Season - Daylight Hours (Solar Irradiance > 5 watts/m2; 33 Ft AGL)

Hours at each wind speed and direction during time period FElevation:

33 Start Date:

4/15/2011 Total number of Periods: 2647 Period: Growing season Stop Date:

10/16/2011 Periods of No Data Recovery:

307 Daylight hours System Percent Data Recovery: 88.4%

Stability Class:

A Wind Speed Min Max N

NNE NE ENE E

ESE SE SSE S

SSW SW WSW W

WNW NW NNW TOTAL 1.0 2.2 0

0 0

0 0

0 0

0 0

0 0

0 0

0 0

0 0

2.2 4.5 0

1 0

0 0

0 0

0 0

0 0

0 0

0 0

0 1

4.5 6.7 2

0 0

0 0

0 0

0 0

0 0

0 0

0 1

2 5

6.7 8.9 2

3 0

0 0

0 0

0 1

0 0

0 2

0 1

1 10 8.9 11.2 6

4 1

0 0

0 0

0 1

2 0

0 0

0 0

3 17 11.2 13.4 0

2 0

0 0

0 0

2 5

0 0

1 1

0 0

0 11 13.4 17.9 6

0 0

0 0

0 0

0 16 5

0 1

0 0

0 0

28 17.9 22.4 0

0 0

0 0

0 0

0 6

7 2

1 0

2 0

2 20 22.4 29.1 0

0 0

0 0

0 0

0 0

1 5

1 2

1 1

0 11 29.1 40.3 0

0 0

0 0

0 0

0 0

0 0

0 0

1 0

0 1

40.3 90.0 0

0 0

0 0

0 0

0 0

0 0

0 0

0 0

0 0

TOTALS 16 10 1

0 0

0 0

2 29 15 7

4 5

4 3

8 104 Stability Class:

B Wind Speed Min Max N

NNE NE ENE E

ESE SE SSE S

SSW SW WSW W

WNW NW, NNW TOTAL 1.0 2.2 0

0 0

0 0

0 0

0 0

0 0

0 0

0 0

1 1

2.2 4.5 5

1 1

2 0

1 0

1 0

0 0

0 0

0 2

3 16 4.5 6.7 12 5

0 0

0 1

0 3

0 2

0 1

0 0

1 8

33 6.7 8.9 7

5 1

1 0

2 2

2 6

1 0

4 3

0 1

1 36 8.9 11.2 1

4 1

1 1

3 2

8 13 3

3 0

1 1

0 3

45 11.2 13.4 2

0 1

0 0

2 2

4 17 5

3 2

0 1

1 0

40 13.4 17.9 2

0 0

0 0

0 0

2 20 9

1 1

0 0

0 2

37 17.9 22.4 0

0 0

0 0

0 0

0 2

0 5

1 1

2 2

0 13 22.4 29.1 0

0 0

0 0

0 0

0 0

1 6

1 0

4 1

0 13 29.1 40.3 0

0 0

0 0

0 0

0 0

0 1

0 0

1 0

0 2

40.3 90.0 0

0 0

0 0

0 0

0 0

0 0

0 0

0 0

0 0

TOTALS 29 15 4

4 1

9 6

20 58 21 19 10 5

9 8

18 236 Stability Class:

C Wind Speed Min Max N

NNE NE ENE E

ESE SE SSE S

SSW SW WSW W

WNW NW NNW TOTAL 1.0 2.2 3

3 0

2 6

1 0

2 1

0 1

0 1

2 2

3 27 2.2 4.5 12 9

7 18 13 10 3

7 9

3 2

5 6

4 6

7 121 4.5 6.7 5

7 3

9 10 14 12 14 13 10 3

9 1

2 6

5 123 6.7 8.9 4

7 5

7 3

5 4

30 19 8

7 8

4 0

7 4

122 8.9 11.2 4

4 1

2 2

5 3

10 29 6

3 3

7 7

1 3

90 11.2 13.4 1

0 0

1 3

4 0

4 12 6

2 2

3 3

2 2

45 13.4 17.9 1

1 0

0 0

0 0

2 16 14 5

3 6

8 2

0 58 17.9 22.4 0

0 0

0 0

0 0

0 4

6 3

3 3

4 5

1 29 22.4 29.1 0

0 0

0 0

0 0

0 1

2 3

0 1

4 2

0 13 29.1 40.3 0

0 0

0 0

0 0

0 0

0 0

1 0

1 1

0 3

40.3 90.0 0

0 0

0 0

0 0

0 0

0 0

0 0

0 0

0 0

TOTALS 30 31 16 39 37 39 22 69 104" 55 29 34 32 35 34 25 631 Stability Class:

D Wind Speed Min Max N

NNE NE ENE E

ESE SE SSE S

SSW SW WSW W

WNW NW NNW TOTAL 1.0 2.2 3

4 7

11 11 7

9 6

5 2

3 4

1 2

1 2

78 2.2 4.5 6

10 10 20 31 16 25 23 12 6

8 5

2 6

5 5

190 4.5 6.7 3

6 8

15 14 21 16 23 9

12 5

5 5

4 5

2 153 6.7 8.9 3

3 6

11 11 13 15

. 16 25 6

4 8

7 6

9 3

146 8.9 11.2 1

2 3

3 6

17 6

12 17 11 3

5 5

4 1

5 101 11.2 13.4 1

0 1

0 0

11 8

4 4

10 3

4 7

2 4

2 61 13.4 17.9 0

0 0

0 0

1 5

4 13 15 5

5 14 8

8 3

81 17.9 22.4 0

0 0

0 0

0 0

1 4

6 7

6 6

11 10 1

52 22.4 29.1 0

0 0

0 0

0 0

0 2

0 6

9 3

17 11 0

48 29.1 40.3 0

0 0

0 0

0 0

0 0

0 0

0 1

3 1

0 5

40.3 90.0 0

0 0

0 0

0 0

0 0

0 0

0 0

0 0

0 0

TOTALS 17 25 35 60 73 86 84 89 91 68 44 51 51 63 55 23 915 Columbia Generating Station 42 2011 Radioactive Effluent Report

Table 5-11 Year 2011 Growing Season - Daylight Hours (Continued)

(Solar Irradiance > 5 watts/m 2; 33 Ft AGL)

Stability Class:

E Wind Speed Min Max N

NNE NE ENE E

ESE SE SSE S

SSW SW WSW W

WNW NW NNW TOTAL 1.0 2.2 1

0 3

1 1

0 1

1 0

0 0

0 0

0 0

0 8

2.2 4.5 1

2 1

2 3

2 4

3 3

1 1

0 0

1 1

3 28 4.5 6.7 0

3 0

0 3

2 4

5

.4 1

1 3

0 1

1 2

30 6.7 8.9 3

3 2

1 0

2 5

3 5

3 1

0 0

1 1

0 30 8.9 11.2 0

1 2

2 2

4 2

5 5

4 0

2 2

1 4

1 37 11.2 13.4 2

1 0

0 0

2 2

3 6

1 4

1 1

0 2

0 25 13.4 17.9 0

0 0

0 0

3 3

1 5

3 2

1 1

1 5

3 28 17.9 22.4 0

0 0

0 0

0 0

1 3

1 2

0 0

1 1

0 9

22.4 29.1 0

0 0

0 0

0 0

0 0

0 0

0 0

3 0

0 3

29.1 40.3 0

0 0

0 0

0 0

0 0

0 0

0 0

0 0

0 0

40.3 90.0 0

0 0

0 0

0 0

0 0

0 0

0 0

0 0

0 0

TOTALS 7

10 8

6 9

15 21 22 31 14 11 7

4 9

15 9

198 Stability Class:

F Wind Speed Min Max N

NNE NE ENE E

ESE SE SSE S

SSW SW WSW W

WNW NW NNW TOTAL 1.0 2.2 0

0 2

1 0

1 0

0 1

0 1

1 1

0 0

0 8

2.2 4.5 3

1 2

3 1

0 3

3 3

1 2

0 1

1 1

0 25 4.5 6.7 1

1 2

1 0

3 3

3 4

5 0

0 3

0 0

0 26 6,7 8.9 0

0 0

1 1

0 0

3 2

2 2

3 0

1 0

2 17 8,9 11.2 1

1 1

0 0

0 0

2 2

2 0

0 0

0 0

1 10 11.2 13.4 0

0 0

0 0

0 0

4 2

1 1

1 0

0 0

0 9

13.4 17.9 0

0 0

0 0

0 0

2 2

0 1

0 1

1 2

0 9

17.9 22.4 0

0 0

0 0

0 0

0 0

0 1

0 0

0 1

0 2

22.4 29.1 0

0 0

0 0

0 0

0 0

0 0

0 0

0 0

0 0

29.1 40.3 0

0 0

0 0

0 0

0 0

0 0

0 0

0 0

0 0

40.3 90.0 0

0 0

0 0

0 0

0 0

0 0

0 0

0 0

0 0

TOTALS 5

3 7

6 2

4 6

17 16 11 8

5 6

3 4

3 106 Stability Class:

G Wind Speed Min Max N

NNE NE ENE E

ESE SE SSE S

SSW SW WSW W

WNW NW NNW TOTAL 1.0 2.2 1

0 0

0 1

2 0

4 0

1 0

0 0

1 0

0 10 2.2 4.5 0

1 1

1 1

3 1

2 3

1 1

1 0

0 0

0 16 4.5 6.7 2

0 0

0 1

1 2

3 2

1 1

2 0

0 0

0 15 6.7 8.9 0

1 0

1 0

0 0

2 1

2 2

1 0

0 1

2 13 8.9 11.2 0

0 0

0 0

0 0

5 1

0 0

0 0

0 0

2 8

11.2 13.4 0

0 0

0 0

0 0

1 0

2 0

0 0

0 1

1 5

13.4 17.9 0

0 0

0 0

0 0

1 0

0 0

0 0

0 0

0 1

17.9 22.4 0

0 0

0 0

0 0

0 0

0 0

0 0

0 0

0 0

22.4 29.1 0

0 0

0 0

0 0

0 0

0 0

0 0

0 0

0 0

29.1 40.3 0

0 0

0 0

0 0

0 0

0 0

0 0

0 0

0 0

40.3 90.0 0

0 0

0 0

0 0

0 0

0 0

0 0

0 0

0 0'

TOTALS 3

2 1

2 3

6 3

18 7

7 4

4 0

1 2

5 68 Stability Class:

All Wind Speed Min Max N

NNE NE ENE E

ESE SE SSE S

SSW SW WSW W

WNW NW NNW TOTAL 1.0 2.2 8

7 12 15 19 11 10 13 7

3 5

5 3

5 3

6 132 2.2 4.5 27 25 22 46 49 32 36 39 30 12 14 11 9

12 15 18 397 4.5 6.7 25 22 13 25 28 42 37 51 32 31 10 20 9

7 14 19 385 6.7 8.9 19 22 14 22 15 22 26 56 59 22 16 24 16 8

20 13 374 8.9 11.2 13 16 9

8 11 29 13 42 68 28 9

10 15 13 6

18 308 11.2 13.4 6

3 2

1 3

19 12 22 46 25 13 11 12 6

10 5

196 13.4 17.9 9

1 0

0 0

4 8

12 72 46 14 11 22 18 17 8

242 17.9 22.4 0

0 0

0 0

0 0

2 19 20 20 11 10 20 19 4

125 22.4 29.1 0

0 0

0 0

0 0

0 3

4 20 11 6

29 15 0

88 29.1 40.3 0

0 0

0 0

0 0

0 0

0 1

1 1

6 2

0 11 40.3 90.0 0

0 0

0 0

0 0

0 0

0 0

0 0

0 0

0 0

TOTALS 107 96 72 117 125 159 142 237 336 191 122 115 103 124 121 91 2258 Periods of Calm while in Stability Class:

A B

C D

E F

G Total 0

1 7

43 14 13 4

82 Columbia Generating Station 43 2011 Radioactive Effluent Report

6.0 DOSE ASSESSMENT -- IMPACT ON MAN' Liquid Effluents - There were no liquid discharges from the radwaste processing system to the Columbia River during calendar year 2011.

Gaseous Effluents - The NRC GASPAR II computer code was used to calculate doses at and beyond the site boundary using quarterly and annual meteorological data and site-specific variables as required and defined in the ODCM. Table 6-1 shows the highest calculated doses at the site boundary and beyond the site boundary. Table 6-1 also shows the quarterly and annual dose for the nearest and highest exposed resident identified in the land use census. Table 6-2 provides the population collective dose within a 50-mile radius. These values were obtained from the ALARA annual integrated population dose summary (in person-rem) of the GASPAR computer code output file. Table 6-2 also provides the annual average individual doses associated with each pathway. These values were obtained by dividing the ALARA integrated dose (person-rem) by the estimated year 2000 50-mile population (356,993) and converting to mrem.

During the growing season, Columbia Generating Station conducts a five-mile land use census to determine the locations of nearest residents, gardens, and milk animals or other livestock out to five miles in each sector. The 2011 Land Use Census did not identify broad leaf vegetable gardens or milk animals within the 5-mile radius. Cattle, goats, and horses were observed within 5-miles. Although it was not determined if the nearest residents were actually consuming meat from these animals, the beef and goat meat pathways were assumed in the sectors where these animals were observed. The NRC computer code GASPAR was used for dose estimates. IAEA Technical Series Report 4721 was used to derive Stable Element Transfer ratios to convert the GASPAR beef meat dose output to dose from goat meat. As substantial commercial fruit orchards and corn crops were observed in all eastern sectors with residents, it was assumed that these crops were being consumed by the residents. The GASPAR code consumption rates were revised to reflect these differences.

An estimate of Carbon-14 (14C) releases in units of Curies (Ci) was made based on thermal power generation in units of gigawatts-thermal (GWth).

14C Production Rate 5.1 +/- 0.6 Ci/GWth - yr Rated Thermal Power 3.486 GWth CGS Production Rate 17.8 +/- 2.1 Ci/yr at rated power GWth-hrs Ci of 1 4C Ci of 14CO 2 1st Quarter 7488.9 4.4 4.2 2nd Quarter 95.0 0.056 0.053 3rd Quarter 87.9 0.051 0.048 4th Quarter 7460.2 4.3 4.1 Total Year 2011 151 32.0 8.8 8.4 Growing Season 1205.8 1.4 1.3 Handbook Of Parameter Values For The Prediction Of Radionuclide Transfer In Terrestrial And Freshwater Environments, IAEA Technical Series Report 472, 2010 Columbia Generating Station 44 2011 Radioactive Effluent Report

The 14C production rate was estimated in Electric Power Research Institute (EPRI)

Technical Report 1021106 which also estimated that 95% of 14C production is released as 14CO2 As 14C in the form of 14C02 is a non-depositing, gaseous effluent, it enters the food chain through plant photosynthesis. Since Columbia Generating Station is a continuous release plant, normally, offsite dose is based on meteorological data throughout the year. For 14C dose analysis, however, a Joint Frequency Distribution (JFD) table of atmospheric data was developed based on daylight hours (solar irradiance > 5 watts per square meter) during the growing season of both vegetables and pasture grass for beef (April 15th through October 15th). The JFD table was used as input into the NRC XOQDOQ computer code from which dispersion estimates were obtained. This method provides a more accurate method of determining the average air concentration of 14002 during times of photosynthesis.

Both inhalation and ingestion pathways contribute to dose from 14C. The inhalation 14

~14 1

dose estimate assumes a full year 14C inhalation of both OH 4 and 14CO2. The ingestion pathway assumes 14C ingestion from 14002 incorporation into vegetation and meat during daylight hours of the growing season.

The highest dose calculated was for the resident at 4.24 miles in the ESE sector due to higher dispersion and deposition in that sector. The annual dose to the potential maximally exposed individual (child living at resident location 4.24 miles ESE) from gaseous releases of 14C is 5.34E-03 mrem to the critical organ (bone) and 1.06E-03 mrem to the total body. The available dose pathways at this location were inhalation and the ingestion of garden produce (fruits, grains, and non-leafy vegetables). Nearby sectors with beef and goat meat ingestion pathways had lower total body and bone dose due to lower dispersion values. Dose from 14C is only included in Table 6.0-C of this section.

For all other gaseous releases, the highest calculated dose to a child living at locations identified in the most recent land use census was 1.90E-03 mrem to the total body, 2.23E-03 mrem to the thyroid, and 2.88E-03 mrem to the skin. This location was at 4.24 miles in the East South East sector.

Periodically, Columbia Generating Station offers public tours of selected locations within the site boundary. Calculations assumed an eight (8) hour per year exposure to the plume, ground shine, and inhalation pathways. The organ with the highest dose was the skin at 5.41 E-04 mrem.

Columbia Generating Station 45 2011 Radioactive Effluent Report

During 2011, Members of the Public worked within the owner controlled area at the Industrial Development area in the E and ESE sectors and at the DOE 618-11 burial site in the W and WNW sectors. The maximum dose from gaseous effluents to these individuals was also estimated assuming adult exposure to the plume, inhalation, and ground deposition pathways.

The following table (6.0-A) shows estimated dose to Members of the Public from gaseous effluents and direct radiation exposure within the site boundary of Columbia Generating Station for the total indicated hours spent at each location.

Table 6.0-A; Estimated Dose to Members of the Public within the Site Boundary Total Body Thyroid Highest Other Beta Air Gamma Direct Hours Dose Dose Organ Dose Dose Air Dose Radiation Location Spent (mrem)

(mrem)

(mrem)

(mrad)

(mrad)

(mrem)

Tour Visitors 8.OOE+00 3.45E-04 3.65E-04 5.41E-04 1.72E-04 4.86E-04 1.35E-02 Firing Range 8.OOE+00 2.93E-06 2.95E-06 4.53E-O6 1.36E-06 3.84E-06 O.OOE+00 618-11 DOE Site 2.OOE+03 1.89E-03 1.93E-03 2.89E-03 8.56E-04 2.42E-03 6.19E+00 WNP-4Whse.2-4 2.60E+03 3.83E-03 3.88E-03 5.85E-03 1.70E-03 4.83E-03 O.OOE+00 WNP-1 Bldg 121 2.60E+03 1.11E-02 1.11E-02 1.71E-02 5.10E-03 1.45E-02 n.00E+OO Table 6.0-B provides the results of annual dose calculations for the highest dose age group for each identified land use census location from gaseous effluents. The highest 'Other Organ' in all cases was the skin.

Table 6.0-B; Estimated Dose to Residents identified in the 2011 Land Use Census Highest Total Body Thyroid Other Organ Beta Gamma Dose Dose Dose Air Dose Air Dose Age Location (mrem)

(mrem)

(mrem)

(mrad)

(mrad)

Group Resident (4.47 miles NE) 2.89E-04 3.91E-04 4.14E-04 1.10E-04 3.12E-04 Child Resident (4.01 miles ENE) 2.85E-04 3.88E-04 4.01E-04 1.04E-04 2.94E-04 Child Resident (4.59 miles E) 9.83E-04 1.15E-03 1.44E-03 4.03E-04 1.14E-03 Child Resident (4.65 miles E) 1.02E-03 1.18E-03 1.49E-03 4.16E-04 1.18E-03 Child Resident (4.24 miles ESE) 1.90E-03 2.23E-03 2.88E-03 8.60E-04 2.44E-03 Child Columbia GeneratingStation 46 2011 Radioactive Effluent Report

Based on the available exposure pathways and the highest dispersion and deposition values, the critical receptor is the resident at 4.24 miles ESE. Table 6.0-C adds the potential dose from Carbon-14 to the above dose estimate.

Table 6.0-C; Total Potential Dose to Critical Receptor (4.24 miles ESE)

Total Body Bone Thyroid Skin Dose from Carbon-14 1.06E-03 5.34E-03 1.06E-03 1.06E-03 Dose from Other Nuclides 1.90E-03 1.80E-03 2.23E-03 2.88E-03 Total Dose 2.96E-03 7.14E-03 3.29E-03 3.93E-03 For environmental thermoluminescent dosimeter (TLD) stations at or beyond the site boundary where preoperational (background) data was acquired, no increase in the average ambient exposure was observed in 2011 from the preoperational values.

Columbia Generating Station 47 2011 Radioactive Effluent Report Columbia Generating Station 4'7 2011 Radioactive Effluent Report

Dose Tables Dose from Carbon-14 is not included in these tables for reasons discussed earlier in this report.

Table 6-1 Summary of Doses from Gaseous Effluents The first six tables in this section show maximum estimated exposure and dose at and beyond the site boundary although no real person is resident at the site boundary. The maximum exposure and dose beyond the site boundary is estimated for locations with actual residents.

1. Maximum Air Dose at the Site Boundary (1.2 miles) 1 st 2nd 3rd 4th Annual Quarter Quarter Quarter Quarter Cumulative*

Beta air dose (mrad) 7.74E-03 2.74E-04 O.OOE+00 1.10E-03 7.35E-03 Gamma air dose (mrad) 2.19E-02 7.73E-04 O.OOE+00 3.12E-03 2.08E-02

2. Maximum Air Dose Beyond the Site Boundary 1 st 2nd 3rd 4th Annual Quarter Quarter Quarter Quarter Cumulative*

Beta air dose (mrad) 2.55E-04 3.01E-05 0.OOE+00 1.87E-04 8.60E-04 Gamma air dose (mrad) 7.22E-04 8.51 E-05 0.00E+00 5.31 E-04 2.44E-03

3. Maximum Annual Dose at the Site Boundary Annual Dose Annual total body dose (mrem)

[ 1.55E-02 Annual skin dose (mrem)

I 2.40E-02

4. Maximum Annual Dose Beyond the Site Boundary Annual Dose Annual total body dose (mrem) 1.90E-03 Annual skin dose (mrem) 2.88E-03 Columbia Generating Station 48 2011 Radioactive Effluent Report Columbia Generating Station 48 2011 Radioactive Effluent Report

Table 6-1 Summary of Doses from Gaseous Effluents (Continued)

5. Maximum Organ Dose at the Site Boundary (1.2 miles) 1 st 2nd 3rd 4th Ann ual Quarter Quarter Quarter Quarter Cumulative*

Maximum Organ dose (mrem) 2.37E-02 1.25E-03 1.13E-03 3.43E-03 2.40E-02

6. Maximum Organ Dose Beyond the Site Boundary 1 st 2nd 3rd 4th Ann ual Quarter Quarter Quarter Quarter Cu mulative*

Maximum Organ dose (mrem) 8.74E-04 1.59E-04 7.91 E-05 6.71_E-04 2.88E-03

7. Dose to Nearest Residents within 5-Miles in each Sector with Residents 4.47 Miles NE 1 st 2nd 3rd 4th Ann ual Quarter Quarter Quarter Quarter Cumulative*

Beta Air Dose (mrad) 1.17E-04 9.85E-06 0.OOE+00 2.65E-05 1.10E-04 Gamma Air Dose (mrad) 3.31 E-04 2.78E-05 0.00E+00 7.50E-05 3.12E-04 Maximum Organ dose (mrem) 3.90E-04 5.19E-05 2.48E-05 1.03E-04 4.14E-04 4.01 Miles ENE 1 st 2nd 3rd 4th Annual Quarter Quarter Quarter Quarter Cumulative*

Beta Air Dose (mrad) 2.13E-04 5.42E-06 0.OOE+00 4.41E-05 1.04E-04 Gamma Air Dose (mrad) 6.03E-04 1.53E-05 O.OOE+00 1.25E-04 2.94E-04 Maximum Organ dose (mrem) 6.78E-04 4.93E-05 3.30E-05 1.58E-04 4.01E-04 4.59 Miles E 1 st 2nd 3rd 4th Annual Quarter Quarter Quarter Quarter Cumulative*

Beta Air Dose (mrad) 2.49E-04 9.76E-06 O.OOE+00 3.12E-05 4.03E-04 Gamma Air Dose (mrad) 7.07E-04 2.75E-05 0.OOE+00 8.84E-05 1.14E-03 Maximum Organ dose (mrem) 8.52E-04 6.60E-05 4.80E-05 1.90E-04 1.44E-03 Columbia Generating Station 49 2011 Radioactive Effluent Report Columbia Generating Station 49 2011 Radioactive Effluent Report

Table 6-1 Summary of Doses from Gaseous Effluents (Continued)

7. Dose to Nearest Residents within 5-Miles in each Sector with Residents (Continued) 4.65 Miles E I st

-na 3rd 4tn Annual Quarter Quarter Quarter Quarter Cumulative*

Beta Air Dose (mrad) 2.55E-04 9.76E-06 0.00E+00 1.87E-04 4.16E-04 Gamma Air Dose (mrad) 7.22E-04 2.75E-05 O.OOE+00 5.31E-04 1.18E-03 Maximum Organ dose (mrem) 8.74E-04 '6.65E-05 4.59E-05 6.71 E-04 1.49E-03 4.24 Miles ESE 1 st 2nd 3rd 4th Annual Quarter Quarter Quarter Quarter Cumulative*

Beta Air Dose (mrad) 4.23E-05 3.01 E-05 0.00E+00 1.65E-04 8.60E-04 Gamma Air Dose (mrad) 1.20E-04 8.51 E-05 0.00E+00- 4.69E-04 2.44E-03 Maximum Organ dose (mrem) 4.77E-04 1.59E-04 7.91E-05 5.96E-04 2.88E-03

  • Rather than the sum of the quarters, the Annual Cumulative values are based on annual meteorological data and total annual effluents. For each time period, the dose estimate uses the radionuclide mix and release rate for that period along with an estimate of the dispersion in air and deposition on ground and vegetation calculated by the NRC computer code XOQDOQ using actual meteorological conditions during the respective quarters. The dose estimate of the NRC computer code GASPAR uses, as base methodology, NRC Regulatory Guide 1.109 (1974) which includes the prospective dose component arising from retention in the body beyond the period of environmental exposure.

Columbia Generating Station 50 2011 Radioactive Effluent Report

Table 6-2 50-Mile Population Dose from Gaseous Effluents A. 50-mile population collective dose Exposure Total Body Max. Organ Pathway (person-rem)

(person-rem)

Plume 2.65E-03 4.70E-03 Ground 1.04E-03 1.22E-03 Inhalation 1.64E-03 1.63E-03 Vegetables 1.79E-03 1.72E-03 Milk 7.11E-04 6.01E-04 Meat 3.42E-04 3.08E-04 Total 8.17E-03 1.02E-02 B. Average Individual*

Exposure Total Body Max. Organ Pathway (mrem)

(mrem)

Plume 7.42E-06 1.32E-05 Ground 2.91E-06 3.42E-06 Inhalation 4.59E-06 4.57E-06 Vegetables 5.01 E-06 4.82E-06 Milk 1.99E-06 1.68E-06 Meat 9.58E-07 8.63E-07 Total 2.29E-05 2.85E-05

  • These values are derived by dividing the 50-mile population collective doses by the population within 50 miles of Columbia Generating Station (356,993). The population estimate is based on the 2000 census conducted by the United States Census Bureau and documented in the Columbia Generating Station Final Safety Analysis Report. The Maximum Organ was the skin.

Columbia Generating Station 51 2011 Radioactive Effluent Report

7.0 REVISIONS TO THE ODCM One revision was made to the ODCM which involved Requirement For Operability 6.1.2 Radioactive Gaseous Effluent Monitoring Instrumentation. The previous revision only required one channel of the Offgas Post Treatment Radiation Monitors to be Operable and had Required Compensatory Actions to take if that one channel was Inoperable (Condition C). The Required Compensatory Measure was to take a noble gas grab sample every eight hours. The revision created Required Compensatory Measures to take if even one of the two available channels is not available. The revised Required Compensatory Measure ensures that the plant design described in the Final Safety Analysis Report Section 11.5.2.2.1.2 is maintained by verification that Inoperable channels are placed in a trip condition or by implementing administrative controls to prevent exceeding effluent limits. The frequency of noble gas grab samples for the Required Compensatory Measure was extended from once every eight hours to once every twelve hours consistent with the guidance of NUREG-1 302.

8.0 REVISIONS TO THE PROCESS CONTROL PROGRAM (PCP)

The Process Control Program, SWP-RMP-02 was changed in November 2011 to update the descriptions of the processing systems used to prepare spent resin for disposal. These changes were needed because the casks that were available to ship "Type B" resin, the processed RWCU resin for disposal, from our previous system lost their certification.

The frequency of the scaling factors, 10 CFR 61 required analysis was changed from annual to biennial, from every year to every two years to coincide with the Columbia Generating Station fuel cycle. The waste classification branch technical position (BTP) provided acceptable approaches for the development of facility and waste stream specific scaling factors. The guidance calls for reasonable efforts to be conducted for waste characterization. An acceptable sample frequency associated with these reasonable efforts was stated in the BTP as annually for Class B and Class C waste and every two years for Class A wastes. There is also some latitude to lengthen these sample frequencies based on plant conditions remaining stable. In practice, plant operations are typically conducted to minimize perturbations during the fuel cycle making changes in waste characteristics minimal during that time.

Columbia Generating Station 52 2011 Radioactive Effluent Report

9.0 NEW OR DELETED LOCATIONS FOR DOSE ASSESSMENTS AND/OR ENVIRONMENTAL MONITORING LOCATIONS 9.1 The 2011 Five-Mile Land Use Census showed no new pathways of exposure. The following table summarizes the assumed dose pathways:

Ingestion Plume Ground Inhalation Fruit or Beef Goat Location Shine Vegetation Meat Meat Resident (4.47 miles NE)

X X

X X

Resident (4.01 miles ENE)

X X

oX X

X Resident (4.59 miles E)

X X

X X

Resident (4.65 miles E)

X X

X X

X Resident (4.24 miles ESE)

X X

X X

9.2 There were no new locations for environmental monitoring formally adopted into the program based on the 2011 Land Use Census.

9.3 No dose assessment or environmental monitoring locations were deleted.

10.0 MAJOR CHANGES TO RADIOACTIVE LIQUID, GASEOUS, AND SOLID WASTE TREATMENT SYSTEMS No major changes (as defined by ODCM Section 6.4.3) were made to the radioactive waste systems (liquid, gaseous, or solid) during this reporting period.

Columbia Generating Station 53 2011 Radioactive Effluent Report Columbia Generating Station 53 2011 Radioactive Effluent Report