ML12032A151

From kanterella
Jump to navigation Jump to search
Technical Specification Bases Manual
ML12032A151
Person / Time
Site: Susquehanna Talen Energy icon.png
Issue date: 01/16/2012
From: Gerlach R
Susquehanna
To:
Document Control Desk, Office of Nuclear Reactor Regulation
References
0363, 2012-2377
Download: ML12032A151 (24)


Text

Jan.

16, 2012 Page 1

of 2

MANUAL HARD COPY DISTRIBUTION DOCUMENT TRANSMITTAL 2012-2377 USER INFORMATION:

GERLACH*ROSE M EMPL#:028401 CA#:

0363 Address: NUCSA2 Phone#:

254-3194 TRANSMITTAL INFORMATION:

TO:

GERLACH*ROSE M 01/16/2012 LOCATION:

USNRC FROM:

NUCLEAR RECORDS DOCUMENT CONTROL CENTER (NUCSA-2)

THE FOLLOWING CHANGES HAVE OCCURRED TO THE HARDCOPY OR ELECTRONIC MANUAL ASSIGNED TO YOU.

HARDCOPY USERS MUST ENSURE THE DOCUMENTS PROVIDED MATCH THE INFORMATION ON THIS TRANSMITTAL.

WHEN REPLACING THIS MATERIAL IN YOUR HARDCOPY MANUAL, ENSURE THE UPDATE DOCUMENT ID IS THE SAME DOCUMENT ID,OU'RE REMOVING FROM YOUR MANUAL.

TOOLS FROM THE HUMAN PERFORMANCE TOOL BAG SHOULD BE UTILIZED TO ELIMINATE THE CHANCE OF ERRORS.

ATTENTION:

"REPLACE" directions do not affect the Table of Contents, Therefore no TOC will be issued with the updated material.

TSBI -

TECHNICAL SPECIFICATION BASES UNIT 1 MANUAL REMOVE MANUAL TABLE OF CONTENTS DATE: 11/30/2011 ADD MANUAL TABLE OF CONTENTS DATE: 01/13/2012 CATEGORY:

DOCUMENTS TYPE: TSB1 I

Jan. 16, 2012 Page 2

of 2

ID:

TEXT 3.4.3 ADD:

REV:

3 REMOVE:

REV:2 CATEGORY:

ID:

TEXT REMOVE:

DOCUMENTS TYPE:

TSB1 LOES REV:102 ADD:

REV: 103 ANY DISCREPANCIES WITH THE MATERIAL PROVIDED, CONTACT DCS @ X3107 OR X3136 FOR ASSISTANCE.

UPDATES FOR HARDCOPY MANUALS WILL BE DISTRIBUTED WITHIN 3 DAYS IN ACCORDANCE WITH DEPARTMENT PROCEDURES.

PLEASE MAKE ALL CHANGES AND ACKNOWLEDGE COMPLETE IN YOUR NIMS INBOX UPON COMPLETION OF UPDATES.

FOR ELECTRONIC MANUAL

USERS, ELECTRONICALLY REVIEW THE APPROPRIATE DOCUMENTS AND ACKNOWLEDGE COMPLETE IN YOUR NIMS INBOX.

SSES MANUAL Manual Name:

TSB1 Manual

Title:

TECHNICAL SPECIFICATION BASES UNIT 1 MANUAL Table Of Contents Issue Date:

01/13/2012 Procedure Name Rev TEXT LOES 103

Title:

LIST OF EFFECTIVE SECTIONS Issue Date 01/13/2012 Change ID Change Number TEXT TOC

Title:

TABLE OF CONTENTS 20 09/01/2010 TEXT 2.1.1 5

05/06/2009

Title:

SAFETY LIMITS (SLS)

REACTOR CORE SLS TEXT 2.1.2 1

Title:

SAFETY LIMITS (SLS)

REACTOR 10/04/2007 COOLANT SYSTEM (RCS)

PRESSURE S TEXT 3. 0 3

08/,29/2009

Title:

LIMITING CONDITION FOR OPERATION (LCO)

APPLICABILITY TEXT 3.1.1

Title:

REACTIVITY TEXT 3.1.2

Title:

REACTIVITY TEXT 3.1.3

Title:

REACTIVITY TEXT 3.1.4

Title:

REACTIVITY TEXT 3.1.5

Title:

REACTIVITY TEXT 3.1.6

Title:

REACTIVITY 1

04/18/2006 CONTROL SYSTEMS SHUTDOWN MARGIN (SDM) 0 11/15/2002 CONTROL SYSTEMS REACTIVITY ANOMALIES 2

01/19/2009 CONTROL SYSTEMS CONTROL ROD OPERABILITY 4

01/30/2009 CONTROL SYSTEMS CONTROL ROD SCRAM TIMES 1

07/06/2005 CONTROL SYSTEMS CONTROL ROD SCRAM ACCUMULATORS 2

04/18/2006 CONTROL SYSTEMS ROD PATTERN CONTROL Page 1 of 8 Report Date: 01/16/12 Page 1 of 8

Report Date: 01/16/12

SSES MANUAL Manual Name:

TSB1 Manual

Title:

TECHNICAL SPECIFICATION BASES UNIT 1 MANUAL TEXT 3.1.7

Title:

REACTIVITY CONTROL TEXT 3.1.8

Title:

REACTIVITY CONTROL TEXT 3.2.1

Title:

POWER TEXT 3.2.2

Title:

POWER TEXT 3.2.3

Title:

POWER 3

04/23/2008 SYSTEMS STANDBY LIQUID CONTROL (SLC)

SYSTEM 3

05/06/2009 SYSTEMS SCRAM DISCHARGE VOLUME (SDV)

VENT AND DRAIN VALVES 2

04/23/2008 LIMITS AVERAGE PLANAR LINEAR HEAT GENERATION RATE (APLHGR) 3 05/06/2009 LIMITS MINIMUM CRITICAL POWER RATIO (MCPR) 2 04/23/2008 LIMITS LINEAR HEAT GENERATION RATE (LHGR)

DISTRIBUTION DISTRIBUTION DISTRIBUTION TEXT 3.3.1.1

Title:

INSTRUMENTATION TEXT 3.3.1.2

Title:

INSTRUMENTATION TEXT 3.3.2.1

Title:

INSTRUMENTATION TEXT 3.3.2.2

Title:

INSTRUMENTATION TEXT 3.3.3.1

Title:

INSTRUMENTATION TEXT 3.3.3.2

Title:

INSTRUMENTATION TEXT 3.3.4.1

Title:

INSTRUMENTATION 4

04/23/2008 REACTOR PROTECTION SYSTEM (RPS)

INSTRUMENTATION 2

01/19/2009 SOURCE RANGE MONITOR (SRM)

INSTRUMENTATION 3

04/23/2008 CONTROL ROD BLOCK INSTRUMENTATION 2

04/05/2010 FEEDWATER MAIN TURBINE HIGH WATER LEVEL TRIP INSTRUMENTATION 8

10/27/2008 POST ACCIDENT MONITORING (PAM)

INSTRUMENTATION 1

04/18/2005 REMOTE SHUTDOWN SYSTEM 1

04/23/2008 END OF CYCLE RECIRCULATION PUMP TRIP (EOC-RPT)

INSTRUMENTATION1W Page2 of 8

Report Date: 01/16/12 Page 2 of 8

Report Date: 01/16/12

SSES MANUJAL Manual Name:

TSB1 Manual

Title:

TECHNICAL SPECIFICATION BASES UNIT 1 MANUAL TEXT 3.3.4.2 0

11/15/2002

Title:

INSTRUMENTATION ANTICIPATED TRANSIENT WITHOUT SCRAM RECIRCULATION PUMP TRIP (ATWS-RPT)

INSTRUMENTATION TEXT 3.3.5.1 3

08/20/2009

Title:

INSTRUMENTATION EMERGENCY CORE COOLING SYSTEM (ECCS)

INSTRUMENTATION TEXT 3.3.5.2 0

11/15/2002

Title:

INSTRUMENTATION REACTOR CORE ISOLATION COOLING (RCIC)

SYSTEM INSTRUMENTATION TEXT 3.3.6.1 4

04/23/2008

Title:

INSTRUMENTATION PRIMARY CONTAINMENT ISOLATION INSTRUMENTATION TEXT 3.3.6.2 4

09/01/2010

Title:

INSTRUMENTATION SECONDARY CONTAINMENT ISOLATION INSTRUMENTATION TEXT 3.3.7.1

Title:

INSTRUMENTATION INSTRUMENTATION 2

10/27/2008 CONTROL ROOM EMERGENCY OUTSIDE AIR SUPPLY (CREOAS)

SYSTEM TEXT 3.3.8.1 2

12/17/2007

Title:

INSTRUMENTATION LOSS OF POWER (LOP)

INSTRUMENTATION TEXT 3.3.8.2 0

11/15/2002

Title:

INSTRUMENTATION REACTOR PROTECTION SYSTEM (RPS)

ELECTRIC POWER MONITORING TEXT 3.4.1

Title:

REACTOR COOLANT 4

04/27/2010 SYSTEM (RCS)

RECIRCULATION LOOPS OPERATING TEXT 3.4.2 2

04/27/2010

Title:

REACTOR COOLANT SYSTEM (RCS)

JET PUMPS TEXT 3.4.3 3

01/13/2012

Title:

REACTOR COOLANT SYSTEM RCS SAFETY RELIEF VALVES S/RVS TEXT 3.4.4 0

11/15/2002

Title:

REACTOR COOLANT SYSTEM (RCS)

RCS OPERATIONAL LEAKAGE Pages of 8 Report Date: 01/16/12 Page 3 of 8

Report Date: 01/16/12

SSES MANUJAL Manual Name:

TSB1 Manual

Title:

TECHNICAL SPECIFICATION BASES UNIT 1 MANUAL TEXT 3.4.5 1

01/16/2006

Title:

REACTOR COOLANT SYSTEM (RCS)

RCS PRESSURE ISOLATION VALVE (PIV) LEAKAGE TEXT 3.4.6 3

01/25/2011

Title:

REACTOR COOLANT SYSTEM (RCS)

RCS LEAKAGE DETECTION INSTRUMENTATION TEXT 3.4.7 2

10/04/2007

Title:

REACTOR COOLANT SYSTEM (RCS)

RCS SPECIFIC ACTIVITY TEXT 3.4.8

Title:

REACTOR COOLANT HOT SHUTDOWN TEXT 3.4.9

Title:

REACTOR COOLANT COLD SHUTDOWN 1

SYSTEM (RCS) 0 SYSTEM (RCS) 04/18/2005 RESIDUAL HEAT REMOVAL (RHR)

SHUTDOWN COOLING SYSTEM 11/15/2002 RESIDUAL HEAT REMOVAL (RHR)

SHUTDOWN COOLING SYSTEM 04/23/2008 RCS PRESSURE AND TEMPERATURE (P/T) LIMITS TEXT 3.4.10 3

Title:

REACTOR COOLANT SYSTEM (RCS)

TEXT 3.4.11 0

11/15/2002

Title:

REACTOR COOLANT SYSTEM (RCS)

REACTOR STEAM DOME PRESSURE TEXT 3.5.1 2

01/16/2006

Title:

EMERGENCY CORE COOLING SYSTEMS (ECCS)

AND REACTOR SYSTEM ECCS -

OPERATING TEXT 3.5.2 0

11/15/2002

Title:

EMERGENCY CORE COOLING SYSTEMS (ECCS)

AND REACTOR SYSTEM ECCS -

SHUTDOWN TEXT 3.5.3 2

07/09/2010

Title:

EMERGENCY CORE COOLING SYSTEMS (ECCS)

AND REACTOR SYSTEM RCIC SYSTEM CORE ISOLATION COOLING (RCIC)

CORE ISOLATION COOLING (RCIC)

CORE ISOLATION COOLING (RCIC)

TEXT 3.6.1.1

Title:

PRIMARY CONTAINMENT 4

11/09/2011 TEXT 3.6.1.2 1

04/23/2008

Title:

CONTAINMENT SYSTEMS PRIMARY CONTAINMENT AIR LOCK Page4 of 8 Report Date: 01/16/12 Page 4 of.8 Report Date: 01/16/12

SSES MANUAL BASES UNIT 1 MANUAL Manual Name:

TSB1 Manual

Title:

TECHNICAL SPECIFICATION TEXT 3.6.1.3

Title:

CONTAINMENT TEXT 3.6.1.4

Title:

CONTAINMENT TEXT 3.6.1.5

Title:

CONTAINMENT TEXT 3.6.1.6

Title:

CONTAINMENT TEXT 3.6.2.1

Title:

CONTAINMENT TEXT 3.6.2.2

Title:

CONTAINMENT TEXT 3.6.2.3

Title:

CONTAINMENT TEXT 3.6.2.4

Title:

CONTAINMENT TEXT 3.6.3.1

Title:

CONTAINMENT TEXT 3.6.3.2

Title:

CONTAINMENT TEXT 3.6.3.3

Title:

CONTAINMENT TEXT 3.6.4.1

Title:

CONTAINMENT 9

04/14/2010 SYSTEMS PRIMARY CONTAINMENT ISOLATION VALVES (PCIVS)

LDCN 3092 1

04/23/2008 SYSTEMS CONTAINMENT PRESSURE 1

10/05/2005 SYSTEMS DRYWELL AIR TEMPERATURE 0

11/15/2002 SYSTEMS SUPPRESSION CHAMBER-TO-DRYWELL VACUUM BREAKERS 2

04/23/2008 SYSTEMS SUPPRESSION POOL AVERAGE TEMPERATURE 0

11/15/2002 SYSTEMS SUPPRESSION POOL WATER LEVEL 1

01/16/2006 SYSTEMS RESIDUAL HEAT REMOVAL (RHR)

SUPPRESSION POOL COOLING 0

11/15/2002 SYSTEMS RESIDUAL HEAT REMOVAL (RHR)

SUPPRESSION POOL SPRAY 2

06/13/2006 SYSTEMS PRIMARY CONTAINMENT HYDROGEN RECOMBINERS 1

04/18/2005 SYSTEMS DRYWELL AIR FLOW SYSTEM 0

11/15/2002 SYSTEMS PRIMARY CONTAINMENT OXYGEN CONCENTRATION 7

10/04/2007 SYSTEMS SECONDARY CONTAINMENT Page 5 of 8

Report Date: 01/16/12 Page5 of 8 Report Date: 01/16/12

SSES MANUAL Manual Name:

TSB1 Manual

Title:

TECHNICAL SPECIFICATION BASES UNIT 1 MANUAL TEXT 3.6.4.2 3

03/10/2010

Title:

CONTAINMENT SYSTEMS SECONDARY CONTAINMENT ISOLATION VALVES (SCIVS)

TEXT 3.6.4.3 4

09/21/2006

Title:

CONTAINMENT SYSTEMS STANDBY GAS TREATMENT (SGT)

SYSTEM TEXT 3.7.1

Title:

PLANT SYSTEMS ULTIMATE HEAT TEXT 3.7.2

Title:

PLANT SYSTEMS TEXT 3.7.3

Title:

PLANT SYSTEMS TEXT 3.7.4

Title:

PLANT SYSTEMS TEXT 3.7.5

Title:

PLANT SYSTEMS TEXT 3.7.6

Title:

PLANT SYSTEMS TEXT 3.7.7

Title:

PLANT SYSTEMS TEXT 3.7.8

Title:

PLANT SYSTEMS 4

04/05/2010 RESIDUAL HEAT REMOVAL SERVICE WATER (RHRSW)

SYSTEM AND THE SINK (UHS) 2 02/11/2009 EMERGENCY SERVICE WATER (ESW)

SYSTEM 1

01/08/2010 CONTROL ROOM EMERGENCY OUTSIDE AIR SUPPLY (CREOAS)

SYSTEM 0

11/15/2002 CONTROL ROOM FLOOR COOLING SYSTEM 1

10/04/2007 MAIN CONDENSER OFFGAS 2

04/23/2008 MAIN TURBINE BYPASS SYSTEM 1

10/04/2007 SPENT FUEL STORAGE POOL WATER LEVEL 0

04/23/2008 TEXT 3. 8.1 6

05/06/2009

Title:

ELECTRICAL POWER SYSTEMS AC SOURCES -

OPERATING TEXT 3.8.2 0

11/15/2002

Title:

ELECTRICAL POWER SYSTEMS AC SOURCES -

SHUTDOWN Page6 of 8

Report Date: 01/16/12 Page 6 of 8

Report Date: 01/16/12

SSES MANUAL Manual Name:

TSBI Manual

Title:

TECHNICAL SPECIFICATION BASES UNIT 1 MANUAL TEXT 3.8.3

Title:

ELECTRICAL TEXT 3.8.4

Title:

ELECTRICAL TEXT 3.8.5

Title:

ELECTRICAL TEXT 3.8.6

Title:

ELECTRICAL TEXT 3.8.7

Title:

ELECTRICAL TEXT 3.8.8

Title:

ELECTRICAL TEXT 3.9.1

Title:

REFUELING TEXT 3.9.2

Title:

REFUELING TEXT 3.9.3

Title:

REFUELING TEXT 3.9.4

Title:

REFUELING TEXT 3.9.5

Title:

REFUELING TEXT 3.9.6

Title:

REFUELING 2

04/14/2010 POWER SYSTEMS DIESEL FUEL OIL, LUBE OIL, AND STARTING AIR 3

01/19/2009 POWER SYSTEMS DC SOURCES -

OPERATING 1

12/14/2006 POWER SYSTEMS DC SOURCES -

SHUTDOWN POWER SYST POWER SYST POWER SYST OPERATIONS OPERATIONS OPERATIONS OPERATIONS OPERATIONS OPERATIONS 1

12/14/2006

'EMS BATTERY CELL PARAMETERS 1

10/05/2005

'EMS DISTRIBUTION SYSTEMS OPERATING 0

11/15/2002

'EMS DISTRIBUTION SYSTEMS -

SHUTDOWN 0

11/15/2002 REFUELING EQUIPMENT INTERLOCKS 1

09/01/2010 REFUEL POSITION ONE-ROD-OUT INTERLOCK 0

11/15/2002 CONTROL ROD POSITION 0

11/15/2002 CONTROL ROD POSITION INDICATION 0

11/15/2002 CONTROL ROD OPERABILITY -

REFUELING 1

10/04/2007 REACTOR PRESSURE VESSEL (RPV) WATER LEVEL Page 7 of 8 Report Date: 01/16/12 Page7 of 8

Report Date: 01/16/12

SSES MANUJAL Manual Name:

TSB1,W Manual

Title:

TECHNICAL SPECIFICATION BASES UNIT 1 MANUAL TEXT 3.9.7 0

11/15/2002

Title:

REFUELING OPERATIONS RESIDUAL HEAT REMOVAL (RHR)

HIGH WATER LEVEL TEXT 3.9.8 0

11/15/2002

Title:

REFUELING OPERATIONS RESIDUAL HEAT REMOVAL (RHR)

LOW WATER LEVEL TEXT 3.10.1

Title:

SPECIAL TEXT 3.10.2

Title:

SPECIAL TEXT 3.10.3

Title:

SPECIAL TEXT 3.10.4

Title:

SPECIAL TEXT 3.10.5

Title:

SPECIAL TEXT 3.10.6

Title:

SPECIAL TEXT 3.10.7

Title:

SPECIAL TEXT 3.10.8

Title:

SPECIAL OPERATIONS OPERATIONS OPERATIONS OPERATIONS OPERATIONS OPERATIONS OPERATIONS OPERATIONS 1

01/23/2008 INSERVICE LEAK AND HYDROSTATIC TESTING OPERATION 0

11/15/2002 REACTOR MODE SWITCH INTERLOCK TESTING 0

11/15/2002 SINGLE CONTROL ROD WITHDRAWAL HOT SHUTDOWN 0

11/15/2002 SINGLE CONTROL ROD WITHDRAWAL

-COLD SHUTDOWN 0

11/15/2002 SINGLE CONTROL ROD DRIVE (CRD)

REMOVAL REFUELING 0

11/15/2002 MULTIPLE CONTROL ROD WITHDRAWAL,--

REFUELING 1

04/18/2006 CONTROL ROD TESTING OPERATING' 1

04/12/2006 SHUTDOWN MARGIN (SDM)

TEST -

REFUELING Pae f8RprtDt:0/61 Page 8 of 8

Report Date: 01/16/12

SUSQUEHANNA STEAM ELECTRIC STATION LIST OF EFFECTIVE SECTIONS (TECHNICAL SPECIFICATIONS BASES)

Section Title Revision TOC Table of Contents 20 B 2.0 SAFETY LIMITS BASES Page B 2.0-1 0

Page TS / B 2.0-2 3

Page TS / B 2.0-3 5

Page TS / B 2.0-4 3

Page TS / B 2.0-5 5

Page TS / B 2.0-6 1

Pages TS / B 2.0-7 through TS / B 2.0-9 1

B 3.0 LCO AND SR APPLICABILITY BASES Page TS / B 3.0-1 1

Pages TS / B 3.0-2 through TS / B 3.0-4 0

Pages TS / B 3.0-5 through TS / B 3.0-7 1

Page TS / B 3.0-8 3

Pages TS / B 3.0-9 through TS / B 3.0-11 2

Page TS / B 3.0-1 la 0

Page TS / B 3.0-12 1

Pages TS / B 3.0-13 through TS / B 3.0-15 2

Pages TS / B 3.0-16 and TS / B 3.0-17 0

B 3.1 REACTIVITY CONTROL BASES Pages B 3.1-1 through B 3.1-4

,0 Page TS / B 3.1-5 1

Pages TS / B 3.1-6 and TS / B 3.1-7 2

Pages B 3.1-8 through B 3.1-13 0

Page TS / B 3.1-14 1

Page B 3.1-15 0

Page TS / B 3.1-16 1

Pages B 3.1-17 through B 3.1-19 0

Pages TS / B 3.1-20 and TS / B 3.1-21 1

Page TS / B 3.1-22 0

Page TS / B 3.1-23 1

Page TS / B 3.1-24 0

Pages TS / B 3.1-25 through TS / B 3.1-27 1

Page TS / B 3.1-28 2

Page TS / B 3.1-29 1

Pages B 3.1-30 through B 3.1-33 0

Pages TS / B 3.3-34 through TS / B 3.3-36 1

Pages TS / B 3.1-37 and TS / B 3.1-38 2

Pages TS / B 3.1-39 and TS / B 3.1-40 2

Page TS I B 3.1-40a 0

Pages TS / B 3.1-41 and TS / B 3.1-42 2

SUSQUEHANNA - UNIT 1 TS / B LOES-1 Revision 103

SUSQUEHANNA STEAM ELECTRIC STATION LISTOFEFFECTIVE SECTIONS (TECHNICAL SPECIFICATIONS BASES)

Section Title Revision Page TS / B 3.1.43 1

Page TS / B 3.1-44 0

Page TS / B 3.1-45 3

Pages TS / B 3.1-46 through TS I B 3.1-49 1

Page TS / B 3.1-50 0

Page TS / B 3.1-51 3

B 3.2 POWER DISTRIBUTION LIMITS BASES Page TS / B 3.2-1 2

Pages TS / B 3.2-2 and TS / B 3.2-3 3

Pages TS / B 3.2-4 and TS / B 3.2-5 2

Page TS / B 3.2-6 3

Page B 3.2-7 1

Pages TS / B 3.2-8 and TS / B 3.2-9 3

Page TS / B 3.2.10 2

Page TS / B 3.2-11 3

Page TS / B 3.2-12 1

Page TS / B 3.2-13 2

B 3.3 INSTRUMENTATION Pages TS / B 3.3-1 through TS I B 3.3-4 1

Page TSI B 3.3-5 2

Page TS / B 3.3-6 1

Page TS / B 3.3-7 3

Page TS / B 3.3-7a 1

Page TS / B 3.3-8 4

Pages TS / B 3.3-9 through TS / B 3.3-12 3

Pages TS / B 3.3-12a 1

Pages TS / B 3.3-12b and TS / B 3.3-12c 0

Page TS / B 3.3-13 1

Page TS / B 3.3-14 3

Pages TS / B 3.3-15 and TS / B 3.3-16 1

Pages TS / B 3.3-17 and TS / B 3.3-18 4

Page TS / B 3.3-19 1

Pages TS / B 3.3-20 through TS / B 3.3-22 2

Page TS / B 3.3-22a 0

Pages.TS / B 3.3-23 and TS / B 3.3-24 2

Pages TS / B 3.3-24a and TS / B 3.3-24b 0

Page TS / B 3.3-25 3

Page TS / B 3.3-26 2

Page TS / B 3.3-27 1

Pages TS / B 3.3-28 through TS / B 3.3-30 3

Page TS / B 3.3-30a 0

SUSQUEHANNA-UNITi TS/BLOES-2 Revision 103 SUSQUEHANNA - UNIT 1 TS / B LOES-2 Revision 103

SUSQUEHANNA STEAM ELECTRIC STATION LIST OF EFFECTIVE SECTIONS (TECHNICAL SPECIFICATIONS BASES)

Section Title Revision Page TS / B 3.3-31 4

Page TS / B 3.3-32 5

Pages TS / B 3.3-32a 0

Page TS / B 3.3-32b 1

Page TS / B 3.3-33 5

Page TS / B 3.3-33a 0

Page TS / B 3.3-34 1

Pages TS / B 3.3-35 and TS / B 3.3-36 2

Pages TS / B 3.3-37 and TS / B 3.3-38 1

Page TS / B 3.3-39 2

Pages TS / B 3.3-40 through TS / B 3.3-43 1

Page TS / B 3.3-44 4

Pages TS / B 3.3-44a and TS / B 3.3-44b 0

Page TS / B 3.3-45 3

Pages TS / B 3.3-45a and TS / B 3.3-45b 0

Page TS / B 3.3-46 3

Pages TS / B 3.3-47 2

Pages TS / B 3.3-48 through TS / B 3.3-51 3

Pages TS / B 3.3-52 and TS / B 3.3-53 2

Page TS / B 3-3-53a 0

Page TS / B 3.3-54 4

Page TS / B 3.3-55 2

Pages TS / B 3.3-56 and TS / B 3.3-57 1

Page TS / B 3.3-58 0

Page TS I B 3.3-59 1

Page TS / B 3.3-60 0

Page TS / B 3.3-61 1

Pages TS / B 3.3-62 and TS / B 3.3-63 0

Pages TS / B 3.3-64 and TS / B 3.3-65 2

Page TS / B 3.3-66 4

Page TS / B 3.3-67 3

Page TS / B 3.3-68 4

Page TS / B 3.3-69 5

Pages TS / B 3.3-70 4

Page TS / B 3.3-71 3

Pages TS / B 3.3-72 and TS / B 3.3-73 2

Page TS / B 3.3-74 3

Page TS / B 3.3-75 2

Page TS / B 3.3-75a 6

Page TS / B 3.3-75b 7

Page TS / B 3.3-75c 5

SUSQUEHANNA

- UNIT 1 TS/BLOES-3 Revision 103 SUSQUEHANNA - UNIT 1 TS / B LOES-3 Revision 103

SUSQUEHANNA STEAM ELECTRIC STATION LIST OF EFFECTIVE SECTIONS (TECHNICAL SPECIFICATIONS BASES)

Section Title Revision Pages B 3.3-76 through 3.3-77 0

Page TS / B 3.3-78 1

Pages B 3.3-79 through B 3.3-81 0

Page B 3.3-82 1

Page B 3.3-83 0

Pages B 3.3-84 and B 3.3-85 1

Page B 3.3-86 0

Page B 3.3-87 1

Page B 3.3-88 0

Page B 3.3-89 1

Page TS / B 3.3-90 1

Page B 3.3-91 0

Pages TS / B 3.3-92 through TS 1 B 3.3-100 1

Pages TS / B 3.3-101 through TS I B 3.3-103 0

Page TS / B 3.3-104 2

Pages TS / B 3.3-105 and TS/ B 3.3-106 0

Page TS / B 3.3-107 1

Page TS / B 3.3-108 0

Page TS / B 3.3-109 1

Pages TS I B 3.3-110 and TSI/B 3.3-111 0

Pages TS / B 3.3-112 and TS / B 3.3-112a 1

Pages TS / B 3.3-113 through TS/ B 3.3-115 1

Page TS / B 3.3-116 3

Page TS / B 3.3-117 1

Pages TS I B 3.3-118 through TS / B 3.3-122 0

Pages TS./ B 3.3-123 and TS / B 3.3-124 1

Page TS / B 3.3-124a 0

Page TS / B 3.3-125 0

Pages TS / B 3.3-126 and TS / B 3.3-127 1

Pages TS / B 3.3-128 through TS/ B 3.3-130 0

Page TS / B 3.3-131 1

Pages TS / B 3.3-132 through TS / B 3.3-134 0

Pages B 3.3-135 through B 3.3-137 0

Page TS / B 3.3-138 1

Pages B 3.3-139 through B 3.3-149 0

Pages TS / B 3.3-150 and TS/ B 3.3-151 1

Pages TS / B 3.3-152 through TS / B 3.3-154 2

Page TS / B 3.3-155 1

Pages TS / B 3.3-156 through TS / B 3.3-158 2

Pages TS / B 3.3-159 through TS / B 3.3-162 1

Page TS / B 3.3-163 2

Pages TS / B 3.3-164 and TS / B 3.3-165 1

Pages TS I B 3.3-166 and TS / B 3.3-167 2

SUSQUEHANNA-UNITi TSIBLOES-4 Revision 103 SUSQUEHANNA - UNIT 1 TS / B LOES-4 Revision 103

SUSQUEHANNA STEAM ELECTRIC STATION LIST OFEFFECTIVE SECTIONS (TECHNICAL SPECIFICATIONS BASES)

Section Title Revision Pages TS / B 3.3-168 and TS / B 3.3-169 1

Page TS / B 3.3-170 2

Pages TS / B 3.3-171 through TS / B 3.3-177 1

Pages TS / B 3.3-178 through TS / B 3.3-179a 2

Pages TS / B 3.3-179b and TS / B 3.3-179c 0

Page TS / B 3.3-180 1

Page TS / B 3.3-181 3

Page TS / B 3.3-182 1

Page TS / B 3.3-183 2

Page TS / B 3.3-184 1

Page TS / B 3.3-185 4

Page TS/ B 3.3-186 1

Pages TS / B 3.3-187 and TS / B 3.3-188 2

Pages TS / B 3.3-189 through TS I B 3.3-191 1

Page TS / B 3.3-192 0

Page TS / B 3.3-193 1

Pages TS / B 3.3-194 and TS / B 3.3-195 0

Page TS / B 3.3-196 2

Pages TS / B 3.3-197 through TS / B 3.3-204 0

Page TS / B 3.3-205 1

Pages B 3.3-206 through B 3.3-209 0

Page TS / B 3.3-210 1

Pages B 3.3-211 through B 3.3-219 0

B 3.4 REACTOR COOLANT SYSTEM BASES Pages B 3.4-1 and B 3.4-2 0

Pages TS / B 3.4-3 and Page TS / B 3.4-4 4

Page TS / B 3.4-5 3

Pages TS / B 3.4-6 through TS / B 3.4-9 2

Page TS / B 3.4-10 1

Pages TS / 3.4-11 and TS / B 3.4-12 0

Page TS / B 3.4-13 1

Page TS / B 3.4-14 0

Page TS / B 3.4-15 2

Pages TS / B 3.4-16 and TS / B 3.4-17 4

Page TS / B 3.4-18 2

Pages B 3.4-19 through B 3.4-27 0

Pages TS / B 3.4-28 through TS / B 3.4-30 1

Page TS / B 3.4-31 0

Pages TS / B 3.4-32 and TS / B 3.4-33 1

Page TS / B 3.4-34 0

Pages TS / B 3.4-35 and TS/ B 3.4-36 1

Page TS / B 3.4-37 2

Page TS / B 3.4-38 1

SUSQUEHANNA - UNIT 1 SUSQUEHANNA -

UNIT 1 TS/BLOES-5 Revision 103 TS / B LOES-5 Revision 103

SUSQUEHANNA STEAM ELECTRIC STATION LIST OF EFFECTIVE SECTIONS (TECHNICAL SPECIFICATIONS BASES)

Section Title Revision Pages B 3.4-39 and B 3.4-40 0

Page TS / B 3.4-41 1

Pages B 3.4-42 through B 3.4-48 0

Page TS / B 3.4-49 3

Page TS / B 3.4-50 1

Page TS / B 3.4-51 3

Page TS /'B 3.4-52 2

Page TS / B 3.4-53 1

Pages TS / B 3.4-54 through TS / B 3.4-56 2

Page TS / B 3.4-57 3

Pages TS / B 3.4-58 through TS / B 3.4-60 1

B 3.5 ECCS AND RCIC BASES Pages B 3.5-1 and B 3.5-2 0

Page TS / B 3.5-3 2

Page TS / B 3.5-4 1

Page TS / B 3.5-5 2

Page TS / B 3.5-6 1

Pages B 3.5-7 through B 3.5-10 0

Page TS / B 3.5-11 1

Page TS / B 3.5-12 0

Page TS / B 3.5-13 1

Pages TS / B 3.5-14 and TS / B 3.5-15 0

Pages TS / B 3.5-16 through TS / B 3.5-18 1

Pages B 3.5-19 through B 3.5-24 0

Page TS / B 3.5-25 through TS / B 3.5-27 1

Page TS / B 3.5-28 0

Page TS / B 3.5-29 1

Pages TS / B 3.5-30 and TS / B 3.5-31 0

B 3.6 CONTAINMENT SYSTEMS BASES Page TS / B 3.6-1 2

Page TS / B 3.6-1a 3

Page TS / B 3.6-2 4

Page TS / B 3.6-3 3

Page TS / B 3.6-4 4

Pages TS / B 3.6-5 and TS B B 3.6-6 3

Page TS / B 3.6-6a 2

Page TS / B 3.6-6b 3

Page TS / B 3.6-6c 0

Page B 3.6-7 0

Page B 3.6-8 1

Pages B 3.6-9 through B 3.6-14 0

Page TS / B 3.6-15 2

Page TS / B 3.6-15a 0

Page TS / B 3.6-15b 2

SUSQUEHANNA - UNIT 1 TS / B LOES-6 Revision 103

SUSQUEHANNA STEAM ELECTRIC STATION LIST OF EFFECTIVE SECTIONS (TECHNICAL SPECIFICATIONS BASES)

Section Title Revision Pages TS / B 3.6-16 and TS / B 3.6-17 1

Page TS / B 3.6-17a 0

Pages TS / B 3.6-18 and TS I B 3.6-19 0

Page TS / B 3.6-20 1

Page TS / B 3.6-21 2

Page TS / B 3.6-22 1

Page TS / B 3.6-22a 0

Page TS / B 3.6-23 1

Pages TS / B 3.6-24 and TS / B 3.6-25 0

Pages TS / B 3.6-26 and TS / B 3.6-27 2

Page TS / B 3.6-28 7

Page TS / B 3.6-29 2

Page TS / B 3.6-30 1

Page TS / B 3.6-31 3

Pages TS / B 3.6-32 and TS / B 3.6-33 1

Pages TS / B 3.6-34 and TS / B 3.6-35 0

Page TS / B 3.6-36 1

Page TS / B 3.6-37 0

Page TS / B 3.6-38 3

Page TS / B 3.6-39 2

Page TS / B 3.6-40 6

Page B 3.6-41 1

Pages B 3.6-42 and B 3.6-43 3

Pages TS / B 3.6-44 and TS / B 3.6-45 1

Page TS / B 3.6-46 2

Pages TS / B 3.6-47 through TS / B 3.6-51 1

Page TS / B 3.6-52 2

Pages TS / B 3.6-53 through TS / B 3.6-56 0

Page TS / B 3.6-57 1

Page TS / 3.6-58 2

Pages B 3.6-59 through B 3.6-63 0

Pages TS / B 3.6-64 and TS / B 3.6-65 1

Pages B 3.6-66 through B 3.6-69 0

Pages TS / B 3.6-70 through TS / B 3.6-72 1

Page TS / B 3.6-73 2

Pages TS / B 3.6-74 and TS / B 3.6-75 1

Pages B 3.6-76 and B 3.6-77 0

Page TS / B 3.6-78 1

Pages B 3.6-79 through B 3.3.6-83 0

Page TS / B 3.6-84 3

Page TS / B 3.6-85 2

Page TS / B 3.6-86 4

SUSQUEHANNA - UNIT 1 TS I B LOES-7 Revision 103 SUSQUEHANNA - UNIT 1.

TS / B LOES-7 Revision 103

SUSQUEHANNA STEAM ELECTRIC STATION LIST OF EFFECTIVE SECTIONS (TECHNICAL SPECIFICATIONS BASES)

Section Title Revision Pages TS / B 3.6-87 through TS / B 3.6-88a 2

Page TS / B 3.6-89 4

Page TS / B 3.6-90 2

Page TS / B 3.6-91 3

Pages TS / B 3.6-92 through TS / B 3.6-96 1

Page TS / B 3.6-97 2

Pages TS / B 3.6-98 and TS / B 3.6-99 1

Page TS / B 3.6-100 3

Page TS / B 3.6-100a 0

Pages TS / B 3.6-101 and TS / B 3.6-102 1

Pages TS / B 3.6-103 and TS I B 3.6-104 2

Page TS / B 3.6-105 3

Page TS / B 3.6-106 2

Page TS / B 3.6-107 3

B 3.7 PLANT SYSTEMS BASES Pages TS / B 3.7-1 3

Page TS / B 3.7-2 4

Pages TS / B 3.7-3 through TS / B 3.7-5 3

Page TS / B 3.7-5a 1

Page TS / B 3.7-6 3

Page TS / B 3.7-6a 2

Page TS / B 3.7-6b 1

Page TS / B 3.7-6c 2

Page TS / B 3.7-7 3

Page TS / B 3.7-8 2

Pages TS / B 3.7-9 through TS I B 3.7-11 1

Pages TS / B 3.7-12 and TS / B 3.7-13 2

Pages TS / B 3.7-14 through TS / B 3.7-18 3

Page TS / B 3.7-18a 1

Pages TS / B 3.7-18b through TS / B 3.7-18e 0

Pages TS / B 3.7-19 through TS / B 3.7-23 1

Page TS / B 3.7-24 1

Pages TS / B 3.7-25 and TS / B 3.7-26 0

Pages TS / B 3.7-27 through TS / B 3.7-29 5

Page TS / B 3.7-30 2

Page TS / B 3.7-31 1

Page TS / B 3.7-32 0

Page TS / B 3.7-33 1

Pages TS / B 3.7-34 through TS / B 3.7-37 0

SUSQUEHANNA

- UNIT I TS / B LOES-8 Revision 103 SUSQUEHANNA - UNIT 1 TS / B LOES-8 Revision 103

SUSQUEHANNA STEAM ELECTRIC STATION LIST OF EFFECTIVE SECTIONS (TECHNICAL SPECIFICATIONS BASES)

Section Title Revision B 3.8 ELECTRICAL POWER SYSTEMS BASES Page TS / B 3.8-1 3

Pages TS / B 3.8-2 and TS / B 3.8-3 2

Page TS / B 3.8-4 3

Pages TS / B 3.8-4a and TS / B 3.8-4b 0

Page TS / B 3.8-5 5

Page TS / B 3.8-6 3

Pages TS / B 3.8-7 through TS/B 3.8-8 2

Page TS / B 3.8-9 4

Page TS I B 3.8-10 3

Pages TS / B 3.8-11 and TS / B 3.8-17 2

Page TS / B 3.8-18 3

Pages TS / B 3.8-19 through TS / B 3.8-21 2

Pages TS / B 3.8-22 and TS / B 3.8-23 3

Pages TS / B 3.8-24 through TS / B 3.8-37 2

Pages B 3.8-38 through B 3.8-44 0

Page TS / B 3.8-45 1

Pages TS / B 3.8-46 through TS / B 3.8-48 0

Pages TS / B 3.8-49 through TS / B 3.8-51 1

Page TS / B 3.8-52 0

Page TS / B 3.8-53 1

Pages TS / B 3.8-54 through TS / B 3.8-57 2

Pages TS / B 3.8-58 through TS / B 3.8-61 3

Pages TS / B 3.8-62 and TS / B 3.8-63 5

Page TS / B 3.8-64 4

Page TS / B 3.8-65 5

Pages TS / B 3.8-66 through TS / B 3.8-77 1

Pages TS / B 3.8-77A through TS / B 3.8-77C 0

Pages B 3.8-78 through B 3.8-80 0

Page TS / B 3.8-81 1

Pages B 3.8-82 through B 3.8-90 0

B 3.9 REFUELING OPERATIONS BASES Pages TS / B 3.9-1 and TS / B 3.9-1a 1

Pages TS / B 3.9-2 through TS / B 3.9-5 1

Pages TS / B 3.9-6 through TS / B 3.9-8 0

Pages B 3.9-9 through B 3.9-18 0

Pages TS / B 3.9-19 through TS / B 3.9-21 1

Pages B 3.9-22 through B 3.9-30 0

SUSQUEHANNA-UNITI TS / B LOES-9 Revision 103 SUSQUEHANNA - UNIT 1 TS / B LOES-9 Revision 103

SUSQUEHANNA STEAM ELECTRIC STATION LIST OF EFFECTIVE SECTIONS (TECHNICAL SPECIFICATIONS BASES)

Section Title Revision B 3.10 SPECIAL OPERATIONS BASES Page TS / B 3.10-1 2

Pages TS / B 3.10-2 through TS I B 3.10-5 1

Pages B 3.10-6 through B 3.10-31 0

Page TS / B 3.10-32 2

Page B 3.10-33 0

Page TS / B 3.10-34 1

Pages B 3.10-35 and B 3.10-36 0

Page TS / B 3.10-37 1

Page TS / B 3.10-38 2

TSB1 Text LOES.doc 1/10/2012 SUSQUEHANNA - UNIT I TS I B LOES-lO Revision 103 SUSQUEHANNA - UNIT 1 TS / B LOES-10 Revision 103

PPL Rev. 3 S/RVs B 3.4.3 B 3.4 REACTOR COOLANT SYSTEM (RCS)

B 3.4.3 Safety/Relief Valves (S/RVs)

BASES BACKGROUND The ASME Boiler and Pressure Vessel Code requires the reactor pressure vessel be protected from overpressure during upset conditions by self-actuated safety valves. As part of the nuclear pressure relief system, the size and number of S/RVs are selected such that peak pressure in the nuclear system will not exceed the ASME Code limits for the reactor coolant pressure boundary (RCPB).

The S/RVs are located on the main steam lines between the reactor vessel and the first isolation valve within the drywell. There are a total of 16 S/RVs of which any 14 are required to be OPERABLE. The S/RVs can actuate by either of two modes: the safety mode or the relief mode. In the safety mode (or spring mode of operation), the valve opens when steam pressure at the valve inlet overcomes the spring force holding the valve closed. This satisfies the Code requirement.

Each S/RV discharges steam through a discharge line to a point below the minimum water level in the suppression pool. Six S/RVs also serve as the Automatic Depressurization System (ADS) valves. The ADS requirements are specified in LCO 3.5.1, "ECCS-Operating."

APPLICABLE SAFETY ANALYSES The overpressure protection system must accommodate the most severe pressurization transient. Evaluations have determined that the most severe transient is the closure of all main steam isolation valves (MSIVs),

followed by reactor scram on high neutron flux (i.e., failure of the direct scram associated with MSIV position) (Ref. 1). For the purpose of the analyses, 14 of the 16 S/RVs are assumed to operate in the safety mode.

The analysis results demonstrate that the design S/RV capacity is capable of maintaining reactor pressure below the ASME Code limit of 110% of vessel design pressure (110% x 1250 psig = 1375 psig). This LCO helps to ensure that the acceptance limit of 1375 psig is met during the Design Basis Event.

(continued)

SUSQUEHANNA - UNIT 1 TS / B 3.4-15 Revision 2

PPL Rev. 3 S/RVs B 3.4.3 BASES APPLICABLE From an overpressure standpoint, the design basis events are bounded SAFETY by the MSIV closure with flux scram event described above. Reference 2 ANALYSES discusses additional events that are expected to actuate the S/RVs.

(continued)

S/RVs satisfy Criterion 3 of the NRC Policy Statement (Ref. 4).

LCO The safety function of 14 of the 16 S/RVs are required to be OPERABLE to satisfy the assumptions of the safety analysis (Refs. 1 and 2). The requirements of this LCO are applicable only to the capability of the S/RVs to mechanically open to relieve excess pressure when the lift setpoint is exceeded (safety function).

The S/RV setpoints are established to ensure that the ASME Code limit on peak reactor pressure is satisfied. The ASME Code specifications require the lowest safety valve setpoint to be at or below vessel design pressure (1250 psig) and the highest safety valve to be set so that the total accumulated pressure does not exceed 110% of the design pressure for overpressurization conditions. The transient evaluations in the FSAR are based on these setpoints, but also include the additional uncertainty of + 3%, - 5% of the nominal setpoint to provide an added degree of conservatism.

Operation with fewer valves OPERABLE than specified, or with setpoints outside the ASME limits, could result in a more severe reactor response to a transient than predicted, possibly resulting in the ASME Code limit on reactor pressure being exceeded.

APPLICABILITY In MODES 1, 2, and 3, all required SIRVs must be OPERABLE, since considerable energy may be in the reactor core and the limiting design basis transients are assumed to occur in these MODES. The S/RVs may be required to provide pressure relief to discharge energy from the core until such time that the Residual Heat Removal (RHR) System is capable of dissipating the core heat.

In MODE 4 reactor pressure is low enough that the overpressure limit is unlikely to be approached by assumed (continued)

SUSQUEHANNA - UNIT 1 TS / B 3.4-16 Revision 4

PPL Rev. 3 S/RVs B 3.4.3 BASES APPLICABILITY operational transients or accidents. In MODE 5, the reactor vessel head is (continued) unbolted or removed and the reactor is at atmospheric pressure. The S/RV function is not needed during these conditions.

ACTIONS A.1 and A.2 With less than the minimum number of required S/RVs OPERABLE, a transient may result in the violation of the ASME Code limit on reactor pressure. If the safety function of one or more required S/RVs is inoperable, the plant must be brought to a MODE in which the LCO does not apply. To achieve this status, the plant must be brought to MODE 3 within 12 hours1.388889e-4 days <br />0.00333 hours <br />1.984127e-5 weeks <br />4.566e-6 months <br /> and to MODE 4 within 36 hours4.166667e-4 days <br />0.01 hours <br />5.952381e-5 weeks <br />1.3698e-5 months <br />. The allowed Completion Times are reasonable, based on operating experience, to reach required plant conditions from full power conditions in an orderly manner and without challenging plant systems.

SURVEILLANCE SR 3.4.3.1 REQUIREMENT The Surveillance requires that the required S/RVs will open at the pressures assumed in the safety analysis of Reference 1. The demonstration of the S/RV safe lift settings must be performed during shutdown, since this is a bench test, to be done in accordance with the Inservice Testing Program. The lift setting pressure shall correspond to ambient conditions of the valves at nominal operating temperatures and pressures. The S/RV setpoint is.+ 3%, - 5% of the nominal setpoint for OPERABILITY. Requirements for accelerated testing are established in accordance with the Inservice Test Program. Any of the 16 S/RVs, identified in this Surveillance Requirement, with their associated setpoints, can be designated as the 14 required S/RVs. This maintains the assumptions in the overpressure analysis.

A Note is provided to allow up to two of the required 14 S/RVs to be physically replaced with S/RVs with lower setpoints until the next refueling outage. This provides operational flexibility which maintains the assumptions in the over-pressure analysis.

(continued)

SUSQUEHANNA - UNIT 1 TS / B 3.4-17 Revision 4

PPL Rev. 3 S/RVs B 3.4.3 BASES SURVEILLANCE REQUIREMENTS SR 3.4.3.1 (continued)

The Frequency of this Surveillance is established in accordance with the Inservice Testing Program.

REFERENCES

1. FSAR, Section 5.2.2.1.4.
2. FSAR, Section 15.
3. ASME Operation and Maintenance Code.
4. Final Policy Statement on Technical Specifications Improvements, July 22, 1993 (58 FR 39132).

SUSQUEHANNA - UNIT 1 TS / B 3.4-18 Revision 2