September 26, 2011 Dr. Paul J. OConnor Facility Director Dow Chemical TRIGA Research Reactor Dow Chemical Company Building 1602 Midland, MI 48674

SUBJECT:

DOW CHEMICAL COMPANY - REVIEW OF THE REVISED EMERGENCY PLAN SUBMITTED JULY 7, 2011, (TAC NO. ME1595)

Dear Dr. OConnor:

As part of your application for renewal of Facility Operating License No. R-108 for the Dow Chemical Company TRIGA Reactor (DTRR), dated April 1, 2009, as supplemented, you submitted your Emergency Plan (EP) for review. On October 11, 2010, you responded to our request for additional information (RAI) regarding the EP, dated September 16, 2010. By letter dated May 24, 2011 and supplemented by letter dated July 7, 2011 you submitted a revised EP that addressed all the RAIs.

We have reviewed the DTRR EP dated July 7, 2011 against the guidance listed below and have determined that the DTRR EP dated July 7, 2011 continues to meet the requirements of Title 10 of the Code of Federal Regulations (10 CFR), Appendix E.

Regulation 10 CFR 50.34(b)(6)(v)

Regulatory Guide 2.6, Emergency Planning for Research and Test Reactors ANSI-15.16-2008, Emergency Planning for Research Reactors NUREG-0849, Standard Review Plan for the Review and Evaluation of Emergency Plans for Research and Test Reactors NRC Information Notice 97-34, Deficiencies in Licensee Submittals Regarding Terminology for Radiological Emergency Action Levels in Accordance with the New Part 20 NRC Information Notice 92-79, Nonpower Reactor Emergency Response

We request that you commence implementing this approved EP revision immediately. If you have any questions, please contact me at 301-415-0893 or by electronic mail at:

Geoffrey.wertz@nrc.gov.

Sincerely,

/RA by L. Tran for/

Geoffrey Wertz, Project Manager Research and Test Reactor Licensing Branch Division of Policy and Rulemaking Office of Nuclear Reactor Regulation Docket No. 50-264 cc: See next page

Dow Chemical Company Docket No. 50-264 cc:

Office of the Mayor 333 West Ellsworth Midland, MI 48640 Office of the Governor Room 1 - Capitol Building Lansing, MI 48913 Mr. Dan Rader Environmental Health and Safety Responsible Care Leader Chair, Radiation Safety Committee 1790 Building Midland, MI 48674 Dr. Wayde Konze Global Research and Development Director for Analytical Sciences Chair, Reactor Operations Committee The Dow Chemical Company 1897 Building Midland, MI 48667 Test, Research, and Training Reactor Newsletter University of Florida 202 Nuclear Sciences Center Gainesville, FL 32611

We request that you commence implementing this approved EP revision immediately. If you have any questions, please contact me at 301-415-0893 or by electronic mail at:

Geoffrey.wertz@nrc.gov.

Sincerely,

/RA by L. Tran for/

Geoffrey Wertz, Project Manager Research and Test Reactor Licensing Branch Division of Policy and Rulemaking Office of Nuclear Reactor Regulation Docket No. 50-264 cc: See next page DISTRIBUTION:

PUBLIC DPR/PRT r/f RidsNrrDpr RidsNrrDprPrta RidsNrrDprPrtb GWertz, NRR GLappert, NRR JAnderson, NRR ACCESSION NO.: ML112590262

  • concurrence via e-mail, **Input provided by ML112030350 NRR-106 Office PRLB:PM*

PRLB:LA NSIR/DPR/ORLOB*

PRLB:ABC PRLB:PM*

Name GWertz GLappert JAnderson PSilva GWertz, LNT for Date 9/22/2011 9/22/11 7/28/2011 9/22/2011 9/22/2011 OFFICIAL RECORD COPY