Inservice Testing Program Description: Safety-Related Seismic Restraints (Snubbers) for the Third 10-Year Interval
ML110810657
Person / Time
Site: South Texas  
(NPF-076, NPF-080)
Issue date: 03/14/2011
From: Ruvalcaba M
South Texas
To:
Document Control Desk, Office of Nuclear Reactor Regulation
References
NOC-AE-11002651
Download: ML110810657 (59)


Text

Nuclear Operating Company South Texas Pro/ect Electric GeneratmIn Station PO Box 289 Wadsworth. Texas 77483 March 14, 2011 NOC-AE-1 1002651 File No.: G25 10 CFR 50.55a U. S. Nuclear Regulatory Commission Attention: Document Control Desk One White Flint North 11555 Rockville Pike Rockville, MD 20852 South Texas Project Units 1 & 2 Docket Nos. STN 50-498, STN 50-499 Inservice Testing Program

Description:

Safety-Related Seismic Restraints (Snubbers) for the Third 10-Year Interval

Reference:

Marco Ruvalcaba, STP Nuclear Operating Company, to NRC Document Control Desk, "Inservice Testing Program

Description:

Safety-Related Seismic Restraints (Snubbers) for the Third 10-Year Interval,"

dated July 13, 2010 (NOC-AE-10002565) (ML102010290)

Pursuant to 10 CFR 50.55a(g), STP Nuclear Operating Company (STPNOC) updated the South Texas Project Inservice Testing (IST) snubber program for the third 10-year interval applicable to safety-related seismic restraints (snubbers) as noted in the referenced correspondence. The IST snubber program plan describes the programmatic aspects for snubber inservice testing implemented with the third 10-year interval beginning September 25, 2010. STPNOC submits the attached program description in accordance with section ISTA-3200 of the ASME OM Code, 2004 Edition, no addenda.

The IST snubber program plan is written in accordance with the requirements of the ASME OM Code, 2004 Edition, No Addenda, Subsections ISTA and ISTD with the inspection requirements of Code Case OMN-13, Revision 0.

The IST snubber program plan complies with the applicable limitations and modifications as stated in 10 CFR 50.55a(b) related to implementation of the 2004 ASME OM Code. Therefore, NRC approval is not required prior to implementation.

There are no commitments included with this submittal.

If there are any questions, please contact either Mr. P. L. Walker at (361) 972-8392 or me at (361) 972-7904.

/Marco Ruivalcab

Manager, Testing and Programs Engineering PILW

Attachment:

Unit 1 and 2 Snubber Inservice Test Plan STI: 32837946

NOC-AE-1 1002651 Page 2 of 2 cc:

(paper copy)

(electronic copy)

  • transmittal letter only Regional Administrator, Region IV U. S. Nuclear Regulatory Commission 612 East Lamar Blvd., Suite 400 Arlington, Texas 76011-8064 Balwant K. Singal Senior Project Manager U.S. Nuclear Regulatory Commission One White Flint North (MS 8B1) 11555 Rockville Pike Rockville, MD 20852 Senior Resident Inspector U. S. Nuclear Regulatory Commission P. O. Box 289, Mail Code: MN116 Wadsworth, TX 77483
  • C. M. Canady City of Austin Electric Utility Department 721 Barton Springs Road Austin, TX 78704
  • transmittal letter only
  • John Ragan
  • Catherine Callaway
  • Balwant K. Singal U. S. Nuclear Regulatory Commission
  • Richard Pena
  • E. Alarcon
  • Kevin Polio City Public Service
  • C. Mele City of Austin
  • Peter Nemeth Crain Caton & James, P.C.

SOUTH TEXAS PROJECT ELECTRIC GENERATING STATION INSERVICE TESTING PROGRAM UNIT 1 AND 2 SNUBBER INSERVICE TEST PLAN THIRD TEN-YEAR INTERVAL SOUTH TEXAS PROJECT UNITS I AND 2 DOCKET NOS. STN 50-498, STN 50-499 FACILITY OPERATING LICENSE NOS. NPF-76/80 COMMERCIAL OPERATING DATES Unit 1: 8/25/1988 Unit 2: 6/19/1989 THIRD TEN-YEAR INTERVAL DATES 9/25/2010 THROUGH 9/24/2020 Approved by:

Approved by:

Approved by:

C_

/-,

S. Shojaei "

IST Snuibber Program Engineer

/.Younge SuM rvuvlc abasting/Programs Engineering

/

PMruvgaslcaba

/

Testing/Programs Engineering Manager c-Date Date zD-Z

- 7at e

Date Revision 0

SOUTH TEXAS PROJECT ELECTRIC GENERATING STATION Unit I and 2 Snubber Inservice Test Plan REVISION 0

SUMMARY

SHEET SECTION EFFECTIVE CHANGE PAGE(S)

Revision 0 Revision 0 i

SOUTH TEXAS PROJECT ELECTRIC GENERATING STATION Unit 1 and 2 Snubber Inservice Test Plan TABLE OF CONTENTS SECTION DESCRIPTION PAGE

1.0 INTRODUCTION

1 1.1 Overview 1

1.2 Program Test Plan 1

2.0 SCOPE 2

2.1 Overview 2

2.2 Code Classification 2

2.3 Snubber IST Listing 3

2.4 Implementing Processes [Acceptance Criteria /

3 Test or Examination Methods / Frequency or Schedule 2.5 Applicable Documents [P&IDs / Procedures]

4 3.0 METHOD OF EVALUATING SNUBBERS 13 4.0 ALTERNATIVE REQUIREMENTS TO OM CODE 14 4.1 Code Cases 14 4.2 10CFR50.55a Requirements - Code Cases 14 4.3 Code Case Adoption 15 4.4 Relief Requests 17 4.5 50.55a Limitations, Modifications and 18 Clarifications Revision 0 ii

SOUTH TEXAS PROJECT ELECTRIC GENERATING STATION Unit 1 and 2 Snubber Inservice Test Plan TABLE OF CONTENTS SECTION DESCRIPTION PAGE 5.0 INTERPRETATIONS TO THE OM CODE 19 6.0 PROGRAM IMPLEMENTATION 19 7.0 PROGRAM CONFIGURATION CONTROL 20 8.0 TEST PLAN ATTACHMENTS 20 Unit 1 Snubber IST Listing Unit 2 Snubber IST Listing Snubber Code Cases - Information Only Snubber Interpretation - Information Only Revision 0 iii

SOUTH TEXAS PROJECT ELECTRIC GENERATING STATION Unit 1 and 2 Snubber Inservice Test Plan

1.0 INTRODUCTION

1.1 Overview 10CFR50.55a and the South Texas Project (STP) Technical Requirements Manual invoke inservice testing (IST) of Snubbers per ASME OM Code (Code of Operation and Maintenance of Nuclear Power Plants). Part 50.55a establishes the requirements that each nuclear power plant must develop and implement an inservice inspection and testing program. Inservice tests are used to verify operational readiness of Snubbers whose function is required for safety. The tests conducted during successive 120-month intervals must comply with the requirements of the latest edition and addenda of the OM Code that is in effect 12 months prior to the start of the interval.

Title 10, Part 50.55a of the Code of Federal Regulations invoke, by reference, the requirement for inservice inspection (ISI) of Snubbers per Section XI of the ASME Boiler and Pressure Vessel Code.

STP begins its third IST 10-year interval of commercial plant operation for Unit I & 2 on September 25, 2010 and ends on September 24, 2020.

The Snubber Inservice Test Plan was developed in accordance with the requirements of I OCFR50.55a that became effective on October 15, 2008.

The edition and addenda of the ASME OM Code for the Snubber IST Program for the third 10-year interval is the 2004 Edition No Addenda, Subsections ISTA & ISTD [the Code].

1.2 Program Test Plan Since the period of time that the requirement for inservice testing was first incorporated into the Code of Federal Regulations; the NRC, ASME, and the nuclear industry have provided additional interpretations to the Code requirements. These interpretations have been documented through various mechanisms such as 1 OCFR50.55a Final Rules, Code Cases, Code Interpretations, generic letters, program review meetings, site inspections, and others. It is the intent of the Program Plan to:

0 Establish a set criteria and philosophy for determining the Snubber Testing Scope, Evaluate each plant Snubber in a consistent manner to identify which Snubbers SHOULD be included in the testing program and to identify the extent, Identify Alternative requirements to the Code, Identify implementation processes of testing required for each snubber, and implementing documents.

Revision 0 Page 1 of 20

SOUTH TEXAS PROJECT ELECTRIC GENERATING STATION Unit 1 and 2 Snubber Inservice Test Plan 2.0 SCOPE 2.1 Overview The scope of the Snubber IST Program includes those Snubbers that are required to perform a specific function in shutting down the reactor to a safe shutdown condition, in maintaining the safe shutdown condition, or in mitigating the consequences of an accident.

This program was developed to encompass system safety requirements defined in 10 CFR 50 as well as Snubber functions required in response to the abnormal operational transients and accidents defined in the UFSAR. The program is not limited to the postulated accidents of UFSAR Chapter 15. The UFSAR, Technical Specifications, and related design basis documents are the primary references used to determine which Snubbers are required to perform specific functions related to the spectrum of postulated accidents.

The only snubbers excluded from this program are those installed on nonsafety-related systems, and then only if their failure or failure of the system on which they are installed would have no adverse effect on any safety-related system.

2.2 Code Classification The quality group classification system for water, steam, and radioactive waste containing components important to the safety of water-cooled nuclear power plants is established by NRC Regulatory Guide 1.26, in conjunction with 1 OCFR50.55a. Regulatory Guide 1.26, "Quality Group Classification and Standards", defines the Quality Group Classification System consisting of four Quality Groups, A through D. Quality Group A is defined as "Reactor Coolant Pressure Boundary" (Class 1) by I 0CFR50.2. The definitions of Groups B, C, and D (Class 2, Class 3 and non-classed, respectively) are provided by Regulatory Guide 1.26.

Revision 0 Page 2 of 20

SOUTH TEXAS PROJECT ELECTRIC GENERATING STATION Unit 1 and 2 Snubber Inservice Test Plan 2.3 Snubber IST Listing The Snubber IST Listing was previously known as the Snubber Index prior to invoking ASME OM Code. The Snubber IST Listing is maintained as the Snubber Database, which is an electronic database containing component test and inspection history, acceptance criteria, and references.

The Snubber Database is used to identify snubbers to be tested in accordance with the requirements of the Code. The Snubber Database contains, as a minimum, the following information about each Snubber:

Snubber identification (Snubber number, model number, and serial number)

Applicable plant system ASME Code class (same as Quality Group Classifications in R.G. 1.26)

Snubber location information Test or examination method Test and examination history Reference Attachment 1 (Unit I Snubber IST Listing) & Attachment 2 (Unit 2 Snubber IST Listing) for a listing of snubbers tested and examined in accordance with this plan.

The listing provides basic information about the scoped snubbers.

2.4 Implementing Processes Program inservice tests required by the Code SHALL be implemented using the Surveillance Test Program process. The Surveillance Test Program provides acceptance criteria for the tests and examinations. As a result of the performed tests, any identified corrective actions and subsequent retests SHALL be made per the requirements of the Code and the ASME Section XI Repair/Replacement Program.

In conjunction with the Surveillance Test Program process, other STP site documents detail Code requirements and implementation processes [test or examination methods and frequency or schedule].

The Condition Reporting (CR) process at STP provides a method to document material deficiencies and engineering evaluations required to comply with the Code. Work orders initiated by the CR process will be used to implement corrective maintenance on snubbers identified for Inservice Testing and will allow for recording and tracking component history.

Revision 0 Page 3 of 20

SOUTH TEXAS PROJECT ELECTRIC GENERATING STATION Unit 1 and 2 Snubber Inservice Test Plan 2.5 Applicable Documents The details of the Snubber IST Program referenced in this Test Plan are contained in documents that are available at STP. These documents include, but are not limited to, piping and instrumentation diagrams, piping isometric drawings, component support drawings, and procedures that support implementation of the Snubber IST program.

2.5.1 Piping and Instrumentation Diagrams (P&IDS)

This section provides a listing of the various piping and instrumentation diagrams applicable to the Snubber IST Program. Table 1 provides a listing of the piping systems containing Class 1, 2, or 3 snubbers, and applicable Instrumentation Diagrams (P&ID's) for these Class 1, 2, and 3 piping systems. Table 1 is arranged in alphabetical system abbreviation.

Revision 0 Page 4 of 20

SOUTH TEXAS PROJECT ELECTRIC GENERATING STATION Unit 1 and 2 Snubber Inservice Test Plan Table 1 Piping and Instrumentation Diagrams System System Drawing Sheet Abbr.

Designation Number No.

Drawing Title AF Auxiliary Feedwater 5S141F00024 1

Auxiliary Feedwater 5S141F00024 2

Auxiliary Feedwater 5S142F00024 1

Auxiliary Feedwater 5S142F00024 2

Auxiliary Feedwater 5S199F00020#1 Condensate Storage System (Note 1) 5S199F00020#2 Condensate Storage System (Note 1)

AP Post Accident Sampling 5Z549Z47501#1 Post Accident Sampling System 5Z549Z47501#2 Post Accident Sampling System 5Z I69Z00046# 1 Containment Hydrogen Monitoring System (Note 2) 5Z 169Z00046#2 Containment Hydrogen Monitoring System (Note 2)

BA Breathing Air 5Q129F05044#1 Low Pressure Breathing Air System (Note 3) 5Q129F05044#2 Low Pressure Breathing Air System (Note 3)

CC Component Cooling 5R209F05017#1 Component Cooling Water System 5R209F05017#2 Component Cooling Water System 5R209F05018#1 Component Cooling Water System 5R209F05018#2 Component Cooling Water System 5R209F05019#1 Component Cooling Water System 5R209F05019#2 Component Cooling Water System 5R209F05020#1 Component Cooling Water System Revision 0 Page 5 of 20

SOUTH TEXAS PROJECT ELECTRIC GENERATING STATION Unit I and 2 Snubber Inservice Test Plan Table 1 (Cont'd.)

Piping and Instrumentation Diagrams System System Drawing Sheet Abbr.

Designation Number No.

Drawing Title 5R209F05020#2 Component Cooling Water System 5R209F05021#1 Component Cooling Water System 5R209F05021#2 Component Cooling Water System CH Essential Chilled Water 5V119V10001#1 Essential Chilled Water System 5V 119V10001#2 Essential Chilled Water System 3V 119V10002#1 Essential Chilled Water System 3VI 19V10002#2 Essential Chilled Water System 3V 119V10003#1 Essential Chilled Water System 3VI 19V10003#2 Essential Chilled Water System 3V 119V 10004# 1 Essential Chilled Water System 3VI 19V 10004#2 Essential Chilled Water System CM Containment Hydrogen 5Z 169Z00046#1 Containment Hydrogen Monitoring System Monitoring 5Z 169Z00046#2 Containment Hydrogen Monitoring System CS Containment Spray 5N109F05037#1 Containment Spray System 5N109F05037#2 Containment Spray System 5N129F05013#1 Safety Injection System (Note 4) 5N129F05013#2 Safety Injection System (Note 4) 5N129F05014#1 Safety Injection System (Note 4)

Revision 0 Page 6 of 20

SOUTH TEXAS PROJECT ELECTRIC GENERATING STATION Unit 1 and 2 Snubber Inservice Test Plan Table 1 (Cont'd.)

Piping and Instrumentation Diagrams System System Drawing Sheet Abbr.

Designation Number No.

Drawing Title 5N 129F05014#2 Safety Injection System (Note 4) 5N129F05015#1 Safety Injection System (Note 4) 5N 129F05015#2 Safety Injection System (Note 4)

CV Chemical and Volume 5R179F05005#1 Chemical & Volume Control System Control 5R179F05005#2 Chemical & Volume Control System 5R179F05006#1 Chemical & Volume Control System 5R179F05006#2 Chemical & Volume Control System 5R179F05007#1 Chemical & Volume Control System 5R179F05007#2 Chemical & Volume Control System 5R179F05008#1 Chem & Vol Control Sys BTRS Sub Sys 5R179F05008#2 Chem & Vol Control Sys BTRS Sub Sys 5RI79F05009#1 Chemical & Volume Control System 5RI79F05009#2 Chemical & Volume Control System DI Standby Diesel Generator 5Q 159F22543# 1 Diesel Air Intake & Exhaust Systems Combustion Air Intake 5Q 159F22543#2 Diesel Air Intake & Exhaust Systems DO Standby Diesel Generator 5Q159F00045#1 1

Sdby Gen Fuel Oil Stor & Trans System Fuel Oil

_5Q159F00045#1 2

Sdby Gen Fuel Oil Stor & Trans System Revision 0 Page 7 of 20

SOUTH TEXAS PROJECT ELECTRIC GENERATING STATION Unit 1 and 2 Snubber Inservice Test Plan Table 1 (Cont'd.)

Piping and Instrumentation Diagrams System System Drawing Sheet Abbr.

Designation Number No.

Drawing Title 5Q159F00045#2 1

Sdby Gen Fuel Oil Stor & Trans System 5Q159F00045#2 2

Sdby Gen Fuel Oil Stor & Trans System DW Demineralized Water 5S199F05034#1 Demin Water Dist Sys RCB FHB & MEAB (Note 3) 5S199F05034#2 Demin Water Dist Sys RCB FHB & MEAB (Note 3)

DX Standby Diesel Generator 5Q159F22543#1 Diesel Air Intake & Exhaust Systems Combustion Gas Exhaust 5Q 159F22543#2 Diesel Air Intake & Exhaust Systems ED Radioactive Vents and 5Q069F05030#1 Radioactive Vents And Drains System (Note 3)

Drains 5Q069F05030#2 Radioactive Vents And Drains System (Note 3)

EW Essential Cooling Water 5Q159F22541#1 Standby Diesel Gen Sys Cooling Water (Note 5) 5Q159F22541#2 Standby Diesel Gen Sys Cooling Water (Note 5) 5R289F05038#1 1

Essential Cooling Water System - TRN 1A 5R289F05038#1 2

Essential Cooling Water System - TRN lB 5R289F05038#1 3

Essential Cooling Water System - TRN 1C 5R289F05038#2 1

Essential Cooling Water System - TRN 2A 5R289F05038#2 2

Essential Cooling Water System - TRN 2B 5R289F05038#2 3

Essential Cooling Water System - TRN 2C 5R289F05039#1 Essential Cooling Water System Revision 0 Page 8 of 20

SOUTH TEXAS PROJECT ELECTRIC GENERATING STATION Unit 1 and 2 Snubber Inservice Test Plan Table 1 (Cont'd.)

Piping and Instrumentation Diagrams System System Drawing Sheet Abbr.

Designation Number No.

Drawing Title 5R289F05039#2 Essential Cooling Water System FC Spent Fuel Pool Cooling 5R219F05028#1 Spent Fuel Pool Cooling & Cleanup Sys 5R219F05028#2 Spent Fuel Pool Cooling & Cleanup Sys 5R219F05029#1 Spent Fuel Pool Cooling & Cleanup Sys 5R219F05029#2 Spent Fuel Pool Cooling & Cleanup Sys FP Fire Protection 5Q279F05047#1 FH,IVC, Contmnt Bldg Fire Protection Sys (Note 3) 5Q279F05047#2 FH,IVC, Contmnt Bldg Fire Protection Sys (Note 3)

FW Feedwater 5S139F00062#1 Feedwater System 5S 139F00062#2 Feedwater System 5S139F00063# 1 Feedwater System 5S139F00063#2 Feedwater System HC Containment Building 5V149V00018#1 Containment Bldg. HVAC System Normal Purge (Note 3)

HVAC 5V 149V00018#2 Containment Bldg. HVAC System Normal Purge (Note 3) 5V149V00019#1 Containment Bldg. HVAC System Supplementary Purge (Note 3) 5V149V00019#2 Containment Bldg. HVAC System Supplementary Purge (Note 3)

IA Instrument Air 5Q119F05040#1 Fuel Hndlng Bldg & RCB Inst Air System (Note 3) 5Q119F05040#2 Fuel Hndlng Bldg & RCB Inst Air System (Note 3)

IL Integrated Leak Test 5C560F05058 Containment Leak Rate Test Pressurization System (Note 3)

Revision 0 Page 9 of 20

SOUTH TEXAS PROJECT ELECTRIC GENERATING STATION Unit 1 and 2 Snubber Inservice Test Plan Table 1 (Cont'd.)

Piping and Instrumentation Diagrams System System Drawing Sheet Abbr.

Designation Number No.

Drawing Title JW Standby Diesel Generator 5Q159F22540#1 Standby Diesel Generator Sys Jacket Water Jacket Water 5Q159F22540#2 Standby Diesel Generator Sys Jacket Water LU Standby Diesel Generator 5Q159F22542#1 Standby Diesel Generator Sys Lube Oil Lube Oil 5Q159F22542#2 Standby Diesel Generator Sys Lube Oil MS Main Steam 5S109F00016#1 Main Steam System 5S109F00016#2 Main Steam System 5S141F00024 1

Auxiliary Feedwater (Note 6) 5S141F00024 2

Auxiliary Feedwater (Note 6) 5S142F00024 1

Auxiliary Feedwater (Note 6) 5S142F00024 2

Auxiliary Feedwater (Note 6)

PO Reactor Coolant Pump Oil 5R379F05042#1 Reactor C/P Oil Changing System (Note 3)

Change-Out 5R379F05042#2 Reactor C/P Oil Changing System (Note 3)

PS Primary Sampling 5Z329Z00045#1 Primary Sampling System 5Z329Z00045#2 Primary Sampling System RA Radiation Monitoring 5V149V00017#1 HVAC React. Cntmnt Bldg. Sys. Composite (Note 7) 5V149V00017#2 HVAC React. Cntmnt Bldg. Sys. Composite (Note 7)

RC Reactor Coolant 5R149F05001#1 RCS Primary Coolant Loop Revision 0 Page 10 of 20

SOUTH TEXAS PROJECT ELECTRIC GENERATING STATION Unit 1 and 2 Snubber Inservice Test Plan Table 1 (Cont'd.)

Piping and Instrumentation Diagrams System System Drawing Sheet Abbr.

Designation Number No.

Drawing Title 5R149F05001#2 RCS Primary Coolant Loop 5R149F05003#1 RCS Pressurizer 5R149F05003#2 RCS Pressurizer 5R I49F05004# 1 RCS Pressurizer Relief Tank 5R149F05004#2 RCS Pressurizer Relief Tank RD Reactor Coolant System 5R349F05046#1 RCS Vacuum Degassing System (Note 3)

Degassing 5R349F05046#2 RCS Vacuum Degassing System (Note 3)

RH Residual Heat Removal 5R169F20000#1 Residual Heat Removal System 5R169F20000#2 Residual Heat Removal System RM Reactor Makeup Water 5R279F05033#1 Reactor Makeup Water System 5R279F05033#2 Reactor Makeup Water System SA Station Air 5Q109F05041#1 FHB & RCB Service Air System (Note 3) 5Q109F05041#2 FHB & RCB Service Air System (Note 3)

SB Steam Generator Blowdown 5S209F20001#1 Steam Generator Blowdown System 5S209F20001#2 Steam Generator Blowdown System SD Standby Diesel Generator 5Q159F22546#1 Standby Diesel Starting Air System Starting Air 5Q 159F22546#2 Standby Diesel Starting Air System SI Safety Injection 5N129F05013#1 Safety Injection System Revision 0 Page 11 of 20

SOUTH TEXAS PROJECT ELECTRIC GENERATING STATION Unit 1 and 2 Snubber Inservice Test Plan Table 1 (Cont'd.)

Piping and Instrumentation Diagrams System System Drawing Sheet Abbr.

Designation Number No.

Drawing Title 5N129F05013#2 Safety Injection System 5N129F05014#1 Safety Injection System 5N 129F05014#2 Safety Injection System 5N129F05015#1 Safety Injection System 5N 129F05015#2 Safety Injection System 5N129F05016#1 Safety Injection System 5N129F05016#2 Safety Injection System SL Steam Generator Sludge 5S209F05057#1 Stm Gen Sludge Lancing & Chem Cleaning Sys Lancing (Note 3) 5S209F05057#2 Stm Gen Sludge Lancing & Chem Cleaning Sys (Note 3)

WL Liquid Waste Processing 5R309F05022#1 Liquid Waste Processing System (Note 3) 5R309F05022#2 Liquid Waste Processing System (Note 3)

Notes:

1.

2.

3.

4.

5.

6.

7.

Includes AF piping.

Includes AP piping.

Class 2 containment penetration piping and isolation valves only.

Includes CS piping.

Includes EW piping.

Includes MS piping.

Includes RA piping; Class 2 containment penetration piping and isolation valves only.

Revision 0 Page 12 of 20

SOUTH TEXAS PROJECT ELECTRIC GENERATING STATION Unit 1 and 2 Snubber Inservice Test Plan 2.5.2 Procedures Table 2 lists applicable Snubber IST Program procedures.

Table 2 Snubber Program Procedures PROCEDURE PROCEDURE TITLE NUMBER OPGP03-ZE-0009 Snubber Testing Program OPSP11-SN-0001 Mechanical Snubber Visual Examination (surveillance procedure)

OPSP1 1-SN-0002 Hydraulic Snubber Visual Inspection (surveillance procedure)

OPSP 11 -SN-0003 Mechanical Snubbers Functional Test (surveillance procedure)

OPSP 11-SN-0004 Hydraulic Snubber Functional Test (surveillance procedure)

OPSP1 1-SN-0005 Snubber Service Life Review and Reevaluation (surveillance procedure) 3.0 METHOD OF EVALUATING SNUBBERS The Master Equipment Database and system design basis documents were reviewed to determine which systems include snubbers that encompass system safety requirements defined in 10 CFR 50 as well as snubbers required in response to the abnormal operational transients and accidents defined in the UFSAR. This review was not limited to the postulated accidents of UFSAR Chapter 15.

Each system was reviewed in the following manner:

The P&ID for each system was reviewed to identify the system boundaries for each class of snubbers that are subject to a specific function in shutting down a reactor to the safe shutdown condition, maintaining the safe shutdown condition, or in mitigating the consequences of an accident.

Each snubber was reviewed for design and installation arrangement for allowances for adequate access and clearances for conduct of tests.

The Snubber IST Listing was developed from the above review activities.

Revision 0 Page 13 of 20

SOUTH TEXAS PROJECT ELECTRIC GENERATING STATION Unit 1 and 2 Snubber Inservice Test Plan 4.0 ALTERNATIVE REQUIREMENTS TO OM CODE This section lists the alternative requirements to the Code for specific portions of the Snubber IST Program. The alternative requirements identified meet the rules for alternative requirements that are.defined in the Code.

4.1 Code Cases Code Cases to be used during a preservice or inservice test examinations SHALL be identified in the Test Plan [ISTA 3130(a)].

Code Cases SHALL be applicable to the edition and addenda specified in the Test Plan [ISTA 3130(b)].

Code Cases SHALL be in effect at the time the test plan is filed [ISTA 3130(c)].

Code Cases issued subsequent to filing the Test Plan MAY be proposed for use in amendments to the Test Plan [ISTA 3130(d)].

Superseded Code Cases approved for use MAY continue to be used [ISTA 3140].

Code Cases approved for use MAY be used after annulment for the duration of the Test Plan [ISTA 3150].

Endorsement of Regulatory Guide 1.192 "Operation and Maintenance Code Case Acceptability, ASME OM Code", does NOT commit the STP to all code cases listed therein, but rather allows for selection of applicable code cases. The purpose of this endorsement is to identify all code cases that could potentially be incorporated into this IST Program Plan.

4.2 1 OCFR50.55a Requirements - Code Cases 1 OCFR50.55a(b)(6) addresses the application of Code Cases and states the following criteria:

Licensees MAY apply the ASME Operation and Maintenance Nuclear Power Plants Code cases listed in Regulatory Guide 1.192 without prior NRC approval subject to the following:

When a licensee initially applies a listed Code case, the licensee SHALL apply the most recent version of that Code case.

Revision 0 Page 14 of 20

SOUTH TEXAS PROJECT ELECTRIC GENERATING STATION Unit 1 and 2 Snubber Inservice Test Plan If a licensee has previously applied a Code case and a later version of the Code case is incorporated, the licensee MAY continue to apply, to the end of the current 120-month interval, the previous version of the Code case as authorized or MAY apply the later version of the Code case, including any NRC-specified conditions placed on its use Application of an annulled Code case is prohibited unless a licensee previously applied the listed Code case prior to it being listed as annulled in Regulatory Guide 1.192. If a licensee has applied a listed Code case that is later listed as annulled in Regulatory Guide 1.192, the licensee MAY continue to apply the Code case to the end of the current 120-month interval.

4.3 Code Case Adoption:

4.3.1 Adoption of Code Cases Accepted for Generic Use in Regulatory Guide 1.192 Code cases that are designated "Acceptable" or "Conditionally Acceptable" for generic use in Regulatory Guide 1.192 (latest revision) have been adopted for use by listing them in Table 3. All conditions or limitations delineated in Regulatory Guide 1.192 for applicable code cases will apply.

4.3.2 Adoption of Code Cases Not Accepted for Generic Use in Regulatory Guide 1.192 via Submittal of Relief Requests Adoption of code cases that have been approved by the ASME Board of Nuclear Codes and Standards, but that have NOT been accepted for generic use in Regulatory Guide 1.192, MAY be submitted in the form of a relief request in accordance with 10CFR50.55a(a)(3). Once approved, these relief requests will be available for use by STP. The Relief Request is approved for use until the end of the 10-year interval in which it was approved.

Table 4 lists those code cases for which relief requests have been submitted. In addition to the requirements stated in the code cases, criteria MAY be stipulated in the relief request OR MAY be agreed upon through subsequent correspondence with the NRC. STP will implement these additional requirements as applicable.

Revision 0 Page 15 of 20

SOUTH TEXAS PROJECT ELECTRIC GENERATING STATION Unit 1 and 2 Snubber Inservice Test Plan Table 3 Adopted Code Cases Approved in Regulatory Guide 1.192 Code Affected Case Code Case Title Program Number Area OMIN-13 Requirements for Extending Snubber Inservice Visual Snubber visual exams Examination Interval at LWR Power Plants Table 4 Code Cases Submitted Through Relief Requests Code (1) Relief Request No.

Affected Case Code Case Title (2) Correspondence No.

Program Number (3) Relief Request Date Area NONE (1)

(2) 1(3)

Revision 0 Page 16 of 20

SOUTH TEXAS PROJECT ELECTRIC GENERATING STATION Unit 1 and 2 Snubber Inservice Test Plan 4.4 Relief Requests Relief from the requirements of the OM Code SHALL be requested where full compliance with the Code will not be achieved. Relief requests are submitted to the NRC for approval pursuant to the requirements of 10 CFR 50.5 5a.

Table 5 provides a listing of additional relief requests, not associated with a code case, that have been written in accordance with I OCFR50.55a(a)(3) when specific inservice testing requirements are considered impractical. If other examination requirements are determined to be impractical during the course of the interval, relief requests SHALL be submitted in accordance with 10CFR50.55a.

Table 5 Relief Requests Not Associated With a Code Case (1) Relief Request No.

Affected Relief Request Subject (2) Correspondence No.

Program (3) Relief Request Date Area NONE (1)

(2)

(3)

Revision 0 Page 17 of 20

SOUTH TEXAS PROJECT ELECTRIC GENERATING STATION Unit 1 and 2 Snubber Inservice Test Plan 4.5 50.55a Limitations, Modifications and Clarifications Certain paragraphs in 10CFR50.55a list the limitations, modifications, and/or clarifications to the implementation requirements of the Code. The paragraphs in 10CFR50.55a applicable to STP are listed in Table 6.

TABLE 6 CODE OF FEDERAL REGULATIONS 10CFR50.55a LIMITATIONS 10CFR50.55a Paragraphs Limitations, Modifications, and Clarifications 10CFR50.55a(b)(3)(v)

Subsection ISTD. Article IWF-5000, "Inservice Inspection Requirements for Snubbers," of the ASME BPV Code,Section XI, provides inservice inspection requirements for examinations and tests of snubbers at nuclear power plants. Licensees MAY use Subsection ISTD, "Inservice Testing of Dynamic Restraints (Snubbers) in Light-Water Reactor Power Plants," ASME OM Code, 1995 Edition through the latest edition and addenda incorporated by reference in paragraph (b)(3) of this section, in place of the requirements for snubbers in Section XI, IWF-5200(a) and (b) and IWF-5300(a) and (b), by making appropriate changes to their technical specifications or licensee-controlled documents. Preservice and inservice examinations must be performed using the VT-3 visual examination method described I in IWA-2213.

Revision 0 Page 18 of 20

SOUTH TEXAS PROJECT ELECTRIC GENERATING STATION Unit 1 and 2 Snubber Inservice Test Plan 5.0 INTERPRETATIONS TO THE OM CODE This section lists interpretations to the Code for specific portions of the Snubber IST Program.

Code interpretations provide clarification to the intent of Code requirements. Although the NRC agrees with most interpretations, some are inconsistent with NRC requirements. NRC requirements SHALL be met. Interpretations serve to support the users understanding of Code requirements. Many interpretations address specific circumstances. Therefore, the context of the interpretation must be thoroughly understood prior to its application at STP.

Code interpretations applicable to Snubber IST Program are listed in Table 7.

TABLE 7 OM CODE INTERPRETATIONS Interpretation Interpretation Description / Subject Application No.

Impact 04-10 ASME Code-1998 through OMb-2000 Snubber testin 6.0 PROGRAM IMPLEMENTATION The Snubber Testing Program procedure (OPGP03-ZE-0009) details program implementation based on the Code and alternate requirements of the Code.

Snubber program inservice tests required by the Code SHALL be implemented using the Surveillance Test Program. The snubber surveillance test program SHALL be used to identify the test method for verifying operational readiness of the snubber, to identify the frequency of the required tests, to establish plant conditions for performing tests, and to document the results of snubber testing. The surveillance tests act as the record of testing required by the Code.

Reference Table 2 for a listing of the applicable snubber ITS program implementing procedures.

Revision 0 Page 19 of 20

SOUTH TEXAS PROJECT ELECTRIC GENERATING STATION Unit 1 and 2 Snubber Inservice Test Plan 7.0 PROGRAM CONFIGURATION CONTROL As a minimum the program will be reviewed and revised as necessary for compliance with the Code in effect as referenced by 10CFR50.55a 12 months prior to the end of the third 120-month interval of commercial operation. Additionally, the scope of the program is subject to revision due to changes in system design, changes in design that affect the snubber safety function, or revisions to the applicable code requirements through Alternate Requirements to the Code. In order to accommodate these changes STP reserves the right to submit program revisions that will enhance or improve the program at any time within the effective interval.

8.0 TEST PLAN ATTACHMENTS, Unit 1 Snubber IST Listing, Unit 2 Snubber IST Listing, Code Cases - Information Only, Interpretations - Information Only Revision 0 Page 20 of 20

ATTACHMENT 1 Unit 1 Snubber IST Listing Revision 0

Unit-1 Snubber IST Listing Pages 1 of 13 Mdtpns Tagtpns /

Snubber 2C11 1XSNO001A 2C11 lXSNO001B 2C111XSN0001C 2C11 1XSNO001D 2C11 1XSNO002A 2C11 1XSN0002B 2C111XSNO002C 2C11 XSNO002D 2C11 XSN0003A 2C11 1XSN0003B 2C11 1XSNO003C 2C11 XSNO003D 2C11 1XSNO004A 2C11 lXSNO004B 2C11 1XSNO004C 2C11 lXSN0004D AF1006HL5003 AF1006HL5015 AF1006HL5018 AF1006HL5035N AF1006HL5035S AF1008HL5028 AF1008HL5029 AF1008HL5030 AF1008HL5041 N AF1008HL5041 S AF1010HL5002L AF1010 HL5002U AF1010HL5007E AF101OHL5007W Model No HYD-1300KIP HYD-1300KIP HYD-1300KIP HYD-1300KIP HYD-1300KIP HYD-1300KIP HYD-1300KIP HYD-1300KIP HYD-1300KIP HYD-1300KIP HYD-1300KIP HYD-1300KIP HYD-1300KIP HYD-1300KIP HYD-1300KIP HYD-1300KIP AD5501 AD5501 AD5501 AD5501 AD5501 AD5501 AD5501 AD5501 AD5501 AD5501 AD5501 AD5501 AD5501 AD5501 Qc Level 2

2 2

2 2

2 2

2 2

2 2

2 2

2 2

2 2

2 2

2 2

2 2

2 2

2 2

2 2

2 Route / Location RCB SGA-NE RCB SGB-N/E RCB SGC-N/E RCB SGD-N/E RCB SGA-N/W RCB SGB-N/W RCB SGC-N/W RCB SGD-N/W RCB SGA-S/W RCB SGB-S/W RCB SGC-S/W RCB SGD-S/W RCB SGA-S/E RCB SGB-S/E RCB SGC-S/E RCB SGD-S/E RCB SGAD>52' RCB SGAD>52' RCB OMB >19' RCB SGAD>68' RCB SGAD>68' RCB SGAD>68' RCB SGAD>68' RCB OMB >19' RCB SGAD>68' RCB SGAD>68' RCB OMB >19' RCB OMB >19' RCB SGBC>52' RCB SGBC>52' Elev 58 58 58 58 58 58 58 58 58 58 58 58 58 58 58 58 19 19 19 19 19 19 19 19 19 19 19 19 19 19 Hang Dwg 400290-0001O0XX 400290-0001 0XX 400290-0001 OXX 400290-0001 OXX 400290-0001 OXX 400290-0001 OXX 400290-0001 OXX 400290-0001 OXX 400290-0001 0XX 400290-00010OXX 400290-00010OXX 400290-00010OXX 400290-00010OXX 400290-0001 0XX 400290-00010OXX 400290-0001 OXX AF9006HL5003 AF9006HL5015 AF9006HL5018 AF9006HL5035 AF9006HL5035 AF9008HL5028 AF9008HL5029 AF9008HL5030 AF9008HL5041 AF9008HL5041 AF9010HL5002 AF9010HL5002 AF9010HL5007 AF901OHL5007 Iso Dwg 400290--00010XX 400290--00010XX 400290--00010XX 400290--00010XX 400290--00010XX 400290--00010XX 400290--00010XX 400290--00010XX 400290--00010XX 400290--00010XX 400290--00010XX 400290--00010XX 400290--00010XX 400290--00010XX 400290--00010XX 400290--00010XX 2C369PAF402-02 2C369PAF402-02 2C369PAF402-02 2C369PAF402-02 2C369PAF402-02 2C369PAF402-02 2C369PAF402-02 2C369PAF402-02 2C369PAF402-02 2C369PAF402-02 2C369PAF402-01 2C369PAF402-01 2C369PAF402-01 2C369PAF402-01 Pipe Dwg 0957-0100008WN 0957-0100008WN 0957-0100008WN 0957-0100008WN 0957-0100008WN 0957-0100008WN 0957-0100008WN 0957-0100008WN 0957-0100008WN 0957-0100008WN 0957-0100008WN 0957-0100008WN 0957-0100008WN 0957-0100008WN 0957-0100008WN 0957-0100008WN F00024 F00024 F00024 F00024 F00024 F00024 F00024 F00024 F00024 F00024 F00024 F00024 F00024 F00024

Unit-1 Snubber IST Listing Pages 2 of 13 Mdtpns Tagtpns I Snubber AF1010HL5008L AF101OHL5008U AF1010HL5009 AF101OHL5017 AF101OHL5018 AF1010HL5020 AF1010HL5026 AF1010HL5035 AF1012HL5014E AF1012HL5014W AF1012HL5017 AF1012HL5018 AF101 2HL5020 AF101 2HL5024 AF1012HL5027 AF101 2HL5038L AF101 2HL5038U AF1054HL5004N AF1054HL5004S AF1061HL5001 AF1061HL5002 AF1062HL5011 AF1062HL5012 AF1062HL5015 AF1063HL5002 AF1063HL5003 AF1063HL5005 AF1063HL5006 AF1064HL5004 AP1003HF5001 Model No AD5501 AD5501 AD1601 AD5501 AD1601 AD1601 AD1601 AD1601 AD1601 AD1601 AD5501 AD1601 AD1601 AD5501 AD5501 AD5501 AD5501 AD151 AD151 AD1601 AD1601 AD1601 AD1601 AD1601 AD1601 AD151 AD1601 AD1601 AD1601 AD41 Qc Level 2

2 2

2 2

2 2

2 2

2 2

2 2

2 2

2 2

3 3

2 2

2 2

2 2

2 2

2 2

2 Route / Location RCB SGBC>68' RCB SGBC>68' RCB SGBC>68' RCB SGBC>68' RCB SGBC>68' RCB SGBC>68' RCB SGBC>19' RCB SGBC>68' RCB SGBC>68' RCB SGBC>68' RCB SGBC>68' RCB SGBC>68' RCB SGBC>68' RCB OMB >19' RCB OMB >19' RCB SGBC>68' RCB SGBC>68' IVC D IVC D RCB SGAD>52' RCB SGAD>68' RCB SGAD>68' RCB SGAD>68' RCB SGAD>52' RCB SGBC>68' RCB SGBC>68' RCB SGBC>68' RCB SGBC>68' RCB SGBC>52' MAB RM 108 Elev 19 19 19 19 19 19 19 19 19 19 19 19 19 19 19 19 19 34 34 19 19 19 19 19 19 19 19 19 19 29 Hang Dwg AF9010HL5008 AF9010HL5008 AF9010HL5009 AF901OHL5017 AF901OHL5018 AF9010HL5020 AF9010HL5026 AF9010HL5035 AF9012HL5014 AF9012HL5014 AF9012HL5017 AF9012HL5018 AF9012HL5020 AF9012HL5024 AF9012HL5027 AF9012HL5038 AF9012HL5038 AF9054H L5004 AF9054H L5004 AF9061HL5001 AF9061 HL5002 AF9062HL5011 AF9062HL5012 AF9062HL5015 AF9063HL5002 AF9063HL5003 AF9063HL5005 AF9063HL5006 AF9064HL5004 AP1003HF5001 Iso Dwg Pipe Dwg 2C369PAF402-01 F00024 2C369PAF402-01 F00024 2C369PAF402-01 F00024 2C369PAF402-01 F00024 2C369PAF402-01 F00024 2C369PAF402-01 F00024 2C369PAF402-01 F00024 2C369PAF402-01 F00024 2C369PAF402-01 F00024 2C369PAF402-01 F00024 2C369PAF402-01 F00024 2C369PAF402-01 F00024 2C369PAF402-01 F00024 2C369PAF402-01 F00024 2C369PAF402-01 F00024 2C369PAF402-01 F00024 2C369PAF402-01 F00024 5G369PAF602-1 0 F00024 5G369PAF602-1 0 F00024 2C369PAF402-02 F00024 2C369PAF402-02 F00024 2C369PAF402-02 F00024 2C369PAF402-02 F00024 2C369PAF402-02 F00024 2C369PAF402-01 F00024 2C369PAF402-01 F00024 2C369PAF402-01 F00024 2C369PAF402-01 F00024 2C369PAF402-01 F00024 5M369PAP287-A01 Z47501

Unit-1 Snubber IST Listing Pages 3 of 13 Mdtpns Tagtpns /

Snubber CC1i105HL5004 CC1105HL5009 CC1i109HL5001 N CC1i109HL5001 S CC1i 1OHL5001 CC1136HL5002 CC1205HL5007L CC1205HL5007U CC1206HL5008 CC1209HL5002 CC1209HL5003 CC121OHL5001 CC1215SS0002 CC1220SS0002L CC1 220SS0002U CC1309SS0002 CC01309SS0003L CC1309SS0003U CC1311SS0001 CC1320HL5001 CC1425HL5016 CC1613SS0003 CV1002HL5002 CV1002HL5003 CV1002HL5004 CV1002HL5007 CV1002HL5008 CV1002HL5009 CV1002HL5010 CV1002HL5012 Model No AD5501 AD5501 AD501 AD501 AD1601 AD501 AD501 AD501 AD501 AD 1601 AD1601 AD1601 AD501 AD501 AD501 AD1601 AD1601 AD1601 AD1601 AD1601 AD151 AD151 AD71 AD71 AD71 AD151 AD71 AD151 AD151 AD71 Qc Level 3

3 3

3 3

7 3

3 3

3 3

3 3

3 3

3 3

3 3

3 3

7 2

2 2

2 2

2 2

2 Route / Location RCB RHR HX 1A RCB OMB >52' MAB RM 106A MAB RM 106A MAB RM 106A MAB RM 64 RCB OMB >52' RCB OMB >52' RCB OMB >52' MAB RM 216 MAB RM 216 MAB RM 106A RCB OMB >-11 MAB RM 64 MAB RM 64 MAB RM 216 MAB RM 216 MAB RM 216 MAB RM 216 MAB RM 216 FHB RM 208 RCB OMB >37' RCB SGBC>52' RCB SGBC>19' RCB SGBC>19' RCB SGBC>19' RCB SGBC>37' RCB SGBC>37' RCB SGBC>19' RCB SGBC>37' Elev 37 52 27 27 27 10 52 52 52 41 41 27

-11 10 10 41 41 41 41 41 30 37 19 19 19 19 19 19 19 19 Hang Dwg CC9105HL5004 CC9105HL5009 CC9109HL5001 CC9109HL5001 CC91 1OH L5001 CC9136HL5002 CC9205HL5007 CC9205HL5007 CC9206HL5008 CC9209HL5002 CC9209HL5003 CC9210HL5001 CC9215SS0002 CC9220SS0002 CC9220SS0002 CC9309SS0002 CC9309SS0003 CC9309SS0003 CC9311SS0001 CC9320HL5001 CC9425HL5016 CC9613SS0003 CV9002HL5002 CV9002HL5003 CV9002HL5004 CV9002HL5007 CV9002HL5008 CV9002HL5009 CV9002HL5010 CV9002HL5012 Iso Dwg 4C369PCC407-08 4C369PCC407-08 5M361 PCC207-07 5M361 PCC207-07 5M361 PCC207-07 5M361 PCC207-07 4C369PCC407-07 4C369PCC407-07 4C369PCC407-1 0 5M369PCC207-11 5M369PCC207-11 5M369PCC207-22 3C369PCC407-16 5M369PCC207-11 5M369PCC207-11 5M361 PCC207-01 5M361 PCC207-01 5M361 PCC207-01 5M369PCC207-08 5M361 PCC207-01 5M361 PCC207-01 5C369PCC407-03 4C369PCV417-04 4C369PCV417-04 4C369PCV417-04 4C369PCV417-04 4C369PCV417-04 4C369PCV417-04 4C369PCV417-04 4C369PCV417-04 Pipe Dwg F05017 F05017 F05017 F05017 F05017 F05017 F05018 F05018 F05018 F05018 F05018 F05018 F05018 F05018 F05018 F05019 F05019 F05019 F05019 F05019 F05020 F05021 F05005 F05005 F05005 F05005 F05005 F05005 F05005 F05005

Unit-1 Snubber IST Listing Pages 4 of 13 Mdtpns Tagtpns /

Snubber CV1002HL5019 CV1002HL5020 CV1002HL5021 CV1003HF5003 CV1003HL5003N CV1003HL5003S CV1004HF5001 CV1005HF5001 CV1006HL5037L CV1006HL5037U CV1011H L5009 CV1086SS0002 CV1088HL5002 CV11 16HL5018 CV1117HF5054 CV1i117HL5005 CV1117SS0006 CV1i121 HS5007 CV1121HS5009 CV1121HS5010 FC1009SS0001 FC 1011 HL5001 FC101 2HL5002 FW1012HL5002E FW1012HL5002W FW1012HL5003 FW1012HL5005L FW101 2HL5005U FW1012HL5011 FW1012HL5016 Model No AD151 AD151 AD501 AD151 AD151 AD151 AD41 AD41 AD151 AD151 AD71 AD71 AD41 AD71 AD41 AD501 AD1601 AD41 AD151 AD151 AD41 AD1601 AD501 AD5501 AD5501 AD12501 AD5501 AD5501 AD5501 AD12501 Qc Level 2

2 2

2 2

2 2

2 2

2 2

2 2

2 2

2 21 1

1 3

2 3

2 2

2 2

2 2

2 Route / Location RCB SGBC>19' RCB SGBC>19' RCB SGBC>19' RCB RGN HX RCB RGN HX RCB RGN HX RCB RGN HX RCB RGN HX MAB RM 108 MAB RM 108 MAB RM 49 MAB RM 110 MAB RM 31 MAB RM 108 RCB PZR RCB SGBC>37' RCB SGBC>37' RCB PZR RCB PZR RCB PZR FHB RM 110 FHB RM 110 FHB RM 110 RCB SGAD>37' RCB SGAD>37' RCB SGAD>37' RCB OMB >37' RCB OMB >37' RCB SGAD>19' RCB SGAD>37' Elev 19 19 19 37 37 37 37 37 29 29 10 29 10 29 37 19 19 37 37 37 21 21 21 19 19 19 37 37 19 19 Hang Dwg CV9002HL5019 CV9002HL5020 CV9002HL5021 CV1003HF5003 CV2003HL5003 CV1003HL5003 CV1004HF5001 CV1005HF5001 CV9006HL5037 CV9006HL5037 CV901 1 HL5009 CV9086SS0002 CV9088HL5002 CV9116HL5018 CV1i117HF5054 CV9117HL5005 CV9117SS0006 CV9121 HS5007 CV9121 HS5009 CV9121 HS501 0 FC9009SS0001 FC901 1 HL5001 FC9012HL5002 FW9012HL5002 FW9012HL5002 FW9012HL5003 FW9012HL5005 FW9012HL5005 FW9012HL5011 FW1012HL5016 Iso Dwg Pipe Dwg 4C369PCV417-04 F05005 4C369PCV417-04 F05005 4C369PCV417-04 F05005 5C369PCV417-A09 F05005 4C369PCV417-04 F05005 4C369PCV417-04 F05005 5C369PCV417-A09 F05005 5C369PCV417-A09 F05005 4M369PCV217-04 4M369PCV217-04 4M369PCV217-04 F05006 2M369PCV217-05 F05006 4M369PCV217-04 F05006 2M369PCV217-20 F05007 4C369PCV417-A02 F05005 4C369PCV417-02 F05005 4C369PCV417-02 F05005 4C369PCV417-A02 F05005 4C369PCV417-A02 F05005 4C369PCV417-A02 F05005 4F369PFC530-03 F05028 4F369PFC530-02 F05028 4F369PFC530-02 F05028 2C369PFW433-01 F00062 2C369PFW433-01 F00062 2C369PFW433-01 F00062 2C369PFW433-01 F00062 2C369PFW433-01 F00062 2C369PFW433-01 F00062 2C369PFW433-01 F00062

Unit-1 Snubber IST Listing Pages 5 of 13 Mdtpns Tagtpns /

Snubber FW1014HL5001E FW1014HL5001W FW1014HL5002 FW1014HL5003L FW1014HL5003U FW1014HL5009 FW1014HL5012 FW1016HL5003 FW1016HL5004 FW1016HL5006 FW1016HL5007 FW1016HL5008 FW1016HL5009 FW1016HL5010 FW1016SH0001 FW1016SS0006 FW1018HL5003 FW1018HL5004 FW1018HL5006L FW1018HL5006U FW1018HL5007N FW1018HL5007S FW101 8HL5008 FW1018HL5009 FW1018SS0001 FW1018SS0006 FW1018SS0007 FW1029HL5002E FW1029HL5002W FW1029HL5003 Model No AD5501 AD5501 AD12501 AD5501 AD5501 AD12501 AD5501 AD5501 AD5501 AD5501 AD5501 AD5501 AD12501 AD5501 AD5501 AD5501 AD5501 AD5501 AD5501 AD5501 AD5501 AD5501 AD12501 AD12501 AD5501 AD5501 AD12501 AD1601 AD1601 AD1601 Qc Level 2

2 2

2 2

2 2

2 2

2 2

2 2

2 2

2 2

2 2

2 2

2 2

2 2

2 2

2 2

2 Route / Location Elev RCB SGBC>37' RCB SGBC>37' RCB SGBC>37' 19 RCB RGN HX 37 RCB RGN HX 37 RCB SGBC>37' 19 RCB SGBC>19' 19 RCB RGN HX 37 RCB SGBC>19' 19 RCB SGBC>52' 19 RCB SGBC>19' 19 RCB RGN HX 37 RCB SGBC>37' 19 RCB SGBC>37' 19 RCB SGBC>37' 19 RCB SGBC>52' 19 RCB OMB >37' 37 RCB SGAD>19' 19 RCB OMB >37' 37 RCB OMB >37' 37 RCB SGAD>37' 19 RCB SGAD>37' 19 RCB SGAD>37' 19 RCB SGAD>37' 19 RCB SGAD>19' 19 RCB SGAD>52' 19 RCB SGAD>37' 19 IVC A 44 IVC A 44 IVC A 44 Hang Dwg FW9014HL5001 FW9014HL5001 FW9014HL5002 FW9014HL5003 FW9014HL5003 FW9014HL5009 FW9014HL5012 FW9016HL5003 FW9016HL5004 FW9016HL5006 FW9016HL5007 FW9016HL5008 FW9016HL5009 FW9016HL5010 FW9016SHOO01 FW9016SS0006 FW9018HL5003 FW9018HL5004 FW9018HL5006 FW9018HL5006 FW9018HL5007 FW9018HL5007 FW9018HL5008 FW9018HL5009 FW9018SS0001 FW9018SS0006 FW9018SS0007 FW9029HL5002 FW9029HL5002 FW9029HL5003 Iso Dwg 2C369PFW433-01 2C369PFW433-01 2C369PFW433-01 2C369PFW433-01 2C369PFW433-01 2C369PFW433-01 2C369PFW433-01 2C369PFW433-11 2C369PFW433-01 2C369PFW433-01 2C369PFW433-01 2C369PFW433-01 2C369PFW433-01 2C369PFW433-01 2C369PFW433-01 2C369PFW433-01 2C369PFW433-01 2C369PFW433-01 2C369PFW433-01 2C369PFW433-01 2C369PFW433-01 2C369PFW433-01 2C369PFW433-01 2C369PFW433-01 2C369PFW433-01 2C369PFW433-01 2C369PFW433-01 2G369PFW633-02 2G369PFW633-02 2G369PFW633-02 Pipe Dwg F00062 F00062 F00062 F00062 F00062 F00062 F00062 F00062 F00062 F00062 F00062 F00062 F00062 F00062 F00062 F00062 F00062 F00062 F00062 F00062 F00062 F00062 F00062 F00062 F00062 F00062 F00062 F00062 F00062 F00062

Unit-1 Snubber IST Listing Pages 6 of 13 Mdtpns Tagtpns /

Snubber FW1030HL5002E FW1030HL5002W FW1030HL5003 FW1031HL5002E FW1031HL5002W FW1031HL5003 FW1032HL5002E FW1032HL5002W FW1032HL5003 FW1 1 17HL5001 FW1 1 17HL5003 FW1 1 17HL5004 FWI 1 19HL5001 FW1 1 19HL5003 FW1 1 19HL5004 FW1 121 HL5001 FW1 121H L5003 FW1 121 H L5004 FW1 123H L5001 FW1 123H L5003 FW 123HL5004 MD1 147HF5002 MD1 148HF5002 MD1 149HF5002 MDI 150HF5002 MS1001HL5004 MS1001HL5007 MS1001HL5010L MS1001HL5010U MS1001HL501 1E Model No AD1601 AD1601 AD1601 AD1601 AD1601 AD1601 AD1601 AD1601 AD1601 AD41 AD41 AD41 AD41 AD41 AD41 AD41 AD41 AD41 AD41 AD41 AD41 AD71 AD71 AD71 AD41 AD5501 AD12501 AD1601 AD1601 AD5501 Qc Level 2

2 2

2 2

2 2

2 2

2 2

2 2

2 2

2 2

2 2

2 2

7 7

7 7

2 2

2 2

2 Route / Location Elev IVC B 44 IVC B 44 IVC B 44 IVC C 44 IVC C 44 IVC C 44 IVC D 44 IVC D 44 IVC D 44 IVC C 34 IVC C 34 IVC C 44 IVC B 34 IVC B 34 IVC B 44 IVC A 34 IVC A 34 IVC A 34 IVC D 34 IVC D 34 IVC D 34 IVC A 44 IVC B 44 IVC C 44 IVC D 44 RCB OMB >68' 68 RCB SGAD>68' 19 IVC A 51 IVC A 51 IVC A 51 Hang Dwg FW9030H L5002 FW9030HL5002 FW9030HL5003 FW9031 HL5002 FW9031 HL5002 FW9031 HL5003 FW9032 H L5002 FW9032HL5002 FW9032HL5003 FW9117HL5001 FW9117HL5003 FW9117HL5004 FW9119HL5001 FW9119HL5003 FW9119HL5004 FW9121 HL5001 FW9121 HL5003 FW9121 HL5004 FW9123HL5001 FW9123HL5003 FW9123HL5004 MD1 147HF5002 MD1 148HF5002 MD1 149HF5002 MD1 150HF5002 MS9001 HL5004 MS9001 HL5007 MS9001 HL5010 MS9001HL5010 MS9001HL5011 Iso Dwg Pipe Dwg 2G369PFW633-03 F00062 2G369PFW633-03 F00062 2G369PFW633-03 F00062 2G369PFW633-04 F00062 2G369PFW633-04 F00062 2G369PFW633-04 F00062 2G369PFW633-01 F00062 2G369PFW633-01 F00062 2G369PFW633-01 F00063 2G369PFW633-05 F00063 2G369PFW633-05 F00063 2G369PFW633-05 F00063 2G369PFW633-05 F00063 2G369PFW633-05 F00063 2G369PFW633-05 F00063 2G369PFW633-05 F00063 2G369PFW633-05 F00063 2G369PFW633-05 F00063 2G369PFW633-05 F00063 2G369PFW633-05 F00063 2G369PFW633-05 F00063 9G369PMD645-AO1 F00055 9G369PMD645-AO1 F00055 9G369PMD645-AO1 F00055 9G369PMD645-AO1 F00055 2C369PMS446-01 F00016 2C369PMS446-01 F00016 2G369PMS646-06 F00016 2G369PMS646-06 F00016 2G369PMS646-06 F00016

Unit-1 Snubber IST Listing Pages 7 of 13 Mdtpns Tagtpns /

Snubber MS1001HL501 1W MS1001HL5012L MS1001HL5012U MS1001HL5015 MS1002HL5006 MS1002HL5007 MS1002HL5010L MS1002HL501OU MS1 002HL501 1 E MS1002HL501 1W MS1002HL5012L MS1002HL5012U MS1002HL5015 MS1002HL5016 MS1003HL5004 MS1003HL5012 MS1003HL5013 MS1003HL5014 MS1003HL5015L MS1003HL5015U MS1003HL5016E MS1003HL5016W MS1003HLL5017L MS1003HL5017U MS1004HL5007 MS1004HL5012 MS1004HL5013 MS1004HL5014 MS1004HL5015L MS1004HL5015U Model No AD5501 AD1601 AD1601 AD5501 AD5501 AD12501 AD1601 AD1601 AD5501 AD5501 AD1601 AD1601 AD5501 AD5501 AD5501 AD12501 AD5501 AD5501 AD1601 AD1601 AD5501 AD5501 AD1601 AD1601 AD5501 AD12501 AD12501 AD12501 AD1601 AD1601 Qc Level 2

2 2

2 2

2 2

2 2

2 2

2 2

2 2

2 2

2 2

2 2

2 2

2 2

2 2

2 2

2 Route / Location IVC A IVC A IVC A RCB SGAD>83' RCB OMB >68' RCB SGBC>68' IVC B IVC B IVC B IVC B IVC B IVC B RCB SGBC>83' RCB SGBC>83' RCB OMB >68' RCB SGBC>68' RCB SGBC>83' RCB SGBC>83' IVC C IVC C IVC C IVC C IVC C IVC C RCB OMB >68' RCB SGAD>68' RCB PZR RCB SGAD>83' IVC D IVC D Elev 51 51 51 19 68 19 51 51 51 51 51 51 19 19 68 19 19 19 51 51 51 51 51 51 68 19 37 19 51 51 Hang Dwg MS9001 HL501 1 MS9001 HL5012 MS9001 HL5012 MS9001 HL5015 MS9002HL5006 MS9002HL5007 MS9002HL5010 MS9002HL5010 MS9002HL5011 MS9002HL5011 MS9002HL5012 MS9002HL5012 MS9002HL5015 MS9002HL5016 MS9003HL5004 MS9003HL5012 MS9003HL5013 MS9003HL5014 MS9003HL5015 MS9003HL5015 MS9003HL5016 MS9003HL5016 MS9003HL5017 MS9003HL5017 MS9004HL5007 MS9004HL5012 MS9004HL5013 MS9004HL5014 MS9004HL5015 MS9004HL5015 Iso Dwg 2G369PMS646-06 2G369PMS646-06 2G369PMS646-06 2C369PMS446-01 2C369PMS466-02 2C369PMS446-02 2G369PMS646-07 2G369PMS646-07 2G369PMS646-07 2G369PMS646-07 2G369PMS646-07 2G369PMS646-07 2C369PMS446-02 2C369PMS446-02 2C369PMS446-03 2C369PMS446-03 2C369PMS446-03 2C369PMS446-03 2G369PMS646-08 2G369PMS646-08 2G369PMS646-08 2G369PMS646-08 2G369PMS646-08 2G369PMS646-08 2C369PMS446-04 2C369PMS446-04 2C369PMS446-04 2C369PMS446-04 2G369PMS646-09 2G369PMS646-09 Pipe Dwg F00016 F00016 F00016 F00016 F00016 F00016 F00016 F00016 F00016 F00016 F00016 F00016 F00016 F00016 F00016 F00016 F00016 F00016 F00016 F00016 F00016 F00016 F00016 F00016 F00016 F00016 F00016 F00016 F00016 F00016

Unit-1 Snubber IST Listing Pages 8 of 13 Mdtpns Tagtpns /

Snubber MS1004HL5016E MS1004HL5016W MS1004HL5017L MS1004HL5017U MS1005SS0001 N MS1005SS0001S MS1005SS0002E MS1005SS0002W MS1006SS0001 N MS1006SS0001S MS1006SS0002E MS1006SS0002W MS1007SS0002E MS1 007SS0002W MS1008HL5001 MS1 008SS0001 E MS1008SS0001W MS101 3HL5002E MS101 3HL5002W MS1013HL5003 MS1013HL5004 MS1013SS0002E MS1013SS0002W MS1 051 HL5009 PS1020HF5002 RC100OSS0001 RC1003HL5006 RC1003HL5009 RC1014HL5001 RC1014HL5003E Model No AD5501 AD5501 AD1601 AD1601 AD5501 AD5501 AD5501 AD5501 AD5501 AD5501 AD5501 AD5501 AD5501 AD5501 AD5501 AD5501 AD5501 AD5501 AD5501 AD5501 AD5501 AD5501 AD5501 AD71 AD41 AD151 AD501 AD501 AD5501 AD5501 Qc Level 2

2 2

2 7

7 7

7 7

7 7

7 7

7 7

7 7

7 7

7 7

7 7

3 7

1 1

1 7

7 Route / Location IVC D IVC D IVC D IVC D TGB B TGB B TGB B TGB B TGB B TGB B TGB B TGB B TGB B TGB B TGB B TGB B TGB B TGB B TGB B TGB B TGB B TGB B TGB B IVC D MAB RM 108 RCB PZR RCB PZR RCB PZR RCB PZR RCB PZR Elev 51 51 51 51 55 55 29 29 55 55 29 29 29 29 55 29 29 55 55 55 55 55 55 10 29 37 37 37 37 37 Hang Dwg MS9004HL5016 MS9004HL5016 MS9004HL5017 MS9004HL5017 MS9005SS0001 MS9005SS0001 MS9005SS0002 MS9005SS0002 MS9006SS0001 MS9006SS0001 MS9006SS0002 MS9006SS0002 MS9007SS0002 MS9007SS0002 MS9008HL5001 MS9008SS0001 MS9008SS0001 MS9013HL5002 MS9013HL5002 MS9013HL5003 MS9013HL5004 MS9013SS0002 MS9013SS0002 MS9051 HL5009 PS1020HF5002 RC9000SS0001 RC9003HL5006 RC9003HL5009 RC9014HL5001 RC9014HL5003 Iso Dwg 2G369PMS646-09 2G369PMS646-09 2G369PMS646-09 2G369PMS646-09 7G369PMS846-05 7G369PMS846-05 7G369PMS846-05 7G369PMS846-05 7G369PMS846-06 7G369PMS846-06 7G369PMS846-06 7G369PMS846-06 7G369PMS846-06 7G369PMS846-06 7G369PMS846-05 7G369PMS846-05 7G369PMS846-05 7G369PMS846-08 7G369PMS846-08 7G3G9PMS846-05 7G369PMS846-05 7G369PMS846-09 7G369PMS846-09 4G369PMS646-05 5M369PPS285-AO1 4C369PRC457-07 1C369PRC457-06 1C369PRC457-06 7C369PRC457-02 7C769PRC457-02 Pipe Dwg F00016 F00016 F00016 F00016 F00016 F00016 F00016 F00016 F00016 F00016 F00016 F00016 F00016 F00016 F00016 F00016 F00016 F00016 F00016 F00016 F00016 F00016 F00016 F00024 Z00045 F05003 F05003 F05003 F05004 F05004

Unit-1 Snubber IST Listing Pages 9 of 13 Mdtpns Tagtpns /

Snubber RC1014HL5003W RC1014HL5005N RC1014HL5005S RC1014HL5006L RC1014HL5006U RC1014HL5009 RC1014HL5012N RC1014HL5012S RC1014HL5013 RC1014HL5015 RC1014HL5019N RC1014HL5019S RC1014HL5026.

RC1014HL5028 RC1 1 12HL5002 RC1 123HL5013 RC1 125HL5001 RC1 125HL5008 RC1221 H L5001 RC1221HL5003 RC1221HL5004 RC1221HL5005 RC1221HL5006 RC1221HL5007 RC1320HL5002 RC1320HL5004 RC1422HL5019 RH1 101 HL5001 RH1101HL5002 RH1101HL5003 Qc Level Route / Location Elev Model No AD5501 AD5501 AD5501 AD5501 AD5501 AD501 AD5501 AD5501 AD1601 AD1601 AD5501 AD5501 AD501 AD1601 AD5501 AD501 AD5501 AD1601 AD1601 AD5501 AD5501 AD5501 AD5501 AD5501 AD1601 AD501 AD501 AD1601 AD1601 AD1601 RCB PZR RCB PZR RCB PZR RCB PZR RCB PZR RCB PZR RCB PZR RCB PZR RCB PZR, RCB PZR RCB PZR RCB PZR RCB PZR RCB PZR RCB SGAD>19' RCB PZR RCB IMB >-11 RCB IMB >-11 RCB IMB >-11 RCB IMB >-11 RCB SGBC>19' RCB SGBC>19' RCB IMB >-11 RCB IMB >-11 RCB SGBC>19' RCB SGBC>19' RCB SGAD>52' RCB VLV RM RCB VLV RM RCB VLV RM 37 37 37 37 37 37 37 37 37 37 19 19 19 19 19 37

-11

-11

-11

-11 19 19

-11

-11 19 19 19

-2

-2 19 Hang Dwg RC9014HL5003 RC9014HL5005 RC9014HL5005 RC9014HL5006 RC9014HL5006 RC9014HL5009 RC9014HL5012 RC9014HL5012 RC9014HL5013 RC9014HL5015 RC9014HL5019 RC9014HL5019 RC9014HL5026 RC9014HL5028 RC9112HL5002 RC9123HL5013 RC9125HL5001 RC9125HL5008 RC9221 HL5001 RC9221 HL5003 RC9221 HL5004 RC9221 HL5005 RC9221 HL5006 RC9221 HL5007 RC9320HL5002 RC9320HL5004 RC9422HL5019 RH91 01 HL5001 RH91 01 HL5002 RH9101HL5003 Iso Dwg 7C369PRC457-02 7C369PRC457-02 7C369PRC457-02 7C369PRC457-02 7C369PRC457-02 7C369PRC457-02 7C369PRC457-02 7C369PRC457-02 7C369PRC457-02 7C369PRC457-02 7C369PRC457-02 7C369PRC457-02 7C369PRC457-02 7C369PRC457-02 4C369PRC457-09 4C369PRC457-07 4C369PRC457-10 4C369PRC457-10 4C369PRC457-10 4C369PRC457-10 4C369PRC457-10 4C369PRC457-10 4C369PRC457-1 0 4C369PRC457-10 4C369PRC457-04 4C369PRC457-04 1C369PRC457-06 4C369PRH459-04 4C369PRH459-04 4C369PRH459-04 Pipe Dwg F05004 F05004 F05004 F05004 F05004 F05004 F05004 F05004 F05004 F05004 F05004 F05004 F05004 F05004 F05001 F05001 F05001 F05001 F05001 F05001 F05001 F05001 F05001 F05001 F05001 F05001 F05001 F20000 F20000 F20000

Unit-1 Snubber IST Listing Pages 10 of 13 Mdtpns Tagtpns /

Snubber RH1101HL5006 RH1101HL5009 RH1110HL5002 RH1201HL5001 RH1201HL5006 RH1202SS0002 RH1203HL5001 RH1204HL5001 RH1211 HL5002L RH121 1 HL5002U RH1303HL5007 RH1303HL5009 RH1306SS0001 RH1312HL5002 RH1313HL5003L RH1313HL5003U SB1101HL5007 SB1 101HL5012 SB1 101HL5017 SB1101HL5019 SB1101HL5020 SB1101HL5022 SB 104HL5001 SB1104HL5002 SB1104HL5006 SB 105HL5001 SB1107HF5001 SB1201HL5004 SB1201HL5010 SB1201HL5013 Model No AD5501 AD1601 AD501 AD1601 AD5501 AD1601 AD501 AD501 AD501 AD501 AD501 AD501 AD501 AD501 AD501 AD501 AD1601 AD501 AD1601 AD501 AD501 AD501 AD501 AD501 AD501 AD71 AD41 AD1601 AD1601 AD501 Qc Level 1

1 2

1 1

2 2

2 2

2 2

2 2

2 2

2 2

2 2

2 2

2 7

7 7

7 2

2 2

2 Route / Location RCB SGAD>19' RCB SGAD>19' RCB SGAD>19' RCB VLV RM RCB VLV RM RCB VLV RM RCB VLV RM RCB VLV RM RCB SGBC>19' RCB SGBC>19' RCB VLV RM RCB VLV RM RCB VLV RM RCB VLV RM RCB SGBC>19' RCB SGBC>19' RCB OMB >19' RCB SGAD>19' RCB OMB >19' IVC A IVC A IVC A IVC A IVC A IVC A IVC A IVC A RCB OMB >19' RCB OMB >19' RCB SGBC>19' Elev 19 19 19

-2

-2

-2 19 19 19 19 19

-2

-2 19 19 19 19 19 19 10 10 10 10 10 10 10 10 19 19 19 Hang Dwg RH9101HL5006 RH9101 HL5009 RH91 10HL5002 RH9201 HL5001 RH9201 HL5006 RH9202SS0002 RH9203HL5001 RH9204HL5001 RH921 1 HL5002 RH921 1 HL5002 RH9303HL5007 RH9303HL5009 RH9306SS0001 RH9312HL5002 RH9313HL5003 RH9313HL5003 SB9101 HL5007 SB9101 HL5012 SB9101HL5017 SB9101HL5019 SB9101 HL5020 SB9101 HL5022 SB9104HL5001 SB9104HL5002 SB9104HL5006 SB9105HL5001 SB1 107HF5001 SB9201 HL5004 SB9201 HL501 0 SB9201 HL5013 Iso Dwg 4C369PRC459-04 4C369PRH459-04 4C369PRH459-03 4C369PRH459-07 4C369PRH459-07 4C369PRH459-07 2C369PRH459-02 2C369PRH459-02 4C369PRH459-07 4C369PRH459-07 2C369PRH459-05 2C369PRH459-05 4C369PRH459-06 4C369PRH459-01 4C369PRH459-06 4C369PRH459-06 2C369PSB468-02 2C369PSB468-02 2C369PSB468-02 5G369PSB668-03 5G369PSB668-03 5G369PSB668-03 5G369PSB668-03 5G369PSB668-03 5G369PSB668-03 5G369PSB668-03 7G369PSB668-AO1 2C369PSB468-02 2C369PSB468-02 2C369PSB468-02 Pipe Dwg F20000 F20000 F20000 F20000 F20000 F20000 F20000 F20000 F20000 F20000 F20000 F20000 F20000 F20000 F20000 F20000 F20001 F20001 F20001 F20001 F20001 F20001 F20001 F20001 F20001 F20001 F20001 F20001 F20001 F20001

Unit-1 Snubber IST Listing Pages 11 of 13 Mdtpns Tagtpns /

Snubber SB1201HL5017 SB1201HL5018 SB1201HL5020 SB1202HF5002 SB1204HL5001 SB1204HL5002 SB1205HL5003 SB1207HF5001 SB1250HF5003 SB1274HL5002L SB1274HL5002U SB1301HL5003L SB1301 HL5003U SB1 301 HL501 1 L SB1 301 HL501 1 U SB1301HL5012N SB1301HL5012S SB1301HL5018 SB1301HL5020 SB1301HL5021 SB1302HF5003 SB1303HF5005 SB1304HL5001 SB1304HL5002 SB1304HL5006 SB1350HF5016 SB1401 HL5003 SB1401HL5011 SB1401HL5012 SB1401HL5016L Model No AD501 AD501 AD501 AD71 AD501 AD501 AD151 AD41 AD41 AD151 AD151 AD501 AD501 AD501 AD501 AD151 AD151 AD501 AD501 AD501 AD41 AD151 AD501 AD501 AD501 AD41 AD1601 AD1601 AD501 AD151 Qc Level 2

2 2

2 7

7 7

7 2

7 7

2 2

2 2

2 2

2 2

2 2

2 7

7 7

2 2

2 2

2 Route / Location IVC B IVC B IVC B RCB SGBC>19' IVC B IVC B IVC B IVC B RCB SGBC>19' IVC B IVC B RCB OMB >19' RCB OMB >19' RCB SGBC>19' RCB SGBC>19' RCB SGBC>19' RCB SGBC>19' IVC C IVC C IVC C RCB SGBC>19' RCB SGBC>37' IVC C IVC C IVC C RCB SGBC>19' RCB OMB >19' RCB OMB >19' RCB SGAD>19' RCB SGAD>19' Elev 10 10 10 19 10 10 10 10 19 10 10 19 19 19 19 19 19 10 10 10 19 19 10 10 10 19 19 19 19 19 Hang Dwg SB9201 HL5017 SB9201 HL5018 SB9201HL5020 SB1202HF5002 SB9204HL5001 SB9204HL5002 SB9205HL5003 SB1207HF5001 SB1250HF5003 SB9274HL5002 SB9274HL5002 SB9301 HL5003 SB9301 HL5003 SB9301HL5011 SB9301HL5011 SB9301 HL5012 SB9301 HL5012 SB9301HL5018 SB9301 HL5020 SB9301HL5021 SB1302HF5003 SB1303HF5005 SB9304HL5001 SB9304HL5002 SB9304HL5006 SB1350HF5016 SB9401 HL5003 SB9401HL5011 SB9401 HL5012 SB9401 HL5016 Iso Dwg Pipe Dwg 5G369PSB668-05 F20001 5G369PSB668-05 720001 5G369PSB668-05 F20001 2C361 PSB468-A05 F20001 5G369PSB668-05 F20001 5G369PSB668-05 F20001 5G369PSB668-05 F20001 7G369PSB668-AO1 F20001 2C361 PSB468-A05 F20001 5G369PSB668-05 F20002 5G369PSB668-05 F20002 2C369PSB468-02 F20001 2C369PSB468-02 F20001 2C369PSB468-02 F20001 2C369PSB468-02 F20001 2C369PSB468-02 F20001 2C369PSB468-02 F20001 5G369PSB668-07 F20001 5G369PSB668-07 F20001 5G369PSB668-07 F20001 2C369PSB468-A04 F20001 2C369PSB468-A04 F20001 5G369PSB668-07 F20001 5G369PSB668-07 F20001 5G369PSB668-07 F20001 2C361 PSB468-A05 F20001 2C369PSB468-02 F20001 2C369PSB468-02 F20001 2C369PSB468-02 F20001 2C369PSB468-02 F20001

Unit-1 Snubber IST Listing Pages 12 of 13 Mdtpns Tagtpns /

Snubber SB1401HL5016U SB1401HL5019 SB1401HL5020 SB1401 HL5022 SB1401 HL5023 SB1402HF5002 SB1402HF5004 SB1403HF5002 SB1404HL5001 SB1404HL5002 SB1406HL5007 SB1407HF5001 SB1474HL5002 S11101 SS0008L S11101 SS0008U SI1 107HL5001 N SIl 107HL5001S SI1 107SS0061 SI1 108HL5001 Sil 108HL5003 SIl1 12HF5023 S11201 HL501OL S11201 HL501OU SI 1205HL5022 SI1206HL5008 S11206HL5012 SI1207SS0001 S11208HL5005 S11217HL5009 S11301SS0005L Model No AD151 AD501 AD501 AD501 AD501 AD71 AD71 AD71 AD501 AD501 AD41 AD41 AD501 AD501 AD501 AD501 AD501 AD501 AD1601 AD1601 AD41 AD501 AD501 AD501 AD151 AD501 AD501 AD1601 AD1601 AD501 Qc Level 2

2 2

2 2

2 2

2 7

7 7

7 7

2 2

2 2

21 1

7 2

2 2

2 2

2 1

2 2

Route / Location RCB SGAD>19' RCB SGAD>19' IVC D IVC D IVC D RCB SGAD>37' RCB SGAD>37' RCB SGAD>19' IVC D IVC D IVC D IVC D IVC D FHB HHSI A FHB HHSI A RCB OMB >19' RCB OMB >19' RCB OMB >19' RCB SGAD>19' RCB SGAD>19' RCB OMB >19' FHB HHSI B FHB HHSI B RCB IMB >-11 RCB IMB >-11 RCB IMB >-11 RCB OMB >19' RCB SGBC>19' RCB OMB >-11 FHB HHSI C Elev 19 19 10 10 10 19 19 19 10 10 10 10 10

-29

-29 19 19 19 19 19 19

-29

-29

-11

-11

-11 19 19

-2

-29 Hang Dwg SB9401 HL5016 SB9401 HL5019 SB9401 HL5020 SB9401 HL5022 SB9401 HL5023 SB1402HF5002 SB1402HF5004 SB1403HF5002 SB9404HL5001 SB9404HL5002 SB9406HL5007 SB1407HF5001 SB9474HL5002 S191 01 SS0008 S191 01 SS0008 S19107HL5001 S19107HL5001 S19107SS0061 S19108HL5001 S19108HL5003 S111 12HF5023 S19201HL5010 S19201 HL501 0 S19205HL5022 S19206HL5008 S19206HL5012 S19207SS0001 S19208HL5005 S19217HL5009 S19301 SS0005 Iso Dwg Pipe Dwg 2C369PSB468-02 F20001 2C369PSB468-02 F20001 5G369PSB668-01 F20001 5G369PSB668-01 F20001 5G369PSB668-01 F20001 2C369PSB468-A04 F20001 2C369PSB468-A04 F20001 2C368PSB468-A04 F20001 5G369PSB668-01 F20001 5G369PSB668-01 F20001 5G369PSB668-01 F20001 7G369PSB668-AO1 F20001 5G369PSB668-01 F20002 2F369PS1572-03 F05013 2F369PS1572-03 F05013 4C369PS1472-01 F05013 4C369PS1472-01 F05013 4C369PS1472-01 F05013 4C369PS1472-01 F05013 4C369PS1472-01 F05013 5C369PS1472-A07 F05013 2F369PS1572-04 F05014 2F369PS1572-04 F05014 2C369PS1472-02 F05014 4C369PS1472-05 F05014 4C369PS1472-05 F05014 4C369PS1472-05 F05014 4C369PS1472-05 F05014 5C369PS1472-03 F05016 2F369PS1572-06 F05015

Unit-1 Snubber IST Listing Pages 13 of 13 Mdtpns Tagtpns /

Snubber S11301 SS0005U SI1306HL5012 SI1308HL5001 SI1314HL5007 S11315HL5003 S11315HL5004 SI1326HL5001 SI1327HL5001 WL1019HF5001 WL1284HL5002 WL1284HL5003 Qc Level Route / Location Elev Model No AD501 AD151 AD501 AD5501 AD 12501 AD5501 AD501 AD1601 AD71 AD1601 AD501 2

2 1

21 1

2 2

7 7

7 FHB HHSI C FHB HHSI C RCB IMB >-11 RCB IMB >-11 RCB SGBC>19' RCB SGBC>19' RCB SGBC>19' RCB SGBC>19' RCB IMB >-11 MAB RM 67C MAB RM 53B

-29

-29

-11

-11 19 19 19 19

-11 10 10 Hang Dwg S19301 SS0005 S19306HL5012 S19308HL5001 S19314HL5007 S19315HL5003 S19315HL5004 S19326HL5001 S19327HL5001 WL1019HF5001 WL9284HL5002 WL9284HL5003 Iso Dwg Pipe Dwg 2F369PS1572-06 F05015 2F369PS1572-05 F05015 4C369PS1472-07 F05015 5C369PSI472-03 F05016 5C369PS1472-03 F05016 5C369PS1472-03 F05016 4C369PS1472-07 F05015 4C369PS1472-07 F05015 7G369PWL477-A03 F05022 7M369PWL277-03 F05026 7M369PWL277-03 F05026

ATTACHMENT 2 Unit 2 Snubber IST Listing Revision 0

Unit-2 Snubber IST Listing Pages 1 of 13 Mdtpns Tagtpns I Snubber 2C1 12XSNO001A 2C1 12XSN0001 B 2C1 12XSNO001C 2C1 12XSNO001D 2C1 12XSN0002A 2C1 12XSN0002B 2C1 12XSNO002C 2C1 12XSNO002D 2C1 12XSN0003A 2C1 12XSN0003B 2C1 12XSN0003C 2C1 12XSNO003D 2C112XSNO004A 2C1 12XSNO004B 2C1 12XSN0004C 2C1 12XSN0004D AF2006HL5003 AF2006HL5015 AF2006HL5018 AF2006HL5035N AF2006HL5035S AF2008HL5028 AF2008HL5029 AF2008HL5030 AF2008HL5041 N AF2008HL5041S AF201OHL5002L AF201OHL5002U AF201OHL5007E AF201OHL5007W Model No HYD-1300KIP HYD-1300KIP HYD-1300KIP HYD-1300KIP HYD-1300KIP HYD-1300KIP HYD-1300KIP HYD-1300KIP HYD-1300KIP HYD-1300KIP HYD-1300KIP HYD-1300KIP HYD-1300KIP HYD-1300KIP HYD-1 300KIP HYD-1300KIP AD5501 AD5501 AD5501 AD5501 AD5501 AD5501 AD5501 AD5501 AD5501 AD5501 AD5501 AD5501 AD5501 AD5501 Qc Level 2

2 2

2 2

2 2

2 2

2 2

2 2

2 2

2 2

2 2

2 2

2 2

2 2

2 2

2 2

2 Route I Location RCB SGA-N/E RCB SGB-N/E RCB SGC-N/E RCB SGD-N/E RCB SGA-N/W RCB SGB-N/W RCB SGC-NIW RCB SGD-N/W RCB SGA-S/W RCB SGB-SIVW RCB SGC-S/W RCB SGD-S/W RCB SGA-S/E RCB SGB-S/E RCB SGC-S/E RCB SGD-S/E RCB SGAD>52' RCB SGAD>52' RCB OMB >19' RCB SGAD>68' RCB SGAD>68' RCB SGAD>68' RCB SGAD>68' RCB OMB >19' RCB SGAD>68' RCB SGAD>68' RCB OMB >19' RCB OMB >19' RCB SGBC>52' RCB SGBC>52' Elev 58 58 58 58 58 58 58 58 58 58 58 58 58 58 58 58 19 19 19 19 19 19 19 19 19 19 19 19 19 19 Hang Dwg 400290-0001 OXX 400290-0001 OXX 400290-0001 OXX 400290-0001 OXX 400290-0001 OXX 400290-0001 OXX 400290-0001 OXX 400290-0001 OXX 400290-0001 OXX 400290-0001 OXX 400290-0001 OXX 400290-0001 OXX 400290-0001 OXX 400290-0001 OXX 400290-0001 OXX 400290-0001 OXX AF9006HL5003 AF9006HL5015 AF9006HL5018 AF9006HL5035 AF9006HL5035 AF9008HL5028 AF9008HL5029 AF9008HL5030 AF9008HL5041 AF9008HL5041 AF901OHL5002 AF901OHL5002 AF9010HL5007 AF9010HL5007 Iso Dwg 400290--00010XX 400290--0001OXX 400290--0001OXX 400290--0001OXX 400290--0001OXX 400290--0001OXX 400290--00010 XX 400290--0001OXX 400290--0001OXX 400290--0001OXX 400290--0001OXX 400290--0001OXX 400290--0001OXX 400290--0001OXX 400290--00010XX 400290--0001OXX 2C369PAF402-02 2C369PAF402-02 2C369PAF402-02 2C369PAF402-02 2C369PAF402-02 2C369PAF402-02 2C369PAF402-02 2C369PAF402-02 2C369PAF402-02 2C369PAF402-02 2C369PAF402-01 2C369PAF402-01 2C369PAF402-01 2C369PAF402-01 Pipe Dwg 0957-0100008WN 0957-0100008WN 0957-0100008WN 0957-0100008WN 0957-0100008WN 0957-0100008WN 0957-0100008WN 0957-0100008WN 0957-0100008WN 0957-0100008WN 0957-0100008WN 0957-0100008WN 0957-0100008WN 0957-0100008WN 0957-0100008WN 0957-0100008WN F00024 F00024 F00024 F00024 F00024 F00024 F00024 F00024 F00024 F00024 F00024 F00024 F00024 F00024

Unit-2 Snubber IST Listing Pages 2 of 13 Mdtpns Tagtpns /

Snubber AF2010HL5008L AF201OHL5008U AF2010HL5009 AF2010HL5017 AF201OHL5018 AF2010HL5020 AF2010HL5026 AF2010HL5035 AF2012HL5014E AF2012HL5014W AF2012HL5017 AF2012HL5018 AF2012HL5020 AF2012HL5024 AF2012HL5027 AF2012HL5038L AF2012HL5038U AF2054HL5004N AF2054HL5004S AF2061HL5001 AF2061 HL5002 AF2062HL5011 AF2062HL5012 AF2062HL5015 AF2063HL5002 AF2063HL5003 AF2063HL5005 AF2063HL5006 AF2064HL5004 AP2003HF5001 Model No AD5501 AD5501 AD1601 AD5501 AD1601 AD1601 AD1601 AD1601 AD1601 AD1601 AD5501 AD1601 AD1601 AD5501 AD5501 AD5501 AD5501 AD151 AD151 AD1601 AD1601 AD1601 AD1601 AD1601 AD1601 AD151 AD1601 AD1601 AD1601 AD41 Qc Level 2

2 2

2 2

2 2

2 2

2 2

2 2

2 2

2 2

3 3

2 2

2 2

2 2

2 2

2 2

2 Route / Location Elev RCB SGBC>68' 19 RCB SGBC>68' 19 RCB SGBC>68' 19 RCB SGBC>68' 19 RCB SGBC>68' 19 RCB SGBC>68' 19 RCB SGBC>19' 19 RCB SGBC>68' 19 RCB SGBC>68' 19 RCB SGBC>68' 19 RCB SGBC>68' 19 RCB SGBC>68' 19 RCB SGBC>68' 19 RCB OMB >19' 19 RCB OMB >19' 19 RCB SGBC>68' 19 RCB SGBC>68' 19 IVC D 34 IVC D 34 RCB SGAD>52' 19 RCB SGAD>68' 19 RCB SGAD>68' 19 RCB SGAD>68' 19 RCB SGAD>52' 19 RCB SGBC>68' 19 RCB SGBC>68' 19 RCB SGBC>68' 19 RCB SGBC>68' 19 RCB SGBC>52' 19 MAB RM 108C 29 Hang Dwg AF9010HL5008 AF9010HL5008 AF9010HL5009 AF901OHL5017 AF901OHL5018 AF9010HL5020 AF9010HL5026 AF9010HL5035 AF9012HL5014 AF9012HL5014 AF9012HL5017 AF9012HL5018 AF9012HL5020 AF9012HL5024 AF9012HL5027 AF9012HL5038 AF9012HL5038 AF9054HL5004 AF9054HL5004 AF9061HL5001 AF9061HL5002 AF9062HL5011 AF9062HL5012 AF9062HL5015 AF9063HL5002 AF9063HL5003 AF9063HL5005 AF9063HL5006 AF9064HL5004 AP2003HF5001 Iso Dwg Pipe Dwg 2C369PAF402-01 F00024 2C369PAF402-01 F00024 2C369PAF402-01 F00024 2C369PAF402-01 F00024 2C369PAF402-01 F00024 2C369PAF402-01 F00024 2C369PAF402-01 F00024 2C369PAF402-01 F00024 2C369PAF402-01 F00024 2C369PAF402-01 F00024 2C369PAF402-01 F00024 2C369PAF402-01 F00024 2C369PAF402-01 F00024 2C369PAF402-01 F00024 2C369PAF402-01 F00024 2C369PAF402-01 F00024 2C369PAF402-01 F00024 5G369PAF602-1 0 F00024 5G369PAF602-1 0 F00024 2C369PAF402-02 F00024 2C369PAF402-02 F00024 2C369PAF402-02 F00024 2C369PAF402-02 F00024 2C369PAF402-02 F00024 2C369PAF402-01 F00024 2C369PAF402-01 F00024 2C369PAF402-01 F00024 2C369PAF402-01 F00024 2C369PAF402-01 F00024 5M369PAP287-AO1 Z47501

Unit-2 Snubber IST Listing Pages 3 of 13 Mdtpns Tagtpns /

Snubber CC2105HL5004 CC2105HL5009 CC2109HL5001 N CC2109HL5001 S CC21 1 0HL5001 CC2136HL5002 CC2205HL5007L CC2205HL5007U CC2206HL5008 CC2209HL5002 CC2209HL5003 CC221OHL5001 CC2215SS0002 CC2220SS0002L CC2220SS0002U CC2309SS0002 CC2309SS0003L CC2309SS0003U CC231 1SS0001 CC2320HL5001 CC2425HL5016 CC2613SS0003 CV2002HL5002 CV2002HL5003 CV2002HL5004 CV2002HL5007 CV2002HL5008 CV2002HL5009 CV2002HL5010 CV2002HL5012 Model No AD5501 AD5501 AD501 AD501 AD 1601 AD501 AD501 AD501 AD501 AD1601 AD1601 AD1601 AD501 AD501 AD501 AD1601 AD1601 AD1601 AD1601 AD1601 AD151 AD151 AD71 AD71 AD71 AD151 AD71 AD151 AD151 AD71 Qc Level 3

3 3

3 3

7 3

3 3

3 3

3 3

3 3

3 3

3 3

3 3

7 2

2 2

2 2

2 2

2 Route I Location RCB RHR HX 2A RCB OMB >52' MAB RM 106A MAB RM 106A MAB RM 106A MAB RM 64 RCB OMB >52' RCB OMB >52' RCB OMB >52' MAB RM 216 MAB RM 216 MAB RM 106A RCB OMB >-11' MAB RM 64 MAB RM 64 MAB RM 216 MAB RM 216 MAB RM 216 MAB RM 216 MAB RM 216 FHB RM 208 RCB OMB >37' RCB SGBC>52' RCB SGBC>19' RCB SGBC>19' RCB SGBC>19' RCB SGBC>37' RCB SGBC>37' RCB SGBC>19' RCB SGBC>37' Elev 37 52 27 27 27 10 52 52 52 41 41 27

-11 10 10 41 41 41 41 41 30 37 19 19 19 19 19 19 19 19 Hang Dwg CC9105HL5004 CC9105HL5009 CC9109HL5001 CC9109HL5001 CC911 0HL5001 CC9136HL5002 CC9205HL5007 CC9205HL5007 CC9206HL5008 CC9209HL5002 CC9209HL5003 CC921OHL5001 CC9215SS02 CC9220SS0002 CC9220SS0002 CC9309SS0002 CC9309SS0003 CC9309SS0003 CC9311SS0001 CC9320HL5001 CC9425HL5016 CC9613SS0003 CV9002HL5002 CV9002HL5003 CV9002HL5004 CV9002HL5007 CV9002HL5008 CV9002HL5009 CV9002HL501 0 CV9002HL5012 Iso Dwg 4C369PCC407-08 4C369PCC407-08 5M362PCC207-07 5M362PCC207-07 5M362PCC207-07 5M362PCC207-07 5M362PCC207-07 5M362PCC207-07 4C369PCC407-10 5M369PCC207-11 5M369PCC207-11 5M369PCC207-22 3C369PCC407-16 5M369PCC207-11 5M369PCC207-11 5M362PCC207-01 5M362PCC207-01 5M362PCC207-01 5M369PCC207-08 5M362PCC207-01 5F369PCC507-01 5C369PCC407-03 4C369PCV417-04 4C369PCV417-04 4C369PCV417-04 4C369PCV417-04 4C369PCV417-04 4C369PCV417-04 4C369PCV417-04 4C369PCV417-04 Pipe Dwg F05017 F05017 F05017 F05017 F05017 F05017 F05018 F05018 F05018 F05018 F05018 F05018 F05018 F05018 F05018 F05019 F05019 F05019 F05019 F05019 F05020 F05021 F05005 F05005 F05005 F05005 F05005 F05005 F05005 F05005

Unit-2 Snubber IST Listing Pages 4 of 13 Mdtpns Tagtpns /

Snubber CV2002HL5019 CV2002HL5020 CV2002HL5021 CV2003HF5003 CV2003HL5003N CV2003HL5003S CV2004H F5001 CV2005HF5001 CV2006HL5037 CV201 1 HL5009 CV2086SS0002 CV2088H L5002 CV2116HL5018 CV2117HF5054 CV2117HL5005 CV2117SS0006 CV2121HS5007 CV2121 HS5009 CV2121HS5010 FC2009SS0001 FC201 1 HL5001 FC2012HL5002 FW2012HL5002E FW2012HL5002W FW2012HL5003 FW2012HL5005L FW2012HL5005U FW2012HL5011 FW2012HL5016 FW2014HL5001E Model No AD151 AD151 AD501 AD151 AD151 AD151 AD41 AD41 AD 1601 AD71 AD71 AD41 AD71 AD41 AD501 AD1601 AD41 AD151 AD151 AD41 AD1601 AD501 AD5501 AD5501 AD12501 AD5501 AD5501 AD5501 AD12501 AD5501 Qc Level 2

2 2

2 2

2 2

2 2

2 2

2 2

2 2

2 1

1 1

3 2

3 2

2 2

2 2

2 2

2 Route I Location Elev RCB SGBC>19' RCB SGBC>19' RCB SGBC>19' RCB RGN HX RCB RGN HX RCB RGN HX RCB RGN HX RCB RGN HX MAB RM 108C MAB RM 49 MAB RM 110 MAB RM 31 MAB RM 108C RCB PZR RCB SGBC>37' RCB SGBC>37' RCB PZR RCB PZR RCB PZR FHB RM 110 FHB RM 110 FHB RM 110 RCB SGAD>37' RCB SGAD>37' RCB SGAD>37' RCB OMB >37' RCB OMB >37' RCB SGAD>19' RCB SGAD>37' RCB SGBC>37' 19 19 19 37 37 37 37 37 29 10 29 10 29 37 19 19 37 37 37 21 21 21 19 19 19 37 37 19 19 19 Hang Dwg CV9002HL5019 CV9002HL5020 CV9002HL5021 CV2003HF5003 CV2003HL5003 CV2003HL5003 CV2004HF5001 CV2005HF5001 CV9006HL5037 CV901 1 HL5009 CV9086SS0002 CV9088HL5002 CV9116HL5018 CV2117HF5054 CV9117HL5005 CV9117SS0006 CV9121HS5007 CV9121 HS5009 CV9121 HS5010 FC9009SS0001 FC901 1 HL5001 FC9012HL5002 FW9012HL5002 FW9012HL5002 FW9012HL5003 FW9012HL5005 FW9012HL5005 FW9012HL5011 FW2012HL5016 FW9014HL5001 Iso Dwg Pipe Dwg 4C369PCV417-04 F05005 4C369PCV417-04 F05005 4C369PCV417-04 F05005 5C369PCV417-A09 F05005 4C369PCV417-04 F05005 4C369PCV417-04 F05005 5C369PCV417-A09 F05005 5C369PCV417-A09 F05005 4M369PCV217-04 F05005 4M369PCV217-04 F05006 2M369PCV217-05 F05006 4M369PCV217-04 F05006 2M369PCV217-20 F05007 4C369PCV417-A02 F05005 4C369PCV417-02 F05005 4C369PCV417-02 F05005 4C369PCV417-A02 F05005 4C369PCV417-A02 F05005 4C369PCV417-A02 F05005 4F369PFC530-03 F05028 4F369PFC530-02 F05028 4F369PFC530-02 F05028 2C369PFW433-01 F00062 2C369PFW433-01 F00062 2C369PFW433-01 F00062 2C369PFW433-01 F00062 2C369PFW433-01 F00062 2C369PFW433-01 F00062 2C369PFW433-01 F00062 2C369PFW433-01 F00062

Unit-2 Snubber IST Listing Pages 5 of 13 Mdtpns Tagtpns /

Snubber FW2014HL5001W FW2014HL5002 FW2014HL5003L FW2014H L5003U FW2014HL5009 FW2014HL5012 FW2016HL5003 FW2016HL5004 FW2016HL5006 FW2016HL5007 FW2016HL5008 FW2016HL5009 FW2016HL5010 FW2016SH0001 FW2016SS0006 FW201 8HL5003 FW2018HL5004 FW201 8HL5006L FW201 8HL5006U FW2018HL5007N FW201 8HL5007S FW201 8HL5008 FW201 8HL5009 FW2018SS0001 FW2018SS0006 FW2018SS0007 FW2029HL5002E FW2029H L5002W FW2029H L5003 FW2030H L5002E Model No AD5501 AD12501 AD5501 AD5501 AD12501 AD5501 AD5501 AD5501 AD5501 AD5501 AD5501 AD12501 AD5501 AD5501 AD5501 AD5501 AD5501 AD5501 AD5501 AD5501 AD5501 AD12501 AD12501 AD5501 AD5501 AD12501 AD1601 AD1601 AD1601 AD 1601 Qc Level 2

2 2

2 2

2 2

2 2

2 2

2 2

2 2

2 2

2 2

2 1

2 2

2 2

2 2

2 2

2 Route I Location Elev RCB SGBC>37' RCB SGBC>37' RCB RGN HX RCB RGN HX RCB SGBC>37' RCB SGBC>19' RCB RGN HX RCB SGBC>19' RCB SGBC>52' RCB SGBC>19' RCB RGN HX RCB SGBC>37' RCB SGBC>37' RCB SGBC>19" RCB SGBC>52' RCB OMB >37' RCB SGAD>19' RCB OMB >37' RCB OMB >37' RCB SGAD>37' RCB SGAD>37' RCB SGAD>37' RCB SGAD>37' RCB SGAD>19' RCB SGAD>52' RCB SGAD>37' IVC A IVC A IVC A IVC B 19 19 37 37 19 19 37 19 19 19 37 19 19 19 19 37 19 37 37 19 19 19 19 19 19 19 44 44 44 44 Hang Dwg FW9014HL5001 FW9014HL5002 FW9014HL5003 FW9014HL5003 FW9014HL5009 FW9014HL5012 FW9016HL5003 FW9016HL5004 FW9016HL5006 FW9016HL5007 FW9016HL5008 FW9016HL5009 FW9016HL5010 FW9016SH0001 FW9016SS0006 FW9018HL5003 FW9018HL5004 FW9018HL5006 FW9018HL5006 FW9018HL5007 FW9018HL5007 FW9018HL5008 FW9018HL5009 FW9018SS0001 FW9018SS0006 FW9018SS0007 FW9029HL5002 FW9029HL5002 FW9029HL5003 FW9030H L5002 Iso Dwg 2C369PFW433-01 2C369PFW433-01 2C369PFW433-01 2C369PFW433-01 2C369PFW433-01 2C369PFW433-01 2C369PFW433-11 2C369PFW433-01 2C369PFW433-01 2C369PFW433-01 2C369PFW433-01 2C369PFW433-01 2C369PFW433-01 2C369PFW433-01 2C369PFW433-01 2C369PFW433-01 2C369PFW433-01 2C369PFW433-01 2C369PFW433-01 2C369PFW433-01 2C369PFW433-01 2C369PFW433-01 2C369PFW433-01 2C369PFW433-01 2C369PFW433-01 2C369PFW433-01 2G369PFW633-02 2G369PFW633-02 2G369PFW633-02 2G369PFW633-03 Pipe Dwg F00062 F00062 F00062 F00062 F00062 F00062 F00062 F00062 F00062 F00062 F00062 F00062 F00062 F00062 F00062 F00062 F00062 F00062 F00062 F00062 F00062 F00062 F00062 F00062 F00062 F00062 F00062 F00062 F00062 F00062

Unit-2 Snubber IST Listing Pages 6 of 13 Mdtpns Tagtpns I Snubber FW2030H L5002W FW2030H L5003 FW2031 H L5002E FW2031 H L5002W FW2031 H L5003 FW2032H L5002E FW2032H L5002W FW2032H L5003 FW2117HL5001 FW2117HL5003 FW2117HL5004 FW2119HL5001 FW2119HL5003 FW2119HL5004 FW2121 HL5001 FW2121 HL5003 FW2121 H L5004 FW2123HL5001 FW2123HL5003 FW2123HL5004 MD2147HF5002 MD2148HF5002 MD2149HF5002 MD2150HF5002 MS2001 HL5004 MS2001 HL5007 MS2001 HL501 OL MS2001 HL501 OU MS2001HL5011E MS2001 HL501 1W Model No AD 1601 AD 1601 AD1601 AD1601 AD1601 AD1601 AD1601 AD1601 AD41 AD41 AD41 AD41 AD41 AD41 AD41 AD41 AD41 AD41 AD41 AD41 AD71 AD71 AD71 AD71 AD5501 AD12501 AD1601 AD1601 AD5501 AD5501 Qc Level 2

2 2

2 2

2 2

2 2

2 2

2 2

2 2

2 2

2 2

2 7

7 7

7 2

2 2

2 2

2 Route / Location Elev IVC B 44 IVC B 44 IVC C 44 IVC C 44 IVC C 44 IVC D 44 IVC D 44 IVC D 44 IVC C 34 IVC C 34 IVC C 44 IVC B 34 IVC B 34 IVC B 44 IVC A 34 IVC A 34 IVC A 34 IVC D 34 IVC D 34 IVC D 34 IVC A 44 IVC B 44 IVC C 44 IVC D 44 RCB OMB >68' 68 RCB SGAD>68' 19 IVC A 51 IVC A 51 IVC A 51 IVC A 51 Hang Dwg FW9030H L5002 FW9030H L5003 FW9031 H L5002 FW9031 H L5002 FW9031 H L5003 FW9032H L5002 FW9032H L5002 FW9032H L5003 FW9117HL5001 FW9117HL5003 FW9117HL5004 FW9119HL5001 FW9119HL5003 FW9119HL5004 FW9121 HL5001 FW9121 HL5003 FW9121 HL5004 FW9123HL5001 FW9123HL5003 FW9123HL5004 MD2147HF5002 MD2148HF5002 MD2149HF5002 MD2150HF5002 MS9001HL5004 MS9001HL5007 MS9001HL5010 MS9001HL5010 MS9001 HL5011 MS9001HL5011 Iso Dwg Pipe Dwg 2G369PFW633-03 F00062 2G369PFW633-03 F00062 2G369PFW633-04 F00062 2G369PFW633-04 F00062 2G369PFW633-04 F00062 2G369PFW633-01 F00062 2G369PFW633-01 F00062 2G369PFW633-01 F00062 2G369PFW633-05 F00063 2G369PFW633-05 F00063 2G369PFW633-05 F00063 2G369PFW633-05 F00063 2G369PFW633-05 F00063 2G369PFW633-05 F00063 2G369PFW633-05 F00063 2G369PFW633-05 F00063 2G369PFW633-05 F00063 2G369PFW633-05 F00063 2G369PFW633-05 F00063 2G369PFW633-05 F00063 9G369PMD645-AO1 F00055 9G369PMD645-AO1 F00055 9G369PMD645-AO1 F00055 9G369PMD645-AO1 F00055 2C369PMS446-01 F00016 2C369PMS446-01 F00016 2G369PMS646-06 F00016 2G369PMS646-06 F00016 2G369PMS646-06 F00016 2G369PMS646-06 F00016

Unit-2 Snubber IST Listing Pages 7 of 13 Mdtpns Tagtpns /

Snubber MS2001 HL5012L MS2001 HL5012U MS2001HL5015 MS2002HL5006 MS2002HL5007 MS2002HL5010L MS2002HL501OU MS2002HL501 1 E MS2002HL501 1W MS2002HL5012L MS2002HL5012U MS2002HL5015 MS2002HL5016 MS2003HL5004 MS2003HL5012 MS2003HL5013 MS2003HL5014 MS2003HL5015L MS2003HL5015U MS2003HL5016E MS2003HL5016W MS2003HL5017L MS2003HL5017U MS2004HL5007 MS2004HL5012 MS2004HL5013 MS2004HL5014 MS2004HL5015L MS2004HL5015U MS2004HL5016E Model No AD1601 AD1601 AD5501 AD5501 AD12501 AD 1601 AD1601 AD5501 AD5501 AD1601 AD1601 AD5501 AD5501 AD5501 AD12501 AD5501 AD5501 AD1601 AD1601 AD5501 AD5501 AD1601 AD1601 AD5501 AD12501 AD12501 AD12501 AD1601 AD1601 AD5501 Qc Level 2

2 2

2 2

2 2

2 2

2 2

2 2

2 2

2 2

2 2

2 2

2 2

2 2

2 2

2 2

2 Route / Location Elev IVC A 51 IVC A 51 RCB SGAD>83' 19 RCB OMB >68' 68 RCB SGBC>68' 19 IVC B 51 IVC B 51 IVC B 51 IVC B 51 IVC B 51 IVC B 51 RCB SGBC>83' 19 RCB SGBC>83' 19 RCB OMB >68' 68

  • RCB SGBC>68' 19 RCB SGBC>83' 19 RCB SGBC>83' 19 IVC C 51 IVC C 51 IVC C 51 IVC C 51 IVC C 51 IVC C 51 RCB OMB >68' 68 RCB SGAD>68' 19 RCB PZR 37 RCB SGAD>83' 19 IVC D 51 IVC D 51 IVC D 51 Hang Dwg MS9001 HL5012 MS9001 HL5012 MS9001 HL5015 MS9002HL5006 MS9002HL5007 MS9002HL5010 MS9002HL5010 MS9002HL5011 MS9002HL5011 MS9002HL5012 MS9002HL5012 MS9002HL5015 MS9002HL5016 MS9003HL5004 MS9003HL5012 MS9003HL5013 MS9003HL5014 MS9003HL5015 MS9003HL5015 MS9003HL5016 MS9003HL5016 MS9003HL5017 MS9003HL5017 MS9004HL5007 MS9004HL5012 MS9004HL5013 MS9004HL5014 MS9004HL5015 MS9004HL5015 MS9004HL5016 Iso Dwg 2G369PMS646-06 2G369PMS646-06 2C369PMS446-01 2C369PMS466-02 2C369PMS446-02 2G369PMS646-07 2G369PMS646-07 2G369PMS646-07 2G369PMS646-07 2G369PMS646-07 2G369PMS646-07 2C369PMS446-02 2C369PMS446-02 2C369PMS446-03 2C369PMS446-03 2C369PMS446-03 2C369PMS446-03 2G369PMS646-08 2G369PMS646-08 2G369PMS646-08 2G369PMS646-08 2G369PMS646-08 2G369PMS646-08 2C369PMS446-04 2C369PMS446-04 2C369PMS446-04 2C369PMS446-04 2G369PMS646-09 2G369PMS646-09 2G369PMS646-09 Pipe Dwg F00016 F00016 F00016 F00016 F00016 F00016 F00016 F00016 F00016 F00016 F00016 F00016 F00016 F00016 F00016 F00016 F00016 F00016 F00016 F00016 F00016 F00016 F00016 F00016 F00016 F00016 F00016 F00016 F00016 F00016

Unit-2 Snubber IST Listing Pages 8 of 13 Mdtpns Tagtpns /

Snubber MS2004HL5016W MS2004HL5017L MS2004HL5017U MS2005SS0001 N MS2005SS0001 S MS2005SS0002E MS2005SS0002W MS2006SS0001 N MS2006SS0001S MS2006SS0002E MS2006SS0002W MS2007SS0002E MS2007SS0002W MS2008HL5001 MS2008SS0001 E MS2008SS0001W MS2013HL5002E MS2013HL5002W MS2013HL5003 MS2013HL5004 MS2013SS0002E MS2013SS0002W MS2051 HL5009 PS2020HF5002 RC2000SS0001 RC2003HL5006 RC2003HL5009 RC2014HL5001 RC2014HL5003E RC2014HL5003W Model No AD5501 AD 1601 AD1601 AD5501 AD5501 AD5501 AD5501 AD5501 AD5501 AD5501 AD5501 AD5501 AD5501 AD5501 AD5501 AD5501 AD5501 AD5501 AD5501 AD5501 AD5501 AD5501 AD71 AD41 AD151 AD501 AD501 AD5501 AD5501 AD5501 Qc Level 2

2 2

7 7

7 7

7 7

7 7

7 7

7 7

7 7

7 7

7 7

7 3

7 1

1 7

7 7

Route / Location Elev IVC D 51 IVC D 51 IVC D 51 TGB B 55 TGB B 55 TGB B 29 TGB B 29 TGB B 55 TGB B 55 TGB B 29 TGB B 29 TGB B 29 TGB B 29 TGB B 55 TGB B 29 TGB B 29 TGB B 55 TGB B 55 TGB B 55 TGB B 55 TGB B 55 TGB B 55 IVC D 10 MAB RM 108C 29 RCB PZR 37 RCB PZR 37 RCB PZR 37 RCB PZR 37 RCB PZR 37 RCB PZR 37 Hang Dwg MS9004HL5016 MS9004HL5017 MS9004HL5017 MS9005SS0001 MS9005SS0001 MS9005SS0002 MS9005SS0002 MS9006SS0001 MS9006SS0001 MS9006SS0002 MS9006SS0002 MS9007SS0002 MS9007SS0002 MS9008HL5001 MS9008SS0001 MS9008SS0001 MS9013HL5002 MS9013HL5002 MS9013HL5003 MS9013HL5004 MS9013SS0002 MS9013SS0002 MS9051 HL5009 PS2020HF5002 RC2000SS0001 RC9003HL5006 RC9003HL5009 RC9014HL5001 RC9014HL5003 RC9014HL5003 Iso Dwg 2G369PMS646-09 2G369PMS646-09 2G369PMS646-09 7G369PMS846-05 7G369PMS846-05 7G369PMS846-05 7G369PMS846-05 7G369PMS846-06 7G369PMS846-06 7G369PMS846-06 7G369PMS846-06 7G369PMS846-06 7G369PMS846-06 7G369PMS846-05 7G369PMS846-05 7G369PMS846-05 7G369PMS846-08 7G369PMS846-08 7G3G9PMS846-05 7G369PMS846-05 7G369PMS846-09 7G369PMS846-09 4G369PMS646-05 5M369PPS285-AO1 4C369PRC457-07 1C369PRC457-06 1C369PRC457-06 7C369PRC457-02 7C769PRC457-02 7C369PRC457-02 Pipe Dwg F00016 F00016 F00016 F00016 F00016 F00016 F00016 F00016 F00016 F00016 F00016 F00016 F00016 F00016 F00016 F00016 F00016 F00016 F00016 F00016 F00016 F00016 F00024 Z00045 F05003 F05003 F05003 F05004 F05004 F05004

Unit-2 Snubber IST Listing Pages 9 of 13 Mdtpns Tagtpns /

Snubber RC2014HL5005N RC2014HL5005S RC2014HL5006L RC2014HL5006U RC2014HL5009 RC2014HL5012N RC2014HL5012S RC2014HL5013 RC2014HL5015 RC2014HL5019N RC2014HL5019S RC2014HL5026 RC2014HL5028 RC2112HL5002 RC2123HL5013 RC2125HL5001 RC2125HL5008 RC2221 HL5001 RC2221 HL5003 RC2221 HL5004 RC2221 HL5005 RC2221 HL5006 RC2221 HL5007 RC2320HL5002 RC2320HL5004 RC2422HL5019 RH21 01 HL5001 RH21 01 HL5002 RH2101 H L5003 RH2101 H L5006 Model No AD5501 AD5501 AD5501 AD5501 AD501 AD5501 AD5501 AD1601 AD1601 AD5501 AD5501 AD501 AD1601 AD5501 AD501 AD5501 AD1601 AD1601 AD5501 AD5501 AD5501 AD5501 AD5501 AD1601 AD501 AD501 AD1601 AD1601 AD1601 AD5501 Qc Level 7

7 7

7 7

7 7

7 7

7 7

7 71 1

1 1

1 1

1 1

1 1

1 1

1 1

1 1

Route I Location Elev RCB PZR RCB PZR RCB PZR RCB PZR RCB PZR RCB PZR RCB PZR RCB PZR RCB PZR RCB PZR RCB PZR RCB PZR RCB PZR RCB SGAD>19' RCB PZR RCB IMB >-11' RCB IMB >-11' RCB IMB >-11' RCB IMB >-11' RCB SGBC>19' RCB SGBC>19' RCB IMB >-11' RCB IMB >-11' RCB SGBC>19' RCB SGBC>19' RCB SGAD>52' RCB VLV RM RCB VLV RM RCB VLV RM RCB SGAD>19' 37 37 37 37 37 37 37 37 37 19 19 19 19 19 37

-11

-11

-11

-11 19 19

-11

-11 19 19 19

-2

-2 19 19 Hang Dwg RC9014HL5005 RC9014HL5005 RC9014HL5006 RC9014HL5006 RC9014HL5009 RC9014HL5012 RC9014HL5012 RC9014HL5013 RC9014HL5015 RC9014HL5019 RC9014HL5019 RC9014HL5026 RC9014HL5028 RC9112HL5002 RC9123HL5013 RC9125HL5001 RC9125HL5008 RC9221 HL5001 RC9221 HL5003 RC9221 HL5004 RC9221 HL5005 RC9221HL5006 RC9221 HL5007 RC9320HL5002 RC9320HL5004 RC9422HL5019 RH9101 H L5001 RH9101 HL5002 RH9101 HL5003 RH9101 HL5006 Iso Dwg 7C369PRC457-02 7C369PRC457-02 7C369PRC457-02 7C369PRC457-02 7C369PRC457-02 7C369PRC457-02 7C369PRC457-02 7C369PRC457-02 7C369PRC457-02 7C369PRC457-02 7C369PRC457-02 7C369PRC457-02 7C369PRC457-02 4C369PRC457-09 4C369PRC457-07 4C369PRC457-10 4C369PRC457-10 4C369PRC457-10 4C369PRC457-10 4C369PRC457-10 4C369PRC457-10 4C369PRC457-10 4C369PRC457-10 4C369PRC457-04 4C369PRC457-04 1 C369PRC457-06 4C369PRH459-04 4C369PRH459-04 4C369PRH459-04 4C369PRC459-04 Pipe Dwg F05004 F05004 F05004 F05004 F05004 F05004 F05004 F05004 F05004 F05004 F05004 F05004 F05004 F05001 F05001 F05001 F05001 F05001 F05001 F05001 F05001 F05001 F05001 F05001 F05001 F05001 F20000 F20000 F20000 F20000

Unit-2 Snubber IST Listing Pages 10 of 13 Mdtpns Tagtpns/

Snubber RH21 01 HL5009 RH21 10HL5002 RH2201 HL5001 RH2201 HL5006 RH2202SS0002 RH2203HL5001 RH2204HL5001 RH221 1 HL5002L RH221 1 HL5002U RH2303HL5007 RH2303HL5009 RH2306SS0001 RH2312HL5002 RH2313HL5003L RH2313HL5003U SB2101HL5007 SB2101HL5012 SB2101HL5017 SB2101HL5019 SB2101HL5020 SB2101HL5022 SB2104HL5001 SB2104HL5002 SB2104HL5006 SB2105HL5001 SB2107HF5001 SB2201HL5004 SB2201HL5010 SB2201HL5013 SB2201HL5017 Model No AD1601 AD501 AD1601 AD5501 AD1601 AD501 AD501 AD501 AD501 AD501 AD501 AD501 AD501 AD501 AD501 AD1601 AD501 AD1601 AD501 AD501 AD501 AD501 AD501 AD501 AD71 AD41 AD1601 AD1601 AD501 AD501 Qc Level 1

2 1

1 2

2 2

2 2

2 2

2 2

2 2

2 2

2 2

2 2

7 7

7 7

2 2

2 2

2 Route I Location RCB SGAD>19' RCB SGAD>19' RCB VLV RM RCB VLV RM RCB VLV RM RCB VLV RM RCB VLV RM RCB SGBC>19' RCB SGBC>19' RCB VLV RM RCB VLV RM RCB VLV RM RCB VLV RM RCB SGBC>19' RCB SGBC>19' RCB OMB >19' RCB SGAD>19' RCB OMB >19' IVC A IVC A IVC A IVC A IVC A IVC A IVC A IVC A RCB OMB >19' RCB OMB >19' RCB SGBC>19' IVC B Elev 19 19

-2

-2

-2 19 19 19 19 19

-2

-2 19 19 19 19 19 19 10 10 10 10 10 10 10 10 19 19 19 10 Hang Dwg RH9101 HL5009 RH91 10HL5002 RH9201 HL5001 RH9201HL5006 RH9202SS0002 RH9203HL5001 RH9204HL5001 RH921 1 HL5002 RH921 1 HL5002 RH9303HL5007 RH9303HL5009 RH9306SS0001 RH9312HL5002 RH9313HL5003 RH9313HL5003 SB9101 HL5007 SB9101 HL5012 SB9101 HL5017 SB9101HL5019 SB9101 HL5020 SB9101 H L5022 SB9104HL5001 SB9104HL5002 SB9104HL5006 SB9105HL5001 SB2107HF5001 SB9201 HL5004 SB9201 HL5010 SB9201 HL5013 SB9201 HL5017 Iso Dwg Pipe Dwg 4C369PRH459-04 F20000 4C369PRH459-03 F20000 4C369PRH459-07 F20000 4C369PRH459-07 F20000 4C369PRH459-07 F20000 2C369PRH459-02 F20000 2C369PRH459-02 F20000 4C369PRH459-07 F20000 4C369PRH459-07 F20000 2C369PRH459-05 F20000 2C369PRH459-05 F20000 4C369PRH459-06 F20000 4C369PRH459-01 F20000 4C369PRH459-06 F20000 4C369PRH459-06 F20000 2C369PSB468-02 F20001 2C369PSB468-02 F20001 2C369PSB468-02 F20001 5G369PSB668-03 F20001 5G369PSB668-03 F20001 5G369PSB668-03 F20001 5G369PSB668-03 F20001 5G369PSB668-03 F20001 5G369PSB668-03 F20001 5G369PSB668-03 F20001 7G369PSB668-AO1 F20001 2C369PSB468-02 F20001 2C369PSB468-02 F20001 2C369PSB468-02 F20001 5G369PSB668-05 F20001

Unit-2 Snubber IST Listing Pages 11 of 13 Mdtpns Tagtpns /

Snubber S B2201HL5018 SB2201HL5020 SB2202HF5002 SB2204HL5001 SB2204HL5002 SB2205HL5003 SB2207HF5001 SB2250HF5003 SB2274HL5002L SB2274HL5002U SB2301HL5003L SB2301 HL5003U SB2301HL5011L SB2301HL5011U SB2301HL5012N SB2301HL5012S SB2301HL5018 SB2301 HL5020 SB2301HL5021 SB2302HF5003 SB2303HF5005 SB2304HL5001 SB2304HL5002 SB2304HL5006 SB2350HF5016 SB2401 HL5003 SB2401HL5011 SB2401HL5012 SB2401 HL5016L SB2401HL5016U Model No AD501 AD501 AD41 AD501 AD501 AD151 AD41 AD41 AD151 AD151 AD501 AD501 AD501 AD501 AD151 AD151 AD501 AD501 AD501 AD151 AD151 AD501 AD501 AD501 AD41 AD1601 AD1601 AD501 AD151 AD151 Qc Level 2

2 2

7 7

7 7

2 7

7 2

2 2

2 2

2 2

2 2

2 2

7 7

7 2

2 2

2 2

2 Route I Location IVC B IVC B RCB SGBC>19' IVC B IVC B IVC B IVC B RCB SGBC>19' IVC B IVC B RCB OMB >19' RCB OMB >19' RCB SGBC>19' RCB SGBC>19' RCB SGBC>19' RCB SGBC>19' IVC C IVC C IVC C RCB SGBC>19' RCB SGBC>37' IVC C IVC C IVC C RCB SGBC>19' RCB OMB >19' RCB OMB >19' RCB SGAD>19' RCB SGAD>19' RCB SGAD>19' Elev 10 10 19 10 10 10 10 19 10 10 19 19 19 19 19 19 10 10 10 19 19 10 10 10 19 19 19 19 19 19 Hang Dwg SB9201 HL5018 SB9201 HL5020 SB2202HF5002 SB9204H L5001 SB9204HL5002 SB9205HL5003 SB2207HF5001 SB2250HF5003 SB9274HL5002 SB9274HL5002 SB9301 HL5003 SB9301 HL5003 SB9301 HL5011 SB9301HL5011 SB9301 HL5012 SB9301 HL5012 SB9301 HL5018 SB9301HL5020 SB9301 HL5021 SB2302HF5003 SB2303HF5005 SB9304HL5001 SB9304HL5002 SB9304HL5006 SB2350HF5016 SB9401 HL5003 SB9401 HL5011 SB9401 HL5012 SB9401 HL5016 SB9401 HL5016 Iso Dwg Pipe Dwg 5G369PSB668-05 F20001 5G369PSB668-05 F20001 2C362PSB468-A05 F20001 5G369PSB668-05 F20001 5G369PSB668-05 F20001 5G369PSB668-05 F20001 7G369PSB668-AO1 F20001 2C362PSB468-A05 F20001 5G369PSB668-05 F20002 5G369PSB668-05 F20002 2C369PSB468-02 F20001 2C369PSB468-02 F20001 2C369PSB468-02 F20001 2C369PSB468-02 F20001 2C369PSB468-02 F20001 2C369PSB468-02 F20001 5G369PSB668-07 F20001 5G369PSB668-07 F20001 5G369PSB668-07 F20001 2C369PSB468-A04 F20001 2C369PSB468-A04 F20001 5G369PSB668-07 F20001 5G369PSB668-07 F20001 5G369PSB668-07 F20001 2C362PSB468-A05 F20001 2C369PSB468-02 F20001 2C369PSB468-02 F20001 2C369PSB468-02 F20001 2C369PSB468-02 F20001 2C369PSB468-02 F20001

Unit-2 Snubber IST Listing Pages 12 of 13 Mdtpns Tagtpns /

Snubber SB2401HL5019 SB2401HL5020 SB2401HL5022 SB2401HL5023 SB2402HF5002 SB2402HF5004 SB2403HF5002 SB2404HL5001 SB2404HL5002 SB2406HL5007 SB2407HF5001 SB2474HL5002 S12101 SS0008L S12101 SS0008U S12107HL5001 N S12107HL5001S S12107SS0061 S12108HL5001 S12108HL5003 S12201 HL501 OL S12201 HL501 OU S12205HL5022 S12206HL5008 S12206HL5012 S12207SS0001 S12208HL5005 S12217HL5009 S12301 SS0005L S12301 SS0005U S12306HL5012 Model No AD501 AD501 AD501 AD501 AD71 AD71 AD151 AD501 AD501 AD41 AD41 AD501 AD501 AD501 AD501 AD501 AD501 AD 1601 AD501 AD501 AD501 AD501 AD151 AD501 AD501 AD1601 AD1601 AD501 AD501 AD151 Qc Level 2

2 2

2 2

2 2

7 7

7 7

7 2

2 2

2 2

1 1

2 2

2 2

2 2

1 2

2 2

2 Route I Location RCB SGAD>19' IVC D IVC D IVC D RCB SGAD>37' RCB SGAD>37' RCB SGAD>19' IVC D IVC D IVC D IVC D IVC D FHB HHSI A FHB HHSI A RCB OMB >19' RCB OMB >19' RCB OMB >19' RCB SGAD>19' RCB SGAD>19' FHB HHSI B FHB HHSI B RCB IMB >-11' RCB IMB >-11' RCB IMB >-11' RCB OMB >19' RCB SGBC>19' RCB OMB >-11' FHB HHSI C FHB HHSI C FHB HHSI C Elev 19 10 10 10 19 19 19 10 10 10 10 10

-29

-29 19 19 19 19 19

-29

-29

-11

-11

-11 19 19

-2

-29

-29

-29 Hang Dwg SB9401 HL5019 SB9401 HL5020 SB9401 HL5022 SB9401HL5023 SB2402HF5002 SB2402HF5004 SB2403HF5002 SB9404HL5001 SB9404HL5002 SB9406HL5007 SB2407HF5001 SB9474HL5002 SI9101SS0008 SI9101SS0008 S19107HL5001 S19107HL5001 S19107SS0061 S19108HL5001 S19108HL5003 S19201 HL5010 S19201 HL5010 S19205HL5022 S19206HL5008 S19206HL5012 S19207SS0001 S19208HL5005 S19217HL5009 S19301SS0005 S19301SS0005 S19306HL5012 Iso Dwg Pipe Dwg 2C369PSB468-02 F20001 5G369PSB668-01 F20001 5G369PSB668-01 F20001 5G369PSB668-01 F20001 2C369PSB468-A04 F20001 2C369PSB468-A04 F20001 2C368PSB468-A04 F20001 5G369PSB668-01 F20001 5G369PSB668-01 F20001 5G369PSB668-01 F20001 7G369PSB668-AO1 F20001 5G369PSB668-01 F20002 2F369PS1572-03 F05013 2F369PS1572-03 F05013 4C369PS1472-01 F05013 4C369PS1472-01 F05013 4C369PS1472-01 F05013 4C369PS1472-01 F05013 4C369PS1472-01 F05013 2F369PS1572-04 F05014 2F369PS1572-04 F05014 2C369PS1472-02 F05014 4C369PS1472-05 F05014 4C369PS1472-05 F05014 4C369PS1472-05 F05014 4C369PS1472-05 F05014 5C369PS1472-03 F05016 2F369PS1572-06 F05015 2F369PS1572-06 F05015 2F369PS1572-05 F05015

Unit-2 Snubber IST Listing Pages 13 of 13 Mdtpns Tagtpns /

Snubber S12308HL5001 S12314HL5007 S12315HL5003 S12315HL5004 S12326HL5001 S12327HL5001 WL2019HF5001 Model No AD501 AD5501 AD12501 AD5501 AD501 AD1601 AD71 Qc Level 1

2 1

1 2

2 7

Route / Location Elev RCB IMB >-11'

-11 RCB IMB >-11'

-11 RCB SGBC>19' 19 RCB SGBC>19' 19 RCB SGBC>19' 19 RCB SGBC>19' 19 RCB IMB >-11'

-11 Hang Dwg S19308HL5001 S19314HL5007 S19315HL5003 S19315HL5004 S19326HL5001 S19327HL5001 WL2019HF5001 Iso Dwg Pipe Dwg 4C369PS1472-07 F05015 5C369PS1472-03 F05016 5C369PS1472-03 F05016 5C369PS1472-03 F05016 4C369PS1472-07 F05015 4C369PS1472-07 F05015 7G369PWL477-A03 F05022

ATTACHMENT 3 Snubber Code Cases - Information Only Revision 0

ASMEOM CODE-2004 CODE CASE OMN-13 (04)

Requirements for Extending Snubber Inservice Visual Examination Interval at LWR Power Plants This Code Case shall expire on February 12, 2007 unless previously annulled or reaffirmed.

inquint: With the low rate of problem identificatior through the visual examination process, can the visua.

examination interval allowed in Table ISTD 6__2-1 oi the OM Code, Subsection ISTD, 1995 Edition 199k Addenda be extended?

Reply: Yes, provided that the following additiona service life monitoring requirements are met.

Applicability: ASMVE OM Code 1995 Edition with 199(

Addenda and later editions and addenda.

I APPLICABILITY This Code Case establishes specific requirements tim must be met in order to allow extension of the visua examination interval beyond the maximum interva allowed in Table [STD 6.5.2-i for mechanical anc hydraulic snubbers. Paragraphs referenced in this Codc Case denote the 1995 Edition and 1996 Addenda. P correlation Table 1 is provided for 1998 Edition.

2 GENERAL REQUIREMENTS The following requirements shall be implemented ir order to extend rthe visual examination interval bevonc the maximum interval allowed in Tabie 15STD 6.5.2-1.

(a) These requirements are in addition to the servici life monitoring requirements in ISTD 8.

(b) The requirements of this Code Case shall be imple mented after the requirements of ISTD 6.5.1., [STE 6.5.2(a), TSTD 6.5.2(b), and iSTD 6.5.2(c) have been satis fled and the previous examination per Table LSTD 6.5.2.

1 was performed at a maximum interval of two fue cycles.

(C) Demonstrate that the requirements of oaras. 3.1 3.2, 3.3, 3.4. 3.5, and 3.6 of this Code Case have beer met for one interval prior to extending the examinatior interval.

2.1. Service Life Evaluations The data and information gathered under this Codt Case shall be utilized to reevaluate service life a:

described in ISTD 8.

2.2 Testing for This Code Case Snubbers tested soecificailv for this Code Case shal be dispositioned per ISTD 8.5.

co SIn AsE£ le--. ahj

,'rooP a t1 V irS 1

US3 r,L osw willi ASME NO 'e pr-,.,ouobk or n w*00 lorr.e ed wihoro b s, iron

-HS LCorrelation Table 1995 Edition and 1996 Addenda 1998 Edition I57T 1.13 ISTD-1750 ISTD 6 ISTD-4 200 L

157D 6.1. 6.2, 6.3, 6.4 ISTD-4210, 4220, 4230, 4240 1ST 6.5.1 iSTD-4251 ISM 6.3.2(a)

IS-.D-4 252 (a) 0ISTD 6.5.2(b) 1STD-,252(b)

ISTD 6.5.2(c)

ISTD-4252(c)

ISTD 8 IS7-6000 057D 8.5 ISTD-6500 Table ISM 6.5.2-1 Table ISTDJ4252-1 L

3 SPECIFIC REQUIREMENTS 3.1 Examination for Indications of Degradation or Severe Operating Environments Examinations per rSTD 6.1, ISTD 6.2, LSTD 6.3, and 1STD 6.4 shall include examination for indications of degradation and severe operating environments.

1 i

3.2 Examination Prior to Maintenance or Testing All snubbers shall be examined in accordance with the requirements of ISTD 6.1, ISTD 6.2, '5TD 6.3, and ISTD 6.4 and para. 3.1 of this Code Case prior to conduct-ing any maintenance, stroking, or testing, and prior to removai, for any reason, from their installed location.

3.3 Monitoring of Reservoir Fluid Level Fluid level in hydraulic snubber reservoirs shall be sufficient to ensure that the snubber is acceptable for continued service t the next examination interval.

3.4 Review of Operational Readiness Test Data All inservice test data acquired since implementation of the requirements of this Code Case shall be evaluated e or indications of snubber degradation or other anoma-lies. This includes a review of test traces, where available.

The results of this evaluation shall be used (a) to identify snubbers that are subject to progressive degradation 1

(b) to identif. severe operating environments not pre-viously identified C-42 U.oofe9.Sout T.oo Proo-lr%5463410 Not for Romis. 01 21r/S107 07:33:19 MST

CODE CASE OMN-1.3 ASME OM CODE-2004 W,'ere applicabl.e, data gathered prior to implementa-tion of this Code Casa shall aiso be evajuated.

3.6 Transient Dynamic Event The service Life evaluation required by para. 2.1 of this Code Case shall include any transient dynamic event and actions taken under 15TD 1.13.

3.5 Examination During 3,isassembly Snubbers and snubber parts shall be examined for 3.7 Frequency of Examinations indications of degradation and severe operating Unvi-All snubbers within the scoFe of LSTD shall be exam-ronrments during disassernblv (e.g.. during failure evaiu-

ned and evaluated per ESTD 6.1, lSTD 6.3, and iSTD ation, refurbishment).

6.4 at least once every 10 years.

2CYntýt AsME fte~tf

5c,,

i il cterIlen.wihAWE

~.

retttu.-irteC fnr~ktqpeý-itte 1i ft-ens rote 5 401,WSt.t.6'22,07,17;3:19 IST

ATTACHMENT 4 Snubber Interpretations - Information Only Revision 0

Interpretation: 04-10

Subject:

ASME Code-1998 through OMb Code-2000 Date Issued: December 12, 2005 File: OMI 05-04 Question (1): Reference ISTD-4240 and 4252(d). If a snubber reauires further evaluation or is classified as unacceptable during inservice examination and subsequently satisfies the operational readiness test criteria of ISTD-5210, is the snubber required to be classified as unacceptable for the purpose of deter-mining the subsequent visual examination interval in accordance with Table ISTD-4252-1?

Reply (1): No. Per ISTD-4240, test results that satisfy the operational readiness criteria of ISTD-5210 shall be used to accept the snubber., provided the test demonstrates that the unacceptable condition did not affect operational readiness. In such cases, the visual examination requirements of LSTD-4230 are considered to be satisfied.

Question (2): It appears that ISTD-5200 and 5240 are conflicting as to when operational readiness testing can be performed. May inservice operational readiness tests be performed on snubbers at any time during a fuel cycle, normal system operation, or system or plant outages?

Reply (2): No. ISTD-5240 restricts snubber testing from beginning earlier than 60 days before a scheduled refueling outage.

Question (3): It appears that ISTD is silent in relation to subsequent operational readiness testing requirements for a snubber that has failed operational readiness testing and. after corrective action, is installed at a different location than where the failure occurred. Is it a requirement of ISTD-5500 for a snubber that has failed operational readiness testing, then after corrective action and subsequently being installed in a different location, to be retested during the next operational readiness testing campaign?

Reply (3): No.

1-7 Gi*,Oyroht ASM.--