E-mail from Ohara to Tsao, Salem-PSEG Calcs
ML102950268
Person / Time
Site: Salem  PSEG icon.png
Issue date: 05/04/2010
From: O'Hara T
NRC Region 1
To: John Tsao
NRC/NRR/DCI
References
FOIA/PA-2010-0334
Download: ML102950268 (2)


Text

1<~

Conte, Richard From: OHara, Timothy Sent: Tuesday, May 04, 2010 9:21 AM To: Tsao, John Cc: Conte, Richard

Subject:

RE: Salem--PSEG caics John, Presently, PSEG has committed to inspecting Unit 2 in the next outage, spring 2011. However, we did inform them last week that they need a structural integrity evaluation for Unit 2, not just an operability evaluation.

We will probably just debrief from the ISI tomorrow and leave the inspection open for several specific items which PSEG has not addressed. At present I believe there will be a violation for not performing the IWA-5244 required pressure tests for both Unit 1 and 2. We are evaluating several other issues for enforcement.

Tim OHara From: Tsao, John Sent: Tuesday, May 04, 2010 6:52 AM To: OHara, Timothy

Subject:

Salem--PSEG calcs Tim, Thanks. By the way, what is the status of your inspection for the Salem units? When is your exit meeting?

You are going to give the licensee some sort of violation for Unit 2? Do you think the licensee will dig up some portion of unit 2 buried AFW piping and inspect in the next refueling outage?

John From: OHara, Timothy X Sent: Monday, May 03, 2010 3:42 PM To: Manoly, Kamal; Tsao, John Cc: Lupold, Timothy; Conte, Richard

Subject:

FW:

Kamal & John, Attached is the PSEG calc. which goes with the SAI analysis.

Tim OHara From: Berrick, Howard G. [1]

Sent: Monday, May 03, 2010 3:26 PM To: OHara, Timothy

Subject:

FW:

Calculation 6S0-1882 R1 attached Howard Berrick PSEG Nuclear LLC Salem Regulatory Assurance ftwlamat K"J inthis recod w,. delete in 1

  • aolvnce n4th A t.0 r .o. Ir,.matm Act FOtA/PA -- (O - ".'2 '-

PSEG Nuclear - Salem Generating Stations (W) 856-339-1862 (Fax) R ,-139-144 (Bpr) (b)(6) (4 2