Susquehanna Steam Electric "Station.
Units 1 & 2 Radioactive Effluent Release Report 2009 Annual R
Repo6rt-7J j
~Berwvick, PA'
- 'April1 2O1O-ý
RADIOACTIVE EFFLUENT RELEASE REPORT REPORT PERIOD: 01/01/09 - 12/31/09 Prepared by:
Francis J. Hicley Health Physicist
-j*I~2*I Reviewed by:
Rayfnond E. Doebler Chemistry Support Supervisor Approved by:
BrucfE. Rhoads Manager - Plant Chemistry / Environmental PPL Susquehanna, LLC 769 Salem Blvd.
Berwick, Pennsylvania 18603
TABLE OF CONTENTS SECTION PAGE
- 1. Introduction, Summary and Supplemental Information 1-1
- 2. Effluent and Waste Disposal Data 2-1
- 3. Meteorological Data and Dispersion Estimates 3-1
- 4. Dose Measurements and Assessments 4-1
- 5. Changes to the Offsite Dose Calculation Manual (ODCM),
5-1 Technical Requirements Manual (TRM) and the Solid Radioactive Waste Process Control Program
- 6. Miscellaneous Technical Requirements Manual (TRM), FSAR, 6-1 40CFR190 and NEI Groundwater Protection Initiative Reporting
- 7. Corrections to Previous Radioactive Effluent Release Reports 7-1
- 8. Effluent from Systems Classified as Insignificant Effluent Pathways 8-1 Appendix A ODCM/TRM
LIST OF TABLES Table Table Table Table Table Table 1-1 2-1 2-2 2-3 2-4 2-5 Table 2-6 Table 2-7 Table 2-8 Table 2-9 Table 2-10 Technical Requirement Limits Airborne Effluent - Summation of All Releases Airborne Effluent - Radionuclides Released Waterborne Effluent - Summation of All Releases Waterborne Effluent - Radionuclides Released Estimated Total Errors Associated with Effluents Measurements Waste Disposition CFS Backwash - Class A HIC (Pyrolysis)
CFS Filters - Class A HIC (Pyrolysis)
Condensate Demineralizer / Radwaste Demineralizer Class A HIC (Pyrolysis)
Liquid Radwaste Filter Media - Class A HIC (Pyrolysis)
Processed DAW - Class A HIC (Compacted)
Processed DAW - Class A Strong Tight Container (Compacted)
Sump Sludge - Class A (Pyrolysis)
PAGE 1-10 2-4 2-5 2-8 2-9 2-12 2-15 2-16 2-17 2-18 2-19 2-20 2-21 Table Table 2-11 2-12 Table 2-13 2-22
LIST OF TABLES (cont.)
Table 3-1 Meteorological Data Recovery for 2009 PAGE 3-3 3-4 Table 3-2 Table 3-3 Joint Frequency Distribution of Wind Speed and Wind Direction 1 Om versus Delta Temperature 60-1 Om for the Period of January 1, 2009 through December 31, 2009 Joint Frequency Distribution of Wind Speed and Wind Direction 60m versus Delta Temperature 60-1 Om for the Period of January 1, 2009 through December 31, 2009 Table 3-4 2009 SSES Annual Relative Concentrations No Decay, Undepleted X/Q (sec/m3)
Table 3-5 2009 SSES Annual Relative Concentrations 2.26-Day Decay, Undepleted X/Q (sec/m3) 3-12 3-20 3-21 3-22 3-23 3-24 4-2 Table 3-6 2009 SSES Annual Relative Concentrations 8-Day Decay, Depleted X/Q (sec/m3)
Table 3-7 Table 3-8 2009 SSES Annual Relative Deposition (D/Q meters-2) 2009 Atmospheric Dispersion Estimates for RETDAS Input at Selected Locations Table 4-1 Site-Specific Parameters Used for RETDAS Calculations (Danville Receiver) for 2009 Table 4-2 Table 4-3 Summary of Maximum Individual Doses to Members of the Public Data Period: 1/1/09 to 12/31/09 Calculated Collective Doses to Members of the Public Within the Riverlands/Energy Information Center Complex Data Period: 1/1/09 to 12/31/09 4-4 4-5 Table 4-4 Summary of Maximum Individual Doses from Airborne Effluent 4-6 Table 6-1 NEI Ground Water Protection Initiative Reporting 6-4 Table 8-1 Annual Release from Systems Classified as 8-3 Insignificant Effluent Pathways
LIST OF FIGURES Figure 1-1 Figure 1-2 Figure 2-1 Figure 2-2 Figure 3-1 Figure 3-2 Figure 3-3 Figure 4-1 Figure 6-1 Airborne Effluent Release Points Waterborne Effluent Pathway Susquehanna River Monthly Average Flow Rates Data Period: 2009 Monthly Liquid Radwaste Discharge Totals 2009 Annual Wind Rose 1 OM Level -
Primary Tower 2009 Annual Wind Rose 60M Level -
Primary Tower Pasquil Stability Class Prevalences Data Period: 2009 Airborne-Dose Calculation Locations SSES Tritium Effluent Releases PAGE 1-6 1-7 2-10 2-11 3-26 3-27 3-28 4-7 6-5
SECTION 1 INTRODUCTION,
SUMMARY
AND SUPPLEMENTAL INFORMATION 1-1
INTRODUCTION The submittal of the 2009 Radioactive Effluent Release Report is in accordance with PPL Susquehanna, LLC Tech Spec. 5.6.3. The enclosed information is consistent with the objectives outlined in the Offsite Dose Calculation Manual (ODCM) and Process Control Program (PCP). The 2009 Radioactive Effluent Release Report is in conformance with 10CFR50.36a and 10CFR50, Appendix I, Section IV.B.1.
PPL Susquehanna, LLC is located in Salem Township, Luzerne County, Pennsylvania.
It is on the west bank of the Susquehanna River, 8 km northeast of Berwick. The station consists of two boiling water reactor generating units. Each unit is progressing through an Extended Power Uprate process which will result in an increase of licensed thermal power from 3489 MWt (megawatt thermal) to 3952 MWt. Unit-1 is scheduled to complete the power uprate in 2010 and Unit 2 is scheduled to complete the uprate in 2011. The reactor and generating units were supplied by General Electric, while the Bechtel Corporation served as architect-engineer and constructor.
Construction of the Station began in the early 1970s. Fuel load began in Unit 1 in July of 1982. Initial criticality was achieved in the Unit 1 reactor on September 10, 1982.
The reactor reached 100% power for the first time on February 4, 1983. Commercial operation of Unit 1 was declared on June 8, 1983. Initial criticality of Unit 2 occurred on May 8, 1984. Unit 2 was declared commercial on February 12, 1985.
Airborne effluents are released from the Station via five rooftop vents on the reactor building (see Figure 1-1). Continuous sampling for particulates and iodines is performed at each vent as well as continuous monitoring for noble gases. A program of periodic sampling and analysis for tritium and noble gases along with periodic analysis of particulate and iodine samples is conducted as specified in the plant Technical Requirements. All waterborne effluents are released in batch mode and are sampled and analyzed prior to release. Waterborne effluents from the site are released into the cooling tower blowdown line for dilution prior to release to the Susquehanna River (see Figure 1-2). Blowdown line flow rates are at least 5,000 gpm during periods of liquid radwaste release. The diluted effluent is introduced to the river by way of a perforated diffuser pipe placed on the river bed. The diffuser serves to rapidly and uniformly mix the station discharge with the main flow of the river.
This report presents a summary of the quantities of radioactive materials which were released from the Station during the period from January 1, 2009 to December 31, 2009. In addition, this report serves as a medium for notifying the US Nuclear Regulatory Commission staff of changes to the ODCM, PCP and documentation of any exceptions to the effluent monitoring program which must be reported per Technical Requirements.
Airborne and waterborne radioactive effluent releases to the environment during the report period were sampled and analyzed in accordance with the Technical 1-2
Requirements. All radioactive effluent releases were within the concentration and release limits specified in the Technical Requirements. Calculations and terms utilized in this report are those outlined in the ODCM.
Section 1 contains supplemental information pertaining to effluents from the Susquehanna plant. Included are regulatory limits (Table 1-1), sampling and analysis methods, characterization of the number and duration of batch and abnormal releases and a brief summary of the applicable year's effluents.
Section 2 contains effluent and waste disposal data for the report period. Table 2-1 contains a summation of all airborne releases, grouped into the radionuclide categories of gases, particulates, iodines, and tritium. Average release rates are presented and compared to the applicable limits. Table 2-2 presents the activity totals of specific radionuclides in airborne effluents.
Waterborne effluents are summarized in Table 2-3. Average diluted concentrations are presented and compared to the applicable limits. Table 2-4 presents the release quantities of specific radionuclides in waterborne effluents over the report period.
Figures 2-1 and 2-2 present the Susquehanna River Monthly Average Flow Rates for 2009 and the Monthly Liquid Radwaste Discharge Totals for 2009, respectively.
Table 2-5 contains estimates of the errors associated with the measurements involved in quantifying effluents. Sampling errors, counting errors, and errors associated with determining effluent flow rates and volumes all contribute to the total error of effluent measurements. Error estimates are presented for each category of radionuclide detected in airborne and waterborne effluents and solid wastes during the report period.
Tables 2-7 through 2-13 present a characterization of the solid radioactive waste shipped offsite during the report period. An estimate of major nuclide composition is presented for each waste type. Also included are the volumes and curie contents associated with each type of solid waste. The number of waste shipments from the site transported directly for burial or disposal are listed in Table 2-6.
Section 3 presents meteorological data for 2009, including data recovery, joint frequency distribution of wind speed and direction, stability class distribution, and atmospheric dispersion estimates for selected locations.
Section 4 of this report contains an assessment of the calculated doses attributed to the reported radiological effluents for the calendar year. The Radioactive Effluent Tracking and Dose Assessment Software (RETDAS) computer code was used for calculation of doses from waterborne effluents. Site-specific parameters used in the calculations for the Danville receiver are shown in Table 4-1. The RETDAS code was also used for calculation of doses from airborne effluents. The calculated doses and direct radiation estimates can be used to estimate the doses to maximally exposed members of the public. Table 4-2 summarizes maximum calculated doses to members of the public from airborne and waterborne effluents. Table 4-3 presents calculated collective doses 1-3
to members of the public within the Riverlands/Energy Information Center Complex.
Table 4-4 summarizes the calculated doses for residences and other occupied areas within the site boundary and the nearest dairy.
Section 5 of this report documents changes to the Offsite Dose Calculation Manual, Technical Requirements Manual and the Solid Radioactive Waste Process Control Program.
Section 6 presents a listing of cases (if any) in which airborne or waterborne effluent monitoring instrumentation was declared inoperable and was not restored to operability within the time period specified in Technical Requirements 3.11.1.4, 3.11.1.5 and 3.11.2.6 Action Statements. In addition, this section presents issues (if any) with the collection of milk or fresh leafy vegetables per Technical Requirement 3.11.4.1 and changes due to the land use census per Technical Requirement 3.11.4.2. Section 6 also includes reporting associated with the Nuclear Energy Institute (NEI) Groundwater Protection Initiative.
Section 7 contains corrections (if any) to previous Radioactive Effluent. Release Reports.
Section 8 contains information on effluent and offsite dose from the systems classified as insignificant effluent pathways.
1-4
SUMMARY
Liquid effluent releases for 2009 were similar to those of previous years. During 2009 there were eighty-three (83) liquid batch releases resulting in a total release volume of five hundred thirty-two thousand two hundred (532,200) gallons. The total number of liquid batch releases and total volume released in 2009 was lower than the corresponding values for 2008 (89 releases resulting in 700,900 gallons released in 2008). The predominant radionuclide released inliquid effluents during 2009 was tritium. Approximately twenty-three (23) curies of tritium were released in liquid effluents in 2009, compared to thirty-three (33) curies released in 2008. When compared with all radionuclides released in liquid effluents in 2009, Co-60 and tritium were the main contributors to the resultant offsite dose. Consistent with previous years, the offsite dose from liquid releases in 2009 was less than one percent (1%) of the annual limits for both organ and whole body dose.
Gaseous effluents for 2009 were also comparable to those of previous years. The predominant radionuclide released in gaseous effluents was tritium. When compared with all radionuclides released in gaseous effluents in 2009, tritium was the main contributor to the resultant offsite dose. Approximately thirty-eight (38) curies of tritium were released in gaseous effluents in 2009 compared to sixty (60) curies in 2008. The resultant maximum offsite organ dose due to gaseous effluents from Unit-1 for 2009 was 1.48E-01 mrem, which is 1.0 percent (1.0%) of the per unit annual limit of fifteen (15) mrem. The resultant maximum offsite organ dose due to gaseous effluents from Unit-2 for 2009 was 1.98E-01 mrem, which is 1.3 percent (1.3 %) of the per unit annual limit of fifteen (15) mrem. The maximum offsite dose from gaseous effluents was lower in 2009 when compared with 2008 (1.98E-01 vs. 4.21 E-01 mrem) due to a decrease in tritium released from the Unit-2 Turbine vent. The main source of the tritium in liquid and gaseous effluents is from control rod blades.
1-5
FIGURE 1-1 AIRBORNE EFFLUENT RELEASE POINTS SUNI11T I
UNIT 11 RE ACO R
REACTOR 9
BUIDN BUILDING EXAUST EXHAUST V ENT VENT 160,770 CFM AT 600 F-110(F 157.350 CFM AT 60"F-I110 0 F 302,959 CFM 17,500 CFM T I0OOF-120°F AT 120OF UNIT I
'TURBINE BUILDING EXHAUST VENT DIESEL 1-6
FIGURE 1-2 WATERBORNE EFFLUENT PATHWAY e [
FROM EVAPOR ATOR HEATING I
REACTOR WELL SEAL LEAK DRAIN STEAM CONDENSATE RETURN TANKRECOBULIGDA (DECANTV)
DRYWELL DRAINS I
FROM RHR SYSTEM (SUPPRESSION POOL TRANSFERS)
TURBINE BUILDING DRAINS I RADW ASTE BUILDING DRAINS Il I
1 RADW ASTE BUILDING DRAINS I,*
I*LIQUID I
LIQUID EFFLUENT RELEASE FLOWPATH I
(M-161, M-162, M-163 AND M-164)
RADWASTE RECYCLE LIQUID RADWASTEI COLLECTION AND I
BSU RG E TA N KS II OT-304A THRU D° ATAO AT,
FILTERS DEMINERALIZER SA PETN LIQUID 0AW ST F-302A & B 0-3
_01 O -
0 A T R
CO LLECTION TANK PUMPS
.qCO 0P-3 0 1 A, B & CS TO TO SW SMSLIQUID RADWASTE SAMPLE TANK PUMPS I
RADWASTE BUILDING FULPOILAU SA MPLE STATION SYSTEM CHEMICAL DE CO I RW CU CHEMICAL DECON..
CHEMICAL DECON LAB & DEC ON DAINýS I I
UX,
BOILER BLOWDOWNS C E CA W STI CHEMICAL DRAIN TANK Ii i
TANK OT-314 4
A DVIA STE I
DIST I LLATE0T 2
' V A P O R A T O R S S A M P L E T A N K CHEMICAL WASTE TANK 0E-302A, B (1)T12 I2(2)
CONDENSATE DEMIN L.
RESIN REGEN. TANKS EVAPORATOR SSTORAGE TANK D S IL T
C H E M IC A L W A S T E O T -3 2 2 T N INEUTRALIZING III SAMPLE STN S TANKS I
oJPUMPs 1T-13 OA,
B IO-2A 2T-13 0A,
B
.l Ii CHEMICAL WASTE CO DNST ST RGETN L
NEpUITR
- AL ZING TAN-KIPUAMPBSCDIsEART SOpApT2N
._ I P R O C E S S N G I
"-I SYSTEM I
PERSONNEL DECONTAMINATION L(DDETERGENTS)
I FLOOR DECON (SOLUTIONS)
CASK CLEANING DRAI NS LAUNDRY DRAIN ILAUNDRY DRAIN LAUNDRY DRAIN TANKS FILTERS SA MPLE TANKS 0T
- 3 1 1 1 A, B 0F
- 3 1I3 A
1-A 3 O T - 3 1 2 LAUNDRY DRAIN nF313l "IB _3' TANK PUMPS LAUNDRY DRAIN
/
o P #-3 S A,
_B NDENSATE STORAGE TANKS
-522A & B (1) RADWASTE EVAPORATORS ARE NOT USED (2) COND DEMIN RESINS CURRENTLY NOT REGENERATED (3) CONTAMINATED CLOTHING CURRENTLY NOT LAUNDERED ONSITE SUSQUEHANNA RIVER 1-7
SUPPLEMENTAL INFORMATION
- 1.
Regulatory Limits Technical Requirements 3.11.1 and 3.11.2 outline requirements for release of radioactive liquid and gaseous effluents, respectively. Concentration of radioactive materials released in liquid effluents and resulting dose are limited in unrestricted areas. Dose and dose rate due to radioactive materials released in gaseous effluents are limited in areas at or beyond the site boundary. Technical Requirement limits are listed in Table 1-1.
- 2.
Maximum Permissible Concentrations in Waterborne Effluents The concentration of radioactive material released in liquid effluents to unrestricted areas is limited to 10 times the concentrations specified in 10 CFR Part 20 Appendix B Table 2, Column 2, for radionuclides other than dissolved or entrained noble gases.
For dissolved or entrained noble gases, the concentration is limited to 2.OE-04 pCi/ml total activity (TRO 3.11.1.1).
- 3.
Average Energy of Fission and Activation Gas The Calculation of Noble Gas Effluent Average Energies E-Bar Beta and Gamma was not performed due to the fact that no noble gases were measured in station vent air samples above detection limits during 2009.
- 4.
Measurements and Approximations of Total Radioactivity Analyses of specific radionuclides in effluent samples are used to evaluate the radioactive composition and concentration of effluents.
- 5.
Methods of Quantifying Effluents
- a.
Fission and Activation Gases: Gas samples are routinely collected monthly and analyzed with a high resolution (HPGE) detector system which incorporates a data reduction program to determine radionuclide composition in terms of specific activity. Data from the continuous vent monitors are used to determine the average concentration of noble gases. The high resolution (HPGE) isotopic scan is used to convert the continuous vent monitor activity to actual activity based on the determined nuclide mixture. The vent and sample flow rates are continuously monitored and the average flow rates for each vent are used to calculate the total activity released in a given time period. When the continuous monitors are out of service, manual grab 1-8
samples are taken from each vent once each eight hours (once each four hours for the standby gas treatment vent).
- b.
lodines: Iodine is continuously collected on charcoal or silver zeolite cartridges via an isokinetic sampling assembly in each vent. Filters are normally exchanged once per week and analyzed on a high resolution (HPGE) system. The daily average flow rates for the vents and sample pumps are averaged for the duration of the sampling period and a ratio of vent flow rate to sample flow rate is determined. The ratio is used to determine the total activity of each isotope released during the time period in question. When the continuous samplers are out of service, iodine is continuously collected from alternate sampling ports available on the sample lines or directly from the affected rooftop vent(s).
- c.
Particulates: Particulates are continuously collected via an isokinetic sampling assembly in each vent. Filters are normally exchanged once per week and analyzed on a high resolution (HPGE) system. Flow rate corrections are performed as for iodines. When the continuous samplers are out of service, particulates are continuously collected from alternate sampling ports available on the sample lines or directly from the affected rooftop vent(s).
- d.
Tritium: Airborne tritium is collected monthly via bubbler sampler. The sample is collected for one hour at a flow rate of approximately 1000 cc/min.
Tritium activity in the bubbler sample is determined by liquid scintillation counting. The liquid sample tritium concentration is then converted to air concentration by volume proportion.
- e.
Waterborne Effluents: Each tank of liquid radwaste is sampled and analyzed for principal gamma emitters prior to release. Each sample tank is recirculated for a sufficient amount of time prior.to sampling to ensure that a representative sample is obtained. Samples are analyzed on a high resolution (HPGE) system and release permits are generated based on the values obtained from the isotopic analysis and the most recent values for tritium, gross alpha, iron-55, and strontium-89 and -90. An aliquot based on release volume is saved and added to monthly and quarterly composite containers. The monthly tritium analysis is done in-house. A monthly composite is sent to a vendor laboratory for gross alpha analysis. A quarterly composite is sent to a vendor laboratory for iron-55, strontium-89 and-90 analyses.
The concentration of each radionuclide in each batch is multiplied by the volume of the batch to determine the total quantity of each nuclide released in each batch. The isotopic totals for each batch are summed to determine the total source term for the report period.
1-9
TABLE 1-1 TECHNICAL REQUIREMENT LIMITS A.
NOBLE GASES:
- 1.
- 500 mrem/year - TOTAL BODY
- 3000 mrem/year - SKIN dose rate limit at and beyond the site boundary (TRO 3.11.2.1.1)
- 2.
- 5 mrad - AIR GAMMA
- __10 mrad - AIR BETA quarterly air dose limits per reactor unit at and beyond the site boundary (TRO 3.11.2.2a)
- 3.
- 10 mrad - AIR GAMMA
- 20 mrad - AIR BETA annual air dose limits per reactor unit at and beyond the site boundary (TRO 3.11.2.2.b)
B.
AIRBORNE 1-131,1-133, TRITIUM, PARTICULATES WITH HALF-LIVES > 8 DAYS:
- 1.
- 1500 mrem/year - ORGAN (inhalation pathways only) dose rate limit at and beyond the site boundary (TRO 3.11.2.1.II.A)
- 2.
___7.5 mrem - ORGAN quarterly dose limit per reactor unit at and beyond the site boundary (TRO 3.11.2.3.a)
- 3.
515 mrem - ORGAN annual dose limit per reactor unit at and beyond the site boundary (TRO 3.11.2.3.b) 1-10
C.
LIQUID EFFLUENTS:
- 1.
- 1.5 mrem - TOTAL BODY
- _5.0 mrem - ORGAN quarterly dose limits per unit (TRO 3.11.1.2.a)
- 2.
- _3.0 mrem - TOTAL BODY
- 10.0 mrem - ORGAN annual dose limits per unit (TRO 3.11.1.2.b)
D.
AIRBORNE EFFLUENT: BASES FOR PERCENT OF APPLICABLE LIMIT VALUES IN TABLE 2-1 Fission and Activation Gases Derived release rate limits based on the Technical Requirement (TRO 3.11.2.1.1.A and B) limits of 500 mrem/yr to the total body and 3000 mrem/yr to the skin were calculated (PPL calculation EC-ENVR-1 041 Rev. 2) from the expected mix of noble gas radionuclides presented in Attachment A of ODCM-QA-003, Effluent Monitor Setpoints. The lower limit of 1.00E+06 pCi/min (1.67E+04 pCi/sec) based on total body dose rate is used.
Iodine-131 A derived release rate limit for 1-131 based on the Technical Requirement (TRO 3.11.2.1.lI.A) limit of 1500 mrem/yr from 1-131, 1-133, tritium and particulates with half-lives greater than 8 days was calculated (PPL calculation EC-ENVR-1041 Rev. 2) based on the ratio of the expected annual release quantities of 1-131 and 1-133 provided in Attachment E of ODCM-QA-004, Airborne Effluent Dose Calculations. The limit is 1.04E+02 pCi/min I-131 (1.73E+00 pCi/sec).
Particulates A derived release rate limit for particulate activity other than iodines based on the Technical Requirement (TRO 3.11.2.1.lI.A) limit of 1500 mrem/yr from I-131, 1-133, tritium and particulates with half-lives greater than 8 days was calculated (PPL calculation EC-ENVR-1 041 Rev. 2) based on the expected annual release quanities of particulate radionuclides provided in Attachment E of ODCM-QA-004, Airborne Effluent Dose Calculations. The limit is 3.02E+03 pCi/min (5.03E+01 pCi/sec).
1-11
Tritium A derived release rate was calculated based on the 10 CFR 20, Appendix B, Table 2, Column 1, Effluent Concentration Limit for tritium (1.0E-07 pCi/cc) to unrestricted areas. A relative concentration of 4.1 E-05 sec/m 3 was assumed (PPL calculation EC-ENVR-1 040). The limit is 1.46E+05 pCi/min (2.44E+03 pCi/sec).
Radionuclide Fractional Summation The sum of the percents of applicable limits for particulates, iodine and tritium must be less than 100%.
E.
WATERBORNE EFFLUENT: BASES FOR PERCENT OF APPLICABLE LIMIT VALUES IN TABLE 2-3 Fission and Activation Products Concentrations of fission and activation products in liquid effluent from radwaste effluent are determined for each batch prior to release. Each isotope concentration is compared to ten times the 1 OCFR20 Appendix B, Table 2, Column 2 Effluent Concentration Values (TRO 3.11.1.1).
Tritium Liquid effluent quarterly tritium concentrations are compared to ten times the 10 CFR 20 Appendix B, Table 2, Column 2, Effluent Concentration value of 1.OE-03 pCi/ml to unrestricted areas.
Dissolved and Entrained Gases Liquid effluent concentrations for dissolved and entrained gases are compared to the limiting value for total noble gas activity of 2.OE-04 pCi/ml (TRO 3.11.1.1).
Radionuclide Fractional Summation The sum of the percents of applicable limits for fission and activation products, tritium and dissolved and entrained gases must be less than 100%.
1-12
SECTION 2 EFFLUENT AND WASTE DISPOSAL DATA 2-1
Airborne Effluents Summaries of the radionuclide total curie activities and average release rates are included in Tables 2-1 and 2-2. If a radionuclide was not detected, zero activity was used for that isotope in dose calculations and the activity is listed as "<MDC" (less than the minimum detectable concentration) in Tables 2-1 and 2-2. <MDC indicates that no activity was positively detected in any sample when samples were analyzed with techniques which achieved the required Lower Limits of Detection (LLD) as specified in the Technical Requirement (TRO) Table 3.11.2.1 -1, Radioactive Gaseous Effluent Sampling and Analysis Program. In all cases, the measurement laboratory MDCs were at or below the LLD levels required by Technical Requirements. The following are typical measurement laboratory MDCs.
Typical MDCs Radionuclide MDC (pCi/cc)
Kr-87 4.3 E-08 Kr-88 4.6 E-08 Xe-1 33 3.0 E-08 Xe-133m 1.1 E-07 Xe-1 35 1.5 E-08 Xe-135m 8.0 E-08 Xe-138 1.5 E-07 Mn-54 2.9 E-13 Fe-59 2.8 E-13 Co-58 1.8 E-13 Co-60 3.8 E-13 Zn-65 1.0 E-13 Mo-99 1.0 E-12 Cs-1 34 2.4 E-13 Cs-137 1.1 E-13 Ce-141 1.0 E-13 Ce-144 5.0 E-13 1-131 4.4 E-14 Sr-89 1.1 E-13 Sr-90 1.3 E-14 H-3 1.5 E-08 Gross Alpha 2.3 E-14 Batch Releases
- 1. Number of Batch Releases:
0
- 2. Total Time Period for Batch Release:
NA
- 3. Maximum Time Period for a Batch Release:
NA
- 4. Average Time Period for a Batch Release:
NA
- 5. Minimum Time Period for a Batch Release:
NA 2-2
Abnormal Releases
- 1. Number of Releases 1V
- 2. Total Activity Released NA
- On April 7, 2009 the auxiliary steam system was identified as contaminated with low levels of tritium (-2E-5 uCi/cc). Conservative assumptions were used in support of the calculation of total radioactive effluent from operation of the auxiliary steam system on April 7, 2009. The radioactive effluent due to auxiliary steam system operation on April 7, 2009 is a small fraction
(<0.001 %) of the total releases due to station operation in 2009. Additional details on this release are outlined in Section 8.
2-3
TABLE 2-1 AIRBORNE EFFLUENT - SUMMATION OF ALL RELEASES First Second Third Fourth Unit Quarter Quarter Quarter Quarter A. Fission and Activation Gas Total Release Ci
<MDC
<MDC
<MDC
<MDC Average Release Rate for Period pJCi/sec 0
0 0
0 Percent of Applicable Limit (1.67E+04 0
0 0
0 pCi/sec)
B. lodines Total 1-131 Ci
<MDC
<MDC
<MDC
<MDC Average Release Rate for Period IpCi/sec 0
0 0
0 Percent of Applicable Limit (1.73E+00 0
0 0
0 pICi/sec)
C. Particulate W
-Particulate with Half-Life >8 Days Ci
<MDC 1.17E-04 8.75E-05 5.85E-06 4W Average Release Rate for Period PCi/sec 0
1.49E-05 1.10E-05 7.36E-07 Percent of Applicable Limit (5.03E+01 0
2.96E-05 2.19E-05 1.46E-06 Gross Alpha Radioactivity Ci
<MDC
<MDC
<MDC
<MDC D.
Tritium Total Release Ci 1.69E+01 4.95E+00 3.45E+00 1.22E+01 Average Release Rate for Period JpCi/sec 2.17E+00 6.30E-01 4.34E-01 1.53E+00 Percent of Applicable Limit,(2.44E+03 8.90E-02 2.58E-02 1.78E-02 6.28E-02 pCi/sec)
E.
Radionuclide Fractional Summation Sum of Percent of Applicable Limit 0.09 0.03 0.02 0.06 During Period for C and D (Limit 100%)
2-4
TABLE 2-2 AIRBORNE EFFLUENT - RADIONUCLIDES RELEASED Releases in Continuous Mode First Second Third Fourth Nuclides Released Unit Quarter Quarter Quarter Quarter A. Fission and Activation Gases Ar-41 Ci
<MDC
<MDC
<MDC
<MDC Kr-85 Ci
<MDC
<MDC
<MDC
<MDC Kr-85m Ci
<MDC
<MDC
<MDC
<MDC Kr-87 Ci
<MDC
<MDC
<MDC
<MDC Kr-88 Ci
<MDC
<MDC
<MDC
<MDC Kr-89 Ci
<MDC
<MDC
<MDC
<MDC Xe-133 Ci
<MDC
<MDC
<MDC
<MDC Xe-135 Ci
<MDC
<MDC
<MDC
<MDC Xe-1 35m Ci
<MDC
<MDC
<MDC
<MDC Xe-137 Ci
<MDC
<MDC
<MDC
<MDC Xe-138 Ci
<MDC
<MDC
<MDC
<MDC Total for Period Ci 0
0 0
0 B. lodines 1-131 Ci
<MDC
<MDC
<MDC
<MDC 1-133 Ci
<MDC
<MDC
<MDC
<MDC A
1-135 Ci
<MDC I
<MDC I
<MDC I
<MDC w
Total for Period Ci 0
0 0
0 C. Particulate Cr-51 Ci
<MDC
<MDC
<MDC
<MDC Mn-54 Ci
<MDC 1.04E-05 3.64E-05 5.85E-06 Fe-59 Ci
<MDC
<MDC
<MDC
<MDC Co-57 Ci
<MDC
<MDC
<MDC
<MDC Co-58 Ci
<MDC
<MDC
<MDC
<MDC Co-60 Ci
<MDC 1.07E-04 5.11 E-05
<MDC Zn-65 Ci
<MDC
<MDC
<MDC
<MDC Sr-89 Ci
<MDC
<MDC
<MDC
<MDC Sr-90 Ci
<MDC
<MDC
<MDC
<MDC Cs-1 34 Ci
<MDC
<MDC
<MDC
<MDC Cs-137 Ci
<MDC
<MDC
<MDC
<MDC Ce-141 Ci
<MDC
<MDC
<MDC
<MDC Ce-144 Ci
<MDC
<MDC
<MDC
<MDC Nb-95 Ci
<MDC
<MDC
<MDC
<MDC Ba-La-140 Ci
<MDC
<MDC
<MDC
<MDC Total for Period Ci 0
1.17E-04 8.75E-05 5.85E-06 2-5
Waterborne Effluents Summaries of the radionuclide total curie activities, average diluted concentrations, and percent of applicable Technical Requirement limits are included in Tables 2-3 and 2-4.
Batch Releases*
- 1.
Number of Batch Releases
- 2.
Total Time Period for a Batch Release
- 3.
Maximum Time Period for a Batch Release
- 4.
Average Time Period for a Batch Release
- 5.
Minimum Time Period for a Batch Release
- 6.
Average Cooling Tower Blowdown Flow Rate During Periods of Release
- 7.
Susquehanna River Flow Rate
- Units of time and flow are expressed respectively.
Qtr. 1 29 1.84E+03 8.OOE+01 Qtr. 2 30 3.91 E+03 2.94E+02 Qtr. 3 Qtr. 4 10 5.92E+02 8.OOE+01 14 9.66E+02 9.60E+01 Annual 83 7.30E+03 2.94E+02 8.80E+01 2.80E+01 6.35E+01 1.30E+02 5.92E+01 6.90E+01 2.80E+01 3.OOE+01 3.OOE+01 3.OOE+01 7.20E+03 7.92E+03 1.19E+04 8.83E+03 8.18E+03 8.29E+06 6.06E+06 3.50E+06 5.39E+06 5.80E+06 in minutes and gallons per minute (gpm),
If a radionuclide was not detected, zero activity was used for that isotope in dose calculations and the activity is listed as "<MDC" (less than the miniumum detectable concentration) in Tables 2-3 and 2-4. <MDC indicates that no activity was positively detected in any sample when samples were analyzed with techniques which achieved the required Lower Limits of Detection (LLD) as specified in the Technical Requirement 3.11.1.1-1, Radioactive Liquid Waste Sampling and Analysis Program. In all cases, the measurement laboratory MDCs were at or below the LLD levels required by Technical Requirements. The following are typical measurement laboratory MDCs.
Radionuclide Mn-54 Fe-59 Co-58 Co-60 Zn-65 Mo-99 1-131 Cs-134 Cs-137 Ce-141 Ce-144 Sr-89 Sr-90 Fe-55 H-3 Gross Alpha MDC (pCi/ml) 4.5 E-08 5.0 E-08 4.0 E-08 5.4 E-08 4.9 E-08 1.7 E-07 2.0 E-08 2.2 E-08 2.6 E-08 3.2 E-08 1.3 E-07 4.4 E-08 1.6 E-08 8.2 E-07 3.6 E-06 3.7 E-09 2-6
Abnormal Releases
- 1.
Number of releases 0
0 0
0
- 2.
Volume Released N/A N/A N/A N/A
- 3.
Total Activity Released N/A N/A N/A N/A 2-7
TABLE 2-3 WATERBORNE EFFLUENT - SUMMATION OF ALL RELEASES First Quarter Second Quarter Third Quarter Fourth Quarter A. Fission and Activation Products Unit
- 1. Total Release (excluding: Tritium, Ent.
Gases, Alpha)
Ci 4.36E-04 2.28E-03 2.1OE-03 3.97E-03
- 2. Average Diluted Concentration During Period jCi/ml 8.70E-09 11.95E-08 7.88E-08 1.23E-07
- 3. Sum of Average Diluted Cr/Ln Ratio During Period Unitless 2.23E-04 4.76E-04 2.33E-03 3.84E-03
- 4. Percent of Applicable Limit (Ratio < 1.0) 0.02 0.05 0.23 0.38 B. Tritium
- 1. Total Release Ci 6.55E+00 1.31 E+01 1.06E+00 2.17E+00
- 2. Average Diluted Concentration During Period Ci/mI 1.31 E-04 1.12E-04 3.97E-05 6.72E-05
- 3. Percent of Applicable Limit (1.OE-2 pCi/ml) 1.31 1.12 0.40 0.67 C. Dissolved and Entrained Gases
- 1. Total Release Ci
<MDC
<MDC
<MDC
<MDC
- 2. Average Diluted Concentration PCi/ml 0.OOE+00 0.OOE+00 0.OOE+00 0.OOE+00 During Period 3, Percent of Applicable Limit (2.OE-4 pCi/ml) 0.OOE+00 0.OOE+00 0.OOE+00 0.OOE+00 D. Radionuclide Fractional Summation
- 1. Sum of Percent of Applicable Limit During Period for A, B and C (Limit = 100%)
1.33 1.17 0.63 1.05 E. Gross Alpha Radioactivity F1. Total Release Ci
<MDC 1.30E-05 2.03E-06 7.25E-06 F. Volume of Water Released (Prior to Dilution)
G. Volume of Dilution Water Used During Period of Release H. Volume of Dilution Water Used Over Entire Period Gallons 1.27E+05 I 3.02E+05 I 3.82E+04 6.48E+04 I
Liters 4.80E+05 1.14E+06 1.45E+05 2.45E+05 Gallons 1.31E+07 3.06E+07 I 7.OOE+06 I 8.46E+06 Liters 4.97E+07 1.16E+08 2.65E+07 3.20E+07 Gallons 9.36E+08 I 1.01E+09 1.53E+09 1.28E+09 Liters 3.54E+09 3.81 E+09 5.78E+09 4.83E+09 2-8
TABLE 2-4 WATERBORNE EFFLUENT - RADIONUCLIDES RELEASED Releases in Batch Mode Nuclides Unit First Second Third Fourth Released Quarter Quarter Quarter Quarter A. Fission and Activation Products Na-24 Ci
<MDC
<MDC
<MDC
<MDC Cr-51 Ci
<MDC 1.49E-04
<MDC
<MDC Mn-54 Ci 2.33E-06 1.06E-04 1.23E-05 6.84E-06 Fe-55 Ci
<MDC
<MDC
<MDC
<MDC Co-58 Ci 1.05E-04 4.16E-04 2.68E-04 2.67E-04 Fe-59 Ci
<MDC 1.02E-05
<MDC
<MDC Co-60 Ci 3.05E-04 1.59E-03 1.82E-03 3.66E-03 Zn-65 Ci 2.43E-05 1.01 E-05
<MDC 3.67E-05 Sr-89 Ci
<MDC
<MDC
<MDC
<MDC Sr-90 Ci
<MDC
<MDC
<MDC
<MDC Nb-95 Ci
<MDC 1.14E-06
<MDC
<MDC Rh-105 Ci
<MDC
<MDC
<MDC
<MDC Sb-124 Ci
<MDC 1.13E-06
<MDC
<MDC Ce-141 Ci
<MDC
<MDC
<MDC
<MDC Ta-182 Ci
<MDC
<MDC
<MDC
<MDC Total for Period Ci 4.36E-04 2.28E-03 2.1 OE-03 3.97E-03 B. Tritium Total for Period Ci 6.55E+00 1.31 E+01
=1.06E+00 2.17E+00 C. Dissolved and Entrained Gases Ar-41 Ci
<MDC
<MDC
<MDC
<MDC Kr-85 Ci
<MDC
<MDC
<MDC
<MDC Kr-85m Ci
<MDC
<MDC
<MDC
<MDC Kr-87 Ci
<MDC
<MDC
<MDC
<MDC Kr-88 Ci
<MDC
<MDC
<MDC
<MDC Xe-131m Ci
<MDC
<MDC
<MDC
<MDC Xe-133m Ci
<MDC
<MDC
<MDC
<MDC Xe-1 33 Ci
<MDC
<MDC
<MDC
<MDC Xe-135m Ci
<MDC
<MDC
<MDC
<MDC Xe-135 Ci
<MDC
<MDC
<MDC
<MDC Total for Period Ci 0
0 0
0 2-9
Figure 2-1 Susquehanna River Monthly Average Flow Rates Data Period: 2009 14.0 12.0 0.
0) 0 10.0 8.0 6.0 4.0 2.0 0.0 2009 2-10
Figure 2-2 Monthly Liquid Radwaste Discharge Totals 300 250 200 0
0 c
150 0
100 50 0
Jan Feb Mar Apr May Jun Jul Aug Sep Oct Nov Dec
-'20091 2-11
TABLE 2-5 ESTIMATED TOTAL ERRORS ASSOCIATED WITH EFFLUENTS MEASUREMENTS ESTIMATED MEASUREMENT TOTAL ERROR
- 1.
Airborne Effluents
- a.
Fission and Activation Gases 15.9%
- b.
1-131 13.3%
- c.
Particulates (incl. Gross Alpha) 15.8%
- d.
Tritium 13.6%
- 2.
Waterborne Effluents
- a.
Fission and Activation Products 5.0%
- b.
Tritium 3.3%
- c.
Dissolved and Entrained Gases 8.4%
- d.
Gross Alpha Activity 6.0%
- e.
Volume of Waste Released 5.0%
(Prior to Dilution)
- f.
Volume of Dilution Water Used During Period 15.0%
ESTIMATED MAXIMUM MEASUREMENT ERROR
- 3.
Solid Wastes
- a.
CFS Backwash Media -
+/-25%
Class A HIC (Pyrolysis)
- b.
CFS Filters-Class A HIC (Pyrolysis)
+/-25%
- c.
Condensate Demineralizer / Radwaste Demineralizer -
+/-25%
Class A HIC (Pyrolysis)
- d.
Liquid Radwaste Filter Media - Class A HIC
+/-25%
(Pyrolysis)
- e.
+/-25%
(Compacted)
- f.
Processed DAW - Class A Strong Tight Container
+/-25%
(Compacted)
- g.
Sump Sludge - Class A HIC (Prolysis)
+/-25%
2-12
SUSQUEHANNA STEAM ELECTRIC STATION RADIOACTIVE WASTE REPORT RADIOACTIVE EFFLUENT RELEASE REPORT SOLID RADIOACTIVE WASTE DATA PERIOD:
JANUARY 1, 2009 - DECEMBER 31, 2009 PREPARED BY:
APPROVED BY:
MICHAEL C. MICCA HEALTH PHYSICIST R*ICK KESSLER RADIOLOGICAL OPERATIONS SUPERVISOR 2-13
REPORT NOTES
- 1.
All activities reported in Milli-Curies (mCi) unless otherwise noted.
- 2.
Reported activities, as indicated with the (<) sign, are comprised in whole or part of MDL values.
- 3.
Estimated maximum measurement error is +/-25%.
2-14
TABLE 2-6 WASTE DISPOSITION Data Period: January 1, 2009 - December 31, 2009 A.
SOLID WASTE SHIPPED OFF-SITE FOR BURIAL OR DISPOSAL Number of Shipments Mode of Transportation Destination NONE B.
IRRADIATED FUEL SHIPMENTS Number of Shipments Mode of Transportation Destination NONE NOTE: The number of shipments listed in A include only the shipments from PPL Susquehanna, LLC to a disposal site. It does not include shipments made to or from volume reduction vendors.
2-15
Table 2-7 Annual Waste Release Summary Report Year: 2009 Class: A Volume Reduction Vendor:
Source: CFS Backwash Media Container: HIC (High Integrity Container)
Process: Pyrolysis Yes Nuclides Activity (mCi)
C-14 1.860E+01 CO-58 1.973E+01 CO-60 7.265E+03 CS-137 7.704E+00 FE-55 8.344E+03 H-3 9.958E+01 1-129
< 4.760E-02 MNq-54 1.285E+03 NI-59 5.024E-01 NI-63 8.383E+01 SR-90 5.119E-02 TC-99
< 4.940E-01 ZN-65 2.179E+02 Total Activity (Ci) 17.343 Container Volume 43.980 ft3
% of Total 0.11 %
0.11 %
41.89 %
0.04 %
48.11 %
0.57 %
0.00 %
7.41 %
0.00 %
0.48 %
0.00 %
0.00 %
1.26 %
100.00 %
1.245 m3 2-16
Table 2-8 Annual Waste Release Summary Report Class: A Container:
Year: 2009 Volume Reduction Vendor:
Source: CFS Filters HIC (High Integrity Container)
Process: Pyrolysis Yes Nuclides Activity (mCi)
C-14 1.251E+00 CO-57 2.127E-01 CO-58 6.587E+00 CO-60 2.787E+03 CR-51 1.701E+00 CS-137 3.418E+00 FE-55 8.903E+03 FE-59 1.033E+00 H-3 4.032E+01 1-129
< 1.950E-03 MN-54 5.883E+02 NB-95 7;898E-01 NI-59 1.892E-01 NI-63 4.318E+01 SR-89 1.507E-01 SR-90 4.009E-02 TC-99
< 2.030E-02 ZN-65 1.393E+02 Total Activity (Ci) 12.517 Container Volume 142.040 ft3
% of Total 0.01 %
0.00 %
0.05 %
22.27 %
0.01 %
0.03 %
71.13 %
0.01 %
0.32 %
0.00 %
4.70 %
0.01 %
0.00 %
0.35 %
0.00 %
0.00 %
0.00 %
1.11 %
100.00 %
4.022 m3 2-17
Table 2-9 Annual Waste Release Summary Report Class: A Source: Condensate Container:
Year: 2009 Volume Reduction Vendor: Yes Demineralizer / Radwaste Demineralizer HIC (High Integrity Container)
Process: Pyrolysis Nuclides Activity (mCi)
% of Total C-14 CE-144 CM-242 CO-58 CO-60 CR-51 CS-137 FE-55 FE-59 H-3 HF-181 1-129 MN-54 NB-95 NI-63 PU-238 PU-239 PU-241 SB-124 SB-125 SR-90 TA-182 TC-99 ZN-65 ZR-95
- 1. 272E+03 2.518E-01
- 2. 560E-03 5. 850E+01 2. 408E+03
- 3. 469E+01
- 8. 157E+00
- 3. 179E+02 2 294E+01
- 5. 331E+02 7 900E+00 S4. 600E-02 5 234E+02 2 524E+01 9 307E+01
- 3. 145E-01
- 7. 180E-02
- 9. 014E-01
- 1. 561E+00
- 6. 290E+00
- 1. 691E-01 7.910E+00
< 5.180E-01
- 1. 101E+02 3.009E+01 5.463 225.290 ft3 23.29 0.00 0.00 1.07 44.07 0.64 0.15 5.82 0.42 9.76 0.14 0.00 9.58 0.46 1.70 0.01 0.00 0.02 0.03 0.12 0.00 0.14 0.01 2.01 0.55 Total Activity (Ci)
Container Volume 100.00 %
6.380 m3 2-18
Table 2-10 Annual Waste Release Summary Report Class: A Source:
Container:
Year: 2009 Volume Reduction Vendor:
Yes Liquid Radwaste Filter Media HIC (High Integrity Container)
Process: Pyrolysis Nuclides Activity (mCi)
C-14 2.563E-01 CO-58 1.317E+02 CO-60 4.437E+03 CR-51 2.028E+01 CS-137 4.868E-01 FE-55 1.602E+04 FE-59 1.833E+01 H-3 1.144E+00 1-129
< 5.550E-02 MN-54 1.328E+03 NI-63 7.721E+01 SR-90 3.488E-02 TC-99
< 5.200E-01 ZN-65 2.543E+02 Total Activity (Ci) 22.285 Container Volume 74.400 ft3
% of Total 0.00 %
0.59 %
19.91 %
0.09 %
0.00 %
71.87 %
0.08 %
0.01 %
0.00 %
5.96 %
0.35 %
0.00 %
0.00 %
1.14 %
100.00 %
2.107 m3 2-19
Table 2-11 Annual Waste Release Summary Report Year: 2009 Class: A Volume Reduction Vendor: Yes Source: Processed DAW Container: HIC (High Integrity Container)
Process: Compacted Nuclides C-14 CE-144 CM-242 CO-58 CO-60 CS-137 FE-55 H-3 MN-54 NI-63 PU-238 PU-241 SR-90 ZN-65 Activity (mCi)
- 4. 550E+00
- 3. 960E-02
- 3. 090E-04
- 3. 120E-01
- 2. 660E+01
- 2. 750E-01
- 1. 960E+00
- 1. 680E+01
- 2. 440E+00
- 3. 550E-01
- 8. 650E-02
- 1. 990E-01
- 3. 760E-02
- 4. 370E+00
% of Total 7.84 %
0.07 %
0.00 %
0.54 %
45.84 %
0.47 %
3.38 %
28.95 %
4.21 %
0.61 %
0.15 %
0.34 %
0.06 %
7.53 %
100.00 %
1.093 m3 Total Activity (Ci)
Container Volume 0.058 38.600 ft3 2-20
Table 2-12 Annual Waste Release Summary Report Year: 2009 Class: A Volume Reduction Vendor: Yes Source: Processed DAW Container: Strong Tight Container Process: Compacted Nuclides C-14 CO-58 CO-60 CR-51 CS-137 FE-55 FE-59 H-3 MN-54 NB-95 NI-59 NI-63 SB-124 SR-89 SR-90 TA-182 ZN-65 ZR-95 Total Activity Container Volume Activity (mCi) 1.830E+01 2.702E+00 5.611E+02 7.580E-02 4.568E-01 1.205E+03 1.163E-01 8.180E+01 9.172E+01
- 3. 520E+00
- 2. 336E-05
- 1. 051E+01
- 1. 040E-04
- 2. 400E-03
- 9. 109E-04
- 6. 625E-04
- 9. 711E+00
- 1. 134E-04 (Ci) 1.985 5469.158 ft3
% of Total 0.92 %
0.14 %
28.27 %
0.00 %
0.02 %
60.70 %
0.01 %
4.12 %
4.62 %
0.18 %
0.00%
0.53%
0.00 %
0.00 %
0.00 %
0.00 %
0.49 %
0.00 %
100.00 %
154.872 m3 2-21
Table 2-13 Annual Waste Release Summary Report Clas Year: 2009 ss: A Volume Reduction Vendor:
Source: Sump Sludge Container: HIC (High Integrity Container)
Process: Pyrolysis Yes Nuclides Activity (mCi)
C-14 6.785E+01 CO-58 8.331E+00 CO-60 1.898E+03 CR-51 4.625E-01 CS-137 2.489E-01 FE-55 3.692E+03 FE-59 1.761E+00 H-3 3.760E+00 1-129
< 2.260E-02 MN-54 4.957E+02 NB-95 3.771E-01 NI-63 7.158E+01 SB-124 3.198E-01 SR-89 4.586E-02 SR-90 4.091E-02 TC-99
< 2.160E-01 ZN-65 5.781E+01 ZR-95 1.194E+00 Total Activity (Ci) 6.300 Container Volume 27.580 ft3
% of Total 1.08 %
0.13 %
30.13 %
0.01 %
0.00 %
58.61 %
0.03 %
0.06 %
0.00 %
7.87 %
0.01 %
1.14 %
0.01 %
0.00 %
0.00 %
0.00 %
0.92 %
0.02 %
100.00 %
0.781 m3 2-22
SECTION 3 METEOROLOGICAL DATA AND DISPERSION ESTIMATES 3-1
METEOROLOGY AND DISPERSION DATA Meteorological data have been collected at the PPL Susquehanna, LLC site since the early 1970s. At the present time, the meteorological system is based on a 300-foot high tower located approximately 1,000 feet to the southeast of the plant. Wind sensors are mounted at the 10m and 60m elevations on this tower. Vertical temperature differential is measured with redundant sensor pairs between the 10m and 60m levels.
Sigma theta (the standard deviation of horizontal wind direction) is calculated from wind direction at both levels. Dew point and ambient temperature sensors are present at the 1 Om level. Precipitation is measured at ground level.
A back-up meteorological tower was erected in 1982.
It is a 10m tower providing alternate measurements of wind speed, wind direction, and sigma theta.
A 10m supplemental downriver meteorological tower is also available. This tower measures wind speed, wind direction, sigma theta, temperature and dew point.
Meteorological data are transmitted to the plant Control Room, Technical Support Center, Emergency Operations Facility for emergency response availability, and ABSG Consulting, Inc.
ABSG Consulting, Inc., located in Rockville, Maryland, provides meteorological consulting services to PPL Susquehanna, LLC.
Regulatory Guide 1.23 (Safety Guide 23) requires at least 90% data recovery for meteorological instrumentation. During 2009, all meteorological instrumentation met the 90% data recovery requirement. Table 3-1 lists the percent valid data recovery values for the parameters monitored as part of the PPL Susquehanna Meteorological Monitoring Program.
Dispersion modeling for effluents from normal operation is done using the MIDAS system XDCALC program, a straight-line Gaussian plume model designed to estimate average relative concentration.
The model was developed in accordance with Regulatory Guide 1.111. For periods when the wind speed is calm, the actual wind direction that last occurred is used.
XDCALC and the XQINTR program that interpolates X/Q values to exact locations both use terrain correction factors to account for the temporal and spatial variations in the airflow in the region.
A straight-line trajectory model assumes that a constant mean wind transports and diffuses effluents in the direction of airflow at the release point within the entire region of interest. The terrain correction factors were taken from FSAR Table 2.3-128.
Tables 3-2 and 3-3 provide the joint frequency distribution of wind speed and direction (as a function of delta temperature) at the 10 and 60 meter elevations of the primary meteorological tower.
Table 3-4 lists no decay, undepleted X/Q values at various distances from the site. Table 3-5 lists 2.26 day decay, undepleted X/Q values at various distances from the site. Table 3-6 lists 8-day decay, depleted X/Q values at various distances from the site and Table 3-7 is a listing of D/Q (relative deposition) values at various distances from the site.
3-2
TABLE 3-1 METEOROLOGICAL DATA RECOVERY FOR 2009 Parameter Percent Valid Data Recovery Wind Speed 10m - Primary (1)995 Wind Speed 60m - Primary 99.0 Wind Speed 10m - Backup (2) 99.6 Wind Speed 10m - Downriver (3) 100.0 Wind Direction 10m - Primary 98.8 Wind Direction 60m - Primary 99.4 Wind Direction 1Gm -Backup 99.8 Wind Direction 1Gm - Downriver 100.0 Temperature 1Gm - Primary 99.6 Dew Point 1Gm - Primary 98.9 Delta Temperature 60m - Primary 98.7 Sigma Theta 1Gm - Primary 98.8 Sigma Theta 60m - Primary 99.4 Sigma Theta 1Gm - Backup 99.8 Sigma Theta 1Gm - Downriver 100.0 Precipitation - Primary 100.0 Composite Parameters Wind Speed and Direction 1Gm, 98.0 Delta Temperature 60-1Gm Wind Speed and Direction 60m, 98.5 Delta Temperature 60-1 Gm (1)
SSES "Primary" meteorological tower (2)
SSES "Backup" meteorological tower (3)
SSES "Downriver" meteorological tower 3-3
TABLE 3-2 SSES JOINT FREQUENCY DISTRIBUTION OF WIND SPEED AND WIND DIRECTION 10m VERSUS DELTA TEMPERATURE 60-10m FOR THE PERIOD OF JANUARY 1, 2009 THROUGH DECEMBER 31, 2009 Joint Frequency Distribution Hours at Each Wind Speed and Direction Total Period Period of Record =
1/1/2009 00:00 12/31/2009 23:00 Elevation:
Speed:
lOM_SPD Direction: IOM_WD Lapse: DT60-10A Stability Class A Delta Temperature Extremely Unstable Wind Speed (m/s)
Wind Direction 0.23 - 0.51 - 0.76 -
1.1 -
1.6-2.1-3.1-5.1-7.1-10.1-13.1-(from) 0.50 0.75 1.0 1.5 2.0 3.0 5.0 7.0 10.0 13.0 18.0 > 18.0 Total N
0 0
0 1
1 6
2 0
0 0
0 0
10 NNE 0
0 0
0 0
4 9
0 0
0 0
0 13 NE 0
0 0
0 2
5 3
0 0
0 0
0 10 ENE 0
0 0
1 3
0 0
0 0
0 0
0 4
E 0
0 0
2 2
0 0
0 0
0 0
0 4
ESE 0
0 0
2 1
0 0
0 0
0 0
0 3
SE 0
0 0
0 1
0 1
0 0
0 0
0 2
SSE 0
0 0
1 1
2 1
0 0
0 0
0 5
S 0
0 0
2 3
5 2
0 0
0 0
0 12 SSW 0
0 0
3 5
11 15 0
0 0
0 0
34 SW 0
0 0
0 1
17 48 10 0
0 0
0 76 WSW 0
0 0
2 0
4 10 4
0 0
0 0
20 W
0 0
0 1
1 1
3 1
0 0
0 0
7 WNW 0
0 0
0 0
0 2
0 0
0 0
0 2
NW 0
0 0
1 0
0 0
0 0
0 0
0 1
NNW 0
0 0
0 0
0 0
0 0
0 0
0 0
Totals 0
0 0
16 21 55 96 15 0
0 0
0 203 Number of Calm Hours not included above for:
Total Period 0
Number of Variable Direction Hours for:
Total Period 0
Number of Invalid Hours for:
Total Period 171 Number of Valid Hours for:
Total Period 203 Total Hours for:
Total Period 8760 3-4
TABLE 3-2 (continued)
SSES JOINT FREQUENCY DISTRIBUTION OF WIND SPEED AND WIND DIRECTION 10m VERSUS DELTA TEMPERATURE 60-10m FOR THE PERIOD OF JANUARY 1, 2009 THROUGH DECEMBER 31, 2009 (Continued)
Joint Frequency Distribution Hours at Each Wind Speed and Direction Total Period Period of Record =
1/1/2009 00:00 12/31/2009 23:00 Elevation:
Speed: l0M_SPD Direction: 10M_WD Lapse: DT60-10A Stability Class B Delta Temperature Moderately Unstable Wind Speed (m/s)
Wind Direction 0.23 - 0.51 - 0.76 -
1.1 -
1.6-2.1-3.1-5.1-7.1-10.1-13.1-(from) 0.50 0.75 1.0 1.5 2.0 3.0 5.0 7.0 10.0 13.0 18.0 > 18.0 Total N
0 0
0 0
- 1.
0 2
0 0
0 0
0 3
NNE 0
0 0.0 0
10 13 0
0 0
0 0
23 NE 0
0 0
1 2
4 2
0 0
0 0
0 9
ENE 0
0 0
0 1
4 1
0 0
0 0
0 6
E 0
0 1
1 1
1 0
0 0
0 0
0 4
ESE 0
0 0
0 0
1 0
0 0
0 0
0 1
SE 0
0 0
0 1
0 0
0 0
0 0
0 1
SSE 0
0 0
0 1
0 3
.0 0
0 0
0 4
S 0ý 0
0 0
1 2
5 0
0 0
0 0
8 SSW 0
0 0
1 2
10 1
0 0
0 0
0 14 SW 0
0 0
0 2
20 45 3
0 0
0 0
70 WSW 0
0 0
0 0
3 28 8
0 0
0 0
39 W
0 0
0 0
- 0.
1 1
0 0
0 0
0 2
WNW 0
0 0
0 0
0 3
0 0
0 0
0 3
NW 0
0 0
0 0
0 0
0 0
0 0
0 0
NNW 0
0 0
0 0
0 3
3 0
0 0
0 6
Totals 0
0 1
3 12 56 107 14 0
0 0
0 193 Number of Calm Hours not included above for:
Total Period 0
Number of Variable Direction Hours for:
Total Period 0
- Number of Invalid Hours for:
Total Period 171 Number of Valid Hours for:
Total Period 193 Total Hours for:
Total Period 8760 3-5
TABLE 3-2 (continued)
SSES JOINT FREQUENCY DISTRIBUTION OF WIND SPEED AND WIND DIRECTION 10m VERSUS DELTA TEMPERATURE 60-10m FOR THE PERIOD OF JANUARY 1, 2009 THROUGH DECEMBER 31, 2009 (Continued)
Joint Frequency Distribution Hours at Each Wind Speed and Direction Total Period Period of Record =
1/1/2009 00:00 12/31/2009 23:00 Elevation:
Speed: l0M_SPD Direction: 10MWD Lapse: DT60- I OA Stability Class C Delta Temperature Slightly Unstable Wind Speed (m/s)
Wind Direction 0.23 - 0.51 - 0.76 -
1.1 -
1.6-2.1-3.1-5.1-7.1-10.1-13.1-(from) 0.50 0.75 1.0 1.5 2.0 3.0 5.0 7.0 10.0 13.0 18.0 > 18.0 Total N
0 0
0 0
1 7
15 1
0 0
0 0
24 NNE 0
0 1
0 4
23 31 1
0 0
0 0
60 NE 0
0 0
1 5
17 2
0 0
0 0
0 25 ENE 0
0 1
2 6
2 0
0 0
0 0
0 11 E
0 0
0 4
2 4
1 0
0 0
0 0
11 ESE 0
0 1
1 2
1 1
0 0
0 0
0 6
SE 0
0 0
1 1
10 3
0 0
0 0
0 15 SSE 0
0 0
1 0
1 5
0 0
0 0
0 7
S 0
0
- 0.
1 3
5 6
0 0
0 0
0 15 SSW 0
0 0
2 7
20 11 1
0 0
0 0
41 SW 0
0 0
1 2
31 46 3
0 0
0 0
83 WSW 0
0 0
1 1
4 50 12 2
0 0
0 70 W
0 0
0 0
1 1
18 1
0 0
0 0
21 WNW 0
0 0
0 0
0 7
0 0
6 0
0 7
NW 0
0 0
0 0
0 0
1 0
0 0
0 1
NNW 0
0 0
0 2
0 6
5 0
0 0
0 13 Totals 0
0 3
15 37 126 202 25 2
0 0
0 410 Number of Calm Hours not included above for:
Total Period 0
Number of Variable Direction Hours for:
Total Period 0
Number of Invalid Hours for:
Total Period 171 Number of Valid Hours for:
Total Period 410 Total Hours for:
Total Period 8760 3-6
TABLE 3-2 (continued)
SSES JOINT FREQUENCY DISTRIBUTION OF WIND SPEED AND WIND DIRECTION 10m VERSUS DELTA TEMPERATURE 60-10m FOR THE PERIOD OF JANUARY 1, 2009 THROUGH DECEMBER 31, 2009 (Continued)
Joint Frequency Distribution Hours at Each Wind Speed and Direction Total Period Period of Record =
1/1/2009 00:00 12/31/2009 23:00 Elevation:
Speed: 1 OMSPD Direction: I OM_WD Lapse: DT60-10A Stability Class D Delta Temperature Neutral Wind Speed (mis)
Wind Direction 0.23 - 0.51 - 0.76 -
1.1 -
1.6-2.1-. 3.1-5.1-7.1-10.1-13.1-(from) 0.50 0.75 1.0 1.5 2.0 3.0 5.0 7.0 10.0 13.0 18.0 > 18.0 Total N
1 1
6 22 23 105 144 18 0
0 0
0 320 NNE 0
4 16 59 63 157 91 15 0
0 0
0, 405 NE 0
2 25 65 77 173 65 0
0 0
0 0
407 ENE 0
9 33 48 41 36 20 0
0 0
0 0
187 E
0 10 28 47 17 28 26 4
0 0
0 0
160 ESE 2
6 23 40 18 28 25 3
1 0
0 0
146 SE 2
9 22 35 40 47 29 3
0 0
0 0
187 SSE 0
3 19 42 34 51 28 1
0 0
0 0
178 S
0
- 2.
10 59 43 87 66 3
0 0
0 0
270 SSW 0
2 3
39 53 70 38 1
0 0
0 0
206 SW 0
0 5
22 43 93 135 30 0
0 0
0 328 WSW 0
1 5
13 34 61 145
.95 44 1
0 0
399 W
0 0
1 2
19 38 102 61 19 0
0 0
242 WNW 0
0 0
4 10 23 48 26 0
0 0
0 111 NW 0
1 0
2 9
38 74 39 7
- 0 0
0 170 NNW 0
0 3
9 14 52 181 48 5
0 0
0 312 Totals 5
50 199 508 538 1087 1217 347 76 1
0 0
4028 Number of Calm Hours not included above for:
Total Period 0
Number of Variable Direction Hours for:
Total Period 0
Number of Invalid Hours for:
Total Period 171 Number of Valid Hours for:
Total Period 4028 Total Hours for:
Total Period 8760 3-7
TABLE 3-2 (continued)
SSES JOINT FREQUENCY DISTRIBUTION OF WIND SPEED AND WIND DIRECTION 10m VERSUS DELTA TEMPERATURE 60-10m FOR THE PERIOD OF JANUARY 1, 2009 THROUGH DECEMBER 31, 2009 (Continued)
Joint Frequency Distribution Hours at Each Wind Speed and Direction Total Period Period of Record =
1/1/2009 00:00 12/31/2009 23:00 Elevation:
Speed: l0M_SPD Direction: 10M_WD Lapse: DT60-10A Stability Class E Delta Temperature Slightly Stable Wind Speed (m/s)
Wind Direction 0.23 - 0.51 - 0.76 - 1.1 -
1.6-2.1-3.1-5.1-7.1-10.1-13.1-(from) 0.50 0.75 1.0 1.5 2.0 3.0 5.0 7.0 10.0 13.0 18.0 > 18.0 Total N
0 1
5 25 32 29 12 0
0 0
0 0
104 NNE 0
2 19 69 64 69 1
0 0
0 0
0 224 NE 1
11 71 126 73 27 0
0 0
0 0
0 309 ENE 2
36 118 141 17 4
6 0
0 0
0 0
324 E
5 48 98 39 5
8 2
0 0
0 0
0 205 ESE 0
40 64 23 11 2
1 0
0 0
0 0
141 SE 1
33 53 44 4
10 2
1 0
0 0
0-148 SSE 3
11 31 44 22 16 5
0 0
0 0
0 132 S
1 9
30 77 37 34 14 4
0 0
0 0
206 SSW 0
1 14 63 62 51 19 1
0 0
0 0
211 SW 1
1 3
24 46 66 24 2
0 0
0 0
167 WSW 0
0 5
11 9
16 23 0
0 0
0 0
64 W
0 0
0 6
6 8
1 0
0 0
0 0
21 WNW 0
0 2
2 8
6 1
0 0
0 0
0 19 NW 0
0
- 3.
1 6
9 4
0 0
0 0
0 23 NNW 0
3 2
4 6
24 6
0 0
0 0
0 45 Totals 14 196 518 699 408 379 121 8
0 0
0 0
2343 Number of Calm Hours not included above for:
Total Period 0
Number of Variable Direction Hours for:
Total Period 0
Number of Invalid Hours for:
Total Period 171 Number of Valid Hours for:
Total Period 2343 Total Hours for:
Total Period 8760 3-8
TABLE 3-2 (continued)
SSES JOINT FREQUENCY DISTRIBUTION OF WIND SPEED AND WIND DIRECTION 10m VERSUS DELTA TEMPERATURE 60-10m FOR THE PERIOD OF JANUARY 1, 2009 THROUGH DECEMBER 31, 2009 (Continued)
Joint Frequency Distribution Hours at Each Wind Speed and Direction Total Period Period of Record =
1/1/2009 00:00 12/31/2009 23:00 Elevation:
Speed:
IOM_SPD Direction: IOM_WD Lapse: DT60-10A Stability Class F Delta Temperature Moderately Stable Wind Speed (m/s)
Wind Direction 0.23 - 0.51 - 0.76 - 1.1 -
1.6-2.1-3.1-5.1-7.1-10.1-13.1-(from) 0.50 0.75 1.0 1.5 2.0 3.0 5.0 7.0 10.0 13.0 18.0 > 18.0 Total N
0 0
3 3
2 3
0 0
0 0
0 0
11 NNE 1
2 6
14 3
3 1
0 0
0 0
0 30 NE 0
14 41 50 10 4
2 0
0 0
0 0
121 ENE 1
41 149 174 19 1
0 0
0 0
0 0
385 E
4 50 85 28 1
0 0
0 0
0 0
0 168 ESE 1
22 20 5
1 0
0 0
0 0
0 0
49 SE 1
13 21 1
0 0
0 0
0 0
0 0
36 SSE 3
1 10 13 0
0 0
0 0
0 0
0 27 S
0 3
10 22 0
0 0
0 0
0 0
0 35 SSW 0
2 1
12 2
1 0
0 0
0 0
0 18 SW 0
1 0
3 1
1 1
0 0
0 0
0 7
WSW 0
0 0
2 0
0 0
0 0
0 0
0 2
W 0
0 0
1 0
0 0
0 0
0 0
0 1
WNW 0
0 0
0 0
0 0
0 0
0 0
0 0
NW 0
0 1
0 0
0 0
0 0
0 0
0 1
NNW 0
0 2
0 0
1 0
0 0
0 0
0 3
Totals 1I 149 349 328 39 14 4
0 0
0 0
0 894 Number of Calm Hours not included above for:
Total Period 0
Number of Variable Direction Hours for:
Total Period 0
Number of Invalid Hours for:
Total Period 171 Number of Valid Hours for:
Total Period 894 Total Hours for:
Total Period 8760 3-9
TABLE 3-2 (continued)
SSES JOINT FREQUENCY DISTRIBUTION OF WIND SPEED AND WIND DIRECTION 10m VERSUS DELTA TEMPERATURE 60-10m FOR THE PERIOD OF JANUARY 1, 2009 THROUGH DECEMBER 31, 2009 (Continued)
Joint Frequency Distribution Hours at Each Wind Speed and Direction Total Period Period of Record -
1/1/2009 00:00 12/31/2009 23:00 Elevation:
Speed: l0M_SPD Direction: 10M_WD Lapse: DT60-1OA Stability Class G Delta Temperature Extremely Stable Wind Speed (m/s)
Wind Direction 0.23 - 0.51 - 0.76 - 1.1 -
1.6-2.1-3.1-5.1-7.1-10.1-13.1-fom) 0.50 0.75 1.0 1.5 2.0 3.0 5.0 7.0 10.0 13.0 18.0 > 18.0 Total N
0 0
0 0
0 1
0 0
0 0
0 0
1 NNE 0
1 2
3 1
1 0
0 0
0 0
0 8
NE 0
6 37 35 7
2 0
0 0
0 0
0 87 ENE 1
18 102 165 19 2
0 0
0 0
0 0
307 E
1 16 39 16 0
1 0
0 0
0 0
0 73 ESE 0
6 10 2
0 0
0 0
0 0
0 0
18 SE 0
3 4
3 0
0 0
0 0
.0 0
0 10 SSE 0
3 4
3 2
0 0
0 0
0 0
0 12 S
0 0
0 1
0 0
0 0
0 0
0 0
1 SSW 0
0 1
0 0
0 0
0 0
0 0
0 1
SW 0
0 0
0 0
0 0
0 0
0 0
0 0
WSW 0
0 0
0 0
0 0
0 0
0 0
0 0
W 0
0 0
0 0
0 0
0 0
0 0
0 0
WNW 0
0 0
0 0
0 0
0 0
0 0
0 0
NW 0
0 0
0 0
0 0
0 0
0 0
0 0
NNW 0
0 0
0 0
0 0
0 0
0 0
0 0
Totals 2
53 199 228 29 7
0 0
0 0
0 0
518 Number of Calm Hours not included above for:
Total Period 0
Number of Variable Direction Hours for:
Total Period 0
Number of Invalid Hours for:
Total Period 171 Number of Valid Hours for:
Total Period 518 Total Hours for:
Total Period 8760 3-10
TABLE 3-2 (continued)
SSES JOINT FREQUENCY DISTRIBUTION OF WIND SPEED AND WIND DIRECTION 10m VERSUS DELTA TEMPERATURE 60-10m FOR THE PERIOD OF JANUARY 1, 2009 THROUGH DECEMBER 31, 2009 (Continued)
Joint Frequency Distribution Hours at Each Wind Speed and Direction Summary of All Stability Classes Total Period 1/1/2009 00:00 12/31/2009 23:00 Period of Record =
Elevation:
Speed:
10M_SPD Direction: I OM_WD Lapse: DT60-10A Delta Temperature Wind Speed (m/s)
Wind Direction (from)
N NNE NE ENE E
WNW NW NNW 0.23-0.51-0.76-1.1, 1.6-2.1-3.1-5.1-7.1-10.1-13.1-0.50 0.75 1.0 1.5 2.0 3.0 5.0 7.0 10.0 13.0 18.0 > 18.0 Total l
2 14 51 60 151 175 19 0
0 0
0 473 1
9 44 145 135 267 146 16 0
0 0
0 763 1
33 174 278 176 232 74 0
0 0
0 0
968 4
104 403 531 106 49 27 0
0 0
0 0
1224 10 124 251 137 28 42 29 4
0 0
0 0
625 3
74 118 73 33 32 27 3
1 0
0 0
364 4
58 100 84 47 67 35 4
0 0
0 0
399 6
18 64 104 60 70 42 1
0 0
0 0
365 1
14 50 162 87 133 93 7
0 0
0 0
547 0
5 19 120 131 163 84 3
0 0
0 0
525 1
2 8
50 95 228 299 48 0
0 0
0 731 0
1 10 29 44 88 256 119 46 1
0 0
594 0
0 1
10 27 49 125 63 19 0
0 0
294 0
0 2
6 18 29 61 26 0
0 0
0 142 0
1 4
4 15 47 78 40 7
0 0
0 196 0
3 7
13 22 77 196 56 5
0 0
0 379 Totals 32 448 1269 1797 1084 1724 1747 409 78 1
0 0
8589 Number of Calm Hours not included above for:
Number of Variable Direction Hours for:
Number of Invalid Hours for:
Number of Valid Hours for:
Total Hours for:
Total Period Total Period Total Period Total Period Total Period 0
0 171 8589 8760 3-11
TABLE 3-3 SSES JOINT FREQUENCY DISTRIBUTION OF WIND SPEED AND WIND DIRECTION 60m VERSUS DELTA TEMPERATURE 60-10m FOR THE PERIOD OF JANUARY 1, 2009 THROUGH DECEMBER 31, 2009 Joint Frequency Distribution Hours at Each Wind Speed and Direction Period of Record =
1/1/2009 00:00 12/31/2009 23:00 Elevation:
Speed: 60MSPD Direction: 60MWD Lapse: DT60- I OA Stability Class A Delta Temperature Extremely Unstable Wind Speed (mis)
Wind Direction 0.23 - 0.51 - 0.76 -
1.1 -
1.6-2.1-3.1-5.1-7.1-10.1-13.1-(from) 0.50 0.75 1.0 1.5 2.0 3.0 5.0 7.0 10.0 13.0 18.0 > 18.0 Total N
0 0
0 0
1 4
1 2
0 0
0 0
8 NNE 0
0 0
0 1
3 10 6
0 0
0 0
20 NE 0
0 0
2 1
1 2
0 0
0 0
0 6
ENE 0
0 0
2 2
2 0
0 0
0 0
0 6
E 0
0 0
0 0
1 0
0 0
0 0
0 1
ESE 0
0 0
0 1
1 0
0 0
0 0
0 2
SE 0
0 0
0 1
0 0
1 0
0 0
0 2
SSE 0
0 0
1 1
2 0
1 0
0 0
0 5
S 0
0 0
2 2
3 0
1 1
0 0
0 9
SSW 0
0 0
0 5
6 13 9
1 0
0 0
34 SW 0
0 0
0 1
7 31 33 14 0
0 0
86 WSW 0
0 0
1 1
2 2
8 2
0 0
0 16 W
0 0
0 1
0 0
1 4
0 0
0 0
6 WNW 0
0 0
0 0
0 0
0 0
0 0
0 0
NW 0
0 1
0 0
0 0
0 0
0 0
0 1
NNW 0
0 0
0 0
1 0
0 0
0 0
0 1
Totals 0
0 1
9 17 33 60 65 18 0
0 0
203 Number of Calm Hours not included above for:
Total Period 0
Number of VariableDirection Hours for:
Total Period 0
Number of Invalid Hours for:
Total Period 135 Number of Valid Hours for:
Total Period 203 Total Hours for:
Total Period 8760.
3-12
TABLE 3-3 (continued)
SSES JOINT FREQUENCY DISTRIBUTION OF WIND SPEED AND WIND DIRECTION 60m VERSUS DELTA TEMPERATURE 60-10m FOR THE PERIOD OF JANUARY 1, 2009 THROUGH DECEMBER 31, 2009 (Continued)
Joint Frequency Distribution Hours at Each Wind Speed and Direction Total Period Period of Record =
1/1/2009 00:00 12/31/2009 23:00 Elevation:
Speed: 60MSPD Direction: 60MWD Lapse: DT60- I OA Stability Class B Delta Temperature Moderately Unstable Wind Speed (m/s)
Wind Direction 0.23 -
0.51 -
0.76-1.1 -
1.6-2.1 -
3.1 -
5.1 -
7.1 -
10.1 -
13.1 -
(from) 0.50 0.75 1.0 1.5 2.0 3.0 5.0 7.0 10.0 13.0 18.0 > 18.0 Total N
0 0
0 1
0 1
1 4
0 0
0 0
7 NNE 0
0 0
0 2
0 t6 5
0 0
0 0
23 NE 0
0 0
1 1
3 5
1 0
0 0
0 11 ENE 0
0 0
0 1
0 1
0 0
0 0
0 2
E 0
0 0
0 0
0 2
0 0
0 0
0 2
ESE 0
0 0
1 0
0 0
0 0
0 0
0 1
SE 0
0 0
0 0
2 0
0 0
0 0
0 2
SSE 0
0 0
0 0
0 0
3 0
0 0
0 3
S 0
0 0
0 0
0 1
3 1
0 0
0 5
SSW 0
0 0
0 0
5 12 0
0 0
0 0
17 SW 0
0 0
0 0
6 35 25 6
0 0
0 72 WSW 0
0 0
0 0
0 12 17 9
0 0
0 38 W
0 0
0 0
0 0
2 2
0 0
0 0
4 WNW 0
0 0
0 0
0 0
0 0
0 0
0 0
NW 0
0 0
0 0
0 1
0 1
0 0
0 2
NNW 0
0 0
0 0
0 2
2 0
0 0
0 4
Totals 0
0 0
3 4
17 90 62 17 0
0 0
193 Number of Calm Hours not included above for:
Total Period 0
Number of Variable Direction Hours for:
Total Period 0
Number of Invalid Hours for:
Total Period 135 Number of Valid Hours for:
Total Period 193 Total Hours for:
Total Period 8760 3-13
TABLE 3-3 (continued)
SSES JOINT FREQUENCY DISTRIBUTION OF WIND SPEED AND WIND DIRECTION 60m VERSUS DELTA TEMPERATURE 60-10m FOR THE PERIOD OF JANUARY 1, 2009 THROUGH DECEMBER 31, 2009 (Continued)
Joint Frequency Distribution Hours at Each Wind Speed and Direction Period of Record =
1/1/2009 00:00 12/31/2009 23:00 Elevation:
Speed: 60MSPD Direction: 60MWD Lapse: DT60- I 0A Stability Class C Delta Temperature Slightly Unstable Wind Speed (mis)
Wind Direction 0.23 - 0.51 - 0.76 -
1.1 -
1.6-2.1-3.1-5.1-7.1-10.1-13.1-(from) 0.50 0.75 1.0 1.5 2.0 3.0 5.0 7.0 10.0 13.0 18.0> 18.0 Total N
0 0
1 1
0 5
15 7
3 0
0 0
32 NNE 0
0 0
0
- 2 13 40 9
0 0
0 0
64 NE 0
0 0
3 6
6 6
0 1
0 0
0 22 ENE 0
0 0
0 1
4 1
- 0.
0 0
0
- 0.
6 E
0 0
1 2
1 1
2 1
0 0
0 0
8 ESE 0
0 0
0 0
3 4
1 0
0 0
0 8
SE 0
0 0
1 0
1 6
0 0
0 0
0 8
SSE 0
0 0
0 1
2 2
3 0
0 0
0 8
S 0
0 0
0 1
2 2
7 1
0 0
0 13 SSW 0
0 0
1 4
11 13 6
0 1
0 0
36 SW 0
0 0
1 3
5 54 34 2
0 0
0 99 WSW 0
0 0
0 0
0 18 36 12 2
0 0
68 W
0 0
0 0
1 0
9 9
0 0
0 0
19 WNW 0
0 0
0 0
0 0
0 0
0 0
0 0
NW 0
0 0
0 0
0 1
1 4
0 0
0 6
NNW 0
0 0
0 2
0 5
4 1
0 0
0 12 Totals 0
0 2
9 22 53 178 118 24 3
0 0
409 Number of Calm Hours not included above for:
Total Period 0
Number of Variable Direction Hours for:
Total Period 0
Number of Invalid Hours for:
Total Period 135 Number of.Valid Hours for:
Total Period 409 Total Hours for:
Total Period 8760 3-14
TABLE 3-3 (continued)
SSES JOINT FREQUENCY DISTRIBUTION OF WIND SPEED AND WIND DIRECTION 60m VERSUS DELTA TEMPERATURE 60-10m FOR THE PERIOD OF JANUARY 1, 2009 THROUGH DECEMBER 31, 2009 (Continued)
Joint Frequency Distribution Hours at Each Wind Speed and Direction Period of Record =
1/1/2009 00:00 12/31/2009 23:00 Elevation:
Speed: 60MSPD Direction: 60MWD Lapse: DT60-10A Stability Class D Delta Temperature Neutral Wind Speed (m/s)
Wind Direction 0.23 - 0.51 - 0.76 -
1.1 -
1.6-2.1-3.1-5.1-7.1-10.1-13.1-(from) 0.50 0.75 1.0 1.5 2.0 3.0 5.0 7.0 10.0 13.0 18.0 > 18.0 Total N
1 0
4 17 24 42 108 40 12 0
0 0
248 NNE 0
9 5
31
- 46.
95 235 131 31 0
0 0
583 NE 0
1 13 50 33 67 88 9
4 1
0 0
266 ENE 2
3 15 23 24 27 25 20 1
0 0
0 140 E
1 2
8 16 13 20 47 15 18 1
0 0
141 ESE 0
2 9
7 10 19 25 16 5
0 0
0 93 SE 0
1 7
19 13 41 58 20 6
0 0
0 165 SSE 0
3 13 16 13 25 42 13 3
0 0
0 128 S
1 0
8 25 31 21 66 57 13 2
0 0
224 SSW 0
0 3
25 45 64 57 32 13 0
0 0
239 SW 0
2 2
11 39 72 154 85 34 0
0 0
399 WSW 0
0 1
3 12 23 124 142 131 52 6
0 494 W
0 0
1 7
8 21 78 88 44 8
0 0
255 WNW 0
0 0
1 2
11 47 41 26 3
0 0
131 NW 0
0 2
2 4
17 93 103 23 1
0 0
245 NNW 0
0 2
7 8
15 133 87 21 0
0 0
273 Totals 5
23 93 260 325 580 1380 899 385 68 6
0 4024 Number of Calm Hours not included above for:
Total Period 0
Number of Variable Direction Hours for:
Total Period 0
Number of Invalid Hours for:
Total Period 135 Number of Valid Hours for:
Total Period 4024 Total Hours for:
Total Period 8760 3-15
TABLE 3-3 (continued)
SSES JOINT FREQUENCY DISTRIBUTION OF WIND SPEED AND WIND DIRECTION 60m VERSUS DELTA TEMPERATURE 60-10in FOR THE PERIOD OF JANUARY 1, 2009 THROUGH DECEMBER 31, 2009 (Continued)
Joint Frequency Distribution Hours at Each Wind Speed and Direction Period of Record--
1/1/2009 00:00 12/31/2009 23:00 Elevation:
Speed: 60M-SPD Direction: 60MWD Lapse: DT60-10A Stability Class E Delta Temperature Slightly Stable Wind Speed (m/s)
Wind Direction 0.23 - 0.51 - 0.76-1.1-1.6-2.1-3.1-5.1-7.1-10.1-13.1-(from) 0.50 0.75 1.0 1.5 2.0 3.0 5.0 7.0 10.0 13.0 18.0 > 18.0 Total N
0 3
8 21 43 57 49 3
0 0
0 0
184 NNE 1
3 9
59 112 161 97 12 0
0 0
0 454 NE 1
9 22 63 45 56 39 2
0 0
0 0
237 ENE 1
5 24 30 17 19 14 4
0 0
0 0
114 E
1 5
27 17 11 19 13 2
0 0
0 0
95 ESE 0
10 15 12 11 16 12 3
0 0
0 0
79 SE 1
6 16 26 6
12 18 2
2 0
0 0
89 SSE 2
6 14 30 13 19 23 5
1 0
0 0
113 S
0 3
10 25 20 24 45 20 3
5 0
.0 155 SSW 0
5 7
32 34 49 73 29 7
0 0
0 236 SW, 0
2 5
17 22 71 116 36 6
0 0
0 275 WSW 0
0 0
8 13 22 63 60 8
0 0
0 174 W
0 0
0 5
4 17 11 2
0 0
0 0
39 WNW 0
0 1
1 2
6 12 2
0 0
0 0
24 NW 0
0 2
5 4
12 34 5
0 0
0 0
62 NNW 0
0 3
4 6
8 22 4
0 0
0 0
47 Totals 7
57 163 355 363 568 641 191 27 5
0 0
2377 Number of Calm Hours not included above for:
Total Period 0
Number of Variable Direction Hours for:
Total Period 0
Number of Invalid Hours for:
Total Period 135 Number of Valid Hours for:
Total Period 2377 Total Hours for:
Total Period 8760 3-16
TABLE 3-3 (continued)
SSES JOINT FREQUENCY DISTRIBUTION OF WIND SPEED AND WIND DIRECTION 60m VERSUS DELTA TEMPERATURE 60-10m FOR THE PERIOD OF JANUARY 1, 2009 THROUGH DECEMBER 31, 2009 (Continued)
Joint Frequency Distribution Hours at Each Wind Speed and Direction Period of Record -
1/1/2009 00:00 12/31/2009 23:00 Elevation:
Speed: 60MSPD Direction: 60MWD Lapse: DT60- I OA Stability Class F Delta Temperature Moderately Stable Wind Speed (m/s)
Wind Direction 0.23 -
0.51 -
0.76 -
1.1 -
1.6-2.1 -
3.1 -
5.1 -
7.1 -
10.1 -
13.1 -
(from) 0.50 0.75 1.0 1.5 2.0 3.0 5.0 7.0 10.0 13.0 18.0 > 18.0 Total N
0 0
7 7
41 74 14 0
0 0
0 0
143 NNE 1
1 11 51 100 104 14 1
0 0
0 0
283 NE 0
0 23 57 23 7
2 0
0 0
0 0
112 ENE 0
4 18 27 7
0 0
0 0
0 0
0 56 E
1 2
19 16 2
3 1
0 0
0 0
0 44 ESE 0
0 7
9 1
5 0
0 0
0 0
0 22 SE 0
1 3
15 1
0 1
0 0
0 0
0 21 SSE 0
1 3
13 7
3 1
0 0
0 0
0 28 S
0 0
2 10 8
12 3
0 0
0 0
0 35 SSW 0
0 1
12 12 19 13 3
0 0
0 0
60 SW 0
0 2
4 6
13 24 5
0 0
0 0
54 WSW 1
0 0
2 0
4 6
4 0
0 0
0 17 W
0 0
0 3
0 1
0 0
0 0
0 0
4 WNW 0
0 0
0 1
1 2
1 0
0 0
0 5
NW 0
0 1
2 1
0 3
0 0
0 0
0 7
NNW 0
1 1
2 1
5 3
0 0
0 0
0 13 Totals 3
10
- 98 230 211 251 87 14 0
0 0
0 904 Number of Calm Hours not included above for:
Total Period 0
Number of Variable Direction Hours for:
Total Period 0
Number of Invalid Hours for:
Total Period 135 Number of Valid Hours for:
Total Period 904 Total Hours for:
Total Period 8760 3-17
TABLE 3-3 (continued)
SSES JOINT FREQUENCY DISTRIBUTION OF WIND SPEED AND WIND DIRECTION 60m VERSUS DELTA TEMPERATURE 60-10m FOR THE PERIOD OF JANUARY 1, 2009 THROUGH DECEMBER 31, 2009 (Continued)
Joint Frequency Distribution Hours at Each Wind Speed and Direction Period of Record =
1/1/2009 00:00 12/31/2009 23:00 Elevation:
Speed: 60MSPD Direction: 60MWD Lapse: DT60- IOA Stability Class G Delta Temperature Extremely Stable Wind Speed (m/s)
Wind Direction 0.23 - 0.51 - 0.76 -
1.1 -
1.6-2.1-3.1-5.1-7.1-10.1-13.1-(from) 0.50 0.75 1.0 1.5 2.0 3.0 5.0 7.0 10.0 13.0 18.0 > 18.0 Total N
0 0
0 14 26 40 12 0
0 0
0 0
92 NNE 0
0 6
20 49 59 6
1 0
0 0
0 141 NE 0
0 9
34 15 6
- 1.
0 0
0 0
0 65 ENE 0
1 8
12 5
2 0
0 0
0 0
0 28 E
0 2
4 15 3
8 0
0 0
0 0
0 32 ESE 0
3 7
11 5
1 0
0 0
0 0
0
.27 SE 0
0 3
5 2
2 0
0 0
0 0
0 12 SSE 0
0 3
9 5
2 1
0 0
0 0
0 20 S
0 2
1 4
8 5
2 0
0 0
0
- 0.
22 SSW 0
0 0
5 8
13 14 0
0 0
0 0
40 SW 0
0 0
1 1
11 5
0 0
0 0
0 18 WSW 0
0 0
2 0
2 1
0 0
0 0
0 5
W 0
0 0
1 1
0 0
0 0
0 0
0 2
WNW 0
0 0
0 1
0 0
0 0
0 0
0 1
NW 0
0 1
0 1
1 2
0 0
0 0
0 5
NNW 0
0 0
0 0
1 4
0 0
0 0
0 5
Totals 0
8 42 133 130 153 48 1
0 0
0 0
515 Number of Calm Hours not included above for:
Total Period 0
Number of Variable Direction Hours for:
Total Period 0
Number of Invalid Hours for:
Total Period 135 Number of Valid Hours for:
Total Period 515 Total Hours for:
Total Period 8760 3-18
TABLE 3-3 (continued)
SSES JOINT FREQUENCY DISTRIBUTION OF WIND SPEED AND WIND DIRECTION 60m VERSUS DELTA TEMPERATURE 60-10m FOR THE PERIOD OF JANUARY 1, 2009 THROUGH DECEMBER 31, 2009 (Continued)
Joint Frequency Distribution Hours at Each Wind Speed and Direction Summary of All Stability Classes Total Period Period of Record =
1/1/2009 00:00 12/31/2009 23:00 Elevation:
Speed: 60MSPD Direction: 60MWD Lapse: DT60- I OA Delta Temperature Wind Speed (m/s)
Wind Direction 0.23 - 0.51 - 0.76 -
1.1 -
1.6-2.1-3.1-5.1-7.1-10.1-13.1-(from) 0.50 0.75 1.0 1.5 2.0 3.0 5.0 7.0 10.0 13.0 18.0 > 18.0 Total N
1 3
20 61 135 223 200 56 15 0
0 0
714 NNE 2
13 31 161 312 435 418 165 31 0
0 0
1568 NE 1
10 67 210 124 146 143 12 5
1 0
0 719.
ENE 3
13 65 94 57 54 41 24 1
0 0
0 352 E
3 11 59 66 30 52 65 18 18 1
0 0
323 ESE 0
15 38 40 28 45 41 20 5
0 0
0 232 SE 1
8 29 66 23 58 83 23 8
0 0
0 299 SSE 2
10 33 69 40 53 69 25 4
0 0
0 305 S
1 5
21 66 70 67 119 88 19 7
0 0
463 SSW 0
5 11 75 108 167 195 79 21 1
0 0
662 SW 0
4 9
34 72 185 419 218 62 0
0 0
1003 WSW 1
0 1
16 26 53 226 267 162 54 6
0 812 W
0 0
1 17 14 39 101 105 44 8
0 0
329 WNW 0
0 1
2 6
18 61 44 26 3
0 0
161 NW 0
0 7
9 10 30 134 109 28 1
0 0
328 NNW 0
1 6
13 17 30 169 97 22 0
0 0
355 Totals 15 98 399 999 1072 1655 2484 1350 471 76 6
0 8625 Number of Calm Hours not included above for:
Total Period 0
Number of Variable Direction Hours for:
Total Period 0
Number of Invalid Hours for:
Total Period 135 Number of Valid Hours for:
Total Period 8625 Total Hours for:
Total Period 8760 3-19
TABLE 3-4 2009 SSES Annual Relative Concentrations - No Decay, Undepleted X/Q (sec/m 3)
Miles Direction 0-1 1-2 2-3 3-4 4-5 5-10 10-20 20-30 30-40 40-50 From N
4.40E-06 8.41 E-07 3.47E-07 1.82E-07 1.16E-07 4.27E-08 1.15E-08 5.54E-09 3.46E-09 2.43E-09 NNE 9.02E-06 1.81 E-06 8.02E-07 4.27E-07 2.74E-07 1.01 E-07 2.73E-08 1.33E-08 8.42E-09 5.99E-09 NE 1.81 E-05 3.42E-06 1.55E-06 8.71 E-07 5.75E-07 2.26E-07 6.79E-08 3.40E-08 2.18E-08 1.58E-08 ENE 4.1OE-05 7.67E-06 3.74E-06 2.20E-06 1.47E-06 5.79E-07 1.68E-07 8.13E-08 5.26E-08 3.86E-08 E
1.93E-05 3.55E-06 1.57E-06 8.85E-07 5.91 E-07 2.40E-07 7.57E-08 3.83E-08 2.47E-08 1.80E-08 ESE 1.06E-05 2.09E-06 9.39E-07 5.21 E-07 3.45E-07 1.39E-07 3.83E-08 1.67E-08 1.07E-08 7.75E-09 SE 1.13E-05 2.26E-06 1.03E-06 5.78E-07 3.82E-07 1.55E-07 3.85E-08 1.42E-08 9.03E-09 6.48E-09 SSE
,8.51E-06 1.66E-06 7.33E-07 4.11E-07 2.76E-07 1.19E-07 3.10E-08 1.11E-08 7.04E-09 5.05E-09 S
6.83E-06 1.46E-06 7.05 E-07 4.06E-07 2.77E-07 1.27E-07 3.47E-08 1.1 9E-08 7.53 E-09 5.36E-09 SSW 6.55E-06 1.33E-06 6.06E-07 3.41 E-07 2.26E-07 9.34E-08 2.41 E-08 9.16E-09 5.81 E-09 4.14E-09 SW 5.08E-06 1.02E-06 4.83E-07 2.76E-07 1.85E-07 8.12E-08 2.09E-08 7.03E-09 4.44E-09 3.15E-09 WSW 3.77E-06 7.21 E-07 3.33E-07 1.95E-07 1.33E-07 6.22E-08 1.92E-08 7.14E-09 3.63E-09 1.98E-09 W
1.55E-06 2.92E-07 1.25E-07 6.79E-08 4.42E-08 1.78E-08 4.71E-09 1.88E-09 1.16E-09 8.OOE-10 WNW 9.69E-07 1.79E-07 7.15E-08 3.73E-08 2.38E-08 8.78E-09 2.38E-09 1.12E-09 6.95E-10 4.82E-10 NW 1.41 E-06 2.64E-07 1.06E-07 5.38E-08 3.41 E-08 1.23E-08 3.25E-09 1.53E-09 9.44E-10 6.53E-10 NNW 2.79E-06 5.28E-07 2.22E-07 1.18E-07 7.41 E-08 2.57E-08 6.36E-09 3.01 E-09 1.86E-09 1.29E-09 3-20
TABLE 3-5 2009 SSES Annual Relative Concentrations - 2.26-Day Decay, Undepleted X/Q (sec/m3)
Miles Direction 0-1 1-2 2-3 3-4 4-5 5-10 10-20 20-30 30-40 40-50 From N
4.40E-06 8.36E-07 3.44E-07 1.80E-07 1.14E-07 4.16E-08 1.09E-08 5.07E-09 3.06E-09 2.08E-09 NNE 9.OOE-06 1.80E-06 7.94E-07 4.20E-07 2.69E-07 9.76E-08 2.56E-08 1.19E-08 7.22E-09 4.92E-09 NE 1.80E-05 3.40E-06 1.53E-06 8.55E-07 5.62E-07 2.17E-07 6.26E-08 2.96E-08 1.80E-08 1.23E-08 ENE 4.08E-05 7.61E-06 3.68E-06 2.15E-06 1.43E-06 5.54E-07 1.53E-07 7.OOE-08 4.27E-08 2.95E-08 E
1.93E-05 3.51 E-06 1.54E-06 8.63E-07 5.72E-07 2.27E-07 6.80E-08 3.20E-08 1.93E-08 1.31 E-08 ESE 1.06E-05 2.07E-06 9.23E-07 5.08E-07 3.34E-07 1.32E-07 3.44E-08 1.40E-08 8.34E-09 5.60E-09 SE 1.13E-05 2.24E-06 1.01 E-06 5.64E-07 3.71E-07 1.47E-07 3.48E-08 1.20E-08 7.12E-09 4.78E-09 SSE 8.49E-06 1.64E-06 7.22E-07 4.02E-07 2.69E-07 1.13E-07 2.83E-08 9.51 E-09 5.70E-09 3.85E-09 S
6.81 E-06 1.45E-06 6.97E-07 3.99E-07 2.71 E-07 1.23E-07 3.23E-08 1.05E-08 6.34E-09 4.30E-09 SSW 6.54E-06 1.32E-06 6.O0E-07 3.36E-07 2.22E-07 9.05E-08 2.27E-08 8.25E-09 5.02E-09 3.43E-09 SW 5.07E-06 1.02E-06 4.79E-07 2.72E-07 1.82E-07 7.91 E-08 1.99E-08 6.45E-09 3.94E-09 2.70E-09 WSW 3.76E-06 7.18E-07 3.31E-07 1.93E-07 1.31 E-07 6.09E-08 1.84E-08 6.65E-09 3.29E-09 1.74E-09 W
1.55E-06 2.91E-07 1.24E-07 6.73E-08 4.38E-08 1.75E-08 4.55E-09 1.77E-09 1.06E-09 7.15E-10 WNW 9.68E-07 1.78E-07 7.1OE-08 3.69E-08 2.35E-08 8.60E-09 2.28E-09 1.05E-09 6.28E-10 4.23E-10 NW 1.41 E-06 2.63E-07 1.05E-07 5.33E-08 3.37E-08 1.21 E-08 3.11E-09 1.42E-09 8.52E-10 5.72E-10 NNW 2.79E-06 5.26E-07 2.21E-07 1.17E-07 7.31E-08 2.51E-08 6.07E-09 2.78E-09 1.66E-09 1.12E-09 3-21
TABLE 3-6 2009 SSES Annual Relative Concentrations Day Decay, Depleted X/Q (sec/m 3)
Miles Direction Dron 0-1 1-2 2-3 3-4 4-5 5-10 10-20 20-30 30-40 40-50 From N
4.02E-06 7.12E-07 2.81E-07 1.41 E-07 8.71E-08 2.97E-08 7.11E-09 2.98E-09 1.67E-09 1.07E-09 NNE 8.24E-06 1.53E-06 6.48E-07 3.30E-07 2.05E-07 7.O0E-08 1.68E-08 7.13E-09 4.04E-09 2.60E-09 NE 1.65E-05 2.90E-06 1.25E-06 6.74E-07 4.30E-07 1.57E-07 4.16E-08 1.81 E-08 1.03E-08 6.77E-09 ENE 3.74E-05 6.49E-06 3.02E-06 1.70E-06 1.1OE-06 4.01E-07 1.02E-07 4.31E-08 2.48E-08 1.64E-08 E
1.77E-05 3.OOE-06 1.27E-06 6.83E-07 4.41E-07 1.66E-07 4.60E-08 2.01E-08 1.15E-08 7.57E-09 ESE 9.70E-06 1.77E-06 7.58E-07 4.02E-07 2.57E-07 9.59E-08 2.33E-08 8.80E-09 5.OOE-09 3.25E-09 SE 1.03E-05 1.91 E-06 8.31E-07 4.46E-07 2.85E-07 1.07E-07 2.34E-08 7.46E-09 4.23E-09 2.73E-09 SSE 7.77E-06 1.40E-06 5.92E-07 3.18E-07 2.06E-07 8.21E-08 1.89E-08 5.86E-09 3.32E-09 2.15E-09 S
6.24E-06 1.23E-06 5.70E-07 3.14E-07 2.07E-07 8.83E-08 2.13E-08 6.33E-09 3.59E-09 2.31E-09 SSW 5.98E-06 1.12E-06 4.90E-07 2.64E-07 1.69E-07 6.49E-08 1.49E-08 4.91E-09 2.79E-09 1.80E-09 SW 4.64E-06 8.66E-07 3.91E-07 2.14E-07 1.39E-07 5.65E-08 1.29E-08 3.79E-09 2.15E-09 1.38E-09 WSW 3.44E-06 6.11E-07 2.70E-07 1.51 E-07 9.96E-08 4.33E-08 1.19E-08 3.87E-09 1.77E-09 8.75E-10 W
1.42E-06 2.47E-07 1.01 E-07 5.27E-08 3.32E-08 1.24E-08 2.92E-09 1.02E-09 5.66E-10 3.56E-10 WNW 8.85E-07 1.52E-07 5.79E-08 2.89E-08 1.78E-08 6.12E-09 1.47E-09 6.09E-10 3.38E-10 2.13E-10 NW 1.29E-06 2.24E-07 8.54E-08 4.17E-08 2.56E-08 8.59E-09 2.01E-09 8.29E-10 4.59E-10 2.89E-10 NNW 2.55E-06 4.48E-07 1.80E-07 9.13E-08 5.55E-08 1.79E-08 3.93E-09 1.62E-09 9.01E-10 5.68E-10 3-22
TABLE 3-7 2009 SSES Annual Relative Concentrations - D/Q (m2 )
Miles Direction 0-1 1-2 2-3 3-4 4-5 5-10 10-20 20-30 30-40 40-50 From N
2.74E-08 4.03E-09 1.65E-09 7.84E-10 4.63E-10 1.47E-10 3.51E-11 1.29E-11 6.90E-12 4.33E-12 NNE 4.20E-08 6.50E-09 2.82E-09 1.34E-09 7.90E-10 2.46E-10 5.74E-11 2.11E-11 1.13E-11 7.08E-12 NE 4.95E-08 7.46E-09 3.19E-09 1.54E-09 9.16E-10 2.95E-10 7.23E-11 2.66E-11 1.42E-11 8.93E-12 ENE 6.65E-08 1.03E-08 4.60E-09 2.25E-09 1.33E-09 4.20E-10 9.58E-11 3.36E-11 1.79E-11 1.13E-11 E
3.29E-08 4.80E-09 1.96E-09 9.34E-10 5.57E-10 1.84E-10 4.65E-11 1.71E-11 9.15E-12 5.75E-12 ESE 2.24E-08 3.39E-09 1.44E-09 6.97E-10 4.17E-10 1.38E-10 3.14E-11 1.01 E-11 5.41 E-12 3.40E-12 SE 2.91E-08 4.42E-09 1.93E-09 9.53E-10 5.72E-10 1.93E-10 4.02E-11 1.10E-11 5.88E-12 3.69E-12 SSE 2.54E-08 3.79E-09 1.61 E-09 7.97E-10 4.86E-10 1.74E-10 3.81E-11 1.01 E-11 5.41E-12 3.40E-12 S
2.69E-08 4.32E-09 2.03E-09 1.04E-09 6.50E-10 2.51E-10 5.87E-11 1.51 E-11 8.04E-12 5.05E-12 SSW 3.13E-08 4.78E-09 2.15E-09 1.09E-09 6.57E-10 2.29E-10 5.09E-11 1.45E-11 7.76E-12 4.87E-12 SW 3.89E-08 6.17E-09 2.90E-09 1.50E-09 9.28E-10 3.49E-10 7.88E-11 2.01E-11 1.07E-11 6.73E-12 WSW 3.60E-08 5.55E-09 2.59E-09 1.39E-09 8.82E-10 3.64E-10 1.02E-10 2.96E-11 1.30E-11 6.35E-12 W
1.49E-08 2.24E-09 9.68E-10 4.83E-10 2.95E-10 1.05E-10 2.57E-1 1 8.06E-12 4.30E-12 2.70E-12 WNW 7.98E-09 1.15E-09 4.64E-10 2.22E-10 1.32E-10 4.27E-11 1.05E-11 3.88E-12 2.07E-12 1.30E-12 NW 1.19E-08 1.74E-09 6.98E-10 3.25E-10 1.92E-10 6.1OE-11 1.46E-11 5.38E-12 2.87E-12 1.81E-12 NNW 2.31E-08 3.43E-09 1.45E-09 7.OOE-10 4.10E-10 1.25E-10 2.81E-11 1.04E-11 5.53E-12 3.47E-12 3-23
TABLE 3-8 2009 ATMOSPHERIC DISPERSION ESTIMATES FOR RETDAS INPUT AT SELECTED LOCATIONS X/Q DEC+
AFFECTED (1)
(2)
(3)
(4)
SECTOR LOCATION MILES X/Q X/Q DEC DEP DEPOSITION 10/SSW Maximum (X/Q) Site 0.39 Boundary 1.29E-05 1.29E-05 1.20E-05 6.38E-08 9/S Closest (X/Q) Site Boundary 0.38 6.66E-06 6.65E-06 6.20E-06 4.41 E-08 12/WSW Maximum (X/Q) Residence 1.3 9.55E-06 9.47E-06 8.16E-06 1.32E-08 3/NE Maximum (D/Q) Residence 0.9 2.15E-06 2.15E-06 1.89E-06 1.45E-08 12/WSW Maximum (D/Q) Garden 1.3 9.55E-06 9.47E-06 8.16E-06 1.32E-08 12 / WSW Maximum (D/Q) Dairy 1.7 6.44E-06 6.37E-06 5.39E-06 8.47E-09 Maximum (D/Q) Meat 1.7 12/WSW Producer 6.44E-06 6.37E-06 5.39E-06 8.47E-09 3/NE Riverlands / EIC 0.7 3.11E-06 3.1OE-06 2.78E-06 2.21E-08 12 / WSW Tower's Club 0.5 4.09E-05 4.08E-05 3.74E-05 6.63E-08 NEAREST RESIDENCE WITHIN A 5-MILE RADIUS BY SECTOR SECTOR AFFECTED X/Q DEC NUMBER SECTOR NAME MILES X/Q X/Q DEC
+DEP DEPOSITION 1
N H. Burd 1.3 1.78E-06 1.77E-06 1.53E-06 5.49E-09 2
NNE E. Ashbridge III 1
2.39E-06 2.38E-06 2.08E-06 9.56E-09 3
NE W. Tuggle 0.9 2.15E-06 2.15E-06 1.89E-06 1.45E-08 4
ENE D. Barberi 2.1 4.33E-07 4.31 E-07 3.56E-07 3.36E-09 5
E L.Kozlowski/W. Witts 1.4 3.24E-07 3.23E-07 2.76E-07 2.52E-09 6
ESE R. Panetta 0.5 9.67E-07 9.66E-07 8.84E-07 7.96E-09 7
SE J. Futoma 0.5 1.41 E-06 1.40E-06 1.29E-06 1.19E-08 8
SSE J. Naunczek 0.6 2.11E-06 2.11E-06 1.91 E-06 1.68E-08 9
S S. Slusser 1
1.55E-06 1.54E-06 1.35E-06 8.17E-09 10 SSW S. Molnar 0.9 3.82E-06 3.80E-06 3.35E-06 1.55E-08 11 SW F. Michael 1.5 3.43E-06 3.40E-06 2.90E-06 7.47E-09 12 WSW F. Michael 1.3 9.55E-06 9.47E-06 8.16E-06 1.32E-08 13 W
F. Hummel 1.2 5.01 E-06 4.97E-06 4.31 E-06 7.1OE-09 14 WNW R. Orlando 0.8 5.29E-06 5.26E-06 4.68E-06 9.98E-09 15 NW B. Kramer 0.7 7.54E-06 7.50E-06 6.75E-06 1.81 E-08 16 NNW G. John 0.6 6.48E-06 6.45E-06 5.84E-06 1.85E-08 NEAREST GARDEN WITHIN A 5-MILE RADIUS BY SECTOR SECTOR AFFECTED NAME MILES X/Q X/Q DEC X/Q DEC DEPOSITION NUMBER SECTOR
+DEP 1
N J. Wojcik 3.2 4.70E-07 4.63E-07 3.68E-07 1.24E-09 2
NNE R. Chapin 2.3 6.89E-07 6.82E-07 5.61 E-07 2.44E-09 3
NE F. Kremski 2.6 4.52E-07 4.48E-07 3.64E-07 2.69E-09 4
ENE G. Dennis 2.4 3.55E-07 3.52E-07 2.88E-07 2.76E-09 5
E W. Daily 1.8 2.16E-07 2.15E-07 1.80E-07 1.66E-09 6
ESE B. Smith 3.1 4.71 E-08 4.67E-08 3.71 E-08 2.89E-10 7
SE T. Scholl 0.6 1.07E-06 1.06E-06 9.62E-07 8.64E-09 8
SSE H. Roinick 2.9 1.68E-07 1.67E-07 1.33E-07 1.05E-09 9
S T. Stemrich 2.7 2.99E-07 2.97E-07 2.40E-07 1.39E-09 10 SSW S. Bodnar 1.2 2.51 E-06 2.50E-06 2.16E-06 9.50E-09 11 SW D. Bankes 1.9 2.37E-06 2.35E-06 1.96E-06 5.04E-09 12 WSW F. Michael 1.3 9.55E-06 9.47E-06 8.16E-06 1.32E-08 13 W
F. Hummel 1.2 5.01 E-06 4.97E-06 4.31 E-06 7.1OE-09 14 WNW P. Moskaluk 1.3 2.58E-06 2.56E-06 2.21 E-06 4.34E-09 15 NW R. Reider 4.5 3.82E-07 3.71 E-07 2.85E-07 5.72E-10 16 NNW P. Culver 4
3.32E-07 3.25E-07 2.52E-07 6.12E-10 3-24
TABLE 3-8 (continued)
NEAREST ANIMAL RAISED FOR MEAT CONSUMPTION WITHIN A 5-MILE RADIUS BY SECTOR SECTOR AFFECTED NAME MILES X/Q X/
/
DEPOSITION NUMBER SECTOR DEC+DEP 2
NNE R.Chapin 2.3 6.89E-07 6.82E-07 5.61 E-07 2.44E-09 4
ENE G.Dennis 2.4 3.55E-07 3.52E-07 2.88E-07 2.76E-09 5
E W. Daily 1.8 2.16E-07 2.15E-07 1.80E-07 1.66E-09 6
ESE B. Smith 3.1 4.72E-08 4.68E-08 3.71 E-08 2.89E-10 10 SSW K. & C. Drasher 3.5 4.26E-07 4.20E-07 3.30E-07 1.34E-09 12 WSW T. & M Berger 1.7 6.44E-06 6.37E-06 5.39E-06 8.47E-09 ALL DAIRY LOCATIONS SECTOR AFFECTED NAME MILES X/Q X/Q DEC X/O DEPOSITION NUMBER SECTOR DEC+DEP 5
E W.Bloss 4.5 4.42E-08 4.37E-08 3.32E-08 2.94E-10 6
ESE F.Rinehimer 4.2 2.69E-08 2.66E-08 2.04E-08 1.52E-10 10 SSW K. & C. Drasher 3.5 4.26E-07 4.20E-07 3.30E-07 1.34E-09 10 SSW K.Davis 14.01 3.11E-08 2.92E-08 1.93E-08 6.63E-11 12 WSW T. & M. Berger 1.7 6.37E-06 6.37E-06 5.39E-06 8.47E-09 13 W
J. Dent 5
4.90E-07 4.73E-07 3.60E-07 4.43E-10 1
X/Q RELATIVE CONCENTRATION (SEC/M) 2 X/Q DEC DECAYED AND UNDEPLETED, HALF-LIFE 2.26 DAYS (SEC/M")
3 X/Q DEC+DEP DECAYED AND DEPLETED, HALF-LIFE 8 DAYS (SEC/M-)
4 DEPOSITION RELATIVE DEPOSITION RATE (1/M')
3-25
FIGURE 3-1 2009 ANNUAL WIND ROSE 10M LEVEL - PRIMARY TOWER WIND ROSE (WINDS FROM)
N 0.00% PERCENT CALMS (NOT INCLUDED IN PLOT) 16%
Start Date: 1/1/2009 00:00 End Date: 1213112009 23:00
-Sensors Selected 10 SPD 10 WD
-Legend A WIND SPEED LESS THAN 3.5 MPH WIND SPEED LESS THAN 7.5 MPH o WIND SPEED LESS THAN 12.5MPH WIND SPEED GREATER THAN 12.5 MPH U
This wind rose displays the frequency of hourly average wind direction from a given sector. In 2009, the predominant wind direction occurred 14.3 % of the time from the ENE sector. The average wind speed was 5.0 mph and the average wind speed for the predominant sector (ENE) was 2.7 mph. The sector with the highest average wind speed was WSW (9.1 mph).
3-26
FIGURE 3-2 2009 ANNUAL WIND ROSE 60M LEVEL - PRIMARY TOWER WIND ROSE (WINDS FROM)
N 0.02% PERCENT CALMS (NOT INCLUDED IN PLOT)
Start Date: 1/11/2009 00:00 End Date: 12/31/2009 23:00
-Sensors Selected 60 SPD 60 WD
-Legend A WIND SPEED LESS THAN 3.5 MPH WIND SPEED LESS THAN 7.5 MPH to WIND SPEED LESS THAN 12.5 MPH x WIND SPEED GREATER THAN 12.5 MPH This wind rose displays the frequency of hourly average wind direction from a given sector. In 2009, the predominant wind direction occurred 18.2 % of the time from the NNE sector. The average wind speed was 7.8 mph and the average wind speed for the predominant sector (NNE) was 6.7 mph. The sector with the highest average wind speed was WSW (13.0 mph.).
3-27
FIGURE 3-3 PASQUIL STABILITY CLASS PREVALENCES DATA Period: 2009 Joint Frequency Distributions at 10 Meters Wind Speed and Direction IOM vs. Delta Temperature 60-IOM (Based on 8,589 Valid Hours)
F 10.4%
G A
B 6.5 24 22%
.4.8%
E 27.3%
D 46.9%/o 3-28
SECTION 4 DOSE MEASUREMENTS AND ASSESSMENTS 4-1
Radiological Impact on Man Sampling and analysis of airborne and waterborne effluents were performed in accordance with the frequencies, types of analysis, and Lower Limit of Detection (LLD) outlined in the PPL Susquehanna, LLC Technical Requirements Manual.
Radioactive material was detected in some of the airborne and waterborne effluent samples analyzed. Dose calculations using measured effluent activity levels, meteorological data from the current reporting period and average river flow dilution factors resulted in estimated doses to individuals at levels below 10 CFR 20 and 10 CFR 50, Appendix I limits. Direct radiation resulting from plant operation (reported in the 2009 Annual Radiological Environmental Operating Report) contributed a maximum of 6.80E-1 mrem (measured at TLD Location 9S2 and based on an occupancy time by a member of the public of 20 hours2.314815e-4 days <br />0.00556 hours <br />3.306878e-5 weeks <br />7.61e-6 months <br /> per quarter) at the Protected Area Boundary south of the plant. The maximum organ (including thyroid)/total body dose from all airborne effluent is 3.46E-1 mrem (CHILD, LUNG Table 4-4). The maximum organ/total body dose from all liquid effluent is 2.55E-3 mrem (TEEN, GI-LLI Table 4-2). Conservatively adding the maximum organ (including thyroid)/total body dose from liquid and gaseous effluent and the maximum total body dose determined from direct radiation bounds the dose that any member of the public receives from station operations. The result (1.03 mrem) is 4.12% of the 40CFR190 limit of 25 mrem to total body/organ (except thyroid) and 1.37% of the 40CFR1 90 limit of 75 mrem to the thyroid.
Doses to a maximally exposed member of the public from waterborne effluents are calculated for fish ingestion and shoreline exposure at the plant outfall, and drinking water ingestion at Danville, PA. Site specific parameters used in the calculations for the Danville receiver, specific for actual average blowdown and river level for the entire year are shown in Table 4-1.
TABLE 4-1 SITE-SPECIFIC PARAMETERS USED FOR RETDAS CALCULATIONS (DANVILLE RECEIVER)
FOR 2009 PARAMETER ENTIRE YEAR Cooling Tower Blowdown (CFS) 20.1 Average Net River Level (ft.)
6.6 Dilution Factor at Danville(1) 378.8 Transit time to Danville (hr.)(1) 26.2
(')From ODCM-QA-005, Att. E 4-2
Summaries of maximum individual doses resulting from airborne and waterborne radioactive effluent releases from each unit are given in Table 4-2. Meteorological data from Section 3 were used to calculate the dose from airborne effluents.
The Radioactive Effluent Release Report includes an assessment of the radiation dose from radioactive effluents to members of the public within the site boundary.
Within the Site Boundary there are several areas frequented by members of the public. There are no significant exposure pathways from waterborne effluents in these areas. Doses from airborne effluent are calculated for members of the public for the following locations: Riverlands Energy Information Center, the Towers Club, and residence with the maximum X/Q value; the garden, dairy and meat producing farm with the maximum D/Q value; and the site boundary with the maximum X/Q value. Summaries of the calculated maximum doses within the site boundary and selected locations beyond the site boundary resulting from airborne effluents are presented in Table 4-4. The above referenced locations are shown on Figure 4-1.
In the area comprising the Riverlands recreation area, which surrounds the Energy Information Center, three pathways of radiation exposure can be identified: plume, ground, and inhalation. There are no significant exposure pathways from waterborne effluents in this area. There are approximately 100,000 visitors to the Riverlands/Energy Information Center complex each year. For dose calculations, it is assumed the visitor stays in the area for one hour. The calculated dose rate and collective dose for visitors to the Riverlands/Energy Information Center during 2009 are shown on Table 4-3.
Use of the RETDAS code yields calculated doses for the Riverlands area for the report period. These doses assume an occupancy factor of 100% for a member of the public during 2009. These calculated dose values are shown on Table 4-4.
4-3
TABLE 4-2
SUMMARY
OF MAXIMUM INDIVIDUAL DOSES TO MEMBERS OF THE PUBLIC DATA PERIOD: 1/1/09 TO 12131109 E STIMEATD MIAXIMIUM LIMIT AGE APPLICABLE.
DOSE PERCENT (MREMI/
UNT EFFLUENT' GROUP
- ORGAN, (MIREMI/MRAD)
LOCAKTION OF LIMIT MRAD)( 2 )
DIST AFFECTED (MILES)
SECTOR 1
Liquid(l" Teen Total Body 8.50E-04 (3) 0.03 3
1 Liquid(l" Teen GI-LLI 1.28E-03 (3) 0.01 10 I
Noble Gas N/A Air Dose 0.OOE+00 0.5 WSW 0
10 (Gamma-MRAD)
I Noble Gas N/A Air Dose 0.OOE+00 0.5 WSW 0
20 (Beta-MRAD)
I Airborne Child Liver 1.48E-01 0.5 WSW 1.00 15
Liquid"'l Teen GI-LLI 1.28E-03 (3) 0.01 10 2
Noble Gas N/A Air Dose 0.OOE+00 0.5 WSW 0
10 (Gamma-MRAD) 2 Noble Gas N/A Air Dose 0.OOE+00 0.5 WSW 0
20 (Beta-MRAD) 2 Airborne Child Lung 1.98E-01 0.5 WSW 1.32 15
(')Estimated dose is based on a site total activity release equally divided between Unit 1 and Unit 2.
(2)10 CFR 50, Appendix I limits are in terms of mrad or mrem/reactor-year for airborne and waterborne effluent from each unit.
(3)Doses from liquid effluent are estimated from fish ingestion and shoreline exposure at the site outfall and from the drinking water pathway at Danville, PA.
4-4
TABLE 4-3 CALCULATED COLLECTIVE DOSES TO MEMBERS OF THE PUBLIC WITHIN THE RIVERLANDS/ENERGY INFORMATION CENTER COMPLEX DATA PERIOD: 1/11/09 TO 12/31/09 COLLECTIVE APPLICABLE DOSE RATE"'
DOSE (2)
,EFFLUENT AGE GROUP, ORAN (MREM/HR),
(PERSON-REM)
Noble Gas N/A Total Body 0
0 Noble Gas N/A Skin 0
0 Iodine, Tritium and Child Liver 3.24E-06 3.24E-04 Particulates I
II (1)Estimated dose and dose rate is based on annual site total activity release.
(2)Collective dose is based on 100,000 person-hours.
4-5
TABLE 4-4
SUMMARY
OF MAXIMUM INDIVIDUAL DOSES FROM AIRBORNE EFFLUENT MAXIMUM MAXIMUM MAXIMUM TOTAL BODY ORGAN THYROID DOSE DOSE DOSE LOCATION PATHWAY (MREM)
(MREM)
(MREM)
- 1.
Maximum site boundary X/Q Total (All) 1.14E-61 (CHILD) 1.14E-01 (CHILD, GI-LLI) 1.13E-01 (CHILD)
- 2.
Maximum X/Q Residence +
Maximum D/Q Garden Total (All) 8.02E-02 (CHILD) 8.05E-02 (CHILD, LUNG) 8.01 E-02 (CHILD)
- 3.
Maximum D/Q Dairy +
Maximum D/Q Meat Total (All) 5.41 E-02 (CHILD) 5.42E-02 (CHILD, LUNG) 5.40E-02 (CHILD)
- 4.
Tower's Club Total (All) 3.45E-01 (CHILD) 3.46E-01 (CHILD, LUNG) 3.44E-01 (CHILD)
- 5.
Riverland/EIC 5._______________Total (All) 2.82E-02 (CHILD) 2.84E-02 (CHILD, GI-LLI) 2.81 E-02 (CHILD)
Note: The doses shown above are based on 100% occupancy at the indicated locations. They are based on a composite of all pathways resulting in a total dose to the maximally exposed individual due to airborne effluents from both Unit-1 and Unit-2 operations.
4-6
FIGURE 4-1 AIRBORNE-DOSE CALCULATION LOCATIONS 16-NNW 1
12-Indicates airborne-dose calculation location per Table 4-4 4-7
SECTION 5 CHANGES TO THE OFFSITE DOSE CALCULATION MANUAL (ODCM),
TECHNICAL REQUIREMENTS MANUAL (TRM)
AND THE SOLID RADIOACTIVE WASTE PROCESS CONTROL PROGRAM 5-1
CHANGES TO THE OFFSITE DOSE CALCULATION MANUAL The PPL Susquehanna, LLC ODCM consists of nine (9) individual procedures.
ODCM-QA-008, Radiological Environmental Monitoring Program, was revised on April 9, 2009. The revision: 1) Updated Attachments D and G to add four new groundwater monitoring well sample locations and two new surface water sample locations; 2)
Updated position titles.
5-2
CHANGES TO THE TECHNICAL REQUIREMENTS MANUAL Section 3.11 and 3.6.1 of the Unit-1 and Unit-2 Technical Requirements Manual (TRM) by reference are part of the ODCM. The following limits and requirements are contained in Section 3.11: liquid and gaseous effluent dose limits, liquid and gaseous effluent treatment system operability criteria (based on effluent dose), liquid and gaseous effluent radiation monitor operability criteria and the conduct of the Radiological Environmental Monitoring Program. Section 3.6.1 contains requirements for venting or purging of primary containment.
Section 3.11.2.6 of the Unit-1 and Unit-2 TRM was revised on September 8, 2009. The revision clarified the Completion Time requirements for TRO 3.11.2.6. Conditions H and J.
5-3
PROCESS CONTROL PROGRAM CHANGES The following changes were made to the Process Control Program and implementing procedures during 2009. None of the changes reduce the overall conformance of the solidified waste product to existing criteria for solid wastes. All changes were reviewed and approved by PORC (as necessary) as documented on the attached summary of procedure changes. The following procedures were changed:
- 1.
NDAP-QA-0646, Solid Radioactive Waste Process Control Program
- 2.
WM-RP-1 07, Transfer and Dewater A (B) RWCU Phase Separator
- 3.
WM-RP-1 09, Transfer of Waste Sludge Phase Separator
- 4.
WM-RP-1 10, Transfer and Dewatering of Waste Mix Tanks
- 5.
WM-RP-1 13, Transfer and Dewatering of Waste Mix Tanks
- 6.
WM-RP-106, Transfer and Dewatering Bead Resin
- 7.
CH-RC-075, Sample Preparation and Analysis of Dewatered Radwaste
- 8.
CH-RC-076, Gamma Spectral Analysis
- 9.
WM-PS-150, 10CFR61 Non-Process Waste Stream Sampling
- 10.
WM-RP-009, Combustible Gas Check and Closure of Processing Liners and High Integrity Containers
- 11.
WM-RP-01 0, Liner Decanting
- 12.
WM-RP-104, Gross Dewatering
- 13.
WM-RP-1 12, Dewatering Waste to Disposal -Criteria
- 14.
WM-RP-012, Handling and Use of Steel Liners and High Integrity Containers
- 15.
WM-PS-1 00, Shipment of Radioactive Waste
- 16.
WM-PS-1 10, General Shipment of Radioactive Material 5-4
NDAP-QA-0646 continues to fully implement the requirements and intent of the following:
- 1.
Sections 11.4 and 13.5 of the FSAR
- 2.
Section 3.7.4 of the Technical Requirements Manual
- 3.
10 CFR 20, 10 CFR 61, 10 CFR 71,49 CFR 100-177, and 40 CFR 261 Compliance with all applicable regulatory requirements listed above continues to be met as the result of these changes to the program. These changes to the Process Control Program will not reduce the overall conformance of the solidified waste product to existing criteria for solid wastes.
5-5
PROCEDURE REVISION
SUMMARY
NDAP-QA-0646 The following changes will not reduce the overall conformance of the solidified waste product to existing criteria for solid wastes.
- 1.
Updated references to New Vendor Topical Reports.
- 2.
Clarified Quality Control responsibilities.
- 3.
Updated Waste Types section.
- 4.
Deleted various requirements related to Barnwell Waste Management Facility which no longer takes PPL Radwaste.
- 5.
Minor administrative changes.
- 6.
Updated Shipping of Radioactive Waste section (6.13).
- 7.
Added use of Applicability Determination for evaluation of process or operational changes.
- 8.
Removed unnecessary Foreman Effluents signoffs from Form NDAP-QA-0646-1 and NDAP-QA-0646-2.
- 9.
Updated Attachments C and D.
PROCEDURE REVISION
SUMMARY
WM-RP-107
- 1.
Procedure revision to incorporate the new processing area modification system:
Self Engaging Dewatering System (SEDS).
PROCEDURE REVISION
SUMMARY
WM-RP-109
- 1.
Procedure revision to incorporate the new processing area modification system:
Self Engaging Dewatering System (SEDS).
PROCEDURE REVISION
SUMMARY
WM-RP-110
- 1.
Interim change to support the installation of EC/TEC 1135363, Temporary Processing of Waste Mix Tanks.
5-6
PROCEDURE REVISION
SUMMARY
WM-RP-113
- 1.
This is a newly issued procedure number which replaces the old WM-RP-1 10.
WM-RP-1 10 has been revised to reflect interim changes until the radwaste modification is complete.
PROCEDURE REVISION
SUMMARY
WM-RP-106
- 1.
Revised procedure to support processing area modifications.
PROCEDURE REVISION
SUMMARY
- 1.
Incorporate PCAFs 2003-1628 and 2004-3209.
- 2.
Revise Step 7.2 to correspond with changes made to solid Radwaste processing via EC No. 1088096 (Radwaste Processing Changes).
- 3.
Add reference to AR No. 1144103 to support Item 2 above.
- 4.
Update position title of "Chemistry Supervisor" to "Manager - Plant Chemistry/Environmental".
- 5.
Add "ADHERENCE LEVEL: REFERENCE USE" to procedure cover sheet.
PROCEDURE REVISION
SUMMARY
- 1.
Revise Step 7.4.2.e (7) to add guidance to notify Chemistry Supervision if unable to identify/select an unidentified isotope after reviewing a spectral energy listing.
PROCEDURE REVISION
SUMMARY
WM-PS-150
- 1.
Clarified DAW sampling steps.
- 2.
Updated the procedure adherence level.
- 3.
Changed references to Effluents Management Health Physicist to Health Physicist - Radwaste to reflect current staffing.
- 4.
Updated types of filters used.
5-7
PROCEDURE REVISION
SUMMARY
WM-RP-009
- 1.
Procedure revised due to Processing Area Modification.
- 2.
Incorporate PCAFs 2005-1184 and 2005-1407.
PROCEDURE REVISION
SUMMARY
WM-RP-010
- 1.
Revised procedure to support processing area modifications.
- 2.
Incorporate PCAF 2004-1715 PROCEDURE REVISION
SUMMARY
WM-RP-104
- 1.
Revised procedure due to processing area modifications.
PROCEDURE REVISION
SUMMARY
WM-RP-112
- 1.
New procedure written to address changes in methodology for dewatering waste to disposal criteria. This procedure replaces WM-RP-1 11.
PROCEDURE REVISION
SUMMARY
WM-RP-012
- 1.
Complete rewrite for new container types used for radwaste processing.
- 2.
Incorporate PCAF 2008-1197, as appropriate for new containers.
- 3.
Minor editorial changes.
PROCEDURE REVISION
SUMMARY
WM-PS-100
- 1.
Added vendor computer program error tracking mechanism.
- 2.
Updated Form WM-PS-100-1 due to processing area modification.
- 3.
Removed steps and forms related to the Barnwell Waste Management Facility due to PPL inaccessibility to the disposal site.
5-8
PROCEDURE REVISION
SUMMARY
WM-PS-110
- 1.
Minor administrative enhancements.
- 2.
Incorporated PCAF 2006-1314.
- 3.
Changed the US Government agency that we monitor for security threats to the US Department of Homeland Security.
- 4.
Added requirement to notify the Shift Manager and write an AR if a shipment is determined to be lost or missing.
5-9
SECTION 6 MISCELLANEOUS TECHNICAL REQUIREMENTS MANUAL (TRM),
FSAR, 40CFR190 AND NEI GROUNDWATER PROTECTION INITIATIVE REPORTING 6-1
- 1. TRM Action 3.11.1.4.F.2 requires the reporting of Liquid Radwaste Effluent Monitoring Instrumentation inoperability not corrected in a timely manner.
None to report for 2009.
- 2. TRM Action 3.11.1.5.C.1 requires the reporting of Radioactive Liquid Process Effluent Monitoring Instrumentation inoperability not corrected in a timely manner.
None to report for 2009.
- 3. TRM Action 3.11.2.6.K requires an explanation for Radioactive Gaseous Effluent Monitoring Instrumentation required actions and completion times not met.
None to report for 2009.
- 4. TRM Action 3.11.4.1.F.2 requires reporting the cause of the unavailability of milk or fresh leafy vegetable samples and identify the new locations for obtaining replacements.
None to report for 2009
- 5. TRM Action 3.11.4.2.A requires reporting when land use census identifies a new location which yields a calculated dose or dose commitment greater than the values currently being calculated in Requirement 3.11.2.3 (Gaseous Effluent Dose due to Iodine, Tritium, and Radionuclides in Particulate Form).
None to report for 2009.
- 6. TRM Action 3.11.4.2.B requires reporting when land use census identifies locations that yield a calculated dose or dose commitment (via the same exposure pathway) 20 percent greater than at a location from which samples are currently being obtained in accordance with Requirement 3.11.4.1 (Radiological Environmental Monitoring Program).
None to report for 2009.
- 7. The limits outlined in 40CFR1 90.10 (Environmental Standards for the Uranium Fuel Cycle-Standards for Normal Operations) were not exceeded by station operations during 2009. Refer to Section 2 and Page 4-2 for specific values.
6-2
- 8. FSAR Section 11.6.11 requires the reporting of airborne radioactivity detected in the Low Level Radwaste Holding Facility.
No airborne radioactivity detected above analysis MDC's in air samples from the Low Level Radwaste Holding Facility during 2009.
- 9. The PPL Susquehanna station has implemented an Action Plan in response to the NEI Initiative on Groundwater Protection. Part of the Action Plan includes the assessment of the current groundwater monitoring program.
Groundwater is sampled and analyzed quarterly as part of the Radiological Environmental Monitoring Program (REMP). REMP groundwater sampling locations are defined in ODCM-QA-008 Attachment G. In August 2006, additional groundwater sampling was initiated at locations which are not listed in the ODCM. The additional locations are three manholes which collect water from a perimeter drain system. The perimeter drain system consists of perforated piping installed just above the footing along the exterior base of the vertical walls of the reactor, turbine and radwaste buildings. Outlined in Table 6-1 are the tritium analysis results from sampling of the perimeter drain system. No gamma emitting radionuclides were identified above analysis MDC's for the perimeter drain samples in 2009. The tritium results reported in Table 6-1 did not exceed any Reporting Level thresholds in the PPL Susquehanna Technical Requirements Manual or any reporting criteria established in response to the NEI Groundwater Protection Initiative. Figure 6-1 is a trend graph of airborne and waterborne effluent tritium releases from the PPL Susquehanna Station starting in 1982.
6-3
TABLE 6-1 NEI Ground Water Protection Initiative Reporting Perimeter Drain Samplinq Results:
2009 Manhole FD-1 Manhole FD-2 Manhole FD-3 (16S3-NW corner (9S3 - I/S RCA @ U2 (7S9 - E of U2 CST) of RW Bldg.)
HP Cont. Pt. Closet)
Date Tritium (pCi/liter)
Tritium (pCi/liter)
Tritium (pCi/liter) 18/2009 430 288 207 11/2009 335 243 295 8/10/2009 241 136 214 11/9/2009 565 432 262 6-4
Figure 6-1 SSES Tritium Effluent Releases (Airborne, Waterborne & Total Curies Released)
- o 250..
200 50 Nq N0 b N,
,,N, q,q,q,
q f
Year Airborne H-3 u-Waterborne H-3
-Total Curies 6-5
SECTION 7 CORRECTIONS TO PREVIOUS RADIOACTIVE EFFLUENT RELEASE REPORTS 7-1
CORRECTIONS TO PREVIOUS RADIOACTIVE EFFLUENT RELEASE REPORTS No corrections to previous Radioactive Effluent Release Reports are submitted for this report period.
7-2
SECTION 8 EFFLUENT FROM SYSTEMS CLASSIFIED AS INSIGNIFICANT EFFL UENT PA TH WA YS 8-1
EFFLUENT FROM SYSTEMS CLASSIFIED AS INSIGNIFICANT EFFLUENT PATHWAYS Insignificant Effluent Pathways are: 1) evaporation from the Unit 1 and Unit 2 Condensate Storage Tanks (CST's); 2) evaporation from the common Refueling Water Storage Tank (RWST); 3) gaseous effluent from the Hydrogen Seal Oil, Main Turbine and RFPT lubrication oil mist eliminators which vent to the turbine building roofs.
These pathways are not continuously monitored. The CSTs and RWST are sampled monthly to determine the concentration of radionuclides present in these tanks. Tritium analysis on these samples is performed quarterly. Airborne release to the environment from the tanks is estimated based on conservative estimates of the evaporation rates from each of the tanks using a modified method established within Chapter 7 of EPA AP-42. A conservative carry-over fraction of radionuclides from the water to the evaporated liquid is then assumed. Airborne release to the environment from the demisters conservatively assumes the maximum moisture (condensate) concentration of the lubrication oil as measured via sampling during 2009. The calculation also assumes immediate removal of 100% of the water by the oil mist eliminators as it passes through the turbines.
On April 7, 2009 the auxiliary steam system was identified as contaminated with low levels of tritium (- 2E-5 uCi/cc). Airborne release to the environment from auxiliary steam system operation on April 7, 2009 is estimated based on conservative assumptions of system maximum vent flow rates and maximum identified tritium concentration levels. Offsite dose due to the release of 6.86E-5 Ci tritium from the auxiliary steam system operation on April 7, 2009 is included in the maximum dose to the public from insignificant effluents.
The annual release of tritium, iodines and particulates with half-lives greater than 8 days was calculated based on the conservative assumptions outlined above. The calculated releases are shown in Table 8-1. All nuclides, except for tritium, released from insignificant effluent pathways are negligible compared to the airborne release data shown in Tables 2-1 and 2-2. The maximum dose to the public from a release of 1.05 Ci of tritium is calculated to be 2.89E-3 mrem (child). This is a small fraction of the maximum dose from airborne effluent reported in Section 4.
8-2
TABLE 8-1 ANNUAL RELEASE FROM SYSTEMS CLASSIFIED AS INSIGNIFICANT EFFLUENT PATHWAYS U1-CST and U2-CST and Main Turbine/RFPT Main Turbine/RFPT Nuclide RWST Lube Oil Systems Lube Oil Systems Aux. Steam System Total (Ci)
(Ci)
(Ci)
(Ci)
(Ci)
H-3 4.1OE-02 5.83E-01 4.28E-01 6.86E-05 1.05E+00 Mn-54 1.67E-08 1.91E-09 7.18E-08 9.04E-08 Co-60 3.57E-08 8.32E-09 1.44E-07 1.88E-07 Fe-59 9.71E-l0 O.OOE+00 3.99E-09 4.96E-09 Xe-135 O.OOE+00
- 1. 19E-07 O.OOE+00
- 1. 19E-07 Co-58 1.78E-08 9.24E-10 7.15E-08 9.03E-08 Zn-65 1.04E-09 O.OOE+00 6.30E-09 7.35E-09 Cr-51 7.97E-09 O.OOE+00 3.28E-08 4.08E-08 8-3