Initial Exam 2009-301 Draft Sim/In-Plant JPMs
ML100470435
Person / Time
Site: Catawba  Duke Energy icon.png
Issue date: 02/02/2010
From:
NRC/RGN-II
To:
References
Download: ML100470435 (194)


Text

CANDIDATE EXAMINER JPM09A CATAWBA NUCLEAR STATION INITIAL LICENSE EXAMINATION JOB PERFORMANCE MEASURE JPM09 A Pressurize Cold Leg Accumulator 1A Page 1 of 9 CANDIDATE EXAMINER JPM09 A CATAWBA NUCLEAR STATION INITIAL LICENSE EXAMINATION JOB PERFORMANCE MEASURE JPM09 A Pressurize Cold Leg Accumulator 1A Page 1 of 9

CATAWBA NUCLEAR STATION INITIAL LICENSE EXAMINATION JOB PERFORMANCE MEASURE Pressurize Cold Leg Accumulator 1A Alternate Path:

No Facility JPM #:

CLA-109 KIA Rating(s):

SYS006 A 1.13 (3.5/3.7) Ability to predict and/or monitor changes in parameters (to prevent exceeding design limits associated with operating the ECCS controls including - Accumulator pressure (level, boron concentration).

Task Standard:

Cold Leg Accumulator 1A is pressurized with nitrogen to clear annunciator 1AD-9, E/1.

Preferred Evaluation Simulator:

Preferred Evaluation Perform Simulator X

In-Plant __ _

Perform _~X~

References:

OP/1/A/6200/009 (Cold Leg Accumulator Operation), Enclosure 4.6 rev 073 OP/1/A/6200/010J (annunciator Response for 1AD-9, E/1) rev.

Validation Time: 8 min.

Time Critical: No Simulate __ _

=======================================================================

Candidate:

Time Start:

NAME Time Finish:

Performance Rating: SAT UNSAT Performance Time Examiner:

/

NAME SIGNATURE DATE

=======================================================================

COMMENTS JPM09A Page 2 of 9 CATAWBA NUCLEAR STATION INITIAL LICENSE EXAMINATION JOB PERFORMANCE MEASURE Pressurize Cold Leg Accumulator 1A Alternate Path:

No Facility JPM #:

CLA-109 KIA Rating(s):

SYS006 A 1.13 (3.5/3.7) Ability to predict and/or monitor changes in parameters (to prevent exceeding design limits associated with operating the ECCS controls including - Accumulator pressure (level, boron concentration).

Task Standard:

Cold Leg Accumulator 1A is pressurized with nitrogen to clear annunciator 1AD-9, E/1.

Preferred Evaluation Simulator:

Preferred Evaluation Perform Simulator X

In-Plant __ _

Perform _...!..X~

References:

OP/1/A/6200/009 (Cold Leg Accumulator Operation), Enclosure 4.6 rev 073 OP/1/A/6200/010J (annunciator Response for 1AD-9, E/1) rev xxx Validation Time: 8 min.

Time Critical: No Simulate __ _

=======================================================================

Candidate:

Time Start:

NAME Time Finish:

Performance Rating:

SAT UNSAT Performance Time Examiner:

/

NAME SIGNATURE DATE

=======================================================================

COMMENTS JPM09 A Page 2 of 9

SIMULATOR SETUP SHEET

1. Reset to any 100% power IC set.
2. Reduce pressure in 1A CLA to approximately 600 psig
3. Ensure CLA 1A pressure is below 1AD-9, E/1 setpoint and that the annunciator is lit.
4. Freeze simulator and write to a snap.

IC SELECTED _____

SIMULATOR OPERATOR INSTRUCTIONS:

None.

Tools/Equipment/Procedures Needed:

1. OP/11A162001009 (Cold Leg Accumulator Operation), Enclosure 4.6 revision 073 JPM09 A Page 3 of 9 SIMULATOR SETUP SHEET
1. Reset to any 100% power IC set.
2. Reduce pressure in 1A CLA to approximately 600 psig
3. Ensure CLA 1A pressure is below 1AD-9, E/1 setpoint and that the annunciator is lit.
4. Freeze simulator and write to a snap.

IC SELECTED _____

SIMULATOR OPERATOR INSTRUCTIONS:

None.

Tools/Equipment/Procedures Needed:

1. OP/11A162001009 (Cold Leg Accumulator Operation), Enclosure 4.6 revision 073 JPM09A Page 3 of 9

READ TO OPERATOR DIRECTION TO TRAINEE:

I will explain the initial conditions, and state the task to be performed. All control room steps shall be performed for this JPM, including any required communications. I will provide initiating cues and reports on other actions when directed by you. Ensure you indicate to me when you understand your assigned task. To indicate that you have completed your assigned task return the handout sheet I provided you.

INITIAL CONDITIONS:

Reactor power level is at 100%. Cold Leg Accumulator 1A nitrogen overpressure has decreased and annunciator 1AD-9, E/1 ACCUM TANK A HIILO PRESS is lit.

INITIATING CUES:

Restore CLA 1A pressure to clear annunciator 1AD-9, E/1. The initial conditions for OP/1/A/6200/09, Encl. 4.6 (Increasing Accumulator Pressure) have been satisfied.

JPM09 A Page 4 of 9 READ TO OPERATOR DIRECTION TO TRAINEE:

I will explain the initial conditions, and state the task to be performed. All control room steps shall be performed for this JPM, including any required communications. I will provide initiating cues and reports on other actions when directed by you. Ensure you indicate to me when you understand your assigned task. To indicate that you have completed your assigned task return the handout sheet I provided you.

INITIAL CONDITIONS:

Reactor power level is at 100%. Cold Leg Accumulator 1A nitrogen overpressure has decreased and annunciator 1AD-9, E/1 ACCUM TANK A HIILO PRESS is lit.

INITIATING CUES:

Restore CLA 1A pressure to clear annunciator 1AD-9, E/1. The initial conditions for OP/1/A/6200/09, Encl. 4.6 (Increasing Accumulator Pressure) have been satisfied.

JPM09 A Page 4 of 9

START TIME: __

STEP 2.1:

Open 1NI-47A (C-Leg Accum N2 Sup Cont Isol).

STANDARD:

OPEN pushbutton depressed for 1 NI-47A (Cold Leg Accum N2 Supply Containment Isolation). RED "OPEN" light lit on 1 MC-11.

COMMENTS:

NOTE: If N2 inlet temperature decreases to 65°F, accumulator N2 supply isolation valves will auto close. There is no alarm with this condition.

When N2 inlet temperature increased above 66°F, this condition will auto clear.

CAUTION: Pressurization shall be performed on only one accumulator at a time.

STANDARD: Reads and acknowledges note and caution.

COMMENTS:

STEP 2.2:

Position 1 CB-1 (located behind control panel 1 MC-6, BB-56) to "ON".

STANDARD:

Breaker 1CB-1 placed to the "ON" position. Located inside 1 MC-6 on right side of instrument rack support column.

COMMENTS:

JPM08A CRITICAL STEP SAT UNSAT SAT UNSAT CRITICAL STEP SAT UNSAT Page 5 of 9 START TIME: __

STEP 2.1:

Open 1NI-47A (C-Leg Accum N2 Sup Cont Isol).

STANDARD:

OPEN pushbutton depressed for 1 NI-47A (Cold Leg Accum N2 Supply Containment Isolation). RED "OPEN" light lit on 1 MC-11.

COMMENTS:

NOTE: If N2 inlet temperature decreases to 65°F, accumulator N2 supply isolation valves will auto close. There is no alarm with this condition.

When N2 inlet temperature increased above 66°F, this condition will auto clear.

CAUTION: Pressurization shall be performed on only one accumulator at a time.

STANDARD: Reads and acknowledges note and caution.

COMMENTS:

STEP 2.2:

Position 1CB-1(1ocated behind control paneI1MC-6, BB-56) to "ON".

STANDARD:

Breaker 1CB-1 placed to the "ON" position. Located inside 1 MC-6 on right side of instrument rack support column.

COMMENTS:

JPM08A CRITICAL STEP SAT UNSAT SAT UNSAT CRITICAL STEP SAT UNSAT Page 5 of 9

STEP 2.3:

Open the corresponding valve to increase pressure in the desired accumulator:

1 NI-SO (C-Leg Accum A N2 Supply Isol)

STANDARD:

OPEN pushbutton depressed for 1NI-SO (Cold Leg Accum A N2 Supply Isol). RED "OPEN" light lit on 1 MC-11. Verify that 1A Cold Leg Accumulator pressure is increasing.

(1 NIPS040, 1 NIPSOSO, on 1 MC-11).

COMMENTS STEP 2.4:

If the accumulator N2 supply isolation valve frequently auto closes, ensure the following:

SMXB-FOSE (Safety Injection Accumulator Nitrogen Heater) (AB-S60, HH-S2) is energized.

The thermostat is set at 7soF.

STANDARD: If 1NI-SO cycles closed and reopens, dispatch NLO to check power supply and thermostat setting.

EXAMINER NOTE: If examinee calls to dispatch an operator to check power supply for nitrogen heater and thermostat setting, repeat back only what you are told.

COMMENTS JPM08A CRITICAL STEP SAT UNSAT SAT UNSAT Page 6 of 9 STEP 2.3:

Open the corresponding valve to increase pressure in the desired accumulator:

1 NI-SO (C-Leg Accum A N2 Supply Isol)

STANDARD:

OPEN pushbutton depressed for 1NI-SO (Cold Leg Accum A N2 Supply Isol). RED "OPEN" light lit on 1 MC-11. Verify that 1A Cold Leg Accumulator pressure is increasing.

(1 NIPS040, 1 NIPSOSO, on 1 MC-11).

COMMENTS STEP 2.4:

If the accumulator N2 supply isolation valve frequently auto closes, ensure the following:

SMXB-FOSE (Safety Injection Accumulator Nitrogen Heater) (AB-S60, HH-S2) is energized.

The thermostat is set at 7soF.

STANDARD: If 1 NI-SO cycles closed and reopens, dispatch NLO to check power supply and thermostat setting.

EXAMINER NOTE: If examinee calls to dispatch an operator to check power supply for nitrogen heater and thermostat setting, repeat back only what you are told.

COMMENTS JPM08 A CRITICAL STEP SAT UNSAT SAT UNSAT Page 6 of 9

STEP 2.5:

When the accumulator is at the desired pressure, close the appropriate valve as follows:

Depress the "ClS" pushbutton for the appropriate valve:

1NI-50 (C-leg Accum A N2 Supply Isol)

Verify the appropriate valve is closed:

1 NI-50 (C-leg Accum A N2 Supply Isol)

STANDARD: Determines Cold leg Accumulator 1A N2 overpressure restored within limits by verifying annunciator 1AD-9, E/1 clears. Depress the CLOSE pushbutton for 1 NI-50 (C-leg Accum A N2 Supply Isol).

GREEN "ClSD" light lit on 1 MC-11.

COMMENTS STEP 2.6:

If necessary, repeat Steps 2.3 through 2.5 to increase pressure in additional accumulators.

STANDARD: Determines no other accumulators need pressure increased.

COMMENTS STEP 2.7:

Position 1CB-1 (located behind control panel 1 MC-6, BB-56) to "OFF".

STANDARD: Breaker 1CB-1 placed to "OFF".

COMMENTS JPM08A CRITICAL STEP SAT UNSAT SAT UNSAT SAT

_UNSAT Page 7 of 9 STEP 2.5:

When the accumulator is at the desired pressure, close the appropriate valve as follows:

Depress the "CLS" pushbutton for the appropriate valve:

1 NI-50 (C-Leg Accum A N2 Supply Isol)

Verify the appropriate valve is closed:

1 NI-50 (C-Leg Accum A N2 Supply Isol)

STANDARD: Determines Cold Leg Accumulator 1 A N2 overpressure restored within limits by verifying annunciator 1AD-9, E/1 clears. Depress the CLOSE pushbutton for 1 NI-50 (C-Leg Accum A N2 Supply Isol).

GREEN "CLSD" light lit on 1 MC-11.

COMMENTS STEP 2.6:

If necessary, repeat Steps 2.3 through 2.5 to increase pressure in additional accumulators.

STANDARD: Determines no other accumulators need pressure increased.

COMMENTS STEP 2.7:

Position 1 CB-1 (located behind control panel 1 MC-6, BB-56) to "OFF".

STANDARD: Breaker 1CB-1 placed to "OFF".

COMMENTS JPM08 A CRITICAL STEP SAT UNSAT SAT UNSAT SAT UNSAT Page 7 of 9

STEP 2.8:

Close 1NI-47A (C-Leg Accum N2 Sup Cont Isol).

SAT STANDARD: Depress the CLOSE pushbutton for 1NI-47A (C-Leg Accum N2 Supply Cont Isol). GREEN "CLSD" light lit on 1 MC-11.

UNSAT COMMENTS This JPM is complete.

TIME STOP: __

JPM08A Page 8 of 9 STEP 2.8:

Close 1 NI-47A (C-Leg Accum N2 Sup Cont Isol).

SAT STANDARD: Depress the CLOSE pushbutton for 1 NI-47A (C-Leg Accum N2 Supply Cont Isol). GREEN "CLSD" light lit on 1 MC-11.

UNSAT COMMENTS This JPM is complete.

TIME STOP: __

JPM08 A Page 8 of 9

CANDIDATE CUE SHEET (TO BE RETURNED TO EXAMINER UPON COMPLETION OF TASK)

INITIAL CONDITIONS:

Reactor power level is at 100%. Cold Leg Accumulator 1A nitrogen overpressure has decreased and annunciator 1AD-9, E/1 ACCUM TANK A HI/LO PRESS is lit.

INITIATING CUES:

Restore CLA 1A pressure to clear annunciator 1AD-9, E/1. The initial conditions for OP/1/A16200109, Encl. 4.6 (Increasing Accumulator Pressure) have been satisfied.

CANDIDATE CUE SHEET (TO BE RETURNED TO EXAMINER UPON COMPLETION OF TASK)

INITIAL CONDITIONS:

Reactor power level is at 100%. Cold Leg Accumulator 1A nitrogen overpressure has decreased and annunciator 1AD-9, E/1 ACCUM TANK A HIILO PRESS is lit.

INITIATING CUES:

Restore CLA 1A pressure to clear annunciator 1AD-9, E/1. The initial conditions for OP/1/A/6200109, Ene!. 4.6 (Increasing Accumulator Pressure) have been satisfied.

I I

I

.6 Increasing Accumulator Pressure

1. Initial Conditions 1.1 Review the Limits and Precautions.

OPI1 IA/62001009 Page 1 of2 1.2 Verify the GN System is in operation per OP/OIA/64501008 (Nitrogen System).

1.3 Verify the cold leg accumulators have been filled to the desired levels.

1.4 Obtain key #11 to gain access to the backside of the control boards.

2. Procedure

-- 2.1 Open INI-47A (C-Leg Accum N2 Sup Cont Isol).

-- 2.2 Position 1 CB-l (located behind control pane11MC6, BB-56) to "ON".

NOTE:

IfN2 inlet temperature decreases to 65°F, accumulator N2 supply isolation valves will auto close. There is no alarm associated with this condition. When N2 inlet temperature increased above 66°F, this condition will auto clear.

CAUTION: Pressurization shall be performed on only one accumulator at a time.

2.3 Open the corresponding valve to increase pressure in the desired accumulator:

INI-50 (C-Leg Accum A N2 Supply Iso1)

INI-61 (C-Leg Accum B N2 Supply Iso1)

INI-72 (C-Leg Accum C N2 Supply Iso1)

INI-84 (C-Leg Accum D N2 Supply Iso1) 2.4 IF the accumulator N2 supply isolation valve frequently auto closes, ensure the following:

--. SMXB-F05E (Safety Injection Accumulator Nitrogen Heater) (AB-560, HH-52) is energized.

--. The thermostat is set at 75°F..6 Increasing Accumulator Pressure

1. Initial Conditions 1.1 Review the Limits and Precautions.

OP/l!Al6200/009 Page 1 of2 1.2 Verify the GN System is in operation per OP/OI Al6450/008 (Nitrogen System).

1.3 Verify the cold leg accumulators have been filled to the desired levels.

1.4 Obtain key # 11 to gain access to the backside of the control boards.

2. Procedure

-- 2.1 Open IN1-47A (C-Leg Accum N2 Sup Cont Is01).

-- 2.2 Position lCB-l (located behind control panellMC6, BB-56) to "ON".

NOTE:

1fN2 inlet temperature decreases to 65°F, accumulator N2 supply isolation valves will auto close. There is no alarm associated with this condition. When N2 inlet temperature increased above 66°F, this condition will auto clear.

CAUTION: Pressurization shall be performed on only one accumulator at a time.

2.3 Open the corresponding valve to increase pressure in the desired accumulator:

IN1-50 (C-Leg Accum A N2 Supply 1sol)

IN1-61 (C-Leg Accum B N2 Supply 1sol)

IN1-72 (C-Leg Accum C N2 Supply 1sol)

IN1-84 (C-Leg Accum D N2 Supply 1sol) 2.4 IF the accumulator N2 supply isolation valve frequently auto closes, ensure the following:

--. SMXB-F05E (Safety Injection Accumulator Nitrogen Heater) (AB-560, HH-52) is energized.

--. The thermostat is set at 75°F.

.6 Increasing Accumulator Pressure OP/l!Al6200/009 Page 2 of2 2.S WHEN the accumulator is at the desired pressure, close the appropriate valve as follows:

2.S.1 Depress the "CLS" pushbutton for the appropriate valve:

  • INI-SO (C-Leg Accum A N2 Supply Isol)
  • INI-61 (C-Leg Accum B N2 Supply Isol)
  • INI-72 (C-Leg Accum C N2 Supply Isol)
  • INI-84 (C-Leg Accum D N2 Supply Isol) 2.S.2 Verify the appropriate valve is closed:
  • INI-SO (C-Leg Accum A N2 Supply Isol)
  • INI-61 (C-Leg Accum B N2 Supply Isol)
  • INI-72 (C-Leg Accum C N2 Supply Isol)
  • INI-84 (C-Leg Accum D N2 Supply Isol) 2.6 IF necessary, repeat Steps 2.3 through 2.S to increase pressure in additional accumulators.

--2.7 Position lCB-l (located behind control panellMC6, BB-S6) to "OFF".

--2.8 Close INI-47A (C-Leg Accum N2 Sup Cont Isol).

2.9 Do NOT file this enclosure in the Control Copy folder of this procedure..6 Increasing Accumulator Pressure OP/l!Al6200/009 Page 2 of2 2.S WHEN the accumulator is at the desired pressure, close the appropriate valve as follows:

2.S.1 Depress the "CLS" pushbutton for the appropriate valve:

  • INI-SO (C-Leg Accum A N2 Supply Isol)
  • INI-61 (C-Leg Accum B N2 Supply Isol)
  • INI-72 (C-Leg Accum C N2 Supply Isol)
  • INI-84 (C-Leg Accum D N2 Supply Isol) 2.S.2 Verify the appropriate valve is closed:
  • INI-SO (C-Leg Accum A N2 Supply Isol)
  • INI-61 (C-Leg Accum B N2 Supply Isol)
  • INI-72 (C-Leg Accum C N2 Supply Isol)
  • INI-84 (C-Leg Accum D N2 Supply Isol) 2.6 IF necessary, repeat Steps 2.3 through 2.S to increase pressure in additional accumulators.

--2.7 Position lCB-l (located behind control panellMC6, BB-S6) to "OFF".

--2.8 Close INI-47A (C-Leg Accum N2 Sup Cont Isol).

2.9 Do NOT file this enclosure in the Control Copy folder of this procedure.

CATAWBA NUCLEAR STATION INITIAL LICENSE EXAMINATION JOB PERFORMANCE MEASURE JPM09 B Align the NS System to Cold Leg Recirculation CANDIDATE EXAMINER JPM09 B Page 1 of 11 CATAWBA NUCLEAR STATION INITIAL LICENSE EXAMINATION JOB PERFORMANCE MEASURE JPM09 B Align the NS System to Cold Leg Recirculation CANDIDATE EXAMINER JPM09 B Page 1 of 11

CATAWBA NUCLEAR STATION INITIAL LICENSE EXAMINATION JOB PERFORMANCE MEASURE Align the NS System to Cold Leg Recirculation Alternate Path:

YES Facility JPM #:

NS-102 KIA Rating(s):

SYS026 A4.01 (4.5/4.3) Ability to manually operate and/or monitor in the control room: CCS controls.

Task Standard:

NS Pump 1 B is in operation with suction aligned to the containment sump and RN flow established to the NS heat exchangers.

Preferred Evaluation Simulator:

Preferred Evaluation Perform Simulator X

In-Plant __ _

Perform _-,-X-,---

Simulate __ _

References:

EP/1/N5000/ES-1.3 (Transfer to Cold Leg Recirculation) Enclosure 2 rev 021 Validation Time: 15 min.

Time Critical: No

=======================================================================

Candidate:

Time Start:

NAME Time Finish:

Performance Rating:

SAT UNSAT Performance Time Examiner:

1 NAME SIGNATURE DATE

=======================================================================

COMMENTS JPM09 B Page 2 of 11 CATAWBA NUCLEAR STATION INITIAL LICENSE EXAMINATION JOB PERFORMANCE MEASURE Align the NS System to Cold Leg Recirculation Alternate Path:

YES Facility JPM #:

NS-102 KIA Rating(s):

SYS026 A4.01 (4.5/4.3) Ability to manually operate and/or monitor in the control room: CCS controls.

Task Standard:

NS Pump 1 B is in operation with suction aligned to the containment sump and RN flow established to the NS heat exchangers.

Preferred Evaluation Simulator:

Preferred Evaluation Perform Simulator X

In-Plant __ _

Perform _...!..X"----

Simulate __ _

References:

EP/1/N5000/ES-1.3 (Transfer to Cold Leg Recirculation) Enclosure 2 rev 021 Validation Time: 15 min.

Time Critical: No

=======================================================================

Candidate:

Time Start:

NAME Time Finish:

Performance Rating:

SAT UNSAT Performance Time Examiner:

1 NAME SIGNATURE DATE

=======================================================================

COMMENTS JPM09 B Page 2 of 11

SIMULATOR SETUP SHEET

1. Reset to any power IC snap.
2. Insert MAL-NC013A (Cold Leg Leak) set Severity Value = 27.5.
3. Insert VLV-NS010F (NS20A NS Pmp A Suct From RWST Isol Fail To Position) VALUE = 1
4. Run simulator until "FWST LO-LO Level' alarm is received while performing all required actions of EP/E-O, EP/E-1 and EOP/ES-1.3 up to step 6.
5. Insert MAL-NS001B (CONTAINMENT SPRAY NS PUMP 1A FAILURE), VALUE=AUTO
6. Insert OVR-W042D (ARF-18 CNT AIR RET FAN ON POSITION), VALUE=OFF
7. Insert OVR-W038D (ARF-1A CNT AIR RET FAN ON POSITION), VALUE=OFF
8. Insert OVR-W042C (ARF-1 8 CNT AIR RET FAN OFF POSITION), VALUE=ON
9. Insert OVR-W038C (ARF-1A CNT AIR RET FAN OFF POSITION), VALUE=ON
10. Freeze and write to a snap.

IC SELECTED _____

SIMULATOR OPERATOR INSTRUCTIONS:

Do not place simulator in RUN until the candidate signals that he/she is ready to begin.

Tools/Equipment/Procedures Needed:

1. EP/1/A/SOOO/ES-1.3 (Transfer to Cold Leg Recirculation), Enclosure 2, rev 021 JPM098 Page 3 of 11 SIMULATOR SETUP SHEET
1. Reset to any power IC snap.
2. Insert MAL-NC013A (Cold Leg Leak) set Severity Value = 27.5.
3. Insert VLV-NS010F (NS20A NS Pmp A Suct From RWST Isol Fail To Position) VALUE = 1
4. Run simulator until "FWST LO-LO Level' alarm is received while performing all required actions of EP/E-O, EP/E-1 and EOP/ES-1.3 up to step 6.
5. Insert MAL-NS001B (CONTAINMENT SPRAY NS PUMP 1A FAILURE), VALUE=AUTO
6. Insert OVR-W042D (ARF-1B CNT AIR RET FAN ON POSITION), VALUE=OFF
7. Insert OVR-W038D (ARF-1A CNT AIR RET FAN ON POSITION), VALUE=OFF
8. Insert OVR-W042C (ARF-1B CNT AIR RET FAN OFF POSITION), VALUE=ON
9. Insert OVR-W038C (ARF-1A CNT AIR RET FAN OFF POSITION), VALUE=ON
10. Freeze and write to a snap.

IC SELECTED _____

SIMULATOR OPERATOR INSTRUCTIONS:

Do not place simulator in RUN until the candidate signals that he/she is ready to begin.

Tools/Equipment/Procedures Needed:

1. EP/1/A/5000/ES-1.3 (Transfer to Cold Leg Recirculation), Enclosure 2, rev 021 JPM09 B Page 3 of 11

READ TO OPERATOR DIRECTION TO TRAINEE:

I will explain the initial conditions, and state the task to be performed. All control room steps shall be performed for this JPM, including any required communications. I will provide initiating cues and reports on other actions when directed by you. Ensure you indicate to me when you understand your assigned task. To indicate that you have completed your assigned task return the handout sheet I provided you.

INITIAL CONDITIONS:

A LOCA occurred on Unit 1.

Both VX fans failed to operate.

EP/1/A15000/ES-1.3 (Transfer to Cold Leg Recirculation) is in progress.

NS Pumps have just been secured per Step 6.

INITIATING CUES:

Perform Enclosure 2 (Aligning NS for Recirculation) of EP/1/A15000/ES-1.3.

JPM09 B Page 4 of 11 READ TO OPERATOR DIRECTION TO TRAINEE:

I will explain the initial conditions, and state the task to be performed. All control room steps shall be performed for this JPM, including any required communications. I will provide initiating cues and reports on other actions when directed by you. Ensure you indicate to me when you understand your assigned task. To indicate that you have completed your assigned task return the handout sheet I provided you.

INITIAL CONDITIONS:

A LOCA occurred on Unit 1.

80th VX fans failed to operate.

EP/1/A/5000/ES-1.3 (Transfer to Cold Leg Recirculation) is in progress.

NS Pumps have just been secured per Step 6.

INITIATING CUES:

Perform Enclosure 2 (Aligning NS for Recirculation) of EP/1/A/5000/ES-1.3.

JPM098 Page 4 of 11

START TIME: __

STEP 1:

CRITICAL STEP Close the following valves 1 NS-20A (NS Pump 1A Suet From FWST)

SAT 1 NS-3B (NS Pump 1 B Suct From FWST)

STANDARD:

Determines 1 NS-20A will not close. Depresses GREEN UNSAT

'CLOSE' pushbuttons for 1 NS-3B. Verifies GREEN 'CLSD' light lit and RED 'OPEN' light dark.

COMMENTS:

STEP 2:

Verify at least one of the following annunciators - LIT SAT 1AD-20, B/3 "CONT SUMP LEVEL> 3.3ft" OR 1AD-21, B/3 "CONT SUMP LEVEL> 3.3ft" UNSAT STANDARD:

Determines both lights are lit.

COMMENTS:

JPM08 B Page 5 of 11 START TIME: __

STEP 1:

CRITICAL STEP Close the following valves 1 NS-20A (NS Pump 1A Suct From FWST)

SAT 1 NS-38 (NS Pump 18 Suct From FWST)

STANDARD:

Determines 1 NS-20A will not close. Depresses GREEN UNSAT

'CLOSE' pushbuttons for 1 NS-38. Verifies GREEN 'CLSD' light lit and RED 'OPEN' light dark.

COMMENTS:

STEP 2:

Verify at least one of the following annunciators - LIT SAT 1AD-20, 8/3 "CONT SUMP LEVEL> 3.3ft" OR 1AD-21, 8/3 "CONT SUMP LEVEL> 3.3ft" UNSAT STANDARD:

Determines both lights are lit.

COMMENTS:

JPM088 Page 5 of 11

STEP 3:

Verify both NS trains - AVAILABLE FOR SERVICE.

SAT STANDARD:

Student may say that A train is available based on ability to align to the FWST and continue to step 4, however step 4b will not be met and the student will transition to Step 6 either UNSAT at this time or when step 4b is read.

COMMENTS STEP 3 RNO:

IF NS Train 1 B available, THEN GO TO step 6.

SAT STANDARD: Determines 1 B is available and goes to step 6 AlER column.

UNSAT COMMENTS STEP 6a:

Align NS Train 1 B as follows:

SAT

a. Verify 1NI-184B (NO Pump 1B Cont Sump Suct) - OPEN.

STANDARD: Verifies RED 'OPEN' light lit and GREEN "CLSD' light dark.

UNSAT COMMENTS JPM08 B Page 6 of 11 STEP 3:

Verify both NS trains - AVAILABLE FOR SERVICE.

SAT STANDARD:

Student may say that A train is available based on ability to align to the FWST and continue to step 4, however step 4b will not be met and the student will transition to Step 6 either UNSAT at this time or when step 4b is read.

COMMENTS STEP 3 RNO:

IF NS Train 1 B available, THEN GO TO step 6.

SAT STANDARD: Determines 1 B is available and goes to step 6 AlER column.

UNSAT COMMENTS STEP 6a:

Align NS Train 1 B as follows:

SAT

a. Verify 1 NI-184B (ND Pump 1 B Cont Sump Suct) - OPEN.

STANDARD: Verifies RED 'OPEN' light lit and GREEN "CLSD' light dark.

UNSAT COMMENTS JPM08 B Page 6 of 11

STEP 6b:

Verify 1 NS-3B (NS Pump 1 B Suet from FWST) - CLOSED.

STANDARD: Verifies GREEN "CLSD' light lit and RED 'OPEN' light dark COMMENTS STEP 6e:

Open 1 NS-1 B (NS Pmp B Suet From Cont Sump).

STANDARD: Depresses RED open pushbutton and verifies RED 'OPEN' light lit and GREEN 'Closed' light dark.

COMMENTS STEP 6d:

Ensure the following valves - OPEN:

1 NS-15B (NS Spray Hdr 1 B Cont Isol) 1 NS-12B (NS Spray Hdr 1 B Cont Isol)

STANDARD: Verifies RED 'OPEN' lights lit and GREEN 'CLOSED' lights dark..

COMMENTS JPM08 B SAT UNSAT CRITICAL STEP SAT UNSAT SAT UNSAT Page 7 of 11 STEP 6b:

Verify 1 NS-3B (NS Pump 1 B Suet from FWST) - CLOSED.

STANDARD: Verifies GREEN "CLSD' light lit and RED 'OPEN' light dark COMMENTS STEP 6e:

Open 1 NS-1 B (NS Pmp B Suet From Cont Sump).

STANDARD: Depresses RED open pushbutton and verifies RED 'OPEN' light lit and GREEN 'Closed' light dark.

COMMENTS STEP 6d:

Ensure the following valves - OPEN:

1 NS-15B (NS Spray Hdr 1 B Cont Isol) 1 NS-12B (NS Spray Hdr 1 B Cont Isol)

STANDARD: Verifies RED 'OPEN' lights lit and GREEN 'CLOSED' lights dark..

COMMENTS JPM08 B SAT UNSAT CRITICAL STEP SAT UNSAT SAT UNSAT Page 7 of 11

STEP 7:

Verifies containment pressure - HAS EXCEEDED 3 PSIG STANDARD: Determines containment pressure has exceeded 3 PSIG since NS has actuated and Phase B reset lights are dark.

Can also check chart recorder of containment pressure.

COMMENTS STEP 8:

Verify Containment pressure - GREATER THAN 1 PSIG.

STANDARD:

Verifies containment pressure is 1

psig using 1 NSP5040/5050/5060/5070 (1 MC-11), or 1 NCCR5040/5390 (pen 1) or 1 MICR5340/5350 (pen 3) or OAC indication.

COMMENTS STEP 9:

Ensure NS pump(s) aligned to an open containment suction valve - ON.

STANDARD: Determines GREEN 'OFF' light is lit. Depresses RED 'ON' pushbutton and verifies 1 B NS pump starts.

EXAMINER NOTE: The 1 B NS pump should have auto started, but auto start was blocked.

COMMENTS STEP 10:

Verify all Unit 1 and Unit 2 RN pumps - ON STANDARD: Verifies RED 'ON' Lights lit and GREEN 'OFF' lights dark for all unit 1 and unit 2 RN pumps.

COMMENTS JPM08 B SAT UNSAT SAT UNSAT CRITICAL STEP SAT UNSAT SAT UNSAT Page 8 of 11 STEP 7:

Verifies containment pressure - HAS EXCEEDED 3 PSIG STANDARD: Determines containment pressure has exceeded 3 PSIG since NS has actuated and Phase B reset lights are dark.

Can also check chart recorder of containment pressure.

COMMENTS STEP 8:

Verify Containment pressure - GREATER THAN 1 PSIG.

STANDARD:

Verifies containment pressure is 1

psig using 1 NSP5040/5050/5060/5070 (1 MC-11), or 1 NCCR5040/5390 (pen 1) or 1 MICR5340/5350 (pen 3) or OAC indication.

COMMENTS STEP 9:

Ensure NS pump(s) aligned to an open containment suction valve - ON.

STANDARD: Determines GREEN 'OFF' light is lit. Depresses RED 'ON' pushbutton and verifies 1 B NS pump starts.

EXAMINER NOTE: The 1 B NS pump should have auto started, but auto start was blocked.

COMMENTS STEP 10:

Verify all Unit 1 and Unit 2 RN pumps - ON STANDARD: Verifies RED 'ON' Lights lit and GREEN 'OFF' lights dark for all unit 1 and unit 2 RN pumps.

COMMENTS JPM08 B SAT UNSAT SAT UNSAT CRITICAL STEP SAT UNSAT SAT UNSAT Page 8 of 11

CAUTION: Exceeding 4650 GPM RN flow through an NS Hx will cause damage to the Hx tubes.

STANDARD: Acknowledges caution.

COMMENTS STEP 11a:

Align RN to NS Hx(s) as follows:

a. Open 1RN-144A (NS Hx 1A Inlet Isol)

STANDARD: Depresses the RED 'OPEN' pushbutton for 1RN-144A COMMENTS STEP 11b:

WHEN 1RN144A begins to open, THEN throttle open 1RN-148A (NS Hx 1A Otlt Isol) to obtain one of the following:

4500 GPM flow through NS Hx 1A OR 1RN-148A full open STANDARD: Begins to throttle open 1RN-148A to obtain 4500 gpm OR 1RN-148A full open.

COMMENTS STEP 11c:

Open 1 RN-225B (NS Hx 1 B Inlet Isol)

STANDARD: Depresses the RED 'OPEN' pushbutton for 1 RN-225B.

COMMENTS JPM08 B SAT UNSAT SAT UNSAT SAT UNSAT CRITICAL STEP SAT UNSAT Page 9 of 11 CAUTION: Exceeding 4650 GPM RN flow through an NS Hx will cause damage to the Hx tubes.

STANDARD: Acknowledges caution.

COMMENTS STEP 11a:

Align RN to NS Hx(s) as follows:

a. Open 1 RN-144A (NS Hx 1A Inlet Isol)

STANDARD: Depresses the RED 'OPEN' pushbutton for 1RN-144A COMMENTS STEP 11b:

WHEN 1 RN144A begins to open, THEN throttle open 1 RN-148A (NS Hx 1A Otlt Isol) to obtain one of the following:

4500 GPM flow through NS Hx 1A OR 1 RN-148A full open STANDARD: Begins to throttle open 1 RN-148A to obtain 4500 gpm OR 1 RN-148A full open.

COMMENTS STEP 11c:

Open 1 RN-225B (NS Hx 1 B Inlet Isol)

STANDARD: Depresses the RED 'OPEN' pushbutton for 1 RN-225B.

COMMENTS JPM08 B SAT UNSAT SAT UNSAT SAT UNSAT CRITICAL STEP SAT UNSAT Page 9 of 11

STEP 11d:

WHEN 1 RN225B begins to open, THEN throttle open 1 RN-229B (NS Hx 1 B Otlt Isol) to obtain one of the following:

4500 GPM flow through NS Hx 1 A OR 1 RN-229B full open STANDARD: Begins to throttle open 1RN-229B to obtain 4500 gpm OR 1 RN-229B full open.

COMMENTS STEP 11e:

GO TO step 13 STANDARD: Goes to step 13 COMMENTS STEP 13:

Verify adequate RN heat sink as follows:

RN System - SUCTION ALIGNED TO LAKE WYLIE RN essential header temperature at one of the following locations - LESS THAN OR EQUAL TO 93°F o

1MC-9 OR o

RO Logbook STANDARD: Verifies the RED 'OPEN lights lit and the GREEN 'CLOSED' lights dark for 1RN-1A, 1RN-2B, 1RN-5A, and 1RN6B Verifies RN essential temp on 1 MC-9 < 93°F using 1RNP5000 or 1RNP5010 (1 MC-9) or request RN temp from RO Logbook.

EXAMINER CUE: If asked, state: "RO Logbook indicates essential header temp is 70°F."

COMMENTS This JPM is comQlete.

TIME STOP: __

JPM08 B CRITICAL STEP SAT UNSAT SAT

_UNSAT SAT UNSAT Page 10 of 11 STEP 11d:

WHEN 1 RN225B begins to open, THEN throttle open 1 RN-229B (NS Hx 1 B Otlt Isol) to obtain one of the following:

4500 GPM flow through NS Hx 1A OR 1 RN-229B full open STANDARD: Begins to throttle open 1 RN-229B to obtain 4500 gpm OR 1 RN-229B full open.

COMMENTS STEP 11e:

GO TO step 13 STANDARD: Goes to step 13 COMMENTS STEP 13:

Verify adequate RN heat sink as follows:

RN System - SUCTION ALIGNED TO LAKE WYLIE RN essential header temperature at one of the following locations - LESS THAN OR EQUAL TO 93°F o

1 MC-9 OR o

RO Logbook STANDARD: Verifies the RED 'OPEN lights lit and the GREEN 'CLOSED' lights dark for 1 RN-1 A, 1 RN-2B, 1 RN-5A, and 1 RN6B Verifies RN essential temp on 1 MC-9 < 93°F using 1 RNP5000 or 1 RNP501 0 (1 MC-9) or request RN temp from RO Logbook.

EXAMINER CUE:

If asked, state: "RO Logbook indicates essential header temp is 70°F."

COMMENTS This JPM is complete.

TIME STOP: __

JPM08 B CRITICAL STEP SAT UNSAT SAT UNSAT SAT UNSAT Page 10 of 11

CANDIDATE CUE SHEET (TO BE RETURNED TO EXAMINER UPON COMPLETION OF TASK)

INITIAL CONDITIONS:

A LOCA occurred on Unit 1.

Both VX fans failed to operate.

EP/1/A/5000/ES-1.3 (Transfer to Cold Leg Recirculation) is in progress.

NS Pumps have just been secured per Step 6.

INITIATING CUES:

Perform Enclosure 2 (Aligning NS for Recirculation) of EP/1/A/5000/ES-1.3.

CANDIDATE CUE SHEET (TO BE RETURNED TO EXAMINER UPON COMPLETION OF TASK)

INITIAL CONDITIONS:

A LOCA occurred on Unit 1.

Both VX fans failed to operate.

EP/1/A/5000/ES-1.3 (Transfer to Cold Leg Recirculation) is in progress.

NS Pumps have just been secured per Step 6.

INITIATING CUES:

Perform Enclosure 2 (Aligning NS for Recirculation) of EP/1/A/5000/ES-1.3.

CNS TRANSFER TO COLD LEG RECIRCULATION PAGE NO.

EP/1/N5000/ES-1.3 - Page 1 of 13 21 of 38 Revision 21 Aligning NS for Recirculation ACTION/EXPECTED RESPONSE

1.

Close the following valves:

  • 1 NS-20A (NS Pump 1A Suct From FWST)
  • 1 NS-38 (NS Pump 18 Suct From FWST).
2.

Verify at least one of the following annunciators - LIT:

_. 1AD-20, 8/3 "CONT. SUMP LEVEL >3.3 ft" OR

3.

Verify both NS trains - AVAILABLE FOR SERVICE.

RESPONSE NOT OBTAINED Perform the following:

a. WHEN at least one "CO NT. SUMP LEVEL >3.3 ft" annunciator is LIT, THEN GO TO Step 3.
b. Do not continue in this enclosure until at least one annuciator is LIT.

Perform the following:

a. IF NS Train 1A is available, THEN GO TO Step 5.
b. IF NS Train 18 is available, THEN GO TO Step 6.

CNS TRANSFER TO COLD LEG RECIRCULATION PAGE NO.

EP/1/A/5000/ES-1.3 - Page 1 of 13 21 of 38 Revision 21 Aligning NS for Recirculation ACTION/EXPECTED RESPONSE

1.

Close the following valves:

  • 1 NS-20A (NS Pump 1A Suct From FWST)
  • 1 NS-38 (NS Pump 18 Suct From FWST).
2.

Verify at least one of the following annunciators - LIT:

_. 1AD-20, 8/3 "CO NT. SUMP LEVEL >3.3 ft" OR

3.

Verify both NS trains - AVAILABLE FOR SERVICE.

RESPONSE NOT OBTAINED Perform the following:

a. WHEN at least one "CO NT. SUMP LEVEL >3.3 ft" annunciator is LIT, THEN GO TO Step 3.
b. Do not continue in this enclosure until at least one annuciator is LIT.

Perform the following:

a. IF NS Train 1A is available, THEN GO TO Step 5.
b. IF NS Train 18 is available, THEN GO TO Step 6.

CNS TRANSFER TO COLD LEG RECIRCULATION PAGE NO.

EP/1/A/5000/ES-1.3 - Page 2 of 13 22 of 38 Revision 21 Aligning NS for Recirculation ACTION/EXPECTED RESPONSE

4.

Align NS as follows:

a. Verify the following valves - OPEN:
  • 1 NI-185A (NO Pump 1A Cont Sump Suct)
b. Verify 1 NS-20A (NS Pump 1A Suct From FWST) - CLOSED.
c. Open 1 NS-18A (NS Pmp A Suct From Cont Sump).
d. Verify 1 NS-3B (NS Pump 1 B Suct From FWST) - CLOSED.
e. Open 1 NS-1 B (NS Pmp B Suct From Cont Sump).
f.

Ensure the following valves - OPEN:

  • 1 NS-29A (NS Spray Hdr 1 A Cont Isol)
  • 1 NS-32A (NS Spray Hdr 1A Cont Isol)
  • 1NS-15B (NS Spray Hdr 1B Cont Isol)
  • 1 NS-12B (NS Spray Hdr 1 B Cont Isol).

_ g. GO TO Step 7.

RESPONSE NOT OBTAINED

a. Perform the following:

_ 1) IF 1NI-185A closed, THEN GO TO Step 6.

_ 2) IF 1NI-184B closed, THEN GO TO Step 5.

b. GO TO Step 6.
d. GO TO Step 5.

CNS TRANSFER TO COLD LEG RECIRCULATION PAGE NO.

EP/1/A/5000/ES-1.3 - Page 2 of 13 22 of 38 Revision 21 Aligning NS for Recirculation ACTION/EXPECTED RESPONSE

4.

Align NS as follows:

a. Verify the following valves - OPEN:
b. Verify 1 NS-20A (NS Pump 1A Suct From FWST) - CLOSED.
c. Open 1 NS-18A (NS Pmp A Suct From Cant Sump).
d. Verify 1 NS-3B (NS Pump 1 B Suct From FWST) - CLOSED.
e. Open 1 NS-1 B (NS Pmp B Suct From Cant Sump).
f.

Ensure the following valves - OPEN:

  • 1 NS-29A (NS Spray Hdr 1A Cant Isol)
  • 1 NS-32A (NS Spray Hdr 1A Cant Isol)
  • 1 NS-15B (NS Spray Hd r 1 B Cant Isol)
  • 1NS-12B (NS Spray Hdr 1B Cant Isol).

_ g. GO TO Step 7.

RESPONSE NOT OBTAINED

a. Perform the following:

_ 1) IF 1NI-185A closed, THEN GO TO Step 6.

_ 2) IF 1NI-184B closed, THEN GO TO Step 5.

b. GO TO Step 6.
d. GO TO Step 5.

CNS TRANSFER TO COLD LEG RECIRCULATION EP/1/A15000/ES-1.3 - Page 3 of 13 Aligning NS for Recirculation ACTION/EXPECTED RESPONSE

5.

Align NS Train 1A as follows:

a. Verify 1 NI-185A (ND Pump 1A Cont Sump Suet) - OPEN.
b. Verify 1 NS-20A (NS Pump 1A Suet From FWST) - CLOSED.
e. Open 1 NS-18A (NS Pmp A Suet From Cont Sump).
d. Ensure the following valves - OPEN:
  • 1 NS-29A (NS Spray Hdr 1 A Cont 1501)
  • 1 NS-32A (NS Spray Hdr 1A Cont 1501).

_ e. GO TO Step 7.

6.

Align NS Train 1 B as follows:

a. Verify 1NI-1848 (ND Pump 18 Cont Sump Suet) - OPEN.
b. Verify 1 NS-38 (NS Pump 18 Suet From FWST) - CLOSED.
e. Open 1 NS-18 (NS Pmp 8 Suet From Cont Sump).
d. Ensure the following valves - OPEN:
  • 1 NS-158 (NS Spray Hdr 18 Cont 1501)
  • 1 NS-128 (NS Spray Hdr 18 Cont 1501).
7.

Verify containment pressure - HAS EXCEEDED 3 PSIG.

RESPONSE NOT OBTAINED

a. GO TO Step 6.
b. GO TO Step 6.
a. GO TO Step 5.
b. GO TO Step 5.

GO TO Step 10.

PAGE NO.

23 of 38 Revision 21 CNS TRANSFER TO COLD LEG RECIRCULATION EP/1/A/5000/ES-1.3 - Page 3 of 13 Aligning NS for Recirculation ACTION/EXPECTED RESPONSE

5.

Align NS Train 1A as follows:

a. Verify 1 NI-185A (NO Pump 1A Cant Sump Suet) - OPEN.
b. Verify 1 NS-20A (NS Pump 1A Suet From FWST) - CLOSED.
c. Open 1 NS-18A (NS Pmp A Suet From Cant Sump).
d. Ensure the following valves - OPEN:
  • 1 NS-29A (NS Spray Hdr 1 A Cant Isol)
  • 1 NS-32A (NS Spray Hdr 1 A Cant Isol).

_ e. GO TO Step 7.

6.

Align NS Train 1 B as follows:

a. Verify 1NI-1848 (NO Pump 18 Cant Sump Suet) - OPEN.
b. Verify 1 NS-38 (NS Pump 18 Suet From FWST) - CLOSED.
c. Open 1 NS-1 8 (NS Pmp 8 Suet From Cant Sump).
d. Ensure the following valves - OPEN:
  • 1 NS-158 (NS Spray Hdr 18 Cant Isol)
  • 1 NS-128 (NS Spray Hdr 18 Cant Isol).
7.

Verify containment pressure - HAS EXCEEDED 3 PSIG.

RESPONSE NOT OBTAINED

a. GO TO Step 6.
b. GO TO Step 6.
a. GO TO Step 5.
b. GO TO Step 5.

_ GO TO Step 10.

PAGE NO.

23 of 38 Revision 21

CNS TRANSFER TO COLD LEG RECIRCULATION EP/1/A/SOOO/ES-1.3 - Page 4 of 13 Aligning NS for Recirculation ACTION/EXPECTED RESPONSE

8.

Verify containment pressure - GREATER THAN 1 PSIG.

9.

Ensure NS pump(s) aligned to an open containment sump suction valve - ON.

10.

Verify all Unit 1 and Unit 2 RN pumps -

ON.

RESPONSE NOT OBTAINED Perform the following:

a. Reset NS.
b. Stop NS pumps.
c. GO TO Step 10.

GO TO Step 12.

PAGE NO.

24 of 38 Revision 21 CNS TRANSFER TO COLD LEG RECIRCULATION EP/1/A/SOOO/ES-1.3 - Page 4 of 13 Aligning NS for Recirculation ACTION/EXPECTED RESPONSE

8.

Verify containment pressure - GREATER THAN 1 PSIG.

9.

Ensure NS pump(s) aligned to an open containment sump suction valve - ON.

10.

Verify all Unit 1 and Unit 2 RN pumps -

ON.

RESPONSE NOT OBTAINED Perform the following:

a. Reset NS.
b. Stop NS pumps.
c. GO TO Step 10.

_ GO TO Step 12.

PAGE NO.

24 of 38 Revision 21

CNS TRANSFER TO COLD LEG RECIRCULATION PAGE NO.

EP/1/A/5000/ES-1.3 - Page 5 of 13 25 of 38 Aligning NS for Recirculation Revision 21 ACTION/EXPECTED RESPONSE RESPONSE NOT OBTAINED CAUTION Exceeding 4650 GPM RN flow through an NS Hx will cause damage to the Hx tubes.

11.

Align RN to NS Hx(s) as follows:

a. Open 1RN-144A (NS Hx 1A Inlet 1501).
b. WHEN 1RN-144A begins to open, THEN throttle open 1RN-148A (NS Hx 1 A Otlt 1501) to obtain one of the following:

_

  • 4500 GPM flow through NS Hx 1A OR

_. 1 RN-148A full open.

c. Open 1 RN-225B (NS Hx 1 B Inlet 1501).
d. WHEN 1 RN-225B begins to open, THEN throttle open 1 RN-229B (NS Hx 1 B Otlt 1501) to obtain one of the following:
  • 4500 GPM flow through NS Hx 1 B OR

_. 1 RN-229B full open.

e. GO TO Step 13.

CNS TRANSFER TO COLD LEG RECIRCULATION PAGE NO.

EP/1/A/5000/ES-1.3 - Page 5 of 13 25 of 38 Aligning NS for Recirculation Revision 21 ACTION/EXPECTED RESPONSE RESPONSE NOT OBTAINED CAUTION Exceeding 4650 GPM RN flow through an NS Hx will cause damage to the Hx tubes.

11.

Align RN to NS Hx(s) as follows:

a. Open 1 RN-144A (NS Hx 1A Inlet Isol).
b. WHEN 1RN-144A begins to open, THEN throttle open 1RN-148A (NS Hx 1A Otlt Isol) to obtain one of the following:

_

  • 4500 GPM flow through NS Hx 1A OR

_. 1 RN-148A full open.

c. Open 1 RN-225B (NS Hx 1 B Inlet Isol).
d. WHEN 1 RN-225B begins to open, THEN throttle open 1 RN-229B (NS Hx 1 B Otlt Isol) to obtain one of the following:
  • 4500 GPM flow through NS Hx 1 B OR

_. 1 RN-229B full open.

e. GO TO Step 13.

CNS TRANSFER TO COLD LEG RECIRCULATION PAGE NO.

EP/1/Al5000/ES-1.3 - Page 6 of 13 26 of 38 Aligning NS for Recirculation Revision 21 ACTION/EXPECTED RESPONSE RESPONSE NOT OBTAINED CAUTION Exceeding 4650 GPM RN flow through an NS Hx will cause damage to the Hx tubes.

12.

Align RN to NS Hx(s) based on RN and NS pump status as follows:

a. Verify NS Pump 1A - ON.
a. Perform the following:
1) IF only one 8 Train RN pump is on, THEN close 2RN-4 7 A (RN Supply X-Over 1501).
2) IF only 8 Train RN pumps are on, THEN close one of the following valves:

_. 2RN-488 (RN Supply X-Over 1501)

OR

_. 2RN-47A (RN Supply X-Over 1501).

_ 3) Open 1 RN-2258 (NS Hx 18 Inlet 1501).

4) WHEN 1RN-2258 begins to open, THEN throttle open 1 RN-2298 (NS Hx 18 Otlt 1501) to obtain one of the following:

_. 4500 GPM flow through NS Hx 18 OR

_. 1 RN-2298 full open.

_ 5) GO TO Step 13.

CNS TRANSFER TO COLD LEG RECIRCULATION PAGE NO.

EP/1/A/5000/ES-1.3 - Page 6 of 13 26 of 38 Aligning NS for Recirculation Revision 21 ACTION/EXPECTED RESPONSE RESPONSE NOT OBTAINED CAUTION Exceeding 4650 GPM RN flow through an NS Hx will cause damage to the Hx tubes.

12.

Align RN to NS Hx(s) based on RN and NS pump status as follows:

a. Verify NS Pump 1A - ON.
a. Perform the following:

_ 1) IF only one 8 Train RN pump is on, THEN close 2RN-47A (RN Supply X-Over Isol).

2) IF only 8 Train RN pumps are on, THEN close one of the following valves:

_. 2RN-488 (RN Supply X-Over Isol)

OR

_. 2RN-47A (RN Supply X-Over Isol).

_ 3) Open 1 RN-2258 (NS Hx 18 Inlet Isol).

4) WHEN 1 RN-2258 begins to open, THEN throttle open 1 RN-2298 (NS Hx 18 Otlt Isol) to obtain one of the following:

_

  • 4500 GPM flow through NS Hx 18 OR

_. 1 RN-2298 full open.

_ 5) GO TO Step 13.

CNS TRANSFER TO COLD LEG RECIRCULATION PAGE NO.

EP/1/A/5000/ES-1.3 - Page 7 of 13 27 of 38 Aligning NS for Recirculation Revision 21 ACTION/EXPECTED RESPONSE

12. (Continued)
b. Verify NS Pump 1 B - ON.

RESPONSE NOT OBTAINED

b. Perform the following:
1) IF only one A Train RN pump is on, THEN close 2RN-48B (RN Supply X-Over Isol).
2) IF only A Train RN pumps are on, THEN close one of the following valves:

_. 2RN-47A (RN Supply X-Over Isol)

OR

_. 2RN-48B (RN Supply X-Over Isol).

3) Open 1 RN-144A (NS Hx 1A Inlet Isol).
4) WHEN 1RN-144A begins to open, THEN throttle open 1 RN-148A (NS Hx 1 A Otlt Isol) to obtain one of the following:
  • 4500 GPM flow through NS Hx 1A OR

_. 1RN-148A full open.

5) GO TO Step 13.

CNS TRANSFER TO COLD LEG RECIRCULATION PAGE NO.

EP/1/A/5000/ES-1.3 - Page 7 of 13 27 of 38 Aligning NS for Recirculation Revision 21 ACTION/EXPECTED RESPONSE

12. (Continued)
b. Verify NS Pump 1 B - ON.

RESPONSE NOT OBTAINED

b. Perform the following:
1) IF only one A Train RN pump is on, THEN close 2RN-48B (RN Supply X-Over Isol).
2) IF only A Train RN pumps are on, THEN close one of the following valves:

_. 2RN-47 A (RN Supply X-Over Isol)

OR

_ 3) Open 1 RN-144A (NS Hx 1A Inlet Isol).

4) WHEN 1RN-144A begins to open, THEN throttle open 1 RN-148A (NS Hx 1A Otlt Isol) to obtain one of the following:
  • 4500 GPM flow through NS Hx 1A OR

_. 1 RN-148A full open.

_ 5) GO TO Step 13.

CNS TRANSFER TO COLD LEG RECIRCULATION PAGE NO.

EP/1/A/5000/ES-1.3 - Page 8 of 13 28 of 38 Revision 21 Aligning NS for Recirculation ACTION/EXPECTED RESPONSE

12. (Continued)
c. Verify at least one A Train RN pump -

ON.

RESPONSE NOT OBTAINED

c. Perform the following:
1) IF both B Train RN pumps are on, THEN close one of the following valves:

OR

_. 2RN-48B (RN Supply X-Over Isol).

_ 2) IF only one B Train RN pump is on, THEN close 2RN-47A (RN Supply X-Over Isol).

_ 3) Open 1 RN-225B (NS Hx 1 B Inlet Isol).

4) WHEN 1 RN-225B begins to open, THEN throttle open 1 RN-229B (NS Hx 1 B Otlt Isol) to obtain one of the following:
  • 4500 GPM flow through NS Hx 1B OR

_. 1 RN-229B full open.

_ 5) GO TO Step 13.

CNS TRANSFER TO COLD LEG RECIRCULATION PAGE NO.

EP/1/A/5000/ES-1.3 - Page 8 of 13 28 of 38 Revision 21 Aligning NS for Recirculation ACTION/EXPECTED RESPONSE

12. (Continued)
c. Verify at least one A Train RN pump -

ON.

RESPONSE NOT OBTAINED

c. Perform the following:
1) IF both B Train RN pumps are on, THEN close one of the following valves:

OR

_. 2RN-48B (RN Supply X-Over 1501).

_ 2) IF only one B Train RN pump is on, THEN close 2RN-47A (RN Supply X-Over 1501).

_ 3) Open 1 RN-225B (NS Hx 1 B Inlet 1501).

4) WHEN 1RN-225B begins to open, THEN throttle open 1 RN-229B (NS Hx 1 B Otlt 1501) to obtain one of the following:
  • 4500 GPM flow through NS Hx 1B OR

_. 1 RN-229B full open.

_ 5) GO TO Step 13.

CNS TRANSFER TO COLD LEG RECIRCULATION PAGE NO.

EP/1/A15000/ES-1.3 - Page 9 of 13 29 of 38 Revision 21 Aligning NS for Recirculation ACTION/EXPECTED RESPONSE

12. (Continued)
d. Verify at least one B Train RN pump -

ON.

RESPONSE NOT OBTAINED

d. Perform the following:

1 ) IF both A Train RN pumps are on, THEN close one of the following valves:

_. 2RN-47 A (RN Supply X-Over Isol)

OR

_. 2RN-48B (RN Supply X-Over Isol).

_ 2) IF only one A Train RN pump is on, THEN close 2RN-48B (RN Supply X-Over Isol).

_ 3) Open 1 RN-144A (NS Hx 1A Inlet Isol).

4) WHEN 1RN-144A begins to open, THEN throttle open 1 RN-148A (NS Hx 1A Otlt Isol) to obtain one of the following:

_. 4500 GPM flow through NS Hx 1A OR

_. 1RN-148A full open.

_ 5) GO TO Step 13.

CNS TRANSFER TO COLD LEG RECIRCULATION PAGE NO.

EP/1/A15000/ES-1.3 - Page 9 of 13 29 of 38 Revision 21 Aligning NS for Recirculation ACTION/EXPECTED RESPONSE

12. (Continued)
d. Verify at least one 8 Train RN pump -

ON.

RESPONSE NOT OBTAINED

d. Perform the following:
1) IF both A Train RN pumps are on, THEN close one of the following valves:

_. 2RN-47A (RN Supply X-Over Isol)

OR

_. 2RN-488 (RN Supply X-Over Isol).

_ 2) IF only one A Train RN pump is on, THEN close 2RN-488 (RN Supply X-Over Isol).

_ 3) Open 1 RN-144A (NS Hx 1A Inlet Isol).

4) WHEN 1RN-144A begins to open, THEN throttle open 1 RN-148A (NS Hx 1A Otlt Isol) to obtain one of the following:
  • 4500 GPM flow through NS Hx 1A OR

_. 1 RN-148A full open.

_ 5) GO TO Step 13.

CNS TRANSFER TO COLD LEG RECIRCULATION PAGE NO.

EP/1/A/5000/ES-1.3 - Page 10 of 13 30 of 38 Aligning NS for Recirculation Revision 21 ACTION/EXPECTED RESPONSE RESPONSE NOT OBTAINED

12. (Continued)
e. Verify RN Pump 1A and 2A - ON.
e. Perform the following:
1) IF only one RN pump is on in each train, THEN align RN to only one NS Hx as follows:
  • NS Hx 1A:

_ a) Open 1 RN-144A (NS Hx 1A Inlet Isol).

b) WHEN 1 RN-144A begins to open, THEN throttle open 1 RN-148A (NS Hx 1A Otlt Isol) to obtain one of the following:

_

  • 4500 GPM flow through NS Hx 1A OR

_. 1RN-148A full open.

_ c) GO TO Step 13.

OR

  • NSHx1B:

_ a) Open 1 RN-225B (NS Hx 1 B Inlet Isol).

b) WHEN 1 RN-225B begins to open, THEN throttle open 1 RN-229B (NS Hx 1 B Otlt Isol) to obtain one of the following:

_. 4500 GPM flow through NS Hx 1B OR

_. 1 RN-229B full open.

_ c) GO TO Step 13.

(RNO continued on next page)

CNS TRANSFER TO COLD LEG RECIRCULATION PAGE NO.

EP/1/A/5000/ES-1.3 - Page 10 of 13 30 of 38 Aligning NS for Recirculation Revision 21 ACTION/EXPECTED RESPONSE RESPONSE NOT OBTAINED

12. (Continued)
e. Verify RN Pump 1A and 2A - ON.
e. Perform the following:
1) IF only one RN pump is on in each train, THEN align RN to only one NS Hx as follows:
  • NS Hx 1A:

_ a) Open 1 RN-144A (NS Hx 1A Inlet Isol).

b) WHEN 1 RN-144A begins to open, THEN throttle open 1 RN-148A (NS Hx 1A Otlt Isol) to obtain one of the following:

_

  • 4500 GPM flow through NS Hx 1A OR

_. 1RN-148A full open.

_ c) GO TO Step 13.

OR

  • NSHx1B:

_ a) Open 1 RN-225B (NS Hx 1 B Inlet Isol).

b) WHEN 1 RN-225B begins to open, THEN throttle open 1 RN-229B (NS Hx 1 B Otlt Isol) to obtain one of the following:

_. 4500 GPM flow through NS Hx 1B OR

_. 1 RN-229B full open.

c) GO TO Step 13.

(RNO continued on next page)

CNS TRANSFER TO COLD LEG RECIRCULATION PAGE NO.

EP/11A15000/ES-1.3 - Page 11 of 13 31 of 38 Revision 21 Aligning NS for Recirculation ACTION/EXPECTED RESPONSE

12. (Continued)
f.

Open 1RN-144A (NS Hx 1A Inlet Isol).

g. WHEN 1 RN-144A begins to open, THEN throttle open 1RN-148A (NS Hx 1 A Otlt Isol) to obtain one of the following:

_

  • 4500 GPM flow through NS Hx 1A OR
  • 1 RN-148A full open.

RESPONSE NOT OBTAINED

_ 2) Open 1 RN-225B (NS Hx 1 B Inlet Isol).

3) WHEN 1 RN-225B begins to open, THEN throttle open 1 RN-229B (NS Hx 1 B Otlt Isol) to obtain one of the following:

_

  • 4500 GPM flow through NS Hx 1B OR

_. 1 RN-229B full open.

_ 4) GO TO Step 13.

CNS TRANSFER TO COLD LEG RECIRCULATION PAGE NO.

EP/1/A/5000/ES-1.3 - Page 11 of 13 31 of 38 Revision 21 Aligning NS for Recirculation ACTION/EXPECTED RESPONSE

12. (Continued)
f.

Open 1RN-144A (NS Hx 1A Inlet Isol).

g. WHEN 1 RN-144A begins to open, THEN throttle open 1RN-148A (NS Hx 1 A Otlt Isol) to obtain one of the following:

_

  • 4500 GPM flow through NS Hx 1A OR
  • 1 RN-148A full open.

RESPONSE NOT OBTAINED

2) Open 1 RN-225B (NS Hx 1 B Inlet Isol).
3) WHEN 1 RN-225B begins to open, THEN throttle open 1 RN-229B (NS Hx 1 B Otlt Isol) to obtain one of the following:
  • 4500 GPM flow through NS Hx 1B OR

_. 1 RN-229B full open.

_ 4) GO TO Step 13.

CNS TRANSFER TO COLD LEG RECIRCULATION PAGE NO.

EP/1/A/5000/ES-1.3 - Page 12 of 13 32 of 38 Revision 21 Aligning NS for Recirculation ACTION/EXPECTED RESPONSE

13.

Verify adequate RN heat sink as follows:

  • RN System - SUCTION ALIGNED TO LAKE WYLIE
  • RN essential header temperatures at one of the following locations - LESS THAN OR EQUAL TO 93°F:
  • RO Logbook.

RESPONSE NOT OBTAINED Perform the following:

a. Ensure the following valves - OPEN:
  • 1 RN-3A (RN P/H Pit A Isol From SNSWP)
  • 1 RN-4B (RN P/H Pit B Isol From SNSWP)
  • 1 RN-58B (RN Hdr B Ret To SNSWP)
  • 1 RN-63A (RN Hdr A Ret To SNSWP)
  • 1 RN-846A (DIG 1A Hx Ret To SNSWP)
  • 1 RN-848B (DIG 1 B Hx Ret To SNSWP)

_. 2RN-848B (DIG 2B Hx Ret To SNSWP).

(RNO continued on next page)

CNS TRANSFER TO COLD LEG RECIRCULATION PAGE NO.

EP/1/A/5000/ES-1.3 - Page 12 of 13 32 of 38 Revision 21 Aligning NS for Recirculation ACTION/EXPECTED RESPONSE

13.

Verify adequate RN heat sink as follows:

  • RN System - SUCTION ALIGNED TO LAKE WYLIE
  • RN essential header temperatures at one of the following locations - LESS THAN OR EQUAL TO 93°F:
  • RO Logbook.

RESPONSE NOT OBTAINED Perform the following:

a. Ensure the following valves - OPEN:
  • 1 RN-3A (RN P/H Pit A Isol From SNSWP)
  • 1 RN-4B (RN P/H Pit B Isol From SNSWP)
  • 1 RN-58B (RN Hdr B Ret To SNSWP)
  • 1 RN-63A (RN Hdr A Ret To SNSWP)
  • 1 RN-846A (DIG 1A Hx Ret To SNSWP)
  • 1 RN-848B (DIG 1 B Hx Ret To SNSWP)

(RNO continued on next page)

CNS TRANSFER TO COLD LEG RECIRCULATION PAGE NO.

EP/1/A1S000/ES-1.3 - Page 13 of 13 33 of 38 Aligning NS for Recirculation Revision 21 ACTION/EXPECTED RESPONSE RESPONSE NOT OBTAINED

13. (Continued)
b. Ensure the following valves - CLOSED:
  • 1 RN-1A (RN P/H Pit A Isol From Lake)
  • 1 RN-2B (RN P/H Pit A Isol From Lake)
  • 1 RN-SA (RN P/H Pit B Isol From Lake)
  • 1 RN-6B (RN P/H Pit B Isol From Lake)
  • 1 RN-S3B (Station RN Disch Hdr X-Over)

_. 1 RN-S4A (Station RN Disch Hdr X-Over)

  • 1RN-S7A (Station RN Disch To RL Sys)
  • 1 RN-843B (Station RN Disch To RL Sys)
  • 1 RN-849B (DIG 1 B Hx Ret To Lake)

_. 2RN-847A (DIG 2A Hx Ret To Lake)

_. 2RN-849B (DIG 2B Hx Ret To Lake).

CNS TRANSFER TO COLD LEG RECIRCULATION PAGE NO.

EP/1/A/SOOO/ES-1.3 - Page 13 of 13 33 of 38 Aligning NS for Recirculation Revision 21 ACTION/EXPECTED RESPONSE RESPONSE NOT OBTAINED

13. (Continued)
b. Ensure the following valves - CLOSED:
  • 1 RN-1A (RN P/H Pit A Isol From Lake)
  • 1 RN-28 (RN P/H Pit A Isol From Lake)
  • 1 RN-SA (RN P/H Pit 8 Isol From Lake)
  • 1 RN-68 (RN P/H Pit 8 Isol From Lake)
  • 1 RN-S38 (Station RN Disch Hdr X-Over)
  • 1 RN-S4A (Station RN Disch Hdr X-Over)
  • 1 RN-S7A (Station RN Disch To RL Sys)
  • 1 RN-8438 (Station RN Disch To RL Sys)
  • 1 RN-847A (DIG 1A Hx Ret To Lake)
  • 1 RN-8498 (DIG 18 Hx Ret To Lake)

CATAWBA NUCLEAR STATION INITIAL LICENSE EXAMINATION JOB PERFORMANCE MEASURE JPM09 C Restore Offsite Power to 6.9 kV Busses per AP/07 (Loss of Normal Power) 1 (Black Restart Procedure)

CANDIDATE EXAMINER JPM09 C Page 1 of 12 CATAWBA NUCLEAR STATION INITIAL LICENSE EXAMINATION JOB PERFORMANCE MEASURE JPM09 C Restore Offsite Power to 6.9 kV Busses per AP/07 (Loss of Normal Power) 1 (Black Restart Procedure)

CANDIDATE EXAMINER JPM09 C Page 1 of 12

CATAWBA NUCLEAR STATION INITIAL LICENSE EXAMINATION JOB PERFORMANCE MEASURE Restore Offsite Power to 6.9Kv per AP/07 (Loss of Normal Power) Enclosure 21 (Black Restart Procedure)

Alternate Path:

Yes Facility JPM #:

BANK KIA Rating(s):

EPE055 EA 1.07 (4.3/4.5) Ability to operate and monitor the following as they apply to a Station Blackout - Restoration of power from offsite.

Task Standard:

Power has been restored to three 6.9 KV busses from the yellow buss via B train.

Preferred Evaluation Simulator:

Preferred Evaluation Perform Simulator X

In-Plant __ _

Perform _~X-,--

Simulate __ _

References:

AP/1/A/5500/007 (Loss of Normal Power) Enclosure 21 (Slack Start Procedure) rev 057 Validation Time: 18 min.

Time Critical: No

=======================================================================

Candidate:

Time Start:

NAME Time Finish:

Performance Rating:

SAT UNSAT Performance Time Examiner:

I NAME SIGNATURE DATE

=======================================================================

COMMENTS JPM09 C Page 2 of 12 CATAWBA NUCLEAR STATION INITIAL LICENSE EXAMINATION JOB PERFORMANCE MEASURE Restore Offsite Power to 6.9Kv per AP/O? (Loss of Normal Power) Enclosure 21 (Black Restart Procedure)

Alternate Path:

Yes Facility JPM #:

BANK KIA Rating(s):

EPE055 EA1.0? (4.3/4.5) Ability to operate and monitor the following as they apply to a Station Blackout - Restoration of power from offsite.

Task Standard:

Power has been restored to three 6.9 KV busses from the yellow buss via B train.

Preferred Evaluation Simulator:

Preferred Evaluation Perform Simulator X

In-Plant __ _

Perform _-,-X,,--

Simulate __ _

References:

AP/1/A/5500/007 (Loss of Normal Power) Enclosure 21 (Black Start Procedure) rev 057 Validation Time: 18 min.

Time Critical: No

=======================================================================

Candidate:

Time Start:

NAME Time Finish:

Performance Rating:

SAT UNSAT Performance Time Examiner:

I NAME SIGNATURE DATE

=======================================================================

COMMENTS JPM09 C Page 2 of 12

SIMULATOR SETUP SHEET

1. Reset to any 100% power IC set.
2. Place simulator in RUN.
3. Trip all Unit Tie PCBs.
4. Ensure turbine trips.
5. Perform appropriate actions of E-O and ES-0.1.
6. Perform actions of AP/11A155001007.
7. Perform actions of Enclosure 21 through step 11.
8. Allow simulator to run until the plant is stable.
9. Insert OVR-EP024B (PCB 18 TRIP TRIP PB), Value = ON, DELAY = 1 second, EVENT 1 10.Set EVENT 1 = JBKPCB18
11. Freeze, and write to a snap.

IC SELECTED ______ '

SIMULATOR OPERATOR INSTRUCTIONS:

None.

Tools/Equipment/Procedures Needed:

1. AP/11A15500107 (Loss of Normal Power) Enclosure 21 (Black Start Procedure) rev 057 JPM09 C Page 3 of 12 SIMULATOR SETUP SHEET
1. Reset to any 100% power IC set.
2. Place simulator in RUN.
3. Trip a" Unit Tie PCBs.
4. Ensure turbine trips.
5. Perform appropriate actions of E-O and ES-O.1.
6. Perform actions of AP/1/A/5500/007.
7. Perform actions of Enclosure 21 through step 11.
8. A"ow simulator to run until the plant is stable.
9. Insert OVR-EP024B (PCB 18 TRIP TRIP PB), Value = ON, DELAY = 1 second, EVENT 1 10.Set EVENT 1 = JBKPCB18
11. Freeze, and write to a snap.

IC SELECTED _____

SIMULATOR OPERATOR INSTRUCTIONS:

None.

Tools/Equipment/Procedures Needed:

1. AP/1/A/5500107 (Loss of Normal Power) Enclosure 21 (Black Start Procedure) rev 057 JPM09 C Page 3 of 12

READ TO OPERATOR DIRECTION TO TRAINEE:

I will explain the initial conditions, and state the task to be performed. All control room steps shall be performed for this JPM, including any required communications. I will provide initiating cues and reports on other actions when directed by you. Ensure you indicate to me when you understand your assigned task. To indicate that you have completed your assigned task return the handout sheet I provided you.

INITIAL CONDITIONS:

Both units experienced a loss of offsite power due to a Loss of Grid and AP/1/AJ55001007 (Loss of Normal Power) is in progress.

The TCC has reported that the Yellow Bus is energized and can be used on a limited basis to re-energize plant equipment.

AP/1/AJ55001007 Enclosure 21 has been completed through step 12.

INITIATING CUES:

The SRO instructs you to restore power to the Unit 1 6.9 KV Busses per Enclosure 21 (Black Start Procedure) of AP/1/AJ5500107 (Loss of Normal Power) starting at step 13.

JPM09 C Page 4 of 12 READ TO OPERATOR DIRECTION TO TRAINEE:

I will explain the initial conditions, and state the task to be performed. All control room steps shall be performed for this JPM, including any required communications. I will provide initiating cues and reports on other actions when directed by you. Ensure you indicate to me when you understand your assigned task. To indicate that you have completed your assigned task return the handout sheet I provided you.

INITIAL CONDITIONS:

Both units experienced a loss of offsite power due to a Loss of Grid and AP/1/A/5500/007 (Loss of Normal Power) is in progress.

The TCC has reported that the Yellow Bus is energized and can be used on a limited basis to re-energize plant equipment.

AP/1/A/5500/007 Enclosure 21 has been completed through step 12.

INITIATING CUES:

The SRO instructs you to restore power to the Unit 1 6.9 KV Busses per Enclosure 21 (Black Start Procedure) of AP/1/A/5500/07 (Loss of Normal Power) starting at step 13.

JPM09 C Page 4 of 12

START TIME: __

NOTE Zone A or B lockout will occur if at least one main transformer cooling circuit is not restored within 15 minutes of re-energizing the main transformer.

STEP 13: Energize A train as follows:

a. Contact TCC for permission to close PCB 18.

SAT STANDARD:

Calls TCC and requests permission.

INSTRUCTOR CUE: "You have permission to close PCB 18."

UNSAT EXAMINER NOTE: If the red phone is used, it will contact the SOC and the cue provided by the booth will be "This is the SOC; you need to contact the TCC at extension 3307."

COMMENTS:

STEP 13:

b. WHEN permission is granted, THEN close PCB 18.

SAT STANDARD:

Depresses the CLOSE pushbutton for PCB 18 and notes that the PCB 18 closes and then reopens in 1 second.

UNSAT COMMENTS:

STEP 13 RNO: b. IF PCB 18 cannot be closed, THEN perform the following:

1) Contact TCC for permission to energize Unit 1 B SAT train from the Yellow Bus.

STANDARD:

Calls TCC and requests permission.

UNSAT INSTRUCTOR CUE: "You have permission to energize B Train from the Yellow Bus."

EXAMINER NOTE: If the red phone is used, it will contact the SOC and the cue provided by the booth will be "This is the SOC; you need to contact the TCC at extension 3307."

COMMENTS JPM08 C Page 5 of 12 START TIME: __

NOTE Zone A or B lockout will occur if at least one main transformer cooling circuit is not restored within 15 minutes of re-energizing the main transformer.

STEP 13: Energize A train as follows:

a. Contact TCC for permission to close PCB 18.

SAT STANDARD:

Calls TCC and requests permission.

INSTRUCTOR CUE: "You have permission to close PCB 18."

UNSAT EXAMINER NOTE: If the red phone is used, it will contact the SOC and the cue provided by the booth will be "This is the SOC; you need to contact the TCC at extension 3307."

COMMENTS:

STEP 13:

b. WHEN permission is granted, THEN close PCB 18.

SAT STANDARD:

Depresses the CLOSE pushbutton for PCB 18 and notes that the PCB 18 closes and then reopens in 1 second.

UNSAT COMMENTS:

STEP 13 RNO: b. IF PCB 18 cannot be closed, THEN perform the following:

1) Contact TCC for permission to energize Unit 1 B SAT train from the Yellow Bus.

STANDARD:

Calls TCC and requests permission.

UNSAT INSTRUCTOR CUE: "You have permission to energize B Train from the Yellow Bus."

EXAMINER NOTE: If the red phone is used, it will contact the SOC and the cue provided by the booth will be "This is the SOC; you need to contact the TCC at extension 3307."

COMMENTS JPM08 C Page 5 of 12

STEP 13 RNO: b.2) WHEN permission granted, THEN perform the following:

a) Ensure MOD 1 B - CLOSED.

STANDARD: Determines MOD 1 B is closed on MC-11 COMMENTS STEP 13 RNO: b.2) WHEN permission granted, THEN perform the following:

b) Ensure PCB 14 - OPEN.

STANDARD: Ensures PCB 14 is OPEN COMMENTS STEP 13 RNO: b.2) WHEN permission granted, THEN perform the following:

c) Close PCB 15.

STANDARD: Closes PCB 15 from MC-11 COMMENTS STEP 13: c. Do not continue until one of the following PCBs is closed:

PCB 18 OR PCB 15.

STANDARD: Determines PCB 15 is closed.

COMMENTS NOTE:

Desired loading rate is 1-2 MW increments.

Total load per unit may be initially limited to approximately 11 MWs.

JPM08 C SAT UNSAT SAT UNSAT CRITICAL STEP SAT UNSAT SAT UNSAT Page 6 of 12 STEP 13 RNO: b.2) WHEN permission granted, THEN perform the following:

a) Ensure MOD 1 B - CLOSED.

STANDARD: Determines MOD 1 B is closed on MC-11 COMMENTS STEP 13 RNO: b.2) WHEN permission granted, THEN perform the following:

b) Ensure PCB 14 - OPEN.

STANDARD: Ensures PCB 14 is OPEN COMMENTS STEP 13 RNO: b.2) WHEN permission granted, THEN perform the following:

c) Close PCB 15.

STANDARD: Closes PCB 15 from MC-11 COMMENTS STEP 13: c. Do not continue until one of the following PCBs is closed:

PCB 18 OR PCB 15.

STANDARD: Determines PCB 15 is closed.

COMMENTS NOTE:

Desired loading rate is 1-2 MW increments.

Total load per unit may be initially limited to approximately 11 MWs.

JPM08 C SAT UNSAT SAT UNSAT CRITICAL STEP SAT UNSAT SAT UNSAT Page 6 of 12

STEP 14: IF "TRANSF 1A" energized, THEN perform the following:

STANDARD: Due to previous steps and plant condition should determine Transformer 1A is NOT energized and continue to next step.

COMMENTS STEP 15: IF "TRANSF 1B" energized, THEN perform the following:

a. Energize 1 TD as follows:
1) Place "7KV BUS 1 TD MODE SEL" switch in "MAN B&TIE".

STANDARD: Place lTD switch to Man B and tie.

COMMENTS STEP 15a: 2) Close "7KV 1 TD FDR FRM 1 T1 B".

STANDARD: Closes "7KV 1 TD FDR FRM 1 T1 B" COMMENTS STEP 15a: 3) Verify "7KV BUS 1TD TIE BKR" - CLOSED.

STANDARD: Verifies tie breaker closed on MC-11 COMMENTS JPM08 C SAT

_UNSAT CRITICAL STEP

_SAT

_UNSAT CRITICAL STEP SAT

_UNSAT SAT UNSAT Page 7 of 12 STEP 14: IF "TRANSF 1A" energized, THEN perform the following:

STANDARD: Due to previous steps and plant condition should determine Transformer 1A is NOT energized and continue to next step.

COMMENTS STEP 15: IF "TRANSF 1 B" energized, THEN perform the following:

a. Energize 1 TO as follows:
1) Place "7KV BUS 1TD MODE SEL" switch in "MAN B&TIE".

STANDARD: Place ITO switch to Man B and tie.

COMMENTS STEP 15a: 2) Close "7KV 1TD FOR FRM 1T1B".

STANDARD: Closes "7KV 1TD FOR FRM 1T1B" COMMENTS STEP 15a: 3) Verify "7KV BUS 1TD TIE BKR" - CLOSED.

STANDARD: Verifies tie breaker closed on MC-11 COMMENTS JPM08 C SAT

_UNSAT CRITICAL STEP SAT UNSAT CRITICAL STEP SAT

_UNSAT SAT UNSAT Page 7 of 12

STEP 15: b. Energize 1 TC as follows:

1) Verify with TCC that additional load can be accepted prior to energizing 6.9 KV bus.

STANDARD:

Calls TCC and requests permission.

INSTRUCTOR CUE: "Additional load can be accepted at this time."

EXAMINER NOTE: If the red phone is used, it will contact the SOC and the cue provided by the booth will be "This is the SOC; you need to contact the TCC at extension 3307."

COMMENTS STEP 15b: 2) Place "7KV BUS 1TC MODE SEL" switch in "MAN B & TIE".

STANDARD: Places 1TC in Man B and Tie position.

COMMENTS STEP 15b: 3) Close "7KV 1TC FOR FRM 1T2B".

STANDARD: Closes "7KV 1TC FOR FRM 1T2B" COMMENTS STEP 15b: 4) Verify "7KV BUS 1TC TIE BKR" - CLOSED.

STANDARD: Determines breaker is closed.

COMMENTS JPM08 C SAT UNSAT CRITICAL STEP SAT UNSAT CRITICAL STEP SAT UNSAT SAT UNSAT Page 8 of 12 STEP 15: b. Energize 1 TC as follows:

1) Verify with TCC that additional load can be accepted prior to energizing 6.9 KV bus.

STANDARD:

Calls TCC and requests permission.

INSTRUCTOR CUE: "Additional load can be accepted at this time."

EXAMINER NOTE: If the red phone is used, it will contact the SOC and the cue provided by the booth will be "This is the SOC; you need to contact the TCC at extension 3307."

COMMENTS STEP 15b: 2) Place "7KV BUS 1TC MODE SEL" switch in "MAN B & TIE".

STANDARD: Places 1TC in Man B and Tie position.

COMMENTS STEP 15b: 3) Close "7KV 1TC FDR FRM 1T2B".

STANDARD: Closes "7KV 1 TC FDR FRM 1 T2B" COMMENTS STEP 15b: 4) Verify "7KV BUS 1TC TIE BKR" - CLOSED.

STANDARD: Determines breaker is closed.

COMMENTS JPM08 C SAT UNSAT CRITICAL STEP SAT UNSAT CRITICAL STEP SAT UNSAT SAT UNSAT Page 8 of 12

STEP 15: c. Verify 1AD-11 F/2 "TRANSFORMER 1B FORCED COOLING REDUCTION" - DARK.

STANDARD: Determines the annunciator dark COMMENTS STEP 15: d. Energize 1TB as follows:

1) Verify with TCC that additional load can be accepted prior to energizing 6.9 KV bus STANDARD:

Calls TCC and requests permission.

INSTRUCTOR CUE: "Additional load can be accepted at this time."

EXAMINER NOTE: If the red phone is used, it will contact the SOC and the cue provided by the booth will be "This is the SOC; you need to contact the TCC at extension 3307."

COMMENTS STEP 15d: 2) Place "7KV BUS 1TB MODE SEL" switch in "MAN B & TIE".

STANDARD: Places 1TB in Man B and Tie COMMENTS STEP 15d: 3) Close "7KV 1TB FOR FRM 1T1B".

STANDARD: Closes "7KV 1TB FOR FRM 1T1B" COMMENTS JPM08 C SAT UNSAT SAT UNSAT CRITICAL STEP SAT UNSAT CRITICAL STEP SAT UNSAT Page 9 of 12 STEP 15: c. Verify 1AD-11 F/2 "TRANSFORMER 1 B FORCED COOLING REDUCTION" - DARK.

STANDARD: Determines the annunciator dark COMMENTS STEP 15: d. Energize 1TB as follows:

1) Verify with TCC that additional load can be accepted prior to energizing 6.9 KV bus STANDARD:

Calls TCC and requests permission.

INSTRUCTOR CUE: "Additional load can be accepted at this time."

EXAMINER NOTE: If the red phone is used, it will contact the SOC and the cue provided by the booth will be "This is the SOC; you need to contact the TCC at extension 3307."

COMMENTS STEP 15d: 2) Place "7KV BUS 1TB MODE SEL" switch in "MAN B & TIE".

STANDARD: Places 1TB in Man B and Tie COMMENTS STEP 15d: 3) Close "7KV 1TB FDR FRM 1T1B".

STANDARD: Closes "7KV 1TB FDR FRM 1T1B" COMMENTS JPM08 C SAT UNSAT SAT UNSAT CRITICAL STEP SAT UNSAT CRITICAL STEP SAT UNSAT Page 9 of 12

STEP 15d: 4) Verify "7KV BUS 1TB TIE BKR" - CLOSED.

STANDARD: Determines breaker is closed.

SAT COMMENTS UNSAT STEP 15: e. Energize 1TA as follows:

1) Verify with TCC that additional load can be accepted prior to energizing 6.9 KV bus.

SAT STANDARD:

Calls TeC and requests permission.

INSTRUCTOR CUE: "No additional loading should be attempted at UNSAT this time."

EXAMINER NOTE: If the red phone is used, it will contact the SOC and the cue provided by the booth will be "This is the SOC; you need to contact the TCC at extension 3307."

COMMENTS STEP 15e RNO: 1) Do not energize 1 TA until additional load can be accepted.

SAT STANDARD: Does NOT energize 1TA.

COMMENTS UNSAT STEP 15: f. Verify all 6.9 KV busses - ENERGIZED.

STANDARD: Determines "A" 6.9 KV is NOT energized and goes to RNO SAT COMMENTS UNSAT JPM08 C Page 10 of 12 STEP 15d: 4) Verify "7KV BUS 1TB TIE BKR" - CLOSED.

STANDARD: Determines breaker is closed.

SAT COMMENTS UNSAT STEP 15: e. Energize 1TA as follows:

1) Verify with TCC that additional load can be accepted prior to energizing 6.9 KV bus.

SAT STANDARD:

Calls TCC and requests permission.

INSTRUCTOR CUE: "No additional loading should be attempted at UNSAT this time."

EXAMINER NOTE: If the red phone is used, it will contact the SOC and the cue provided by the booth will be "This is the SOC; you need to contact the TCC at extension 3307."

COMMENTS STEP 15e RNO: 1) Do not energize 1 TA until additional load can be accepted.

SAT STANDARD: Does NOT energize 1TA.

COMMENTS UNSAT STEP 15: f. Verify all 6.9 KV busses - ENERGIZED.

STANDARD: Determines "A" 6.9 KV is NOT energized and goes to RNO SAT COMMENTS UNSAT JPM08 C Page 10 of 12

STEP 15f RNO: Perform the following:

1) IF waiting on TCe approval to energize additional 6.9 KV busses, THEN RETURN TO Step 15 and energize busses as TCC allows.

SAT STANDARD: Returns to Step 15.

EXAMINER CUE: Another Operator will complete the procedure.

UNSAT COMMENTS This JPM is complete.

TIME STOP: __

JPM08 e Page 11 of 12 STEP 15f RNO: Perform the following:

1) IF waiting on TCC approval to energize additional 6.9 KV busses, THEN RETURN TO Step 15 and energize busses as TCC allows.

SAT STANDARD: Returns to Step 15.

EXAMINER CUE: Another Operator will complete the procedure.

UNSAT COMMENTS This JPM is complete.

TIME STOP: __

JPM08 C Page 11 of 12

CANDIDATE CUE SHEET (TO BE RETURNED TO EXAMINER UPON COMPLETION OF TASK)

INITIAL CONDITIONS:

Both units experienced a loss of offsite power due to a Loss of Grid and AP/1/A/5500/007 (Loss of Normal Power) is in progress.

The TCC has reported that the Yellow Bus is energized and can by used on a limited basis to re-energize plant equipment.

AP/1/A/5500/007 Enclosure 21 has been completed through step 12.

INITIATING CUES:

The SRO instructs you to restore power to the Unit 1 6.9 KV Busses per Enclosure 21 (Black Start Procedure) of AP/1/A/5500/07 (Loss of Normal Power) starting at step 13.

CANDIDATE CUE SHEET (TO BE RETURNED TO EXAMINER UPON COMPLETION OF TASK)

INITIAL CONDITIONS:

Both units experienced a loss of offsite power due to a Loss of Grid and AP/11A155001007 (Loss of Normal Power) is in progress.

The TCC has reported that the Yellow Bus is energized and can by used on a limited basis to re-energize plant equipment.

AP/11A155001007 Enclosure 21 has been completed through step 12.

INITIATING CUES:

The SRO instructs you to restore power to the Unit 1 6.9 KV Busses per Enclosure 21 (Black Start Procedure) of AP/11A15500107 (Loss of Normal Power) starting at step 13.

I I

CNS LOSS OF NORMAL POWER PAGE NO.

AP 11/ AJ55001007 1 - Page 1 of 12 125 of 154 Black Start Procedure Revision 57 ACTION/EXPECTED RESPONSE RESPONSE NOT OBTAINED

1.

Ensure the following PCBs - OPEN:

  • PCB 14
  • PCB 15
  • PCB 17
  • PCB 18.
2.

Place the following pump switches in "OFF":

  • All hotwell pumps
  • All condensate booster pumps.
3.

Depress OFF on the following equipment:

  • KR Pump A
  • KR Pump B
  • KR Pump C.
4.

Dispatch operator to ensure breakers for all motor loads on all de-energized 6.9 KV busses open. REFER TO Enclosure 22 (Load Shed of 6.9 KV Busses).

5.

Dispatch operator to align 600 volt load centers for black start. REFER TO 5 (600 Volt Load Center Black Start Alignment).

6.

Ensure PZR HTR GROUP 1C - OFF.

7.

Place PZR HTR GROUP 1 D in "MAN" and "OFF".

8.

Shutdown the rod control system.

REFER TO OP/1/A16150/008 (Rod Control).

CNS LOSS OF NORMAL POWER AP/1 I Al55001007 1 - Page 1 of 12 Black Start Procedure ACTION/EXPECTED RESPONSE RESPONSE NOT OBTAINED

1.

Ensure the following PCBs - OPEN:

  • PCB 14
  • PCB 15
  • PCB 17
  • PCB 18.
2.

Place the following pump switches in "OFF":

  • All hotwell pumps
  • All condensate booster pumps.
3.

Depress OFF on the following equipment:

  • KR Pump A
  • KR Pump B
  • KR Pump C.
4.

Dispatch operator to ensure breakers for all motor loads on all de-energized 6.9 KV busses open. REFER TO Enclosure 22 (Load Shed of 6.9 KV Busses).

5.

Dispatch operator to align 600 volt load centers for black start. REFER TO 5 (600 Volt Load Center Black Start Alignment).

6.

Ensure PZR HTR GROUP 1C - OFF.

7.

Place PZR HTR GROUP 1D in "MAN" and "OFF".

8.

Shutdown the rod control system.

REFER TO OP/1/Al6150/o08 (Rod Control).

PAGE NO.

125 of 154 Revision 57

CNS LOSS OF NORMAL POWER PAGE NO.

AP/1/A/5500/007 1 - Page 2 of 12 126 of 154 Black Start Procedure Revision 57 ACTION/EXPECTED RESPONSE RESPONSE NOT OBTAINED The TCC black start procedure energizes plant auxiliaries via A Train Main Power from the Yellow Bus for both units.

9.

Verify with TCC - YELLOW BUS ENERGIZED.

10.

Ensure MOD 1A - CLOSED.

11.

Do not continue until the following conditions are met:

  • Rod control system is shutdown
  • Enclosure 22 (Load Shed of 6.9 KV Busses) is complete
  • Enclosure 25 (600 Volt Load Center Black Start Alignment) is complete.
12.

Coordinate energizing plant loads with Unit 2 to prevent over loading the grid.

Do not continue until the Yellow Bus energized.

CNS LOSS OF NORMAL POWER PAGE NO.

AP/1 / Al5500/007 1 - Page 2 of 12 Black Start Procedure ACTION/EXPECTED RESPONSE RESPONSE NOT OBTAINED The TCC black start procedure energizes plant auxiliaries via A Train Main Power from the Yellow Bus for both units.

126 of 154 Revision 57

9.

Verify with TCC - YELLOW BUS ENERGIZED.

Do not continue until the Yellow Bus energized.

10.

Ensure MOD 1A - CLOSED.

11.

Do not continue until the following conditions are met:

  • Rod control system is shutdown
  • Enclosure 22 (Load Shed of 6.9 KV Busses) is complete
  • Enclosure 25 (600 Volt Load Center Black Start Alignment) is complete.
12.

Coordinate energizing plant loads with Unit 2 to prevent over loading the grid.

CNS LOSS OF NORMAL POWER PAGE NO.

AP 111 Al55001007 1 - Page 3 of 12 127 of 154 Revision 57 Black Start Procedure ACTION/EXPECTED RESPONSE RESPONSE NOT OBTAINED Zone A or B lockout wi" occur if at least one main transformer cooling circuit is not restored within 15 minutes of re-energizing the main transformer.

13.

Energize A train as follows:

a. Contact TCC for permission to close PCB 18.
b. WHEN permission granted, THEN close PCB 18.
c. Do not continue until one of the following PCBs is closed:
  • PCB 15.
b. IF PCB 18 cannot be closed, THEN perform the following:

_ 1) Contact TCC for permission to energize Unit 1 B train from the Yellow Bus.

2) WHEN permission granted, THEN perform the following:

_ a) Ensure MOD 1 B - CLOSED.

_ b) Ensure PCB 14 - OPEN.

_ c) Close PCB 15.

CNS LOSS OF NORMAL POWER PAGE NO.

AP/1/N5500/007 1 - Page 3 of 12 127 of 154 Revision 57 Black Start Procedure ACTION/EXPECTED RESPONSE RESPONSE NOT OBTAINED Zone A or B lockout wi" occur if at least one main transformer cooling circuit is not restored within 15 minutes of re-energizing the main transformer.

13.

Energize A train as follows:

a. Contact TCC for permission to close PCB 18.
b. WHEN permission granted, THEN close PCB 18.
c. Do not continue until one of the following PCBs is closed:
  • PCB 15.
b. IF PCB 18 cannot be closed, THEN perform the following:

_ 1) Contact TCC for permission to energize Unit 1 B train from the Yellow Bus.

2) WHEN permission granted, THEN perform the following:

_ a) Ensure MOD 1 B - CLOSED.

_ b) Ensure PCB 14 - OPEN.

_ c) Close PCB 15.

CNS LOSS OF NORMAL POWER PAGE NO.

AP/11A155001007 1 - Page 4 of 12 128 of 154 Revision 57 Black Start Procedure ACTION/EXPECTED RESPONSE RESPONSE NOT OBTAINED

  • Desired loading rate is 1-2 MW increments.
  • Total load per unit may be initially limited to approximately 11 MWs.
14.

IF "TRANSF 1A" energized, THEN perform the following:

a. Energize 1 TD as follows:

_ 1) Place "7KV BUS 1 TD MODE SEL" switch in "MAN A & TIE".

_ 2) Close "7KV 1TD FDR FRM 1T1A".

_ 3) Verify "7KV BUS nD TIE BKR" -

CLOSED.

b. Energize 1 TC as follows:

_ 1) Verify with TCC that additional load can be accepted prior to energizing 6.9 KV bus.

_ 2) Place "7KV BUS 1TC MODE SEL" switch in "MAN A & TIE".

_ 3) Close "7KV 1TC FDR FRM 1T1A".

_ 4) Verify "7KV BUS 1TC TIE BKR"-

CLOSED.

c. Verify 1AD-11 C/2 "TRANSFORMER 1A FORCED COOLING REDUCTION"-

DARK.

1) Do not energize 1 TC until additional load can be accepted.
c. Restore transformer cooling. REFER TO OP/1/Al6350/005 (Alternate AC Power Sources).

CNS LOSS OF NORMAL POWER PAGE NO.

AP/1/ A15500/007 1 - Page 4 of 12 128 of 154 Revision 57 Black Start Procedure ACTION/EXPECTED RESPONSE RESPONSE NOT OBTAINED

  • Desired loading rate is 1-2 MW increments.
  • Total load per unit may be initially limited to approximately 11 MWs.
14.

IF "TRANSF 1A" energized, THEN perform the following:

a. Energize 1TD as follows:
1) Place "7KV BUS 1TD MODE SEL" switch in "MAN A & TIE".

_ 2) Close "7KV nD FDR FRM 1T1A".

_ 3) Verify "7KV BUS nD TIE BKR"-

CLOSED.

b. Energize nc as follows:
1) Verify with TCC that additional load can be accepted prior to energizing 6.9 KV bus.

_ 2) Place "7KV BUS 1TC MODE SEL" switch in "MAN A & TIE".

_ 3) Close "7KV nc FDR FRM 1T1A".

_ 4) Verify "7KV BUS 1TC TIE BKR"-

CLOSED.

c. Verify 1AD-11 C/2 "TRANSFORMER 1A FORCED COOLING REDUCTION"-

DARK.

1) Do not energize 1 TC until additional load can be accepted.
c. Restore transformer cooling. REFER TO OP/1/A16350/005 (Alternate AC Power Sources).

CNS LOSS OF NORMAL POWER PAGE NO.

AP/1 I Al55001007 1 - Page 5 of 12 129 of 154 Revision 57 Black Start Procedure ACTION/EXPECTED RESPONSE

14. (Continued)
d. Energize 1TB as follows:
1) Verify with TCC that additional load can be accepted prior to energizing 6.9 KV bus.

_ 2) Place "7KV BUS 1TB MODE SEL" switch in "MAN A & TIE".

3) Close "7KV 1TB FDR FRM 1T2A".

_ 4) Verify "7KV BUS 1TB TIE BKR"-

CLOSED.

e. Energize 1 T A as follows:
1) Verify with TCC that additional load can be accepted prior to energizing 6.9 KV bus.

_ 2) Place "7KV BUS 1TA MODE SEL" switch in "MAN A & TIE".

3) Close "7KV 1TA FDR FRM 1T2A".

_ 4) Verify "7KV BUS 1TA TIE BKR"-

CLOSED.

f.

Verify all 6.9 KV busses - ENERGIZED.

RESPONSE NOT OBTAINED

1) Do not energize 1 TB until additional load can be accepted.
1) Do not energize 1TA until additional load can be accepted.
f.

Perform the following:

1) IF waiting on TCC approval to energize additional 6.9 KV busses, THEN RETURN TO Step 14 and energize busses as TCC allows.

_ 2) IF all available 6.9 KV busses are energized, THEN GO TO Step 16.

CNS LOSS OF NORMAL POWER PAGE NO.

AP/1/A155001007 1 - Page 5 of 12 129 of 154 Revision 57 Black Start Procedure ACTION/EXPECTED RESPONSE

14. (Continued)
d. Energize 1TB as follows:
1) Verify with TCC that additional load can be accepted prior to energizing 6.9 KV bus.

_ 2) Place "7KV BUS 1TB MODE SEL" switch in "MAN A & TIE".

_ 3) Close "7KV 1TB FOR FRM 1T2A".

_ 4) Verify "7KV BUS 1TB TIE BKR"-

CLOSED.

e. Energize 1 T A as follows:
1) Verify with TCC that additional load can be accepted prior to energizing 6.9 KV bus.

_ 2) Place "7KV BUS 1TA MODE SEL" switch in "MAN A & TIE".

_ 3) Close "7KV 1TA FOR FRM 1T2A".

_ 4) Verify "7KV BUS 1TA TIE BKR"-

CLOSED.

f.

Verify all 6.9 KV busses - ENERGIZED.

RESPONSE NOT OBTAINED

1) Do not energize 1 TB until additional load can be accepted.
1) Do not energize 1T A until additional load can be accepted.
f.

Perform the following:

1) IF waiting on TCC approval to energize additional 6.9 KV busses, THEN RETURN TO Step 14 and energize busses as TCC allows.

_ 2) IF all available 6.9 KV busses are energized, THEN GO TO Step 16.

CNS LOSS OF NORMAL POWER PAGE NO.

AP/1/A155001007 1 - Page 6 of 12 130 of 154 Revision 57 Black Start Procedure ACTION/EXPECTED RESPONSE

15.

IF "TRANSF 1 B" energized, THEN perform the following:

a. Energize 1TD as follows:
1) Place "7KV BUS 1 TO MODE SEL" switch in "MAN B & TIE".

_ 2) Close "7KV HD FOR FRM 1T1B".

_ 3) Verify "7KV BUS 1TD TIE BKR"-

CLOSED.

b. Energize 1TC as follows:
1) Verify with TCC that additional load can be accepted prior to energizing 6.9 KV bus.

_ 2) Place "7KV BUS 1 TC MODE SEL" switch in "MAN B & TIE".

_ 3) Close "7KV HC FOR FRM 1T2B".

_ 4) Verify "7KV BUS 1TC TIE BKR"-

CLOSED.

c. Verify 1AD-11 F/2 "TRANSFORMER 1B FORCED COOLING REDUCTION" -

DARK.

d. Energize 1TB as follows:
1) Verify with TCC that additional load can be accepted prior to energizing 6.9 KV bus.

_ 2) Place "7KV BUS 1 TB MODE SEL" switch in "MAN B & TIE".

_ 3) Close "7KV 1TB FOR FRM 1T1B".

_ 4) Verify "7KV BUS 1TB TIE BKR"-

CLOSED.

RESPONSE NOT OBTAINED

1) Do not energize 1 TC until additional load can be accepted.
c. Restore transformer cooling. REFER TO OP/1/A163501005 (Alternate AC Power Sources).
1) Do not energize 1 TB until additional load can be accepted.

CNS LOSS OF NORMAL POWER PAGE NO.

AP/1/A/5500/007 1 - Page 6 of 12 130 of 154 Revision 57 Black Start Procedure ACTION/EXPECTED RESPONSE

15.

IF "TRANSF 1 B" energized, THEN perform the following:

a. Energize HD as follows:
1) Place "7KV BUS 1TD MODE SEL" switch in "MAN B & TIE".

_ 2) Close "7KV HD FDR FRM 1T1B".

3) Verify "7KV BUS HD TIE BKR" -

CLOSED.

b. Energize 1 TC as follows:
1) Verify with TCC that additional load can be accepted prior to energizing 6.9 KV bus.

_ 2) Place "7KV BUS 1TC MODE SEL" switch in "MAN B & TIE".

3) Close "7KV HC FDR FRM H2B".

_ 4) Verify "7KV BUS HC TIE BKR"-

CLOSED.

c. Verify 1AD-11 F/2 "TRANSFORMER 1 B FORCED COOLING REDUCTION" -

DARK.

d. Energize HB as follows:
1) Verify with TCC that additional load can be accepted prior to energizing 6.9 KV bus.

_ 2) Place "7KV BUS HB MODE SEL" switch in "MAN B & TIE".

_ 3) Close "7KV 1TB FDR FRM H1 B".

_ 4) Verify "7KV BUS HB TIE BKR" -

CLOSED.

RESPONSE NOT OBTAINED

1) Do not energize 1 TC until additional load can be accepted.
c. Restore transformer cooling. REFER TO OP/1/A/6350/005 (Alternate AC Power Sources).
1) Do not energize 1 TB until additional load can be accepted.

CNS LOSS OF NORMAL POWER PAGE NO.

AP/1/Al5500/007 1 - Page 7 of 12 131 of 154 Revision 57 Black Start Procedure ACTION/EXPECTED RESPONSE

15. (Continued)
e. Energize 1 TA as follows:

_ 1) Verify with TCC that additional load can be accepted prior to energizing 6.9 KV bus.

_ 2) Place "7KV BUS 1TA MODE SEL" switch in "MAN B & TIE".

_ 3) Close "7KV 1TA FDR FRM 1T2B".

_ 4) Verify "7KV BUS 1TA TIE BKR"-

CLOSED.

f.

Verify all 6.9 KV busses - ENERGIZED.

16.

Re-energize the shared 600 volt load centers that were isolated by Enclosure 25 (600 Volt Load Center Black Start Alignment) as follows:

a. Verify with TCC that additional load can be accepted prior to energizing 600 volt load centers.
b. Energize 1 SLXD as follows:

_ 1) Verify 1TD - ENERGIZED.

_ 2) Close 1 SLXD-4B (Load Center 1SLXD Incoming Breaker)..

RESPONSE NOT OBTAINED

_ 1) Do not energize 1TA until additional load can be accepted.

f.

Perform the following:

_ 1) IF waiting on TCC approval to energize additional 6.9 KV busses, THEN RETURN TO Step 15 and energize busses as TCC allows.

_ 2) IF all available 6.9 KV busses are energized, THEN GO TO Step 16.

a. Perform the following:

_ 1) WHEN additional load can be accepted, THEN perform Step 16.

_ 2) GO TO Step 17.

1) GO TO Step 16.c.

CNS LOSS OF NORMAL POWER PAGE NO.

AP/1/A/5500/007 1 - Page 7 of 12 131 of 154 Revision 57 Black Start Procedure ACTION/EXPECTED RESPONSE

15. (Continued)
e. Energize 1TA as follows:
1) Verify with TCC that additional load can be accepted prior to energizing 6.9 KV bus.
2) Place "7KV BUS 1TA MODE SEL" switch in "MAN B & TIE".
3) Close "7KV 1TA FDR FRM 1T2B".

_ 4) Verify "7KV BUS 1TA TIE BKR"-

CLOSED.

f.

Verify all 6.9 KV busses - ENERGIZED.

16.

Re-energize the shared 600 volt load centers that were isolated by Enclosure 25 (600 Volt Load Center Black Start Alignment) as follows:

a. Verify with TCC that additional load can be accepted prior to energizing 600 volt load centers.
b. Energize 1 SLXD as follows:
1) Verify 1TD - ENERGIZED.
2) Close 1 SLXD-4B (Load Center 1SLXD Incoming Breaker)..

RESPONSE NOT OBTAINED

1) Do not energize 1T A until additional load can be accepted.
f.

Perform the following:

1) IF waiting on TCC approval to energize additional 6.9 KV busses, THEN RETURN TO Step 15 and energize busses as TCC allows.
2) IF all available 6.9 KV busses are energized, THEN GO TO Step 16.
a. Perform the following:
1) WHEN additional load can be accepted, THEN perform Step 16.
2) GO TO Step 17.
1) GO TO Step 16.c.

CNS LOSS OF NORMAL POWER PAGE NO.

AP/1/AJ5500/007 1 - Page 8 of 12 132 of 154 Revision 57 Black Start Procedure ACTION/EXPECTED RESPONSE

16. (Continued)
c. Energize 1 SLXC as follows:
1) Verify 1TC - ENERGIZED.

_ 2) Verify with TCC that additional load can be accepted prior to energizing 600 volt load center.

_ 3) Close 1 SLXC-4B (Load Center 1 SLXC Normal Incoming Breaker).

d. Energize 1 SLXB as follows:
1) Verify 1TB - ENERGIZED.

_ 2) Verify with TCC that additional load can be accepted prior to energizing 600 volt load center.

_ 3) Close 1 SLXB-4B (Load Center 1SLXB Incoming Breaker).

e. Energize 1 SLXG as follows:
1) Verify 1TA-ENERGIZED.

_ 2) Verify with TCC that additional load can be accepted prior to energizing 600 volt load center.

_ 3) Close 1 SLXG-4B (Load Center 1 SLXG Incoming Breaker).

RESPONSE NOT OBTAINED

1) GO TO Step 16.d.
2) Perform the following:

_ a) WHEN additional load can be accepted, THEN perform Step 16.

_ b) GO TO Step 17.

1) GO TO Step 16.e.
2) Perform the following:

_ a) WHEN additional load can be accepted, THEN perform Step 16.

_ b) GO TO Step 17.

1) GO TO Step 16.f.
2) Perform the following:

_ a) WHEN additional load can be accepted, THEN perform Step 16.

_ b) GO TO Step 17.

CNS LOSS OF NORMAL POWER PAGE NO.

AP/1/ N5500/007 1 - Page 8 of 12 132 of 154 Revision 57 Black Start Procedure ACTION/EXPECTED RESPONSE

16. (Continued)
c. Energize 1 SLXC as follows:

_ 1) Verify 1TC - ENERGIZED.

_ 2) Verify with TCC that additional load can be accepted prior to energizing 600 volt load center.

_ 3) Close 1SLXC-4B (Load Center 1 SLXC Normal Incoming Breaker).

d. Energize 1 SLXB as follows:
1) Verify 1TB - ENERGIZED.

_ 2) Verify with TCC that additional load can be accepted prior to energizing 600 volt load center.

_ 3) Close 1SLXB-4B (Load Center 1SLXB Incoming Breaker).

e. Energize 1 SLXG as follows:

_ 1) Verify 1TA-ENERGIZED.

_ 2) Verify with TCC that additional load can be accepted prior to energizing 600 volt load center.

_ 3) Close 1 SLXG-4B (Load Center 1SLXG Incoming Breaker).

RESPONSE NOT OBTAINED

_ 1) GO TO Step 16.d.

2) Perform the following:

_ a) WHEN additional load can be accepted, THEN perform Step 16.

_ b) GO TO Step 17.

_ 1) GO TO Step 16.e.

2) Perform the following:

_ a) WHEN additional load can be accepted, THEN perform Step 16.

_ b) GO TO Step 17.

_ 1) GO TO Step 16.f.

2) Perform the following:

_ a) WHEN additional load can be accepted, THEN perform Step 16.

_ b) GO TO Step 17.

CNS LOSS OF NORMAL POWER PAGE NO.

AP 111 AJ55001007 1 - Page 9 of 12 133 of 154 Revision 57 Black Start Procedure ACTION/EXPECTED RESPONSE

16. (Continued)
f.

Energize 1 SLXA as follows:

1} Verify 1TA - ENERGIZED.

_ 2} Verify with TCC that additional load can be accepted prior to energizing 600 volt load center.

_ 3} Close 1 SLXA-4B (Load Center 1SLXA Incoming Breaker).

17.

Ensure the following battery chargers energized as follows:

  • WHEN 1TB is energized, THEN ensure Switchyard battery chargers energized.

REFER TO OP/O/B/63501015 (230 KV Switchyard 125 VDC Power System).

  • WHEN 1TC is energized, THEN ensure the following:
  • Aux Control Power battery chargers energized. REFER TO OP/1/B/63501009 (125 VDC 2401120 VAC Auxiliary Control Power System)
  • 250 VDC battery chargers energized.

REFER TO OP/O/B/63501007 (250 VDC Auxiliary Power System).

18.

Contact Chemistry to ensure YM is available for makeup to the UST.

RESPONSE NOT OBTAINED

_ 1} GO TO Step 17.

2} Perform the following:

_ a} WHEN additional load can be accepted, THEN perform Step 16.

_ b} GO TO Step 17.

CNS LOSS OF NORMAL POWER PAGE NO.

AP/11 Al55001007 1 - Page 9 of 12 133 of 154 Revision 57 Black Start Procedure ACTION/EXPECTED RESPONSE

16. (Continued)
f.

Energize 1 SLXA as follows:

_ 1) Verify 1TA - ENERGIZED.

_ 2) Verify with TCC that additional load can be accepted prior to energizing 600 volt load center.

_ 3) Close 1 SLXA-4B (Load Center 1SLXA Incoming Breaker).

17.

Ensure the following battery chargers energized as follows:

  • WHEN 1TB is energized, THEN ensure Switchyard battery chargers energized.

REFER TO OP/O/B/63501015 (230 KV Switchyard 125 VDC Power System).

  • WHEN 1TC is energized, THEN ensure the following:
  • Aux Control Power battery chargers energized. REFER TO OP/1/B/63501009 (125 VDC 240/120 VAC Auxiliary Control Power System)
  • 250 VDC battery chargers energized.

REFER TO OP/O/B/63501007 (250 VDC Auxiliary Power System).

18.

Contact Chemistry to ensure YM is available for makeup to the UST.

RESPONSE NOT OBTAINED

_ 1) GO TO Step 17.

2) Perform the following:

_ a) WHEN additional load can be accepted, THEN perform Step 16.

_ b) GO TO Step 17.

CNS LOSS OF NORMAL POWER PAGE NO.

AP/11 Al55001007 1 - Page 10 of 12 134 of 154 Revision 57 Black Start Procedure ACTION/EXPECTED RESPONSE

19.

IF AT ANY TIME the Tee requests additional load to stabilize the grid, THEN the following can be performed to provide rapid load to the grid:

a. Energize 1HTA as follows:
1) Verify 2HTA - DE-ENERGIZED.
2) Place 1 HT Al2HTA MODE SELECT switch (2MC-11) in - MANUAL.
3) Close 1 HTA-1 (Inc Fdr From Xfmr 1ATE).
4) Close 1 HTA-3 (600V Xfmr 1 &2 TXJ Fdr).
5) Ensure relay targets on front of 1 HTA Switchgear - RESET.
b. Start 1A cooling tower fans as needed to stabilize the grid. REFER TO OP/1/B/64001001A (Condenser Circulating Water System).
c. Start 2A cooling tower fans as needed to stabilize the grid. REFER TO OP/2/B/64001001A (Condenser Circulating Water System).

RESPONSE NOT OBTAINED 1 ) IF 1 HTA to be energized from Unit 2, THEN perform the following:

_ a) REFER TO OP/11A163501005 (Alternate AC Power Sources).

b) WHEN power available to cooling tower fans, THEN start fans as needed to stabilize the grid.

_ c) GO TO Step 20.

CNS LOSS OF NORMAL POWER PAGE NO.

AP/1/AJ55001007 1 - Page 10 of 12 134 of 154 Revision 57 Black Start Procedure ACTION/EXPECTED RESPONSE

19.

IF AT ANY TIME the TCC requests additional load to stabilize the grid, THEN the following can be performed to provide rapid load to the grid:

a. Energize 1HTA as follows:

_ 1) Verify 2HTA - DE-ENERGIZED.

_ 2) Place 1HTAJ2HTA MODE SELECT switch (2MC-11) in - MANUAL.

_ 3) Close 1 HTA-1 (Inc Fdr From Xfmr 1ATE).

_ 4) Close 1 HT A-3 (600V Xfmr 1 &2 TXJ Fdr).

_ 5) Ensure relay targets on front of 1 HT A Switchgear - RESET.

b. Start 1A cooling tower fans as needed to stabilize the grid. REFER TO OP/1/S/64001001A (Condenser Circulating Water System).
c. Start 2A cooling tower fans as needed to stabilize the grid. REFER TO OP/2/S/64001001A (Condenser Circulating Water System).

RESPONSE NOT OBTAINED

1) IF 1 HTA to be energized from Unit 2, THEN perform the following:

_ a) REFER TO OP/1/AJ63501005 (Alternate AC Power Sources).

_ b) WHEN power available to cooling tower fans, THEN start fans as needed to stabilize the grid.

_ c) GO TO Step 20.

CNS LOSS OF NORMAL POWER AP/1/A15500/007 1 - Page 11 of 12 Black Start Procedure ACTION/EXPECTED RESPONSE

19. (Continued)
d. IF desiree to align 1TXL and 2TXL from Unit 1, THEN perform the following:
1) Close 1 HTA-4 (600 V Xfmr 1 &2 TXL Fdr).

_ 2) Verify 2HTA-1 (600 V Xfmr 1&2 TXL Fdr) - OPEN.

e. Start 1 C cooling tower fans as needed to stabilize the grid. REFER TO OP/1/B/6400/001A (Condenser Circulating Water System).
f.

Start 2C cooling tower fans as needed to stabilize the grid. REFER TO OP/2/B/6400/001A (Condenser Circulating Water System).

_ g. IF desired to align 2HTA to Unit 1, THEN REFER TO OP/2/A16350/005 (Alternate AC Power Sources).

h. Place 1HTAl2HTA MODE SELECT switch (2MC-11) in - AUTO.

RESPONSE NOT OBTAINED PAGE NO.

135 of 154 Revision 57

20.

Verify with TCC that additional equipment can be energized.

Do not continue until additional load can be accepted.

21.

Restore Turbine Building Ventilation.

REFER TO OP/1/B/6450/016 (Turbine Building Ventilation Systems).

CNS LOSS OF NORMAL POWER AP/1/A155001007 1 - Page 11 of 12 Black Start Procedure ACTION/EXPECTED RESPONSE

19. (Continued)
d. IF desires to align nXL and 2TXL from Unit 1, THEN perform the following:
1) Close 1 HT A-4 (600 V Xfmr 1 &2 TXL Fdr).

_ 2) Verify 2HTA-1 (600 V Xfmr 1&2 TXL Fdr) - OPEN.

e. Start 1 C cooling tower fans as needed to stabilize the grid. REFER TO OP/1/B/64001001A (Condenser Circulating Water System).
f.

Start 2C cooling tower fans as needed to stabilize the grid. REFER TO OP/2IB/64001001A (Condenser Circulating Water System).

_ g. IF desired to align 2HT A to Unit 1, THEN REFER TO OP/21A163501005 (Alternate AC Power Sources).

h. Place 1HTAl2HTA MODE SELECT switch (2MC-11) in - AUTO.

RESPONSE NOT OBTAINED PAGE NO.

135 of 154 Revision 57

20.

Verify with TCC that additional equipment can be energized.

Do not continue until additional load can be accepted.

21.

Restore Turbine Building Ventilation.

REFER TO OP/1/B/6450/016 (Turbine Building Ventilation Systems).

CNS LOSS OF NORMAL POWER APf1f Al5500fOO7 1 - Page 12 of 12 Black Start Procedure ACTION/EXPECTED RESPONSE

22.

Coordinate with Unit 2 to restore the following systems to normal operation:

a. RL system. REFER TO OPfOfBf6400f003 (Low Pressure Service Water System).
b. KR system. REFER TO OPfOfBf6400f004 (Recirculated Cooling Water System)
c. VI system. REFER TO OPfOfAl6450f005 {Instrument Air System}.
d. WHEN the RL, KR and VI systems are operating as desired, THEN GO TO Step 23.
e. Do not continue.

RESPONSE NOT OBTAINED PAGE NO.

136 of 154 Revision 57

23.

Verify with TCC that additional equipment can be energized.

Do not continue until additional load can be accepted.

24.

Coordinate with Unit 2 to restore the following systems to normal:

  • Restore proper NF System operation.

REFER TO OPfOfAl6200f008 (Ice Condenser Refrigeration System).

  • Restore cooling to OAC computer room.

REFER TO OPfOfBf6450f014 (Computer Room Ventilation System).

25.

RETURN TO step in effect.

CNS LOSS OF NORMAL POWER AP/1/A/55001007 1 - Page 12 of 12 Black Start Procedure ACTION/EXPECTED RESPONSE

22.

Coordinate with Unit 2 to restore the following systems to normal operation:

a. RL system. REFER TO OP/O/S/64001003 (Low Pressure Service Water System).
b. KR system. REFER TO OP/O/S/64001004 (Recirculated Cooling Water System)
c. VI system. REFER TO OP/O/A/64501005 {Instrument Air System}.
d. WHEN the RL, KR and VI systems are operating as desired, THEN GO TO Step 23.
e. Do not continue.

RESPONSE NOT OBTAINED PAGE NO.

136 of 154 Revision 57

23.

Verify with TCC that additional equipment can be energized.

Do not continue until additional load can be accepted.

24.

Coordinate with Unit 2 to restore the following systems to normal:

  • Restore proper NF System operation.

REFER TO OP/O/A/62001008 (Ice Condenser Refrigeration System).

  • Restore cooling to OAC computer room.

REFER TO OP/O/S/64501014 (Computer Room Ventilation System).

25.

RETURN TO step in effect.

CATAWBA NUCLEAR STATION INITIAL LICENSE EXAMINATION JOB PERFORMANCE MEASURE JPM09 D Verify Adequate Shutdown Margin Following a Reactor Trip CANDIDATE EXAMINER JPM09 D Page 1 of 8 CATAWBA NUCLEAR STATION INITIAL LICENSE EXAMINATION JOB PERFORMANCE MEASURE JPM09 D Verify Adequate Shutdown Margin Following a Reactor Trip CANDIDATE EXAMINER JPM09D Page 1 of 8

CATAWBA NUCLEAR STATION INITIAL LICENSE EXAMINATION JOB PERFORMANCE MEASURE Verify Adequate Shutdown Margin Following a Reactor Trip Alternate Path:

YES Facility JPM #:

NEW KIA Rating(s):

EPE007 EA 1.09 (3.2/3.3) Ability to operate and/or monitor the following as they apply to a reactor trip - eves.

Task Standard:

Initiates boration based on lowest Tcold @ 30 gallons for each degree less than limit of Rod Book section 2.6. (for EOl snap 450EFPD this is 529°F)

Preferred Evaluation Simulator:

Preferred Evaluation Perform Simulator X

In-Plant __

Perform X

Simulate __

References:

EP/1/A/5000/ES-0.1 (Reactor Trip Response) Revision 030DeS Validation Time: 5 min.

Time Critical: No

=======================================================================

Candidate:

Time Start:

NAME Time Finish:

Performance Rating: SAT UNSAT Performance Time Examiner:

1 NAME SIGNATURE DATE

=======================================================================

COMMENTS JPM09 D Page 2 of 8 CATAWBA NUCLEAR STATION INITIAL LICENSE EXAMINATION JOB PERFORMANCE MEASURE Verify Adequate Shutdown Margin Following a Reactor Trip Alternate Path:

YES Facility JPM #:

NEW KJA Rating(s):

EPE007 EA 1.09 (3.2/3.3) Ability to operate and/or monitor the following as they apply to a reactor trip - CVCS.

Task Standard:

Initiates boration based on lowest T cold @ 30 gallons for each degree less than limit of Rod Book section 2.6. (for EOL snap 450EFPD this is 529°F)

Preferred Evaluation Simulator:

Preferred Evaluation Perform Simulator X

In-Plant __ _

Perform _...:...Xo--

Simulate __ _

References:

EP/1/A/5000/ES-0.1 (Reactor Trip Response) Revision 030DCS Validation Time: 5 min.

Time Critical: No

=======================================================================

Candidate:

Time Start:

NAME Time Finish:

Performance Rating:

SAT UNSAT Performance Time Examiner:

1 NAME SIGNATURE DATE

=======================================================================

COMMENTS JPM09D Page 2 of 8

SIMULATOR SETUP SHEET

1. Reset to any 100% IC set.
2. Insert EVENT 1 - x10i1160
3. Insert EVENT 2 - x10i218b
4. Insert MAL-SM002B (S/G PORV SV13 FAILURE), VALUE=58)
5. Insert VLV-NV044F (NV238A BORIC ACID BLEND FLOW CNTRL FAIL TO POSITION),

VALUE=0.8, EVENT 1

6. Insert VLV-NV044F (NV238A BORIC ACID BLEND FLOW CNTRL FAIL TO POSITION),

VALUE=0.8, EVENT 2

7. Insert OVR-SG047A (1SVML013 S/G 1B PORV - MAN CTRL LIGHTS GREEN LT), VALUE=ON
9. Insert OVR-SG047B (1SVML013 S/G 1 B PORV - MAN CTRL LIGHTS RED LT), VALUE=OFF
10. Manually trip the reactor.
11. Cooldown using PORVs to -520°F on Tcolds while maintaining Pzr level >17%.
12. When stable, close PORVs.
13. Freeze simulator and write to a SNAP.

IC SELECTED _____ _

SIMULATOR OPERATOR INSTRUCTIONS:

DO NOT go to RUN until candidate is ready to perform task.

Tools/Equipment/Procedures Needed:

EP/1/A15000/ES-O.1 (Reactor Trip Response) Revision 030DeS JPM09 D Page 3 of 8 SIMULATOR SETUP SHEET

1. Reset to any 100% IC set.
2. Insert EVENT 1 - x10i1160
3. Insert EVENT 2 - x10i218b
4. Insert MAL-SM002B (S/G PORV SV13 FAILURE), VALUE=58)
5. Insert VLV-NV044F (NV238A BORIC ACID BLEND FLOW CNTRL FAIL TO POSITION),

VALUE=0.8, EVENT 1

6. Insert VLV-NV044F (NV238A BORIC ACID BLEND FLOW CNTRL FAIL TO POSITION),

VALUE=0.8, EVENT 2

7. Insert OVR-SG047A (1SVML013 S/G 1B PORV - MAN CTRL LIGHTS GREEN LT), VALUE=ON
9. Insert OVR-SG047B (1SVML013 S/G 1B PORV - MAN CTRL LIGHTS RED LT), VALUE=OFF
10. Manually trip the reactor.
11. Cooldown using PORVs to -520°F on Tcolds while maintaining Pzr level >17%.
12. When stable, close PORVs.
13. Freeze simulator and write to a SNAP.

IC SELECTED _____

SIMULATOR OPERATOR INSTRUCTIONS:

DO NOT go to RUN until candidate is ready to perform task.

Tools/Equipment/Procedures Needed:

EP/1/A15000/ES-O.1 (Reactor Trip Response) Revision 030DCS JPM09 D Page 3 of 8

READ TO OPERATOR DIRECTION TO TRAINEE:

I will explain the initial conditions, and state the task to be performed. All control room steps shall be performed for this JPM, including any required communications. I will provide initiating cues and reports on other actions when directed by you. Ensure you indicate to me when you understand your assigned task. To indicate that you have completed your assigned task return the handout sheet I provided you.

INITIAL CONDITIONS:

A reactor trip occurred due to an EHC leak causing a turbine trip at 100% power. Actions are being performed in EP/11A1S000/ES-0.1 (Reactor Trip Response).

INITIATING CUES:

Perform a verification of shutdown margin per Step 7 of EP/11A1S000/ES-0.1.

JPM09 D Page 4 of 8 READ TO OPERATOR DIRECTION TO TRAINEE:

I will explain the initial conditions, and state the task to be performed. All control room steps shall be performed for this JPM, including any required communications. I will provide initiating cues and reports on other actions when directed by you. Ensure you indicate to me when you understand your assigned task. To indicate that you have completed your assigned task return the handout sheet I provided you.

INITIAL CONDITIONS:

A reactor trip occurred due to an EHC leak causing a turbine trip at 100% power. Actions are being performed in EP/11A15000/ES-0.1 (Reactor Trip Response).

INITIATING CUES:

Perform a verification of shutdown margin per Step 7 of EP/11A15000/ES-0.1.

JPM09 D Page 4 of 8

START TIME: __

STEP 7.a SAT Verify adequate shutdown margin as follows:

a. DRPI indication - AVAILABLE.

STANDARD: Notes DRPI indication is available.

UNSAT COMMENTS:

STEP 7.b:

b. All control and shutdown rods - FULL Y INSERTED.

SAT STANDARD:

Checks DRPI panel and notes all rods inserted.

UNSAT COMMENTS:

STEP 7.c:

CRITICAL STEP

c. All NC T-Colds - GREATER THAN 545°F.

STANDARD:

Notes temperatures are -522°F on Tcolds.

SAT COMMENTS:

UNSAT JPM09 D Page 5 of 8 START TIME: __

STEP 7.a SAT Verify adequate shutdown margin as follows:

a. DRPI indication - AVAILABLE.

STANDARD: Notes DRPI indication is available.

UNSAT COMMENTS:

STEP 7.b:

b. All control and shutdown rods - FULLY INSERTED.

SAT STANDARD:

Checks DRPI panel and notes all rods inserted.

UNSAT COMMENTS:

STEP 7.c:

CRITICAL STEP

c. All NC T-Colds - GREATER THAN 545°F.

STANDARD:

Notes temperatures are -522°F on Tcolds.

SAT COMMENTS:

UNSAT JPM09 D Page 5 of 8

STEP 7.c.1) RNO:

Perform the following:

Determine lowest T-Cold.

STANDARD:

Notes lowest Tcold is -522°F.

EXAMINER NOTE: The amount of boron to be added is based on the temperature noted by the candidate and may vary based on timing.

Record the temperature stated and subtracts it from 529°F. Multiply the result by 30 to get the total number of gallons to be added as a minimum.

(529 - ____ ) x 30 = ______ gallons COMMENTS STEP 7.c.2) RNO Determine core burnup in effective full power days (EFPD) (OAC Point P1457 or from Reactor Operators logbook).

STANDARD:

Based on OAC, core burn up is 450 EFPD.

COMMENTS STEP 7.c.3) RNO Verify lowest current T-Cold is greater than or equal to the allowable limit at present burnup. REFER TO ROD Book, Section 2.6.

STANDARD: Determines lower limit is 529°F from ROD BOOK section 2.6.

COMMENTS JPM09D CRITICAL STEP SAT UNSAT CRITICAL STEP SAT UNSAT CRITICAL STEP SAT UNSAT Page 6 of 8 STEP 7.c.1) RNO:

Perform the following:

Determine lowest T-Cold.

STANDARD:

Notes lowest Tcold is -522°F.

EXAMINER NOTE: The amount of boron to be added is based on the temperature noted by the candidate and may vary based on timing.

Record the temperature stated and subtracts it from 529°F. Multiply the result by 30 to get the total number of gallons to be added as a minimum.

(529 - ____ ) x 30 = ______ gallons COMMENTS STEP 7.c.2) RNO Determine core burnup in effective full power days (EFPD) (OAC Point P1457 or from Reactor Operators logbook).

STANDARD:

Based on OAC, core burn up is 450 EFPD.

COMMENTS STEP 7.c.3) RNO Verify lowest current T-Cold is greater than or equal to the allowable limit at present burnup. REFER TO ROD Book, Section 2.6.

STANDARD: Determines lower limit is 529°F from ROD BOOK section 2.6.

COMMENTS JPM09D CRITICAL STEP SAT UNSAT CRITICAL STEP SAT UNSAT CRITICAL STEP SAT UNSAT Page 6 of 8

STEP 7.cA) RNO IF lowest T-cold is less than allowable limit, THEN immediately add 30 gallons of 7000 PPM boron solution at greater than or equal to 30 GPM for each degree lowest T-Cold is below limit of ROD Book, Section 2.6.

STANDARD: Establishes ~ 30 gpm flow from the BAT using the emergency borate valve and determines the total amount to be added using the formula stated above.

(529 - 522) x 30 = 210 gallons (may vary based on temperature noted in step 7.c.1)

EXAMINER NOTE:

The normal blender flowpath if used will fail to meet the required 30 gpm flow but the emergency borate valve will work. The student will likely try the normal blender flowpath first.

COMMENTS STEP 7.cA) RNO GO TO Step 7.e.

STANDARD: Goes to step 7.e COMMENTS STEP 7.e:

Stop any boron dilutions in progress.

STANDARD: Ensures no dilutions are in progress.

COMMENTS This JPM is complete.

TIME STOP: __

JPM09 D CRITICAL STEP SAT UNSAT SAT UNSAT SAT UNSAT Page 7 of 8 STEP 7.cA) RNO IF lowest T-cold is less than allowable limit, THEN immediately add 30 gallons of 7000 PPM boron solution at greater than or equal to 30 GPM for each degree lowest T-Cold is below limit of ROD Book, Section 2.6.

STANDARD: Establishes ~ 30 gpm flow from the BAT using the emergency borate valve and determines the total amount to be added using the formula stated above.

(529 - 522) x 30 = 210 gallons (may vary based on temperature noted in step 7.c.1)

EXAMINER NOTE:

The normal blender flowpath if used will fail to meet the required 30 gpm flow but the emergency borate valve will work. The student will likely try the normal blender flowpath first.

COMMENTS STEP 7.cA) RNO GO TO Step 7.e.

STANDARD: Goes to step 7.e COMMENTS STEP 7.e:

Stop any boron dilutions in progress.

STANDARD: Ensures no dilutions are in progress.

COMMENTS This JPM is complete.

TIME STOP: ----

JPM09 D CRITICAL STEP SAT UNSAT SAT UNSAT SAT UNSAT Page 7 of 8

CANDIDATE CUE SHEET (TO BE RETURNED TO EXAMINER UPON COMPLETION OF TASK)

INITIAL CONDITIONS:

A reactor trip occurred due to an EHC leak causing a turbine trip at 100% power. Actions are being performed in EP/11A15000/ES-0.1 (Reactor Trip Response).

INITIATING CUES:

Perform a verification of shutdown margin per Step 7 of EP/11A15000/ES-0.1.

CANDIDATE CUE SHEET (TO BE RETURNED TO EXAMINER UPON COMPLETION OF TASK)

INITIAL CONDITIONS:

A reactor trip occurred due to an EHC leak causing a turbine trip at 100% power. Actions are being performed in EP/1/A/5000/ES-0.1 (Reactor Trip Response).

INITIATING CUES:

Perform a verification of shutdown margin per Step 7 of EP/1/A/5000/ES-0.1.

CNS REACTOR TRIP RESPONSE PAGE NO.

EP/1 IN5000/ES-0. 1 ACTION/EXPECTED RESPONSE

7.

Verify adequate shutdown margin as follows:

a. DRPI indication - AVAILABLE.

50f30 Rev 30DCS RESPONSE NOT OBTAINED

a. Verify adequate shutdown margin as follows:
1) Emergency borate 14,000 gallons of 7000 PPM boron solution as follows:

_ a) Open 1 NV-236B (Boric Acid To NV Pumps Suct).

_ b) IF 1 NV-236B will not open, THEN dispatch operator to open 1 NV-236B (Boric Acid To NV Pumps Suet) (AB-550, HH-JJ, 53-54, Rm 234).

c) WHEN 1 NV-236B is open, THEN:

_ (1) Start boric acid transfer pumps.

_ (2) Calculate required injection time based on boric acid flowrate.

_ (3) WHEN required boric acid is injected, THEN secure emergency boration.

_ 2) Notify Reactor Group Duty Engineer to perform analysis to determine required shutdown margin.

_ 3) GO TO Step 7.c.

CNS REACTOR TRIP RESPONSE PAGE NO.

EP/1/N5000/ES-0.1 ACTION/EXPECTED RESPONSE

7.

Verify adequate shutdown margin as follows:

a. DRPI indication - AVAILABLE.

5 of 30 Rev 30DCS RESPONSE NOT OBTAINED

a. Verify adequate shutdown margin as follows:
1) Emergency borate 14,000 gallons of 7000 PPM boron solution as follows:

_ a) Open 1 NV-236B (Boric Acid To NV Pumps Suct).

_ b) IF 1 NV-236B will not open, THEN dispatch operator to open 1 NV-236B (Boric Acid To NV Pumps Suct) (AB-550, HH-JJ, 53-54, Rm 234).

c) WHEN 1 NV-236B is open, THEN:

_ (1) Start boric acid transfer pumps.

_ (2) Calculate required injection time based on boric acid flowrate.

_ (3) WHEN required boric acid is injected, THEN secure emergency boration.

_ 2) Notify Reactor Group Duty Engineer to perform analysis to determine required shutdown margin.

_ 3) GO TO Step 7.c.

CNS REACTOR TRIP RESPONSE PAGE NO.

EP/1/A/5000/ES-0.1 ACTION/EXPECTED RESPONSE

7. (Continued)
b. All control and shutdown rods - FULLY INSERTED.

60f30 Rev30DCS RESPONSE NOT OBTAINED

b. IF two or more rods are not fully inserted, THEN:
1) Emergency borate 150 PPM for each rod not fully inserted as follows:

_ a) Open 1 NV-236B (Boric Acid To NV Pumps Suct).

_ b) IF 1 NV-236B will not open, THEN dispatch operator to open 1 NV-236B (Boric Acid To NV Pumps Suct) (AB-550, HH-JJ, 53-54, Rm 234).

c) WHEN 1 NV-236B is open, THEN:

_ (1) Start boric acid transfer pumps.

_ (2) Calculate required boron addition. REFER TO ROD Book, Section 4.1.

_ (3) Calculate required injection time based on boric acid flowrate.

_ (4) WHEN required boric acid is injected, THEN secure emergency boration.

_ 2) Notify Reactor Group Duty Engineer to perform analysis to determine required shutdown margin.

CNS REACTOR TRIP RESPONSE PAGE NO.

EP/1/A/5000/ES-0.1 ACTION/EXPECTED RESPONSE

7. (Continued)
b. All control and shutdown rods - FULLY INSERTED.

6 of 30 Rev 30DCS RESPONSE NOT OBTAINED

b. IF two or more rods are not fully inserted, THEN:
1) Emergency borate 150 PPM for each rod not fully inserted as follows:

_ a) Open 1 NV-236B (Boric Acid To NV Pumps Suct).

b) IF 1 NV-236B will not open, THEN dispatch operator to open 1 NV-236B (Boric Acid To NV Pumps Suct) (AB-550, HH-JJ, 53-54, Rm 234).

c) WHEN 1 NV-236B is open, THEN:

_ (1) Start boric acid transfer pumps.

_ (2)

Calculate required boron addition. REFER TO ROD Book, Section 4.1.

_ (3) Calculate required injection time based on boric acid flowrate.

_ (4) WHEN required boric acid is injected, THEN secure emergency boration.

_ 2) Notify Reactor Group Duty Engineer to perform analysis to determine required shutdown margin.

CNS REACTOR TRIP RESPONSE PAGE NO.

EP/1/A15000/ES-0.1 70f30 Rev30DCS ACTION/EXPECTED RESPONSE RESPONSE NOT OBTAINED

7. (Continued)
c. All NC T-Colds - GREATER THAN
c. Perform the following:

545°F.

_1) Determine lowest T-Cold.

_ 2) Determine core burnup in effective full power days (EFPD) (OAC Point P1457 or from Reactor Operators logbook).

3) Verify lowest current T -Cold is greater than or equal to the allowable limit at present burnup.

REFER TO ROD Book, Section 2.6.

_4) IF lowest T-Cold is less than allowable limit, THEN immediately add 30 gallons of 7000 PPM boron solution at greater than or equal to 30 GPM for each degree lowest T -Cold is below limit of ROD Book, Section 2.6.

5) GO TO Step 7.e.
d. IF AT ANY TIME NC T-Colds decrease to less than or equal to 545°F, THEN perform Step 7.c.
e. Stop any boron dilutions in progress.

CNS REACTOR TRIP RESPONSE PAGE NO.

EP/1/A/5000/ES-0.1 7 of 30 Rev30DCS ACTION/EXPECTED RESPONSE RESPONSE NOT OBTAINED

7. (Continued)
c. All NC T-Colds - GREATER THAN
c. Perform the following:

545°F.

1) Determine lowest T-Cold.
2) Determine core burnup in effective full power days (EFPD) (OAC Point P1457 or from Reactor Operators logbook).
3) Verify lowest current T -Cold is greater than or equal to the allowable limit at present burnup.

REFER TO ROD Book, Section 2.6.

_4) IF lowest T -Cold is less than allowable limit, THEN immediately add 30 gallons of 7000 PPM boron solution at greater than or equal to 30 GPM for each degree lowest T -Cold is below limit of ROD Book, Section 2.6.

5) GO TO Step 7.e.
d. IF AT ANY TIME NC T-Colds decrease to less than or equal to 545°F, THEN perform Step 7.c.
e. Stop any boron dilutions in progress.

CATAWBA NUCLEAR STATION INITIAL LICENSE EXAMINATION JOB PERFORMANCE MEASURE JPM09 E Place Steam Dumps in Automatic Mode in Preparation for Unit Startup CANDIDATE EXAMINER JPM09 E Page 1 of 10 CATAWBA NUCLEAR STATION INITIAL LICENSE EXAMINATION JOB PERFORMANCE MEASURE JPM09 E Place Steam Dumps in Automatic Mode in Preparation for Unit Startup CANDIDATE EXAMINER JPM09 E Page 1 of 10

CATAWBA NUCLEAR STATION INITIAL LICENSE EXAMINATION JOB PERFORMANCE MEASURE Place Steam Dumps in Automatic Mode in Preparation for Unit Startup Alternate Path:

No Facility JPM #:

N/A (new)

KIA Rating(s):

SYS041 A3.02 (3.3/3.4) - Ability to monitor automatic operation of the SDS, including RCS pressure, RCS temperature, and reactor power.

Task Standard:

Places Steam Dumps in automatic operation per OP/1/A161 001001 (Controlling Procedure for Unit Startup).

Preferred Evaluation Simulator:

Preferred Evaluation Perform Simulator X

In-Plant __ _

Perform _~X,,--

Simulate __ _

References:

OP/1/A161001001 (Controlling Procedure for Unit Startup), Enclosure 4.1 revision 217DCS OP/1/A162501006 (Main Steam), Enclosure 4.5 revision 041 Validation Time: 10 min.

Time Critical: No

=======================================================================

Candidate:

Time Start:

NAME Time Finish:

Performance Rating:

SAT UNSAT Performance Time Examiner:

1 NAME SIGNATURE DATE

=======================================================================

COMMENTS JPM09 E Page 2 of 10 CATAWBA NUCLEAR STATION INITIAL LICENSE EXAMINATION JOB PERFORMANCE MEASURE Place Steam Dumps in Automatic Mode in Preparation for Unit Startup Alternate Path:

No Facility JPM #:

N/A (new)

KIA Rating(s):

SYS041 A3.02 (3.3/3.4) - Ability to monitor automatic operation of the SDS, including RCS pressure, RCS temperature, and reactor power.

Task Standard:

Places Steam Dumps in automatic operation per OP/1/A/61 001001 (Controlling Procedure for Unit Startup).

Preferred Evaluation Simulator:

Preferred Evaluation Perform Simulator X

In-Plant __ _

Perform _...!.X.!.....-

Simulate __ _

References:

OP/1/A/61001001 (Controlling Procedure for Unit Startup), Enclosure 4.1 revision 217DCS OP/1/A/62501006 (Main Steam), Enclosure 4.5 revision 041 Validation Time: 10 min.

Time Critical: No

=======================================================================

Candidate:

Time Start:

NAME Time Finish:

Performance Rating: SAT UNSAT Performance Time Examiner:

1 NAME SIGNATURE DATE

=======================================================================

COMMENTS JPM09 E Page 2 of 10

SIMULATOR SETUP SHEET

1. Reset to a BOL 10-8 amp snap
2. Open MSIV bypass valves
3. Close MSIVs
4. Reduce Tavg to -554-555°F
5. Adjust steam dump demand to "0" and place in manual
6. When stable, freeze simulator and write to a SNAP.

IC SELECTED _____ _

SIMULATOR OPERATOR INSTRUCTIONS:

Do not place the simulator in RUN until the candidate is ready to begin.

Tools/Equipment/Procedures Needed:

OP/1/A/6100/001 (Controlling Procedure for Unit Startup), Enclosure 4.1 revision 217 OP/1/A/6250/006 (Main Steam), Enclosure 4.5 revision 041 JPM09 E Page 3 of 10 SIMULATOR SETUP SHEET

1. Reset to a BOL 10-8 amp snap
2. Open MSIV bypass valves
3. Close MSIVs
4. Reduce Tavg to -554-555°F
5. Adjust steam dump demand to "0" and place in manual
6. When stable, freeze simulator and write to a SNAP.

IC SELECTED _____ _

SIMULATOR OPERATOR INSTRUCTIONS:

Do not place the simulator in RUN until the candidate is ready to begin.

Tools/Equipment/Procedures Needed:

OP/1/Al6100/001 (Controlling Procedure for Unit Startup), Enclosure 4.1 revision 217 OP/1/Al6250/006 (Main Steam), Enclosure 4.5 revision 041 JPM09 E Page 3 of 10

READ TO OPERATOR DIRECTION TO TRAINEE:

I will explain the initial conditions, and state the task to be performed. All control room steps shall be performed for this JPM, including any required communications. I will provide initiating cues and reports on other actions when directed by you. Ensure you indicate to me when you understand your assigned task. To indicate that you have completed your assigned task return the handout sheet I provided you.

INITIAL CONDITIONS:

Unit 1 is preparing to increase power from 1 x 10-8 amps. Pressure equalization across the MSIVs is in progress through step 2.2 of OP/1/Al6250/006 (Main Steam), Enclosure 4.5.

INITIATING CUES:

Complete steps 2.137 - 2.139 of OP/1/Al61 00/001 (Controlling Procedure for Unit Startup), Enclosure 4.1 (Unit Startup) to place steam dumps in automatic operation in preparation for increasing power to 1%.

JPM09 E Page 4 of 10 READ TO OPERATOR DIRECTION TO TRAINEE:

I will explain the initial conditions, and state the task to be performed. All control room steps shall be performed for this JPM, including any required communications. I will provide initiating cues and reports on other actions when directed by you. Ensure you indicate to me when you understand your assigned task. To indicate that you have completed your assigned task return the handout sheet I provided you.

INITIAL CONDITIONS:

Unit 1 is preparing to increase power from 1 x 10-8 amps. Pressure equalization across the MSIVs is in progress through step 2.2 of OP/1/A/6250/006 (Main Steam), Enclosure 4.5.

INITIATING CUES:

Complete steps 2.137 - 2.139 of OP/1/A/61 00/001 (Controlling Procedure for Unit Startup), Enclosure 4.1 (Unit Startup) to place steam dumps in automatic operation in preparation for increasing power to 1 %.

JPM09 E Page 4 of 10

START TIME: __

STEP 2.137:

Establish automatic steam dump control as follows: (RM) 2.137.1 Adjust the "Stm Dump Ctrl" setpoint to 1092 psig.

STANDARD:

Sets "Stm Dump Ctrl" to 1 092 psig.

COMMENTS:

STEP 2.137.2:

Ensure MSIVs are open per Step 2.136.3.

STANDARD:

Notes that step 2.136.3 is not signed off, and per the initiating cue, equalization of pressure across the MSIVs is in progress.

EXAMINER NOTE: The student should review the equalization paperwork and determine that steps need to be completed in OP/1/A/6250/006.

COMMENTS:

Transition to OP/1/A/6250/006 (Main Steam)

STEP 2.3:

Verify the MSIV Bypass Valves have been open for greater than the minimum time specified in Step 2.1 STANDARD: Notes that at current plant conditions, >30 minutes is required and per step 2.2, the time opened is listed as "40 MIN AGO" so he/she can continue.

COMMENTS JPM09 E CRITICAL STEP SAT

_UNSAT SAT

_UNSAT SAT

_UNSAT Page 5 of 10 START TIME: __

STEP 2.137:

Establish automatic steam dump control as follows: (RM) 2.137.1 Adjust the "Stm Dump Ctrl" setpoint to 1092 psig.

STANDARD:

Sets "Stm Dump Ctrl" to 1092 psig.

COMMENTS:

STEP 2.137.2:

Ensure MSIVs are open per Step 2.136.3.

STANDARD:

Notes that step 2.136.3 is not signed off, and per the initiating cue, equalization of pressure across the MSIVs is in progress.

EXAMINER NOTE: The student should review the equalization paperwork and determine that steps need to be completed in OP/1/N6250/006.

COMMENTS:

Transition to OP/1/N6250/006 (Main Steam)

STEP 2.3:

Verify the MSIV Bypass Valves have been open for greater than the minimum time specified in Step 2.1 STANDARD: Notes that at current plant conditions, >30 minutes is required and per step 2.2, the time opened is listed as "40 MIN AGO" so he/she can continue.

COMMENTS JPM09 E CRITICAL STEP SAT UNSAT SAT UNSAT SAT UNSAT Page 5 of 10

NOTE:

Always use analog computer points when monitoring pressures.

The time required to equalize pressure across the S/G MSIVs will be directly dependent on the temperature of the downstream piping. It may require several hours to equalize when piping is cold.

STANDARD: Reads note and acknowledges it.

COMMENTS STEP 2.4 If steam pressure has equalized across the S/G SM Isolations AND Main Steam header pressure no longer trending towards S/G pressure AND differential pressure across the S/G SM Isolations < 10 psid, then perform the following:

2.4.1 Open the following valves one at a time:

1 SM-1 (S/G 1 D SM Isol) 1SM-3 (S/G 1C SM Isol) 1 SM-5 (S/G 1 B SM Isol) 1SM-7 (S/G 1A SM Isol)

STANDARD Depresses the OPEN pushbutton and verifies the RED OPEN light illuminates for each valve.

COMMENTS JPM09 E SAT UNSAT CRITICAL STEP SAT UNSAT Page 6 of 10 NOTE:

Always use analog computer points when monitoring pressures.

The time required to equalize pressure across the S/G MSIVs will be directly dependent on the temperature of the downstream piping. It may require several hours to equalize when piping is cold.

STANDARD: Reads note and acknowledges it.

COMMENTS STEP 2.4 If steam pressure has equalized across the S/G SM Isolations AND Main Steam header pressure no longer trending towards S/G pressure AND differential pressure across the S/G SM Isolations < 10 psid, then perform the following:

2.4.1 Open the following valves one at a time:

1 SM-1 (S/G 1 D SM Isol) 1 SM-3 (S/G 1 C SM Isol) 1 SM-5 (S/G 1 B SM Isol) 1SM-7 (S/G 1A SM Isol)

STANDARD Depresses the OPEN pushbutton and verifies the RED OPEN light illuminates for each valve.

COMMENTS JPM09 E SAT UNSAT CRITICAL STEP SAT UNSAT Page 6 of 10

STEP 2.4.2:

2.4.2 When the S/G SM Isolations are fully open, close the following valves:

1 SM-9 (S/G 1 D SM Isol 8yp) 1SM-10 (S/G 1C SM Isol 8yp) 1SM-11 (S/G 18 SM Isol 8yp)

STANDARD:

Turns the control knob for each valve counterclockwise and notes the valve position indicator going to 0, GREEN light comes on and RED light goes off.

COMMENTS STEP 2.4.3:

N/A the remaining steps of this enclosure.

STANDARD: N/As remaining steps.

COMMENTS Transition back to OP/1/A/61 00/001 (Controlling Procedure for Unit Startup)

STEP 2.136.3 Equalize pressure across and open the MSIVs per OP/1/A/6250/006 (Main Steam)

STANDARD: Step is signed off as complete.

COMMENTS JPM09 E CRITICAL STEP SAT UNSAT SAT UNSAT SAT UNSAT Page 7 of 10 STEP 2.4.2:

2.4.2 When the S/G SM Isolations are fully open, close the following valves:

1SM-9 (S/G 1D SM Isol Byp) 1SM-10 (S/G 1C SM Isol Byp) 1SM-11 (S/G 1B SM Isol Byp) 1SM-12 (S/G 1A SM Isol Byp)

STANDARD:

Turns the control knob for each valve counterclockwise and notes the valve position indicator going to 0, GREEN light comes on and RED light goes off.

COMMENTS STEP 2.4.3:

N/A the remaining steps of this enclosure.

STANDARD: N/As remaining steps.

COMMENTS Transition back to OP/1/A/61 00/001 (Controlling Procedure for Unit Startup)

STEP 2.136.3 Equalize pressure across and open the MSIVs per OP/1/A/6250/006 (Main Steam)

STANDARD: Step is signed off as complete.

COMMENTS JPM09 E CRITICAL STEP SAT UNSAT SAT UNSAT SAT UNSAT Page 7 of 10

STEP 2.137.2:

SAT Ensure MSIVs are open per Step 2.136.3 STANDARD: Notes MSIVs are open and checks off.

UNSAT COMMENTS STEP 2.135.3:

Ensure T-AVG is less than or equal to 55JDF per Step 2.134.1.

SAT STANDARD: Notes that step 2.134.1 is signed off and current Tavg is

<55JDF. Checks off this step.

COMMENTS UNSAT STEP 2.135.4:

CRITICAL STEP Place the "Stm Dump Ctrl" in auto.

STANDARD Depresses the "A" pushbutton on the steam dump controller.

SAT COMMENTS UNSAT JPM09 E Page 8 of 10 STEP 2.137.2:

SAT Ensure MSIVs are open per Step 2.136.3 STANDARD: Notes MSIVs are open and checks off.

UNSAT COMMENTS STEP 2.135.3:

Ensure T -AVG is less than or equal to 55rF per Step 2.134.1.

SAT STANDARD: Notes that step 2.134.1 is signed off and current Tavg is

<55rF. Checks off this step.

COMMENTS UNSAT STEP 2.135.4:

CRITICAL STEP Place the "Stm Dump Ctrl" in auto.

STANDARD Depresses the "A" pushbutton on the steam dump controller.

SAT COMMENTS UNSAT JPM09 E Page 8 of 10

STEP 2.136:

Turn the following switches to the "ON" position:

Steam Dump Intlk Byp Trn A Steam Dump Intlk Byp Trn B STANDARD Turns hand switches to the ON position.

COMMENTS STEP 2.137:

When the MSIVs are open verify the steam dumps maintain approximately 1090 psig.

STANDARD Notes that steam pressure is maintained at approximately 1092 psig.

EXAMINER NOTE: If temperature is < 557°F, dumps will remain closed.

COMMENTS This JPM is complete.

TIME STOP: __

JPM09 E CRITICAL STEP SAT UNSAT SAT

_UNSAT Page 9 of 10 STEP 2.136:

Turn the following switches to the "ON" position:

Steam Dump Intlk Byp Trn A Steam Dump Intlk Byp Trn B STANDARD Turns hand switches to the ON position.

COMMENTS STEP 2.137:

When the MSIVs are open verify the steam dumps maintain approximately 1090 psig.

STANDARD Notes that steam pressure is maintained at approximately 1092 psig.

EXAMINER NOTE: If temperature is < 557°F, dumps will remain closed.

COMMENTS This JPM is complete.

TIME STOP: __

JPM09 E CRITICAL STEP SAT UNSAT SAT UNSAT Page 9 of 10

CANDIDATE CUE SHEET (TO BE RETURNED TO EXAMINER UPON COMPLETION OF TASK)

INITIAL CONDITIONS:

Unit 1 is preparing to increase power from 1 x 10-8 amps. Pressure equalization across the MSIVs is in progress through step 2.2 of OP/1/Al6250/006 (Main Steam), Enclosure 4.5.

INITIATING CUES:

Complete steps 2.137 - 2.139 of OP/1/Al61 00/001 (Controlling Procedure for Unit Startup), Enclosure 4.1 (Unit Startup) to place steam dumps in automatic operation in preparation for increasing power to 1%.

CANDIDATE CUE SHEET (TO BE RETURNED TO EXAMINER UPON COMPLETION OF TASK)

INITIAL CONDITIONS:

Unit 1 is preparing to increase power from 1 x 10-8 amps. Pressure equalization across the MSIVs is in progress through step 2.2 of OP/1/A/62501006 (Main Steam), Enclosure 4.5.

INITIATING CUES:

Complete steps 2.137 - 2.139 of OP/1/A/61 001001 (Controlling Procedure for Unit Startup), Enclosure 4.1 (Unit Startup) to place steam dumps in automatic operation in preparation for increasing power to 1 %.

I I

I I

.5 OP!l/A/625 0/006 Equalizing Pressure Across the Main Steam Page 1 of 6 Isolation Valves

1. Initial Conditions 1.1 Review the Limits and Precautions.

1.2 Verify the following valves are closed:

0 lSM-1 (S/G 1D SM Isol) 0 lSM-3 (S/G 1C SM Isol) 0 lSM-5 (S/G 1B SM Isol) 0 lSM-7 (S/G 1A SM Isol) 0 lSM-9 (S/G 1D SM Isol Byp) 0 lSM-lO (S/G 1C SM Isol Byp) 0 ISM-II (S/G 1B SM Isol Byp) 0 lSM-12 (S/G 1A SM Isol Byp) 1.3 VerifyNC Temperature> 200°F.

2. Procedure CAUTION:
  • S/G level indication may shrink or swell when the MSIV's are opened due to the change in S/G pressure. This could result in an inadvertent S/G high or low level actuation. {PIP 99-2428}

P-14 may be blocked when the unit is in Modes 4-6 and in No Mode.

OP/1/ A/6100/002 (Controlling Procedure for Unit Shutdown) provides guidance on the blocking ofP-14.

2.1 Determine the minimum time required to equalize pressure across the MSIV's based on current NC System temperature. Refer to the table below: {PIP 99-2428}

NC Tcold eF)

TIME REQUIRED (MIN) 200 - 224 180 225 -249 120 250-299 90 300 - 350 60

> 350 30.5 OP/l!AJ6250/006 Equalizing Pressure Across the Main Steam Page 1 of 6 Isolation Valves

1. Initial Conditions 1.1 Review the Limits and Precautions.

1.2 Verify the following valves are closed:

0 lSM-1 (S/G 1D SM Isol) 0 lSM-3 (S/G 1C SM Isol) 0 lSM-5 (S/G 1B SM Isol) 0 lSM-7 (S/G 1A SM Isol) 0 lSM-9 (S/G 1D SM Isol Byp) 0 lSM-10 (S/G 1C SM Isol Byp) 0 lSM-ll (S/G 1B SM Isol Byp) 0 lSM-12 (S/G 1A SM Isol Byp) 1.3 VerifyNC Temperature> 200°F.

2. Procedure CAUTION:
  • S/G level indication may shrink or swell when the MSIV's are opened due to the change in S/G pressure. This could result in an inadvertent S/G high or low level actuation. {PIP 99-2428}

P-14 may be blocked when the unit is in Modes 4-6 and in No Mode.

OP/1/AJ6100/002 (Controlling Procedure for Unit Shutdown) provides guidance on the blocking of P-14.

2.1 Determine the minimum time required to equalize pressure across the MSIV's based on current NC System temperature. Refer to the table below: {PIP 99-2428}

NC Tcold eF)

TIME REQUIRED (MIN) 200 - 224 180 225 -249 120 250 -299 90 300 - 350 60

> 350 30

.5 op;1/A/625 0/006 Equalizing Pressure Across the Main Steam Page 2 of 6 Isolation Valves 2.2 Slowly open the following valves:

o ISM-9 (S/G ID SM Isol Byp) o ISM-lO (S/G Ie SM Isol Byp) o ISM-ll (S/G IB SM Isol Byp) o ISM-12 (S/G lA SM Isol Byp)

Time last valve was opened -----

-- 2.3 Verify the MSIV Bypass Valves have been open greater than the minimum time specified in Step 2.1.

NOTE:

Always use analog computer points when monitoring pressures.

The time required to equalize pressure across the MSIV s will be directly dependent on the temperature of the downstream piping. It may require several hours to equalize when piping is cold.

2.4 IF stearn pressure has equalized across the S/G SM Isolations AND Main Stearn header pressure no longer trending towards S/G pressure AND differential pressure across the S/G SM Isolations < 10 psid, then perform the following:

2.4.1 Open the following valves one at a time:

o ISM-l (S/G ID SM Isol) o ISM-3 (S/G Ie SM Isol) o ISM-5 (S/G IB SM Isol) o ISM-7 (S/G lA SM Isol) 2.4.2 WHEN the S/G SM Isolations are fully open, close the following valves:

o ISM-9 (S/G ID SM Isol Byp) o ISM-I0 (S/G Ie SM Isol Byp) o ISM-ll (S/G IB SM Isol Byp) o ISM-12 (S/G lA SM Isol Byp) 2.4.3 N/ A the remaining steps of this enclosure.

2.5 Maintain a minimum constant S/G blowdown rate on all four S/Gs as low as S/G water chemistry allows.

2.6 Ensure S/G levels approx. equal across all four S/Gs..5 OP/l/A/62so/006 Equalizing Pressure Across the Main Steam Page 2 of 6 Isolation Valves 2.2 Slowly open the following valves:

D lSM-9 (S/G lD SM Isol Byp)

D ISM-I0 (S/G Ie SM Isol Byp)

D ISM-ll (S/G IB SM Isol Byp)

D ISM-12 (S/G lA SM Isol Byp)

Time last valve was opened. ____ _

-- 2.3 Verify the MSIV Bypass Valves have been open greater than the minimum time specified in Step 2.1.

NOTE:

Always use analog computer points when monitoring pressures.

The time required to equalize pressure across the MSIV s will be directly dependent on the temperature of the downstream piping. It may require several hours to equalize when piping is cold.

2.4 IF steam pressure has equalized across the S/G SM Isolations AND Main Steam header pressure no longer trending towards S/G pressure AND differential pressure across the S/G SM Isolations < 10 psid, then perform the following:

2.4.1 Open the following valves one at a time:

D ISM-l (S/G ID SM Isol)

D ISM-3 (S/G Ie SM Isol)

D ISM-S (S/G IB SM Isol)

D ISM-7 (S/G lA SM Isol) 2.4.2 WHEN the S/G SM Isolations are fully open, close the following valves:

D ISM-9 (S/G ID SM Isol Byp)

D ISM-lO (S/G Ie SM Isol Byp)

D ISM-ll (S/G IB SM Isol Byp)

D ISM-12 (S/G lA SM Isol Byp) 2.4.3 N/ A the remaining steps of this enclosure.

2.S Maintain a minimum constant S/G blowdown rate on all four S/Gs as low as S/G water chemistry allows.

2.6 Ensure S/G levels approx. equal across all four S/Gs.

.1 Unit Startup OP/VA/6100/001 Page 43 of66 2.135 IF Step 2.6 was completed to supply Unit 1 Turbine warming from the AS System, perform the following to restore AS to normal alignment: (R.M.)

2.135.1 Ensure turbine warming has been secured.

2.135.2 Notify the Control Room Supervisor that an approximate 5 MW increase in generator output on Unit 2 may occur when isolating the Unit 2 supply via the AS System for Unit 1 Turbine Shell Warming.

2.135.3 Monitor the Unit 1 SM piping for water hammer.

2.135.4 Notify the Control Room Supervisor to monitor Unit 2 Reactor Power, Generator MW, and AS header pressure while performing the following step.

2.135.5 Slowly close lAS-4 (Main Steam to Aux Steam Header Control Bypass) (TB-61O, lM-32).

2.136 IF the NC System heatup was performed with the MSN's closed, open the MSN's as follows:

CAUTION: Main steamline drains shall be open for at least 15 minutes prior to opening MSNs or MSN Bypasses.

-- 2.136.1 Open the following valves:

D ISM-132 (SM Equalization Hdr Trap T-05 Byp) (TB-594, IH-32)

D ISM-139 (SM Equalization Hdr Trap T-06 Byp).(TB-594, IH-32)

-- 2.136.2 After 15 minutes, close the following valves:

D ISM-132 (SM Equalization Hdr Trap T-05 Byp)

D ISM':139 (SM Equalization Hdr Trap T-06 Byp).

NOTE:

The following step will take a minimum of 30 minutes to perform. The procedure may continue while performing Step 2.136.3 2.136.3 Equalize pressure across and open the MSN's per OP/l/A/6250/006 (Main Steam)..1 Unit Startup OP/l!A/61001001 Page 43 of 66 2.135 IF Step 2.6 was completed to supply Unit 1 Turbine warming from the AS System, perform the following to restore AS to normal alignment: (R.M.)

2.135.l Ensure turbine warming has been secured.

2.135.2 Notify the Control Room Supervisor that an approximate 5 MW increase in generator output on Unit 2 may occur when isolating the Unit 2 supply via the AS System for Unit 1 Turbine Shell Warming.

2.135.3 Monitor the Unit 1 SM piping for water hammer.

2.l35.4 Notify the Control Room Supervisor to monitor Unit 2 Reactor Power, Generator MW, and AS header pressure while performing the following step.

2.135.5 Slowly close lAS-4 (Main Steam to Aux Steam Header Control Bypass) (TB-610, IM-32).

2.136 IF the NC System heatup was performed with the MSIV's closed, open the MSIV's as follows:

CAUTION: Main steam line drains shall be open for at least 15 minutes prior to opening MSIVs or MSIV Bypasses.

-- 2.136.1 Open the following valves:

o ISM-132 (SM Equalization Hdr Trap T-05 Byp) (TB-594, IH-32) o ISM-139 (SM Equalization Hdr Trap T-06 Byp).(TB-594, IH-32)

-- 2.136.2 After 15 minutes, close the following valves:

o ISM-132 (SM Equalization Hdr Trap T-05 Byp) o ISM~139 (SM Equalization Hdr Trap T-06 Byp).

NOTE:

The following step will take a minimum of 30 minutes to perform. The procedure may continue while performing Step 2.136.3 2.l36.3 Equalize pressure across and open the MSIV's per OP/I/A/62501006 (Main Steam).

.1 Unit Startup 2.137 Establish automatic steam dump control as follows: (R.M.)

D 2.137.1 Adjust the "Stm Dump Ctrl" setpoint to 1092 psig.

D 2.137.2 Ensure MSIV's are open per Step 2.136.3.

OP/I/A/61001001 Page 44 of66 D 2.137.3 Ensure T-AVG is less than or equal to 557°F per Step 2.134.1.

D 2.137.4 Place the "Stm Dump Ctrl" in auto.

2.138 Turn the following switches to the "ON" position:

D "Steam Dump Intlk Byp Tm A" D "Steam Dump Intlk Byp Tm B".

2.139 WHEN MSIV's are open verify the steam dumps maintain approximately 1090 psig (approximately 557° T-AVG).

2.140 Ensure S/G PORV's in "AUTO".

2.141 Verify S/G( s) reverse purge flow by performing the following:

D 2.141.1 Record the temperature for the following OAC points: (OAC Group Display GD OPCFTEMP)

  • CIA0141 (S/G A After CF Isol Vlv Line Temp)
  • CIA0125 (S/G B After CF Isol Vlv Line Temp)
  • CIA0275 (S/G C After CF Isol Vlv Line Temp)
  • CIA0815 (S/G DAfter CF Isol Vlv Line Temp)

D 2.141.2 Compare the values recorded above to the values recorded in Steps 2.77.15.7,2.100.1,2.114.1 and 2.122.1 to verify reverse purge (increasing temperature).

D 2.141.3 IF no sign of reverse purge, determine what is causing the loss of reverse purge and correct the problem.

D 2.141.4 Monitor OAC Group Display OPCFTEMP for increasing temperatures as a sign of reverse purge while continuing with the procedure..1 Unit Startup 2.137 Establish automatic steam dump control as follows: (R.M.)

o 2.137.1 Adjust the "Stm Dump Ctrl" setpoint to 1092 psig.

o 2.137.2 Ensure MSN's are open per Step 2.136.3.

OP!l/A/61 00/00 1 Page 44 of66 o 2.137.3 Ensure T-AVG is less than or equal to 557°F per Step 2.134.1.

o 2.137.4 Place the "Stm Dump Ctrl" in auto.

2.138 Tum the following switches to the "ON" position:

o "Steam Dump Intlk Byp Tm A" o "Steam Dump Intlk Byp Tm B".

2.139 WHEN MSN's are open verify the steam dumps maintain approximately 1090 psig (approximately 557° T-AVG).

2.140 Ensure S/G PORV's in "AUTO".

2.141 Verify S/G(s) reverse purge flow by performing the following:

o 2.141.1 Record the temperature for the following OAC points: (OAC Group Display GD OPCFTEMP)

  • CIA0141 (S/G A After CF Isol Vlv Line Temp)
  • CIA0125 (S/G B After CF Isol Vlv Line Temp)
  • CIA0275 (S/G C After CF Isol Vlv Line Temp)
  • CIA0815 (S/G DAfter CF Isol Vlv Line Temp)

o 2.141.2 Compare the values recorded above to the values recorded in Steps 2.77.15.7, 2.100.1, 2.114.1 and 2.122.1 to verify reverse purge (increasing temperature).

o 2.141.3 IF no sign of reverse purge, determine what is causing the loss of reverse purge and correct the problem.

o 2.141.4 Monitor OAC Group Display OPCFTEMP for increasing temperatures as a sign of reverse purge while continuing with the procedure.

CATAWBA NUCLEAR STATION INITIAL LICENSE EXAMINATION JOB PERFORMANCE MEASURE Transfer Emergency Core Cooling System to Hot Leg Recirculation JPM09 F CANDIDATE EXAMINER JPM09 F Page 1 of 12 CATAWBA NUCLEAR STATION INITIAL LICENSE EXAMINATION JOB PERFORMANCE MEASURE Transfer Emergency Core Cooling System to Hot Leg Recirculation JPM09 F CANDIDATE EXAMINER JPM09 F Page 1 of 12

CATAWBA NUCLEAR STATION INITIAL LICENSE EXAMINATION JOB PERFORMANCE MEASURE Transfer Emergency Core Cooling System to Hot Leg Recirculation Alternate Path:

YES Facility JPM #:

NI-098 KIA Rating(s):

SYS006 A4.05 (3.9/3.8) Ability to manually operate and/or monitor in the control room: Transfer of ECCS flowpaths prior to recirculation.

Task Standard:

Hot leg recirculation flow indicated from both trains of the ND system.

Preferred Evaluation Simulator:

Preferred Evaluation Perform Simulator X

In-Plant __ _

Perform _~X~ Simulate __ _

References:

EP/1/A15000/ES-1.4 (Transfer to Hot Leg Recirculation) revision 005 Validation Time: 15 min.

Time Critical: No

=======================================================================

Candidate:

Time Start:

NAME Time Finish:

Performance Rating: SAT UNSAT Performance Time Examiner:

1 NAME SIGNATURE DATE

=======================================================================

COMMENTS JPM09 F Page 2 of 12 CATAWBA NUCLEAR STATION INITIAL LICENSE EXAMINATION JOB PERFORMANCE MEASURE Transfer Emergency Core Cooling System to Hot Leg Recirculation Alternate Path:

YES Facility JPM #:

NI-098 KIA Rating(s):

SYS006 A4.05 (3.9/3.8) Ability to manually operate and/or monitor in the control room: Transfer of ECCS f10wpaths prior to recirculation.

Task Standard:

Hot leg recirculation flow indicated from both trains of the ND system.

Preferred Evaluation Simulator:

Preferred Evaluation Perform Simulator X

In-Plant __ _

Perform _....:...X"'----

Simulate __ _

References:

EP/1/A/5000/ES-1.4 (Transfer to Hot Leg Recirculation) revision 005 Validation Time: 15 min.

Time Critical: No

=======================================================================

Candidate:

Time Start:

NAME Time Finish:

Performance Rating:

SAT UNSAT Performance Time Examiner:

1 NAME SIGNATURE DATE

=======================================================================

COMMENTS JPM09 F Page 2 of 12

SIMULATOR SETUP SHEET

1. Reset to any 100% power IC set.
2. Insert MAL-NC013A (NC COLD LEG LEAK) VALUE 27.5
3. Complete required steps of E-O, E-1 and ES-1.3
4. Once swap to CLR is complete insert the following:

MAL-NI001A (SI Pump A failure), VALUE = BOTH MAL-NI001 B (SI Pump B failure), VALUE= MANUAL

5. Freeze simulator and write to a snap.

IC SELECTED _____ _

SIMULATOR OPERATOR INSTRUCTIONS:

None Tools/Equipment/Procedures Needed:

EP/1/A/5000/ES-1.4 (Transfer to Hot Leg Recirculation) revision 005 JPM09 F Page 3 of 12 SIMULATOR SETUP SHEET

1. Reset to any 100% power IC set.
2. Insert MAL-NC013A (NC COLD LEG LEAK) VALUE 27.5
3. Complete required steps of E-O, E-1 and ES-1.3
4. Once swap to CLR is complete insert the following:

MAL-NI001A (SI Pump A failure), VALUE = BOTH MAL-NI001 B (SI Pump B failure), VALUE= MANUAL

5. Freeze simulator and write to a snap.

IC SELECTED _____ _

SIMULATOR OPERATOR INSTRUCTIONS:

None Tools/Equipment/Procedures Needed:

EP/1/A/5000/ES-1.4 (Transfer to Hot Leg Recirculation) revision 005 JPM09 F Page 3 of 12

READ TO OPERATOR DIRECTION TO TRAINEE:

I will explain the initial conditions, and state the task to be performed. All control room steps shall be performed for this JPM, including any required communications. I will provide initiating cues and reports on other actions when directed by you. Ensure you indicate to me when you understand your assigned task. To indicate that you have completed your assigned task return the handout sheet I provided you.

INITIAL CONDITIONS:

A LOCA on the NC System has been in progress for 6 hours6.944444e-5 days <br />0.00167 hours <br />9.920635e-6 weeks <br />2.283e-6 months <br />. The Emergency Core Cooling System (ECCS) is in the Cold Leg Recirculation lineup. 1A NI pump failed to start automatically and could not be manually started.

INITIATING CUES:

Transfer the ECCS System to Hot Leg Recirculation per EP/1/A/5000/ES-1.4 (Transfer to Hot Leg Recirculation)

JPM09 F Page 4 of 12 READ TO OPERATOR DIRECTION TO TRAINEE:

I will explain the initial conditions, and state the task to be performed. All control room steps shall be performed for this JPM, including any required communications. I will provide initiating cues and reports on other actions when directed by you. Ensure you indicate to me when you understand your assigned task. To indicate that you have completed your assigned task return the handout sheet I provided you.

INITIAL CONDITIONS:

A LOCA on the NC System has been in progress for 6 hours6.944444e-5 days <br />0.00167 hours <br />9.920635e-6 weeks <br />2.283e-6 months <br />. The Emergency Core Cooling System (ECCS) is in the Cold Leg Recirculation lineup. 1A NI pump failed to start automatically and could not be manually started.

INITIATING CUES:

Transfer the ECCS System to Hot Leg Recirculation per EP/1/A/5000/ES-1.4 (Transfer to Hot Leg Recirculation)

JPM09 F Page 4 of 12

START TIME: __

STEP 1a:

Align NI pumps for Hot Leg Recirc as follows:

SAT

a. Stop NI Pump 1A.

STANDARD:

Notes pump is off.

UNSAT COMMENTS:

STEP 1b:

b. Close 1 NI-118A (NI Pump 1A C-Leg Inj Isol).

SAT STANDARD:

Depresses the GREEN "CLOSED" pushbutton and verifies the GREEN "CLSD" light is LIT.

UNSAT COMMENTS:

STEP 1.c:

Place "PWR DISCON FOR 1NI-121A" switch in "ENABLE" SAT STANDARD: Places "PWR DISCON FOR 1NI-121A" switch to the "ENABLE" position.

COMMENTS UNSAT STEP 1.d:

SAT Open 1 NI-121A (NI To C-Legs Inj Hdr Isol).

STANDARD:

Depresses the RED "OPEN" pushbutton and verifies the RED "OPEN" light is LIT.

UNSAT COMMENTS JPM09 F Page 5 of 12 START TIME: __

STEP 1a:

Align NI pumps for Hot Leg Recirc as follows:

SAT

a. Stop NI Pump 1A.

STANDARD:

Notes pump is off.

UNSAT COMMENTS:

STEP 1b:

b. Close 1NI-118A (NI Pump 1A C-Leg Inj Isol).

SAT STANDARD:

Depresses the GREEN "CLOSED" pushbutton and verifies the GREEN "CLSD" light is LIT.

UNSAT COMMENTS:

STEP 1.c:

Place "PWR DISCON FOR 1NI-121A" switch in "ENABLE" SAT STANDARD: Places "PWR DISCON FOR 1 NI-121A" switch to the "ENABLE" position.

COMMENTS UNSAT STEP 1.d:

SAT Open 1NI-121A (NI To C-Legs Inj Hdr Isol).

STANDARD:

Depresses the RED "OPEN" pushbutton and verifies the RED "OPEN" light is LIT.

UNSAT COMMENTS JPM09 F Page 5 of 12

STEP 1.1:

SAT I. WHEN 1 NI-121A is open, THEN start NI Pump 1A.

STANDARD: Depresses the red "ON" pushbutton and notes it will not start and continues.

UNSAT COMMENTS STEP 1.f:

f. Stop NI Pump 1 B.

SAT STANDARD:

Depressed the GREEN "OFF" pushbutton and verified the GREEN "OFF" light is lit.

UNSAT COMMENTS STEP 1.g:

g. Close 1NI-150B (NI Pump 1B C-Leg Inj Isol).

SAT STANDARD: Depresses the GREEN "CLOSED" pushbutton and verifies the GREEN "CLSD" light is LIT.

UNSAT COMMENTS STEP 1.h:

Place "PWR DISCON FOR 1NI-162A" switch in "ENABLE" SAT STANDARD: Places "PWR DISCON FOR 1 NI-162A" switch to the "ENABLE" position.

COMMENTS UNSAT JPM09 F Page 6 of 12 STEP 1.1:

SAT I. WHEN 1 NI-121A is open, THEN start NI Pump 1A.

STANDARD: Depresses the red "ON" pushbutton and notes it will not start and continues.

UNSAT COMMENTS STEP 1.f:

f. Stop NI Pump 1 B.

SAT STANDARD:

Depressed the GREEN "OFF" pushbutton and verified the GREEN "OFF" light is lit.

UNSAT COMMENTS STEP 1.9:

g. Close 1NI-150B (NI Pump 1B C-Leg Inj Isol).

SAT STANDARD: Depresses the GREEN "CLOSED" pushbutton and verifies the GREEN "CLSD" light is LIT.

UNSAT COMMENTS STEP 1.h:

Place "PWR DISCON FOR 1NI-162A" switch in "ENABLE" SAT STANDARD: Places "PWR DISCON FOR 1 NI-162A" switch to the "ENABLE" position.

COMMENTS UNSAT JPM09 F Page 6 of 12

STEP 1.i:

SAT Close 1NI-162A (NI To C-Legs Inj Hdr Isol).

STANDARD: Depresses the GREEN "CLOSED" pushbutton and verifies the GREEN "CLSD" light is LIT.

UNSAT COMMENTS STEP 1.j:

j. Place "PWR DISCON FOR 1NI-152B" switch in "ENABLE".

SAT STANDARD: Places "PWR DISCON FOR 1NI-152B" switch to the "ENABLE" position UNSAT COMMENTS STEP 1.k:

k. Open 1NI-152B (NI Pump 1B To H-Legs A&D).

SAT STANDARD: Depresses the RED "OPEN" pushbutton and notes the RED "OPEN" light is lit.

UNSAT COMMENTS STEP 1.1:

I. WHEN 1NI-152B is open, THEN start NI Pump 1B.

SAT STANDARD: Depresses the red "ON" pushbutton and notes it will not start and continues.

UNSAT COMMENTS JPM09 F Page 7 of 12 STEP 1.i:

SAT Close 1NI-162A (NI To C-Legs Inj Hdr Isol).

STANDARD: Depresses the GREEN "CLOSED" pushbutton and verifies the GREEN "CLSD" light is LIT.

UNSAT COMMENTS STEP 1.j:

j. Place "PWR DISCON FOR 1 N 1-152B" switch in "ENABLE".

SAT STANDARD: Places "PWR DISCON FOR 1NI-152B" switch to the "ENABLE" position UNSAT COMMENTS STEP 1.k:

k. Open 1 NI-152B (NI Pump 1 B To H-Legs A&D).

SAT STANDARD: Depresses the RED "OPEN" pushbutton and notes the RED "OPEN" light is lit.

UNSAT COMMENTS STEP 1.1:

I. WHEN 1NI-152B is open, THEN start NI Pump 1B.

SAT STANDARD: Depresses the red "ON" pushbutton and notes it will not start and continues.

UNSAT COMMENTS JPM09 F Page 7 of 12

STEP 2:

CRITICAL STEP Verify flow from at least one train of NI.

SAT STANDARD: Notes that both NI pumps are off and goes to RNO.

COMMENTS UNSAT STEP 2 RNO:

Perform the following:

SAT

a. Notify station management that NI flow not indicated.
b. GO TO Step 4.

STANDARD: Notifies management that no NI flow is indicated and goes to UNSAT step 4.

EXAMINER NOTE: When management is notified, repeat back what they say.

COMMENTS STEP 4a:

Align ND pumps for Hot Leg Recirc as follows:

SAT

a. Verify the following valves - CLOSED.
  • 1ND-1B (ND Pump 1A Suct Frm Loop B)
  • 1 ND-2A (ND Pump 1A Suct Frm Loop B)
  • 1 ND-36B (ND Pump 1 B Suct Frm Loop C)

UNSAT

  • 1 ND-37 A (ND Pump 1 B Suct Frm Loop C)
  • 1 ND-32A (ND Train 1 A Hot Leg Inj Isol)
  • 1 ND-65B (ND Train 1 B Hot Leg Inj Isol).

STANDARD: All valves should be noted closed.

COMMENTS JPM09 F Page 8 of 12 STEP 2:

CRITICAL STEP Verify flow from at least one train of NI.

SAT STANDARD: Notes that both NI pumps are off and goes to RNO.

COMMENTS UNSAT STEP 2 RNO:

Perform the following:

SAT

a. Notify station management that NI flow not indicated.
b. GO TO Step 4.

STANDARD: Notifies management that no NI flow is indicated and goes to UNSAT step 4.

EXAMINER NOTE: When management is notified, repeat back what they say.

COMMENTS STEP 4a:

Align ND pumps for Hot Leg Recirc as follows:

SAT

a. Verify the following valves - CLOSED.
  • 1 ND-1 B (ND Pump 1A Suct Frm Loop B)
  • 1 ND-2A (ND Pump 1A Suct Frm Loop B)
  • 1 ND-36B (ND Pump 1 B Suct Frm Loop C)

UNSAT

  • 1 ND-37A (ND Pump 1 B Suet Frm Loop C)
  • 1 ND-32A (ND Train 1 A Hot Leg Inj Isol)
  • 1 ND-65B (ND Train 1 B Hot Leg Inj Isol).

STANDARD: All valves should be noted closed.

COMMENTS JPM09 F Page 8 of 12

STEP 4b:

CRITICAL STEP

b. Place "PWR DISCON FOR 1NI-183B" in "ENABLE".

SAT STANDARD: Places "PWR DISCON FOR 1NI-183B" to the "ENABLE" position.

COMMENTS UNSAT STEP 4c:

CRITICAL STEP Open 1 NI-183B (ND Hdr A&B Hot Leg Inj Isol).

SAT STANDARD: Depresses RED "OPEN" pushbutton and verifies RED "OPEN" light is LIT.

COMMENTS UNSAT STEP 4d:

CRITICAL STEP

e. For A ND Train:
1) Verify 1 NS-43A (ND Pmp 1A To Cont Spray Hdr) - CLOSED.
2) Place "PWR DISCON FOR 1NI-173A" switch in "ENABLE".

SAT

3) Close 1NI-173A (ND Hdr 1A To Cold Legs A&B).
4) Open 1ND-32A (ND Train 1A Hot Leg Inj Isol).

STANDARD:

UNSAT

1. Notes 1 NS-43A is closed.
2. Places "PWR DISCON FOR 1NI-173A" switch to the "ENABLE" position.
3. Depresses the GREEN "CLOSE" pushbutton on 1 NI-173A and verifies the GREEN "CLSD" light is LIT.
4. Depresses the RED "OPEN" pushbutton for 1 ND-32A and verifies the RED "OPEN" light is LIT.

COMMENTS JPM09 F Page 9 of 12 STEP 4b:

CRITICAL STEP

b. Place "PWR DISCON FOR 1NI-183B" in "ENABLE".

SAT STANDARD: Places "PWR DISCON FOR 1NI-183B" to the "ENABLE" position.

COMMENTS UNSAT STEP 4c:

CRITICAL STEP Open 1NI-183B (ND Hdr A&B Hot Leg Inj Isol).

SAT STANDARD: Depresses RED "OPEN" pushbutton and verifies RED "OPEN" light is LIT.

COMMENTS UNSAT STEP 4d:

CRITICAL STEP

e. For A ND Train:
1) Verify 1 NS-43A (ND Pmp 1A To Cont Spray Hdr) - CLOSED.
2) Place "PWR DISCON FOR 1 NI-173A" switch in "ENABLE".

SAT

3) Close 1 NI-173A (ND Hdr 1A To Cold Legs A&B).
4) Open 1ND-32A (ND Train 1A Hot Leg Inj Isol).

STANDARD:

UNSAT

1. Notes 1 NS-43A is closed.
2. Places "PWR DISCON FOR 1 NI-173A" switch to the "ENABLE" position.
3. Depresses the GREEN "CLOSE" pushbutton on 1 NI-173A and verifies the GREEN "CLSD" light is LIT.
4. Depresses the RED "OPEN" pushbutton for 1 ND-32A and verifies the RED "OPEN" light is LIT.

COMMENTS JPM09 F Page 9 of 12

STEP 4e:

e. For B ND Train:
1) Verify 1 NS-38B (ND Pmp 1 B To Cont Spray Hdr) - CLOSED.
2) Place "PWR DISCON FOR 1 NI-178B" switch in "ENABLE".
3) Close 1NI-178B (ND Hdr 1B To Cold legs A&B).
4) Open 1ND-65B (ND Train 1B Hot leg Inj Isol).

STANDARD:

1. Notes 1 NS-38B is closed.
2. Places "PWR DISCON FOR 1 NI-178B" switch to the "ENABLE" position.
3. Depresses the GREEN "CLOSE" pushbutton on 1 NI-178B and verifies the GREEN "ClSD" light is LIT.
4. Depresses the RED "OPEN" pushbutton for 1 ND-65B and verifies the RED "OPEN" light is LIT.

COMMENTS STEP 5:

Ensure Monitor Light Panel Group 6 HlR lights - LIT.

STANDARD: All lights are noted to be in the correct state.

COMMENTS STEP 6:

Verify flow to NC hot legs from at least one train of ND.

STANDARD: Notes flow to the hot legs with both 1A and 1 B ND pump in service.

COMMENTS JPM09 F CRITICAL STEP SAT UNSAT SAT UNSAT SAT UNSAT Page 10 of 12 STEP 4e:

e. For B ND Train:
1) Verify 1 NS-38B (ND Pmp 1 B To Cont Spray Hdr) - CLOSED.
2) Place "PWR DISCON FOR 1 NI-178B" switch in "ENABLE".
3) Close 1 NI-178B (ND Hdr 1 B To Cold Legs A&B).
4) Open 1 ND-65B (ND Train 1 B Hot Leg Inj Isol).

STANDARD:

1. Notes 1 NS-38B is closed.
2. Places "PWR DISCON FOR 1NI-178B" switch to the "ENABLE" position.
3. Depresses the GREEN "CLOSE" pushbutton on 1 NI-178B and verifies the GREEN "CLSD" light is LIT.
4. Depresses the RED "OPEN" pushbutton for 1 ND-65B and verifies the RED "OPEN" light is LIT.

COMMENTS STEP 5:

Ensure Monitor Light Panel Group 6 HLR lights - LIT.

STANDARD: All lights are noted to be in the correct state.

COMMENTS STEP 6:

Verify flow to NC hot legs from at least one train of ND.

STANDARD: Notes flow to the hot legs with both 1A and 1B ND pump in service.

COMMENTS JPM09 F CRITICAL STEP SAT UNSAT SAT UNSAT SAT UNSAT Page 10 of 12

STEP 7:

RETURN TO procedure and step in effect.

SAT STANDARD: Reads step.

COMMENTS UNSAT This JPM is complete.

TIME STOP: __

JPM09 F Page 11 of 12 STEP 7:

RETURN TO procedure and step in effect.

SAT STANDARD: Reads step.

COMMENTS UNSAT This JPM is complete.

TIME STOP: __

JPM09 F Page 11 of 12

CANDIDATE CUE SHEET (TO BE RETURNED TO EXAMINER UPON COMPLETION OF TASK)

INITIAL CONDITIONS:

A LOCA on the NC System has been in progress for 6 hours6.944444e-5 days <br />0.00167 hours <br />9.920635e-6 weeks <br />2.283e-6 months <br />. The Emergency Core Cooling System (ECCS) is in the Cold Leg Recirculation lineup. 1A NI pump failed to start automatically and could not be manually started.

INITIATING CUES:

Transfer the ECCS System to Hot Leg Recirculation per EP/1/A/5000/ES-1.4 (Transfer to Hot Leg Recirculation)

CANDIDATE CUE SHEET (TO BE RETURNED TO EXAMINER UPON COMPLETION OF TASK)

INITIAL CONDITIONS:

A LOCA on the NC System has been in progress for 6 hours6.944444e-5 days <br />0.00167 hours <br />9.920635e-6 weeks <br />2.283e-6 months <br />. The Emergency Core Cooling System (ECCS) is in the Cold Leg Recirculation lineup. 1A NI pump failed to start automatically and could not be manually started.

INITIATING CUES:

Transfer the ECCS System to Hot Leg Recirculation per EP/1/A/5000/ES-1.4 (Transfer to Hot Leg Recirculation)

I I

Duke Power Company Procedure No.

Catawba Nuclear Station EP/I/A/5000/ES-1.4 Revision No.

005 Transfer to Hot Leg Recirculation Electronic Reference No.

Continuous Use CPOO94CX PERFORMANCE I

  • * * * * * * * *
  • UNCONTROLLED FOR PRINT * * * * * * * * * *

(ISSUED) - PDF Format Duke Power Company Procedure No.

Catawba Nuclear Station EP/I/A/5000/ES-1.4 Revision No.

005 Transfer to Hot Leg Recirculation Electronic Reference No.

Continuous Use CPOO94CX PERFORMANCE I

  • * * * * * * * *
  • UNCONTROLLED FOR PRINT * * * * * * * * * *

(ISSUED) - PDF Format

CNS TRANSFER TO HOT LEG RECIRCULATION PAGE NO.

EP/1/A15000/ES-1.4 1 of 5 Revision 5 A. Purpose This procedure provides the necessary instructions for transferring the safety injection system to Hot Leg Recirculation.

B. Symptoms or Entry Conditions This procedure is entered from:

a. EP/1/A15000/E-1 (Loss Of Reactor Or Secondary Coolant), Step 20, when the specified time interval has elapsed.
b. When a decision is made, based upon the recommendation of station management, that transfer to Hot Leg Recirc is required. Transfer to Hot Leg Recirc might be required eventually, after transferring to Cold Leg Recirc during the implementation of:
  • EP/1/A15000/ES-1.2 (Post LOCA Cooldown And Depressurization)

CNS TRANSFER TO HOT LEG RECIRCULATION PAGE NO.

EP/1/A/SOOO/ES-1.4 1 of S Revision S A. Purpose This procedure provides the necessary instructions for transferring the safety injection system to Hot Leg Recirculation.

B. Symptoms or Entry Conditions This procedure is entered from:

a. EP/1/A/SOOO/E-1 (Loss Of Reactor Or Secondary Coolant), Step 20, when the specified time interval has elapsed.
b. When a decision is made, based upon the recommendation of station management, that transfer to Hot Leg Recirc is required. Transfer to Hot Leg Recirc might be required eventually, after transferring to Cold Leg Recirc during the implementation of:
  • EP/1/A/SOOO/ES-1.2 (Post LOCA Cooldown And Depressurization)

CNS TRANSFER TO HOT LEG RECIRCULATION PAGE NO.

EP/11A15000/ES-1.4 ACTION/EXPECTED RESPONSE C. Operator Actions

1.

Align NI pumps for Hot Leg Recirc as follows:

a. Stop NI Pump 1A.
b. Close 1NI-118A(NI Pump 1AC-Leg Inj Isol}.
c. Place "PWR DISCON FOR 1NI-121A" switch in "ENABLE".
d. Open 1 NI-121A (NI Pump 1A To H-Legs B&C).
e. WHEN 1NI-121A is open, THEN start NI Pump 1A.
f.

Stop NI Pump 1 B.

_ g. Close 1NI-150B (NI Pump 1B C-Leg Inj Isol).

h. Place "PWR DISCON FOR 1NI-162A" switch in "ENABLE".
i.

Close 1NI-162A (NI To C-Legs Inj Hdr Isol).

2 of 5 Revision 5 RESPONSE NOT OBTAINED

b. Perform the following:

_ 1} Dispatch operator to close 1 N 1-118A (NI Pump 1A C-Leg Inj Isol)

(AB-553, GG-HH, 53-54, Rm 235).

_ 2} WHEN 1NI-118A is closed, THEN perform steps 1.c through 1.e.

_ 3} GO TO Step 1.f.

d. Dispatch operator to open 1NI-121A (NI Pump 1A To H-Legs B&C) (AB-5?2, FF-GG, 52, Rm 318).
g. Perform the following:

_ 1} Dispatch operator to close 1 NI-150B (NI Pump 1 B C-Leg Inj Isol)

(AB-550, HH-JJ, 53-54, Rm 234).

_ 2} WHEN 1NI-150B is closed, THEN perform steps 1.h through 1.1.

_ 3} GO TO Step 2.

i.

Dispatch operator to close 1NI-162A (NI To C-Legs Inj Hdr Isol) (AB-56?, JJ-51, Rm 318A).

CNS TRANSFER TO HOT LEG RECIRCULATION PAGE NO.

EP/1/A15000/ES-1.4 ACTION/EXPECTED RESPONSE C. Operator Actions

1.

Align NI pumps for Hot Leg Recirc as follows:

a. Stop NI Pump 1A.
b. Close 1 NI-118A (NI Pump 1A C-Leg Inj Isol).
c. Place "PWR DISCON FOR 1NI-121A" switch in "ENABLE".
d. Open 1 NI-121A (NI Pump 1A To H-Legs B&C).
e. WHEN 1NI-121A is open, THEN start NI Pump 1A.
f.

Stop NI Pump 1 B.

_ g. Close 1NI-150B (NI Pump 1B C-Leg Inj Isol).

h. Place "PWR DISCON FOR 1NI-162A" switch in "ENABLE".
i.

Close 1 NI-162A (NI To C-Legs Inj Hdr Isol).

2 of 5 Revision 5 RESPONSE NOT OBTAINED

b. Perform the following:

_ 1} Dispatch operator to close 1 N 1-118A (NI Pump 1A C-Leg Inj Isol)

(AB-553, GG-HH, 53-54, Rm 235).

_ 2} WHEN 1NI-118A is closed, THEN perform steps 1.c through 1.e.

_ 3} GO TO Step 1.f.

d. Dispatch operator to open 1NI-121A (NI Pump 1A To H-Legs B&C) (AB-572, FF-GG, 52, Rm 318).
g. Perform the following:

_ 1} Dispatch operator to close 1 NI-150B (NI Pump 1 B C-Leg Inj Isol)

(AB-550, HH-JJ, 53-54, Rm 234).

_ 2} WHEN 1NI-150B is closed, THEN perform steps 1.h through 1.1.

_ 3} GO TO Step 2.

i.

Dispatch operator to close 1 NI-162A (NI To C-Legs Inj Hdr Isol) (AB-56?, JJ-51,

Rm 318A).

CNS TRANSFER TO HOT LEG RECIRCULATION PAGE NO.

EP/1/A/5000/ES-1.4 ACTION/EXPECTED RESPONSE

1. (Continued)

_ j.

Place "PWR OISCON FOR 1NI-152B" switch in "ENABLE".

k. Open 1 NI-152B (NI Pump 1 B To H-Legs A&O).

I.

WHEN 1NI-152B is open, THEN start NI Pump 1B.

2.

Verify flow from at least one train of NI.

3.

RETURN TO Procedure and step in effect.

4.

Align NO pumps for Hot Leg Recirc as follows:

a. Verify the following valves - CLOSED.
  • 1NO-1B (NO Pump 1A Suct Frm Loop B)
  • 1 NO-2A (NO Pump 1A Suct Frm Loop B)
  • 1 NO-36B (NO Pump 1 B Suct Frm Loop C)
  • 1 NO-37 A (NO Pump 1 B Suct Frm Loop C)
  • 1 NO-32A (NO Train 1A Hot Leg Inj Isol)
  • 1 NO-65B (NO Train 1 B Hot Leg Inj 1501).
b. Place "PWR OISCON FOR 1NI-183B" in "ENABLE".

3 of 5 Revision 5 RESPONSE NOT OBTAINED

k. Dispatch operator to open 1 N 1-152B (NI Pump 1 B To H-Legs A&O) (AB-580, GG-HH, 52-53, Rm 419).

Perform the following:

a. Notify station management that NI flow not indicated.
b. GO TO Step 4.
a. Perform the following:

_ 1) Contact station management for guidance to align NI or NO for Hot Leg Recirc.

_ 2) RETURN TO Procedure and step in effect.

CNS TRANSFER TO HOT LEG RECIRCULATION PAGE NO.

EP/1/A/5000/ES-1.4 ACTION/EXPECTED RESPONSE

1. (Continued)

_ j.

Place "PWR DISCON FOR 1NI-152B" switch in "ENABLE".

k. Open 1NI-152B (NI Pump 1B To H-Legs A&D).

I.

WHEN 1NI-152B is open, THEN start NI Pump 1B.

2.

Verify flow from at least one train of NI.

3.

RETURN TO Procedure and step in effect.

4.

Align NO pumps for Hot Leg Recirc as follows:

a. Verify the following valves - CLOSED.
  • 1 ND-1 B (NO Pump 1A Suct Frm Loop B)
  • 1ND-2A (NO Pump 1A Suct Frm Loop B)
  • 1 ND-36B (NO Pump 1 B Suct Frm Loop C)
  • 1 ND-37A (NO Pump 1 B Suct Frm Loop C)
  • 1 ND-32A (NO Train 1A Hot Leg Inj Isol)
  • 1 ND-65B (NO Train 1 B Hot Leg Inj Isol).
b. Place "PWR DISCON FOR 1NI-183B" in "ENABLE".

3 of 5 Revision 5 RESPONSE NOT OBTAINED

k.

Dispatch operator to open 1 N 1-152B (NI Pump 1 B To H-Legs A&D) (AB-580, GG-HH, 52-53, Rm 419).

Perform the following:

a. Notify station management that NI flow not indicated.
b. GO TO Step 4.
a. Perform the following:
1) Contact station management for guidance to align NI or NO for Hot Leg Recirc.

_ 2) RETURN TO Procedure and step in effect.

CNS TRANSFER TO HOT LEG RECIRCULATION PAGE NO.

EP/1/A15000/ES-1.4 ACTION/EXPECTED RESPONSE

4. (Continued)
c. Open 1 NI-183B (ND Hdr A&B Hot Leg Inj Isol).
d. For A ND Train:

1} Verify 1 NS-43A (ND Pmp 1A To Cont Spray Hdr) - CLOSED.

_ 2} Place "PWR DISCON FOR 1 NI-173A" switch in "ENABLE".

_ 3} Close 1 NI-173A (ND Hdr 1A To Cold Legs C&D).

_ 4} Open 1ND-32A (ND Train 1A Hot Leg Inj Isol).

RESPONSE NOT OBTAINED

c. Perform the following:

1} Close ND train discharge crossovers:

4 of 5 Revision 5

  • 1 ND-32A (ND Train 1A Hot Leg Inj Isol)
  • 1 ND-65B (ND Train 1 B Hot Leg Inj Isol).

_ 2} Open 1 NI-173A (ND Hdr 1A To Cold Legs C&D).

_ 3} Dispatch operator to open 1 NI-183B (ND Hdr A&B Hot Leg Inj Isol)

(AB-571, EE-FF, 52-53, Rm 333A).

_ 4} WHEN 1NI-183B is open, THEN perform Step 4.

_ 5} GO TO Step 5.

1} GO TO Step 4.e.

_ 3} Dispatch operator to close 1 NI-173A (ND Hdr 1A To Cold Legs C&D)

(AB-566, HH-52, Rm 318A).

_ 4} Dispatch operator to open 1 ND-32A (ND Train 1A Hot Leg Inj Isol)

(AB-568, LL-MM, 51-52, Rm 434).

CNS TRANSFER TO HOT LEG RECIRCULATION PAGE NO.

EP/1/A/5000/ES-1.4 ACTION/EXPECTED RESPONSE

4. (Continued)
c. Open 1 NI-183B (ND Hdr A&B Hot Leg Inj Isol).
d. For A ND Train:

_ 1} Verify 1 NS-43A (ND Pmp 1A To Cont Spray Hdr) - CLOSED.

_ 2} Place "PWR DISCON FOR 1 NI-173A" switch in "ENABLE".

_ 3} Close 1 NI-173A (ND Hdr 1A To Cold Legs C&D).

_ 4} Open 1ND-32A (ND Train 1A Hot Leg Inj Isol).

RESPONSE NOT OBTAINED

c. Perform the following:

1} Close ND train discharge crossovers:

4 of 5 Revision 5

  • 1 ND-32A (ND Train 1A Hot Leg Inj Isol)
  • 1 ND-65B (ND Train 1 B Hot Leg Inj Isol).

_ 2} Open 1 NI-173A (ND Hdr 1A To Cold Legs C&D).

_ 3} Dispatch operator to open 1 NI-183B (ND Hdr A&B Hot Leg Inj Isol)

(AB-571, EE-FF, 52-53, Rm 333A).

_ 4} WHEN 1NI-183B is open, THEN perform Step 4.

_ 5} GO TO Step 5.

_ 1} GO TO Step 4.e.

_ 3} Dispatch operator to close 1 NI-173A (ND Hdr 1A To Cold Legs C&D)

(AB-566, HH-52, Rm 318A).

_ 4} Dispatch operator to open 1 ND-32A (ND Train 1A Hot Leg Inj Isol)

(AB-568, LL-MM, 51-52, Rm 434).

CNS TRANSFER TO HOT LEG RECIRCULATION PAGE NO.

EP/1/Al5000/ES-1.4 ACTION/EXPECTED RESPONSE

4. (Continued)
e. For B ND Train:
1) Verify 1 NS-38B (ND Pmp 1 B To Cont Spray Hdr) - CLOSED.

_ 2) Place "PWR DISCON FOR 1 NI-178B" switch in "ENABLE".

_ 3) Close 1NI-178B (ND Hdr 1B To Cold Legs A&B).

_ 4) Open 1ND-65B (ND Train 1B Hot Leg Inj Isol).

5.

Ensure Monitor Light Panel Group 6 HLR lights - LIT.

6.

Verify flow to NC hot legs from at least one train of NO.

7.

RETURN TO procedure and step in effect.

50f5 Revision 5 RESPONSE NOT OBTAINED

_ 1) GO TO Step 5.

_ 3) Dispatch operator to close 1NI-178B (ND Hdr 1B To Cold Legs A&B)

(AB-561, FF-GG, 52-53, Rm 318A).

_ 4) Dispatch operator to open 1 ND-65B (ND Train 1 B Hot Leg Inj Isol)

(AB-570, KK-LL, 51-52, Rm 435).

_ Contact station management for guidance to align NO for Hot Leg Recirc.

CNS TRANSFER TO HOT LEG RECIRCULATION PAGE NO.

EP/1/A/5000/ES-1.4 ACTION/EXPECTED RESPONSE

4. (Continued)
e. For B NO Train:
1) Verify 1 NS-38B (NO Pmp 1 B To Cont Spray Hdr) - CLOSED.

_ 2) Place "PWR DISCON FOR 1 NI-178B" switch in "ENABLE".

3) Close 1 NI-178B (NO Hdr 1 B To Cold Legs A&B).

_ 4) Open 1 ND-65B (NO Train 1 B Hot Leg Inj Isol).

5.

Ensure Monitor Light Panel Group 6 HLR lights - LIT.

6.

Verify flow to NC hot legs from at least one train of NO.

7.

RETURN TO procedure and step in effect.

5 of 5 Revision 5 RESPONSE NOT OBTAINED

1) GO TO Step 5.

_ 3) Dispatch operator to close 1 NI-178B (NO Hdr 1 B To Cold Legs A&B)

(AB-561, FF-GG, 52-53, Rm 318A).

_ 4) Dispatch operator to open 1 ND-65B (NO Train 1 B Hot Leg Inj Isol)

(AB-570, KK-LL, 51-52, Rm 435).

_ Contact station management for guidance to align NO for Hot Leg Recirc.

CANDIDATE EXAMINER JPM09 G CATAWBA NUCLEAR STATION INITIAL LICENSE EXAMINATION JOB PERFORMANCE MEASURE JPM09 G Start Reactor Coolant Pump 1 B Page 1 of 15 CANDIDATE EXAMINER JPM09 G CATAWBA NUCLEAR STATION INITIAL LICENSE EXAMINATION JOB PERFORMANCE MEASURE JPM09 G Start Reactor Coolant Pump 1 B Page 1 of 15

CATAWBA NUCLEAR STATION INITIAL LICENSE EXAMINATION JOB PERFORMANCE MEASURE Start Reactor Coolant Pump 1 B Alternate Path:

YES Facility JPM #:

NCP-081 KIA Rating(s}:

SYS003 A 1.01 (2.9/2.9) Ability to manually operate and lor monitor changes in parameters (to prevent exceeding design limits) associated with operating the RCP controls including: RCP vibration.

Task Standard:

Seal injection flow to 1 B NCP is restored to 7-10 gpm. 1 B reactor coolant pum p is tripped when vibration is noted to be greater than NC Pump trip criteria.

Preferred Evaluation Simulator:

Preferred Evaluation Perform Simulator X

In-Plant __ _

Perform _...:..X,,--

Simulate __ _

References:

OP/1/A/6150/002A (Reactor Coolant Pump), Enclosure 4.1 rev 061 DCS Validation Time: 11 min.

Time Critical: No

=======================================================================

Candidate:

Time Start:

NAME Time Finish:

Performance Rating: SAT UNSAT Performance Time Examiner:

I NAME SIGNATURE DATE

=======================================================================

COMMENTS JPM09 G Page 2 of 15 '

CATAWBA NUCLEAR STATION INITIAL LICENSE EXAMINATION JOB PERFORMANCE MEASURE Start Reactor Coolant Pump 1 B Alternate Path:

YES Facility JPM #:

NCP-081 KIA Rating(s):

SYS003 A 1.01 (2.9/2.9) Ability to manually operate and lor monitor changes in parameters (to prevent exceeding design limits) associated with operating the RCP controls including: RCP vibration.

Task Standard:

Seal injection flow to 1 B NCP is restored to 7-10 gpm. 1 B reactor coolant pump is tripped when vibration is noted to be greater than NC Pump trip criteria.

Preferred Evaluation Simulator:

Preferred Evaluation Perform Simulator X

In-Plant __ _

Perform _~X,,--

Simulate __ _

References:

OP/1/A/61501002A (Reactor Coolant Pump), Enclosure 4.1 rev 061 DCS Validation Time: 11 min.

Time Critical: No

=======================================================================

Candidate:

Time Start:

NAME Time Finish:

Performance Rating:

SAT UNSAT Performance Time Examiner:

I NAME SIGNATURE DATE

=======================================================================

COMMENTS JPM09 G Page 2 of 15

SIMULATOR SETUP SHEET

1. Reset to any 100% power IC set.
2. Manually trip the reactor at 1 MC-1.
3. Trip all (4) four NCP breakers at 1MC-10.
4. Reset CA and control flow to maintain S/G levels at 38% N/R level.
5. Place 1 NV-309 in manual and reduce total seal water flow to - 12 gpm
6. Insert MAL-NCP003B (NCP B VIBRATION) Value=30, RAMP=60, EVENT =1, DELAY=150
7. Insert EVENT 1 = x10d185M >400 (NCP B AMPS>400)
8. Freeze simulator and write to a snap.

IC SELECTED _____ _

SIMULATOR OPERATOR INSTRUCTIONS:

ENSURE BENTLEY NEVADA VIBRATION MONITORS ON BACK BOARD ARE RESET AND THAT ALARMS 1AD-6 Al5 AND B/5 ARE CLEARED BETWEEN STUDENTS.

Tools/Equipment/Procedures Needed:

1. OP/11 Al61501002A (Reactor Coolant Pump), Enclosure 4.1 rev 061 DCS JPM09 G Page 3 of 15 SIMULATOR SETUP SHEET
1. Reset to any 100% power IC set.
2. Manually trip the reactor at 1 MC-1.
3. Trip all (4) four NCP breakers at 1MC-10.
4. Reset CA and control flow to maintain S/G levels at 38% N/R level.
5. Place 1 NV-309 in manual and reduce total seal water flow to - 12 gpm
6. Insert MAL-NCP003B (NCP B VIBRATION) Value=30, RAMP=60, EVENT =1, DELAY=150
7. Insert EVENT 1 = x10d185M >400 (NCP B AMPS>400)
8. Freeze simulator and write to a snap.

IC SELECTED _____

SIMULATOR OPERATOR INSTRUCTIONS:

ENSURE BENTLEY NEVADA VIBRATION MONITORS ON BACK BOARD ARE RESET AND THAT ALARMS 1AD-6 A15 AND B/5 ARE CLEARED BETWEEN STUDENTS.

Tools/Equipment/Procedures Needed:

1. OP/1/A/6150/002A (Reactor Coolant Pump), Enclosure 4.1 rev 061 DCS JPM09 G Page 3 of 15

READ TO OPERATOR DIRECTION TO TRAINEE:

I will explain the initial conditions, and state the task to be performed. All control room steps shall be performed for this JPM, including any required communications. I will provide initiating cues and reports on other actions when directed by you. Ensure you indicate to me when you understand your assigned task. To indicate that you have completed your assigned task return the handout sheet I provided you.

INITIAL CONDITIONS:

EP/11A15000/ES-O.2, Natural Circulation Cooldown has been implemented following a Reactor Trip.

Control problems with 1 NV-309 require the valve be operated in manual.

INITIATING CUES:

Start NC Pump 1 B by completing OP/11A161501002A, NC Pump Operation Enclosure 4.1. The Initial Conditions of Enclosure 4.1 have been satisfied.

JPM09 G Page 4 of 15 READ TO OPERATOR DIRECTION TO TRAINEE:

I will explain the initial conditions, and state the task to be performed. All control room steps shall be performed for this JPM, including any required communications. I will provide initiating cues and reports on other actions when directed by you. Ensure you indicate to me when you understand your assigned task. To indicate that you have completed your assigned task return the handout sheet I provided you.

INITIAL CONDITIONS:

EP/1/A/5000/ES-O.2, Natural Circulation Cooldown has been implemented following a Reactor Trip.

Control problems with 1 NV-309 require the valve be operated in manual.

INITIATING CUES:

Start NC Pump 1 B by completing OP/1/A/6150/002A, NC Pump Operation Enclosure 4.1. The Initial Conditions of Enclosure 4.1 have been satisfied.

JPM09 G Page 4 of 15

START TIME: __

CAUTION: An NC Pump shall NOT be started if associated 6.9 KV switchgear is supplying essential switchgear 1 ETA or 1 ETB and switchyard voltage is less than or equal to 223 KV or only one off-site source of power SAT is available.

NOTE: 1. In order to start an NC Pump, the underfrequency condition must be cleared by having at least three of four 6900V breakers (1TA, B, C, D-3)

UNSAT racked in and energized.

2. NC Pump operational configuration restrictions, as follows, will ensure adequate PZR spray for press control, maintain spray line water solid, and prevent thermal stratification of spray line {PIP C-OO-04752}:

-For single pump operation, ensure NC Pump B is in service,

-For multiple pump operation, if NC Pump B is NOT in service, NC Pumps A, C and D will need to be in service, {PIP C-01-4130}

otherwise, Auxiliary PZR spray flow will have to be used.

STANDARD: Acknowledges notes and cautions.

COMMENTS:

STEP 2.1 If Unit 1 is in Mode 5...

STANDARD: This step is N/A per plant conditions.

COMMENTS:

STEP 2.2 If the pump to be started will be the fourth NC pump in service on Unit 1...

SAT STANDARD: This step is N/A per plant conditions.

COMMENTS:

UNSAT JPM09 G Page 5 of 15 START TIME: __

CAUTION: An NC Pump shall NOT be started if associated 6.9 KV switchgear is supplying essential switchgear 1 ETA or 1 ETB and switchyard voltage is less than or equal to 223 KV or only one off-site source of power SAT is available.

NOTE: 1. In order to start an NC Pump, the underfrequency condition must be cleared by having at least three of four 6900V breakers (1TA, B, C, D-3)

UNSAT racked in and energized.

2. NC Pump operational configuration restrictions, as follows, will ensure adequate PZR spray for press control, maintain spray line water solid, and prevent thermal stratification of spray line {PIP C-OO-04752}:

-For single pump operation, ensure NC Pump B is in service,

-For multiple pump operation, if NC Pump B is NOT in service, NC Pumps A, C and D will need to be in service, {PIP C-01-4130}

otherwise, Auxiliary PZR spray flow will have to be used.

STANDARD: Acknowledges notes and cautions.

COMMENTS:

STEP 2.1 If Unit 1 is in Mode 5...

STANDARD: This step is N/A per plant conditions.

COMMENTS:

STEP 2.2 If the pump to be started will be the fourth NC pump in service on Unit 1...

SAT STANDARD: This step is N/A per plant conditions.

COMMENTS:

UNSAT JPM09 G Page 5 of 15

NOTE: If #1 Seal f1P gauge overranged, f1P can be determined using 1 NV125B (Excess Letdn Hx Otlt Ctrl) "VCT" or "NCDT" switch position as follows:

  • "VCT" position: NC Press minus Excess Letdn Hx Otlt Press = #1 Seal f1P
  • "NCDT" position: NC Press minus VCT Press = #1 Seal f1P STANDARD:

Acknowledges note.

COMMENTS:

STEP 2.3:

Verify No. 1 Seal DIP is greater than 200 psig for the pump to be started per the following gauges: (Control Board MC-5) 1 B NCP: 1 NVP 5220 STANDARD:

Verifies seal DIP> 200 psig using stated gauge.

COMMENTS STEP 2.4:

Verify that the standpipe level for the pump to be started is normal by its associated annunciator DARK.

"NCP B #2 SEAL S-PIPE HilLa LVL" 1AD-7 Al2 STANDARD: Notes the stated alarm is DARK.

COMMENTS STEP 2.5:

Verify VCT pressure is equal to or greater than 15 psig.:

STANDARD: Verifies VCT pressure is ~ 15 psig COMMENTS JPM09 G SAT

_UNSAT SAT

_UNSAT SAT UNSAT SAT UNSAT

. Page 6 of 15 NOTE: If #1 Seal LiP gauge overranged, LiP can be deterrDined using 1 NV125B (Excess Letdn Hx Otlt Ctrl) "VCT" or "NCDT" switch position as follows:

  • "VCT" position: NC Press minus Excess Letdn Hx Otlt Press = #1 Seal LiP
  • "NCDT" position: NC Press minus VCT Press = #1 Seal LiP STANDARD:

Acknowledges note.

COMMENTS:

STEP 2.3:

Verify No.1 Seal DIP is greater than 200 psig for the pump to be started per the following gauges: (Control Board MC-5) 1B NCP: 1NVP 5220 STANDARD:

Verifies seal DIP> 200 psig using stated gauge.

COMMENTS STEP 2.4:

Verify that the standpipe level for the pump to be started is normal by its associated annunciator DARK.

"NCP B #2 SEAL S-PIPE HIILO LVL" 1AD-7 A/2 STANDARD: Notes the stated alarm is DARK.

COMMENTS STEP 2.5:

Verify VCT pressure is equal to or greater than 15 psig.:

STANDARD: Verifies VCT pressure is ~ 15 psig COMMENTS JPM09 G SAT UNSAT SAT UNSAT SAT UNSAT SAT UNSAT Page 6 of 15

STEP 2.6:

Verify 7-10 gpm seal injection flow on the pump to be started by the following gauges: (Control Board MC-5) 1 B NCP: 1 NCP5320 STANDARD: Notes seal injection flow is <7 gpm on stated gauge. Adjusts 1 NV-309 in manual to restore seal injection flow to proper range of 7-10 GPM.

EXAMINER CUE: IF student contacts supervision, state:

"Restore seal injection to its required range."

COMMENTS NOTE:

1. If #1 Seal Leakoff Flow rate is < 1.0 gpm, the # 1 Seal Low Flow indication shall be used.
2. If #1 Seal ~P gauge overranged, ~P can be determined using 1 NV125B (Excess Letdn Hx Otlt Ctrl) "VCT" or "NCDT" switch position as follows:
  • "VCT" position: NC Press minus Excess Letdn Hx Otlt Press = #1 Seal

~P

  • "NCDT" position: NC Press minus VCT Press = #1 Seal ~P STANDARD: Acknowledges note.

COMMENTS STEP 2.7 Verify adequate #1 Seal Leakoff Flow on the pump to be started as follows:

2.7.1 Determine required #1 Seal Leakoff Flow from Revised Data Book Figure 26 (NC Pump No. 1 Seal Normal Operating Range).

STANDARD: Determines that based on data book Figure 26 or OAC databook that -1 gpm is the minimum required.

COMMENTS JPM09 G CRITICAL STEP SAT UNSAT SAT UNSAT SAT UNSAT Page 7 of 15 STEP 2.6:

Verify 7-10 gpm seal injection flow on the pump to be started by the following gauges: (Control Board MC-5) 1 B NCP: 1 NCP5320 STANDARD: Notes seal injection flow is <7 gpm on stated gauge. Adjusts 1 NV-309 in manual to restore seal injection flow to proper range of 7-10 GPM.

EXAMINER CUE: IF student contacts supervision, state:

"Restore seal injection to its required range."

COMMENTS NOTE:

1. If #1 Seal Leakoff Flow rate is < 1.0 gpm, the # 1 Seal Low Flow indication shall be used.
2. If #1 Seal llP gauge overranged, llP can be determined using 1 NV125B (Excess Letdn Hx Otlt Ctrl) "VCT" or "NCDT" switch position as follows:
  • "VCT" position: NC Press minus Excess Letdn Hx Otlt Press = #1 Seal llP
  • "NCDT" position: NC Press minus VCT Press = #1 Seal llP STANDARD: Acknowledges note.

COMMENTS STEP 2.7 Verify adequate #1 Seal Leakoff Flow on the pump to be started as follows:

2.7.1 Determine required #1 Seal Leakoff Flow from Revised Data Book Figure 26 (NC Pump No.1 Seal Normal Operating Range).

STANDARD: Determines that based on data book Figure 26 or OAC databook that -1 gpm is the minimum required.

COMMENTS JPM09 G CRITICAL STEP SAT UNSAT SAT UNSAT SAT UNSAT Page 7 of 15

STEP 2.7 2.7.2 Add 0.26 gpm to the minimum required #1 Seal Leakoff Flow of SAT Figure 26 to correct for an expected drop in leakoff flow on pump start (0.20 gpm) and instrument inaccuracy (0.06 gpm).

STANDARD: Determines that the minimum required is 1 +0.26 =1.26 UNSAT COMMENTS STEP 2.7 2.7.3 Obtain the current #1 Seal Leakoff Flow per one of the following:

SAT DCS graphic 6002 (NC PUMPS)

OR Unit 1 Reactor Coolant Pumps graphic (NCPMPALL)

OR UNSAT 1 NVCR5140 (NC Pump Lo Leakoff Flow) (1MC5)

OR 1NVCR5121 (NC Pump Hi Leakoff Flow) (1MC5)

OR Appropriate OAC point C1 A 1376 (NC Pmp B No. 1 Seal Leakoff Lo Flow)

C1A0442 (NC Pmp B No.1 Seal Leakoff Flow)

STANDARD: Notes sealleakoff is within limits.

COMMENTS STEP 2.7 2.7.4 IF the current #1 Seal Leakoff Flow (Step 2.7.3) is less than the SAT minimum flow...

STANDARD: Determines that this step is N/A and continues.

UNSAT COMMENTS JPM09 G Page 8 of 15 STEP 2.7 2.7.2 Add 0.26 gpm to the minimum required #1 Seal Leakoff Flow of SAT Figure 26 to correct for an expected drop in leakoff flow on pump start (0.20 gpm) and instrument inaccuracy (0.06 gpm).

STANDARD: Determines that the minimum required is 1 +0.26 =1.26 UNSAT COMMENTS STEP 2.7 2.7.3 Obtain the current #1 Seal Leakoff Flow per one of the following:

SAT DCS graphic 6002 (NC PUMPS)

OR Unit 1 Reactor Coolant Pumps graphic (NCPMPALL)

OR UNSAT 1 NVCR5140 (NC Pump Lo Leakoff Flow) (1 MC5)

OR 1NVCR5121 (NC Pump Hi Leakoff Flow) (1MC5)

OR Appropriate OAC point C1A1376 (NC Pmp B No.1 Seal Leakoff Lo Flow)

C1A0442 (NC Pmp B No.1 Seal Leakoff Flow)

STANDARD: Notes sealleakoff is within limits.

COMMENTS STEP 2.7 2.7.4 IF the current #1 Seal Leakoff Flow (Step 2.7.3) is less than the SAT minimum flow...

STANDARD: Determines that this step is N/A and continues.

UNSAT COMMENTS JPM09 G Page 8 of 15

STEP 2.7 2.7.5 Verify the indicated #1 Seal Leakoff Flow (Step 2.7.3) is within the range of Revised Data Book Figure 26 as adjusted per Step 2.7.2.

STANDARD: Determines that the sealleakoff is within the normal range.

COMMENTS STEP 2.8:

Verify upper and lower oil pot levels normal, for the pump to be started, via one of the following:

Unit 1 Reactor Coolant Pump graphic (NCPMPALL)

OR Visual Inspection OR Associated annunciators DARK:

"NCP A UPPER/LOWER OIL RESERVOIR LO LEVEL" 1AD-6 F/2 STANDARD: Verifies upper and lower pot levels normal NCP GRAPHIC or Visual inspection (local) or Annunciator 1AD-6 F/2, "NCP B PPER/LOWER OIL RESERVOIR LO LEVEL" Dark.

COMMENTS NOTE: KC flow is NOT required to the Thermal Barrier Hx whenever NC system temperature is less than 200°F.

STANDARD: Acknowledges note and continues.

COMMENTS JPM09 G

_SAT

_UNSAT SAT

_UNSAT SAT

_UNSAT Page 9 of 15 STEP 2.7 2.7.5 Verify the indicated #1 Seal Leakoff Flow (Step 2.7.3) is within the range of Revised Data Book Figure 26 as adjusted per Step 2.7.2.

STANDARD: Determines that the seal leakoff is within the normal range.

COMMENTS STEP 2.8:

Verify upper and lower oil pot levels normal, for the pump to be started, via one of the following:

Unit 1 Reactor Coolant Pump graphic (NCPMPALL)

OR Visual Inspection OR Associated annunciators DARK:

"NCP A UPPER/LOWER OIL RESERVOIR LO LEVEL" 1AD-6 F/2 STANDARD: Verifies upper and lower pot levels normal NCP GRAPHIC or Visual inspection (local) or Annunciator 1AD-6 F/2, "NCP B PPER/LOWER OIL RESERVOIR LO LEVEL" Dark.

COMMENTS NOTE: KC flow is NOT required to the Thermal Barrier Hx whenever NC system temperature is less than 200°F.

STANDARD: Acknowledges note and continues.

COMMENTS JPM09 G

_SAT

_UNSAT SAT

_UNSAT SAT UNSAT Page 9 of 15

STEP 2.9:

Verify KC flow to the Thermal Barrier Heater Exchanger normal, for the pump to be started,via one of the following:

SAT Unit 1 Reactor Coolant Pumps graphic (NCPMPALL)

OR Associated annunciators DARK:

UNSAT "NCP B THERMAL BARRIER KC OUTLET HIILO FLOW" 1AD-6 E/2 STANDARD: Verifies KC flow to Thermal Barrier Heat Exchanger: NC Pump GRAPHIC or Annunciator 1AD-6 E/2, "NCP B THERMAL BARRIER KC OUTLET HI/LO FLOW", Dark is normal.

COMMENTS STEP 2.10:

Verify KC flow to the Upper Motor Bearing Oil Cooler normal, for the pump to be started, via one of the following:

SAT Unit 1 Reactor Coolant Pumps graphic (NCPMPALL)

OR Associated annunciators DARK:

"NCP B MTR UPPER BRG KC OUTLET HI/LO FLOW"1AD-6 C/2 UNSAT STANDARD: Verifies KC flow to upper motor bearing oil cooler: NCP GRAPHIC or Annunciator 1AD-6 C/2 "NCP B MTR UPPER BRG KC OUTLET HIILO FLOW", Dark is normal.

COMMENTS JPM09 G Page 10 of 15 STEP 2.9:

Verify KC flow to the Thermal Barrier Heater Exchanger normal, for the pump to be started,via one of the following:

SAT Unit 1 Reactor Coolant Pumps graphic (NCPMPALL)

OR Associated annunciators DARK:

UNSAT "NCP B THERMAL BARRIER KC OUTLET HilLa FLOW" 1AD-6 E/2 STANDARD: Verifies KC flow to Thermal Barrier Heat Exchanger: NC Pump GRAPHIC or Annunciator 1AD-6 E/2, "NCP B THERMAL BARRIER KC OUTLET H lILa FLOW", Dark is normal.

COMMENTS STEP 2.10:

Verify KC flow to the Upper Motor Bearing Oil Cooler normal, for the pump to be started, via one of the following:

SAT Unit 1 Reactor Coolant Pumps graphic (NCPMPALL)

OR Associated annunciators DARK:

"NCP B MTR UPPER BRG KC OUTLET HilLa FLOW" 1AD-6 C/2 UNSAT STANDARD: Verifies KC flow to upper motor bearing oil cooler: NCP GRAPHIC or Annunciator 1AD-6 C/2 "NCP B MTR UPPER BRG KC OUTLET HilLa FLOW", Dark is normal.

COMMENTS JPM09 G Page 10 of 15

STEP 2.11:

Verify KC flow to the Lower Motor Bearing Oil Cooler normal, for the pump to be started, via one of the following:

Unit 1 Reactor Coolant Pumps graphic (NCPMPALL)

OR Associated annunciators DARK:

"NCP B MTR LOWER BRG KC OUTLET LO FLOW" 1 AD-6 D/2 STANDARD: Verifies KC flow to lower motor bearing oil cooler (NCP GRAPHIC or Annunciator 1AD-6 D/2 "NCP B MTR LOWER BRG KC OUTLET LO FLOW", Dark) is normal.

COMMENTS STEP 2.12:

Verify "230KV SWITCHYARD VOLTAGE LO" Annunciator on 1AD-11, Kl6 SAT UNSAT dark.

SAT STANDARD: Verifies Annunciator "230KV Swyd Volt Lo" on 1AD-11, Kl6 is dark.

COMMENTS STEP 2.13:

Two minutes prior to starting NC pump, start one oil lift pump for NCP to be started by pressing the "ON" pushbutton for:

"NC PUMP OIL LIFT PUMP B1" "NC PUMP OIL LIFT PUMP B2" STANDARD: Depresses RED "ON" pushbutton for NC PMP OIL LIFT PMP B1 or B2 approximately two minutes prior to starting 1 B NC Pump.

Verifies RED "ON" light lit.

COMMENTS JPM09 G

_UNSAT CRITICAL STEP SAT

_UNSAT Page 11 of 15 STEP 2.11:

Verify KC flow to the Lower Motor Bearing Oil Cooler normal, for the pump to be started, via one of the following:

Unit 1 Reactor Coolant Pumps graphic (NCPMPALL)

OR Associated annunciators DARK:

"NCP B MTR LOWER BRG KC OUTLET LO FLOW" 1 AD-6 D/2 STANDARD: Verifies KC flow to lower motor bearing oil cooler (NCP GRAPHIC or Annunciator 1AD-6 D/2 "NCP B MTR LOWER BRG KC OUTLET LO FLOW", Dark) is normal.

COMMENTS STEP 2.12:

Verify "230KV SWITCHYARD VOLTAGE LO" Annunciator on 1AD-11, Kl6 dark.

STANDARD: Verifies Annunciator "230KV Swyd Volt Lo" on 1AD-11, Kl6 is dark.

COMMENTS STEP 2.13:

Two minutes prior to starting NC pump, start one oil lift pump for NCP to be started by pressing the "ON" pushbutton for:

"NC PUMP OIL LIFT PUMP B1" "NC PUMP OIL LIFT PUMP B2" STANDARD: Depresses RED "ON" pushbutton for NC PMP OIL LIFT PMP B1 or B2 approximately two minutes prior to starting 1 B NC Pump.

Verifies RED "ON" light lit.

COMMENTS JPM09 G SAT

_UNSAT SAT UNSAT CRITICAL STEP SAT UNSAT Page 11 of 15

NOTE:

1. If NC pump is NOT started, the oil lift pump shall be secured to minimize stress on oil nozzles.

SAT

2. The Degraded Bus Voltage Relays (27N) may actuate on the essential bus being supplied by the 6.9KV Switchgear associated with the NC Pump to be started in the following step. The alarm condition is expected to clear within 36 seconds.{PIP 95-0287}

UNSAT STANDARD: Acknowledges note.

COMMENTS STEP 2.14:

CRITICAL Start desired NC pump by pressing the "ON" pushbutton for:

STEP "NC PMP 1B" STANDARD: Depress RED "ON" pushbutton for NC PMP 1 B. Verifies SAT RED "ON" light lit and pump amps stabilized near midscale on ammeter.

COMMENTS UNSAT JPM09 G Page 12 of 15 NOTE:

1. If NC pump is NOT started, the oil lift pump shall be secured to minimize stress on oil nozzles.

SAT

2. The Degraded Bus Voltage Relays (27N) may actuate on the essential bus being supplied by the 6.9KV Switchgear associated with the NC Pump to be started in the following step. The alarm condition is expected to clear within 36 seconds.{PIP 95-0287}

UNSAT STANDARD: Acknowledges note.

COMMENTS STEP 2.14:

CRITICAL Start desired NC pump by pressing the "ON" pushbutton for:

STEP "NC PMP 1B" STANDARD: Depress RED "ON" pushbutton for NC PMP 1 B. Verifies SAT RED "ON" light lit and pump amps stabilized near midscale on ammeter.

COMMENTS UNSAT JPM09 G Page 12 of 15

STEP 2.15:

Observe all pump and motor parameters to verify proper operation.

STANDARD: Verifies pump and motor parameters indicating proper operations:

a. #1 Seal DIP greater than or equal to 200 psid.
b. Inlet Seal Water Flow 7-10 gpm (may be greater than 10 due to pump start)
c. #1 Seal Leakoff Flow appropriate for current Delta P per Revised Data Book Figure 26.
d. Pump Radial Bearing Temp less than 225°F (1 MC5: 1 NVP5360 or NCP GRAPHIC).
e. #1 Seal Outlet Temp between 60°F & 235°F (1 MC5: 1 NVP5400 or NCP GRAPHIC).
f. Pump Shaft Vibration less than 15 mils. (NCP GRAPHIC or PANEL on rear of 1 MC-6).
g. Motor Bearings less than 190°F (NCP GRAPHIC).
h. Motor Winding Temp less than 302°F (NCP GRAPHIC).
i. Motor Frame Vibration less than 3 mils. (NCP GRAPHIC or PANEL on rear of 1 MC-6).

COMMENTS STEP 2.16:

Three minutes after flow in the affected NC loop exceeds 90%, stop the oil lift pump started in step 2.13.

STANDARD: Depress GREEN "OFF" pushbutton and verify GREEN "OFF" light lit for selected oil lift pump.

COMMENTS EXAMINER NOTE: Approximately 3 minutes after the pump is started, NCP vibration will increase to maximum in less than 15 seconds.

STANDARD: When student determines that trip criteria has been exceeded (30 mils below Mode 2), he will trip the 1 B NCP.

JPM09 G SAT UNSAT SAT UNSAT CRITICAL STEP SAT UNSAT Page 13 of 15 STEP 2.15:

Observe all pump and motor parameters to verify proper operation.

STANDARD: Verifies pump and motor parameters indicating proper operations:

a. #1 Seal DIP greater than or equal to 200 psid.
b. Inlet Seal Water Flow 7-10 gpm (may be greater than 10 due to pump start)
c. #1 Seal Leakoff Flow appropriate for current Delta P per Revised Data Book Figure 26.
d. Pump Radial Bearing Temp less than 225°F (1 MC5: 1 NVP5360 or NCP GRAPHIC).
e. #1 Seal Outlet Temp between 60°F & 235°F (1 MC5: 1 NVP5400 or NCP GRAPHIC).
f. Pump Shaft Vibration less than 15 mils. (NCP GRAPHIC or PANEL on rear of 1 MC-6).
g. Motor Bearings less than 190°F (NCP GRAPHIC).
h. Motor Winding Temp less than 302°F (NCP GRAPHIC).
i. Motor Frame Vibration less than 3 mils. (NCP GRAPHIC or PANEL on rear of 1 MC-6).

COMMENTS STEP 2.16:

Three minutes after flow in the affected NC loop exceeds 90%, stop the oil lift pump started in step 2.13.

STANDARD: Depress GREEN "OFF" pushbutton and verify GREEN "OFF" light lit for selected oil lift pump.

COMMENTS EXAMINER NOTE: Approximately 3 minutes after the pump is started, NCP vibration will increase to maximum in less than 15 seconds.

STANDARD: When student determines that trip criteria has been exceeded (30 mils below Mode 2), he will trip the 1 B NCP.

JPM09 G SAT UNSAT SAT UNSAT CRITICAL STEP SAT UNSAT Page 13 of 15

EXAMINER CUE: When pump is tripped, state: "The CRS has pulled AP/1/A15500/004 (Loss of Reactor Coolant Pump) and is ready to proceed."

SAT STANDARD: Determines that the task has been completed.

COMMENTS UNSAT This JPM is complete.

TIME STOP: __

JPM09 G Page 14 of 15 EXAMINER CUE: When pump is tripped, state: "The CRS has pulled AP/1/A15500/004 (Loss of Reactor Coolant Pump) and is ready to proceed."

SAT STANDARD: Determines that the task has been completed.

COMMENTS UNSAT This JPM is complete.

TIME STOP: __

JPM09 G Page 14 of 15

CANDIDATE CUE SHEET (TO BE RETURNED TO EXAMINER UPON COMPLETION OF TASK)

INITIAL CONDITIONS:

EP/1/A/SOOO/ES-O.2, Natural Circulation Cool down has been implemented following a Reactor Trip.

Control problems with 1 NV-309 require the valve be operated in manual.

INITIATING CUES:

Start NC Pump 1 B by completing OP/1/A/61S0/002A, NC Pump Operation Enclosure 4.1. The Initial Conditions of Enclosure 4.1 have been satisfied.

CANDIDATE CUE SHEET (TO BE RETURNED TO EXAMINER UPON COMPLETION OF TASK)

INITIAL CONDITIONS:

EP/1/A15000/ES-O.2, Natural Circulation Cooldown has been implemented following a Reactor Trip.

Control problems with 1 NV-309 require the valve be operated in manual.

INITIATING CUES:

Start NC Pump 1 B by completing OP/1/A161501002A, NC Pump Operation Enclosure 4.1. The Initial Conditions of Enclosure 4.1 have been satisfied.

.1 Startup and Operation of the NC Pumps

1. Initial Conditions 1.1 Review the Limits and Precautions.

OP/l/AJ6150/002 A Page 1 of7 1.2 Verify seal injection flow has been established to each Reactor Coolant Pump per OP/1/A/6200/001 (Chemical and Volume Control System).

1.3 Verify Component Cooling System is in Operation per OP/1/AJ6400/005 (Component Cooling System).

1.4 Verify Reactor Coolant Pumps are aligned per OP/1/AJ6150/002 B (NC Pump Motor Oil Fill and Drain System).

1.5 Verify Reactor Coolant System is filled per OP/1/AJ6150/001 (Filling and Venting The Reactor Coolant System).

1.6 Verify the NCDT is aligned for operation per OP/1/AJ65 00/0 14 (Operations Controlled Liquid Waste Systems).

1.7 IF NC Pump operation is expected to exceed one minute, verify NCP motor cooling water from YV (preferred) or RN has been established.

1.8 Ensure that a Written prejob briefing has been performed per Site Directive 3.0.21 (prejob Briefing) that includes a discussion of reactivity management concerns with this procedure..1 Startup and Operation of the NC Pumps

1. Initial Conditions 1.1 Review the Limits and Precautions.

OP!lIAl61501002 A Page 1 of7 1.2 Verify seal injection flow has been established to each Reactor Coolant Pump per OP/1/A/62001001 (Chemical and Volume Control System).

1.3 Verify Component Cooling System is in Operation per OP/1/Al64001005 (Component Cooling System).

1.4 Verify Reactor Coolant Pumps are aligned per OP/1/ Al6150/002 B (NC Pump Motor Oil Fill and Drain System).

1.5 Verify Reactor Coolant System is filled per OP/1/ Al6150/00 1 (Filling and Venting The Reactor Coolant System).

1.6 Verify the NCDT is aligned for operation per OP/1/Al6500/o14 (Operations Controlled Liquid Waste Systems).

1.7 IF NC Pump operation is expected to exceed one minute, verify NCP motor cooling water from YV (preferred) or RN has been established.

1.8 Ensure that a Written prejob briefing has been performed per Site Directive 3.0.21 (Prejob Briefing) that includes a discussion of reactivity management concerns with this procedure.

.1 Startup and Operation of the NC Pumps OP/I/A/6 I 501002 A Page 2 of7

2. Procedure CAUTION: An NC Pump shall NOT be started if associated 6.9 KV switchgear is supplying essential switchgear lETA or lETB and switchyard voltage is less than or equal to 223 KV or only one off-site source of power is available.

NOTE:

I. In order to start an NC Pump, the underfrequency condition must be cleared by having at least three of four 6900V breakers (I TA, B, C, D-3) racked in and energized.

2. NC Pump operational configuration restrictions, as follows, will ensure adequate PZR spray for press control, maintain spray line water solid, and prevent thermal stratification of spray line {PIP C-00-04752}:

For single pump operation, ensure NC Pump B is in service, For multiple pump operation, ifNC Pump B is NOT in service, NC Pumps A, C and D will need to be in service, {PIP C-01-4130}

otherwise, Auxiliary PZR spray flow will have to be used.

2.1 IF Unit I is in Mode 5, refer to Tech Spec Table 3.4.12-1 (Reactor Coolant Pump Operating Restrictions For Low Temperature Overpressure Protection) for temperature limitations on NC Pump starts.

2.2 IF the pump to be started will be the fourth NC Pump in service on Unit I, verity NC temperature is ~ 130°F. {PIP 96-1290, PIP 02-484}

NOTE:

If#1 Seal8P gauge overranged, 8P can be determined using INVI25B (Excess Letdn Hx Otlt Ctrl) "VCT" or "NCDT" switch position as follows:

"VCT" position: NC Press minus Excess Letdn Hx Odt Press = #1 Seal8P "NCDT" position: NC Press minus VCT Press = #1 Seal M 2.3 Verity that No. I seal M is greater than 200 psig for the pump to be started per the following gauges: (Control Board IMC5)

D IA NCP: INVP5230 D IB NCP: INVP5220 D IC NCP: INVP5210 D ID NCP: INVP5200.1 Startup and Operation of the NC Pumps OP/l!A161501002 A Page 2 of7

2. Procedure CAUTION:

An NC Pump shall NOT be started if associated 6.9 KV switchgear is supplying essential switchgear lETA or 1ETB and switchyard voltage is less than or equal to 223 KV or only one off-site source of power is available NOTE:

1. In order to start an NC Pump, the underfrequency condition must be cleared by having at least three of four 6900V breakers (1 TA, B, C, D-3) racked in and energized.
2. NC Pump operational configuration restrictions, as follows, will ensure adequate PZR spray for press control, maintain spray line water solid, and prevent thermal stratification of spray line {PIP C-00-04 752}:

For single pump operation, ensure NC Pump B is in service, For multiple pump operation, ifNC Pump B is NOT in service, NC Pumps A, C and D will need to be in service, {PIP C-01-4130}

otherwise, Auxiliary PZR spray flow will have to be used.

2.1 IF Unit 1 is in Mode 5, refer to Tech Spec Table 3.4.12-1 (Reactor Coolant Pump Operating Restrictions For Low Temperature Overpressure Protection) for temperature limitations on NC Pump starts.

2.2 IF the pump to be started will be the fourth NC Pump in service on Unit 1, verifyNC temperature is::::: 130°F. {PIP 96-1290, PIP 02-484}

NOTE:

1f#1 Seal ~P gauge overranged, ~P can be determined using 1NV125B (Excess Letdn Hx Otlt Ctrl) "VCT" or "NCDT" switch position as follows:

"VCT" position: NC Press minus Excess Letdn Hx Otlt Press = #1 Seal ~P "NCDT" position: NC Press minus VCT Press = #1 Seal M 2.3 Verify that No.1 seal M is greater than 200 psig for the pump to be started per the following gauges: (Control Board 1MC5) o 1A NCP: 1NVP5230 o 1B NCP: 1NVP5220 o 1C NCP: 1NVP5210 o 1D NCP: 1NVP5200

.1 Startup and Operation of the NC Pumps OP/l!Al6 1 501002 A Page 3 of7 2.4 Verify that the standpipe level for the pump to be started is normal by its associated annunciator DARK:

D "NCP A #2 SEAL S-PIPE HIILO LVL" lAD-7 All D "NCP B #2 SEAL S-PIPE HIILO L VL" lAD-7 A/2 D "NCP C #2 SEAL S-PIPE HIILO LVL" lAD-7 Al3 D "NCP D #2 SEAL S-PIPE HIILO LVL" lAD-7 A/4 2.5 Verify that VCT pressure is ~ 15 psig.

2.6 Verify 7-10 gpm seal injection flow on the pump to be started by the following gauges:

(Control Board lMC5)

D lA NCP: lNVP5330 D lB NCP: lNVP5320 D lC NCP: lNVP5310 D lD NCP: lNVP5300.1 Startup and Operation of the NC Pumps OP/l!Al61501002 A Page 3 of7 2.4 VerifY that the standpipe level for the pump to be started is nonnal by its associated annunciator DARK:

o "NCP A #2 SEAL S-PIPE HI/LO LVL" lAD-7 All o "NCP B #2 SEAL S-PIPE HIILO LVL" lAD-7 A/2 o "NCP C #2 SEAL S-PIPE HI/LO LVL" lAD-7 Al3 o "NCP D #2 SEAL S-PIPE HIILO L VL" lAD-7 A/4 2.5 VerifY that VCT pressure is ~ 15 psig.

2.6 VerifY 7-10 gpm seal injection flow on the pump to be started by the following gauges:

(Control Board lMC5) o lA NCP: lNVP5330 o lB NCP: lNVP5320 o lC NCP: lNVP53l0 o lD NCP: lNVP5300

.1 Startup and Operation of the NC Pumps OP/l!A/6150/002 A Page 4 of7 NOTE:

1. 1f#1 Seal LeakoffFlow rate is < 1.0 gpm, the # 1 Seal Low Flow indication shall be used.
2. 1f#1 Seal ~P gauge overranged, ~P can be determined using INV125B (Excess Letdn Hx Otlt Ctrl) "VCT" or "NCDT" switch position as follows:

"VCT" position: NC Press minus Excess Letdn Hx Otlt Press = #1 Seal ~P "NCDT" position: NC Press minus VCT Press = #1 Seal ~P 2.7 Verify adequate #1 Seal LeakoffFlow on the pump to be started as follows:

2.7.1 Determine required #1 Seal LeakoffFlow from Revised Data Book Figure 26 (NC Pump No.1 Seal Normal Operating Range).

2.7.2 Add 0.26 gpm to the minimum required #1 Seal LeakoffFlow of Figure 26 to correct for an expected drop in leakoffflow on pump start (0.20 gpm) and instrument inaccuracy (0.06 gpm).

2.7.3 Obtain the current #1 Seal LeakoffFlow per one of the following:

o DCS graphic 6002 (NC PUMPS)

OR o Unit 1 Reactor Coolant Pumps graphic (NCPMPALL)

OR o 1 NVCR5 140 (NC Pump Lo LeakoffFlow) (lMC5)

OR o INVCR5121 (NC Pump Hi LeakoffFlow) (IMC5)

OR Appropriate OAC point o

CIA1370 (NC Pmp A No.1 Seal LeakoffLo Flow) o CIA0436 (NC Pmp A No.1 Seal LeakoffFlow) o CIA1376 (NC Pmp B No.1 Seal LeakoffLo Flow) o CIA0442 (NC Pmp B No.1 Seal LeakoffFlow) o CIA1382 (NC Pmp C No.1 Seal LeakoffLo Flow) o CIA0448 (NC Pmp C No.1 Seal LeakoffFlow) o CIA1388 (NC Pmp D No.1 Seal LeakoffLo Flow) o CIA0454 (NC Pmp D No.1 Seal LeakoffFlow) 2.7.4 IF the current #1 Seal LeakoffFlow (Step 2.7.3) is less than the minimum flow determined in Step 2.7.2, refer to Enclosure 4.4 (Operator Action For Low #1 Seal LeakoffFlow).

2.7.5 Verify the indicated # 1 Seal Leakoff Flow (Step 2.7.3) is within the range of Revised Data Book Figure 26 as adjusted per Step 2.7.2..1 Startup and Operation of the NC Pumps OP/l!A/6150/002 A Page 4 of7 NOTE:

1. If#1 Seal LeakoffFlow rate is < 1.0 gpm, the # 1 Seal Low Flow indication shall be used.
2. If#1 Seal ~P gauge overranged, ~P can be determined using INV125B (Excess Letdn Hx Otlt Ctrl) "VCT" or "NCDT" switch position as follows:

"VCT" position: NC Press minus Excess Letdn Hx Otlt Press = # 1 Seal ~P "NCDT" position: NC Press minus VCT Press = #1 Seal ~P 2.7 Verify adequate #1 Seal LeakoffFlow on the pump to be started as follows:

2.7.1 Determine required #1 Seal LeakoffF10w from Revised Data Book Figure 26 (NC Pump No.1 Seal Normal Operating Range).

2.7.2 Add 0.26 gpm to the minimum required #1 Seal LeakoffFlow of Figure 26 to correct for an expected drop in leakoffflow on pump start (0.20 gpm) and instrument inaccuracy (0.06 gpm).

2.7.3 Obtain the current #1 Seal LeakoffF10w per one of the following:

D DCS graphic 6002 (NC PUMPS)

OR D Unit 1 Reactor Coolant Pumps graphic (NCPMPALL)

OR D 1NVCR5140 (NC Pump Lo LeakoffFlow) (lMC5)

OR D 1NVCR5121 (NC Pump Hi LeakoffFlow) (lMC5)

OR Appropriate OAC point D

C1A1370 (NC Pmp A No.1 Seal LeakoffLo Flow)

D C1A0436 (NC Pmp A No.1 Seal LeakoffFlow)

D C1A1376 (NC Pmp B No.1 Seal LeakoffLo Flow)

D C1A0442 (NC Pmp B No.1 Seal LeakoffFlow)

D C1A1382 (NC Pmp C No.1 Seal LeakoffLo Flow)

D CIA0448 (NC Pmp C No.1 Seal LeakoffF10w)

D C1A1388 (NC Pmp D No.1 Seal LeakoffLo Flow)

D C1A0454 (NC Pmp D No.1 Seal LeakoffFlow) 2.7.4 IF the current #1 Seal LeakoffF10w (Step 2.7.3) is less than the minimum flow determined in Step 2.7.2, refer to Enclosure 4.4 (Operator Action For Low #1 Seal LeakoffF10w).

2.7.5 Verify the indicated #1 Seal LeakoffFlow (Step 2.7.3) is within the range of Revised Data Book Figure 26 as adjusted per Step 2.7.2.

.1 Startup and Operation of the NC Pumps OPIl!Al61501002 A Page 5 of7 2.8 VerifY upper and lower oil pot levels normal, for the pump to be started, via one of the following:

o Unit 1 Reactor Coolant Pumps graphic (NCPMP ALL)

OR o Visual inspection (local)

OR

o "NCP A UPPERILOWER OIL RESERVOIR LO LEVEL" 1AD-6 FI1 o "NCP B UPPERILOWER OIL RESERVOIR LO LEVEL" 1AD-6 F12 o NCP C UPPERILOWER OIL RESERVOIR LO LEVEL" 1AD-6 F/3 o "NCP D UPPER/LOWER OIL RESERVOIR LO LEVEL" 1AD-6 F/4 NOTE:

KC flow is NOT required to the Thermal Barrier Hx whenever NC System temperature is less than 200°F.

2.9 VerifY KC flow to the Thermal Barrier Heater Exchanger normal, for the pump to be started, via one of the following:

o Unit 1 Reactor Coolant Pumps graphic (NCPMPALL)

OR

o "NCP A THERMAL BARRIER KC OUTLET HIILO FLOW" 1AD-6 Ell o

"NCP B THERMAL BARRIER KC OUTLET HIlLO FLOW" 1AD-6 E/2 o

"NCP C THERMAL BARRIER KC OUTLET HIILO FLOW" lAD-6 E/3 o

"NCP D THERMAL BARRIER KC OUTLET HIILO FLOW" 1AD-6 E/4 2.10 VerifY KC flow to the Upper Motor Bearing Oil Cooler normal, for the pump to be started, via one of the following:

o Unit 1 Reactor Coolant Pumps graphic (NCPMPALL)

OR

o "NCP A MTR UPPER BRG KC OUTLET HIILO FLOW" lAD-6 C/1 o

"NCP B MTR UPPER BRG KC OUTLET HIILO FLOW" 1AD-6 C/2 o

"NCP C MTR UPPER BRG KC OUTLET HIILO FLOW" lAD-6 C/3 o

"NCP D MTR UPPER BRG KC OUTLET HIILO FLOW" 1AD-6 C/4.1 Startup and Operation of the NC Pumps OP;1/A/6150/002 A Page 5 of7 2.8 Verify upper and lower oil pot levels normal, for the pump to be started, via one of the following:

o Unit 1 Reactor Coolant Pumps graphic (NCPMPALL)

OR o Visual inspection (local)

OR

o "NCP A UPPERILOWER OIL RESERVOIR LO LEVEL" lAD-6 F/l o "NCP B UPPER/LOWER OIL RESERVOIR LO LEVEL" lAD-6 F/2 o "NCP C UPPERILOWER OIL RESERVOIR LO LEVEL" lAD-6 F/3 o "NCP D UPPER/LOWER OIL RESERVOIR LO LEVEL" lAD-6 F/4 NOTE:

KC flow is NOT required to the Thermal Barrier Hx whenever NC System temperature is less than 200°F.

2.9 Verify KC flow to the Thermal Barrier Heater Exchanger normal, for the pump to be started, via one of the following:

o Unit 1 Reactor Coolant Pumps graphic (NCPMPALL)

OR

o "NCP A THERMAL BARRIER KC OUTLET HIILO FLOW" lAD-6 Ell o

"NCP B THERMAL BARRIER KC OUTLET HIILO FLOW" lAD-6 E/2 o

"NCP C THERMAL BARRIER KC OUTLET HIILO FLOW" lAD-6 E/3 o

"NCP D THERMAL BARRIER KC OUTLET HIILO FLOW" lAD-6 E/4 2.10 Verify KC flow to the Upper Motor Bearing Oil Cooler normal, for the pump to be started, via one of the following:

o Unit 1 Reactor Coolant Pumps graphic (NCPMPALL)

OR

o "NCP A MTR UPPER BRG KC OUTLET HIILO FLOW" lAD-6 CII o

"NCP B MTR UPPER BRG KC OUTLET HIILO FLOW" lAD-6 C/2 o

"NCP C MTR UPPER BRG KC OUTLET HIILO FLOW" lAD-6 C/3 o

"NCP D MTR UPPER BRG KC OUTLET HIILO FLOW" lAD-6 C/4

.1 Startup and Operation of the NC Pumps OP!l/A/61501002 A Page 6 of7 2.11 Verify KC flow to the Lower Motor Bearing Oil Cooler normal, for the pump to be started, via one of the following:

o Unit 1 Reactor Coolant Pumps graphic (NCPMPALL)

OR

o "NCP A MTR LOWER BRG KC OUTLET LO FLOW" 1AD-6 Dil o

"NCP B MTR LOWER BRG KC OUTLET LO FLOW" 1AD-6 D/2 o

"NCP C MTR LOWER BRG KC OUTLET LO FLOW" 1AD-6 D/3 o

"NCP D MTR LOWER BRG KC OUTLET LO FLOW" IAD-6 D/4 2.12 Verify annunciator 1AD-ll, K-6, "230 KV SWITCHYARD VOLTAGE LO" is dark.

2.13 Two minutes prior to starting N C pump, start one oil lift pump for N CP to be started by pressing the "ON" pushbutton for:

o "NC PUMP OIL LIFT PUMP AI" o "NC PUMP OIL LIFT PUMP A2" o "NC PUMP OIL LIFT PUMP B1" o "NC PUMP OIL LIFT PUMP B2" o "NC PUMP OIL LIFT PUMP C1" o "NC PUMP OIL LIFT PUMP C2" o "NC PUMP OIL LIFT PUMP D1" o "NC PUMP OIL LIFT PUMP D2" NOTE:

1. IfNC pump is NOT started, the oil lift pump shall be secured to minimize stress on oil nozzles.
2. The Degraded Bus Voltage Relays (27N) may actuate on the essential bus being supplied by the 6.9KV Switchgear associated with the NC Pump to be started in the following step. The alarm condition is expected to clear within 36 seconds. {PIP 95-0287}

2.14 Start desired NC pump by pressing the "ON" pushbutton for: (R.M.)

o "NC PUMP 1A" o "NC PUMP 1B" o "NCPUMP 1C" o "NC PUMP 1D".1 Startup and Operation of the NC Pumps OP!lIA/61501002 A Page 60f7 2.11 Verify KC flow to the Lower Motor Bearing Oil Cooler nonnal, for the pump to be started, via one of the following:

D Unit 1 Reactor Coolant Pumps graphic (NCPMPALL)

OR

D "NCP A MTR LOWER BRG KC OUTLET LO FLOW" 1AD-6 DIl D

"NCP B MTR LOWER BRG KC OUTLET LO FLOW" 1AD-6 D/2 D

"NCP C MTR LOWER BRG KC OUTLET LO FLOW" 1AD-6 D/3 D

"NCP D MTR LOWER BRG KC OUTLET LO FLOW" lAD-6 D/4 2.12 Verify annunciator 1AD-ll, K-6, "230 KV SWITCHYARD VOLTAGE LO" is dark.

2.13 Two minutes prior to starting NC pump, start one oil lift pump for NCP to be started by pressing the "ON" pushbutton for:

D "NC PUMP OIL LIFT PUMP AI" D "NC PUMP OIL LIFT PUMP A2" D "NC PUMP OIL LIFT PUMP B 1" D "NC PUMP OIL LIFT PUMP B2" D "NC PUMP OIL LIFT PUMP C1" D "NC PUMP OIL LIFT PUMP C2" D "NC PUMP OIL LIFT PUMP D1" D "NC PUMP OIL LIFT PUMP D2" NOTE:

1. IfNC pump is NOT started, the oil lift pump shall be secured to minimize stress on oil nozzles.
2. The Degraded Bus Voltage Relays (27N) may actuate on the essential bus being supplied by the 6.9KV Switchgear associated with the NC Pump to be started in the following step. The alann condition is expected to clear within 36 seconds. {PIP 95-0287}

2.14 Start desired NC pump by pressing the "ON" pushbutton for: (R.M.)

D "NC PUMP lA" D "NC PUMP 1B" D "NC PUMP 1 CIt D "NC PUMP lD"

.1 Startup and Operation of the NC Pumps OP/I/A/61501002 A Page 7 of7 2.15 Observe all pump and motor parameters to verify proper operation.

NOTE:

If#1 Seal ~P gauge overranged, ~

can be determined using INV12SB (Excess Letdn Hx Otlt Ctrl) "VCT" or "NCDT" switch position as follows:

"VCT" position: NC Press minus Excess Letdn Hx Odt Press = #1 Seal ~P "NCDT" position: NC Press minus VCT Press = #1 Seal ~P

  1. 1 Seal ~

2: 200#.

Inlet Seal Water Flow 7 gpm to 10 gpm.

NOTE:

If#1 Seal LeakoffFlow Rate is < 1.0 gpm, the #1 Seal Low Flow indication shall be used.

The 0.26 gpm flow correction for the required flow rate per Step 2.7.2 of Enclosure 4.1 (Startup and Operation of the NC Pumps), shall be reduced to 0.06 gpm (instrument accuracy).

  1. 1 Seal LeakoffFlow per Step 2.7.

Pump Radial Bearing Temp. < 225°F.

No.1 Seal Outlet temp. between 60°F and 235°F.

Pump shaft vibration < 15 mils.

Motor bearings < 190°F.

Motor winding temp. < 302°F.

Motor frame vibration < 3 mils.

2.16 Three minutes after flow in the affected NC Loop exceeds 90%, stop the oil lift pump started in Step 2.13.

2.17 Repeat Steps 2.1 through 2.16 of this enclosure for starting additional NC pumps.

2.18 Do NOT file this enclosure in the Control Copy folder of this procedure..1 Startup and Operation of the NC Pumps OP!l/A/6150/o02 A Page 7 of7 2.15 Observe all pump and motor parameters to verify proper operation.

NOTE:

If#1 Seal ~P gauge overranged, ~P can be determined using INV125B (Excess Letdn Hx Otlt Ctrl) "VCT" or "NCDT" switch position as follows:

"VCT" position: NC Press minus Excess Letdn Hx Otlt Press = #1 Seal ~P "NCDT" position: NC Press minus VCT Press = #1 Seal ~P

  1. 1 Seal M ;::: 200#.

Inlet Seal Water Flow 7 gpm to 10 gpm.

NOTE:

If#1 Seal LeakoffFlow Rate is < 1.0 gpm, the #1 Seal Low Flow indication shall be used.

The 0.26 gpm flow correction for the required flow rate per Step 2.7.2 of Enclosure 4.1 (Startup and Operation of the NC Pumps), shall be reduced to 0.06 gpm (instrument accuracy).

  1. 1 Seal LeakoffFlow per Step 2.7.

Pump Radial Bearing Temp. < 225°F.

No.1 Seal Outlet temp. between 60°F and 235°F.

Pump shaft vibration < 15 mils.

Motor bearings < 190°F.

Motor winding temp. < 302°F.

Motor frame vibration < 3 mils.

2.16 Three minutes after flow in the affected NC Loop exceeds 90%, stop the oil lift pump started in Step 2.13.

2.17 Repeat Steps 2.1 through 2.16 of this enclosure for starting additional NC pumps.

2.18 Do NOT file this enclosure in the Control Copy folder ofthis procedure.

DUKE POWER CATAWBA OPERATIONS TRAINING Prepared By:

Reviewed By:

OPS Review:

Approved By:

Start Reactor Coolant Pump 1 B JOB PERFORMANCE MEASURE

© 1995 Duke Power Each individual JPM packet has been reviewed to contain the following:

Complete JPM - all pages Complete and appropriate procedurelreference document as specified in JPM initial conditions One page (examinee's copy) of JPM initial conditions

~~~

=~~~~~~~--~~~~~--~I Prior to JPM session, ensure simulator IC snap that establishes initial conditions for the JPM is accurate and complete Prior to each JPM, ensure simulator setup for the performance of the JPM is verified as accurate as follows:

Appropriate IC selected Test area ready for conduct of JPM R. J. Katalinich Date:

10/2/00 R. W. Smith Date:

10/3/00 N/A Date D. P. Mc Intosh Date:

10/4/00 OP-CN-PS-NCP-OB1 FOR TRAINING PURPOSES ONL Y Page 10'B REV. 12 DUKE POWER CATAWBA OPERATIONS TRAINING Prepared By:

Reviewed By:

OPS Review:

Approved By:

Start Reactor Coolant Pump 1 B JOB PERFORMANCE MEASURE

© 1995 Duke Power JPM Selection Check

. (complete.

to copying)

JPM is current with latest procedure/reference document revision (all JPMs)

JPM setup on simulator is current with the simulator training disk to be used (MALF, GCF, LOA, OVR) (N/A if plant JPM)

'JPM*

(All JPMs)

(c()mplet~ after copying)

Each individual JPM packet has been reviewed to contain the following:

Complete JPM - all pages Complete and appropriate procedure/reference document as specified in JPM initial conditions One page (examinee's copy) of JPM initial conditions (N/Aif plal1tJPM)

Prior to JPM session, ensure simulator IC snap that establishes initial conditions for the JPM is accurate and complete Prior to each JPM, ensure simulator setup for the performance of the JPM is verified as accurate as follows:

Appropriate IC selected Test area ready for conduct of JPM R. J. Katalinich Date:

10/2/00 R. W. Smith Date:

10/3/00 N/A Date D. P. Mc Intosh Date:

10/4/00 OP-CN-PS-NCP-OB1 FOR TRAINING PURPOSES ONL Y Page 10'B REV. 12

DUKE POWER CATAWBA OPERATIONS TRAINING Start Reactor Coolant Pump 1 B Examinee: ---------------------------------------------

RO/SRO Y

10 N

STANDARD:

Seal injection flow to 1 B NCP is restored to 7-10 gpm and 1 B reactor coolant pump is successfully started.

REFERENCES:

OP/1/N61501002A (Reactor Coolant Pump) Encl. 4.1 INITIATING CUE:

EP/1/N5000/ES-O.2, Natural Circulation Cooldown has been implemented following a Reactor Trip. Control problems with 1 NV-309 require the valve be operated in manual. The SRO instructs you to attempt to start NC Pump 1B by completing OP/1/N61501002A, NC Pump Operation Encl.

4.1. The Initial Conditions of Encl. 4.1 have been satisfied.

SATISFACTORY UNSATISFACTORY EXAMINER SIGNATURE: ____________

DATE:

EXAMINER (print):

OP-CN-PS-NCP-OB1 FOR TRAINING PURPOSES ONL Y Page 2 ofB REV. 12 DUKE POWER CATAWBA OPERATIONS TRAINING Start Reactor Coolant Pump 1 B Examinee: _____________________ _

IV POSITION ROISRO STANDARD:

SYSTEM NCP FAULTEd*

('(!t-J)

Y

....*... TESTING ENVIRONMENT SIMULATOR VALIDATED TIME 10 KIA #

003 000 GEN 13 (3.6/3.7)

TlfIIIl:::CRITICAL (YIN)

N Seal injection flow to 1 B NCP is restored to 7-10 gpm and 1 B reactor coolant pump is successfully started.

REFERENCES:

OP/1/A/61S01002A (Reactor Coolant Pump) Encl. 4.1 INITIATING CUE:

EP/1IA/SOOO/ES-O.2, Natural Circulation Cooldown has been implemented following a Reactor Trip. Control problems with 1 NV-309 require the valve be operated in manual. The SRO instructs you to attempt to start NC Pump 1 B by completing OP/1/A/61S01002A, NC Pump Operation Encl.

4.1. The Initial Conditions of Encl. 4.1 have been satisfied.

SiARTTIME i'

END TIME DURATION (minutes)

OP~RATOR PERFORMANCEAS EVALUATED TO STANOA(tD (circ(eone)

~..'

c SATISFACTORY UNSATISFACTORY EXAMINER SIGNATURE: ____________

DATE:

EXAMINER (print):

OP-CN-PS-NCP-OB1 FOR TRAINING PURPOSES ONL Y Page 2 ofB REV. 12

DUKE POWER CATAWBA OPERATIONS TRAINING SIMULATOR SETUP SHEET

1. Reset to any "at power" SNAP.
2. Manually trip the reactor at 1 MC-1.
3. Trip all (4) four NCP breakers at 1MC-10.
4. Reset CA and control flow to maintain S/G levels at 38% N/R level.
5. Place 1 NV-309 in manual and reduce total seal water flow to.... 12 gpm.
6. Freeze the simulator and write to SNAP.

IC SELECTED _____

OP-CN-PS-NCP-OB1 FOR TRAINING PURPOSES ONL Y Page30fB REV. 12 DUKE POWER CATAWBA OPERATIONS TRAINING SIMULATOR SETUP SHEET

1. Reset to any "at power" SNAP.
2. Manually trip the reactor at 1 MC-1.
3. Trip all (4) four NCP breakers at 1MC-10.
4. Reset CA and control flow to maintain S/G levels at 38% N/R level.
5. Place 1 NV-309 in manual and reduce total seal water flow to - 12 gpm.
6. Freeze the simulator and write to SNAP.

IC SELECTED _____

OP-CN-PS-NCP-OB1 FOR TRAINING PURPOSES ONL Y Page 3 ofB REV. 12

1.
2.
3.
4.
5.
6.
7.

DUKE POWER Caution and Note prior to Step 2.1 If Unit 1 is in Mode 5, refer to Tech Spec Table 3.4.12-1 (NC Pump Operational Restriction for low temperature overpressure protection).

If the pump to be started will be the fourth NC pump in service on Unit 1, perform the following:

Verify No.1 Seal DIP is greater than 200 psig for the pump to be started per the following gauges: (Control Board MC-5) 1 B NCP: 1 NVP 5220 Verify that the standpipe level for the pump to be started is normal by its associated annunciator DARK.

"NCP B #2 SEAL S-PIP HIILO LVL" 1AD-7 Al2 Verify VCT pressure is equal to or greater than 15 psig.

Verify 7-10 gpm seal injection flow on the pump to be started by the following gauges:

(Control Board MC-5) 1 B NCP: 1 NCP5320 CATAWBA OPERATIONS TRAINING Operator determines that the offsite power is correctly aligned for NCP 1 B start and the Underfrequency condition does not exist.

Per Initiating cue the reactor should be determined to not be in Mode 5.

Per the initiating cue this is the first pump to be started. Examinee should go on to step 2.3.

Verifies DIP indication (1 MC5: 1 NVP5220) for 1 B NC Pump is greater than 200 psig.

Verifies 1AD-7 Al2 "NCP B #2 SEAL S-PIPE HIILO LVL" alarm is dark.

Verifies VCT pressure (1 MC5: 1 NVP5500 or NV GRAPHIC) is greater than 15 psig.

Observes seal injection flow (1 NVP5320 on 1 MC-5) is approximately 4-5 gpm.

OP-CN-PS-NCP-OB1 FOR TRAINING PURPOSES ONL Y Page 4 of8 REV. 12 DUKE POWER CATAWBA OPERATIONS TRAINING

  • indicates,a "critical" step H, '
1.
2.
3.
4.
5.
6.
7.

STEP STANDARD

'<'_','i Caution and Note prior to Step 2.1 Operator determines that the offsite power is correctly aligned for NCP 1 B start and the Underfrequency condition does not exist.

If Unit 1 is in Mode 5, refer to Tech Spec Per Initiating cue the reactor should be Table 3.4.12-1 (NC Pump Operational determined to not be in Mode 5.

Restriction for low temperature overpressure protection).

If the pump to be started will be the fourth Per the initiating cue this is the first pump to NC pump in service on Unit 1, perform the be started. Examinee should go on to step following:

2.3.

Verify No.1 Seal DIP is greater than 200 Verifies DIP indication (1 MC5: 1 NVP5220) psig for the pump to be started per the for 1 B NC Pump is greater than 200 psig.

following gauges: (Control Board MC-5) 1 B NCP: 1 NVP 5220 Verify that the standpipe level for the pump Verifies 1AD-7 A12 "NCP B #2 SEAL S-PIPE to be started is normal by its associated HIILO LVL" alarm is dark.

annunciator DARK.

"NCP B #2 SEAL S-PIP HIILO LVL" 1AD-7 A12 Verify VCT pressure is equal to or greater Verifies VCT pressure (1 MC5: 1 NVP5500 or than 15 psig.

NV GRAPHIC) is greater than 15 psig.

Verify 7-10 gpm seal injection flow on the Observes seal injection flow (1 NVP5320 on pump to be started by the following gauges:

1 MC-5) is approximately 4-5 gpm.

(Control Board MC-5) 1 B NCP: 1 NCP5320 OP-CN-PS-NCP-OB1 FOR TRAINING PURPOSES ONL Y Page 4 ofB REV. 12 S/U

  • 7.
8.
9.
10.

DUKE POWER Response to low seal injection flow.

Verify adequate No. 1 Seal leakoff flow on the pump to be started.

Verify upper and lower oil pot levels normal, for the pump to be started.

Verify KC flow to Thermal Barrier Heat Exchanger normal, for the pump to be started.

CATAWBA OPERATIONS TRAINING Either:

1.

Manually adjust 1 NV-309 to restore seal injection flow OR

2.

Inform Supervisor of problem.

If Supervisor informed:

CUE: Inform examinee to restore seal injection flow to its required value.

NOTE: Examinee should manually adjust 1 NV-309.

Verifies #1 seal leakoff flow:

a. Determines required #1 Seal Leakoff Flow from Revised Data Book Figure 26.
b. Adds 0.26 gpm to the minimum required
  1. 1 Seal Leakoff flow of Figure 26
c. Verify the indicated #1 Seal Leakoff flow is within the range of Data Book Figure 26 as adjusted per step 2.7.2 per one of the following: OAC computer point C1A1376, or C1A0442, Chart recorders 1 NVCR-5140 or 1 NVCR-5121, or Computer NCP Graphic Verifies upper and lower pot levels normal NCP GRAPHIC or Visual inspection (local) or Annunciator 1AD-6 F/2, "NCP B UPPER/LOWER OIL RESERVOIR LO LEVEL" Dark.

Verifies KC flow to Thermal Barrier Heat Exchanger: NC Pump GRAPHIC or Annunciator 1AD-6 E/2, "NCP B THERMAL BARRIER KC OUTLET HI/LO FLOW", Dark is normal.

OP-CN-PS-NCP-OB1 FOR TRAINING PURPOSES ONL Y Page 5 o'B REV. 12 DUKE POWER CATAWBA OPERATIONS TRAINING

  • indicatesc:i:'"critical" ~tep/.

...'\\

  • 7.
8.
9.
10.

STEP Response to low seal injection flow.

Verify adequate No.1 Sealleakoff flow on the pump to be started.

Verify upper and lower oil pot levels normal, for the pump to be started.

Verify KC flow to Thermal Barrier Heat Exchanger normal, for the pump to be started.

STANDARD Either:

1.

Manually adjust 1 NV-309 to restore seal injection flow OR

2.

Inform Supervisor of problem.

If Supervisor informed:

CUE: Inform examinee to restore seal injection flow to its required value.

NOTE: Examinee should manually adjust 1 NV-309.

Verifies #1 seal leakoff flow:

a. Determines required #1 Seal Leakoff Flow from Revised Data Book Figure 26.
b. Adds 0.26 gpm to the minimum required
  1. 1 Seal Leakoff flow of Figure 26
c. Verify the indicated #1 Seal Leakoff flow is within the range of Data Book Figure 26 as adjusted per step 2.7.2 per one of the following: OAC computer point C1A1376, or C1A0442, Chart recorders 1 NVCR-5140 or 1 NVCR-5121, or Computer NCP Graphic Verifies upper and lower pot levels normal NCP GRAPHIC or Visual inspection (local) or Annunciator 1AD-6 F/2, "NCP B UPPER/LOWER OIL RESERVOIR LO LEVEL" Dark.

Verifies KC flow to Thermal Barrier Heat Exchanger: NC Pump GRAPHIC or Annunciator 1AD-6 El2, "NCP B THERMAL BARRIER KC OUTLET HIILO FLOW", Dark is normal.

OP-CN-PS-NCP-OB1 FOR TRAINING PURPOSES ONL Y Page 5 o'B REV. 12 S/U

11.
12.
13.
  • 14.

DUKE POWER Verify KC flow to Upper Motor Brg. Oil Cooler normal, for the pump to be started.

Verify KC flow to Lower Motor Brg. Oil Cooler normal, for the pump to be started.

Verify "230KV Swyd Volt Lo" Annunciator on 1 AD-11, Kl6 dark.

Two minutes prior to starting NC pump, start one oil lift pump for NCP to be started.

  • 15.

Start desired NC pump by pressing the "ON" pushbutton for:

"NC PMP 1B" CATAWBA OPERATIONS TRAINING Verifies KC flow to upper motor bearing oil cooler: NCP GRAPHIC or Annunciator 1AD-6 C/2 "NCP B MTR UPPER BRG KC OUTLET HilLa FLOW", Dark is normal.

Verifies KC flow to lower motor bearing oil cooler (NCP GRAPHIC or Annunciator 1AD-6 D/2 "NCP B MTR LOWER BRG KC OUTLET HilLa FLOW", Dark) is normal.

Verify alarm 1AD-11, Kl6 dark.

Depresses RED "ON" pushbutton for NC PMP OIL LIFT PMP B1 or B2 approximately two minutes prior to starting 1 B NC Pump.

Verifies RED "ON" light lit.

EXAMINER NOTE: Step 15 cannot be performed unless step 14 is completed satisfactorily.

CUE: Two minutes have elapsed.

Depress RED "ON" pushbutton for NC PMP 1 B. Verifies RED "ON" light lit and pump amps stabilized near midscale on ammeter.

NOTE: The following items 16a, b, c were checked previously on control board or OAC.

OP-CN-PS-NCP-OB1 FOR TRAINING PURPOSES ONL Y Page60fB REV. 12 DUKE POWER CATAWBA OPERATIONS TRAINING

  • indicates a "critical" step
11.
12.
13.
  • 14.
  • 15.

Verify KC flow to Upper Motor Brg. Oil Cooler normal, for the pump to be started.

Verify KC flow to Lower Motor Brg. Oil Cooler normal, for the pump to be started.

Verify "230KV Swyd Volt Lo" Annunciator on 1AD-11, Kl6 dark.

Two minutes prior to starting NC pump, start one oil lift pump for NCP to be started.

Start desired NC pump by pressing the "ON" pushbutton for:

"NC PMP 1B" STA~DARD Verifies KC flow to upper motor bearing oil cooler: NCP GRAPHIC or Annunciator 1AD-6 C/2 "NCP B MTR UPPER BRG KC OUTLET HilLa FLOW", Dark is normal.

Verifies KC flow to lower motor bearing oil cooler (NCP GRAPHIC or Annunciator 1AD-6D~"NCPBMTRLOWERBRGKC OUTLET HilLa FLOW", Dark) is normal.

Verify alarm 1AD-11, Kl6 dark.

Depresses RED "ON" pushbutton for NC PMP OIL LIFT PMP B1 or B2 approximately two minutes prior to starting 1 B NC Pump.

Verifies RED "ON" light lit.

EXAMINER NOTE: Step 15 cannot be performed unless step 14 is completed satisfactorily.

CUE: Two minutes have elapsed.

Depress RED "ON" pushbutton for NC PMP 1 B. Verifies RED "ON" light lit and pump amps stabilized near midscale on ammeter.

NOTE: The following items 16a, b, c were checked previously on control board or OAC.

OP-CN-PS-NCP-OB1 FOR TRAINING PURPOSES ONL Y Page 60fB REV. 12

. stu

16.
17.

DUKE POWER Observe all pump and motor parameters to verify proper operation.

Three minutes after flow in the affected NC loop exceeds 90%, stop the oil lift pump started previously.

CATAWBA OPERATIONS TRAINING Verifies pump and motor parameters indicating proper operations:

a. #1 Seal DIP greater than or equal to 200 psid.
b. Inlet Seal Water Flow 7-10 gpm (may be greater than 10 due to pump start)
c. #1 Seal Leakoff Flow appropriate for current Delta P per Revised Data Book Figure 26.
d. Pump Radial Bearing Temp less than 225°F (1MC5: 1 NVP5360 or NCP GRAPHIC).
e. #1 Seal Outlet Temp between 60°F &

235°F (1MC5: 1 NVP5400 or NCP GRAPHIC).

f. Pump Shaft Vibration less than 15 mils.

(NCP GRAPHIC or PANEL on rear of 1 MC-6).

g. Motor Bearings less than 190°F (NCP GRAPHIC).
h. Motor Winding Temp less than 302°F (NCP GRAPHIC).

I. Motor Frame Vibration less than 3 mils.

(NCP GRAPHIC or PANEL on rear of 1 MC-6).

Depress GREEN "OFF" pushbutton and verify GREEN "OFF" light lit.

END TIME: _____ _

OP-CN-PS-NCP-OB1 FOR TRAINING PURPOSES ONL Y Page 70fB REV. 12

16.
17.

DUKE POWER Observe all pump and motor parameters to verify proper operation.

Three minutes after flow in the affected NC loop exceeds 90%, stop the oil lift pump started previously.

CATAWBA OPERATIONS TRAINING STANDARD <

Verifies pump and motor parameters indicating proper operations:

a. #1 Seal DIP greater than or equal to 200 psid.
b. Inlet Seal Water Flow 7-10 gpm (may be greater than 10 due to pump start)
c. #1 Seal Leakoff Flow appropriate for current Delta P per Revised Data Book Figure 26.
d. Pump Radial Bearing Temp less than 225°F (1 MC5: 1 NVP5360 or NCP GRAPHIC).
e. #1 Seal Outlet Temp between 60°F &

235°F (1 MC5: 1 NVP5400 or NCP GRAPHIC).

f. Pump Shaft Vibration less than 15 mils.

(NCP GRAPHIC or PANEL on rear of 1 MC-6).

g. Motor Bearings less than 190°F (NCP GRAPHIC).
h. Motor Winding Temp less than 302°F (NCP GRAPHIC).

I. Motor Frame Vibration less than 3 mils.

(NCP GRAPHIC or PANEL on rear of 1 MC-6).

Depress GREEN "OFF" pushbutton and verify GREEN "OFF" light lit.

END TIME: _____

OP-CN-PS-NCP-OB1 FOR TRAINING PURPOSES ONL Y Page 70fB REV. 12 S/U

DUKE POWER CATAWBA OPERATIONS TRAINING INITIATING CUE:

EP/1/A/5000/ES-O.2, Natural Circulation Cooldown has been implemented following a Reactor Trip. Control problems with 1 NV-309 require the valve be operated in manual. The SRO instructs you to attempt to start NC Pump 1 B by completing OP/1/A/6150/002A, NC Pump Operation Encl. 4.1. The Initial Conditions of Encl. 4.1 have been satisfied.

OP-CN-PS-NCP-OB1 FOR TRAINING PURPOSES ONL Y Page B ofB REV. 12 DUKE POWER CATAWBA OPERATIONS TRAINING INITIATING CUE:

EP/1/A15000/ES-O.2, Natural Circulation Cooldown has been implemented following a Reactor Trip. Control problems with 1 NV-309 require the valve be operated in manual. The SRO instructs you to attempt to start NC Pump 1B by completing OP/1/A161501002A, NC Pump Operation Encl. 4.1. The Initial Conditions of Encl. 4.1 have been satisfied.

OP-CN-PS-NCP-081 FOR TRAINING PURPOSES ONL Y Page 80f8 REV. 12

CANDIDATE EXAMINER JPM09 H CATAWBA NUCLEAR STATION INITIAL LICENSE EXAMINATION JOB PERFORMANCE MEASURE JPM09 H Shift Operating RC Pumps Page 1 of 11 CANDIDATE EXAMINER JPM09 H CATAWBA NUCLEAR STATION INITIAL LICENSE EXAMINATION JOB PERFORMANCE MEASURE JPM09 H Shift Operating RC Pumps Page 1 of 11

Shift Operating RC Pumps.

Alternate Path:

YES Facility JPM #:

NRC BANK KIA Rating(s):

CATAWBA NUCLEAR STATION INITIAL LICENSE EXAMINATION JOB PERFORMANCE MEASURE SYS075 K4.01 Knowledge of circulating water system design feature(s) and interlocks which provide for the following: Heat Sink (CFR 41.7) 2.5/2.8 Task Standard:

1A and 1 D RC pumps are in service and 1 RC-22 is closed.

Preferred Evaluation Simulator:

Preferred Evaluation Perform Simulator X

In-Plant __ _

Perform _...:..X-,--

Simulate __ _

References:

OP/1/B/6400/001A (Condenser Circulating Water) Enclosure 4.7 rev 066 Validation Time: 10 min.

Time Critical: No

=======================================================================

Candidate:

Time Start: ___ _

NAME Time Finish: ___ _

Performance Rating:

SAT ___ UNSAT __ _ Question Grade --- Performance Time ---

Examiner: ____

....,...,...,...,....,.=-_____ _

NAME


~/------

SIGNATURE DATE

=======================================================================

COMMENTS JPM09 H Page 2 of 11 Shift Operating RC Pumps.

Alternate Path:

YES Facility JPM #:

NRC BANK KIA Rating(s):

CATAWBA NUCLEAR STATION INITIAL LICENSE EXAMINATION JOB PERFORMANCE MEASURE SYS075 K4.01 Knowledge of circulating water system design feature(s) and interlocks which provide for the following: Heat Sink (CFR 41.7) 2.5/2.8 Task Standard:

1A and 1 D RC pumps are in service and 1 RC-22 is closed.

Preferred Evaluation Simulator:

Preferred Evaluation Perform Simulator _..t..X!....-

In-Plant __ _

Perform X

Simulate ---

References:

OP/1/B/64001001A (Condenser Circulating Water) Enclosure 4.7 rev 066 Validation Time: 10 min.

Time Critical: No

=======================================================================

Candidate:

Time Start: ___ _

NAME Time Finish: ___ _

Performance Rating:

SAT ___ UNSAT __ _ Question Grade __ _ Performance Time ---

Examiner: ____________ _

NAME


~~~~ _____

~/_----

SIGNATURE DATE

=======================================================================

COMMENTS JPM09 H Page 2 of 11

SIMULATOR SETUP SHEET

1. Reset to any 50% power snap.
2. Ensure 1 A and 1 B RC pumps in service.
3. Insert XMT-RC063 (TRC_6960 RC PUMP B LOWER GUIDE BRG TEMP (OAC) VALUE = 235, RAMP 600
4. Insert LOA-RC066 (RACKOUT RC PMP 1B), VALUE= RACKOUT, EVENT=1, DELAY = 240 s
5. Insert VLV-RC011 F (RC23 CCW PUMP 1 C DISCHARGE VLV FAIL TO POSITION)

VALUE = 0, EVENT = 1, DELAY = 15 s

6. Insert EVENT 1 as: x13i159n (This is the ON pushbutton for 1C RC pump being depressed.)
7. SNAP to an open IC set.

SIMULATOR OPERATOR INSTRUCTIONS:

Do not go to RUN until the student is ready to proceed.

Tools/Equipment/Procedures Needed:

1. OP/1 IB/64001001 A (Condenser Circulating Water), Enclosure 4.7 rev 066 JPM09 H Page 3 of 11 SIMULATOR SETUP SHEET
1. Reset to any 50% power snap.
2. Ensure 1A and 1 B RC pumps in service.
3. Insert XMT-RC063 (TRC_6960 RC PUMP B LOWER GUIDE BRG TEMP (OAC) VALUE = 235, RAMP 600
4. Insert LOA-RC066 (RACKOUT RC PMP 1B), VALUE= RACKOUT, EVENT=1, DELAY = 240 s
5. Insert VLV-RC011 F (RC23 CCW PUMP 1 C DISCHARGE VLV FAIL TO POSITION)

VALUE = 0, EVENT = 1, DELAY = 15 s

6. Insert EVENT 1 as: x13i159n (This is the ON pushbutton for 1 C RC pump being depressed.)
7. SNAP to an open IC set.

SIMULATOR OPERATOR INSTRUCTIONS:

Do not go to RUN until the student is ready to proceed.

Tools/Equipment/Procedures Needed:

1. OP/1/B/64001001A (Condenser Circulating Water), Enclosure 4.7 rev 066 JPM09 H Page 3 of 11

READ TO OPERATOR DIRECTION TO TRAINEE:

I will explain the initial conditions, and state the task to be performed. All control room steps shall be performed for this JPM, including any required communications. I will provide initiating cues and reports on other actions when directed by you. Ensure you indicate to me when you understand your assigned task. To indicate that you have completed your assigned task return the handout sheet I provided you.

INITIAL CONDITIONS:

Unit 1 is operating at 50% power following repair of a condenser tube leak.

The turbine building rounds NLO reports severe vibration and noise coming from 1 B RC pump and states that the motor is extremely hot to the touch.

The NLO has checked out 1 C and 1 D RC Pump and they are not rotating in the reverse direction.

INITIATING CUES:

Start 1C RC Pump and secure 1B RC Pump per Enclosure 4.7 of OP/1 IB/64001001 A (Condenser Circulating Water). Initial Conditions are complete.

JPM09 H Page 4 of 11 READ TO OPERATOR DIRECTION TO TRAINEE:

I will explain the initial conditions, and state the task to be performed. All control room steps shall be performed for this JPM, including any required communications. I will provide initiating cues and reports on other actions when directed by you. Ensure you indicate to me when you understand your aSSigned task. To indicate that you have completed your assigned task return the handout sheet I provided you.

INITIAL CONDITIONS:

Unit 1 is operating at 50% power following repair of a condenser tube leak.

The turbine building rounds NLO reports severe vibration and noise coming from 1 B RC pump and states that the motor is extremely hot to the touch.

The NLO has checked out 1 C and 1 D RC Pump and they are not rotating in the reverse direction.

INITIATING CUES:

Start 1C RC Pump and secure 1B RC Pump per Enclosure 4.7 of OP/1 IB/64001001 A (Condenser Circulating Water). Initial Conditions are complete.

JPM09 H Page 4 of 11

START TIME: __

STEP 2.1:

2.1 Start the desired RC pump as follows:

2.1.1 Verify the RC pump to be started is NOT rotating in the reverse direction.

STANDARD: Per initiating cue it is NOT rotating in reverse.

COMMENTS:

STEP 2.1:

2.1.2 Ensure "RCP DISCH VALVE MODE SEL" in the "NORM" position.

STANDARD: Check switch in NORM position.

COMMENTS:

STEP 2.1 NOTE:

To start a third RC pump three cooling towers are required to be in service to meet the interlock. This is accomplished by temporarily opening a third tower inlet isolation, it will be reclosed by Step 2.3.

STANDARD: Acknowledges note.

COMMENTS:

JPM09 H SAT UNSAT

_SAT

_UNSAT

_SAT UNSAT Page 5 of 11 START TIME: __

STEP 2.1:

2.1 Start the desired RC pump as follows:

2.1.1 Verify the RC pump to be started is NOT rotating in the reverse direction.

STANDARD: Per initiating cue it is NOT rotating in reverse.

COMMENTS:

STEP 2.1:

2.1.2 Ensure "RCP DISCH VALVE MODE SEL" in the "NORM" position.

STANDARD: Check switch in NORM position.

COMMENTS:

STEP 2.1 NOTE:

To start a third RC pump three cooling towers are required to be in service to meet the interlock. This is accomplished by temporarily opening a third tower inlet isolation, it will be reclosed by Step 2.3.

STANDARD: Acknowledges note.

COMMENTS:

JPM09 H SAT UNSAT

_SAT

_UNSAT

_SAT UNSAT Page 5 of 11

STEP 2.1:

SAT 2.1.3.1 IF starting a third RC pump, indicate which cooling tower inlet isolation is closed:

D 1 RC-25 (Cool Twr 1A Inlet Isol)

UNSAT STANDARD: Examinee notes that 1 RC-25 is closed.

COMMENTS:

STEP 2.1: '

SAT 2.1.3.2 ENSURE all three cooling tower inlet isolation valves are open D 1 RC-25 (Cool Twr 1A Inlet Isol)

UNSAT STANDARD: Examinee opens 1 RC-25 by depressing the RED "OPEN" pushbutton and noting the RED "OPEN" light illuminates.

EXAMINER NOTE: This is a large valve and takes -3.5 minutes

.to stroke.

COMMENTS:

STEP 2.1.

NOTE; Wait approximately two minutes after starting an RC pump before stopping SAT the desired RC pump to allow flow to stabilize.

Following each configuration change, sufficient time should be allowed for RC Cooling Tower Levels to stabilize prior to aligning additional components UNSAT STANDARD: Examinee acknowledges notes.

COMMENTS:

JPM09 H Page 6 of 11 STEP 2.1:

SAT 2.1.3.1 IF starting a third RC pump, indicate which cooling tower inlet isolation is closed:

D 1 RC-25 (Cool Twr 1A Inlet Isol)

UNSAT STANDARD: Examinee notes that 1 RC-25 is closed.

COMMENTS:

STEP 2.1:.

SAT 2.1.3.2 ENSURE all three cooling tower inlet isolation valves are open D 1 RC-25 (Cool Twr 1A Inlet Isol)

UNSAT STANDARD: Examinee opens 1 RC-25 by depressing the RED "OPEN" pushbutton and noting the RED "OPEN" light illuminates.

EXAMINER NOTE: This is a large valve and takes -3.5 minutes

.to stroke.

COMMENTS:

STEP 2.1.

NOTE; Wait approximately two minutes after starting an RC pump before stopping SAT the desired RC pump to allow flow to stabilize.

Following each configuration change, sufficient time should be allowed for RC Cooling Tower Levels to stabilize prior to aligning additional components UNSAT STANDARD: Examinee acknowledges notes.

COMMENTS:

JPM09 H Page 6 of 11

STEP 2.1.

2.1.4 Start the desired RC pump STANDARD: Examinee starts 1C RC Pump per the initiating cue.

COMMENTS:

STEP 2.1:

2.1.5 Ensure that its discharge valve fully opens. (Valve begins to open six seconds after pump start.)

STANDARD: Examinee should note that valve 1 RC-23 begins to open and then recloses and 1 C RC pump trips.

EXAMINER NOTE:

Examinee should realize that it is critical that 1 B pump be shut down and that 1 D RC pump is available to start. Should go back and re-perform step 2.1.4 and 2.1.5 for 1 D RC pump.

EXAMINER CUE: If notified that 1 C RC pump discharge valve did NOT open provide the following cue: "Start 1 D RC Pump and secure 1 B RC Pump".

COMMENTS:

STEP 2.1.

NOTE; Wait approximately two minutes after starting an RC pump before stopping the desired RC pump to allow flow to stabilize.

Following each configuration change, sufficient time should be allowed for RC Cooling Tower Levels to stabilize prior to aligning additional components STANDARD: Examinee acknowledges notes.

COMMENTS:

JPM09 H SAT

_UNSAT Critical Step

_SAT

_UNSAT

_SAT UNSAT Page 7 of 11 STEP 2.1.

2.1.4 Start the desired RC pump STANDARD: Examinee starts 1 C RC Pump per the initiating cue.

COMMENTS:

STEP 2.1:

2.1.5 Ensure that its discharge valve fully opens. (Valve begins to open six seconds after pump start.)

STANDARD: Examinee should note that valve 1 RC-23 begins to open and then recloses and 1 C RC pump trips.

EXAMINER NOTE:

Examinee should realize that it is critical that 1 B pump be shut down and that 1 D RC pump is available to start.

Should go back and re-perform step 2.1.4 and 2.1.5 for 1 D RC pump.

EXAMINER CUE: If notified that 1 C RC pump discharge valve did NOT open provide the following cue: "Start 1 D RC Pump and secure 18 RC Pump".

COMMENTS:

STEP 2.1.

NOTE; Wait approximately two minutes after starting an RC pump before stopping the desired RC pump to allow flow to stabilize.

Following each configuration change, sufficient time should be allowed for RC Cooling Tower Levels to stabilize prior to aligning additional components STANDARD: Examinee acknowledges notes.

COMMENTS:

JPM09 H SAT UNSAT Critical Step SAT UNSAT SAT UNSAT Page 7 of 11

STEP 2.1.

2.1.4 Start the desired RC pump STANDARD: Examinee starts 1D RC Pump.

COMMENTS:

STEP 2.1:

2.1.6 Ensure that its discharge valve fully opens. (Valve begins to open six seconds after pump start.)

STANDARD: Examinee notes that 1 RC-24 reaches fully open.

COMMENTS:

STEP 2.2:

2.2 Stop the desired RC pump as follows:

2.2.1 Dispatch an operator to the cooling tower area to monitor for cooling tower overflow periodically for the next hour.

STANDARD: Dispatched operator as stated.

EXAMINER CUE: This is Rob, I will monitor Unit 1 Cooling Tower levels.

COMMENTS:

JPM09 H Critical Step SAT

_UNSAT SAT

_UNSAT Critical Step SAT

_UNSAT Page 8 of 11 STEP 2.1.

2.1.4 Start the desired RC pump STANDARD: Examinee starts 1 D RC Pump.

COMMENTS:

STEP 2.1:

2.1.6 Ensure that its discharge valve fully opens. (Valve begins to open six seconds after pump start.)

STANDARD: Examinee notes that 1 RC-24 reaches fully open.

COMMENTS:

STEP 2.2:

2.2 Stop the desired RC pump as follows:

2.2.1 Dispatch an operator to the cooling tower area to monitor for cooling tower overflow periodically for the next hour.

STANDARD: Dispatched operator as stated.

EXAMINER CUE: This is Rob, I will monitor Unit 1 Cooling Tower levels.

COMMENTS:

JPM09 H Critical Step SAT UNSAT SAT UNSAT Critical Step SAT UNSAT Page 8 of 11

STEP 2.2:

2.2.2 Close the discharge valve of the pump to be stopped:

D 1 RC-22 (RC Pump 1 B Disch Isol)

STANDARD: Depresses the CLOSE button for 1 RC-22 and noted the Green CLOSED light illuminates.

EXAMINER NOTE: The valve may take 1 minute to close.

EXAMINER NOTE: The 1 B RC Pump may trip before it can be manually secured~

COMMENTS:

STEP 2.2:

2.2.3 Ensure that the pump stops when the valve closes.

STANDARD: Notes the 1 B RC Pump GREEN "OFF" light is illuminated either because the valve has closed, or because it tripped off due to the malfunction.

COMMENTS:

STEP 2.3:

If step 2.1.3.1 indicates a cooling tower inlet isolation valve was initially closed, close that cooling tower inlet isolation valve:

1 RC-2S (Cool Twr 1A Inlet Isol)

STANDARD: Notes the 1 RC-2S was originally closed and recloses the valve ensuring the GREEN "CLSD" light illuminates when it closes.

COMMENTS:

JPM09 H Critical Step SAT

_UNSAT

_SAT

_UNSAT Critical Step

_SAT

_UNSAT Page 9 of 11 STEP 2.2:

2.2.2 Close the discharge valve of the pump to be stopped:

D 1 RC-22 (RC Pump 1 B Disch Isol)

STANDARD: Depresses the CLOSE button for 1 RC-22 and noted the Green CLOSED light illuminates.

EXAMINER NOTE: The valve may take 1 minute to close.

EXAMINER NOTE: The 1 B RC Pump may trip before it can be manually secured.

COMMENTS:

STEP 2.2:

2.2.3 Ensure that the pump stops when the valve closes.

STANDARD: Notes the 1B RC Pump GREEN "OFF" light is illuminated either because the valve has closed, or because it tripped off due to the malfunction.

COMMENTS:

STEP 2.3:

If step 2.1.3.1 indicates a cooling tower inlet isolation valve was initially closed, close that cooling tower inlet isolation valve:

1 RC-2S (Cool Twr 1A Inlet Isol)

STANDARD: Notes the 1 RC-2S was originally closed and recloses the valve ensuring the GREEN "CLSD" light illuminates when it closes.

COMMENTS:

JPM09 H Critical Step SAT UNSAT SAT UNSAT Critical Step

_SAT UNSAT Page 9 of 11

STEP 2.4:

Ensure the cooling towers are aligned properly for the number of pumps remaining in operation per the cooling tower configuration limits:

SAT Riser Bypasses Riser Bypasses Open Tower Inlets Open 3

3 2

o Passing Flow 2

2 o

o Isolated 1

1 2

o STANDARD: Notes configuration is proper. (see bold)

COMMENTS:

This JPM is com lete.

TIME STOP: __

JPM09 H RC Pumps Running 1 (Throttled) 2 (Throttled) 1 (Th,r",..,tltlorl 3

UNSAT Page 10 of 11 STEP 2.4:

Ensure the cooling towers are aligned properly for the number of pumps remaining in operation per the cooling tower configuration limits:

SAT Riser Bypasses Riser Bypasses Open Tower Inlets RC Pumps Open Passing Flow Isolated Running 3

2 1

1 (Throttled)

UNSAT 3

2 1

2 (Throttled) 2 0

2 1 (Throttled)

  • 0.

1 2

0 0

0 3

STANDARD: Notes configuration is proper. (see bold)

COMMENTS:

This JPM is complete.

TIME STOP: __

JPM09 H Page 10 of 11

CANDIDATE CUE SHEET (TO BE RETURNED TO EXAMINER UPON COMPLETION OF TASK)

INITIAL CONDITIONS:

Unit 1 is operating at 50% power following repair of a condenser tube leak.

The turbine building rounds NLO reports severe vibration and noise coming from 1 B RC pump and states that the motor is extremely hot to the touch.

The NLO has checked out 1 C and 1 D RC Pump and they are not rotating in the reverse direction.

INITIATING CUES:

Start 1C RC Pump and secure 1B RC Pump per Enclosure 4.7 of OP/1 IB/64001001 A (Condenser Circulating Water). Initial Conditions are complete.

CANDIDATE CUE SHEET (TO BE RETURNED TO EXAMINER UPON COMPLETION OF TASK)

INITIAL CONDITIONS:

Unit 1 is operating at 50% power following repair of a condenser tube leak.

The turbine building rounds NLO reports severe vibration and noise coming from 1 B RC pump and states that the motor is extremely hot to the touch.

The NLO has checked out 1 C and 1 D RC Pump and they are not rotating in the reverse direction.

INITIATING CUES:

Start 1 C RC Pump and secure 1 B RC Pump per Enclosure 4.7 of OP/1/B/64001001 A (Condenser Circulating Water). Initial Conditions are complete.

.7 Shifting of Operating RC Pumps

1. Initial Conditions 1.1 Review the Limits and Precautions.

OPil/B/6400/001 A Page 1 of3 1.2 Verify two or more RC pumps are running per Enclosure 4.2 (Placing Cooling Towers In Service).

2. Procedure NOTE:

If it is desired to swap which RC pumps are in service while reducing or increasing the number of RC pumps and cooling towers in service, this enclosure is used first..3 (Removing Cooling Towers From Service) is then used to remove RC pump(s) and cooling tower(s) from service OR Enclosure 4.2 (Placing Cooling Towers In Service) is then used to place RC pump(s) and cooling tower(s) in service.

2.1 Start the desired RC Pump as follows:

2.1.1 Verify the RC pump to be started is NOT rotating in the reverse direction.

2.1.2 Ensure "RCP DISCH VALVE MODE SEL" in the "NORM" position.

NOTE:

To start a third RC pump three cooling towers are required to be in service to meet the interlock. This is accomplished by temporarily opening the third tower inlet isolation, it will be reclosed by Step 2.3.

2.1.3 IF starting a third RC pump, perform the following:

2.1.3.1 Indicate below which cooling tower inlet isolation is closed:

o 1RC-25 (Cool Twr 1A Inlet Isol) o 1RC-26 (Cool Twr 1B Inlet Isol) o 1RC-27 (Cool Twr lC Inlet Isol) 2.1.3.2 Ensure all three cooling tower inlet isolation valves are open:

o 1RC-25 (Cool Twr 1A Inlet Isol) o 1RC-26 (Cool Twr 1B Inlet Isol) o 1RC-27 (Cool Twr 1C Inlet Isol).7 Shifting of Operating RC Pumps

1. Initial Conditions 1.1 Review the Limits and Precautions.

OPil/B/6400100 1 A Page 1 of3 1.2 Verify two or more RC pumps are running per Enclosure 4.2 (Placing Cooling Towers In Service).

2. Procedure NOTE:

If it is desired to swap which RC pumps are in service while reducing or increasing the number of RC pumps and cooling towers in service, this enclosure is used first..3 (Removing Cooling Towers From Service) is then used to remove RC pump(s) and cooling tower(s) from service OR Enclosure 4.2 (Placing Cooling Towers In Service) is then used to place RC pump(s) and cooling tower(s) in service.

2.1 Start the desired RC Pump as follows:

2.1.1 Verify the RC pump to be started is NOT rotating in the reverse direction.

2.1.2 Ensure "RCP DISCH VALVE MODE SEL" in the "NORM" position.

NOTE:

To start a third RC pump three cooling towers are required to be in service to meet the interlock. This is accomplished by temporarily opening the third tower inlet isolation, it will be reclosed by Step 2.3.

2.1.3 IF starting a third RC pump, perform the following:

2.1.3.1 Indicate below which cooling tower inlet isolation is closed:

o lRC-25 (Cool Twr lA Inlet Isol) o lRC-26 (Cool Twr IB Inlet Iso1) o lRC-27 (Cool Twr lC Inlet Isol) 2.1.3.2 Ensure all three cooling tower inlet isolation valves are open:

o lRC-25 (Cool Twr lA Inlet Isol) o lRC-26 (Cool Twr IB Inlet Isol) o lRC-27 (Cool Twr 1 C Inlet Isol)

.7 Shifting of Operating RC Pumps OP!l/B/64001001 A Page 2 of3 NOTE:

Wait approximately two minutes after starting an RC pump before stopping the desired RC pump to allow flow to stabilize.

Following each configuration change, sufficient time needs to be allowed for RC Cooling Tower Levels to stabilize prior to aligning additional components.

2.1.4 Start the desired RC pump 2.1.5 Ensure that its discharge valve fully opens. (Valve begins to open six seconds after pump start.)

2.2 Stop the desired RC pump as follows:

2.2.1 Dispatch an operator to the cooling tower area to monitor for cooling tower overflow periodically for the next hour.

2.2.2 Close the discharge valve of the pump to be stopped:

D 1RC-21 (RC Pump 1A Disch Isol)

D 1RC-22 (RC Pump 1B Disch Isol)

D 1RC-23 (RC Pump 1C Disch Isol)

D 1RC-24 (RC Pump 1D Disch Isol) 2.2.3 Ensure that the pump stops when the valve closes.

2.3 IF Step 2.1.3.1 indicates a cooling tower inlet isolation was initially closed, close that cooling tower inlet isolation.

D 1RC-25 (Cool Twr 1A Inlet Isol)

D 1RC-26 (Cool Twr 1B Inlet Iso1)

D 1RC-27 (Cool Twr 1C Inlet Isol) 2.4 Ensure the cooling towers are aligned properly for the number of pumps remaining in operation per the following cooling tower configuration limits:

Riser Bypasses Riser Bypasses Open Tower Inlets RCPumps Open Passing Flow Isolated Running 3

2 1

1 (Throttled) 3 2

1 2 (Throttled) 2 0

2 1 (Throttled) 1 0

1 2

0 0

0 3.7 Shifting of Operating RC Pumps OP!l/B/64001001 A Page 2 of3 NOTE:

Wait approximately two minutes after starting an RC pump before stopping the desired RC pump to allow flow to stabilize.

Following each configuration change, sufficient time needs to be allowed for RC Cooling Tower Levels to stabilize prior to aligning additional components.

2.1.4 Start the desired RC pump 2.1.5 Ensure that its discharge valve fully opens. (Valve begins to open six seconds after pump start.)

2.2 Stop the desired RC pump as follows:

2.2.1 Dispatch an operator to the cooling tower area to monitor for cooling tower overflow periodically for the next hour.

2.2.2 Close the discharge valve of the pump to be stopped:

D 1RC-21 (RC Pump 1A Disch Isol)

D 1RC-22 (RC Pump 1B Disch Isol)

D 1RC-23 (RC Pump 1C Disch Isol)

D 1RC-24 (RC Pump 1D Disch Isol) 2.2.3 Ensure that the pump stops when the valve closes.

2.3 IF Step 2.1.3.1 indicates a cooling tower inlet isolation was initially closed, close that cooling tower inlet isolation.

D 1RC-25 (Cool Twr 1A Inlet Isol)

D 1RC-26 (Cool Twr 1B Inlet Iso1)

D 1RC-27 (Cool Twr 1C Inlet Iso1) 2.4 Ensure the cooling towers are aligned properly for the number of pumps remaining in operation per the following cooling tower configuration limits:

Riser Bypasses Riser Bypasses Open T ower Inlets RC Pumps Open Passing Flow Isolated Running 3

2 1

1 (Throttled) 3 2

1 2 (Throttled) 2 0

2 1 (Throttled) 1 0

1 2

0 0

0 3

.7 Shifting of Operating RC Pumps 2.5 File this enclosure in the Control Copy folder of this procedure.

OP/I/B/6400/001 A Page 3 of3.7 Shifting of Operating RC Pumps 2.5 File this enclosure in the Control Copy folder of this procedure.

OPil/B/6400/001 A Page 3 of3

CATAWBA NUCLEAR STATION INITIAL LICENSE EXAMINATION JOB PERFORMANCE MEASURE JPM091 Transfer Control to the Standby Shutdown System CANDIDATE EXAMINER JPM091 Page 1 of 11 CATAWBA NUCLEAR STATION INITIAL LICENSE EXAMINATION JOB PERFORMANCE MEASURE JPM09 I Transfer Control to the Standby Shutdown System CANDIDATE EXAMINER JPM09 I Page 1 of 11

CATAWBA NUCLEAR STATION INITIAL LICENSE EXAMINATION JOB PERFORMANCE MEASURE Transfer Control to the Standby Shutdown System Alternate Path:

No Facility JPM #:

AD-001 KIA Rating(s):

APE068 AA 1.21 Ability to operate or monitor the following as they apply to the control room evacuation: Transfer of controls from the control room to shutdown panel or local control (3.9/4.1)

Task Standard:

Control is transferred to the Standby Shutdown System, solenoid isolation valve disconnects transferred, CAPT T&T valve power is transferred and Train A Neutron Monitoring System power is transferred.

Preferred Evaluation Simulator:

Preferred Evaluation Perform Simulator __ _

I n-Plant ~X:.!.-_

Perform __

Simulate _~X'--_

References:

OP/0/B/61 00/013 (Standby Shutdown Facility Operation) Enclosure 4.2 revision 049 Validation Time: 10 min.

Time Critical: No

=======================================================================

Candidate:

Time Start: __

NAME Time Finish: __

Performance Rating:

SAT ___ UNSAT __ _ Question Grade __ _ Performance Time __ _

Examiner: ________ ------

NAME


~~~~~ ____ ~/_~~

SIGNATURE DATE

=======================================================================

COMMENTS JPM091 Page 2 of 11 CATAWBA NUCLEAR STATION INITIAL LICENSE EXAMINATION JOB PERFORMANCE MEASURE Transfer Control to the Standby Shutdown System Alternate Path:

No Facility JPM #:

AD-001 KIA Rating(s):

APE068 AA 1.21 Ability to operate or monitor the following as they apply to the control room evacuation: Transfer of controls from the control room to shutdown panel or local control (3.9/4.1)

Task Standard:

Control is transferred to the Standby Shutdown System, solenoid isolation valve disconnects transferred, CAPT T&T valve power is transferred and Train A Neutron Monitoring System power is transferred.

Preferred Evaluation Simulator:

Preferred Evaluation Perform Simulator __ _

In-Plant ---,X-,--_

Perform __ _

Simulate _~X,---_

References:

OP/0/B/61 00/013 (Standby Shutdown Facility Operation) Enclosure 4.2 revision 049 Validation Time: 10 min.

Time Critical: No

=======================================================================

Candidate:

Time Start: ___ _

NAME Time Finish: ----

Performance Rating:

SAT ___ UNSAT __ _

Question Grade __ _

Performance Time __ _

Examiner: ____________ _

NAME


~~~~~~---~/_~~~

SIGNATURE DATE

=======================================================================

COMMENTS JPM091 Page 2 of 11

SIMULATOR SETUP SHEET N/A SIMULATOR OPERATOR INSTRUCTIONS:

N/A Tools/Equipment/Procedures Needed:

OP/0/B/61 001013 (Standby Shutdown Facility Operation) Enclosure 4.2 revision 049 JPM091 Page 3 of 11 SIMULATOR SETUP SHEET N/A SIMULATOR OPERATOR INSTRUCTIONS:

N/A Tools/Equipment/Procedures Needed:

OP/0/B/51 00/013 (Standby Shutdown Facility Operation) Enclosure 4.2 revision 049 JPM091 Page 3 of 11

READ TO OPERATOR DIRECTION TO TRAINEE:

I will explain the initial conditions, and state the task to be performed. All control room steps shall be performed for this JPM, including any required communications. I will provide initiating cues and reports on other actions when directed by you. Ensure you indicate to me when you understand your assigned task. To indicate that you have completed your assigned task return the handout sheet I provided you.

INITIAL CONDITIONS:

Unit 2 has just suffered a fire that results in evacuation of the control room.

INITIATING CUES:

Transfer control to the Standby Shutdown System per OP/O/B/61 001013 Enclosure 4.2 steps 2.1 through 2.4. All initial conditions have been satisfied.

JPM091 Page 4 of 11 READ TO OPERATOR DIRECTION TO TRAINEE:

I will explain the initial conditions, and state the task to be performed. All control room steps shall be performed for this JPM, including any required communications. I will provide initiating cues and reports on other actions when directed by you. Ensure you indicate to me when you understand your assigned task. To indicate that you have completed your assigned task return the handout sheet I provided you.

INITIAL CONDITIONS:

Unit 2 has just suffered a fire that results in evacuation of the control room.

INITIATING CUES:

Transfer control to the Standby Shutdown System per OP/0/S/61 00/013 Enclosure 4.2 steps 2.1 through 2.4. All initial conditions have been satisfied.

JPM091 Page 4 of 11

START TIME: __

STEP 2.1:

Transfer control to the Standby Shutdown System (SSS) as follows:

NOTE: These breakers are kirk-key interlocked to prevent both feeders from being closed at the same time.

STANDARD: Acknowledges note.

COMMENTS:

STEP 2.1.1:

Open 2EMXS-F01A (Normal Incoming Breaker Fed From Motor Control Center 2EMXA) (AB-577, BB-65, Rm 486).

STANDARD: Rotate 2EMXS-F01A switch to "OFF".

EXAMINER CUE: "2EMXS-F01A is OFF."

COMMENTS:

STEP 2.1.2 Close 2EMXS-F03A (Alternate Incoming Bkr Fed From Motor Control Center SMXG)

STANDARD: Rotate Kirk-Key in 2EMXS-F01A and remove.

Insert Kirk-Key in 2EMXS-F03A and rotate.

Rotate 2EMXS-F03A switch to "ON" EXAMINER NOTE: Kirk Key must be obtained from 2EMXS-F01A to be inserted into 2EMXS-F03A.

EXAMINER CUE: "2EMXS-F03A is ON."

COMMENTS:

JPM09 I SAT

_UNSAT CRITICAL STEP SAT

_UNSAT CRITICAL STEP SAT

_UNSAT Page 5 of 11 START TIME: __

STEP 2.1:

Transfer control to the Standby Shutdown System (SSS) as follows:

NOTE: These breakers are kirk-key interlocked to prevent both feeders from being closed at the same time.

STANDARD: Acknowledges note.

COMMENTS:

STEP 2.1.1:

Open 2EMXS-F01A (Normal Incoming Breaker Fed From Motor Control Center 2EMXA) (AB-577, BB-65, Rm 486).

STANDARD: Rotate 2EMXS-F01A switch to "OFF".

EXAMINER CUE: "2EMXS-F01A is OFF."

COMMENTS:

STEP 2.1.2 Close 2EMXS-F03A (Alternate Incoming Bkr Fed From Motor Control Center SMXG)

STANDARD: Rotate Kirk-Key in 2EMXS-F01A and remove.

Insert Kirk-Key in 2EMXS-F03A and rotate.

Rotate 2EMXS-F03A switch to "ON" EXAMINER NOTE: Kirk Key must be obtained from 2EMXS-F01A to be inserted into 2EMXS-F03A.

EXAMINER CUE: "2EMXS-F03A is ON."

COMMENTS:

JPM091 SAT

_UNSAT CRITICAL STEP SAT

_UNSAT CRITICAL STEP SAT

_UNSAT Page 5 of 11

STEP 2.1.3:

Close 2EMXS-F03E (Reactor Vessel Head Vent Motor (2NC253A) to restore power to 2NC-253A (Rx Head Vent).

STANDARD: Rotate 2EMXS-F03E switch to "ON".

EXAMINER CUE: "2EMXS-F03E is ON."

COMMENTS:

STEP 2.2:

Ensure significant solenoid isolation valve are closed by transferring disconnects as follows:

CAUTION: The plugs shall be inserted squarely and the ring tightened to ensure proper connection of all pins.

STANDARD: Acknowledges Caution.

COMMENTS:

STEP 2.2.1:

Remove Train A Plug 1 disconnect from the "PLUG 1: PLANT MODE" receptacle and connect to the" PLUG 1: SSF MODE" receptacle located in terminal box 2TBOX0396 (Train A SSF Disconnect Enclosure) (AB-577, BB-69, Rm 486).

STANDARD: Rotate lock ring and remove Train "A" Plug 1 from "PLANT MODE" and place in "SSF MODE" receptacle and tighten lock ring EXAMINER CUE: "Train "A" Plug 1 is installed in "SSF Mode".

COMMENTS:

JPM09 I CRITICAL STEP

_SAT

_UNSAT

_SAT

_UNSAT CRITICAL STEP

_SAT

_UNSAT Page 6 of 11 STEP 2.1.3:

Close 2EMXS-F03E (Reactor Vessel Head Vent Motor (2NC253A) to restore power to 2NC-253A (Rx Head Vent).

STANDARD: Rotate 2EMXS-F03E switch to "ON".

EXAMINER CUE: "2EMXS-F03E is ON."

COMMENTS:

STEP 2.2:

Ensure significant solenoid isolation valve are closed by transferring disconnects as follows:

CAUTION: The plugs shall be inserted squarely and the ring tightened to ensure proper connection of all pins.

STANDARD: Acknowledges Caution.

COMMENTS:

STEP 2.2.1:

Remove Train A Plug 1 disconnect from the "PLUG 1: PLANT MODE" receptacle and connect to the" PLUG 1: SSF MODE" receptacle located in terminal box 2T80X0396 (Train A SSF Disconnect Enclosure) (A8-577, 88-69, Rm 486).

STANDARD: Rotate lock ring and remove Train "A" Plug 1 from "PLANT MODE" and place in "SSF MODE" receptacle and tighten lock ring EXAMINER CUE: "Train "A" Plug 1 is installed in "SSF Mode".

COMMENTS:

JPM09 I CRITICAL STEP

_SAT

_UNSAT SAT UNSAT CRITICAL STEP SAT UNSAT Page 6 of 11

STEP 2.2.2 Remove Train A Plug 2 disconnect from the" PLUG 2: PLANT MODE" receptacle and connect to the" PLUG 2: SSF MODE" receptacle located in terminal box 2TBOX0396 (Train A SSF Disconnect Enclosure) (AB-577, BB-69, Rm 486).

STANDARD: Rotate locking ring and Remove Train "B" disconnect from "PLANT MODE" and place in "SSF MODE" receptacle and tighten lock ring.

EXAMINER CUE: "Train "A" Plug 2 is installed in "SSF Mode".

COMMENTS:

STEP 2.2.3:

Remove Train B disconnect from the "PLANT OPERATION" receptacle and connect to the "SSF OPERATION" receptacle located in 2TBOX0395 (Train B SSF Disconnect Enclosure) (inside small door "Unit 2 Auxiliary Building SSF Disconnect") (AB-577, BB-69, Rm 486).

STANDARD: Rotate locking ring and Remove Train "B" disconnect from "PLANT OPERATION" and place in "SSF OPERATION" receptacle and tighten lock ring.

EXAMINER CUE: "Train "8" disconnect is installed in "SSF OPERATION."

COMMENTS:

NOTE: The power disconnect breaker for 2NC-252B (Rx Head Vent Block) is located in 2TBOX0395 (Train B SSF Disconnect Enclosure) (inside small door "Unit 2 Auxiliary Building SSF Disconnect") (AB-577, BB-69, Rm 486).

STANDARD: Acknowledges note.

COMMENTS:

JPM09 I CRITICAL STEP SAT UNSAT CRITICAL STEP SAT UNSAT SAT UNSAT Page 7 of 11 STEP 2.2.2 Remove Train A Plug 2 disconnect from the" PLUG 2: PLANT MODE" receptacle and connect to the" PLUG 2: SSF MODE" receptacle located in terminal box 2TBOX0396 (Train A SSF Disconnect Enclosure) (AB-577, BB-69, Rm 486).

STANDARD: Rotate locking ring and Remove Train "B" disconnect from "PLANT MODE" and place in "SSF MODE" receptacle and tighten lock ring.

EXAMINER CUE: "Train "A" Plug 2 is installed in "SSF Mode".

COMMENTS:

STEP 2.2.3:

Remove Train B disconnect from the "PLANT OPERATION" receptacle and connect to the "SSF OPERATION" receptacle located in 2TBOX0395 (Train B SSF Disconnect Enclosure) (inside small door "Unit 2 Auxiliary Building SSF Disconnect") (AB-577, BB-69, Rm 486).

STANDARD: Rotate locking ring and Remove Train "B" disconnect from "PLANT OPERATION" and place in "SSF OPERATION" receptacle and tighten lock ring.

EXAMINER CUE: "Train "8" disconnect is installed in "SSF OPERATION."

COMMENTS:

NOTE: The power disconnect breaker for 2NC-252B (Rx Head Vent Block) is located in 2TBOX0395 (Train B SSF Disconnect Enclosure) (inside small door "Unit 2 Auxiliary Building SSF Disconnect") (AB-577, BB-69, Rm 486).

STANDARD: Acknowledges note.

COMMENTS:

JPM09 I CRITICAL STEP SAT

_UNSAT CRITICAL STEP SAT UNSAT SAT UNSAT Page 7 of 11

STEP 2.2.4 Ensure the 600V power disconnect breaker (SSF Pwr Disconnect For 2NC-252B) for 2NC-252B (Rx Head Vent Block) is in the "OFF" position.

STANDARD: Ensures 2NC-252B disconnect BKR in "OFF" position.

EXAMINER CUE: "2NC-252 disconnect BKR is in the OFF position" COMMENTS:

STEP 2.3 Transfer power for CAPT Trip and Throttle valve as follows:

NOTE: These breakers are Kirk-Key interlocked to prevent both feeders from being closed at the same time. (on 2ELCP0250 (125 VDC CAPT Trip And Throttle Valve Power Transfer Panel>>

STANDARD: Acknowledges note.

COMMENTS:

STEP 2.3.1:

Open 2ELCP0250-F01 B (Incoming Line From 2EDE 125 VDC 1 E) (AB-577, BB-64, Rm 486).

STANDARD: Rotate 2ELCP0250-F01B, switch to :"OFF".

EXAMINER CUE: "2ELCP0250-F01 B is OFF" COMMENTS:

JPM091 SAT UNSAT SAT UNSAT CRITICAL STEP SAT UNSAT Page 8 of 11 STEP 2.2.4 Ensure the 600V power disconnect breaker (SSF Pwr Disconnect For 2NC-252B) for 2NC-252B (Rx Head Vent Block) is in the "OFF" position.

STANDARD: Ensures 2NC-252B disconnect BKR in "OFF" position.

EXAMINER CUE: "2NC-252 disconnect BKR is in the OFF position" COMMENTS:

STEP 2.3 Transfer power for CAPT Trip and Throttle valve as follows:

NOTE: These breakers are Kirk-Key interlocked to prevent both feeders from being closed at the same time. (on 2ELCP0250 (125 VDC CAPT Trip And Throttle Valve Power Transfer Panel>>

STANDARD: Acknowledges note.

COMMENTS:

STEP 2.3.1:

Open 2ELCP0250-F01B (Incoming Line From 2EDE 125 VDC 1E) (AB-577, BB-64, Rm 486).

STANDARD: Rotate 2ELCP0250-F01B, switch to :"OFF".

EXAMINER CUE: "2ELCP0250-F01 B is OFF" COMMENTS:

JPM091 SAT UNSAT SAT UNSAT CRITICAL STEP SAT UNSAT Page 8 of 11

STEP 2.3.2 Close 2ELCP0250-F01C (Incoming Line From SDSP2 125 VDC NE).

STANDARD: Rotate Kirk-Key in 2ELCP0250-F01 B and remove.

Insert Kirk-Key in 2ELCP0250-F01 C and rotate.

Rotate 2ELCP0250-F01 C switch to "ON" EXAMINER NOTE: Kirk Key must be obtained from 2ELCP0250-F01 B to be inserted into 2ELCP0250-F01 C.

EXAMINER CUE: "2ELCP0250*F01C switch to "ON""

COMMENTS:

STEP 2.4 Transfer power to Train A Neutron Monitoring System as follows: (2TBOX0603, AB-577, BB-62, Rm 486) 2.4.1 Disconnect the power plug from the "NORMAL IE OPERATION" receptacle.

STANDARD: Rotate lock ring and remove plug from "NORMAL IE OPERATION" EXAMINER CUE: "Power Plug is disconnected."

COMMENTS:

JPM091 CRITICAL STEP SAT

_UNSAT CRITICAL STEP SAT UNSAT Page 9 of 11 CRITICAL STEP STEP 2.3.2 SAT Close 2ELCP0250-F01 C (Incoming Line From SDSP2 125 VDC NE).

STANDARD: Rotate Kirk-Key in 2ELCP0250-F01 B and remove.

Insert Kirk-Key in 2ELCP0250-F01 C and rotate.

UNSAT Rotate 2ELCP0250-F01 C switch to "ON" EXAMINER NOTE: Kirk Key must be obtained from 2ELCP0250-F01 B to be inserted into 2ELCP0250-F01 C.

EXAMINER CUE: "2ELCP0250*F01C switch to "ON""

COMMENTS:

CRITICAL STEP STEP 2.4 Transfer power to Train A Neutron Monitoring System as follows: (2TBOX0603, AB-577, BB-62, Rm 486)

SAT 2.4.1 Disconnect the power plug from the "NORMAL IE OPERATION" receptacle.

STANDARD: Rotate lock ring and remove plug from "NORMAL IE OPERATION" UNSAT EXAMINER CUE: "Power Plug is disconnected."

COMMENTS:

JPM091 Page 9 of 11

CRITICAL STEP STEP 2.4.2 CAUTION: The plug shall be inserted squarely and the ring tightened to ensure proper connection of all pins.

SAT Connect the power plug to the "SSF NE OPERATION" receptacle.

STANDARD: Acknowledges caution and Installs power plug in "SSF NE UNSAT OPERATION" receptacle and tighten lock ring.

EXAMINER CUE: "Power Plug is connected."

COMMENTS:

This JPM is complete.

TIME STOP: __

JPM091 Page 10 of 11 CRITICAL STEP STEP 2.4.2 CAUTION: The plug shall be inserted squarely and the ring tightened to ensure proper connection of all pins.

SAT Connect the power plug to the "SSF NE OPERATION" receptacle.

STANDARD: Acknowledges caution and Installs power plug in "SSF NE UNSAT OPERATION" receptacle and tighten lock ring.

EXAMINER CUE: "Power Plug is connected."

COMMENTS:

This JPM is complete.

TIME STOP: __

JPM091 Page 10 of 11

CANDIDATE CUE SHEET (TO BE RETURNED TO EXAMINER UPON COMPLETION OF TASK)

INITIAL CONDITIONS:

Unit 2 has just suffered a fire that results in evacuation of the control room.

INITIATING CUES:

Transfer control to the Standby Shutdown System per OP/0/B/61 001013 Enclosure 4.2 steps 2.1 through 2.4. All initial conditions have been satisfied.

CANDIDATE CUE SHEET (TO BE RETURNED TO EXAMINER UPON COMPLETION OF TASK)

INITIAL CONDITIONS:

Unit 2 has just suffered a fire that results in evacuation of the control room.

INITIATING CUES:

Transfer control to the Standby Shutdown System per OP/0/S/61 00/013 Enclosure 4.2 steps 2.1 through 2.4. All initial conditions have been satisfied.

.2 OP/O/B/6100/013 Maintaining Unit 2 in Hot Standby Following Page 1 of 11 a Fire Event

1. Initial Conditions 1.1 Review the Limits and Precautions.

1.2 Preferred controls necessary to maintain Hot Standby (Control Room and Auxiliary Shutdown Panels) are unresponsive or NOT accessible due to fire.

1.3 The following actions have been completed by AP/2/A/5500/017 (Loss of Control Room).

D Reactor tripped D Turbine tripped D All NC pumps tripped D CFPTs tripped

2. Procedure NOTE:
1. NC System will NOT be able to be cooled down below approximately 567°F, because the lowest steam line safety valve is set at 1175 psig.
2. Steps 2.1 through 2.5 may be in progress per AP/21A15500/017 (Loss of Control Room), Enclosure 8 (Transfer Control to SSF) and APilIAl5500/017 (Loss of Control Room), Enclosure 10 (SSF DIG Startup).
3. Steps 2.1 through 2.4 may be performed concurrently with Steps 2.5 through 2.8.
4. For a list of valves affected by the transfer, see Enclosure 4.6 (Equipment Affected on Transfer).

2.1 Transfer control to the Standby Shutdown System (SSS) as follows:

NOTE:

These breakers are kirk-key interlocked to prevent both feeders from being closed at the same time.

D 2.1.1 D 2.1.2 D 2.1.3 Open 2EMXS-FOIA (Normal Incoming Breaker Fed From Motor Control Center 2EMXA) (AB-577, BB-65, Rm 486).

Close 2EMXS-F03A (Alternate Incoming Bkr Fed From Motor Control Center SMXG).

Close 2EMXS-F03E (Reactor Vessel Head Vent Motor (2NC253A)) to restore power to 2NC-253A (Rx Head Vent)..2 OP/O/B/61001013 Maintaining Unit 2 in Hot Standby Following Page 1 of 11 a Fire Event

1. Initial Conditions 1.1 Review the Limits and Precautions.

1.2 Preferred controls necessary to maintain Hot Standby (Control Room and Auxiliary Shutdown Panels) are unresponsive or NOT accessible due to fire.

1.3 The following actions have been completed by AP/2/A/55001017 (Loss of Control Room).

D Reactor tripped D Turbine tripped D All NC pumps tripped D CFPTs tripped

2. Procedure NOTE:
1. NC System will NOT be able to be cooled down below approximately 567°F, because the lowest steam line safety valve is set at 1175 psig.
2. Steps 2.1 through 2.5 may be in progress per AP/2IA155001017 (Loss of Control Room), Enclosure 8 (Transfer Control to SSF) and AP/lIAl55001017 (Loss of Control Room), Enclosure 10 (SSF DIG Startup).
3. Steps 2.1 through 2.4 may be performed concurrently with Steps 2.5 through 2.8.
4. For a list of valves affected by the transfer, see Enclosure 4.6 (Equipment Affected on Transfer).

2.1 Transfer control to the Standby Shutdown System (SSS) as follows:

NOTE:

These breakers are kirk-key interlocked to prevent both feeders from being closed at the same time.

D 2.1.1 D 2.1.2 D 2.1.3 Open 2EMXS-FOIA (Normal Incoming Breaker Fed From Motor Control Center 2EMXA) (AB-577, BB-65, Rm 486).

Close 2EMXS-F03A (Alternate Incoming Bkr Fed From Motor Control Center SMXG).

Close 2EMXS-F03E (Reactor Vessel Head Vent Motor (2NC253A)) to restore power to 2NC-253A (Rx Head Vent).

.2 OP/O/B/61001013 Maintaining Unit 2 in Hot Standby Following Page 2 of 11 a Fire Event 2.2 Ensure significant solenoid isolation valves are closed as follows:

CAUTION: The plugs shall be inserted squarely and the ring tightened to ensure proper connection of all pins.

D 2.2.1 D 2.2.2 D 2.2.3 Remove Train A Plug 1 disconnect from the "PLUG 1: PLANT MODE" receptacle and connect to the" PLUG 1: SSF MODE" receptacle located in terminal box 2TBOX0396 (Train A SSF Disconnect Enclosure) (AB-577, BB-69, Rm 486).

Remove Train A Plug 2 disconnect from the" PLUG 2: PLANT MODE" receptacle and connect to the" PLUG 2: SSF MODE" receptacle located in terminal box 2TBOX0396 (Train A SSF Disconnect Enclosure) (AB-577, BB-69, Rm 486).

Remove Train B disconnect from the "PLANT OPERATION" receptacle and connect to the "SSF OPERATION" receptacle located in 2TBOX0395 (Train B SSF Disconnect Enclosure) (inside small door "Unit 2 Auxiliary Building SSF Disconnect") (AB-577, BB-69, Rm 486).

NOTE:

The power disconnect breaker for 2NC-252B (Rx Head Vent Block) is located in 2TBOX0395 (Train B SSF Disconnect Enclosure) (inside small door "Unit 2 Auxiliary Building SSF Disconnect") (AB-577, BB-69, Rm 486).

D 2.2.4 Ensure the 600V power disconnect breaker (SSF Pwr Disconnect For 2NC-252B) for 2NC-252B (Rx Head Vent Block) is in the "OFF" position.

2.3 Transfer power for CAPT Trip and Throttle valve as follows:

NOTE:

These breakers are Kirk-Key interlocked to prevent both feeders from being closed at the same time. (on 2ELCP0250 (125 VDC CAPT Trip And Throttle Valve Power Transfer Panel))

D 2.3.1 D 2.3.2 Open 2ELCP0250-FOIB (Incoming Line From 2EDE 125 VDC IE) (AB-577, BB-64, Rm 486).

Close 2ELCP0250-FOIC (Incoming Line From SDSP2 125 VDC NE)..2 OP/O/B/61001013 Maintaining Unit 2 in Hot Standby Following Page 2 of 11 a Fire Event 2.2 Ensure significant solenoid isolation valves are closed as follows:

CAUTION:

The plugs shall be inserted squarely and the ring tightened to ensure proper connection of all pins.

D 2.2.1 D 2.2.2 D 2.2.3 Remove Train A Plug 1 disconnect from the "PLUG 1: PLANT MODE" receptacle and connect to the" PLUG 1: SSF MODE" receptacle located in terminal box 2TBOX0396 (Train A SSF Disconnect Enclosure) (AB-577, BB-69, Rm 486).

Remove Train A Plug 2 disconnect from the" PLUG 2: PLANT MODE" receptacle and connect to the" PLUG 2: SSF MODE" receptacle located in terminal box 2TBOX0396 (Train A SSF Disconnect Enclosure) (AB-577, BB-69, Rm 486).

Remove Train B disconnect from the "PLANT OPERATION" receptacle and connect to the "SSF OPERATION" receptacle located in 2TBOX0395 (Train B SSF Disconnect Enclosure) (inside small door "Unit 2 Auxiliary Building SSF Disconnect") (AB-577, BB-69, Rm 486).

NOTE:

The power disconnect breaker for 2NC-252B (Rx Head Vent Block) is located in 2TBOX0395 (Train B SSF Disconnect Enclosure) (inside small door "Unit 2 Auxiliary Building SSF Disconnect") (AB-577, BB-69, Rm 486).

D 2.2.4 Ensure the 600V power disconnect breaker (SSF Pwr Disconnect For 2NC-252B) for 2NC-252B (Rx Head Vent Block) is in the "OFF" position.

2.3 Transfer power for CAPT Trip and Throttle valve as follows:

NOTE:

These breakers are Kirk-Key interlocked to prevent both feeders from being closed at the same time. (on 2ELCP0250 (125 VDC CAPT Trip And Throttle Valve Power Transfer Panel))

D 2.3.1 D 2.3.2 Open 2ELCP0250-FOIB (Incoming Line From 2EDE 125 VDC IE) (AB-577, BB-64, Rm 486).

Close 2ELCP0250-FOIC (Incoming Line From SDSP2 125 VDC NE).

.2 OP/O/B/61 00/0 13 Maintaining Unit 2 in Hot Standby Following Page 3 of 11 a Fire Event 2.4 Transfer power to Train A Neutron Monitoring System as follows: (2TBOX0603, AB-577, BB-62, Rm 486)

D 2.4.1 Disconnect the power plug from the "NORMAL IE OPERATION" receptacle.

CAUTION: The plug shall be inserted squarely and the ring tightened to ensure proper connection of all pins.

D 2.4.2 Connect the power plug to the "SSF NE OPERATION" receptacle.

2.5 IF at any time power is lost to ISLXG as indicated by "LINE VOLTS" voltmeter (located on SSF Control Console panel), place SSF diesel in operation as follows:

CAUTION: The emergency mode overrides the SSF Diesel Generator "High Jacket Water Temperature" and "Low Lube Oil Pressure" trips.

D 2.5.1 D 2.5.2 D 2.5.3 D 2.5.4 D 2.5.5 D 2.5.6 Ensure the "SSF DIG MODE" switch is in the "EMERG" position on the SSF console.

Place the "SSF DIG" switch in the "ON" position.

IF the engine does NOT start within 30 seconds, perform the following:

D 2.5.3.1 D 2.5.3.2 D 2.5.3.3 Place the "SSF DIG" switch in the "OFF" position.

IF DIG turned over but did NOT fire during the DIG start attempt, turn the manual override knob on the shutdown valve (shown in.7, Top View of Fuel Oil Pump) clockwise to permit fuel flow through the valve.

After 1 to 2 minutes has passed, return to Step 2.5.2 to attempt to re-start the DIG.

Adjust "SSF DIG VOLT ADmST" until generator voltage is 600 volts.

Adjust the "SSF DIG GOV CTRL" to bring frequency to 60 +/- 1.2 Hz.

Press the "TRIP" pushbutton on "ISLXG NORM FDR FRM 1 TA" on the SSF console..2 OP/O/B/61001013 Maintaining Unit 2 in Hot Standby Following Page 3 of 11 a Fire Event 2.4 Transfer power to Train A Neutron Monitoring System as follows: (2TBOX0603, AB-577, BB-62, Rm 486) o 2.4.1 Disconnect the power plug from the "NORMAL IE OPERATION" receptacle.

CAUTION:

The plug shall be inserted squarely and the ring tightened to ensure proper connection of all pins.

o 2.4.2 Connect the power plug to the "SSF NE OPERATION" receptacle.

2.5 IF at any time power is lost to ISLXG as indicated by "LINE VOLTS" voltmeter (located on SSF Control Console panel), place SSF diesel in operation as follows:

CAUTION: The emergency mode overrides the SSF Diesel Generator "High Jacket Water Temperature" and "Low Lube Oil Pressure" trips.

o 2.5.1 o 2.5.2 o 2.5.3 o 2.5.4 o 2.5.5 o 2.5.6 Ensure the "SSF DIG MODE" switch is in the "EMERG" position on the SSF console.

Place the "SSF DIG" switch in the "ON" position.

IF the engine does NOT start within 30 seconds, perform the following:

o 2.5.3.1 o 2.5.3.2 o 2.5.3.3 Place the "SSF DIG" switch in the "OFF" position.

IF DIG turned over but did NOT fire during the DIG start attempt, turn the manual override knob on the shutdown valve (shown in.7, Top View of Fuel Oil Pump) clockwise to permit fuel flow through the valve.

After 1 to 2 minutes has passed, return to Step 2.5.2 to attempt to re-start the DIG.

Adjust "SSF DIG VOLT ADJUST" until generator voltage is 600 volts.

Adjust the "SSF DIG GOV CTRL" to bring frequency to 60 +/- 1.2 Hz.

Press the "TRIP" pushbutton on "ISLXG NORM FDR FRM ITA" on the SSF console.

CATAWBA NUCLEAR STATION INITIAL LICENSE EXAMINATION JOB PERFORMANCE MEASURE JPM09 J Locally Operate Steam Generator PORVs During a SGTR CANDIDATE EXAMINER JPM09 J Page 1 of 10 CATAWBA NUCLEAR STATION INITIAL LICENSE EXAMINATION JOB PERFORMANCE MEASURE JPM09 J Locally Operate Steam Generator PORVs During a SGTR CANDIDATE EXAMINER JPM09 J Page 1 of 10

CATAWBA NUCLEAR STATION INITIAL LICENSE EXAMINATION JOB PERFORMANCE MEASURE Locally Operate Steam Generator PORVs During a SGTR Alternate Path:

No Facility JPM #:

EP4-009 KIA Rating(s):

EPE038 EA 1.41 Venting of the S/G to the atmosphere (3.4/3.4)

Task Standard:

Steam Generator PORV 2SV-1 is manually engaged for local operation and the operator has demonstrated rotation of the handwheel in the proper direction to open the valve within 18 minutes Preferred Evaluation Simulator:

Preferred Evaluation Perform Simulator __ _

In-Plant ----'X'-!.-_

Perform __

Simulate _.!...:X,--_

References:

EP/2/N5000/E-3 (Steam Genratior Tube Rupture) Enclosure 3 revision 032 Validation Time: 10 min.

Time Critical: Yes 12 minutes

=======================================================================

Candidate:

Time Start: __

NAME Time Finish: __

Performance Rating:

SAT ___ UNSAT __ _ Question Grade __ _ Performance Time __ _

Examiner: ____________ _


~/_--

NAME SIGNATURE DATE

=======================================================================

COMMENTS JPM09 J Page 2 of 10 CATAWBA NUCLEAR STATION INITIAL LICENSE EXAMINATION JOB PERFORMANCE MEASURE Locally Operate Steam Generator PORVs During a SGTR Alternate Path:

No Facility JPM #:

EP4-009 KIA Rating(s):

EPE038 EA 1.41 Venting of the S/G to the atmosphere (3.4/3.4)

Task Standard:

Steam Generator PORV 2SV-1 is manually engaged for local operation and the operator has demonstrated rotation of the handwheel in the proper direction to open the valve within 18 minutes Preferred Evaluation Simulator:

Preferred Evaluation Perform Simulator __ _

I n-PI ant -----'X..:.-_

Perform __

Simulate _.:....:X,--_

References:

EP/2/N5000/E-3 (Steam Genratior Tube Rupture) Enclosure 3 revision 032 Validation Time: 10 min.

Time Critical: Yes 12 minutes

=======================================================================

Candidate:

Time Start: __

NAME Time Finish: __

Performance Rating:

SAT ___ UNSAT __ _ Question Grade --- Performance Time ---

Examiner: ____________ _


~/_--

NAME SIGNATURE DATE

=======================================================================

COMMENTS JPM09 J Page 2 of 10

SIMULATOR SETUP SHEET N/A SIMULATOR OPERATOR INSTRUCTIONS:

N/A Tools/Equipment/Procedures Needed:

EP/21A15000/E-3 (Steam Generator Tube Rupture) Enclosure 3 revision 032 JPM09 J Page 3 of 10 SIMULATOR SETUP SHEET N/A SIMULATOR OPERATOR INSTRUCTIONS:

N/A Tools/Equipment/Procedures Needed:

EP/2/A/5000/E-3 (Steam Generator Tube Rupture) Enclosure 3 revision 032 JPM09 J Page 3 of 10

READ TO OPERATOR DIRECTION TO TRAINEE:

I will explain the initial conditions, and state the task to be performed. All control room steps shall be performed for this JPM, including any required communications. I will provide initiating cues and reports on other actions when directed by you. Ensure you indicate to me when you understand your assigned task. To indicate that you have completed your assigned task return the handout sheet I provided you.

INITIAL CONDITIONS:

A SGTR has occurred coincident with a loss of offsite power and 2ERPO. The CRS has implemented EP/21A15000/E-3 (Steam Generator Tube Rupture). Step 19 is currently in effect to cooldown the NCS.

INITIATING CUES:

The CRS directs you to fully open 2SV-1 (S/G 20 PORV) locally per EP/21A15000/E-3 (Local Operation of S/G PORVs).

This JPM is time critical.

JPM09 J Page 4 of 10 READ TO OPERATOR DIRECTION TO TRAINEE:

I will explain the initial conditions, and state the task to be performed. All control room steps shall be performed for this JPM, including any required communications. I will provide initiating cues and reports on other actions when directed by you. Ensure you indicate to me when you understand your assigned task. To indicate that you have completed your assigned task return the handout sheet I provided you.

INITIAL CONDITIONS:

A SGTR has occurred coincident with a loss of offsite power and 2ERPO. The CRS has implemented EP/2/A/5000/E-3 (Steam Generator Tube Rupture). Step 19 is currently in effect to cooldown the NCS.

INITIATING CUES:

The CRS directs you to fully open 2SV-1 (S/G 20 PORV) locally per EP/2/A/5000/E-3 (Local Operation of S/G PORVs).

This JPM is time critical.

JPM09 J Page 4 of 10

START TIME: __

EXAMINER NOTE:

In the analysis for this event, it has been determined that a maximum of 18 minutes is allowed from the time the NLO is given the procedure in the control room, to the time the valve is fully open. Since 10 minutes were allotted to get to the valve, and 2 minutes are allotted to expose the shaft for manual engagement, the trainee must have 6 minutes left to fully open the valve once the clevis is engaged, and he has demonstrated the proper direction to turn the handwheel to open the valve.

Critical Time starts when the student states he/she is ready to proceed.

TIME CRITICAL START TIME:

STEP 1:

NOTE Emergency flashlights and Merlin-Gerins are available in the control room.

SAT Obtain the following:

o Flashlight o Merlin-Gerin.

UNSAT STANDARD: Obtains flashlight.

EXAMINER CUE: "Flashlight and Merlin-Gerin obtained."

EXAMINER NOTE: This is for outside Doghouse, Merlin Gerin not required.

Emergency Flashlights and Merlin-Gerins are located in the Control Room (SSA desk)

COMMENTS:

JPM09 J Page 5 of 10 STARTTIME: __

EXAMINER NOTE:

In the analysis for this event, it has been determined that a maximum of 18 minutes is allowed from the time the NLO is given the procedure in the control room, to the time the valve is fully open. Since 10 minutes were allotted to get to the valve, and 2 minutes are allotted to expose the shaft for manual engagement, the trainee must have 6 minutes left to fully open the valve once the clevis is engaged, and he has demonstrated the proper direction to turn the handwheel to open the valve.

Critical Time starts when the student states he/she is ready to proceed.

TIME CRITICAL START TIME:

STEP 1:

NOTE Emergency flashlights and Merlin-Gerins are available in the control room.

SAT Obtain the following:

D Flashlight D Merlin-Gerin.

UNSAT STANDARD: Obtains flashlight.

EXAMINER CUE: "Flashlight and Merlin-Gerin obtained."

EXAMINER NOTE: This is for outside Doghouse, Merlin Gerin not required.

Emergency Flashlights and Merlin-Gerins are located in the Control Room (SSA desk)

COMMENTS:

JPM09 J Page 5 of 10

STEP 2:

2. Establish communications with the control room as follows:
a. Obtain sound powered phones from storage on 627' elevation.

- Outside doghouse (DH-627, FF-70, Rm 581)

b. Establish communications from the nearest phone jack at the selected S/G PORV( s):

- Outside doghouse (DH-627, FF-70, Rm 581)

STANDARD: Eastablishes CR communications by locating a sound powered phone and phone jack..

EXAMINER CUE: "Communication has been established with the Control Room."

COMMENTS:

Caution: Severe damage to the actuator assembly can result if operated with the clevis engaged to the actuator shaft and the equalizing valve closed.

Note:

2SV-13 turns counterclockwise to open. 2SV-1, 2SV-7 and 2SV-19 turn clockwise to open.

STANDARD: acknowledges note and caution.

COMMENTS:

STEP 3a:

Place S/G PORV(s) in local operation as follows:

a. Select desired PORV(s):

D 2SV-1 (S/G 20 PORV Manual Ctrl) (DH-635, FF-GG, 69-70, Rm 581 )..

STANDARD: 2SV-1 selected based on initial conditions.

COMMENTS:

JPM09 J SAT UNSAT SAT UNSAT SAT UNSAT Page 6 of 10 STEP 2:

2. Establish communications with the control room as follows:
a. Obtain sound powered phones from storage on 627' elevation.

- Outside doghouse (DH-627, FF-70, Rm 581)

b. Establish communications from the nearest phone jack at the selected S/G PORV( s):

- Outside doghouse (DH-627, FF-70, Rm 581)

STANDARD: Eastablishes CR communications by locating a sound powered phone and phone jack..

EXAMINER CUE: "Communication has been established with the Control Room."

COMMENTS:

Caution: Severe damage to the actuator assembly can result if operated with the clevis engaged to the actuator shaft and the equalizing valve closed.

Note:

2SV-13 turns counterclockwise to open. 2SV-1, 2SV-7 and 2SV-19 turn clockwise to open.

STANDARD: acknowledges note and caution.

COMMENTS:

STEP 3a:

Place S/G PORV(s) in local operation as follows:

a. Select desired PORV( s):

D 2SV-1 (S/G 20 PORV Manual Ctrl) (DH-635, FF-GG, 69-70, Rm 581 )..

STANDARD: 2SV-1 selected based on initial conditions.

COMMENTS:

JPM09 J SAT UNSAT SAT UNSAT SAT UNSAT Page 6 of 10

STEP 3.b:

Unscrew clevis from manual override shaft.

STANDARD: Examinee describes unscrewing clevis from manual override shaft.

EXAMINER CUE: "Clevis has been removed."

COMMENTS:

STEP 3.c:

Turn handwheel in the "close" direction to expose actuator shaft below manual override shaft.

STANDARD: Examinee describes turning the handwheel COUNTERCLOCKWISE to expose actuator shaft below manual override shaft.

EXAMINER CUE: "Actuator shaft has been exposed."

COMMENTS:

STEP 3.d Open equalizing valve on side of PORV actuator.

STANDARD: Examinee locates and describes attaching valve handle to the equalizing valve (on the side of the PORV actuator) and opens the equalizing valve.

EXAMINER CUE: "Equalizing valve is open."

COMMENTS:

JPM09 J CRITICAL STEP SAT

_UNSAT CRITICAL STEP SAT UNSAT CRITICAL STEP SAT

_UNSAT Page 7 of 10 STEP 3.b:

Unscrew clevis from manual override shaft.

STANDARD: Examinee describes unscrewing clevis from manual override shaft.

EXAMINER CUE: "Clevis has been removed."

COMMENTS:

STEP 3.c:

Turn handwheel in the "close" direction to expose actuator shaft below manual override shaft.

STANDARD: Examinee describes turning the handwheel COUNTERCLOCKWISE to expose actuator shaft below manual override shaft.

EXAMINER CUE: "Actuator shaft has been exposed."

COMMENTS:

STEP 3.d Open equalizing valve on side of PORV actuator.

STANDARD: Examinee locates and describes attaching valve handle to the equalizing valve (on the side of the PORV actuator) and opens the equalizing valve.

EXAMINER CUE: "Equalizing valve is open."

COMMENTS:

JPM09 J CRITICAL STEP SAT UNSAT CRITICAL STEP SAT UNSAT CRITICAL STEP SAT

_UNSAT Page 7 of 10

STEP 3.e:

Slide clevis onto actuator shaft.

STANDARD: Examinee describes sliding the clevis onto the exposed actuator shaft.

EXAMINER CUE: "Clevis is secure on the shaft."

COMMENTS:

STEP 3.f Turn handwheel to position valve as desired.

STANDARD: Examinee describes turning handwheel in the CLOCKWISE direction to fully open the valve.

EXAMINER CUE: "Open 2SV-1 to the full open position."

EXAMINER NOTE: The time critical activity ends at this point. Actual time critical activity is 18 minutes but 12 minutes is allotted for this point assuming 6 minutes to fully open the valve.

TIME CRITICAL END TIME: ___

COMMENTS:

JPM09 J CRITICAL STEP SAT UNSAT CRITICAL STEP SAT UNSAT Page 8 of 10 STEP 3.e:

Slide clevis onto actuator shaft.

STANDARD: Examinee describes sliding the clevis onto the exposed actuator shaft.

EXAMINER CUE: "Clevis is secure on the shaft."

COMMENTS:

STEP 3.f Turn handwheel to position valve as desired.

STANDARD: Examinee describes turning handwheel in the CLOCKWISE direction to fully open the valve.

EXAMINER CUE: "Open 2SV-1 to the full open position."

EXAMINER NOTE: The time critical activity ends at this point. Actual time critical activity is 18 minutes but 12 minutes is allotted for this point assuming 6 minutes to fully open the valve.

TIME CRITICAL END TIME: ___

COMMENTS:

JPM09 J CRITICAL STEP SAT UNSAT CRITICAL STEP SAT UNSAT Page 8 of 10

STEP 4 SAT WHEN directed by the control room, THEN restore S/G PORV(s) to control room control as follows:...

STANDARD: Waits for Control Room direction.

UNSAT EXAMINER CUE: "Another operator will return PORV to control room control."

COMMENTS:

This JPM is complete.

TIME STOP: __

JPM09 J Page 9 of 10 STEP 4 SAT WHEN directed by the control room, THEN restore S/G PORV(s) to control room control as follows:...

STANDARD: Waits for Control Room direction.

UNSAT EXAMINER CUE: "Another operator will return PORV to control room controL" COMMENTS:

This JPM is complete.

TIME STOP: __

JPM09 J Page 9 of 10

CANDIDATE CUE SHEET (TO BE RETURNED TO EXAMINER UPON COMPLETION OF TASK)

INITIAL CONDITIONS:

A SGTR has occurred coincident with a loss of offsite power and 2ERPD. The CRS has implemented EP/2/A/5000/E-3 (Steam Generator Tube Rupture). Step 19 is currently in effect to cooldown the NCS.

INITIATING CUES:

The CRS directs you to fully open 2SV-1 (S/G 2D PORV) locally per EP/2/A/5000/E-3 (Local Operation of S/G PORVs).

This JPM is time critical.

CANDIDATE CUE SHEET (TO BE RETURNED TO EXAMINER UPON COMPLETION OF TASK)

INITIAL CONDITIONS:

A SGTR has occurred coincident with a loss of offsite power and 2ERPO. The CRS has implemented EP/2/A/5000/E-3 (Steam Generator Tube Rupture). Step 19 is currently in effect to cooldown the NCS.

INITIATING CUES:

The CRS directs you to fully open 2SV-1 (S/G 20 PORV) locally per EP/2/A/5000/E-3 (Local Operation of S/G PORVs).

This JPM is time critical.

CNS STEAM GENERATOR TUBE RUPTURE EP/21A15000/E-3 - Page 1 of 2 Local Operation of S/G PORVs Emergency flashlights and Merlin-Gerins are available in the control room.

1.

Obtain the following:

_ *

  • Flashlight
  • Merlin-Gerin.

The following are preferred routes to the doghouses:

  • Outside doghouse (2A and 2D S/G) - Through northeast door of Unit 2 turbine building
  • Inside doghouse (2B and 2C S/G) - Through northeast control room exit to the auxiliary building.
2.

Establish communications with the control room as follows:

a. Obtain sound powered phones. from storage on 627' elevation.

_ *

  • Outside doghouse (DH-627, FF-70, Rm 581)

_ ** Inside doghouse (DH-627, FF-61, Rm 562).

PAGE NO.

65 of 110 Revision 32

b. Establish communications from the nearest phone jack at the selected S/G PORV(s):

_ *

  • Outside doghouse (DH-627, FF-70, Rm 581)

_ *

  • Inside doghouse (DH-627, FF-61, Rm 562).

CNS STEAM GENERATOR TUBE RUPTURE EP/2/A15000/E-3 - Page 1 of 2 Local Operation of S/G PORVs Emergency flashlights and Merlin-Gerins are available in the control room.

1.

Obtain the following:

_ ** Flashlight

    • Merlin-Gerin.

The following are preferred routes to the doghouses:

    • Outside doghouse (2A and 2D S/G) - Through northeast door of Unit 2 turbine building
  • *Inside doghouse (2B and 2C S/G) - Through northeast control room exit to the auxiliary building.
2.

Establish communications with the control room as follows:

a. Obtain sound powered phones.from storage on 627' elevation.

_ * *Outside doghouse (DH-627, FF-70, Rm 581)

  • *Inside doghouse (DH-627, FF-61, Rm 562).

PAGE NO.

65 of 110 Revision 32

b. Establish communications from the nearest phone jack at the selected S/G PORV(s):
  • *Outside doghouse (DH-627, FF-70, Rm 581)
  • *Inside doghouse (DH-627, FF-61, Rm 562).

CNS STEAM GENERA TOR TUBE RUPTURE EP/2/A15000/E-3 - Page 2 of 2 Local Operation of S/G PORVs CAUTION Severe damage to the actuator assembly can result if operated with the clevis engaged to the actuator shaft and the equalizing valve closed.

NOTE 2SV-13 turns counter clockwise to open. 2SV-1, 2SV-7 and 2SV-19 turn clockwise to open.

3.

Place S/G PORV(s) in local operation as follows:

a. Select desired PORV(s):

0 o2SV-19 (S/G 2A PORV Manual Control) (DH-635, FF-GG, 70-71, Rm 581) 0 o2SV-13 (S/G 2B PORV Manual Control) (DH-635, FF-GG, 60-61, Rm 562) 0 o2SV-7 (S/G 2C PORV Manual Control) (DH-635, FF-GG, 61-62, Rm 562) 0 o2SV-1 (S/G 2D PORV Manual Control) (DH-635, FF-GG, 69-70, Rm 581).

b. Unscrew clevis from manual override shaft.

PAGE NO.

66 of 110 Revision 32

c. Turn handwheel in the "close" direction to expose actuator shaft below manual override shaft.
d. Open equalizing valve on side of PORV actuator.
e. Slide clevis onto actuator shaft.
f.

Turn handwheel to position valve as desired.

4.

WHEN directed by the control room, THEN restore S/G PORV(s) to control room control as follows:

a. Notify the control room to transmit a closed actuating signal from MCB to the valve positioner.
b. Turn handwheel until the PORV is in the "closed" position and pressure is relieved from the clevis and actuator shaft.
c. Remove clevis from actuator shaft.
d. Turn handwheel until manual override shaft is fully extended.
e. Screw clevis onto manual override shaft.
f.

Close equalizing valve on side of PORV actuator.

CNS STEAM GENERATOR TUBE RUPTURE EP/2/A/5000/E-3 - Page 2 of 2 Local Operation of S/G PORVs CAUTION Severe damage to the actuator assembly can result if operated with the clevis engaged to the actuator shaft and the equalizing valve closed.

NOTE 2SV-13 turns counter clockwise to open. 2SV-1, 2SV-7 and 2SV-19 turn clockwise to open.

3.

Place S/G PORV(s) in local operation as follows:

a. Select desired PORV(s):

0 o2SV-19 (S/G 2A PORV Manual Control) (OH-635, FF-GG, 70-71, Rm 581) 0 o2SV-13 (S/G 2B PORV Manual Control) (OH-635, FF-GG, 60-61, Rm 562) 0 o2SV-7 (S/G 2C PORV Manual Control) (OH-635, FF-GG, 61-62, Rm 562) 00 2SV-1 (S/G 20 PORV Manual Control) (OH-635, FF-GG, 69-70, Rm 581).

b. Unscrew clevis from manual override shaft.

PAGE NO.

66 of 110 Revision 32

c. Turn handwheel in the "close" direction to expose actuator shaft below manual override shaft.
d. Open equalizing valve on side of PORV actuator.
e. Slide clevis onto actuator shaft.
f.

Turn handwheel to position valve as desired.

4.

WHEN directed by the control room, THEN restore S/G PORV(s) to control room control as follows:

a. Notify the control room to transmit a closed actuating signal from MCB to the valve positioner.
b. Turn handwheel until the PORV is in the "closed" position and pressure is relieved from the clevis and actuator shaft.
c. Remove clevis from actuator shaft.
d. Turn handwheel until manual override shaft is fully extended.
e. Screw clevis onto manual override shaft.
f.

Close equalizing valve on side of PORV actuator.

CANDIDATE EXAMINER JPM09 K CATAWBA NUCLEAR STATION INITIAL LICENSE EXAMINATION JOB PERFORMANCE MEASURE JPM09 K Locally Trip the Reactor Page 1 of 7 CANDIDATE EXAMINER JPM09 K CATAWBA NUCLEAR STATION INITIAL LICENSE EXAMINATION JOB PERFORMANCE MEASURE JPM09 K Locally Trip the Reactor Page 1 of 7

Locally Trip the Reactor Alternate Path:

No Facility JPM #:

IPX-016 KIA Rating(s}:

CATAWBA NUCLEAR STATION INITIAL LICENSE EXAMINATION JOB PERFORMANCE MEASURE EPE029 EA1.12 ATWS - MIG set power supply and reactor trip breakers (4.1/4.0)

Task Standard:

At least one Motor or Generator breaker on each train is open isolating all power to the control rod drive system.

Preferred Evaluation Simulator:

Preferred Evaluation Perform Simulator __ _

In-Plant ----'X....!....-_

Perform __

Simulate _~X,--_

References:

EP/1/A/SOOO/FR-S.1 (Response to Nuclear Power Generation/ATWS)

Validation Time: 8 min.

Time Critical: No

=======================================================================

Candidate:

NAME Performance Rating:

SAT ___ UNSAT __ _

Examiner: ----....,.-c--=-------

NAME Time Start: __

Time Finish: __

Question Grade __ _

Performance Time ---


~~~~~ ___ ~/ __ -

SIGNATURE DATE

=======================================================================

COMMENTS JPM09 K Page 2 of 7 Locally Trip the Reactor Alternate Path:

No Facility JPM #:

IPX-016 KIA Rating(s}:

CATAWBA NUCLEAR STATION INITIAL LICENSE EXAMINATION JOB PERFORMANCE MEASURE EPE029 EA1.12 ATWS - MIG set power supply and reactor trip breakers (4.1/4.0)

Task Standard:

At least one Motor or Generator breaker on each train is open isolating all power to the control rod drive system.

Preferred Evaluation Simulator:

Preferred Evaluation Perform Simulator __ _

In-Pia nt ---"X-'--_

Perform __

Simulate _;";X'--_

References:

EP/1/A/SOOO/FR-S.1 (Response to Nuclear Power Generation/ATWS)

Validation Time: 8 min.

Time Critical: No

=======================================================================

Candidate:

Time Start: ___ _

NAME Time Finish: ----

Performance Rating:

SAT ___ UNSAT __ _ Question Grade __ _ Performance Time __ _

Examiner: ____________ _

NAME

~/--~=-

SIGNATURE DATE

=======================================================================

COMMENTS JPM09 K Page 2 of 7

SIMULATOR SETUP SHEET N/A SIMULATOR OPERATOR INSTRUCTIONS:

N/A Tools/Equipment/Procedures Needed:

None JPM09 K Page 3 of 7 SIMULATOR SETUP SHEET N/A SIMULATOR OPERATOR INSTRUCTIONS:

N/A Tools/Equipment/Procedures Needed:

None JPM09 K Page 3 of 7

READ TO OPERATOR DIRECTION TO TRAINEE:

I will explain the initial conditions, and state the task to be performed. All control room steps shall be performed for this JPM, including any required communications. I will provide initiating cues and reports on other actions when directed by you. Ensure you indicate to me when you understand your assigned task. To indicate that you have completed your assigned task return the handout sheet I provided you.

INITIAL CONDITIONS:

Unit 1 was operating at 100% power when the main turbine tripped. The reactor could not be tripped from the control room and the crew entered EP/1/A15000/FR-S.1 (Response to Nuclear Power Generation (ATWS>>.

INITIATING CUES:

The CRS directs you to perform the following:

Reactor Trip breakers Reactor Trip Bypass breakers The following breakers for CRD MIG sets:

o "MOTOR" Breaker o

"GENERATOR" Breaker JPM09 K Page 4 of 7 READ TO OPERATOR DIRECTION TO TRAINEE:

I will explain the initial conditions, and state the task to be performed. All control room steps shall be performed for this JPM, including any required communications. I will provide initiating cues and reports on other actions when directed by you. Ensure you indicate to me when you understand your assigned task. To indicate that you have completed your assigned task return the handout sheet I provided you.

INITIAL CONDITIONS:

Unit 1 was operating at 100% power when the main turbine tripped. The reactor could not be tripped from the control room and the crew entered EP/1/A15000/FR-S.1 (Response to Nuclear Power Generation (ATWS)).

INITIATING CUES:

The CRS directs you to perform the following:

Reactor Trip breakers Reactor Trip Bypass breakers The following breakers for CRD MIG sets:

o "MOTOR" Breaker o

"GENERATOR" Breaker JPM09 K Page 4 of 7

START TIME: __

Open Reactor Trip Breakers.

STANDARD: Depress the RED "TRIP" plate for Reactor Trip Breaker A.

EXAMINER CUE: "1RTA indicates closed."

COMMENTS:

Open Reactor Trip Breakers.

STANDARD: Depress the RED "TRIP" plate for Reactor Trip Breaker B.

EXAMINER CUE: "1 RTB indicates closed."

COMMENTS:

Open the Reactor Trip Bypass Breakers.

STANDARD: Depress the RED "TRIP" plate for Bypass Breaker A.

EXAMINER CUE: "1BYA indicates open."

EXAMINER NOTE: Reactor Trip Bypass Breakers are normally "OPEN".

COMMENTS:

Open the Reactor Trip Bypass Breakers.

STANDARD: Depress the RED "TRIP" plate for Bypass Breaker B.

EXAMINER CUE: "1 BYB indicates open."

EXAMINER NOTE: Reactor Trip Bypass Breakers are normally "OPEN".

COMMENTS:

JPM09 K SAT

_UNSAT SAT UNSAT SAT

_UNSAT SAT

_UNSAT Page 5 of 7 START TIME: __

Open Reactor Trip Breakers.

STANDARD: Depress the RED "TRIP" plate for Reactor Trip Breaker A.

EXAMINER CUE: "1RTA indicates closed."

COMMENTS:

Open Reactor Trip Breakers.

STANDARD: Depress the RED "TRIP" plate for Reactor Trip Breaker B.

EXAMINER CUE: "1RTB indicates closed."

COMMENTS:

Open the Reactor Trip Bypass Breakers.

STANDARD: Depress the RED "TRIP" plate for Bypass Breaker A.

EXAMINER CUE: "1BYA indicates open."

EXAMINER NOTE: Reactor Trip Bypass Breakers are normally "OPEN".

COMMENTS:

Open the Reactor Trip Bypass Breakers.

STANDARD: Depress the RED "TRIP" plate for Bypass Breaker B.

EXAMINER CUE: "1 BYB indicates open."

EXAMINER NOTE: Reactor Trip Bypass Breakers are normally "OPEN".

COMMENTS:

JPM09 K SAT

_UNSAT SAT UNSAT SAT UNSAT SAT

_UNSAT Page 5 of 7

Open the following breakers for CRD MIG sets on 1 MGBA:

o "MOTOR" Breaker o "GENERATOR" Breaker STANDARD: Circuit Breaker Control switch for MG set 1A "MOTOR" breaker and "GENERATOR" breaker is turned to the (left) "TRIP" position and notes GREEN "OPEN" light lit.

EXAMINER CUE:

Read as each breaker is tripped:

"MG Set 1A Motor Breaker has been tripped and the GREEN OPEN light is lit."

"MG Set 1A Gen Breaker has been tripped and the GREEN OPEN light is lit."

EXAMINER NOTE: It is critical that at least one of these two breakers be opened.

COMMENTS:

Open the following breakers for CRD MIG sets on 1 MGBB:

o "MOTOR" Breaker o "GENERATOR" Breaker STANDARD: Circuit Breaker Control switch for MG set 1 B "MOTOR" breaker and "GENERATOR" breaker is turned to the (left) "TRIP" position and notes GREEN "OPEN" light lit.

EXAMINER CUE:

Read as each breaker is tripped:

"MG Set 1B Motor Breaker has been tripped and the GREEN OPEN light is lit."

"MG Set 1 B Gen Breaker has been tripped and the GREEN OPEN light is lit."

EXAMINER NOTE: It is critical that at least one of these two breakers be opened.

COMMENTS:

This JPM is complete.

TIME STOP: __

JPM09 K CRITICAL STEP

_SAT

_UNSAT CRITICAL STEP

_SAT

_UNSAT Page 6 of 7 Open the following breakers for CRD MIG sets on 1 MGBA:

o "MOTOR" Breaker o "GENERATOR" Breaker STANDARD: Circuit Breaker Control switch for MG set 1A "MOTOR" breaker and "GENERATOR" breaker is turned to the (left) "TRIP" position and notes GREEN "OPEN" light lit.

EXAMINER CUE:

Read as each breaker is tripped:

"MG Set 1A Motor Breaker has been tripped and the GREEN OPEN light is lit."

"MG Set 1A Gen Breaker has been tripped and the GREEN OPEN light is lit."

EXAMINER NOTE: It is critical that at least one of these two breakers be opened.

COMMENTS:

Open the following breakers for CRD MIG sets on 1 MGBB:

o "MOTOR" Breaker o "GENERATOR" Breaker STANDARD: Circuit Breaker Control switch for MG set 1 B "MOTOR" breaker and "GENERATOR" breaker is turned to the (left) "TRIP" position and notes GREEN "OPEN" light lit.

EXAMINER CUE:

Read as each breaker is tripped:

"MG Set 1 B Motor Breaker has been tripped and the GREEN OPEN light is lit."

"MG Set 1B Gen Breaker has been tripped and the GREEN OPEN light is lit."

EXAMINER NOTE: It is critical that at least one of these two breakers be opened.

COMMENTS:

This JPM is complete.

TIME STOP: __

JPM09 K CRITICAL STEP SAT UNSAT CRITICAL STEP SAT UNSAT Page 6 of 7

CANDIDATE CUE SHEET (TO BE RETURNED TO EXAMINER UPON COMPLETION OF TASK)

INITIAL CONDITIONS:

Unit 1 was operating at 100% power when the main turbine tripped. The reactor could not be tripped from the control room and the crew entered EP/11A15000/FR-S.1 (Response to Nuclear Power Generation (ATWS>>.

INITIATING CUES:

The CRS directs you to perform the following:

Reactor Trip breakers Reactor Trip Bypass breakers The following breakers for CRD MIG sets:

o "MOTOR" Breaker o

"GENERATOR" Breaker CANDIDATE CUE SHEET (TO BE RETURNED TO EXAMINER UPON COMPLETION OF TASK)

INITIAL CONDITIONS:

Unit 1 was operating at 100% power when the main turbine tripped. The reactor could not be tripped from the control room and the crew entered EP/1/A/SOOO/FR-S.1 (Response to Nuclear Power Generation (ATWS)).

INITIATING CUES:

The CRS directs you to perform the following:

Reactor Trip breakers Reactor Trip Bypass breakers The following breakers for CRD MIG sets:

o "MOTOR" Breaker o

"GENERATOR" Breaker

DUKE POWER CATAWBA OPERATIONS TRAINING Locally Trip the Reactor JOB PERFORMANCE MEASURE

© 2005 Duke Power Each individual JPM packet has been reviewed to contain the following:

Complete JPM - all pages N/A Complete and appropriate procedure/reference document as specified in JPM initial conditions One page (examinee's copy) of JPM initial conditions N/A N/A Prior to JPM session, ensure simulator IC snap that establishes initial conditions for the JPM is accurate and complete N/A N/A Prior to each JPM, ensure simulator setup for the performance of the JPM is verified as accurate as follows:

N/A Appropriate IC selected N/A Test area ready for conduct of JPM Prepared By:

Brett Moore Date:

Reviewed By:

C. T. Kiker, Jr.

Date:

OPS Review:

N/A Date Approved By:

R. E. Kimray Date:

OP-CN-IC-IPX-016 FOR TRAINING PURPOSES ONL Y Page 1 0'4 06/06/05 06/20105 06/22/05 REV. 18 DUKE POWER CATAWBA OPERATIONS TRAINING Locally Trip the Reactor JOB PERFORMANCE MEASURE

© 2005 Duke Power Each individual JPM packet has been reviewed to contain the following:

Complete JPM - all pages N/A Complete and appropriate procedure/reference document as specified in JPM initial conditions One page (examinee's copy) of JPM initial conditions N/A N/A Prior to JPM session, ensure simulator IC snap that establishes initial conditions for the JPM is accurate and complete N/A N/A Prior to each JPM, ensure simulator setup for the performance of the JPM is verified as accurate as follows:

N/A Appropriate IC selected N/A Test area ready for conduct of JPM Prepared By:

Brett Moore Date:

Reviewed By:

C. T. Kiker, Jr.

Date:

OPS Review:

N/A Date Approved By:

R. E. Kimray Date:

OP-CN-IC-IPX-016 FOR TRAINING PURPOSES ONL Y Page 10f4 06/06/05 06/20/05 06/22/05 REV. 18

DUKE POWER CATAWBA OPERA TlONS TRAINING Locally Trip the Reactor Examinee: _________________ _

STANDARD:

Examinee opens both Reactor Trip Breakers, and opens both Control Rod Drive M-G Set Generator and Motor Breakers to shutdown the Reactor.

REFERENCES:

EP/1/A/5000/FR-S.1 (Response to Nuclear Power Generation/ATWS)

INITIATING CUE:

Unit 1 is operating at 100% power when annunciator "LO FLOW P-8 PERM ISS RX TRIP" is received. The OATC observes that "1A" NCP has tripped, but the reactor has failed to trip.

EP/1/A/5000/FR-S.1 (Response to Nuclear Power Generation (ATWS) is in effect. The Control Room Supervisor dispatches you to locally perform the following: Open the Reactor Trip breakers, Reactor Trip Bypass breakers and the following breakers for the CRD MIG Sets: MOTOR breaker and GENERATOR breaker.

EXAMINER SIGNATURE: ____________

DATE: ____

EXAMINER (print): ________________________ _

OP-CN-IC-IPX-016 FOR TRAINING PURPOSES ONL Y Page 2 0'4 REV. 18 DUKE POWER CATAWBA OPERA T/ONS TRAINING Locally Trip the Reactor Examinee: ____________________________________ _

TESTING..

NU2I'iME~T '

PLANT N

STANDARD:

Examinee opens both Reactor Trip Breakers, and opens both Control Rod Drive M-G Set Generator and Motor Breakers to shutdown the Reactor.

REFERENCES:

EP/1/A/5000/FR-S.1 (Response to Nuclear Power Generation/ATWS)

INITIATING CUE:

Unit 1 is operating at 100% power when annunciator "La FLOW P-8 PERM ISS RX TRIP" is received. The OATC observes that "1 A" NCP has tripped, but the reactor has failed to trip.

EP/1/A/5000/FR-S.1 (Response to Nuclear Power Generation (ATWS) is in effect. The Control Room Supervisor dispatches you to locally perform the following: Open the Reactor Trip breakers, Reactor Trip Bypass breakers and the following breakers for the CRD MIG Sets: MOTOR breaker and GENERATOR breaker.

SATISFACTORY UNSATISFACTORY EXAMINER SIGNATURE: ____________

DATE: ____

EXAMINER (print): ________________________ _

OP-CN-IC-IPX-016 FOR TRAINING PURPOSES ONL Y Page 2 0'4 REV. 18

  • 1.
2.
  • 3.

DUKE POWER Open Reactor Trip Breakers Open the Reactor Trip Bypass Breakers Open both Control Rod Drive MIG set Motor and Generator Breakers CATAWBA OPERA TlONS TRAINING Depress the RED "TRIP" plate for Reactor Trip Breaker A and B.

Depress the RED "TRIP" plate for Bypass Breaker A and B.

EXAMINER NOTE: Reactor Trip Bypass Breakers are normally "OPEN".

Circuit Breaker Control switch for each MG set "MOTOR" breaker and each "GENERATOR" breaker are turned to the (left) "TRIP" position. GREEN "OPEN" light lit.

- MG Set 1 A Motor Breaker

- MG Set 1 B Motor Breaker

- MG Set 1A Gen Breaker

- MG Set 1 B Gen Breaker END TIME: ____

OP-CN-IC-IPX-016 FOR TRAINING PURPOSES ONL Y Page 3 of4 REV. 18

  • 1.
2.
  • 3.

DUKE POWER Open Reactor Trip Breakers Open the Reactor Trip Bypass Breakers Open both Control Rod Drive MIG set Motor and Generator Breakers CATAWBA OPERATIONS TRAINING Depress the RED "TRIP" plate for Reactor Trip Breaker A and B.

Depress the RED "TRIP" plate for Bypass Breaker A and B.

EXAMINER NOTE: Reactor Trip Bypass Breakers are normally "OPEN".

Circuit Breaker Control switch for each MG set "MOTOR" breaker and each "GENERATOR" breaker are turned to the (left) "TRIP" position. GREEN "OPEN" light lit.

- MG Set 1 A Motor Breaker

- MG Set 1 B Motor Breaker

- MG Set 1 A Gen Breaker

- MG Set 1 B Gen Breaker END TIME: ____

OP-CN-IC-IPX-016 FOR TRAINING PURPOSES ONL Y Page 3 of4 REV. 18

DUKE POWER CATAWBA OPERA TlONS TRAINING INITIATING CUE:

Unit 1 is operating at 100% power when annunciator "LO FLOW P-8 PERM ISS RX TRIP" is received. The OATC observes that "1A" NCP has tripped, but the reactor has failed to trip.

EP/1/A/SOOO/FR-S.1 (Response to Nuclear Power Generation (ATWS) is in effect. The Control Room Supervisor dispatches you to locally perform the following: Open the Reactor Trip breakers, Reactor Trip Bypass breakers and the following breakers for the CRD MIG Sets: MOTOR breaker and GENERATOR breaker.

OP-CN-IC-IPX-016 FOR TRAINING PURPOSES ONL Y Page 4 of4 REV.1B DUKE POWER CATAWBA OPERATIONS TRAINING INITIATING CUE:

Unit 1 is operating at 100% power when annunciator "LO FLOW P-8 PERMISS RX TRIP" is received. The OATC observes that "1A" NCP has tripped, but the reactor has failed to trip.

EP/1/A/SOOO/FR-S.1 (Response to Nuclear Power Generation (ATWS) is in effect. The Control Room Supervisor dispatches you to locally perform the following: Open the Reactor Trip breakers, Reactor Trip Bypass breakers and the following breakers for the CRD MIG Sets: MOTOR breaker and GENERATOR breaker.

OP-CN-IC-IPX-016 FOR TRAINING PURPOSES ONL Y Page 4 of4 REV.1B