JSOUTHERN CALIFORNIA EDISON" An EDISON INTERNATIONAL Company James T. Reilly Vice President July 11, 2008 U. S. Nuclear Regulatory Commission Attention: Document Control Desk Washington, D. C. 20555

Subject:

Docket No. 50-206 10 CFR 50.71(e)

Defueled Safety Analysis Report San Onofre Nuclear Generating Station Unit I Gentlemen:

In accordance with the requirements of 10 CFR 50.71(e), Southern California Edison (SCE) hereby submits the amended Defueled Safety Analysis Report (DSAR) for San Onofre Nuclear Generating Station Unit 1 (SONGS 1). In accordance with "Guidance for Electronic Submissions to the NRC," Revision 3, November 20, 2007, SCE is providing this amendment on the enclosed CD-ROM.

The entire submittal is publicly available, containing no proprietary, personal, or safeguards information. The enclosed CD-ROM contains the files listed in.

Should there be any questions as to in this submittal, please contact Ms. Linda Conklin at (949) 368-9443.

There are no regulatory commitments made in this letter.

P.O. Box 128 San Clemente, CA 92674-0128 949-368-3780 Fax 949-368-3770 Ao53 AMe(

Document Control Desk July 11, 2008 I declare under penalty of perjury that the foregoing is true and correct.

Executed on (Date)

Enclosures (1) SONGS Unit 1 DSAR CD-ROM (2) List of files on Enclosure 1 cc:

E. E. Collins, Regional Administrator, NRC Region IV J. C. Shepherd, NRC Project Manager, SONGS 1 G. G. Warnick, NRC Senior Resident Inspector, San Onofre Units 2 & 3

ENCLOSURE 2 List of files on Enclosure I SONGS Unit I DSAR CD-ROM

List of files on Enclosure 1 SONGS Unit 1 DSAR CD-ROM Directory Filename Filesize autorun.ico 2,734 AUTORUN.inf 56 autorun.txt 57 DSAR.html 18,025 Launch.exe 28,672 Readme.txt 863 songs bg. gif 41,952

\\DSAR 000 NRC Amendment for Section 1.pdf 409,843 001 NRC Amendment for Section 2.pdf 531,405 002 NRC Amendment for Section 3.pdf 620,718 003 NRC Amendment for Section 4.pdf 592,595 004 NRC Amendment for Section 5.pdf 89,039 005 NRC Amendment for Section 6.pdf 122,574 006 NRC Amendment for Section 7.pdf 43,357 007 NRC Amendment for Section 8.pdf 72,289 009 NRC Amendment for Appendix B.pdf 57,356 010 NRC Amendment for PDF Report Appendix A.pdf 710,729 011 NRC Amendment for PDF Report Contents.PDF 67,778

\\DSAR\\Compendium 00008XNI.pdf 875,688 00008XNM.pdf 1,256,457 00008XNO.pdf 957,124 00008XNQ.pdf 1,033,564 00008XNR.pdf 731,413 OOOOKEU4.pdf 740,825 OOOOKEU5.pdf 864,272 OOOOKEUY.pdf 472,557 000OP4EF.pdf 993,093 000OS2JD.pdf 716,059 0000WXSR.pdf 723,364 000OZ8DI.pdf 713,263 OOOOZLQ7.pdf 525,316 OOOOZSMT.pdf 415,123 OOOOZSMU.pdf 470,003 0001 OOLY.pdf 588,729 0001141V.pdf 555,238 0001366M.pdf 592,090 1 of 2

. List of files on Enclosure 1 SONGS Unit 1 DSAR CD-ROM Directory Filename Filesize 00013QLC.pdf 430,412 0001412Z.pdf 431,094 00014VNW.pdf 728,016 00015DOQ.pdf 549,985 000 15DUN.pdf 752,970 00015EBZ.pdf 432,501 0001 5XVE.pdf 757,857 0001 6ETK.pdf 610,185 0001 7OMR.pdf 439,754 0001 7P9F.pdf 681,314 000192PW.pdf 647,535 0001 9LEE.pdf 412,662 0001AAJ4.pdf 502,567 0001AEYQ.pdf 420,161 0001COSN.pdf 601,130 0001CRK3.pdf 567,160 000lCSN5.pdf 585,820 0001 CXOT.pdf 583,176 0001D5XU.pdf 558,566 0001DC 1G.pdf 587,172 0001 GFTC.pdf 379,519 0001 GJQY.pdf 648,854 0001GWLB.pdf 569,817 40028R4.pdf 939,207 A48607.pdf 729,517 2 of 2

San Onofre Unit I DSAR INTRODUCTION

1.0 INTRODUCTION

1.1 EXECUTIVE

SUMMARY

San Onofre Unit I (SONGS 1) commercially generated power from January 1, 1968 until November 30, 1992. SONGS 1 was permanently defueled on March 6, 1993 and was maintained in SAFSTOR until June 1999, when the Decommissioning program was initiated.

This Defueled Safety Analysis Report (DSAR) was prepared in response to the requirements of 10 CFR 50.71(e)(4):

"For nuclear power reactor facilities that have submitted the certifications required by 50.82(a)(1), subsequent revisions must be filed every 24 months."

The NRC provided guidance in Regulatory Guide 1.184, Decommissioning of Nuclear Power Reactors, for updating the Final Safety Analysis Report (FSAR) of a permanently shutdown facility. Section 8.2, "Maintenance of the Final Safety Analysis Report", identifies those sections which should continue to be updated periodically. Those sections were used in the preparation of the DSAR. The information provided in the specific sections of the DSAR was taken from various design and Licensing basis documents including the Unit I UFSAR, Unit I UFHA, Post Shutdown Decommissioning Activities Report (PSDAR), and the Permanently Defueled Technical Specifications (PDTS).

The SONGS I DSAR provides an updated Licensing Basis for the defueled condition and for Decommissioning activities.

1.1.1 ORGANIZATION OF THE DEFUELED SAFETY ANALYSIS REPORT The SONGS 1 DSAR is organized into the following main sections:

INTRODUCTION SITE CHARACTERISTICS FACILITY DESCRIPTION Facility Description Fuel Storage Facility Sphere Reactor Auxiliary Building Intake Structure Turbine Building Electrical System Monitoring and Communications Fire Protection LICENSEE ORGANIZATION AND CONDUCT OF OPERATIONS RADIOACTIVE WASTE MANAGEMENT RADIATION PROTECTION ACCIDENT ANALYSIS 1-1 Amended: June 2008 TL:

San Onofre Unit 1 DSAR INTRODUCTION 1.

1.2 BACKGROUND

SONGS 1 is currently defueled with the spent fuel transferred to-the Independent Spent Fuel Storage Installation (ISFSI). The Decommissioning Project is proceeding to dismantle and decontaminate the plant to levels that will permit release for unrestricted use.

The SONGS 1 UFSAR was prepared for the operating plant license and written to comply with the applicable regulatory requirements. The UFSAR was organized around the performance of the fuel, the reactor, the reactor coolant system, and the associated support and safety systems.

The DSAR, which replaces the UFSAR, was created to describe the plant and to present its licensing basis during the decommissioning process. Many of the topics and analysis discussed in the UFSAR, particularly those concerned with the adequacy for power operation, do not apply to decommissioning. The process of eliminating inapplicable information began with the original DSAR and has been carried forth by the subsequent revisions. The information that remains is focused on providing an initial condition for the 50.59 evaluations of dismantlement and demolition activities.

1.1.3 ADMINISTRATIVE SECTIONS The administrative sections: Licensee Organization, Conduct of Operations, Radiation Protection, and Radioactive Waste Management, are similar to those sections in the UFSAR, updated for Decommissioning.

1.2 SITE DESCRIPTION San Onofre Nuclear Generating Station, Unit 1 (SONGS 1) is part of a three unit station located on the coast of Southern California, in San Diego County. The site is located entirely within the Camp Pendleton Marine Corps Base under an easement granted by the United States Government. Unit I is northwest of, and adjacent to, Units 2 and 3. Figure 1-1 shows the general location of the station.

SONGS 1 is jointly owned by Southern California Edison Company (SCE) and San Diego Gas and Electric Company (SDG&E). SCE is the primary owner and operator of the station. The use of the property on which the three SONGS units are built was granted to SCE and SDG&E until May 12, 2024. Unit 1 went critical on June 14, 1967 and entered commercial operation on January 1, 1968. As a result of an agreement with the California Public Utilities Commission (CPUC), operation of SONGS 1 was permanently discontinued on November 30, 1992, at the end of Fuel Cycle No. 11. The reactor was defueled and maintained in SAFSTOR until June 1999. All spent fuel was transferred from the Unit 1 spent fuel pool to the ISFSI as of August 31, 2004. SONGS 1 is currently being dismantled and demolished in accordance with Decommissioning Program requirements.

The station site is located in a sparsely populated area. It is surrounded principally by unused land due to the natural exclusion provided by the Marine Corps reservation. The topography surrounding the site consists of a gently sloping coastal plain, terminated abruptly at the shoreline by high sea cliffs. Excavation of the bluff at the shoreline has provided a foundation for the station of extremely dense sand. From seismic, geologic, and foundation considerations, 1-2 Amended: June 2008 TL:

San Onofre Unit I DSAR INTRODUCTION this formation is adequate to support the structural loads. The site enjoys favorable meteorological conditions, except for relatively few occasions, with daily land and sea breezes.

Investigations in meteorology, oceanography, and environmental monitoring have been conducted to verify the environmental characteristics of the site.

1.3 FACILITY DESCRIPTION Three nuclear generating units and supporting facilities are located on the SONGS site. Figure 2-1 shows the original layout of the SONGS Site Plan. SONGS 1 was comprised of a Westinghouse three-loop, 450 MWe Nuclear Steam Supply System (NSSS) and turbine-generator. All spent fuel has been removed from the reactor and transferred to the ISFSI.

The major structures on the SONGS 1 portion of the site were the: Containment Sphere Turbine Building, Fuel Storage Facility, Reactor Auxiliary Building, and the Intake and Discharge Structure. These structures and their foundations have been removed or abandoned as described in Facility Description sections. The decommissioned general arrangement is shown on drawing 40028.

1.4 REGULATORY HISTORY & MAJOR PROJECTS SONGS I operation was authorized by a Provisional Operating License issued on March 27, 1967, by the NRC's predecessor, the Atomic Energy Commission (AEC). Initial criticality was achieved on June 14, 1967, and SONGS 1 began commercial operation on January 1, 1968. The Environmental Report and the Final Environmental Statement (FES) were issued in accordance with applicable regulations implementing the requirements of the National Environmental Policy Act of 1969.

On July 28, 1970, following two extensions to the Provisional Operating License, SCE submitted an application to convert the Provisional Operating License to a Full-Term Operating License (FTOL or simply the "Operating License"). In connection with this application, SCE provided, in February, 1986, and August, 1991, updated information relevant to the findings and conclusions contained in the FES. Based on the updated information, the NRC issued an Environmental Assessment in September, 1991, which updated the FES. This was followed by issuance of the Facility Operating License (OL) on September 26, 1991. The license authorized SONGS 1 operation until March 2, 2004, 40 years after the date of issuance of the Construction Permit.

The long delay (from July, 1970, to September, 1991) in issuing the OL was caused by the NRC (and AEC) re-evaluation of the SONGS 1 design in light of industry operating experience and the updated design standards which were established after the plant was constructed. SONGS 1 operated under a Provisional Operating License since March 27, 1967, as authorized by 10 CFR 2.109, until the OL was issued.

SONGS 1 was permanently shut down on November 30, 1992, at the end of Fuel Cycle No. 11.

On April 2, 1992, SCE submitted an application to the NRC to modify the OL to an Operating (Possession Only) License (POL). The NRC issued the license amendment on October 23, 1992.

The POL became effective on March 9, 1993, after SCE provided certification that operation of 1-3 Amended: June 2008 TL:

San Onofre Unit 1 DSAR INTRODUCTION the reactor had been permanently terminated and all fuel from the SONGS 1 core was stored in the plant's spent fuel pool.

The SONGS 1 Post-Shutdown Decommissioning Activities Report (PSDAR) outlines the planned Decommissioning process. SCE originally intended to decommission SONGS 1 along with Units 2 and 3, at the end of their licenses (2013). The NRC was subsequently advised in the PSDAR, dated December 15, 1998, that SCE intended to start Decommissioning in June 1999, a significantly earlier date than that indicated previously.

1.5 DECOMMISSIONING STATUS As described in the Post Shutdown Decommissioning Activities Report, SONGS 1 is undergoing active decommissioning to return the site to a condition suitable for unrestricted use. All systems, structures and components and their foundations have been removed or abandoned as described in Section 3. The remaining decommissioning activity in progress is soil remediation, compaction and grading.

1.6 DSAR BASIS AND DESCRIPTION The SONGS 1 DSAR provides an updated Licensing Basis for the defueled condition and for Decommissioning activities.

Operations at SONGS 1 are controlled under the Permanently Defueled Technical Specifications (PDTS), issued by Amendment No. 155 dated December 28, 1993, and modified by subsequent amendments, and by the SONGS 1 operating procedures. Decommissioning activities, dismantlement, demolition and decontamination, are performed under applicable site-wide programs and SCE design control processes, including processes developed specifically for controlling the removal of abandoned equipment.

The DSAR format was chosen to simplify the preparation of 50.59 evaluations for dismantlement of the facility and the completion of the Decommissioning process. The dismantlement is proceeding by removing systems and components in an order determined by their location rather than by system function and operation. The descriptions of plant equipment and Decommissioning activities are organized by their location within the facility, rather than by system.

Many of the topics and analyses discussed in the UFSAR, particularly those that demonstrate the technical adequacy for power operation, do not apply to Decommissioning. The Facility Description sections have been revised to retain information that might be useful for preparing dismantlement 50.59 evaluations under the 50.59 process, while eliminating obsolete information.

The Facility Description sections contain a description of the major systems and components that are still in service, physical descriptions of major abandoned components, and design evaluations addressing the interactions between the plant components and Decommissioning activities.

The descriptions provided for components which no longer are important to safety are intended to aid in understanding the past use of the components and identifying possible safety hazards 1-4 Amended: June 2008 TL:

San Onofre Unit 1 DSAR INTRODUCTION during dismantlement. Therefore, no additional attention was given to verifying the design information for these components.

1.6.1 DELETED 1.6.2 DELETED 1.6.3 DELETED 1.6.4 DELETED 1.6.5 DELETED 1.6.6 DELETED 1.6.7 DELETED 1.7 DELETED 1.8 IDENTIFICATION OF AGENTS AND CONTRACTORS 1.8.1 OWNERS OF THE FACILITY AND HOLDERS OF THE OPERATING LICENSE Sole owners of the facility and holders of the Possession Only License (POL) are:

Southern California Edison Company (SCE), and San Diego Gas and Electric Company (SDG&E).

1.8.2 PROJECT MANAGER SCE is the manager for the Decommissioning Project and is responsible for the technical adequacy of the design, modification, operation, and demolition activities at Unit 1.

1.8.3 DELETED

1.9 REFERENCES

1.

Letter, J. 0. Bradfute, U. S. Nuclear Regulatory Commission, to H. B. Ray, SCE, "Issuance of Amendment for the San Onofre Nuclear Generating Station, Unit No. 1 (TAC NO.

M83123)," dated October 23, 1992

2.

Letter, H. B. Ray, SCE, to Document Control Desk, U.S. Nuclear Regulatory Commission, "Amendment Application No. 211, Permanently Defueled Technical Specifications, San Onofre Nuclear Generating Station, SONGS 1," dated May 12, 1993 1-5 Amended: June 2008 TL:

San Onofre Unit I DSAR INTRODUCTION

3.

Letter, H. B. Ray, SCE, to Document Control Desk, U.S. Nuclear Regulatory Commission, "Amendment Application No. 203, San Onofre Nuclear Generating Station, SONGS I," dated April 2, 1992

4.

Letter, R. M. Rosenblum, SCE, to Document Control Desk, U.S. Nuclear Regulatory Commission, "Operation and Surveillance Requirements for Permanently Defueled Condition for San Onofre Nuclear Generating Station, SONGS 1," dated September 21, 1992

5.

Letter, W. C. Marsh, SCE, to Document Control Desk, U.S. Nuclear Regulatory Commission, "Implementation Schedule for Operation and Surveillance Requirements for the Permanently Defueled Condition, San Onofre Nuclear Generating Station, SONGS 1," dated March 3, 1993

6.

Letter, W. C. Marsh, SCE, to Document Control Desk, U.S. Nuclear Regulatory Commission, "Preliminary Decommissioning Plan, San Onofre Nuclear Generating Station, SONGS 1," dated December 1, 1992

7.

Letter, Michael K. Webb (NRC), to Harold B. Ray (SCE), "Issuance of Amendment No.

155 to Facility Operating License No. DPR-13, San Onofre Nuclear Generating Station Unit, No.

1, Permanently Defueled Technical Specifications (TAC No. M86377)," December 28, 1993

8.

Physical Security Plan, San Onofre Nuclear Generating Station Units 1, 2, and 3, Southern California Edison (Safeguards Information Withheld from Public Disclosure in Accordance with 10CFR73.2 1)

9.

Post Shutdown Decommissioning Activities Report (PSDAR) for SONGS 1, December 15, 1998

10.

"San Onofre Generating Station Unit 1, Updated Final Safety and Analysis Report,"

Docket 50-206

11.

Regulatory Guide 1.184, Decommissioning of Nuclear Power Reactors, dated June 1997

12.

Letter, Drew Holland (U.S. Nuclear Regulatory Commission) to H. B. Ray (SCE), "Spent Fuel Pool Plant Conditions During Decommissioning, San Onofre Nuclear Generating Station, SONGS 1, (TAC No. MB0405, Amendment Application No. 217)," dated October 30, 2001 (NRC Amendment No. 160)

13.

"Permanently Defueled Technical Specifications," Amendment No. 155 to License No.

DPR-13, Issued December 28, 1993

14.

"Permanently Defueled Technical Specifications," Amendment No. 163 to License No.

DPR-13, Issued September 22, 2004 1-6 Amended: June 2008 TL:

n Bc

/Son eernardeno Co.

RO iverside IrI Son Bego Diego

-/"

OceansiderideCO Esondido So-Deg (2r 5

0 20 "PROXIMAE SCALE IN -LES SAN ONOFRE NUCLEAR GENERATING STATION Unit 1 Defueled Safety Analysis Report General Site Area Figure 1-1 Amended: June 2008 TL:

SONGS Unit I DSAR Figure. 1-2 North Industrial Area General..Arangement See Drawing 40028 Amended: June 2008 TL:

San Onofre Unit I DSAR SITE CHARACTERISTICS 2.0 SITE CHARACTERISTICS This section describes the San Onofre site, and the location of the SONGS 1 facility.

Descriptions are provided of the site characteristics, geography and demographics, the exclusion area, low population zone, and development of the atmospheric dispersion factors.

Hydrological, meteorological and some population data have been moved to Appendix A, Historical Information. This information and its impact to the facility design is not expected to change during Decommissioning (through license termination).

Changes to the Site Characteristics section are no longer required.

2.1 GEOGRAPHY AND DEMOGRAPHY 2.1.1 SITE LOCATION AND DESCRIPTION 2.1.1.1 Specification of Location The SONGS site is located on the coast of Southern California in San Diego County, approximately 62 miles southeast of Los Angeles and 51 miles northwest of San Diego. The site is located entirely within the boundaries of the United States Marine Corps Base, Camp Pendleton, California, near the northeast end of its 18-mile shoreline.

The coordinates for SONGS 1 are latitude 33'22'10" N and longitude 117'33'30"W.

2.1.1.2 Site Area Map The plant property line, which is also the site boundary, and the location of the original major structures of the facilities are delineated in Figure 2-1. The site, comprising 83.63 acres, is about 4500 feet long and 800 feet wide. The SONGS 1 power block waslocated northwest of Units 2 and 3, occupies 11.7 acres. The SONGS 2 and 3 power block occupies 19.5 acres. A spur of The Burlington Northern and Santa Fe Railway line extends into the site area.

The SONGS site exclusion area is a common area for SONGS 1, 2, and 3 and is roughly formed by two semicircles with radii of 1967.5 feet each, centered on the SONGS 2 containment and a point 134 feet southwest of the SONGS 3 containment. The minimum exclusion area distance for SONGS 1 is 996 feet (282 meters) measured from the center of Unit 1 containment northwestward to the nearest point on the exclusion area boundary. The exclusion area boundary is delineated in Figure 2-2. At the northwest and southeast site boundaries, the exclusion area is tangential to, but does not exceed, the site boundary. There are no industrial, commercial, institutional, or residential structures within the exclusion area boundary.

2-1 Amended: June 2008 TL:

San Onofre Unit 1 DSAR SITE CHARACTERISTICS The Pacific Ocean is located immediately west of the site and traverses the seaward side of the exclusion area. The San Onofre State Beach includes sections of the coast on both sides of the site. Access to open beach areas up and down the coast from the exclusion area is provided by a walkway (the beach passageway) adjacent to the SONGS 1, 2, and 3 seawall. The passageway extends the 2200-foot length of the seawall and is bounded on the seaward side by a concrete wall extending approximately three (3) feet above the passageway surface.

A typical cross-section through the beach passageway is shown in Figure 2-3. The passageway is 15 feet in total width with a hard surface which can accommodate pedestrian traffic only Two removable vehicle barriers are installed along the beach passageway (one at the northwest comer of Unit 2 boundary and another at the southwest comer of Unit 3 boundary) as part of SONGS security enhancements following NRC's order.issued on April 29, 2003 to upgrade the plant's security. A 3-foot wide, 20-foot long removable pedestrian bridge is also installed along the passageway at the intake structure area of Units 2 and 3 to permit pedestrian access when the saltwater cooling system of Units 2 and 3 is discharging to the beach, during which the passageway will be flooded.. The seaward side of the walkway is formed by a concrete retaining wall which is protected by riprap in the event of infrequent beach erosion caused by wave action.

Old Highway 101 is immediately adjacent to the east boundary line of the site. The highway is currently being used for access the south end of the State Beach. The Burlington Northern and Santa Fe Railway right of way is east of Highway 101. Interstate Highway 5 is adjacent to the railroad right of way.

2.1.1.3 Boundaries for Establishing Effluent Release Limits The site-restricted area defined for the purpose of establishing effluent release limits coincides with the exclusion area boundary as shown in Figure 2-2. The procedures for control of individual access and a description of the boundary are presented in Section 2.1.2.

The Unit 1 Offsite Dose Calculation Manual describes the administrative controls and calculation methodology applied to maintain effluent releases within regulatory limits.

2.1.2 EXCLUSION AREA AUTHORITY AND CONTROL 2.1.2.1 Authority The applicant's authority to control all activities within the exclusion area was acquired by grant of easement from the United States of America made by the Secretary of the Navy pursuant to the authority of Public Law 88-82. This easement is recorded in the official records of the Recorder of San Diego County, California, on page 85887, Series 5, Book 1964.

In order to remove any ambiguities contained in the original grant of easement with respect to the applicant's authority to control activities in the exclusion area, an amendment to the grant of easement was executed on September 18, 1975, and is reproduced below, in part:

"In order to protect the public health and safety, and in accordance with the rules, regulations and requirements of the United States Nuclear Regulatory Commission, 2-2 Amended: June 2008 'TL:

San Onofre Unit 1 DSAR SITE CHARACTERISTICS successor to the United States Atomic Energy Commission, applicable to the Nuclear Station, the Grantees may determine all activities including exclusion or removal of personnel and property from such exclusion area as is established from time to time by or with the approval of the United States Nuclear Regulatory Commission and is located within the lands described in Exhibit B. Subject to the foregoing, such exclusion area may be used by the Government, its successor or assigns, for military operations (provided same do not endanger operation of the Nuclear Station), agricultural, recreational and such other uses as may be compatible with operation of the Nuclear Station, provided that any and all uses of the exclusion area shall be in accordance with and subject to the rules, regulations and requirements of the United States Nuclear Regulatory Commission applicable to the Nuclear Station, and further provided that no significant hazards to the public health and safety shall result from any such uses."

This amendment to the grant of easement expires on May 12, 2024.

All mineral rights in the land portion of the exclusion area are held by the United States Government.

The Pacific Ocean, Interstate Highway 5 (San Diego Freeway), old U.S. Highway 101, The Burlington Northern and Santa Fe Railway right-of-way, and the beach passageway constitute traverses of the site exclusion area as allowed by 10CFR100.3(a).

2.1.2.2 Control of Activities Unrelated to Plant Operation Recreational activities, such as sunbathing or picnicking, are not permitted within the landward portion of the exclusion area (the area landward of the contour of mean high tide). The seaward portion of the exclusion area (the area seaward of the contour of mean high tide) may be occupied by small numbers of people for passageway transit between the public beach areas upcoast and downcoast from the plant. Additional small numbers of people may be anticipated to occasionally be in the water.

Transient access to an approximately 5-acre area at the southwest comer of the site for the purposes of viewing the scenic bluffs and barrancas will be on an unimproved walkway. The improved walkway affords landward passage between the two beach areas.

Physical features and administrative controls are planned to control activities in the landward portion of the exclusion area. These features and controls will have the effect of minimizing use of the seaward portion so that it will be predominately passageway use.

The following enforcement measures are planned in order to ensure that use of the beach exclusion area, not related to operation of the facility, will be minimized and will be predominantly passageway transit:

A.

Beach areas within the exclusion area will be subject to periodic surveillance by direct means.

2-3 Amended: June 2008 TL:

San Onofre Unit 1 DSAR SITE CHARACTERISTICS B.

If use of beach areas within the exclusion area is observed to be other than for transient use, an announcement may be made over the public address system, or other means, to request the movement of persons out of the exclusion area.

C.

Should actions described above prove to be unsuccessful, plant security personnel will request the assistance of the California State Park Rangers or Camp Pendleton Military Police.

2.1.2.3 Arrangements for Traffic Control The environs of the Site are the Pacific Ocean and the beach passageway on the west, the San Diego Freeway (Interstate 5), old U.S. Highway 101, and the Burlington Northern and Santa Fe railroad on the southeast and north.

In the event of an emergency, all traffic within the roadways and waterways is subject to control by agencies of state and local governments. Surveillance measures discussed in paragraph 2.1.2.2 will control the use of the beach passageway.

Detailed information concerning the arrangements for control of traffic within the exclusion area traverse zones is presented in the SONGS emergency plan.i' 2.1.2.4 Abandonment or Relocation of Roads There are no public roads that were subject to abandonment or relocation as a result of construction of SONGS 1, 2, and 3.

2.1.3 LOW POPULATION ZONE The low population zone (LPZ) is the area contained within 1.95 miles of the plant site. This distance is established to ensure that the guidelines of 10CFR100 are met with respect to the LPZ and the population center. The LPZ is shown in Figure 2-4 along with transportation routes that may be used by Marine Corps personnel for evacuation purposes.

Population estimates are included in Appendix A, Historical Information.

2.

1.4 REFERENCES

1.

Southern California Edison Company, Emergency Plan for San Onofre Nuclear Generation Station Units 1, 2, and 3

2.

"San Onofre Generating Station Unit 1, Updated Final Safety and Analysis Report,"

Docket 50-206 2-4 Amended: June 2008 TL:

San Onofre Unit 1 DSAR SITE CHARACTERISTICS 2.2 HYDROLOGY AND METEOROLOGY The hydrological and meteorological data and information developed and verified for the SONGS site are included in Appendix A, Historical Information. A general review has determined that this information, its basis, and its impact to the facility design will not change during Decommissioning (through license termination).

2.3 SHORT-TERM (ACCIDENT) DIFFUSION ESTIMATES The atmospheric dispersion factors used for the operating plant license, were calculated as part of the Nuclear Regulatory Commission safety evaluation report of SEP Topic II-2.C.(3) using the direction-dependent method described in Regulatory Guide 1.145, "Atmospheric Dispersion Models for Potential Accident Consequence Assessments at Nuclear Power Plants."(3) This model incorporates the results of recent atmospheric tracer tests and considers the directionally dependent atmospheric dispersion conditions.(4)

Specifically, the modified dispersion model considers the following effects:

(1)

Lateral plume meander, as a function of atmospheric stability, wind speed, and distance from the source, during periods of low wind speeds (< 6m/s) and neutral and stable atmospheric conditions; (2)

Exclusion area boundary distance as a function of direction from the plant; (3)

Atmospheric dispersion conditions when the wind is blowing in a specific direction; and (4)

The fraction of time that the wind can be expected to blow into each of the 16 compass directions.

The evaluation included meteorological data collected at the SONGS site for 3 years, January 25, 1973 to January 24, 1976. Wind direction and speed were measured at the 10-meter level, and estimates of atmospheric stability were based on vertical temperature differences.

Short term x/Q values for a ground level release have been computed for various time intervals at the exclusion area boundary (EAB), varying over land from 282 to 1046 meters, and the outer boundary of the low population zone (LPZ), a circle with a radius of 2898 meters. A building wake factor of 3 was used in the analysis based on a cross sectional area of 1000 square meters.

The estimated zero - 2 hour2.314815e-5 days <br />5.555556e-4 hours <br />3.306878e-6 weeks <br />7.61e-7 months <br /> X/Q values will be exceeded on the average no more than 44 hours5.092593e-4 days <br />0.0122 hours <br />7.275132e-5 weeks <br />1.6742e-5 months <br /> a year (0.5% of the total time) and were calculated at the EAB and LPZ for SONGS 1 for each sector. Of the onshore sectors, the northwest downwind sector was found to have the highest x/Q values at both the EAB and LPZ. These values are used in the evaluation of short-term accidental releases and are listed in Table 2.1. (x/Q values for some over-water sectors at both the EAB and LPZ, which were excluded from the analysis, are greater than the maximum onshore sector values.) The x/Q values that were appropriate for estimating exposures from 2-5 Amended: June 2008 TL:

San Onofre Unit 1 DSAR SITE CHARACTERISTICS postulated accidents under the operating license are included in Appendix A, Historical Information in Table A2.7-4.

TABLE 2-1 SHORT-TERM RELATIVE DISPERSION VALUES APPLICABLE FOR ACCIDENT ANALYSES Time Period Location x/Q (s/mr3) 0 - 2 hours2.314815e-5 days <br />5.555556e-4 hours <br />3.306878e-6 weeks <br />7.61e-7 months <br /> EAB 9.5 x 10-4 0 - 8 hours9.259259e-5 days <br />0.00222 hours <br />1.322751e-5 weeks <br />3.044e-6 months <br /> LPZ 2.7 x 10-5 8 - 24 hours2.777778e-4 days <br />0.00667 hours <br />3.968254e-5 weeks <br />9.132e-6 months <br /> LPZ 1.9 x 10-1 1 - 4 days LPZ 8.2 x 10-6 4 - 30 days LPZ 2.7 x 10-6 2.4 BIBLIOGRAPHY

1.

Updated Final Safety Analysis Report, San Onofre Nuclear Generating Station, Unit 2 &

3, Southern California Edison Company, Dockets 50-361, 50-362.

2.

U.S. Nuclear Regulatory Commission: Safety Evaluation Supporting Amendment No. 25 to Preliminary/Operating License No. DPR-13, Final Evaluation of Atmospheric Transport and Diffusion Characteristics for Accident Analysis - San Onofre (SEP Topic II-2.C), November 18, 1981.

3.

J.I.P. Jones and F. Pasquill, "An Experimental System for Directly Recording Statistics of the Intensity of Atmospheric Turbulence," Quarterly Journal Royal Meteorology Society, 85, 365, pp. 225-236, (1959).

4.

M. Septoff, A. E. Mitchell, and L. H. Teuscher, Final Report of the Onshore Tracer Tests Conducted December 1976 Through March 1977 at the San Onofre Nuclear Generating Station. NUS-1927, NUS Corporation, Rockville, Maryland, (1977).

2-6 Amended: June 2008 TL:

Central Processing Health Physics Building /

' Rad Waste Admin.

Maintenance Building and Processing Building Spent Fuel Building Reactor Admin. Building NOTE:

The Site Plan for the operating plant is shown for reference and does not include changes made for Decommissioning.

SAN ONOFRE NUCLEAR GENERATING STATION Unit 1 Defueled Safety Analysis Report Site Plan (Operating Plant)

Figure 2-1 Amended: June 2008 TL:

C...

/

/

/

565.0' SAN ONOFRE NUCLEAR GENERATING STATION Unit 1 Defueled Safety Analysis Report Exclusion Area Boundary Figure 2-2 Amended: June 2008 TL:

IIT SAN ONOFRE NUCLEAR GENERATING STATION Unit 1 Defueled Safety Analysis Report Beach Passageway and Seawall Section Figure 2-3 Amended: June 2008 TL:

I, SAN ONOFRE NUCLEAR GENERATING STATION Unit 1 Defueled Safety Analysis Report Low Population Zone Figure 2-4 Amended: June 2008 TL:

San Onofre Unit 1 DSAR FACILITY DESCRIPTION 3.0 FACILITY DESCRIPTION 3.1 FACILITY DESCRIPTION 3.

1.1 INTRODUCTION

The SONGS 1 facility and planned Decommissioning activities are described in Sections 3.1 through 3.9. The Facility Description includes five sections dedicated to specific buildings and three sections for plant-wide topics: Electrical Systems, Monitoring and Communications, and Fire Protection.

Unit I is constantly changing during Decommissioning as the site is returned to conditions suitable for unrestricted use. The operating, radiological, and demolition status of the plant are carefully monitored and controlled by three SONGS organizations: the Operations, Health Physics and Decommissioning Divisions, respectively. Examples from the information systems maintained by these organizations are included in the DSAR. At any time, current plant information is available from the responsible organizations.

3.1.2 OPERATING STATUS The Operations Division is responsible for maintaining the operating configuration of Unit 1.

The active portions of the plant systems are defined by the Decommissioning P&IDs, which are distinguished from the original P&IDS by a "DE" suffix. The Decommissioning P&IDs are updated as required by the Plant Superintendent. Structures, systems and components that are Required to be Operational (RO) are identified on the Unit I Q-List (Dwg. M-37560).

3.1.3 RADIOLOGICAL STATUS The Health Physics (HP) Division monitors and controls the radiological status of Unit I areas and Decommissioning activities.

3.1.4 EQUIPMENT REMOVAL STATUS All systems, structures and components and their foundations have been removed or abandoned as described in sections 3.2 through 3.9. The remaining decommissioning activity is soil remediation, compaction and grading.

3.1.5 PLANT CONFIGURATION AT THE START OF DECOMMISSIONING The physical layout of Unit 1 that existed prior to any dismantlement is shown in the following general arrangement drawings:

Drawing Title 568700 General Arrangement - Plan of Elevation 35 ft - 6 in.

568701 General Arrangement - Plan of Elevation 14 ft - 0 in.

3-1 Amended: June 2008 TL:

San Onofre Unit 1 DSAR FACILITY DESCRIPTION 568702 General Arrangement Sections - Sheet 1.

568703 General Arrangement - Reactor Auxiliary Building and Intake Structure 568704 General Arrangement Sections - Sheet 2.

All of these historical drawings are provided for reference only.

3.1.6 QUALITY CLASSIFICATION OF STRUCTURES, SYSTEMS AND COMPONENTS 3.1.6.1 Quality Class Basis During reactor operation, quality classifications and Technical Specification requirements were based on protecting public health and safety primarily from anticipated operational occurrences and accidents affecting the reactor. The regulatory limits for radiological consequences were related to 10 CFR 100, and the structures, systems and components (SSC) required to ensure these limits are not exceeded were classified as Safety Related (SR). Other SSC were assigned lesser quality classifications depending on their relative importance to safety of the reactor.

These included Non Safety Related--Fire Protection (NSRFP), Non Safety Related--Anticipated Transients Without Scram (NSR-ATWS), and Non Safety Related (NSR).

Since operational occurrences were no longer possible after defueling, quality classifications were based on protecting public health and safety primarily from accidents affecting the spent fuel. The regulatory limits for radiological consequences are related to 10 CFR 20, and the SSC required to ensure these limits were not exceeded were designated as Required to be Operational (RO). Quality classifications for the RO structures, systems and components were assigned consistent with their relative importance to safety of the spent fuel. These include SR, NSRFP, and a new classification of Non Safety Related--Augmented Quality (NSRAQ). RO structures, systems and components are subject to Quality Assurance program requirements.

Accidents affecting the spent fuel are no longer possible with the fuel assemblies removed and transferred to the ISFSI. Quality classifications are now only required to be based on protecting public health and safety.

3.1.6.2 Required to be Operational SSC There are three quality classifications associated with the RO designation.

Safety Related (SR): Safety Related SSCs include components that prevent the consequences of postulated accidents that could cause.undue risk to the health and safety of the public. There are no Unit 1 facility components that are classified as SR.

Non Safety Related Fire Protection (NSRFP): Fire protection components which protect RO equipment are designated NSRFP and are covered by the QA program for Fire Protection. There are no Unit I facility components that are classified as NSRFP.

3-2 Amended: June 2008 TL:

San Onofre Unit I DSAR FACILITY DESCRIPTION Non Safety Related Augmented Quality (NSRAQ): RO items requiring augmented quality, are covered by the QA program. There are no Unit I facility components that are classified as NSRAQ.

3.1.6.3 Not Required to be Operational SSC Structures, systems, and components which are not important to protect the health and safety of the public are designated as Not Required to be Operational (NRO). NRO structures, systems and components are exempt from Quality Assurance program requirements. All NRO structures, systems and components have been assigned a quality classification of NSR 3.1.7 SEISMIC CLASSIFICATION OF SSC The seismic design of SONGS 1 was originally intended to ensure the most adverse conditions of stress and deflection resulting from the combined influence of normal and earthquake loads would not impair safe operation or orderly shutdown of the plant. The original seismic analysis and procedures are very conservative for the permanently defueled condition. The seismic classification system has not been changed for Decommissioning; the same categories are applied to the plant design:

Category A:

SSC that are important to the nuclear safety of the plant; Category B:

SSC that are important to the continuity of power generation or whose contained activity is such that release would not constitute a hazard; Category C:

All remaining SSC not required for safety and not directly associated with power generation.

In addition, a separate category includes those portions of SSC whose continued function is not required, but whose failure could reduce the fun'ctioning of any SSC important to safety to an unacceptable level and those portions of SSCs which form interfaces between Seismic Category A and Nonseismic Category A features. This category is in accordance with Regulatory Guide 1.29, Positions C.2 and C.3.

The Q-list retains the original seismic category designations which were applicable during power operation for historical interest to identify the construction design specifications for the structures.

3.1.8 QUALITY ASSURANCE CLASSIFICATION PROGRAM The requirements of the quality assurance program apply to the design, fabrication, construction, modification, testing, operation, and maintenance of structures, systems, and components (SSC) that prevent or mitigate the consequences of postulated accidents that could cause undue risk to the health and safety of the public as given in 10 CFR 50, Appendix B.

For Decommissioning the designations RO and NRO are used to determine Quality Assurance program applicability. SSC are classified using both the RO (or NRO) designations and the 3-3 Amended: June 2008 TL:

San Onofre Unit 1 DSAR FACILITY DESCRIPTION qualty class, as SR/RO, NSRFP/RO, NSRAQ/RO, or NSR/NRO. Normal plant quality assurance documentation is maintained for SSC designated as RO. For SSC designated as NRO, only the Q-List is maintained; other documentation does not require updating.

3.1.8.1 Q-List The Q-List defines the quality classifications of each SSC in Unit 1. The Q-List (SCE Document Number M-37560) is maintained as a controlled document under the SCE Quality Assurance Program.

3.1.8.2 Quality Groups Components containing water, steam, or radioactive material are assigned a quality group (A, B, C or D) in accordance with NRC Regulatory Guide 1.26, Rev. 2. These quality groups are part of a Quality Assurance program dedicated to assuring:

1) the integrity of the reactor coolant pressure boundary,
2) the capability to shut down the reactor and maintain it in a safe shutdown condition, or
3) the capability to prevent or mitigate the consequences of accidents which could cause undue risk to the health and safety of the public.

The current Q-list includes the R.G. 1.26 Quality Group classification for each component.

Since the first two objectives do not apply to a defueled plant, Quality Groups A and B are no longer relevant at SONGS 1 plant components but are used for the Spent Fuel Dry Cask Storage components. The quality groups are:

Quality Group A Group A quality standards are given in 10 CFR 50.55a and are applied to the design, fabrication, erection, and testing of reactor coolant pressure boundary components.

Quality Group B Group B quality standards are given in Regulatory Guide 1.26 and are applied to the water-and-steam-containing components identified in regulatory position C. I of Regulatory Guide 1.26.

Quality Group C Group C quality standards are given in Regulatory Guide 1.26 and are applied to the water-, steam-, and radioactive-waste-containing components identified in regulatory position C.2 of Regulatory Guide 1.26.

Quality Group D 3-4 Amended: June 2008 TL:

San Onofre Unit 1 DSAR FACILITY DESCRIPTION Group D quality standards are given in Regulatory Guide 1.26 and are applied to water-and steam-containing components not part of the reactor coolant pressure boundary nor included in Groups B and C but that are part of systems or portions of systems that contain or may contain radioactive material.

3.1.9 DESIGN CRITERIA FOR EVALUATIONS AND MODIFICATIONS OF EXISTING SSC SONGS 1 was designed and constructed before the General Design Criteria (GDC) current criteria were established for the analysis, design, and construction of nuclear power plants. The NRC's Systematic Evaluation Program (SEP) compared the existing configurations of the SONGS 1 structures, systems, and components with criteria that had evolved since the original design was developed.

3.1.9.1 Design Codes and Standards The original design codes and standards used to construct the operating plant are of historical interest and are presented in Reference 1. Limitations and exceptions to these codes and standards are identified in work package design criteria. Work performed on RO components is within the requirements of the Quality Assurance Program. Work that is not directly related to RO components, is performed in accordance with sound engineering practice and may use commercial standards and materials.

3.1.9.2 Electrical Engineering Design Criteria During Decommissioning, electrical work is generally performed under commercial grade standards.

3.1.9.3 Design Controls and Work Process The engineering design process and work activities at SONGS 1 are controlled under site-wide administrative controls. Design activities are planned, performed and documented in accordance with written procedures and instructions to assure control through all phases of design development, review and approval. Determination of 1 OCFR50 Appendix B requirements for design activities at SONGS 1 is based on the guidance of the TQAM and is implemented through controlled engineering procedures (SONGS ProceduresSection XXIV).

The requirements of 10CFR50.59 are implemented in accordance with the irecommendations and guidelines contained in NEI 96-07, Revision 1, Guidelines for 10 CFR 50.59 Implementation. A screening process is used to determine when a specific evaluation is required. Evaluations are preformed by personnel with pertinent technical expertise in the DSAR and Technical Specifications. The 50.59 process applied to SONGS 1 has been augmented to include a determination that proposed work is within the limits of 50.82(a)(6).

3.1.9.4 Deleted 3-5 Amended: June 2008 TL:

San Onofre Unit I DSAR FACILITY DESCRIPTION 3.1.10 REFERENCES

1. "San Onofre Generating Station Unit 1, Updated Final Safety Analysis Report," Docket 50-206 3-6 Amended: June 2008 TL:

San Onofre Unit 1 DSAR FACILITY DESCRIPTION 3.2 FUEL STORAGE FACILITY 3.

2.1 INTRODUCTION

The Fuel Storage Building was an independent and separate Seismic Category A structure which housed the spent fuel pool, an underwater cask transfer area, an underwater fuel transfer area, a cask decontamination area, a storage room, and an abandoned 480V switchgear room. The Fuel Storage Building was located southwest of the containment sphere.

3.2.2 FUEL STORAGE FACILITY STATUS Plant status is continually changing during Decommissioning. Current information on operating systems, radiological conditions, and demolition progress is maintained by the Operations, Health Physics, and Decommissioning Divisions, respectively. Refer to Section 3.1.2, 3.1.3, and 3.1.4.

All structures, systems and components associated with the Fuel Storage Facility have been removed or demolished. Spent fuel assemblies in the Unit 1 spent fuel pool, as well as Unit 1 spent fuel assemblies in the Unit 2 and Unit 3 spent fuel pools, were loaded into a specially designed cask and transferred to the Independent Spent Fuel Storage Installation (ISFSI).

Segmented GTCC waste from the reactor vessel internals was placed in GTCC waste container, and was similarly transferred to the ISFSI.

3.2.3 PLANNED DECOMMISSIONING ACTIVITIES The Fuel Storage Facility has been demolished. The remaining decommissioning activity is soil remediation, compaction and grading of the area.

3.2.4 DELETED 3.2.4.1 Deleted 3.2.5 DELETED 3.2.6 DELETED 3.2.6.1 Deleted 3.2.6.2 Deleted Table 3.2-1 Deleted Table 3.2-2 Deleted 3-7 Amended: June 2008 TL:

San Onofre Unit I DSAR FACILITY DESCRIPTION Table 3.2-3 Deleted 3.2.6.2.1.1 (Deleted) 3.2.6.2.1.2 (Deleted) 3.2.6.3 (Deleted) 3.2.6.3.1 (Deleted) 3.2.6.3.2 (Deleted) 3.2.6.4 (Deleted) 3.2.6.5 (Deleted) 3.2.6.5.1 (Deleted) 3.2.6.5.2 (Deleted) 3.2.6.5.3 (Deleted) 3.2.6.5.4 (Deleted)

Table 3.2-4 (Deleted)

Table 3.2-5 (Deleted) 3.

2.7 REFERENCES

1.

Deleted

2.

Deleted

3.

Deleted

4.

Deleted

5.

Deleted

6.

Deleted

7.

Deleted

8.

Deleted

9.

Deleted

10.

Deleted

11.

Deleted

12.

Deleted

13.

Deleted

14.

Deleted 3-8 Amended: June 2008 TL:

San Onofre Unit 1 DSAR FACILITY DESCRIPTION 3.3 SPHERE AND ENCLOSURE BUILDING 3.

3.1 INTRODUCTION

A spherical steel containment enclosed the reactor and its related equipment. The 140-foot diameter sphere was one-inch thick and extended 40 feet below grade. The sphere was continuously supported by a concrete cradle between the steel sheet and the undisturbed soil. A concrete foundation provided support and shielding for equipment inside the sphere. The concrete Sphere Enclosure Building surrounded the steel containment sphere. The building had three-foot thick cylindrical walls and a conical roof. It was designed to reduce the offsite dose during a design basis accident.

3.3.2 SPHERE AND ENCLOSURE BUILDING STATUS Plant status is continually changing during Decommissioning. Current information on operating systems, radiological conditions and demolition progress is maintained by the Operations, Health Physics and Decommissioning Divisions, respectively. Refer to being dismantled. Sections 3.1.2, 3.1.3 and 3.1.4.

All structures, systems and components internal to the Containment Sphere have been completely removed. The reactor vessel internal (RVI) components were cut up. Highly activated pieces that were greater than Class C (GTCC) were segmented, placed in a GTCC waste container and transferred to the Independent Spent Fuel storage installation (ISFSI). The remaining pieces were returned to the reactor vessel and stabilized by grouting. The reactor vessel has been packaged for shipment and is stored in the Unit I Industrial Area.

The Sphere Enclosure Building and its foundation have been completely demolished. The steel sphere has been removed. The lower portion of the concrete cradle foundation located below grade still remains. The bowl was filled with Elastozell and one foot of concrete up to elevation 8 1/2 feet.

3.3.3 PLANNED DECOMMISSIONING ACTIVITIES The Sphere and Enclosure Building has been demolished. The remaining decommissioning activity is soil remediation, compaction and grading of the area.

3.3.3.1 Deleted 3.3.3.2 Deleted 3.3.3.2.1 (Deleted) 3.3.3.2.2 (Deleted) 3.3.4 DESIGN EVALUATION 3.3.4.1 Deleted 3.3.4.2 Deleted 3.3.4.3 Deleted 3-9 Amended: June 2008 TL:

San Onofre Unit 1 DSAR FACILITY DESCRIPTION 3.3.4.4 Deleted 3.3.4.5 Deleted 3.3.5 BUILDING DESCRIPTIONS 3.3.5.1 Deleted 3.3.5.1.1 (Deleted) 3.3.5.1.2 (Deleted) 3.3.5.2 (Deleted) 3.3.6 DELETED 3.3.6.1 Deleted 3.3.6.2 Deleted 3.3.6.2.1 (Deleted) 3.3.6.2.2 (Deleted) 3.3.6.2.3 Deleted 3.3.6.3 (Deleted) 3.3.6.4 (Deleted) 3.3.6.4.1 (Deleted) 3.3.6.4.2 Deleted 3.3.6.5 Deleted 3.

3.7 REFERENCES

1. "Permanently Defueled Technical Specifications," Amendment No. 155 to License No.

DPR-13, Issued December 28, 1993

2. "Permanently Defueled Technical Specifications," Amendment No. 163 to License No.

DPR-I 3, Issued September 22, 2004 Table 3.3-1 Deleted 3-10 Amended: June 2008 TL:

San Onofre Unit 1 DSAR FACILITY DESCRIPTION 3.4 REACTOR AUXILIARY BUILDING 3.

4.1 INTRODUCTION

The Reactor Auxiliary Building contained the liquid and gaseous radwaste processing equipment and associated holdup tanks. A pipe tunnel connected the Reactor Auxiliary Building to the sphere piping penetration room (dog house). The Reactor Auxiliary building was a single story, partially embedded, reinforced concrete structure rising to about 6 feet above ground level. The northeast comer included a second story that was constructed of masonry walls, conventially reinforced concrete walls and slabs, and structural steel floor framing.

The overall dimensions of the Reactor Auxilisry Building was approximately 134 feet by 60 feet.

The northeast comer which comprised an additional story was approximately 32 feet by 41 feet.

The Reactor Auxiliary Building foundation was a reinforced mat, 2 feet 4 inches thick, 134 feet 4 inches long and 60 feet 2 inches wide, bearing directly on the San mateo formation. The lowest elevation of the basemat was at (-) 4 feet 4 inches.

The area surrounding the Reactor Auxiliary Building was known as the "backyard". The backyard area included equipment which supported the reactor primary systems. The area was paved and fenced forming the controlled boundary of the Radiological Control Area (RCA). The backyard provided access to the PASS lab, high rad storage vault, pipe tunnel, sphere penetration room, cryogenic building, ventilation building, and ion exchanger vault shield plugs.

3.4.2 REACTOR AUXILIARY BUILDING PLANT STATUS Plant status is continually changing during Decommissioning. Current information on operating systems, radiological conditions and demolition progress is maintained by the Operations, Health Physics, and Decommissioning Divisions, respectively. Refer to Sections 3.1.2, 3.1.3, and 3.1.4.

All structures, systems and components associated with the Reactor Auxiliary Building have been completely removed.

3.4.2.1 Deleted 3.4.2.2 Deleted 3.4.2.3 Deleted 3.4.2.4 Deleted 3.4.2.5 Deleted 3.4.2.6 Deleted 3.4.3 PLANNED DECOMMISSIONING ACTIVITIES The Reactor Auxiliary Building has been demolished. The remaining decommissioning activity is soil remediation, compaction and grading of the area.

3.4.4 DELETED 3-11 Amended: June 2008 TL:

San Onofre Unit 1 DSAR FACILITY DESCRIPTION 3.4.4.1 (Deleted) 3.4.4.2 (Deleted) 3.4.4.3 (Deleted) 3.4.4.4 (Deleted) 3.4.4.5 (Deleted) 3.4.4.6 (Deleted) 3.4.4.7 (Deleted) 3.4.5 (DELETED) 3.4.5.1 (Deleted) 3.4.5.2 (Deleted) 3.4.5.2.1 (Deleted) 3.4.5.2.2 (Deleted) 3.4.5.2.3 (Deleted) 3.4.5.2.4 (Deleted) 3.4.5.3 (Deleted) 3.4.6 DELETED 3.4.6.1 (Deleted) 3.4.6.2 (Deleted) 3.4.6.3 (Deleted) 3.4.6.4 (Deleted) 3.4.6.5 (Deleted) 3.4.6.6 (Deleted) 3.4.6.7 (Deleted) 3.4.6.8 (Deleted) 3.4.6.9 (Deleted) 3.4.6.10 (Deleted) 3.4.6.11 (Deleted) 3.4.6.12 (Deleted) 3.4.6.13 (Deleted) 3.4.6.14 (Deleted) 3.4.6.15 (Deleted) 3.4.6.16 (Deleted) 3.4.6.17 (Deleted) 3.4.6.18 (Deleted) 3.4.6.19 (Deleted) 3.4.7 DELETED 3.4.7.1 (Deleted) 3.4.7.2 (Deleted) 3.4.7.3 (Deleted) 3-12 Amended: June 2008 TL:

San Onofre Unit I DSAR FACILITY DESCRIPTION 3.5 INTAKE STRUCTURE 3.

5.1 INTRODUCTION

The Pacific Ocean provided cooling water for SONGS 1 cooling systems and dilution water for liquid releases. Water was drawn from an offshore intake structure which rests on a foundation located 33 feet beneath the ocean bottom and rises vertically to a point about 10 feet above the ocean floor. The inside horizontal dimensions of the offshore intake structure are 16 by 21 feet.

Two 12-foot inside diameter reinforced concrete pipes, extending about 3,200 feet and 2600 feet into the ocean, provided for the intake and discharge of seawater. These pipes are buried beneath the ocean bottom, with a minimum of 4 feet of sand cover over the top and 4 feet of rock cover surrounding the intake structure.

The intake pipe conveyed water to and from a concrete intake structure located on-shore. The intake structure was a as Seismic Category A buried reinforced concrete structure that housed:

(1) the components of the circulating water system, (2) the salt water cooling pumps which support the component cooling water system and, (3) the tsunami pit. The intake structure foundation was a reinforced concrete slab, 3 feet 4 inches thick, 136 feet 3-1/2 inches long with a varying width, bearing directly on the San mateo formation. The intake structure provided the structural transition from the pipes used to collect and discharge seawater for salt water cooling and to the ocean.

The intake tunnel consists of a 14-foot, 2-inch outside diameter intake pipe leading to a 12-foot-square box culvert to two pump chambers, with a maximum open cross section of 12 feet high by 23 feet wide. The pump well, where the salt water pumps are installed, had a 23-foot high peripheral retaining wall, and the pump chamber top slab formed the base of the pump well.

The discharge tunnel was 10 feet, 8 inches by 12 feet cross-section and it leads to the 14-foot, 2-inch diameter outfall tunnel.

The sea wall is a cantilevered sheetpile wall which runs along the western boundary of the site. It is protected with a 2-1/2 inch gunite coating which extends down to elevation 4 feet on the seaward face and down to 1 foot below finished grade on the landward face. The top and bottom elevations of the wall are 28.0 feet and (-) 8.0 feet respectively. The finished grade adjacent to the wall varies from elevation 14.5 feet to elevation 17.0 feet. The stone revetment on the seaward face extends from approximately elevation 5.0 feet to elevation 13.0 feet and is placed at an approximate 1.5:1 slope. The seawall is laterally supported by San Mateo sand.

The Domestic Water System consists of a header supplied with potable water which provides, drinking water and other domestic water system needs. To eliminate any potential for contaminating the domestic water system, backflow preventer are installed upstream of all use points.

3-13 Amended: June 2008 TL:

San Onofre Unit I DSAR FACILITY DESCRIPTION 3.5.2 INTAKE STRUCTURE Plant status is continually changing during Decommissioning. Current information on operating systems, radiological conditions and demolition progress is maintained by the Operations, Health Physics, and Decommissioning Divisions, respectively. Refer to Sections 3.1.2, 3.1.3, and 3.1.4.

All structures, systems and components associated with the Intake Structure including the Circulating Water System and Salt Water System have been removed from the site. The yard sump and overflow berm have been removed.

Except for the East wall of the intake structure circulation water pit, the entire structure was removed down to El 8 foot 6 inches. The East wall of the circulation water pit was removed down to grade which is approximately 13 foot 4 inches. The offshore circulating water conduits were sealed off in the Intake/Discharge Gate Structures by placing stop gates in the gate slots and slurry filling the structure up to 8 foot 6 inches. The remaining portions of the intake structure were filled up to El. 8 foot 6 inches with 70 pcf minimum Elastizell. The Turbine Plant Cooling Water line was breached between the Concrete Junction Box and Anchor Block 2 and the Discharge Structure Gate structure with slurry. The off-shore intake structure and tunnels were abandoned in place.

The seawall remains as the western security boundary of the site which is now the North Industrial Area but it has no other design function.

The Domestic Water System remains in service throughout the site, however, it no longer interfaces with any SSC associated with Unit 1.

3.5.3 PLANNED DECOMMISSIONING ACTIVITIES The Intake Structure and all associated equipment have been demolished or abandoned and decommissioning is complete.

3.5.4 DELETED 3.5.4.1 (Deleted) 3.5.4.2 (Deleted) 3.5.4.3 (Deleted) 3.5.4.4 (Deleted) 3.5.5 DELETED 3.5.5.1 (Deleted) 3.5.5.2 (Deleted) 3.5.6 DELETED 3.5.6.1 (Deleted) 3-14 Amended: June 2008 TL:

San Onofre Unit 1 DSAR FACILITY DESCRIPTION 3.5.6.2 (Deleted) 3.5.7 DELETED 3.5.7.1 (Deleted) 3.5.7.2 (Deleted) 3.

5.8 REFERENCES

1.

(Deleted)

2.

(Deleted)

3.

(Deleted)

4.

(Deleted) 3-15 Amended: June 2008 TL:

San Onofre Unit I DSAR FACILITY DESCRIPTION 3.6 TURBINE BUILDING 3.

6.1 INTRODUCTION

The Turbine Building consisted of four individual structural systems which surrounded the turbine pedestal. These four structural systems were the turbine building north and south extensions and east and west heater platforms. The Turbine Building area contained the main steam system, the turbine-generator unit, the electrical distribution system, compressed air system, and several other support systems related to power production.

The turbine building north extension was a one-story structural steel frame building with a mezzanine. It had approximate plan dimensions of 40 feet by 50 feet with an 8-1/2 inch thick prestressed concrete slab at elevation 42 feet, 0 inches, and a steel grating platform at elevation 30 feet, 0 inches. The west side of thie turbine building north extension was adjacent to the fuel storage building. Doors in the east wall of the fuel storage building provided personnel access to the spent fuel pool area from the turbine building north extension, elevation 42 feet, 0 inches.

Expansion joints were provided at the junctures between the turbine building north extension and other buildings, including the fuel storage building.

The turbine building foundation consisted of column spread and combined footings, bearing directly on the San Mateo formation. Footing width varies from 3 feet to 5 feet, while footing thickness varied from 2 feet, 6 inches, to 5 feet. Elevation of top of the footing varied from elevation 6 feet to elevation 17 feet, 7 inches.

3.6.2 TURBINE BUILDING STATUS Plant status is continually changing during Decommissioning. Current information on operating systems, radiological conditions and demolition progress is maintained by the Operations, Health Physics, and Decommissioning Divisions, respectively. Refer to Sections 3.1.2, 3.1.3, and 3.1.4.

The Turbine Pedestal Bottom mat, Anchor Blocks 1 and 2, intake culverts and discharge culverts have been abandoned. The anchor blocks, and the intake and discharge culverts have been filled with a 100 psi minimum slurry. The turbine pedestal foundation floor drains and the reheater pit sump and its drain line were filled with 100 psi slurry.

All other structures, systems and components associated with the Turbine Building have been removed from the site.

3.6.3 PLANNED DECOMMISSIONING ACTIVITIES The Turbine Building has been demolished. The remaining decommissioning activity is soil remediation, compaction and grading of the area.

3-16 Amended: June 2008 TL:

San Onofre Unit 1 DSAR FACILITY DESCRIPTION 3.6.4 DELETED 3.6.4.1 (Deleted)

Table 3.6-1 Deleted 3.6.4.2 (Deleted) 3.6.5 DELETED 3.6.5.1 (Deleted) 3.6.6 DELETED 3.6.6.1 (Deleted) 3.6.6.2 (Deleted) 3.6.6.3 (Deleted) 3.6.7 DELETED 3.6.7.1 (Deleted) 3.6.7.2 (Deleted) 3-17 Amended: June 2008 TL:

San Onofre Unit 1 DSAR FACILITY DESCRIPTION 3.7 ELECTRICAL SYSTEMS 3.

7.1 INTRODUCTION

The electric system that served SONGS 1 was electrically independent of SONGS 2 and 3.

Electrical isolation of most of the original electrical equipment was accomplished by Cold and Dark. Under cold and Dark, the station electrical system provided power to the facility from the SDG&E 12 kV system located at the Mesa. Substation "Gary" fed the North Construction load Center B34 and "Fran" fed Switchboard CD-5. Three motor control centers (CDI, CD2, CD3),

fed from CD-5 were installed by Cold and Dark. Two 120-208 VAC distribution panels CDI-DP1 and CD3-DP2 were powered from MCC-CD1 and MCC-CD3.

3.7.2 ELECTRICAL SYSTEM STATUS Plant status is continually changing during Decommissioning. Current information on operating systems, radiological conditions and demolition progress is maintained by the Operations, Health Physics, and Decommissioning Divisions, respectively. Refer to Sections 3.1.2, 3.1.3, and 3.1.4.

The electrical system that served SONGS I has been dismantled, demolished or abandoned. The SDG&E 12 kV system, 480V system, and the 120 VAC systems have all been removed.

A new electrical distribution system has been installed to support the North Industricl Area. The system consists of 480VAC load center 2/3B57 fed from SDG&E 12kV line "Gary" which provides electrical power for the North Security Processing Facility and North Industrial area yard Drain Sump Switchboard 2/3B58. A separate 480V substation is fed from SDG&E 12kV line"Fran". This s ubstation consists of Transformer X69A, Swithboard CD-5A, MCC-CD3A and 120-208VAC Distribution Panel CD3A-DP1. This substation supplies decommissioning loads and power to the Motor Operated gate MOG-1.

3.7.3 PLANNED DECOMMISSIONING ACTIVITIES There are no AC power systems remaining in service for SONGS 1. The AC power supply system installed and now serving the North Industrial Area does not interface with any SSC associated with Unit 1.

3.7.4 (DELETED) 3.7.4.1 (Deleted) 3.7.4.1.1 (Deleted) 3.7.4.1.2 (Deleted) 3.7.4.1.3 (Deleted) 3.7.4.2 (Deleted) 3-18 Amended: June 2008 TL:

San Onofre Unit 1 DSAR FACILITY DESCRIPTION 3.7.4.2.1 (Deleted) 3.7.4.2.2 (Deleted) 3.7.4.2.3 (Deleted) 3.7.4.2.4 (Deleted) 3.7.4.2.5 (Deleted) 3.7.4.3 (Deleted) 3.7.4.3.1 (Deleted) 3.7.4.3.2 (Deleted) 3-19 Amended: June 2008 TL:

San Onofre Unit I DSAR FACILITY DESCRIPTION 3.8 MONITORING AND COMMUNICATIONS 3.

8.1 INTRODUCTION

A new Control Room was located in the HP/Operations Building (A52). Plant conditions were monitored from the Control Room via a personal computer (PC). There were no control functions. Equipment was controlled locally by plant operators or, in a few cases, was automatically controlled.

3.8.2 MONITORING AND COMMUNICATIONS STATUS Plant status is continually changing during Decommissioning. Current information on operating systems, radiological conditions and demolition progress is maintained by the Operations, Health Physics, and Decommissioning Divisions, respectively. Refer to Sections 3.1.2, 3.1.3, and 3.1.4.

After all Unit 1 spent fuel was transferred to the ISFSI, the control room was no longer required.

The personal computer was moved to the Unit 2 Control Room for monitoring of the remaining operational systems. Equipment control responsibility was taken over by Unit 2/3 Operations.

3.8.3 PLANNED DECOMMISSIONING ACTIVITIES Decommissioning activities related to plant monitoring and communications have been completed.

3.8.4 DELETED 3.8.4.1 Deleted 3.8.5 DELETED 3.8.5.1 Deleted 3.8.5.1.1 (Deleted) 3.8.5.1.1.1 (Deleted) 3.8.5.1.1.2 (Deleted) 3.8.5.1.1.3 (Deleted) 3.8.5.1.1.4 (Deleted) 3.8.5.1.1.5 (Deleted) 3.8.5.1.2 (Deleted) 3.8.5.1.2.1 (Deleted) 3.8.5.1.2.2 (Deleted) 3.8.5.1.2.3 (Deleted) 3.8.5.2 Deleted Table 3.8-1 Deleted 3-20 Amended: June 2008 TL:

San Onofre Unit 1 DSAR FACILITY DESCRIPTION 3.9 FIRE PROTECTION 3.

9.1 INTRODUCTION

The fire protection program protected safety related equipment that was required to be operable.

The Unit 1 fire protection capability included permanent detection and suppression equipment, mobile fire apparatus and portable fire extinguishers. Additional fire protection features were in place to satisfy Nuclear Electric Insurance Limited (NEIL) Property and Loss prevention requirements and to provide defense-in-depth fire protection features for the surrounding structures. Administrative measures control the transient combustible materials and ignition sources.

3.9.2 FIRE PROTECTION STATUS Current information on operating systems and demolition progress is maintained by the Operations and Decommissioning Divisions, respectively. Refer to Sections 3.1.2 and 3.1.4.

All safety related equipment and buildings have been removed. Fire protection features were systematically abandoned and removed as fire hazards were eliminated and buildings were demolished. The fire protection system has been reduced to manual suppression capabilities throughout the Unit 1 Industrial Area.

Fire protection requirements are established by SO 123-FP-1, Fire Protection Program, which covers Units 1, 2 & 3. The reduced fire protection program requirements for the Unit 1 Industrial Area include control of combustibles, control of ignition sources, and manual suppression capabilities, including firewater supply and fire brigade staffing. The fire protection system includes sprinkler systems in occupied structures, fire extinguishers, hydrants and hose valves.

The water supply and pumping equipment are from Unit 2/3.

The fire protection system is further discussed in the Updated Fire Hazards Analysis (UFHA)

Section 6. The fire zones and fire protection features are shown on drawing 83321. This drawing is provided for reference only.

3.9.3 PLANNED DECOMMISSIONING ACTIVITIES The modification and/or removal of fire protection features will continue as conditions change during Decommissioning. Significant Decommissioning activities are reviewed by Fire Protection Engineering staff, who may require temporary or permanent fire protection features be established based on conditions at the time.

3.9.4 DELETED 3.9.4.1 Deleted 3.9.5 DELETED 3-21 Amended: June 2008 TL:

San Onofre Unit 1 DSAR FACILITY DESCRIPTION 3.9.6 DELETED 3.9.6.1 Deleted 3.9.6.2 Deleted 3.9.7 DELETED 3.9.7.1 (Deleted) 3.9.7.2 Deleted 3.9.7.3 Deleted 3.

9.8 REFERENCES

1. Deleted
2. Letter Huffman (NRC) to Ray (SCE), Subject, "San Onofre Nuclear Generating Station -

Unit 1-Issuance of Amendment Upon Transfer of All Spent Fuel Storage From The Spent Fuel Pool Into Dry Cast Storage (TAC No L52616)", dated September 22, 2004.

Amendment No. 163 to Facility Operating License No DPR-13 for SONGS Unit 1.

3-22 Amended: June 2008 TL:

SONGS Unit 1 DSAR Figure 3.1-1 (DELETED)

SONGS Unit 1 DSAR Figure 3.1-2 (DELETED)

Amended: June 2008 TL:

SONGS Unit 1 DSAR Figure 3.1-3 (DELETED)

Amended: June 2008 TL:.

SONGS Unit 1 DSAR Figure 3.1-4 (DELETED)

Amended: June 2008 TL:

SONGS Unit 1 DSAR Figure 3.1-5 (DELETED)

Amended: June 2008 TL:

SONGS Unit 1 DSAR Figure 3.1-6 (DELETED)

Amended: June 2008 TL:

SONGS Unit 1 DSAR Figure 3.2-1 (DELETED)

Amended: June 2008 TL:

SONGS Unit 1 DSAR Figure 3.2-2 (DELETED)

Amended: June 2008 TL:

SONGS Unit 1 DSAR Figure 3.2-3 (DELETED)

Amended: June 2008 TL:

SONGS Unit 1 DSAR Figure 3.2-4 (DELETED)

Amended: June 2008 TL:

SONGS Unit I DSAR Figure 3.2-5 (DELETED)

Amended: June 2008 TL:

SONGS Unit 1 DSAR Figure 3.2-6 (Deleted)

Amended: June 2008 TL:

SONGS Unit I DSAR Figure 3.2-7 (Deleted)

Amended: June 2008 TL:

SONGS Unit 1 DSAR Figure 3.2-8 (Deleted)

Amended: June 2008 TL:

SONGS Unit 1 DSAR Figure 3.2-9 (Deleted)

Amended: June 2008 TL:

SONGS Unit 1 DSAR Figure 3.2-10 (Deleted)

Amended: June 2008 TL:

SONGS Unit I DSAR Figure 3.2-11 (Deleted)

Amended: June 2008 TL:

SONGS Unit 1 DSAR Figure 3.2-12 (Deleted)

Amended: June 2008 TL:

SONGS Unit 1 DSAR Figure 3.2-13 (Deleted)

Amended: June 2008 TL:

SONGS Unit 1 DSAR Figure 3.2-14 (Deleted)

Amended: June 2008 TL:

SONGS Unit 1 DSAR Figure 3.2-15 (Deleted)

Amended: June 2008 TL:

SONGS Unit 1 DSAR Figure 3.2-16 (Deleted)

Amended: June 2008 TL:

SONGS Unit 1 DSAR Figure 3.2-17 (Deleted)

Amended: June 2008 TL:

SONGS Unit 1 DSAR Figure 3.2-18 (Deleted)

Amended: June 2008 TL:

SONGS Unit 1 DSAR Figure 3.2-19 (Deleted)

Amended: June 2008 TL:

SONGS Unit 1 DSAR Figure 3.2-20 (Deleted)

Amended: June 2008 TL:

SONGS Unit 1 DSAR Figure 3.3-1 (DELETED)

Amended: June 2008 TL:

SONGS Unit 1 DSAR Figure 3.3-2 (DELETED)

Amended: June 2008 TL:

SONGS Unit 1 DSAR Figure 3.3-3 (Deleted)

Amended: June 2008 TL:

SONGS Unit 1 DSAR Figure 3.3-4 (Deleted)

Amended: June 2008 TL:

SONGS Unit I DSAR Figure 3.6-1 (Deleted)

Amended: June 2008 TL:

Unit 1 Fire Area Boundaries and Fire Protection Features See UFHA Section 6 Amended: June 2008 TL:

San Onofre Unit 1 DSAR LICENSEE ORGANIZATION AND CONDUCT OF OPERATIONS 4.0 LICENSEE ORGANIZATION AND CONDUCT OF OPERATIONS 4.1 CORPORATE ORGANIZATION This section provides information relative to the corporate organization, its functions and responsibilities, and the qualification of personnel participating in the facility design, design review, design approval, testing, maintenance, operation, modification and decommissioning.

4.1.1 CORPORATE ORGANIZATION FUNCTIONS, RESPONSIBILITIES, AND AUTHORITIES The Southern California Edison Company (SCE) provides electric service to Southern California and operates San Onofre. The company has extensive experience in the design, construction, startup testing, operation, and staffing of modern generating facilities.

The corporate organization, which provides line responsibility for company operation, is shown in Figures 4-1 and 4-2. The ultimate responsibility for operating, maintaining, repairing, inspecting, testing, refueling, modifying, and decommissioning SONGS 1 rests with the Chief Executive Officer. He assigns responsibilities to various SCE organizations involved in Nuclear Generating Station Operations.

The Chief Nuclear Officer, who reports to the Chief Executive Officer, is responsible for the Site Manager, SONGS, the Nuclear Regulatory Affairs Division, the Nuclear Oversight and Assessment Division and the Nuclear Engineering & Technical Services Department.

4.1.2 CORPORATE MANAGEMENT AND TECHNICAL SUPPORT 4.1.2.1 Nuclear Engineering & Technical Services The Vice-President of Nuclear Engineering and Technical Services (E&TS) has responsibility for Nuclear Fuel Management, Design Engineering, Maintenance/Systems Engineering, Site Support Services, Strategic Issues Project, Projects, Engineering Standards and Excellence, Site Emergency Preparedness, Site Security, Business Planning and Financial Services, and Nuclear Business Administration as shown in Figure 4-3. Also, Nuclear Information Services is matrixed to this organization. These groups provide engineering change package preparation and engineering analysis. The engineering staff requests and coordinates support from other departments in the company, or from outside consultants and engineering firms, as needed. The Unit 1 Decommissioning Organization reports to the Manager of Projects, who in turn reports to the Vice-President of Nuclear E&TS.

4.1.2.2 Site Manager, SONGS The Site Manager, SONGS has ultimate responsibility for the safe operation of the three San Onofre Nuclear units. As shown in Figure 4-3, this individual is responsible for: Operations, Maintenance and Construction Services, Health Physics, Nuclear Training, Chemistry, and Work 4-1 Amended: June 2008 TL:

San Onofre Unit 1 DSAR LICENSEE ORGANIZATION AND CONDUCT OF OPERATIONS Control. Also, Nuclear Communications is matrixed to this organization. The operations organization provides support to SONGS 1.

4.1.2.3 Nuclear Oversight and Assessments, and Nuclear Regulatory Affairs These groups provide quality assurance and licensing services/submittals. All SONGS 1 licensing issues are addressed by the Director of Nuclear Regulatory Affairs.

The Nuclear Oversight and Assessment organization is responsible for the establishment and execution of the SCE Quality Assurance Program in compliance with I OCFR50, Appendix B, and other appropriate regulations and standards. The Director of Nuclear Oversight and Assessment is responsible for establishing quality assurance policies, goals, and objectives and ensuring that these policies are followed and that the goals and objectives are achieved. The quality assurance organization is described in the SCE QA Topical Report.

4.1.2.4 Qualification of E&TS Staff Members of the E&TS staff available for the technical support of SONGS have the education, experience, and skills, commensurate with their level of responsibility. The qualifications provide reasonable assurance that decisions and actions during the decommissioning of SONGS I will not constitute a hazard to the health and safety of the public.

The education and experience of the E&TS staff meet or exceed the requirements for technical support personnel as stated in ANSI N18.1-1971 and Regulatory Guide 1.8, Revision 1.

Definition of personnel performing technical support functions is provided in applicable station procedures.

4.1.2.5 Consultants, Contractors, and Suppliers Consultants and specialty contractors will be utilized as necessary. Consultant/contractor personnel will report to utility staff responsible for management and oversight of decommissioning activities.

Various other contractors, suppliers, and consultants are utilized as required to provide specialized support and services.

4.2 PLANT ORGANIZATION 4.2.1 SONGS I DECOMMISSIONING PROJECT The Manager, SONGS 1 Decommissioning reports to the Manager, Projects and is responsible for the decommissioning of SONGS 1. He is responsible for overall strategy and long-term business planning of decommissioning activities, establishing and ensuring achievement of objectives and initiatives associated with decommissioning activities of SONGS 1, and, safely and efficiently decommissioning SONGS I in accordance with applicable regulations and project cost and schedule. The Decommissioning Project organization plans, prepares, and performs the 4-2 Amended: June 2008 TL:

San Onofre Unit 1 DSAR LICENSEE ORGANIZATION AND CONDUCT OF OPERATIONS safe and prudent decommissioning of SONGS 1 in accordance with all requirements while not adversely affecting the operation of SONGS 2 and 3. The organization is shown on Figure 4-3.

The project is supported by other E&TS and SONGS organizations. A Decommissioning Executive Board consisting of management representatives from SCE and SDG&E oversees and monitors decommissioning efforts through periodic reviews of plans, schedules, and progress.

4.2.1.1 (Deleted) 4.2.1.2 Project Manager(s)

Project Manager(s), (reporting to the Manager, SONGS 1 Decommissioning) are responsible for decommissioning projects as assigned by the Decommissioning Manager. They are responsible for directing and overseeing staff in accomplishing the physical activities to prepare the plant for decommissioning, and in performing dismantlement, disassembly, removal, decontamination, and packaging of structures, systems and components that constitute decommissioning. They procure and manage contractors, provide field oversight, secure and coordinate Health Physics and Low Level Radwaste (LLRW) support.

4.2.1.3 Health Physics/Low Level Radwaste Supervisor The Health Physics/Low Level Radwaste Supervisor is matrixed from Health Physics and reports directly to the Manager, SONGS I Decommissioning. He is responsible for managing the radiological work planning and production based on the project schedule. He maintains a staff necessary for regulatory compliance, and the safe and cost effective collection, sorting, packaging, shipping and disposal of LLRW resulting from the decommissioning of SONGS I for the duration of the project.

4.2.1.4 Project Cost and Schedule Manager The Project Cost and Schedule Manager is matrixed from Business Planning and Financial Services and reports directly to the Manager, SONGS 1 Decommissioning. He is responsible for implementing and managing the budget, cost accounting, cost controls, planning, and scheduling activities for the SONGS I Decomissioning Project.

4.2.1.5 External Affairs Proiect Manager The External Affairs Project Manager is matrixed from Business Planning and Financial Services and reports directly to the Manager, SONGS 1 Decommissioning. He is responsible for:

ED Coordinating all regulatory proceedings required by the California Public Utilities Commission for the decommissioning project; 0 Ensuring the decommissioning project obtains and meets the conditions of all permits and/or easement lease contracts required by state regulatory agencies.

K.

4.2.1.6 Construction Supervisor 4-3 Amended: June 2008 TL:

San Onofre Unit 1 DSAR LICENSEE ORGANIZATION AND CONDUCT OF OPERATIONS The Construction Supervisor is matrixed from Maintenance and Construction Services (M&CS) and reports directly to the Manager, SONGS 1 Decommissioning. He is responsible for overall management oversight of SONGS 1 field activities performed by M&CS The Construction Supervisor is generally responsible for maintaining SONGS 1 housekeeping.

4.2.1.7 Supervisor, Unit I Decommissioning Engineering Support The Supervisor, Unit 1 Decommissioning Engineering Support is matrixed from Design Engineering in E&TS and reports directly to the Manager, SONGS 1 Decommissioning. He is responsible for coordinating all engineering work associated with SONGS 1..

4.2.2 (DELETED) 4.2.3 EQUIPMENT MAINTENANCE SUPERVISION The Manager, Maintenance and Construction Services, reports to the Site Manager, SONGS and is responsible for all mechanical, instrumentation and controls, and electrical maintenance.

The maintenance force consists of personnel experienced with mechanical, instrumentation and controls, and electrical maintenance of large steam electrical generating plants, nuclear and/or fossil. Major maintenance is handled by the station maintenance force, and various in-house and contract service organizations as circumstances dictate.

The Manager, Maintenance and Construction Services cooperates closely with the Manager, Operations, and other staff managers and supervisors in scheduling work.

4.2.4 HEALTH PHYSICS SUPERVISION The Manager, Health Physics, (HPM) reports to the Site Manager, SONGS and is responsible for the station radiatiOn protection program. He is responsible for providing station health physics support to operational, maintenance, and decommissioning activities. In addition, the HPM is responsible for the shipment and disposal of radioactive waste, personnel radiation monitoring measurements, a comprehensive respiratory protection program, a self-assessment and corrective action program, and an ALARA program. The HPM ensures that adequate protective clothing is available at all times. The HPM is responsible for properly maintaining all required radiation exposure records for station personnel and visitors. The HPM will distribute the function of the Health Physics Program among the Health Physics Management Team.

The HP Supervisor, Unit 1 Decommissioning, reports to the HPM and is responsible for providing radiological protection services to the Unit I Decommissioning project including operational health physics, personnel dosimetry, respiratory protection, instrumentation, technical/professional support, determining the feasibility of unrestricted release of structures and components, radwaste disposal, and environmental effluent controls.

The Supervisor, HP Operational Support reports to the HP Manager and is responsible for ensuring adequate health physics support is provided to operations and maintenance personnel 4-4 Amended: June 2008 TL:

San Onofre Unit 1 DSAR LICENSEE ORGANIZATION AND CONDUCT OF OPERATIONS during normal operations and emergency conditions, and for controlling access to Units 2 and 3 radiologically controlled areas. The HP Operational Support supervisor is also responsible for ensuring that all personnel radiation doses are properly measured, recorded in individual exposure histories, and that resultant records are properly maintained as required by regulation.

In addition, the supervisor is responsible for operation of a comprehensive respiratory protection program.

The Supervisor of Radioactive Materials Control (RMC) reports to the HPM, and is responsible for ensuring radioactive waste shipments meet all applicable transportation and packaging requirements. In addition, the Supervisor is responsible for ensuring waste is properly disposed by transferring the waste to authorized facilities. The Supervisor of RMC is also responsible for the receipt and storage of radioactive materials shipments.

The Health Physics Technical Support Supervisor reports to the HPM and is responsible for providing technical support for all aspects of the Health Physics program. The Supervisor/staff are responsible for interpreting and applying regulations across the HP program, for developing and controlling program procedures, and for coordinating software development and maintenance with the Information Systems organization.

The Supervisor, HP Instrumentation reports to the HP Manager and is responsible to provide, calibrate, and maintain all portable and fixed radiation instrumentation required by the HP program. The Supervisor is also responsible for the control, inventory and periodic leak testing of all radioactive sources used on site for the calibration of HP and plant equipment.

The Supervisor, Self-Assessment reports to the HP Manager and is responsible for the self-assessment program and for associated corrective actions.

The ALARA Supervisor reports to the HP Manager and is responsible for the site-wide ALARA program. The Supervisor assists in the development and tracking of exposure goals. The Supervisor performs regular reviews and provides regular status reports of project and personnel exposures. Some aspects of the ALARA program are delegated to an ALARA Engineer assigned to Unit 1.

4.2.5 QUALITY ASSURANCE AND QUALITY CONTROL SUPERVISION The Site Manager, SONGS has ultimate responsibility for the safe and reliable operation, maintenance, and testing of SONGS. He is responsible for the management of station activities in conformance with the Quality Assurance program.

Verification of station activities as being performed in conformance with the Quality Assurance program is accomplished by inspection, audit and surveillance by Nuclear Oversight and Assessment. Quality assurance and quality control personnel are located at the station and report to theDirector of Nuclear Oversight and Assessment.

The Director of Nuclear Oversight and Assessment reports to the Chief Nuclear Officer, and is responsible for the development, maintenance, and surveillance of the Quality Assurance 4-5 Amended: June 2008 TL:

San Onofre Unit 1 DSAR LICENSEE ORGANIZATION AND CONDUCT OF OPERATIONS Program. The Director of Nuclear Oversight and Assessment is responsible for surveillance of safety-related activities and has the authority to stop work.

The Project Oversight Manager is responsible for the quality assurance, quality control, and self assessment of the Decommissioning Project and Dry Fuel Storage.

4.3 QUALIFICATION OF NUCLEAR PLANT PERSONNEL The recommendations of ANSI N 18.1-1971, Standard for Selection and Training of Personnel for Nuclear Power Plants, for comparable positions, except for the manager, Health Physics, are currently used as the basis for establishing minimum qualifications for all management, supervisory, and professional-technical personnel in the plant organization.

The education, training, and experience requirements for operators, technicians, and repairmen meet the qualifications for these positions stated in ANSI N18.1-1971. Established company training and apprenticeship programs include documented academic and on-the-job training, as well as comprehensive qualification examinations. The length of these programs varies from a minimum of 24 months to a maximum of 48 months, with most requiring 30 months.

Technicians without prior experience receive academic training from the SCE training department for a period of about 2 years before being considered fully qualified for this position.

The key management supervisory and technical positions in the plant organizations are filled by persons who have been actively engaged in the nuclear power field.

4.4 TRAINING PROGRAM SCE maintains training programs during the decommissioning period that comply with the PDTS. The training programs, in concert with other managerial systems, ensure that qualified individuals are available to support decommissioning activities and protect the health and safety of plant personnel and the public.

SONGS 1 is maintained by a common SONGS 1, 2 and 3 work force, during the decommissioning period. The existing training programs will remain in effect and be utilized to the appropriate degree for personnel requiring access to or involved in maintaining SONGS 1.

The following are examples of existing training programs:

General Employee Training (GET)

Radiation Protection Training Chemistry Technician Training Operator Training Maintenance Training Emergency Plan Training Security Training Quality Assurance Training Dosimetry and ALARA Training Safety Training, 4-6 Amended: June 2008 TL:

San Onofre Unit 1 DSAR LICENSEE ORGANIZATION AND CONDUCT OF OPERATIONS 4.4.1 SCOPE OF TRAINING The training given to site personnel provides individuals with the necessary knowledge and skills to perform their job functions. SCE will continue to provide specialized training applicable to specific activities, tasks, and conditions, as needed.

4.4.1.1 General Employee Training SCE maintains the general employee training and access requirements for SONGS 1 employees and contractor/visitors. Access for radiation and non-radiation workers is controlled during the Decommissioning period. SONGS I has been separated from the Units 2/3 Protected Area and some of the physical security requirements have been relaxed.

4.4.1.2 Radiation Protection/Chemistry Technician Training The Health Physics and Chemistry training programs meet or exceed the existing requirements at SONGS 1 and are not affected by the shutdown of the unit.

4.4.1.3 Operator Training The current certification program for Unit 1 operators is conducted in accordance with the administrative controls established by the SONGS Nuclear Training Division (NTD). SCE is a member of the National Academy for Nuclear Training and is accredited by the Institute of Nuclear Power Operations (INPO). The program for Unit 1 is no longer conducted as an accredited program since there are no formal INPO program requirements for the defueled plant.

The SONGS 1 program is conducted under the administrative controls and procedures similar to those used for the accredited program at Unit 2 & 3. The accredited program was approved by the academy as indicated in references I and 2. SCE maintains accreditation by repeating the accreditation process every 4 years.

4.4.1.4 (Deleted) 4.4.1.5 (Deleted) 4.4.1.6 Maintenance Training SCE uses a Maintenance work force that is common to all three units. Maintenance training programs have not been changed or affected by the Decommissioning of SONGS 1. Specific training for SONGS 1 is developed and programmatically implemented as new tasks are identified.

4.4.1.7 Trainer Qualifications SONGS procedures establish managerial controls to ensure training activities comply with the requirements of the SONGS 1 Operating (Possession Only) License, PDTS and applicable 4-7 Amended: June 2008 TL:

San Onofre Unit I DSAR LICENSEE ORGANIZATION AND CONDUCT OF OPERATIONS regulations. SCE reviews instructor qualifications to ensure trainers possess the knowledge, experience, and abilities to provide the required training.

4.4.1.8 Training Records SCE documents and maintains records of required training in accordance with appropriate procedures.

4.5 REVIEW AND AUDIT Operations affecting nuclear safety are independently reviewed and audited by company organizations other than those directly responsible for the activity. The review and audit program ensures that proper review and evaluation is conducted for proposed facility and procedure changes, tests, experiments, and unplanned events. This program complies with the associated requirements in 10CFR50 paragraph 50.59 and is conducted in accordance with the recommendations of Regulatory Guide 1.33, Quality Assurance Program Requirements (Operation), and ANSI Standard N18.7-1976, Administrative Controls and Quality Assurance for the Operational Phase of Nuclear Power Plants.

The Site Manager, SONGS has ultimate onsite responsibility for the safety of SONGS 1 and is kept abreast of plant operating conditions by onsite managers and supervisors who are knowledgeable and experienced in their areas ofjob responsibility. Figure 4-4 illustrates the relationship between SCE's independent review organizations.

4.5.1 ONSITE REVIEW The Onsite Review Committee has overall responsibility for the review of nuclear safety aspects of station administration, maintenance, and operational-activities. The methods used to exercise this responsibility will ensure that before they are approved, items of this nature are reviewed for adequacy by qualified personnel at the appropriate technical and managerial level(s). Control over proper implementation will be maintained under the authority of the committee in a manner consistent with SCE corporate policy, approved procedures, and regulatory and licensing requirements. A detailed description of the Onsite Review Committee and its responsibilities and authority is provided in QA Topical Report Section 17.2.20.2, "Onsite Review Committee (OSRC)."

4.5.2 NUCLEAR SAFETY GROUP The Nuclear Safety Group provides onsite independent review of operating activities and is described in detail in QA Topical Report Section 17.2.20.4, "Nuclear Safety Group (NSG)." The Nuclear Safety Group is a staff organization composed of a supervisor and at least three independent review specialists who collectively have the experience and competence required to perform technical review. For those matters where additional expertise is necessary or desirable, consultants are used from within and outside SCE. The Nuclear Safety Group can request the 4-8 Amended: June 2008 TL:

San Onofre Unit 1 DSAR LICENSEE ORGANIZATION AND CONDUCT OF OPERATIONS performance of special reviews, investigations or analyses by the onsite review committee. The Nuclear Safety Group maintains written records of its reviews and recommendations.

4.5.3 AUDIT PROGRAM A comprehensive system of planned and documented audits is carried out to verify compliance with all aspects of administrative controls and the quality assurance program.

The quality assurance organization performs audits as outlined in QA Topical Report Section 17.2.18, "Audits," under the cognizance of the Director of Nuclear Oversight and Assessment.

These audits are performed with a frequency commensurate with their safety significance and encompass:

(1)

Conformance of facility operation to applicable license conditions and technical specifications, (2)

Training and qualifications of the operating staff, (3)

Corrective actions at 6-month intervals to correct deficient items affecting nuclear

safety, (4)

Quality assurance program, (5)

Facility emergency plan, (6)

Facility security plan, (7)

Facility fire protection plan, and (8)

Any area considered appropriate by the nuclear safety group or the nuclear control board.

The Nuclear Oversight and Assessment Division is responsible for auditing any activity or documentation affecting the quality of a safety-related item. Audits are performed by quality assurance engineers or other qualified persons designated by the Director of Nuclear Oversight and Assessment. These audits are performed at the general office, the station, Westminster, or the contractor's, vendor's, or consultant's source locations as required. The quality assurance audit program for operations is described in the SCE topical report SCE-1-A.

4.6 PLANT PROCEDURES This section describes administrative and operating procedures used by the operating organization to ensure that routine operating, off-normal, and emergency activities are conducted in a safe manner. All safety-related operations are conducted in accordance with detailed written and approved procedures as described in PDTS 6.8.

4-9 Amended: June 2008 TL:

San Onofre Unit 1 DSAR LICENSEE ORGANIZATION AND CONDUCT OF OPERATIONS 4.6.1 ADMINISTRATIVE PROCEDURES 4.6.1.1 Conformance with Regulatory Guide 1.33 The administrative procedures for SONGS 1 are consistent with the recommendations of Regulatory Guide 1.33, Revision 2.

4.6.1.2 Preparation of Procedures Cognizant station managers are responsible for initiating, preparing, and controlling plant procedures consistent with their responsibilities and ensuring that work is performed in accordance with the latest applicable documents.

Administrative procedures governing the conduct of operations are written to be applicable to SONGS 1 as well as SONGS 2 and 3, to the maximum extent possible.

4.6.1.3 Procedures Administrative procedures prepared for SONGS I include special procedures, equipment control procedures, and procedures for equipment maintenance and modification.

4.6.1.3.1 (Deleted) 4.6.1.3.2 Special Procedures Special procedures are prepared to control processes performed only once or for a short period of time. They expire 12 months after they are approved.

4.6.1.3.3 Equipment Control Procedures All remaining Unit I in-service equipment is administratively controlled from Units 2/3 using the Units 2/3 processes and procedures.

4.6.1.3.4 Control of Maintenance and Modifications Maintenance of equipment important to safety is accomplished in accordance with written procedures. Safety-related/RO equipment is modified in accordance with written procedures.

4.6.1.3.5 Master Surveillance Testing Schedule Surveillance testing procedures maintained under Decommissioning are in accordance with commitments contained in the Administrative Controls Document. These include:

Radiological surveys, Calibration and control of measuring and test instrumentation.

4-10 Amended: June 2008 TL:

San Onofre Unit 1 DSAR LICENSEE ORGANIZATION AND CONDUCT OF OPERATIONS 4.6.1.3.6 Log Book Usage and Control All Unit 1 Operations logs are maintained and controlled at Units 2/3 using the Units 2/3 processes and procedures.

4.6.2 OPERATING AND MAINTENANCE PROCEDURES 4.6.2.1 Operating Procedures All remaining Unit I equipment and processes requiring operating procedures have been incorporated into Units 2/3 procedures and programs.

4.6.2.2 Other Procedures Other procedures are provided for health physics, emergency, instrument calibration and test, chemical and radiochemical control, radioactive waste management, maintenance, material control, plant security, and fire protection.

4.6.2.2.1 Health Physics Health physics procedures are designed to limit and control radiation exposures and the spread of contamination as well as to meet the requirements of 1 OCFR20 and ALARA philosophy.

Procedures in this area include:

Control and use of radioactive material, Respiratory protection,

ALARA, Personnel monitoring, Internal dosimetry and bioassay, Instrument calibration and control, Radiation, contamination, and airborne surveys, and Solid radwaste.

4.6.2.2.2 Emergency Preparedness Emergency preparedness procedures are provided to implement the provisions of the emergency plan. They provide for the assignment of responsibilities, instructions to employees, procedures for coping with emergency, and mobilization of offsite assistance where necessary.

4.6.2.2.3 Instrument Calibration and Test Instrument calibration and test procedures provide detailed step-by-step methods for calibration and test, acceptance criteria, and testing intervals performed by instrument technicians.

Procedures in this area include:

4-11 Amended: June 2008 TL:

San Onofre Unit 1 DSAR LICENSEE ORGANIZATION AND CONDUCT OF OPERATIONS Area radiation monitoring system calibration, Nuclear instrumentation system test and calibration, Process radiation monitoring system calibration, and Calibration of test instrumentation and devices.

4.6.2.2.4 Chemical-Radiochemical Control Chemical-radiochemical control procedures provide the instructions to accomplish various chemical and radiochemical analyses and counting techniques. These procedures apply to work performed by nuclear chemistry technicians. Procedures in this area include:

Boron analysis, Cesium analysis, Radioactive sample system operation, Chloride analysis, Fluoride analysis, and pH measurement.

4.6.2.2.5 Radioactive Waste Management Radioactive waste management procedures are included in plant health physics procedures.

4.6.2.2.6 Maintenance Maintenance procedures provide detailed instructions for important maintenance functions performed by maintenance and technical personnel. Procedures in this area include:

(1)

Maintenance station orders which present policies and responsibilities for maintenance programs, (2)

Maintenance administrative procedures which describe implementing details for maintenance program policies, (3)

Maintenance surveillance procedures which present performance details for inspections and tests assigned to the maintenance department, (4)

(Deleted)

(5)

Preventive maintenance procedures which present performance details for routine electrical and mechanical scheduled activities required to maintain safety-related and certain nonsafety-related equipment, components, and structures operable at the quality level necessary for them to perform their intended functions, and (6)

Corrective maintenance procedures which describe performance details for nonroutine electrical and mechanical equipment overhauls with replacements of life-limiting wear items. These may be scheduled based upon historical data, 4-12 Amended: June 2008 TL:

San Onofre Unit 1 DSAR LICENSEE ORGANIZATION AND CONDUCT OF OPERATIONS calendar time, operating hours, etc., or nonscheduled based upon failure or predicted failure.

4.6.2.2.7 Material Control Material control procedures describe the methods used to control the status of purchased material and nonconforming material. These procedures include:

Control of purchased material, equipment, and services, Handling, storage, and shipment of materials, and Nonconforming materials, parts, components, and operations.

4.6.2.2.8 Plant Security Plant security procedures provide instructions for implementing the security plan.

4.6.2.2.9 Fire Protection Fire protection procedures provide instructions for implementing the fire protection plan (see Fire Protection Section).

Provisions for human verification of operating and maintenance activities are addressed within station procedures. The extent of human verification depends upon the amount of automatic system status monitoring equipment installed.

4.7 REFERENCES

1. (Deleted)
2. "Permanently Defueled Technical Specifications," Amendment No. 155 to License No.

DPR-13, Issued December 28, 1993

3. "San Onofre Generating Station Unit 1, Updated Final Safety and Analysis Report," Docket 50-206
4. "Post Shutdown Decommissioning Activities Report (PSDAR)," dated December 15, 1998 4-13 Amended: June 2008 TL:

EDISON INTERNATIONAL EDISON INTERNATIONAL

.Chairman Chief Executive Officer President (positions may be held by individuals or-concurrently by one or two persons)

EDISON MISSION GROUP, INC.

Chairman Chief Executive Officer.

President (positions may be held by; individuals or concurrently by one or two persons)

I SOUTHERN CALIFORNIA EDISON COMPANY Chairman Chief Executive Officer President (positions may be held by individuals or concurrently by one or two persons)

EEDISON INTERNATIONAL" SAN ONOFRE NUCLEAR GENERATING STATION Unit 1 Defueled Safety Analysis Report Edison International Companies Figure 4-1 Amended: June 2008 TL:

SOUTHERN CALIFORNIA EDISON COMPANY SOUTHERN CALIFORNIA Chairman and Chief EDISON~

Executive Officer (may be held by one individual or An EDISON INTERNATIONALO Company by two individuals)

President Generationfn Chief Nuclear Officer CC eguatRegulatory PONiuryR

& Affairs, Affa Revenue & s--pportunit Nuclear Engineering Tarif,. Af.,,,atoe

  • °°'

Site Manager, SONGS and Officer

.l Technical Services Business Customer Integration Service CPUC Regulatory t**

Nuclear Regulatory Washington D. C.,

Operations Generation Planning Nuclear Oversight

Safety, and Strategy and Assessment Operations oOPwearduto CL CD C-00

-4 NOFRE NUCLEAR GENERATING STATION Unit 1 Defueled Safety Analysis Report outhern California Edison Business Units Figure 4-2

NUCLEAR ORGANIZATION Work Control Operations Maintenance and Construction Services Site Support Services Engineering Standards and Excellence Strategic Issues Project Nuclear Training Projects Nuclear Communications SAN ONOFRE NUCLEAR GENERATING STATION Unit 1 Defuefed Safety Analysis Report NUCLEAR ORGANIZATION (Sheet 1 of 2)

Figure 4-3 Amended: June 2008 TL:

UNIT 1 DECOMMISSIONING Nuclear Engineering

& Technical Services Manager, SONGS 1 Decommissioning Engineering Support Health Physics/

Low Level Rad. Waste P

Project Managers External Affairs Construction Project Cost and Schedule SAN ONOFRE NUCLEAR GENERATING STATION Unit 1 Defueled Safety Analysis Report NUCLEAR ORGANIZATION (Sheet 2 of 2)

Figure 4-3 Amended: June 2008 TL:

INDEPENDENT REVIEW ORGANIZATION Nuclear Safety Group Audit..

Nuclear Oversight

~Audit Results Onsite Review Committee Coordination Functional Direction SAN ONOFRE NUCLEAR GENERATING STATION Unit 1 Defueled Safety Analysis Report Independent Review Organization Figure 4-4 Amended: June 2008 TL:

San Onofre Unit I DSAR RADIOACTIVE WASTE MANAGEMENT 5.0 RADIOACTIVE WASTE MANAGEMENT The radioactive waste management and disposal systems at SONGS 1 were designed to provide controlled handling and release or disposal of liquid, gaseous, and solid wastes generated. Plant personnel and the general public are protected from significant exposure to radiation from wastes. Releases of radioactive nuclides in either liquid or gaseous wastes discharged from the plant during Decommissioning are a small fraction of the quantity permitted under 10 CFR 20.

Additionally, the objective is to meet the numerical guidelines outlined in 10 CFR50, Appendix I, regarding "as low as is reasonably achievable."

Liquids are collected and processed by filtration prior to discharge to the ocean. The gas treatment systems are no longer required. There is no generation of fission product gases. The radiation monitoring system for airborne discharges has been demolished. Solid wastes are stored, packaged and shipped offsite for either (1) direct disposal at licensed burial facilities or (2) volume reduction licensed waste processor(s).

5.1 RADIOLOGICAL HISTORY Fuel cladding leakage occurred during several fuel cycles at SONGS 1. Monitoring programs such as primary chemistry, effluent chemistry and health physics detected fission product contamination and characterized the typical constituents of fission products and corrosion products. Activity of these isotopes could be found throughout systems that handled liquids and gases during normal operation.

The unit had a history of steam generator tube leakage. For this reason, secondary systems were considered suspect and were treated as such under the administrative programs. Similarly, liquid systems interfacing with known contaminated systems through heat exchangers were also considered suspect due to the possibility of tube leakage during operation. All plant sumps and drains were considered suspect, or were known to be contaminated and were also regarded as potentially contaminated.

5.2 CURRENT RADIOLOGICAL STATUS The Health Physics (HP) Division monitors and controls the radiological status of all Unit I areas and Decommissioning activities. At any time, current information on radiation and contamination levels is available from HP. The survey sheet presented in Figure 3.1-1 is an example of the radiological information that is maintained and utilized by HP in controlling work and protecting personnel.

The quantities of radioactive nuclides discharged from the SONGS 1 facility are presented in the Annual Radioactive Effluent Release Reports.0l)

With the cessation of operation in 1992, and the ensuing period of inactivity, the current inventories and normal releases of radioactivity at SONGS 1 have been greatly reduced from those which existed shortly after plant shutdown. The potential consequences of an accident or uncontrolled release are also much lower. Current conditions are very conservatively bounded by those that existed shortly after plant shutdown. These bounding values for activities, inventories 5-1 Amended: June 2008 TL:

San Onofre Unit 1 DSAR RADIOACTIVE WASTE MANAGEMENT and releases of radioactive products are included in Section 5.1 of Appendix A, Historical Information, as a point of reference.

5.2.1 SPENT FUEL POOL All spent fuel assemblies and hardware have been transferred to the Independent Spent Fuel Storage Facility (ISFSI).

An activation analysis of the reactor vessel and its internals wa's performed to generate radioactivity levels in these components (Reference 2). The results expressed in units of curies were used to segment the waste into low level radioactive waste shipments for near surface disposal and greater than Class C (GTCC) waste to be stored in the ISFSI. The total activity calculated for the vessel and non-GTCC internals as of 04/01/2002 was less than 5.0E+04 Curies. The total GTCC activity level calculated was less than 3.5 E+05 as of 04/01/2002.

GTCC waste has been' transferred to the ISFSI. The Reactor Vessel remains stored on site.

5.2.2 DELETED 5.2.3 AIRBORNE RELEASES Current airborne releases are well below the requirements of 10 CFR 20.106(b); 10 CFR 20 Appendix B Table II; and 10 CFR 50 Appendix I.

All building structures that previously contained, handled and or processed radioactive liquids and gases have been demolished. There are no more sources of noble gases or iodine. Local engineering controls are implemented to control the production of particulate airborne material and are assessed by Health Physics local air sampling.

5.2.4 ESTIMATED DOSES FOR AIRBORNE RELEASES Experience since plant shutdown has indicated that airborne radioactive releases are only a very small fraction of the allowable limits given in 10 CFR 20 Appendix B Table II.

5.2.5 LIQUID RELEASES All no plant liquid discharge systems have been demolished. Any liquid radwaste that is created is dispositioned per the site procedure SO 123-XV-29.

5.2.6 ESTIMATED DOSES FOR LIQUID RELEASES The calculated dose or dose commitment to a member of the public from radioactive materials in liquid effluents released to unrestricted areas is limited during any calendar quarter to <1.5 mrem to the total body and to <5 mrem to any organ and during any calendar year to <3 mrem to the total body and to <10 mrem to any organ. These dose allowances are in compliance with 10 CFR 50 Appendix I and 10 CFR 20.

5-2 Amended: June 2008 TL:

San Onofre Unit 1 DSAR RADIOACTIVE WASTE MANAGEMENT 5.2.7 DELETED 5.

2.8 REFERENCES

1.

San Onofre Nuclear Generating Station Radioactive Annual Effluent Release Report, June 1996.

2.

SO1-207-1-M106, San Onofre Nuclear Generating Station Unit 1 Reactor Vessel and Internals Characterization, Report WMG-20004-9088.

5.3 DELETED 5.3.1 (DELETED) 5.3.2 (DELETED) 5.3.3 (DELETED) 5.3.4 DELETED 5.4 DELETED 5.5 SOLID WASTE The handling of solid radwaste generated during all phases of Decommissioning is described in the following subsections.

The major sources of dry active waste are debris generated by building demolition and material removed from the plant as a part of Decommissioning. Controlled dismantlement methods are used to minimize the radioactive waste volume produced and to prevent the spread of contamination.

5.5.1 DESIGN OBJECTIVES The solid radwaste is packaged and stored until it is shipped offsite for permanent disposal at a licensed burial facility. The solid wastes are generated by dismantling and demolition activities.

The design objectives may be stated as follows:

(1)

To provide a means for collecting and processing the plant's radioactive waste streams in accordance with both regulatory and burial site criteria; (2)

To maintain any potential radiation exposure to plant personnel and the environment, as a result of the packaging, within the dose limits of I 0CFHII and 10CFR50; and 5-3 Amended: June 2008 TL:

San Onofre Unit 1 DSAR RADIOACTIVE WASTE MANAGEMENT (3)

To package the plant's solid radioactive wastes in conformance with the requirements of I OCFR61 and 10CFR71.

5.5.2 DELETED 5.5.3 SOLID RADWASTE EQUIPMENT AND PROCESSES 5.5.3.1 (DELETED) 5.5.3.2 Deleted 5.5.3.3 Dry Active Waste Collection and Processing The radioactive trash collected from the plant radioactive work areas may contain compactible dry active waste, noncompactible dry active waste, wet waste, and protective clothing. These items are segregated and collected in their respective receptacles at the exit point of the-contaminated work area. The trash is collected from these receptacles and is packaged according to its classification.

The collection containers (plastic bags) of dry active waste are inspected for other classes of waste such as noncompactible waste or "wet trash" before the dry active waste is loaded into a container. Compactible dry active waste is generally packaged and shipped offsite to a vendor who performs volume reduction.

The noncompactible waste is packaged in strong tight containers. After placing the maximum capacity of metallic objects in each box, the voids may be further filled by sifting sand/dirt or rubble into the box. The box is sealed and staged for shipment.

The wet trash is segregated and packaged into appropriate containers using appropriate operating procedures and controls to keep exposure ALARA.

The protective clothing collected from receptacles is packaged and transported offsite to a licensed facility for cleaning. If the protective clothing is determined to be not reusable, it is packaged according to directions for the disposition and burial offsite of compactible dry active waste or wet waste.

5.5.3.4 (DELETED) 5.5.3.5 Solidification Program for Wet Wastes At present, the solidification of SONGS solid radwaste is not accomplished at the site. However, packaging waste by solidification is feasible at SONGS 1. To ensure that the packaged waste would meet the burial site and regulatory requirements for packaging and shipping, the qualified service contractors must supply detailed information to SCE about the solidification process, the sampling program, verification for free standing water, and exothermic process considerations.

The information is evaluated before the service contract is awarded. After the award of contract, 5-4 Amended: June 2008 TL:

San Onofre Unit I DSAR RADIOACTIVE WASTE MANAGEMENT any special procedures required for this operation, such as sampling to ensure solidification and verification of the free standing water, are reviewed and may be accepted or rejected.

5.5.3.5.1 Deleted 5.5.3.6 Deleted 5.5.4 PACKAGING Before packaging, the solid radioactive waste is evaluated and classified in accordance with the requirements of 10 CFR 61. This classification determines the manner in which the solid radioactive waste is handled, packaged, labeled, and prepared for shipment in order to comply with all applicable regulations.

Several sizes of containers are used for packaging the radioactive solid waste. The dry active waste may be compressed into 55-gallon drums or, when noncompactible, packaged in strong tight containers of different dimensions. The wet solid waste materials are rendered dry prior to packaging and/or disposal.

The packaging containers conform to the applicable regulatory requirements of 10 CFR and 49 CFR and the criteria specified in the burial site licenses for receiving and burying solid radioactive waste.

5.5.5 DISMANTLEMENT, DECONTAMINATION, AND DISPOSAL During Decommissioning SCE may decontaminate and dismantle the contaminated structures, systems and components (SSC) by decontamination in place, dismantlement and decontamination, dismantlement and disposal, or a combination of these methods. Buildings will be dismantled and prepared for disposal. Appropriate methods will be selected for particular situations with the objectives of safely and efficiently removing the SSC while reducing contamination levels and worker exposure.

5.5.5.1 Decontamination Methods Contaminated systems and components are removed and sent to a processing facility or to a LLRW disposal facility. Onsite decontamination is generally limited to activities needed to maintain personnel exposure as low as reasonably achievable (ALARA), to expedite equipment removal, and to minimize the spread of contamination. Decontamination may also be conducted as part of volume reduction or as a step in the process to free release an item.

Fixation or removal of loose surface contamination is accomplished primarily by application of coatings and wiping. Airborne contamination control and waste processing systems are used, as necessary, to control and monitor such contamination if other methods are used, e.g., grit blasting or high pressure water. Openings in components are covered and sealed to minimize the spread of contamination as components are moved to packaging areas.

5-5 Amended: June 2008 TL:

San Onofre Unit 1 DSAR RADIOACTIVE WASTE MANAGEMENT 5.5.5.2 Dismantlement Controlled dismantlement methods will be used to remove SSC. Two basic types of dismantlement are mechanical and thermal.

Mechanical methods, those which machine the surfaces of the material being cut, typically do not generate significant amounts of contamination. This attribute makes these methods attractive for cutting contaminated piping and components. The outside diameter machining method is best suited for large bore piping. Smaller bore piping and supports can be cut using any of the mechanical methods, e.g., saws, reciprocating saws and hydraulic shears.

Thermal methods melt or vaporize the surfaces of the material being cut. The cutting debris is transported from the cut region with a gas jet or water spray. Although thermal methods are significantly quicker than mechanical methods, they generate airborne contamination.

Contamination control and effluent control measures are implemented, as appropriate, to minimize worker exposure and the potential for an unmonitored effluent release. HP&E Position Paper "Airborne Effluent Controls During Decommissioning," dated September 27, 2000, provided additional guidance on effluent control measures to minimize airborne effluents.

5.5.5.3 Processing Building Debris and Dismantled Equipment LLRW will be processed in accordance with plant procedures and shipped to an offsite processing facility or LLRW disposal facility. No incineration will occur onsite.

Concrete which cannot be decontaminated will be packaged and shipped to a LLRW disposal facility. Contaminated structural steel components may be removed to an onsite processing area for decontamination, volume reduction, and packaging for shipment to an appropriate facility.

5.5.5.4 Soil Remediation Soils and asphalt pavement will be surveyed and characterized in accordance with the Site characterization program. As necessary, soil and pavement will be removed, processed, and disposed of at a licensed LLRW processing or disposal facility if determined to contain contamination levels above those required for compliance with I 0CFR20, Subpart E.

5.5.6 STAGING, PROCESSING AND STORAGE FACILITIES Several areas may be used for the processes of decontamination, segregation, storage and packaging radioactive waste. Section 6.1 describes the South Yard Facility (SYF), and the Units 2&3 Truck Bay. The Multipurpose Handling Facility (MPHF), is described in this section.

The MPHF is an in-process staging area for the accumulation of solid radwaste until it is released for shipment. The MPHF consists of an office building, a staging building, and an equipment pad. The facility is surrounded by a gated chain link fence. The MPHF is located at the southern edge of the SONGS owner-controlled area. The location of the facility with respect to SONGS 1 is presented in Figure 2.1.

5-6 Amended: June 2008 TL:

San Onofre Unit 1 DSAR RADIOACTIVE WASTE MANAGEMENT The following subsections present a general overview of each area.

5.5.6.1 Office Building and Equipment Pad The office building houses, the office, control room, equipment room, and locker rooms, and also serves as the main personnel access to the MPHF. The equipment pad is on the east side and adjacent to the office building. Located on the equipment pad are the air handling units ductwork and effluent monitoring equipment for the staging building.

5.5.6.2 Truck Bay The truck bay is 67 feet long and 12 feet wide and is surrounded by the loading dock and walkway areas, which are 4 feet above the floor level of the truck bay. The roll-up door opening is 14 feet high by 11 feet 6 inches wide.

Above the east walkway is a leaded glass view port that allows containers in the sample vault to be inspected. Also located in the truck bay is the sump discharge station, a personnel decontamination shower, and a frisking station. A ladder with a locking hatch cover leads from the walkway to the maintenance area. In the northwest comer of the truck bay is an emergency exit leading directly to the outside ground level.

5.5.6.3 Maintenance Area The maintenance area is located east of the truck bay and serves as a work area and a shielding labyrinth. Housed there is the pump, the hydrogen purge station, the container decontamination spray system, and the swiper arm. A floor plug covers the sump drain valves and also serves as the sump lid.

Personnel access to the maintenance area is by way of a ladder extending from the truck by a walkway area. Access for containers is through an opening in the labyrinth west wall, 10 feet wide and covered with a sliding safety gate.

5.5.6.4 North Staging Area The north staging area for the high specific activity containers of solid radwaste, consists of the sample vaults, the main vault, and the floor staging area surrounding the vaults. Each sample vault is a separate cubicle with an individual lid. Access for containers is through an opening 11 feet wide in the labyrinth east wall. Personnel access to this area requires installation of a temporary ladder.

5.5.6.5 South Staging Area In the south staging area, roll-up door 8 feet wide by 11 feet 11 inches high opens into 3200 square feet of floor space designed to accommodate pallets of drums and LSA boxes of dry active waste (low specific activity). An emergency exit is located at the east wall. Outside the roll-up door is an equipment storage room and the forklift charging station. The south staging 5-7 Amended: June 2008 TL:

San Onofre Unit 1 DSAR RADIOACTIVE WASTE MANAGEMENT area is section lined to provide a method of accountability and location for the packaged solid radwaste awaiting shipment.

5.5.7 SHIPMENT Shipping casks and radwaste packages are used to transport the waste from the site to the burial ground. A contract trucking firm is hired to transport the shipping cask and radwaste packages to the burial site. Shipping casks waiting to be loaded are stored near the MPHF.

Depending on the activity level and waste classification, some of the dry active waste may be transported in a covered van or on a flat bed trailer without requiring placement in a shipping cask.

Intermodal containers and gondolas are used for shipping large components and bulk materials by rail.

5.5.8 DELETED 5.6 DELETED 5.6.1 DELETED 5.6.2 DELETED 5.6.3 DELETED 5.6.4 DELETED 5.6.5 DELETED TABLE 5-1 Deleted TABLE 5-2 Deleted 5-8 Amended: June 2008 TL:

San Onofre Unit 1 DSAR RADIOACTIVE WASTE MANAGEMENT TABLE 5-3 Deleted TABLE 5-4 (Deleted)

TABLE 5-5 Deleted 5 Amended: June 2008 TL:

San Onofre Unit I DSAR RADIATION PROTECTION 6.0 RADIATION PROTECTION 6.1 RADIATION PROTECTION PROGRAM This section contains information on the administration of the Health Physics Program for SONGS 1. The Health Physics Program is a site wide program for all three units at SONGS.

Following these sections is a brief description of the Radiological Environmental Monitoring Program.

The Radiation Protection Program ensures that personnel radiation exposure and, especially during emergencies, offsite doses are kept As Low As Reasonably Achievable (ALARA) and within regulatory guidelines.

The objectives of the Radiation Protection Program are:

(1)

To provide administrative control of persons on the site to ensure that personnel exposure to radiation and radioactive materials is within the guidelines of 10 CFR 20 and that such exposure is kept ALARA, (2)

To provide administrative control over station effluent releases to ensure that these releases are below 10 CFR 20 concentration values and that they do not exceed the dose values given in the ODCM, and (3)

To provide technical support during plant emergencies to limit any radiological consequences of those emergencies.

The radiation protection program in effect for SONGS 2 and 3 is the basis for the program at SONGS 1. The program is implemented by procedures to ensure compliance with all requirements and is reviewed and maintained by administrative controls required by the SONGS 10 CFR 50, Appendix B, Quality Assurance Program. Administrative controls include procedures for work planning, work control, access control, and waste shipment and disposal.

The Health Physics Division responsibilities are:

ED Establishing, implementing, and managing health physics/radiation protection programs and radioactive material control programs.

ED Providing technical assistance to the Station regarding radiation protection and radioactive material control.

E Reviewing and auditing radiation protection and radioactive material control programs and activities.

El Providing technical expertise regarding effects of radiation, shielding design, respiratory protection, whole body counting, personnel dosimetry, decontamination, solid radioactive waste processing, packaging, shipping and disposal, and assessment of radiation dose.

6-1 Amended: June 2008 TL:

San Onofre Unit 1 DSAR RADIATION PROTECTION Di Providing protection for all persons against ionizing radiation, supervising the contamination control and radioactive material handling programs.

El Ensuring that individuals are trained to the appropriate level in radiation safety.

Di Evaluating and reviewing the radiological status of the station.

Li Making recommendations for control or elimination of radiation hazards and controlling the radiation exposure of individuals to maintain exposures ALARA.

Li Procuring, calibrating, maintaining, and distributing portable radiation monitoring instruments.

EL Directing radiation control operations, determining acceptable personnel exposures, maintaining accurate dose records, and enforcing observance of radiation protection standards.

6.1.1 HEALTH PHYSICS DIVISION ORGANIZATION 6.1.1.1 The HP Division is organized into the following sections:

(1)

Radioactive Material Control (RMC) typically:

Receives radioactive material on site.

" Stores and controls radioactive material (excluding Special Nuclear Material) on site.

" Handles, packages and ships radioactive material off site.

" Implements the Process Control Program.

" Provides decontamination services.

Supplies protective clothing, portable ventilation and breathing air equipment.

(2)

HP Technical Support typically:

" Interprets regulations and develops procedures/programs.

" Provides technical support, for all aspects of the HP program.

6-2 Amended: June 2008 TL:

San Onofre Unit 1 DSAR RADIATION PROTECTION (3)

HP Operational Support typically:

a Performs surveys to evaluate radiological conditions.

Posts and barricades radiological areas.

0 Evaluates radiological hazards associated with working in radiological areas and implements controls sufficient to maintain exposures ALARA and control radioactive material.

W Provides monitoring for external and internal occupational radiation exposure during normal and emergency conditions.

0 Maintains at least 4 Emergency Plan qualified personnel on site (SONGS 1,2,3) at all times.

0 Determines prior occupational dose and maintains Administrative Dose Controls for occupationally exposed individuals.

0 Maintains occupational exposure records and provides occupational exposure reports.

E Provides support services as needed, including fit testing of radiological respirator devices and whole body counting.

(4)

Instrumentation typically:

" Maintains and calibrates HP instruments including survey instruments, contamination monitors, air samplers, continuous air monitors, and electronic dosimeters for normal and emergency conditions.

" Maintains radiological standards used in HP instrument calibration.

" Maintains custody and performs leak tests of sealed radioactive sources used by the HP, Chemistry and Maintenance Divisions.

" Evaluates and selects HP instruments used by the HP Program and Emergency Plan.

(5)

HP Self-Assessment Program

" Consists of several defined elements which are collectively used to improve divisional and Station radiation protection performance.

" Identifies and corrects deficiencies in radiological work practices and in the Health Physics Division programs.

6-3 Amended: June 2008 TL:

San Onofre Unit 1 DSAR RADIATION PROTECTION (6)

ALARA Program

" Facilitates ALARA Committee work and meetings.

" Tracks and reports radiation exposure status vs goals.

" Performs ALARA design reviews.

" Administers temporary shielding program.

" Reduces and trends source terms.

" Reviews and evaluates work plans, dose reduction techniques and equipment.

" Prescribes site ALARA training.

(7)

Unit 1 Decommissioning

" Provides radiological protection services to the Unit 1 Decommissioning Project including personnel dosimetry, respiratory protection, instrumentation, and operational health physics.

" Provides professional/technical radiological expertise to the Unit I Decommissioning Project.

" Processes classifies, packages, and ships radwaste for disposal.

" Administers the ALARA program for the Unit 1 Decommissioning Project.

" Develops methods and provides staffing to conduct radiological assessments of Unit 1 structures, components or similar media for the purposes of determining:

Feasibility of release to unrestricted use, Feasibility for remediation, Appropriate methods for demolition in radiological context, Environmental effluent controls necessary for contaminated structure/component demolition, Packaging requirements for demolished contaminated structures and components.

a Participates in project planning and administration for Unit 1 Decommissioning Project, including budgeting.

6-4 Amended: June 2008 TL:

San Onofre Unit 1 DSAR RADIATION PROTECTION Advises Unit 1 Decommissioning Project management and SONGS Procurement on technical matters regarding supplier selection.

6.1.2 RESPONSIBILITIES OF KEY PERSONNEL The Manager, Health Physics reports to the Station Manager and is responsible for developing, implementing, and managing HP programs for normal and emergency conditions for the site in accordance with ALARA and applicable standards and regulations.

The Supervisor of Radioactive Material Control (RMC) reports to the Manager, HP and is responsible for implementing the responsibilities of the RMC section.

The Supervisor, HP Technical Support reports to the HP Manager and is responsible for implementing the responsibilities of the HP Technical Support section.

The Supervisor, HP Operational Support reports to the Manager, HP and is responsible for implementing the responsibilities of HP Operations Support and Dosimetry.

The Supervisor, HP Instrumentation reports to the Manager, HP and is responsible for implementing the responsibilities of the HP Instrumentation section.

The Supervisor, Self Assessment reports to the Manager of Health Physics and is responsible for implementing the responsibilities of the Self Assessment Program.

The HP/LLRW Manager for Unit 1 Decommissioning is responsible for radiological work planning and production, and for ensuring that radioactive waste shipments meet all applicable transportation and packaging requirements.

The ALARA Supervisor reports to the Manager, HP and is responsible for implementing the ALARA program.

The Project Manager, Unit 1 Decommissioning reports to the Manager, HP and is responsible for implementing HP program requirements at Unit 1.

6.1.3 RADIATION PROTECTION TRAINING Each member of the permanent operating organization whose duties entail entering radiologically controlled areas or directing the activities of others who enter radiologically controlled areas, is instructed in the fundamentals of radiation protection, and must pass an examination before performing those functions. These same individuals are also required to attend a retraining program in radiation protection held at least annually.

The radiation protection training program includes instructions in applicable provisions of the NRC regulations for the protection of personnel from radiation and radioactive material (10 CFR

20) and instructions concerning prenatal radiation exposure (NRC Regulatory Guide 8.13).

6-5 Amended: June 2008 TL:

San Onofre Unit 1 DSAR RADIATION PROTECTION Health physics technicians also receive training in such areas as radiation and contamination surveys, air sampling techniques, use of portable and laboratory instrumentation, release limits, and safe handling of sources that apply to their specific job functions.

Other radiation training and retraining requirements are identified by health physics supervisory personnel to the Nuclear Training Division which develops and implements this training.

6.1.4 DELETED 6.1.5 PERSONNEL MONITORING DEVICES Station employees, contractors, support personnel, and visitors are generally required to wear personnel monitoring devices at all times while within the Radiologically Controlled Areas (RCA). Neutron badges are issued to those individuals subject to significant neutron exposure.

When issued, personal electronic dosimeters are read and recorded by automated computer controlled systems. In the event of a computer outage they are read and recorded by health physics personnel. TLDs may be processed in an on site National Voluntary Laboratory Accreditation Program (NVLAP) accredited laboratory, or sent to an off-site lab, at least quarterly or more frequently if necessary. Dosimeter and TLD badge readings are recorded by health physics personnel.

Whole body counting and bioassay are available to detect radioactivity within the body and to determine internal exposure levels. SCE normally takes an initial whole body count baseline measurement of individuals prior to their engaging in radiation work at SONGS. Additional measurements are taken whenever ingestion or inhalation of radioactive materials is suspected to have occurred. Each worker exiting the RCA is "passively" monitored for internal deposition when the worker uses the whole body frisking equipment (IPM8D or similar). When possible, a final whole body count is taken when the worker terminates radiation work at the site.

6.1.6 ACCESS TO RADIOLOGICALLY CONTROLLED AREAS Radiation Exposure Permits, (REPs) are a key administrative tool that informs workers of the radiological conditions in the work area and the requirements for protective clothing, respiratory protective equipment, dosimetry, and engineering controls. The REP is also used as an exposure tracking device to ensure that exposures are maintained ALARA.

Most entries into, and work performed in radiologically controlled areas require an REP. The radiologically controlled areas onsite are divided into areas of progressively more stringent access control, according to radiation and contamination levels. Controlling access to contaminated and radiation areas is accomplished by appropriate contamination and/or radiation caution signs, barricades, locked doors and gates, and may include audible and visual alarm signals.

SCE provides protective clothing, as necessary, to protect individuals against contact with radioactive contamination. Radiological respiratory equipment is available and its use is required when necessary, to protect individuals against airborne radioactive contamination. Individuals are trained in the use of respiratory protection equipment. The use and maintenance of protective 6-6 Amended: June 2008 TL:

San Onofre Unit 1 DSAR RADIATION PROTECTION clothing and radiological respiratory protective equipment is managed by the Health Physics Division.

Entry to radiologically controlled areas is normally through an access control point. Additional personnel monitoring devices, protective clothing, and respiratory equipment may also be issued here, if required. Radiation and high radiation areas are segregated within the radiologically controlled areas and identified and controlled in accordance with 10 CFR 20.1601. Positive control over high radiation areas having dose rates in excess of 1000 mrem/h is exercised by locked barriers. When it is not reasonable to construct a barrier, the area is roped off and either a health physics technician is in attendance or a flashing warning light is activated. Access to other high radiation areas (less than 1000 mrem/h) administratively requires the individual to use a dose rate instrument or an alarming dosimeter, or be accompanied by a health physics technician who performs dose rate surveys and who exercises positive control over the activities within the area. Control over entries into radiation areas is provided by using radiation exposure permits.

Entry to high radiation areas and maintenance work in radiation areas also requires a radiation exposurepermit.

6.1.7 RECORD KEEPING The Health Physics Division maintains an exposure record system which includes the exposure history and current exposure for individuals who enter radiologically controlled areas. This system contains all the information required to maintain NRC Form 4,_ Occupational Exposure History, and NRC Form 5, Individual Monitoring Results. The system produces Annual radiation exposure letters. The system also tracks daily exposures and provides radiological controlled area access control.

Proposed shipments of radioactive materials are reviewed to ensure conformance with 10 CFR 71, 61, and 49 CFR. The Health Physics Division maintains records of all shipments and stored wastes and submits reports to the NRC, as required.

6.1.8 RADIATION INSTRUMENTATION A variety of instruments are used to cover the range of radiation measurements at SONGS.

These include portable instruments as well as fixed systems. Portable instruments include low and high range beta-gamma survey meters, neutron survey meters, alpha survey instruments, and samplers for airborne gaseous and particulate radionuclides. Fixed systems include portal monitors and permanently installed area and process radiation monitoring systems.

Personnel contamination monitoring instruments are located at RCA exits. These instruments aid in preventing contamination from being spread into other areas. Appropriate monitoring instruments are available within the controlled areas. A portal monitor checks individuals as they leave the radiologically controlled area and again at the protected area exit.

Portable radiation survey and monitoring instruments for routine use are the responsibility of the Health Physics Division. Calibration sources are available to allow for instrument calibration, response checks, maintenance, and repair.

6-7 Amended: June 2008 TL:

San Onofre Unit 1 DSAR RADIATION PROTECTION 6.1.9 RADIATION SURVEYS Routine surveys are performed in accordance with the Health Physics program to ensure that licensed material is surveyed and inventoried in accordance with Federal regulations and the Technical Specifications. These surveys will include radiation and contamination surveys for radiation protection, updating posted areas, leak testing sources, and free release of plant equipment and surfaces. The frequency and extent of the surveys is in accordance with approved procedures and Federal regulations.

6.1.10 CONTAMINATION CONTROL Surveys are performed routinely to determine surface contamination levels. Additional surveys may be performed during and after maintenance work or after an operation that may have increased contamination levels. Any area found contaminated is roped off or otherwise delineated with a physical barrier, posted with appropriate signs, and decontaminated when practical. In areas where it is impractical to decontaminate the area to clean controlled area limits, a stepoff pad is used to prevent the spread of contamination.

Tools and equipment used in contaminated areas are monitored or bagged or both (or wrapped in polyethylene sheeting) before they are removed from the jobsite to prevent the spread of contamination. All tools and equipment being removed from the restricted area are monitored for contamination by health physics personnel (or other qualified personnel as specified in the station procedures) to ensure that they meet unrestricted area limits. If the tools or equipment do not meet the limits, they are decontaminated, disposed of as radioactive waste, or maintained for use within radiologically controlled areas only.

Regulated tools and equipment are items which, because of their design or use, are not considered practical to decontaminate. These tools and equipment are marked (by painting or otherwise) and are maintained for use within radiologically controlled areas.

Control of personnel contamination (external and internal) is provided using protective clothing, engineering controls, and respiratory equipment. Each individual is responsible for monitoring himself and his clothing when he crosses a local control point or the main access control point. If contamination is found, the individual is decontaminated, under the direction of health physics personnel.

Special coatings are applied to walls and floors of areas containing radioactive fluids. In addition, equipment vents and drains are piped directly to sumps (or other collection devices) where practicable to prevent radioactive fluids from flowing across the floor to the drains.

6.1.11 AIRBORNE ACTIVITY CONTROL Airborne contamination is minimized by keeping loose contamination levels low.

If personnel entry is required into areas where the source of airborne radioactivity cannot be removed or controlled, either occupancy is restricted and/or respiratory protection equipment is provided to maintain exposures within 10 CFR 20 limits. When required, an area is posted as an 6-8 Amended: June 2008 TL:

San Onofre Unit 1 DSAR RADIATION PROTECTION airborne radioactivity area and access is controlled. Entry into these areas requires the entrant to be on a radiation exposure permit. The use of a radiation exposure permit provides radiation exposure control by controlling and recording conditions under which work in airborne radioactivity areas is performed. Air sampling results are used to ensure that appropriate respiratory protective equipment is specified on the radiation exposure permit. The respiratory protection program is organized to conform with 10 CFR 20 requirements, Regulatory Guide 8.15, and NUREG 0041 recommendations.

The major portion of the respiratory equipment is available at the access control point(s).

Supplementary emergency respiratory equipment is available in the control room.

Whole-body counting, bioassay analysis, nasal smears, or face-piece interior smears may be performed to evaluate the protection afforded by respiratory protective equipment. To ensure an adequate program for respiratory protection, the program includes the following controls:

(1)

Each respirator user is advised that he/she may leave a high airborne-radioactivity area for psychological or physical relief from respirator use. Each user must leave the area in the case of respirator malfunction or any other condition that might cause reduction in the protection afforded the user.

(2)

Sufficient air samples are taken and surveys conducted to identify the hazard, evaluate individual exposures, and permit proper selection of respiratory protective equipment.

(3)

Written procedures are established to ensure respiratory equipment is properly selected and personnel using the equipment are supervised and trained.

(4)

Written procedures are established to ensure that respirators are individually and adequately fitted, and the respiratory protective equipment is individually tested for operability immediately before each use.

(5)

Written procedures are established to ensure that respiratory protective equipment is fully effective including procedures for cleaning and disinfection, decontamination, inspection, repair, and storage.

(6)

Written operational and administrative procedures are established for control, issuance, proper use, and return of respiratory protective equipment, including provisions for planned limitations or duration of respirator use for any individual, as necessitated by operational conditions.

(7)

Bioassays and other surveys are performed, as appropriate, to evaluate individual exposures and to assess the protection actually provided.

(8)

Records are maintained sufficient to permit periodic evaluation of the adequacy of the respiratory protection program.

6-9 Amended: June 2008 TL:

San Onofre Unit 1 DSAR RADIATION PROTECTION (9)

Before any individual is assigned to tasks requiring the use of respirators, it is determined that such an individual is medically and physically able to perform the work and use the respiratory protective equipment. A physician determines what health and physical conditions are pertinent. The medical status of each radiological respirator user is reviewed annually.

6.1.12 RADIATION PROTECTION FACILITIES Radiation Protection facilities include assess control locations, decontamination areas, radiation protection offices, locker rooms with shower facilities and toilets, and storage areas for protective clothing, respiratory protection equipment, and instrumentation for air sampling equipment, radiation detection, and personnel monitoring. Personnel monitor(s) and/or frisker(s) are normally located at the exit from the radiologically controlled areas.

6.1.12.1 South Yard Facility Equipment is staged in the South Yard Facility (SYF) for reuse in the Unit 1 Restricted Areas. In addition, this area is used to stage equipment expected to be free of contamination that is destined for unconditional release, until it can be surveyed and be proven free of licensed radioactive material contamination.

The facility consists of a fenced area and access to the area is strictly from the Owner Controlled Area. The SYF is controlled as a restricted area as defined in 10 CFR 20. The REMS Storage Area, the Multi-Purpose Handling Facility (MPHF), and the Hazardous Material (HazMat)

Staging Areas are included within this restricted area.

Stored items known to be contaminated with licensed radioactive material are tracked under the Radioactive Equipment and Materials System (REMS). These items are typically staged in containers or are covered, or staged inside buildings to protect them from the weather.

Radiological health and safety measures are instituted by the Health Physics Division to ensure protection against a release of licensed radioactive material.

The SYF has facilities for decontamination of tools and equipment and includes a CO 2 decontamination unit, a Plasblast unit and water, hot water and steam cleaning equipment.

6.1.12.2 Deleted 6.1.12.3 Multi-purpose Handling Facility (MPHF)

The Multi-purpose Handling Facility is located within the SYF yard area. The MPHF provides a staging facility for waste that has been processed and packaged and is awaiting shipment for disposal. Specific areas are set aside for segregation of waste based on the radioactivity content and the waste classification. A more extensive description of the MPHF can be found in DSAR Section 5.5.6.

6.1.12.4 Unit 1 Restricted Area 6-10 Amended: June 2008 TL:

San Onofre Unit 1 DSAR RADIATION PROTECTION As Decommissioning progresses, temporary radiologically controlled areas may be established, as needed, for work activities involving radioactive materials and/or systems. Work activities may include refurbishment of equipment, or segregation, decontamination, and/or packaging of materials, equipment, or solid waste. Calculation N-0320.007, "Airborne Source Term for South Yard Shops Facility and Outdoor Activities," Revision A, April 16, 1995, evaluated the work activities and established allowable contamination levels to ensure that the effluent limits of 10 CFR 20, Appendix B, will not be exceeded. Contamination control and effluent control measures are also implemented, as appropriate, to minimize worker exposure and the potential for an unmonitored effluent release. HP&E Position Paper "Airborne Effluent Controls During Decommissioning," dated September 27, 2000, provided additional guidance on effluent control measures to minimize airborne effluents.

6.1.12.5 Units 2&3 Truck Bay Areas in the Units 2&3 Protected Area adjacent to the Truck Bay access to the Units 2&3 Auxiliary Building are used as outdoor staging areas for potentially contaminated equipment and for waste segregation and packaging activities. A fenced area immediately adjacent to the Truck Bay access provides a designated area for these activities.

6.2 LOW AS REASONABLY ACHIEVABLE (ALARA) PROGRAM During Decommissioning, the site ALARA program in place during plant operation will continue to be maintained.

The ALARA methods, techniques, and practices implemented during Decommissioning will be the same as those used during plant operation. The existing ALARA program meets or exceeds the requirements of 10 CFR 20; Regulatory Guide 8.8, "Information Relevant to Ensuring that Occupational Radiation Exposures at Nuclear Power Stations Will Be As Low As Is Reasonably Achievable;" and Regulatory Guide 8.10, "Operating Philosophy for Maintaining Occupational Radiation Exposures As Low As Is Reasonably Achievable." The program ensures radiation exposure to workers and the public are maintained ALARA. SCE's commitment is stated in various station directives and implementing procedures. This is underscored by high level management oversight.

The Radiation Protection Program is the focal point of the ALARA program. Key elements of the ALARA program include dose reduction goal setting, in-depth radiation work review and job planning, industry experience review and implementation of beneficial technology and lessons learned from other nuclear sites.

6.2.1 GOALS Annual ALARA exposure goals are developed (by individual department) for the site. ALARA exposure estimates for work are tracked and evaluated as the work progresses. For work that requires ALARA job planning, a job specific file is compiled. Performance indicators are tracked and evaluated, including the ALARA exposure goals. The exposure is tracked and reported to management on a routine basis. Performance is measured against the goals. When 6-11 Amended: June 2008 TL:

San Onofre Unit 1 DSAR RADIATION PROTECTION the task is completed, the lessons learned are documented and reviewed with appropriate personnel. This review is included in the file for future reference.

6.2.2 TRAINING General Employee Training reinforces the ALARA program goals by providing methods for employees to keep their radiation exposure ALARA.

Practical factors in ALARA technique are examined during training. Mock-up training is performed for high dose jobs as a technique for reducing exposure.

6.2.3 ENGINEERING CONTROLS Engineering controls to reduce radiation exposures are considered during the ALARA planning effort. Engineering controls are used when beneficial in reducing exposures in a cost effective manner. Engineering controls are also evaluated during the project planning process.

Work enclosures and HEPA ventilation are available for use in controlling potential or actual areas of airborne radioactivity.

SCE evaluates and revises the ALARA program as appropriate. The program will continue to be implemented at SONGS I as it is at SONGS 2 and 3. Enhancements to the program will occur as industry experience grows and work techniques are developed or improved.

6.2.4 EFFLUENTS The Station Chemistry division has the responsibility to monitor gaseous and liquid effluent pathways. Monitoring of effluent pathways is specified the ODCM. The station policy is to maintain all effluent releases ALARA.

The effluent releases are compiled and reported in the Annual Effluent Release Report. This is in accordance with 10 CFR 20 and the reporting format of Regulatory Guide 1.21.

6.

2.5 REFERENCES

1.

S0123-VII-20, "Health Physics Program Description" 6.3 RADIOLOGICAL ENVIRONMENTAL MONITORING PROGRAM (REMP)

The REMP is designed to quantify ambient radiation levels in the environs of SONGS I and to identify and quantify concentrations of radioactivity, which have a potential exposure pathway to man, in various environmental media in the vicinity of SONGS 1. Sampled environmental media selection is based on the objectives stated below. Each sample is analyzed for both naturally occurring and SONGS-related radionuclides.

The objectives of the operational REMP are:

6-12 Amended: June 2008 TL:

San Onofre Unit I DSAR RADIATION PROTECTION (1)

To fulfill the obligation for radiological surveillance required by Offsite Dose Calculation Manual specifications, (2)

To determine whether there is any significant increase in the concentration of radionuclides in critical dose pathways, (3)

To detect any significant change in ambient gamma radiation levels, and (4)

To determine whether the operation of SONGS 1 has any measurable effects on the health and safety of the public or the environment.

The REMP is conducted in accordance with 6.8.4.b of the Permanently Defueled Technical Specifications and Section 5 of the ODCM.

6.3.1 EXPECTED BACKGROUND Results of the preoperational REMP are presented in section I of table 11.6-1. (See Rev. 3 of SONGS 1 UFSAR) The measurements were taken during the period from 1964 through 1967 to provide a baseline for future comparison. Because the number and type of samples collected during that time was limited, results of an expanded operational REMP from 1968 through 1987 for SONGS I have been included in section II of table 11.6-1 for general information.

6.3.1.1 Critical Pathways 6.3.1.1.1 Land Environment The only significant route of transfer of material from the plant to the land surrounding San Onofre is via stack releases. Under routine operating conditions, small quantities of noble gases, airborne tritium, particulate matter, and iodines were released through the plant vent stack. With all spent fuel transferred to the ISFSI, the source of noble gas and iodine from Unit 1 has been removed.

The predominant effect of the noble gases, on a person derives from the external radiation exposure they may contribute since as inert gases they cannot be concentrated in environmental media in the human food chain.

Since these gases constituted the major contribution of the plant to the environment, one facet of the REMP is intended to detect changes in environmental radiation levels attributed to this source. Because very low levels of radiation exposure were expected, the only detector of suitable reliability and sensitivity is one that integrates exposure over a long period of time.

Consequently, Thermoluminescent Dosimeters (TLDs) are being used at appropriate locations in the vicinity of SONGS 1. In order to provide adequate detection sensitivity, the TLDs are collected quarterly and annually from established REMP locations.

Internal exposure to radiation occurs from the ingestion or inhalation of radioactive materials.

Samples are still collected in the environment surrounding SONGS 1 and are subsequently analyzed for both naturally-occurring and station-related activity. For landward sectors, sampled 6-13 Amended: June 2008 TL:

San Onofre Unit 1 DSAR RADIATION PROTECTION environmental media include the following: air, local crops, and drinking water. Soil is also collected in order to detect any potential build-up of radionuclides in the land near SONGS 1.

Figures 5-1 through 5-4 of the ODCM show the sampling locations. Sample analyses include one or more of the following: gross alpha activity determination, gross beta activity determination, tritium activity determination, and radiostrontium activity determination, as well as the determination of the activities of various gamma emitters.

6.3.1.1.2 Marine Environment During normal operation of the plant, controlled quantities of radioactive liquids are released to the marine environment via the circulating water discharge. These discharges have been terminated from Unit 1.

As in the land environment, it is the intent of the monitoring program to use marine organisms as indicators of any accumulation processes occurring in the marine environment. For seaward sectors, sampled environmental media include the following: beach sand, ocean water, nonmigratory marine species, kelp, and ocean bottom sediment. Figures 5-1 through 5-4 of the ODCM show the sampling locations. Sample analyses are similar to those used in the analysis of terrestrial samples.

6.3.1.1.3 Exposure Estimates Offsite doses due to radioactive liquid and gaseous effluent are calculated as required by the SONGS I technical specifications. The methodology and parameters to be used in those calculations are described in the Offsite Dose Calculations Manual (ODCM). These evaluations are performed independently of the REMP.

6.3.1.2 Sampling Media, Location and Frequency Possible exposure to man could result from direct radiation, atmospheric immersion, inhalation, consumption of radionuclides deposited as particulates from the plant gaseous effluents, and consumption of radionuclides deposited in the marine environment by plant radioactive liquid effluents. In order to monitor the above pathways, various types of terrestrial and marine samples are collected and analyzed. Table 5-1 of the ODCM lists the required types of samples to be collected, the minimum number of locations, the frequency, and the type of analysis to be performed. Table 5-4 of the ODCM gives the sample collection points. These locations were selected to provide data from all landward sectors surrounding the plant, from major population centers, and to represent various food products that are produced in the area. In addition, several locations are selected in areas that would not be affected by plant operations to serve as control stations.

Direct radiation measurements are made at 45 locations using TLDs. Other sample types collected include air, soil, ocean water, drinking water, beach sand, local crops, marine animals, kelp, and ocean sediment. The selection of sample types is based on established critical pathways for the transfer of radionuclides through the environment to man, experience gained during the preoperational phase, and the evaluation of data during the operational phase.

6-14 Amended: June 2008 TL:

San Onofre Unit 1 DSAR RADIATION PROTECTION Sampling locations were determined with consideration given to site meteorology, local demographics, and land uses.

A land-use census is conducted annually and identifies the location of the nearest milk animal, the nearest residence, and the nearest garden of greater than 500 square feet producing fresh leafy vegetables in each of the 16 meteorological sectors within a distance of 5 miles of SONGS 1.

The land-use census is provided to ensure that the changes in the use of unrestricted areas are identified and that modifications to the monitoring program are made if required by the results of this census. Restricting the census to gardens of greater than 500 square feet provides assurance that significant exposure pathways via leafy vegetables will be identified and sampled since a garden of this size is the minimum required to produce the quantity (25 kg/year) of leafy vegetables assumed in Regulatory Guide 1.109 for consumption by a child. To determine this minimum garden size, it was assumed that: (1) 20% of the garden was used for growing broad 2

leaf vegetation (i.e., similar to lettuce and cabbage), and (2) the vegetation yield was 2 kg/mi 6.3.1.3 Analytical Sensitivity The types of radiological analysis performed on each sample are presented in the Offsite Dose Calculation Manual (ODCM) Table 5-1. The REMP emphasizes analysis for naturally occurring radionuclides, and for those radionuclides that may be attributable to the effluents from the facility and those that may be primary contributors to exposure of the public. In addition to gamma spectrometry, gross beta, gross alpha, radiostrontium, and tritium analyses are also performed on selected media as appropriate.

Maximum acceptable values for the lower limit of detection (LLD) for the various isotopes expected to be present in plant effluents are defined in the ODCM Table 5-3.

An interlaboratory comparison program is also required by SONGS I technical specifications.

Participation in this program ensures that independent checks on the precision and accuracy of the measurements of radioactive material in environmental sample matrices can be made. This is done as part of the quality assurance program for environmental monitoring to demonstrate that the results are reasonably valid. Analyses are performed on radioactive materials supplied as part of an interlaboratory comparison program.

6.3.1.4 Data Analysis and Presentation Information acquired from the environmental monitoring program fall into the following categories:

(1)

Radioactivity distributions in various environmental media at San Onofre, (2)

Direct radiation measurements in the vicinity of San Onofre, and (3)

Concentrations of radionuclides in crops and marine life that may result in a dose to a member of the public.

6-15 Amended: June 2008 TL:

San Onofre Unit 1 DSAR RADIATION PROTECTION In examining the distribution of radionuclides in the environment, comparisons are made of the preoperational data to determine if there are any biological or physical compartments in nature that are accumulating radioactivity.

Similarly, external radioactivity measurements for the operating plant are compared with the mean and range of data obtained in the preoperational program. Data from control locations that are considered to be outside of the area radiological impact of the plant are also compared with data collected near the plant.

For radionuclides found in foodstuffs, estimates of radiation dose are made that utilize the best estimates of food consumption. These dose calculations may then be compared with those based on plant emission data with the appropriate meteorological and aquatic dispersion models as discussed in the ODCM.

The data from the REMP are reported annually. The Annual Radiological Environmental Operating Report (AREOR) includes:

(1)

Summarized and tabulated results in the format of Regulatory Guide 4.8, December 1975 of all radiological environmental samples taken during the report

period, (2)

A summary description of the radiological environmental monitoring program, (3)

A map of all sampling locations, keyed to a table giving distances and direction from a site reference point, (4)

The results of licensee participation in the interlaboratory comparison program, (5)

Raw data and statistical summaries, interpretations, and analyses of trends of the results of the radiological environmental surveillance activities for the report

period, (6)

A comparison with preoperational studies, operational controls, and previous environmental surveillance reports, (7)

An assessment of the observed impacts of the plant operation on the environment, (8)

The results of the land-use census, (9)

A description of the reasons for not conducting the REMP as required, and the plans for preventing recurrence, (10)

A description of any exceedences of reporting levels listed in the ODCM Table 5-2, (11)

When analyses were not performed as required by the interlaboratory comparison program, a description of the corrective actions taken to prevent recurrence, 6-16 Amended: June 2008 TL:

San Onofre Unit I DSAR RADIATION PROTECTION (12)

And, if harmful effects or evidence of irreversible damage are detected by the REMP, the report also provides an analysis of the problem and a planned course of action to alleviate the problem.

(13)

Graphs to trend radioactivity concentration in different environmental media and its variation as a function of time.

6.3.1.5 Program Statistical Sensitivity The activity in environmental samples is expected to be low after radionuclides released by the power plant are diluted and dispersed. For many isotopes, the radioactivity is below the lower limits of detection (LLD) that are listed in the ODCM Table 5-3. Doses calculated from environmental measurements at the LLD demonstrate exposures below 5 mrem/yr. With exposures estimated from effluent data, much lower exposure levels can be demonstrated even though large errors may be introduced in the dispersion modeling. Thus, exposures evaluated using effluent data provide a more detailed definition of the dose increments due to the operation of SONGS 1 than exposure calculated from the environmental measurements.

Counting errors for effluent data and errors associated with the calculational models are used to determine the overall sensitivity of dose evaluation. Where dose calculations are based on environmental data, errors in the environmental sample analysis are included in the overall program sensitivity analysis.

6.

3.2 REFERENCES

1.

"Permanently Defueled Technical Specifications," Amendment No. 155 to License No.

DPR-13, Issued December 28, 1993

2.

"San Onofre Generating Station Unit 1, Updated Final Safety and Analysis Report,"

Docket 50-206 6-17 Amended: June 2008 TL:

San Onofre Unit 1 DSAR SITE CHARACTERIZATION 7.0 SITE CHARACTERIZATION (SECTION 7 HAS BEEN DELETED IN ITS ENTIRETY) 7-1 Amended: June 2008 TL:

San Onofre Unit 1 DSAR ACCIDENT ANALYSIS 8.0 ACCIDENT ANALYSIS

8.1 INTRODUCTION

Unit 1 was licensed to operate in consideration of a spectrum of postulated accidents with offsite dose consequences. Decommissioning activities are permitted by this same license and are predicated on the objective of posing no greater risk to the public than that which existed when the reactor was operating. The guidelines selected by Southern California Edison to evaluate risk during Decommissioning are based on the conservative assessment that postulated accidents from Decommissioning activities are moderately frequent events, as described in Regulatory Guide 1.70, Standard Format and Content of Safety Analysis Reports for Nuclear Power Plants (LWR Edition). The risk associated with an activity is acceptable if the potential accident dose consequences are a small fraction of the values established in 10 CFR Part 100, i.e., less than approximately 2.5 rem (whole body) and 30 rem (thyroid) for two-hour doses at the exclusion area boundary (EAB).

All spent fuel assemblies have been removed from the spent fuel pool and transferred to the ISFSI. The ability of the facility to withstand previously analyzed events such as natural phenomena and fires, is either unchanged from the previous operating plant licensing basis, or is improved in the defueled mode.

8.2 DELETED 8.2.1 DELETED 8.2.2 DELETED 8.2.3 DELETED 8.2.4 DELETED 8.2.5 DELETED 8.2.6 DELETED 8.3 LICENSING BASIS ACCIDENTS 8.3.1 REQUIREMENT FOR DECOMMISSIONING Unit I was licensed to operate in consideration of a spectrum of postulated accidents with offsite dose consequences. Decommissioning activities are permitted by this same license and are predicated on the objective of posing no greater risk to the public than that which existed when the reactor was operating. The guidelines selected by Southern California Edison to evaluate risk during Decommissioning are based on the conservative assessment that postulated accidents from Decommissioning activities are moderately frequent events, as described in Regulatory guide 1.70, Standard Format and Content of Safety Analysis Reports for Nuclear Power Plants (ILWR Edition). The risk associated with an activity is acceptable if the potential accident dose 8-1 Amended: June 2008 TL:

San Onofre Unit I DSAR ACCIDENT ANALYSIS consequences are a small fraction of the values established in 10 CFR Part 100, i.e., less than approximately 2.5 rem (whole body) and 30 rem (thyroid) for two-hour doses at the exclusion area boundary (EAB). (It should be noted that, due to the decay of fission product gases, the possibility of a significant thyroid dose no longer exists.)

The moderately frequent event is considered an appropriate and conservative guideline for evaluating Decommissioning accidents because:

1.

Decommissioning activities which have the potential to initiate an accident are carefully performed and controlled under existing site procedures and programs.

2.

Decommissioning activities are comparable to previously accepted activities which were part of the operating plant licensing basis, e.g., processing radioactively contaminated ion exchange resins, managing the risk of radioactive exposure with an ALARA program.

3.

The probabilities for specific accidents are low because the activities are performed infrequently.

8.3.2 EVALUATION OF ACCIDENTS DUE TO DECOMMISSIONING ACTIVITIES Decommissioning activities, including dismantlement, demolition and waste handling, are reviewed to determine if the potential exists for an accident that might result in an unplanned release of radioactive material. Where the possibility of a release does exist, the accident is evaluated to ensure that the estimated dose consequences are a small fraction of 10 CFR Part 100. Decommissioning activities readily meet the above criteria.

Descriptions of potential accidents and results of the accident analyses are documented in the 10 CFR 50.59 evaluations for the subject activities. The assumptions and limitations presented in the evaluations are part of the SONGS 1 licensing basis for Decommissioning. The analyses of specific Decommissioning accidents with dose consequences within the moderate frequency guidelines will not be added to the DSAR.

8.3.3 DELETED 8.3.3.1 DELETED 8.3.3.2 DELETED 8.3.3.3 DELETED 8.3.4 ACCIDENTS THAT ARE NO LONGER RELEVANT 8.3.4.1 Loss of Offsite Power (Loss of Spent Fuel Pool Cooling)

The Loss of Offsite Power (LOP) is no longer safety significant to the fuel storage facility since all fuel assemblies have been transferred to the ISFSI and the fuel storage facility has been 8-2 Amended: June 2008 TL:

San Onofre Unit I DSAR ACCIDENT ANALYSIS demolished. Loss of offsite power cannot affect radiological releases and need not be analyzed for consequences in accordance with the criteria of Regulatory Guide 1.70, Revision 3 8.3.4.1.1 DELETED 8.3.4.1.2 DELETED 8.3.4.2 Operating Basis Accidents Most of the accidents previously evaluated in UFSAR Chapter 15 for the operating plant were events that were directly related to power operation or the integrity of the reactor coolant system (RCS), such as turbine trip, loss of normal feedwater, rod ejection, fuel handling accident and steam generator tube rupture. Since the plant is permanently defueled and the RCS is demolished, such accidents are no longer applicable to Unit 1.

8.3.4.3 Fuel Handling Accident A Fuel Handling Accident (FHA) is no lohger credible since the spent fuel assemblies have been transferred to the ISFSI.

8.4 SUPPORTING CALCULATIONS AND STUDIES The following evaluations were performed:

DC-3779 Removal of CREATS from the Unit 1 Permanently Defueled Technical Specifications This evaluation determined the impact of not crediting the Control Room Emergency Air Treatment System (CREATS) with Unit 1 permanently defueled. Fuel Handling and SFP Loss of Cooling accidents (Unit 1), and the limiting Unit 2 radiological accident requiring site evacuation (LOCA), were considered. The results are no longer applicable as all spent fuel is stored in the ISFSI and the operational-period control room has been dismantled.

8.5 OTHER APPLICABLE EVENTS, NATURAL PHENOMENA, FIRES Other events, natural phenomena, and fires that were relevant during power operation are not significant for Decommissioning and dismantlement. Natural phenomena (earthquakes, floods, tornadoes, tornado missiles), and fires were considered under the operating license requirements and bound any activity under Decommissioning.

The probability and consequences of these events are either reduced during Decommissioning or remain unchanged from those that applied when the reactor was licensed to operate Equipment brought on site for dismantlement activities, such as cranes, hoists, or other heavy vehicles will be located and/or secured when required by procedures, or other evaluations, such that they cannot become missiles during a tornado event Fire protection for dismantlement 8-3 Amended: June 2008 TL:

San Onofre Unit 1 DSAR ACCIDENT ANALYSIS activities will be under the same administrative procedures and controls employed throughout the site for construction activities.

In summary, the safety significance of natural phenomena (earthquakes, floods, tornadoes, tornado missiles) and fires is either reduced during Decommissioning or remains unchanged from that which applied when the reactor was licensed to operate.

8.6 REFERENCES

1.

Letter, Michael K. Webb (NRC) to Harold B. Ray (SCE), "Issuance of Amendment No.

155 to Facility Operating License No. DPR-13, San Onofre Nuclear Generating Station, Unit No. 1, Permanently Defueled Technical Specifications (TAC No. M86377),"

December 28, 1993.

2.

Letter, Harold B. Ray (SCE) to NRC Document Control Desk," Docket No. 50-206, Amendment Application No. 211, Permanently Defueled Technical Specifications, San Onofre Nuclear Generating Station, SONGS 1," May 12, 1993.

3.

Letter, W. C. Marsh (SCE) to NRC Document Control Desk," Docket No. 50-206, Amendment Application No. 211, Supplement 1, Fuel Storage Facility Thermal and Structural Analyses, Permanently Defueled Technical Specifications, San Onofre Nuclear Generating Station, SONGS 1," June 30, 1993.

4.

Letter, W. C. Marsh (SCE) to NRC Document Control Desk, "Docket No. 50-206, Amendment Application No 211, Supplement 2, San Onofre Nuclear Generating Station, Unit 1", November 23, 1993.

5.

Letter, D. L. Zeiman (NRC) to R. Dietch (SCE) "Systematic Evaluation Program Topic XV-20, Radiological Consequences of Fuel Damaging Accidents Inside and Outside Containment," January 17, 1980.

8-4 Amended: June 2008 TL:

San Onofre Unit I DSAR ACCIDENT.ANALYSIS Table 8-1 (Deleted)

Table 8-2 (Deleted) 8-5 Amended: June 2008 TL:

APPENDIX B Fire Protection Design Basis Table San Onofre Nuclear Generating Station Unit I This section provided a comparison of the SONGS Unit 1 commitments to the requirements of Branch Technical Position 9.5-1, Appendix A. The information contained in this Appendix provided background information regarding statements made in the original Unit's 2 and 3 Fire Hazards Analysis, Unit I Fire Protection Program Review, and other selected Unit 1 Licensing Documents.

Unit 1 is no longer operating, there is no longer a need to comply with the requirements of 10CFR50, Appendix R, Sections III.G, 1I.J, III.L and IM1:O.

All safety related equipment and buildings have been removed. Fire protection features were systematically abandoned and removed as fire hazards were eliminated and buildings were demolished. The fire protection system has been reduced to manual suppression capabilities throughout the Unit 1 Industrial Area. All areas subject to the Branch Technical Position 9.5-1, Appendix A, have been decommissioned.

B-1 Amended: June 2008 TL:

APPENDIX A HISTORICAL INFORMATION Amended: June 2008 TL:

SAN ONOFRE UNIT 1 DSAR APPENDIX A HISTORICAL INFORMATION The following information, which previously appeared in the main body of the

DSAR, is designated as "historical" and is included in this appendix for the reader's convenience.

Originally provided as part of the licensing basis for the SONGS 1 operating plant, this appendix includes:

Information that is not expected to change Reference information which is a bounding (initial) condition for Decommissioning, and for which no updated values will be provided.

The paragraph numbers used previously in the main body of the Revision I of the DSAR have been preserved, with the addition of the prefix "A",

in this appendix.

Section A2.0 A2.1.2.2 Control of Activities Unrelated to Plant Operation The number and distribution of persons expected to be within the exclusion area as a result of the nearby beaches have been estimated by the consulting firm of Wilbur Smith and Associates, Inc.

(Table A2-1).

These estimates were developed by:

(1)

Determination of the nature, size, and location of facilities planned in the development of the San Onofre State Beach; (2)

Application of the standard rates of persons per camp site and persons per parking space as used by the Department of Parks and Recreation; and (3)

Distribution of persons from access points to the beach based upon a Poisson probability distribution function.

A2.1.3.1.1 Population The LPZ is contained entirely within the boundaries of Camp Pendleton.

The residential population is in the NW and NNW sectors and was estimated in 1976 to number approximately 1127(4',6 increasing to 1201 by 1980 and remaining at that level.{6 }

An elementary school for the residents of this military housing development is also located within the LPZ.

REFERENCES:

4.

San Diego Association of Governments, "Final Series V Population Projections,"

San Diego, California.

6.

Joint Public Affairs Office, U.S. Marine Corps Base, Camp Pendleton, California.

A-1 Amended: June 2008 TL:

SAN ONOFRE UNIT 1 DSAR APPENDIX A HISTORICAL INFORMATION A2.1.3.1.2 Population in the Vicinity of the LPZ Beyond the LPZ there are three Marine base camps within a distance of 5 miles from the plant site.

Camp San Onofre has a population of 4,804 and is located 2.5 miles from the site in the northeast sector, Camp San Mateo has a population of 2,564 and is located 3.5 miles from the plant site in the north sector, and Camp Horno has a population of 2,426 and is located 4.5 miles from the plant in the east sector.

)

6)

Within the LPZ the transient population generators within the LPZ are San Onofre State Beach and Interstate 5.

Camp Pendleton is not considered a transient population generator within the LPZ inasmuch as the main centers of activity on the base are between 10 and 20 miles from the plant.

The peak seasonal transient population is projected to increase from 1,813,000 in 1980 to 3,123,700 in 2020.

The peak daily population is estimated to expand from 95,100 in 1980 to 164,600 in 2020.

REFERENCE:

6.

Joint Public Affairs Office, U.S. Marine Corps Base, Camp Pendleton, California.

A2.2 HYDROLOGY Notable hydrologic influences on the site are the Pacific Ocean and a small area of foothills which drain toward the site.

The streams and drainage-ways nearest SONGS are intermittent, carrying water primarily in the wetter months.

The largest nearby streams are San Mateo Creek, two miles to the northwest, and San Onofre Creek, about one mile to the northwest.

San Onofre Creek has a drainage area of approximately 43 square miles.

The drainage basin is approximately 9.7 miles long and 4.7 miles wide.

The origin of the basin is in the Santa Margarita Mountains to the northeast of the site.

The maximum elevation in the basin is 3187 feet above sea level, mean lower low water (mllw),

with the minimum at sea level.

The San Mateo Creek drains an area of approximately 132 square miles.

There are two U.

S.

Geological Survey stream-gauge stations on San Mateo Creek and two on San Onofre Creek.

Measurable flows occur only four or five months of the year, usually from December through April.

Surface runoff on the San Onofre Creek basin is used by the Camp Pendleton Marine Corps Base to recharge the base well system.

There are no other surface water users in the watershed.

Groundwater contours of the San Onofre Creek basin indicate that groundwater movement is to the west and southwest toward the ocean.

Little groundwater movement has been identified to occur between the San Onofre Creek and the San Mateo Creek groundwater basins.

A-2 Amended: June 2008 TL:

SAN ONOFRE UNIT 1 DSAR APPENDIX A HISTORICAL INFORMATION Before SONGS was constructed, about 120 acres of the foothill area east of the plant drained through the plant site.

Runoff from this watershed is now intercepted by a drainage system along the northeast side of the San Diego Freeway and carried northwest away from the plant to be discharged into the ocean near Basilone Road.

The earthen channel on the northeast side of the San Diego Freeway has a capacity of 1850 cubic feet per second.

A pair of concrete culverts that lead under the freeway are maintained by the California State Department of Transportation.

The culverts are 42 and 72 inches in diameter with flow capacities of 180 and 520 cubic feet per second, respectively.

San Diego Bay is the site of the tidal reference station nearest to the SONGS plant.

The differing locations of the tidal reference station and the SONGS plant (on a bay and the open coast, respectively) necessitate application of an amplitude ratio of 0.92 to the San Diego data.

The highest tide observed at the reference station occurred on December 20,

1968, and the lowest on December 17, 1933.

The water levels of these tidal extremes, adjusted to San Onofre, are +7.18 feet and -2.66 feet mllw, respectively.

The prevailing regional ocean current, called the California current, is about 600 miles wide and meanders slowly southward along the coast.

From late October or early November until February or March, it is replaced by the northwest flowing Davidson current.

The two currents determine the physical and chemical properties of the water near the SONGS shore.

Frequently, a meander or eddy from one of the two regional currents induces a current at the San Onofre site, which may dominate tides and wind currents for up to two weeks.

A2.3 METEOROLOGY This section presents the meteorological description of the site and its environs.

Those meteorological factors which bear upon plant design, operation, and safety are presented and discussed.

Meteorology and Climatology Due to its coastal location, the site climate can be characterized as marine, subject to daily land and sea breezes on which an annual monsoon oscillation is superimposed.

During most of the year, daytime heating of the land surface makes the land warm relative to the Pacific Ocean.

This thermal difference produces an onshore wind (sea breeze) that normally begins shortly after sunrise and lasts until after sunset.

At night, the land cools, reversing the thermal gradient, and an offshore wind (land breeze) develops.

This diurnal reversal is most apparent during the spring and fall months.

A-3 Amended: June 2008 TL:

SAN ONOFRE UNIT I DSAR APPENDIX A HISTORICAL INFORMATION Winds at the site exhibit an onshore component somewhat more than half the time.

The most frequent wind is the WSW-WNW sea breeze, which averages about 6 to 7 miles/hour.

Winds associated with frontal passages are generally out of the southwest and relatively stronger, frequently over 10 miles/hour.

The strongest winds blow out of the northeast, occasionally exceeding 30 to 50 miles/hour, and are associated with Santa Ana conditions.

The warm dry Santa Ana winds result from a relatively strong offshore pressure gradient produced by the Great Basin high pressure cell in winter months between storm passages.

The Pacific Ocean has a moderating influence over the temperatures in the site region.

The daily temperature ranges are usually less than 15 F in the spring and summer, and about 20 F during the fall and winter.

Temperatures below 40 F are rare.

Temperatures above 85 F occur occasionally throughout most of the year when air from the interior reaches the coast.

The average relative humidity ranges from about 60% during the day to about 75% at night.

Occasionally, however, during Santa Ana conditions, the influx of the dry desert air can drop humidities in the area to less than 10%.

The normal annual precipitation for San Diego and Los Angeles is 9.45 inches and 11.59 inches, respectively.

Laguna Beach, 17 miles north of the site, with a surrounding topography similar to San Onofre, has a normal annual precipitation of 11.75 inches.

About 85% of the precipitation falls in the winter months of November through March during the passage of migratory storm systems, with measurable rain falling on an average of one day in four.

Occasionally, a wet month occurs, such as during one February when 11 inches of rain fell in Los Angeles.

A maximum rainfall of 6.19 inches of rain in 24 hours2.777778e-4 days <br />0.00667 hours <br />3.968254e-5 weeks <br />9.132e-6 months <br /> was recorded in Los Angeles.

Measurable snow has not been recorded at a coastal location in Southern California.

A2.3.1 General Meteorological Conditions for Design and Operating Bases A2.3.1.1 Temperature The average annual temperature for the Camp Pendleton Marine Corps surf and weather station nearby is about 60 F, average maximum in July 72 F, average minimum in February 42 F.

The highest recorded was 97 F, the lowest 25 F (see Table A2-2).

With respect to the absolute maximum it is likely that in a longer record the value would be considerably exceeded; one might expect that occasionally the temperature at the site will reach 100 F or more in extreme Santa Ana conditions.

But these very hot days (and also the cool days with temperatures in the twenties) are quite unusual, and the normal daily temperatures ranging from a low of about 40 F to a high of about 60 F in winter and from 60 F to 72 F in summer will be deviated from only slightly on most days.

A-4 Amended: June 2008 TL:

SAN ONOFRE UNIT 1 DSAR APPENDIX A HISTORICAL INFORMATION A2,3.1.2 Precipitation The precipitation, about 12 inches a year, occurs mostly in winter:

the total for the months of May through September averages less than one-half inch.

The rainiest month is January, with an average of more than 3 inche's; the driest is July, with an average of 0.04 inch.

The total number of days per year with measurable precipitation averages only about 40.

A2.3.1.3 Wind and Stability at the Plant Site The data and information contained in this section and as referenced were developed and verified for the SONGS site original design and licensing.

A general review has determined that this information, its basis, and its impact to the facility design have not changed since the plant was licensed.

Meteorological data currently in use for dispersion factors for SONGS 1 was obtained from 1979 -1983 and is incorporated in Table A2-7.

This table shows the annual, joint frequency, wind speed-direction summaries, stratified by Pasquill stability categories.

The strong dependence of stability categories to onshore and offshore wind flow is indicated in Table A2-3.

The unstable categories A, B,

and C occur principally with onshore flow.

The stable categories F and G are associated principally with offshore flow.

The average wind speeds for the categories A through E for both onshore and offshore flow are nearly equal, i.e.,

3 m/s.

However, for the stable categories F and G, there is an increasing tendency for the offshore flow to be stronger than onshore flow by 1 to 2 m/s.

Long-term (10 years) annual joint frequency wind speed-direction summaries stratified by Pasquill stability are presented in Table A2-4 for San Diego (Lindbergh Field) and for Los Angeles (Los Angeles International Airport).

The stability categories were determined by the NWS STAR program and were obtained from the Environmental Data Service of the National Oceanic and Atmospheric Administration.

The long-term tables from the STAR program are based on 24 observations a day, while the short-term STAR tables are based on eight observations a day.

The short-term tables concur with the first 2 years of the SONGS data.

A comparison of the frequency distribution of stability categories between the SONGS meteorological tower measurements and those obtained by the STAR model for Los7 Angeles and San Diego is shown in Table A2-5.

The unstable category (A + B + C) frequencies from the tower are about 10% higher and the stable category frequencies (F + G) about 10% lower than those obtained from the STAR model.

The neutral (D + E) category frequencies, however, are in closer agreement.

A-5 Amended: June 2008 TL:

SAN ONOFRE UNIT 1 DSAR APPENDIX A HISTORICAL INFORMATION These differences in the unstable category frequencies stem from two factors. The first is related to the fact that the STAR model tends to underestimate the frequency of unstable hours and overestimate the neutral and stable hours.

The second factor is the passage of air over progressively warmer water as it moves toward the coast.

During the summer months the water surface temperature gradient, over which the air

moves, reaches a maximum of about 40'C per 180 kilometers (112 miles).

Because frictional stresses over the water are a minimum, very little mechanical turbulence occurs.

This permits the lapse rates in the.lower levels to become superadiabatic

(< -9.8 C per kilometer) by the time the air reaches the coastline.

The STAR model does not consider this type of phenomenon and consequently will underestimate the instability frequencies as well as the magnitude of the instability.

Smith, (14) in a

comparison of STAR model results with tower measurements at New Orleans, Louisiana; and Wilmington,

Delaware, and vicinity, showed the results given in Table A2-6.

Section A5.0 A5.1 SOURCE TERMS The source term information provided in previous revisions of the FSAR in this section was based on operational conditions.

Since the RCS has been drained and fuel has been removed, these source terms are extremely conservative.

With the cessation of operations the source for generation of fission product gasses, such as krypton and xenon has been removed.

Sufficient time has passed to eliminate these nuclides as a concern.

With the majority of systems drained, the current source term is almost exclusively located within the spent fuel pool.

A5.1.1 SPENT FUEL ACTIVITY The estimates of fission product volatile activity and noble gas inventory due to a gap release are extremely conservative.

The spent fuel in the pool has been out of the reactor vessel since March 1993.

The estimates represent a conservative maximum condition, and therefore have not been recalculated for the present time.

These estimates bound the current conditions and are were well within the regulatory limits.

The potential for the release of fission product volatile

activity, contained in the pellet-cladding gap region for an irradiated fuel
assembly, is calculated from FIPCO-2 results for fuel which has undergone the maximum design burnup.

It was assumed that a decay period of 90 hours0.00104 days <br />0.025 hours <br />1.488095e-4 weeks <br />3.4245e-5 months <br /> elapsed in the process of shutting down the reactor, removing the head, and transferring the first fuel assembly to the spent fuel building.

A-6 Amended: June 2008 TL:

SAN ONOFRE UNIT 1 DSAR APPENDIX A HISTORICAL INFORMATION The gap inventory of noble gas isotopes is listed in Table A5-1 on a per-megawatt basis.

The potential release, in the event of a fuel cladding failure, would have been obtained by multiplyihg the table value by the thermal power rating of the involved fuel elements.

Nongaseous isotopes were excluded because of their essentially complete retention by the fuel and cladding at the low temperatures of the spent fuel pit and the scrubbing effect of the fuel pool water should a release occur.

A5.1.2 CORROSION PRODUCT ACTIVITIES AND DEPOSITED CORROSION PRODUCTS Corrosion product activities during power operation were calculated by the digital code CORA.

This code computes the concentration of active nuclides formed by neutron irradiation and subsequent exchange of core-deposited crud with that in suspension.

Removal by purification, deposition, and decay are taken into account.

Tables A5-2 and A5-3 give the maximum concentrations and total system inventories of the significant fission and corrosion products, expressed in terms of isotopic quantities and as photon energy groups for direct gamma source application.

The tables are based on a maximum power rating of 1,347 MWt, and a fuel element cladding reference defect of 1%

for the fission products.

The current source term is far reduced from these estimates, however theses tables are included as a "worst case" basis.

A5.1.3 AUXILIARY SYSTEMS ACTIVITY The auxiliary systems that connected with the primary plant systems have, for the most part, been drained and vented under SAFSTOR.

The waste gas decay tanks have been vented and purged.

The only significant sources of activity remaining are the fuel assemblies which are stored in the spent fuel building.

A5.1.4 TRITIUM ACTIVITY IN THE REACTOR COOLANT

)

The reactor coolant system has been drained and there is no longer any tritium produced by the SONGS 1 core.

The analysis below was performed for power operation and explains why SONGS 1 continues to release small amounts of tritium in the liquid effluent stream.

The record of actual releases is contained in the Semi-Annual (or Annual) Radioactive Effluent Release Report.

A-7 Amended: June 2008 TL:

SAN ONOFRE UNIT 1 DSAR APPENDIX A HISTORICAL INFORMATION One tritium atom is formed as a ternary fission product for each 12,500 fissions (fission yield = 0.008%).

For a reactor of the size of SONGS 1, this represented a tritium inventory of slightly less than 5,000 curies a year.

Indications are that about one-half of this tritium can diffuse through the fuel and through the stainless cladding into the reactor coolant.

There is no economically practical way to remove this activity once it gets into the reactor coolant water.

The problem has been examined for SONGS I and the consequences of tritium release do not appear to constitute a hazard.

The effect of tritium on the maximum ground concentration of gaseous activity released at the vent stack was examined first.

The conservative assumption was made that the entire 5,000 curies of tritium would appear with the waste gases.

Calculation shows that yearly average vent stack gas activity due to tritium will be only 9.5 x 10-'

Ci/s, and maximum ground concentration of tritium with a vent stack dilution factor of 1.3 x 10-' s/m3 will be only 2.1 x 10-1 pCi/cm3 air.

Maximum permissible concentration in air for tritium is 2.0 x 10-'

pCi/cm3 of air in unrestricted areas (see Appendix B of 10 CFR 20).

Alternately, it was conservatively assumed that 100% of the total tritium would be in liquid wastes and would be discharged with the plant liquid effluent. Calculations show that this will raise the activity of the 350,000 gal/min effluent by 7.3 x 10-6 pCi/ml.

Unrestricted maximum permissible concentration in water for tritium is 3.0 x 10-' PCi/ml (see Appendix B of 10 CFR 20).

Thus, it can be seen that whether the tritium goes into the liquid effluent or into the vent stack discharge, the maximum concentration of tritium in the unrestricted environment is several orders of magnitude below the allowable concentrations set forth in 10 CFR 20.

The quantities of tritium discharged from the SONGS 1 facility are presented in the semiannual effluent reports. 4(

REFERENCE

4.

San Onofre Nuclear Generating Station Radioactive Annual Effluent Release Report, June 1996.

A5.1.8 OPERATIONAL EXPERIENCE Releases of radioactive nuclides in either liquid or gaseous wastes discharged from the plant have been a small fraction of the quantity permitted under 10 CFR 20.

Table A5-4 presents a summary of the liquid and gaseous waste discharges from the plant from 1968 through 1996.)(

These quantities indicate that the actual radioactivity of the reactor coolant during plant operation was less than the predicted quantities for which the waste management system was designed.

Fuel cladding leakage and steam generator tube leakage occasionally resulted in higher than normal discharges from the plant; however discharges remained well below the limits specified in 10 CFR 20.

The quantities of radioactive nuclides discharged from the SONGS 1 facility are presented in the Annual Radioactive Effluent Release Reports. 4" A-8 Amended: June 2008 TL:

SAN ONOFRE UNIT 1 DSAR APPENDIX A HISTORICAL INFORMATION The historical information presented in Table A5-4 is a conservative boundary estimate of the radioactive inventory in the reactor coolant system, since the RCS has been drained for SAFSTOR.

Since the plant ceased commercial operation, the activity in the spent fuel pool has remained relatively constant, changing only in response to being placed on recirculation through an ion exchanger. Typical isotopic activity as determined by analysis is provided in Table A5-5.

Airborne releases to the environment are due to passive venting of containment and diffusion of small quantities of noble gases from the spent fuel rods.

Once the plant was retired, discharges of noble gases, iodine, and particulate decreased dramatically; releases of tritium originate in the fuel handling building and occasionally are detected at the level of sensitivity for the analytical technique.

REFERENCES

4.

San Onofre Nuclear Generating Station Radioactive Annual Effluent Release Report, June 1996.

5.

San Onofre Monthly Operating Reports, December 1969, January 1970, January-March 1971, June-September 1971, November 1971.

A5.2.4 Estimated (Liquid) Releases Estimated volumes of radioactive waste processed during plant operation and the assumptions on which these estimates are based are listed for SONGS 1 as an operating plant in Table A5-6.

These estimates are very conservative as the volume of releases during SAFSTOR is substantially less.

A-9 Amended: June 2008 TL:

SAN ONOFRE UNIT 1 DSAR APPENDIX A HISTORICAL INFORMATION TABLE A2-1 ESTIMATES OF THE NUMBER OF PERSONS PRESENT IN THE BEACH ZONE OF THE EXCLUSION AREA' Maximum Use Exclusion Area Walkway and barranca area Full Development of Facilities 25 Current Facilities

. 9 Averaze Use Current Facilities 2

Beach (below mhw line) 75 26 and adjacent water TOTAL 100 35 Excludes traverses of highway, rail, and waterway.

5 7

A-10 Amended: June 2008 TL:

SAN ONOFRE UNIT 1 DSAR APPENDIX A HISTORICAL INFORMATION TABLE A2-2 Month January February March April May June July August September October November December Av 5:

5.

5 5

5 6

6 6

6 6

5 5

MONTHLY TEMPERATURES AT CAMP PENDLETON SURF Temperatures, Avg.

erage Max.

Max.

2.8 97 60 3.5 88 62 6.5 77 60 7.9 75 63 9.8 89 65 3.9 93 67 7.5 78 72 7.5 86 72 5.6 92 72 2.0 97 68 8.7 87 68 4.6 88 63 Avg.

44 40 44 51 52 57 62 61 58 54 48 43 AND PRECIPITATION AND WEATHER STATION OF 25 31 36 38 40 44 52 52 44 40 35 25 Preci itatign inches 3.14 2.20 2.00 0.87 0.14 0.09 0.04 0.09 0.10 0.47 1.06 1.93 A-lI Amended: June 2008 TL:

SAN ONOFRE UNIT I DSAR APEND'DI, A

HISTORICAL IN FOR=T ION TABLE A2-3 ANNUAL WIND CHARACTERISTICS A1ND PASQUZLL STABILITY CATEGORIES (January 25, 1973-January 24, 1976)

LOWER LEVEL (10 metersl stability Catelory A

B C

D F

Percent Frrocuency 26.75 3.10 3.96 21.73 17.76 8.41 18.28 Onshore Wind Average Frequency Speed

(%I LMsl 91.5 3.5 78.7 3.0 74.0 3.0 67.1 3.3 47.5 3.2 20.6 2.3 9.1 1.8 Offshore wind Average Frequency speed 8.5 4.0 21.3 2.8 26.0 2.9 32.9 2.7 52.5 2.8 79.4 2.7 90.9 3.7 "PER LEVEL 136 A

B C

D E

F 6m anrd 29.28 3.26 4.36 22.91 15.56 8.07 16.57 40m Combined) 94.3 81.0 76.4 66.4 48.3 26.4 14.7 3.6 3.1 3.1 3.3 3.5 1.9 1.7 5.7 19.0 23.6 33.6 51.7 73.6 85.3 3.9 3.2 3.2 2.8 2.8 2.5

2.7 Amended

June 2008 TL:

SAN ONOFRE UNIT 1 DSAR APPENDIX A HISTORICAL INFORMATION TABLE A2-4 ANNUAL LONG-TERM (10 YEARS)

AND SHORT-TERM (2 YEARS)

DISTRIBUTION OF PASQUZILL STABILITY CATEGORY (STAR)

AND AVERAGE WIND SPEED January 1955-December 1964 January 1973-December 1974 stability Category Percent Preauency Average Wind speed MLI/S) percent Precuency Average Wind speed fm/sl Los Angeles, California A

B C

D E

F G

0.34 6.51 14.43 21.63 22.00 11.04 24.05 0.8 2.7 4.2 4.8 3.4 3.5 1.6 0.07 6.42 13.66 22.48 23.82 9.93 23.61 2.0 2.8 4.3 4.4 3.3 3.4 San Diego. california A

a 0.26 9.06 2.2 2.9 0.17 6.32 1.4 3.1 A-13 Amended: June 2008 TL:

SAN ONOFRE UNIT I

DSAR APPENDIX A HISTORICAL INFORMATION TABLE A2-5 COMPARISON OF DISTRIBUTION OF STAR STABILITY CLASSIFICATIONS AT LOS ANGELES AND SAN DIEGO WITS SAN ONOFRE TOWER STABIIT MEASUREMENTS (Percent Frequency of occurrence)

(A + B + C1 Unstable Los Anaeles San onofre January 1955-December 1964 January 1973-December 1974 Jan, 25, 1973-Jan. 24, 1976 21.3 20.2 25.8 19.9 Lower' 33.8 Upper-36.9 (D + Ei *Neutral January 1955-December 1964 January 1973-December 1974 Jan. 25, 1973-Jan. 24, 1976 43.6 46.3 39.8 49.3 Lower-39.5 Upper-38.5 (F + GI Stable January 1955-December 1964 January 1973-December 1974 Jan. 25, 1973-Jan. 24, 1976 35.1 33.5 34.4 30.9 Lower-26.7 Upper-24.6 Based on stability joint frequency wind speed-wind direction summaries.

Lower wind level 10m, upper wind level 36.6m and 40m combined.

A-14 Amended: June 2008 TL:

SAN ONOFRE UNIT 1 DSAR APPENDIX A HISTORICAL INFORMATION TABLE A2-6 STAB ILITZY FASURZENTS (Percent Frequency of Occurrence)

Heasurements Location Model/Tower Unstable Neutral Stable New Orleans, STAR 25 36 39 Louisiana Tower 82 6

12 wilmington, STAR 16 51 33 Delaware and Tower (Delaware city, DE) 68 s

27 Vicinity Tower (Salem, NJ) 65 13 22 A-15 Amended: June 2008 TL:

SAN ONOFRE UNIT 1 DSAR APSPENDIX. A HISTORICAL I NFORM3AT ION, Table A2-7-!

RIJIl 0A!£1 01/07601 17Skiff3 C"Ui9jtR3 Cauf -

X005203.

VERSION 2.0 SAN1 (Al401401Ton 1 79-83 ET CgOI,li PE5EIASE; 03E-SFECIIIC 1000. 010363.

JOJINT FREQUE14CY DISTRIBUTION4 OF MIND4 SPEED AMD DIRSECTION*

AT510PHEUIC Sl'ABIL3¥ CLASS A IJOSX lI/39 0.12 0.45 0.099 1,34 2.24 Z,66 5.13 3.14 4.0t 4.92 TOTAL N

0.0 0.0 0.0 0.0 O,. 007 0.007 0.0 0.007 0.007 0.0023 0.03 tWNE D.0 0.0 0.0 0,0 0.000 0.002 0.005 0,007 0.009 0.0 0.028 D.06 tie 0.0 0.00 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.00 0.0029 a,009 0.0 1 EN0E 0.0 3.0 0.0 0.0 0.0 0.00 0.0 3.0 0,0

0. 022 0.0 0.00 0.03 E

E5E 0.0 0.0 0.0 0.0 a.0 0.0 0.0 0.0 0.0 0.0 0.0 0.005 0.0 0.0 0.00a 0.002 0.0 0.006 0.0 0.002 0.0 0.002 0.002 0.014 0.00 0.01 SE 0.0 0.0 n.O 0.0 0.002 0.009 0.012 0.031

a. 031 0.012 0.061 0.20 SSE 0.0 2.0 0.a 0.0 0.070 0.080 0,162 0.143 G.136 0.12S 0.247 1.01 00 0.0 0.0 0.02 0.000 0.270 0.209 0.400 0.294*

0.108 0.172 0.200 2.38 3154 0.0 0.0 C0A 0.049 0o. z77 (1.503 0.130 a.465 0.334 0,.07 1.01 SI' 0.0 0,0o 0.769 0,037 0,51o 0.289 0.110 0.05N 0.69 a.-7l5 0.915 0.0 0.0 0.006 0.019

3. 270 0.,740 1.267 0.077 0.550 0.144 0.[000 0.0610 5.03 H

0.000 0.035 0.0 0.019 0.106 V. son I1.094 1.753 1.61S 1,236 0.66S 0.249 0.204*

7.00 tea4 0.0 0.0 0.0 0.007 0.026 0.096 0.190 0.9*6 0.u39 0.009 0.4146

0.

6i 3.16 054H 0.0 0.0

,0.

,0.

0.036 0.026 0.071 0.4l5) 0.020 0.009

0. 026 0.725 0.0 0.0 0.0 43.009
0. 009 0.007 0.007 0.0O04 0.009 0.021

[}.016 0.0*0 0.10 C:

01

,0.

0.0 0.01 0.007 0.0

0. OOZ 0.005 D.005 0.0*2 0.0 0.365 0.002 0.009 40.0 O,0 0,0 0.0 0.002 0.0 0.0 0.0 0.0 0.0 0.o02 0.002 0.02 00,4 0.0 0.0Z 0.0 0.002 0.00 3 0.0 A. 05 0.0 0.0 0.0 0.0 0.0 0.0 0.01 JOINT4 FREQ14CYi~ D25TR180112W4 OF HIND0 SPEED AND DIRECTION AIKOSPHERIC STABILITY CLASS 0 TOV*A L 01003 0.000 0,005 0.007 0.167 1.309
2. W64 6.301 5.00 1 4.673 3.441 2.165 1.O60
1. SIB 06.54 IOTAL 0.0 0.3 0.0 0.06&

0.205s 0.310 0.219 0.210 0,17Z 0.127 0,001 0.060 0., 0; 1.?Z L0/AX IO/S I 0.2 Z 0.45 0.89 1.19 1.27 2.0 1.68 3.10 3.50 4.02 4*.47

'.92 7.15 1TOAL 14 14110 45 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.3 0,0 0.0 0.0 0.0}

0.0 0,0 0.0 0.305 W.ant 0.0 0.0 0.005 0,0 0.0 0.02 0.3 0.D 0.00S 0.0 0.005

0. OZ 0.0 0.0 0.0 0.0 0.0 0.Ooz O.Oz 0.0 0.005 0.002 0.01 0.02 0:00 E0433 0.0 0.0 0.0

.0.

0.0 0.0 0.0 0.0 0.002 3.0 0,000 0.0

-0.

0.01 0.0 0.0 0.0 O.0 0.0 0.0 3.0 0.0 0.0 0.0 0.0 0.0 0.0

.. 0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.005 0.0 0.002 0.a00 0.009 0.00 0.02 SE 0.0 0.0 0.0 0.002 0.0 3.0 0.3 0.1,3 0.019 0.01Z O,1l6 0,005 0,0/5 0.10 SSE 0.0 0.0 0.0 o.007 0.014 0.034

0. 0 Z5 0.042 0.035 0.040 0.3C1 0.021
0. C61 0.27 s

1564 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0,11 9 0.060 0.016 0.01r, 0 0.025 0.007 0,016 0.015 0.014 0.0U4 0.012 0.019 0.009

,009 0,.07 0.002 0.007 0.019 O.O47 0.19 0.10 114 0.0 0.0 0.0

0. 042 0.035 0.028 D. aD12 0.012 0.002
0. f)145 0.,005 0.016 0.19 0.0 0.0 0.0 O.009 0.054 0.0 35 0.016 0.014 0.017 0.0113.

0,005 0.22 H

0.0 0.0 0,0 0,i005 0.056 0.005 0.035 0.026 C, 007 0.005 0.26 JOl141 FREQUEJ14EY V3S1518U02014 OF MIND4 SPEED0 AND 01110313101 ATMOSPHERIC S1A1ILITY CLASS C I3130

,iz.SI 0.45 0,09 1,34 1,79 2.24 2.60 3.13 3.50 4.00 4.92 7.15

'or0L N

0.0 0.0 0.0 0.009 0.005 0.007 0.009 0.03O 0,00O2 0.002 0.0 0.009 0.05S 1011 0.0 0.0 0.0

.. 005 0.014 0,005 0.012 0.005 0.0O O.O32 0,002 0.009 0.006 0.C06 t3E 0.0 0.0 0.0 0.0 0.005 0.0 0.007 0.00o 0.0 0.009 0.OD2 0,012 0.04 E16w 0.0 0.0 0.0 0.0 0.0 0.0 0.006 0.0 0.0

}. 002 0.000 E

ESE 0.0 0.0 0.0 D.0 0.0 0.0 0.0 0.0 0.0 0.OOZ 0.00Z 0.001 0.0 O.o02 0.002 0.002 0.45 0.002 0.0 0.0 0,0 O.003 0.0 0.0 0.002 0.033 0.01 0.05 SE 0.0 0.0 0.0 0.002 3,005 0}.031 0.021 0.014 0.019 O,Ol9 0.0.52 0.Z02 SSE 0.0 0.04 3.0 0.010*

0.025 0.045 0.0 71 0.061 0,073

0. 073 O.ý 059 0.12 0.60 0.0 0.0a 0.0 0.059 0.0735 0.061 0.01.,

0.035 O.001 0,.016 3.042 0.44

.SS.1 SH 0a0 0.0 0.0 0.0 0.002 0,0 0.035 0.024 0.059 0.070 0.045 0.042 0.045 0,028 0.042 0.042 0.0*4 0.631 0.019 0.007 0.012 0.009 0.009 0.009 0.016 0,015 0.33 0.31 0.04 O.Oz 0.3 0.04Z 0.073 0.3608 0.000 0.025 0.042 0.014 0.00 7 0.055 0.44 0.0 0.0

0. 2170 0.066 0.100 0.000 0.024 0.o!4 0.00S 0.049 0.42 0.4 0.0 0.0 0.014 0.066 0.099 3.003 0.125 0.047 0.038 0.009 0.321 0,052' 0.56f 104 0.0 0.0 0.0 0.0 0.016 0.019 0.016 0.021 0.026 O. Oz5 0.016

. 0.24 0.20 WIN 0.0 0.0 0.0 0.002 0.300 0.024

0. 0 0.002 0.0 0.0 0.005 0.007
a. C4 TOTAl.

0.0 0.0 0.032 3.193 0.460 0.540 0.526 0.336 0,290 0.200 0.165 0.015 1S.74 A-1 6 Amended: June 2008 TL:

SAN ONOFRE UNIT I DSAPR APPENDIX A HISTORICAL IN FORMPJATION Table A2-7-2 JOINT FRUUENCY 0ISTRIBUTION Of W114D SPEED AND DIOECTION ArIFlERIC STABILITY CLASS 0 UlECA ( Ir/is

0.

I I

0.89

),34 1.79 2*.24 2.68 3.13 3.38

4.

02 4.47 4:.

92 7.25 TOTAL Nt 0.002 0.009 D.038 0.2.3 0.360 0.150

0. 071 0.028 0.012 0.622 0,00 7 0.010 1.11 0.0 0.0 0.035 0.160 0..43 0.362 0.355 0.zlz
0. 108
0. 049 0.031 09014 0.038 1.*6 0)E 0.0 0.0 0.014
0. 0199 80901 0.09.

0.012 0.007 0.007 0.002 0.040 0.46 ENE U.05 0.0 0.005 0.0.52 0.066 0.0600 0.007 41.00?

0.005 0. 0,2 0 0.002 0.020 0.570 0.0 0.0 0,.0 0,0 0.00Z O.011 0.060 0.Z7 0.122 0.213 0.143 0.254 0.118 O.230 0.052 0.140 0.009 0.078 0.009 0.061 0.0OS 0.076 0.068 0.241 0.64 1.38 0.0 0.0 0.012 0.017T 0.251 0.526 0Q686 0.609 0.515 0.418 0.36 0.183 0.447 4.16 SSE 0.0 0.01 U. 160 0.4041 O.*0O?

0.,711 0.-052 0.460 0.397 0.263 0.707 0.156 5.6*9 I

0.1 0.0 0.047 0.240 0.402 0.407 O.322 0.193 0, 157

0. 009 0.073 0.362 2.54 SSH 0,090 0.007*

0.197 0.324 0.219 0.181 0.061 0.060 0.040 0.251 1.67 0.042 0.230 0.190 0.220

o. 085 0.004 0.040 0.030 0.047 0.103 1.25 "514 0.0.0, 2.04 9 0.214 0.506 0.197 0.141 0.132 0.094 0.071 0.001 0,0§2
0. 2V0 1.53 FI' 0.04 O.0 0.049 0.261 0.249
0. 108 0062 0.0.7 0.322 1.00
0. l0o
0. Q01 8.174 0.421 0.35?

0.301.

0.125 0.118 0.089 0.054 0.204 OýU 5..0

0. 0 0.009 U.061 0.096 0.094 0.110 0.141
0. 007
0. 059 0.C61 0.152 0,87 0.0 0.0 0.049 0.197 0.151 0.306 0.350 0.277 0,216 0.099
0. Z2O 2.34 0,0 0.0 0.056
0. Ma 0.03 5 0.019 0.059 0.049 0.045 0.028 0.00' 0.71 11164 TOTAL 0.0 0.00?

0.0 0.124 0.080 0.9g5 0.176 2.E`5 01.270 4.438 0.195 4.31) 0.143 4.061 0.075 3.150 0.019 2.231 0.a1I 1.132 0.026 1.161 0.009 0.627 0.021 0.195 1.06 27.96 JOINT FREQUENCY O1STRIMITIGN OF KIM SPEED AND DIRECTION AfIOS'HE01C STABILI"TY CLASS E WAX (IVS) 0.45 0.09 1.34 2.68 3.13 3.58 4,02 4.47 7.15 10TAL N

0.0 0.0 0 061 0.244 0.360 o.310 0.273 0.195 0,113 0.049 0.031 0.024 0.019 1.68 0.0 0.0 0.988 OS6b 0.526 0.730 0.501 0.404 0.226 0.108 0.035 0,030 0,078 3.71 0.0 0.0 0.068 0.172 0.193 0.103 0,004 0.009 0.014 0.021 0.021 0.0 14 0.122 0.04 ENE 0.0 0.0 0.056 0 12 7 0.105 0..005 0.060 0.014 0.012

,007 0.007 0.056 0.64 E

0.0 0,0

0. 033 I0.134 0.179 0, 014 0,0)82 0,04 9 0.021 0.012 0.005 0.014 0.67 ESE

,03 0.0 0.0

0. 012 0.153 0.174 0.110 0.047 0.026 0012 0.017 0.019 0.70 SE 0.0 0.0 0.047
0. 1" L 0,31.
0. 21t 0.220 0.16 7 0.085 0.074 D.056 0.074 0.190 1.04 SSE 0.000 0.002
0. 01 6 0.122 0.072 0.0217 0.o021 0,0 26 0,00 7 0.82 S

0.00D

0. 002 0.024 0.000.

0,01 9 0.049 0.014 0.00Z 0.007

0. 007 0.007+

0.071 0.40 5511 S0300 0,031 8,035 0.0'o?

0.016 01000 0.012 0.002

0. 000 0.002 0.071

(.23 0.0D 0..0 0.0126 0,1 0.063 0.031 a.009 0.01,2 0.007 0,009 0.017 8.002 0.045 0.27 HSN1 0.0 0.0 0.015 0,052 D.071 0.037' 10 1 6O 0.012 8,007 0.0 0.01.4 0.24 N

0.0 0.0 0.014 0.018 0.054 0.000 0.061 0.000 0.0 01 0.]0 1 0.51 1084 0.0 0.0 0.015 0.054 0.007 0.01T?

0. 101 0.104
0. 021 0.026 0.016 0.014 0.19 0.000 0.581 Z. 174 S.032 2.470 1.1*5 0.496 0.543
1. l59 14.42 JO2INT FRE 6

jF0V DISTR0IBUTION4 OF HINO SPEE 0 01AND RECTION I

IWlS)

H 14E N0E NSE I

ESE o0.2z 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.4 0.0 0.0 0.0 0.0 0.0 0.0 0.0 ATPO1*PIERI0C STABILITY CLASS F SE 1.34 1.79 Z.24 1.68 3.13 3.58 4.OZ 4.47 4.42 7.13 7TOIAL 0

?O7 0.073 0.106 0.145 0.139 0.125

0.

14 1

0. 106 0.026 0.020.

0.016 D.91 0.4 Z9 0.802 1.328 1.63 2 1.126 O.301 0.009 0.190 6.30 0, 033 0.036 0.251 0.110 0.042 0.0'26 0.024 0.009 0.021 0.047 1.14 D. U.OI 0.101 0.0C68 0.028 0.03 0 0.005 0.0 0.000 0.007 0.37 01019 0.059 0.042

,.038 0.012 0.0 0.0 0.002 0.0 0.0 0.36 0.0307 0.059 0.026 0.009 2.005 0.0 0.0 0.3 0.0 0.0 0.11 0.01Z 0.089

a. 01*9 0.249 0.014 0.00 5 0.01a D.007 DI0 0.35 SSE 0.0 0.0

,0.02 O. 059 0.049 0.035 0,026 0 024 0.005 0.006 0.0 0.010 0.23 0.0 0.0 0.001 0.016 0.07 0.0 o6 0.021 0.0 0.0 0.0 0.0 0.0 0.11

$sit 0.0 0.0 3.0 0.007 0.009 0.014 0.009 0.005

1. 000 0.30S 0.0 0.0 0.0 0.06 34.0 0.0 0.0 0.020 0.075 0.002 0.0 0.005 0.000 0.007 0.0 0.0 0.0 0.07 WIN 0.0 0.0 0.002 0.04 0.0 -,

0.0 0.0 0.02 0.0 0.002 2.04 0U 0.0 0.054 0.033 0.002 0.01 0.005 0.2

0. 002 0.002 0.0
0. Is 10,)N 0.0 0.0 0.009 0.019
0. C47 0.042 0.050.

O,O"D 0.516 0:,01 0.002 0,002 O. 25 tol 0.0 0.002 0.019 0.012 0.026 0.026 0.019 0.016 0.019 0,014 0,031.

0.035 0.16

[NW*4 TOTAL 0.0 0.0 0.0 0.0 0.0O7 0.212 0.021 1.062 0.025 1.770 0.028 2..74 0.072 E.209 0.031 1.49Z 0.016 0.-558 0.074 0.517 0.009 O.Z9 0.0 0.105 0.00G 0.190 D.19 10.53 JOINT FREQUENCY DISTRI1BUTION OF 1I40P 50PE AND OIRECTlION i

Anfl0SPHERIC STABILITY CL45I Vi A-17 Amended: June 2008 TL:

SAN ONOFRE UNIT 1 DSAR APPENDIX A HISTORICAL INFORMATION Table A2-7-3 UMAX ("/S 1 0.22 0.45 0.89 1.34 1.79 2.24 2.68 3.13 3.58 4.02 4.47 4.92 7.15 TOTAL N

NNE HE ENE E

0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.002 0.0 0.0 0.002 0.007 0.009 0.009 0.005 0.009 0.052 0.031 0.04Z 0.019 0.019 0.148 0.122 0.038 0.035 0.040 0.308 0.099 0.012 0.009 0.061 0.769 0.110 0.031 0.007 0.113 1.596 0.073 0.002 0.0 0.160 1.972 0.040 0.002 0.0 0.127 2.122 0.038 0.002 0.0 0.134 1.932 0.03S 0.0 0.0 0.042 1.356 0.002 0.0 0.002 0.085 1.406 0.019 0.002 0.0 0.79 11.67 0.58 0.14 0.08 ESE SE 0.0 0.0 0.0 0.005 0.014 0.0 0.040 0.026 0.016 0.012 0.007 0.021 0.007 0.019 0.007 0.092 0.0 0.087 0.0 0.073 0.0 0.024 0.0 0.005 0.0 0.009 0.09 0.37 SSE 0.0 0.0 0.012 0.028 0.028 0.014 0.009 0.005 0.019 0.014 0.024 0.005 0.009 S

SSH 0.0 0.0 0.0 0.0 0.002 0.002 0.024 0.009 0.014 0.012 0.005 0.005 0.0 0.005 0.012 0.005 0.0 0.024 0.024 0.014 0.0 0.033 0.009 0.028 0.005 0.0 SH HSH H

IM4 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.002 0.002 0.007 0.009 0.007 0.012 0.007 0.007 0.012 0.002 0.038 0.016 0.002 0.021 0.031 0.026 0.0 0.0 0.016 0.035 0.002 0.0 0.009 0.026 0.0 0.0 0.012 0.019 0.0 0.0 0.0 0.019 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.03 0.04 0.12 0.16 NH 0.0 0.0 0.0 0.005 0.012 0.012 0.026 0.019 0.019 0.002 0.016 0.0 0.002 0.11 NNH 0.0 0.0 0.0 0.005 0.0 0.016 0.012 0.026 0.026 0.012 0.0 0.0 0.0 0.10 TOTAL 0.0 0.007 0.085 0.322 0.524 0.628 1.107 1.986 2.379 2.447 2.198 1.450 1.537 14.67 0.17 0.09 0.14 TOTAL HOURS CONSIDERED ARE 42546 MIND MEASURED AT 10.0 METERS.

OVERALL HIND DIRECTION FREQUENCY HIND DIRECTION' N

MHE FREQUENCY:

4.6 23.7 NE ENE 3.1 1.5 E

ESE SE SSE S

SSH SH 1.7 2.4 6.9 7.0 6.1 5.6 5.8 HSH H

NSA NH NNH TOTAL 7.5 11.1 7.3 3.7 2.0 100.0 OVERALL HIND SPEED FREQUENCY MAX MIND SPEED EM/S)3 0.224 0.447 0.094 1.341 1.788 2.235 2.682 3.129 AVE HIND SPEED IH/S)I 0.112 0.335 0.671 1.118 1.565 2.012 2.459 2.906 HIND SPEED FREQUENCY' 0.00 0.03 1.40 6.53 11.58 13.20 14.24 14.04 THE COVERSION FACTOR APPLIED TO THE HIND SPEED CLASSESS IS 0.447 3.576 4.023 4.470 4.917 7.153 3.3S3 3.800 4.247 4.694 6.03S 11.42 8.86 6.44 3.93 8.31 DISTANCES DIRECTION DISTANCE ELEVATION DISTANCES DIRECTION DISTANCE FACTOR AND TERRAIN S

SS5

0.

0.

-6.

-6.

HEIGHTS IN HETERS S"

HSN H

0.
0.

74.

-6.

-6.

24.

AS FUNCTIONS OF DIRECTION FROM THE SITE:

HNN NH NNW N

NNE HE ENE

69.
69.
76.

154.

129.

129.

153.

24.
24.
24.
24.
24.
24.

24.

E ESE SE 211.

332.

547.

24.
24.

24.

SSE 0.

-6.

AND SITE-SPECIFIC CORRECTION FACTORS AS FUNCTIONS OF DIRECTION FROM THE SITE;

=

S SSH SH HSH H

MIH NH NNH N

NNE NE ENE E

593.

481.

398.

34S.

320.

317.

319.

342.

391.

472.

581. 703.

885.

1.00 1.52 1.11 1.33 1.63 1.39 1.27 1.00 1.03 1.23 1.27 1.04 1.23 ESE SE SSE 1023.

954.

765.

1.05 1.19 1.51 A-18 Amended: June 2008 TL:

SAN ONOFRE UNIT 1 DSAR APPENDIX A HISTORICAL INFORMATION Table A2-7-4 SAN RE UI 791IET;T. RSE; -SPEC TERECI UNIT 11 SITE SPEC.

OPEN TERR.

RECIRC.; CONT.

RELEASE CORRECTED USING SITE-SPECIFIC FACTORS SPECIFIC POINTS OF INTEREST RELEASE TYPE OF DIRECTION ID LOCATION FRO" SITE DISTANCE IHILES)

(METERS) s S

S S

S S

S S

S S

S S

S S

SS EAR SECTORS EAR SECTORS EAB SECTORS EAB SECTORS EAR SECTORS EAR SECTORS EAB SECTORS EAB SECTORS N-0 N-B H-B H-B N-B N-B C-J C-J C-J C-J C-J C-J C-J K-H K-H K-H NH N

NNE HE ENIE E

ESE SE SSE S

SSW SN HSM 0.20 0.20 0.20 0.21 0.24 0.29 0.36 0.44 0.55 0.64 0.59 0.48 0.37 0.30 0.25 0.21 320.

317.

319.

342.

391.

472.

581.

703.

885.

1023.

954.

765.

593.

481.

398.

345.

X/Q ISEC/CUB.HETER)

NO DECAY UNDEPLETED 6.BE-06 6.6E-06 1.3E-OS 8.2E-06 5.1E-06 3.4E-06 2.3E-06 1.SE-06 1.6E-06 1.2E-06 1.3E-06 1.6E-06 4.1E-06 4.6E-O5 7.7E-06 5.7E-06 X/Q (SEC/CU8.METER) 2.260 DAY DECAY UNOEPLETED 6.8E-06 6.6E-06 1.3E-05 0.2E-06 5.1E-06 3.4E-06 2.3E-06 1.5E-06 1.6E-06 1.2E-06 1.3E-06 1.6E-06 4.1E-06 4.6E-O0 7.7E-06 5.6E-06 X/Q I SEC/CUB.tiETER) 8.000 DAY DECAY DEPLETED 6.SE-06 6.3E-06 1.3E-05 7.0E-06 4.8E-06 3.2E-06 2.ZE-06 1.4E-06 1.5E-06 1.1E-06 1.2E-06 1.SE-06 3.8E-06 4.4E-05 7.3E-06 5.4E-06 D/Q (PER SQ.IIETER1 2.ZE-08

2. 7t-08 7.ZE-08
5. ZE-OB 3.8E-08 3.1E-08 2.4E-00 1.9E-08 2.3E-08 1.OE-08 6.SE-09 6.4E-09 1.SE-08 1.6E-07 Z.OE-08 1.4E-08 EAB EAR EAR EAR EAB EAR EAS EAB SECTORS SECTORS SECTORS SECTORS SECTORS SECTORS SECTORS SECTORS VENT AND BUILDING PARAHETERS:

RELEASE HEIGHT (METERS)

DIAMETER (METERS)

EXIT VELOCITY (METERS)

ALL GROUND LEVEL RELEASES.

36.60 0.0 0.0 REP.

HIND (EIGHT BUILDING H(EIGHT BLDG.HIN.CRS.SEC.AREA HEAT EMISSION RATE (HETERS) 1HETERS)

ISQ.METERS)

ICAL/SECI 10.0 41.0 1440.0 0.0 A-19 Amended: June 2008 TL:

SAN ONOFRE UNIT 1 DSAR APPENDIX A HISTORICAL INFORMAT ION TABLE A5-1 DIRECT GAMMA SOURCES AND ISOTOPIC INVENTORY FOR THE SPENT FUEL GAP ACTIVITY 90 HOURS FOLLOWING SHUTDOWN Energy Group Noble Gas Activity (Gammais)

(14 Fuel Rods)*

4.26 x 10" I.

E <= 0.4 MeV II 0.4 M4eV < E <= 0.8 MeV I111 0.8 MeV < E <= 1.7 MeV IV E > 1.7 MeV 8.0 x 10' Negligible Negligible I s ct ope Kr-85 Kr-85m Kr-87 Kr-88 Xe-i1S3m Xe-13 3 invent orv, Ci/MWt 1.2 x il-4 0-E 1 0 i

10-10 10.4 1.5 10,

5. a 0.

Xe-135 One side of the 14 x 14 array fuel assembly (14 fuel rods) is assumed to be involved in the spent fuel handling accident and ruptured so as to release radioactive nuclides into the spent fuel pool.

A-20D Amended: June 2008 TL:

SAN ONOFRE UNIT 1 DSAR APPENDIX A HISTORICAL INFORMATION TABLE A5-2 MAXIMUM FISSION AND CORROSION PRODUCT ISOTOPIC INVENTORIES OF REACTOR COOLANT FOR REFE"ENCE ONE PERCENT CLADDING DEFECT CASE (BASED UPON 5700F COOLANT)

Sheet 1 of 2 Specific Activity

.LCi/cc Isotope Br-84 Kr-S5 Kr-85 (2)

Kr-87 Kr-88 0.16 4.2 1.3 0.73 2.1 Rb-S88 Rb-89 sr-89 sr-90 Y-90 sr-91 Y-91 No-99 To-129 1-129 1-131 Te-132 1-132 1-133 Xe-133 Te-134 1-134 Cs-134 1-135 Xe-135 Cs-136 Cs-137 xe-138 Cs-138 Ba-140 La-140 Co-6 0 Fe-59 2.1

5. OXlO 2 2.0x10-3 1.9x10" 1
1. OXzlO 3 2.SX10-2 2.5 1.6x10-2 2.4x10-8 Coolant Inventory, Ci 31 800 250 140 400 400 10 0.4 0.02 0.04 0.2 5.3 477 3

0.5x10-S 267 25 95 363 30.200 2.7 50 130 189 840 13 3000 61 100 0.4 0.1 0.29 0.36 1.4 0.13 0.50 1.9 158

1. 4x10-2 0.26 0.68 0.99 4.4 7.0x10-2 15.7 0.32 0.52
2. 1x10-3
7. 1x10-4 1.5x10-3 1.9x10-3 A-21 Amended: June 2008 TL:

SAN ONOFRE UNIT 1 DSAR APPENDIX A HISTORICAL INFORMATION TABLE A5-2 sheet 2 of.2 coolant specific Activity inventory,

Isotope, uCilce Ci CO-SB 8.5x10-3 1.6 sn 2.3x10-2 4.4 Kn-54 4.4x10"3 0.84 A-22 Amended: June 2008 TL:

SAN ONOFRE UNIT 1 DSAR APPENDIX A HISTORICAL INFORMATION TABLE A5-3 HAXIMUM FISSION AND CORROSION PRODUCT GAMMA SOURCES OF REACTOR COOLANT lit CLADDING DEFECTS)

Time After Shutdown 0

JJL.__

_.L1 2

h_

h

.IJday Iwk

_I ML _

source and Energy Group, HqV Radiation sources Released. NaV/e 0.4 I.OxlO14 I.oxlO1 4

9.9x10 1 3 9.4x10 1 3 8.0x0O13 3.6x10 1 3 1.9x1012 0.e 9.2x1013 6.0x013 7.8x1013 7.6x1013 7.4x1013 6.9X1013 6.9xI013 1.7 1.5x10 1 3 9.7x1012 6.5x,012 5.2x1012 2.9x1011 2.9x101o 1.9xI010 2.5 4.8xl013 3.1x10 1 3 2.3x1013 2.9x1012 9.0x1011 Inotone Iodine Activities. cl 1-131 267.0 267.0 267.0 260.0 244.0 147.0 20.0 1-132 88.0 66.0 50.0 8.6 0.086 nag nag 1-133 363.0 351.0 340.0 279.0 163.0 13.8 nag 1-134 50.2 22.5 9.6 0.096 nag nag nag 1-135 189.0 172.0 154.0 92.3 15.7 nag nag A-23 Amended: June 2008 TL:

SAN ONOFRE UNIT I DSAR APPENDIX A HISTORICAL IlN FOR 1-T ION UNIT 1 RADIOACTIVE RELEASES Table A5-4 1968-1996 AIRBORNE IODINE PARTICULATE 1968 1969 1970 1971 1972 1973 1974 1975 1976 1977 1978 1979 1980 1981 1982 1983 1984 1985 1986 1987 1988 1989 1990 1991 1992 1993 1994 1995 1996 FISSION/

ACTIVATION GASES 4.83E+00 2.56E+02 1.61 E+03 5.99E+03 1.91 E+04 1.07E+04 1.78E+03 1.79E+03 4.17E+02 1.67E+02 2.20E+03 7.99E+02 1.05E+03 4.22E+02 8.61 E+01 1.06E+01 8.62E+01 3.83E+03 4.11E+02 9.81E+02 2199E+03 1.12E+03 1.80E+03 2.49E+03 4.12E+03 4.20E+02

<LLD

<LLD

<LLD 6.51 E-01 2.31 E-04 2.46E-01 4.48E-03 1.81 E-04 2.76E-04 2.44E-04 2.53E-04 8.68E-03

<LLD 2.92E-06 6.78E-06 1.14E-03 1.99E-04 4.1OE-04 1.03E-02 2.09E-03 7.22E-03 1.51E-03 1.57E-02 2.94E-04

<LLD

<LLD

<LLD 1.18E+00 8.74E-05 3.58E-02 1.11E+00 4.83E-06 2.49E-03 3.68E-05 8.41 E-01 3.12E-02 4.66E-07 2.52E-06 2.71 E-06 2.49E-05 9.34E-06 7.11 E-06 5.07E-04 1.37E-04 2.76E-05 9.90E-04 1.12E-05 6.86E-06

<LLD

<LLD

<LLD TRITIUM 2.48E+00 1,08E+01 5.36E+01 2.81 E+02 2.69E+02 9.14E+01 3.43E+01 4.72E+01 7.57E+01 5.75E+01 4.27E+01 3.69E+01 1.40E+01 5.63E+01 3.93E+00

<LLD 2.89E+01 1.70E+00 1.51E+01 2.05E+01 3.37E+01 9.13E+01 1.68E+01 5.19E+01 1.19E+01 3.47E+00 3.18E+00 3.75E+00 FISSION/

ACTIVATION PRODUCTS 1.64E+00 8.OOE+00 3.76E+00 9.51 E-01 3.03E+01 1.60E+01 5.03E+00 1.22E+00 7.39E+00 5.1OE+00 1.22E+01 1.20E+01 1.12E+01 4.16E+00 2.15E+00 1.22E+00 2.74E+00 7.79E+00 8.51 E-01 8.42E-01 7.11 E-01 6.66E-01 4.OOE-01 4,20E-01 3.42E-01 1.14 E+00 2.32E-03 6.99E-02 4.53E-02 LIQUIDS DISSOLVED &

ENTRAINED GASES 5.36E+01 3.37E+00 4.74E+00 1.25E+01 4.53E+00 1.82E+00 2.73E+01 2.90E+00 4.94E-01

<LLD

<LLD 2.30E-01 3.12E+01 9.80E-01 1.89E+00 1.46E+01 8.03E+00 5.47E+00 3.04E+00 3.12E+00 7.75E-02

<LLD

<LLD

<LLD TRITIUM 3.53E+03 4.77E+03 4.57E+03 3.48E+03 4.07E+03 3.85E+03 4.OOE+03 3.39E+03 1.79E+03 4.21 E+03 3.35E+03 1,03E+03 2.97E+02 5.45E+02 1.57E+01 3.39E+01 2.38E+03 4.53E+02 2.27E+03 1.53E+03 9.62E+02 1.42E+03 1.25E+03 3.05E+03 4.45E+02 1.53E-02 8.64E+00 3.08E+00 A-24 Amended: June 2008 TL:

SAN ONOFRE UNIT 1 DSAR APPENDIX A HISTORICAL INFORMATION TABLE A5-5 AVERAGE REACTOR COOLANT ACT=VITY WITH 0.1 PERCENT DZECTIVE FUEL CLADDING Isotope aci/=) L sote Itotpe B-3 3.40 x 100 Cs-137 2.16 x 100 Kr-85 3.36 x 10-1 1-131 1.92 x 10-1 Kr-85Z 1.28 x 10-1 1-132 6.80 x 10-2 Kr-87 1.00 x 10-1 1-133 2.60 x 10-1 Kr-88 2.88 x 10-1 1-134 3.60 x 10-2 Xe-133 2.16 x 10-1 1-135 1.36 x 10-1 Xe-135 6.02 x 10-1 Mn-54 6.0 x 10-3 Xe-138 4.40 x 10-2 Xn-56 3.2 x 10-2 MO-99 3.24 x 10-1 Co-58 1.2 x 10-2 Cs-134 9.40 x 10-2 Pe-59 2.6 x 10-3 Co-60 2.1 x 10-3 A-25 Amended: June 2008 TL:

SAN ONOFRE UNIT 1 DSAR APPENDIX A HISTORICAL INFORMATION TABLE A5-6 ESTIMATED ANNUAL RADIOACTIVE WASTE QUANTITIES PROCESSED DURING NORMAL OPERATION sheet 1 of 2 Source Ouantity.

gal Assumptions and comments LIQUID WASTES Input of coolant radwaste Boron dilution for fuel depletion One refueling shutdown and startup Four hot shutdowns and startups Two cold shutdowns and startups Inputs to decontamination drain tank Miscellaneous reactor coolant leakage Floor drains Resin sluice water Decontamination showers 200,000 59,700 164,000 106,000 9,050 50,000 935 9,000 One each at 100, 200, and 300 cycle days plus one at 100 ppm boron one at 50 hrs core life and 300 cycle days 20 gal/day into auxiliary buidling.

40 lb/day leakage to containment atsmosphere 2 ft 3 water/ft 3 resin for total of 125 ft 3

5 showers/day at 30 gal/shower for 30 days/year A-26 Amended: June 2008 TL:

SAN ONOFRE UNIT 1 DSAR APPENDIX A HISTORICAL INFORMATION TABLE A5-6 Sheet 2of 2 Source LIQUID WASTES Inputs to radioactive chemical lab drain tank Sampling and lab drains Floor drains Steam generator blowdown (non-routine operation)

Quantity, gal Assumptions and Comments 3,900 30,000 5 samples/week at 15 gal/sample, including purge Nonroutine operation with steam generator tube leak.

30 gal/min blowdown for 322 days/year 13,900,000 A-27 Amended: June 2008 TL:

SONGS 2/3 June 2008 Defueled Safety Analysis Report (Unit 1) Report Amendment Contents Page 1 of 3 PDF Report Contents PDF Report Contents Doc Type Document Number Sheet Rev Pages Title NRC Amendment Contents 0 Files Merged 0

Total Pages Section 1 Section 1 Figures 1 Figure 1-1 Figure 1-2 3 Files Merged Doc Type Document Number Sheet Rev 06R DSAR-1.0 10 Pages Title 6

Introduction Chapter 1 Figures 1

General Site Area 1

Plot Plan After ISFSI Phase I Completion 06R DSAR-01.00-01 06R DSAR-01.00-02 3

4 8

Total Pages Section 2 Section 2 Figures 2 Figure 2-1 Figure 2-2 Figure 2-3 Figure 2-4 5 Files Merged Section 3 Section 3 Figures 3.1 Figure 3.1-1 Figure 3.1-2 Figure 3.1-3 Figure 3.1-4 Figure 3.1-5 Figure 3.1-6 Figures 3.2 Figure 3.2-1 Figure 3.2-2 Figure 3.2-3 Figure 3.2-4 Figure 3.2-5 Figure 3.2-6 Figure 3.2-7 Figure 3.2-8 Figure 3.2-9 Doc Type Document Number Sheet Rev 06R DSAR-2.0 9

06R 06R 06R 06R DSAR-02.00-01 DSAR-02.00-02 DSAR-02.00-03 DSAR-02.00-04 3

3 3

3 Pages Title 6

Characteristics Chapter 2 Figures 1

Site Plan (Operating Plant) 1 Exclusion Area Boundary 1

Beach Passageway and Seawall Section 1

Low Population Zone 10 Total Pages Doc Type Document Number Sheet 06R DSAR-3.0 06R DSAR-03.01-01 06R DSAR-03.01-02 06R DSAR-03.01-03 06R DSAR-03.01-04 06R DSAR-03.01-05 06R DSAR-03.01-06 Rev Pages Title 19 22 Facility Description Section 3.1 Figures 4

1 (Deleted) 7 1

(Deleted) 7 5

5 6

06R 06R 06R 06R 06R 06R 06R 06R 06R DSAR-03.02-01 DSAR-03.02-02 DSAR-03.02-03 DSAR-03.02-04 DSAR-03.02-05 DSAR-03.02-06 DSAR-03.02-07 DSAR-03.02-08 DSAR-03.02-09 4

4 4

4 4

4 4

4 4

1 (Deleted)

(Deleted)

(Deleted)

(Deleted)

Section 3.2 Figures (Deleted)

(Deleted)

(Deleted)

(Deleted)

(Deleted)

(Deleted)

(Deleted)

(Deleted)

(Deleted)

Amended: June 2008 TL:

SONGS 2/3 June 2008 Defueled Safety Analysis Report (Unit 1) Report Amendment Contents Page 2 of 3 Section 3 Figure 3.2-10 Figure 3.2-11 Figure 3.2-12 Figure 3.2-13 Figure 3.2-14 Figure 3.2-15 Figure 3.2-16 Figure 3.2-17 Figure 3.2-18 Figure 3.2-19 Figure 3.2-20 Figures 3.3 Figure 3.3-1 Figure 3.3-2 Figure 3.3-3 Figure 3.3-4 Figures 3.6 Figure 3.6-1 Figures 3.7 Controlled Figure 3.7-1 (2/2)

Figures 3.9 Controlled Figure 3.9-1 (/N/A)

Controlled Figure 3.9-2 (/N/A)

Controlled Figure 3.9-3 (/N/A)

Figure 3.9-4 33 Files Merged Doc Type 06R 06R 06R 06R 06R 06R 06R 06R 06R 06R 06R 06R 06R 06R 06R Document Number DSAR-03.02-1 0 DSAR-03.02-11 DSAR-03.02-12 DSAR-03.02-13 DSAR-03.02-14 DSAR-03.02-15 DSAR-03.02-16 DSAR-03.02-17 DSAR-03.02-18 DSAR-03.02-19 DSAR-03.02-20 DSAR-03.03-01 DSAR-03.03-02 DSAR-03.03-03 DSAR-03.03-04 Sheet Rev Pages Title 4

1 (Deleted) 4 1

(Deleted) 4 1

(Deleted) 4 1

(Deleted) 4 1

(Deleted) 4 1

(Deleted) 4 1

(Deleted) 4 1

(Deleted) 4 1

(Deleted) 4 1

(Deleted) 4 1

(Deleted)

Section 3.3 Figures 4

1 (Deleted) 4 1

(Deleted) 4 1

(Deleted) 4 1

(Deleted)

Section 3.6 Figures 4

1 (Deleted)

Section 3.7 Figures 0

(Deleted)

Section 3.9 Figures 0

(Deleted) 0 (Deleted) 0 (Deleted) 4 1

(Deleted) 54 Total Pages 06R DSAR-03.06-01 02X U1-E-0001 06R DSAR-03.09-04 Section 4 Section 4 Figures 4 Figure 4-1 Figure 4-2 Figure 4-3 Figure 4-4 5 Files Merged Doc Type Document Number Sheet 06R DSAR-4.0 Rev 14 06R 06R 06R 06R DSAR-04.00-01 DSAR-04.00-02 DSAR-04.00-03 DSAR-04.00-04 7

7 7

4 Pages Title 13 Licensee Organization Chapter 4 Figures 1

Companies and Corporate Center 1

Business Units 2

Nuclear Organization 1

Independent Review Organization 18 Total Pages Amended: June 2008 TL:

SONGS 2/3 June 2008 Defueled Safety Analysis Report (Unit 1) Report Amendment Contents Page 3 of 3 Section 5 Section 5 1 Files Merged Doc Type Document Number 06R DSAR-5.0 Sheet Rev Pages Title 13 9

Radioactive Waste Management 9

Total Pages Section 6 Section 6 Doc Type Document Number 06R DSAR-6.0 Sheet Rev Pages 9

17 Title Radiation Protection 1 Files Merged 17 Total Pages Section 7 Doc Type Document Number Sheet Rev Pages Title Section 7 06R DSAR-7.0 6

1 (Deleted) 1 Files Merged I

Total Pages Section 8 Section 8 Doc Type Document Number 06R DSAR-8.0 Sheet Rev 12 Pages 5

Title Accident Analysis I Files Merged 5

Total Pages PDF Report Appendix A PDF Report Appendix A 1 Files Merged Doc Type Document Number 06R DSAR-APPENDIX A Sheet Rev 6

Pages Title 28 Appendix A 28 Total Pages Appendix B Appendix B 1 Files Merged Doc Type Document Number 06R DSAR-APPENDIX B Sheet Rev 8

Pages Title 1

Appendix B - Fire Protection I

Total Pages 11 NRC Files Created 151 Total Pages Amended: June 2008 TL: