ML082330419
ML082330419 | |
Person / Time | |
---|---|
Site: | Vermont Yankee |
Issue date: | 08/12/2008 |
From: | NRC/SECY/RAS |
To: | |
SECY RAS | |
References | |
50-271-LA, RAS M-256 | |
Download: ML082330419 (10) | |
Text
>
2rl- 0
-mm New England Coalition >* > -'n CD C,
Co0
- KmC OEM- I
(Vermont Yankee Nuclear Power Station). Docket No. 50-271-LA July 2008 Evidentiary Hearing Exhibit List Party Exh.#
Witness/
Panel Description Offered in Evid. Adm.
(datelpage)Ad.R.Wrn JRe.
Action Wdrn.
NEC- Joram Curriculum Vitae of Joram Hopenfeld. 7/21/08 V, JH_02 Hopenfeld Tr. at 779 NEC- Joram Joram Hopenfeld, "Review of Entergy Nuclear Vermont Yankee, LLC and 7/21/08 V/
JH_03 Hopenfeld Entergy Nuclear Operations, Inc. ("Entergy") Analyses of the Effects of Tr. at 779 Reactor Water Environment on Fatigue Life of Risk-Significant Components during the Period of Extended Operation" (April 21, 2008).
NEC- JorinD SAME AS ENTERGY EXEhIBiT E2-10: Structural Integrity Associates JH 04 o, "VY-1 6Q-<301: Feedwater NozzeeStress fHistory Developm
~~ Green Functions" (July 12, 2007).~
NEC Jija SAME AS ENTERGY EX11113if E2-1 1: SIA, "VY-l 6Q-302: Fatiguec JH 0lpifl, A ayssof Fe~dw.ater Nozzle" (July~18, 2007).C_ _ _ _ _ _ _ _ _
NC rai SIA, "VY-l 6Q`-303: Environmental Fatigue Evaluation of Reactor 7/21/08 V/
JH_06 Hopenfeld Recirculation Inlet Nozzle and Vessel Shell/Bottom Head" (July 5, 2007). Tr. at 779 NEC- Joraiii7 ~SANIEAS ENTERGY EXHIBIT E2-13:SIA, V-6Q34Reiclto
~iJII07~ enfe~d Oute Nozzle Finite ElementModel (Jl 12, 2007).irclaio NEC- JOrain\ AEA~NEGP~1IE-4 SAMEAS_________EXHE3_TE2_14:__IA "VY-1 6Q-305: Recirculation JH_08 Ilopilefeld3 Outlet Stress History Developmienit for Nozzle Green Func~tion" (July 1, 12007). 7 4_-Pý -,%2 ý, , "ý,,-
Joram SIA, "VY-16Q-401: Environmental Fatigue Analysis for the Vermont Hopenfeld Yankee Reactor Pressure Vessel Feedwater Nozzles" (July 26, 2007).
Jorarni SAME AS~ENTERGYEXH ITPE2-22: SIA,-VY 16Q-4(02 En'ivir-onmientaI Hlopenfeld Fatigue Anlsi~~ h emOtYne citrPressufre VcebdRaeator RecrlultionOttlet Nozzle" (July,6. -0)
Joram SIA, "VY- 16Q-403: Environmental Fatigue Analysis for the Vermont Yankee Hopenfeld Reactor Pressure Vessel Core Spray Nozzle" (July 26, 2007).
NEC-? Joram' ASfeNTrnRuGY E"SmI NIS arITo2f2MenHd 820:ASMIE Cod/e JaVYa-I9)00:
H20 Hopeinfeld betiwee theU.S.NFatule Evagulation ofmReactor Secd tf aNozzle"(January 30,.t7 NEC ior 4r
%ior, ENTLERGY EXHITu E2-27:.;SLA, 'Y1Q33 SAFS eda
~JH,21' Hlopcnftc1 Ncizfe.Enviro~i~enta1 ~Fatigue Evaluation"Difay30, (~ 2008).
NEC- Joram NRC Staff Memorandum: "Summary of Meeting Held on January 8, 2008 7/21/08 iii_22. Hopen feld between the U. S. Nuclear Regulatory Commission Staff and Entergy Nuclear Tr. at 779 Operation, Inc. Representatives to Discuss the Response to a Request for Additional Information Pertaining to the Vermont Yankee Nuclear Power Station License Renewal Application.."
NEC- Joram NRC, "NRC Regulatory Issue Summary 2008-10 Fatigue Analysis of Nuclear 7/21/08 V/
JH_23 Hopenfeld Power Plan Components" (April 11, 2008). .Tr. at 779 NEC- Joram NRC, "Notification of Information in the Matter of Oyster Creek Nuclear 7/21/08 V JH_24 Hopenfeld Generating Station License Renewal Application" (April*3, 2008). Tr. at 779 NEC- Joram Drawing 5920-624: Reactor 81N DIA Nozzle MK N5A & B. 7/21/08 V JH_25 Hopenfeld Tr. at 779 K.-NEC- Jo~'r~ni ~SAtiEAS ENTERGY EXHIBIT E.2-10:.Argonne4Nattionil Laboratory,~
Vattria.k,,ANL.0.1.8,.....................ary,,:0.7,.
P11526 ol' f"'R. ('1ýant Environmecnts onithe FatigiucLfILof#JRizctor
~I~
NEC- Joram NRC, Transcript of Advisory Committee on Reactor Safeguards ("ACRS") 7/21/08 V" JH_27 Hopenfeld Subcommittee on Materials, Metallurgy and Reactor Fuels (December 6, Tr at 779 2006) (Excerpt). ,, ,,-,
Nt C- JToram _ TE-RGY EXHIBITf E2- L SOlI~lrtici
________ g~(Feburary 7, 2008)(Excerpt).§.,
NEC- Joram E.R.G. Eckert and R. Drake, Heat and Mass Transfer 212 (2 nd ed. 1959). 7/21/08 V" JH-_29 Hopenfeld Tr. at 779 ___
NEC- Joram H. Schlichting, Boundary Layer Theory 555 (J. Kestin trans., 4h ed. 1960). 7/21/08 V/
JH_30 Hopenfeld Tr. at 779 NEC- Joram J.P. Holman, Heat Transfer226, 413 (5h ed. 1981). 7/21/08 V/
JH_31 Hopenfeld Tr. at 779 NEC- Joram Vermont Yankee Nuclear Power Corporation, "Vermont Yankee 2001 7/21/08 V JH_32 Hopenfeld Summary Reports for In-Service Inspection and Repairs or Replacements" Tr.. at 779 (August 20, 2001).
NE- J~oramii NEC~a1~SAME AS ENTERiY EXH1IBT[- E2098: Eneryý, "Licenise Renewal J 4 NEC ,+_ =-_*J~am NRC, "Safety Evaluation by-the Office of Nuclear Reactor Regulation Related 7/21/08* V" JHI35 Hopefel to Amendment No. 229 to Facility Operating License No. DPR-28: Entergy Tr. at 779 Nuclear Vermont Yankee, LLC and Entergy Nuclear Operations, Inc.
Vermont Yankee Nuclear Power Station, Docket No. 50-271F' (Excerpt).
NEC- Joram JoaR Hopenfeld, Review of Li cense Renewal Application for Vermont 7/23/08 V/
JH36 Hopenfeld Yankee Nuclear Power Station: Program for Management of Flow- Tr. at 1432 Accelerated Corrosion (April 24, 2008). [PROPRIETARY AND NON-PROPRIETARY VERSIONS SUBMITTED]
NEC- Joram EPRI, "Tackling the Single-Phase Erosion Corrosion Issue" (April 18, 1988). 7/23/08 V/
JH_37 Hopenfeld
- Tr. at 1432 NEC- Joram EPRI, "Recommendations for an Effective Flow-Accelerated Corrosion 7/23/08 V JH_38-P Hopenfeld Program (NSAC-202L-R3)" (May 2006). [PROPRIETARY] Tr. at 1432 NEC- Joram NRC, Transcript of ACRS Thermal Hydraulic Phenomena Subcommittee 7/23/08 v/
JH_39 Hopenfeld (January 26, 2005) (Excerpt). Tr. at 1432 NEC- Joram Y. M. Femg et al., "A New Approach for Investigation of Erosion-Corrosion 7/23/08 V JH-_40 IHopenfeld Using Local Flow Models," 55 CorrosionNo. 4, 332-42 (April 1999). Tr. at 1432
NEC- Joram Portland General Electric Co., "Secondary Piping Erosion/Corrosion" (July 7/23/08 "
JH_41 Hopenfeld 31, 1987). Tr. at 1432 NEC - Jorarn "V NEC- Jorane "VY Piping FAC Inspection Program PP7028.- 2007 Refueling Outage: 7/23/08 "
Tr. at 1432 JH-42 Hopenfeld Inspection Location Worksheets/Methods and Reasons for Component Selection" (May 11, 2006).
NEC- Joram "PP7028 FAC Inspections 2004 Refueling Outage." 7/23/08 V" JH_43 Hopenfeld Tr. at 1432 NEC- Joram Entergy, "Focused Self-Assessment Report: Vermont Yankee Piping Flow 7/23/08 "
JH_44 Hopenfeld Accelerated Corrosion Inspection Program" (October 28, 2004). Tr. at 1432 NEC- J 'oraen NRC, "NRC Information Notice 2001-09: Main Feedwater System 7/23/08 V" 1 Degradation in Safety-Related ASME Code Class 2 Piping Inside the Tr. at 1432 Containment of a Pressurized Water Reactor" (June 12, 2001).
am G 8iTAFdtEDIRBTi2o:nPIRC14a- nfrm~ ~ation Nt2A91 earn11 Ocneiapr Fceewaecr DIist~ buio P ~g, 12,_9__1) _________ ___l NEC- Joram NRC, "NRC Information Notice 91-18: High-Energy Piping Failures Caused 7/23/08 ,
JH47 Hopenfeld by Wall Thinning" (March 12, 1991). Tr. at 1432 NEC- Joram NRC, "NRC Information Notice 92-35: Higher than Predicted 7/23/08 V/
JH_48 Hopenfeld Erosion/Corrosion in Unisolable Reactor Coolant Pressure Boundary Piping Tr. at 1432 Inside Containment at a Boiling Water Reactor" (May 6, 1992).
NEC- Joram NRC, "NRC Information Notice 93-06: Potential Bypass Leakage Paths 7/23/08 JH_49 Hopenfeld Around Filters Installed in Ventilation Systems" (January 22, 1993). Tr. at 1432 NEC- Joram NRC, "NRC Information Notice 95-1 1: Failure of Condensate Piping Because 7/23/08 V/.
JH_50 Hopenfeld of Erosion/Corrosion at a Flow-Straightening Device" (February 24, 1995). Tr. at 1432 NEC- Joram NRC, "NRC Information Notice 97-84: Rupture in Extraction Steam Piping as 7/23/08 1/
JH_51 Hopenfeld a Result of Flow-Accelerated Corrosion" (December 11, 1997). Tr. at 1432
NEC- Joram NRC, "Kewaunee 3Q/2006 Plant Inspection Findings" (December 21, 2006). 7/23/08 V" JH_52 Hopenfeld Tr. at 1432 NEC- Joram Nuclear and Industrial Safety Agency, "Interim Summary on Secondary 7/23/08 V JH_53 Hopenfeld Piping Rupture Accident at Mihama Power Station, Unit 3 of the Kansai Tr. at 1432 Electric Power Co., Inc." (September 27, 2004).
NEC- Joram Joram Hopenfeld, "Assessment of Proposed Program to Manage Aging of the 7/23/08 V" JH_54 Hopenfeld Vermont Yankee Steam Dryer Due to Flow-Induced Vibrations" (April 25, Tr. at 1189 2008).
NEC- j()'111 'SAMN1Eý'A S ENTERGY EXHIBIr E3 06;~ GE NICIdar Energy, jBWR Steiam
~2H5Hp~dDrye Jnte-grity, 11evlston I Novemter 9, 2004.
NEC Joram NRC, "NRC Information Notice 2002-26, Supplement 2: Additional Flow- 7/23/08 ,V" J-ll56 Hopenfeld Induced Vibration Failures After a Recent Power Uprate" (January. 9, 2004). Tr at 1189 EC-
- Joram Email from Rick Ennis, "FWD: VY Steam Dryer Crack Info" (April 16, 7/23/08 V JH_57 Hopenfeld 2004). Tr. at 1189 NEC- Joram NRC, "Vermont Yankee Nuclear Power Station - NRC Integrated Inspection 7/23/08 V, JH_58 Hopenfeld Report 05000271/200403" (July 26, 2004). Tr. at 1189 NEC- Joram Entergy, "Condition Report," CR-VTY-2007-02133 (May 28, 2007). 7/23/08 V JH_59 Hopenfeld Tr. at 1189 NEC- Joram Vermont Public Service Board Docket Number 7195, Excerpt from Transcript 7/23/08 V/
JH-_60 Hopenfeld of Technical Hearing re: Reliability of Steam Dryer and Resulting Tr. at 1189 Performance of VT Yankee Under Uprate Conditions (August 18, 2006).
NEC- Joram Declaration of John R. Hoffman in Support of Entergy's Motion for Summary 7/23/08 V JH_61 Hopenfeld Disposition of NEC Contention 3 (April 18, 2007). Tr. at 1189
NEC- Joram NRC, "Summary of Telephone Conference Call Held on August 20, 2007, 7/21/08 V/
JH-_62 Hopenfeld between the U.S. Nuclear Regulatory Commission and Entergy Nuclear Tr. at 779 Operations, Inc., Concerning the Vermont Yankee Nuclear Power Station License Renewal Application" (October 25, 2007).
NEC- Joram Electric Power Research Institute ("EPRI"), "Materials Reliability Program: 7/21/08 V/
JH_64 Hopenfeld Guidelines for Addressing Fatigue Environmental Effects in a License Tr. at 779 Renewal Application (MRP-47, Revision 1)" (September, 2005).
NEC- Joram EPRI, "R&D Status Report: Nuclear Power Division," EPRIJournal 7/21/08 /
JH_65 Hopenfeld (January/February 1983): 52-54. Tr. at 779 NEC- Joram Wire, Gary L. and William J. Mills, "Fatigue Crack Propagation Rates for 7/21/08 /,
JH_66 Hopenfeld Notched 304 Stainless Steel Specimens in Elevated Temperature Water," Tr. at 779 JournalofPressure Vessel Technology 126 (August 2004): 318-326.
NEC-. Joram US NRC Docket Numbers 50-247-LR and 50-286-LR, "New York State's "*
JH_67 Hopenfeld Supplemental Citation in Support of Admission of Contention 26A" (May 22, 2008).
NEC- Joram Entergy, "Condition Report: Steam Dryer Inspection Indications." CR-VTY- 7/21/08 "
JH_68 Hopenfeld 2007-02133 (May 28, 2007). Tr. at 779 NEC- Joram Simonen, Fredric A. and Stephen R. Gosselin, "Life Prediction and 7/21/08 V/
JH_69 Hopenfeld Monitoring of Nuclear Power Plant Components for Service-Related Tr. at 779 Degradation," Journalof Pressure Vessel Technology 123 (February 2001):
58-64.
NEC- Joram Tennessee Valley Authority, "Memorandum: Sequoyah Nuclear Plant Units 1 7/21/08 /
JR_70 Hopenfeld and 2 - Preliminary Report on the Condensate-Feedwater Piping Inspection - Tr. at 779 Suspected Erosion-Corrosion Areas" (January 27, 1987).
NEC- Joram Bignold, G.J. et al, "Paper 1," Water Chemistry II, BNES (1980): 5-18. 7/21/08 /
JH_71 Hopenfeld - Tr. at 779
NEC- Joram Woolsey, I.S. et al, "Paper 96: The Influence of Oxygen and Hydrazine on the 7/21/08 V JH_72 1-lopenfeld Erosion-Corrosion Behaviour and Electrochemical Potentials of Carbon Steel Tr. at 779 under Boiler Feedwater Conditions," Water Chemistry of NuclearReactor Systems 4 (1986): 337-44.
NEC- Rudolf Curriculum Vitae of Rudolf Hausler 7/23/08 V RH-02 Hausler Tr. at 1434 NEC- Rudolf Rudolf Hausler, "Discussion of the Empirical Modeling of Flow-Induced 7/23/08 V RH_03 Hausler Localized Corrosion of Steel under High Shear Stress" (April 25, 2008). Tr. at 1434 NEC- Rudolf Rudolf Hausler, "Flow Assisted Corrosion (FAC) and Flow Induced Localized 7/23/08 V RH_05 Hausler Corrosion: Comparison and Discussion" (June-2, 2008). Tr, at 1434 NEC- Ulrich Curriculum Vitae of Ulrich Witte 7/23/08 V UW_02 Witte Tr. at 1436 NEC- Ulrich. Ulrich Witte, "Evaluation of Vermont Yankee Nuclear Power Station License 7/23/08 V UW_03 Witte Extension: Proposed Aging Management Program for Flow Accelerated Tr. at 1436 Corrosion" (April 25, 2008).
NEC- Ulrich NRC, "Clinton Power Station NRC Inspection Report 50-461/02-10(DRS)" 7/23/08 V UW-04 Witte (January 24, 2003). Tr. at 1436 NEC- Ulrich NRC, "Generic Aging Lessons Learned (GALL) Report: Tabulation of 7/23/08 V UW_05 Witte Results," NUREG-1801, Vol. 2,.Rev. 1 (September 2005) (Excerpt). Tr. at 1436 NEC- Ulrich "Verification of VYNPS License Renewal Project Report: Aging Management 7/23/08 V/
UW_06 Witte Program Evaluation Results," Report #LRPD-02 (May 9, 2006). Tr. at 1436 NEC- Ulrich VT Yankee, "Cornerstone Rollup: Flow Accelerated Corrosion'" (October 3, 7/23/08 V UW_07 Witte 2006) Tr. at 1436 NEC U............ t:*.... ..
FAS I NTERGYEXH1B1T E4-27: Letter frmDouglas Munson to UN'08- Witte JAnies Fitzpatrick re: Review of the Vermont YNiaik-eeNuclear Plan~flow -
______ ______ 'Accelerate~dCorrosioProgram (February 28, 2000).- [PROPRIETARY] .
NEC- Ulrich SAME AS ENTERGY EXHIBIT E4-26: Entergy Quality Assurance UW 09 Witte Division, "Engineering Programs," Audit No. QA-8-2004-VY-l (November 22,2004).
NEC Ulrich Entergy, "Condition Report: CHECWORKS predictive models for Piping 7/23/08 UW 10 Witte
./
FAC Inspection Program not updated as required per Appendix D ofPP7028,"
Tr. at 1436 CR-VTY-2005-02239 (July 28, 2005).
NEC Ulrich NRC, Official Transcript of ACRS Subcommittee on Plant License Renewal 7/23/08 UW 11 Witte ./
(June 5, 2007).
Tr. at 1436 NEC Ulrich Entergy, "Nuclear Management Manual: Flow Accelerated Corrosion 7/23/08 UW 12 Witte
./
Program" (March 9,2006).
Tr. at 1436 NEC Ulrich Chockie Group International, "Aging Management and Life Extensions in the UW 13 Witte 7/23/08 ./
US Nuclear Power Industry" (October 2006) (Excerpt). Tr. at 1436 NEC Ulrich Email from Beth Sienel to Jonathan Rowley, "re: Update to CHECWORKS" 7/23/08 UW 14 Witte
./
(February 20, 2008).
Tr. at 1436 NEC Ulrich L.E. Hochreiter, "Data Collection of Pipe Failures Occurring in Stainless Steel UW 15 Witte 7/23/08 ./
and Carbon Steel Piping," NucE 597D - Prqject 1 (April 2005)
Tr. at 1436 (CORRECTED).
NEC Ulrich EPRI, "Chapter 4: Recommendation for F'AC Tasks." [PROPRIETARY] 7/23/08 UW 16 Witte ./
Tr. at 1436 NEC Ulrich UW 17 Witte Entergy, Letter to NRC re: Extended Power Uprate: Response to Request 7/23/08 ./
for Additional Information (July 2,2004). [pROPRIETARY] Tr. at 1436 NEC Ulrich Union of Concerned Scientists, "Power Uprate History." 7/23/08 UW 18 Witte ./
Tr. at 1436 NEC Ulrich SAME AS ENTERGY EXHIBIT E4-34: Vermont Yankee Nuclear Power UW 19 Witte Station, "PP7028: Piping Flow Accelerated Corrosion Inspection Program" (May 10,2001).
NEC- Ulrich Vermont Yankee Nuclear Power Station, "PP7028: Piping FAC Inspection 7/23/08 /
UW-20 Witte Program - FAC Inspection Program. Records for 2005 Refueling Outage." Tr. at 1436 (CORRECTED)
NEC- Ulrich Betsy Thatcher, "Second Victim Dies of Burns from Power Plant Explosion," 7/23/08 "
UW-21 Witte Milwaukee Sentinel, March 9, 1995. Tr. at 1436-NEC- Ulrich NRC, "Issue 139: Thinning of Carbon Steel Piping in LWRs (Rev. 1)" 7/23/08 V UW_22 Witte (February 23, 2007). Tr. at 1436 NEC- Ulrich Union of Concerned Scientists, "Nuclear Near-Misses" (May 30, 2008).
UW 24 Witte NEC- Ulrich Union of Concerned Scientists, "Shutdowns" (May 27,'2008). -
UW 25 Witte NEC- Ulrich "NRC Audit 10/9/07, with Responses Provided 10/18/07". (October, 2007) V/
UW 26 Witte
- Striken in response to motion in limine.