DOCKETED USNRC August 12, 2008 (11:00am)

OFFICE OF SECRETARY RULEMAKINGS AND ADJUDICATIONS STAFF EXHIBIT B ua NUCLEAR REGULA1A*

(udt5-.,, ouwdt o

REJECTED WITHDRAWN n zO

NRC: Approved Applications for Power Uprates Page I ofA lGoogle Custom Search 0 j Search Options FAQ I Facility Info I Reading Rm I New I Help I Glossary I Contact Us I

About NRC I

Nuclear

.Nuclear Radioactive I

A Reactors Materials I

Waste I

Nuclear I Public Meetings I Security I & Involvement Power Uprates Approved Applications Pending Applications Expected Applications Home > Nuclear Reactors > Operating Reactors >.Licensing,> Power Uprates > Approved Applications Approved Applications for Power. Uprates The following power uprates have been reviewed and accepted by the NRC. The licenses for the following plants have been amended to reflect the increase in power level shown in the table.

(TYPE -- S Stretch; E = Extended; MU = Measurement Uncertainty Recapture)

The following links on this page are to documents in our Agencywide Documents Access and Management System (ADAMS). ADAMS documents are provided in either Adobe Portable Document Format (PDF) or Tagged Image File Format (TIFF). To obtain free viewers for displaying these formats, see our Plugins, Viewers, and Other Tools. If you have problems with viewing or printing documents from ADAMS, please contact the Public Document Room staff.

NO.

PLANT

% UPRATE MWt DATE APPROVED TYPE ACCESSION #

1 Calvert Cliffs 1 5.5 140 09/26/77 S

2 Calvert Cliffs 2 5.5 140 11/08/77 S

3 Millstone 2 5

140 06/25/79 S

7907240100*

4 H. B. Robinson 4.5 100 06/29/79 S

7907180064*

5 Fort Calhoun 5.6 80 08/15/80 S

8008280223*

6 St. Lucie 1 5.5 140 11/23/81 S

ML013530273 7

St. Lucie 2 5.5 140 03/01/85 S

ML013600080 8

Duane Arnold 4.1 65 03/27/85 S

ML021890435 9

Salem 1 2

73 02/06/86 S

ML011660249 10 North Anna 1 4.2 118 08/25/86 S

ML013460131 11 North Anna 2 4.2 118 08/25/86 S

ML013460131 12 Callaway 4.5 154 03/30/88 5

ML021650524 13 TMI-1 1.3 33 07/26/88 S

ML003779786 14 Fermi 2 4

137 09/09/92 S

ML020720520 15 Vogtle 1 4.5 154 03/22/93 5

ML012330056 16 Vogtle 2 4.5 154 03/22/93 S

ML012330056 17 Wolf Creek 4.5 154 11/10/93 S

ML022030519 18' Susquehanna 2 4.5 148 04/11/94 S

ML010170334 19 Peach Bottom 2 5

165 10/18/94 S

ML011490143 20 Limerick 2 5

165 02/i6/95 S

ML011560773 21 Susquehanna 1 4.5 148 02/22/95 S

9503070354*

22 Nine Mile Point 2 4.3 144 04/28/95 S

9505090259*

http://www.nrc.gov/reactors/operating/licensing/power-uprates/approved-applications.html 6/2/2008

NRC: Approved Applications for Power Uprates Page 2 cf' 4 23 WNP-2 4.9 163 05/02/95 S

ML022120154 24 Peach Bottom 3 54

-165.

07/18/95 S

ML021580312

.25.

Surry 1 4.3 105.

08/03/95 S

INL0.1271VI28 26 Surry 2 4.3 105 08/03/95 S

ML012710328 27 Hatch 1 5

122 08/31/95 S

ML013020073 28 Hatch 2 5

122 08/31/95 S

ML013020073 29 Limerick 1 5

165 01/24/96 S

ML011560244 30 V. C. Summer 4.5 125 04/12/96 S

ML012320013 31 Palo Verde 1 2

76 05/23/96 5

ML021710572 32 Palo Verde 2 2

76 05/23/96 S

ML021710572 33 Palo Verde 3 2

76 05/23/96 S

ML021710572 34 Turkey Point 3 4.5 100 09/26/96 S

ML013390234 35 Turkey Point 4 4.5 100 09/26/96 S

ML013390234 36 Brunswick 1 5

122 11/01/96 S

9611070136*

37 Brunswick 2 5

122 11/01/96 5

9611070136*

38 Fitzpatrick 4

100 12/06/96 S

9612180303*

39 Farley 1 5

138 04/29/98 S

ML012140259 40 Farley 2 5

138 04/29/98 S

ML012140259 41 Browns Ferry 2 5

164 09/08/98 5

ML042670045 42 Browns Ferry 3 5

164 09/08/98 S

ML042670045 43 Monticello 6.3 105 09/16/98 E

ML020920138 44 Hatch 1 8

205 10/22/98 E

ML013030084 45 Hatch 2 8

205 10/22/98 E

ML013030084 46 Comanche Peak 2 1

34 09/30/99 MU ML021820306 47 LaSalle 1 5

166 05/09/00 S

ML003716743 48 LaSalle 2 5

166 05/09/00 S

ML003716743 49 Perry 5

178 06/01/00 S

ML003724441 50 River Bend 5

145 10/06/00 S

ML003762072 51 Diablo Canyon 1 2

73 10/26/00 S

ML003764792 52 Watts Bar 1.4 48 01/19/01 MU ML010260074 53 Byron 1 5

170 05/04/01 S

ML011420274 54 Byron 2 5

170 05/04/01 S

ML011420274 55 Braidwood 1 5

170 05/04/01 S

ML011420274 56 Braidwood 2 5

170 05/04/01 S

ML011420274 57 Salem 1 1.4 48 05/25/01 MU ML011350051 58 Salem 2 1.4 48 05/25/01 MU ML011350051 59 SanOnofre2 1.4 48 070/6/01 MU ML012180231 60 San Onofre 3 1.4 48 07/06/01 MU ML012180231 61 Susquehanna 1 1.4 48 07/06/01 MU ML011760551 62 Susquehanna 2 1.4 48 070/6/01 MU ML011760551 http://www.nrc.gov/reactors/operating/licensinglpower-uprates/approved-applications.html 6/2/2008

NlIC: Approved Applications for Power Uprates Page 3 o " 42 63 Hope Creek 1.4 46 07/30/01 MU ML011910345 64 Beaver Valley 1 1.4 37 09/24/01 MU ML012490569 65 Beaver Valley 2 1.4 37 09/24/0i MU ML012490569 66 Shearon Harris 4.5 138 10/12/01 S

ML012830516 67 Comanche Peak 1 1.4 47 10/12/01 MU ML012550246 68 Comanche Peak 2 0.4 13 10/12/01 MU ML012550246 69 Duane Arnold 15.3 248 11/06/01 E

ML013050342 70 Dresden 2 17 430 12/21/01 E

ML013540187 71 Dresden 3 17 430 12/21/01 E

ML013540187 72 Quad Cities 1 17.8 446 12/21/01 E

ML013540222 73 Quad Cities 2 17.8 446 12/21/01 E

ML013540222 74 Waterford 3 1.5 51 03/29/02 MU ML020910734 75 Clinton 20 579 04/05/02 E

ML021650543 76 South Texas 1 1.4 53 04/12/02 MU ML020800263 77 South Texas 2 1.4 53 04/12/02 MU ML020800263 78 ANO-2 7.5 211 04/24/02 E

ML021130826 79 Sequoyah 1 1.3 44 04/30/02 MU ML021220060 80 Sequoyah 2 1.3 44

.04/30/02 MU ML021220060 81 Brunswick 1 15 365 05/31/02 E

ML021440346 82 Brunswick 2 15 365 05/31/02 E

ML021440346 83 Grand Gulf 1.7 65 10/10/02 MU ML022630304 84 H. B. Robinson 1.7 39 11/05/02 MU ML023100365 85 Peach Bottom 2 1.62 56 11/22/02 MU ML031000317 86 Peach Bottom 3 1.62 56 11/22/02 MU ML031000317 87 Indian Point 3 1.4 42.4 11/26/02 MU ML023290636 88 Point Beach 1 1.4 21.5 11/29/02 MU ML023370133 89 Point Beach 2 1.4 21.5 11/29/02 MU ML023370133 90 Crystal River 3 0.9 24 12/04/02 S

ML023380800 91 D.C. Cook 1 1.66 54 12/20/02 MU ML023470126 92 River Bend 1.7 52 01/31/03 MU ML030340294 93 D.C. Cook 2 1.66 57 05/02/03 MU ML030990129 94 Pilgrim 1.5 30 05/09/03 MU ML031220007 95 Indian Point 2 1.4 43 05/22/03 MU ML031420375 96 Kewaunee 1.4 23 07/08/03 MU ML031530734 97 Hatch 1 1.5 41 09/23/03 MU ML032590944 98 Hatch 2, 1.5 41 09/23/03 MU ML032590944 99 Palo Verde 2 2.9 114 09/29/03 S

ML032720538 100 Kewaunee 6

99 02/27/04 S

ML040430633 101 Palisades 1.4 35.4 06/23/04 MU ML040970622 102 Indian Point 2 3.26 101.6 10/28/04 S

ML042960007 http://www.nrc.gov/reactors/operating/licensing/power-uprates/approved-applications.html 6/2/2008

NRC: Approved Applications for Power Uprates Page 4 of 4 103 ISeabrook 5.2 176 02/28/05 S

ML050140453 9

I 104 1Indian Point 3 4.85 148.6 03/24/05 S

ML050600380 104 llndian Point 3 03/24/05 ML050600380 I

.1 ~

~

105 1Waterford 8.0 275 04/15/05 E

ML031030068 9 -

==

~-.~='~=-=

106 1Palo Verde 1 2.9 114 11/16/05 S

ML053130286 107 Palo Verde 3 2.9 114 11/16/05 S

ML053130286 108 Vermont Yankee 20 319 03/02/06 E

ML060050024 109 Seabrook 1.7 61 05/22/06 MU ML061430044 110 Ginna 16.8 255 07/11/06 E

ML061380133 111 Beaver Valley 1 8

211 07/19/06 E

ML061720274 112 Beaver Valley 2 8

211 07/19/06 E

ML061720274 113 Browns Ferry 1 5

165 03/06/07 S

ML070680307 114 Crystal River 3 1.6 41 12/26/07 MU ML073610197 115 Susquehanna 1 13 463 01/30/08 E

116 Susquehanna 2 13 463 01/30/08 E

117 Vogtle 1 1.7 60.6 02/27/08 MU ML080350345 118 Vogtle 2 1.7 60.6 02/27/08 MU ML080350345 Total MWt 15788.2 Total MWe 5263

  • Documents can be requested from the Public Document Room Capacity Recapture Power Uprates for Provisional Operating License Plants are not included in this table. These are Haddam Neck uprate of 24% in 1969, Oyster Creek uprate of 14% in 1971, Palisades uprate of 15% Fri 1977, Ginna uprate of 17% in 1984, Maine Yankee uprate of 10% in 1989, and Indian Point 2 Uprate of 11% in 1990.

NOTE:The NRC staff approved an MUR power uprate for Fort Calhoun on January 16, 2004, which authorized an increase in the licensed thermal power limit to 1,524 megawatts-thermal.

The Omaha Public Power District was subsequently informed by Westinghouse that the potential instrument inaccuracies in the Advanced Measurement and Analysis Group (AMAG) ultrasonic flow meter would not allow implementation of the MUR power uprate at Fort Calhoun. As a result, on May 7, 2004, prior to implementation of the MUR power uprate, the Omaha Public Power District submitted an exigent license amendment request to return Fort Calhoun's licensed thermal power limit to 1,500 megawatts-thermal, the pre-MUR level. On May 14, 2004, the NRC staff approved this license amendment.

Privacy Policy I Site Disclaimer Wednesday, May 21, 2008 http://www.nrc.gov/reactors/operating/licensing/power-uprates/approved-applications.htm]

6/2/2008