L-PI-08-070, Response to Acceptance Review Questions Re License Amendment Request for Technical Specifications Changes to Allow Use of Westinghouse 0.422-inch OD 14X14 Vantage+ Fuel
| ML082210260 | |
| Person / Time | |
|---|---|
| Site: | Prairie Island (DPR-042, DPR-060) |
| Issue date: | 08/04/2008 |
| From: | Wadley M Nuclear Management Co |
| To: | Document Control Desk, Office of Nuclear Reactor Regulation |
| References | |
| L-PI-08-070, TAC MD9142, TAC MD9143 | |
| Download: ML082210260 (60) | |
Text
1717 Wakonade Drive East
- Welch, Minnesota 55089-9642 Telephone: 651.388.1121 August 4, 2008 L-PI-08-070 10CFR50.90 U.S. Nuclear Regulatory Commission ATTN: Document Control Desk Washington, DC 20555 Prairie Island Nuclear Generating Plant Units 1 and 2 Dockets 50-282 and 50-306 License Nos. DPR-42 and DPR-60 Response to Acceptance Review Questions Re : License Amendment Request for Technical Specifications Changes to Allow Use of Westinghouse 0.422-inch OD 14X14 VANTAGE+ Fuel (TACs MD9142/MD9143)
Reference:
Letter from Michael D. Wadley (NMC) to Document Control Desk (NRC),
License Amendment Request for Technical Specifications Changes to Allow Use of Westinghouse 0.422-inch OD 14x14 VANTAGE+ Fuel, dated June 26, 2008 (ADAMS Accession ML081820137)
Nuclear Management Company, LLC (NMC) hereby transmits supplemental information in support of the previously submitted request for amendment to Prairie Island Nuclear Generating Plant (PINGP)(Reference). On July 22, 2008, the NRC staff provided NMC several acceptance review questions which were required to be addressed prior to the staffs completion of the acceptance review for the amendment request. The requested supplemental information to address the NRC comments is provided in Enclosures 1 and 2. Enclosure 1 provides responses to Questions 1 through 5. Enclosure 2 provides the analysis performed in support of the response to Question 5.
The supplemental information provided does not affect the No Significant Hazards Determination analysis provided by NMC in the referenced License Amendment Request. Pursuant to 10 CFR 50.91(b)(1), NMC has provided a copy of this letter to the appropriate state representative.
Prairie Island Nuclear Generating Plant Operated by Nuclear Management Company, LLC
Document Control Desk Page 2 Summary of Commitments This letter makes no new commitments and no revisions to existing commitments.
Should you have any questions regarding the information in this submittal, please contact Leonard Sueper at (612) 330-6917.
I declare under penalty of perjury that the foregoing is true and correct.
Executed on August 4, 2008.
Michael D. Wadley Site Vice President, Prairie Island Nuclear Generating Plant Nuclear Management Company, LLC Enclosures (2) cc: Administrator, Region Ill, USNRC Project Manager, Prairie Island Nuclear Generating Plant, USNRC Resident Inspector, Prairie Island Nuclear Generating Plant, USNRC State of Minnesota Department of Commerce
Page 1 of 5 Response to Acceptance Review Questions Re : License Amendment Request for Technical Specifications Changes to Allow Use of Westinghouse 0.422-inch OD 14X14 VANTAGE+ Fuel (1) Please clarify the difference between "evaluate" and "analyze" as discussed in Chapter 5 of the licensing report. For those sections that discuss particular analyses, it is clear what the analysis entailed. For evaluations, however, the NRC staff seeks to understand how the licensee assured itself that reanalysis was not required. Please provide a summary of the evaluation technique used.
The Westinghouse reload methodology (WCAP-9272-P-A) is based on the use of bounding analysis input assumptions which are then evaluated for continued conservatism on a cycle-specific basis. The bounding nature of these parameters leads to the use of parameter values that are often applicable to a variety of fuel types.
With respect to the Westinghouse 0.422-inch OD 14X14 VANTAGE+ Fuel (422V+) fuel transition at the Prairie Island Nuclear Generating Plant, the majority of the previously defined fuel-related input to the safety analyses was determined to remain bounding. For parameters with the input value unchanged, the results of any subsequent analyses would likewise be unchanged. For those parameter input values that were determined to no longer be bounding for operation with 422V+ fuel, an event-by-event evaluation of the modified value was performed.
Additional details of this evaluation are provided below. It should be noted that the Westinghouse Quality Assurance requirements for an evaluation are identical to the requirements for an analysis in that both must meet the same documentation standards, be performed by a qualified author, reviewed by a qualified and independent verifier, and require appropriate management signoff.
The event-by-event evaluation included an initial determination as to whether or not the modified parameter was modeled in the analyses for each event. For those events that used a particular parameter, the evaluation determined if the new value associated with a modified parameter was conservative with respect to the analysis of record for that event. For example, the predicted departure from nucleate boiling ratio (DNBR) at nominal conditions was increased for operation with 422V+ fuel. Since an increase in the DNBR at nominal conditions would lead to an increase in the transient DNBR (including the transient minimum DNBR) for all DNB events, it was concluded that this change was conservative and no further action was necessary to address the change.
Page 2 of 5 An assessment of the impact was made for each affected event from parameter changes that were determined to be non-conservative with respect to the previous bounding fuel parameters. For example, the bounding maximum fuel temperatures as a function of linear power are used to define minimum fuel-to-coolant heat transfer characteristics. The maximum fuel temperatures for the transition to 422V+ fuel are more limiting than those previously specified. The minimum fuel-to-coolant heat transfer characteristics are modeled in the Loss of External Electrical Load analysis. However, since the change in core heat flux during the transient is relatively small for this event, it was concluded that the minimum DNBR and maximum system pressures would be minimally impacted by the resulting change as the fuel-to-coolant heat transfer would be essentially constant and thus not impacted by a change in the heat transfer characteristics.
In all instances, the reactor coolant system (RCS) and main steam system (MSS) transient responses associated with the events listed in Table 5.1-1 of the licensing report as being addressed via evaluation (i.e., identified via a 2 in the Notes column) were determined to be insignificantly impacted by any of the parameter changes required by the fuel transition.
There were events that were addressed for the fuel transition by performing a complete analysis. For example, it was determined that the fuel geometry and/or the associated pressure drop through the core could have a significant impact on the transient responses for certain events such that the acceptance criteria could be challenged. Thus, analyses were performed for each of these events which resulted in acceptable results as described in Section 5.1 of the licensing report.
(2) The excessive load increase section retains generic, boiler-plate language referring to general Westinghouse design features. Please clarify whether these design features (step and ramp load increase capabilities) apply to Prairie Island.
The load change capabilities defined as typical in Attachment 4 section 5.1.7 are applicable to Prairie Island. Specifically, the typical design features of 10 percent step and 5 percent per minute ramp load changes apply to Prairie Island.
The Prairie Island Updated Safety Analysis Report (USAR) Section 7.2.1 defines the Reactor Control System design as capable of responding to a 10 percent step change and a 5 percent per minute ramp change without a reactor trip.
(3) Section 5.2.4 of the licensing report states, "a post-LOCA core boric acid precipitation analysis was most recently performed as part of the Safety Analysis Transition Program/RSG Program (Reference 24)." The mentioned reference does not discuss this analysis. Please supplement the licensing report with a comprehensive discussion of post-LOCA long term core cooling, including the following:
Page 3 of 5
- Discussion of different cases and scenarios analyzed
- Modeling assumptions and their impact on boric acid solubility and precipitation
- Description of thermal/hydraulic behavior in the lower plenum mixing volume, if credited
- Limiting times for manual recovery actions, including the types of actions, minimum initiation times, and maximum initiation times
- Predictions, calculations, and analyses of the behavior of various recovery systems, including RWST, SI accumulators, sump mixing behavior during recirculation, etc.
The NRC has subsequently determined that the request for supplemental information pertaining to calculations for the post-LOCA long-term core cooling and post-LOCA core boric acid precipitation analyses are not required for acceptance of the application.
On July 24, 2008, the NRC staff performed a cursory review of the requested calculations during an audit at the Westinghouse office in Rockville, Maryland.
The staff concluded from this audit that sufficient technical information exists to commence a detailed LOCA analyses review.
(4) Section 2.5 Seismic/LOCA Impact on Fuel Assemblies: The approved Westinghouse methodology to analyze the seismic and LOCA loading is WCAP-9401. Provide justification of the NKMODE and WECAN codes.
Also, provide the analytical description and results for mixed core.
NKMODE is a pre-processor tool utilized to establish an equivalent finite element model that will preserve the dynamic properties of the fuel assembly. The NKMODE fuel assembly model is further verified by using the general purpose finite element code, WECAN. Such a model is described in the licensed methodology, WCAP-9401-P-A/WCAP-9402-A, where the dynamic characteristics of the fuel assembly were modeled and analyzed using general purpose finite element computer codes. Appendix A of WCAP-9401-P-A/WCAP-9402-A describes an example (NRC sample problem) analysis where assumed damping coefficients and a lumped mass-spring system were used to construct a simplified fuel assembly finite element model. The representative simplified fuel assembly model shown in WCAP-9401-P-A/WCAP-9402-A Appendix A is consistent with a full assembly model of the same characteristics as constructed by NKMODE.
The methods utilized by the WECAN computer code are described in detail in WCAP-9401-P-A/WCAP-9402-A. It is considered to be a general purpose finite element code verifiable by hand calculations or other equivalent finite element
Page 4 of 5 codes such as ANSYS. The following text from the safety evaluation regarding WCAP-9401-P-A/WCAP-9402-A supports that conclusion:
"Although the WECAN computer code used in the systems analysis was not directly audited, the code has been benchmarked against hand calculations and problems in the open literature and is presently under review by the NRC staff and projected to have a favorable safety evaluation."
The response to the question on the modeling of the mixed core is as follows:
The mixed core effects were specifically examined to ensure that the interactions between the resident Westinghouse 0.400 Vantage+ (400V+) fuel and the new 422V+ fuel were captured. Each row of the core (3 assemblies, 7 assemblies, 9 assemblies, 11 assemblies and 13 assemblies) was modeled with different combinations of the resident 400V+ and new 422V+ fuel to encompass any expected core reload configuration. The limiting combinations analyzed included each row independently modeled with the resident 400V+ assembly on the baffle location and the inner assemblies modeled as the new 422V+ assemblies. In addition, the new 422V+ assemblies were placed on the baffle location for each row and the inner assemblies were modeled with the current 400V+ fuel assemblies. This ensures that the baffle-assembly and assembly-to-assembly interfaces for each combination of the fuel were addressed. This bounds any combination of the two fuel types and ensures that the analyses remain valid and that the conclusions of the USAR remain valid.
In addition to the above it should be noted that mixed core effects, including the seismic/LOCA effects, are addressed in the approved supplement to WCAP-9401/9402 and WCAP-9500 entitled "Supplemental Information for NRC Approved Version of WCAP-9401/9402 and WCAP-9500," dated February 1983.
(5) Are the core isotopics based on Westinghouse 14x14 VANTAGE+ fuel, as calculated using an approved isotopic depletion/generation code (e.g.,
ORIGEN), bounded by the core isotopics calculated for the current design basis accident analyses using the currently licensed fuel type?
Nuclear Management Company addressed the impacts of this new fuel type based on dose potential as opposed to comparing core isotopics. To accomplish this, new ORIGEN-S runs were created for both fuel types using a consistent set of inputs with the exception of the differences due to the two different fuel designs. This resulted in isotopic differences that were due only to the fuel type change (as opposed to unanticipated variations due to older code versions, operating assumptions, assumed cycle length, input errors etc). The results of these two ORIGEN-S runs were processed through a representative plant model for Prairie Island using appropriate accident assumptions and consideration of external dose for equipment qualification (EQ). The evaluation concluded the
Page 5 of 5 422V+ fuel did not result in any increase in dose potential as compared to the existing 400V+ fuel type. A summary of this conclusion is included in Enclosure 1 to the license amendment request Section 2.5 (Reference). Based on the conclusion that the dose consequences were not negatively impacted by the new fuel type, no radiological analyses were rerun and submitted with this license amendment request.
presents the calculations completed to support this conclusion. For the purposes of this calculation, the fuel designated as OFA is the same as 400V+ fuel.
52 pages follow Prairie Island Dose Consequence Evaluation
PSAT 3 142CT.QA.04 CALC:WLATIOX TITLE PAGE CALCULATION hrtWBER: PSAT 3 1 42CT.Qa4.04 "Calculatian and Compgsou of Dose Patential for PINGP OFA Fuel vs. Heavy BttndIe FueL'"
ORTGINATOR, CHECKER IND REk'IEWR PrhttSian
-- Date PrlnfiSign D.flte PkUSi.m lJ&
RE'klSrON: 0 James Metcalf Heather Lucek Heather Lucek
PSAT 3142CT.QA.04 Page 2 of 27 Rev. 0 1 2 3 4 REASON FOR REVISION:
Nonconformance Rpt 0 Initial Issue N/A
PSAT 3142CT.QA.04 Page 3 of 27 Rev. 0 1 2 3 4 Table of Contents Section Page Purpose 3
Methodology 3
Assumptions 5
Design Inputs 5
References 10 Calculation 11 Results 26 Conclusion 27 Appendices Aa and Ab - LIBFILE1.TXT files (2 pages each)
Appendix B - INPUT.DAT for Prairie Island Nuclear Generating Plant (5 pages)
Appendix C - Excerpts of RESULTS.OUT files for STARDOSE Analyses (11 pages)
Appendix D - MicroShield Analysis for Long-Term EQ Dose Rates (5 pages)
Purpose The purpose of this calculation is to establish that for the Prairie Island Nuclear Generating Plant (PINGP), OFA fuel bounds the dose potential of Heavy Bundle fuel for a dose analysis conforming to Regulatory Guide 1.4 [1] and TID-14844 [2].
Methodology The methodology applied is as follows:
- Radionuclide information is compiled in the form of a STARDOSE [3] library file (LIBFILE1.TXT) based on RADTRAD [4] inputs for:
(1) dose conversion factors (DCFs) for cloud immersion and inhalation (thyroid and CEDE),
(2) decay constants, and
PSAT 3142CT.QA.04 Page 4 of 27 Rev. 0 1 2 3 4 (3) identification of important decay daughters.
Note that the dose conversion factors in RADTRAD are based on the Federal Guidance Reports [5, 6] except that the DCFs for short-lived daughters (half-lives less than 90 minutes and also less than 10% of that of the parent) have been added to the DCFs of the parent.
Core activities are taken from Attachment 1 of reference [7] for both fuel types. Note that the core inventories are typically entered into the LIBFILE1.TXT file as Ci/MWt; in this instance, they are entered as Ci. Therefore, a core power of 1 MWt is used in the INPUT.DAT file.
The radionuclides considered represent an expansion of the nominal 60 radionuclides considered by RADTRAD. There are 77 considered including three chemical forms of iodine. Since there are six iodine isotopes considered, the actual number of isotopes considered in STARDOSE is 65. The two isotopes of cobalt considered in RADTRAD are omitted as is Te-129, so eight radionuclides are added. These include: Xe-131m, Xe-133m, Xe-135m, Xe-137, Xe-138, I-130, Rb-88, and Cs-138. The release fraction for the noble gases is 100% and that for the iodine is 25% (per reference [1]) making these eight added radionuclides far more important than the Co-58, Co-60, and Te-129 (release fractions = 1% per [1]) that have been removed. Rb-88 and Cs-138 are included as noble gas daughters (as well as Cs-137 which is already included in the RADTRAD list).
- Using the same information as that used above to prepare the STARDOSE LIBFILE1.TXT file, a spreadsheet is prepared in which the activity released according to the Maximum Hypothetical Accident (MHA) release fractions of reference [1] are integrated over t = 0 to t = 30 days using the expression A0(1-e-t)/ (where A0 is the activity at t = 0 and is the decay constant) and then multiplied by the relevant DCF to obtain rem-sec for inhalation doses and rem-m3 for immersion doses. The inhalation product is then also multiplied by an assumed breathing rate of 3.5E-4 m3/sec to obtain rem-m3. The quantity rem-m3 is a dose index that when multiplied by the dilution due to dispersion (so-called /Q in units of sec/m3) and the fractional release rate to the environment over the 30 days (in units of /sec) provides the dose contribution in rem. By comparing the summation of dose indices, the relative dose potential for two core inventory sets can be estimated.
- The dose potential is confirmed using a STARDOSE plant model (INPUT.DAT) for PINGP prepared in accordance with Attachment 3 of reference [7]. It is important to note that this is not a licensing-basis model for PINGP - it is intended only to be representative of PINGP in order to confirm the relative dose potential of two core inventory sets, not the absolute dose result. Note that the 1% other release of reference [1] is considered to be airborne in the STARDOSE modeling applied herein. This is not required for the MHA offsite dose calculation of reference [1].
- The STARGATE code [8] has been used to extract the non-noble gas activities from the Airborne location for the containment (Control Volume PC in the STARDOSE model)
PSAT 3 142CT.QA.04 Page 5 of 27
~ e v. [ 1 2 3 4 at the end of the release to the containment (assumed to last two seconds). STARGATE creates inpuit files for MicroShield 7.02 [9]. MicroShield is then run to obtain photons per second by energy group at t = 90 days and t = 180 days. These are compared to supplement the comparison of non-noble gas whole body dose indices integrated over 30 days. In this way, the equipment qualification (EQ) aspects for the non-noble gas radionuclides (i.e., waterborne sources) can be compared beyond 30 days.
Assumptions Assumption I: It is assumed that whatever multiplier would be applied to the OFA fuel core inventory (e.g., for fuel management flexibility) would also be applied to that for HB fuel.
Justification: See reference [7], Attachment 2.
Design Inputs From Reference [7]:
- 1. Core inventory for OFA fuel (Item 1.1 without any multipliers per Item 1.3):
i Tabk E.4 OF#%
Cow As81v~w Invctrr$orim I.
' - -,-*.irpt. '$IIIPLPIIF
PSAT 3 142CT.QA.04 Page 6 of 27
~ e v. [ 1 2 3 4 I
Tsbk B d iQ~omlnued I
i--
' Nuclde As.-m-To&$ Care Mtiwifs ln]rrrnbrX,Cygss--_
PSAT 3 142CT.QA.04 Page 7 of 27
~ e v. [ 1 2 3 4 ltipliers per Item 1.3):
.--w- -
PSAT 3 142CT.QA.04 Page 8 of 27 Rev. [ 1 2 3 4
PSAT 3 142CT.QA.04 Page 9 of 27
~ e v. [ 1 2 3 4
- 3. Primary containment volume = 1.32E6 ft3, Item 2.1
- 4. Primary containment leakage rate = 0.25 %/day, Item 2.1 (with factor of two reduction at t = 24 hours2.777778e-4 days <br />0.00667 hours <br />3.968254e-5 weeks <br />9.132e-6 months <br /> and 0.14%/day leaked to Shield Building, O.lO%/day leaked to Auxiliary Building, and O.Ol%/day leaked directly to Environment)
- 5. Spray remov ry contai
- 6. Volume of Shield Building credited = 50% of 3.74E5 ft3 = 1.87E5 ft3, Item 2.1
- 7. Shield Building exhaustlleakage profile (Item 2.1):
b ~ &
sw snizrfcr wm w
g~.strsld B w : @ ~ h!%q WI%~%
B u l % q Exhaw@
E&ssaS kd~k~gs w % a ~ % RWG mnz.
3m PBW@
CFMk
&&-a;"
GFMI If+&- %)* rcm>
~
~
1 2
~
PSAT 3 142CT.QA.04 Page 10 of 27
~ e v. H l 2 3 4
- 8. Filtration efficiency for Shield Building exhaust and recirculation = 90% for elemental iodine, 70% for organic iodine, 99% for particulate, Item 2.1
- 9. Effective filtration for Auxiliary Building including bypass = 81.8% for elemental iodine, 63.6% for organic iodine, 90% for particulate, Item 2.1
- 10. Volume of past-accident sump = 2.67E4 ftj, Item 2.1
- 11. ESF component leakage = zero, Item 2.1
- 13. X/Qs for offsite doses Item 2.1 :
S3 B
bm.
15.83E 04 3, 'i&l-.OS 83 - 24 hra, 6,2 78-86 3 - 4 days
$.DPE-B&
4 - S Q days L 5 2 8 - O T Note that the 71 5 meter value is assumed for the EAB dose and the 8046 meter values are assumed for the LPZ dose. This assumption is not critical since only relative doses are being considered.
- 14. Breathing ra References
- 1. "Assumptions Used for Evaluating the Potential Radiological Consequences of a Loss of Coolant Accident for Pressurized Water Reactors", Regulatory Guide 1.4, June 1974.
- 2. J.J. DiNunno et al., "Calculation of Distance Factors for Power and Test Reactor Sites,"
USAEC TID-14844, U.S. Atomic Energy Commission (now USNRC), 1962
- 3. PSAT C109.05, "STARDOSE Validation Report", Revision 1 and PSAT C109.06, "STARDOSE User's Manual", Revision 1.
- 4. S.L. Humphreys, et. al., "RADTRAD, A Simplified Model for Radionuclide Transport and Removal and Dose Estimation", NUREGJCR-6604.
- 5. Federal Guidance Report No. 1 1, "Limiting Values of Radionuclide Intake and Air Concentration aind Dose Conversion Factors for Inhalation, Submersion, and Ingestion," EPA 52011 020, U.S. Environmental Protection Agency, Washington, DC, 1988.
PSAT 3142CT.QA.04 Page 11 of 27 Rev. 0 1 2 3 4
- 6. Federal Guidance Report No. 12, External Exposure to Radionuclides in Air, Water and Soil, EPA 420-r-93-081 U.S. Environmental Protection Agency, Washington, DC, 1993.
- 7. PSAT 3142CT.QA.04, "Design Database for the Comparison of OFA Fuel and Heavy Bundle Fuel MHA Source Terms for Prairie Island Nuclear Power Plant
- 8. PSAT CI18.QA.07, STARGATE Programming Report and PSAT CI18.QA.03, Dedication of MicroShield and STARGATE
- 9. PSAT CI18.QA.04, MicroShield Users Manual, Version 7, October, 2006, Grove Software, Inc. and PSAT CI18.QA.03, Dedication of MicroShield and STARGATE Calculation Dose Index Comparisons As described in the Methodology section, the following is the calculation of the radionuclide dose potential. The first column is the radionuclide name. The second is the core inventory (Ci).
The third is the Ci/MWt (for information only). The fourth is the decay constant (per second).
The fifth is the external exposure (EE) whole body (WB) DCF (rem-m3/Ci-sec). The sixth is the inhalation DCF (rem/Ci); thyroid for the thyroid dose and CEDE for the TEDE dose. The seventh is the activity integral (over 2 hours2.314815e-5 days <br />5.555556e-4 hours <br />3.306878e-6 weeks <br />7.61e-7 months <br /> or 30 days). The units of the integrated expression are rem-sec. The eighth column is the RG 1.4 release fraction. The ninth column is the product of the external exposure DCF, the activity integral, and the release fraction in units of rem-m3.
The tenth column is the product of the inhalation DCF, the breathing rate, the activity integral, and the release fraction in units of rem-m3. The breathing rate used is 3.5E-4 m3/sec.
The index sums are provided for the thyroid dose, the whole body dose due to external exposure, and the TEDE (equal to the inhalation CEDE plus the whole body dose due to external exposure). In addition, the whole body dose without noble gas is provided as an indicator of waterborne gamma exposure for EQ. Finally, for the two-hour integration period, the TEDE index is also provided for noble gas and iodine, only. This is an indicator for the Fuel Handling Accident in which only noble gas and iodine is released.
PSAT 3142CT.QA.04 Page 12 of 27 Rev. 0 1 2 3 4 Table 1 - OFA Two Hour MWt =
1650 BR =
3.50E-04 m3/s Inhalation 2-hour EE Inhalation Nuclide Activity Ci/MWt DK /sec EE DCF DCF Integral Rel fract Product Product I130 1.43E+06 8.67E+02 1.56E-05 3.85E-01 7.36E+04 9.74E+09 0.2500 9.37E+08 6.27E+10 I131 4.43E+07 2.68E+04 9.98E-07 6.73E-02 1.07E+06 3.18E+11 0.2500 5.35E+09 2.98E+13 I132 6.41E+07 3.88E+04 8.37E-05 4.14E-01 6.29E+03 3.47E+11 0.2500 3.59E+10 1.91E+11 I133 8.97E+07 5.44E+04 9.26E-06 1.09E-01 1.81E+05 6.25E+11 0.2500 1.70E+10 9.89E+12 I134 1.01E+08 6.12E+04 2.20E-04 4.81E-01 1.07E+03 3.65E+11 0.2500 4.39E+10 3.42E+10 I135 8.57E+07 5.19E+04 2.91E-05 3.07E-01 3.14E+04 5.57E+11 0.2500 4.27E+10 1.53E+12 Thyroid =
4.15E+13 MWt =
1650 BR =
3.50E-04 m3/s Inhalation 2-hour EE Inhalation Nuclide Activity Ci/MWt DK /sec EE DCF DCF Integral Rel fract Product Product Kr85m 1.06E+07 6.42E+03 4.30E-05 2.77E-02 0
6.56E+10 1.0000 1.82E+09 0.00E+00 Kr85 6.23E+05 3.78E+02 2.05E-09 4.40E-04 0
4.49E+09 1.0000 1.97E+06 0.00E+00 Kr87 2.08E+07 1.26E+04 1.51E-04 1.52E-01 0
9.13E+10 1.0000 1.39E+10 0.00E+00 Kr88 2.77E+07 1.68E+04 6.78E-05 3.77E-01 0
1.58E+11 1.0000 5.95E+10 0.00E+00 Xe131m 4.97E+05 3.01E+02 6.74E-07 1.44E-03 0
3.57E+09 1.0000 5.14E+06 0.00E+00 Xe133m 2.81E+06 1.70E+03 3.67E-06 5.07E-03 0
2.00E+10 1.0000 1.01E+08 0.00E+00 Xe133 8.99E+07 5.45E+04 1.53E-06 5.77E-03 0
6.44E+11 1.0000 3.71E+09 0.00E+00 Xe135m 1.92E+07 1.16E+04 7.56E-04 7.55E-02 0
2.53E+10 1.0000 1.91E+09 0.00E+00 Xe135 1.82E+07 1.10E+04 2.12E-05 4.40E-02 0
1.22E+11 1.0000 5.35E+09 0.00E+00 Xe137 8.09E+07 4.90E+04 2.96E-03 3.03E-02 0
2.73E+10 1.0000 8.28E+08 0.00E+00 Xe138 7.59E+07 4.60E+04 6.80E-04 2.13E-01 0
1.11E+11 1.0000 2.36E+10 0.00E+00 I130 1.43E+06 8.67E+02 1.56E-05 3.85E-01 2.64E+03 9.74E+09 0.2500 9.37E+08 2.25E+09 I131 4.43E+07 2.68E+04 9.98E-07 6.73E-02 3.29E+04 3.18E+11 0.2500 5.35E+09 9.15E+11 I132 6.41E+07 3.88E+04 8.37E-05 4.14E-01 3.81E+02 3.47E+11 0.2500 3.59E+10 1.16E+10 I133 8.97E+07 5.44E+04 9.26E-06 1.09E-01 5.85E+03 6.25E+11 0.2500 1.70E+10 3.20E+11 I134 1.01E+08 6.12E+04 2.20E-04 4.81E-01 1.31E+02 3.65E+11 0.2500 4.39E+10 4.18E+09 I135 8.57E+07 5.19E+04 2.91E-05 3.07E-01 1.23E+03 5.57E+11 0.2500 4.27E+10 5.99E+10 Rb86 1.29E+05 7.82E+01 4.30E-07 1.78E-02 6.62E+03 9.27E+08 0.0100 1.65E+05 2.15E+07 Rb88 2.83E+07 1.72E+04 6.49E-04 1.24E-01 8.36E+01 4.32E+10 0.0100 5.36E+07 1.26E+07 Cs134 1.35E+07 8.18E+03 1.07E-08 2.80E-01 4.63E+04 9.72E+10 0.0100 2.72E+08 1.58E+10 Cs136 2.91E+06 1.76E+03 6.12E-07 3.92E-01 7.33E+03 2.09E+10 0.0100 8.20E+07 5.36E+08 Cs137 6.80E+06 4.12E+03 7.32E-10 1.01E-01 3.19E+04 4.90E+10 0.0100 4.94E+07 5.47E+09 Cs138 8.31E+07 5.04E+04 3.59E-04 4.48E-01 1.01E+02 2.14E+11 0.0100 9.59E+08 7.57E+07
PSAT 3142CT.QA.04 Page 13 of 27 Rev. 0 1 2 3 4 Sb127 4.19E+06 2.54E+03 2.08E-06 1.23E-01 6.03E+03 2.99E+10 0.0100 3.68E+07 6.32E+08 Sb129 1.28E+07 7.76E+03 4.46E-05 2.64E-01 6.44E+02 7.88E+10 0.0100 2.08E+08 1.78E+08 Te127m 7.11E+05 4.31E+02 7.36E-08 5.44E-04 2.15E+04 5.12E+09 0.0100 2.78E+04 3.85E+08 Te127 4.13E+06 2.50E+03 2.06E-05 8.95E-04 3.18E+02 2.76E+10 0.0100 2.47E+05 3.08E+07 Te129m 2.31E+06 1.40E+03 2.39E-07 1.23E-02 2.40E+04 1.66E+10 0.0100 2.04E+06 1.40E+09 Te131m 8.75E+06 5.30E+03 6.42E-06 2.76E-01 6.50E+03 6.16E+10 0.0100 1.70E+08 1.40E+09 Te132 6.25E+07 3.79E+04 2.46E-06 3.81E-02 9.44E+03 4.46E+11 0.0100 1.70E+08 1.47E+10 Ba139 7.92E+07 4.80E+04 1.40E-04 8.03E-03 1.72E+02 3.59E+11 0.0100 2.88E+07 2.16E+08 Ba140 7.61E+07 4.61E+04 6.30E-07 3.17E-02 3.74E+03 5.47E+11 0.0100 1.73E+08 7.16E+09 Mo99 8.17E+07 4.95E+04 2.92E-06 2.69E-02 3.96E+03 5.82E+11 0.0100 1.57E+08 8.07E+09 Tc99m 7.19E+07 4.36E+04 3.20E-05 2.18E-02 3.26E+01 4.62E+11 0.0100 1.01E+08 5.28E+07 Ru103 7.29E+07 4.42E+04 2.04E-07 8.33E-02 8.96E+03 5.24E+11 0.0100 4.37E+08 1.64E+10 Ru105 5.18E+07 3.14E+04 4.34E-05 1.41E-01 4.55E+02 3.20E+11 0.0100 4.52E+08 5.10E+08 Ru106 2.85E+07 1.73E+04 2.18E-08 3.85E-02 4.77E+05 2.05E+11 0.0100 7.90E+07 3.43E+11 Rh105 4.83E+07 2.93E+04 5.45E-06 1.38E-02 9.55E+02 3.41E+11 0.0100 4.71E+07 1.14E+09 Y90 5.20E+06 3.15E+03 3.01E-06 7.03E-04 8.44E+03 3.70E+10 0.0100 2.60E+05 1.09E+09 Y91 5.24E+07 3.18E+04 1.37E-07 9.62E-04 4.88E+04 3.77E+11 0.0100 3.63E+06 6.44E+10 Y92 5.39E+07 3.27E+04 5.44E-05 4.81E-02 7.81E+02 3.21E+11 0.0100 1.54E+08 8.78E+08 Y93 6.17E+07 3.74E+04 1.91E-05 1.78E-02 2.15E+03 4.15E+11 0.0100 7.39E+07 3.12E+09 Zr95 7.35E+07 4.45E+04 1.25E-07 1.33E-01 2.36E+04 5.29E+11 0.0100 7.04E+08 4.37E+10 Zr97 7.36E+07 4.46E+04 1.14E-05 1.64E-01 4.33E+03 5.09E+11 0.0100 8.34E+08 7.71E+09 Nb95 7.48E+07 4.53E+04 2.28E-07 1.38E-01 5.81E+03 5.38E+11 0.0100 7.43E+08 1.09E+10 La140 8.01E+07 4.85E+04 4.78E-06 4.33E-01 4.85E+03 5.67E+11 0.0100 2.45E+09 9.62E+09 La141 7.13E+07 4.32E+04 4.90E-05 8.84E-03 5.81E+02 4.33E+11 0.0100 3.82E+07 8.80E+08 La142 6.87E+07 4.16E+04 1.25E-04 5.33E-01 2.53E+02 3.26E+11 0.0100 1.74E+09 2.89E+08 Pr143 6.60E+07 4.00E+04 5.92E-07 7.77E-05 8.10E+03 4.74E+11 0.0100 3.68E+05 1.34E+10 Nd147 2.83E+07 1.72E+04 7.31E-07 2.29E-02 6.85E+03 2.03E+11 0.0100 4.65E+07 4.87E+09 Am241 4.98E+03 3.02E+00 5.08E-11 3.03E-03 4.44E+08 3.59E+07 0.0100 1.09E+03 5.57E+10 Cm242 2.37E+06 1.44E+03 4.93E-08 2.11E-05 1.73E+07 1.71E+10 0.0100 3.60E+03 1.03E+12 Cm244 5.29E+05 3.21E+02 1.21E-09 1.82E-05 2.48E+08 3.81E+09 0.0100 6.93E+02 3.31E+12 Ce141 7.26E+07 4.40E+04 2.47E-07 1.27E-02 8.95E+03 5.22E+11 0.0100 6.63E+07 1.64E+10 Ce143 6.64E+07 4.02E+04 5.83E-06 4.77E-02 3.39E+03 4.68E+11 0.0100 2.23E+08 5.56E+09 Ce144 5.92E+07 3.59E+04 2.82E-08 1.03E-02 3.74E+05 4.26E+11 0.0100 4.39E+07 5.58E+11 Np239 8.95E+08 5.42E+05 3.41E-06 2.85E-02 2.51E+03 6.37E+12 0.0100 1.81E+09 5.59E+10 Pu238 2.10E+05 1.27E+02 2.50E-10 1.81E-05 2.88E+08 1.51E+09 0.0100 2.74E+02 1.52E+12 Pu239 1.24E+04 7.52E+00 9.13E-13 1.57E-05 3.08E+08 8.93E+07 0.0100 1.40E+01 9.62E+10
PSAT 3142CT.QA.04 Page 14 of 27 Rev. 0 1 2 3 4 Pu240 E
N 2.00E+04 1.21E+01 3.36E-12 1.76E-05 3.08E+08 1.44E+08 0.0100 2.53E+01 1.55E+11 Pu241 5.44E+06 3.30E+03 1.53E-09 2.68E-07 4.96E+06 3.92E+10 0.0100 1.05E+02 6.80E+11 Sr89 3.95E+07 2.39E+04 1.59E-07 2.86E-04 4.14E+04 2.84E+11 0.0100 8.13E+05 4.12E+10 Sr90 4.93E+06 2.99E+03 7.54E-10 2.79E-05 1.30E+06 3.55E+10 0.0100 9.90E+03 1.62E+11 Sr91 4.93E+07 2.99E+04 2.03E-05 1.82E-01 1.68E+03 3.30E+11 0.0100 6.01E+08 1.94E+09 Sr92 5.33E+07 3.23E+04 7.10E-05 2.51E-01 8.07E+02 3.00E+11 0.0100 WB 7.54E+08 8.49E+08
=
2.70E+11 D
9.58E+12 TE
=
9.85E+12 Ex G =
1.60E+11 NG + I =
1.57E+12
PSAT 3142CT.QA.04 Page 15 of 27 Rev. 0 1 2 3 4 Table 2 - OFA Thirty Day MWt =
1650 BR =
3.50E-04 m3/s Inhalation 30-day EE Inhalation Nuclide Activity Ci/MWt DK /sec EE DCF DCF Integral Rel fract Product Product I130 1.43E+06 8.67E+02 1.56E-05 3.85E-01 7.36E+04 9.17E+10 0.2500 8.82E+09 5.90E+11 I131 4.43E+07 2.68E+04 9.98E-07 6.73E-02 1.07E+06 4.10E+13 0.2500 6.91E+11 3.84E+15 I132 6.41E+07 3.88E+04 8.37E-05 4.14E-01 6.29E+03 7.66E+11 0.2500 7.93E+10 4.21E+11 I133 8.97E+07 5.44E+04 9.26E-06 1.09E-01 1.81E+05 9.69E+12 0.2500 2.64E+11 1.53E+14 I134 1.01E+08 6.12E+04 2.20E-04 4.81E-01 1.07E+03 4.59E+11 0.2500 5.52E+10 4.30E+10 I135 8.57E+07 5.19E+04 2.91E-05 3.07E-01 3.14E+04 2.95E+12 0.2500 2.26E+11 8.09E+12 Thyroid =
4.01E+15 MWt =
1650 BR =
3.50E-04 m3/s Inhalation 30-day EE Inhalation Nuclide Activity Ci/MWt DK /sec EE DCF DCF Integral Rel fract Product Product Kr85m 1.06E+07 6.42E+03 4.30E-05 2.77E-02 0
2.47E+11 1.0000 6.83E+09 0.00E+00 Kr85 6.23E+05 3.78E+02 2.05E-09 4.40E-04 0
1.61E+12 1.0000 7.09E+08 0.00E+00 Kr87 2.08E+07 1.26E+04 1.51E-04 1.52E-01 0
1.38E+11 1.0000 2.09E+10 0.00E+00 Kr88 2.77E+07 1.68E+04 6.78E-05 3.77E-01 0
4.09E+11 1.0000 1.54E+11 0.00E+00 Xe131m 4.97E+05 3.01E+02 6.74E-07 1.44E-03 0
6.09E+11 1.0000 8.77E+08 0.00E+00 Xe133m 2.81E+06 1.70E+03 3.67E-06 5.07E-03 0
7.66E+11 1.0000 3.88E+09 0.00E+00 Xe133 8.99E+07 5.45E+04 1.53E-06 5.77E-03 0
5.76E+13 1.0000 3.33E+11 0.00E+00 Xe135m 1.92E+07 1.16E+04 7.56E-04 7.55E-02 0
2.54E+10 1.0000 1.92E+09 0.00E+00 Xe135 1.82E+07 1.10E+04 2.12E-05 4.40E-02 0
8.58E+11 1.0000 3.78E+10 0.00E+00 Xe137 8.09E+07 4.90E+04 2.96E-03 3.03E-02 0
2.73E+10 1.0000 8.28E+08 0.00E+00 Xe138 7.59E+07 4.60E+04 6.80E-04 2.13E-01 0
1.12E+11 1.0000 2.38E+10 0.00E+00 I130 1.43E+06 8.67E+02 1.56E-05 3.85E-01 2.64E+03 9.17E+10 0.2500 8.82E+09 2.12E+10 I131 4.43E+07 2.68E+04 9.98E-07 6.73E-02 3.29E+04 4.10E+13 0.2500 6.91E+11 1.18E+14 I132 6.41E+07 3.88E+04 8.37E-05 4.14E-01 3.81E+02 7.66E+11 0.2500 7.93E+10 2.55E+10 I133 8.97E+07 5.44E+04 9.26E-06 1.09E-01 5.85E+03 9.69E+12 0.2500 2.64E+11 4.96E+12 I134 1.01E+08 6.12E+04 2.20E-04 4.81E-01 1.31E+02 4.59E+11 0.2500 5.52E+10 5.26E+09 I135 8.57E+07 5.19E+04 2.91E-05 3.07E-01 1.23E+03 2.95E+12 0.2500 2.26E+11 3.17E+11 Rb86 1.29E+05 7.82E+01 4.30E-07 1.78E-02 6.62E+03 2.02E+11 0.0100 3.59E+07 4.67E+09 Rb88 2.83E+07 1.72E+04 6.49E-04 1.24E-01 8.36E+01 4.36E+10 0.0100 5.41E+07 1.28E+07 Cs134 1.35E+07 8.18E+03 1.07E-08 2.80E-01 4.63E+04 3.45E+13 0.0100 9.66E+10 5.59E+12 Cs136 2.91E+06 1.76E+03 6.12E-07 3.92E-01 7.33E+03 3.78E+12 0.0100 1.48E+10 9.70E+10 Cs137 6.80E+06 4.12E+03 7.32E-10 1.01E-01 3.19E+04 1.76E+13 0.0100 1.78E+10 1.97E+12 Cs138 8.31E+07 5.04E+04 3.59E-04 4.48E-01 1.01E+02 2.31E+11 0.0100 1.04E+09 8.18E+07
PSAT 3142CT.QA.04 Page 16 of 27 Rev. 0 1 2 3 4 Sb127 4.19E+06 2.54E+03 2.08E-06 1.23E-01 6.03E+03 2.01E+12 0.0100 2.47E+09 4.23E+10 Sb129 1.28E+07 7.76E+03 4.46E-05 2.64E-01 6.44E+02 2.87E+11 0.0100 7.58E+08 6.47E+08 Te127m 7.11E+05 4.31E+02 7.36E-08 5.44E-04 2.15E+04 1.68E+12 0.0100 9.13E+06 1.26E+11 Te127 4.13E+06 2.50E+03 2.06E-05 8.95E-04 3.18E+02 2.00E+11 0.0100 1.79E+06 2.23E+08 Te129m 2.31E+06 1.40E+03 2.39E-07 1.23E-02 2.40E+04 4.46E+12 0.0100 5.49E+08 3.75E+11 Te131m 8.75E+06 5.30E+03 6.42E-06 2.76E-01 6.50E+03 1.36E+12 0.0100 3.76E+09 3.10E+10 Te132 6.25E+07 3.79E+04 2.46E-06 3.81E-02 9.44E+03 2.54E+13 0.0100 9.66E+09 8.38E+11 Ba139 7.92E+07 4.80E+04 1.40E-04 8.03E-03 1.72E+02 5.66E+11 0.0100 4.54E+07 3.41E+08 Ba140 7.61E+07 4.61E+04 6.30E-07 3.17E-02 3.74E+03 9.72E+13 0.0100 3.08E+10 1.27E+12 Mo99 8.17E+07 4.95E+04 2.92E-06 2.69E-02 3.96E+03 2.80E+13 0.0100 7.52E+09 3.88E+11 Tc99m 7.19E+07 4.36E+04 3.20E-05 2.18E-02 3.26E+01 2.25E+12 0.0100 4.90E+08 2.56E+08 Ru103 7.29E+07 4.42E+04 2.04E-07 8.33E-02 8.96E+03 1.47E+14 0.0100 1.22E+11 4.60E+12 Ru105 5.18E+07 3.14E+04 4.34E-05 1.41E-01 4.55E+02 1.19E+12 0.0100 1.68E+09 1.90E+09 Ru106 2.85E+07 1.73E+04 2.18E-08 3.85E-02 4.77E+05 7.18E+13 0.0100 2.77E+10 1.20E+14 Rh105 4.83E+07 2.93E+04 5.45E-06 1.38E-02 9.55E+02 8.86E+12 0.0100 1.22E+09 2.96E+10 Y90 5.20E+06 3.15E+03 3.01E-06 7.03E-04 8.44E+03 1.73E+12 0.0100 1.21E+07 5.10E+10 Y91 5.24E+07 3.18E+04 1.37E-07 9.62E-04 4.88E+04 1.14E+14 0.0100 1.10E+09 1.95E+13 Y92 5.39E+07 3.27E+04 5.44E-05 4.81E-02 7.81E+02 9.91E+11 0.0100 4.77E+08 2.71E+09 Y93 6.17E+07 3.74E+04 1.91E-05 1.78E-02 2.15E+03 3.23E+12 0.0100 5.75E+08 2.43E+10 Zr95 7.35E+07 4.45E+04 1.25E-07 1.33E-01 2.36E+04 1.63E+14 0.0100 2.16E+11 1.34E+13 Zr97 7.36E+07 4.46E+04 1.14E-05 1.64E-01 4.33E+03 6.46E+12 0.0100 1.06E+10 9.78E+10 Nb95 7.48E+07 4.53E+04 2.28E-07 1.38E-01 5.81E+03 1.46E+14 0.0100 2.02E+11 2.98E+12 La140 8.01E+07 4.85E+04 4.78E-06 4.33E-01 4.85E+03 1.68E+13 0.0100 7.26E+10 2.84E+11 La141 7.13E+07 4.32E+04 4.90E-05 8.84E-03 5.81E+02 1.46E+12 0.0100 1.29E+08 2.96E+09 La142 6.87E+07 4.16E+04 1.25E-04 5.33E-01 2.53E+02 5.50E+11 0.0100 2.93E+09 4.87E+08 Pr143 6.60E+07 4.00E+04 5.92E-07 7.77E-05 8.10E+03 8.75E+13 0.0100 6.80E+07 2.48E+12 Nd147 2.83E+07 1.72E+04 7.31E-07 2.29E-02 6.85E+03 3.29E+13 0.0100 7.53E+09 7.89E+11 Am241 4.98E+03 3.02E+00 5.08E-11 3.03E-03 4.44E+08 1.29E+10 0.0100 3.91E+05 2.01E+13 Cm242 2.37E+06 1.44E+03 4.93E-08 2.11E-05 1.73E+07 5.77E+12 0.0100 1.22E+06 3.49E+14 Cm244 5.29E+05 3.21E+02 1.21E-09 1.82E-05 2.48E+08 1.37E+12 0.0100 2.49E+05 1.19E+15 Ce141 7.26E+07 4.40E+04 2.47E-07 1.27E-02 8.95E+03 1.39E+14 0.0100 1.76E+10 4.35E+12 Ce143 6.64E+07 4.02E+04 5.83E-06 4.77E-02 3.39E+03 1.14E+13 0.0100 5.43E+09 1.35E+11 Ce144 5.92E+07 3.59E+04 2.82E-08 1.03E-02 3.74E+05 1.48E+14 0.0100 1.52E+10 1.94E+14 Np239 8.95E+08 5.42E+05 3.41E-06 2.85E-02 2.51E+03 2.62E+14 0.0100 7.48E+10 2.31E+12 Pu238 2.10E+05 1.27E+02 2.50E-10 1.81E-05 2.88E+08 5.44E+11 0.0100 9.85E+04 5.48E+14 Pu239 1.24E+04 7.52E+00 9.13E-13 1.57E-05 3.08E+08 3.21E+10 0.0100 5.05E+03 3.46E+13
PSAT 3142CT.QA.04 Page 17 of 27 Rev. 0 1 2 3 4 Pu240 E
N 2.00E+04 1.21E+01 3.36E-12 1.76E-05 3.08E+08 5.18E+10 0.0100 9.12E+03 5.59E+13 Pu241 5.44E+06 3.30E+03 1.53E-09 2.68E-07 4.96E+06 1.41E+13 0.0100 3.77E+04 2.44E+14 Sr89 3.95E+07 2.39E+04 1.59E-07 2.86E-04 4.14E+04 8.39E+13 0.0100 2.40E+08 1.22E+13 Sr90 4.93E+06 2.99E+03 7.54E-10 2.79E-05 1.30E+06 1.28E+13 0.0100 3.56E+06 5.81E+13 Sr91 4.93E+07 2.99E+04 2.03E-05 1.82E-01 1.68E+03 2.43E+12 0.0100 4.42E+09 1.43E+10 Sr92 5.33E+07 3.23E+04 7.10E-05 2.51E-01 8.07E+02 7.51E+11 0.0100 WB 1.88E+09 2.12E+09
=
2.88E+12 D
3.01E+15 TE
=
3.01E+15 Ex G =
2.30E+12
PSAT 3142CT.QA.04 Page 18 of 27 Rev. 0 1 2 3 4 Table 3 - HB Two Hour MWt =
1650 BR =
3.50E-04 m3/s Inhalation 2-hour EE Inhalation Nuclide Activity Ci/MWt DK /sec EE DCF DCF Integral Rel fract Product Product I130 1.39E+06 8.45E+02 1.56E-05 3.85E-01 7.36E+04 9.50E+09 0.2500 9.14E+08 6.11E+10 I131 4.33E+07 2.62E+04 9.98E-07 6.73E-02 1.07E+06 3.10E+11 0.2500 5.22E+09 2.91E+13 I132 6.26E+07 3.79E+04 8.37E-05 4.14E-01 6.29E+03 3.39E+11 0.2500 3.50E+10 1.86E+11 I133 8.78E+07 5.32E+04 9.26E-06 1.09E-01 1.81E+05 6.11E+11 0.2500 1.67E+10 9.68E+12 I134 9.81E+07 5.94E+04 2.20E-04 4.81E-01 1.07E+03 3.54E+11 0.2500 4.26E+10 3.32E+10 I135 8.38E+07 5.08E+04 2.91E-05 3.07E-01 3.14E+04 5.45E+11 0.2500 4.18E+10 1.50E+12 Thyroid =
4.05E+13 MWt =
1650 BR =
3.50E-04 m3/s Inhalation 2-hour EE Inhalation Nuclide Activity Ci/MWt DK /sec EE DCF DCF Integral Rel fract Product Product Kr85m 1.04E+07 6.29E+03 4.30E-05 2.77E-02 0
6.43E+10 1.0000 1.78E+09 0.00E+00 Kr85 6.88E+05 4.17E+02 2.05E-09 4.40E-04 0
4.95E+09 1.0000 2.18E+06 0.00E+00 Kr87 2.04E+07 1.24E+04 1.51E-04 1.52E-01 0
8.95E+10 1.0000 1.36E+10 0.00E+00 Kr88 2.71E+07 1.64E+04 6.78E-05 3.77E-01 0
1.54E+11 1.0000 5.82E+10 0.00E+00 Xe131m 4.87E+05 2.95E+02 6.74E-07 1.44E-03 0
3.49E+09 1.0000 5.03E+06 0.00E+00 Xe133m 2.75E+06 1.67E+03 3.67E-06 5.07E-03 0
1.95E+10 1.0000 9.91E+07 0.00E+00 Xe133 8.80E+07 5.33E+04 1.53E-06 5.77E-03 0
6.30E+11 1.0000 3.64E+09 0.00E+00 Xe135m 1.88E+07 1.14E+04 7.56E-04 7.55E-02 0
2.47E+10 1.0000 1.86E+09 0.00E+00 Xe135 1.99E+07 1.21E+04 2.12E-05 4.40E-02 0
1.33E+11 1.0000 5.85E+09 0.00E+00 Xe137 7.91E+07 4.79E+04 2.96E-03 3.03E-02 0
2.67E+10 1.0000 8.10E+08 0.00E+00 Xe138 7.42E+07 4.50E+04 6.80E-04 2.13E-01 0
1.08E+11 1.0000 2.31E+10 0.00E+00 I130 1.39E+06 8.45E+02 1.56E-05 3.85E-01 2.64E+03 9.50E+09 0.2500 9.14E+08 2.19E+09 I131 4.33E+07 2.62E+04 9.98E-07 6.73E-02 3.29E+04 3.10E+11 0.2500 5.22E+09 8.94E+11 I132 6.26E+07 3.79E+04 8.37E-05 4.14E-01 3.81E+02 3.39E+11 0.2500 3.50E+10 1.13E+10 I133 8.78E+07 5.32E+04 9.26E-06 1.09E-01 5.85E+03 6.11E+11 0.2500 1.67E+10 3.13E+11 I134 9.81E+07 5.94E+04 2.20E-04 4.81E-01 1.31E+02 3.54E+11 0.2500 4.26E+10 4.06E+09 I135 8.38E+07 5.08E+04 2.91E-05 3.07E-01 1.23E+03 5.45E+11 0.2500 4.18E+10 5.86E+10 Rb86 1.27E+05 7.70E+01 4.30E-07 1.78E-02 6.62E+03 9.13E+08 0.0100 1.63E+05 2.12E+07 Rb88 2.77E+07 1.68E+04 6.49E-04 1.24E-01 8.36E+01 4.23E+10 0.0100 5.24E+07 1.24E+07 Cs134 1.43E+07 8.68E+03 1.07E-08 2.80E-01 4.63E+04 1.03E+11 0.0100 2.89E+08 1.67E+10 Cs136 3.00E+06 1.82E+03 6.12E-07 3.92E-01 7.33E+03 2.16E+10 0.0100 8.45E+07 5.53E+08 Cs137 7.58E+06 4.59E+03 7.32E-10 1.01E-01 3.19E+04 5.46E+10 0.0100 5.51E+07 6.09E+09 Cs138 8.13E+07 4.93E+04 3.59E-04 4.48E-01 1.01E+02 2.09E+11 0.0100 9.38E+08 7.40E+07
PSAT 3142CT.QA.04 Page 19 of 27 Rev. 0 1 2 3 4 Sb127 Zr97 4.09E+06 2.48E+03 2.08E-06 1.23E-01 6.03E+03 2.92E+10 0.0100 3.60E+07 6.17E+08 Sb129 1.25E+07 7.58E+03 4.46E-05 2.64E-01 6.44E+02 7.70E+10 0.0100 2.03E+08 1.74E+08 Te127m 7.08E+05 4.29E+02 7.36E-08 5.44E-04 2.15E+04 5.09E+09 0.0100 2.77E+04 3.83E+08 Te127 4.05E+06 2.45E+03 2.06E-05 8.95E-04 3.18E+02 2.71E+10 0.0100 2.42E+05 3.01E+07 Te129m 2.26E+06 1.37E+03 2.39E-07 1.23E-02 2.40E+04 1.63E+10 0.0100 2.00E+06 1.37E+09 Te131m 8.56E+06 5.19E+03 6.42E-06 2.76E-01 6.50E+03 6.02E+10 0.0100 1.66E+08 1.37E+09 Te132 6.11E+07 3.70E+04 2.46E-06 3.81E-02 9.44E+03 4.36E+11 0.0100 1.66E+08 1.44E+10 Ba139 7.75E+07 4.70E+04 1.40E-04 8.03E-03 1.72E+02 3.52E+11 0.0100 2.82E+07 2.12E+08 Ba140 7.43E+07 4.50E+04 6.30E-07 3.17E-02 3.74E+03 5.34E+11 0.0100 1.69E+08 6.99E+09 Mo99 7.99E+07 4.84E+04 2.92E-06 2.69E-02 3.96E+03 5.69E+11 0.0100 1.53E+08 7.89E+09 Tc99m 7.03E+07 4.26E+04 3.20E-05 2.18E-02 3.26E+01 4.52E+11 0.0100 9.86E+07 5.16E+07 Ru103 7.12E+07 4.32E+04 2.04E-07 8.33E-02 8.96E+03 5.12E+11 0.0100 4.27E+08 1.61E+10 Ru105 5.05E+07 3.06E+04 4.34E-05 1.41E-01 4.55E+02 3.12E+11 0.0100 4.40E+08 4.97E+08 Ru106 2.96E+07 1.79E+04 2.18E-08 3.85E-02 4.77E+05 2.13E+11 0.0100 8.20E+07 3.56E+11 Rh105 4.75E+07 2.88E+04 5.45E-06 1.38E-02 9.55E+02 3.35E+11 0.0100 4.63E+07 1.12E+09 Y90 5.76E+06 3.49E+03 3.01E-06 7.03E-04 8.44E+03 4.10E+10 0.0100 2.88E+05 1.21E+09 Y91 5.13E+07 3.11E+04 1.37E-07 9.62E-04 4.88E+04 3.69E+11 0.0100 3.55E+06 6.31E+10 Y92 5.28E+07 3.20E+04 5.44E-05 4.81E-02 7.81E+02 3.15E+11 0.0100 1.51E+08 8.60E+08 Y93 6.04E+07 3.66E+04 1.91E-05 1.78E-02 2.15E+03 4.06E+11 0.0100 7.23E+07 3.06E+09 Zr95 7.22E+07 4.38E+04 1.25E-07 1.33E-01 2.36E+04 5.20E+11 0.0100 6.91E+08 4.29E+10 7.20E+07 4.36E+04 1.14E-05 1.64E-01 4.33E+03 4.98E+11 0.0100 8.16E+08 7.54E+09 Nb95 7.35E+07 4.45E+04 2.28E-07 1.38E-01 5.81E+03 5.29E+11 0.0100 7.30E+08 1.08E+10 La140 7.82E+07 4.74E+04 4.78E-06 4.33E-01 4.85E+03 5.53E+11 0.0100 2.40E+09 9.40E+09 La141 6.98E+07 4.23E+04 4.90E-05 8.84E-03 5.81E+02 4.23E+11 0.0100 3.74E+07 8.61E+08 La142 6.72E+07 4.07E+04 1.25E-04 5.33E-01 2.53E+02 3.19E+11 0.0100 1.70E+09 2.82E+08 Pr143 6.46E+07 3.92E+04 5.92E-07 7.77E-05 8.10E+03 4.64E+11 0.0100 3.61E+05 1.32E+10 Nd147 2.78E+07 1.68E+04 7.31E-07 2.29E-02 6.85E+03 2.00E+11 0.0100 4.57E+07 4.79E+09 Am241 6.29E+03 3.81E+00 5.08E-11 3.03E-03 4.44E+08 4.53E+07 0.0100 1.37E+03 7.04E+10 Cm242 2.68E+06 1.62E+03 4.93E-08 2.11E-05 1.73E+07 1.93E+10 0.0100 4.07E+03 1.17E+12 Cm244 5.89E+05 3.57E+02 1.21E-09 1.82E-05 2.48E+08 4.24E+09 0.0100 7.72E+02 3.68E+12 Ce141 7.11E+07 4.31E+04 2.47E-07 1.27E-02 8.95E+03 5.11E+11 0.0100 6.50E+07 1.60E+10 Ce143 6.50E+07 3.94E+04 5.83E-06 4.77E-02 3.39E+03 4.58E+11 0.0100 2.19E+08 5.44E+09 Ce144 6.01E+07 3.64E+04 2.82E-08 1.03E-02 3.74E+05 4.33E+11 0.0100 4.46E+07 5.66E+11 Np239 8.73E+08 5.29E+05 3.41E-06 2.85E-02 2.51E+03 6.21E+12 0.0100 1.77E+09 5.45E+10 Pu238 2.39E+05 1.45E+02 2.50E-10 1.81E-05 2.88E+08 1.72E+09 0.0100 3.11E+02 1.73E+12 Pu239 1.39E+04 8.42E+00 9.13E-13 1.57E-05 3.08E+08 1.00E+08 0.0100 1.57E+01 1.08E+11
PSAT 3142CT.QA.04 Page 20 of 27 Rev. 0 1 2 3 4 Pu240 E
N 2.24E+04 1.36E+01 3.36E-12 1.76E-05 3.08E+08 1.61E+08 0.0100 2.84E+01 1.74E+11 Pu241 6.07E+06 3.68E+03 1.53E-09 2.68E-07 4.96E+06 4.37E+10 0.0100 1.17E+02 7.59E+11 Sr89 3.83E+07 2.32E+04 1.59E-07 2.86E-04 4.14E+04 2.76E+11 0.0100 7.88E+05 3.99E+10 Sr90 5.49E+06 3.33E+03 7.54E-10 2.79E-05 1.30E+06 3.95E+10 0.0100 1.10E+04 1.80E+11 Sr91 4.82E+07 2.92E+04 2.03E-05 1.82E-01 1.68E+03 3.23E+11 0.0100 5.88E+08 1.90E+09 Sr92 5.22E+07 3.16E+04 7.10E-05 2.51E-01 8.07E+02 2.94E+11 0.0100 WB 7.39E+08 8.31E+08
=
2.65E+11 D
1.04E+13 TE
=
1.07E+13 Ex G =
1.56E+11 NG + I =
1.53E+12
PSAT 3142CT.QA.04 Page 21 of 27 Rev. 0 1 2 3 4 Table 4 - HB Thirty Day MWt =
1650 BR =
3.50E-04 m3/s Inhalation 30-day EE Inhalation Nuclide Activity Ci/MWt DK /sec EE DCF DCF Integral Rel fract Product Product I130 1.39E+06 8.45E+02 1.56E-05 3.85E-01 7.36E+04 8.94E+10 0.2500 8.60E+09 5.76E+11 I131 4.33E+07 2.62E+04 9.98E-07 6.73E-02 1.07E+06 4.01E+13 0.2500 6.75E+11 3.75E+15 I132 6.26E+07 3.79E+04 8.37E-05 4.14E-01 6.29E+03 7.48E+11 0.2500 7.74E+10 4.12E+11 I133 8.78E+07 5.32E+04 9.26E-06 1.09E-01 1.81E+05 9.48E+12 0.2500 2.58E+11 1.50E+14 I134 9.81E+07 5.94E+04 2.20E-04 4.81E-01 1.07E+03 4.46E+11 0.2500 5.36E+10 4.17E+10 I135 8.38E+07 5.08E+04 2.91E-05 3.07E-01 3.14E+04 2.88E+12 0.2500 2.21E+11 7.92E+12 Thyroid =
3.91E+15 MWt =
1650 BR =
3.50E-04 m3/s Inhalation 30-day EE Inhalation Nuclide Activity Ci/MWt DK /sec EE DCF DCF Integral Rel fract Product Product Kr85m 1.04E+07 6.29E+03 4.30E-05 2.77E-02 0
2.42E+11 1.0000 6.69E+09 0.00E+00 Kr85 6.88E+05 4.17E+02 2.05E-09 4.40E-04 0
1.78E+12 1.0000 7.82E+08 0.00E+00 Kr87 2.04E+07 1.24E+04 1.51E-04 1.52E-01 0
1.35E+11 1.0000 2.05E+10 0.00E+00 Kr88 2.71E+07 1.64E+04 6.78E-05 3.77E-01 0
4.00E+11 1.0000 1.51E+11 0.00E+00 Xe131m 4.87E+05 2.95E+02 6.74E-07 1.44E-03 0
5.96E+11 1.0000 8.58E+08 0.00E+00 Xe133m 2.75E+06 1.67E+03 3.67E-06 5.07E-03 0
7.49E+11 1.0000 3.80E+09 0.00E+00 Xe133 8.80E+07 5.33E+04 1.53E-06 5.77E-03 0
5.64E+13 1.0000 3.26E+11 0.00E+00 Xe135m 1.88E+07 1.14E+04 7.56E-04 7.55E-02 0
2.48E+10 1.0000 1.87E+09 0.00E+00 Xe135 1.99E+07 1.21E+04 2.12E-05 4.40E-02 0
9.39E+11 1.0000 4.13E+10 0.00E+00 Xe137 7.91E+07 4.79E+04 2.96E-03 3.03E-02 0
2.67E+10 1.0000 8.10E+08 0.00E+00 Xe138 7.42E+07 4.50E+04 6.80E-04 2.13E-01 0
1.09E+11 1.0000 2.33E+10 0.00E+00 I130 1.39E+06 8.45E+02 1.56E-05 3.85E-01 2.64E+03 8.94E+10 0.2500 8.60E+09 2.06E+10 I131 4.33E+07 2.62E+04 9.98E-07 6.73E-02 3.29E+04 4.01E+13 0.2500 6.75E+11 1.15E+14 I132 6.26E+07 3.79E+04 8.37E-05 4.14E-01 3.81E+02 7.48E+11 0.2500 7.74E+10 2.49E+10 I133 8.78E+07 5.32E+04 9.26E-06 1.09E-01 5.85E+03 9.48E+12 0.2500 2.58E+11 4.85E+12 I134 9.81E+07 5.94E+04 2.20E-04 4.81E-01 1.31E+02 4.46E+11 0.2500 5.36E+10 5.11E+09 I135 8.38E+07 5.08E+04 2.91E-05 3.07E-01 1.23E+03 2.88E+12 0.2500 2.21E+11 3.10E+11 Rb86 1.27E+05 7.70E+01 4.30E-07 1.78E-02 6.62E+03 1.98E+11 0.0100 3.53E+07 4.60E+09 Rb88 2.77E+07 1.68E+04 6.49E-04 1.24E-01 8.36E+01 4.27E+10 0.0100 5.29E+07 1.25E+07 Cs134 1.43E+07 8.68E+03 1.07E-08 2.80E-01 4.63E+04 3.66E+13 0.0100 1.03E+11 5.94E+12 Cs136 3.00E+06 1.82E+03 6.12E-07 3.92E-01 7.33E+03 3.90E+12 0.0100 1.53E+10 1.00E+11 Cs137 7.58E+06 4.59E+03 7.32E-10 1.01E-01 3.19E+04 1.96E+13 0.0100 1.98E+10 2.19E+12 Cs138 8.13E+07 4.93E+04 3.59E-04 4.48E-01 1.01E+02 2.26E+11 0.0100 1.01E+09 8.01E+07
PSAT 3142CT.QA.04 Page 22 of 27 Rev. 0 1 2 3 4 Sb127 4.09E+06 2.48E+03 2.08E-06 1.23E-01 6.03E+03 1.96E+12 0.0100 2.41E+09 4.13E+10 Sb129 1.25E+07 7.58E+03 4.46E-05 2.64E-01 6.44E+02 2.80E+11 0.0100 7.40E+08 6.32E+08 Te127m 7.08E+05 4.29E+02 7.36E-08 5.44E-04 2.15E+04 1.67E+12 0.0100 9.08E+06 1.26E+11 Te127 4.05E+06 2.45E+03 2.06E-05 8.95E-04 3.18E+02 1.97E+11 0.0100 1.76E+06 2.19E+08 Te129m 2.26E+06 1.37E+03 2.39E-07 1.23E-02 2.40E+04 4.37E+12 0.0100 5.37E+08 3.67E+11 Te131m 8.56E+06 5.19E+03 6.42E-06 2.76E-01 6.50E+03 1.33E+12 0.0100 3.68E+09 3.03E+10 Te132 6.11E+07 3.70E+04 2.46E-06 3.81E-02 9.44E+03 2.48E+13 0.0100 9.44E+09 8.19E+11 Ba139 7.75E+07 4.70E+04 1.40E-04 8.03E-03 1.72E+02 5.54E+11 0.0100 4.45E+07 3.33E+08 Ba140 7.43E+07 4.50E+04 6.30E-07 3.17E-02 3.74E+03 9.49E+13 0.0100 3.01E+10 1.24E+12 Mo99 7.99E+07 4.84E+04 2.92E-06 2.69E-02 3.96E+03 2.73E+13 0.0100 7.36E+09 3.79E+11 Tc99m 7.03E+07 4.26E+04 3.20E-05 2.18E-02 3.26E+01 2.20E+12 0.0100 4.79E+08 2.51E+08 Ru103 7.12E+07 4.32E+04 2.04E-07 8.33E-02 8.96E+03 1.43E+14 0.0100 1.19E+11 4.49E+12 Ru105 5.05E+07 3.06E+04 4.34E-05 1.41E-01 4.55E+02 1.16E+12 0.0100 1.64E+09 1.85E+09 Ru106 2.96E+07 1.79E+04 2.18E-08 3.85E-02 4.77E+05 7.46E+13 0.0100 2.87E+10 1.25E+14 Rh105 4.75E+07 2.88E+04 5.45E-06 1.38E-02 9.55E+02 8.72E+12 0.0100 1.20E+09 2.91E+10 Y90 5.76E+06 3.49E+03 3.01E-06 7.03E-04 8.44E+03 1.91E+12 0.0100 1.34E+07 5.65E+10 Y91 5.13E+07 3.11E+04 1.37E-07 9.62E-04 4.88E+04 1.12E+14 0.0100 1.08E+09 1.91E+13 Y92 5.28E+07 3.20E+04 5.44E-05 4.81E-02 7.81E+02 9.71E+11 0.0100 4.67E+08 2.65E+09 Y93 6.04E+07 3.66E+04 1.91E-05 1.78E-02 2.15E+03 3.16E+12 0.0100 5.63E+08 2.38E+10 Zr95 7.22E+07 4.38E+04 1.25E-07 1.33E-01 2.36E+04 1.60E+14 0.0100 2.13E+11 1.32E+13 Zr97 7.20E+07 4.36E+04 1.14E-05 1.64E-01 4.33E+03 6.32E+12 0.0100 1.04E+10 9.57E+10 Nb95 7.35E+07 4.45E+04 2.28E-07 1.38E-01 5.81E+03 1.44E+14 0.0100 1.99E+11 2.93E+12 La140 7.82E+07 4.74E+04 4.78E-06 4.33E-01 4.85E+03 1.64E+13 0.0100 7.08E+10 2.78E+11 La141 6.98E+07 4.23E+04 4.90E-05 8.84E-03 5.81E+02 1.42E+12 0.0100 1.26E+08 2.90E+09 La142 6.72E+07 4.07E+04 1.25E-04 5.33E-01 2.53E+02 5.38E+11 0.0100 2.87E+09 4.76E+08 Pr143 6.46E+07 3.92E+04 5.92E-07 7.77E-05 8.10E+03 8.56E+13 0.0100 6.65E+07 2.43E+12 Nd147 2.78E+07 1.68E+04 7.31E-07 2.29E-02 6.85E+03 3.23E+13 0.0100 7.40E+09 7.75E+11 Am241 6.29E+03 3.81E+00 5.08E-11 3.03E-03 4.44E+08 1.63E+10 0.0100 4.94E+05 2.53E+13 Cm242 2.68E+06 1.62E+03 4.93E-08 2.11E-05 1.73E+07 6.52E+12 0.0100 1.38E+06 3.95E+14 Cm244 5.89E+05 3.57E+02 1.21E-09 1.82E-05 2.48E+08 1.52E+12 0.0100 2.77E+05 1.32E+15 Ce141 7.11E+07 4.31E+04 2.47E-07 1.27E-02 8.95E+03 1.36E+14 0.0100 1.73E+10 4.26E+12 Ce143 6.50E+07 3.94E+04 5.83E-06 4.77E-02 3.39E+03 1.11E+13 0.0100 5.32E+09 1.32E+11 Ce144 6.01E+07 3.64E+04 2.82E-08 1.03E-02 3.74E+05 1.50E+14 0.0100 1.55E+10 1.97E+14 Np239 8.73E+08 5.29E+05 3.41E-06 2.85E-02 2.51E+03 2.56E+14 0.0100 7.30E+10 2.25E+12 Pu238 2.39E+05 1.45E+02 2.50E-10 1.81E-05 2.88E+08 6.19E+11 0.0100 1.12E+05 6.24E+14 Pu239 1.39E+04 8.42E+00 9.13E-13 1.57E-05 3.08E+08 3.60E+10 0.0100 5.66E+03 3.88E+13
PSAT 3142CT.QA.04 Page 23 of 27 Rev. 0 1 2 3 4 Pu240 E
N 2.24E+04 1.36E+01 3.36E-12 1.76E-05 3.08E+08 5.81E+10 0.0100 1.02E+04 6.26E+13 Pu241 6.07E+06 3.68E+03 1.53E-09 2.68E-07 4.96E+06 1.57E+13 0.0100 4.21E+04 2.73E+14 Sr89 3.83E+07 2.32E+04 1.59E-07 2.86E-04 4.14E+04 8.14E+13 0.0100 2.33E+08 1.18E+13 Sr90 5.49E+06 3.33E+03 7.54E-10 2.79E-05 1.30E+06 1.42E+13 0.0100 3.97E+06 6.47E+13 Sr91 4.82E+07 2.92E+04 2.03E-05 1.82E-01 1.68E+03 2.37E+12 0.0100 4.32E+09 1.40E+10 Sr92 5.22E+07 3.16E+04 7.10E-05 2.51E-01 8.07E+02 7.35E+11 0.0100 WB 1.85E+09 2.08E+09
=
2.84E+12 D
3.32E+15 TE
=
3.32E+15 Ex G =
2.26E+12
PSAT 3 142CT.QA.04 Page 24 of 27
~ e v. i l 2 3 4 Preparation of the SITARDOSE plant model STARDOSE is used to confirm the results summarized in Table 5. The plant model is presented below.
Arrangement Activity ReleasesJi.sm the Coolant and Core The junctions from the Core control volume to the primary containment (PC) control volume and the Sump (explained below) allow the activity to be added according to hourly rates. The hourly rates are equal to the RG 1.4 release fractions (1 00% of the noble gas, 25% of the iodine, and 1%
of the remaining activity) divided by 0.00056 hours (two seconds to simulate an instantaneous release).
The release tables used in STARDOSE reflecting the above modeling are as follows (the values are fractions per hour for the end times given in hours):
Release to PC Time N-Gas I-Grp CsGrp TeGrp BaGrp NMtls CeGrp LaGrp SrGrp 0.00056 1786 446 17.9 17.9 17.9 17.9 17.9 17.9 17.9 720 0
0 0
0 0
0 0
0 0
Release to Sump Time N-Gas I-Grp CsGrp TeGrp BaGrp NMtls CeGrp LaGrp SrGrp 0.00056 0
446 0
0 0
0 0
0 0
720 0
0 0
0 0
0 0
0 0
Note that the release to the sump is included. If Engineered Safety Feature (ESF) leakage outside containment were to be considered (not currently part of the model) the organic and particulate fractions; would be filtered completely and the elemental iodine would be filtered
PSAT 3 142CT.QA.04 Page 25 of 27
~ e v. [ 1 2 3 4 assuming an efficiency of 89%. This assumption would be equivalent to a 10% release of the iodine in the sump water but all as elemental. Note that in order to model a 50% release of iodine to the sump water (a typical assumption for ESF leakage modeling), the I-Grp release rate to the sump would have to be increased by a factor of two to 892 per hour.
Activity Removal Rates In the PC, elemental iodine is removed at a rate of 20 per hour and the particulate is removed at a rate of 0.45 per hour. 'Those rates are applied from t = 1 minute to t = 14.8 minutes when a DF of 100 is reached for the elemental iodine.
Filtration of Activity in Release Pathways The following is the equivalent filtration of releases via the Auxiliary Building (0.1 % per day of the containment vollume through the building filters and 0.01% per day bypassing the building filters, both leak rates reduced by a factor of two at t = 24 hours2.777778e-4 days <br />0.00667 hours <br />3.968254e-5 weeks <br />9.132e-6 months <br />).
0.14% per day of the containment volume is leaked to the Shield Building (reduced by a factor two at t = 24 hours2.777778e-4 days <br />0.00667 hours <br />3.968254e-5 weeks <br />9.132e-6 months <br />). The filter efficiency for the Shield Building exhaust path and for the Shield Building recirculation path is 90% for elemental iodine, 70% for organic iodine, and 99% for particulate. The tirne-dependent flows are as follows:
PSAT 3142CT.QA.04 Page 26 of 27 Rev. 0 1 2 3 4 STARDOSE Library File The LIBFILE1.TXT file used in the analysis is presented in Appendix Aa for the OFA fuel and Appendix Ab for the HB fuel.
Performance of STARDOSE Runs.
The INPUT.DAT file is presented in Appendix B. Excerpts of the output files for both the OFA fuel case and the HB fuel case are presented in Appendix C.
Performance of MicroShield Runs.
The use of STARGATE [8] to extract t = 0 waterborne (i.e., non-NG) source activities from the STARDOSE RESULTS.OUT files and the use of those activities in MicroShield [9] to obtain long-term dose rates is described in Appendix D.
Results Table 5 - Results Summary - Dose Index Thyroid Index WB Index WB w/o NG TEDE Index NG + I TEDE OFA Two-Hour EAB 4.15E+13 2.70E+11 1.60E+11 9.85E+12 1.57E+12 OFA Thirty-Day LPZ 4.01E+15 2.88E+12 2.30E+12 3.01E+15 N/A HB Two-Hour EAB 4.05E+13 2.65E+11 1.56E+11 1.07E+13 1.53E+12 HB Thirty-Day LPZ 3.91E+15 2.84E+12 2.26E+12 3.32E+15 N/A OFA/HB Two Hour 1.025 1.019 1.026 0.921 1.026 OFA/HB Thirty Day 1.026 1.014 1.018 0.901 N/A Table 6 - Results Summary - STARDOSE (Doses in Rem)
Thyroid Dose WB Dose TEDE Dose OFA Two-Hour EAB 1.06E+001 1.26E+000 8.00E+000 OFA Thirty-Day LPZ 2.43E+000 1.88E-001 2.23E+000 HB Two-Hour EAB 1.04E+001 1.24E+000 8.66E+000 HB Thirty-Day LPZ 2.37E+000 1.86E-001 2.44E+000 OFA/HB Two Hour 1.019 1.016 0.924 OFA/HB Thirty Day 1.025 1.011 0.914
PSAT 3142CT.QA.04 Page 27 of 27 Rev. 0 1 2 3 4 Table 7 - Comparison of Activity (Ci) Released to Environment -
STARDOSE OFA Fuel Case vs. Item 2.1 (Attachment 3) of Reference [7]
Core (OFA)
Core (Item 2.1) 2-Hour (OFA) 2-Hour (Item 2.1) 30-Day (OFA) 30-Day (Item 2.1)
Kr85m 1.06E+07 1.1E+07 1.11E+03 1.15E+03 5.75E+03 5.86E+03 Kr85 6.23E+05 6.9E+05 7.64E+01 8.62E+01 2.35E+04 2.61E+04 Kr87 2.08E+07 2.1E+07 1.50E+03 1.51E+03 2.59E+03 2.61E+03 Kr88 2.77E+07 2.9E+07 2.64E+03 2.76E+03 8.94E+03 9.22E+03 Xe131m 4.97E+05 3.2E+05 6.08E+01 3.92E+01 9.22E+03 5.92E+03 Xe133m 2.81E+06 1.3E+07 3.40E+02 1.57E+03 1.37E+04 6.52E+04 Xe133 8.99E+07 9.2E+07 1.10E+04 1.12E+04 9.21E+05 9.48E+05 Xe135m 1.92E+07 1.9E+07 3.75E+02 3.80E+02 3.77E+02 3.82E+02 Xe135 1.82E+07 1.9E+07 2.07E+03 2.15E+03 2.06E+04 2.14E+04 Xe137 8.09E+07 8.1E+07 3.83E+02 3.78E+02 3.83E+02 3.78E+02 Xe138 7.59E+07 7.3E+07 1.65E+03 1.65E+03 1.67E+03 1.67E+03 I131 4.43E+07 4.6E+07 3.13E+01 3.26E+01 1.78E+03 1.84E+03 I132 6.41E+07 6.6E+07 3.85E+01 3.72E+01 4.23E+02 7.06E+01 I133 8.97E+07 9.2E+07 6.19E+01 6.35E+01 6.11E+02 6.16E+02 I134 1.01E+08 9.9E+07 4.26E+01 4.16E+01 5.00E+01 4.88E+01 I135 8.57E+07 8.5E+07 5.60E+01 5.56E+01 2.37E+02 2.37E+02 With the exception of I-132 30-day releases, the agreement is good in light of differences in core inventory for Xe-131m and Xe-133m. The problem with I-132 at 30 days may be that STARDOSE has daughter in growth from Te-132 that may not have been included in the methodology of Item 2.1 of reference [7].
Conclusions Both the dose index spreadsheet and the confirming STARDOSE run produce essentially the same results. The OFA fuel produces higher thyroid and whole body doses than the HB fuel over the 30-day dose interval for the MHA dose calculation, although while the OFA fuel thyroid dose margin is increasing with time, the whole body dose margin is decreasing, both with and without noble gases included. This decreasing whole body dose margin for the OFA fuel suggests that for EQ purposes, the potential exists for the HB fuel external exposure dose rates to eventually exceed those for the OFA fuel. This potential has been confirmed by the MicroShield analysis presented in Appendix D. However, the external exposure dose rate becomes only marginally higher for the HB fuel than for the OFA fuel (see Appendix D); and given the margin that exists in the whole body dose at 30 days, it is unlikely that the external exposure (i.e., EQ) doses would become greater for the HB fuel than for the OFA fuel beyond 30 days.
The TEDE dose indices for the two cases indicate that HB fuel may be limiting for situations in which TEDE must be reported except for Fuel Handling Accident (FHA) which is dominated by noble gas and iodine. TEDE is not reported for dose analyses performed in accordance with reference [1]; and, except for FHA, this observation is made here for information only.
PSAT 3142CT.QA.04 Appendix Aa Page Aa1 of Aa2 Rev. 0 1 2 3 4 LIBFILE1.TXT - OFA n_isotopes 77 n_isotope_groups 11 Kr85m N_Gas NONE NONE 1.06E+07 4.30E-05 0 2.77E-02 0 0
0 0
0 0
0 0
0 0
Kr85 N_Gas NONE NONE 6.23E+05 2.05E-09 0 4.40E-04 0 0
0 0
0 0
0 0
0 0
Kr87 N_Gas NONE NONE 2.08E+07 1.51E-04 0 1.52E-01 0 0
0 0
0 0
0 0
0 0
Kr88 N_Gas NONE Rb88 2.77E+07 6.78E-05 0 3.77E-01 0 0
0 0
0 0
0 0
0 0
Xe131m N_Gas NONE NONE 4.97E+05 6.74E-07 0 1.44E-03 0 0
0 0
0 0
0 0
0 0
Xe133m N_Gas NONE NONE 2.81E+06 3.67E-06 0 5.07E-03 0 0
0 0
0 0
0 0
0 0
Xe133 N_Gas I133Elem NONE 8.99E+07 1.53E-06 0 5.77E-03 0 0
0 0
0 0
0 0
0 0
Xe135m N_Gas NONE NONE 1.92E+07 7.56E-04 0 7.55E-02 0 0
0 0
0 0
0 0
0 0
Xe135 N_Gas I135Elem NONE 1.82E+07 2.12E-05 0 4.40E-02 0 0
0 0
0 0
0 0
0 0
Xe137 N_Gas NONE Cs137 8.09E+07 2.96E-03 0 3.03E-02 0 0
0 0
0 0
0 0
0 0
Xe138 N_Gas NONE Cs138 7.59E+07 6.80E-04 0 2.13E-01 0 0
0 0
0 0
0 0
0 0
I130Org Org_I NONE NONE 1.43E+06 1.56E-05 7.36E+04 3.85E-01 0 0
0 2.64E+03 0 0
0 0
0 0
I131Org Org_I NONE NONE 4.43E+07 9.98E-07 1.07E+06 6.73E-02 0 0
0 3.29E+04 0 0
0 0
0 0
I132Org Org_I NONE NONE 6.41E+07 8.37E-05 6.29E+03 4.14E-01 0 0
0 3.81E+02 0 0
0 0
0 0
I133Org Org_I NONE NONE 8.97E+07 9.26E-06 1.81E+05 1.09E-01 0 0
0 5.85E+03 0 0
0 0
0 0
I134Org Org_I NONE NONE 1.01E+08 2.20E-04 1.07E+03 4.81E-01 0 0
0 1.31E+02 0 0
0 0
0 0
I135Org Org_I NONE NONE 8.57E+07 2.91E-05 3.14E+04 3.07E-01 0 0
0 1.23E+03 0 0
0 0
0 0
I130Elem Elm_I NONE NONE 1.43E+06 1.56E-05 7.36E+04 3.85E-01 0 0
0 2.64E+03 0 0
0 0
0 0
I131Elem Elm_I Te131m NONE 4.43E+07 9.98E-07 1.07E+06 6.73E-02 0 0
0 3.29E+04 0 0
0 0
0 0
I132Elem Elm_I Te132 NONE 6.41E+07 8.37E-05 6.29E+03 4.14E-01 0 0
0 3.81E+02 0 0
0 0
0 0
I133Elem Elm_I NONE Xe133 8.97E+07 9.26E-06 1.81E+05 1.09E-01 0 0
0 5.85E+03 0 0
0 0
0 0
I134Elem Elm_I NONE NONE 1.01E+08 2.20E-04 1.07E+03 4.81E-01 0 0
0 1.31E+02 0 0
0 0
0 0
I135Elem Elm_I NONE Xe135 8.57E+07 2.91E-05 3.14E+04 3.07E-01 0 0
0 1.23E+03 0 0
0 0
0 0
I130Part Prt_I NONE NONE 1.43E+06 1.56E-05 7.36E+04 3.85E-01 0 0
0 2.64E+03 0 0
0 0
0 0
I131Part Prt_I NONE NONE 4.43E+07 9.98E-07 1.07E+06 6.73E-02 0 0
0 3.29E+04 0 0
0 0
0 0
I132Part Prt_I NONE NONE 6.41E+07 8.37E-05 6.29E+03 4.14E-01 0 0
0 3.81E+02 0 0
0 0
0 0
I133Part Prt_I NONE NONE 8.97E+07 9.26E-06 1.81E+05 1.09E-01 0 0
0 5.85E+03 0 0
0 0
0 0
I134Part Prt_I NONE NONE 1.01E+08 2.20E-04 1.07E+03 4.81E-01 0 0
0 1.31E+02 0 0
0 0
0 0
I135Part Prt_I NONE NONE 8.57E+07 2.91E-05 3.14E+04 3.07E-01 0 0
0 1.23E+03 0 0
0 0
0 0
Rb86 CsGrp NONE NONE 1.29E+05 4.30E-07 0 1.78E-02 0 0
0 6.62E+03 0 0
0 0
0 0
Rb88 CsGrp Kr88 NONE 2.83E+07 6.49E-04 0 1.24E-01 0 0
0 8.36E+01 0 0
0 0
0 0
Cs134 CsGrp NONE NONE 1.33E+07 1.07E-08 0 2.80E-01 0 0
0 4.63E+04 0 0
0 0
0 0
Cs136 CsGrp NONE NONE 2.91E+06 6.12E-07 0 3.92E-01 0 0
0 7.33E+03 0 0
0 0
0 0
Cs137 CsGrp Xe137 NONE 6.80E+06 7.32E-10 0 1.01E-01 0 0
0 3.19E+04 0 0
0 0
0 0
Cs138 CsGrp Xe138 NONE 8.31E+07 3.59E-04 0 4.48E-01 0 0
0 1.01E+02 0 0
0 0
0 0
Sb127 TeGrp NONE Te127 4.19E+06 2.08E-06 0 1.23E-01 0 0
0 6.03E+03 0 0
0 0
0 0
Sb129 TeGrp NONE NONE 1.28E+07 4.46E-05 0 2.64E-01 0 0
0 6.44E+02 0 0
0 0
0 0
PSAT 3142CT.QA.04 Appendix Aa Page Aa2 of Aa2 Rev. 0 1 2 3 4 Te127m TeGrp NONE NONE 7.11E+05 7.36E-08 0 5.44E-04 0 0
0 2.15E+04 0 0
0 0
0 0
Te127 TeGrp Sb127 NONE 4.13E+06 2.06E-05 0 8.95E-04 0 0
0 3.18E+02 0 0
0 0
0 0
Te129m TeGrp NONE NONE 2.31E+06 2.39E-07 0 1.23E-02 0 0
0 2.40E+04 0 0
0 0
0 0
Te131m TeGrp NONE I131Elem 8.75E+06 6.42E-06 0 2.76E-01 0 0
0 6.50E+03 0 0
0 0
0 0
Te132 TeGrp NONE I132Elem 6.25E+07 2.46E-06 0 3.81E-02 0 0
0 9.44E+03 0 0
0 0
0 0
Ba139 BaGrp NONE NONE 7.92E+07 1.40E-04 0 8.03E-03 0 0
0 1.72E+02 0 0
0 0
0 0
Ba140 BaGrp NONE La140 7.61E+07 6.30E-07 0 3.17E-02 0 0
0 3.74E+03 0 0
0 0
0 0
Mo99 NMtls NONE Tc99m 8.17E+07 2.92E-06 0 2.69E-02 0 0
0 3.96E+03 0 0
0 0
0 0
Tc99m NMtls Mo99 NONE 7.19E+07 3.20E-05 0 2.18E-02 0 0
0 3.26E+01 0 0
0 0
0 0
Ru103 NMtls NONE NONE 7.29E+07 2.04E-07 0 8.33E-02 0 0
0 8.96E+03 0 0
0 0
0 0
Ru105 NMtls NONE Rh105 5.18E+07 4.34E-05 0 1.41E-01 0 0
0 4.55E+02 0 0
0 0
0 0
Ru106 NMtls NONE NONE 2.85E+07 2.18E-08 0 3.85E-02 0 0
0 4.77E+05 0 0
0 0
0 0
Rh105 NMtls Ru105 NONE 4.83E+07 5.45E-06 0 1.38E-02 0 0
0 9.55E+02 0 0
0 0
0 0
Y90 LaGrp Sr90 NONE 5.20E+06 3.01E-06 0 7.03E-04 0 0
0 8.44E+03 0 0
0 0
0 0
Y91 LaGrp Sr91 NONE 5.24E+07 1.37E-07 0 9.62E-04 0 0
0 4.88E+04 0 0
0 0
0 0
Y92 LaGrp Sr92 NONE 5.39E+07 5.44E-05 0 4.81E-02 0 0
0 7.81E+02 0 0
0 0
0 0
Y93 LaGrp NONE NONE 6.17E+07 1.91E-05 0 1.78E-02 0 0
0 2.15E+03 0 0
0 0
0 0
Zr95 LaGrp NONE Nb95 7.35E+07 1.25E-07 0 1.33E-01 0 0
0 2.36E+04 0 0
0 0
0 0
Zr97 LaGrp NONE NONE 7.36E+07 1.14E-05 0 1.64E-01 0 0
0 4.33E+03 0 0
0 0
0 0
Nb95 LaGrp Zr95 NONE 7.48E+07 2.28E-07 0 1.38E-01 0 0
0 5.81E+03 0 0
0 0
0 0
La140 LaGrp Ba140 NONE 8.01E+07 4.78E-06 0 4.33E-01 0 0
0 4.85E+03 0 0
0 0
0 0
La141 LaGrp NONE Ce141 7.13E+07 4.90E-05 0 8.84E-03 0 0
0 5.81E+02 0 0
0 0
0 0
La142 LaGrp NONE NONE 6.87E+07 1.25E-04 0 5.33E-01 0 0
0 2.53E+02 0 0
0 0
0 0
Pr143 LaGrp Ce143 NONE 6.60E+07 5.92E-07 0 7.77E-05 0 0
0 8.10E+03 0 0
0 0
0 0
Nd147 LaGrp NONE NONE 2.83E+07 7.31E-07 0 2.29E-02 0 0
0 6.85E+03 0 0
0 0
0 0
Am241 LaGrp NONE NONE 4.98E+03 5.08E-11 0 3.03E-03 0 0
0 4.44E+08 0 0
0 0
0 0
Cm242 LaGrp NONE NONE 2.37E+06 4.93E-08 0 2.11E-05 0 0
0 1.73E+07 0 0
0 0
0 0
Cm244 LaGrp NONE NONE 5.29E+05 1.21E-09 0 1.82E-05 0 0
0 2.48E+08 0 0
0 0
0 0
Ce141 CeGrp La141 NONE 7.26E+07 2.47E-07 0 1.27E-02 0 0
0 8.95E+03 0 0
0 0
0 0
Ce143 CeGrp NONE Pr143 6.64E+07 5.83E-06 0 4.77E-02 0 0
0 3.39E+03 0 0
0 0
0 0
Ce144 CeGrp NONE NONE 5.92E+07 2.82E-08 0 1.03E-02 0 0
0 3.74E+05 0 0
0 0
0 0
Np239 CeGrp NONE NONE 8.95E+08 3.41E-06 0 2.85E-02 0 0
0 2.51E+03 0 0
0 0
0 0
Pu238 CeGrp NONE NONE 2.10E+05 2.50E-10 0 1.81E-05 0 0
0 2.88E+08 0 0
0 0
0 0
Pu239 CeGrp NONE NONE 1.24E+04 9.13E-13 0 1.57E-05 0 0
0 3.08E+08 0 0
0 0
0 0
Pu240 CeGrp NONE NONE 2.00E+04 3.36E-12 0 1.76E-05 0 0
0 3.08E+08 0 0
0 0
0 0
Pu241 CeGrp NONE NONE 5.44E+06 1.53E-09 0 2.68E-07 0 0
0 4.96E+06 0 0
0 0
0 0
Sr89 SrGrp NONE NONE 3.95E+07 1.59E-07 0 2.86E-04 0 0
0 4.14E+04 0 0
0 0
0 0
Sr90 SrGrp NONE Y90 4.93E+06 7.54E-10 0 2.79E-05 0 0
0 1.30E+06 0 0
0 0
0 0
Sr91 SrGrp NONE Y91 4.93E+07 2.03E-05 0 1.82E-01 0 0
0 1.68E+03 0 0
0 0
0 0
Sr92 SrGrp NONE Y92 5.33E+07 7.10E-05 0 2.51E-01 0 0
0 8.07E+02 0 0
0 0
0 0
PSAT 3142CT.QA.04 Appendix Ab Page Ab1 of Ab2 Rev. 0 1 2 3 4 LIBFILE1.TXT - HB n_isotopes 77 n_isotope_groups 11 Kr85m N_Gas NONE NONE 1.04E+07 4.30E-05 0 2.77E-02 0 0
0 0
0 0
0 0
0 0
Kr85 N_Gas NONE NONE 6.88E+05 2.05E-09 0 4.40E-04 0 0
0 0
0 0
0 0
0 0
Kr87 N_Gas NONE NONE 2.03E+07 1.51E-04 0 1.52E-01 0 0
0 0
0 0
0 0
0 0
Kr88 N_Gas NONE Rb88 2.72E+07 6.78E-05 0 3.77E-01 0 0
0 0
0 0
0 0
0 0
Xe131m N_Gas NONE NONE 4.86E+05 6.74E-07 0 1.44E-03 0 0
0 0
0 0
0 0
0 0
Xe133m N_Gas NONE NONE 2.75E+06 3.67E-06 0 5.07E-03 0 0
0 0
0 0
0 0
0 0
Xe133 N_Gas I133Elem NONE 8.80E+07 1.53E-06 0 5.77E-03 0 0
0 0
0 0
0 0
0 0
Xe135m N_Gas NONE NONE 1.87E+07 7.56E-04 0 7.55E-02 0 0
0 0
0 0
0 0
0 0
Xe135 N_Gas I135Elem NONE 1.99E+07 2.12E-05 0 4.40E-02 0 0
0 0
0 0
0 0
0 0
Xe137 N_Gas NONE Cs137 7.91E+07 2.96E-03 0 3.03E-02 0 0
0 0
0 0
0 0
0 0
Xe138 N_Gas NONE Cs138 7.42E+07 6.80E-04 0 2.13E-01 0 0
0 0
0 0
0 0
0 0
I130Org Org_I NONE NONE 1.40E+06 1.56E-05 7.36E+04 3.85E-01 0 0
0 2.64E+03 0 0
0 0
0 0
I131Org Org_I NONE NONE 4.33E+07 9.98E-07 1.07E+06 6.73E-02 0 0
0 3.29E+04 0 0
0 0
0 0
I132Org Org_I NONE NONE 6.26E+07 8.37E-05 6.29E+03 4.14E-01 0 0
0 3.81E+02 0 0
0 0
0 0
I133Org Org_I NONE NONE 8.78E+07 9.26E-06 1.81E+05 1.09E-01 0 0
0 5.85E+03 0 0
0 0
0 0
I134Org Org_I NONE NONE 9.83E+07 2.20E-04 1.07E+03 4.81E-01 0 0
0 1.31E+02 0 0
0 0
0 0
I135Org Org_I NONE NONE 8.38E+07 2.91E-05 3.14E+04 3.07E-01 0 0
0 1.23E+03 0 0
0 0
0 0
I130Elem Elm_I NONE NONE 1.40E+06 1.56E-05 7.36E+04 3.85E-01 0 0
0 2.64E+03 0 0
0 0
0 0
I131Elem Elm_I Te131m NONE 4.33E+07 9.98E-07 1.07E+06 6.73E-02 0 0
0 3.29E+04 0 0
0 0
0 0
I132Elem Elm_I Te132 NONE 6.26E+07 8.37E-05 6.29E+03 4.14E-01 0 0
0 3.81E+02 0 0
0 0
0 0
I133Elem Elm_I NONE Xe133 8.78E+07 9.26E-06 1.81E+05 1.09E-01 0 0
0 5.85E+03 0 0
0 0
0 0
I134Elem Elm_I NONE NONE 9.83E+07 2.20E-04 1.07E+03 4.81E-01 0 0
0 1.31E+02 0 0
0 0
0 0
I135Elem Elm_I NONE Xe135 8.38E+07 2.91E-05 3.14E+04 3.07E-01 0 0
0 1.23E+03 0 0
0 0
0 0
I130Part Prt_I NONE NONE 1.40E+06 1.56E-05 7.36E+04 3.85E-01 0 0
0 2.64E+03 0 0
0 0
0 0
I131Part Prt_I NONE NONE 4.33E+07 9.98E-07 1.07E+06 6.73E-02 0 0
0 3.29E+04 0 0
0 0
0 0
I132Part Prt_I NONE NONE 6.26E+07 8.37E-05 6.29E+03 4.14E-01 0 0
0 3.81E+02 0 0
0 0
0 0
I133Part Prt_I NONE NONE 8.78E+07 9.26E-06 1.81E+05 1.09E-01 0 0
0 5.85E+03 0 0
0 0
0 0
I134Part Prt_I NONE NONE 9.83E+07 2.20E-04 1.07E+03 4.81E-01 0 0
0 1.31E+02 0 0
0 0
0 0
I135Part Prt_I NONE NONE 8.38E+07 2.91E-05 3.14E+04 3.07E-01 0 0
0 1.23E+03 0 0
0 0
0 0
Rb86 CsGrp NONE NONE 1.27E+05 4.30E-07 0 1.78E-02 0 0
0 6.62E+03 0 0
0 0
0 0
Rb88 CsGrp Kr88 NONE 2.77E+07 6.49E-04 0 1.24E-01 0 0
0 8.36E+01 0 0
0 0
0 0
Cs134 CsGrp NONE NONE 1.43E+07 1.07E-08 0 2.80E-01 0 0
0 4.63E+04 0 0
0 0
0 0
Cs136 CsGrp NONE NONE 3.00E+06 6.12E-07 0 3.92E-01 0 0
0 7.33E+03 0 0
0 0
0 0
Cs137 CsGrp Xe137 NONE 7.58E+06 7.32E-10 0 1.01E-01 0 0
0 3.19E+04 0 0
0 0
0 0
Cs138 CsGrp Xe138 NONE 8.13E+07 3.59E-04 0 4.48E-01 0 0
0 1.01E+02 0 0
0 0
0 0
Sb127 TeGrp NONE Te127 4.09E+06 2.08E-06 0 1.23E-01 0 0
0 6.03E+03 0 0
0 0
0 0
Sb129 TeGrp NONE NONE 1.25E+07 4.46E-05 0 2.64E-01 0 0
0 6.44E+02 0 0
0 0
0 0
PSAT 3142CT.QA.04 Appendix Ab Page Ab2 of Ab2 Rev. 0 1 2 3 4 Te127m TeGrp NONE NONE 7.08E+05 7.36E-08 0 5.44E-04 0 0
0 2.15E+04 0 0
0 0
0 0
Te127 TeGrp Sb127 NONE 4.05E+06 2.06E-05 0 8.95E-04 0 0
0 3.18E+02 0 0
0 0
0 0
Te129m TeGrp NONE NONE 2.26E+06 2.39E-07 0 1.23E-02 0 0
0 2.40E+04 0 0
0 0
0 0
Te131m TeGrp NONE I131Elem 8.56E+06 6.42E-06 0 2.76E-01 0 0
0 6.50E+03 0 0
0 0
0 0
Te132 TeGrp NONE I132Elem 6.11E+07 2.46E-06 0 3.81E-02 0 0
0 9.44E+03 0 0
0 0
0 0
Ba139 BaGrp NONE NONE 7.75E+07 1.40E-04 0 8.03E-03 0 0
0 1.72E+02 0 0
0 0
0 0
Ba140 BaGrp NONE La140 7.43E+07 6.30E-07 0 3.17E-02 0 0
0 3.74E+03 0 0
0 0
0 0
Mo99 NMtls NONE Tc99m 7.99E+07 2.92E-06 0 2.69E-02 0 0
0 3.96E+03 0 0
0 0
0 0
Tc99m NMtls Mo99 NONE 7.03E+07 3.20E-05 0 2.18E-02 0 0
0 3.26E+01 0 0
0 0
0 0
Ru103 NMtls NONE NONE 7.12E+07 2.04E-07 0 8.33E-02 0 0
0 8.96E+03 0 0
0 0
0 0
Ru105 NMtls NONE Rh105 5.05E+07 4.34E-05 0 1.41E-01 0 0
0 4.55E+02 0 0
0 0
0 0
Ru106 NMtls NONE NONE 2.96E+07 2.18E-08 0 3.85E-02 0 0
0 4.77E+05 0 0
0 0
0 0
Rh105 NMtls Ru105 NONE 4.75E+07 5.45E-06 0 1.38E-02 0 0
0 9.55E+02 0 0
0 0
0 0
Y90 LaGrp Sr90 NONE 5.76E+06 3.01E-06 0 7.03E-04 0 0
0 8.44E+03 0 0
0 0
0 0
Y91 LaGrp Sr91 NONE 5.13E+07 1.37E-07 0 9.62E-04 0 0
0 4.88E+04 0 0
0 0
0 0
Y92 LaGrp Sr92 NONE 5.28E+07 5.44E-05 0 4.81E-02 0 0
0 7.81E+02 0 0
0 0
0 0
Y93 LaGrp NONE NONE 6.04E+07 1.91E-05 0 1.78E-02 0 0
0 2.15E+03 0 0
0 0
0 0
Zr95 LaGrp NONE Nb95 7.22E+07 1.25E-07 0 1.33E-01 0 0
0 2.36E+04 0 0
0 0
0 0
Zr97 LaGrp NONE NONE 7.20E+07 1.14E-05 0 1.64E-01 0 0
0 4.33E+03 0 0
0 0
0 0
Nb95 LaGrp Zr95 NONE 7.35E+07 2.28E-07 0 1.38E-01 0 0
0 5.81E+03 0 0
0 0
0 0
La140 LaGrp Ba140 NONE 7.82E+07 4.78E-06 0 4.33E-01 0 0
0 4.85E+03 0 0
0 0
0 0
La141 LaGrp NONE Ce141 6.98E+07 4.90E-05 0 8.84E-03 0 0
0 5.81E+02 0 0
0 0
0 0
La142 LaGrp NONE NONE 6.72E+07 1.25E-04 0 5.33E-01 0 0
0 2.53E+02 0 0
0 0
0 0
Pr143 LaGrp Ce143 NONE 6.46E+07 5.92E-07 0 7.77E-05 0 0
0 8.10E+03 0 0
0 0
0 0
Nd147 LaGrp NONE NONE 2.78E+07 7.31E-07 0 2.29E-02 0 0
0 6.85E+03 0 0
0 0
0 0
Am241 LaGrp NONE NONE 6.29E+03 5.08E-11 0 3.03E-03 0 0
0 4.44E+08 0 0
0 0
0 0
Cm242 LaGrp NONE NONE 2.68E+06 4.93E-08 0 2.11E-05 0 0
0 1.73E+07 0 0
0 0
0 0
Cm244 LaGrp NONE NONE 5.89E+05 1.21E-09 0 1.82E-05 0 0
0 2.48E+08 0 0
0 0
0 0
Ce141 CeGrp La141 NONE 7.11E+07 2.47E-07 0 1.27E-02 0 0
0 8.95E+03 0 0
0 0
0 0
Ce143 CeGrp NONE Pr143 6.50E+07 5.83E-06 0 4.77E-02 0 0
0 3.39E+03 0 0
0 0
0 0
Ce144 CeGrp NONE NONE 6.01E+07 2.82E-08 0 1.03E-02 0 0
0 3.74E+05 0 0
0 0
0 0
Np239 CeGrp NONE NONE 8.73E+08 3.41E-06 0 2.85E-02 0 0
0 2.51E+03 0 0
0 0
0 0
Pu238 CeGrp NONE NONE 2.39E+05 2.50E-10 0 1.81E-05 0 0
0 2.88E+08 0 0
0 0
0 0
Pu239 CeGrp NONE NONE 1.39E+04 9.13E-13 0 1.57E-05 0 0
0 3.08E+08 0 0
0 0
0 0
Pu240 CeGrp NONE NONE 2.24E+04 3.36E-12 0 1.76E-05 0 0
0 3.08E+08 0 0
0 0
0 0
Pu241 CeGrp NONE NONE 6.07E+06 1.53E-09 0 2.68E-07 0 0
0 4.96E+06 0 0
0 0
0 0
Sr89 SrGrp NONE NONE 3.83E+07 1.59E-07 0 2.86E-04 0 0
0 4.14E+04 0 0
0 0
0 0
Sr90 SrGrp NONE Y90 5.49E+06 7.54E-10 0 2.79E-05 0 0
0 1.30E+06 0 0
0 0
0 0
Sr91 SrGrp NONE Y91 4.82E+07 2.03E-05 0 1.82E-01 0 0
0 1.68E+03 0 0
0 0
0 0
Sr92 SrGrp NONE Y92 5.22E+07 7.10E-05 0 2.51E-01 0 0
0 8.07E+02 0 0
0 0
0 0
PSAT 3142CT.QA.04 Appendix B Page B1 of B5 Rev. 0 1 2 3 4 INPUT.DAT for Prairie Island Nuclear Generating Plant edit_time 0
0.00056 0.01 0.0167 0.075 0.167 0.247 0.333 2
8 24 96 720 end_edit_time participating_isotopes Kr85m Kr85 Kr87 Kr88 Xe131m Xe133m Xe133 Xe135m Xe135 Xe137 Xe138 I130Org I130Elem I130Part I131Org I131Elem I131Part I132Org I132Elem I132Part I133Org I133Elem I133Part I135Org I135Elem I135Part I134Org I134Elem I134Part Rb86 Rb88 Cs134 Cs136 Cs137 Cs138 Sb127 Sb129 Te127m Te127 Te129m Te131m Te132 Ba139 Ba140 Mo99 Tc99m Ru103 Ru105 Ru106 Rh105 Y90 Y91 Y92 Y93 Zr95 Zr97 Nb95 La140 La141 La142 Pr143 Nd147 Am241 Cm242 Cm244 Ce141 Ce143 Ce144 Np239 Pu238 Pu239 Pu240 Pu241 Sr89 Sr90 Sr91 Sr92 end_participating_isotopes core thermal_power 1
elemental_iodine_frac 0.91 organic_iodine_frac 0.04 particulate_iodine_frac 0.05 release_frac to_control_volume PC Time N_Gas I_Grp CsGrp TeGrp BaGrp NMtls CeGrp LaGrp SrGrp 0.00056 1786 446 17.9 17.9 17.9 17.9 17.9 17.9 17.9 720 0
0 0
0 0
0 0
0 0
end_to_control_volume to_control_volume Sump Time N_Gas I_Grp CsGrp TeGrp BaGrp NMtls CeGrp LaGrp SrGrp 0.00056 0 446 0
0 0
0 0
0 0
720 0
0 0
0 0
0 0
0 0
end_to_control_volume end_release_frac end_core control_volume obj_type OBJ_CV name PC air_volume 1.32e6 water_volume 2.67e4 surface_area 0
has_recirc_filter false removal_rate_to_waterpool Time NobleGas ElemIodine OrgIodine PartIodine Solubles Insolubles 0.017 0
0 0
0 0
0 0.247 0
20 0
0.45 0.45 0.45 720.0 0
0 0
0 0
0
PSAT 3142CT.QA.04 Appendix B Page B2 of B5 Rev. 0 1 2 3 4 end_removal_rate_to_waterpool frac_4_daughter_resusp_from_water Time NobleGas ElemIodine OrgIodine PartIodine Solubles Insolubles 720 0
0 0
0 0
0 end_frac_4_daughter_resusp_from_water end_control_volume control_volume obj_type OBJ_CV name Sump air_volume 2.67e4 water_volume 0
surface_area 0
has_recirc_filter false end_control_volume control_volume obj_type OBJ_CV name SC air_volume 1.87e5 water_volume 0
surface_area 0
has_recirc_filter true recirc_flowrate Time (hr)
Value (cfm) 0.333 0
720 4000 end_recirc_flowrate recirc_filter_efficiency Time NobleGas ElemIodine OrgIodine PartIodine Solubles Insolubles 720 0
0.9 0.7 0.99 0.99 0.99 end_recirc_filter_efficiency frac_4_daughter_resusp_from_recirc_filter Time NobleGas ElemIodine OrgIodine PartIodine Solubles Insolubles 720 0
0 0
0 0
0 end_frac_4_daughter_resusp_from_recirc_filter end_control_volume junction junction_type AIR_JUNCTION downstream_location AIR_SPACE upstream CORE downstream PC has_filter false flow_rate Time (hr)
Value (cfm) 720 1
end_flow_rate end_junction junction junction_type AIR_JUNCTION downstream_location AIR_SPACE upstream CORE downstream Sump has_filter false
PSAT 3142CT.QA.04 Appendix B Page B3 of B5 Rev. 0 1 2 3 4 flow_rate Time (hr)
Value (cfm) 720 1
end_flow_rate end_junction junction junction_type AIR_JUNCTION downstream_location AIR_SPACE upstream PC downstream environment has_filter true flow_rate Time (hr)
Value (cfm) 0.00056 0
24 1.008 720 0.504 end_flow_rate filter_efficiency Time NobleGas ElemIodine OrgIodine PartIodine Solubles Insolubles 720 0
0.818 0.636 0.9 0.9 0.9 end_filter_efficiency frac_4_daughter_resusp Time NobleGas ElemIodine OrgIodine PartIodine Solubles Insolubles 720 0
0 0
0 0
0 end_frac_4_daughter_resusp X_over_Q_4_site_boundary Time (hr)
Value (s/m*3) 2 6.49e-4 720 0
end_X_over_Q_4_site_boundary X_over_Q_4_low_population_zone Time (hr)
Value (s/m*3) 8 3.71E-05 24 6.27E-06 96 1.09E-06 720 1.52E-07 end_X_over_Q_4_low_population_zone X_over_Q_4_ctrl_room Time (hr)
Value (s/m*3) 720 0
end_X_over_Q_4_ctrl_room end_junction junction junction_type AIR_JUNCTION downstream_location AIR_SPACE upstream PC downstream SC has_filter false flow_rate Time (hr)
Value (cfm) 24 1.28 720 0.64 end_flow_rate end_junction
PSAT 3142CT.QA.04 Appendix B Page B4 of B5 Rev. 0 1 2 3 4 junction junction_type AIR_JUNCTION downstream_location AIR_SPACE upstream SC downstream environment has_filter true flow_rate Time (hr)
Value (cfm) 0.01 1558.3 0.075 7558.3 0.167 3000 0.333 1300 720 1000 end_flow_rate filter_efficiency Time NobleGas ElemIodine OrgIodine PartIodine Solubles Insolubles 0.01 0
0 0
0 0
0 0.075 0
0.714 0.556 0.786 0.786 0.786 720 0
0.9 0.7 0.99 0.99 0.99 end_filter_efficiency frac_4_daughter_resusp Time NobleGas ElemIodine OrgIodine PartIodine Solubles Insolubles 720 0
0 0
0 0
0 end_frac_4_daughter_resusp X_over_Q_4_site_boundary Time (hr)
Value (s/m*3) 2 6.49e-4 720 0
end_X_over_Q_4_site_boundary X_over_Q_4_low_population_zone Time (hr)
Value (s/m*3) 8 3.71E-05 24 6.27E-06 96 1.09E-06 720 1.52E-07 end_X_over_Q_4_low_population_zone X_over_Q_4_ctrl_room Time (hr)
Value (s/m*3) 720 0
end_X_over_Q_4_ctrl_room end_junction junction junction_type AIR_JUNCTION downstream_location AIR_SPACE upstream Sump downstream Environment has_filter true flow_rate Time (hr)
Value (cfm) 720 0
end_flow_rate filter_efficiency Time NobleGas ElemIodine OrgIodine PartIodine Solubles Insolubles 720 0
0.89 1
1 1
1
PSAT 3142CT.QA.04 Appendix B Page B5 of B5 Rev. 0 1 2 3 4 end_filter_efficiency frac_4_daughter_resusp Time NobleGas ElemIodine OrgIodine PartIodine Solubles Insolubles 720 0
0 0
0 0
0 end_frac_4_daughter_resusp end_junction environment breathing_rate_sb Time (hr)
Value (cms) 8 0.00035 720 0.0 end_breathing_rate_sb breathing_rate_lpz Time (hr)
Value (cms) 8 0.00035 24 0.00018 720 0.00023 end_breathing_rate_lpz end_environment
PSAT 3142CT.QA.04 Appendix C Page C1 of C11 Rev. 0 1 2 3 4 Excerpts of RESULTS.OUT files for STARDOSE Analyses 2 Hours - OFA environment thyroid wbody skin CEDE EAB dose: 1.06E+001 1.26E+000 0.00E+000 6.74E+000 LPZ dose: 6.05E-001 7.20E-002 0.00E+000 3.85E-001 thyrd_eab wbody_eab skin_eab CEDE_eab thyrd_lpz wbody_lpz skin_lpz CEDE_lpz Noble gas 0.00E+000 1.16E+000 0.00E+000 0.00E+000 0.00E+000 6.64E-002 0.00E+000 0.00E+000 Org iodine 5.93E+000 2.04E-002 0.00E+000 1.88E-001 3.39E-001 1.17E-003 0.00E+000 1.07E-002 Elem iodine 3.06E+000 1.42E-002 0.00E+000 9.73E-002 1.75E-001 8.10E-004 0.00E+000 5.56E-003 Part iodine 1.60E+000 5.59E-003 0.00E+000 5.06E-002 9.14E-002 3.19E-004 0.00E+000 2.89E-003 Cesium 0.00E+000 4.93E-002 0.00E+000 2.27E-002 0.00E+000 2.82E-003 0.00E+000 1.30E-003 Tellurium 0.00E+000 4.53E-004 0.00E+000 1.45E-002 0.00E+000 2.59E-005 0.00E+000 8.30E-004 Barium 0.00E+000 1.56E-004 0.00E+000 5.70E-003 0.00E+000 8.93E-006 0.00E+000 3.26E-004 Noble metal 0.00E+000 9.94E-004 0.00E+000 2.85E-001 0.00E+000 5.68E-005 0.00E+000 1.63E-002 Lanthanides 0.00E+000 5.29E-003 0.00E+000 3.53E+000 0.00E+000 3.03E-004 0.00E+000 2.02E-001 Cerium 0.00E+000 1.66E-003 0.00E+000 2.39E+000 0.00E+000 9.50E-005 0.00E+000 1.37E-001 Strontinum 0.00E+000 1.04E-003 0.00E+000 1.59E-001 0.00E+000 5.97E-005 0.00E+000 9.09E-003 air_space thyrd_eab wbody_eab skin_eab CEDE_eab thyrd_lpz wbody_lpz skin_lpz CEDE_lpz Kr85m 1.11E+003 0.00E+000 2.00E-002 0.00E+000 0.00E+000 0.00E+000 1.14E-003 0.00E+000 0.00E+000 Kr85 7.64E+001 0.00E+000 2.25E-005 0.00E+000 0.00E+000 0.00E+000 1.29E-006 0.00E+000 0.00E+000 Kr87 1.50E+003 0.00E+000 1.45E-001 0.00E+000 0.00E+000 0.00E+000 8.31E-003 0.00E+000 0.00E+000 Kr88 2.64E+003 0.00E+000 6.46E-001 0.00E+000 0.00E+000 0.00E+000 3.69E-002 0.00E+000 0.00E+000 Xe131m 6.08E+001 0.00E+000 5.85E-005 0.00E+000 0.00E+000 0.00E+000 3.35E-006 0.00E+000 0.00E+000 Xe133m 3.40E+002 0.00E+000 1.15E-003 0.00E+000 0.00E+000 0.00E+000 6.57E-005 0.00E+000 0.00E+000 Xe133 1.10E+004 0.00E+000 4.14E-002 0.00E+000 0.00E+000 0.00E+000 2.36E-003 0.00E+000 0.00E+000 Xe135m 3.75E+002 0.00E+000 1.77E-002 0.00E+000 0.00E+000 0.00E+000 1.01E-003 0.00E+000 0.00E+000 Xe135 2.07E+003 0.00E+000 5.95E-002 0.00E+000 0.00E+000 0.00E+000 3.40E-003 0.00E+000 0.00E+000 Xe137 3.83E+002 0.00E+000 7.24E-003 0.00E+000 0.00E+000 0.00E+000 4.14E-004 0.00E+000 0.00E+000 Xe138 1.65E+003 0.00E+000 2.22E-001 0.00E+000 0.00E+000 0.00E+000 1.27E-002 0.00E+000 0.00E+000 I130Org 5.33E-001 8.94E-003 1.34E-004 0.00E+000 3.21E-004 5.11E-004 7.64E-006 0.00E+000 1.83E-005 I131Org 1.74E+001 4.26E+000 7.65E-004 0.00E+000 1.31E-001 2.43E-001 4.37E-005 0.00E+000 7.48E-003 I132Org 1.89E+001 2.67E-002 5.03E-003 0.00E+000 1.62E-003 1.53E-003 2.87E-004 0.00E+000 9.26E-005 I133Org 3.42E+001 1.41E+000 2.43E-003 0.00E+000 4.57E-002 8.07E-002 1.39E-004 0.00E+000 2.61E-003 I134Org 1.96E+001 4.68E-003 6.01E-003 0.00E+000 5.73E-004 2.67E-004 3.44E-004 0.00E+000 3.27E-005 I135Org 3.05E+001 2.17E-001 6.07E-003 0.00E+000 8.51E-003 1.24E-002 3.47E-004 0.00E+000 4.86E-004 I130Elem 2.91E-001 4.74E-003 7.09E-005 0.00E+000 1.70E-004 2.71E-004 4.05E-006 0.00E+000 9.72E-006 I131Elem 9.17E+000 2.17E+000 3.90E-004 0.00E+000 6.68E-002 1.24E-001 2.23E-005 0.00E+000 3.82E-003 I132Elem 1.44E+001 2.02E-002 3.81E-003 0.00E+000 1.23E-003 1.16E-003 2.18E-004 0.00E+000 7.01E-005 I133Elem 1.84E+001 7.39E-001 1.27E-003 0.00E+000 2.39E-002 4.22E-002 7.27E-005 0.00E+000 1.37E-003 I134Elem 1.75E+001 4.11E-003 5.29E-003 0.00E+000 5.04E-004 2.35E-004 3.02E-004 0.00E+000 2.88E-005
PSAT 3142CT.QA.04 Appendix C Page C2 of C11 Rev. 0 1 2 3 4 I135Elem 1.72E+001 1.20E-001 3.35E-003 0.00E+000 4.70E-003 6.85E-003 1.91E-004 0.00E+000 2.68E-004 I130Part 1.45E-001 2.41E-003 3.61E-005 0.00E+000 8.66E-005 1.38E-004 2.06E-006 0.00E+000 4.95E-006 I131Part 4.72E+000 1.15E+000 2.06E-004 0.00E+000 3.53E-002 6.56E-002 1.18E-005 0.00E+000 2.02E-003 I132Part 5.17E+000 7.30E-003 1.37E-003 0.00E+000 4.42E-004 4.17E-004 7.85E-005 0.00E+000 2.53E-005 I133Part 9.28E+000 3.81E-001 6.56E-004 0.00E+000 1.23E-002 2.18E-002 3.75E-005 0.00E+000 7.04E-004 I134Part 5.48E+000 1.30E-003 1.67E-003 0.00E+000 1.60E-004 7.45E-005 9.57E-005 0.00E+000 9.13E-006 I135Part 8.27E+000 5.88E-002 1.64E-003 0.00E+000 2.30E-003 3.36E-003 9.39E-005 0.00E+000 1.32E-004 Rb86 1.10E-002 0.00E+000 1.28E-007 0.00E+000 1.66E-005 0.00E+000 7.30E-009 0.00E+000 9.51E-007 Rb88 1.68E+002 0.00E+000 1.36E-002 0.00E+000 3.21E-003 0.00E+000 7.77E-004 0.00E+000 1.83E-004 Cs134 1.14E+000 0.00E+000 2.08E-004 0.00E+000 1.20E-002 0.00E+000 1.19E-005 0.00E+000 6.87E-004 Cs136 2.49E-001 0.00E+000 6.34E-005 0.00E+000 4.15E-004 0.00E+000 3.63E-006 0.00E+000 2.37E-005 Cs137 5.83E-001 0.00E+000 3.83E-005 0.00E+000 4.23E-003 0.00E+000 2.19E-006 0.00E+000 2.42E-004 Cs138 1.23E+002 0.00E+000 3.54E-002 0.00E+000 2.79E-003 0.00E+000 2.02E-003 0.00E+000 1.59E-004 Sb127 3.57E-001 0.00E+000 2.85E-005 0.00E+000 4.89E-004 0.00E+000 1.63E-006 0.00E+000 2.80E-005 Sb129 9.41E-001 0.00E+000 1.60E-004 0.00E+000 1.37E-004 0.00E+000 9.16E-006 0.00E+000 7.82E-006 Te127m 6.10E-002 0.00E+000 2.16E-008 0.00E+000 2.98E-004 0.00E+000 1.23E-009 0.00E+000 1.70E-005 Te127 3.54E-001 0.00E+000 2.06E-007 0.00E+000 2.56E-005 0.00E+000 1.18E-008 0.00E+000 1.47E-006 Te129m 1.98E-001 0.00E+000 1.58E-006 0.00E+000 1.08E-003 0.00E+000 9.04E-008 0.00E+000 6.18E-005 Te131m 7.34E-001 0.00E+000 1.31E-004 0.00E+000 1.08E-003 0.00E+000 7.51E-006 0.00E+000 6.19E-005 Te132 5.31E+000 0.00E+000 1.31E-004 0.00E+000 1.14E-002 0.00E+000 7.52E-006 0.00E+000 6.52E-004 Ba139 4.31E+000 0.00E+000 2.21E-005 0.00E+000 1.66E-004 0.00E+000 1.26E-006 0.00E+000 9.47E-006 Ba140 6.51E+000 0.00E+000 1.34E-004 0.00E+000 5.54E-003 0.00E+000 7.67E-006 0.00E+000 3.17E-004 Mo99 6.94E+000 0.00E+000 1.21E-004 0.00E+000 6.24E-003 0.00E+000 6.93E-006 0.00E+000 3.57E-004 Tc99m 6.25E+000 0.00E+000 8.86E-005 0.00E+000 4.64E-005 0.00E+000 5.06E-006 0.00E+000 2.65E-006 Ru103 6.25E+000 0.00E+000 3.38E-004 0.00E+000 1.27E-002 0.00E+000 1.93E-005 0.00E+000 7.28E-004 Ru105 3.82E+000 0.00E+000 3.48E-004 0.00E+000 3.93E-004 0.00E+000 1.99E-005 0.00E+000 2.25E-005 Ru106 2.44E+000 0.00E+000 6.12E-005 0.00E+000 2.65E-001 0.00E+000 3.50E-006 0.00E+000 1.52E-002 Rh105 4.14E+000 0.00E+000 3.71E-005 0.00E+000 8.99E-004 0.00E+000 2.12E-006 0.00E+000 5.14E-005 Y90 4.46E-001 0.00E+000 2.04E-007 0.00E+000 8.56E-004 0.00E+000 1.16E-008 0.00E+000 4.89E-005 Y91 4.49E+000 0.00E+000 2.81E-006 0.00E+000 4.99E-002 0.00E+000 1.61E-007 0.00E+000 2.85E-003 Y92 4.49E+000 0.00E+000 1.40E-004 0.00E+000 7.96E-004 0.00E+000 8.01E-006 0.00E+000 4.55E-005 Y93 4.95E+000 0.00E+000 5.70E-005 0.00E+000 2.41E-003 0.00E+000 3.26E-006 0.00E+000 1.38E-004 Zr95 6.30E+000 0.00E+000 5.45E-004 0.00E+000 3.38E-002 0.00E+000 3.11E-005 0.00E+000 1.93E-003 Zr97 6.06E+000 0.00E+000 6.45E-004 0.00E+000 5.96E-003 0.00E+000 3.69E-005 0.00E+000 3.41E-004 Nb95 6.42E+000 0.00E+000 5.75E-004 0.00E+000 8.48E-003 0.00E+000 3.29E-005 0.00E+000 4.85E-004
PSAT 3142CT.QA.04 Appendix C Page C3 of C11 Rev. 0 1 2 3 4 La140 6.86E+000 0.00E+000 1.93E-003 0.00E+000 7.57E-003 0.00E+000 1.10E-004 0.00E+000 4.33E-004 La141 5.17E+000 0.00E+000 2.94E-005 0.00E+000 6.77E-004 0.00E+000 1.68E-006 0.00E+000 3.87E-005 La142 3.91E+000 0.00E+000 1.33E-003 0.00E+000 2.21E-004 0.00E+000 7.62E-005 0.00E+000 1.27E-005 Pr143 5.66E+000 0.00E+000 2.86E-007 0.00E+000 1.04E-002 0.00E+000 1.63E-008 0.00E+000 5.96E-004 Nd147 2.42E+000 0.00E+000 3.60E-005 0.00E+000 3.77E-003 0.00E+000 2.06E-006 0.00E+000 2.16E-004 Am241 4.27E-004 0.00E+000 8.41E-010 0.00E+000 4.31E-002 0.00E+000 4.81E-011 0.00E+000 2.47E-003 Cm242 2.03E-001 0.00E+000 2.79E-009 0.00E+000 8.00E-001 0.00E+000 1.59E-010 0.00E+000 4.57E-002 Cm244 4.54E-002 0.00E+000 5.37E-010 0.00E+000 2.56E+000 0.00E+000 3.07E-011 0.00E+000 1.46E-001 Ce141 6.23E+000 0.00E+000 5.14E-005 0.00E+000 1.27E-002 0.00E+000 2.94E-006 0.00E+000 7.24E-004 Ce143 5.58E+000 0.00E+000 1.73E-004 0.00E+000 4.30E-003 0.00E+000 9.87E-006 0.00E+000 2.46E-004 Ce144 5.08E+000 0.00E+000 3.40E-005 0.00E+000 4.32E-001 0.00E+000 1.94E-006 0.00E+000 2.47E-002 Np239 7.58E+001 0.00E+000 1.40E-003 0.00E+000 4.33E-002 0.00E+000 8.02E-005 0.00E+000 2.47E-003 Pu238 1.80E-002 0.00E+000 2.12E-010 0.00E+000 1.18E+000 0.00E+000 1.21E-011 0.00E+000 6.74E-002 Pu239 1.06E-003 0.00E+000 1.09E-011 0.00E+000 7.45E-002 0.00E+000 6.20E-013 0.00E+000 4.26E-003 Pu240 1.72E-003 0.00E+000 1.96E-011 0.00E+000 1.20E-001 0.00E+000 1.12E-012 0.00E+000 6.87E-003 Pu241 4.67E-001 0.00E+000 8.13E-011 0.00E+000 5.26E-001 0.00E+000 4.65E-012 0.00E+000 3.01E-002 Sr89 3.39E+000 0.00E+000 6.29E-007 0.00E+000 3.19E-002 0.00E+000 3.60E-008 0.00E+000 1.82E-003 Sr90 4.23E-001 0.00E+000 7.67E-009 0.00E+000 1.25E-001 0.00E+000 4.38E-010 0.00E+000 7.15E-003 Sr91 3.94E+000 0.00E+000 4.64E-004 0.00E+000 1.50E-003 0.00E+000 2.65E-005 0.00E+000 8.57E-005 Sr92 3.59E+000 0.00E+000 5.80E-004 0.00E+000 6.52E-004 0.00E+000 3.31E-005 0.00E+000 3.73E-005 720 Hours - OFA environment thyroid wbody skin CEDE EAB dose: 1.06E+001 1.26E+000 0.00E+000 6.74E+000 LPZ dose: 2.43E+000 1.88E-001 0.00E+000 2.04E+000 thyrd_eab wbody_eab skin_eab CEDE_eab thyrd_lpz wbody_lpz skin_lpz CEDE_lpz Noble gas 0.00E+000 1.16E+000 0.00E+000 0.00E+000 0.00E+000 1.75E-001 0.00E+000 0.00E+000 Org iodine 5.93E+000 2.04E-002 0.00E+000 1.88E-001 1.68E+000 3.19E-003 0.00E+000 5.27E-002 Elem iodine 3.06E+000 1.42E-002 0.00E+000 9.73E-002 3.21E-001 1.64E-003 0.00E+000 1.02E-002 Part iodine 1.60E+000 5.59E-003 0.00E+000 5.06E-002 4.25E-001 8.24E-004 0.00E+000 1.33E-002 Cesium 0.00E+000 4.93E-002 0.00E+000 2.27E-002 0.00E+000 4.65E-003 0.00E+000 5.83E-003 Tellurium 0.00E+000 4.53E-004 0.00E+000 1.45E-002 0.00E+000 1.11E-004 0.00E+000 3.90E-003 Barium 0.00E+000 1.56E-004 0.00E+000 5.70E-003 0.00E+000 4.75E-005 0.00E+000 1.62E-003 Noble metal 0.00E+000 9.94E-004 0.00E+000 2.85E-001 0.00E+000 2.75E-004 0.00E+000 8.74E-002 Lanthanides 0.00E+000 5.29E-003 0.00E+000 3.53E+000 0.00E+000 1.41E-003 0.00E+000 1.09E+000 Cerium 0.00E+000 1.66E-003 0.00E+000 2.39E+000 0.00E+000 4.95E-004 0.00E+000 7.36E-001 Strontinum 0.00E+000 1.04E-003 0.00E+000 1.59E-001 0.00E+000 1.70E-004 0.00E+000 4.86E-002 air_space thyrd_eab wbody_eab skin_eab CEDE_eab thyrd_lpz wbody_lpz skin_lpz CEDE_lpz Kr85m 5.75E+003 0.00E+000 2.00E-002 0.00E+000 0.00E+000 0.00E+000 4.16E-003 0.00E+000 0.00E+000 Kr85 2.35E+004 0.00E+000 2.25E-005 0.00E+000 0.00E+000 0.00E+000 1.22E-005 0.00E+000 0.00E+000
PSAT 3142CT.QA.04 Appendix C Page C4 of C11 Rev. 0 1 2 3 4 Kr87 2.59E+003 0.00E+000 1.45E-001 0.00E+000 0.00E+000 0.00E+000 1.39E-002 0.00E+000 0.00E+000 Kr88 8.94E+003 0.00E+000 6.46E-001 0.00E+000 0.00E+000 0.00E+000 1.06E-001 0.00E+000 0.00E+000 Xe131m 9.22E+003 0.00E+000 5.85E-005 0.00E+000 0.00E+000 0.00E+000 2.88E-005 0.00E+000 0.00E+000 Xe133m 1.37E+004 0.00E+000 1.15E-003 0.00E+000 0.00E+000 0.00E+000 4.84E-004 0.00E+000 0.00E+000 Xe133 9.21E+005 0.00E+000 4.14E-002 0.00E+000 0.00E+000 0.00E+000 1.94E-002 0.00E+000 0.00E+000 Xe135m 3.77E+002 0.00E+000 1.77E-002 0.00E+000 0.00E+000 0.00E+000 1.02E-003 0.00E+000 0.00E+000 Xe135 2.06E+004 0.00E+000 5.95E-002 0.00E+000 0.00E+000 0.00E+000 1.71E-002 0.00E+000 0.00E+000 Xe137 3.83E+002 0.00E+000 7.24E-003 0.00E+000 0.00E+000 0.00E+000 4.14E-004 0.00E+000 0.00E+000 Xe138 1.67E+003 0.00E+000 2.22E-001 0.00E+000 0.00E+000 0.00E+000 1.28E-002 0.00E+000 0.00E+000 I130Org 4.66E+000 8.94E-003 1.34E-004 0.00E+000 3.21E-004 1.99E-003 3.21E-005 0.00E+000 7.14E-005 I131Org 1.30E+003 4.26E+000 7.65E-004 0.00E+000 1.31E-001 1.29E+000 2.70E-004 0.00E+000 3.95E-002 I132Org 4.35E+001 2.67E-002 5.03E-003 0.00E+000 1.62E-003 3.17E-003 6.01E-004 0.00E+000 1.92E-004 I133Org 4.40E+002 1.41E+000 2.43E-003 0.00E+000 4.57E-002 3.47E-001 6.60E-004 0.00E+000 1.12E-002 I134Org 2.51E+001 4.68E-003 6.01E-003 0.00E+000 5.73E-004 3.39E-004 4.36E-004 0.00E+000 4.15E-005 I135Org 1.64E+002 2.17E-001 6.07E-003 0.00E+000 8.51E-003 4.08E-002 1.19E-003 0.00E+000 1.60E-003 I130Elem 7.21E-001 4.74E-003 7.09E-005 0.00E+000 1.70E-004 4.27E-004 6.62E-006 0.00E+000 1.53E-005 I131Elem 1.58E+002 2.17E+000 3.90E-004 0.00E+000 6.68E-002 2.36E-001 4.66E-005 0.00E+000 7.26E-003 I132Elem 3.68E+002 2.02E-002 3.81E-003 0.00E+000 1.23E-003 3.99E-003 8.68E-004 0.00E+000 2.42E-004 I133Elem 6.06E+001 7.39E-001 1.27E-003 0.00E+000 2.39E-002 7.03E-002 1.28E-004 0.00E+000 2.27E-003 I134Elem 1.80E+001 4.11E-003 5.29E-003 0.00E+000 5.04E-004 2.43E-004 3.12E-004 0.00E+000 2.98E-005 I135Elem 3.12E+001 1.20E-001 3.35E-003 0.00E+000 4.70E-003 9.85E-003 2.81E-004 0.00E+000 3.86E-004 I130Part 1.17E+000 2.41E-003 3.61E-005 0.00E+000 8.66E-005 5.07E-004 8.17E-006 0.00E+000 1.82E-005 I131Part 3.25E+002 1.15E+000 2.06E-004 0.00E+000 3.53E-002 3.25E-001 6.81E-005 0.00E+000 1.00E-002 I132Part 1.13E+001 7.30E-003 1.37E-003 0.00E+000 4.42E-004 8.28E-004 1.57E-004 0.00E+000 5.01E-005 I133Part 1.10E+002 3.81E-001 6.56E-004 0.00E+000 1.23E-002 8.83E-002 1.67E-004 0.00E+000 2.85E-003 I134Part 6.86E+000 1.30E-003 1.67E-003 0.00E+000 1.60E-004 9.25E-005 1.19E-004 0.00E+000 1.13E-005 I135Part 4.16E+001 5.88E-002 1.64E-003 0.00E+000 2.30E-003 1.04E-002 3.05E-004 0.00E+000 4.09E-004 Rb86 1.23E+000 0.00E+000 1.28E-007 0.00E+000 1.66E-005 0.00E+000 4.43E-008 0.00E+000 4.90E-006 Rb88 5.46E+002 0.00E+000 1.36E-002 0.00E+000 3.21E-003 0.00E+000 2.17E-003 0.00E+000 5.04E-004 Cs134 2.03E+002 0.00E+000 2.08E-004 0.00E+000 1.20E-002 0.00E+000 7.63E-005 0.00E+000 3.70E-003 Cs136 2.34E+001 0.00E+000 6.34E-005 0.00E+000 4.15E-004 0.00E+000 2.16E-005 0.00E+000 1.21E-004 Cs137 1.05E+002 0.00E+000 3.83E-005 0.00E+000 4.23E-003 0.00E+000 1.41E-005 0.00E+000 1.31E-003 Cs138 1.45E+002 0.00E+000 3.54E-002 0.00E+000 2.79E-003 0.00E+000 2.37E-003 0.00E+000 1.87E-004 Sb127 1.37E+001 0.00E+000 2.85E-005 0.00E+000 4.89E-004 0.00E+000 8.89E-006 0.00E+000 1.33E-004 Sb129 3.36E+000 0.00E+000 1.60E-004 0.00E+000 1.37E-004 0.00E+000 2.50E-005 0.00E+000 2.08E-005
PSAT 3142CT.QA.04 Appendix C Page C5 of C11 Rev. 0 1 2 3 4 Te127m 1.01E+001 0.00E+000 2.16E-008 0.00E+000 2.98E-004 0.00E+000 7.84E-009 0.00E+000 9.11E-005 Te127 1.50E+001 0.00E+000 2.06E-007 0.00E+000 2.56E-005 0.00E+000 6.69E-008 0.00E+000 7.19E-006 Te129m 2.70E+001 0.00E+000 1.58E-006 0.00E+000 1.08E-003 0.00E+000 5.61E-007 0.00E+000 3.24E-004 Te131m 1.14E+001 0.00E+000 1.31E-004 0.00E+000 1.08E-003 0.00E+000 3.59E-005 0.00E+000 2.65E-004 Te132 1.77E+002 0.00E+000 1.31E-004 0.00E+000 1.14E-002 0.00E+000 4.05E-005 0.00E+000 3.06E-003 Ba139 6.74E+000 0.00E+000 2.21E-005 0.00E+000 1.66E-004 0.00E+000 1.92E-006 0.00E+000 1.44E-005 Ba140 6.03E+002 0.00E+000 1.34E-004 0.00E+000 5.54E-003 0.00E+000 4.56E-005 0.00E+000 1.61E-003 Mo99 2.01E+002 0.00E+000 1.21E-004 0.00E+000 6.24E-003 0.00E+000 3.66E-005 0.00E+000 1.65E-003 Tc99m 2.15E+002 0.00E+000 8.86E-005 0.00E+000 4.64E-005 0.00E+000 2.92E-005 0.00E+000 1.32E-005 Ru103 8.87E+002 0.00E+000 3.38E-004 0.00E+000 1.27E-002 0.00E+000 1.21E-004 0.00E+000 3.83E-003 Ru105 1.40E+001 0.00E+000 3.48E-004 0.00E+000 3.93E-004 0.00E+000 5.49E-005 0.00E+000 6.03E-005 Ru106 4.30E+002 0.00E+000 6.12E-005 0.00E+000 2.65E-001 0.00E+000 2.24E-005 0.00E+000 8.16E-002 Rh105 8.08E+001 0.00E+000 3.71E-005 0.00E+000 8.99E-004 0.00E+000 1.10E-005 0.00E+000 2.36E-004 Y90 7.70E+001 0.00E+000 2.04E-007 0.00E+000 8.56E-004 0.00E+000 7.43E-008 0.00E+000 2.62E-004 Y91 6.93E+002 0.00E+000 2.81E-006 0.00E+000 4.99E-002 0.00E+000 1.01E-006 0.00E+000 1.52E-002 Y92 2.04E+001 0.00E+000 1.40E-004 0.00E+000 7.96E-004 0.00E+000 2.64E-005 0.00E+000 1.45E-004 Y93 3.45E+001 0.00E+000 5.70E-005 0.00E+000 2.41E-003 0.00E+000 1.22E-005 0.00E+000 4.83E-004 Zr95 9.79E+002 0.00E+000 5.45E-004 0.00E+000 3.38E-002 0.00E+000 1.96E-004 0.00E+000 1.03E-002 Zr97 6.19E+001 0.00E+000 6.45E-004 0.00E+000 5.96E-003 0.00E+000 1.58E-004 0.00E+000 1.33E-003 Nb95 1.13E+003 0.00E+000 5.75E-004 0.00E+000 8.48E-003 0.00E+000 2.11E-004 0.00E+000 2.61E-003 La140 6.82E+002 0.00E+000 1.93E-003 0.00E+000 7.57E-003 0.00E+000 6.66E-004 0.00E+000 2.22E-003 La141 1.71E+001 0.00E+000 2.94E-005 0.00E+000 6.77E-004 0.00E+000 4.40E-006 0.00E+000 9.88E-005 La142 6.54E+000 0.00E+000 1.33E-003 0.00E+000 2.21E-004 0.00E+000 1.23E-004 0.00E+000 2.04E-005 Pr143 5.92E+002 0.00E+000 2.86E-007 0.00E+000 1.04E-002 0.00E+000 9.95E-008 0.00E+000 3.08E-003 Nd147 2.05E+002 0.00E+000 3.60E-005 0.00E+000 3.77E-003 0.00E+000 1.21E-005 0.00E+000 1.09E-003 Am241 7.72E-002 0.00E+000 8.41E-010 0.00E+000 4.31E-002 0.00E+000 3.10E-010 0.00E+000 1.33E-002 Cm242 3.46E+001 0.00E+000 2.79E-009 0.00E+000 8.00E-001 0.00E+000 1.02E-009 0.00E+000 2.45E-001 Cm244 8.19E+000 0.00E+000 5.37E-010 0.00E+000 2.56E+000 0.00E+000 1.98E-010 0.00E+000 7.90E-001 Ce141 8.46E+002 0.00E+000 5.14E-005 0.00E+000 1.27E-002 0.00E+000 1.83E-005 0.00E+000 3.81E-003 Ce143 9.36E+001 0.00E+000 1.73E-004 0.00E+000 4.30E-003 0.00E+000 4.78E-005 0.00E+000 1.06E-003 Ce144 8.86E+002 0.00E+000 3.40E-005 0.00E+000 4.32E-001 0.00E+000 1.24E-005 0.00E+000 1.33E-001 Np239 1.94E+003 0.00E+000 1.40E-003 0.00E+000 4.33E-002 0.00E+000 4.16E-004 0.00E+000 1.13E-002 Pu238 3.25E+000 0.00E+000 2.12E-010 0.00E+000 1.18E+000 0.00E+000 7.80E-011 0.00E+000 3.64E-001 Pu239 1.92E-001 0.00E+000 1.09E-011 0.00E+000 7.45E-002 0.00E+000 3.99E-012 0.00E+000 2.30E-002 Pu240 3.10E-001 0.00E+000 1.96E-011 0.00E+000 1.20E-001 0.00E+000 7.22E-012 0.00E+000 3.71E-002
PSAT 3142CT.QA.04 Appendix C Page C6 of C11 Rev. 0 1 2 3 4 Pu241 8.42E+001 0.00E+000 8.13E-011 0.00E+000 5.26E-001 0.00E+000 2.99E-011 0.00E+000 1.62E-001 Sr89 5.06E+002 0.00E+000 6.29E-007 0.00E+000 3.19E-002 0.00E+000 2.26E-007 0.00E+000 9.65E-003 Sr90 7.63E+001 0.00E+000 7.67E-009 0.00E+000 1.25E-001 0.00E+000 2.82E-009 0.00E+000 3.86E-002 Sr91 2.62E+001 0.00E+000 4.64E-004 0.00E+000 1.50E-003 0.00E+000 9.74E-005 0.00E+000 2.95E-004 Sr92 8.89E+000 0.00E+000 5.80E-004 0.00E+000 6.52E-004 0.00E+000 7.21E-005 0.00E+000 8.03E-005 STARDOSE 1.01 (c) 1996-2002 Polestar Applied Technology, Inc.
Tue Apr 29 08:54:30 2008 Total elapsed hours: 0, mins: 0, secs: 3 2 Hours - HB environment thyroid wbody skin CEDE EAB dose: 1.04E+001 1.24E+000 0.00E+000 7.42E+000 LPZ dose: 5.92E-001 7.10E-002 0.00E+000 4.24E-001 thyrd_eab wbody_eab skin_eab CEDE_eab thyrd_lpz wbody_lpz skin_lpz CEDE_lpz Noble gas 0.00E+000 1.14E+000 0.00E+000 0.00E+000 0.00E+000 6.54E-002 0.00E+000 0.00E+000 Org iodine 5.80E+000 1.99E-002 0.00E+000 1.83E-001 3.31E-001 1.14E-003 0.00E+000 1.05E-002 Elem iodine 2.99E+000 1.38E-002 0.00E+000 9.51E-002 1.71E-001 7.91E-004 0.00E+000 5.44E-003 Part iodine 1.56E+000 5.46E-003 0.00E+000 4.95E-002 8.94E-002 3.12E-004 0.00E+000 2.83E-003 Cesium 0.00E+000 4.82E-002 0.00E+000 2.40E-002 0.00E+000 2.76E-003 0.00E+000 1.37E-003 Tellurium 0.00E+000 4.43E-004 0.00E+000 1.42E-002 0.00E+000 2.53E-005 0.00E+000 8.11E-004 Barium 0.00E+000 1.53E-004 0.00E+000 5.57E-003 0.00E+000 8.72E-006 0.00E+000 3.18E-004 Noble metal 0.00E+000 9.75E-004 0.00E+000 2.95E-001 0.00E+000 5.57E-005 0.00E+000 1.69E-002 Lanthanides 0.00E+000 5.18E-003 0.00E+000 3.93E+000 0.00E+000 2.96E-004 0.00E+000 2.25E-001 Cerium 0.00E+000 1.62E-003 0.00E+000 2.65E+000 0.00E+000 9.28E-005 0.00E+000 1.51E-001 Strontinum 0.00E+000 1.02E-003 0.00E+000 1.72E-001 0.00E+000 5.84E-005 0.00E+000 9.85E-003 air_space thyrd_eab wbody_eab skin_eab CEDE_eab thyrd_lpz wbody_lpz skin_lpz CEDE_lpz Kr85m 1.08E+003 0.00E+000 1.96E-002 0.00E+000 0.00E+000 0.00E+000 1.12E-003 0.00E+000 0.00E+000 Kr85 8.43E+001 0.00E+000 2.48E-005 0.00E+000 0.00E+000 0.00E+000 1.42E-006 0.00E+000 0.00E+000 Kr87 1.46E+003 0.00E+000 1.42E-001 0.00E+000 0.00E+000 0.00E+000 8.11E-003 0.00E+000 0.00E+000 Kr88 2.59E+003 0.00E+000 6.35E-001 0.00E+000 0.00E+000 0.00E+000 3.63E-002 0.00E+000 0.00E+000 Xe131m 5.94E+001 0.00E+000 5.72E-005 0.00E+000 0.00E+000 0.00E+000 3.27E-006 0.00E+000 0.00E+000 Xe133m 3.32E+002 0.00E+000 1.12E-003 0.00E+000 0.00E+000 0.00E+000 6.43E-005 0.00E+000 0.00E+000 Xe133 1.07E+004 0.00E+000 4.05E-002 0.00E+000 0.00E+000 0.00E+000 2.31E-003 0.00E+000 0.00E+000 Xe135m 3.65E+002 0.00E+000 1.73E-002 0.00E+000 0.00E+000 0.00E+000 9.88E-004 0.00E+000 0.00E+000 Xe135 2.26E+003 0.00E+000 6.50E-002 0.00E+000 0.00E+000 0.00E+000 3.71E-003 0.00E+000 0.00E+000 Xe137 3.74E+002 0.00E+000 7.08E-003 0.00E+000 0.00E+000 0.00E+000 4.05E-004 0.00E+000 0.00E+000 Xe138 1.62E+003 0.00E+000 2.17E-001 0.00E+000 0.00E+000 0.00E+000 1.24E-002 0.00E+000 0.00E+000 I130Org 5.22E-001 8.75E-003 1.31E-004 0.00E+000 3.14E-004 5.00E-004 7.48E-006 0.00E+000 1.79E-005 I131Org 1.70E+001 4.16E+000 7.48E-004 0.00E+000 1.28E-001 2.38E-001 4.28E-005 0.00E+000 7.32E-003 I132Org 1.84E+001 2.61E-002 4.91E-003 0.00E+000 1.58E-003 1.49E-003 2.81E-004 0.00E+000 9.04E-005 I133Org 3.35E+001 1.38E+000 2.38E-003 0.00E+000 4.47E-002 7.90E-002 1.36E-004 0.00E+000 2.55E-003
PSAT 3142CT.QA.04 Appendix C Page C7 of C11 Rev. 0 1 2 3 4 I134Org 1.91E+001 4.55E-003 5.85E-003 0.00E+000 5.57E-004 2.60E-004 3.34E-004 0.00E+000 3.19E-005 I135Org 2.98E+001 2.12E-001 5.93E-003 0.00E+000 8.32E-003 1.21E-002 3.39E-004 0.00E+000 4.75E-004 I130Elem 2.85E-001 4.64E-003 6.94E-005 0.00E+000 1.66E-004 2.65E-004 3.97E-006 0.00E+000 9.52E-006 I131Elem 8.96E+000 2.12E+000 3.81E-004 0.00E+000 6.53E-002 1.21E-001 2.18E-005 0.00E+000 3.73E-003 I132Elem 1.41E+001 1.98E-002 3.72E-003 0.00E+000 1.20E-003 1.13E-003 2.13E-004 0.00E+000 6.85E-005 I133Elem 1.80E+001 7.23E-001 1.24E-003 0.00E+000 2.34E-002 4.14E-002 7.12E-005 0.00E+000 1.34E-003 I134Elem 1.70E+001 4.00E-003 5.14E-003 0.00E+000 4.90E-004 2.29E-004 2.94E-004 0.00E+000 2.80E-005 I135Elem 1.68E+001 1.17E-001 3.28E-003 0.00E+000 4.59E-003 6.70E-003 1.87E-004 0.00E+000 2.63E-004 I130Part 1.42E-001 2.36E-003 3.53E-005 0.00E+000 8.48E-005 1.35E-004 2.02E-006 0.00E+000 4.85E-006 I131Part 4.61E+000 1.12E+000 2.02E-004 0.00E+000 3.45E-002 6.41E-002 1.15E-005 0.00E+000 1.97E-003 I132Part 5.04E+000 7.13E-003 1.34E-003 0.00E+000 4.32E-004 4.08E-004 7.66E-005 0.00E+000 2.47E-005 I133Part 9.08E+000 3.73E-001 6.42E-004 0.00E+000 1.21E-002 2.13E-002 3.67E-005 0.00E+000 6.89E-004 I134Part 5.33E+000 1.27E-003 1.63E-003 0.00E+000 1.55E-004 7.25E-005 9.32E-005 0.00E+000 8.88E-006 I135Part 8.09E+000 5.75E-002 1.61E-003 0.00E+000 2.25E-003 3.29E-003 9.18E-005 0.00E+000 1.29E-004 Rb86 1.09E-002 0.00E+000 1.26E-007 0.00E+000 1.64E-005 0.00E+000 7.19E-009 0.00E+000 9.36E-007 Rb88 1.65E+002 0.00E+000 1.33E-002 0.00E+000 3.15E-003 0.00E+000 7.63E-004 0.00E+000 1.80E-004 Cs134 1.23E+000 0.00E+000 2.23E-004 0.00E+000 1.29E-002 0.00E+000 1.28E-005 0.00E+000 7.38E-004 Cs136 2.57E-001 0.00E+000 6.54E-005 0.00E+000 4.28E-004 0.00E+000 3.74E-006 0.00E+000 2.45E-005 Cs137 6.50E-001 0.00E+000 4.27E-005 0.00E+000 4.72E-003 0.00E+000 2.44E-006 0.00E+000 2.70E-004 Cs138 1.20E+002 0.00E+000 3.46E-002 0.00E+000 2.73E-003 0.00E+000 1.98E-003 0.00E+000 1.56E-004 Sb127 3.48E-001 0.00E+000 2.78E-005 0.00E+000 4.77E-004 0.00E+000 1.59E-006 0.00E+000 2.73E-005 Sb129 9.19E-001 0.00E+000 1.57E-004 0.00E+000 1.34E-004 0.00E+000 8.95E-006 0.00E+000 7.64E-006 Te127m 6.07E-002 0.00E+000 2.15E-008 0.00E+000 2.97E-004 0.00E+000 1.23E-009 0.00E+000 1.70E-005 Te127 3.48E-001 0.00E+000 2.02E-007 0.00E+000 2.51E-005 0.00E+000 1.16E-008 0.00E+000 1.44E-006 Te129m 1.94E-001 0.00E+000 1.55E-006 0.00E+000 1.06E-003 0.00E+000 8.85E-008 0.00E+000 6.04E-005 Te131m 7.18E-001 0.00E+000 1.29E-004 0.00E+000 1.06E-003 0.00E+000 7.35E-006 0.00E+000 6.06E-005 Te132 5.20E+000 0.00E+000 1.29E-004 0.00E+000 1.11E-002 0.00E+000 7.35E-006 0.00E+000 6.37E-004 Ba139 4.22E+000 0.00E+000 2.16E-005 0.00E+000 1.62E-004 0.00E+000 1.24E-006 0.00E+000 9.27E-006 Ba140 6.36E+000 0.00E+000 1.31E-004 0.00E+000 5.41E-003 0.00E+000 7.49E-006 0.00E+000 3.09E-004 Mo99 6.78E+000 0.00E+000 1.18E-004 0.00E+000 6.11E-003 0.00E+000 6.77E-006 0.00E+000 3.49E-004 Tc99m 6.11E+000 0.00E+000 8.66E-005 0.00E+000 4.53E-005 0.00E+000 4.95E-006 0.00E+000 2.59E-006 Ru103 6.10E+000 0.00E+000 3.30E-004 0.00E+000 1.24E-002 0.00E+000 1.89E-005 0.00E+000 7.11E-004 Ru105 3.73E+000 0.00E+000 3.39E-004 0.00E+000 3.83E-004 0.00E+000 1.94E-005 0.00E+000 2.19E-005 Ru106 2.54E+000 0.00E+000 6.35E-005 0.00E+000 2.75E-001 0.00E+000 3.63E-006 0.00E+000 1.57E-002 Rh105 4.07E+000 0.00E+000 3.65E-005 0.00E+000 8.84E-004 0.00E+000 2.09E-006 0.00E+000 5.05E-005
PSAT 3142CT.QA.04 Appendix C Page C8 of C11 Rev. 0 1 2 3 4 Y90 4.94E-001 0.00E+000 2.26E-007 0.00E+000 9.48E-004 0.00E+000 1.29E-008 0.00E+000 5.42E-005 Y91 4.40E+000 0.00E+000 2.75E-006 0.00E+000 4.88E-002 0.00E+000 1.57E-007 0.00E+000 2.79E-003 Y92 4.40E+000 0.00E+000 1.37E-004 0.00E+000 7.80E-004 0.00E+000 7.85E-006 0.00E+000 4.46E-005 Y93 4.84E+000 0.00E+000 5.58E-005 0.00E+000 2.36E-003 0.00E+000 3.19E-006 0.00E+000 1.35E-004 Zr95 6.19E+000 0.00E+000 5.35E-004 0.00E+000 3.32E-002 0.00E+000 3.06E-005 0.00E+000 1.90E-003 Zr97 5.93E+000 0.00E+000 6.31E-004 0.00E+000 5.83E-003 0.00E+000 3.61E-005 0.00E+000 3.33E-004 Nb95 6.30E+000 0.00E+000 5.65E-004 0.00E+000 8.33E-003 0.00E+000 3.23E-005 0.00E+000 4.76E-004 La140 6.70E+000 0.00E+000 1.89E-003 0.00E+000 7.39E-003 0.00E+000 1.08E-004 0.00E+000 4.23E-004 La141 5.06E+000 0.00E+000 2.88E-005 0.00E+000 6.63E-004 0.00E+000 1.65E-006 0.00E+000 3.79E-005 La142 3.82E+000 0.00E+000 1.30E-003 0.00E+000 2.16E-004 0.00E+000 7.45E-005 0.00E+000 1.24E-005 Pr143 5.54E+000 0.00E+000 2.80E-007 0.00E+000 1.02E-002 0.00E+000 1.60E-008 0.00E+000 5.83E-004 Nd147 2.38E+000 0.00E+000 3.54E-005 0.00E+000 3.70E-003 0.00E+000 2.02E-006 0.00E+000 2.12E-004 Am241 5.40E-004 0.00E+000 1.06E-009 0.00E+000 5.45E-002 0.00E+000 6.07E-011 0.00E+000 3.11E-003 Cm242 2.30E-001 0.00E+000 3.15E-009 0.00E+000 9.04E-001 0.00E+000 1.80E-010 0.00E+000 5.17E-002 Cm244 5.05E-002 0.00E+000 5.97E-010 0.00E+000 2.85E+000 0.00E+000 3.42E-011 0.00E+000 1.63E-001 Ce141 6.10E+000 0.00E+000 5.03E-005 0.00E+000 1.24E-002 0.00E+000 2.88E-006 0.00E+000 7.09E-004 Ce143 5.46E+000 0.00E+000 1.69E-004 0.00E+000 4.21E-003 0.00E+000 9.67E-006 0.00E+000 2.40E-004 Ce144 5.15E+000 0.00E+000 3.45E-005 0.00E+000 4.38E-001 0.00E+000 1.97E-006 0.00E+000 2.51E-002 Np239 7.40E+001 0.00E+000 1.37E-003 0.00E+000 4.22E-002 0.00E+000 7.83E-005 0.00E+000 2.41E-003 Pu238 2.05E-002 0.00E+000 2.41E-010 0.00E+000 1.34E+000 0.00E+000 1.38E-011 0.00E+000 7.68E-002 Pu239 1.19E-003 0.00E+000 1.22E-011 0.00E+000 8.35E-002 0.00E+000 6.95E-013 0.00E+000 4.77E-003 Pu240 1.92E-003 0.00E+000 2.20E-011 0.00E+000 1.35E-001 0.00E+000 1.26E-012 0.00E+000 7.69E-003 Pu241 5.21E-001 0.00E+000 9.07E-011 0.00E+000 5.87E-001 0.00E+000 5.18E-012 0.00E+000 3.36E-002 Sr89 3.28E+000 0.00E+000 6.10E-007 0.00E+000 3.09E-002 0.00E+000 3.49E-008 0.00E+000 1.77E-003 Sr90 4.71E-001 0.00E+000 8.54E-009 0.00E+000 1.39E-001 0.00E+000 4.88E-010 0.00E+000 7.96E-003 Sr91 3.85E+000 0.00E+000 4.54E-004 0.00E+000 1.47E-003 0.00E+000 2.59E-005 0.00E+000 8.38E-005 Sr92 3.52E+000 0.00E+000 5.68E-004 0.00E+000 6.39E-004 0.00E+000 3.24E-005 0.00E+000 3.65E-005 720 Hours - HB environment thyroid wbody skin CEDE EAB dose: 1.04E+001 1.24E+000 0.00E+000 7.42E+000 LPZ dose: 2.37E+000 1.86E-001 0.00E+000 2.25E+000 thyrd_eab wbody_eab skin_eab CEDE_eab thyrd_lpz wbody_lpz skin_lpz CEDE_lpz Noble gas 0.00E+000 1.14E+000 0.00E+000 0.00E+000 0.00E+000 1.74E-001 0.00E+000 0.00E+000 Org iodine 5.80E+000 1.99E-002 0.00E+000 1.83E-001 1.64E+000 3.12E-003 0.00E+000 5.15E-002 Elem iodine 2.99E+000 1.38E-002 0.00E+000 9.51E-002 3.14E-001 1.60E-003 0.00E+000 9.97E-003 Part iodine 1.56E+000 5.46E-003 0.00E+000 4.95E-002 4.16E-001 8.05E-004 0.00E+000 1.30E-002 Cesium 0.00E+000 4.82E-002 0.00E+000 2.40E-002 0.00E+000 4.57E-003 0.00E+000 6.24E-003
PSAT 3142CT.QA.04 Appendix C Page C9 of C11 Rev. 0 1 2 3 4 Tellurium 0.00E+000 4.43E-004 0.00E+000 1.42E-002 0.00E+000 1.08E-004 0.00E+000 3.82E-003 Barium 0.00E+000 1.53E-004 0.00E+000 5.57E-003 0.00E+000 4.64E-005 0.00E+000 1.58E-003 Noble metal 0.00E+000 9.75E-004 0.00E+000 2.95E-001 0.00E+000 2.70E-004 0.00E+000 9.04E-002 Lanthanides 0.00E+000 5.18E-003 0.00E+000 3.93E+000 0.00E+000 1.38E-003 0.00E+000 1.21E+000 Cerium 0.00E+000 1.62E-003 0.00E+000 2.65E+000 0.00E+000 4.83E-004 0.00E+000 8.14E-001 Strontinum 0.00E+000 1.02E-003 0.00E+000 1.72E-001 0.00E+000 1.66E-004 0.00E+000 5.27E-002 air_space thyrd_eab wbody_eab skin_eab CEDE_eab thyrd_lpz wbody_lpz skin_lpz CEDE_lpz Kr85m 5.65E+003 0.00E+000 1.96E-002 0.00E+000 0.00E+000 0.00E+000 4.08E-003 0.00E+000 0.00E+000 Kr85 2.60E+004 0.00E+000 2.48E-005 0.00E+000 0.00E+000 0.00E+000 1.34E-005 0.00E+000 0.00E+000 Kr87 2.53E+003 0.00E+000 1.42E-001 0.00E+000 0.00E+000 0.00E+000 1.36E-002 0.00E+000 0.00E+000 Kr88 8.78E+003 0.00E+000 6.35E-001 0.00E+000 0.00E+000 0.00E+000 1.04E-001 0.00E+000 0.00E+000 Xe131m 9.02E+003 0.00E+000 5.72E-005 0.00E+000 0.00E+000 0.00E+000 2.81E-005 0.00E+000 0.00E+000 Xe133m 1.34E+004 0.00E+000 1.12E-003 0.00E+000 0.00E+000 0.00E+000 4.73E-004 0.00E+000 0.00E+000 Xe133 9.02E+005 0.00E+000 4.05E-002 0.00E+000 0.00E+000 0.00E+000 1.90E-002 0.00E+000 0.00E+000 Xe135m 3.67E+002 0.00E+000 1.73E-002 0.00E+000 0.00E+000 0.00E+000 9.94E-004 0.00E+000 0.00E+000 Xe135 2.25E+004 0.00E+000 6.50E-002 0.00E+000 0.00E+000 0.00E+000 1.86E-002 0.00E+000 0.00E+000 Xe137 3.74E+002 0.00E+000 7.08E-003 0.00E+000 0.00E+000 0.00E+000 4.05E-004 0.00E+000 0.00E+000 Xe138 1.64E+003 0.00E+000 2.17E-001 0.00E+000 0.00E+000 0.00E+000 1.26E-002 0.00E+000 0.00E+000 I130Org 4.57E+000 8.75E-003 1.31E-004 0.00E+000 3.14E-004 1.95E-003 3.15E-005 0.00E+000 6.99E-005 I131Org 1.27E+003 4.16E+000 7.48E-004 0.00E+000 1.28E-001 1.26E+000 2.64E-004 0.00E+000 3.86E-002 I132Org 4.25E+001 2.61E-002 4.91E-003 0.00E+000 1.58E-003 3.10E-003 5.87E-004 0.00E+000 1.88E-004 I133Org 4.31E+002 1.38E+000 2.38E-003 0.00E+000 4.47E-002 3.40E-001 6.46E-004 0.00E+000 1.10E-002 I134Org 2.45E+001 4.55E-003 5.85E-003 0.00E+000 5.57E-004 3.30E-004 4.24E-004 0.00E+000 4.04E-005 I135Org 1.61E+002 2.12E-001 5.93E-003 0.00E+000 8.32E-003 3.99E-002 1.17E-003 0.00E+000 1.56E-003 I130Elem 7.06E-001 4.64E-003 6.94E-005 0.00E+000 1.66E-004 4.18E-004 6.48E-006 0.00E+000 1.50E-005 I131Elem 1.54E+002 2.12E+000 3.81E-004 0.00E+000 6.53E-002 2.31E-001 4.56E-005 0.00E+000 7.09E-003 I132Elem 3.60E+002 1.98E-002 3.72E-003 0.00E+000 1.20E-003 3.90E-003 8.48E-004 0.00E+000 2.36E-004 I133Elem 5.93E+001 7.23E-001 1.24E-003 0.00E+000 2.34E-002 6.88E-002 1.25E-004 0.00E+000 2.22E-003 I134Elem 1.76E+001 4.00E-003 5.14E-003 0.00E+000 4.90E-004 2.37E-004 3.04E-004 0.00E+000 2.90E-005 I135Elem 3.05E+001 1.17E-001 3.28E-003 0.00E+000 4.59E-003 9.63E-003 2.75E-004 0.00E+000 3.77E-004 I130Part 1.15E+000 2.36E-003 3.53E-005 0.00E+000 8.48E-005 4.96E-004 8.00E-006 0.00E+000 1.78E-005 I131Part 3.18E+002 1.12E+000 2.02E-004 0.00E+000 3.45E-002 3.18E-001 6.65E-005 0.00E+000 9.78E-003 I132Part 1.11E+001 7.13E-003 1.34E-003 0.00E+000 4.32E-004 8.08E-004 1.53E-004 0.00E+000 4.90E-005 I133Part 1.08E+002 3.73E-001 6.42E-004 0.00E+000 1.21E-002 8.64E-002 1.64E-004 0.00E+000 2.79E-003 I134Part 6.68E+000 1.27E-003 1.63E-003 0.00E+000 1.55E-004 9.00E-005 1.16E-004 0.00E+000 1.10E-005 I135Part 4.07E+001 5.75E-002 1.61E-003 0.00E+000 2.25E-003 1.02E-002 2.98E-004 0.00E+000 4.00E-004 Rb86 1.22E+000 0.00E+000 1.26E-007 0.00E+000 1.64E-005 0.00E+000 4.36E-008 0.00E+000 4.82E-006 Rb88 5.36E+002 0.00E+000 1.33E-002 0.00E+000 3.15E-003 0.00E+000 2.13E-003 0.00E+000 4.95E-004
PSAT 3142CT.QA.04 Appendix C Page C10 of C11 Rev. 0 1 2 3 4 Cs134 2.19E+002 0.00E+000 2.23E-004 0.00E+000 1.29E-002 0.00E+000 8.20E-005 0.00E+000 3.98E-003 Cs136 2.41E+001 0.00E+000 6.54E-005 0.00E+000 4.28E-004 0.00E+000 2.23E-005 0.00E+000 1.24E-004 Cs137 1.17E+002 0.00E+000 4.27E-005 0.00E+000 4.72E-003 0.00E+000 1.57E-005 0.00E+000 1.46E-003 Cs138 1.41E+002 0.00E+000 3.46E-002 0.00E+000 2.73E-003 0.00E+000 2.32E-003 0.00E+000 1.83E-004 Sb127 1.34E+001 0.00E+000 2.78E-005 0.00E+000 4.77E-004 0.00E+000 8.68E-006 0.00E+000 1.30E-004 Sb129 3.28E+000 0.00E+000 1.57E-004 0.00E+000 1.34E-004 0.00E+000 2.44E-005 0.00E+000 2.03E-005 Te127m 1.00E+001 0.00E+000 2.15E-008 0.00E+000 2.97E-004 0.00E+000 7.80E-009 0.00E+000 9.08E-005 Te127 1.46E+001 0.00E+000 2.02E-007 0.00E+000 2.51E-005 0.00E+000 6.55E-008 0.00E+000 7.04E-006 Te129m 2.64E+001 0.00E+000 1.55E-006 0.00E+000 1.06E-003 0.00E+000 5.49E-007 0.00E+000 3.17E-004 Te131m 1.12E+001 0.00E+000 1.29E-004 0.00E+000 1.06E-003 0.00E+000 3.51E-005 0.00E+000 2.59E-004 Te132 1.73E+002 0.00E+000 1.29E-004 0.00E+000 1.11E-002 0.00E+000 3.96E-005 0.00E+000 2.99E-003 Ba139 6.60E+000 0.00E+000 2.16E-005 0.00E+000 1.62E-004 0.00E+000 1.88E-006 0.00E+000 1.41E-005 Ba140 5.88E+002 0.00E+000 1.31E-004 0.00E+000 5.41E-003 0.00E+000 4.45E-005 0.00E+000 1.57E-003 Mo99 1.96E+002 0.00E+000 1.18E-004 0.00E+000 6.11E-003 0.00E+000 3.58E-005 0.00E+000 1.62E-003 Tc99m 2.10E+002 0.00E+000 8.66E-005 0.00E+000 4.53E-005 0.00E+000 2.85E-005 0.00E+000 1.29E-005 Ru103 8.66E+002 0.00E+000 3.30E-004 0.00E+000 1.24E-002 0.00E+000 1.18E-004 0.00E+000 3.74E-003 Ru105 1.36E+001 0.00E+000 3.39E-004 0.00E+000 3.83E-004 0.00E+000 5.35E-005 0.00E+000 5.88E-005 Ru106 4.47E+002 0.00E+000 6.35E-005 0.00E+000 2.75E-001 0.00E+000 2.33E-005 0.00E+000 8.48E-002 Rh105 7.94E+001 0.00E+000 3.65E-005 0.00E+000 8.84E-004 0.00E+000 1.08E-005 0.00E+000 2.32E-004 Y90 8.57E+001 0.00E+000 2.26E-007 0.00E+000 9.48E-004 0.00E+000 8.23E-008 0.00E+000 2.91E-004 Y91 6.78E+002 0.00E+000 2.75E-006 0.00E+000 4.88E-002 0.00E+000 9.93E-007 0.00E+000 1.48E-002 Y92 2.00E+001 0.00E+000 1.37E-004 0.00E+000 7.80E-004 0.00E+000 2.59E-005 0.00E+000 1.42E-004 Y93 3.37E+001 0.00E+000 5.58E-005 0.00E+000 2.36E-003 0.00E+000 1.19E-005 0.00E+000 4.73E-004 Zr95 9.62E+002 0.00E+000 5.35E-004 0.00E+000 3.32E-002 0.00E+000 1.93E-004 0.00E+000 1.01E-002 Zr97 6.06E+001 0.00E+000 6.31E-004 0.00E+000 5.83E-003 0.00E+000 1.54E-004 0.00E+000 1.30E-003 Nb95 1.11E+003 0.00E+000 5.65E-004 0.00E+000 8.33E-003 0.00E+000 2.07E-004 0.00E+000 2.56E-003 La140 6.66E+002 0.00E+000 1.89E-003 0.00E+000 7.39E-003 0.00E+000 6.50E-004 0.00E+000 2.17E-003 La141 1.67E+001 0.00E+000 2.88E-005 0.00E+000 6.63E-004 0.00E+000 4.30E-006 0.00E+000 9.67E-005 La142 6.40E+000 0.00E+000 1.30E-003 0.00E+000 2.16E-004 0.00E+000 1.20E-004 0.00E+000 1.99E-005 Pr143 5.79E+002 0.00E+000 2.80E-007 0.00E+000 1.02E-002 0.00E+000 9.74E-008 0.00E+000 3.02E-003 Nd147 2.02E+002 0.00E+000 3.54E-005 0.00E+000 3.70E-003 0.00E+000 1.19E-005 0.00E+000 1.07E-003 Am241 9.75E-002 0.00E+000 1.06E-009 0.00E+000 5.45E-002 0.00E+000 3.91E-010 0.00E+000 1.68E-002 Cm242 3.91E+001 0.00E+000 3.15E-009 0.00E+000 9.04E-001 0.00E+000 1.15E-009 0.00E+000 2.77E-001 Cm244 9.12E+000 0.00E+000 5.97E-010 0.00E+000 2.85E+000 0.00E+000 2.20E-010 0.00E+000 8.80E-001 Ce141 8.29E+002 0.00E+000 5.03E-005 0.00E+000 1.24E-002 0.00E+000 1.79E-005 0.00E+000 3.73E-003
PSAT 3142CT.QA.04 Appendix C Page C11 of C11 Rev. 0 1 2 3 4 Ce143 9.16E+001 0.00E+000 1.69E-004 0.00E+000 4.21E-003 0.00E+000 4.67E-005 0.00E+000 1.04E-003 Ce144 9.00E+002 0.00E+000 3.45E-005 0.00E+000 4.38E-001 0.00E+000 1.26E-005 0.00E+000 1.35E-001 Np239 1.89E+003 0.00E+000 1.37E-003 0.00E+000 4.22E-002 0.00E+000 4.06E-004 0.00E+000 1.10E-002 Pu238 3.70E+000 0.00E+000 2.41E-010 0.00E+000 1.34E+000 0.00E+000 8.88E-011 0.00E+000 4.15E-001 Pu239 2.15E-001 0.00E+000 1.22E-011 0.00E+000 8.35E-002 0.00E+000 4.48E-012 0.00E+000 2.58E-002 Pu240 3.47E-001 0.00E+000 2.20E-011 0.00E+000 1.35E-001 0.00E+000 8.09E-012 0.00E+000 4.16E-002 Pu241 9.39E+001 0.00E+000 9.07E-011 0.00E+000 5.87E-001 0.00E+000 3.34E-011 0.00E+000 1.81E-001 Sr89 4.91E+002 0.00E+000 6.10E-007 0.00E+000 3.09E-002 0.00E+000 2.19E-007 0.00E+000 9.35E-003 Sr90 8.50E+001 0.00E+000 8.54E-009 0.00E+000 1.39E-001 0.00E+000 3.14E-009 0.00E+000 4.30E-002 Sr91 2.56E+001 0.00E+000 4.54E-004 0.00E+000 1.47E-003 0.00E+000 9.52E-005 0.00E+000 2.89E-004 Sr92 8.71E+000 0.00E+000 5.68E-004 0.00E+000 6.39E-004 0.00E+000 7.06E-005 0.00E+000 7.86E-005 STARDOSE 1.01 (c) 1996-2002 Polestar Applied Technology, Inc.
Tue Apr 29 08:53:47 2008 Total elapsed hours: 0, mins: 0, secs: 3
PSAT 3142CT.QA.04 Appendix D Page D1 of D5 Rev. 0 1 2 3 4 MicroShield Analysis for Long-Term EQ Dose Rates Introduction This appendix presents the MicroShield analyses performed to project the external exposure dose rates beyond the 30-day dose integration of the STARDOSE analysis. In these analyses, the STARDOSE output at t = 0.00056 hours (two seconds) for the two cases presented in Appendix C are used as input to STARGATE (reference [D1]) to extract relevant activity information for the containment. The.MX7 (external source) files created by STARGATE are read by MicroShield (reference [D2] as input to a shine analysis, but no shine analysis is actually conducted. Rather, the source is decayed for 90 days and 180 days (after the noble gas radionuclides have been deleted) to provide the long-term waterborne gamma radiation source term consistent with the release to containment. There is a question regarding whether the iodine contribution to the waterborne source term should have been increased by a factor of two (to account for 50% iodine release rather than 25% iodine release); but even the relatively long-lived I-131 will have gone though 11.2 half-lives by 90 days, so the contribution of another 25% of iodine at t = 90 days (or t = 180 days) should have a negligible effect, and this has been confirmed.
.MX7 Files The two t = 0.MX7 files prepared by STARGATE after the noble gas has been removed are as follows (first for OFA fuel):
7.02 MS source file created: Wed Apr 30 06:52:59 2008 for edit time=.000560 (hr) from results-ofa.out 1
1 : Indicator for Ci or Photons/sec 1 : Geometry factor (point, cm, cm^2, or cm^3) 54 : Number of nuclides in file.
Nuclide Index Ci Nuclide Name 332 1.29E+003 Rb-86 334 3.01E+005 Rb-88 115 1.33E+005 Cs-134 118 2.92E+004 Cs-136 119 6.82E+004 Cs-137 120 8.60E+005 Cs-138 365 4.20E+004 Sb-127 366 1.28E+005 Sb-129 416 7.13E+003 Te-127m 415 4.14E+004 Te-127 418 2.32E+004 Te-129m 420 8.77E+004 Te-131m 421 6.26E+005 Te-132 41 7.94E+005 Ba-139 42 7.63E+005 Ba-140 224 8.19E+005 Mo-99 408 7.21E+005 Tc-99m 355 7.31E+005 Ru-103 356 5.19E+005 Ru-105 357 2.86E+005 Ru-106 347 4.84E+005 Rh-105 480 5.21E+004 Y-90 482 5.25E+005 Y-91 484 5.40E+005 Y-92 485 6.18E+005 Y-93 496 7.37E+005 Zr-95 497 7.38E+005 Zr-97
PSAT 3142CT.QA.04 Appendix D Page D2 of D5 Rev. 0 1 2 3 4 238 7.50E+005 Nb-95 209 8.03E+005 La-140 210 7.15E+005 La-141 211 6.88E+005 La-142 302 6.62E+005 Pr-143 243 2.84E+005 Nd-147 13 4.99E+001 Am-241 93 2.38E+004 Cm-242 95 5.30E+003 Cm-244 81 7.28E+005 Ce-141 82 6.66E+005 Ce-143 83 5.93E+005 Ce-144 255 8.97E+006 Np-239 313 2.11E+003 Pu-238 314 1.24E+002 Pu-239 315 2.00E+002 Pu-240 316 5.45E+004 Pu-241 391 3.96E+005 Sr-89 392 4.94E+004 Sr-90 393 4.94E+005 Sr-91 394 5.34E+005 Sr-92 174 3.57E+005 I-130 175 1.11E+007 I-131 176 1.60E+007 I-132 177 2.24E+007 I-133 178 2.52E+007 I-134 179 2.14E+007 I-135 Energy Activity (Photons/sec) 0 0 Energy # 1 0 0 Energy # 2 0 0 Energy # 3 0 0 Energy # 4 0 0 Energy # 5 0 0 Energy # 6 0 0 Energy # 7 0 0 Energy # 8 0 0 Energy # 9 0 0 Energy # 10 0 0 Energy # 11 0 0 Energy # 12 0 0 Energy # 13 0 0 Energy # 14 0 0 Energy # 15 0 0 Energy # 16 0 0 Energy # 17 0 0 Energy # 18 0 0 Energy # 19 0 0 Energy # 20 0 0 Energy # 21 0 0 Energy # 22 0 0 Energy # 23 0 0 Energy # 24 0 0 Energy # 25 And for HB fuel:
7.02 MS source file created: Wed Apr 30 06:58:45 2008 for edit time=.000560 (hr) from results-HB.out 1
1 : Indicator for Ci or Photons/sec 1 : Geometry factor (point, cm, cm^2, or cm^3) 54 : Number of nuclides in file.
Nuclide Index Ci Nuclide Name 332 1.27E+003 Rb-86 334 2.95E+005 Rb-88 115 1.43E+005 Cs-134 118 3.01E+004 Cs-136 119 7.60E+004 Cs-137 120 8.41E+005 Cs-138
PSAT 3142CT.QA.04 Appendix D Page D3 of D5 Rev. 0 1 2 3 4 365 4.10E+004 Sb-127 366 1.25E+005 Sb-129 416 7.10E+003 Te-127m 415 4.06E+004 Te-127 418 2.27E+004 Te-129m 420 8.58E+004 Te-131m 421 6.12E+005 Te-132 41 7.77E+005 Ba-139 42 7.45E+005 Ba-140 224 8.01E+005 Mo-99 408 7.05E+005 Tc-99m 355 7.14E+005 Ru-103 356 5.06E+005 Ru-105 357 2.97E+005 Ru-106 347 4.76E+005 Rh-105 480 5.77E+004 Y-90 482 5.14E+005 Y-91 484 5.29E+005 Y-92 485 6.05E+005 Y-93 496 7.24E+005 Zr-95 497 7.22E+005 Zr-97 238 7.37E+005 Nb-95 209 7.84E+005 La-140 210 7.00E+005 La-141 211 6.73E+005 La-142 302 6.48E+005 Pr-143 243 2.79E+005 Nd-147 13 6.31E+001 Am-241 93 2.69E+004 Cm-242 95 5.90E+003 Cm-244 81 7.13E+005 Ce-141 82 6.52E+005 Ce-143 83 6.02E+005 Ce-144 255 8.75E+006 Np-239 313 2.40E+003 Pu-238 314 1.39E+002 Pu-239 315 2.25E+002 Pu-240 316 6.08E+004 Pu-241 391 3.84E+005 Sr-89 392 5.50E+004 Sr-90 393 4.83E+005 Sr-91 394 5.23E+005 Sr-92 174 3.50E+005 I-130 175 1.08E+007 I-131 176 1.56E+007 I-132 177 2.20E+007 I-133 178 2.45E+007 I-134 179 2.09E+007 I-135 Energy Activity (Photons/sec) 0 0 Energy # 1 0 0 Energy # 2 0 0 Energy # 3 0 0 Energy # 4 0 0 Energy # 5 0 0 Energy # 6 0 0 Energy # 7 0 0 Energy # 8 0 0 Energy # 9 0 0 Energy # 10 0 0 Energy # 11 0 0 Energy # 12 0 0 Energy # 13 0 0 Energy # 14 0 0 Energy # 15 0 0 Energy # 16 0 0 Energy # 17 0 0 Energy # 18 0 0 Energy # 19 0 0 Energy # 20 0 0 Energy # 21 0 0 Energy # 22
PSAT 3142CT.QA.04 Appendix D Page D4 of D5 Rev. 0 1 2 3 4 0 0 Energy # 23 0 0 Energy # 24 0 0 Energy # 25 Results Graphically, the dose rates are as follows; 90-Day Waterborne Source 0.00E+00 4.00E+15 8.00E+15 1.20E+16 1.60E+16 2.00E+16 2.40E+16 2.80E+16 3.20E+16 0.015 0.020 0.030 0.040 0.050 0.060 0.080 0.100 0.150 0.200 0.300 0.400 0.500 0.600 0.800 1.000 1.500 2.000 3.000 MeV Photons/sec OFA HB
PSAT 3142CT.QA.04 Appendix D Page D5 of D5 Rev. 0 1 2 3 4 180-Day Waterborne Source 0.00E+00 2.00E+15 4.00E+15 6.00E+15 8.00E+15 1.00E+16 1.20E+16 1.40E+16 1.60E+16 0.015 0.020 0.030 0.040 0.050 0.060 0.080 0.100 0.150 0.200 0.300 0.400 0.500 0.600 0.800 1.000 1.500 2.000 3.000 MeV Photons/sec OFA HB As is evident from these plots, the EQ dose rates due to waterborne sources at t = 90 days would be about the same for the two core inventories (the HB fuel being only 1% higher in terms of total photons/sec and actually less than the OFA fuel for the dominant 0.8 MeV group), and at t =
180 days, the HB fuel being only 3% greater. The late contribution (30 to 180 days) will be comparable to that for the first 30 days in spite of the time duration being five times greater. If one assumes the average MeV/sec over the 150 day interval from 30 to 180 days is that equal to the point value at t = 90 days (~3.7E16 MeV/sec, a reasonable assumption given that the point value at t = 180 days is ~55% of that at t = 90 days), the rem-m3 from t = 30 days to t = 180 days would be approximately (0.25 rem-m3-disintegration/Ci-sec-MeV from RG 1.4)/(3.7E10 disintegrations/sec-Ci)
- 3.7E16 MeV/sec
- 1.3E7 seconds = 3.25E12 rem-m3. For the HB fuel, the rem-m3 value might be of the order of 1% greater than that for the OFA fuel; i.e., ~3E10 rem-m3 greater. The margin at t = 30 days (OFA minus HB) is ~4E10 rem-m3. Therefore, the OFA fuel would be expected to be bounding even at t = 180 days.
References D1. PSAT CI18.QA.07, STARGATE Programming Report and PSAT CI18.QA.03, Dedication of MicroShield and STARGATE D2. PSAT CI18.QA.04, MicroShield Users Manual, Version 7, October, 2006, Grove Software, Inc. and PSAT CI18.QA.03, Dedication of MicroShield and STARGATE