Final Status Survey Final Report Phase V, Appendix A11, Survey Unit Release Record 9807-0000, Subsurface Area Associated with the Southwest Site Storage Area
ML072900174
Person / Time
Site: Haddam Neck File:Connecticut Yankee Atomic Power Co icon.png
Issue date: 12/31/2006
From: Mccarthy J
Connecticut Yankee Atomic Power Co
To:
NRC/FSME
References
9807-0000
Download: ML072900174 (174)


Text

"Zn..

N "mN~*

'.*';.vt......

N "4

"N p

N' 2;

'*.:ý Fin a IStatus Surv y Fn aiR p

r h

s 4

t*~n ~xA~1

~

3 1/24**Kb2' ~i

d. T K *<

~\\L i~ &L~

24 $2;

~

N' December 2006 A~rea

.CYAPCO FINAL STATUS SURVEY RELEASE RECORD SUBSURFACE AREA ASSOCIATED WITH THE SOUTHWEST SITE STORAGE AREA SURVEY UNIT 9807-0000 Prepared By:

Reviewed Bv FSS Engineer J

Date:,L.,/co6 Datell/ZiJO(

Date: 1 12(.,/.06 Approved By:_____________

Technical Support Manager Revision 0

SUBSURFACE AREA ASSOCIATED WITH THE SOUTHWEST SITE STORAGE AREA SURVEY UNIT 9807-0000 RELEASE RECORD TABLE OF CONTENTS

1.

SURVEY UNIT DESCRIPTION......................................................

3

2.

CLA SSIFICATION BASIS................................................................

3

3.

DATA QUALITY OBJECTIVES (DQO).........................................

5

4.

SU RV EY D ESIG N.............................................................................

8

5.

SURVEY IM PLEM ENTATION..........................................................

11

6.

SU RV EY RESU LTS........................................................................

12

7.

Q UA LITY CON TRO L......................................................................

14

8.

INVESTIGATIONS AND RESULTS.............................................

14

9.

REMEDIATION AND RESULTS..................................................

14

10. CHANGES FROM THE FINAL STATUS SURVEY PLAN......

14

11.

DATA QUALITY ASSESSMENT (DQA).......................................

14

12. A N O M A LIE S..................................................................................

15

13. C O N C LU SIO N.................................................................................

15

14. ATTACHMENTS........................................

16 14.1 - Figures (4 pages including cover) 14.2 Attachment 2 - Laboratory Data (137 pages including cover) 14.3 Attachment 3 - DQA Results (16 pages including covers)

TOTAL 173 Revision I

SUBSURFACE AREA ASSOCIATED WITH THE SOUTHWEST SITE STORAGE AREA SURVEY UNIT 9807-0000 RELEASE RECORD

1.

SURVEY UNIT DESCRIPTION Survey Unit 9807-0000 (Subsurface Area associated with the Southwest Site Storage Area) is designated as Final Status Survey (FSS) Class B and consists of 1,983 m2 (0.5 acres) of uninhabited open land located approximately 1,860 feet from the reference coordinate system benchmark used at Haddam Neck Plant (HNP) (see Attachment 1). The surface area is bounded by Survey Unit 9520-0004. The surface land unit that resides above this subsurface survey unit is relatively level open space of the peninsula. The restoration of the peninsula for FSS has removed most of the surface interference in the survey unit.

The reference coordinates associated with this survey unit are E007 through E0I10 by S089 through S093 (refer to License Termination Plan (LTP) Section 5.4.4).

The reference coordinates provide the maximum dimensions of a rectangle containing this survey unit. Some areas contained in this rectangle may. not be part of this survey unit. The boundary of the survey unit was defined using a Global Positioning System (GPS) based on the Connecticut State Plane System North American Datum (NAD) 1927.

2.

CLASSIFICATION BASIS The survey unit was classified in accordance with Procedure RPM 5.1-10, "Survey Unit Classification."

The "Classification Basis Summary" conducted for Survey Unit 9807-0000 consisted of:

a) A review of the 10CFR50.75 (g) (1) database, b) A review of the "Initial Characterization Report" and the "Historic Site Assessment Supplement, "

c) Historic and current survey records review, d) Visual inspections and a "walkdown."

A review of the 10CFR50.75(g)(1) database report and historical files shows a documented history of the Southwest Site Storage Area as a radioactive materials storage area. Examples of some of the major events are provided below.

a) Plant Incident Report (PIR) 80-37 reported the discovery of three (3) discrete sources of elevated activity on the Southeast Site Storage area in March 1980, along with other areas around the site.

The three (3) discrete sources were identified within adjacent Survey Units 9520-0001 and 9520-0002.

The elevated areas were removed upon detection according to the.report.

Revision 0 3

SUBSURFACE AREA ASSOCIATED WITH THE SOUTHWEST SITE STORAGE AREA SURVEY UNIT 9807-0000

.RELEASE RECORD b) Health Physics surveys performed in 1983 and 1985 document the discovery of radioactive material (strainers, bolts, wood pallets, sections of pipe, etc.) on the peninsula.

The 1985 survey documents the discovery of contaminated dirt under a pallet.

c) Condition Report (CR) 05-0314: Documents the discovery of excavation spoils, intended for backfill, above the radiological criteria for use as backfill. These spoils were likely located in Survey Units 9520-0003 and 9520-0004, based on a review of the documentation. According to the CR closure documentation, the affected spoils were removed and packaged for disposal. Follow-up survey and sampling was performed and the results were below established action levels.

A review of the "Initial and Supplemental Characterization Reports" as well as the previous "Classification Basis Summaries" was performed.

Survey Unit 9807-0000 was originally part of subsurface Survey Unit 9805-0000, which was initially designated as Class C during the development of the LTP.

The source documents, the "Connecticut Yankee Haddam Neck Characterization Report" and "Initial Classification for Survey Areas at Connecticut Yankee", were incorporated by reference in LTP revision 0 (references 2-2 and 277 respectively). The second source document justified a Class C designation for those areas for which there was historical evidence of contamination above the Derived Concentration Guideline Levels (DCGLs -

refer to Section 2 for definition and description of DCGL), but for which recent surveys had shown that decontamination efforts had occurred and that the radiological conditions were expected to be below the DCGLs. Additional justification for a Class C designation based on survey and sampling data was provided as another reference to the LTP by the "Haddam Neck Plant Historical Site Assessment Supplement".

However, in March of 2006, Co-60 and Cs-137 were identified in subsurface soils in sufficient quantities to warrant radiological remediation. Radiological remediation was performed in July 2006. A new Class 1 survey unit, Survey Unit 9520-0004, and a new subsurface unit, Survey Unit 9807-0000, were established to bound the area of remediation.

Remedial action was performed in July 2006.

Although Co-60 has been identified in the past, Cs-137 was the only radionuclide with the potential to exceed the screening criteria following the remedial action.

Statistical quantities (mean, median and standard deviation) from the 2006 remedial action survey are provided in Table 1.

Revision 0 4

Revision 0 4

SUBSURFACE AREA ASSOCIATED WITH THE SOUTHWEST SITE STORAGE AREA SURVEY UNIT 9807-0000 RELEASE RECORD Minimum Observed Concentration (pCi/g):

-1.79E-03 Maximum Observed Concentration (pCi/g):

2.24E-02 Mean (pCi/g):

6.84E-03 Median (pCi/g):

3.69E-03 Standard Deviation (pCi/g):

8.39E-03 The FSS Engineer performed a visual inspection and walk-down during September 2006 to assess the physical condition of the survey unit, evaluate access points, and travel paths and identify potentially hazardous conditions.

This survey area is affected by existing groundwater (reference CY memo ISC 06-024) which will be a source of dose from residual radioactivity, as discussed in Section 3 under the Data Quality Objectives.

Based upon the results of radiological surveys performed over six years of restoration and the 2006 remedial action survey, it was concluded that there was a probability for residual radioactivity in concentrations less than the DCGLs, justifying a final survey unit classification of Class B (refer to Section 3). Note, due to the size of the survey unit, the sample to area frequency far exceeds the frequency requirement for Class A survey units of one sample every 500 m2 as specified by LTP Section 5.7.3.2.2.

3.

DATA QUALITY OBJECTIVES (DQO)

FSS design and planning used the Data Quality Objective (DQO) process as described by the LTP, Procedure RPM 5.1-11, "Preparation of Final Status Survey Plan, " and the "Multi-Agency Radiation Survey and Site Investigation Manual" (MARSSIM). A summary of the main features of the DQO process are provided herein.

The DQO process incorporated hypothesis testing and probabilistic sampling distributions to control decision errors during data analysis. Hypothesis testing is a process based on the scientific method that compares a baseline condition to an alternate condition. The baseline condition is technically known as the null hypothesis. Hypothesis testing rests on the premise that the null hypothesis is true and that sufficient evidence must be provided for rejection. In designing the survey plan, the underlying assumption, or null hypothesis was that residual activity in the survey unit exceeded the release criteria. Rejection of the null hypothesis would indicate that residual activity within the survey unit does not exceed the release criteria. Therefore, the survey unit does satisfy the primary objective of the FSS plan.

The primary objective of the FSS plan was to demonstrate that the level of residual radioactivity in Survey Unit 9807-0000 did not exceed the release Revision 0 5

Revision 0 5

SUBSURFACE AREA ASSOCIATED WITH THE SOUTHWEST SITE STORAGE AREA SURVEY UNIT 9807-0000 RELEASE RECORD criteria specified in the LTP and that the potential dose from residual radioactivity is As Low As Reasonably Achievable (ALARA).

A fundamental precursor to survey design is to establish a relationship between the release criteria and some measurable quantity. This is done through the development of DCGLs. The DCGLs represent average levels of radioactivity above background levels and are presented in terms of surface or mass activity concentrations. Chapter 6 of the LTP describes in detail the modeling used to develop the DCGLs for soil (called Base Case Soil DCGL), existing groundwater radioactivity and future groundwater radioactivity that will be contributed by building basements and footings.

The DCGLs presented in Chapter 6 of the LTP were developed for exposures from three (3) components, that is, residual radioactivity in soil, existing groundwater radioactivity, and future groundwater radioactivity from the burial of concrete foundations or footings from site buildings containing residual radioactivity.

Equation 1 shows the mathematical relationship between the three (3) components and the total dose.

Equation I HTotal =Hsoil + HExistingGW + HFutureGW The total dose under the LTP criteria is twenty-five (25) mrem/yr TEDE from all three (3) components.

The allowable total dose under the Connecticut Department of Environmental Protection (CTDEP) radiological remediation standard for CY is nineteen (19) mremryr TEDE. To satisfy both the LTP and CY CTDEP criteria, the dose from soil must be reduced when using the existing and future groundwater dose values discussed above.

This survey area is affected by existing groundwater (reference CY memo ISC 06-024).

Therefore, the dose contribution from existing groundwater is bounded by two (2) mrem/yr TEDE.

This survey unit is not considered impacted by future groundwater radioactive contamination, as there are no buried concrete foundations or footings containing residual radioactive material within the groundwater saturated zone in the area (reference CY memo ISC 06-024). The dose contribution from future groundwater, the third dose component is, therefore, zero (0) mrem/yr TEDE.

Equation 2 19 mrem/yrTotal = 17 mrem/yrsoil + 2 mrem/yrExisting GW+ 0 mrem/yrFutureGw Revision 0 6

SUBSURFACE AREA ASSOCIATED WITH THE SOUTHWEST SITE STORAGE AREA SURVEY UNIT 9807-0000 RELEASE RECORD The allowable dose for soil in this survey unit is seventeen (17) mrem/yr TEDE as shown by Equation 2 above.

The concentration of residual radioactivity resulting in seventeen (17) mrem/yr TEDE is designated as the Operational DCGL, and has been established for the radionuclides of concern as provided in Table 2.

iia.:"t**

,p_* i-ti 16, U.G?.4,,-z!*

H-3 4.12E+02 2.80E3+02 1.65E+01 C-14 5.66E+00 3.85E+00 2.26E-01 Mn-54 1.74E+01 1.18E+01 6.96E-01 Fe-55 2.74E+04 1.86E+04 1.1 OE+03 Co-60 3.81E+00 2.59E+00 1.52E-01 Ni-63 7.23E+02 4.92E+02 2.89E+01 Sr-90 1.55E+00 1.05E+00 6.20E-02 Nb-94 7.12E+00 4.84E+00 2.85E-01 Tc-99 1.26E+01 8.57E+00 5.04E-01 Ag-108mn 7.14E+00 4.86E+00 2.86E-01 Cs-134 4.67E+00 3.18E+00 1.87E-01 Cs-137 7.91E+00 5.38E+00 3.16E-01 Eu-152 1.01E+01 6.87E+00 4.04E-01 Eu-154 9.29E+00 6.32E+00 3.72E-01 Eu-155 3.92E+02 2.67E+02 1.57E+01 Pu-238 2.96E+01 2.01E+01 1.18E+00 Pu-239/240 2.67E+01 1.82E+01 1.07E+00 Pu-241 8.70E+02 5.92E+02 3.48E+01 Am-241 "

2.5 8E+O1 1.75E+01 1.03E+00 Cm-243/244 2.90E+O1 1.97E+01 1.16E+00 (1) Bold indicates those radionuclides considered to be Hard-to-Detect (HTD)

(2) The Base Case Soil DCGLs for soil are specified by the LTP in Chapter 6 and are equivalent to 25 mrem/yr TEDE (3) The Operational DCGL is equivalent to 17 mrem/yr TEDE (4) The required MDC is equivalent to I mrem/yr TEDE (5) Americium-241 can be analyzed by gamma and alpha spectroscopy and is considered to be Easy to Detect (ETD); the preferred result is the alpha spectroscopy's when both analyses are performed Revision 0 7

SUBSURFACE AREA ASSOCIATED WITH THE SOUTHWEST SITE STORAGE AREA SURVEY UNIT 9807-0000 RELEASE RECORD Another important facet of the DQO process is to identify the radionuclides of concern and determine the concentration variability.

Soil samples were collected in 2006 during the remedial action survey.

Cs-137 was the only gamma emitting radionuclide reported in concentrations with the potential for exceeding the screening criteria. The remedial action survey data were used for the survey design and are provided in Table 1.

Instrument DQOs included a verification of the ability of the survey instrument to detect the radiation(s) of interest relative to the DCGL. Survey instrument response checks were required prior to issue and after the instrument had been used. Control and accountability of survey instruments was required to assure the quality and prevent the loss of data.

As part of the DQOs applied to laboratory processes, analysis results were reported as actual 'calculated results. Results reported as less than Minimum Detectable Concentration (MDC) were not accepted for FSS. Sample report summaries included unique sample identification, analytical

method, radionuclide, result, and uncertainty.to two (2) standard deviations, laboratory data qualifiers, units, and the required and observed MDC.
4.

SURVEY DESIGN The level of effort associated with planning a survey is based on the complexity of the survey and nature of the hazards. Guidance for preparing FSS plans is provided in Procedure RPM 5.1-11, "Preparation of Final Status SurVey Plans". The FSS plan uses an integrated sample design that combines scanning surveys and sampling which can be either random or biased.

The DQO process determined that Cs-137 would be the radionuclide of concern in Survey Unit 9807-0000 (refer to Section 3). Other radionuclides identified during this FSS would be evaluated to ensure adequate survey design.

Surrogate DCGLs were not required for this survey unit via screening under LTP Section 5.4.7.2, "Gross Activity DCGLs". Radionuclide screening or de-selection is a process where an individual radionuclide or aggregates may be considered insignificant and eliminated from the FSS.

The criteria for de-selection are concentrations less than 5% for individual radionuclides and less than 10% for aggregates.

The Elevated Measurement Comparison (EMC) did not apply to this survey unit since it is a Class B area and discrete, elevated areas of contamnination were not expected.

The Sign Test was selected as the non-parametric statistical test. The use of the Sign Test did not require the selection or use of a background reference area, which simplified survey design and implementation.

This approach was conservative since it included background Cs-137 as part of the sample set.

Revision 0 8

SUBSURFACE AREA ASSOCIATED WITH THE SOUTHWEST SITE STORAGE AREA SURVEY UNIT 9807-0000 RELEASE RECORD The number of soil samples for FSS was determined in accordance with the LTP. The Lower Bound of the Gray Region (LBGR) was set in accordance with Procedure RPM 5.1-11 to 5.36 to maintain the relative shift (A/o) in the range of 1 and 3. The resulting Adjusted Relative Shift was 2.0. A Prospective Power Curve Was generated using COMPASS, a software package developed under the sponsorship of the United States Nuclear Regulatory Commission (USNRC) for implementation of the MARSSIM in support of the decommissioning license termination rule (10 CFR 20, Subpart E). The result of the COMPASS computer run showed adequate power for the survey design.

The survey design specified twenty-five (25) core soil samples for non-parametric statistical testing.

The grid pattern and locations of the soil samples were determined using Visual Sample Plan (VSP) in accordance with Procedure RPM 5.1-14, "Identifying, and Marking Surface Sample Locations f.or Final Status Survey."

Visual Sample Plan was created by Pacific Northwest National Laboratory (PNNL) for the United States Department of Energy. A systematic triangular grid pattern with a random starting point was selected for sample design, which is appropriate for a Class B area.

Judgmental sampling was not detennined to be necessary by the DQOs, based on the short distance between the area that was subjected to remedial action and FSS sample location 9807-0000-012F.

Sample locations were identified using AutoCAD-LT, a commercially available plotting software package with coordinates consistent with the Connecticut State Plane System. These coordinates were integrated with a GPS to locate sample locations in the field. Sample Measurement Locations for the design are listed with the GPS coordinates in Table 3.

Tal 3-SmpeMasu ýenehtjn t

Loatonsi c~iit4d PS`Codiae Desi~giation2 Nlnhin'ies 9807-0000-001F 235632.88 669753.10 9807-0000-002F 23563,2.88 669784.48 9807-0000-003F 235632.88 669815.87 9807-0000-004F 235605.70 669737.40 9807-0000-005F 235605.70 669768.79 9807-0000-006F 235605.70 669800.18 9807-0000-007F 235605.70 669831.56 9807-0000-008F 235605.70 669862.95 9807-0000-009F 235578.52 669721.71 9807-0000-01 OF 235578.52 669753.10 9807-0000-01 IF 235578.52 669784.48 Revision 0 9

Revision 0 9

SUBSURFACE AREA ASSOCIATED WITH THE SOUTHWEST SITE STORAGE AREA SURVEY UNIT 9807-0000 RELEASE RECORD Table 0-02 235u5 6

58 9807-0000-012F 235578.52 669815.87 9807-0000-013F 235578.52 669847.25 9807-0000-014F 235578.52 669878.64 9807-0000-015F 235551.34 669737.40 9807-0000-016F 235551.34 669768.79 9807-0000-017F 235551.34 669800.18 9807-0000-018F 235551.34 669831.56 9807-0000-019F 235551.34 669862.95 9807-0000-020F 235551.34 669894.33 9807-0000-021F 235524.15 669784.48 9807-0000-022F 235524.1.5 669815.87 9807-0000-023F 235524.15 669847.25 9807-0000-024F 235524.15 669878.64 9807-0000-025F 235496.97 669862.95 Procedure RPM 5.1-11 specifies that 5% of the samples are required to be selected for HTD analysis. Three (3) soil samples, or about 10% of the number of samples that would be used for non-parametric statistical testing were randomly selected for HTD radionuclide analysis using the Microsoft Excel "RANDBETWEEN" function. Each sample was sent off-site for a full suite analysis of the HTD radionuclides specified in the LTP, Table 2-12, "Radionuclides Potentially Present at Haddam Neck Plant" and as provided in Table 2.

The implementation of quality control measures as referenced by Procedure RPM 5.1-24, "Split Sample Assessment for Final Status Survey," included the collection of three (3) soil samples for "split sample" analysis by the off-site laboratory. These locations were selected randomly using the Microsoft Excel "RANDBETWEEN" function. The number of quality control soil samples was about 10% of twenty-five (25) samples.

The LTP does not require scanning for elevated areas of radioactivity in subsurface survey units.

For this Class B survey unit, the "Investigation Level" for soil sample measurement results are those levels specified in LTP, Table 5-8.

Table 4 provides a synopsis of the survey design.

Revision 0 10 Revision 0 10

SUBSURFACE AREA ASSOCIATED WITH THE SOUTHWEST SITE STORAGE AREA SURVEY UNIT 9807-0000 RELEASE RECORD

~F~tiii j%

-a BsisI.2.

Survey Unit Land Area 1,983 m-Based on AutoCAD-LT 25 Number of Measurements (25 systematic grid)

Based on LTP 5.7.3.2.2 0)

Grid Spacing 9.6 m Based on triangular grid Administratively set to achieve Operational DCGL 5.3 8 pCi/g Cs-137 17 mrem/yr TEDE (2)

The Operational DCGL meets Soil Investigation Level 5.38 pCi/g Cs-137 the LTP criteria for a Class B survey unit (1) Due to the size of the survey unit, the sample to area frequency far exceeds the frequency requirement for Class A survey units of one sample every 500 m2 as specified by LTP Section 5.7.3.2.2 (2) The allowable dose for soil in this survey unit is 17 mrem/yr TEDE as the bounding dose from existing and future groundwater has been established based on field data (reference CY memo ISC 06-024)

5.

SURVEY IMPLEMENTATION FSS field activities were conducted under Work Plan and Inspection Record (WP&IR) 2006-0038. The WP&IR package included a detailed FSS plan, job safety analysis, job planning checklist and related procedures for reference.

Daily briefings were conducted to discuss the expectations for job performance and the safety aspects of the survey. The "Daily Survey Journal" was used to document field activities and other information pertaining to the FSS.

Measurement locations were identified in North American Datum (NAD) 1927 coordinates using GPS coordinates; sample locations were identified and marked with a surveyor's flag or paint for identification.

Twenty-five (25) subsurface soil samples were collected and packaged in accordance with Haddam Neck Plant (HNP) Procedure RPM 5.1-3, "Collection of Sample Media for Final Status Survey" and FSS design.

Samples were controlled, transported, stored, and transferred to the off-site laboratory using Chain-of-Custody (COC) protocol in accordance with Procedure RPM 5.1-5, "Chain of Custody for Final Status Survey Samples."

Three (3) samples (9807-0000-003F, 9807-0000-008F and 9807-0000-013F) were randomly selected for HTD radionuclide analysis.

The implementation of survey specific quality control measures included the collection of three (3) samples (9807-0000-012F, 9807-0000-018F and 9807-0000-024F) for "split sample" analysis.

Revision 0 I1I Revision 0 11

SUBSURFACE AREA ASSOCIATED WITH THE SOUTHWEST SITE STORAGE AREA SURVEY UNIT 9807-0000 RELEASE RECORD

6.

SURVEY RESULTS All field survey activities were conducted between September 13, 2006 and September 21, 2006.

The off-site laboratory employed for the radiological analyses of samples was General Engineering Laboratories, LLC. The laboratory analyzed the twenty-five (25) samples collected for non-parametric statistical testing, and the associated field splits using gamma spectroscopy.

Gamma spectroscopy analysis was performed to the required MDCs. Gamma spectroscopy results identified some radionuclides meeting the accepted criteria for detection (i.e., a result greater than two standard deviations uncertainty). However, Cs-137 was the only radionuclide reported in concentrations exceeding the de-selection criteria.

Cs-137 was identified in eight (8) of the twenty-five (25) samples collected for non-parametric statistical testing.

Cs-137 was the primary radionuclide confirming the DQOs. The mean of the gamma spectroscopic analysis results for the sample population indicated that Cs-137 was present at levels lower than the concentrations of Cs-137 found in soil at off-site locations within the vicinity of the HNP as presented in the Health Physics TSD BCY-HP-0063.

A summary of the twenty-five (25) samples collected for non-parametric statistical testing results is provided in Table 5.

K: Table 5 Sumar of Soil ampl Results for the StatisticAl Sample Population Sampl Number

=tCs-137" Fraction of the S

a m p* le N u m b er.

. *....<..., o..,..:...* :.::*

......'=.

(pci/g)

Op.erational DCGE.,L 9807-0000-001 F

-7.91E-03 0.000 9807-0000-002F

-2.76E-02 0.000 9807-0000-003F 4.02E-02 0.007 9807-0000-004F

-1.26E-03 0.000 9807-0000-005F 1.87E-02 0.003 9807-0000-006F

-8.34E-03 0.000 9807-0000-007F

-1.54E-02 0.000 9807-0000-008F

-1.36E-02 0.000 9807-0000-009F 3.30E-02 0.006 9807-0000-01 OF 2.86E-02 0.005 9807-0000-01 IF

-2.32E-02 0.000 9807-0000-012F 4.36E-02 0.008 9807-0000-013F

-2.5 1E-03 0.000 9807-0000-014F 8.18E-03 0.002 Revision I 12 Revision I 12

SUBSURFACE AREA ASSOCIATED WITH THE SOUTHWEST SITE STORAGE AREA SURVEY UNIT 9807-0000 RELEASE RECORD

    • ,Table,_54* Summary ofSoil Sample.Resul ts for the Statistical Sample....*,:.

Population_

Sample

,,*ei* Cs137 F,

Fraction.of the.

P.......

/g)'

Operational DCGL."

9807-0000-015F 1.29E-02 0.002 9807-0000-016F 6.01E-03 0.001 9807-0000-017F 3.34E-02 0.006 9807-0000-018F 2.39E-03 0.000 9807-0000-019F

-3.24E-04 0.000 9807-0000-020F 3.53E-02 0.007 9807-0000-021 F 0.OOE+00 0.000 9807-0000-022F 2.88E-02 0.005 9807-0000-023F 2.56E-02 0.005 9807-0000-024F 1.18E-02 0.002 9807-0000-025F 3.50E+00 0.651 (1) The Operational DCGL from Table 2 is 5.38 pCi/g for Cs-137 to achieve seventeen (17) mrem/yr TEDE The off-site laboratory also processed three (3) samples for HTD analysis as required by the sample plan.

The requested analyses included alpha spectroscopy, gas proportional counting, and liquid scintillation depending on the radionuclide and the measurement method. All analyses met the required MDC.

As previously stated in Section 4 of this report, the criteria for de-selection of a radionuclide is a concentration that is less than 5% of the Operational DCGL for individual radionuclides and less than 10% of the Operational DCGLs for aggregates. H-3 and Am-241 were the only HTDs identified above the accepted criteria for detection (i.e., a result greater than two standard deviations uncertainty). The off-site laboratory prepared and reanalyzed two (2) of the three (3) original samples for H-3 at HNP's request; and performed H-3 analysis on five (5) other samples bordering the two (2) sample locations. The results of all seven (7) samples were all less than the accepted criteria for detection. The highest result for Am-241 was about 4% of the Operational DCGL.

_~.....fab le"'8" -Hard-to-DetectSample.Ressu.is Sam.ple

.Am-241 Fraction of Ope.atin.al MDCGL 9807-0000-003F 7.13E-01 0.041 9807-0000-008F 5.32E-02 0.003 9807-0000-013F 9.35E-02 0.005 (I) The Operational DCGL from Table 2 is 17.5 pCi/g for Am-241 to achieve 17 mrem/yr TEDE Revision I

.13 Revision I 13

SUBSURFACE AREA ASSOCIATED WITH THE SOUTHWEST SITE STORAGE AREA SURVEY UNIT 9807-0000 RELEASE RECORD

7.

QUALITY CONTROL The off-site laboratory processed the split samples and performed gamma spectroscopy analysis.

Ten percent (10%) of the samples were selected for analysis, which exceeds the 5% minimum required by the LTP. The data were evaluated using USNRC acceptance criteria specified in Inspection Procedure 84750 as detailed in HNP Procedure RPM 5.1-24, "Split Sample Assessment for Final Status Survey". Cs-137 was not detected in sufficient quantities in the field split results at the three (3) locations to evaluate in accordance with procedure. Evaluation using the reported results for K-40 resulted in acceptable agreement between the field split results at these locations.

The sample analysis vendor, General Engineering Laboratories, LLC, maintains quality control and quality assurance plans as part of normal operation. Refer to for data and data quality analysis results.

8.

INVESTIGATIONS AND RESULTS No investigations were performed.

9.

REMEDIATION AND RESULTS Remedial action was performed in July 2006.

Although Co-60 has been identified in the past, Cs-137 was the only radionuclide with the potential to exceed the screening criteria following the remedial action. Health Physics TSD BCY-HP-0078, "ALARA Evaluation of Soil Remediation in Support of Final Status Survey, " has determined that remediation beyond that required to meet the release criteria is unnecessary and that the remaining residual radioactivity in soil was ALARA.

10.

CHANGES FROM THE FINAL STATUS SURVEY PLAN No changes were made to the FSS plan.

11.

DATA QUALITY ASSESSMENT (DQA)

The DQO sample design and data were reviewed in accordance with Procedure RPM 5.1-23, "Data Quality Assessment, " for completeness and consistency.

The sampling design had adequate power as indicated by the Retrospective Power Curve. The Sign Test was performed on the data and compared to the original assumptions of the DQOs. The evaluation of the Sign Test results demonstrates that the survey unit passes the unrestricted release criteria, thus, the null hypothesis is rejected.

Documentation was complete and legible. Surveys and sample collection were consistent with the DQOs and were sufficient to. ensure that the survey unit was properly designated as Class B.

Revision 0 14 Revision 0 14

SUBSURFACE AREA ASSOCIATED WITH THE SOUTHWEST SITE STORAGE AREA SURVEY UNIT 9807-0000 RELEASE RECORD The preliminary data review consisted of calculating basic statistical quantities (e.g., mean, median, standard deviation). The mean and median values are well below the Operational DCGL. Also, the retrospective power curve shows that a sufficient number of samples were collected to achieve the desired power.

Therefore, the survey unit meets the unrestricted release criteria with adequate power as required by the DQOs.

For Cs-137, the range of the data, about five (5) standard deviations, indicated some variation, mainly as a result of one (1) sample that is higher in concentration than the rest of the data set. The difference between the mean and median was about 20% of the standard deviation which indicates some skewness in the data. The data was represented graphically through posting plots, a frequency plot, and a quantile plot.

The frequency plot indicates significant positive skewness due to one (1) sample as confirmed by the calculated skew of 4.99.

All data, assessments, and graphical representations are provided in Attachment 3.

12.

ANOMALIES No anomalies were noted.

13.

CONCLUSION Survey Unit 9807-0000 has met the final DQOs of the FSS plan. The ALARA criteria for soils as specified in Chapter 4 of the LTP were achieved. Elevated Measurement Comparison was not required.

Cs-137 was used for statistical testing to determine the adequacy of the survey unit for FSS.

The sample data passed the Sign Test. The null hypothesis was rejected.

The Retrospective Power Curve generated using COMPASS shows adequate power was achieved. The survey unit is properly designated as Class B.

The dose contribution from soil is less than 1 mrem/yr TEDE based on the average concentration of the samples used for non-parametric statistical sampling.

This survey area is affected by existing groundwater (reference CY memo ISC 06-024); therefore the dose contribution from existing groundwater is bounded at two (2) mrem/yr TEDE.

This survey unit is not considered impacted by future groundwater radioactive contamination, as there are no underground structures, systems or components containing residual radioactive material within the groundwater saturated zone in the area (reference CY memo ISC 06-024); therefore, the dose contribution from future groundwater is zero (0) mrem/yr TEDE.

Revision 0 15 Revision 0 15

SUBSURFACE AREA ASSOCIATED WITH THE SOUTHWEST SITE STORAGE AREA SURVEY UNIT 9807-0000 RELEASE RECORD The average total dose from residual radioactivity in this survey unit, including exposures from the three (3) components as described in Section 3, that is, residual radioactivity in soil, existing groundwater radioactivity, and future groundwater radioactivity from the burial of concrete foundations or footings from site buildings containing residual radioactivity, will not exceed

.3 mrem/yr TEDE.

Therefore, Survey Unit 9807-0000 is acceptable for unrestricted release.

14.

ATTACHMENTS 14.1 Attachment 1 - Figures 14.2 Attachment 2 - Laboratory Results 14.4 Attachment 3 - DQA Results Revision I 16 Revision 1 16

SUBSURFACE AREA ASSOCIATED WITH THE SOUTHWEST SITE STORAGE AREA SURVEY UNIT 9807-0000 RELEASE RECORD ATTACHMENT 1 (FIGURES)

j-CONNECT7CUT RIVER-r Connecticut Yankee Atomic Power Company Date By Figure 1 Site Map With Reference To Survey Unit 980 7-0000 November 2006 J I

Q

{-t-.-_.

7

/

/4 7- //,6

__/

-I'a

\\ /

7-------

Ill 1-2 17 i -L C,!

/

14 (3 -7 I-L 19

.,24 0

12.5 25 IFeet Legend A-20

/-

/

= Sample Point

~1~

I 7--

4 ____

~23 9----

22 Connecticut Yankee Atomic Power Company Survey Unit 9807-0000 Final Status Survey Design

-0.01 0.01

-0.02 Lqgend

-0.03 0.

-0.03 12.5 25 F.t

-0.01

-0.01

-0.01 0.04

. Notes Reported Concentrations in pCi/g 0.02 O0 0.01

-0.02

-0.01 0.03 0.03 0.03 0.03 0.01 0.03 0.0.1 Connecticut Yankee Atomic Power Company Survey Unit 9807-0000 Final Status Survey Cs-13 7 Posting Plot

SUBSURFACE AREA ASSOCIATED WITH THE SOUTHWEST SITE STORAGE AREA SURVEY UNIT 9807-0000 RELEASE RECORD ATTACHMENT 2 (LABORATORY DATA)

General Narrative 1

General Narrative for Connecticut Yankee Atomic Power Co.

Work Order: 172275 SDG: MSR#06-1282 October 04, 2006 Laboratory Identification:

General Engineering Laboratories, LLC 2040 Savage Road Charleston, South Carolina 29407 (843) 556-8171 Summary Sample receipt The samples arrived at General Engineering Laboratories, LLC, Charleston, South Carolina on September 21, 2006 for analysis. Shipping container temperatures were checked, documented, and within specifications. The samples were delivered with proper chain of custody documentation and signatures. All sample containers arrived without any visible signs of tampering or breakage.

Sample Identification The laboratory received the following samples:

Laboratory Identification 172275001 172275002 172275003 172275004 172275005 172275006 172275007 172275008 172275009 172275010 172275011 Sample Description 9807-0000-001F 9807-0000-002F 9807-0000-003F 9807-0000-004F 9807-0000-005F 9807-0000-006F 9807-0000-007F 9807-0000-008F 9807-0000-009F 9807-0000-010F 9807-0000-01 iF 2.

172275012 9807-0000-012F 172275013 9807-0000-01 2FS 172275014 9807-0000-013F 172275015 9807-0000-014F 172275016 9807-0000-0 15F 172275017 9807-0000-01 6F 172275018 9807-0000-017F 172275019 9807-0000-018F 172275020 9807-0000-018FS 172275021 9807-0000-019F 172275022 9907-0000-02OF 172275023 9807-0000-021iF 172275024 9807-0000-022F 172275025 9807-0000-023F 172275026 9807-0000-024F 172275027 9807-0000-024FS 172275028 9807-0000-025F Items of Note There are no items to note.

Case Narrative Sample analyses were conducted using methodology as outlined in General Engineering Laboratories (GEL) Standard Operating Procedures. Any technical or administrative problems during analysis, data review, and reduction are contained 'in the analytical case narratives in the enclosed data package.

Analytical Request Twenty-five soil samples were analyzed for FSSGAM. Three soil samples were analyzed for FSSALL.

Data Packag~e The enclosed data package contains the following sections: General Narrative, Chain of Custody and Supporting Documentation, Data Review Qualifier Definitions, and data from the following fractions: Radiochemistry.

I certify that this data package is in compliance with the SOW, both technically and for completeness, for other than the conditions detailed above. Release of the data contained in this hard copy data package has been authorized by the Laboratory Manager or a designee, as verified by the following signature.

Cheryl Jones Project Manager 3

List of current GEL Certifications as of 04 October 2006 State Certification Alaska UST-062 Arizona AZ0668 Arkansas 88-0651 CLIA 42D0904046 California 01151CA Colorado GenEngLabs Connecticut PH-0169 Dept. of Navy NFESC 413 EPA WG-15J FloridaINELAP E87156 Georgia E87156 (FIJNELAP)

Hawaii N/A Idaho N/A Illinois 200029 Indiana C-SC-01 Kansas E-10332 Kentucky 90129 Louisiana 03046 Maryland

.270 Massachusetts M-SCO12 Michigan 9903 Nevada SC12 New Jersey SCO02 New Mexico FL NELAP E87156 New York 11501 North Carolina 233 North Carolina Drinking W 45709 North Dakota R-158 Oklahoma 9904 Pennsylvania 68-00485 South Carolina 10120001/I 0585001/10120002 Tennessee 02934 Texas TX213-2006A Texas NELAP T104704235-06-TX U.S. Dept. of Agriculture S-52597 US Army Corps of Engineer N/A Utah 8037697376 GEL Vermont VT87156 Virginia 00151 Washington C1641 4,

Chain of Custody and Supporting Documentation 5

Health Physics Procedure GPP-GGGR-R5104-003-Attachment B-CY-001 Major Connecticut Yankee Atomic Power Company Chain of Custody Form No. 2006-568 362 Injun Hollow Road, East Hampton, CT 06424 860-267-2556 Project Name: Haddam Neck Decommissioning Analyses Requested Lab Use Only Contact Name & Phone:

Comments:

Jack McCarthy 860-267-3924 Media Sample Container

__Code Type Size-Analytical Lab (Name, City, State):

Code

&Type General Engineering Laboratories Code 2040 Savage Road Charleston, SC 29407 ATT: Cheryl Jones (843-556-8171)

Priority: E] 30 D. Z 14 D. [] 7 D.

Other:

X

<CIO

_.*-2C

/

Sample Designation Date Time a

Comment, Preservation Lab Sample lD 9807-0000-001 F 91O416-6' 1141P TS C

BP X_

9807-0000-00;I Itq TS C

BP X

9807-0000-003 F

/ ýr7 TS C

BP

->,t 2_

9807-0000-0004/

OR, /5,23 TS C

BP 9807-0000-0 0$5E 105 TS C

BP 9807-0000-0 No F

&*/.1P 1 105 TS C

BP 9807-0000-Opr 1 WnI, j2p.53 TS C

BP 9807-0000-Oc V=

C*W ýL j

\\

5 TS C

BP 9807-0000-0 A V*

?O TS C

BP 9807-0000-0-4,0 qJ14100 I 4 S' TS C

BP 9807-0000-0 0\\ WL*-Qý 4{ c)

TS C

BP P_

NOTES: PO #: 002332 MSR #: &4:/Zi

,. Z LTP QA Dl Radwaste QA

[1 Non QA Samples Shipped Via:

Internal Container M Fed Ex Temp.: _* Deg. C El UPS El Hand Custody Seale ?

  • ~

Y0

1) Relinquished y

Date/Time 2)'I.c eivr By D te/Time Custody Seal Intact?

3Y0.0 W

VA 0

76-1 E] Other

3) Relinquished y

Date/Time

4) Received B; Date/Time BillofLading#_Y N

Bill of Lading #

5) Relinquished By Date/Time
6) Received By Date/Time

Health Physics Procedure GPP-GGGR-R5104-003-Attachment B-CY-001 Major Connecticut Yankee Atomic Power Company Chain of Custody Form No. 2006-569 362 Injun Hollow Road, East Hampton, CT 06424 860-267-2556 Project Name: Haddam Neck Decommissioning Analyses Requested Lab Use Only Contact Name & Phone:

Comments:

Jack McCarthy 860-267-3924 Media Sample Container Code Type Size-Analytical Lab (Name, City, State):

Code

&Type General Engineering Laboratories Code 2040 Savage Road Charleston, SC 29407 ATT: Cheryl Jones (843-556-8171)

Priority: 0 30 D. N 14 D. 717 D.

4 Other:

Sample Designation Date Time Comment, Preservation Lab Sample ID 9807-0000-0 j v

TS C

BP Vnu

-,74d 00140 9807-0000-0 q I Lj.,P C)9 TS C

BP V

o_

9807-0000-0 q.14.G 40, TS C

BP X

9807-0000-0 tLk -

0%

", 060 e.,

TS C

BP 9807-0000-0 VdO o'lf-p C.q,

, TS C

BP 9807-0000-0 11 6,0 c

tav-TS C

BP 9807-0000-0 \\'t=

Q1-t 046 TS C

BP 9807-0000-0

\\--F

\\

f-TS C

BP 9807-0000-0 \\

_S a.1 r-TS C

BP 9807-0000-0 \\0,'F 0tt',6-O, vOz TS C

BP 9807-0000-0o

-m-V 1905

,QC26 TS C

BP I_

NOTES: PO #: 002332 MSR #: o0

-1Z o LTP QA

[

Radwaste QA 0

Non QA Samples Shipped Via:

Internal Container Z Fed Ex Temp.: __ Deg, C EU[S D Hand Custody Sealel

1) Relinquished By Date/Time
2) e ev Date/Time Custody Seal Intact?

___L16 9§/Q 0 n9 o

El Other

3) Relinquished By Date/Time
4) keceived 3y Date/Time YOl NO]

Bill of Lading #

5) Relinquished By Date/Time
6) Received By Date/Time

Health Physics Procedure GPP-GGGR-R5104-003-Attachment B-CY-001 Major Connecticut Yankee Atomic Power Company Chain of Custody Form No. 2006-570 362 Injun Hollow Road, East Hampton, CT 06424 860-267-2556 Project Name: Haddam Neck Decommissioning Analyses Requested Lab Use Only Contact Name & Phone:

Comments:

Jack McCarthy 860-267-3924 Media Sample Container Code Type Size-Analytical Lab (Name, City, State):

Code

&Type AnalyicalCode General Engineering Laboratories 2040 Savage Road Charleston, SC 29407 ATT: Cheryl Jones (843-556-8171)

Priority: 1 30 D. Z 14 D. ZI 7 D.

Other:

Sample Designation Date Time

4.

1 Comment, Preservation Lab Sample D) 9807-0000-0'ZiI q-l 3j

<9 f'6 TS C

BP 9807-0000-0 ogm r,. -

q --11-o(.

os-*

TS C

BP

?C_

9807-0000-0 z:

j, q-t-6<I',

l5--

TS C

BP

-)

9807-0000-0.AI q-ý")

14o',*30 j*4"j TS C

BP 9807-0000-0

_V-O(9 s*)

TS C

BP

-GC5WE g.Q5 ;7~

C? 10606 1

NOTES: PO #: 002332 MSR#: or)

LTP QA E] Radwaste QA LI Non QA Samples Shipped Via:

Internal Container Z Fed Ex Temp.: __ Deg. C 0uPs El Hand Custody Sealed?

1) Relinquished By Date/Time
2) Reivecfv

.!ate/Time El-Other Custody Sentact?

3) Relinquished By Date/Time
4) Received byK Date/Time BillofLadig___YON___

Bill of Lading #

5) Relinquished By Date/Time
6) Received By Date/Time

Connecticut Yankee Statement of Work for Analytical Lab Services

.CY-ISC-SOW-001 Figure 1. Sample Check-in List Date/Time Received:

- 1 O()'0c SDG#:

Work Order Number:______________________

Shipping Cdntainerfl:."

t4

_-_2-_.

C"

. hain of Custody# av.*

5AO k

l

.'ciO

" o tQ_ V 7e-d e_ -

.vw' ".q.

.-b C & " Z " *

1.

Custody Seals orffshipping container intact?..

-Yes t ]No [

A

2.

Custody Seals dated and. signed?

Yes"[ I No [ ].A/l/4

3.

Chain-of-Custody record sent?

Yes

  • .NO 4".

Cooler temperature I I

5.

Vermiculite/packing materials is:

Wet [P Dry II, ]iiJ/

6.'

Number of samples in shipping container:

7.

Sample holding times exceeded?

Yes[

No.y4

  • 8. Samples have:

//tape

-hazard labels custody seals appropriate sample labels

9. Samples are:

_4 1 good condition leaking

-broken

" have air bubbles

10.

Were any.anomalies identified in sample receipt?

Yes[] No,1 11..

.Description of anomalies (include sample numbers):

Data Review Qualifier Definitions 10

Data Review Qualifier Definitions Qualifier Explanation A quality control analyte recovery is outside of specified acceptance criteria Analyte is a surrogate compound Result is less than value reported a

Result is greater than value reported RPD of sample and duplicate evaluated using +/-RL. Concentrations are cSX the RL A

The TIC is a suspected aldol-condensation product Target analyte was detected in the associated blank B

Metals-Either presence of analyte detected in the associated blank, or MDL/IDL a sample value a PQL BD Results are either below the MDC or tracer recovery is low C

Analyte has been confirmed by GC/MS analysis D

Results are reported from a diluted aliquot of the sample d

5-day BOD-The 2:1 depletion requirement was not met for this sample E

Organics-Concentration of the target analyte exceeds the instrument calibration range E

Metals-%difference of sample and SD is

>10%.

Sample concentration must meet flagging criteria H

Analytical holding time was exceeded h

Preparation or preservation holding time was exceeded J

Value is estimated N

Metals-The Matrix spike sample recovery is not within specified control limits N

Organics-Presumptive evidence based on mass spectral library search to make a tentative identification of the analyte (TIC). Quantitation is based on nearest internal standard response factor N/A Spike recovery limits do not apply.

Sample concentration exceeds spike concentration by 4X or more ND Analyte concentration is not detected above the reporting limit UI Gamma Spectroscopy-Uncertain identification X

Consult Case Narrative, Data Summary package, or Project Manager concerning this qualifier Y

QC Samples were not spiked with this compound Z

Paint Filter Test-Particulates passed through the filter, however no free liquids were observed.

11

RADIOLOGICAL ANALYSIS 12

Radiochemistry Case Narrative Connecticut Yankee Atomic Power Co. (YANK)

Work Order 172275 Method/Analysis Information Product:

Alphaspec Am241, Cm, Solid ALL FSS Analytical Method:

DOE EML HASL-300, Am-05-RC Modified Prep Method:

Dry Soil Prep GL-RAD-A-021 Method:

Analytical Batch Number:

Prep Batch Number:

Dry Soil Prep GL-RAD-A-021 Batch Number:

Ash Soil Prep Dry Soil Prep 572120 571426 571421 Sample ID 172275003 172275008 172275014 1201191303 1201191304 1201191305 1201191306 Client ID 9807-0000-003F 9807-0000-008F 9807-0000-013F Method Blank (MB) 172114001(9530-0001-008F) Sample Duplicate (DUP) 172114001(9530-0001-008F) Matrix Spike (MS)

Laboratory Control Sample (LCS)

SOP Reference Procedure for preparation, analysis and reporting of analytical data are controlled by General Engineering Laboratories, LLC as Standard Operating Procedure (SOP). The data discussed in this narrative has been analyzed in accordance with GL-RAD-A-01 1 REV# 14.

Calibration Information:

Calibration Information All initial and continuing calibration requirements have been met.

Standards Information Standard solution(s) for these analyses are NIST traceable and used before the expiration date(s).

Sample Geometry All counting sources were prepared in the same geometry as the calibration standards.

13

Quality Control (QC) Information:

Blank Information The blank volume is representative of the sample volume in this batch.

Designated QC The following sample was used for QC: 172114001 (9530-0001-008F).

QC Information All of the QC samples met the required acceptance limits.

Technical Information:

Holding Time All sample procedures for this sample set were performed within the required holding time.

Preparation Information All preparation criteria have been met for these analyses.

Sample Re-prep/Re-analysis None of the samples in this sample set required reprep or reanalysis.

Miscellaneous Information:

NCR Documentation Nonconformance reports are generated to document any procedural anomalies that may deviate from referenced SOP or contractual documents. A nonconformance report (NCR) was not generated for this SDG.

Manual Integration No manual integrations were performed on data in this batch.

Additional Comments Additional comments were not required for this sample set.

Qualifier information Manual qualifiers were not required.

Method/Analysis Information 14

Product:

Alphaspec Pu, Solid-ALL FSS DOE EML HASL-300, Pu-I -RC Modified Analytical Method:

Prep Method:

Dry Soil Prep GL-RAD-A-021 Method:

Analytical Batch Number:

Prep Batch Number:

Dry Soil Prep GL-RAD-A-021 Batch Number:

Ash Soil Prep Dry Soil Prep 572121 571426 571421 Sample ID 172275003 172275008 172275014 1201191307 1201191308 1201191309 1201191310 Client ID 9807-0000-003F 9807-0000-008F 9807-0000-013F Method Blank (MB) 172114001(9530-0001-008F) Sample Duplicate (DUP) 172114001(9530-0001-008F) Matrix Spike (MS)

Laboratory Control Sample (LCS)

SOP Reference Procedure for preparation, analysis and reporting of analytical data are controlled by General Engineering Laboratories, LLC as Standard Operating Procedure (SOP). The data discussed in this narrative has been analyzed in accordance with GL-RAD-A-0 11 REV# 14.

Calibration Information:

Calibration Information All initial and continuing calibration requirements have been met.

Standards Information Standard solution(s) for these analyses are NIST traceable and used before the expiration date(s).

Sample Geometry All counting sources were prepared in the same geometry as the calibration standards.

Oualitv Control (OC) Information:

Blank Information The blank volume is representative of the sample volume in this batch.

Designated QC The following sample was used for QC: 172114001 (9530-0001-008F).

QC Information All of the QC samples met the required acceptance limits.

15

Technical Information:

Holding Time All sample procedures for this sample set were performed within the required holding time.

Preparation Information All preparation criteria have been met for these analyses.

Sample Re-prep/Re-analysis None of the samples in this sample set required reprep or reanalysis.

Miscellaneous Information:

NCR Documentation Nonconformance reports are generated to document any procedural anomalies that may deviate from referenced SOP or contractual documents. A nonconformance report (NCR) was not generated for this SDG.

Manual Integration No manual integrations were performed on data in this batch.

Additional Comments Additional comments were not required for this sample set.

Qualifier information Manual qualifiers were not required.

Method/Analysis Information Product:

Liquid Scint Pu241, Solid-ALL FSS DOE EML HASL-300, Pu-I I-RC Modified Analytical Method:

Prep Method:

Dry Soil Prep GL-RAD-A-021 Method:

Analytical Batch Number:

Prep Batch Number:

Dry Soil Prep GL-RAD-A-021 Batch Number:

Ash Soil Prep Dry Soil Prep 572122 571426 571421 16

Sample ID Client ID 172275003 9807-0000-003F 172275008 9807-0000-008F 172275014 9807-0000-013F 1201191311 Method Blank (MB) 1201191312 172114001(9530-0001-008F) Sample Duplicate (DUP) 1201191313 172114001(9530-0001-008F) Matrix Spike (MS) 1201191314 Laboratory Control Sample (LCS)

SOP Reference Pr ocedure for preparation, analysis and reporting of analytical data are controlled by General Engineering Laboratories, LLC as Standard Operating Procedure (SOP). The data discussed in this narrative has been analyzed in accordance with GL-RAD-A-035 REV# 8.

Calibration Information:

Calibration Information All initial and continuing calibration requirements have been met.

Standards Information Standard solution(s) for these analyses are NIST traceable and used before the expiration date(s).

Sample Geometry All counting sources were prepared in the same geometry as the calibration standards.

Quality Control (0C) Information:

Blank Information The blank volume is representative of the sample volume in this batch.

Designated QC The following sample was used for QC: 172114001 (9530-0001-008F).

QC Information All of the QC samples met.the required acceptance limits.

Technical Information:

Holding Time All sample procedures for this sample set were performed within the required holding time.

Preparation Information All preparation criteria have been met for these analyses.

Sample Re-prep/Re-analysis None of the samples in this sample set required reprep or reanalysis.

Miscellaneous Information:

NCR Documentation 17

Nonconformance reports are generated to document any procedural anomalies that may deviate from referenced SOP or contractual documents. A nonconformance report (NCR) was not generated for this SDG.

Manual Integration No manual integrations were performed on data in this batch.

Additional Comments Additional comments were not required for this sample set.

Oualifier information Manual qualifiers were not required.

Method/Analysis Information

.Product:

Analytical Method:

Prep Method:

Analytical Batch Number:

Prep Batch Number:

Gamma,Solid-FSS GAM & ALL FSS 226 Ingrowth Waived EML HASL 300, 4.5.2.3 Dry Soil Prep 574335 571421 18

Sample ID 172275001 172275002 172275003 172275004 172275005 172275006 172275007 172275008 172275009 172275010 172275011 172275012 172275013 172275014 172275015 172275016 172275017 172275018 172275019 172275020 1201196536 1201196537 1201196538 ClientID 9807-0000-001F 9807-0000-002F 9807-0000-003F 9807-0000-004F 9807-0000-005F 9807-0000-006F 9807-0000-007F 9807-0000-008F 9807-0000-009F 9807-0000-01OF 9807-0000-01 IF 9807-0000-012F 9807-0000-012FS 9807-0000-013F 9807-0000-014F 9807-0000-015F 9807-0000-016F 9807-0000-017F 9807-0000-018F 9807-0000-018FS Method Blank (MB) 172275001(9807-0000-00IF) Sample Duplicate (DUP)

Laboratory Control Sample (LCS)

SOP Reference Procedure for preparation, analysis and reporting of analytical data are controlled by General Engineering Laboratories, LLC as Standard Operating Procedure (SOP). The data discussed in this narrative has been analyzed in accordance with GL-RAD-A-013 REV# 12.

Calibration Information:

Calibration Information All initial and continuing calibration requirements have been met.

Standards Information Standard solution(s) for these analyses are NIST traceable and used before the expiration date(s).

Sample Geometry All counting sources were prepared in the same geometry as the calibration standards.

Quality Control (OC) Information:

Blank Information The blank volume is representative of the sample volume in this batch.

Designated QC The following sample was used for QC: 172275001 (9807-0000-OOIF).

19

QC Information All of the QC samples met the required acceptance limits.

Technical Information:

Holding Time All sample procedures for this sample set were performed within the required holding time.

Preparation Information All preparation criteria have been met for these analyses.

Sample Re-prep/Re-analysis None of the samples in this sample set required reprep or reanalysis.

Miscellaneous Information:

NCR Documentation Nonconformance reports are generated to document any procedural anomalies that may deviate from referenced SOP or contractual documents. A nonconformance report (NCR) was not generated for this SDG.

Additional Comments Additional comments were not required for this sample set.

Qualifier information Qualifier Reason Analyte Cesium-137 Sample 172275013 UT5 U'

Data rejected due to high peak-width.

Data rejected due to interference.

Cesium-134 172275017 Europium-155 Actinium-228 172275008 172275013 172275002 Ui Data rejected due to low abundance.

Cesium-134 172275003 172275006 172275007 172275008 172275012 172275015 172275018 1201196537 20

Method/Analysis Information Product:

Analytical Method:

Prep Method:

Analytical Batch Number:

Prep Batch Number:

Sample ID 172275021 172275022 172275023 172275024 172275025 172275026 172275027 172275028 1201196539 1201196540 1201196541 Gamma,Solid-FSS GAM & ALL FSS 226 Ingrowth Waived EML HASL 300, 4.5.2.3 Dry Soil Prep 574336

.571423 Client ID 9807-0000-019F 9807-0000-020F 9807-0000-021F 9807-0000-022F 9807-0000-023F 9807-0000-024F 9807-0000-024FS 9807-0000-025F Method Blank (MB) 172275028(9807-0000-025F) Sample Duplicate (DUP)

Laboratory Control Sample (LCS)

SOP Reference Procedure for preparation, analysis and reporting of analytical data are controlled by General Engineering Laboratories, LLC as Standard Operating Procedure (SOP). The data discussed in this narrative has been analyzed in accordance with GL-RAD-A-013 REV# 12.

Calibration Information:

Calibration Information All initial and continuing calibration requirements have been met.

Standards Information Standard solution(s) for these analyses are NIST traceable and used before the expiration date(s).

Sample Geometry All counting sources were prepared in the same geometry as the calibration standards.

Quality Control (0C) Information:

Blank Information The blank volume is representative of the samplevolume in this batch.

21

Designated QC The following sample was used for QC: 172275028 (9807-0000-025F).

QC Information Refer to Non-Conformance Report.

Technical Information:

Holding Time All sample procedures for this sample set were performed within the required holding time.

Preparation Information All preparation criteria have been met for these analyses.

Sample Re-prep/Re-analysis None of the samples in this sample set required reprep or reanalysis.

Miscellaneous Information:

NCR Documentation Nonconformance reports are generated to document any procedural anomalies that may deviate from referenced SOP or contractual documents. The following NCR was generated for this SDG:

NCR 368031 was generated due to Failed RPD for DUP. 1. Failed RPD for DUP: The relative percent difference (172275028 and 120119654) for K-40 and Pb-212 did not meet the duplication criteria. 1.

K-40 and Pb-212 are naturally occurring nuclides. All other nuclides meet within the duplication criteria. Reporting results.

Additional Comments Additional comments were not required for this sample set..

Oualifier information Qualifier Reason Analyte Sample UI Data rejected due to high peak-width.

Cesium-137 172275023 UI Data rejected due to interference.

Europium-155 172275023 UI Data rejected due to low abundance.

Cesium-134 172275021 172275022 172275024 172275025 1201196540 Method/Analysis Information 22

Product:

GFPC, Sr9O, solid-ALL FSS Analytical Method:

EPA 905.0 Modified Prep Method:

Ash Soil Prep Dry Soil Prep GL-RAD-A-021 Method:

Dry Soil Prep Analytical Batch Number:

572301 Prep Batch Number:

571426 Dry Soil Prep GL-RAD-A-021 Batch Number:

571421 Sample ID Client ID 172275003 9807-0000-003F 172275008 9807-0000-008F 172275014 9807-0000-01 3F 1201191723 Method Blank (MB) 1201191724 172275003(9807-0000-003F) Sample Duplicate (DUP) 1201191725 172275003(9807-0000-003F) Matrix Spike (MS) 1201191726 Laboratory Control Sample (LCS)

SOP Reference Procedure for preparation, analysis and reporting of analytical data are controlled by General Engineering Laboratories, LLC as Standard Operating Procedure (SOP). The data discussed in this narrative has been analyzed in accordance with GL-RAD-A-004 REV# 10.

Calibration Information:

Calibration Information All initial and continuing calibration requirements have been met.

Standards Information Standard solution(s) for these analyses are NIST traceable and used before the expiration date(s).

Sample Geometry All counting sources were prepared in the same geometry as the calibration standards.

Oualitv Control (OC) Information:

Blank Information The blank volume is representative of the sample volume in this batch.

Designated QC The following sample was used for QC: 172275003 (9807-0000-003F).

23

QC Information All of the QC samples met the required acceptance limits.

Technical Information:

Holding Time All sample procedures for this sample set were performed within the required holding time.

Preparation Information All preparation criteria have been met for these analyses.

Sample Re-prep/Re-analysis None of the samples in this sample set required reprep or reanalysis.

Chemical Recoveries All chemical recoveries meet the required acceptance limits for this sample set.

Miscellaneous Information:

NCR Documentation Nonconformance reports are generated to document any procedural anomalies that may deviate from referenced SOP or contractual documents. A nonconformance report (NCR) was not generated for this SDG.

Additional Comments Additional comments were not required for this sample set.

Oualifier information Manual qualifiers were not required.

Method/Analysis Information Product:

Liquid Scint Tc99, Solid-ALL FSS Analytical Method:

Analytical Batch Number:

Sample liD 172275003 172275008 172275014 1201190771 1201190772 1201190773 1201190774 DOE EML HASL-300, Tc-02-RC Modified 571877 Client ID 9807-0000-003F 9807-0000-OOSF 9807-0000-013F Method Blank (MB) 172275003(9807-0000-003F) Sample Duplicate (DUP) 172275003(9807-0000-003F) Matrix Spike (MS)

Laboratory Control Sample (LCS) 24

SOP Reference Procedure for preparation, analysis and reporting of analytical data are controlled by General Engineering Laboratories, LLC as Standard Operating Procedure (SOP). The data discussed in this narrative has been analyzed in accordance with GL-RAD-A-005 REV# 13.

Calibration Information:

Calibration Information All initial and continuing calibration requirements have been met.

Standards Information Standard solution(s) for these analyses are NIST traceable and used before the expiration date(s).

Sample Geometry All counting sources were prepared in the same geometry as the calibration standards.

Quality Control (0C) Information:

Blank Information The blank volume is representative of the sample volume in this batch.

Designated QC The following sample was used for QC: 172275003 (9807-0000-003F).

QC Information All of the QC samples met the required acceptance limits.

Technical Information:

Holding Time All sample procedures for this sample set were performed within the required holding time.

Preparation Information All preparation criteria have been met for these analyses.

Sample Re-prep/Re-analysis None of the samples in this sample set required reprep or reanalysis.

Miscellaneous Information:

NCR Documentation Nonconformance reports are generated to document any procedural anomalies that may deviate from referenced SOP or contractual documents. A nonconformance report (NCR) was not generated for this SDG.

Additional Comments Additional comments were not required for this sample set.

25

Qualifier information Manual qualifiers were not required.

Method/Analysis Information Product:

Liquid Scint Fe55, Solid-ALL FSS DOE RESL Fe-1, Modified Analytical Method:

Prep Method:

Dry Soil Prep GL-RAD-A-021 Method:

Analytical Batch Number:

Prep Batch Number:

Dry Soil Prep GL-RAD-A-021 Batch Number:

Ash Soil Prep Dry Soil Prep 571874 571426 571421 Sample ID 172275003 172275008 172275014 1201190757 1201190758 1201190759 1201190760 Client ID 9807-0000-003F 9807-0000-008F 9807-0000-013F Method Blank (MB) 172275008(9807-0000-008F) Sample Duplicate (DUP) 172275008(9807-0000-008F) Matrix Spike (MS)

Laboratory Control Sample (LCS)

SOP Reference Procedure for preparation, analysis and reporting of analytical data are controlled by General Engineering Laboratories, LLC as Standard Operating Procedure (SOP). The data discussed in this narrative has been analyzed in accordance with GL-RAD-A-040 REV# 3.

Calibration Information:

Calibration Information All initial and continuing calibration requirements have been met.

Standards Information Standard solution(s) for these analyses are NIST traceable and used before the expiration date(s).

Sample Geometry All counting sources were prepared in the same geometry as the calibration standards.

Quality Control (QC) Information:

Blank Information 26

The blank volume is representative of the sample volume in this batch.

Designated QC The following sample was used for QC: 172275008 (9807-0000-008F).

QC Information All of the QC samples met the required acceptance limits.

Technical Information:

Holding Time All sample procedures for this sample set were performed within the required holding time.

Preparation Information All preparation criteria have been met for these analyses.

Sample Re-prep/Re-analysis None of the samples in this sample set required reprep or reanalysis.

Miscellaneous Information:

NCR Documentation Nonconformance reports are generated to document any procedural anomalies that may deviate from referenced SOP or contractual documents. A nonconformance report (NCR) was not generated for this SDG.

Additional Comments Additional comments were not required for this sample set.

Gualifier information Manual qualifiers were not required.

Method/Analysis Information Product:

Liquid Scint Ni63, Solid-ALL FSS

  • Analytical Method:

DOE RESL Ni-1, Modified Prep Method:

Ash Soil Prep Dry Soil Prep GL-RAD-A-021 Method:

Dry Soil Prep Analytical Batch Number:

571876 Prep Batch Number:

571426 Dry Soil Prep GL-RAD-A-021 Batch Number:

571421 27

Sample ED 172275003 172275008 172275014 1201190767 1201190768 1201190769 1201190770 Client ID 9807-0000-003F 9807-0000-008F 9807-0000-013F Method Blank (MB) 172275014(9807-0000-013F) Sample Duplicate (DUP) 172275014(9807-0000-013F) Matrix Spike (MS)

Laboratory Control Sample (LCS)

SOP Reference Procedure for preparation, analysis and reporting of analytical data are controlled by General Engineering Laboratories, LLC as Standard Operating Procedure (SOP). The data discussed in this narrative has been analyzed in accordance with GL-RAD-A-022 REV# 8.

Calibration Information:

Calibration Information All initial and continuing calibration requirements have been met.

Standards Information Standard solution(s) for these analyses are NIST traceable and used before the expiration date(s).

Sample Geometry All counting sources were prepared in the same geometry as the calibration standards.

Quality Control (0C) Information:

Blank Information The blank volume is representative of the sample volume in this batch.

Designated QC The following sample was used for QC: 172275014 (9807-0000-013F).

QC Information All of the QC samples met the required acceptance limits.

Technical Information:

Holding Time All sample procedures for this sample set were performed within the required holding time.

Preparation Information All preparation criteria have been met for these analyses.

Sample Re-prep/Re-analysis None of the samples in this sample set required reprep or reanalysis.

Miscellaneous Information:

NCR Documentation 28

Nonconformance reports are generated to document any procedural anomalies that may deviate from referenced SOP or contractual documents. A nonconformance report (NCR) was not generated for this SDG.

Additional Comments Additional comments were not required for this sample set.

Qualifier information Manual qualifiers were not required.

Method/Analysis Information Product:

Analytical Method:

Analytical Batch Number:

Sample ID 172275003 172275008 172275014 1201190793 1201190794 1201190795 1201190796 LSC, Tritium Dist, Solid-HTD2,ALL FSS EPA 906.0 Modified 571884 Client ID 9807-0000-003F 9807-0000-008F 9807-0000-013F Method Blank (MB) 172275003(9807-0000-003F) Sample Duplicate (DUP) 172275003(9807-0000-003F) Matrix Spike (MS)

Laboratory Control Sample (LCS)

SOP Reference Procedure for preparation, analysis and reporting of analytical data are controlled by General Engineering Laboratories, LLC as Standard Operating Procedure (SOP). The data discussed in this narrative has been analyzed in accordance with GL-RAD-A-002 REV# 13.

Calibration Information:

Calibration Information All initial and continuing calibration requirements have been met.

Standards Information Standard solution(s) for these analyses are NIST traceable and used before the expiration date(s).

Sample Geometry All counting sources were prepared in the same geometry as the calibration standards.

29

Quality Control (OC) Information:

Blank Information The blank volume is representative of the sample volume in this batch.

Designated QC The following sample was used for QC: 172275003 (9807-0000-003F).

QC Information All of the QC samples met the required acceptance limits.

Technical Information:

Holding Time All sample procedures for this sample set were performed within the required holding time.

Preparation Information All preparation criteria have been met for these analyses.

Sample Re-prep/Re-analysis None of the samples in this sample set required reprep or reanalysis.

Miscellaneous Information:

NCR Documentation Nonconformance reports are generated to document any procedural anomalies that may deviate from referenced SOP or contractual documents. The following NCR was generated for this SDG:

NCR 365692 was generated due to Container scanning event for custody missed. 1. The analyst did not scan the samples 172275003, 172275008, and 172275014 into the batch prior to analysis, however the samples did remain in their custody at all times. 1. The error has been corrected and the analyst has been instructed on the proper scanning procedures. Reporting results.

Additional Comments Additional comments were not required for this sample set.

Qualifier information Manual qualifiers were not required.

Method/Analysis Information Product:

Liquid Scint C14, Solid AII,FSS Analytical Method:

EPA EERF C-0I Modified Analytical Batch Number:

571880 30

Sample ID Client ID 172275003 9807-0000-003F 172275008 9807-0000-008F 172275014 9807-0000-013F 1201190783 Method Blank (MB) 1201190784 172275003(9807-0000-003F) Sample Duplicate (DUP) 1201190785 172275003(9807-0000-003F) Matrix Spike (MS) 1201190786 Laboratory Control Sample (LCS)

SOP Reference Procedure for preparation, analysis and reporting of analytical data are controlled by General Engineering Laboratories, LLC as Standard Operating Procedure (SOP). The data discussed in this narrative has been analyzed in accordance with GL-RAD-A-003 REV# 8.

Calibration Information:

Calibration Information All initial and continuing calibration requirements have been met.

Standards Infor'mation Standard solution(s) for these analyses are NIST traceable and used before the expiration date(s).

Sample Geometry All counting sources were prepared in the same geometry as the calibration standards.

Quality Control (OQC) Information:

Blank Information The blank volume is representative of the sample volume in this batch.

Designated QC The following sample was used for QC: 172275003 (9807-0000-003F).

QC Information

.All of the QC samples met the required acceptance limits.

Technical Information:

Holding Time All sample procedures for this sample set were performed within the required holding time.

Preparation Information All preparation criteria have been met for these analyses.

Sample Re-prep/Re-analysis None of the samples in this sample set required reprep or reanalysis.

Miscellaneous Information:

NCR Documentation 31

Nonconformance reports are generated to document any procedural anomalies that may deviate from referenced SOP or contractual documents. A nonconformance report (NCR) was not generated for this SDG.

Additional Comments Additional comments were not required for this sample set.

Gualifier information Manual qualifiers were not required.

Certification Statement Where the analytical method has been performed under NELAP certification, the analysis has met all of the requirements of the NELAC standard unless otherwise noted in the analytical case narrative.

Review Validation:

GEL requires all analytical data to be verified by a qualified data validator. In addition, all data designated for CLP or CLP-like packagihg will receive a third level validation upon completion of the data package.

The following data validator verified the information presented in this case narrative:

Reviewer/Date:

32

General Engineering Laboratories Form GEL-NCR Rev. 06105 NCR Report No.:

365692 Revision No.:

COMPANY - WIDE NONCONFORMANCE REPORT Mo.Day Yr.

Division:

Quality Criteria:

Type:

29-SEP-06 Radiochemistry Specifications Process Instrument Type:

Test ! Method:

Matrix Type:

Client Code:

LSC EPA 906.0 Modified Solid YANK Batch ID:

Sample Numbers:

571884 See Below Potentially affected work order(s)(SDG): 172275(MSR#06-1282)

Application Issues:

Container scanning event for custody missed Specification and Requirements NRG Disposition:

Nonconformance

Description:

1. The analyst did not scan the samples 172275003, 172275008, and 172275014 into the batch prior to analysis, however the samples did remain in their custody at all times.
1. The error has been corrected and the analyst has been instructed on the proper scanning procedures. Reporting results.

Originator's Name:

Amy Scott Quality Review:

Data Validator/Group Leader:

Melanie Aycock 01-OCT-06 29-SEP-06 Director:

Page 1 33

General Engineering Laboratories Form GEL-NCR Rev. 06/05 NCR Report No;:

368031 Revision No.:

1 COMPANY-WIDE NONCONFORMANCE REPORT Mo.Day Yr.

Division:

Quality Criteria:

Type:

05-OCT-06 Radiochemistry Specifications Process Instrument Type:

Test / Method:

Matrix Type:

Client Code:

GAMMA SPECTROMETER EML HASL 300, 4.5.2.3 Solid YANK Batch ID:

Sample Numbers:

574336 See Below Potentially affected work order(s)(SDG): 172275(MSR#06-1282),172873(MSR#06-1313),172875(MSR#06-1312),172879(MSR#06-1311)

Application Issues:

Failed RPD for DUP Specification and Requirements NRG Disposition:

Nonconformance

Description:

1. Failed RPD for DUP: The relative percent difference (172275028
1. K-40 and Pb-212 are naturally occurring nuclides. All other nuclides and 120119654) for K-40 and Pb-212 did not meet the duplication meet within the duplication criteria. Reporting results.

criteria.

Originator's Name:

Jimmy Hartley Quality Review:

Data Validator/Group Leader:

05-OCT-06 Director:

Page 1 34

SAMPLE DATA

SUMMARY

35

GENERAL ENGINEERING LABORATORIES, LLC 2040 Savage Road Charleston SC 29407 - (843) 556-8171 - www.gel.com Certificate of Analysis Report for YANKOO Connecticut Yankee Atomic Power Co.

Client SDG: MSR#06-1282 GEL Work Order: 172275 The Qualifiers in this report are defined as follows:

A quality control analyte recovery is outside of specified acceptance criteria Analyte is a surrogate compound U

Analyte was analyzed for, but not detected above the MDL, MDA, or LOD.

UI Gamma Spectroscopy--Uncertain identification ND The analyte concentration is not detected above the detection limit.

The above sample is reported on a dry weight basis except where prohibited by the analytical procedure.

Where the analytical method has been performed under NELAP certification, the analysis has met all of the requirements of the NELAC standard unless qualified on the Certificate of Analysis.

This data report has been prepared and reviewed in accordance with General Engineering Laboratories, LLC standard operating procedures. Please direct any questions to your Project Manager, Cheryl Jones.

Reviewed by 36

GENERAL ENGINEERING LABORATORIES, LLC 2040 Savage Road Charleston SC 29407 - (843) 556-8171 - www.gel.com Certificate of Analysis Company : Connecticut Yankee Atomic Power Address:

362 Injun Hollow Rd East Hampton, Connecticut 06424

Contact:

Mr. Jack McCarthy Project:

Soils PO# 002332 Report Date:

October 5, 2006 Client Sample ID:

9807-0000-00IF Project:

YANK01204 Sample ID:

172275001 Client ID:

YANK001 Matrix:

TS Vol. Recv.:

Collect Date:

13-SEP-06 Receive Date:

21-SEP-06 Collector:

Client Moisture:

16.6%

Parameter Qualifier Result Uncertainty LC TPU MDA Units DF Analyst Date Time Batch Mtd Rad Gamma Spec Analysis Gamma,Solid-FSS GAM & ALL FSS 226 Ingrowth Waived Actinium-228 0.917

+/-0.197 0.0541

+/-0.197 0.119 pCi/g MJH1 10/03/060635 574335 1

Americium-241 U

0.0336

+/-0.0304 0.027 +/-0.0304 0,0556 pCilg Bismuth-212 0.332

+/-0.297 0.136

+/-0.297 0.293 pCi/g Bismuth-214 0.594

+/-0.0918 0.0352 +/-0.0918 0.075 pCi/g Cesium-134 U

0.0178

+/-0.0337 0.0227 +/-0.0337 0.0486 pCi/g Cesium-137 U -0.00791

+/-0.0231 0.0166 +/-0.0231 0.0358 pCi/g

.Cobalt-60 U

-0.032

+/-0.0272 0.0154 +/-0.0272 0.0349 pCilg Europium-152 U

0.00865

+/-0.0526 0.048 +/-0.0526 0.101 pCi/g Europium-154 U -0.00226

+1-0.0668 0.0569 +/-0.0668 0.125 pCi/g Europium-155 U

0.0769

+/-0.0755 0.0429 +/-0.0755 0.0889 pCi/g Lead-212 0.826

+/-0.0631 0.0264 +/-0.0631 0.0549 pCi/g Lead-214 0.596

+/-0.0873 0.0338 +/-0.0873 0.0711 pCi/g Manganese-54 U -0.00108

+/-0.0247 0.0207 +/-0.0247 0.0442 pCi/g Niobium-94 U -0.00289

+/-0.021 0.0177

+/-0.021 0.0378 pCi/g Potassium-40 12.6

+/-0.924 0.140

+/-0.924 0.321 pCi/g Radium-226 0.594

+/-0.0918 0.0352 +/-0.0918 0.075 pCi/g Silver-108m U

0.00205

+/-0.0182 0.0163 +/-0.0182 0.0344 pCi/g Thallium-208 0.288

+/-0.0486 0.0178 +/-0.0486 0.0381 pCi/g The following Prep Methods were performed Method Description Analyst Date Time Prep Batch Dry Soil Prep Dry Soil Prep GL-RAD-A-021 JMBI 09/21/06 1745 571421 The following Analytical Methods were performed Method Description EML HASL 300, 4.5.2.3 Notes:

The Qualifiers in this report are defined as follows:

A quality control analyte recovery is outside of specified acceptance criteria Result is less than value reported 37

GENERAL ENGINEERING LABORATORIES, LLC 2040 Savage Road Charleston SC 29407 - (843) 556-8171 - www.gel.com Certificate of Analysis Company:

Connecticut Yankee Atomic Power Address:

362 Injun Hollow Rd East Hampton, Connecticut 06424 Report Date:

October 5, 2006

Contact:

Mr. Jack McCarthy Project:

Soils PO# 002332 Client Sample ID:

9807-0000-00IF Proiect:

YANK01204 Sample ID:

172275001 Client ID:

YANK001 Vol. Recv.:

Parameter Qualifier Result Uncertainty LC TPU MDA Units DF Analyst Date Time Batch Mtd Result is greater than value reported A

The TIC is a suspected aldol-condensation product B

Target analyte was detected in the associated blank BD Results are either below the MDC or tracer recovery is low C

Analyte has been confirmed by GC/MS analysis D

Results are reported from a diluted aliquot of the sample H

Analytical holding time was exceeded J

Value is estimated N/A Spike recovery limits do not apply. Sample concentration exceeds spike concentration by 4X or more R

Sample results are rejected U

Analyte was analyzed for, but not detected above the MDL, MDA, or LOD.

UI Ganmma Spectroscopy-Uncertain identification X

Consult Case Narrative, Data Summary package, or Project Manager concerning this qualifier Y

QC Samples were not spiked with this compound A

RPD of sample and duplicate evaluated using +/-RL. Concentrations are <5X the RL

-h Preparation or preservation holding time was exceeded The above sample is reported on a dry weight basis.

38

GENERAL ENGINEERING LABORATORIES, LLC 2040 Savage Road Charleston SC 29407 - (843) 556-8171 - www.gel.com Certificate of Analysis Company : Connecticut Yankee Atomic Power Address:

362 Injun Hollow Rd East Hampton, Connecticut 06424

Contact:

Mr. Jack McCarthy Project:

Soils PO# 002332 Report Date: October 5, 2006 Client Sample ID:

Sample ID:

Matrix:

Collect Date:

Receive Date:

Collector:

Iklr;*lIs 9807-0000-002F 172275002 TS 13-SEP-06 2 1-SEP-06 Client 1A QO1 Project:

YANK01204 Client ID:

YANK001 Vol. Recv.:

Parameter Qualifier Result Uncertainty LC TPU MDA Units DF Analyst Date Time Batch Mtd Rad Gamma Spec Analysis Gamma,Sohid-FSS GAM & ALL FSS 226 Ingrowth Waived Actinium-228 UI 0.00

+/-0.199 Americium-241 U

0.0381

+/-0.0369 Bismuth-212 0.434

+/-0.350 Bismuth-214 0.556

+/-0.106 Cesiutn-134 U

0.035

+/-0.0431 Cesiurn-137 U

-0.0276

+/-0.0307 Cobalt-60 U

0.0211

+1-0.0298 Europium-152 LU -0.0121

+/-0.0687 Europium-154 U

0.0712

+/-0.0952 Europium-155 U

0.0585

+/-0.0674 Lead-212 0.740

+/-0.0888 Lead-214 0.618

+/-0.109 Manganese-54 U

-0.0246

+/-0.0275 Niobium-94 U -0.00223

+/-0.0244 Potassium-40 12.6

+/-1.09 Radium-226 0.556

+/-0.106 Silver-108m U

0.00737

+/-0.0234 Thallium-208 0.257

+/-0.0585 0.163 0.0312 0.179 0.0356 0.0301 0.0211 0.0272 0.0491 0.0863 0.0466 0.0283 0.0383 0.0221 0.0214 0.164 0.0356 0.0173 0.0233

+/-0.199

+/-0.0369

+/-0.350

+/-0.106

+/-0.0431

+/-0.0307

+/-0.0298

+/-0.0687

+/-0.0952

+/-0.0674

+/-0.0888

+/-0.109

+/-0.0275

+1-0.0244

+/-1.09

+/-0.106

+/-0.0234

+1-0.0585 0.325 0.0624 0.358 0.0711 0.0601 0.0421 0.0543 0.0981 0.173 0.0931 0.0566 0.0766 0.0441 0.0428 0.327 0.0711 0.0345 0.0465 pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCilg pCi/g pCi/g pCi/g pCi/g MJHI 10/03/060650 574335 1

The following Prep Methods were performed Method Description Analyst Date Time Prep Batch Dry Soil Prep Dry Soil Prep GL-RAD-A-021 JMBI 09/21/06 1745 571421 The following Analytical Methods were performed Method Description I

EMIL HASL 300, 4.5.2.3 Notes:

The Qualifiers in this report are defined as follows:

A quality control analyte recovery is outside of specified acceptance criteria Result is less than value reported 39

GENERAL ENGINEERING LABORATORIES, LLC 2040 Savage Road Charleston SC 29407 - (843) 556-8171 - www.gel.com Certificate of Analysis Company:

Connecticut Yankee Atomic Power Address :

362 Injun Hollow Rd East Hampton, Connecticut 06424 Report Date: October 5, 2006

Contact:

Mr. Jack McCarthy Project:

Soils PO# 002332 Client Sample ID:

9807-0000-002F Project:

YANK01204 Sample ID:

172275002 Client ID:

YANK001 Vol. Recv.:

Parameter Qualifier Result Uncertainty LC TPU MDA Units DF Analyst Date Time Batch Mtd Result is greater than value reported A

The TIC is a suspected aldol-condensation product B

Target analyte was detected in the associated blank BD Results are either below the MDC or tracer recovery is low C

Analyte has been confirmed by GC/MS analysis D

Results are reported from a diluted aliquot of the sample H

Analytical holding time was exceeded J

Value is estimated N/A Spike recovery limits do not apply. Sample concentration exceeds spike concentration by 4X or more R

Sample results are rejected U

Analyte was analyzed for, but not detected above the MDL, MDA, or LOD.

UI Gamma Spectroscopy--Uncertain identification X

Consult Case Narrative, Data Summary package, or Project Manager concerning this qualifier Y

QC Samples were not spiked with this compound A

RPD of sample and duplicate evaluated using +/-RL. Concentrations are <5X the RL h

Preparation or preservation holding time was exceeded The above sample is reported on a dry weight basis.

40

GENERAL ENGINEERING LABORATORIES, LLC 2040 Savage Road Charleston SC 29407 - (843) 556-8171 - www.gel.com Certificate of Analysis Company : Connecticut Yankee Atomic Power Address :

362 Injun Hollow Rd East Hampton, Connecticut 06424

Contact:

Mr. Jack McCarthy Project:

Soils PO# 002332 Report Date:

October 5, 2006 Client Sample ID:

Sample ID:

Matrix:

Collect Date:

Receive Date:

Collector:

lMn i hll-P-9807-0000-003F 172275003 TS 13-SEP-06 21-SEP-06 Client IA 07-Proiect:

YANK01204 Client ID:

YANK001 Vol. Recv.:

Parameter Qualifier Result Uncertainty LC TPU MDA Units DF Analyst Date Time Batch Mtd Rad Alpha Spec Analysis Alphaspec Am241, Cm, Solid ALL FSS Americium-241 Curium-242 U

Curium-243/244 U

0.713 0.00 0.0354

+/-0.277

+/-0.0579

+/-0.080 0.0248 0.00 0.043

+/-0.293

+/-0.0579

+/-0.0801 0.125 0.080 0.161 0.175 0.182 pCilg pCilg pCilg pcilg pCilg Alphaspec Pu, Solid-ALL FSS Plutonium-238 U

-0.0431 4

Plutonium-239/240 U -0.00359 4

Liquid Scint Pu241, Solid-ALL FSS Plutonium-241 U

1.79 Rad Gamma Spec Analysis Gamma,Solid-FSS GAM & ALL FSS 226 Ingrowth Waived Actinium-228 0.743 Americium-241 U

0.014 Bismuth-212 0.547 Bismuth-214 0.558 Cesium-134 U]

0.00 Cesium-137 U

0.0402 Cobalt-60 U

0.0104 Europium-152 U

0.098 Europium-154 U

-0.032 Europium-155 U -0.00541 Lead-212 0.628 Lead-214 0.585 Manganese-54 U -0.00284 Niobium-94 U -0.00174 Potassium-40 13.1 Radium-226 0.558 Silver-108m U

0.0131 Thallium-208 0.247 Rad Gas Flow Proportional Counting GFPC, Sr90, solid-ALL FSS Strontium-90 U -0.00839 Rad Liquid Scintillation Analysis LSC, Tritium Dist, Solid-HTD2,ALL FSS Tritium 32.4

-/-0.0532 0.057 +/-0.0532

/-0.0698 0.0604 +/-0.0698

+/-8.11 6.73

+/-8.12 14.1 pCi/g

+/-0.218 4-0.0362

+/-0.295

+/-0.109

/-0.0386 4/-0.0327

+/-0.0285

+/-0.0702

+/-0.0804

+/-0.0571 F/-0.0808

+/-0.110

+/-0,0262

+/-0.0241

+/-0.962

+/-0.109

+/-0.022 F/-0.0581

+/-0.0152 0.0704 0.0304 0.175 0.0428 0.0286 0.0243 0.0248 0.0562 0.0651 0.0485 0.0384 0.0369 0.0217 0.0204 0.206 0.0428 0.0204 0.0211

+/-0.218

+/-0.0362

+/-0.295

+/-0.109

+/-0.0386

+/-0.0327

+/-0.0285

+/-0.0702

+/-0.0804

+/-0.0571

+/-0.0808

+/-0.110

+/-0.0262

+/-0.0241

+/-0.962

+/-0.109

+/-0.022

+/-0.0581 0.152 0.0626 0.370 0.0901 0.0604 0.0512 0.0536 0.117 0.141 0.100 0.079 0.0775 0.0462 0.0432 0.453 0.0901 0.0427

.0.0447 0.0324 pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCilg pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g TC1 09/28/06 1156 572120 1

TC1 09/28/060935 572121 2

TC1 09/29/06 2230 572122 3

MJHI 10/03/060635 574335 4

KSDI 09/28/06 0957 572301 5

DFA1 09/27/06 1825 571884 6

0.014 +/-0.0152

+/-8.92 5.77

+/-8.93 12.3 pCi/g 41

GENERAL ENGINEERING LABORATORIES, LLC 2040 Savage Road Charleston SC 29407 - (843) 556-8171 - www.gel.com Certificate of Analysis Company:

Connecticut Yankee Atomic Power Address :

362 Injun Hollow Rd East Hampton, Connecticut 06424

Contact:

Mr. Jack McCarthy Project:

Soils PO# 002332.

Report Date: October 5, 2006 Client Sample ID:

Sample lID:

9807-0000-003F 172275003 Project:

YANK01204 Client ID:

YANK001 Vol. Recv.:

Parameter Qualifier Result Rad Liquid Scintillation Analysis Liquid Scint C14, Solid AII, FSS Carbon-14 U

-0.0626 Liquid Scint Fe55, Solid-ALL FSS lron-55 U

-9.41 Liquid Scint Ni63, Solid-ALL FSS Nickel-63 U

2.54 Liquid Scint Tc99, Solid-ALL FSS Technetium-99 U

0.165 Uncertainty LC TPU MDA Units DF Analyst Date Time Batch Mtd

+1-0.105 0.0892

+/-0.105

+/-37.1 26.5

+/-37.1

+/-7.06 5.86

+/-7.06

+/-0.222 0.183

+/-0.222 0.181 55.3 pCi/g pCi/g AXD2 09/25/06 1910 571880 7

MXPI 09/28/06 1737 571874 8

MXP1 09/29/06 1842 571876 9

KXRI 10/02/06 1055 571877 10 12.1 pCi/g 0.374 pCi/g The following Prep Methods were performed Method Description Analyst Date Time Prep Batch Dry Soil Prep Dry Soil Prep GL-RAD-A-021 JMB]

09/21/06 1745 571421 The following Analytical Methods were performed Method Description I

DOE EML HASL-300, Am-05-RC Modified 2

DOE EML HASL-300, Pu-11-RC Modified 3

DOE EML HASL-300, Pu-I 1-RC Modified 4

EML HASL 300, 4.5.2.3 5

EPA 905.0 Modified 6

EPA 906.0 Modified 7

EPA EERF C-01 Modified 8

DOE RESL Fe-1, Modified 9

DOE RESL Ni-l, Modified 10 DOE EML HASL-300, Tc-02-RC Modified Surrogate/Tracer recovery Americium-243 Plutonium-242 Carrier/Tracer Recovery Carrier/Tracer Recovery Carrier/Tracer Recovery Carrier/Tracer Recovery Carrier/Tracer Recovery Alphaspec Am24 1, Cm, Solid ALL Alphaspec Pu, Solid-ALL FSS Liquid Scint Pu241, Solid-ALL FS GFPC, Sr90, solid-ALL FSS Liquid Scint Fe55, Solid-ALL FS Liquid Scint Ni63, Solid-ALL FS Liquid Scint Tc99, Solid-ALL FS Recovery%

94 99 95 92 68 70 63 Acceptable Limits (15%-125%)

(15%-125%)

(25%-125%)

(25%-125%)

(15%-125%)

(25%-125%)

(15%-125%)

42

GENERAL ENGINEERING LABORATORIES, LLC 2040 Savage Road Charleston SC 29407 - (843) 556-8171 - www.gel.corn Certificate of Analysis Company:

Connecticut Yankee Atomic Power Address :

362 Injun Hollow Rd East Hampton, Connecticut 06424 Report Date: October 5, 2006

Contact:

Mr. Jack McCarthy Project:

Soils PO# 002332 Client Sample ID:

9807-0000-003F Project:

YANK01204 Sample ID:

172275003 Client ID:

YANK001 Vol. Recv.:

Parameter Qualifier Result Uncertainty LC TPU MDA Units DF Analyst Date Time Batch Mtd Notes:

The Qualifiers in this report are defined as follows:

A quality control analyte recovery is outside of specified acceptance criteria Result is less than value reported Result is greater than value reported A

The TIC is a suspected aldol-condensation product B

Target analyte was detected in the associated blank BD Results are either below the MDC or tracer recovery is low C

Analyte has been conftrmed by GC/MS analysis D

Results are reported from a diluted aliquot of the sample H

Analytical holding time was exceeded J

Value is estimated N/A Spike recovery limits do not apply. Sample concentration exceeds spike concentration by 4X or more R

Sample results are rejected U

Analyte was analyzed for, but not detected above the MDL, MDA, or LOD.

UI Gamma Spectroscopy--Uncertain identification X

Consult Case Narrative, Data Summary package, or Project Manager concerning this qualifier Y

QC Samples were not spiked with this compound A

RPD of sample and duplicate evaluated using +/-RL. Concentrations are <5X the RL h

Preparation or preservation holding time was exceeded The above sample is reported on a dry weight basis.

43

GENERAL ENGINEERING LABORATORIES, LLC 2040 Savage Road Charleston SC 29407 - (843) 556-8171 - www.gel com Certificate of Analysis Company:

Connecticut Yankee Atomic Power Address 362 Injun Hollow Rd East Hampton, Connecticut 06424

Contact:

Mr. Jack McCarthy Project:

Soils PO# 002332 Report Date: October 5, 2006 Client Sample ID:

Sample ID:

Matrix:

Collect Date:

Receive Date:

Collector:

Moisture:

9807-0000-004F 172275004 TS 13-SEP-06 21 -SEP-06 Client 14.4%

Project:

Client ID:

Vol. Recv.:

YANKIK0 1204 YANK001 Parameter Qualifier Result Uncertainty LC TPU MDA Units DF Analyst Date Time Batch Mtd Rad Ganuna Spec Analysis Gamma,.Solid-FSS GAM & ALL FSS 226 Ingrowth Waived Actinium-228 0.863

+/-0.169 Americium-241 U -0.00206

+/-0.058 Bismuth-212 0.377

+/-0.244 Bismuth-214 0.646

+/-0.0986 Cesium-134 U

0.0312

+/-0.0276 Cesium-137 U -0.00126

+/-0.0161 Cobalt-60 U

0.00622

+1-0.0174 Europium-152 U

0.0205

+/-0.0405

.Europium-154 U -0.00568

+/-0.0572 Europium-155 U

0.0483

+/-0.0558 Lead-212 0.775

+/-0.0787 Lead-214 0.667

+/-0.0933 Manganese-54 U -0.00358

+/-0.0178 Niobium-94 U

0.00439

+/-0.0152 Potassium--40 11.9

.+/-1.04 Radium-226 0.646

+/-0.0986 Silver-108m U

0.0023

+/-0.0131 Thallium-208 0.264

+/-0.0477 0.0462 0.048 0.0985 0.0267 0.018 0.0141 0.0157 0.0365 0.0491 0.0388 0.0259 0.0269 0.015 0.0136 0.141 0.0267 0.0113 0.0123

+/-0.169

+/-0.058

+/-0.244

+/-0.0986

+/-0.0276

+/-0.0161

+/-0.0174

+/-0.0405

+/-0.0572

+/-0.0558

+/-0.0787

+/-0.0933

+/-0.0178

+/-0.0152

+/- 1.04

+/-0.0986

+/-0.0131

+/-0.0477 0.101 0.0992 0.213 0.0568 0.0384 0.0301 0.0344 0.0767 0.106 0.0804 0.0535 0.0566 0.0321 0.0289 0.312 0.0568 0.0241 0.0265 pCi/g pCi/g pCi/g pCi/g pCi/g pCilg pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCilg pCi/g pCi/g pCi/g pCi/g MJHIl 10/03/060640 574335 1

The following Prep Methods were performed Method Description Analyst Date Time Prep Batch Dry Soil Prep Dry Soil Prep GL-RAD-A-021 JMB 1 09/21/06 1745 571421 The following Analytical Methods were performed Method Description I

EML HASL 300, 4.5.2.3 Notes:

The Qualifiers in this report are defined as follows:

A quality control analyte recovery is outside of specified acceptance criteria Result is less than value reported 44

GENERAL ENGINEERING LABORATORIES, LLC 2040 Savage Road Charleston SC 29407 - (843) 556-8171 - www.gel.com Certificate of Analysis Company:

Connecticut Yankee Atomic Power Address:

362 Injun Hollow Rd East Hampton, Connecticut 06424 Report Date: October 5, 2006

Contact:

Mr. Jack McCarthy Project:

Soils PO# 002332 Client Sample ID:

9807-0000-004F Proiect:

YANK01204 Sample ID:

172275004 Client ID:

YANK001 Vol. Recv.:

Parameter Qualifier Result Uncertainty LC TPU MDA Units DF Analyst Date Time Batch Mtd Result is greater than value reported A

The TIC is a suspected aldol-condensation product B

Target analyte was detected in the associated blank BD Results are either below the MDC or tracer recovery is low C

Analyte has been.confirmed by GC/MS analysis D

Results are reported from a diluted aliquot of the sample H

Analytical holding time was exceeded I

Value is estimated N/A Spike recovery limits do not apply. Sample concentration exceeds spike concentration by 4X or more R

Sample results are rejected U

Analyte was analyzed for, but not detected above the MDL, MDA, or LOD.

UI Gamma Spectroscopy-Uncertain identification X

Consult Case Narrative, Data Summary package, or Project Manager concerning this qualifier Y

QC Samples were not spiked with this compound A

RPD of sample and duplicate evaluated using +/-RL. Concentrations are <5X the RL h

Preparation or preservation holding time was exceeded The above sample is reported on a dry weight basis.

45

GENERAL ENGINEERING LABORATORIES, LLC 2040 Savage Road Charleston SC 29407- (843) 556-8171 - www.gel.com Certificate of Analysis Company : Connecticut Yankee Atomic Power Address :

362 Injun Hollow Rd East Hampton, Connecticut 06424

Contact:

Mr. Jack McCarthy Project:

Soils PO# 002332 Report Date: October 5, 2006 Client Sample ID:

Sample ID:

Matrix:

Collect Date:

Receive Date:

Collector:

Moisture:

9807-0000-005F 172275005 TS 14-SEP-06 21-SEP-06 Client 14.5%

Project:

Client ID:

Vol. Recv.:

YANK01204 YANK00l Parameter Qualifier Result Uncertainty LC TPU MDA Units DF Analyst Date Time Batch Mtd Rad Gamma Spec Analysis Gamma,Solid-FSS GAM & ALL FSS 226 Ingrowth Waived Actinium-228 0.678

+/-0.170 Americium-241 U

-0.0294

+/-0.0785 Bismuth-212 0.485

+/-0.254 Bismuth-214 0.598

+/-0.0828 Cesium-134 U

0.0242

+/-0.0336 Cesium-137 U

0.0187

+/-0.0195 Cobalt-60 U

0.00172

+/-0.0209 Europium-152 U

0.00129

+/-0.0502 Europium-154 U

-0.0127

+/-0.0667 Europium-155 U

0.0208.

+/-0.0552 Lead-212 0.747

+/-0.0649 Lead-214 0.625

+/-0.0802 Manganese-54 U

0.0177

+/-0.0212 Niobium-94 U

-0.0084

+/-0.0177 Potassium-40 12.1

+/-0.919 Radium-226 0.598

+/-0.0828 Silver-108m U

0.00158

+/-0.0174 Thallium-208 0.237

+/-0.0404 0.056 0.0727 0.137 0.0305 0.0214 0.0174 0.018 0.0443 0.0559 0.0506 0.0259 0.0331 0.0193 0.0148 0.147 0.0305 0.0151 0.0179

+/-0.170

+/-0.0785

+/-0.254

+/-0.0828

+/-0.0336

+/-0.0195

+/-0.0209

+/-0.0502

+/-0.0667

+/-0.0552

+/-0.0649

+/-0.0802

+/-0.0212

+/-0.0177

+/-0.919

+1-0.0828

+/-0.0174

+/-0.0404 0.121 0.150 0.292 0.0647 0.0455 0.0369 0.0395 0.093 0.121 0.105 0.0539 0.0693 0.0411 0.0316 0.330 0.0647 0.0319 0.0378 pCi/g pCi/g pCilg pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g MJH1 10/03/06 1051 574335 1

The following Prep Methods were performed Method Description Analyst Date Time Prep Batch Dry Soil Prep Dry Soil Prep GL-RAD-A-021 JMBI 09/21/06 1745 571421 The following Analytical Methods were performed Method Description I

EMIL HASL 300, 4.5.2.3 Notes:

The Qualifiers in this report are defined as follows A quality control analyte recovery is outside of specified acceptance criteria Result is less than value reported 46

GENERAL ENGINEERING LABORATORIES, LLC 2040 Savage Road Charleston SC 29407 - (843) 556-8171 - www.gel.com Certificate of Analysis Company Connecticut Yankee Atomic Power Address:

362 Injun Hollow Rd East Hampton, Connecticut 06424 Report Date: October 5, 2006

Contact:

Mr. Jack McCarthy Project:

Soils PO# 002332 Client Sample ID:

9807-0000-005F Project:

YANKO1204 Sample ID:

172275005 Client ID:

YANyK001 Vol. Recv.:

Parameter Qualifier Result Uncertainty LC TPU MDA Units DF Analyst Date Time Batch Mtd Result is greater than value reported A

The TIC is a suspected aldol-condensation product B

Target analyte was detected in the associated blank BD Results are either below the MDC or tracer recovery is low C

Analyte has been confirmed by GC/MS analysis D

Results are reported from a diluted aliquot of the sample H

Analytical holding time was exceeded J

Value is estimated N/A Spike recovery limits do not apply. Sample concentration exceeds spike concentration by 4X or more R

Sample results are rejected U

Analyte was analyzed for, but not detected above the MDL, MDA, or LOD.

UI Gamma Spectroscopy--Uncertain identification X

Consult Case Narrative, Data Summary package, or Project Manager concerning this qualifier Y

QC Samples were not spiked with this compound A

RPD of sample and duplicate evaluated using +/-RL. Concentrations are <5X the RL h

Preparation or preservation holding time was exceeded The above sample is reported on a dry weight basis.

47

GENERAL ENGINEERING LABORATORIES, LLC 2040 Savage Road Charleston SC 29407 - (843) 556-8171 - www.gel.com Certificate of Analysis Company : Connecticut Yankee Atomic Power Address :

362 Injun Hollow Rd East Hampton, Connecticut 06424

Contact:

Mr. Jack McCarthy Project:

Soils PO# 002332 Report Date: October 5, 2006 Client Sample ID:

Sample ID:

Matrix:

Collect Date:

Receive Date:

Collector:

Moisture:

9807-00O-006F 172275006 TS 14-SEP-06 21 -SEP-06 Client 16.3%

Project:

YANK01204 Client ID:

YANKOOI Vol. Recv.:

Parameter Qualifier Result Uncertainty LC TPU MDA Units DF Analyst Date Time Batch Mtd Rad Gamma Spec Analysis Gamma,Solid-FSS GAM & ALL FSS 226 Ingrowth Waived Actinium-228 1.07

+/-0.186 Americium-241 U

0.00123

+/-0.0301 Bismuth-212 0.559

+/-0.281 Bismuth-214 0.661

+/-0.101 Cesium-134 UI 0.00

+/-0.0326 Cesium-137 U -0.00834

+/-0.0233 Cobalt-60 U -0.00223

+/-0.022 Europium-152 U

-0.0377

+1-0.0521 Europium-154 U

0.0272

+/-0.072 Europium-155 U

0.0135

+/-0.0507 Lead-212 0.743

+/-0.0793 Lead-214 0.653

+/-0.0828 Manganese-54 U

0.00649

+/-0.0239 Niobium-94 U

0.0181

+/-0.0214 Potassium-40 12.9

+/-0.976 Radium-226 0.661

+/-0.101 Silver-108m U 0.000501

+/-0.0181 Thallium-208 0.274

+/-0.0451 0.0767

+/-0.186 0.0282 +/-0.0301 0.145

+/-0.281 0.0358

+/-0.101 0.027 +/-0.0326 0.0194 +/-0.0233 0.0184

+/-0.022 0.045 +/-0.0521 0.0639

+/-0.072 0.0466 +/-0.0507 0.0384 +/-0.0793 0.0328 +/-0.0828 0.0205 +/-0.0239 0.0195 +/-0.0214 0.203

+/-0.976 0.0358

+/-0.101 0.016 +/-0.0181 0.0198 +/-0.0451 0.164 0.058 0.311 0.0763 0.0572 0.0414 0.041 0.0949 0.139 0.0962 0.079 0.0691 0.044 0.0414 0.448 0.0763 0.034 0.042 pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g MJH1 10/03/06 1049 574335 1

The following Prep Methods were performed Method Description Analyst Date Time Prep Batch Dry Soil Prep Dry Soil Prep GL-RAD-A-021 JMBI 09/21/06 1745 571421 The following Analytical Methods were performed Method Description EML HASL 300, 4.5.2.3 Notes:

The Qualifiers in this report are defined as follows:

A quality control analyte recovery is outside of specified acceptance criteria Result is less than value reported 48

GENERAL ENGINEERING LABORATORIES, LLC 2040 Savage Road Charleston SC 29407 - (843) 556-8171 - www.gel.com Certificate of Analysis Company:

Connecticut Yankee Atomic Power Address:

362 lnjun Hollow Rd East Hampton, Connecticut 06424 Report Date: October 5, 2006

Contact:

Mr. Jack McCarthy Project:

Soils PO# 002332 Client Sample ID:

9807-0000-006F Project:

YANK01204 Sample ID:

172275006 Client ID:

YANK001 Vol. Recv.:

Parameter Qualifier Result Uncertainty LC TPU MDA Units DF Analyst Date Time Batch Mtd Result is greater than value reported A

The TIC is a suspected aldol-condensation product B

Target analyte was detected in the associated blank BD Results are either below the MDC or tracer recovery is low C

Analyte has been confimned by GC/MS analysis D

Results are reported from a diluted aliquot of the sample H

Analytical holding time was exceeded J

Value is estimated N/A Spike recovery limits do not apply. Sample concentration exceeds spike concentration by 4X or more R

Sample results are rejected U

Analyte was analyzed for, but not detected above the MDL, MDA, or LOD.

UI Gamma Spectroscopy-Uncertain identification X

Consult Case Narrative, Data Summary package, or Project Manager concerning this qualifier Y

QC Samples were not spiked with this compound A

RPD of sample and duplicate evaluated using +/-RL. Concentrations are <5X the RL h

Preparation or preservation holding time was exceeded The above sample is reported on a dry weight basis.

49

GENERAL ENGINEERING LABORATORIES, LLC 2040 Savage Road Charleston SC 29407 - (843) 556-8171 - www.gel.com Certificate of Analysis Company:

Connecticut Yankee Atomic Power Address:

362 Injun Hollow Rd East Hampton, Connecticut 06424

Contact:

Mr. Jack McCarthy Project:

Soils PO# 002332 Report Date:

October 5, 2006 Client Sample ID:

Sample ID:

Matrix:

Collect Date:

Receive Date:

Collector:

Moisture:

9807-0000-007F 172275007 TS 14-SEP-06 21-SEP-06 Client 16.3%

Proiect:

YANKO1204 Client ID:

YANKOOl Vol. Recv.:

Parameter Qualifier Result Uncertainty LC TPU MDA Units DF Analyst Date Time Batch Mtd Rad Gamma Spec Analysis Gamina,Solid-FSS GAM & ALL FSS 226 Ingrowth Waived Actinium-228 1.04

+/-0.231 Americium-241 U

0.0164

+/-0.0391 Bismuth-212 0.619

+/-0.380 Bismuth-214 0.704

+/-0.150 Cesium-134 U1 0.00

+1-0.0551 Cesium-137 U

-0.0154

+/-0.0318 Cobalt-60 U

0.0125

+/-0.0307 Europium-152 U

-0.026

+/-0.0732 Europium-154 U

0.0051

+/-0.100 Europium-155 U

0.0526

+/-0.0654 Lead-212 0.771

+/-0.0987 Lead-214 0.915

+/-0.122 Manganese-54 U

-0.0344

+/-0.0384 Niobium-94 U

0.0132

+/-0.031 Potassium-40 14.7

+/-1.13 Radium-226 0.704

+/-0.150 Silver-108m U

-0.0191

+/-0.0299 Thallium-208 0.300

+/-0.0768 0.0956 0.0342 0.209 0.0501 0.035 0.0259 0.0267 0.0599 0.0842 0.0562 0.0509 0.0416 0.0248 0.0268 0.236 0.0501 0.0221 0.0242

+/-0.231

+/-0.0391

+/-0.380

+/-0.150

+/-0.0551

+/-0.0318

+/-0.0307

+/-0.0732

+/-0.100

+/-0.0654

+/-0.0987

+/-0.122

+/-0.0384

+/-0.031

+/-1.13

+/-0.150

+/-0.0299

+/-0.0768 0.204 0.0705 0.443 0.105 0.0737 0.055 0.0582 0.126 0.181 0.116 0.104 0.0874 0.0529 0.0563 0.520 0.105 0.0464 0.0513 pCi/g pCi/g pCi/g pCi/g pci/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g MJHI 10/03/06 0942 574335 1

The following Prep Methods were performed Method Description Analyst Date Time Prep Batch Dry Soil Prep Dry Soil Prep GL-RAD-A-021 JMB1 09/21/06 1745 571421 The following Analytical Methods were performed Method Description I

EML HASL 300, 4.5.2.3 Notes:

The Qualifiers in this report are defined as follows:

A quality control analyte recovery is outside of specified acceptance criteria Result is less than value reported 50

GENERAL ENGINEERING LABORATORIES, LLC 2040 Savage Road Charleston SC 29407 - (843) 556-8171 - www.gel.com Certificate of Analysis Company:

Connecticut Yankee Atomic Power Address :

362 Injun Hollow Rd East Hampton, Connecticut 06424 Report Date: October 5, 2006

Contact:

Mr. Jack McCarthy Project:

Soils PO# 002332 Client Sample ID:

9807-0000-007F Proiect:

YANK01204 Sample ID:

172275007 ClientID:

YANK00l Vol. Recv.:

Parameter Qualifier Result Uncertainty LC TPU MDA Units DF Analyst Date Time Batch Mtd Result is greater than value reported A

The TIC is a suspected aldol-condensation product B

Target analyte was detected in the associated blank BD Results are either below the MDC or tracer recovery is low C

Analyte has been confirmed by GC/MS analysis D

Results are reported from a diluted aliquot of the sample H

Analytical holding time was exceeded J

Value is estimated N/A Spike recovery limits do not apply. Sample concentration exceeds spike concentration by 4X or more R

Sample results are rejected U

Analyte was analyzed for, but not detected above the MDL, MDA, or LOD.

U1 Gamma Spectroscopy--Uncertain identification X

Consult Case Narrative, Data Summary package, or Project Manager concerning this qualifier Y

QC Samples were not spiked with this compound A

RPD of sample and duplicate evaluated using +/-RL. Concentrations are <5X the RL h

Preparation or preservation holding time was exceeded The above sample is reported on a dry weight basis.

51

GENERAL ENGINEERING LABORATORIES, LLC 2040 Savage Road Charleston SC 29407 - (843) 556-8171 - www.gel.com Certificate of Analysis Company:

Connecticut Yankee Atomic Power Address :

362 Injun Hollow Rd East Hampton, Connecticut 06424

Contact:

Mr. Jack McCarthy Project:

Soils PO# 002332 Report Date: October 5, 2006 Client Sample ID:

Sample ID:

Matrix:

Collect Date:

Receive Date:

Collector:

9807-0000-008F 172275008 TS 14-SEP-06 21-SEP-06 Client Project:

YANK01204 Client ID:

YANK001 Vol. Recv.:

lvlu0s1uIUe:

1990 Parameter Qualifier Result Uncertainty LC TPU MDA Units DF Analyst Date Time Batch Mtd Rad Alpha Spec Analysis Alphaspec Am241, Cm, Solid ALL FSS Americium-241 U

0.0532 Curium-242 U -0.00721 Curium-243/244 U -0.00679 Alphaspec Pu, Solid-ALL FSS Plutonium-238 U

0.0937 Plutonium-239/240 U

0.00832 Liquid Scint Pu241, Solid-ALL FSS Plutonium-241 U

4.23 Rad Gamma Spec Analysis GammaSolid-FSS GAM & ALL FSS 226 Ingrowth Waived Actinium-228 0.976 Americium-241 U

-0.0602 Bismuth-212 0.758 Bismuth-214 0.583 Cesium-134 UI 0.00 Cesium-137 U

-0.0136 Cobalt-60 U

0.00942 Europium-152 U

-0.0506 Europium-154 U

0.0206 Europium-155 UI 0.00 Lead-212 0.855 Lead-214 0.640 Manganese-54 U

0.0129 Niobium-94 U

0.00328 Potassium-40 15.0 Radium-226 0.583 Silver-108m U

0.0147 Thallium-208 0.284 Rad Gas Flow Proportional Counting GFPC, Sr90, solid-ALL FSS Strontium-90 U

0.00217 Rad Liquid Scintillation Analysis

+/-0.0818

+/-0.0141 i-l-0.0133 0.0254 0.027 0.0254

+/-0.082

+/-0.0142

+/-0.0133

+/-0.131 0.0738

+/-0.131

+/-0.079 0.0617

+!-0.079

+/-8.60 7.03

+/-8.61

+/-0.198

+/-0.0632

+/-0.285

+/-0.106

+/-0.0311

+/-0.0191

+/-0.0186

+/-0.0475

+/-0.0594

+/-0.0721

+/-0.088

+/-0.0941

+/-0.0261

+/-0.0155

+/-1.32

+/-0.106

+/-0.016

+/-0.0503 0.0581 0.0478 0.106 0.029 0.0234 0.0156 0.0169 0.0375 0.0529 0.0427 0.0236 0.0296 0.0148 0.0136 0.123 0.029 0:0144 0.0148

+/-0.198

+/-0.0632

+/-0.285

+/-0.106

+/-0.0311

+/-0.0191

+/-0.0186

+/-0.0475

+/-0.0594

+/-0.0721

+/-0.088

+/-0.0941

+/-0.0261

+/-0.0155

+/-1.32

+/-0.106

+/-0.016

+/-0.0503 0.127 0.135 0.127 0.218 0.194 14.8 0.125 0.099 0.229 0.0618 0.0495 0.0335 0.0373 0.0793 0.115 0.0885 0.0492 0.0623 0.0321 0.0293 0.282 0.0618 0.0304 0.0316 0.033 pCi/g pCilg pCi/g pCi/g pCi/g pCi/g pCilg pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCilg pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g TCI 09/28/06 1156 572120 1

TCI 09/28/06 1156 572121 2

TC1 09/29/06 2246 572122 3

MJHIl 10/03/06 0943 574335 4

KSDI 09/28/06 0734 572301 5

DFA1 09/27/06 1841 571884 6

+/-0.017 0.0139

+/-0.017 LSC, Tritium Dist, Solid-HTD2,ALL FSS Tritium 182

+/-16.1 6.41

+/-16.4 13.7 pCi/g 52

GENERAL ENGINEERING LABORATORIES, LLC 2040 Savage Road Charleston SC 29407 - (843) 556-8171 - www.gel.com Certificate of Analysis Company : Connecticut Yankee Atomic Power Address :

362 Injun Hollow Rd East Hampton, Connecticut 06424

Contact:

Mr. Jack McCarthy Project:

Soils PO# 002332 Report Date: October 5, 2006 Client Sample ID:

Sample ID:

9807-0000-008F 172275008 Project:

Client ID:

Vol. Recv.:

YANK01204 YANKO01 Parameter Qualifier Result Rad Liquid Scintillation Analysis Liquid Scint C14, Solid AII, FSS Carbon-14 U

-0.0464 Liquid Scint Fe55, Solid-ALL FSS Iron-55 U

0.774 Liquid Scint Ni63, Solid-ALL FSS Nickel-63 U

-6.65 Liquid Sciti Tc99, Solid-ALL FSS Technetium-99 U

-0.0457 Uncertainty LC TPU MDA Units DF Analyst Date Time Batch Mtd

+/-0.099 0.0838

+/-0.099 0.170 pCi/g pci/g

+/-38.8 27.4

+/-38.8 57.2 AXD2 09/25/06 2023 571880 7

MXPI 09/28/06 1753 571874 8

MXPJ 09/29/06 1929 571876 9

KXRI 10/02/06 1127 571877 10

+/-7.14 6.17

+/-7.14 12.7 pCi/g

+/-0.214 0.180

+/-0.214 0.368 pCi/g The following Prep Methods were performed Method Description Analyst Date Time Prep Batch Dry Soil Prep Dry Soil Prep GL-RAD-A-021 JMB1 09/21/06 1745 571421 The following Analytical Methods were performed Method Description I

DOE EML HASL-300, Am-05-RC Modified 2

DOE EML HASL-300, Pu-II-RC Modified 3

DOE EML HASL-300, Pu-i I-RC Modified 4

EML HASL 300,4.5.2.3 5

EPA 905.0 Modified 6

EPA 906.0 Modified 7

EPA EERF C-01 Modified 8

DOE RESL Fe-1, Modified 9

DOE RESL Ni-l, Modified 10 DOE EML HASL-300, Tc-02-RC Modified Surrogate/Tracer recovery Test Recovery%

Acceptable Limits Americium-243 Plutonium-242 Carrier/Tracer Recovery Carrier/Tracer Recovery Carrier/Tracer Recovery Carrier/Tracer Recovery Carrier/Tracer Recovery Alphaspec Am241, Cm, Solid ALL Alphaspec Pu, Solid-ALL FSS Liquid Scint Pu241, Solid-ALL FE GFPC, Sr90, solid-ALL FSS Liquid Scint Fe55, Solid-ALL FS Liquid Scint Ni63, Solid-ALL FS Liquid Scint Tc99, Solid-ALL FS 82 94 91 83 68 66 63 (15%-125%)

(15%-125%)

(25%-125%)

(25%-125%)

(15%-125%)

(25%- 125%)

(15%-125%)

53

GENERAL ENGINEERING LABORATORIES, LLC 2040 Savage Road Charleston SC 29407 - (843) 556-8171 - www.gel.com Certificate of Analysis Company:

Connecticut Yankee Atomic Power Address :

362 Injun Hollow Rd East Hampton, Connecticut 06424 Report Date: October 5, 2006

Contact:

Mr. Jack McCarthy Project:

Soils PO# 002332 Client Sample ID:

9807-0000-008F Project:

YANK01204 Sample ID:

172275008 Client ID:

YANK001 Vol. Recv.:

Parameter Qualifier Result Uncertainty LC TPU MI)A Units DF Analyst Date Time Batch Mtd Notes:

The Qualifiers in this report are defined as follows:

A quality control analyte recovery is outside of specified acceptance criteria Result is less than value reported Result is greater than value reported A

The TIC is a suspected aldol-condensation product B

Target analyte was detected in the associated blank BD Results are either below the MDC or tracer recovery is low C

Analyte has been confirmed by GC/MS analysis D

Results are reported from a diluted aliquot of the sample H

Analytical holding time was exceeded J

Value is estimated N/A Spike recovery limits do not apply. Sample concentration exceeds spike concentration by 4X or more R

Sample results are rejected U

Analyte was analyzed for, but not detected above the MDL, MDA, or LOD.

UI Gamma Spectroscopy-Uncertain identification X

Consult Case Narrative, Data Summary package, or Project Manager concerning this qualifier Y

QC Samples were not spiked with this compound A

RPD of sample and duplicate evaluated using +/-RL. Concentrations are <5X the RL h

Preparation or preservation holding time was exceeded The above sample is reported on a dry weight basis.

54

GENERAL ENGINEERING LABORATORIES, LLC 2040 Savage Road Charleston SC 29407 - (843) 556-8171 - www.gel.com Certificate of Analysis Company:

Connecticut Yankee Atomic Power Address :

362 Injun Hollow Rd East Hampton, Connecticut 06424.

Contact:

Mr. Jack McCarthy Project:

Soils PO# 002332 Report Date:

October 5, 2006 Client Sample ID:

Sample ID:

Matrix:

Collect Date:

Receive Date:

Collector:

Moisture:

9807-0000-009F 172275009 TS 14-SEP-06 21-SEP-06 Client 14%

Project:

YANK01204 Client ID:

YANK001 Vol. Recv.:

Parameter Qualifier Result Uncertainty LC TPU MDA Units DF Analyst Date Time Batch Mtd Rad Gamma Spec Analysis Gamma,Solid-FSS GAM & ALL FSS 226 Ingrowth Waived Actinium-228 1.04

+/-0.248 Americium-241 U

0.0151

+/-0.045 Bismuth-212 U

0.460

+/-0.476 Bismuth-214 0.642

+/-0.127 Cesium-134 U

0.0541

+/-0.0521 Cesium-137 U

0.033

+/-0.0399

.Cobalt-60 U

0.00639

+/-0.0403 Europium-152 U

-0.119

+/-0.112 Europium-154 U

-0.0098

+/-0.139 Europium-155 U

0.0758

+/-0.0709 Lead-212 0.719

+/-0.126 Lead-214 0.805

+/-0.131 Manganese-54 U -0.00895

+/-0.0334 Niobium-94 U

0.0464

+/-0.0345 Potassium-40 12.8

+/-1.33 Radium-226 0.642

+/-0.127 Silver-108m U

-0.0253

+/-0.027 Thallium-208 0.269

+/-0.0623 0.0903 0.0347 0.232 0.0505 0.0356 0.0297 0.034 0.055 0.0974 0.0579 0.0395 0.0432 0.0278 0.0262 0.260 0.0505 0.0212 0.030

+/-0.248

+/-0.045

+/-0.476

+/-0.127

+/-0.0521

+/-0.0399

+/-0.0403

+/-0.112

+/-0.139

+/-0.0709

+/-0.126

+/-0.131

+/-0.0334

+/-0.0345

+/-1.33

+/-0.127

+/-0.027

+/-0.0623 0.180 0.0694 0.464 0.101 0.0711 0.0593 0.0679 0.110 0.195 0.116 0.079 0.0863 0.0555 0.0525 0.520 0.101 0.0424 0.0599 pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g MJHI 10/03/06 0953 574335 1

The following Prep Methods were performed Method Description Analyst Date Time Prep Batch Dry Soil Prep Dry Soil Prep GL-RAD-A-021 JMBI 09/21/06 1745 571421 The following Analytical Methods were performed Method Description I

EML HASL 300, 4.5.2.3 Notes:

The Qualifiers in this report are defined as follows:

A quality control analyte recovery is outside of specified acceptance criteria Result is less than value reported 55

GENERAL ENGINEERING LABORATORIES, LLC 2040 Savage Road Charleston SC 29407 - (843) 556-8171 - www.gel.com Certificate of Analysis Company:

Connecticut Yankee Atomic Power Address:

362 Injun Hollow Rd East Hampton, Connecticut 06424 Report Date: October 5, 2006

Contact:

Mr. Jack McCarthy Project:

Soils PO# 002332 Client Sample ID:

9807-0000-009F Project:

YANK01204 Sample ID:

172275009 Client ID:

YANK001 Vol. Recv.:

Parameter Qualifier Result Uncertainty LC TPU MDA Units DF Analyst Date Time Batch Mtd Result is greater than value reported A

The TIC is a suspected aldol-condensation product B

Target analyte was detected in the associated blank BD Results are either below the MDC or tracer recovery is low C

Analyte has been confirmed by GC/MS analysis D

Results are reported from a diluted aliquot of the sample H

Analytical holding time was exceeded J

Value is estimated N/A Spike recovery limits do not apply. Sample concentration exceeds spike concentration by 4X or more R

Sample results are rejected U

Analyte was analyzed for, but not detected above the MDL, MDA, or LOD.

UI Gamma Spectroscopy-Uncertain identification X

Consult Case Narrative, Data Summary package, or Project Manager concerning this qualifier Y

QC Samples were not spiked with this compound A

RPD of sample and duplicate evaluated using +/-RL. Concentrations are <5X the RL h

Preparation or preservation holding time was exceeded The above sample is reported on a dry weight basis.

56

GENERAL ENGINEERING LABORATORIES, LLC 2040 Savage Road Charleston SC 29407 - (843) 556-8171 - www.gel.com Certificate of Analysis Company : Connecticut Yankee Atomic Power Address :

362 Injun Hollow Rd East Hampton, Connecticut 06424

Contact:

Mr. Jack McCarthy Project:

Soils PO# 002332 Report Date:

October 5, 2006 Client Sample ID:

Sample ID:

Matrix:

Collect Date:

Receive Date:

Collector:

Moisture:

Parameter Qualifier Result Us Rad Gamma Spec Analysis Gamma,Solid-FSS GAM & ALL FSS 226 Ingrowth Waived Actinium-228 0.946 Americium-241 U

0.0349 Bismuth-212 0.501 Bismuth-214 0.503 Cesium-134 U

0.0333 Cesium-137 0.0286 Cobalt-60 U

0.0223 Europium-152 U -0.00927 Europium-154 U -0.00156 Europium-155 U

0.0644 Lead-212 0.873 Lead-214 0.606 Manganese-54 U

0.0031 Niobium-94 U -0.00738 Potassiurn-40 12.7 Radium-226 0.503 Silver-108m U -0.0152 Thallium-208 0.271 9807-0000-01 OF 172275010 TS 14-SEP-06 21-SEP-06 Client 13.7%

Project:

YANK01204 Client ID:

YANKOO Vol. Recv.:

ncertainty LC TPU MDA Units DF Analyst Date Time Batch Mtd

+/-0.187

+/-0.117

+/-0.253 4-0.0831 4-0.0331

-/-0.0217 4/-0.0188 4-0.0519 4-0.0563

+/-0.0532 4/-0.0895 4-0.0895 4-0.0171 F/-0.0168

+/-1.11

+-0.0831

+/-0.0167

+/-0.0478 0.0607 0.0919 0.106 0.0286 0.020 0.0135 0.0177 0.0385 0.0482 0.047 0.0217 0.0282 0.0147 0.014 0.106 0.0286 0.0134 0.0142

+/-0.187

+/-0.117

+/-0.253

+/-0.0831

+/-0.0331

+/-0.0217

+/-0.0188

+/-0.0519

+/-0.0563

+/-0.0532

+/-0.0895

+/-0.0895

+/-0.0171

+/-0.0168

+/-1.11

+/-0.0831

+/-0.0167

+/-0.0478 0.128 0.188 0.225 0.060 0.0419 0.0285 0.0379 0.0799 0.103 0.0963 0.0448 0.0586 0.0311 0.0295 0.238 0.060 0.0279 0.0299 pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g MJHI1 10/03/06 1320 574335 1

The following Prep Methods were performed Method Description Analyst Date Time Prep Batch Dry Soil Prep Dry Soil Prep GL-RAD-A-021 JMB I 09/21/06 1745 571421 The following Analytical Methods were performed Method Description I

EML HASL 300, 4.5.2.3 Notes:

The Qualifiers in this report are defined as follows:

A quality control analyte recovery is outside of specified acceptance criteria Result is less than value reported 57

GENERAL ENGINEERING LABORATORIES, LLC 2040 Savage Road Charleston SC 29407 - (843) 556-8171 - www.gel.com Certificate of Analysis Company:

Connecticut Yankee Atomic Power Address :

362 Injun Hollow Rd East Hampton, Connecticut 06424 Report Date: October 5, 2006

Contact:

Mr. Jack McCarthy Project:

Soils PO# 002332 Client Sample ID:

9807-0000-01OF Project:

YANK01204 Sample ID:

172275010 Client ID:

YANKOOI Vol.,Recv.:

Parameter Qualifier Result Uncertainty LC TPU MDA Units DF Analyst Date Time Batch Mid Result is greater than value reported A

The TIC is a suspected aldol-condensation product B

Target analyte was detected in the associated blank BD Results are either below the MDC or tracer recovery is low C

Analyte has been confirmed by GC/MS analysis D

Results are reported from a diluted aliquot of the sample H

Analytical holding time was exceeded J

Value is estimated N/A Spike recovery limits do not apply. Sample concentration exceeds spike concentration by 4X or more R

Sample results are rejected U

Analyte was analyzed for, but not detected above the MDL, MDA, or LOD.

UI Gamma Spectroscopy-Uncertain identification X

Consult Case Narrative, Data Summary package, or Project Manager concerning this qualifier Y

QC Samples were not spiked with this compound A

RPD of sample and duplicate evaluated using +/-RL. Concentrations are <5X the RL h

Preparation or preservation holding time was exceeded The above sample is reported on a dry weight basis.

58

GENERAL ENGINEERING LABORATORIES, LLC 2040 Savage Road Charleston SC 29407 - (843)556-8171 - www.gel.com Certificate of Analysis Company; Connecticut Yankee Atomic Power Address :

362 Injun Hollow Rd East Hampton, Connecticut 06424

Contact:

Mr. Jack McCarthy Project:

Soils PO# 002332 Report Date:

October 5, 2006 Client Sample ID:

9807-0000-01 IF Project:

YANK01204 Sample ID:

172275011 Client ID:

YANK001 Matrix:

TS Vol. Recv.:

Collect Date:

14-SEP-06 Receive Date:

21-SEP-06 Collector:

Client Moisture:

16.5%

Parameter Qualifier Result Uncertainty LC TPU MDA Units DF Analyst Date Time Batch Mtd Rad Gamma Spec Analysis Gamna,.Solid-FSS GAM & ALL FSS 226 Ingrowth Waived Actinium-228 0.999

+/-0.202 0.0658

+/-0.202 0.142 pCi/g MJHI 10/03/06 1321 574335 1

Americium-241 U

-0.11

+/-0.0806 0.0678 +1-0.0806 0.139 pCi/g Bismuth-212 0.572

+/-0.334 0.149

+/-0.334 0.318 pCi/g Bismuth-214 0.604

+/-0.101 0.035

+/-0.101 0.0743 pCi/g Cesium-134 U

0.0109

+/-0.0337 0.0206 +/-0.0337 0.0441 pCi/g Cesium-137 U -0.0232

+/-0.0224 0.0172 +/-0.0224 0.0368 pCi/g Cobalt-60 U

0.0312

+/-0.0237 0.0212 +/-0.0237 0.0462 pCi/g Europium-152 U -0.0113

+/-0.0579 0.0501 +/-0.0579 0.105 pCi/g Europium-154 U

-0.0377

+/-0.0663 0.0526 +/-0.0663

.0.116 pCi/g Europium-155 U

0.0637

+/-0.064 0.0574

+/-0.064 0.118 pCi/g Lead-212 0.892

+/-0.0934 0.0297 +/-0.0934 0.0615 pCi/g Lead-214 0.637

+/-0.099 0.0347

+/-0.099 0.0728 pCi/g Manganese-54 U

0.0212

+/-0.0239 0.0213 +/-0.0239 0.0452 pCi/g Niobium-94 U

0.0181

+/-0.0195 0.0175 +/-0.0195 0.0373 pCi/g Potassium-40 13.5

+/-1.18 0.137

+/-1.18 0.313 pCi/g Radium-226 0.604

+/-0.101 0.035

+/-0.101 0.0743 pCi/g Silver-108m U -0.00596

+/-0.0191 0.0162 +/-0.0191 0.0342 pCi/g Thallium-208 0.274

+/-0.0528 0.0187 +/-0.0528 0.0397 pCi/g The following Prep Methods were performed Method Description Analyst Date Time Prep Batch Dry Soil Prep Dry Soil Prep GL-RAD-A-021 JMBI 09/21/06 1745 571421 The following Analytical Methods were performed Method Description EML HASL 300, 4.5.2.3 Notes:

The Qualifiers in this report are defmed as follows:

A quality control analyte recovery is outside of specified acceptance criteria Result is less than value reported 59

GENERAL ENGINEERING LABORATORIES, LLC 2040 Savage Road Charleston SC 29407 - (843) 556-8171 - www.gel.com Certificate of Analysis Company:

Connecticut Yankee Atomic Power Address:

362 Injun Hollow Rd East Hampton, Connecticut 06424 Report Date: October 5, 2006

Contact:

Mr. Jack McCarthy Project:

Soils PO# 002332 Client Sample ID:

9807-0000-01IF Project:

YANK01204 Sample ID:

172275011 Client ID:

YANK00I Vol. Recv.:

Parameter Qualifier Result Uncertainty LC TPU MDA Units DF Analyst Date Time Batch Mtd Result is greater than value reported A

The TIC is a suspected aldol-condensation product B

Target analyte was detected in the associated blank BD Results are either below the MDC or tracer recovery is low C

Analyte has been confirmed by GC/MS analysis D

Results are reported from a diluted aliquot of the sample H

Analytical holding time was exceeded J

Value is estimated N/A Spike recovery limits do not apply. Sample concentration exceeds spike concentration by 4X or more R

Sample results are rejected U

Analyte was analyzed for, but not detected above the MDL, MDA, or LOD.

Ul Gamma Spectroscopy--Uncertain identification X

Consult Case Narrative, Data Summary package, or Project Manager concerning this qualifier Y

QC Samples were not spiked with this compound A

RPD of sample and duplicate evaluated using +/-RL. Concentrations are <5X the RL h

Preparation or preservation holding time was exceeded The above sample is reported on a dry weight basis.

60

GENERAL ENGINEERING LABORATORIES, LLC 2040 Savage Road Charleston SC 29407 - (843) 556-8171 - www.gel.com Certificate of Analysis Company : Connecticut Yankee Atomic Power Address :

362 Injun Hollow Rd East Hampton, Connecticut 06424

Contact:

Mr. Jack McCarthy Project:

Soils PO# 002332 Report Date: October 5, 2006 Client Sample ID:

Sample ID:

Matrix:

Collect Date:

Receive Date:

Collector:

Moisture:

Parameter Qualifier Result Ui Rad Gamma Spec Analysis Gamma,Solid-FSS GAM & ALL FSS 226 Ingrowth Waived Actinium-228 0.909 Americium-241 U -0.0317 Bismuth-212 0.593 Bismuth-214 0.657 Cesium-134 UI 0.00 Cesium-137 U

0.0436 Cobalt-60 U -0.00429 Europiurn-152 U

0.0138 Europium-154 U -0.0425 Europiurn-155 U

0.0464 Lead-212 0.893 Lead-214 0.700 Manganese-54 U

0.041 Niobium-94 U

0.0269 Potassium-40 13.9 Radium-226 0.657 Silver-108m U -0.00418 Thallium-208 0.228 9807-0000-012F 172275012 TS 14-SEP-06 21-SEP-06 Client 1L fl Proiect:

YANK01204 Client ID:

YANK001 Vol. Recv.:

ncertainty LC TPU MDA Units DF Analyst Date Time Batch Mtd

+/-0.218

+/-0.155

+/-0.345

+/-0.0919

+/-0.0345

+/-0.0365

+/-0.0219

+/-0.066

+/-0.0811

+/-0.0703

+/-0.0692

+/-0.104

+/-0.0265

+/-0.021

+/-1.13

+/-0.0919

+/-0.026

+/-0.0521 0.0682 0.0882 0.161 0.0403 0.0287 0.0224 0.0174 0.0562 0.0627 0.0638 0.0314 0.0397 0.0215 0.0187 0.189 0.0403 0.0185 0.0214

+/-0.218

+/-0.155

+/-0.345

+/-0.0919

+/-0.0345

+/-0.0365

+/-0.0219

+/-0.066

+/-0.0811

+/-0.0703

+/-0.0692

+/-0.104

+/-0.0265

+/-0.021

+/-1.13

+/-0.0919

+/-0.026

+/-0.0521 0.148 0.182 0.343 0.0854 0.0606 0.0476 0.0392 0.118 0.137 0.132 0.0652 0.0832 0.046 0.0399 0.421 0.0854 0.0391 0.0453 pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g MJHI 10/03106 1321 574335 1

The following Prep Methods were performed Method Description Analyst Date Time Prep Batch Dry Soil Prep Dry Soil Prep GL-RAD-A-021 JMB1 09/21/06 1745 571421 The following Analytical Methods were performed Method Description I

EML HASL 300, 4.5.2.3 Notes:

The Qualifiers in this report are defined as follows:

A quality control analyte recovery is outside of specified acceptance criteria Result is less than value reported 61

GENERAL ENGINEERING LABORATORIES, LLC 2040 Savage Road Charleston SC 29407 - (843) 556-8171 - www.gel.com Certificate of Analysis Company:

Connecticut Yankee Atomic Power Address :

362 Injun Hollow Rd East Hampton, Connecticut 06424 Report Date:

October 5, 2006

Contact:

Mr. Jack McCarthy Project:

Soils PO# 002332 Client Sample ID:

9807-0000-012F Project:

YANK01204 Sample ID:

172275012 Client ID:

YANK001 Vol. Recv.:

Parameter Qualifier Result Uncertainty LC TPU MDA Units DF Analyst Date Time Batch Mtd Result is greater than value reported A

The TIC is a suspected aldol-condensation product B

Target analyte was detected in the associated blank BD Results are either below the MDC or tracer recovery is low C

Analyte has been confirmed by GC/MS analysis D

Results are reported from a diluted aliquot of the sample H

Analytical holding time was exceeded J

Value is estimated N/A Spike recovery limits do not apply. Sample concentration exceeds spike concentration by 4X or more R

Sample results are rejected U

Analyte was analyzed for, but not detected above the MDL, MDA, or LOD.

UI Gamma Spectroscopy--Uncertain identification X

Consult Case Narrative, Data Summary package, or Project Manager concerning this qualifier Y

QC Samples were not spiked with this compound A. RPD of sample and duplicate evaluated using +/-RL. Concentrations are <5X the RL h

Preparation or preservation holding time was exceeded The above sample is reported on a dry weight basis.

62

GENERAL ENGINEERING LABORATORIES, LLC 2040 Savage Road Charleston SC 29407 - (843) 556-8171 - www.gel.com Certificate of Analysis Company:

Connecticut Yankee Atomic Power Address :.

362 Injun Hollow Rd East Hampton, Connecticut 06424

Contact:

Mr. Jack McCarthy Project:

Soils PO# 002332 Report Date: October 5, 2006 Client Sample ID:

Sample ID:

Matrix:

Collect Date:

Receive Date:

Collector:

Moisture:

9807-0000-012FS 172275013 TS 14-SEP-06 21-SEP-06 Client 16.8%

Project:

Client ID:

Vol. Recv.:

YAN-KO1204 YANKOO I Parameter Qualifier Result Uncertainty LC -

TPU MDA Units DF Analyst Date Time Batch Mtd Rad Gamma Spec Analysis Gammna,Solid-FSS GAM & ALL FSS 226 Ingrowth Waived Actinium-228 0.848

+/-0.206 Americium-241 U -0.00901

+/-0.0398 Bismuth-212 0.794

+/-0.464 Bismuth-214 0.689

+/-0.120 Cesium-134 U

0.0733

+/-0.0547 Cesium-137 UI 0.00

+/-0.0737 Cobalt-60 U

-0.0099

+/-0.0316 Europium-152 U

0.0273

+/-0.0711 Europium-154 U

-0.0104

+1-0.099 Europium-155 UI 0.00

+/-0.0984 Lead-212 0.737

+/-0.0899 Lead-214 0.714

+/-0.104 Manganese-54 U

0.0221

+/-0.0316 Niobium-94 U

0.0163

+/-0.0292 Potassium--40 13.7

+/-1.14 Radium-226 0.689

+/-0.120 Silver-108m U

-0.0206

+/-0.0243 Thallium-208 0.333

+/-0.0617 0.0808 0.0344 0.183 0.045 0.0352 0.0254 0.0255 0.0612 0.0705 0.0517 0.0456 0.0443 0.0276 0.0256 0.234 0.045 0.0205 0.0233

+/-0.206

+/-0.0398

+/-0.464

+/-0.120

+/-0.0547

+/-0.0737

+/-0.0316

+/-0.0711

+/-0.099

+/-0.0984

+1-0.0899

+/-0.104

+/-0.0316

+/-0.0292

+/-1.14

+/-0.120

+/-0.0243

+/-0.0617 0.174 0.0707 0.390 0.0951 0.0739 0.0537 0.0555 0.128 0.153 0.107 0.0937 0.0926 0.0585 0.0538 0.513 0.0951 0.0431 0.0493 pCi/g pCilg pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g MJHI 10/03/06 1321 574335 1

The following Prep Methods were performed Method Description Analyst Date Time Prep Batch Dry Soil Prep Dry Soil Prep GL-RAD-A-021 JMB1 09/21/06 1745 571421 The following Analytical Methods were performed Method Description 1

EML HASL 300, 4.5.2.3 Notes:

The Qualifiers in this report are defined as follows:

A quality control analyte recovery is outside of specified acceptance criteria Result is less than value reported 63

GENERAL ENGINEERING LABORATORIES, LLC 2040 Savage Road Charleston SC 29407 - (843) 556-8171 - www.gel.com Certificate of Analysis Company:

Connecticut Yankee Atomic Power Address 362 Injun Hollow Rd East Hampton, Connecticut 06424 Report Date: October 5, 2006

Contact:

Mr. Jack McCarthy Project:

Soils PO# 002332 Client Sample ID:

9807-0000-012FS Project:

YANK01204 Sample ID:

172275013 Client ID:

YANKOOI Vol. Recv.:

Parameter Qualifier Result Uncertainty LC TPU MDA Units DF Analyst Date Time Batch Mtd Result is greater than value reported A

The TIC is a suspected aldol-condensation product B

Target analyte was detected in the associated blank BD. Results are either below the MDC or tracer recovery is low C

Analyte has been confirmed by GC/MS analysis D

Results are reported from a diluted aliquot of the sample H

Analytical holding time was exceeded J

Value is estimated N/A Spike recovery limits do not apply. Sample concentration exceeds spike concentration by 4X or more R

Sample results are rejected U

Analyte was analyzed for, but not detected above the MDL, MDA, or LOD.

UI Gamma Spectroscopy-Uncertain identification X

Consult Case Narrative, Data Summary package, or Project Manager concerning this qualifier Y

QC Samples were not spiked with this compound A

RPD of sample and duplicate evaluated using +/-RL. Concentrations are <5X the RL h

Preparation or preservation holding time was exceeded The above sample is reported on a dry weight basis.

64

GENERAL ENGINEERING LABORATORIES, LLC 2040 Savage Road Charleston SC 29407 - (843) 556-8171 - www.gel.com Certificate of Analysis Company:

Connecticut Yankee Atomic Power Address:

362 Injun Hollow Rd East Hampton, Connecticut 06424 Contact Mr. Jack McCarthy Project:

Soils PO# 002332 Report Date: October 5, 2006 Client Sample ID:

Sample ID:

Matrix:

Collect Date:

Receive Date:

Collector:

Moisture:

9807-0000-013F 172275014 TS 14-SEP-06 21-SEP-06 Client 14.6%

Project:

YANK01204 Client ID:

YANK001 Vol. Recv.:

Parameter Qualifier Result Uncertainty LC TPU MDA Units DF Analyst Date Time Batch Mtd Rad Alpha Spec Analysis Alphaspec Am241, Cm, Solid ALL FSS Americium-241 U

0.0935 Curium-242 U

0.00 Curium-243/244 U

-0.026 Alphaspec Pu, Solid-ALL FSS Plutonium-238 U

0.0164 Plutonium-239/240 U

-0.0719 Liquid Scint Pu241, Solid-ALL FSS Plutonium-241 U

4.77 Rad Gamma Spec Analysis Gamma,Solid-FSS GAM & ALL FSS 226 Ingrowth Waived Actinium-228 1.02 Americium-241 U

-0.0146 Bismuth-212 0.755 Bismuth-214 0.547 Cesium-134 U

0.0516 Cesium-137 U -0.00251 Cobalt-60 U

0.0212 Europium-152 U

-0.017 Europiumn-154 U

-0.0293 Europium-155 U

0.0349 Lead-212 0.791 Lead-214 0.703 Manganese-54 U

0.0418 Niobium-94 U

0.00697 Potassium-40 15.2 Radium-226 0.547 Silver-108m U-0.000887 Thallium-208 0.322 Rad Gas Flow Proportional Counting GFPC, Sr90, solid-ALL FSS Strontium-90 U

0.0134 Rad Liquid Scintillation Analysis

+/-0.132 4-0.0752

-/-0.0294 0.0561 0.00 0.0561

+/-0.133

+/-0.0752

+/-0.0296 0.210 0.104 0.210 0.242 0.276 pCi/g pCi/g pCi/g pCi/g pCi/g

+/-0.110 0.0863

+/-0.110

-/-0.0894 0.103 +/-0.0897

+/-8.34 6.78

+/-8.35 14.2 pCi/g

+/-0.172

-/-0.0306

+/-0.351

+/-0.111 r/-0.0574 4-0.0261 4-0.0288 4-0.0579

+/-0.0998 4/-0.0463 P/-0.0798

+/-0.097 F/-0.0282 F/-0.0239

+/-1.17

+/-0.111

+/-0.0188

+/-0.0575 0.0702 0.0251 0.153 0.0394 0.0281 0.0217 0.0259 0.0467 0.0684 0.0427 0.0376 0.0344 0.021 0.0204 0.176 0.0394 0.0163 0.019

+/-0.172

+/-0.0306

+/-0.351

+/-0.111

+/-0.0574

+/-0.0261

+/-0.0288

+/-0.0579

+/-0.0998

+/-0.0463

+/-0.0798

+/-0.097

+/-0.0282

+/-0.0239

+/-1.17

+/-0.111

+/-0.0188

+/-0.0575 0.153 0.0518 0.329 0.0838 0.0597 0.0463 0.0566 0.0986 0.150 0.0886 0.0775 0.0726 0.0451 0.0433 0.400 0.0838 0.0347 0.0406 0.0368 13.6 pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g TCI 09/28/06 1156 572120 1

TCI 09/28/06 1156 572121 2

TC1 09/29/06 2302 572122 3

MJHI 10/03/06 1322 574335 4

KSDI 09/28/06 0734 572301 5

DFAI 09/27/06 1858 571884 6

LSC, Tritium Dist, Solid-HTD2,ALL FSS Tritium U

3.43

+/-0.02'11 0.0159 +/-0.0211

+/-7.85 6.38

+/-7.85 65

GENERAL ENGINEERING LABORATORIES, LLC 2040 Savage Road Charleston SC 29407 - (843) 556-8171 - www.gel.com Certificate of Analysis Company : Connecticut Yankee Atomic Power Address:

362 Injun Hollow Rd East Hampton, Connecticut 06424

Contact:

Mr. Jack McCarthy Project:

Soils PO# 002332 Report Date:

October 5, 2006 Client Sample ID:

Sample ID:

9807-00O0-013F 172275014 Project:

YANKO1204 Client ID:

YANK001 Vol. Recv.:

Parameter Qualifier Result Rad Liquid Scintillation Analysis Liquid Scint C14, Solid AlI, FSS Carbon-14 U

-0.115 Liquid Scint Fe55, Solid-ALL FSS Iron-55 U

-26.8 Liquid Scin Ni63, Solid-ALL FSS Nickel-63 U

-3.05 Liquid Scint Tc99, Solid-ALL FSS Technetium-99 U

0.153 Uncertainty LC TPU MDA Units DF Analyst Date Time Batch Mtd

+/-0.101 0.0866

+/-0.101

+/-36.1 26.4

+/-36.1

+/-9.26 7.85

+/-9.26 0.176 55.2 16.2 0.324 pCi/g pCi/g pCi/g pCi/g AXD2 09/25/06 2135 571880 7 MXPI 09/28/06 1809 571874 8

MXPI 09/29/06 2015 571876 9

KXRI 10/02/06 1159 571877 10

+/-0.193 0.159

+/-0.193 The following Prep Methods were performed Method Description Analyst Date Time Prep Batch Dry Soil Prep Dry Soil Prep GL-RAD-A-021 JMBI 09/21/06 1745 571421 The following Analytical Methods were performed Method Description I

DOE EML HASL-300, Am-05-RC Modified 2

DOE EML HASL-300, Pu-II-RC Modified 3

DOE EML HASL-300, Pu-1 I-RC Modified 4

EML HASL 300, 4.5.2.3 5

EPA 905.0 Modified 6

EPA 906.0 Modified 7

EPA EERF C-0I Modified 8

DOE RESL Fe-I, Modified 9

DOE RESL Ni-1, Modified 10 DOE EML HASL-300, Tc-02-RC Modified Surrogate/Tracer recovery Test Recovery%

Acceptable Limits Americium-243 Plutonium-242 Carrier/Tracer Recovery Carrier/Tracer Recovery Carrier/Tracer Recovery Carrier/Tracer Recovery Carrier/Tracer Recovery Alphaspec Am241, Cm, Solid ALL Alphaspec Pu, Solid-ALL FSS Liquid Scint Pu241, Solid-ALL Fý GFPC, Sr90, solid-ALL FSS Liquid Scint Fe55, Solid-ALL FS Liquid Scint Ni63, Solid-ALL FS Liquid Scint Tc99, Solid-ALL FS 63 93 100 89 66 53 72 (15%-125%)

(15%-125%)

(25%-125%)

(25%-125%)

(15%-125%)

(25%-125%)

(15%-125%)

66

GENERAL ENGINEERING LABORATORIES, LLC 2040 Savage Road Charleston SC 29407 - (843) 556-8171 - www.gel.com Certificate of Analysis Company:

Connecticut Yankee Atomic Power Address:

362 Injun Hollow Rd East Hampton, Connecticut 06424 Report Date: October 5, 2006

Contact:

Mr. Jack McCarthy Project:

Soils PO# 002332 Client Sample ID:

9807-0000-013F Project:

YANK01204 Sample ID:

172275014 Client ID:

YANKOO Vol. Recv.:

Parameter Qualifier Result Uncertainty LC TPU MDA Units DF Analyst Date Time Batch Mtd Notes:

The Qualifiers in this report are defined as follows:

A quality control analyte recovery is outside of specified acceptance criteria Result is less than value reported Result is greater than value reported A

The TIC is a suspected aldol-condensation product B

Target analyte was detected in the associated blank BD Results are either below the MDC or tracer recovery is low C

Analyte has been confirmed by GC/MS analysis D

Results are reported from a diluted aliquot of the sample H

Analytical holding time was exceeded J

Value is estimated N/A Spike recovery limits do not apply. Sample concentration exceeds spike concentration by 4X or more R

Sample results are rejected U

Analyte was analyzed for, but not detected above the MDL, MDA, or LOD.

UI Gamma Spectroscopy--Uncertain identification X

Consult Case Narrative, Data Summary package, or Project Manager concerning this qualifier Y

QC Samples were not spiked with this compound A

RPD of sample and duplicate evaluated using +/-RL. Concentrations are <5X the RL h

Preparation or preservation holding time was exceeded The above sample is reported on a dry weight basis.

67

GENERAL ENGINEERING LABORATORIES, LLC 2040 Savage Road Charleston SC 29407 - (843) 556-8171 - www.gel.com Certificate of Analysis Company:

Connecticut Yankee Atomic Power Address:

362 Injun Hollow Rd East Hampton, Connecticut 06424

Contact:

Mr. Jack McCarthy Project:

Soils PO# 002332 Report Date: October 5, 2006 Client Sample ID:

Sample ID:

Matrix:

Collect Date:

Receive Date:

Collector:

Moisture:

Parameter Qualifier Result Ui Rad Gamma Spec Analysis Gamma,Solid-FSS GAM & ALL FSS 226 Ingrowth Waived Actinium-228 0.938 Americium-241 U -0.00605 Bismuth-212 0.845 Bismuth-214 0.584 Cesium-134 UI 0.00 Cesium-137 U 0.00818 Cobalt-60 U

0.011 Europium-152 U -0.0249 Europium-154 U

0.0465 Europium-155 U

0.0523 Lead-212 0.950 Lead-214 0.708 Manganese-54 U

0.00474.

Niobium-94 U

0.0238 Potassiunm-40 15.8 Radium-226 0.584 Silver-108m U -0.00146 Thallium-208 0.307 9807-0000-014F 172275015 TS 18-SEP-06 21-SEP-06 Client Project:

YANK01204 Client ID:

YANK001 Vol. Recv.:

15%

icertainty LC TPU MDA Units DF Analyst Date Time Batch Mtd

+/-0.203

+/-0.0653

+/-0.285

+/-0.124 F/-0.0329 Y-0.0237 F/-0.0186

+/-0.0482 F/-0.0658

+/-0.0687

+/-0.0975

+/-0.109

+/-0.0277

+/-0.0237

+/-1.38

+/-0.124

+I-0.0178

+/-0.0526 0.0562 0.0549 0.119 0.0344 0.0263 0.0208 0.0163 0.0388 0.0603 0.0453 0.0271 0.0295 0.0178 0.0166 0.128 0.0344 0.0146 0.0172

+/-0.203

+/-0.0653

+/-0.285

+/-0.124

+/-0.0329

+/-0.0237

+/-0.0186

+/-0.0482

+/-0.0658

+/-0.0687

+/-0.0975

+/-0.109

+/-0.0277

+/-0.0237

+/-1.38

+/-0.124

+1-0.0178

+/-0.0526 0.123 0.114 0.259 0.0732 0.0557 0.0441 0.0366 0.0825 0.131 0.0942 0.0565 0.0626 0.0383 0.0354 0.296 0.0732 0.0311 0.0368 pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCilg pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g MJH1 10/03/06 1322 574335 1

The following Prep Methods were performed Method Description Analyst Date Time Prep Batch Dry Soil Prep Dry Soil Prep GL-RAD-A-021 JMB1 09/21/06 1745 571421 The following Analytical Methods were performed Method Description I

EML HASL 300, 4.5.2.3 Notes:

The Qualifiers in this report are defined as follows:

A quality control analyte recovery is outside of specified acceptance criteria Result is less than value reported 68

GENERAL ENGINEERING LABORATORIES, LLC 2040 Savage Road Charleston SC 29407 - (843) 556-8171 - www.gel.com Certificate of Analysis Company:

Connecticut Yankee Atomic Power Address:

362 Injun Hollow Rd East Hampton, Connecticut 06424 Report Date: October 5, 2006

Contact:

Mr. Jack McCarthy Project:

Soils PO# 002332 Client Sample ID:

9807-0000-014F Project:

YANK01204 Sample ID:

172275015 Client ID:

yANK001I Vol. Recv.:

Parameter Qualifier Result Uncertainty LC TPU MDA Units DF Analyst Date Time Batch Mtd Result is greater than value reported A

The TIC is a suspected aldol-condensation product B

Target analyte was detected in the associated blank BD Results are either below the MDC or tracer recovery is low C

Analyte has been confirmed by GC/MS analysis D

Results are reported from a diluted aliquot of the sample H

Analytical holding time was exceeded J

Value is estimated.

N/A Spike recovery limits do not apply. Sample concentration exceeds spike concentration by 4X or more R

Sample results are rejected U

Analyte was analyzed for, but not detected above the MDL, MDA, or LOD.

UI Gamma Spectroscopy-Uncertain identification X

Consult Case Narrative, Data Summary package, or Project Manager concerning this qualifier Y

QC Samples were not spiked with this compound A

RPD of sample and duplicate evaluated using +/-RL. Concentrations are <5X the RL h

Preparation or preservation holding time was exceeded The above sample is reported on a dry weight basis.

69

GENERAL ENGINEERING LABORATORIES, LLC 2040 Savage Road Charleston SC 29407 - (843) 556-8171 - www.gel.com Certificate of Analysis Company :

Connecticut Yankee Atomic Power Address :

362 Injun Hollow Rd East Hampton, Connecticut 06424

Contact:

Mr. Jack McCarthy Project:

Soils PO# 002332 Report Date: October 5, 2006 Client Sample ID:

Sample ID:

Matrix:

Collect Date:

Receive Date:

Collector:

Moisture:

9807-0000-015F 172275016 TS 18-SEP-06 21-SEP-06 Client 11.3%

Project:

YANK01204 Client ID:

YANK001 Vol. Recv.:

Parameter Qualifier Result Uncertainty LC TPU MDA Units DF Analyst Date Time Batch Mtd Rad Gamma Spec Analysis Ganima,Solid-FSS GAM & ALL FSS 226 Ingrowth Waived Actinium-228 0.702

+/-0.169 Americium-241 U

0.0258

+/-0.0299 Bismuth-212 0.486

+/-0.316 Bismuth-214 0.491

+/-0.103 Cesium-134 U

0.0563

+/-0.048 Cesium-137 U

0.0129

+/-0.0242 Cobalt-60 U

0.00658

+/-0.0246 Europium-152 U

-0.0298

+/-0.0474 Europium-154 U

-0.0013

+/-0.0656 Europium-155 U

0.0486

+/-0.0744 Lead-212 0.686

+/-0.0571 Lead-214 0.552

+/-0.082 Manganese-54 U -0.00757

+/-0.028 Niobium-94 U-0.000502

+/-0.0218 Potassium-40 11.8

+/-1.02 Radium-226 0.491

+/-0.103 Silver-108m U -0.00694

+/-0.0193 Thallium-208 0.215

+/-0.0455 0.0373 0.0297 0.148 0.0345 0.027 0.0219 0.0216 0.0416 0.056 0.0449 0.0278 0.0324 0.0199 0.0187 0.181 0.0345 0.0169 0.0192

+/-0.169

+/-0.0299

+/-0.316

+/-0.103

+/-0.048

+/-0.0242

+/-0.0246

+/-0.0474

+/-0.0656

+1-0.0744

+/-0.0571

+/-0.082

+/-0.028

+/-0.0218

+/-1.02

+/-0.103

+/-0.0193

+/-0.0455 0.0864 0.0611 0.318 0.0739 0.0573 0.0466 0.0477 0.0883 0.124 0.0929 0.0578 0.0684 0.0429 0.040 0.408 0.0739 0.0358 0.0411 pCi/g pCi/g pCi/g pCilg

.pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g MJHl 10/03/06 1323 574335 1

The following Prep Methods were performed Method Description Analyst Date Time Prep Batch Dry Soil Prep Dry Soil Prep GL-RAD-A-021 JMBI 09/21/06 1745 571421 The following Analytical Methods were performed Method Description I

EML HASL 300,4.5.2.3 Notes:

The Qualifiers in this report are defined as follows:

A quality control analyte recovery is outside of specified acceptance criteria Result is less than value reported 70

GENERAL ENGINEERING LABORATORIES, LLC 2040 Savage Road Charleston SC 29407 - (843) 556-8171 - www.gel.com Certificate of Analysis Company:

Connecticut Yankee Atomic Power Address:

362 Injun Hollow Rd East Hampton, Connecticut 06424 Report Date: October 5, 2006

Contact:

Mr. Jack McCarthy Project:

Soils PO# 002332 Client Sample ID:

9807-0000-015F Project:

YANK01204 Sample ID:

172275016 ClientID:

YANK001 Vol. Recv.:

Parameter Qualifier Result Uncertainty LC TPU MDA Units DF Analyst Date Time Batch Mtd Result is greater than value reported A

The TIC is a suspected aldol-condensation product B

Target analyte was detected in the associated blank BD Results are either below the MDC or tracer recovery is low C

Analyte has been confirmed by GC/MS analysis D

Results are reported from a diluted aliquot of the sample H

Analytical holding time was exceeded J

Value is estimated N/A Spike recovery limits do not apply. Sample concentration exceeds spike concentration by 4X or more R

Sample results are rejected U

Analyte was analyzed for, but not detected above the MDL, MDA, or LOD.

UI Gamma Spectroscopy--Uncertain identification X

Consult Case Narrative, Data Summary package, or Project Manager concerning this qualifier Y

QC Samples were not spiked with this compound A

RPD of sample and duplicate evaluated using +/-RL. Concentrations are <5X the RL h

Preparation or preservation holding time was exceeded The above sample is reported on a dry weight basis.

71

GENERAL ENGINEERING LABORATORIES, LLC 2040 Savage Road Charleston SC 29407 - (843) 556-8171 - www.gel.com Certificate of Analysis Company : Connecticut Yankee Atomic P.ower Address :

362 Injun Hollow Rd East Hampton, Connecticut 06424

Contact:

Mr. Jack McCarthy Project:

Soils PO# 002332 Report Date:

October 5, 2006 Client Sample ID:

Sample ID:

Matrix:

Collect Date:

Receive Date:

Collector:

Moisture:

9807-0000-016F 172275017 TS 18-SEP-06 21-SEP-06 Client 15.5%

Project:

Client ID:

Vol. Recv.:

YANK01204 YANKOOI Parameter Qualifier Result Uncertainty LC TPU MDA Units DF Analyst Date Time Batch Mtd Rad Gamma Spec Analysis GammaSolid-FSS GAM & ALL FSS 226 Ingrowth Waived Actinium-228 0.803

+/-0.139 Americium-241 U

-0.0807

+/-0.109 Bismuth-212 0.705

+/-0.192 Bismuth-214 0.588

+/-0.0736 Cesium-134 UI 0.00

+/-0.0229 Cesium-137 U

0.00601

+/-0.0211 Cobalt-60 U -0.00939

+/-0.0171 Europium-152 U

-0.0448

+/-0.0436 Europium-154 U

0.0344

+/-0.0517 Europiurn-155 U

-0.03

+/-0.0552 Lead-212 0.776

+/-0.0539 Lead-214 0.679

+/-0.0763 Manganese-54 0.0304

+/-0.0219 Niobium-94 U

0.00961

+/-0.0156 Potassium-40 14.1

+/-0.801 Radium-226 0.588

+/-0.0736 Silver-108m U

0.00385

+/-0.0144 Thallium-208 0.264

+/-0.0388 0.0499 0.0814 0.099 0.0279 0.0134 0.0157 0.0139 0.0367 0.047 0.0492 0.0231 0.0287 0.0132 0.0142 0.117 0.0279 0.0127 0.0122

+/-0.139

+/-0.109

+/-0.192

+/-0.0736

+/-0.0229

+/-0.0211

+/-0.0171

+/-0.0436

+/-0.0517

+/-0.0552

+/-0.0539

+/-0.0763

+/-0.0219

+/-0.0156

+/-0.801

+/-0.0736

+/-0.0144

+/-0.0388 0.106 0.169 0.211 0.0585 0.0287 0.0331 0.0302 0.0767 0.101 0.102 0.0479 0.0599 0.0281 0.0298 0.258 0.0585 0.0267 0.026 pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g MiHi 10/03/06 1323 574335 1

The following Prep Methods were performed Method Description Analyst Date Time Prep Batch Dry Soil Prep Dry Soil Prep GL-RAD-A-021 JMBI 09/21/06 1745 571421 The following Analytical Methods were performed Method Description I

EML HASL 300, 4.5.2.3 Notes:

The Qualifiers in this report are defined as follows:

A quality control analyte recovery is outside of specified acceptance criteria Result is less than value reported 72

GENERAL ENGINEERING LABORATORIES, LLC 2040 Savage Road Charleston SC 29407 - (843) 556-8171 - www.gel.com Certificate of Analysis Company:

Connecticut Yankee Atomic Power Address:

362 Injun Hollow Rd East Hampton, Connecticut 06424 Report Date:

October 5, 2006

Contact:

Mr. Jack McCarthy Project:

Soils PO# 002332 Client Sample ID:

9807-0000-016F Proiect:

YANK01204 Sample ID:

172275017 Client ID:

YANKOOI Vol. Recv.:

Parameter Qualifier Result Uncertainty LC TPU MDA Units DF Analyst Date Time Batch Mtd Result is greater than value reported A

The TIC is a suspected aldol-condensation product B

Target analyte was detected in the associated blank BD Results are either below the MDC or tracer recovery is low C

Analyte has been confirmed by GC/MS analysis D

Results are reported from a diluted aliquot of the sample H

Analytical holding time was exceeded J

Value is estimated N/A Spike recovery limits do not apply. Sample concentration exceeds spike concentration by 4X or more R

Sample results are rejected U

Analyte was analyzed for, but not detected above the MDL, MDA, or LOD.

UI Gamma Spectroscopy--Uncertain identification X

Consult Case Narrative, Data Summary package, or Project Manager concerning this qualifier Y

QC Samples were not spiked with this compound A

RPD of sample and duplicate evaluated using +/-RL. Concentrations are <5X the RL h

Preparation or preservation holding time was exceeded The above sample is reported on a dry weight basis.

73

GENERAL ENGINEERING LABORATORIES, LLC 2040 Savage Road Charleston SC 29407 - (843) 556-8171 - www.gel.com Certificate of Analysis Company:

Connecticut Yankee Atomic Power Address :

362 Injun Hollow Rd East Hampton, Connecticut 06424

Contact:

Mr. Jack McCarthy Project:

Soils PO# 002332 Report Date: October 5, 2006 Client Sample ID:

Sample ID:

Matrix:

Collect Date:

Receive Date:

Collector:

Moisture:

9807-0000-017F 172275018 TS 18-SEP-06 2 1-SEP-06 Client 14.2%

Proiect:

YANK01204 Client ID:

YANK001 Vol. Recv.:

Parameter Qualifier Result Uncertainty LC TPU MDA Units DF Analyst Date Time Batch Mtd Rad Gamma Spec Analysis Gammna,Solid-FSS GAM & ALL FSS 226 Ingrowth Waived Actinium-228 0.687

+/-0.127 Americium-241 U

0.0675

+1-0.0841 Bismuth-212 0.582

+/-0.214 Bismuth-214 0.537

+/-0.0692 Cesium-134 U1 0.00

+/-0.0214 Cesium-137 0.0334

+/-0.0292 Cobalt-60 U

0.00613

+/-0.0115 Europium-152 U

-0.011

+/-0.0452 Europium-154 U

0.0334

+/-0.0437 Europium-155 U

0.0628

+/-0.0471 Lead-212 0.727

+/-0.0505 Lead-214 0.545

+/-0.0642 Manganese-54 U

0.0189

+/-0.0168 Niobium-94 U

0.00811

+/-0.0127 Potassium-40 12.8

+/-0.696 Radium-226 0.537

+/-0.0692 Silver-108m U -0.00478

+/-0.0128 Thallium-208 0.244

+/-0.0341 0.0429 0.0478 0.0884 0.0241 0.0165 0.0119 0.0126 0.0348 0.0391 0.0445 0.0214 0.0253 0.012 0.0117 0.0872 0.0241 0.0109 0.0115

+/-0.127

+/-0.0841

+/-0.214

+/-0.0692

+/-0.0214

+/-0.0292

+/-0.0115

+/-0.0452

+/-0.0437

+/-0.0471

+/-0.0505

+/-0.0642

+/-0.0168

+/-0.0127

+/-0.696

+/-0.0692

+/-0.0128

+/-0.0341 0.0915 0.0987 0.188 0.0506 0.0347 0.0253 0.0272 0.0725 0.0839 0.0916 0.0441 0.0527 0.0256 0.0247 0.195 0.0506 0.0229 0.0244 pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g MJH1 10/03/06 1323 574335 1

The following Prep Methods were performed Method Description Analyst Date Time Prep Batch Dry Soil Prep Dry Soil Prep GL-RAD-A-021 JMB1 09/21106 1745 571421 The following Analytical Methods were performed Method Description I

EML HASL 300, 4.5.2.3 Notes:

The Qualifiers in this report are defined as follows:

A quality control analyte recovery is outside of specified acceptance criteria Result is less than value reported 74

GENERAL ENGINEERING LABORATORIES, LLC 2040 Savage Road Charleston SC 29407 - (843) 556-8171 - www.gel.com Certificate of Analysis Company:

Connecticut Yankee Atomic Power Address :

362 Injun Hollow Rd East Hampton, Connecticut 06424 Report Date: October 5, 2006

Contact:

Mr. Jack McCarthy Project:

Soils PO# 002332 Client Sample ID:

9807-0000-017F Project:

YANK01204 Sample ID:

172275018 Client lID:

YANK001 Vol. Recv.:

Parameter Qualifier Result Uncertainty LC TPU MDA Units DF Analyst Date Time Batch Mtd Result is greater than value reported A

The TIC is a suspected aldol-condensation product B

Target analyte was detected in the associated blank BD Results are either below the MDC or tracer recovery is low C

Analyte has been confirmed by GC/MS analysis D

Results are reported from a diluted aliquot of the sample H

Analytical holding time was exceeded J

Value is estimated N/A Spike recovery limits do not apply. Sample concentration exceeds spike concentration by 4X or more R

Sample results are rejected U

Analyte was analyzed for, but not detected above the MDL, MDA, or LOD.

UT Gamma Spectroscopy-Uncertain identification X

Consult Case Narrative, Data Summary package, or Project Manager concerning this qualifier Y

QC Samples were not spiked with this compound A

RPD of sample and duplicate evaluated using +/-RL. Concentrations are <5X the RL h

Preparation or preservation holding time was exceeded The above sample is reported on a dry weight basis.

75

GENERAL ENGINEERING LABORATORIES, LLC 2040 Savage Road Charleston SC 29407 - (843) 556-8171 - www.gel.com Certificate of Analysis Company:

Connecticut Yankee Atomic Power Address :

362 Injun Hollow Rd East Hampton, Connecticut 06424

Contact:

Mr. Jack McCarthy Project:

Soils PO# 002332 Report Date: October 5, 2006 Client Sample ID:

Sample ID:

Matrix:

Collect Date:

Receive Date:

Collector.

Moisture; 9807-0000-018F 172275019 TS 18-SEP-06 21-SEP-06 Client 14.8%

Proiect:

YANK01204 Client ID:

YANKOO Vol. Recv.:

Parameter Qualifier Result Uncertainty LC TPU MDA Units DF Analyst Date Time Batch Mtd Rad Gamma Spec Analysis Gamma,Solid-FSS GAM & ALL FSS 226 Ingrowrh Waived Actinium-228 0.923

+/-0.174 Americium-241 U

0.0219

+/-0.0658 Bismuth-212 0.440

+/-0.270 Bismuth-214 0.464

+/-0.0854 Cesium-134 U

0.0248

+/-0.0274 Cesium-137 U

0.00239

+/-0.0186 Cobalt-60 U -0.00503

+/-0.0201 Europium-152 U

-0.0649

+/-0.0619 Europium-154 U

0.0374

+/-0.0633 Europium-155 U

0.0114

+/-0.0528 Lead-212 0.691

+/-0.0767 Lead-214 0.624

+/-0.0813 Manganese-54 U

0.0193

+/-0.0205 Niobium-94 U

0.00598

+/-0.0168 Potassium-40 13.2

+/-1.11 Radium-226 0.464

+/-0.0854 Silver-108m U

0.00189

+/-0.0166 Thallium-208 0.251

+/-0.0431 0.068 0.0546 0.126 0.0291 0.0208 0.016 0.0164 0.0411 0.0564 0.0483 0.0251 0.0297 0.0153 0.0153 0.152 0.0291 0.0147 0.0153

+/-0.174

+/-0.0658

+/-0.270

+/-0.0854

+/-0.0274

+/-0.0186

+/-0.0201

+/-0.0619

+/-0.0633

+/-0.0528

+i-0.0767

+/-0.0813

+/-0.0205

+/-0.0168

+/-1.11

+/-0.0854

+/-0.0166

+/-0.0431 0.136 0.109 0.252 0.0582 0.0415 0.032 0.0329 0.0821 0.113 0.0965 0.0501 0.0594 0.0305 0.0305 0.304 0.0582 0.0294 0.0305 pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g MJH1 10/03/06 1338 574335 1

The following Prep Methods were performed Method Description Analyst Date Time Prep Batch Dry Soil Prep Dry Soil Prep GL-RAD-A-021 JMiBI 09/21/06 1745 571421 The following Analytical Methods were performed Method Description 1

EMNL HASL 300, 4.5.2.3 Notes:

The Qualifiers in this report are defined as follows:

A quality control analyte recovery is outside of specified acceptance criteria Result is less than value reported 76

GENERAL ENGINEERING LABORATORIES, LLC 2040 Savage Road Charleston SC 29407 - (843) 556-8171 - www.gel.com Certificate of Analysis Company Connecticut Yankee Atomic Power Address :

362 Injun Hollow Rd East Hampton, Connecticut 06424 Report Date: October 5, 2006

Contact:

Mr. Jack McCarthy Project:

Soils PO# 002332 Client Sample ID:

9807-0000-018F Project:

YANK01204 Sample ID:

172275019 Client ID:

YANK001 Vol. Recv.:

Parameter Qualifier Result Uncertainty LC TPU MDA Units DF Analyst Date Time Batch Mtd Result is greater than value reported A

The TIC is a suspected aldol-condensation product B

Target analyte was detected in the associated blank BD Results are either below the MDC or tracer recovery is low C

Analyte has been confirmed by GC/MS analysis D

Results are reported from a diluted aliquot of the sample H

Analytical holding time was exceeded J

Value is estimated N/A Spike recovery limits do not apply. Sample concentration exceeds spike concentration by 4X or more R

Sample results are rejected U

Analyte was analyzed for, but not detected above the MDL, MDA, or LOD.

UI Gamma Spectroscopy-Uncertain identification X

Consult Case Narrative, Data Summary package, or Project Manager concerning this qualifier Y

QC Samples were not spiked with this compound A

RPD of sample and duplicate evaluated using +/-RL. Concentrations are <5X the RL h

Preparation or preservation holding time was exceeded The above sample is reported on a dry weight basis.

77

GENERAL ENGINEERING LABORATORIES, LLC 2040 Savage Road Charleston SC 29407 - (843) 556-8171 - www.gel.com Certificate of Analysis Company:

Connecticut Yankee Atomic Power Address:

362 Injun Hollow Rd.......

East Hampton, Connecticut 06424

Contact:

Mr. Jack McCarthy Project:

Soils PO# 002332 Report Date:

October 5, 2006 Client Sample ID:

Sample ID:

Matrix:

Collect Date:

Receive Date:

Collector:

lMni~tiir" 9807-0000-018FS 172275020 TS 18-SEP-06 21-SEP-06 Client 1A 10/-

Proiect:

Client ED:

Vol. Recv.:

YANK01204.

YANK001 Parameter Qualifier Result Uncertainty LC TPU MDA Units DF Analyst Date Time Batch Mtd Rad Gamma Spec Analysis Gamrna,Solid-FSS GAM & ALL FSS 226 Ingrowth Waived Actinium-228 0.691

+/-0.160 Americium-241 U 0.000277

+/-0.0873 Bismuth-212 0.470

+/-0.304 Bismuth-214 0.547

+/-0.110 Cesium-134 U

0.0256

+/-0.0423 Cesium-137 U

0.00688

+/-0.021 Cobalt-60 U

0.0011

+/-0.0226 Europium-152 U

0.00634

+/-0.0716 Europium-154 U

-0.0402

+/-0.0712 Europium-155 U

-0.0112

+/-0.0615 Lead-212 0.799

+/-0.0923 Lead-214 0.544

+/-0.102 Manganese-54 U

0.0253

+/-0.024 Niobium-94 U -0.00717

+/-0.0195 Potassium-40 13.3

+/-1.21 Radium-226 0.547

+/-0.110 Silver-108m U 0.000576

+/-0.0187 Thallium-208 0.268

+/-0.0467 0.0638 0.0698 0.135 0.0369 0.0229 0.0183 0.0191 0.0485 0.0566 0.0533 0.0276 0.0333 0.0201 0.016 0.138 0.0369 0.0163 0.0177

+/-0.160

+/-0.0873

+/-0.304

+1-0.110

+/-0.0423

+/-0.021

+/-0.0226

+/-0.0716

+/-0.0712

+/-0.0615

+/-0.0923

+/-0.102

+/-0.024

+/-0.0195

+/-1.21

+/-0.110

+/-0.0187

+/-0.0467 0.127 0.140 0.271 0.0738 0.0459 0.0366 0.0383 0.097 0.113 0.107 0.0553 0.0666 0.0402 0.0319 0.275 0.0738 0.0326 0.0353 pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g MJHI 10/03/06 1338 574335 1

The following Prep Methods were performed Method Description Analyst Date Time Prep Batch Dry Soil Prep Dry Soil Prep GL-RAD-A-021 JMBI 09/21/06 1745 571421 The following Analytical Methods were performed Method Description 1

EML HASL 300, 4.5.2.3 Notes:

The Qualifiers in this report are defined as follows:

A quality control analyte recovery is outside of specified acceptance criteria Result is less than value reported 78

GENERAL ENGINEERING LABORATORIES, LLC 2040 Savage Road Charleston SC 29407 - (843) 556-8171 - www.gel.com Certificate of Analysis Company:

Connecticut Yankee Atomic Power Address:

362 Injun Hollow Rd East Hampton, Connecticut 06424 Report Date: October 5, 2006

Contact:

Mr. Jack McCarthy Project:

Soils PO# 002332 Client Sample ID:

9807-0000-018FS Project:

YANK01204 Sample ID:

172275020 Client ID:

YANKOOI Vol. Recv.:

Parameter Qualifier Result Uncertainty LC TPU MIDA Units DF Analyst Date Time Batch Mtd Result is greater than value reported A

The TIC is a suspected aldol-condensation product B

Target analyte was detected in the associated blank BD Results are either below the MDC or tracer recovery is low C

Analyte has been confirmed by GC/MS analysis D

Results are reported from a diluted aliquot of the sample H

Analytical holding time was exceeded J

Value is estimated N/A Spike recovery limits do not apply. Sample concentration exceeds spike concentration by 4X or more R

Sample results are rejected U

Analyte was analyzed for, but not detected above the MDL, MDA, or LOD.

UI Gamma Spectroscopy--Uncertain identification X

Consult Case Narrative, Data Summary package,.or Project Manager concerning this qualifier Y

QC Samples were not spiked with this compound A

RPD of sample and duplicate evaluated using +/-RL. Concentrations are <5X the RL h

Preparation or preservation holding time was exceeded The above sample is reported on a dry weight basis.

79

GENERAL ENGINEERING LABORATORIES, LLC 2040 Savage Road Charleston SC 29407 - (843) 556-8171 - www.gel.com Certificate of Analysis Company:

Connecticut Yankee Atomic Power Address 362 Injun Hollow Rd East Hampton, Connecticut 06424

Contact:

Mr. Jack McCarthy Project:

Soils PO# 002332 Report Date: October 5, 2006 Client Sample ID:

9807-0000-019F Project:

YANK01204 Sample ID:

172275021 ClientID:

YANK001 Matrix:

TS Vol. Recv.:

Collect Date:

18-SEP-06 Receive Date:

21-SEP-06 Collector:

Client Moisture:

16.4%

Parameter Qualifier Result Uncertainty LC TPU MDA Units DF Analyst Date Time Batch Mtd Rad Gamma Spec Analysis Gamma,Solid-FSS GAM & ALL FSS 226 Ingrowth Waived Actinium-228 0.781

+/-0.176 0.0467

+/-0.176 0.0998 pCi/g MJHI 10/02/06 1140 574336 1

Americium-241 U

-0.0732

+/-0.111 0.0891

+/-0.111 0.183 pCi/g Bismuth-212 0.448

+/-0.205 0.114

+/-0.205 0.240 pCi/g Bismuth-214 0.550

+/-0.0849 0.0243 +/-0.0849 0.0514 pCi/g Cesium-134 UI 0.00

+/-0.0362 0.0187 +/-0.0362 0.0393 pCi/g Cesium-137 U-0.000324

+/-0.0172 0.0152 +/-0.0172 0.032 pCi/g Cobalt-60 U

0.0165

+/-0.0175 0.0164 +/-0.0175 0.0353 pCi/g Europium-152 U -0.00565

+/-0.0423 0.0372 +/-0.0423 0.0774 pCi/g Europium-154 U

0.0409

+/-0.0545 0.050 44-0.0545 0.107 pCi/g Europium-155 U

0.0304

+/-0.0501 0.0458 +/-0.0501 0.094 pCi/g Lead-212 0.736

+/-0.0767 0.0221 +/-0.0767 0.0456 pCi/g Lead-214 0.535

+/-0.0837 0.0272 +/-0.0837 0.0566 pCi/g Manganese-54 U

0.0163

+/-0.0197 0.0146 +/-0.0197 0.031 pCi/g Niobium-94 U

0.0159

+/-0.0221 0.0155 +/-0.0221 0.0324 pCi/g Potassium-40 13.2

+/-1.16 0.128

+/-1.16 0.280 pCi/g Radium-226 0.550

+/-0.0849.

0.0243 +/-0.0849 0.0514 pCi/g Silver-108m U

0.0141

+/-0.0142 0.013 +/-0.0142 0.0272 pCi/g Thallium-208 0.280

+/-0.0459 0.0121 +/-0.0459 0.0257 pCi/g The following Prep Methods were performed Method Description Analyst Date Time Prep Batch Dry Soil Prep Dry Soil Prep GL-RAD-A-021 JMBI 09/21/06 1749 571423 The following Analytical Methods were performed Method Description EMIL HASL 300,4.5.2.3 Notes:

The Qualifiers in this report are defined as follows:

A quality control analyte recovery is outside of specified acceptance criteria Result is less than value reported 80

GENERAL ENGINEERING LABORATORIES, LLC 2040 Savage Road Charleston SC 29407 - (843) 556-8171 - www.gel.com Certificate of Analysis Company:

Connecticut Yankee Atomic Power Address:

362 Injun Hollow Rd East Hampton, Connecticut 06424 Report Date: October 5, 2006

Contact:

Mr. Jack McCarthy Project:

Soils PO# 002332 Client Sample ID:

9807-0000-019F Project:

YANK01204 Sample ID:

172275021 Client ID:

YANK001 Vol. Recv.:

Parameter Qualifier Result Uncertainty LC TPU MDA Units DF Analyst Date Time Batch Mtd Result is greater than value reported A

The TIC is a suspected aldol-condensation product B

Target analyte was detected in the associated blank BD Results are either below the MDC or tracer recovery is low C

Analyte has been confirmed by GC/MS analysis D

Results are reported from a diluted aliquot of the sample H

Analytical holding time was exceeded J

Value is estimated N/A Spike recovery limits do not apply. Sample concentration exceeds spike concentration by 4X or more R

Sample results are rejected U

Analyte was analyzed for, but not detected above the MDL, MDA, or LOD.

UI Gamma Spectroscopy--Uncertain identification X

Consult Case Narrative, Data Summary package, or Project Manager concerning this qualifier Y

QC Samples were not spiked with this compound A

RPD of sample and duplicate evaluated using +/-RL. Concentrations are <5X the RL h

Preparation or preservation holding time was exceeded The above sample is reported on a dr6 weight basis.

81

GENERAL ENGINEERING LABORATORIES, LLC 2040 Savage Road Charleston SC 29407- (843) 556-8171 - www.gel.com Certificate of Analysis

  • Company:

Connecticut Yankee Atomic Power Address :

362 Injun Hollow Rd East Hampton, Connecticut 06424

Contact:

Mr. Jack McCarthy Project:

Soils PO# 002332 Report Date:

October 5, 2006 Client Sample ID:

Sample ID:

Matrix:

Collect Date:

Receive Date:

Collector:

Moisture:

9807-0000-020F 172275022 TS 18-SEP-06 21-SEP-06 Client 15.3%

Project:

YANK01204 Client ID:

YANK001 Vol. Recv.:

Parameter Qualifier Result Uncertainty LC TPU MDA Units DF Analyst Date Time Batch Mtd Rad Gamma Spec Analysis GammaSolid-FSS GAM & ALL FSS 226 Ingrowth Waived Actinium-228 0.903

+/-0.174 Americium-241 U

0.0644

+/-0.0757 Bismuth-212 0.768

+/-0.253 Bismuth-214 0.500

+/-0.0932 Cesium-134 UI 0.00

+/-0.0427 Cesium-137 U

0.0353

+/-0.0213 Cobalt-60 U

0.00823

+/-0.0247 Europium-152 U

0.00463

+/-0.0538 Europium-154 U

0.00445

+/-0.067 Europium-155 U

0.0843

+/-0.0702 Lead-212 0.904

+/-0.0912 Lead-214 0.599

+/-0.0939 Manganese-54 U

0.0201

+/-0.0415 Niobium-94 U

0.0139

+/-0.0214 Potassium-40 14.1

+/-1.21 Radium-226 0.500

+/-0.0932 Silver-108m U

-0.0173

+/-0.0177 Thallium-208 0.283

+/-0.0422 0.0588 0.071 0.122 0.0321 0.0229 0.0183 0.019 0.0479 0.0576 0.0481 0.0272 0.0341 0.0181 0.0168 0.156 0.0321 0.0144 0.016

+/-0.174

+/-0.0757

+/-0.253

+/-0.0932

+/-0.0427

+/-0.0213

+/-0.0247

+/-0.0538

+/-0.067

+/-0.0702

+/-0.0912

+/-0.0939

+/-0.0415

+/-0.0214

+/-1.21

+/-0.0932

+/-0.0177

+/-0.0422 0.127 0.145 0.262 0.068 0.0484 0.0388 0.0415 0.100 0.125 0.0992 0.0563 0.0713 0.0385 0.0355 0.347 0.068 0.0305 0.0339 pCi/g pCi/g pCi/g pCi/g pCi/g pCitg pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g MJHI 10/02/06 1342 574336 1

The following Prep Methods were performed Method Description Analyst Date Time Prep Batch Dry Soil Prep

.. Dry Soil Prep GL-RAD-A-021 JMB1 09/21/06 1749 571423 The following Analytical Methods were performed Method Description I

EML HASL 300, 4.5.2.3 Notes:

The Qualifiers in this report are defined as follows:

A quality control analyte recovery is outside of specified acceptance criteria Result is less than value reported 82

GENERAL ENGINEERING LABORATORIES, LLC 2040 Savage Road Charleston SC 29407 - (843) 556-8171 - www.gel.com Certificate of Analysis Company:

Connecticut Yankee Atomic Power Address :

362 Injun Hollow Rd East Hampton, Connecticut 06424 Report Date: October 5, 2006

Contact:

Mr. Jack McCarthy Project:

Soils PO# 002332 Client Sample ID:

9807-0000-020F Proiect:

YANK01204 Sample ID:

172275022 Client ID:

YANK001 Vol. Recv.:

Parameter Qualifier Result Uncertainty LC TPU MDA Units DF Analyst Date Time Batch Mtd Result is greater than value reported A

The TIC is a suspected aldol-condensation product B

Target analyte was detected in the associated blank BD Results are either below the MDC or tracer recovery is low C

Analyte has been confirmed by GC/MS analysis D

Results are reported from a diluted aliquot of the sample H. Analytical holding time was exceeded J

Value is estimated N/A Spike recovery limits do not apply. Sample concentration exceeds spike concentration by 4X or more R

Sample results are rejected U

Analyte was analyzed for, but not detected above the MDL, MDA, or LOD.

UI Gamma Spectroscopy-Uncertain identification X

Consult Case Narrative, Data Summary package, or Project Manager concerning this qualifier Y

QC Samples were not spiked with this compound A

RPD of sample and duplicate evaluated using +/-RL. Concentrations are <5X the RL h

Preparation or preservation holding time was exceeded The above sample is reported on a dry weight basis.

83

GENERAL ENGINEERING LABORATORIES, LLC 2040 Savage Road Charleston SC 29407 - (843) 556-8171 - www.gel.com Certificate of Analysis Company:

Connecticut Yankee Atomic Power Address:

362 Injun Hollow Rd East Hampton, Connecticut 06424

Contact:

Mr. Jack McCarthy Project:

Soils PO# 002332 Report Date: October 5, 2006 Client Sample ID:

Sample ID:

Matrix:

Collect Date:

Receive Date:

Collector:

Moisture:

Parameter Qualifier Result U

Rad Gamma Spec Analysis Gamma,Solid-FSS GAM & ALL FSS 226 Ingrowth Waived Actinium-228 0.804 Americium-241 U

0.00322 Bismuth-212 U

0.341 Bismuth-214 0.573 Cesium-134 U

0.0536 Cesium-137 UI 0.00 Cobalt-60 U

-0.026 Europium-152 U

0.0168 Europium-154 U

0.0284 Europium-155 Ul 0.00 Lead-212 0.605 Lead-214 0.597 Manganese-54 U

0.0308 Niobium-94 U.- 0.0104 Potassium-40 11.8 Radium-226 0.573 Silver-108m U

0.00472 Thallium-208 0.217 9807-0000--021F 172275023 TS 18-SEP-06 2 1-SEP-06 Client 14.2%

Proiect:

YANK01204 Client ID:

YANK001 Vol. Recv.:

ncertalnty LC TPU MDA Units DF Analyst Date Time Batch Mtd

+/-0.168

+/-0.0321

+/-0.296

+/-0.0993

+/-0.0434

+/-0.0652

+/-0.0285

+/-0.0573

+/-0.0712

+/-0.0795

+/-0.0705

+/-0.0881

+/-0.0275

+/-0.021

+/- 1.02

+/-0.0993

+/-0.0192

+/-0.0616 0.0754 0.0295 0.169 0.0365 0.0277 0.0212 0.0219 0.0505 0.0628 0.0449 0.0398 0.0356 0.0227 0.0175 0.189 0.0365 0.0176 0.0209

+/-0.168

+/-0.0321

+/-0.296

+/-0.0993

+/-0.0434

+/-0.0652

+/-0.0285

+/-0.0573

+/-0.0712

+/-0.0795

+/-0.0705

+/-0.0881

+/-0.0275

+/-0.021

+/-1.02

+/-0.0993

+/-0.0192

+/-0.0616 0.161 0.0607 0.357 0.0772 0.0582 0.0448 0.0474 0.106 0.136 0.0928 0.0817 0.0744 0.048 0.0371 0.415 0.0772 0.0371 0.044 pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g MJHI 10/02/06 1342 574336 1

The following Prep Methods were performed Method Description Analyst Date Time PrepBatch Dry Soil Prep Dry Soil Prep GL-RAD-A-021 JMBI 09/21/06 1749 571423 The following Analytical Methods were performed Method Description EML HASL 300, 4.5.2.3 Notes:

The Qualifiers in this report are def'ied as follows:

A quality control analyte recovery is outside of specified acceptance criteria Result is less than value reported 84

GENERAL ENGINEERING LABORATORIES, LLC 2040 Savage Road Charleston SC 29407 - (843) 556-8171 - www.gel.com Certificate of Analysis Company:

Connecticut Yankee Atomic Power Address :

362 Injun Hollow Rd East Hampton, Connecticut 06424 Report Date: October 5, 2006

Contact:

Mr. Jack McCarthy Project:

Soils PO# 002332 Client Sample ID:

9807-0000-021F Project:

YANK01204 Sample ID:

172275023 Client ID:

YANK001 Vol. Recv.:

Parameter Qualifier Result Uncertainty LC TPU MDA Units DF Analyst Date Time Batch Mtd Result is greater than value reported A

The TIC is a suspected aldol-condensation product B

Target analyte was detected in the associated blank BD Results are either below the MIDC or tracer recovery is low C

Analyte has been confirmed by GC/MS analysis D

Results are reported from a diluted aliquot of the sample H

Analytical holding time was exceeded J

Value is estimated N/A Spike recovery limits do not apply. Sample concentration exceeds spike concentration by 4X or more R

Sample results are rejected U

Analyte was analyzed for, but not detected above the MDL, MDA, or LOD.

UI Gamma Spectroscopy--Uncertain identification X

Consult Case Narrative, Data Summary package, or Project Manager concerning this qualifier Y

QC Samples were not spiked with this compound A

RPD of sample and duplicate evaluated using +/-RL. Concentrations are <5X the RL h

Preparation or preservation holding time was exceeded The above sample is reported on a dry weight basis.

85

GENERAL ENGINEERING LABORATORIES, LLC 2040 Savage Road Charleston SC 29407 - (843) 556-8171 - www.gel.com Certificate of Analysis Company:

Connecticut Yankee Atomic Power Address :

362 Injun Hollow Rd........

Contact:

Project:

East Hampton, Connecticut 06424 Mr. Jack McCarthy Soils PO# 002332 Report Date: October 5, 2006 Client Sample ID:

Sample ID:

Matrix:

Collect Date:

Receive Date:

Collector:

Moisture:

9807-0000-022F 172275024 TS 14-SEP-06 21 -SEP-06 Client 12.7%

Project:

YANK01204 Client ID:

YANK001 Vol. Recv.:

Parameter Qualifier Result Uncertainty LC TPU MDA Units DF Analyst Date Time Batch Mtd Rad Gamma Spec Analysis Gamnnia,Solid-FSS GAM & ALL FSS 226 Ingrowth Waived Actinium-228 0.768

+/-0.137 Americium-241 U

0.040

+/-0.104 Bismuth-212 0.533

+/-0.205 Bismuth-214 0.569

+/-0.0753 Cesium-134 Ut 0.00

+/-0.023 Cesium-137 U

0.0288

+/-0.0254 Cobalt-60 U

0.0109

+/-0.0158 Europium-152 U -0.00332

+/-0.0447 Europium-154 U

-0.0303

+/-0.0481 Europium-155 U

0.0221

+/-0.0517 Lead-212 0.813

+/-0.0536 Lead-214 0.604

+/-0.0652 Manganese-54 U

-0.0119

+/-0.0153 Niobium-94 U

0.00375

+/-0.0147 Potassium-40 13.8

+/-0.766 Radium-226 0.569

+/-0.0753 Silver-108m U

0.0117

+/-0.0139 Thallium-208 0.257

+/-0.0386 0.0508 0.0846 0.103 0.0272 0.0168 0.0144 0.0145 0.0351 0.0393 0.0485 0.0216 0.025 0.0125 0.0132 0.124 0.0272 0.0128 0.0133

+/-0.137

+/-0.104

+/-0.205

+/-0.0753

+/-0.023

+/-0.0254

+/-0.0158

+/=0.0447

+/-0.0481

+/-0.0517

+/-0.0536

+/-0.0652

+/-0.0153

+/-0.0147

+/-0.766

+/-0.0753

+/-0.0139

+/-0.0386 0.108 0.175 0.219 0.0571 0.0355 0.0303 0.0312 0.0734 0.0849 0.100 0.0449 0.0524 0.0266 0.0277 0.271 0.0571 0.0267 0.0279 pCi/g pCilg pCi/g pCilg pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCUg pCi/g pCi/g pCi/g pCi/g MJHI 10/02/06 1343 574336 1

The following Prep Methods were performed Method Description Analyst Date Time Prep Batch Dry Soil Prep Dry Soil Prep GL-RAD-A-021 JMBI 09/21/06 1749 571423 The following Analytical Methods were performed Method Description 1

EML HASL 300,4.5.2.3 Notes:

The Qualifiers in this report are defined as follows:

A quality control analyte recovery is outside of specified acceptance criteria Result is less than value reported 86

GENERAL ENGINEERING LABORATORIES, LLC 2040 Savage Road Charleston SC 29407 - (843) 556-8171 - www.gel.com Certificate of Analysis Company:

Connecticut Yankee Atomic Power Address:

362 Injun Hollow Rd East Hampton, Connecticut 06424 Report Date: October 5, 2006

Contact:

Mr. Jack McCarthy Project:

Soils PO# 002332 Client Sample ID:

9807-0000-022F Project:

YANK01204 Sample ID:

172275024 Client ID:

YANK001 Vol. Recv.:

Parameter Qualifier Result Uncertainty LC TPU MDA Units DF Analyst Date Time Batch Mtd Result is greaterthan value reported A

The TIC is a suspected aldol-condensation product B

Target analyte was detected in the associated blank BD Results are either below the MDC or tracer recovery is low C

Analyte has been confirmed by GC/MS analysis D

Results are reported from a diluted aliquot of the sample H

Analytical holding time was exceeded J

Value is estimated N/A Spike recovery limits do not apply. Sample concentration exceeds spike concentration by 4X or more R

Sample results are rejected U

Analyte was analyzed for, but not detected above the MDL, MDA, or LOD.

UI Gamma Spectroscopy-Uncertain identification X

Consult Case Narrative, Data Summary package, or Project Manager concerning this qualifier Y

QC Samples were not spiked with this compound A

RPD of sample and duplicate evaluated using +/-RL. Concentrations are <5X the RL h

Preparation or preservation holding time was exceeded The above sample is reported on a dry weight basis.

87

GENERAL ENGINEERING LABORATORIES, LLC 2040 Savage Road Charleston SC 29407 - (843) 556-8171 - www.gel.com Certificate of Analysis Company : Connecticut Yankee Atomic Power Address:

362 Injun Hollow Rd East Hampton, Connecticut 06424

Contact:

Mr. Jack McCarthy Project:

Soils PO# 002332 Report Date:

October 5, 2006 Client Sample ID:

Sample ID:

Matrix:

Collect Date:

Receive Date:

Collector:

9807-0000-023F 172275025 TS 18-SEP-06 21-SEP-06 Client Proiect:

YANK01204 Client ID:

YANK001 Vol. Recv.:

Parameter Qualifier Result Uncertainty LC TPU MDA Units DF Analyst Date Time Batch Mtd Rad Gamma Spec Analysis Gamma,Solid-FSS GAM & ALL FSS 226 Jngrowth Waived Actinium-228 Americium-241 Bismuth-212 Bismuth-214 Cesium-134 Cesium-137 Cobalt-60 Europium-152 Europium-154 Europium-155 Lead-212 Lead-214 Manganese-54 Niobium-94 Potassium-40 Radium-226 Silver-108m Thallium-208 0.672 U -0.00365 0.548 0.488 UI 0.00 0.0256 U -0.00147 U

-0.0189 U

-0.0143 U

0.0701 0.699 0.564 U

0.0035 U

0.008 13.1 0.488 U

-0.0015 0.214

+/-0.128

+/-0.0563

+/-0.201

+/-0.0713

+/-0.0277

+/-0.0242

+/-0.0139

+1-0.0344

+/-0.0401

+/-0.0625

+/-0.0454

+/-0.0661

+/-0.0129

+/-0.0121

+/-0.645

+/-0.0713

+/-0.0115

+/-0.0277 0.0409 0.0487 0.0816 0.0212 0.0158 0.011 0.0115 0.0304 0.0326 0.0379 0.0228 0.0215 0.0116 0.0113 0.074 0.0212 0.0102 0.0111

+/-0.128

+/-0.0563

+/-0.201

+/-0.0713

+/-0.0277

+/-0.0242

+/-0.0139

+/-0.0344

+/-0.0401

+/-0.0625

+/-0.0454

+/-0.0661

+/-0.0129

+/-0.0121

+/-0.645

+/-0.0713

+/-0.0115

+/-0.0277 0.0868 0.100 0.173 0.0446 0.0331 0.0233 0.0249 0.0634 0.0702 0.078 0.0468 0.0448 0.0245 0.0236 0.166 0.0446 0.0213 0.0233 pCi/g pCi/g pCi/g pCi/g pCilg pCi/g pCi/g pCi/g pCi/g pCi/g pCilg pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g MJHI 10/02/06 1343 574336 1

The following Prep Methods were performed Method Description Analyst Date Time Prep Batch Dry Soil Prep Dry Soil Prep GL-RAD-A-021 JiB 1 09/21/06 1749 571423 The following Analytical Methods were performed Method Description I

EMIL HASL 300,4.5.2.3 Notes:

The Qualifiers in this report are defined as follows:

A quality control analyte recovery is outside of specified acceptance criteria Result is less than value reported 88

GENERAL ENGINEERING LABORATORIES, LLC 2040 Savage Road Charleston SC 29407 - (843) 556-8171 - www.gel.comn Certificate of Analysis Company:

Connecticut Yankee Atomic Power Address :

362 Injun Hollow Rd East Hampton, Connecticut 06424 Report Date: October 5, 2006

Contact:

Mr. Jack McCarthy Project:

Soils PO# 002332 Client Sample ID:

9807-0000-023F Proiect:

YANKO01204 Sample ID:

172275025 Client ID:

YANK001 Vol. Recv.:

Parameter Qualifier Result Uncertainty LC TPU MDA Units DF Analyst Date Time Batch Mtd Result is greater than value reported A

The TIC is a suspected aldol-condensation product B

Target analyte was detected in the associated blank BD Results are either below the MDC or tracer recovery is low C

Analyte has been confirmed by GC/MS analysis D

Results are reported from a diluted aliquot of the sample H

Analytical holding time was exceeded J

Value is estimated N/A Spike recovery limits do not apply. Sample concentration exceeds spike concentration by 4X or more R

Sample results are rejected U

Analyte was analyzed for, but not detected above the MDL, MDA, or LOD.

UI Ganmma Spectroscopy-Uncertain identification X

Consult Case Narrative, Data Summary package, or Project Manager concerning this qualifier Y

QC Samples were not spiked with this compound A

RPD of sample and duplicate evaluated using +/-RL. Concentrations are <5X the RL h

Preparation or preservation holding time was exceeded The above sample is reported on a dry weight basis.

89

GENERAL ENGINEERING LABORATORIES, LLC 2040 Savage Road Charleston SC 29407 - (843) 556-8171 - www.gel.com Certificate of Analysis Company:

Connecticut Yankee Atomic Power Address :

362 Injun Hollow Rd........

East Hampton, Connecticut 06424

Contact:

Mr. Jack McCarthy Project:

Soils PO# 002332 Report Date:

October 5, 2006 Client Sample ID:

Sample ID:

Matrix:

Collect Date:

Receive Date:

Collector:

Moisture:

9807-0000-024F 172275026 TS 18-SEP-06 21-SEP-06 Client 16.2%

Proiect:

YANK01204 Client ID:

YANK001 Vol. Recv.:

Parameter Qualifier Result Uncertainty LC TPU MDA Units DF Analyst Date Time Batch Mtd Rad Gamma Spec Analysis Gamma,Solid-FSS GAM & ALL FSS 226 Ingrowth Waived Actinium-228 0.755

+/-0.141 Americium-241 U -0.00337

+/-0.113 Bismuth-212 0.520

+/-0.195 Bismuth-214 0.498

+/-0.074 Cesium-134 U

0.0263

+/-0.0258 Cesium-137 U

0.0118

+/-0.0306 Cobalt-60 U

0.00876

+/-0.0288 Europiurn-152 U

-0.0197

+/-0.0448 Europium-154 U

-0.035

+/-0.051 Europiurn-155 U

0.0896

+/-0.0847 Lead-212 0.679

+/-0.0775 Lead-214 0.518

+/-0.0749 Manganese-54 U

0.0111

+/-0.0156 Niobium-94 U -0.00861

+/-0.015 Potassiumn-40 12.1

+/-1.08 Radium-226 0.498

+/-0.074 Silver-108m U

-0.013

+/-0.0145 Thallium-208 0.282

+/-0.0417 0.0509 0.0931 0.118 0.0235 0.0187 0.0149 0.0171 0.0388 0.0415 0.0448 0.025 0.0278 0.0152 0.0127 0.158 0.0235 0.0119 0.0155

+/-0.141

+/-0.113

+/-0.195

+/-0.074

+/-0.0258

+/-0.0306

+/-0.0288

+/-0.0448

+/-0.051

+/-0.0847

+/-0.0775

+/-0.0749

+/-0.0156

+/-0.015

+/-1.08

+/-0.074

+/-0.0145

+/-0.0417 0,108 0.191 0.248 0.0497 0.0393 0.0314 0.0368 0.0806 0.0899 0.092 0.0514 0.0578 0.0321 0.0268 0.342 0.0497 0.025 0.0325 pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCilg pCilg pCi/g pCi/g pCi/g pCilg pCi/g pCi/g pCi/g pCi/g MJH1 10/02/06 1502 574336 1

The following Prep Methods were performed Method Description Analyst Date Time Prep Batch Dry Soil Prep Dry Soil Prep GL-RAD-A-021 JMB I 09/21/06 1749 571423 The following Analytical Methods were performed Method Description I

EML HASL 300, 4.5.2.3 Notes:

The Qualifiers in this report are defined as follows:

A quality control analyte recovery is outside of specified acceptance criteria Result is less than value reported 90

GENERAL ENGINEERING LABORATORIES, LLC 2040 Savage Road Charleston SC 29407 - (843) 556-8171 - www.gel.com Certificate of Analysis Company:

Connecticut Yankee Atomic Power Address :

362 Injun Hollow Rd East Hampton, Connecticut 06424 Report Date: October 5, 2006

Contact:

Mr. Jack McCarthy Project:

Soils PO# 002332 Client Sample ID:

9807-0000-024F Project:

YANK01204 Sample ID:

172275026 Client ID:

YANKOO0 Vol. Recv.:

Parameter Qualifier Result Uncertainty LC TPU MDA Units DF Analyst Date Time Batch Mtd Result is greater than value reported A

The TIC is a suspected aldol-condensation product B

Target analyte was detected in the associated blank BD Results are either below the MDC or tracer recovery is low C

Analyte has been confirnmed by GC/MS analysis D

Results are reported from a diluted aliquot of the sample H

Analytical holding time was exceeded J

Value is estimated N/A Spike recovery limits do not apply. Sample concentration exceeds spike concentration by 4X or more R

Sample results are rejected U

Analyte was analyzed for, but not detected above the MDL, MDA, or LOD.

UI Gamma Spectroscopy--Uncertain identification X

Consult Case Narrative, Data Summary package, or Project Manager concerning this qualifier Y

QC Samples were not spiked with this compound A

RPD of sample and duplicate evaluated using +/-RL. Concentrations are <5X the RL h

Preparation or preservation holding time was exceeded The above sample is reported on a dry weight basis.

91

GENERAL ENGINEERING LABORATORIES, LLC 2040 Savage Road Charleston SC 29407 - (843) 556-8171 - www.gel.com Certificate of Analysis Company : Connecticut Yankee Atomic Power Address :

362 Injun Hollow Rd East Hampton, Connecticut 06424

Contact:

Mr. Jack McCarthy Project:

Soils PO# 002332 Report Date: October 5, 2006 Client Sample ID:

Sample ID:

Matrix:

Collect Date:

Receive Date:

Collector:

Moisture:

9807-0000-024FS 172275027 TS 18-SEP-06 21-SEP-06 Client 16.9%

Proiect:

YANK01204 Client ID:

YANK001 Vol. Recv.:

Parameter Qualifier Result Uncertainty LC TPU MDA Units DF Analyst Date Time Batch Mtd Rad Gamma Spec Analysis GammaSolid-FSS GAM & ALL FSS 226 Ingrowth Waived Actinium-228 0.888.

+/-0.160 Americium-241 U -0.00511

+/-0.0266 Bismuth-212 0.445

+/-0.344 Bismuth-214 0.652

+/-0.0902 Cesium-134 U

0.0396

+/-0.0287 Cesium-137 U

0.00396

+/-0.0217 Cobalt-60 U

0.0056

+/-0.0266 Europium-152 U -0.00788

+/-0.0485 Europium-154 U

-0.0118

+/-0.0725 Europium-155 U

0.0372

+/-0.0537 Lead-212 0.809

+/-0.0568 Lead-214 0.636

+/-0.0814 Manganese-54 U

0.00309

+/-0.0214 Niobium-94 U

0.0104

+/-0.0189 Potassium-40 13.6

+/-0.935 Radium-226 0.652

+/-0.0902 Silver-108m U -0.00209

+/-0.016 Thallium-208 0.287

+/-0.048 0.0592 0.0232 0.127 0.0265 0.0245 0.0188 0.0228 0.0406 0.0599 0.0381 0.0238 0.0266 0.0181 0.0168 0.154 0.0265 0.0142 0.0166

+/-0.160

+/-0.0266

+/-0.344

+/-0.0902

+/-0.0287

+/-0.0217

+/-0.0266

+/-0.0485

+/-0.0725

+/-0.0537

+/-0.0568

+/-0.0814

+/-0.0214

+/-0.0189

+/-0.935

+/-0.0902

+/-0.016

+/-0.048 0.128 0.0477 0.274 0.057 0.0519 0.040 0.0494 0.0855 0.130 0.0788 0.0495 0.0563 0.0388 0.0357 0.347 0.057 0.030 0.0354 pCi/g pCi/g pCilg pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g MJHI 10/02/06 1502 574336 1

The following Prep Methods were performed Method Description Analyst Date Time Prep Batch Dry Soil Prep Dry Soil Prep GL-RAD-A-021 JMIBI 09/21/06 1749 571423 The following Analytical Methods were performed Method Description I

EML HASL 300, 4.5.2.3 Notes:

The Qualifiers in this report are defined as follows:

A quality control analyte recovery is outside of specified acceptance criteria Result is less than value reported 92

GENERAL ENGINEERING LABORATORIES, LLC 2040 Savage Road Charleston SC 29407 - (843) 556-8171 - www.gel.com Certificate of Analysis Company Connecticut Yankee Atomic Power Address:

362 Injun Hollow Rd East Hampton, Connecticut 06424 Report Date: October 5, 2006

Contact:

Mr. Jack McCarthy Project:

Soils PO# 002332 Client Sample ID:

9807-0000-024FS Proiect:

YANK01204 Sample ID:

172275027 Client ID:

YANKOOI Vol. Recv.:

Parameter Qualifier Result Uncertainty LC TPU MDA Units DF Analyst Date Time Batch Mtd Result is greater than value reported A

The TIC is a suspected aldol-condensation product B

Target analyte was detected in the associated blank BD Results are either below the MDC or tracer recovery is low C

Analyte has been confirmed by GC/MS analysis D

Results are reported from a diluted aliquot of the sample H

Analytical holding time was exceeded J

Value is estimated N/A Spike recovery limits do not apply. Sample concentration exceeds spike concentration by 4X or more R

Sample results are rejected U

Analyte was analyzed for, but not detected above the MDL, MDA, or LOD.

UI Gamma Spectroscopy--Uncertain identification X

Consult Case Narrative, Data Summary package, or Project Manager concerning this qualifier Y

QC Samples were not spiked with this compound A

RPD of sample and duplicate evaluated using +/-RL. Concentrations are <5X the RL h

Preparation or preservation holding time was exceeded The above sample is reported on a dry weight basis.

93

GENERAL ENGINEERING LABORATORIES, LLC 2040 Savage Road Charleston SC 29407 - (843) 556-8171 - www.gel.corn Certificate of Analysis Company:

Connecticut Yankee Atomic Power Address:

362 Injun Hollow Rd East Hampton, Connecticut 06424

Contact:

Mr. Jack McCarthy Project:

Soils PO# 002332 Report Date: October 5, 2006 Client Sample ID:

Sample ID:

Matrix:

Collect Date:

Receive Date:

Collector:

9807-0000-025F 172275028 TS 18-SEP-06 2 1-SEP-06 Client Proiect:

YANK01204 Client ID:

YANK001 Vol. Recv.:

oVt s bLUI I.

1/70 Parameter Qualifier Result Uncertainty LC TPU MDA Units DF Analyst Date Time Batch Mtd Rad Gamma Spec Analysis Ganima,Solid-FSS GAM & ALL FSS 226 Ingrowth Waived Actinium-228 0.575

+/-0.137 Americium-24t U-0.000377

+/-0.0553 Bismuth-212 0.487

+/-0.229 Bismuth-214

  • 0.606

+/-0.0922 Cesium-134 U

0.027

+/-0.0188 Cesium-137 3.50

+/-0.317 Cobalt-60 0.089

+/-0.0294 Europium-152 U

-0.0197

+/-0.049 Europium-154 U -0.0211

+/-0.0462 Europium-155 U

0.0382

+/-0.0686 Lead-212 0.583

+/-0.066 Lead-214 0.695

.+/-0.107 Manganese-54 U

0.0169

+/-0.0161 Niobium-94 U -0.00138

+/-0.0123 Potassium-40 9.02

+/-0.922 Radium-226 0.606

+/-0.0922 Silver-108m U

-0.0159

+/-0.0205 Thallium-208 0.186

+/-0.0436,/

0.0443 0.0502 0.0981 0.0315 0.018 0.0156 0.0116 0.042 0.038 0.0412 0.0234 0.0316 0.015 0.0107 0.121 0.0315 0.0168 0.0154

+/-0.137

+/-0.0553

+/-0.229

+4-0.0922 4/-0.0188

+/-0.317

+/-0.0294

+/-0.049

+/-0.0462

+/-0.0686

+/-0.066

+/-0.107

+/-0.0161

+/-0.0123

+/-0.922

+/-0.0922

+/-0.0205

+/-0.0436 0.0963 0.104 0.211 0.0663 0.0382 0.0332 0.0262 0.0877 0.0839 0.0852 0.0484 0.0658 0.0321 0.0231 0.271 0.0663 0.035 0.0325 pCi/g pCi/g pCi/g pCi/g pCi/g.

pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g MJH 1 10/02/06 1502 574336 1

The following Prep Methods were performed Method Description Analyst Date Time Prep Batch Dry Soil Prep Dry Soil Prep GL-RAD-A-021 JMBI

.09/21/06 1749 571423 The following Analytical Methods were performed Method Description 1

EML HASL 300,4.5.2.3 Notes:

The Qualifiers in this report are defined as follows:

A quality control analyte recovery is outside of specified acceptance criteria Result is less than value reported 94

GENERAL ENGINEERING LABORATORIES, LLC 2040 Savage Road Charleston SC 29407 - (843) 556-8171 - www.gel.com Certificate of Analysis Company:

Connecticut Yankee Atomic Power Address:

362 Injun Hollow Rd East Hampton, Connecticut 06424 Report Date: October 5, 2006

Contact:

Mr. Jack McCarthy Project:

Soils PO# 002332 Client Sample ID:

9807-0000-025F Project:

YANK01204 Sample ID:

172275028 Client ID:

YANK001 Vol. Recv.:

Parameter Qualifier Result Uncertainty LC TPU MDA Units DF Analyst Date Time Batch Mtd Result is greater than value reported A

The TIC is a suspected aldol-condensation product B

Target analyte was detected in the associated blank BD Results are either below the MDC or tracer recovery is low C

Analyte has been confirmed by GC/MS analysis D

Results are reported from a diluted aliquot of the sample H

Analytical holding time was exceeded J

Value is estimated N/A Spike recovery limits do not apply. Sample concentration exceeds spike concentration by 4X or more R

Sample results are rejected U

Analyte was analyzed for, but not detected above the MDL, MDA, or LOD.

UI Gamma Spectroscopy--Uncertain identification X

Consult Case Narrative, Data Summary package, or Project Manager concerning this qualifier Y

QC Samples were not spiked with this compound A

RPD of sample and duplicate evaluated using +/-RL. Concentrations are <5X the RL h

Preparation or preservation holding time was exceeded The above sample is reported on a dry weight basis.

95

.1 QUALITY CONTROL DATA 1.

96

GENERAL ENGINEERING LABORATORIES, LLC 2040 Savage Road Charleston SC 29407 - (843) 556-8171 - www.gel.com QC Summary Client :

Connecticut Yankee Atomic Power 362 Injun Hollow Rd Revort Date: October 5, 2006 Page 1 of 12 East Hampton, Connecticut

Contact:

Mr. Jack McCarthy Workorder:

172275 Parmname NOM Sample Qual QC Units RPD%

REC%

Range Anlst Date Time Rad Alpha Spec Batch 572120 QC1201191304 Americium-241 Curium-242 Curium-243/244 QC1201191306 Americium-241 Curium-242 Curium-243/244 QC1201191303 Amnericium-241 172114001 DUP U

0.0864 Uncert:

+/-0.105 TPU:

+/-0.106 U

0.00 Uncert:

+/-0.0553 TPU:

+/-0.0553 U

0.0664 Uncert:

+/-0.0911 TPU:

+/-0.0915 LCS MB 11.4 Uncert:

TPU:

Uncert:

TPU:

13.7 Uncert:

TPU:

Uncert:

TPU:

Uncert:

TPU:

Uncert:

TPU:

U 0.0286

+/-0.0554

+/-0.0555 U

-0.0072

+/-0.0141

+/-0.0141 U

-0.00672

+/-0.0132

+/-0.0132 12.6

+/-1.20

+/-1.96 U

0.0299

+/-0.0586

+1-0.0588 14.4

+/-1.28

+/-2.18 U

0.00455

+/-0.0226

+/-0.0227 U

0.00

+/-0.0581

+/-0.0581 U

-0.0704

+/-0.0436

+/-0.0445 pCi/g 101 (0% - 100%)

TCI 09/28/06 11:56 Curium-242 PCi/g Pqi/g PCi/g PCi/g pCi/g pCilg PCi/g pCi/g pCi/g 105 (75%-125%)

pCi/g 200 (0%- 100%)

pCi/g 245 (0%- 100%)

111 (75%-125%)

Curium-243/244 QCI201191305 Americium-241 172114001 MS Curium-242 12.0 Uncert:

TPU Uncert:

TPU 14.5 Uncert:

TPU U

0.0864

+1-0.105

+/-0.106 U

0.00

+/-0.0553

+/-0.0553 U

0.0664

+/-0.0911

+/-0.0915 U

12.9

+/-1.10

+/-1.85

-0.0126

+/-0.0175

+/-0.0175 14.4

+/-1.16

+/-2.03 108 (75%-125%)

Curium-243/244 99 (75%-125%)

Batch 572121 QC1201191308 172114001 DUP Plutonium-238 U

0.102 U

0.0358 pCi/g 96 (0%- 100%)

TCI 09/28/06 11:56 97

GENERAL ENGINEERING LABORATORIES, LLC 2040 Savage Road Charleston SC 29407 - (843) 556-8171 - www.gel.com QC Summary Workorder:

172275 Page 2 of 12 Parmname NOM Sample Qual QC Units RPD%

REC%

Range Arist Date Time Rad Alpha Spec Batch 572121 Plutonium-239/240 QC1onum20193108 Plutonium-239/4 QC 1201191307 NIB Plutonium-238 Plutoniurn-239/240 QC1201191309 172114001 MS Plutonium-238 PILutoniuni-239/240 Uncert:

TPU:

U Uncert:

TPU:

Uncert:

TPU:

10.5 Uncert:

TPU:

Uncert:

TPU:

Uncert:

TPU:

U Uncert:

TPU:

11.1 U

Uncert:

TPU:

+/-0.0996

+/-0.100 0.062

+/-0.077

+/-0.0773

+/-0.0808

+/-0.0809 U

-0.0313

+/-0.0909

+/-0.091 U

0.0404

+1-0.0758

+/-0.0759 11.2

+/-1.07

+/-1.73 U

0.00363

+/-0.114

+/-0.114 U

0.0618

+/-0.107

+/-0.107 pCi/g 608 (0%- 100%)

pCi/g pCi/g pCi/g pCi/g pCi/g PCi/g (75%-125%)

107 (75%-125%)

09/28/06 11:56 0.102

+/-0.0996

+/-0.100 0.062

+/-0.077

+/-0.0773 U

0.0976

+/-0.102

+/-0.103 11.9

+/-1.09

+/-1.79 (750%-125%)

09/28/06 11:56 107 (75%-125%)

Batch 572122 QC1201191312 172114001 DUP Plutonium-241 QC120I 191314 LCS Plutonium-241 QC1201191311 MB Plutonium-241 QC1201191313 172114001 MS Plutonium-241 Rad Gamma Spec Batch 574335 QC1201196537 172275001 DUP Actinium-228 U

6.10 Uncert:

+/-8.99 TPU:

+/-9.01 U

4.20

+/-8.54

+/-8.55 pCi/g 0

(0%- 100%)

TCI 09/29/06 23:34 132 Uncert:

TPU:

Uncert:

TPU:

112

+/-12.9

+/-17.0 U

2.21

+/-8.86

+/-8.86 pCi/g pCi/g pCi/g 85 (75%-125%)

98 (75%-125%)

09/30/06 00:06 09/29/06 23:18 09/29/06 23:50 144 U

Uncert:

TPU:

6.10

+/-8.99

+/-9.01 0.917

+/-0.197 141

  • +/-14.2

+/-19.8 0.812

+/-0.158

+/-0.158 pCi/g 12 (0% - 100%) MJH1 10/03/06 15:37 Uncert:

98

GENERAL ENGINEERING LABORATORIES, LLC 2040 Savage Road Charleston SC 29407 - (843) 556-8171 - www.gel.com Workorder:

172275 Parnname QC Summary Page 3 of 12 Sample Oual OC Units RPD%

REC%

Ranme Anist Date Time NOM Rad Gamma Spec Batch 574335 Americium-241 Bismuth-212 Bismuth-214 Cesium-134 Cesium-137 Cobalt-60 Europium-152 Europium-154 Europium-155 Lead-212 Lead-214 Manganese-54 Niobium-94 Potassium-40 Radium-226 Silver-108m TPU:

+/-0.197 U

0.0336; U

-0.0128 Uncert:

+/-0.0304

+/-0.111 TPU:

+/-0.0304

+/-0.111 0.332 0.683 Uncert:

+/-0.297

+/-0.354 TPU:

+/-0.297

+/-0.354 0.594 0.535 Uncert:

+/-0.0918

+/-0.115 TPU:

+/-0.0918

+/-0.115 U

0.0178 UI 0.00 Uncert:

+/-0.0337

+/-0.0427 TPU:

+/-0.0337

+/-0.0427 U

-0.00791 U

0.00068 Uncert:

+/-0.0231

+/-0.026 TPU:

+/-0.0231

+/-0.026 U

-0.032 U

0.0131 Uncert:

+/-0.0272

+/-0.0256 TPU:

+/-0.0272

+/-0.0256 U

0.00865 U

-0.0158 Uncert:

+/-0.0526

+/-0.0636 TPU:

+/-0.0526

+/-0.0636 U

-0.00226 U

-0.00675 Uncert:

+/-0.0668

+/-0.0738 TPU:

+/-0.0668

+/-0.0738 U

0.0769 U

0.0493 Uncert:

+/-0.0755

+/-0.0876 TPU:

+/-0.0755

+/-0.0876 0.826 0.826 Uncert:

+/-0.0631

+/-0.0726 TPU:

+/-0.0631

+/-0.0726 0.596 0.633 Uncert:

+/-0.0873

+/-0.106 TPU:

+/-0.0873

+/-0.106 U

-0.00108 U

0.00343 Uncert:

+/-0.0247

+/-0.0231 TPU:

+/-0.0247

+/-0.0231 U

-0.00289 U

0.00591 Uncert:

+/-0.021

+/-0.0228 TPU:

+/-0.021

+/-0.0228 12.6 14.3 Uncert:

+/-0.924

+-/-1.11 TPU:

+/-0.924

+/- 1.11 0.594 0.535 Uncert:

+/-0.0918

+/-0.115 TPU:

+1-0.0918

+/-0.115 U

0.00205 U

0.0158 Uncert:

+/-0.0182

+/-0.0215 pCi/g 445 pCi/g 69 pCi/g 10 pCig 121 pCi/g 238 pCi/g 478 pCi/g 685 pCi/g 100 pCi/g 44 pCi/g 0

pCi/g 6

pCi/g 384 pCi/g 584 pCi/g 13 pCi/g 10 pCi/g 154 (0%- 100%)

(0% - 100%)

(0% - 100%)

(0% - 100%)

(0%- 100%)

(0%- 100%)

(0%- 100%)

(0%- 100%)

(0%- 100%)

(0%-20%)

(0%- 20%)

(0%- 100%)

(0% - 100%)

(0% - 20%)

(0% - 100%)

(0% - 100%)

99

GENERAL ENGINEERING LABORATORIES, LLC 2040 Savage Road Charleston SC 29407 - (843) 556-8171 - www.gel.com QC Summary Workorder:

172275 Page 4 of 12 Parmnaame NOM Sample Qual QC Units RPD%

REC%

Range Anist Date Time Rad Gamma Spec Batch 574335 Thallium-208 TPU:

+/-0.0182 0.288 Uncert:

+/-0.0486 TPU:

+/-0.0486

+/-0.0215 0.314

+/-0.0534

+/-0.0534 pCi1g 9

(0% - 100%)

Actinium-228 Americiuro-24 1 LCS Bismuth-212 Bismuth-214 Cesium-134 Cesium-137 Cobalt-60 Europium-152 Europium-154 Europium-155 Uncert:

TPU:

23.4 Uncert:

TPU:

Uncert:

TPU:

Uncert:

TPU:

Uncert:

TPU:

9.56 Uncert:

TPU:

14.4 Uncert:

TPU:

Uncert:

TPU:

Uncert:

TPU:

Uncert:

TPU:

Uncert:

TPU:

Uncert:

TPU:

Uncert:

TPU:

Uncert:

TPU:

U

-0.336

+/-0.735

+/-0.735 24.1

+/-0.538

+/-0.538 U

-0.539

+/-1.04

+/-1.04 U

0.040

+/-0.261

+/-0.261 U

0.0448

+/-0.159

+/-0.159 10.6

+/-0.503

+/-0.503 15.0

+/-0.670

+/-0.670 U

0.0391

+/-0.272

+/-0.272

  • U

-0.103

+/-0.271

+/-0.271 U

-0.192

+/-0.281

+/-0.281 U

0.138

+/-0.155

+/-0.155 U

-0.0121

+/-0.202

+/-0.202 U

-0.0546

+/-0.141

+1-0.141 U

-0.0363

+/-0.124

+/-0.124 U

0.981 pCi/g pCi/g pCilg pCi/g pCi/g PCi/g pci/g pCi/g pCilg pCi/g pci/g pCi/g pci/g 110 (75%-125%)

104 (75%-125%)

103 (75%-125%)

10/03/06 16:53 Lead-212 Lead-214 Manganese-54 Niobium-94 Potassi um-40 100

GENERAL ENGINEERING LABORATORIES, LLC 2040 Savage Road Charleston SC 29407 - (843) 556-8171 - www.gel.com QC Summary Workorder:

172275 Page 5 of 12 Parmname NOM Sample Qual QC Units RPD%

REC%

Range AnIst Date Time Rad Gamma Spec Batch 574335 Radium-226 Silver-I O8m Thallium-208 QC1201196536 Actinium-228 Americium-241 MB Bismuth-212 Bismuth-214 Cesium-134 Cesium-137 Uncert:

TPU:

Uncert:

TPU:

Uncert:

TPU:

Uncert:

TPU:

Uncert:

TPU:

Uncert:

TPU:

Uncert:

TPU:

Uncert:

TPU:

Uncert:

TPU:

Uncert:

TPU:

Uncert:

TPU:

Uncert:

TPU:

Uncert:

TPU:

Uncert:

TPU:

Uncert:

TPU:

Uncert:

TPU:

+/-1.13

+/-1.13 U

0.040

+/-0.261

+/-0.261 U

-0.0285

+/-0.111

+/-0.111 U

-0.016

+/-0.114

+/-0.114 U

-0.00373

+/-0.0552

+/-0.0552 U

0.00356

+/-0.0133

+/-0.0133 U

0.0546

+/-0.117

+/-0.117 U

0.0344

+/-0.0333

+/-0.0333 U

0.00511

+1-0.0185

+/-0.0185 U

-0.0066

+/-0.0168

+/-0.0168 U

-0.000135

+/-0.0192

+/-0.0192 U

0.0299

+1-0.0364

+/-0.0364 U

-0.00197

+/-0.0618

+/-0.0618 U

-0.00897

+/-0.0242

+/-0.0242 U

0.0427

+/-0.0416

+/-0.0416 U

0.023

+/-0.0276

+/-0.0276 pci/g pCi/g pci/g pCi/g pci/g pCi/g pCi/g pCi/g pci/g pCi/g pCi/g pCi/g 10/03/06 13:39 (75%-125%)

Cobalt-60 Europium-152 Europium-154 Europium-155 Lead-212 Lead-214 101

GENERAL ENGINEERING LABORATORIES, LLC 2040 Savage Road Charleston SC 29407 - (843) 556-8171 - www.gel.com QC Summary Workorder:

172275 Page 6 of 12 Parmname NOM Sample Qual QC Units RPD%

REC%

Range Anlst Date Time Rad Gamma Spec Batch 574335 Manganese.54 Niobium-94 Potassium-40 Radium-226 Silver-108m Thallium-208 Uncert:

TPU:

Uncert:

TPU:

Uncert:

TPU:

Uncert:

TPU:

Uncert:

TPU:

Uncert:

TPU:

Batch 574336 QC 1201196540 Actinium-228 Americium-241 Bismuth-212 Bismuth-214 Cesium-134 Cesium-137 Cobalt-60 Europium-152 Europium-154 Europium-155 172275028 DUP 0.575 Uncert:

+/-0.137 TPU:

+/-0.137 U

-0.000377 Uncert

+/-0.0553 TPU:

+/-0.0553 0.487 Uncert:

+/-0.229 TPU:

+/-0.229 0.606 Uncert:

+/-0.0922 TPU:

+/-0.0922 U

0.027 Uncert:

+/-0.0188 TPU:

+/-0.0188 3.50 Uncert:

+/-0.317 TPU:

+/-0.317 0.089 Uncert:

+/-0.0294 TPU:

+/-0.0294 U

-0.0197 Uncert:

+/-0.049 TPU:

+/-0.049 U

-0.0211 Uncert:

+/-0.0462 TPU:

+/-0.0462 U

0.0382 U

0.00276

+/-0.0147

+/-0.0147 U

0.0082

+/-0.0143

+/-0.0143 U

0.223

+/-0.193

+/-0.193 U

0.0344

-+/-0.0333

+/-0.0333 U

-0.000323

+/-0.0132

+/-0.0132 U

0.00536

+/-0.0248

+/-0.0248 0.630

+/-0.144

+/-0.144 U

-0.000296

+/-0.0229

+/-0.0229 0.548

+/-0.181

+/-0.181 0.535

+/-0.0773

+/-0.0773 UI 0.00

+/-0.0445

+1-0.0445 U

0.0209

+/-0.0312

+/-0.0312 U

0.00347

+/-0.0186

+/-0.0186 U

-0.00689

+/-0.0417

+/-0.0417 U

0.081

+/-0.109

+/-0.109 U

0.0429 pCi/g pCi/g pCi/g pcilg pCi/g 9

(0% - 100%) MJHI 10/03/06 06:14 pCi/g 24 (0%- 100%)

pCi/g 12 pCi/g 12 pCi/g 72 pCi/g 198*

pCi/g 185 pCi/g 96 pCi/g 341 (0%- 100%)

(0%- 100%)

(0%- 100%)

(0%-20%)

(0%- 100%)

(0%- 100%)

(0%- 100%)

pCilg 12 (0%- 100%)

102

GENERAL ENGINEERING LABORATORIES, LLC 2040 Savage Road Charleston SC 29407 - (843) 556-8171 - www.gel.com QC Summary Workorder:

172275 Page 7 of 12 Parmname NOM Sample Qual QC Units RPD%

REC%

Range AnIst Date Time Rad Gamma Spec Batch 574336 Lead-212 Lead-214 Manganese-54 Niobium-94 Potassium-40 Radium-226 Silver-108m Thallium-208 QCI201196541 Actinium-228 Americium-241 Uncert:

+/-0.0686 TPU:

+/-0.0686 0.583 Uncert:

+/-0.066 TPU:

+/-0.066 0.695 Uncert:

+/-0.107 TPU:

+/-0.107 u

0.0169 Uncert:

+/-0.0161 TPU:

+/-0.0161 U

-0.00138 Uncert:

+/-0.0123 TPU:

+/-0.0123 9.02 Uncert:

+/-0.922 TPU:

+/-0.922 0.606 Uncert:

+/-0.0922 TPU:

+/-0.0922 U

-0.0159 Uncert:

+/-0.0205 TPU:

+/-0.0205 0.186 Uncert:

+/-0.0436 TPU:

+/-0.0436

+/-0.047

+/-0.047 0.738

+/-0.0492

+/-0.0492 0.589

+/-0.0747

+/-0.0747 U

0.0287

+/-0.0174

+/-0.0174 U

0.0073

+/-0.0179

+/-0.0179 12.2

+/-0.876

+/-0.876 0.535

+/-0.0773

+/-0.0773 U

0.0066

+/-0.014

+/-0.014 0.254

+/-0.0405

+1-0.0405 U

-0.000391

+/-0.575

+/-0.575 25.5

+/-2.52

+/-2.52 U

-0.528

+/-0.989

+/-0.989 U

0.0129

+/-0.236

+/-0.236 U

-0.0169

+/-0.145

+/-0.145 10.1

+/-0.768

+/-0.768 14.6

+/-1.01

+/-1.01 pCi/g 23*

(0%-20%)

pCi/g 17 (0% - 20%)

pCi/g 52 (0%- 100%)

pCi/g 293 (0%- 100%)

pCi/g 30*

pCi/g 12 (0%-20%)

(0%- 100%)

pCi/g 483 (0%-100%)

pCi/g 31 (0%- 100%)

LCS Bismuth-212 Bismuth-214 Cesium-134 Cesium-137 Uncert:

TPU:

23.4 Uncert:

TPU:

Uncert:

TPU:

Uncert:

TPU:

Uncert:

TPU:

9.56 Uncert:

TPU:

14.3 Uncert:

TPU:

PCi/g pCi/g pCi/g pCi/g pci/g 109 (75%-125%)

10/03/06 07:26 106 (75%-125%)

102 (75%-125%)

Cobalt-60 103

GENERAL ENGINEERING LABORATORIES, LLC 2040 Savage Road Charleston SC 29407 - (843) 556-8171 - www.gel.com Workorder:

172275 Parmname Rad Gamma Spec Batch 574336 Europium-152 Europium-154 Europium-155 Lead-212 Lead-214 Manganese-54 Niobium-94 Potassium-40 Radium-226 Silver-108m Thallium-208 QC1201196539 MB Actinium-228 Americium-241 Bismuth-212 Bismuth-214 Cesium-134 QC Summary Samnle Oual OC Page 8 of 12 Units RPPD%

REC%

Range Anrist Date Time NOM Uncert:

TPU:

Uncert:

TPU:

Uncert:

TPU:

Uncert:

TPU:

Uncert:

TPU:

Uncert:

TPU:

Uncert:

TPU:

Uncert:

TPU:

Uncert:

TPU:

Uncert:

TPU:

Uncert:

TPU:

Uncert:

TPU:

Uncert:

TPU:

Uncert:

TPU:

Uncert:

TPU:

Uncert:

-0.0086.1

+/-0.365

+/-0.305 0.382

+/-0.275

+/-0.275

-0.0392

+/-0.332

+/-0.332

-0.11

+/-0.163

+1-0.163 0.185

+/-0.234

+/-0.234

-0.00693

+/-0.128

+/-0.128

-0.0972

+/-0.118

+/-0.118 0.676

+/- 1.06

+/-1.06 0.0129

+/-0.236

+/-0.236

-0.0142

+/-0.119

+/-0.119 0.100

+/-0.123

+/-0.123 0.0435

+/-0.091

+/-0.091

-0.0204

+/-0.055

+/-0.055

-0.00499

+/-0.109

+/-0.109 0.0577

+/-0.031

+/-0.031 0.00937

+/-0.0158 pCi/g Pci/g pCi/g Pcilg pCilg Pci/g pCi/g Pci/g Pci/g Pci/g pCi/g Pci/g Pci/g Pci/g (75%- 125%)

U U

U U

U 10/03/06 06:13 104

GENERAL ENGINEERING LABORATORIES, LLC 2040 Savage Road Charleston SC 29407 - (843) 556-8171 - www.gel.com QC Summary Workorder:

172275 Page 9of 12 Parmname NOM Sample Qual QC Units RPD%

REC%

Range Anist Date Time Rad Gamma Spec Batch 574336 TPU:

+/-0.0158 Cesium-137 U

-0.00291 pCi/g Uncert:

+/-0.0137 TPU:

+/-0.0137 Cobalt-60 U

0.000491 pCi/g Uncert:

+/-0.0155 TPU:

+/-0.0155 Europium-152 U

-0.00472 pCi/g Uncert:

+/-0.0376 TPU:

+/-0.0376 Europium-154 U

0.00671 pCi/g Uncert:

+/-0.0299 TPU:

+/-0.0299 Europium-155 U

0.0139 pCi/g Uncert:

+/-0.0336 TPU:

+/-0.0336 Lead-212 U

0.0167 pCilg Uncert:

+/-0.0287 TPU:

+/-0.0287 Lead-214 U

0.0536 pCilg Uncert:

+/-0.0433 TPU:

+/-0.0433 Manganese-54 U

-0.00217 pCilg Uncert:

+1-0.0116 TPU:

+/-0.0116.

Niobium-94 U

0.0106 pCi/g Uncert:

+/-0.0136 TPU:

+/-0.0136 Potassium-40 U

0.0767 pCi/g Uncert:

+/-0.436 TPU:

+/-0.436 Radium-226 U

0.0577 pCi/g Uncert:

+/-0.031 TPU:

+/-0.031 Silver-108m U

0.0117 pCi/g Uncert:

+/-0.0122 TPU:

+/-0.0122 Thallium-208 U

0.0111 pCi/g Uncert:

+/-0.0142 TPU:

+/-0.0142 Rad Gas Flow Batch 572301 QC1201191724 172275003 DUP Strontium-90 u

-0.00839 U

0.00318 pCi/g 0

(0% - 100%) KSDI 09/28/06 07:35 Uncert:

+/-0.0152

+/-0.0168 TPU:

+/-0.0152

+/-0.0168 QC1201191726 LCS Strontium-90 1.56 1.44 pCi/g 92 (75%-125%)

09/28/06 07:35 105

GENERAL ENGINEERING LABORATORIES, LLC 2040 Savage Road Charleston SC 29407 - (843) 556-8171 - www.gel.com Workorder:

172275 Parmname Rad Gas Flow Batch 572301 QC1201191723 MB Strontium-90 QC1201191725 172275003 MS Strontium-90 Rad Liquid Scintillation Batch 571874 QC1201190758 172275008 DUP Iron-55 QC1201190760 LCS Iron-55 QC1201190757 MB Iron-55 QC1201190759-172275008 MS Iron-55 Batch 571876 QC1201190768 172275014 DUP Nickel-63 QC12011 90770 LCS Nickel-63 QCI201196767 MB Nickel-63 QC1201190769 172275014 MS Nickel-63 Batch 571877 QC1201190772 172275003 DUP Technetium-99 NOM Uncert:

TPU:

Uncert:

TPU:

2.99 Uncert:

TPU:

Uncert:

TPU 693 Uncert:

TPU:

Uncert:

TPU:

712 Uncert:

TPU Uncert:

TPU 573 Uncert:

.TPU:

Uncert:

TPU:

575 Uncert:

TPU:

U QC Summary Sample Qual QC

+/-0.103

+/-0.113 U

-0.00844

+/-0.0137

+/-0.0137

-0.00839 2.97

+/-0.0152

+/-0.209

+/-0.0152

+/-0.220 Page 10of 12 Units RPD%

REC%

Range AnIst Date Time U

U 0.774 U

+/-38.8

+/-38.8 U

U 0.774

+1-38.8

+/-38.8 U

-3.05 U

+/-9.26

+/-9.26 U

U

-3.05

+/-9.26

+/-9.26 U

0.165 U

-16.1

+/-34.9

+/-34.9 549

+/-53.2

+/-65.2 0.248

+/-31.9

+/-31.9 595

+/-55.5

+/-68.7

-6.06

+/-6.04

+/-6.04 461

+/-14.5

+/-21.3

-1.34

+/-6.42

+/-6.42 546

+1-16.4

+/-24.7

-0.0959 pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCilg 99 (75%-125%)

0 (0% - 100%) VIXPI 79 (75%-125%)

84 (75%-125%)

0 (0%- 100%) VIXPI 80 (75%-125%)

95 (75%-125%)

09/28/06 07:34 09/28/06 07:35 09/28/06 18:42 09/28/06 19:14 09/28/06 18:26 09/28/06 18:58 09/29/06 21:48 09/29/06 23:21 09/29/06 21:01 09/29/06 22:34 10/02/06 13:02 pCi/g 0

(0% -100%) KXR1 106

GENERAL ENGINEERING LABORATORIES, LLC 2040 Savage Road Charleston SC 29407 - (843) 556-8171 - www.gel.com QC Summary Workorder:

172275 Page 11 of 12 Parmname NOM Sample Qual

.QC Units RPD%

REC%

Range Anist Date Time Rad Liquid Scintillation Batch 571877 QC1201190774 LCS Technetium-99 QC1201190771 MB Technetium-99 Uncert:

+/-0.222 TPU:

+/-0.222

+/-0.189

+/-0.189 12.6

+/-0.360

+/-0.480 13.1 Uncert:

TPU:

Uncert:

TPU:

12.4 U

Uncert:

TPU:

U

-0.0467

+/-0.168

+/-0.168 pCi/g pCi/g pCilg 96 (75%-125%)

10/02/06 14:05 10/02/06 12:30 10/02/06 13:33 QC1201190773 Technetium-99 172275003 MS 0.165

+/-0.222

+/-0.222 Batch 571880 QC1201190784 172275003 DUP Carbon-14 QC1201190786 LCS Carbon-14 QC1201190783 MB Carbon-14 QC1201190785 172275003 MS Carbon-14 U

-0.0626 Uncert:

+/-0.105 TPU:

+/-0.105 U

11.6

+/-0.372

+/-0.474

-0.15

+/-0.103

-/-0.103 6.36

+/-0.181

+1-0.206 94 (75%-125%)

pCilg 0

(0% - 100%) kXD2 09/26/06 00:01 6.47 Uncert:

TPU:

Uncert:

TPU:

6.82 U

Uncert:

TPU:

U

-0.0559

+/-0.0984

+/-0.0984 pCilg pCilg pCilg 98 (75%-125%)

09/26/06 02:26 09/25/06 22:48 09/26/06 01:13

-0.0626

+/-0.105

+/-0.105 Batch 571884 QC1201190794 172275003 DUP Tritium QC1201190796 LCS Tritium QC1201190793 MB Tritium QC1201190795 172275003 MS Tritium 32.4 Uncert:

+/-8.92 TPU:

+/-8.93 6.60

+/-0.190

+/-0.216 43.4

+/-9.76

+1-9.79 47.9

+/-8.75

+/-8.79 97 (75%-125%)

pCi/g 29 (0% - 100%) DFA I 52.4 Uncert:

TPU:

Uncert:

TPU:

52.5 Uncert:

TPU:

U

-1.35

+/-5.87

+/-5.87 pCi/g pCi/g pci/g 91 (75%-125%)

09/27/06 19:30 09/27/06 20:03 09/27/06 19:14 09/27/06 19:47 32.4

+/-8.92

+/-8.93 88.6

+/-10.7

+/-10.8 107 (75%-125%)

107

GENERAL ENGINEERING LABORATORIES, LLC 2040 Savage Road Charleston SC 29407 - (843) 556-8171 - www.gel.com QC Summary Workorder:

172275 Page 12 of 12 Parnmame NOM Sample Qua]

QC Units RPD%

REC%

Range Anist Date Timi Notes:

The Qualifiers in this report are defined as follows:

A quality control analyte recovery is outside of specified acceptance criteria Result is less than value reported Result is greater than value reported A

The TIC is a suspected aldol-condensation product B

Target analyte was detected in the associated blank BD Results are either below the MDC or tracer recovery is low C

Analyte has been confirmed by GC/MS analysis D

Results are reported from a diluted aliquot of the sample H

Analytical holding time was exceeded J

Value is estimated N/A Spike recovery limits do not apply. Sample concentration exceeds spike concentration by 4X or more R

Sample results are rejected U

Analyte was analyzed for, but not detected above the MDL, MDA, or LOD.

UI Gamma Spectroscopy--Uncertain identification X

Consult Case Narrative, Data Summary package, or Project Manager concerning this qualifier Y

QC Samples were not spiked with this compound A

RPD of sample and duplicate evaluated using +/-RL. Concentrations are <5X the RL h

Preparation or preservation holding time was exceeded N/A indicates that spike recovery limits do not apply when sample concentration exceeds spike conc. by a factor of 4 or more.

    • Indicates analyte is a surrogate compound.

^ The Relative Percent Difference (RPD) obtained from the sample duplicate (DUP) is evaluated against the acceptence criteria when the sample is greater than five times (5X) the contract required detection limit (RL). In cases where either the sample or duplicate value is less than 5X the RL, a control limit of +/- the RL is used to evaluate the DUP result.

For PS, PSD, and SDILT results, the values listed are the measured amounts, not final concentrations.

Where the analytical method has been performed under NELAP certification, the analysis has met all of the requirements of the NELAC standard unless qualified on the QC Summary.

e 108

General Narrative 1

General Narrative for Connecticut Yankee Atomic Power Co.

Work Order: 173769 SDG: MSR#06-1282 October 16, 2006 Laboratory Identification:

General Engineering Laboratories, LLC 2040 Savage Road Charleston, South Carolina 29407 (843) 556-8171 Summary Sample receipt The samples arrived at General Engineering Laboratories, LLC, Charleston, South Carolina on September 21, 2006 for analysis. Shipping container temperatures were checked, documented, and within specifications. The samples were delivered with proper chain of custody documentation and signatures. All sample containers arrived without any visible signs of tampering or breakage.

Sample Identification The laboratory received the following samples:

Laboratory Identification 173769001 173769002 173769003 173769004 173769005 173769006 173769007 Sample Description 9807-0000-002F 9807-0000-003F 9807-0000-006F 9807-0000-007F 9807-0000-008F 9807-0000-013F 9807-0000-014F Items of Note Jack McCarthy requested H3 analysis of the samples listed above via email on 10/10/06.

Case Narrative Sample analyses were conducted using methodology as outlined in General Engineering Laboratories (GEL) Standard Operating Procedures. Any technical or administrative problems during analysis, data review, and reduction are contained in the analytical case narratives in the enclosed data package.

Analytical Request Seven soil samples were analyzed for Tritium.

2

Data Package The enclosed data package contains the following sections: General Narrative, Chain of Custody and Supporting Documentation, Data Review Qualifier Definitions, and data from the following fractions:

Radiochemistry.

I certify that this data package is in compliance with the SOW, both technically and for completeness, for other than the conditions detailed above. Release of the data contained in this hard copy data package has been authorized by the Laboratory Manager or a designee, as verified by the following signature.

Cheryl Jones Project Manager 3

List of current GEL Certifications as of 16 October 2006 State Certification Alaska UST-062 Arizona AZ0668 Arkansas 88-0651 CLIA 42D0904046 California 01151CA Colorado GenEngLabs Connecticut PH-0169 Dept. of Navy NFESC 413 EPA WG-15J Florida/NELAP E87156 Georgia E87156 (FLINELAP)

Hawaii N/A Idaho N/A Illinois 200029 Indiana C-SC-01 Kansas E-10332 Kentucky 90129 Louisiana 03046 Maryland 270 Massachusetts M-SC012 Michigan 9903 Nevada SC12 New Jersey SCO02 New Mexico FL NELAP E87156 New York 11501 North Carolina 233 North Carolina Drinking W 45709 North Dakota R-158 Oklahoma 9904 Pennsylvania 68-00485 South Carolina 10120001/10585001/10120002 Tennessee 02934 Texas TX213-2006A Texas NELAP T104704235-06-TX U.S. Dept. of Agriculture S-52597 US Army Corps of Engineer N/A Utah 8037697376 GEL Vermont VT87156 Virginia 00151 Washington C 1641 4

Chain of Custody and Supporting Documentation 5

Health Physics Procedure GPP.GGGR-R5104-003-Attachment B-CY-00 I Major Oh Connecticut Yankee Atomic Power Company Chain of Custody Form 2

362 lnjun Hollow Road, East Hampton, CT 06424 860-267-2556 Project Name: Haddam Neck Decommissioning Analyses Requested Lab Use Only Contact Name & Phone:

Comments:

Jack McCarthy 960-267-3924 Medie Sample Container Code Type Size-Analytical Lab (Name, City, State):

Code

&Type General Engineering Laboratories Code 2040 Savage Road Charleston, SC 29407 ATT: CherylJones (843-556-8171)

Priority: " 30 D. E 14 D. 1[ 7 D.

Other:

rn Sample Desi ation Date Time Comment, Preservation Lab Sample ID 9807-0000-0I F 9146161 q M TS C

P BP 9807-0000-0eO;I.

JA,_

TS C

BP 9807-0000-003r.7 TS C

BP 9807-0000-00 414106 YS3 TS C

BP

_z 9807-0000-0 Q

D&

JOST7 TS C

BP 9807-0000-0 oJp F 106-TS C

BP 9807-0000-0Otq A

  • .t TS C

BP 9807"0000"0c3% F 1W.

5-.

TS C

BP 9807-0000-0 o Tf:

CTS IC BP 9807-0000-0.oo

o.
  • j1 A T" TS C

-BP t

9807-0000-0 t ý. IFlj 10 2

-1.

TS C

BP NOTES: PO #: 002332 MSR #:

=-/0

7.t Z

LTP QA 0

Radwaste QA E Non QA Samples Shipped Via:

Internal Container

[

Fed Ex Temp.: /

Deg. C Tups EHand Custody Seals?

1) Relinquihed Date/Time 2Nceiv By^.

DteiTime Custody Seal Intact?

3) Relinquished by Date/Fime 4 Receive~d BP Date/Time Billof Y Y]

N E Bi5 of LadRiug B

5) Relinquished By Date/Time
6) Received By Date/Time

Healtý Physics Procedure GPP-GGGR-R5104-003-Attachment B-CY-00 1 Major Connecticut Yankee Atomic Power Company Chain of Custody Form No. 2006-569 362 Injun Hollow Road, East Hampton, CT 06424 860-267-2556 Project Name: Haddam Neck Decommissioning Analyses Requested Lab Use Only Contact Name & Phone:

Comments:

Jack McCarthy 860-267-3924 Media Sample Container Code Type Size-Analytical Lab (Name, City, State):

Codae

&Type General Engineering Laboratories Code 2040 Savage Road Charleston, SC 29407 ATM: Cheryl Jones (843-556-8171)

Priority: [130 D. Z 14 D. [17 D.

Other:

ri c

Sample Designation Date Time r

F Comment, Preservation Lab Sample ID 9807-0000-0 *, F=.

,:e G*(,

o

_____TS CBP___...___

9807-0000-0 L~

q-1L4-(.p G*d**

TS C

BP

~,

@'oDn_______

9807-0000-0 {

  • .iL4.oto TS C

BP o

9807-0000-0 OLFs l'toL TS C

BP goo 9807-0000-0 j

  • .f'.o TS C

BP 9807-0000-0 14 IC 110- IOU ockibe' TS C

BP

)0 9807-0000-0 1 **j 4

-cA D v-TS C

BP 98700- %JF6-c4 TS C

HP 9807-0000-0 TS C

BP 9807-0000-0 T**

-*r*

t

'S, C

BP 9807-0000-0 xGW TS C

BP 9807-0000-0-cre' v

9 tebeQ TS C

HP NOTES: PO #: 002332 MSR #: 04-1t g-"

LTP QA U Radwaste QA U Non QA Samples Shipped Via:

Internal Container

[

Fed Ex Temp.: _

Deg. C El uPS El Hand Custody Sealep YE NZ

1) Relinquished By Date/Tne
2) ee at/Time OtherCustody SetC Intact?

_)_R

__in______dByD__e/T 2

e z)/O~

9c Eq l [

Other

3) Relinquished By Date/Time
4) ý,eceived 5y Date/Time Y CY N 0 Bill of Lading 9
5) Relinquished By Date/Time
6) Received By Date/Time

Heallb Physics Procedure GPP-GGGR-R.5104-003-Attachment B-CY-001 Major Chain of Custody Form N.20-7 Connecticut Yankee Atomic Power Company No. 2o06-57o 362 Injun Hollow Road, East Hampton, CT 06424 860-267-2556 Project Name: Haddam Neck Decommissioning Analyses Requested Lab Use Only Contact Name & Phone:

Comments:

Jack McCarthy 860-267-3924 Media Sample Container Code Type Size-Analytical Lab (Name, City, State):

Code

&Type General Engineering Laboratories Code 2040 Savage Road Charleston, SC 29407 ATT: Cheryl Jones (843-556-8171)

Priority: El 330 D. Z 14 D.E 7 D.

Other; W__CO)_

Sample Designation Date Time Comment, Preservation.

Lab Sample ID 9807-0000-0?.' 1

q. rd -0 TS C

BP 9807.000.-.mVFt w q4.o.

I,.. Z7 TS CD RP.

7, --,-.

-.- e --- - -

9807-0000-0 7,;

4LlýL D.

TS C

BP 9807-0000-0" 7*F TS C

BP 9807-0000-0

-,.3q*

li,-50 TS C

BP 106JLP1 5E

-TS C1 KP_

NOTES: PO 4: 002332 MSR #: a£6 Ii'".

I LTP QA E

Radwaste QA

[

Non QA Samples Shipped Via:

Internal Container ED Fed Ex Temp.:

' Deg. C El Hand Custody Sealed

1) Relinquished By Date/Time
2) 1ve y

)atefime Custody SeaY ntact?

(?6 Other

3) Relinquished By Date/Time
4) Received DaterTime YD]

N Bill of Lading #

5) Relinquished By Date/Time
6) Received By Date/Time

Connecticut Yankee Statement of Work for Analytical Lab Services CY-ISC-SOW-OO1 Figure 1. Sample Check-in List.

Date/Tim*

Received:-.....

,Q.

SDG#:

'Work Order Number.

Shipping Cdatainer 7

Chain of Custody #

-9 j6to-JLGf7C

1.

Custody Seats.o 0shipping container intact?",

Yes 1 ] No AI 414-

2.

Custody Seals dated and signed?

Yes,[

No [ 1 44

.3.

Chain-of-Custody recor d pret Ye

)I

4.

Coolert Imperatur

5.

Vermiculite/packing materials is:

Wet ( I Dry j',' I /vP

6.

Number of samples in shipping conmtainr:

7.

Sample holding times exceeded?

f Y* I]NO

8. Samples havei l*ap Jiazard labels

__.custody seals

-Z2approp-iate sample labels

9. Samples arei

.~J.god condition

-leaking

-broken have air bubbles

10.

Were any anomalie.s identified in sarmple receipt?

Yes [ ] No,?

i 1.

escripon of anomalies, (ilude staple numbers):

Sample Custodian(Laboratory

.<L 4

Date, Telepho.: ed to, On

,By 9

Prep for additional analysis (and reanalysis)

Subject:

Prep for additional analysis (and reanalysis)

From: "John McCarthy" <McCarthy@CYAPCO.com>

Date: Tue, 10 Oct 2006 13:47:15 -0400 To: "Cheryl Jones" <cj@gel.com>

CC: "Clyde Newson" <Newson@CYAPCO.com>

Cheryl, Would prep and analyses the following samples under MSR 0601282 for H-3:

9807-0000-002F 9807-0000-003F (REANALYSIS) 9807-0000-006F 9807-0000-007F 9807-0000-008F (REANALYSIS) 9807-0000-013F (REANALYSIS).

9807-0000-014F TAT IS REQUESTED AT 7 DAYS. RDL IS REQUESTED AT 3 PCI/G (3.OOE+00 PCI/G)

Thank you

.Jack 10 I of I 10/ 17/2006 2:5 0 PM

Data Review Qualifier Definitions 11

Data Review Qualifier Definitions Qualifier Explanation A quality control analyte recovery is outside of specified acceptance criteria Analyte is a surrogate compound c

Result is less than value reported Result is greater than value reported

..RPD of sample and duplicate evaluated using +/-RL. Concentrations are <5X the RL A

The TIC is a suspected aldol-condensation product B

Target analyte was detected in the associated blank B

Metals-Either presence of analyte detected in the associated blank, or MDL/IDL < sample value < PQL BD Results are either below the MDC or tracer recovery is low C.

Analyte has been confirmed by GC/MS analysis D

Results are reported from a diluted aliquot of the sample d

5-day BOD-The 2:1 depletion requirement was not met for this sample E

Organics-Concentration of the target analyte exceeds the instrument calibration range Metals-%difference of sample and SD is

>10%.

Sample concentration must meet flagging criteria B

Analytical holding time was exceeded h

Preparation or preservation holding time was exceeded J

Value is estimated N

Metals-The Matrix spike sample recovery is not within specified control limits N

Organics-Presumptive evidence based on mass spectral library search to make a tentative identification of the analyte. (TIC). Quantitation is based on nearest internal standard response factor N/A Spike recovery limits do not apply.

Sample concentration exceeds spike concentration by 4X or more ND Analyte concentration is not detected above the reporting limit UI Gamma Spectroscopy-Uncertain identification X

Consult Case Narrative, Data Summary package, or Project Manager concerning this qualifier Y

QC Samples were not spiked with this compound Z

Paint Filter Test-Particulates passed through the filter, however no free liquids were observed.

GENERAL ENGINEERING LABOPATORIES, LLC a Member of THE GEL GROUP, INC.

P.O. BOX 30712 Charleston, SC 29417 - 2040 Savage Road (29407)

Phone (B43) 556-8171 -FeI23) 766-1178 www.gel.com

RADIOLOGICAL ANALYSIS 13

Radiochemistry Case Narrative Connecticut Yankee Atomic Power Co. (YANK)

Work Order 173769 Method/Analysis Information Product:

LSC, Tritium Dist, Solid - 3 pCi/g Aiialytical Method:

Analytical Batch Number:

Sample ID 173769001 173769002 173769003 173769004 173769005 173769006 173769007 1201205181 1201205182 1201205183 1201205184 EPA 906.0 Modified 578364 Client ID 9807-0000-002F 9807-0000-003F 9807-0000-006F 9807-0000-007F 9807-0000-008F 9807-0000-013F 9807-0000-014F Method Blank (MB) 173770001(9106-0001-1 12F) Sample Duplicate (DUP) 173770001(9106-0001-112F) Matrix Spike (MS)

Laboratory Control Sample (LCS)

SOP Reference Procedure for preparation, analysis and reporting of analytical data are controlled by General Engineering Laboratories, LLC as Standard Operating Procedure (SOP). The data discussed in this narrative has been analyzed in accordance with GL-RAD-A-002 REV# 13.

Calibration Information:

Calibration Information All initial and continuing calibration requirements have been met.

Standards Information Standard solution(s) for these analyses are NIST traceable and used before the expiration date(s).

Sample Geometry All counting sources were prepared in the same geometry as the calibration standards.

14

Quality Control (OC) Information:

Blank Information The blank volume is representative of the sample volume in this batch.

Designated QC The following sample was used for QC: 173770001 (9106-0001-112F).

QC Information All of the QC samples met the required acceptance limits.

Technical Information:

Holding Time All sample procedures for this sample set were performed within the required holding time.

Preparation Information All preparation criteria have been met for these analyses.

Sample Re-prep/Re-analysis None of the samples in this sample set required reprep or reanalysis.

Miscellaneous Information:

NCR Documentation Nonconformance reports are generated to document any procedural anomalies that may deviate from referenced SOP or contractual documents. A nonconformance report (NCR) was not generated for this SDG.

Additional Comments The container ids were verified for samples 173769002 (9807-0000-003F) and 173769005 (9807-0000-008F).

Qualifier information Manual qualifiers were not required.

Certification Statement Where the analytical method has been performed under NELAP certification, the analysis has met all of the requirements of the NELAC standard unless otherwise noted in the analytical case narrative.

Review Validation:

GEL requires all analytical data to be verified by a qualified data validator. In addition, all data designated for CLP or CLP-like packaging will receive a third level validation upon completion of the data package.

The following data validator verified the information presented in this case narrative:

15

Reviewer/Date:

16

SAMPLE DATA

SUMMARY

17

GENERAL ENGINEERING LABORATORIES, LLC 2040 Savage Road Charleston SC 29407 - (843) 556-8171 - www.gel.com Certificate of Analysis Report for YANK001 Connecticut Yankee Atomic Power Co.

Client SDG: MSR#06-1282 GEL Work Order: 173769 The Qualifiers in this report are defined as follows:

A quality control analyte recovery is outside of specified acceptance criteria Analyte is a surrogate compound U

Analyte was analyzed for, but not detected above the MDL, MDA, or LOD.

ND The analyte concentration is not detected above the detection limit.

The above sample is reported on an "as received" basis.

Where the analytical method has been performed under NELAP certification, the analysis has met all of the requirements of the NELAC standard unless qualified on the Certificate of Analysis.

This data report has been prepared and reviewed in accordance with General Engineering Laboratories, LLC standard operating procedures. Please direct any questions to your Project Manager, Cheryl Jones.

Reviewed by 18

GENERAL ENGINEERING LABORATORIES, LLC 2040 Savage Road Charleston SC 29407 - (843) 556-8171 - www.gel.com Certificate of Analysis Company:

Connecticut Yankee Atomic Power Address :

362 Injun Hollow Rd

Contact:

Project:

East Hampton, Connecticut 06424 Mr. Jack McCarthy Soils PO# 002332 Report Date: October 18, 2006 Client Sample ID:

9807-0000-002F Proiect:

YANK01204 Sample ID:

173769001 ClientID:

YANK001 Matrix:

TS Vol. Recv.:

Collect Date:

13-SEP-06 Receive Date:

21-SEP-06 Collector:

Client Parameter Qualifier

  • Result Uncertainty LC TPU MDA Units DF Analyst Date Time Batch Mtd Rad Liquid Scintillation Analysis LSC, Tritium Dist. Solid - 3 pCi/g Tritium U

0.231

+/-1.43 1.19

+/-1.43 2.55 pCi/g DFAI 10/14/062310 578364 1

The following Analytical Methods were performed Method Description I

EPA 906.0 Modified Notes:

The Qualifiers in this report are defined as follows A quality control analyte recovery is outside of specified acceptance criteria Result is less than value reported Result is greater than value reported A

The TIC is a suspected aldol-condensation product B

Target analyte was detected in the associated blank BD Results are either below the MDC or tracer recovery is low C

Analyte has been confirmed by GC/MS analysis D

Results are reported from a diluted aliquot of the sample H

Analytical holding time was exceeded J

Value is estimated N/A Spike recovery limits do not apply. Sample concentration exceeds spike concentration by 4X or more R

Sample results are rejected U

Analyte was analyzed for, but not detected above the MDL, MDA, or LOD.

UI Gamma Spectroscopy-Uncertain identification X

Consult Case Narrative, Data Summary package, or Project Manager concerning this qualifier Y

QC Samples were not spiked with this compound A

RPD of sample and duplicate evaluated using +l-Rb. Concentrations are <5X the RL h

Preparation or preservation holding time was exceeded The above sample is reported on an "as received" basis.

19

GENERAL ENGINEERING LABORATORIES, LLC 2040 Savage Road Charleston SC 29407 - (843) 556-8171 - www.gel.com Certificate of Analysis Company:

Connecticut Yankee Atomic Power Address:

362 Injun Hollow Rd.

East Hampton, Connecticut 06424 Report Date: October 18, 2006

Contact:

Mr. Jack McCarthy Project:

Soils PO# 002332 Client Sample ID:

9807-0000-003F Project:

YANK0 1204 Sample ID:

173769002 Client ID:

YANK001 Matrix:

TS Vol. Recv.:

Collect Date:

13-SEP-06 Receive Date:

21-SEP-06 Collector:

Client Parameter Qualifier Result Uncertainty LC TPU MDA Units DF Analyst Date Time Batch Mtd Rad Liquid Scintillation Analysis LSC, Tritium Dist, Solid -

3 pCi/g Tritium U

0.154

+1-1.28 1.07

+/-1.28 2.29 pCi/g DFAJ 10/14/062326 578364 1

The following Analytical Methods were perfonned Method Description I

EPA 906.0 Modified Notes:

The Qualifiers in this report are defined as follows:

A quality control analyte recovery is outside of specified acceptance criteria Result is less than value reported Result is greater than value reported A

The TIC is a suspected aldol-condensation product 13 Target analyte was detected in the associated blank BD Results are either below the MDC or tracer recovery is low C

Analyte has been confirmed by GC/MS analysis D

Results are reported from a diluted aliquot of the sample H

Analytical holding time was exceeded J

Value is estimated N/A Spike recovery limits do not apply. Sample concentration exceeds spike concentration by 4X or more R

Sample results are rejected U

Analyte was analyzed for, but not detected above the MDL, MDA, or LOD.

UI Gamma Spectroscopy--Uncertain identification X

Consult Case Narrative, Data Summary package, or Project Manager concerning this qualifier Y

QC Samples were not spiked with this compound A

RPD of sample and duplicate evaluated using +/-RL. Concentrations are <5X the RL h

Preparation or preservation holding time was exceeded The above sample is reported on an "as received" basis.

20

GENERAL ENGINEERING LABORATORIES, LLC 2040 Savage Road Charleston SC 29407 - (843) 556-8171 - www.gel.com Certificate of Analysis Company : Connecticut Yankee Atomic Power Address*:

362 Injun Hollow Rd.........

East Hampton, Connecticut 06424

Contact:

Mr. Jack McCarthy Project:

Soils PO# 002332 Report Date: October 18, 2006 Client Sample ID:

Sample ID:

Matrix:

Collect Date:

Receive Date:

Collector:

9807-0000-006F 173769003 TS 14-SEP-06 21-SEP-06 Client Project:

YANK01204 Client ID:

YANK00I Vol. Recv.:

Parameter Qualifier Result Uncertainty LC TPU MDA Units DF Analyst Date Time Batch Mtd Rad Liquid Scintillation Analysis ISC, Tritium Dist, Solid -

3 pCi/g Tritium U

0.0691

+/-1.64 1.37

+/-1.64 2.94 pCi/g DFAl 10/14/06 2343 578364 1

The following Analytical Methods wereperformed Method Description I

EPA 906.0 Modified Notes:

The Qualifiers in this report are defined as follows:

A quality control analyte recovery is outside of specified acceptance criteria Result is less than value reported Result is greater than value reported A

The TIC is a suspected aldol-condensation product B

Target analyte was detected in the associated blank BD Results are either below the MDC or tracer recovery is low C

Analyte has been confirmed by GCUMS analysis D

Results are reported from a diluted aliquot of the sample H

Analytical holding time was exceeded J

Value is estimated N/A Spike recovery limits do not apply. Sample concentration exceeds spike concentration by 4X or more R

Sample results are rejected U

Analyte was analyzed for, but not detected above the MIL, MDA, or LOD.

UI Gamma Spectroscopy--Uncertain identification X

Consult Case Narrative, Data Summary package, or Project Manager concerning this qualifier Y

QC Samples were not spiked with this compound A

RPD of sample and duplicate evaluated using +/-RL. Concentrations are <5X the RL h

Preparation or preservation holding time was exceeded The above sample is reported on an "as received" basis.

21

GENERAL ENGINEERING LABORATORIES, LLC 2040 Savage Road Charleston SC 29407 - (843) 556-8171 - www.gel.com Certificate of Analysis Company:

Connecticut Yankee Atomic Power

" " Address :

362 In jun Hollow Rd.........

East Hampton, Connecticut 06424 Report Date: October 18, 2006

Contact:

Mr. Jack McCarthy Project:.

Soils PO# 002332 Client Sample ID:

9807-0000-007F Project:

YANK01204 Sample ID:

173769004 Client ID:

YANK001 Matrix:

TS Vol. Recv.:

Collect Date:

14-SEP-06 Receive Date:

21 -SEP-06 Collector:

Client Parameter Qualifier Result Uncertainty LC TPU MDA Units DF Analyst Date Time Batch Mtd Rad Liquid Scintillation Analysis LSC, Tritium Dist, Solid -

3 pCi/g Tritium U

0.00

+/-1.24 1.04

+/-1.24 2.23 pCi/g DFAI 10/14/06 2359 578364 1

The following Analytical Methods were performed Method Description EPA 906.0 Modified Notes:

The Qualifiers in this report are defined as follows:

A quality control analyte recovery is outside of specified acceptance criteria Result is less than value reported Result is greater than value reported A

The TIC is a suspected aldol-condensation product B

Target analyte was detected in the associated blank BD Results are either below the MDC or tracer recovery is low C

Analyte has been confirmed by GC/MS analysis D

Results are reported from a diluted aliquot of the sample H

Analytical holding time was exceeded J

Value is estimated N/A Spike recovery limits do not apply. Sample concentration exceeds spike concentration by 4X or more R

Sample results are rejected U

Analyte was analyzed for, but not detected above the MDL, MDA, or LOD.

UI Gamma Spectroscopy-Uncertain identification X

Consult Case Narrative, Data Summary package, or Project Manager concerning this qualifier Y

QC Samples were not spiked with this compound A

RPD of sample and duplicate evaluated using +/-RL. Concentrations are <5X the RL h

Preparation or preservation holding time was exceeded The above sample is reported on an "as received" basis.

22

GENERAL ENGINEERING LABORATORIES, LLC 2040 Savage Road Charleston SC 29407 - (843) 556-8171 - www.gel.com Certificate of Analysis Company Connecticut Yankee Atomic Power Address:

362 Injun Hollow Rd East Hampton, Connecticut 06424 Report Date: October 18, 2006

Contact:

Mr. Jack McCarthy Project:

Soils PO# 002332 Client Sample ID:

9807-0000-008F Proeect:

YANKO1204 Sample ID:

173769005 Client ID:

YANK001 Matrix:

TS Vol. Recv.:

Collect Date:

14-SEP-06 Receive Date:

21-SEP-06 Collector:

Client Parameter Qualifier Result Uncertainty LC TPU MDA Units DF Analyst Date Time Batch Mtd Rad Liquid Scintillation Analysis LSC, Tritium Dist, Solid -

3 pCifg Tritium U

0.575

+/-1.33 1.08

+/-1.33 2.31 pCilg DFAI 10/15/06 0015 578364 1

The following Analytical Methods were performed Method Description EPA 906.0 Modified Notes:

The Qualifiers in this report are defined as follows:

A quality control analyte recovery is outside of specified acceptance criteria Result is less than value reported Result is greater than value reported A

The TIC is a suspected aldol-condensation product B

Target analyte was detected in the associated blank BD Results are either below the MDC or tracer recovery is low C

Analyte has been confirmed by GC/MS analysis D

Results are reported from a diluted aliquot of the sample H

Analytical holding time was exceeded J

Value is estimated N/A Spike recovery limits do not apply. Sample concentration exceeds spike concentration by 4X or more R

Sample results are rejected U

Analyte was analyzed for, but not detected above the MDL, MDA, or LOD.

UI Gamma Spectroscopy--Uncertain identification X

Consult Case Narrative, Data Summary package, or Project Manager concerning this qualifier Y

QC Samples were not spiked with this compound A

RPD of sample and duplicate evaluated using +/-RL. Concentrations are <5X the RL h

Preparation or preservation holding time was exceeded The above sample is reported on an "as received" basis.

23

GENERAL ENGINEERING LABORATORIES, LLC 2040 Savage Road Charleston SC 29407 - (843) 556-8171 - www.gel.com Certificate of Analysis Company: Connecticut Yankee Atomic Power Address :

362 Injun Hollow Rd East Hampton, Connecticut 06424 Report Date: October 18, 2006

Contact:

Mr. Jack McCarthy Project:

Soils PO# 002332 Client Sample ID:

9807-0000-013F Project:

YANK01204 Sample ID:

173769006 Client ID:

YANK001 Matrix:

TS Vol. Recv.:

Collect Date:

14-SEP-06 Receive Date:

21-SEP-06 Collector:

Client Parameter Qualifier Result Uncertainty LC TPU MDA

'Units DF Analyst Date Time Batch Mtd Rad Liquid Scintillation Analysis LSC, Tritium Dist, Solid -

3 pCi/g

-0.875

+/-1.21 1.07

+/-1.21 2.30 pCi/g DFAI 10/15/06 0032 578364 1

The following Analytical Methods were performed Method Description EPA 906.0 Modified Notes:

The Qualifiers in this report are defined as follows:

A quality control analyte recovery is outside of specified acceptance criteria Result is less than value reported Result is greater than value reported A

The TIC is a suspected aldol-condensation product B

Target analyte was detected in the associated blank BD Results are either below the MDC or tracer recovery is low C

Analyte has been confirmed by GC/MS analysis D

Results are reported from a diluted aliquot of the sample H

Analytical holding time was exceeded J

Value is estimated N/A Spike recovery limits do not apply. Sample concentration exceeds spike concentration b'y 4X or more R

Sample results are rejected U

Analyte was analyzed for, but not detected above the MDL, MDA, or LOD.

UI Gamma Spectroscopy--Uncertain identification X

Consult Case Narrative, Data Summary package, or Project Manager concerning this qualifier Y

QC Samples were not spiked with this compound A

RPD of sample and duplicate evaluated using +/-RL. Concentrations are <5X the RL h

Preparation or preservation holding time was exceeded The above sample is reported on an "as received" basis.

24

GENERAL ENGINEERING LABORATORIES, LLC.

2040 Savage Road Charleston SC 29407 - (843) 556-8171 - www.gel.com Certificate of Analysis Company:

Connecticut Yankee Atomic Power Address :

362 Injun Hollow Rd..

East Hampton, Connecticut 06424 Report Date: October 18, 2006

Contact:

Mr. Jack McCarthy Project:

Soils PO# 002332 Client Sample ID:

9807-0000-014F Proiect:

YANK01204 SamplelD:

173769007 Client ID:

YANK001 Matrix:.

TS Vol. Recv.:

Collect Date:

18-SEP-06 Receive Date:

21-SEP-06 Collector:

Client Parameter Qualifier Result Uncertainty LC TPU MDA Units DF Analyst Date Time Batch Mtd Rad Liquid Scintillation Analysis LSC, Tritium Disi, Solid - 3 pCi/g Tritium U

-1.34

+/-1.28 1.16

+/-1.28 2.49 pCi/g DFA1 10115/06 0048 578364 1

The following Analytical Methods were performed Method Description EPA 906.0 Modified Notes:

The Qualifiers in this report are defined as follows:

A quality control analyte recovery is outside of specified acceptance criteria Result is less than value reported Result is greater than value reported A

The TIC is a suspected aldol-condensation product B

Target analyte was detected in the associated blank BD Results are either below the MDC or tracer recovery is low C

Analyte has been confirmed by GC/MS analysis D

Results are reported from a diluted aliquot of the sample H

Analytical holding time was exceeded J

Value is estimated N/A Spike recovery limits do not apply. Sample concentration exceeds spike concentration by 4X or more R

Sample results are rejected U

Analyte was analyzed for, but not detected above the MDL, MDA, or LOD.

UI Gamma Spectroscopy--Uncertain identification X

Consult Case Narrative, Data Summary package, or Project Manager concerning this qualifier Y

QC Samples were not spiked with this compound A

RPD of sample and duplicate evaluated using +/-RL. Concentrations are <5X the RL h

Preparation or preservation holding time was exceeded The above sample is reported on an "as received" basis.

25

QUALITY CONTROL DATA 26

GENERAL ENGINEERING LABORATORIES, LLC 2040 Savage Road Charleston SC 29407 - (843) 556-8171 - www.gel.com QC Summary Client:

Connecticut Yankee Atomic Power 362 Injun Hollow Rd Reuort Date: October 18, 2006 Page 1 of 2 East Hampton, Connecticut

Contact:

Mr. Jack McCarthy Workorder:

173769 Parmnname NOM Sample Qual QC Units RPD%

REC%

Range AnIst Date Time Rad Liquid Scintillation Batch 578364 QC1201205182 173770001 DUP Tritium QC1201205184 LCS Tritium QC1201205181 MB Tritium QC1201205183 173770001 MS Tritium U

1.60 U

Uncert:

+/-5.76 TPU:

+/-5.76

-1.29

+/-6.37

+/-6.37 9.95

+/-1.86

+/-1.86 pCilg 0

(0% - 100%) DFA I 10.4 Uncert:

TPU:

Uncert:

TPU:

57.8 U

Uncert:

TPU:

U

-0.187

+1-1.17

+/-1.17 pCi/g pCilg pCi/g 96 (75%-125%)

10/15/06 02:10 10/15/06 02:42 10/15/06 01:53 10/15/06 02:26 1.60

+/-5.76

+1-5.76 48.5

+/-9.94

+/-9.97 84 (75%-125%)

Notes:

The Qualifiers in this report are defined as follows:

A B

BD C

D H

J N/A R

U U'

X Y

hi A quality control analyte recovery is outside of specified acceptance criteria Result is less than value reported Result is greater than value reported The TIC is a suspected aldol-condensation product Target analyte was detected in the associated blank Results are either below the MDC or tracer recovery is low Analyte has been confirmed by GCIMS analysis Results are reported from a diluted aliquot of the sample Analytical holding time was exceeded Value is estimated Spike recovery limits do not apply. Sample concentration exceeds spike concentration by 4X or more Sample results are rejected Analyte was analyzed for, but not detected above the MDL, MDA, or LOD.

Gamma Spectroscopy--Uncertain identification Consult Case Narrative, Data Summary package, or Project Manager concerning this qualifier QC Samples were not spiked with this compound RPD of sample and duplicate evaluated using +/-RL. Concentrations are <5X the RL Preparation or preservation holding time was exceeded 27

GENERAL ENGINEERING LABORATORIES, LLC 2040 Savage Road Charleston SC 29407 - (843) 556-8171 - www.geLcom QC Summary Workorder:

173769 Page 2 of 2 Parmname NOM Sample Qual QC Units RPD%

REC%

Range AnIst Date Time

'N/A indicates that spike recovery limits do not apply when sample concentration exceeds spike conc. by a factor of 4 or more.

    • Indicates analyte is a surrogate compound.

^ The Relative Percent Difference (RPD) obtained from the sample duplicate (DUP) is evaluated against the acceptence criteria when the sample is greater than five times (5X) the contract required detection limit (RL). In cases where either the sample or duplicate value is less than 5X the RL, a control limit of +/- the RL is used to evaluate the DUP result.

For PS, PSD, and SDILT results, the values listed are the measured amounts, not final concentrations.

Wheore the analytical method has been performed under NELAP certification, the analysis has met all of the requirements of the NELAC standard unless qualified on the QC Summary.

28

SUBSURFACE AREA ASSOCIATED WITH THE SOUTHWEST SITE STORAGE AREA SURVEY UNIT 9807-0000 RELEASE RECORD ATTACHMENT 3 (DQA RESULTS)

SUBSURFACE AREA ASSOCIATED WITH THE SOUTHWEST SITE STORAGE AREA SURVEY UNIT 9807-0000 RELEASE RECORD ATTACHMENT 3A (PRELIMINARY DATA REVIEW)

PRELIMINARY DATA REVIEW FORM Survey Unit:

9807-0000 Survey Unit Name: Subsurface Area Associated with the Southwest Site Storage area Classification :

B Survey Media:

Soil Type of Survey:

Final Status Survey Type of Measurement:

Radionuclide Specific lumber of Measurements :

25 BASIC STATISTICAL QUANTITIES Cs-137 Target Level (pCi/g) 5.3 8E+00 Minimum Value:

-2.76E-02 Maximum Value:

3.50E+00 Mean :

1.49E-01 Median :

8.18E-03 Standard Deviation:

6.98E-01 Sample Identification 9807-0000-001 F 9807-0000-002F 9807-0000-003F 9807-0000-004F 9807-0000-005F 9807-0000-006F 9807-0000-007F 9807-0000-008F 9807-0000-009F 9807-0000-01OF 9807-0000-01 IF 9807-0000-012F 9807-0000-013F 9807-0000-014F 9807-0000-015F 9807-0000-016F 9807-0000-017F 9807-0000-018F 9807-0000-019F 9807-0000-020F Reported Results Cs-137 Concentration (pCi/g)

-7.91E-03

-2.76E-02 4.02E-02

- 1.26E-03 1.87E-02

-8.34E-03

- 1.54E-02

-1.36E-02 3.30E-02 2.86E-02

-2.32E-02 4.36E-02

-2.5 1E-03 8.18E-03 1.29E-02 6.01E-03 3.34E-02 2.39E-03

-3.24E-04 3.53E-02 Fraction of Detect?

Target Level

-0.001

-0.005 0.007 0.000 0.003

-0.002

-0.003

-0.003 0.006 0.005

-0.004 0.008 0.000 0.002 0.002 0.001 0.006 0.000 0.000 0.007 Submitted by/Date o

1 of 1

PRELIMINARY DATA REVIEW FORM Sample Identification 9807-0000-021F 9807-0000-022F 9807-0000-023F 9807-0000-024F 9807-0000M025F Reported Results Cs-137 Concentration (pCi/g) 0.00E+00 2.88E-02 2.56E-02 1.18E-02 3.50E+00 Fraction of Detect?

Target Level 0.000

+

0.005

+

0.005 0.002

+

0.651 Submitted by/Da2o 2 ofl1

SUBSURFACE AREA ASSOCIATED WITH THE SOUTHWEST SITE STORAGE AREA SURVEY UNIT 9807-0000 RELEASE RECORD ATTACHMENT 3B (GRAPHICAL REPRESENTATION OF DATA)

FREQUENCY PLOT FOR CESIUM-137 Survey Unit: 9807-0000 Subsurface.Area Associated with the Survey Unit Name: Southwest Site Storage Area Mean: 1.49E-01 pCi/g Frequency Plot For Cs-137 25 20

= 15 Er 10 U-5 0

-2.76E-02 8.47E-01 1.72E+00 2.60E+00 3.47E+00 4.35E+00 Upper End Value (pCilg)

Upper End Observation Observation Value Frequency Frequency

-2.76E-02 1

4%

8.47E-01 23 92%

1.72E+00 0

0%

2.60E+00 0

0%

3.47E+00 0

0%

4.35E+00 1

4%

Total:

25 100%

Submitted by/Da/e

/I 1J21 job RevittJdbID yIte 1o 1 of 1

QUANTILE PLOT FOR CESIUM-137 Survey Unit:

9807-0000 Subsurface Area Associated with the Survey Unit Name: Southwest Site Storage Area Mean:

1.49E-01 pCi/g Quantile Plot For Cs-1 37 0) 0.

C-)

3.47E+00 2.97E+00 2.47E+00 1.97E+00 1.47E+00 9.70E-01 4.70E-01

-3. OOE-02 0

10 20 30 40 50 60 70 80 90 100 Percentage Cs-137 Rank Percentage

-2.76E-02 1

3%

-2.32E-02 2

10%

-1.54E-02 3

17%

-1.36E-02 4

23%

-8.34E-03 5

30%

-7.91 E-03 6

37%

-2.51 E-03 7

43%

-1.26E-03 8

50%

-3.24E-04 9

57%

0.00E+00 10 63%

2.39E-03 11 70%

6.01E-03 12 77%

8.18E-03 13 83%

1.18E-02 14 90%

1.29E-02 15 97%

1.87E-02 16 97%

2.56E-02 17 97%

2.86E-02 18 97%

2.88E-02 19 97%

3.30E-02 20 97%

3.34E-02 21 97%

3.53E-02 22 97%

4.02E-02 23 97%

4.36E-02 24 97%

3.50E+00 25 97%

Submitted by/Datv i

-t

/

iiIziIoe;o Revi~<~d by/)~ate

SUBSURFACE AREA ASSOCIATED WITH THE SOUTHWEST SITE STORAGE AREA SURVEY UNIT 9807-0000 RELEASE RECORD ATTACHMENT 3C (SIGN TEST)

Connecticut Yankee Decommissioning Project Health Physics Procedure GPP-GGGR-R5121-001 Attachment A, Rev CY-001 MAJOR Sign Test Calculation Sheet For A Single Radionuclide or Gross Activity Measurements Survey Area Number: 9807 Survey Unit Number: 0000 Survey Area Name: Subsurface Area associated with the Southwest Site Storage Area WPIR#: 2006-0038 Classification: B Type I (cx error): 0.05 (N): 25 Radionuclide: Cs-137 DCGL: 5.38 Results (pCi/g)

DCGL - Results Sign

-7.9 1E-03 5.39E+00

-2.76E-02 5.41E+00 1

4.02E-02 5.34E+00 I

-1.26E-03 5.38E+O0 1

1.87E-02 5.36E+00

-8.34E-03 5.39E+00

-1.54E-02 5.40E+00

-1.36E-02 5.39E+00 1

3.30E-02 5.35E+00 2.86E-02 5.35E+00 I

-2.32E-02 5.40E+00 1

4.36E-02 5.34E+00 1

-2.51E-03 5.38E+00 8.18E-03 5.37E+00 1.29E-02 5.37E+00 1

6.01E-03 5.37E+00 1

3.34E-02 5.35E+00 2.39E-03 5.38E+00 1

-3.24E-04 5.38E+00 1

3.53E-02 5.34E+00 Page 1 of I

Connecticut Yankee Decommissioning Project Health Physics Procedure GPP-GGGR-R5121-001 Attachment A, Rev CY-001 MAJOR Survey Area Number: 9807 Survey Unit Number: 0000 Survey Area Name: Subsurface Area associated with the Southwest Site Storage Area WPIR#: 2006-0038 Classification: B Type I (cc error): 0.05 (N): 25 Radionuclide: Cs-137 DCGL: 5.38 Results (pCi/g)

DCGL - Results Sign 0.OOE+00 5.38E+00 1

2.88E-02 5.35E+00 1

2.56E-02 5.35E+00 1

1.18E-02 5.37E+00 1

3.50E+00 1.88E+00 1

Number of positive differences (S+): 25 Critical Value: 17 Performed by:

Independent Review Survey Unit Meets Acceptance Criterion Date:

/A!/o 6 Date:

ii/z, ao0.

\\

Page 1 of 1

SUBSURFACE AREA ASSOCIATED WITH THE SOUTHWEST SITE STORAGE AREA SURVEY UNIT 9807-0000 RELEASE RECORD ATTACHMENT 3D (QC SPLIT RESULTS)

Health Phvsics Procedure 24265-000-GPP-GGGR-R5]24-000-Rev.CY-000 Attachment A HelhPAisPoeue-46-0-P-GRR 4O0-e.Y00Atcmn Split Sample Assessment Form Survey Area#: 9807 Survey.Unit #: 0000 Survey Unit name: Subsurface Area Associated with the Southwest Site Storage Area Sample Plan or WPIR#: 2005-0038 IvSML#: 9807-0000-012 Sample

Description:

ComparisonDof split samples collected from sample measurement Plocation#12 and analyzed using gamma spectroscopy by off-site Vendor Laboratory.

The standard sample was 9807-0000-0012F, the comparison sample was 9807-0000-012F5.

STANDARD COMPARISON Radionuclide Activity Standard Resolution Agreement Activity Standard Comparison Acceptable Value Error Range Value Error Ratio (YIN)

K-40 13.9 5.65E-1 25 0.75 -1.33 13.7 5.70E-1 0.99 Y

Comments/Corrective Actions: Not enough Cs-137 to yield an acceptable Resolution Table is provided to show acceptance criteria used to assess split samples.

Resolution 4-7 8-15 16-50 51-200

>200 Agreement Range 0.5 -2.0 0.6 - 1.66 0.75 - 1.33 0.80 - 1.25 0.85-1.18 ormed By:

/

2

(

Page 1 of 1

Health Physics Procedure 24265-000-GPP-GGGR-R5124-000-Rev.CY-000 Attachment A Health Physics Procedure 24265-000-GPP-GGGR-R5 124-000-Rev.CY-000 Attachment A Split Sample Assessment Form Survey Area#: 980.7 Survey Unit #: 0000 Survey Unit name: Subsurface Area Associated with the Southwest Site Storage Area Sample Plan or WPIR#: 2005-0038 SML#: 9807-0000-018 Sample

Description:

Comparison of split samples collected from sample measurement-location #18 and analyzed using gamma spectroscopy by off-site Vendor Laboratory. The standard sample was 9807-0000-018F, the comparison sample was 9807-0000-01FS.

STANDARD COMPARISON Radionuclide Activity Standard Resolution Agreement Activity Standard Comparison Acceptable Value Error Range Value Error Ratio (YIN)

K-40 13.2 5.55E-1 24 0.75-1.33 13.3 6.05E-1 1.00 Y

Comments/Corrective Actions: Not enough Cs-137 to yield an acceptable Resolution Table is provided to show acceptance criteria used to assess split samples.

Resolution 4-7 8-15 16 -50 51 -200

>200 Agreement Range 0.5 -2.0 0.6 - 1.66 0.75 - 1.33 0.80 - 1.25 0.85-1.18 C_/-- Ie'6,¢'---

I Page 1 of I

Health Physics Procedure 24265-000-GPP-GGGR-R5124-000-Rev.CY-000 Attachment A Health Physics Procedure 24265-000-GPP-GGGR-R5 1 24-000-Rev.CY-000 Attachment A Split Sample Assessment Form Survey Area#: 9807 Survey Unit #: 0000 Survey Unit name: Subsurface Area Associated with the Southwest Site Storage Area Sample Plan or WPIIR#: 2005-0038 SML#: 9807-0000-024 Sample

Description:

Comparison of split samples collected from sample measurement location #24 and analyzed using gamma spectroscopy by off-site Vendor Laboratory. The standard sample was 9807-0000-024F, the comparison sample was 9807-0000-024FS.

STANDARD COMPARISON Radionuclide Activity Standard Resolution Agreement Activity Standard Comparison Acceptable Value Error Range Value Error Ratio (Y/N)

K-40 12.1 5.40E-1 22 0.75-1.33 13.6 4.68E-1 1.12 Y

t I

I F

+/-

F F

F 4

+

F

+

4 F

+

F 4

+

F 4-4 F

Comments/Corrective Actions: Not enough Cs-137 to yield an acceptable Resolution Table is provided to show acceptance criteria used to assess split samples.

R1solution 4-7 8-15 16-50 51 -200

>200 Agreement Range 0.5 -2.0 0.6 - 1.66 0.75 - 1.33 0.80 - 1.25 0.85-1.18

/

Page 1 of I

SUBSURFACE AREA ASSOCIATED WITH THE SOUTHWEST SITE STORAGE AREA SURVEY UNIT 9807-0000 RELEASE RECORD ATTACHMENT 3E (COMPASS DQA WITH POWER CURVE)

~DQA Surface Soil Report A s.s.e_ _s.s.me nt. s u. m m a ry Site:

Planner(s):

Survey Unit Name:

Report Number:

Survey Unit Samples:

Reference Area Samples:

Test Performed:

Judgmental Samples:

Assessment

Conclusion:

9807-0000 FSS McCarthy Subsurface Area Associated with the Southwest Site 1

25 0

Sign Test Result:

Not Performed 0

EMC Result:

Not Performed Reject Null Hypothesis (Survey Unit PASSES)

Retrospective Power Curve

=

I-1 0.9 0.8 0.7 0.6 0.5 0.4 0.3 0.2 0,1 0

t--

0 Soil Prospective Power LBGR.

DCGL 2

3 4

5 Concentration (p Ci/g), including background M

1-beta Actual Power Estimated Power

,Retrospecti.,e Power 6

COMPASS vl.0.0 11t/20/2006 Page I