Fina Status Survy Final Report Phase V December 2006
CYAPCO FINAL STATUS SURVEY RELEASE RECORD CENTRAL PENINSULA SURVEY UNIT 9530-0004 Prepared By:
FSS Enginedr Reviewed B 7w Date:
/
Date:I Date: 11/2 /
,6 iSS Engine r Technical Support Manager Approved By:
Revision 0
CENTRAL PENINSULA SURVEY UNIT 9530-0004 RELEASE RECORD TABLE OF CONTENTS
- 1.
SURVEY UNIT DESCRIPTION.......................................................
3
- 2.
CLA SSIFICATION BA SIS................................................................
3
- 3.
DATA QUALITY OBJECTIVES (DQO).....................
5
- 4.
SU R V EY D E SIG N.............................................................................
8
- 5.
SURVEY IMPLEMENTATION.......................................................
11
- 6.
SU RV EY RESU LTS.........................................................................
12
- 7.
QUALITY CONTROL.................................
15
- 8.
INVESTIGATIONS AND RESULTS.............................................
15
- 9.
REMEDIATION AND RESULTS..................................................
16
- 10. CHANGES FROM THE FINAL STATUS SURVEY PLAN......
16
- 11.
DATA QUALITY ASSESSMENT (DQA).......................................
16
- 12. A N O M A LIE S...................................................................................
17
- 13. C O N C LU SIO N.................................................................................
17
- 14. A TTA C H M EN TS.............................................................................
18 14.1 Attachment I - Figures (6 pages including cover) 14.2 Attachment 2 - Scan Results (5 pages including cover) 14.3 Attachment 3 - Laboratory Data (108 pages including cover) 14.4 Attachment 4-DQA Results (13 pages including covers)
TOTAL 150 Revision 1
CENTRAL PENINSULA SURVEY UNIT 9530-0004 RELEASE RECORD
- 1.
SURVEY UNIT DESCRIPTION Survey Unit 9530-0004 (Central Peninsula) is designated as Final Status Survey (FSS) Class 3 and consists of 83,777 m2 (21 acres) of uninhabited open land located approximately 2,100 feet from the reference coordinate system benchmark used at Haddam Neck Plant (HNP) (see Attachment 1). The survey unit is bounded as follows: land Survey Unit 9520-0003 to the north (called north as oriented with the north to south flow of the Connecticut River), the Discharge Canal to the east, land Survey Unit 9531-0000 to the south, and the Connecticut River to the west. The survey unit is relatively level open space in the middle of the peninsula.
The restoration of the peninsula for FSS has removed some surface interference in the survey unit.
The reference coordinates associated with this survey unit are E007 through E029 by S095 through S131 (refer to License Termination Plan (LTP) Section 5.4.4).
The reference coordinates provide the maximum dimensions of a rectangle containing this survey unit. Some areas contained in this rectangle may not be part of this survey unit. The boundary of the survey unit was defined using a Global Positioning System (GPS) based on the Connecticut State Plane System North American Datum (NAD) 1927.
- 2.
CLASSIFICATION BASIS The survey unit was classified in accordance with Procedure RPM 5.1-10, "Survey Unit Classification. " The historical information, scoping analyses and characterization results provided sufficient data to designate Survey Unit 9530-0004 as Class 3 in September 2006.
The "Classification Basis Summary" conducted for Survey Unit 9530-0004 consisted of:
a) A review of the 10CFR50.75 (g) (1) database, b) A review of the "Initial Characterization Report" and the "Historic Site Assessment Supplement,"
c) Historic and current survey records review, d) Visual inspections and a "walkdown."
A review of the IOCFR50.75(g)(1) database report identified two documents associated with this survey unit.
-Northeast.-Utilities-Radiological--Assessment -Branch-memo NE-86-RA--
1142: Relates to dredging of two areas of the Discharge Canal to support the Low Pressure Turbine replacement project. Spoils from dredging were relocated to this survey unit and adjacent survey unit 9530-0002.
b) Plant Information Report (PIR) 89-35 and related surveys: Documents the discovery of radioactive spoils that were deposited on the peninsula in 1989 following removal from the outfall area outside the Revision 0 3
Revision 0 3
CENTRAL PENINSULA SURVEY UNIT 9530-0004 RELEASE RECORD Radiologically Controlled Area (RCA). Once identified, the spoils were removed according to the surveys.
c) Condition Report (CR) 06-0089: Documents the discovery of a buried drum containing radioactive material in Survey Unit 9530-0004.
The materials were removed from the peninsula.
A review of the "Initial and Supplemental Characterization Reports" as well as the previous "Classification Basis Summaries" was performed.
Survey Unit 9530-0004 was initially designated as Class 3 during the development of the LTP. The source documents, the "Connecticut Yankee Haddam Neck Characterization Report" and "Initial Classification for Survey Areas at Connecticut Yankee", were incorporated by reference in LTP revision 0 (references 2-2 and 2-7 respectively). The second source document justified a Class 2 designation for those areas for which there was historical evidence of contamination above the Derived Concentration Guideline Levels (DCGLs -
refer to Section 2 for definition and description of DCGL), but for which recent surveys had shown that decontamination efforts had occurred and that the radiological conditions were expected to be below the DCGLs. Additional justification for a Class 3 designation based on survey and sampling data was provided as another reference to the LTP by the "Haddam Neck Plant Historical Site Assessment Supplement".
The survey unit had undergone FSS in the fall of 2004 and release records documenting the satisfactory completion of the FSS objectives were in preparation.
In 2006, utilities were being removed as part of the decommissioning effort on the Upper Peninsula.
Construction debris including Asbestos Containing Material (ACM) was identified and remediated. In addition to the ACM, several objects were also identified that had detectable radioactivity. Two pieces of angle iron were located in a water utility trench in Survey Unit 9530-0004. Based on the potential to change the final radiological status of the survey unit, another FSS was considered prudent to define the as-left radiological condition.
Soil samples were collected in 2006 to establish the radiological condition of the surface and subsurface area following removal of soil. Cs-137 was the only gamma emitting radionuclide reported in concentrations with the potential for exceeding the screening criteria. Therefore, the previous FSS data and statistical parameters were used for the survey design. Statistical
--quantities--from-the-previous FS S-survey-are provided-in-Table-1-....--
Revision 0 4
Revision 0 4
CENTRAL PENINSULA SURVEY UNIT 9530-0004 RELEASE RECORD Minimum Observed Concentration (pCi/g):
0.00E+00 Maximum Observed Concentration (pCi/g):
3.59E-01 Mean (pCi/g):
1.35E-01 Median (pCi/g):
1.27E-01 Standard Deviation (pCi/g):
8.79E-02 The FSS Engineer performed a visual inspection and walk-down during August 2006 to assess the physical condition of the survey unit, evaluate access points and travel paths and identify potentially hazardous conditions.
This survey area is affected by existing groundwater (reference CY memo ISC 06-024) which will be a source of dose from residual radioactivity, as discussed in Section 3 under the Data Quality Objectives.
Based upon the previous FSS survey and sampling and the results of radiological surveys performed during the radiological assessment, it was concluded that there was a low probability for residual radioactivity to be present in this survey unit justifying a final survey unit classification of Class 3 (refer to Section 3).
- 3.
DATA QUALITY OBJECTIVES (DQO)
FSS design and planning used the Data Quality Objective (DQO) process as described by the LTP, Procedure RPM 5.1-11, "Preparation of Final Status Survey Plan, " and the "Multi-Agency Radiation Survey and Site Investigation Manual" (MARSSIMv). A summary of the main features of the DQO process are provided herein.
The DQO process incorporated hypothesis testing and probabilistic sampling distributions to control decision errors during data analysis. Hypothesis testing is a process based on the scientific method that compares a baseline condition to an alternate condition. The baseline condition is technically known as the null hypothesis. Hypothesis testing rests on the premise that the null hypothesis is true and that sufficient evidence must be provided for rejection. In designing the survey plan, the underlying assumption, or null hypothesis was that residual activity in the survey unit exceeded the release criteria. Rejection of the null hypothesis would indicate that residual activity within the survey unit does not
- exceed the--release-criteria:-Therefore, the'survey-unit-does-satisfy the-primary objective of the FSS plan.
The primary objective of the FSS plan was to demonstrate that the level of residual radioactivity in Survey Unit 9530-0004 did not exceed the release criteria specified in the LTP and that the potential dose from residual radioactivity is As Low As Reasonably Achievable (ALARA).
Revision 0 5
CENTRAL PENINSULA SURVEY UNIT 9530-0004 RELEASE RECORD A fundamental precursor to survey design is to establish a relationship between the release criteria and some measurable quantity. This is done through the development of DCGLs. The DCGLs represent average levels of radioactivity above background levels and are presented in terms of surface or mass activity concentrations. Chapter 6 of the LTP describes in detail the modeling used to develop the DCGLs for soil (called Base Case Soil DCGL), existing groundwater radioactivity and future groundwater radioactivity that will. be contributed by building basements and footings.
The DCGLs presented in Chapter 6 of the LTP were developed for exposures from three (3) components, that is, residual radioactivity in soil, existing groundwater radioactivity, and future groundwater radioactivity from the burial of concrete foundations or footings from site buildings containing residual radioactivity.
Equation I shows the mathematical relationship between the three (3) components and the total dose.
Equation 1 HTotal =H Soil +HExcistingGW +HFUiUreGW The total dose under the LTP criteria is twenty-five (25) mrem/yr TEDE from all three (3) components.
The allowable total dose under the Connecticut Department of Environmental Protection (CTDEP) radiological remediation standard for CY is nineteen (19) mrem/yr TEDE. To satisfy both the LTP and CY CTDEP criteria, the dose from soil must be reduced when using the existing and future groundwater dose values discussed above.
This survey area is affected by existing groundwater (reference CY memo ISC 06-024).
Therefore, the dose contribution from existing groundwater is bounded by two (2) mrem/yr TEDE.
This survey unit is not considered impacted by future groundwater radioactive contamination, as there are no buried concrete foundations or footings containing residual radioactive material within the groundwater saturated zone in the area (reference CY memo ISC 06-024). The dose contribution from future groundwater, the third dose component is, therefore, zero (0) mrem/yr TEDE.
...............E q u a tio n -2....
19 mrem/yrTotal = 17 mrem/yrsoil + 2 mrem/yrExisting GW+ 0 nmrem/yrFutureGW The allowable dose for soil in this survey unit is seventeen (17) mrem/yr TEDE as shown by Equation 2 above.
The concentration of residual radioactivity resulting in seventeen (17) mrem/yr TEDE is designated as the Revision 0 6
Revision 0 6
CENTRAL PENINSULA SURVEY UNIT 9530-0004 RELEASE RECORD Operational DCGL, and has been established for the radionuclides of concern as provided in Table 2.
Tabl 2 WRfifiiilid -S'eciiic Base onlD vr p
E A
AD C
ý H-3 4.12E+02 2.80E+02 1.65E+O I C-14 5.66E+00 3.85E+00 2.26E-01 Mn-54 1.74E+01 1.18E+01 6.96E-01 Fe-55 2.74E+04 1.86E+04 1.1OE+03 Co-60 3.81 E+00 2.59E+00 1.52E-01 Ni-63 7.23E+02 4.92E+02 2.89E+O1 Sr-90 I.55E+00 1.05E+00 6.20E-02 Nb-94 7.12E+00 4.84E+00 2.85E-01 Tc-99 1.26E+O1 8.57E+00 5.04E-01 Ag-108m 7.14E+00 4.86E+00 2.86E-01 Cs-134 4.67E+00 3.18E+00 1.87E-01 Cs-137 7.91E+00 5.38E+00 3.16E-0I Eu-152 1.01E+01 6.87E+00 4.04E-01 Eu-154 9.29E+00 6.32E+00 3.72E-0I Eu-155 3.92E+02 2.67E+02 1.57E+01 Pu-238 2.96E+01 2.0]E+01 1.18E+00 Pu-239/240 2.67E+01 1.82E+01 1.07E+00 Pu-241 8.70E+02 5.92E+02 3.48E+O1 Am-241 t
- 2.58E+01 1.75E+01 1.03E+00 Cm-243/244 2.90E+01 1.97E+0O1 1.16E+00 (1) Bold indicates those radionuclides considered to be Hard-to-Detect (HTD)
(2) The Base Case Soil DCGLs for soil are specified by the LTP in Chapter 6 and are equivalent to 25 mrem/yr TEDE (3) The Operational DCGL is equivalent to 17 mrem/yr TEDE (4) The required MDC is equivalent to I mrem/yr TEDE (5) Americium-241 can be analyzed by gamma and alpha spectroscopy and is considered to be Easy to Detect (ETD); the preferred result is the alpha spectroscopy's when both analyses
-. -are -performed-..
Another important facet of the DQO process is to identify the radionuclides of concern and determine the concentration variability.
Soil samples were collected in 2006 to establish the radiological condition of the surface and subsurface area following removal of soil.
Cs-137 was the only gamma emitting radionuclide reported in concentrations with the potential for Revision 0 7
Revision 0 7
CENTRAL PENINSULA SURVEY UNIT 9530-0004 RELEASE RECORD
- exceeding the screening criteria.
The previous FSS data and statistical parameters were used for the survey design and are provided in Table 1.
Instrument DQOs included a verification of the ability of the survey instrument to detect the radiation(s) of interest relative to the DCGL. Survey instrument response checks were required prior to issue and after the instrument had been used. Control and accountability of survey instruments was required to assure the quality and prevent the loss of data.
As part of the DQOs applied to laboratory processes, analysis results were reported as actual calculated results. Results reported as less than Minimum Detectable Concentration (MDC) were not accepted for FSS.
Sample report summaries included unique sample identification, analytical
- method, radionuclide, result, and uncertainty to two (2) standard deviations, laboratory data qualifiers, units, and the required and observed MDC.
- 4.
SURVEY DESIGN The level of effort associated with planning a survey is based on the complexity of the survey and nature of the hazards. Guidance for preparing FSS plans is provided in Procedure RPM 5.1-11, "Preparation of Final Status Survey Plans".
The FSS plan uses an integrated sample design that combines scanning surveys and sampling which can be either random or biased.
The DQO process determined that Cs-137 would be the radionuclide of concern in survey unit 9530-0004 (refer to Section 3). Other radionuclides identified during this FSS would be evaluated to ensure adequate survey design.
Surrogate DCGLs were not required for this survey unit based the previous FSS of this survey unit and via screening under LTP Section 5.4.7.2, "Gross Activity DCGLs".
Radionuclide screening or de-selection is a process where an individual radionuclide or aggregates may be considered insignificant and eliminated from the FSS. The criteria for de-selection are concentrations less than 5% for individual radionuclides and less than 10% for aggregates.
The Elevated Measurement Comparison (EMC) did not apply to this survey unit since it is a Class 3 area and discrete, elevated areas of contamination were not expected.
The Sign Test was selected as the non-parametric statistical test. The use of the Sign Test did not require the selection or use of a background reference area,
.which--simplified--survey--design--and-implementation.
.-.-This-approach--was-conservative since it included background Cs-137 as part of the sample set.
The number of soil samples for FSS was determined in accordance with Procedure RPM 5.1-12, "Determination of the Number of Surface Samples for Final Status Survey." The Lower Bound of the Gray Region (LBGR) was set in accordance with Procedure RPM 5.1-11 to 5.2 to maintain the relative shift (A/a) in the range of 1 and 3. The resulting Adjusted Relative Shift was 2.0. A Prospective Power Curve was generated using COMPASS, a software package Revision 0 8
CENTRAL PENINSULA SURVEY UNIT 9530-0004 RELEASE RECORD developed under the sponsorship of the United States Nuclear Regulatory Commission (USNRC) for implementation of the MARSSIM in support of the decommissioning license termination rule (10 CFR 20, Subpart E). The result of the COMPASS computer run showed adequate power for the survey design.
The survey design specified fifteen (15) surface soil samples for non-parametric statistical testing and three (3) samples at biased locations.
The grid patternmand locations of the soil samples were determined using Visual Sample Plan (VSP) in accordance with Procedure RPM 5.1-14, "Identifying, and Marking Surface Sample Locations for Final Status Survey."
Visual Sample Plan was created by Pacific Northwest National Laboratory (PNNL) for the United States Department of Energy. A simple random grid pattern was selected for sample design, which is appropriate for a Class 3 area.
Judgmental sampling was included as a feature of this survey design to account for any anomalies potentially identified in the field.
Sample locations were identified using AutoCAD-LT, a commercially available plotting software package with coordinates consistent with the Connecticut State Plane System. These coordinates were integrated with a GPS to locate sample locations in the field. Sample Measurement Locations for the design are listed with the GPS coordinates in Table 3.
Tabe 3Sanpl Mesuemet Lcaion wih ssociate GPS Cories~
Kfle~~i~itaiionNo thi~ng~
~
Eatn 9530-0004-QOIF 235541.47 670598.82 9530-0004-002F 234944.02 671206.69 9530-0004-003F 235686.66 670461.14 9530-0004-004F 235460.41 670198.49 9530-0004-005F 235117.37 671475.79 9530-0004-006F 235060.02 671089.08 9530-0004-007F 235098.53 671618.08 9530-0004-008F 235647.77 670439.26 9530-0004-009F 235495.35 670286.78 9530-0004-OIOF 234781.85 671612.51 9530-0004-01 IF 235349.12 671394.90
....... 953.0m0004-012F --
_235334. ----------
671690.05-- ----------
9530-0004-013F 235377.04 670495.72 9530-0004-014F 235151.08 670679.98 9530-0004-015F 234980.04 671035.21 9530-0004-016F 235393.38 670801.87 9530-0004-017F 235267.83 670828.77 9530-0004-018F 235234.29 670925.74 Revision 0 9
Revision 0 9
CENTRAL PENINSULA SURVEY UNIT 9530-0004 RELEASE RECORD Procedure RPM 5.1-11 specifies that 5% of the samples are required to be selected for HTD analysis. Two (2) soil samples, or about 10% of the number of samples that would be used for non-parametric statistical testing were randomly selected for HTD radionuclide analysis using the Microsoft Excel "RANDBETWEEN" function. Each sample was sent off-site for a full suite analysis of the HTD radionuclides specified in the LTP, Table 2-12, "Radionuclides Potentially Present at Haddam Neck Plant" and as provided in Table 2.
The implementation of quality control measures as referenced by Procedure RPM 5.1-24, "Split Sample Assessment for Final Status Survey," included the collection of two (2) soil samples for "split sample" analysis by the off-site laboratory. These locations were selected randomly using the Microsoft Excel "RANDBETWEEN" function. The number of quality control soil samples was about 10% of fifteen (15) samples.
The LTP specifies a judgmental scanming coverage for outdoor Class 3 areas.
The fraction of scanning coverage was determined during the DQO process with the total amount and location(s) based on the likelihood of finding elevated activity during FSS.
Based on the historical site assessment, the characterization data available, and the use of the survey unit to store spoils from remediation, it was determined that scanning was required in two (2) separate areas. The total surface area to be scanned was approximately 5% of the survey unit. A map of the scan grid locations is provided in Attachment 1.
For this Class 3 survey unit, the "Investigation Level" for area scanning and soil sample measurement results are those levels specified in LTP, Table 5-8. Table 4 provides a synopsis of the survey design.
-~
Table.4_1_Synopsis o4t6 Srvey DeDsign i
FeAtu ret CJ Ler~iaz Survey Unit Land Area 83,777 m-Based on AutoCAD-LT Type 1 and Type 2 errors were 18 0.05, sigma was 0.088 pCi/g, Number of Measurements (15 systematic grid)'
the LBGR was adjusted to 5.2 (3 biased) to maintain Relative Shift in the range of I and 3
-G--ridSpacing NA Not applicable for a Class 3
_..survey unit-........
Operational DCGL 5.3 8 pCi/g Cs-137 Administratively set to achieve 17 mrem/yr TEDE ()
A sample result that exceeds Soil Investigation Level 2.69 pCi/g Cs-137 50% of the Operational DCGL meets the LTP criteria for a Class 3 survey unit Revision 0 10
CENTRAL PENINSULA SURVEY UNIT 9530-0004 RELEASE RECORD
~~~ab 4 - $osisotheSre Y.,
gy Scan Survey Area Approximately 5%
The LTP specifies judgmental eof the area coverage for Class 3 Survey Units Detectable over Administratively set to achieve background 17 mrem/yr TEDE o (1) The allowable dose for soil in this survey unit is 17 mrem/yr TEDE as the bounding dose from existing and future groundwater has been established based on field data (reference CY memo ISC 06-024.)
- 5.
SURVEY IMPLEMENTATION Final Status Survey field activities were conducted under Work Plan and Inspection Record (WP&IR) 2006-0038.
The WP&IR package included a detailed FSS plan, job safety analysis, job planning checklist and related procedures for reference.
Daily briefings were conducted to discuss the expectations for job performance and the safety aspects of the survey.
The "Daily Survey Journal" was used to document field activities and other information pertaining to the FSS.
Two (2) scan areas were established that constituted approximately 5% of the surface area of Survey Unit 9530-0004.
Grid lines, one meter wide, were painted on.the ground of the scan area. A background survey was performed around the survey unit and it was determined that, using an Eberline E-600 with a SPA-3 sodium iodide detector, background ranged from 6,080 counts per minute (cpm) up to 8,440 cpm.
The scan areas were established and scanned for elevated readings (see for all scan results). Scanming was performed with an Eberline E-600 using a SPA-3 sodium iodide detector. The E-600 was operated in the rate-meter mode and used with audio response. The probe was positioned as close to the ground as possible and was moved at a scan speed of about 0.5 meters per second. Approximately 5% of the survey unit was scanned.
Measurement locations were identified in North American Datum (NAD) 1927 coordinates using GPS coordinates; sample locations were identified and marked with a surveyor's flag or paint for identification.
At each sample location, a one (1) meter radius around the sample flag or paint mark was scanned-for elevated radiatioritevels....
Twenty-five (25) surface soil samples were collected and packaged in accordance with Haddam Neck Plant (HNP) Procedure RPM 5.1-3, "Collection of Sample Media for Final Status Survey" and FSS design.
Samples were controlled, transported, stored, and transferred to the off-site laboratory using Chain-of-Custody (COC) protocol in accordance with Procedure RPM 5.1-5, "Chain of Custody for Final Status Survey Samples."
Revision 0 11 Revision 0 11
CENTRAL PENINSULA SURVEY UNIT 9530-0004 RELEASE RECORD Two (2) samples (9530-0004-003F and 9530-0004-012F) were randomly selected for HTD radionuclide analysis.
The implementation of survey specific quality control measures included the collection of two (2) samples (9530-0004-004F and 9530-0004-009F) for "split sample" analysis.
- 6.
SURVEY RESULTS All field survey activities were conducted between August 24, 2006 and September 6, 2006.
The sample locations identified in the FSS plan were scanned over approximately a one (1) meter radius for elevated radiation levels. Table 5 provides an overview of the scan results for sample measurement locations.
Scan results are provided in Attachment 2.
Tab*-- 5 -. can5 Res fScý
-r 6
sample Measuremen -Locations-Hihet oged Action tevel.
2 Mesueen ad i~nc-
>~Action Le~vel'(-
1 8.39 8.36 YES 2
6.70 8.86 NO 3
7.84 9.19 NO 4
6.60 7.62 NO 5
6.58 8.04 NO 6
7.26 7.47 NO 7
6.37 7.87 NO 8
7.24 8.95 NO 9
7.54 8.21 NO 10 6.92 7.38 NO 11 6.97 9.45 NO 12 8.09 8.55 NO
...1 3.................... 6 _9 2......
.7.2 "4 -
N 0........
14 6.46 6.94 NO 15 5.59 7.48 NO 16 7.38 7.97 NO 17 7.78 8.26 NO Revision 0 12
CENTRAL PENINSULA SURVEY UNIT 9530-0004 RELEASE RECORD esuirernent~~~edi
~
~
c~n cinLvI t~
18 8.23 9.21 NO 19 6.23 6.52 NO (1) The action level is based on a measurement above ambient background in accordance with the FSS plan (2) The FSS plan requires movement of the sample measurement location to the area within the 1 meter radius yielding the response above the action level The scan areas, that comprised approximately 5% of the total surface area for the survey unit, were scanned for elevated radiation levels. The areas were scanned in accordance with the FSS plan on August 24, 2006 and September 6, 2006.
Several elevated measurement locations were identified during scanning.Table 6 provides an overview of the scan area survey. Scan results are provided in Attachment 2.
_______Table,6,-
Scani Area Resuilts
>Highest
'lead IScan Logg.Iied ActiooLnvcl In vestigation Airea
~Reading Reading.
()
,Sample-1,'(kcpm)
Identification(2 9530-04-ER 9530-0004-020F 16-1 9530-04-ER-Ol -
9530-0004-021F 17-1 9530-04-ER 9530-0004-022F 1
10.3 8.44 23-1 9530-04-ER 9530-0004-023F 23-2 9530-04-ER 9530-0004-024F
. 24-1 9530-04-ER 9530-0004-025F 26-I 2
8.42 8.31 9530-04-SC 9530-0004-019F 1__ __* 05-0 (1) The action level is based on a measurement above ambient background
......(2).ERand.SC-.are..abbreviations..associated.with-the..barcodes-used in-the field-where-ER--
stands for Elevated Reading and SC stands for Scan' The off-site laboratory employed for the radiological analyses of samples was General Engineering Laboratories, LLC. The laboratory analyzed the fifteen (15) samples collected for non-parametric statistical testing, the associated field splits, the three (3) biased samples, and the seven (7) confirmatory samples using gamma spectroscopy. Gamma spectroscopy analysis was performed to the required MDCs. Gamma spectroscopy results identified some radionuclides Revision 0 13 Revision 0 13
CENTRAL PENINSULA SURVEY UNIT 9530-0004 RELEASE RECORD meeting the accepted criteria for detection (i.e., a result greater than two standard deviations uncertainty). However, Cs-137 was the only radionuclide reported in concentrations exceeding the de-selection criteria.
Cs-137 was identified in thirteen (13) of the fifteen (15) samples collected for non-parametric statistical testing.
Cs-137 was the primary radionuclide confirming the DQOs. The mean of the gamma spectroscopic analysis results for the sample population indicated that Cs-137 was present at levels lower than the concentrations of Cs-137 found in soil at off-site locations within the vicinity of the HNP as presented in the Health Physics TSD BCY-HP-0063.
A summary of the fifteen (15) samples collected for non-parametric statistical testing results is provided in Table 7.
ail7iuma oSoSampleesulsf W
tcaampe 1'opuiation-Samle urn~ej.~.~.K K
C-13 Fraction, of the 9530-0004-OOIF 1.41E-01 0.026 9530-0004-002F 2.76E-01 0.061 9530-0004-003F 2.12E-0 1 0.053 9530-0004-004F 2.97E-02 0.057 9530-0004-005F
.1.99E-0 1 0.091 9530-0004-006F
.7.96E-02 0.018 9530-0004-007F 3.53E-01 0.011 9530-0004-008F 1.44E-0l1 0.054 9530-0004-009F 1.36E-01 0.073 9530-0004-OIOF 6.45E-02 0.053 953 0-0004-01 IF 9.8 1E-02 0.042 9530-0004-012F 3.80E-02 0.059 9530-0004-013F 8.70E-02 0.042 9530-0004-014F 3.3 6E-0 1 0.022 9530-0004-015F 2.06E-02 0.030 (1) The Operational DCGL from Table 2 is 5.3 8 pCilg for Cs-13 7 to achieve 17 mrem/yr TEDE required by the sample plan.
The requested analyses included alpha spectroscopy, gas proportional counting, and liquid scintillation depending on the radionuclide and the measurement method.
All analyses met the required
ýMDC.
Revision 0 14 Revision 0 14
CENTRAL PENINSULA SURVEY UNIT 9530-0004 RELEASE RECORD As previously stated in Section 4 of this report, the criteria for de-selection of a radionuclide is a concentration that is less than 5% of the Operational DCGL for individual radionuclides and less than 10% of the Operational DCGLs for aggregates.
None of the HTDs met the criteria for detection (i.e., a result greater than two standard deviations uncertainty).
Three (3) biased samples were collected at a location: selected by FSS Supervision based on professional judgment and observation.
Gamma spectroscopy analysis was performed by the off-site laboratory to the required MDC.
.-, T~~-ie8iJdgme 4.14idSipeýsiie.,
01W37W VK'K 6J"
~rcn of ýhe
~~eN me
~
pi/.2gj2-0""
OeaioinaI-DC GL it" 9530-0004-016F 3.80E-02 0.034 9530-0004-017F 6.55E-03 0.030 9530-0004-018F 3.61E-02 0.022 (1) The Operational DCGL from Table 2 is 5.38 pCi/g for Cs-137 to achieve 17 mrem/yr TEDE
.7.
QUALITY CONTROL The off-site laboratory processed the split samples and performed gamma spectroscopy analysis.
Ten percent (10%) of the samples were selected for analysis, which exceeds the 5% minimum required by the LTP. The data were, evaluated using USNRC acceptance criteria specified in Inspection Procedure 84750 as detailed in HNP Procedure RPM 5.1-24, "Split Sample Assessment for Final Status Survey." There was acceptable agreement between field split results for Cs-137 at location 9530-0004-009.
However, Cs-137 was not detected in sufficient quantities in the field split results at location 9530-0004-004 to evaluate in accordance with procedure. Evaluation using the reported results for K-40 resulted in acceptable agreement between the field split results at location 9530-0004-004.
The sample analysis vendor, General Engineering Laboratories, LLC, maintains quality control and quality assurance plans as part of normal operation. Refer to for data and data quality analysis results.
- 8.
INVESTIGATIONS AND RESULTS Seven confirmatory samples were collected from scan area 1 and scan area 2 at locations exhibiting elevated scan readings. The samples are denoted as shown in Table 6, with the sample results shown in Table 9 below.
Revision 0 15 Revision 0 15
CENTRAL PENINSULA SURVEY UNIT 9530-0004 RELEASE RECORD
~
.~,. ~,.~abl~9.~Coifiratoiv~--Rl r
9530-0004-019F 9.65E-02 0.040 9530-0004-020F
-7.36E-03 0.023 9530-0004-021F 7.36E-03 0.032 9530-0004-022F 5.22E-02 0.029 9530-0004-023F 2.60E-02 0.024 9530-0004-024F 4.90E-02 0.030 9530-0004-025F 2.04E-02 0.023 (1) The Operational DCGL from Table 2 is 5.38 pCi/g for Cs-137 to achieve 17 mrem/yr TEDE
- 9.
REMEDIATION AND RESULTS Historically, no radiological remedial action as described by MARSSIM Section 5.4 was performed in this survey unit prior to or as a result of the FSS. Health Physics TSD BCY-HP-0078, "ALARA Evaluation of Soil Remediation in Support of Final Status Survey, " determined that remediation beyond that required to meet the release criteria is unnecessary and that the remaining residual radioactivity in soil was ALARA.
- 10.
CHANGES FROM THE FINAL STATUS SURVEY PLAN No changes were made to the FSS plan.
- 11.
DATA QUALITY ASSESSMENT (DQA)
The DQO sample design and data were reviewed in accordance with Procedure RPM 5.1-23, "Data Quality Assessment, " for completeness and consistency.
The sampling design had adequate power as indicated by the Retrospective Power Curve. The Sign Test was performed on the data and-compared to the original assumptions of the DQOs. The evaluation of the Sign Test results demonstrates that the survey unit passes the unrestricted release criteria, thus, the null hypothesis is rejected.
Documentation was complete and legible. Surveys and sample collection were consistent with the DQOs and were sufficient to ensure that the survey unit was properly designated as Class 3.
The preliminary data review consisted of calculating basic statistical quantities (e.g., mean, median, standard deviation). The mean and median values are well below the Operational DCGL. Also, the retrospective power curve shows that a sufficient number of samples were collected to achieve the desired power.
Therefore, the survey unit meets the unrestricted release criteria with adequate power as required by the DQOs.
Revision 0 16
CENTRAL PENINSULA SURVEY UNIT 9530-0004 RELEASE RECORD For Cs-137, the range of the data, about three (3) standard deviations, was not a particularly large variation considering that the levels were essentially at existing environmental levels where such variation is to be expected.
The difference between the mean and median was 10% of the standard deviation which indicates some skewness in the data.
The data was represented graphically through posting plots, a frequency plot, and a quantile plot. The frequency plot indicates positive skewness as confirmed by the calculated skew of 0.77.
All data, assessments, and graphical representations are provided in Attachment 4.
- 12.
ANOMALIES No anomalies were noted.
- 13.
CONCLUSION Survey Unit 9530-0004 has met the final DQOs of the FSS plan. The ALARA criteria for soils as specified in Chapter 4 of the LTP were achieved. Elevated Measurement Comparison and remediation was not required.
Cs-137 was used for statistical testing to determine the adequacy of the survey unit for FSS.
The sample data passed the Sign Test. The null hypothesis was rejected. The Retrospective Power Curve generated using COMPASS shows adequate power was achieved. The survey unit is properly designated as Class 3.
The dose contribution from soil is less than I mrem/yr TEDE based on the average concentration of the samples used for non-parametric statistical sampling.
This survey area is affected by existing groundwater (reference CY memo ISC 06-024); therefore the dose contribution from existing groundwater is bounded at two (2) mrem/yr TEDE.
This survey unit is not considered impacted by future groundwater radioactive contamination, as there are underground structures, systems or components containing residual radioactive material within the groundwater saturated zone in the area (reference CY memo ISC 06-024); therefore, the dose contribution from future groundwater is zero (0) mrem/yr TEDE.
The average total dose from residual radioactivity in this survey unit, including exposures from the three (3) components as described in Section 3, that is, residual radioactivity in soil, existing groundwater radioactivity, and future groundwater radioactivity from the burial of concrete foundations or footings from site buildings containing residual radioactivity, will not exceed 3 rnrem/yr TEDE.
Therefore, Survey Unit 9530-0004 is acceptable for unrestricted release.
Revision 0 17 Revision 0
'7
CENTRAL PENINSULA SURVEY UNIT 9530-0004 RELEASE RECORD
- 14.
ATTACHMENTS 14.1 Attachment 1 - Figures 14.2 Attachment 2 - Scan Results 14.3 Attachment 3 - Laboratory Results 14.4 Attachment 4 - DQA Results Revision I 18
CENTRAL PENINSULA SURVEY UNIT 9530-0004 RELEASE RECORD ATTACHMENT 1 (FIGURES)
j-CONN*E*CCUT RIVER*-
- \\
N Connecticut Yankee Atomic Power Company VSite Map With Reference To Survey Unit 9530-0004
I Legend IJ-<
= Wetland
= Not included in 9530-004
= Sample Point 0
I10 220 IFmt Connecticut Yankee Atomic Power Company Survey Unit 9530-0004 Final Status Survey Design
Legend
=Wetland Not included in 9530-004 0
.110 220 Feet Notes Reported Concentrations in pCi/g Connecticut Yankee Atomic Power Company Survey Unit 9530-0004 Final Status Survey Cs-137 Posting Plot
Legend
=Wetland 9530-004 S=Scan Area 0
I0 220Fo Notes Background ranged 5.om 6.1 kcpm to Scan8.4 kcmas Areadetermined by an E -600 with SPA-3 2
Probe
/
Refer to Table 6 for scan area results Fiue4Connecticut Yankee Atomic Power Company DaeBy Fi~ur '~
.Survey Unit 9530-0004 Final Status Survey Scan Areas
Legend Wetland
= Not included in 9530-004 1
- Scan Area
= Sample Point 110 220 IFeet Notes Refer to Table 8 for biased sample results Refer to Table 9 for confirmatory sample results Connecticut Yankee Atomic Power Company Survey Unit 9530-0004 Final Status Survey Biased and Confirmatory Samples
CENTRAL PENINSULA SURVEY UNIT 9530-0004 RELEASE RECORD ATTACHMENT 2 (SCAN RESULTS)
Survey Release Record Sample Location Scan Results Survey Unit 9530-0004 Sample Name 9530-04-SL-00-01-0 9530-04-SL-00-02-0 9530-04-SL-00-03-0 9530-04-SL-00-04-0 9530-04-SL-00-05-0 9530-04-SL-00-06-0 9530-04-SL-00-07-0 9530-04-SL-00-08-0 9530-04-SL-00-09-0 9530-04-SL-00-10-0 9530-04-SL-00-1 1-0 9530-04-SL-00-12-0 9530-04-SL-00-13-0 9530-04-SL-00-14-0 9530-04-SL-00-15-0 9530-04-SL-00-16-0 9530-04-SL-00-1 7-0 9530-04-SL-00-18-0 9530-04-SL-00-19-0
Background
(CPm) 7.15E+03 7.61 E+03 7.92E+03 6.47E+03 6.86E+03 6.33E+03 6.70E+03 7.70E+03 7.01E+03 6.25E+03 8.16E+03 7.33E+03 6.12E+03 5.85E+03 6.34E+03 6.79E+03 7.06E+03 7.94E+03 5.46E+03 Action Level (8.3E+0 8.36E+03 8.86E+03 9.19E+03 7.62E+03 8.04E+03 7.47E+03 7.87E+03 8.95E+03 8.21E+03 7.38E+03 9.45E+03 8.55E+03 7.24E+03 6.94E+03 7.48E+03 7.97E+03 8.26E+03 9.21 E+03 6.52E+03 Results Above Log Date LoQ Time E600 SIN Probe SIN (CPM) 8.39E+03 6.70E+03 7.84E+03 6.60E+03 6.58E+03 7.26E+03 6.37E+03 7.24E+03 7.54E+03 6.92E+03 6.97E+03 8.09E+03 6.92E+03 6.46E+03 5.59E+03 7.38E+03 7.78E+03 8.23E+03 6.32E+03 AL
-+
8/25/2006 8/25/2006 8/28/2006 8/25/2006 8/28/2006 8/24/2006 8/28/2006 8/28/2006 8/25/2006 8/25/2006 8/24/2006 8/25/2006 8/25/2006 8/24/2006 8/25/2006 8/24/2006 8/24/2006 8/24/2006 8/25/2006 9:52:00 10:22:00 9:50:00 8:22:00 10:21:00 14:35:00 10:11:00 9:47:00 8:35:00 10:35:00 14:42:00 10:50:00 9:43:00 14:24:00 10:12:00 14:05:00 13:52:00 14:15:00 10:00:00 1107 1107 1117 1107 1117 1114 1117 1117 1107 1107 1114 1107 1107 1114 1107 1114 1114 1114 1107 1013 1013 1001 1013 1001 1014 1001 1001 1013 1013 1014 1013 1013 1014 1013 1014 1014 1014 1013 AL - Action Level
Survey Release Record Scan Area Results Survey Unit 9530-0004 9530-0004 SCAN AREA 1 Sample Name 9530-04-SC-01-01-0 9530-04-SC-01 0 9530-04-SC-01-03-0 9530-04-SC-01-04-0 9530-04-SC-01-05-0 9530-04-SC-01-06-0 9530-04-SC-01-07-0 9530-04-SC-01-08-0 9530-04-SC-01-09-0 9530-04-SC-01-10-0 9530-04-SC-01-11 -0 9530-04-SC-01-12-0 9530-04-SC-01-13-0 9530-04-SC-01-14-0 9530-04-SC-01-15-0 9530-04-SC-01-16-0 9530-04-ER-01-16-1 9530-04-SC-01-17-0 9530-04-ER-01-17-1 9530-04-SC-01-18-0 9530-04-SC-01-19-0 9530-04-SC-01-20-0
..9530-04-SC:0 1-21 9530-04-SC-01-22-0 9530-04-SC-01-23-0 9530-04-ER-01-23-1 9530-04-ER-01-23-2 9530-04-SC-01 0 9530-04-ER-01-24-1
Background
(CPM) 7.02E+03 7.29E+03 7.18E+03 6.87E+03 7.55E+03 7.11E+03 6.82E+03 7.95E+03 6.73E+03 7.79E+03 7.05E+03 7.11E+03 7.22E+03 7.50E+03 7.06E+03 7.23E+03 7.23E+03 7.38E+03 7.38E+03 7.45E+03 7.94E+03 7.62E+03
.6-58E--03 7.76E+03 7.91E+03 7.91 E+03 7.91 E+03 6.87E+03 6.87E+03 Action Level (cm) 8.22E+03 8.51 E+03 8.39E+03 8.05E+03 8.79E+03 8.31 E+03 8.O0E+03 9.22E+03 7.90E+03 9.05E+03 8.25E+03 8.31E+03 8.43E+03 8.74E+03 8.26E+03 8.44E+03 8.44E+03 8.61 E+03 8.61 E+03 8.68E+03 9.21 E+03 8.87E+03 7-74E403 9.02E+03 9.18E+03 9.18E+03 9.18E+03 8.05E+03 8.05E+03 Results Above Log Date Log Time E600 SIN Probe SIN Lc£
_l 6.42E+03 8.31 E+03 7.64E+03
.7.17E+03 7.10E+03 7.20E+03 6.95E+03 7.85E+03 7.54E+03 7.55E+03 6.71 E+03 7.35E+03 7.56E+03 8.05E+03 6.99E+03 6.70E+03 1.02E+04 6.55E+03 9.09E+03 8.01E+03 7.71E+03 8.61E+03 7.35E+03 7.19E+03 7.37E+03 1.03E+04 9.63E+03 7.55E+03 9.35E+03 AL 9/6/2006 9/6/2006 9/6/2006 9/6/2006 9/6/2006 9/6/2006 9/6/2006 9/6/2006 9/6/2006 9/6/2006 9/6/2006 9/6/2006 9/6/2006 9/6/2006 9/6/2006 9/6/2006
+
9/6/2006 9/6/2006
+
9/6/2006 9/6/2006 9/6/2006 9/6/2006 2...............
6 006 9/6/2006 9/6/2006
+
9/6/2006
+
9/6/2006 9/6/2006
+
9/6/2006 8:39:00 8:43:00 9:48:00 9:51:00 9:55:00 9:59:00 10:04:00 10:08:00 8:03:00 8:08:00 8:12:00 8:16:00 8:22:00 8:27:00 8:31:00 10:20:00 13:47:00 10:30:00 13:48:00 10:38:00 10:45:00 10:52:00 10:07:00 10:17:00 10:33:00 13:51:00 13:52:00 10:49:00 13:54:00 1114 1114 1114 1114 1114 1114 1114 1114 1114 1114 1114 1114 1114 1114 1114 1114 1114 1114 1114 1114 1114 1114 11V1 1117 1117 1114 1114 1117 1114 1014 1014 1014 1014 1014 1014 1014 1014 1014 1014 1014 1014 1014 1014 1014 1014 1014 1014 1014 1014 1014 1014 1008 1008 1014 1014 1008 1014 AL - Action Level
Survey Release Record Scan Area Results Survey Unit 9530-0004 9530-04-SC-01-25-0 9530-04-SC-01-26-0 9530-04-ER-01-26-1 9530-04-SC-01-27-0 7.32E+03 6.90E+03 6.90E+03 8.44E+03 8.54E+03 8.09E+03 8.09E+03 9.75E+03 6.91 E+03 6.13E+03 9.03E+03 6.69E+03 9/6/2006 9/6/2006
+
9/6/2006 9/6/2006 11:00:00 11:10:00 13:56:00 11:15:00 1117 1117 1114 1117 1008 1008 1014 1008 9530-0004 SCAN AREA 2.:
Sample Name 9530-04-SC-02-01 -0 9530-04-SC-02-02-0 9530-04-SC-02-03-0 9530-04-SC-02-04-0 9530-04-SC-02-05-0 9530-04-SC-02-06-0 9530-04-SC-02-07-0 9530-04-SC-02-08-0 9530-04-SC-02-09-0 9530-04-SC-02-1 0-0 9530-04-SC-02-1 1-0 9530-04-SC-02-12-0 9530-04-SC-02-13-0 9530-04-SC-02-14-0 9530-04-SC-02-1 5-0 9530-04-SC-02-16-0 9530-04-SC-02-17-0
_9530M04-SC-0218-0-.
9530-04-SC-02-19-0 9530-04-SC-02-20-0 9530-04-SC-02-21-0 9530-04-SC-02-22-0 9530-04-SC-02-23-0 9530-04-SC-02-24-0
Background
(CPM) 6.39E+03 7.55E+03 6.99E+03 6.43E+03 7.11E+03 8.24E+03 6.60E+03 8.03E+03 7.55E+03 7.98E+03 6.62E+03 7.37E+03 6.96E+03 6.78E+03 6.49E+03 7.02E+03 7.57E+03
-6.93E+03--
8.12E+03 7.82E+03 7.86E+03 8.44E+03 6.76E+03 7.41 E+03 Action Level (CDM) 7.53E+03 8.79E+03 8.18E+03 7.58E+03 8.31 E+03 9.54E+03 7.76E+03 9.31 E+03 8.79E+03 9.26E+03 7.78E+03 8.60E+03 8.15E+03 7.96E+03 7.64E+03 8.22E+03 8.81E+03
8-.12E+03--
9.41E+03 9.08E+03 9.13E+03 9.75E+03 7.93E+03 8.64E+03 Results 7.20E+03 6.76E+03 6.21 E+03 5.92E+03 8.42E+03 6.78E+03 7.31 E+03 7.88E+03 7.01E+03 6.79E+03 7.51 E+03 6.11E+03 7.22E+03 7.21E+03 7.36E+03 6.22E+03 7.38E+03 1-E+03-7.72E+03 7.54E+03 6.92E+03 7.75E+03 7.05E+03 6.77E+03 Ablove Lop Date 8L 8/24/2006 8/24/2006 8/24/2006 8/24/2006 8/24/2006 8/24/2006
.8/24/2006 8/24/2006 8/24/2006 8/24/2006 8/24/2006 8/24/2006 8/24/2006 8/24/2006 8/24/2006 812412006 8/24/2006 8/24/2006 8/24/2006 8/24/2006 8/24/2006 8/24/2006 8/24/2006 8/24/2006 Log Time 10:59:00 11:01.00 11:06:00 11:09:00 11:17:00 11:14:00 11:12:00 11:08:00 11:04:00 11:01:00 9:44:00 9:48:00 9:54:00 10:01:00 10:07:00 10:13:00 10:20:00 10:27:00 10:32:00 10:39:00 10:35:00 10:29:00 10:23:00 10:16:00 E600 SIN 1117 1117 1117 1117 1114 1114 1114 1114 1114 1114 1114 1114 1114 1114 1114 1114 1114 1114 1114 1114 1117 1117 1117 1117 Probe SIN 1001 1001 1001 1001 1014 1014 1014 1014 1014 1014 1014 1014 1014 1014 1014 1014 1014 1014 1014 1014 1001 1001 1001 1001 AL - Action Level
9530-04-SC-02-25-0 9530-04-SC-02-26-0 9530-04-SC-02-27-0 9530-04-SC-02-28-0 9530-04-SC-02-29-0 9530-04-SC-02-30-0 7.
7.
7.
7.
6.
6.
Survey Release Record Scan Area Results Survey Unit 9530-0004 95E+03 9.22E+03 7.01E+03 8/24/2006 10:08:00 76E+03 9.02E+03 6.81E+03 8/24/2006 10:02:00 79E+03 9.05E+03 7.46E+03 8/24/2006 9:56:00 50E+03 8.74E+03 6.83E+03 8/24/2006 9:50:00 96E+03 8.15E+03 7.81 E+03 8/24/2006 9:46:00 nOr-Wn,
-7 1 C +-n.-
a '),---,-n) 8/24/2006 9:40.00 1117 1117 1117 1117 1117 1117 1001 1001 1001 1001 1001 1001 UU*TU*
I. I ;;:TL] UtJ U.-.**
=
U..)
AL - Action Level
CENTRAL PENINSULA SURVEY UNIT 9530-0004 RELEASE RECORD ATTACHMENT 3 (LABORATORY DATA)
General Narrative 1
CASE NARRATIVE For CONNECTICUT YANKEE
. RE: Soil PO# 002332 Work Order: 171454 SDG: MSR#06-1236 September 21, 2006 Laboratory Identification:
General Engineering Laboratories, LLC Mailing Address:
P.O. Box 30712 Charleston, South Carolina 29417 Express Mail Delivery and Shipping Address:
2040 Savage Road Charleston, South Carolina 29407 Telephone Number:
(843) 556-8171 Summary:
Sample receipt The sample(s) for this Project arrived at General Engineering Laboratories, LLC, (GEL) in Charleston, South Carolina on September 12, 2006. All sample containers arrived without any visible signs of tampering or breakage. The chain of custody contained the proper documentation and signatures. Upon receipt, the collect date and time for Sample 9530-0004-006F was noted as being incorrect on the COC. Jack McCarthy confirmed via email that the container information was correct.
The laboratory received the following sample(s):
Sample ID Client Sample ID 4-7-1454001-
-- -9530-0004-006F -- ---..
171454002 9530-0004-01IF 171454003 9530-0004-014F 171454004 9530-0004-016F 171454005 9530-0004-017F 171454006 9530-0004-018F 171454007 9530-0004-004F GENERAL ENGINEERING LABORATORIES, LLC a Member of THE GEL GROUP, INC.
PO. Box 30712 ° Charleston, SC 29417 ° 2040 Savage Road (29407)
Phone (843) 556-8171 - Fax (843) 766-1178
- www.gel.com
171454008 171454009 171454010 171454011 171454012 171454013 171454014 171454015 171454016 171454017 171454018 171454019 171454020 171454021 171454022 171454023 171454024 171454025 171454026 171454027 9530-0004-004FS 9530-0004-009F 9530-0004-009FS 9530-0004-013F 9530-0004-00IF 9530-0004-019F 9530-0004-015F 9530-0004-002F 9530-0004-OIOF 9530-0004-008F 9530-0004-007F 9530-0004-005F 9530-0004-020F 9530-0004-021F 9530-0004-022F 9530-0004-023F 9530-0004-024F 9530-0004-025F 9530-0004-012F 9530-0004-003F Items of Note:
There are no items of note.
Case Narrative:
Sample analyses were conducted using methodology as outlined in General Engineering Laboratories (GEL) Standard Operating Procedures. Any technical or.administrative problems during analysis, data review, and reduction are listed below by analytical parameter.
Analytical Request:
Twenty-five soil samples were analyzed for FSSGAM.
Two soil samples were analyzed for FSSALL.
Internal Chain-of-Custod-v:
Custody was maintained for the sample(s).
GENERAL ENGINEERING LABORATORIES, LLC a Member of THE GEL GROUP, INC.
PO. Box 30712 - Charleston, SC 29417 ° 2040 Savage Road (29407)
Phone (843) 556-8171 - Fax (843) 766-1178 ° www.gel.com
Data Package:
The enclosed data package contains the following sections: Case Narrative, Chain of Custody and Supporting Documentation and all analytical fractions.
I certify that this data package is in compliance with the SOW, both technically and for completeness, for other than the conditions detailed above. Release of the data contained in this hard copy data package has been authorized by the Laboratory Manager or a designee, as verified by the following signature.
Cheryl Jones Project Manager GENERAL ENGINEERING LABORATORIES, LLC a Member of THE GEL GROUP, INC.
RO. Box 30712 - Charleston, SC 29417 - 2040 Savage Road (29407)
Phone (843) 556-8171 - Fax (84) 766-1178
- www.gel.com
List of current GEL Certifications as of 21 September 2006 I.
I.--- - -V' I..
I..
'CLIA California Colorado Connecticut
- -Dept. of Navy EPA FloridaINELAP
-. Georgia_....
- " idan-a Kansas
- Kentucky Louisiana Maryland Massachusetts Michigan Nevada New Jersey New Mexico E87156 _
E87156 (FL/NELAP)
.N/A 200029 C-SC-01 E-10332.
I 90129 03046
- M -S C O I 2...
9903 SC02 SCO02 FL NELA EI56.
11501 9904 68-00485 10120001/10585001/10120002 02934 TX213-2006A TI04704235-06-TX S-52597 5
Chain of Custody And Supporting Documentation 6
Health Physics Procedure GPP-GGGR-R5104-003 -Attachment B-CY-001 Major Conn tYan e, Atomic Power Company Chain of Custody Form No. 2006-00521 ConnecticutYakeAoiPo rCmpn 362 Injun Hollow Road, East Hampton, CT 06424
`860-267-2556 Project Name: Haddam Neck Decommissioning Analyses Requested Lab Use Only Contact Name & Phone:
Comments:
Jack McCarthy 860-267-3924.
Analytical Lab (Name, City, State)
General Engineering Laboratories 2040 Savage Road. Charleston SC. 29407 843 556 8171. Attn. Cheryl Jones coo Priority: [] 30 D. Z 14 D. L 7D.[] 3 D.
C 1,
Sample Size-Sample Designation Date Time Media Type
&Type Comment, Preservation Lab Sample ID Code Code Code 9530-0004-006F 8/24/06 1440 TS G
BP X
9530-0004-01IF 8/24/06 1448 TS G
BP X
9530-0004-014F 8/24/06 1422 TS G
BP X
9530-0004-016F 8/24/06 1404 TS G
BP X
9530-0004-017F 8/24/06 1348 TS G
BP X
9530-0004-018F 8/24/06 1414 TS G
BP X
ET NOTES: PO #: 002332 MSR #: 06-1ZJ$ SSWP# NA Z LTP QA
[
Radwaste QA E
Non QA Samples Shipped Via:
Internal Container Z
Fed Ex Temp.: *,
Deg.
I up US C
El Hand Custody Sealed?
YOl NO
- 1) Relinquish Date/Time
- 2) Received By ^
Date/Time Custody Seal
(
( tOa 44Z 1)n'1' 9' -30
-]Other Intact?
- 3) Relinquished&by I
Date/Time
- 4) Req9eived By Date/Time YO NO Bill of Lading #
- 5) Relinquished By i
Date/Time
- 6) Received By Date/Time
Health Physics Procedure GPP-GGGR-R5104-003 -Attachment B-CY-001I Major Health Physics Procedure GPP-GGGR-R5 104-003 -Attachment B-CY-00 1 Major Chain of Custody Form No. 2006-00522 Connecticut Yankee Atomic Power Company 362 Injun Holloxw Road, East Hampton, CT 06424
'860-267-2556 Project Name: Haddam Neck Decommissioning Analyses Requested Lab Use Only Contact Name & Phone:
Comments:
Jack McCarthy 860-267-3924z Analytical Lab (Name, City, State)
General Engineering Laboratories 2040 Savage Road. Charleston SC. 29407--
I 843 556 8171. Attn. Cheryl Jones COOr Priority: E7 30 D. Z 14 D. El 17 D. l 3 D.
ii
~Container Sample Size-Sample Designation Date Time Media Type
&Type Comment, Preservation Lab Sample ID Code Code Code 9530-0004-004F 8/25/06 0823 TS G
BP X
9530-0004-004FS 8/25/06 0823 TS G
BP X
9530-0004-009F 8/25/06 0835 TS G
BP X
9530-0004-009FS 8/25/06 0835 TS G
BP X
9530-0004-013F 8/25/06 0950 TS G
BP X
9530-0004-001F 8/25/06 0952 TS G
BP X
9530-0004-019F 8/25/06 1003 TS G
BP X
9530-0004-015F 8/25/06 1013 TS G
BP X
9530-0004-002F 8/25/06 1023 TS G
BP X
9530-0004-OIOF 8/25/06 1037 TS G
BP X
9530-0004-012F 8/25/06 1058 TS G
BP X
MSR #: 06-/2't NOTES: PO #: 002332 SSWP# NA Z LTP QA El Radwaste QA El Non QA Samples Shipped Via:
0 Fed Ex E-ups El Hand D Other Bill of Lading #
Internal Container Temp.: IL Deg.
C Custody Sealed?
YO NO Custody Seal Intact?
YO NO
- 1) Relinquished B y/,
Date/Time
- 2) Rýeived ByI 1/
Date/Time
- 3) Relinquish4By " '
Date/Time 4). lceived By Date/Time
Health Physics Procedure.
GPP-GGGR-R5104-003-Attachment B-CY-001 Major Chain of Custody Form No. 2006-00523 Connecticut Yankee Atomic Power Company 362 Injun Holloxý Road, East Hampton, CT 06424 1860-267-2556 Project Name: Haddam Neck Decommissioning Analyses Requested Lab Use Only Contact Name & Phone:
I Comments:
Jack McCarthy 860-267-3924 Analytical Lab (Name, City, State)
General Engineering Laboratories 2040 Savage Road. Charleston SC. 29407 843 556 8171. Attn. Cheryl Jones Priority: El 30 D. Z 14 D. E-1:17 D. [
3 D.
Container Sample Size-Sample Designation Date Time Media Type
&Type Comment, Preservation Lab Sample ID Code Code Code 9530-0004-008F 8/28/06 0946 TS G
BP X
9530-0004-003F 8/28/06 0955 TS G
BP X
9530-0004-007F 8/28/06 1012 TS G
BP X
9530-0004-005F 8/28/06 1020 TS G
BP X
[
NOTES: PO #: 002332 MSR #: 06-12S6 SSWP# NA Z LTP QA El Radwaste QA E] Non QA Samples Shipped Via:
Z Fed Ex El ups El Hand El Other Bill of Lading#
Internal Cozitainer Temp.: ?I Deg.
C Custody Sealed?
YE NO Custody Seal Intact?
YE NO
- 1) Relinqui Date/Time
- 2) ce dBVp Date/Time
- 3) Relinquishek/By Date/Time
- 4) #eceived By Date/Time
Health Physics Procedurei,ý GPP-GGGR-R5104-003-Attachment B-CY-001 Major Chain of Custody Form Connecticut Yankee Atomic Power Company No. 2006-00535 362 Injun Hollow Road, East Hampton, CT 06424 860-267-2556 Project Name: Haddam Neck Decommissioning Analyses Requested Lab Use Only Contact Name & Phone:
i Comments:
Jack McCarthy 860-267-3924 Analytical Lab (Name, City, State)
General Engineering Laboratories
ý4 2040 Savage Road. Charleston SC. 29407 843 556 8171. Attn. Cheryl Jones Priority: D 30 D. Z 14 D. G 7 D. [] 3 D.
Container Sample Size-Sample Designation Date Time Media Type
&Type Comment, Preservation Lab Sample ID Code Code Code 9530-0004-020F 9/6/06 1350 TS G
BP X
9530-0004-021F 9/6/06 1355 TS G
BP X
9530-0004-022F 9/6/06 1400 TS G
BP X
9530-0004-023F 9/6/06 1402 TS G
BP X
9530-0004-024F 9/6/06 1407 TS G
BP X
9530-0004-025F 9/6./06 1410 TS G
BP X
5 NOTES: PO #: 002332 MSR #: 06-17--3*
[] Radwaste QA
[I Non QA
- 1) Relinquished By Date/Time
- 2) R ceived Date/Time
- 3) Relinquise"d B'y Date/Time
- 4) Pceived By Date/Time Samples Shipped Via:
0 Fed Ex El UPs
[] Hand l
- ffher Bill of Lading #
Internal Container Temp.: Z1 Deg.
C Custody Sealed?
YO NO Custody Seal Intact?
YO NO
Connecticut Yankee Statement of Work for Analytical Lab Services CY-ISC-SOW-O01 Figure 1. Sample Check-in List.
Date/Time Received.: -
/.
2 0
SDG#:
0s~c~
AA-(LoLG 12Z Work Order Number:
I14-W 5
J Li
[S A
Shipping Cdntainer ID: *
'*_e__ 4.
Chain of Custody#
J-"
1.-
Custody Seals-of shipping container intact?..
-Yes t No [ ]A) A
- 2.
Custody Seals dated and signed?.
Yes I No [ ]
- 3.
Chain-of-Custody record present?
Yes,,(
No[]
- 4.
Cooler temperature
, C o
- 5.
Vermiculite/packing materials is:
Wet [] Dry If
],
6:
Number of samples in shipping container:
"ee
- 7.
Sample holding times exceeded?
Yes [1 No IkJ
- 8. Samples have:
_-_-tape
-hazard labels
_..Xcustody seals x-- appropriate sample labels
- 9. Samples are.'
-i.-
in good condition
.leaking
-broken
.have air bubbles
- 10.
Were any anomalies identified in sample receipt?
Ye L No ]
- 11.
.Description of anomalies (include sample numbers):
A+
C Sample Custodian/Laboratory:
f Date:_____________'
Telephoned to:
On__
By iil
SAMPLE RECEIPT & REVIEW FORM 0
PM use only Client: CDA A LIe X SDG/ARCOC[Work Order:
5C- (7, t-qi-*I r
Date Received:
01
('u /
(A) Revie non-confor ng items are resolved prior to signing):
Received By:
ý-f
=
Sample Receipt Criteria Comments/Qualifiers (Required for Non-Confonnin ems)
Shipping containers received intact Circle Applicable: seals broken damaged container leaking con er otler (describe) and sealed?
7 Samples requiring cold Circle Coolant /
ice bags blue ice ic none other describe) 2 preservation within (4 +/- 2 C)?
Record preservation method.
Chain of custody documents included with shipment?
4 Sample containers intact and Circle Applicable:
damaged container leaking container other (describe) sealed?
I Samples requiring chemical Sample tl.
ainers affected and observed pH:
preservation at proper pH?
6 VOA vials free of headspace S pe I's and containers affected:
(defined as < 6mm bubble)?
Are Encore containers present?
7 (If yes, immediately deliver to VOAlaboratory_
Samples received within holdi Id's and tests affected:
time?
__iDs 9 Sample ID's on COC h ID's Sample ID's and containers affected:
on bottles?
__O___
10 Date & time o OC match date Sample ID's affected:
& time on ttles?
Numbe f containers received Sample In's affected:
matf number indicated on COC?
form is properly signed in 1 relinquished/received sections?
U5~
PC
-0 zoo(r,- Ooe,-z ý oorD2-2, (
OS7Z-1 00530e,O3O 4 Air Bill,Tracking #'s, &
-15j *t-41 Additional Comments ---,...
! "* ]*-
RSO RAD Receipt #
Suspected Hazard Information
- If > x2 area background is observed on samples identified as "non-
"Z"' &r o regulated/non-radioactive", contact the Radiation Safety group for further
- e Z
investigation.
- lRadiological Classification?
Z Maximum Counts Observed*:
0Qi)
B PCB Regulated?
/
Comments:
r
[Shipped as DUt) Hazardous C Material? If yes, contact Waste
/
UN#:Hazard Class Shipped; Manager or ESH Manager.
UN#:
PM (or PMA) review of Hazard classification:
Initials Date: 'AI2 f4 -
¥
SAMPLE RECEIPT & REVIEW FORM cJ
° CONTINUATION FORM Client:
Date Received:
-- k-ococ-ov.
4c CwM 1'r 21 7'lui5 U7w.Sggloo 7.oog-o 5,W bo6 -605;a9 "I
206 -0oo9s3e 2oo6-o"'S3,"
759~io ooi9 0o
-oo0 2,7 T-o4,c, I -*
44 P,,,st 1
?aa6-oo¶ I
&oc
..zzl(
~~~~~~-* <*r..:,+"-l\\
c-c; o.- - < -+
<{, 1,,
JA
RADIOLOG.ICAL ANALYSIS 14
Radiocheinistry Case Narrative Connecticut Yankee Atomic Power Co. (YANK)
Work Order 171454 Method/Analysis Information Product:
Alphaspec Am241, Cm, Solid ALL FSS Analytical Method:
DOE EML HASL-300, Am-05-RC Modified Prep Method:
Ash Soil Prep Dry Soil Prep GL-RAD-A-021 Method:
Dry Soil Prep Analytical Batch Number:
567824 Prep Batch Number:
567639 Dry Soil Prep GL-RAD-A-021 Batch Number:
567634 Sample ID Client ID 171454026 9530-0004-012F 171454027 9530-0004-003F 1201181597 Method Blank (MB) 1201181598 171450001(9520-04-1C) Sample Duplicate (DUP) 1201181599 171450001(9520-04-1C) Matrix Spike (MS) 1201181600 Laboratory Control Sample (LCS)
SOP Reference Procedure for preparation, analysis and reporting of analytical data are controlled by General Engineering Laboratories, LLC as Standard Operating Procedure (SOP). The data discussed in this narrative has been analyzed in accordance with GL-RAD-A-01 IREV# 14.
Calibration Information:
Calibration Information All initial and continuing calibration requirements have been met.
Standards Information Standard solution(s) for these analyses are NIST traceable and used before the expiration date(s).
Sample Geometry All counting sources were prepared in the same geometry as the calibration standards.
15
Quality Control (0C0 Information:
Blank Information The blank volume is representative of the sample volume in this batch.
Designated QC The following sample was used for QC: 171450001 (9520-04-1C).
QC Information All of the QC samples met the required acceptance limits.
Technical Information:
Holding Time All sample procedures for this sample set-were performed within the required holding time.
Preparation Information All preparation criteria have been met for these analyses.
Sample Re-prep/Re-analysis
- None of the samples in this sample set required reprep or reanalysis.
Miscellaneous Information:
NCR Documentation
'Nonconformance reports are generated to document any procedural anomalies that may deviate from referenced SOP or contractual documents. A nonconformance report (NCR) was not generated for this SDG.
Manual Integration No manual integrations were performed on data in this batch.
Additional Comments Additional comments were not required for this sample set.
Qualifier information Manual qualifiers were not required.
Method/Analysis Information 16
Product:
Analytical Method:
Alphaspec Pu, Solid-ALL FSS DOE EML HASL-300, Pu-11-RC Modified Ash Soil Prep Prep Method:
Dry Soil Prep GL-RAD-A-021 Method:
Analytical Batch Number:
Prep Batch Number:
Dry Soil Prep
- 567825 567639 Dry Soil Prep GL-RAD-A-021 Batch Number:
567634 Sample ID 171454026 171454027 1201181601 1201181602 1201181603 1201181604 Client ID 9530-0004-012F 9530-0004-003F Method Blank (MB) 171450001(9520-04-1C) Sample Duplicate (DUP) 171450001(9520-04-IC) Matrix Spike (MS)
Laboratory Control Sample (LCS)
SOP Reference Procedure for preparation, analysis and reporting of analytical data are controlled by General Engineering Laboratories, LLC as Standard Operating Procedure (SOP). The data discussed in this narrative has been analyzed in accordance with GL-RAD-A-01 I REV# 14.
- Calibration Information:
- Calibration Information All initial and continuing calibration requirements have been met.
Standards Information Standard solution(s) for these analyses are NIST traceable and used before the expiration date(s).
Sample Geometry All counting sources were prepared in the same geometry as the calibration standards.
Quality Control (QC) Information:
Blank Information The blank volume is representative of the sample volume in this batch.
Designated QC The following sample was used for QC: 171450001 (9520-04-iC).
QC Information All of the QC samples met the required acceptance limits.
17
Technical Information:
Holding Time All sample procedures for this sample set were performed within the required holding time.
Preparation Information All preparation criteria have been met for these analyses.
Sample Re-prep/Re-analysis None of the samples in this sample set required reprep or reanalysis.
Miscellaneous Information:
NCR Documentation Nonconformance reports are generated to document any procedural anomalies that may deviate from referenced SOP, or contractual documents. A nonconformance report (NCR) was not generated for this SDG.
Manual Integration No manual integrations were performed on data in this batch.
Additional Comments Additional comments were not required for this sample set.
Qualifier information Manual qualifiers were not required.
Method/Analysis Information Product:
Liquid Scint Pu241, Solid-ALL FSS Analytical Method:
DOE EML HASL-300, Pu-11-RC Modified Prep Method:
Ash Soil Prep Dry Soil Prep GL-RAD-A-021 Method:
Dry Soil Prep Analytical Batch Number:
567826 Prep Batch Number:
567639 Dry Soil Prep GL-RAD-A-021 Batch Number:
567634 18
Sample ID Client ID 171454026 9530-0004-012F 171454027 9530-0004-003F 1201181605 Method Blank (MB) 1201181606 171450001(9520-04-1C) Sample Duplicate (DUP) 1201181607 171450001(9520-04-1C) Matrix Spike (MS) 1201181608 Laboratory Control Sample (LCS)
SOP Reference Procedure for preparation, analysis and reporting of analytical data are controlled by General Engineering Laboratories, LLC as Standard Operating Procedure (SOP). The data discussed in this narrative has been anal;,zed in accordance with GL-RAD-A-035 REV# 8.
Calibration Information:
Calibration Information All initial and continuing calibration requirements have been met.
Standards Information Standard solution(s) for these analyses are NIST traceable and used before the expiration date(s).
Sample Geometry All counting sources were prepared in the same geometry as the calibration standards.
Quality Control (OC) Information:
Blank Information The blank volume is representative of the sample volume in this batch.
Designated QC The following sample was used for QC: 171450001 (9520-04-1C).
QC Information All of the QC samples met the required acceptance limits.
Technical Information:
Holding Time All sample procedures for this sample set were performed within the required holding time.
Preparation Information All preparation criteria have been met for these analyses.
Sample Re-prep/Re-analysis None of the samples in this sample set required reprep or reanalysis.
Miscellaneous Information:
NCR Documentation Nonconformance reports are generated to document any procedural anomalies that may deviate from 19
referenced SOP or contractual documents. A nonconformance report (NCR) was not generated for this SDG.
Manual Integration No manual integrations were performed on data in this batch.
Additional Comments Additional comments were not required for this sample set.
Qualifier information Manual qualifiers were not required.
Method/Analysis Information Product-Analytical Method:.
Prep Method:
Anialytical Batch Number:
Prep Batch Number:
Gamma,Solid-FSS GAM & ALL FSS 226 Ingrowth Waived EML HASL 300, 4.5.2.3 Dry Soil Prep 569467 567633 20
Sample ID.
Client ID 171454001 9530-0004-006F 171454002 9530-0004-01 IF
.171454003 9530-0004-014F 171454004 9530-0004-016F 171454005 9530-0004-017F 171454006 9530-0004-018F 171454007 9530-0004-004F 171454008 9530-0004-004FS 171454009 9530-0004-009F 171454010 9530-0004-009FS 171454011 9530-0004-013F
.171454012 9530-0004-OO1F
.171454013 9530-0004-019F 171454014 9530-0004-015F 171454015 9530-0004-002F 171454016 9530-0004-OIOF 171454017 9530-0004-008F 171454018 9530-0004-007F 171454019 9530-0004-005F 171454020 9530-0004-020F 1201185425 Method Blank (MB) 1201185426 171454001(9530-0004-006F) Sample Duplicate (DUP) 1201185427 Laboratory Control Sample (ICS)
SOP Reference Procedure for preparation, analysis and reporting of analytical data are controlled by General Engineering Laboratories, LLC as Standa+/-.'d Operating Procedure (SOP). The data discussed in this narrative has been analyzed in accordance with GL-RAD-A-013 REV# 12.
Calibration Information:
Calibration Information All initial and continuing calibration requirements have been met.
Standards Information Standard solution(s) for these analyses are NIST traceable and used before the expiration date(s).
.Sample Geometry All counting sources were prepared in the same geometry as the calibration standards.
Quality Control (OC) Information:
Blank Information
.............The-blank.-volume-is-representati~e_.Qothsanple volume in this batch._
Designated QC The following sample was used for QC: 171454001 (9530-0004-006F).
21
QC Information All of the QC samples met the required acceptance limits.
Technical Information:
Holding Time All sample procedures for this sample set were performed within the required holding time.
Preparation Information All preparation criteria have been met for these analyses.
Sample Re-prep/Re-analysis None of the samples in this sample set required reprep or reanalysis.
Miscellaneous Information:
'NCR Documentation Nonconformance reports are generated to document any procedural anomalies that may deviate from referenced SOP or contractual documents. The following NCR was generated for this SDG:
NCR 364074 was generated due to Failed RPD for DUP. 1. Samples 171454001 and 1201185426 did not meet the relative percent difference for K-40. 1. K-40 is a naturally occurring isotope. Reporting results.
Additional Comments Sample 1201185425 (MB) did not meet the relative percent difference requirement for Bi-212, however it does meet the relative error ratio requirement with value of 2.6.
Oualifier information Qualifier Reason UI U'
Data rejected due to high peak-width.
Data rejected due to interference.
Data rejected due to lowabundance.
. Analyte Cesium-134 Europium-155 Actinium-228
- Sample 171454002 171454001 171454020 171454005 Cesium-134 171454003 171454012 171454020
~.-Method/AnalyvsisInfort-nation.
22
Product:
Analytical Method:
Prep Method:
Analytical Batch Number:
Prep Batch Number:
Sample ID 171454021 171454022 171454023 171454024 171454025 171454026 171454027 1201185428 1201185429 1201185430 Gamnma,Solid-FSS.GAM & ALL FSS 226 Lngrowth Waived EML HASL 300, 4.5.2.3 Dry Soil Prep 569468 567634 Client ID 9530-0004-021F 9530-0004-022F 9530-0004-023F 9530-0004-024F 9530-0004-025F 9530-0004-012F 9530-0004-003F Method Blank (MB) 171454021(9530-0004-021F) Sample Duplicate (DUP)
Laboratory Control Sample (LCS)
SOP Reference Procedure for preparation, analysis and reporting of analytical data are controlled by General Engineering Laboratories, LLC as Standard Operating Procedure (SOP). The data discussed in this narrative has been analyzed in accordance with GL-RAD-A-013 REV# 12.
Calibration Information:
Calibration Information All initial and continuing calibration requirements have been met.
Standards Information Standard solution(s) for these analyses are NIST traceable and used before the expiration date(s).
Sample Geometry All counting sources were prepared in the same geometry as the calibration standards.
Quality Control (0C) Information:
Blank Information The blank volume is representative of the sample volume in this batch.
Designated QC The f6ll6,iiYn 5impie*l s
Wa**ised-f6 Q0C 17145402-1-(9530Z0004:02-1-F).
- QC Information All of the QC samples met the required acceptance limits.
23
Technical Information:
Holding Time All sample procedures for this sample set were performed within the required holding time.
Preparation Information All preparation criteria have been met for these analyses.
Sample Re-prep/Re-analysis Samples 171454022 (9530-0004-022F) and 171454024 (9530-0004-024F) were recounted due. to high MDAs.
Miscellaneous Information:
NCR Documentation Nonconformance reports are generated to document any procedural anomalies that may deviate from referenced SOP or contractual documents. A nonconformance report (NCR) was not generated for this SDG.
Additional Comments The sample and duplicate 1201185429 (9530-0004-021F) and 171454021 (9530-0004-021F) did not meet the relative percent difference requirement for Ac-228 and Cs-137, however they do mneet the relative error ratio requirement with a value of 2.03908 for Ac-228 and 0.2934 for Cs-137.
Oualifier information Qualifier Reason Analyte Sample UI Data rejected due to low abundance.
Cesium-134 171454024 171454027 Method/Analysis Information Product:
GFPC, Sr90, solid-ALL FSS Analytical Method:
EPA 905.0 Modified Prep Method:
Dry Soil Prep GL-RAD-A-021 Method:
Analytical Batch Number:
-Pr-*Bmeh-fNurber:
Ash Soil Prep Dry Soil Prep 567998
-567639------
Dry Soil Prep GL-RAD-A-021 Batch Number:
567634 24
Sample ID Client ID 171454026 9530-0004-012F 171454027 9530-0004-003F 1201181989 Method Blank (MB) 1201181990 171450001(9520-04-IC) Sample Duplicate (DUP) 1201181991 171450001(9520-04-IC) Matrix Spike PAS) 1201181992 Laboratory Control Sample (LCS)
SOP Reference Procedure for preparatiofi, analysis and reporting of analytical.dataare controlled by General Engineering Laboratories, LLC as Standard Operating Procedure (SOP). The data discussed in this narrative has been analyzed in accordance with GL-RAD-A-004 REV# 10.
Calibration Information:
Calibration Information All initial and continuing calibration requirements have been met.
Standards Information Standard solution(s) for these analyses are NIST traceable and used before the expiration date(s).
Sample Geometry All counting sources were prepared in the same geometry as the calibration standards.
Quality Control (QC) Information:
Blank Information The blank volume is representative of the sample volume in this batch.
Designated QC The following sample was used for QC: 171450001 (9520-04-1C).
QC Information All of the QC samples met the required acceptance limits.
Technical Information:
Holding Time All sample procedures for this sample set were performed within the required holding time.
Preparation Information All preparation criteria have been met for these analyses.
Saimple-Re-prep/Re-analysis----------
None of the:samples in this sample set required reprep or reanalysis.
Chemical Recoveries All chemical recoveries meet the required acceptance limits for this sample set.
25
Miscellaneous Information:
NCR Documentation Nonconformance reports are generated to document any procedural anomalies that may deviate from referenced SOP or contractual documents. A nonconformance report (NCR) was not generated for this SDG.
Additional Comments Additional comments were not required for this sample set.
Oualifier information Manual qualifiers were not required.
Method/Analysis Information Product:
Liquid Scint Tc99, Solid-ALL FSS Analytical Method:
Analytical Batch Number:
Sample ID 171454026 171454027 1201181858 1201181859
- 1201181860 1201181861 DOE EML HASL-300, Tc-02-RC Modified 567935 Client ID 9530-0004-012F 9530-0004-003F Method Blank (MB) 171454026(9530-0004-012F) Sample Duplicate (DUP) 171454026(9530-0004-012F) Matrix Spike (MS)
Laboratory Control Sample (LCS)
SOP Reference Procedure for preparation, analysis and reporting of analytical data are controlled by General Engineering Laboratories, LLC as Standard Operating Procedure (SOP). The data discussed in this narrative has been analyzed in accordance with GL-RAD-A-005 REV# 13.
Calibration Information:
Calibration Information All initial and continuing calibration requirementshave been met.
Standards Information Standard solution(s) for these analyses are NIST traceable and used before' the expiration date(s).
Sample Geometry All counting sources were prepared in the same geometry as the calibration standards.
26
Quality Control (QC) Information:
Blank Information The blank volume is representative of the sample volumes in this batch.
Designated QC The following sample was used for QC: 171454026 (9530-0004-012F).
QC Information All of the QC samples met the required acceptance limits.
Technical Information:
Holding Time All sample procedures for this sample set were performed within the required holding time.
Preparation Information All preparation criteria have been met for these analyses.
Sample Re-prep/Re-analysis Samples were recounted due to high MDAs.
Miscellaneous Information:
NCR Documentation Nonconformance reports are generated to document any procedural anomalies that may deviate from referenced SOP or contractual documents. A nonconformance report (NCR) was not geinerated for this SDG.
Additional Comments Additional comments were not required for this sample set.
Qualifier information Manual qualifiers were not required.
Method/Analysis Information Product:
Liquid Scint FeSS, Solid-ALL FSS Analytical Method:
DOE RESL Fe-1, Modified Prep Method:
Ash Soil Prep Dry Soil Prep GL-RAD-A-021 Method:
Dry Soil Prep Analytical Batch Number:
567933 Prep Batch Number:
567639 Dry Soil Prep GL-RAD-A-021 Batch Number:
567634 27
Sample ID Client ED 171454026 9530-0004-012F 171454027 9530-0004-003F 1201181849 Method Blank (MB) 1201181850 171450001(9520-04-iC) S.ample Duplicate (DUP) 1201181851 171450001(9520-04-1C) Matrix Spike (MS) 1201181852 Laboratory Control Sample (LCS)
SOP Reference Procedure for preparation, analysis and reporting of analytical data are controlled by General Engineering Laboratories, LLC as Standard Operating Procedure (SOP). The data discussed in this narrative has been analyzed in accordance with GL-RAD-A-040 REV# 3.
Calibration Infor.ation:
Calibration' Information All initial and continuing calibration requirements have been met.
Standards Information Standard solution(s) for these analyses are NIST traceable and used before the expiration date(s).
- Sample Geometry
- All counting sources were prepared in the same geometry as the calibration standards.
Quality Control (QC) Information:
Blank Information The blank volume is representative of the sample volume in this batch.
.Designated QC The following sample was used for QC: 171450001 (9520-04-1C).
QC Information All of the QC samples met the required acceptance limits.
Technical Information:
Holding Time All sample proceduresfor this sample set were performed within the required holding time.
Preparation Information All preparation criteria have been met for these analyses.
-Sample-Re-prep/Re-analysis------------
Samples 1201181849 (MB), 1201181850 (9520-04-IC), 1201181851 (9520-04-1C), 1201181852 (LCS), 171454026 (9530-0004-012F) and 171454027 (9530-0004-003F) were recounted due to the quench number being outside the calibration range.
28
Miscellaneous Information:
NCR Documentation Nonconformance reports are generated to document any procedural anomalies that may deviate from referenced SOP or contractual documents. A nonconformance report (NCR) was not generated for this SDG.
Additional Comments Additional comments were not required for this sample set.
Qualifier information Manual qualifiers were not required.
Method/Analysis Information Product:
Liquid Scint Ni63, Solid-ALL FSS Analytical Method:
DOE RESL Ni-I, Modified Prep Method:
Dry Soil Prep GL-RAD-A-021 Method:
Analytical Batch Number:
Prep Batch _Number:
Dry Soil Prep GL-RAD-A-021 Batch Number:
Ash Soil Prep Dry Soil Prep 567934 567639 567634 Sample ID 171454026 171454027 1201181854
.1201181855 1201181856 1201181857 Client !D 9530-0004-012F 9530-0004-003F Method Blank (MB) 171450001(9520-04-IC) Sample Duplicate (DUP) 171450001(9520-04-1 C) Matrix Spike (MS)
Laboratory Control Sample (LCS)
SOP Reference Procedure for preparation, analysis and reporting of analytical data are controlled by General Engineering Laboratories, LLC as Standard Operating Procedure (SOP). The data discussed in this narrative has been analyzed in accordance with GL-RAD-A-022 REV# 8.
Calibration Information:
Calibration Information All initial and continuing calibration requirements have been met.
29
.Standards Information Standard solution(s) for these analyses are NIST traceable and used before the expiration date(s).
Sample Geometry All counting sources were prepared in the same geometry as the calibration standards.
Quality Control (0C) Information:
Blank Information The blank voiume is representative of the sample volume in this batch.
Designated QC The following sample was used for QC: 171450001 (9520-04-iC).
QC Information All of the QC samples met the required acceptarce limits.
Technical Information:
Holding Time All sample procedures for this sample set were performed within the required holding time.
Preparation Information All preparation criteria have been met for these analyses.
Sample Re-prep/Re-analysis None of the samples in this sample set required reprep or reanalysis.
Miscellaneous Information:
NCR Documentation Nonconformance reports are generated to document any procedural anomalies that may deviate from referenced SOP or contractual documents. A nonconformance report (NCR) was not generated for this SDG.
Additional Comments Additional comments were not required for this sample set.
Qualifier information Manual qualifiers were not required.
Method/Analysis Information Product:
LSC, Tritium Dist, Solid-HTD2,ALL FSS Analytical Batch Number:
567994 30
Sample ID Client ID 171454026 9530-0004-012F 171454027 9530-0004-003F 1201181977 Method Blank (MB) 1201181978 171454026(9530-0004-012F) Sample Duplicate (DUP) 1201181979 171454026(9530-0004-012F) Matrix Spike (MS) 1201181980 Laboratory Control Sample (LCS)
SOP Reference Procedure forpreparation, analysis and reporting of analytical data are controlled by General Engineering Laboratories, LLC as Standard Operating Procedure (SOP). The data discussed in this narrative has been analyzed in accordance with GL-RAD-A-,002 REV# 13.
Calibration Information:
Calibration Information All initial anrd continuing calibration requirements have been met.
Standards Information Standard solution(s) for these analyses are NIST traceable and used before the expiration date(s).
Sample Geometry All counting sources were prepared in the same geometry as the calibration standards.
Quality Control (OC) Information:
Blank Information The blank volume is representative of the sample volumes in this batch.
Designated QC The following sample was used for QC: 171454026 (9530-0004-012F).
QC Information All of the QC samples met the required acceptance limits.
Technical Information:
Holding Time All sample procedures for this sample set were performed within the required holding time.
Preparation Information All preparation criteria have been met for these analyses.
-Sample-Re-prep/Re-analysis~......
Sample 171454027 (9530-0004-003F) was recounted due to the quench number beincoutsidt-lie calibration range.
31
Miscellaneous Information:
NCR Documentation Nonconformance reports are generated to document any procedural anomalies that may deviate from referenced SOP or contractual documents. The following NCR was generated for this SDG:
NCR 361821 was generated due to Container scanning event for custody missed. 1. The analyst did not scan the samples 171454026, 171454027, 171459018, and 171459019 into the batch prior to analysis, however the samples did remain in their custody at all times. 1. The error has been corrected and the analyst has been instructed on the proper scanning procedures.
Additional Comments Additional comments were not required for this sample set.
Oualifier information Manual qualifiers were not required.
Method/Analysis Information Product:
Liquid Scint C14, Solid AII,FSS Analytical Method:
Analytical Batch Number:
Sample EID 171454026
- 171454027 1201181862 120118.1863
- 1201181864 1201181865 EPA EERF C-01 Modified 567937 Client ID 9530-0004-012F 9530-0004-003F Method Blank (MB) 171454026(9530-0004-012F) Sample Duplicate (DUP) 171454026(9530-0004-012F) Matrix Spike (MS)
Laboratory Control Sample (LCS)
SOP Reference Procedure for preparation, analysis and reporting of analytical data are controlled by General Engineering Laboratories, LLC as Standard Operating Procedure (SOP). The data discussed in this narrative has been analyzed in accordance with GL-RAD-A-003 REV# 8.
Calibration Information:
Calibration Information All initial and continuing calibration requirements have been met.
Standards Information Standard solution(s) for these analyses are NIST traceable and used before the expiration date(s).
Sample Geometry 32
All. counting sources were prepared in the same geometry as the calibration standards.
Quality Control (0C) Information:
Blank Information The blank volume is representative of the sample volume in this batch.
Designated QC The following sample was used for QC: 171454026 (9530-0004-012F).
QC Information All of the QC samples met the required acceptance limits.
Technical Information:
Holding Time All sample procedures for this sample set were performed within the required holding time.
Preparation Information All preparation criteria have been met for these analyses.
Sample Re-prep/Re-analysis None of the. samples in this sample set required reprep or reanalysis.
Miscellaneous Information:
NCR Documentation Noriconfonnmance reports are generated to document any procedural anomalies that may deviate from referenced.SOP or contractual documents. A nonconformance report (NCR) was not generated for this
- SDG.
Additional Comments Additional comments were not required for tlhis sample set.
Oualifier information Manual qualifiers were not required.
Certification Statement Where the analytical method. has been performed under NELAP certification, the analysis has met all of the requirements of the NELAC standard unless otherwise noted in the analytical case narrative.
Review Validation:
_GEL.rqUijre s all analytical data to be verified by a qualified data validator. In addition, all data designated for CLP or CLP-like packaging will receive a th-irdlevel valid-ati-fipbiC6 15ti-a-of-the.
data package.
The following data validator verified the information presented in this case narrative:
33
9,f~
'n
.1 fn f e'
I 34
General Engineering Laboratories Form GEL-NCR Rev. 06/05 NCR Report No.:
361821 Revision No.:
COMPANY - WIDE NONCONFORMANCE REPORT Mo.Day Yr.
Division:
Quality Criteria:
Type:
21-SEP-06 Radiochemistry Specifications Process Instrument Type:
Test/ Method:
Matrix Type:
Client Code:
LSC EPA 906.0 Modified Solid YANK Batch ID:
Sample Numbers:
567994 See Below Potentially affected work order(s)(SDG): 171454(MSR#06-1236),171459(MSR#06-1237)
Application Issues:
Container scanning event for custody missed Specification and Requirements NRG Disposition:
Nonconformance
Description:
- 1. The analyst did not scan the samples 171454026, 171454027,
- 1. The error has been corrected and the analyst has been Instructed on the 171459018, and 171459019 intothe batch prior to analysis, however the proper scanning procedures.
samples did remain in their custody at all times.
Originator's Name:
Amy Scott Quality Review:
Data Validator/Group Leader:
Melanie Aycock 22-SEP-06 21 -SEP-06 Director:
Page 1 35
General Engineering Laboratories Form GEL-NCR Rev. 06/05 NCR Report No.:
364074 Revision No.:
COMPANY - WIDE NONCONFORMANCE REPORT Mo.Day Yr.
Division:
Quality Criteria:
Type:
26-SEP-06 Radiochemistry Specifications Process Instrument Type:
Test / Method:
Matrix Type:
Client Code:
GAMMA SPECTROMETER EML HASL 300, 4.5.2.3 Solid YANK Batch ID:
Sample Numbers:
569467 See Below Potentially affected work order(s)(SDG):171454(MSR#06-1236)
Application Issues:
Failed RPD for DUP Specification and Requirements NRG Disposition:
Nonconformance
Description:
- 1. Samples 171454001 and 1201185426 did not meet the relative
- 1. K-40 is a naturally occurring isotope. Reporting results.
percent difference for K-40.
Originator's Name:
Heather Anderson Quality Review:
Data Valldator/Group Leader:
26-SEP-06 Director:
Page 1 36
SAMPLE DATA
SUMMARY
37
GENERAL ENGINEERING LABORATORIESI LLC 2040 Savage Road Charleston SC 29407 - (843) 556-8171-www.gel.com Certificate of Analysis Report for YANK001 Connecticut Yankee Atomic Power Co.
Client SDG: MSR#06-1236 GEL Work Order: 171454.
The Qualifiers inthis report are defined as follows:
A quality control analyte recovery is outside of specified acceptance criteria Analyte is a surrogate compound U
Analyte was analyzed for, but not detected above the MDL, MDA, or LOD.
UI Gamma Spectroscopy--Uncertain identification ND The arnalyte concentration is not detected above the detection limit.
The above sample is reported on a dry weight basis except where prohibited by the analytical procedure.
Where the analytical method has been performed under NELAP certification, the analysis has met all of the requirements of the NELAC standard unless qualified on the Certificate of Analysis.
This data report has been prepared and reviewed in accordance with General Engineering Laboratories, LLC standard operating procedures. Please direct any questions to your Project Manager, Cheryl Jones.
Reviewed by 38
GENERAL ENGINEERING LABORATORIES, LLC 2040 Savage Road Charleston SC 29407 - (843) 556-8171 - www.gel.com Certificate of Analysis Company:
Comnecticut Yankee Atomic.Power Address:
362 Injtn Hollow Rd East Hampton, Connecticut 06424
Contact:
Mr. Jack McCarthy Project:
Soils PO# 002332 Report Date:
September 26, 2006 Ciient Sample ID:
9530-0004-006F Project:
YANK01204 Sample ID:
171454001 Client ID:
yApNK.001 Matrix:
TS Vol. Recv.:
Collect Date:
22-AUG-06 Receive Date:
12-SEP-06 Collector:
Client Moisture:
5.63%
Parameter Qualifier Result Uncertainty
.LC TPU MIA Units DF Analyst Date Time Batch Mt Rad Ganmna Spec Analysis Gaonma,Solid-FSS GAM & ALL FSS 226 Ingrowth Waived Actinium-228 0.490 Americium-241 U
0.112 Bismuth-212 U
0.163 Bisinuth-214 0.348 Cesium-134 U
0.0339 Cesium-137 0.0796 Cobalt-60 U
0.00766 Europium-152 U 0.000266 Europium-154 U
0.0642 Europium-155 Ul 0.00 Lead-212 0.465 Lead-214 0.417 Manganese-54 U
0.0199 Niobium-94 U
0.016 Potassium-40 9.54 Radium-226 0.348 Silver-108m U
-0.0181 Thallium-208
. 0.150
+/-0.141
+/-0.121
+/-0.172
+/-0.081
+/-0.017
+/-0.0245
+/-0.0254
+/-0.0528
+)-0.080
+/-0.100
+/-0.0565
+/-0.0853
+/-0.019
+/-0.0153
+/-0.855
+/-0.081 W/-0.0169
+/-0.0344 0.0556 0.0788 0.164 0.0327 0.0216 0.0159 0.020 0.046 0.0603 0.0485
.0.0242 0.0294 0.0178 0.0158 0.162 0.0327 0.0139 0.0204
+/-0.141
+/-0.121
+/-0.172
+/-0.081
+/-0.017
+/-0.0245
+/-0.0254
+/-0.0528
+/-0.080
+/-0.100
+/-0.0565
+/-0.0853
+/-0.019
+/-0.0153
+/-0.855
+/-0.081
+/-0.0169
+/-0.0344 0.125 0.166 0.354 0.0712 0.0473 0.0351 0.0454 0.0984 0.135 0.102 0.0515 0.0634 0.0393 0.0347 0.376 0.0712 0.0302 0.0438 pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g
- pCilg pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g MJHI 09/20/060720 569467 The following Prep Methods were performed Method Description Analyst Date Time Prep Batch Dry Soil Prep Dry Soil Prep GL-RAD-A-021 AXP2 09/12/06 1739 567633 The following Analytical Methods were performed Method Description EML HASL 300, 4.5.2.3 Notes:
The Qualifiers in this report are defined as follows A quality control analyte recovery is outside of specified acceptance criteria Result is less than value reported 39
GENERAL ENGINEERING LABORATORIES, LLC 2040 Savage Road Charleston SC 29407 -. (843) 556-8171 - www.gel.com Certificate of Analysis Company:
Connecticut Yankee Atomic Power Address:
362 Injun Hollow Rd E
"ast Hampton, Connecticut 06424 Report Date: September 26, 2006
Contact:
rh-.
Jack McCarLhy Project:
Soils PO# 002332 Client Sumple ID:
9530-0004-006F Project:
YANKO 1204 SamplelD:
171454001 ClientID:
YANK001 Vol. Recv.:
Parameter Qualifier Result Uncertainty LC TPU MDA Units DF Analyst Date Time Batch Mt Result is greater than value reported A
The TIC is a suspected aldol-condensation product B
Target analyte was detected in the associated blank-BD Results are either below the MDC or tracer recovery is low C
Analyte has been confirmed by GC/MS analysis D
Results are reported from a diluted aliquot of the sample H
Analytical holding time was exceeded J
Value is estimated N/A Spike recovery lihnits do not apply. Sample concentration exceeds spike concentration by 4X or more R
Sample results are rejected U
Analyte was analyzed for, but not detected above the MDL, MDA, or LOD.
U1 Gamma Spectroscopy--Uncertain identification X
Consult Case Narrative, Data Summary package, or Project Manager concerning this qualifier Y
QC Samples were not spiked with this compound A
RPD of sample and duplicate evaluated using +1-RL. Concentrations are <5X the RL h
Preparation or preservation holding time was exceeded The above sample is reported on a dry weight basis.
40
GENERAL ENGINEERING LABORATORIES, LLC 2040 Savage Road Charleston SC 29407 - (843) 556-8171 - www.gel~com Certificate of Analysis Company:
Connecticut Yankee Atomic Power Address:
.362 Injun Hollow Rd East Hampton, Connecticut 06424
Contact:
Mr. Jack'McCarthy Project:
Soils PO# 002332 Report Date: September 26, 2006.
Client Sample ID:
Sample ID:
Matrix:
Collect Date:
Receive Date:
Collector:
9530-0004-011F 171454002 TS 24-AUG-06 12-SEP-06 Client Project:
YANK01204 Client ID:
YANKOO Vol. Recv.:
loisture:
3.34%
Parameter Qualifier Result Uncertainty LC TPU MIDA Units DF Analyst Date Time Batch Mt Rad Gamna Spec Analysis Gainmn.Solid-FSS GAM & ALL FSS 226 Ingrowth Waived Actinium-228 0.610
+/-0.168 0.0674
+/-0.168 0.149 pCi/g MJH1 09/20106 0720 569467 Americium-241 U
0.0767
+1-0.0879 0.0853 +/-0.0879 0.178 pCi/g Bistnuth-212 U
0.349
+/-0.331 0,166
+/-0.331 0.360 pCi/g Bismuth-214
- 0.489
+/-0.0888 0.0386 +/-0.0888 0.0832.
pCi/g Cesium-134
- UI 0.00
+/-0.063 0.0221
+/-0.063 0.0483 pCi/g Cesium-137 0.0981
+/-0.0549 0.0213 +/-0.0549 0.046 pCi/g Cobalt-60 U
0,0248
+/-0.0237 0.0232 +/-0.0237 0.0519 pCilg Europium-152 U
-0.0292
+/-0.0702 0.0516 +/-0.0702 0.110 pCi/g Europium-154 U
0,0309
+/-0.0754 0.0678 +/-0.0754 0.150 pCi/g Europium-155 "U
-2.100E-
+/-0.0652 0.0585. +/-0.0652 0.122 pCi/g 05 Lead-212 0.682
+/-0.0757 0.0326 +/-0.0757 0.0683 pCi/g Lead-214 0.449
+/-0.0922 0.0394 +/-0.0922 0.0837 pCi/g.
Manganese-54 U -0.00136
+/-0.023 0.0195
+/-0.023 0.0427 pCi/g Niobium-94 U
0.00947
+/-0.0304 0.0209 +/-0.0304 0.0449 pCi/g Potassium-40
... 11.3
+/-1.02 0,151
+1-1.02 0.356 pCi/g Radium-226 0.489
+/-0.0888 0.0386 +/-0.0888 0.0832 pCi/g Silver-]08m U
-0.0129
+/-0.021 0.017
+/-0.021 0.0366 pCi/g Thallium-208 0.169
.+/-0.053 0.0169
+/-0.053 0.0371 pCi/g The following Prep Methods were performed Method Description Analyrt Date Time Prep Batch Dry Soil Prep Dry Soil Prep GL-RAD-A-021 AXP2 09/12/06 1739 567633 The following Analytical Methods were performed I
EML HASL 300, 4.5.2.3 Notes:
The Qualifiers in this report are defined as follows A quality control analyte recovery is outside of specified acceptance criteria Result is less thia value reported 41
GENERAL ENGINEERING LABORATORIES, LLC 2040 Savage Road Charleston SC 29407 - (843) 556-8171 - www.gel.com Certificate of Analysis Company Connecticut Yankee Atomic Power Address:
362 Injun Hollow Rd East Hampton, Connecticut 06424.
Report Date: September 26, 2006
Contact:
Mr. Jack McCarthy Project:
Soils PO# 002332 Client Sample ID:
9530-0004-01IF Project:
YANK01204 Sample ID:
- 171454002 Client ID:
YANK001.
Vol. Recv.:
Parameter Qualifier Result Uncertainty LC TPU MDA Units DF Analyst Date Time Batch Mt.
Result is greater than value reported A
The TIC is a suspected aldol--condensation product B
Target analyte was detected in the associated blank BD Results are either below the IMDC or tracer recovery is low C
Analyte has been confirmed by GC/MS analysis
- D Results are reported from a diluted aliquot of the sample H
Analytical holding time was exceeded Value is estimated N/A Spike recovery limits do not apply. Sample concentration exceeds spike concentration by 4X or more R
Sample results are rejected
- U
.:Analyte was analyzed for, but not detected above the MDL, lIDA, or LOD.
UI Gamma Spectroscopy--Uncertain identification X :Consult Case Narrative, Data Summary package, or Project Manager concerning this qualifier Y
QC Samples were not spiked with this compound A
RPD of sample and duplicate evaluated using +!-RL. Concentrations are <5X the RL h
Preparation or preservation holding time was exceeded The above sample is reported on a dry weight basis.
42
GENERAL ENGINEERING LABORATORIES, LLC 2040 Savage Road Charleston SC 29407 - (843) 556-8171 - www.gel.com Certificate of Analysis Company:
Connecticut Yankee Atomic Power Address 362 Injun Hollow Rd East Hapnpton, Connecticut 06424
Contact:
Mr. Jack McCarthy Project:
Soils PO# 002332 Report Date: September 26, 2006 Client Sample ID:
Sample lID:
Matrix::
Collect bate:
Receive Date:
Collector:
Moistu'ie:
9530-0004-014F 171454003 TS 24-AUG-06 12-SEP-06 Client 7.65%
Project:
YANK01204 Client ID:
YANK001 Vol. Recv.:
Parameter Qualifier Result Uncertainty LC TPU "I\\IDA Units DF Analyst Date Time Batch Mt Rad Gamma Spec Analysis Ganna, Solid-FSS GAVI1 & ALL FSS 226 Ingrowih.
Waived Actinium-228 0.647
+/-0.176 0.0821
+/-0.176 0.178 pCi/g MJH-1 09/26/06 0917 569467 Amcricium-241 U
0.0274
+/-0.115 0.0898
+/-0.115 0.187 pCi/g Bismuth-212 0.571
+1-0.285.
0.181
+/-0.285 0.389 pCi/g Bismuth-214 0.648
+/-0.116 0.0363
+/-0.116 0.0783 pCi/g Cesium-134 UT 0.00
+/-0.0444 0.0315 +/-0.0444 0.067 pCi/g Cesium-137 0.336
+/-0.0536 0.0209 +/-0.0536 0.0452 pCi/g Cobalt-60. "
U -0.00958
+/-0.0275 0.0223 +1-0.0275 0.050 pCi/g
.Europium-152 U
-0.0469
+/-0.0768 0.0617 +/-0.0768 0.130 pCi/g Europium-154 U
-0.0251
+/-0.0721 0.0585 +/-0.0721 0.132 pCi/g Europium-155 U
0.0421
+/-0.0645 0.0597 +/-0.0645 0.124 pCi/g Lead-212 0.754
+/-0.0813 0.0369 +/-0.0813 0.0768 pCi/g Lead-214 0.626
+/-0.0936 0.0448 +/-0.0936 0.0943 pCi/g
. Manganese-54 U
0.00646
+/-0.0273 0.0234 +/-0.0273 0.0506 pCi/g Niobium-94 U
0.00844
+/-0.0223 0.0197 +/-0.0223 0.0423
.pCi/g" Potassium-40 10.1
+/-1.07 0.179
+/-1.07 0.411 pCi/g Radium-226 0.648
+/-0.116 0.0363
+/-0.116 0.0783 pCi/g-
- Silver-108m U -0.00146
+/-0.0247 0.0202 +/-0.0247 0.0429 pCi/g Thallium-208 0.224
+/-0.0567 0.0241 +/-0.0567 0.0513 pCi/g The following Prep Methods were performed "Method Description Analyst Date Time Prep Batch Dry Soil Prep Dry Soil Prep GL-RAD-A-021 AXP2 09/12/06 1739 567633 The following Analytical Methods were performed 1
EML HASL 300, 4.5.2.3 Notes:
The Qualifiers in this report are defined as follows:
A quality control analyte recovery is outside of specified acceptance criteria Result is less than value reported 43
GENERAL ENGINEERING LABORATORIES, LLC 2040 Savage Road Charleston SC 29407 - (843) 556-8171 - www.Gel.com Certificate of Analysis Company:
Connecticut Yankee Atomic Power Address:
362 Injun Hollow Rd East Hampton, Connecticut 06424 Report.Date:
September 26, 2006
Contact:
Mi. Jack McCarthy Project:
Soils PO# 002332 Client Sample ID:
9530-0004-014F Project:
YANK01204 Sample lni:
.171454003 ClientYID:
yANKtr" PretrQae.
i s De Parameter Qualifie JaekMc ulth Unetit LC
- P.D unt "F
Anls Dat t-im Bac Result is greater than value reported A
The TIC is a suspected aldol-condensation product B
Target analyte was detected in the associated blank BD Results are either below the MDC or tracer recovery is low C
Analyte has been confirmed by GC/MS analysis D
Results are reported from a diluted aliquot of the sample H
Analytical holding time was exceeded J
Value is estimated N/A Spike recovery limits do not apply. Sample concentration exceeds spike concentration by 4X or more, R. Sample results are rejected U*. Analyte was analyzed for, but not detected above the MDL, MDA, or LOD.
LUI.
Gaima Spectroscopy-Uncertain identification X.. Consult Case Narrative, Data Summary package, or Project Manager concerning this qualifier Y
QC Samples were not spiked with this compound A
RPD of sample and duplicate evaluated using +/-RL. Concentrations are <5X the RL h
Preparation or preservation holding time was exceeded..
The above sample is reported on a dry weight basis.
44
.GENERAL ENGINEERING LABORATORIES, LLC 2040 Savage Road Charleston SC 29407 - (843) 556-8171 - www.gel.com Certificate of Analysis Company:
Connecticut Yankee Atomic Power Address:
362 Injun Hollow Rd East Hampton, Connecticut 06424
Contact:
IMr. Jack McCarthy Project:
Soils PO# 002332 Report Date: September 26, 2006 Client Sample ID:
Sample ID:
Matrix:
Collect Date:
Receive Date:
Collector:
Moisture:
9530-0004-016F 171454004 TS 24-AUG-06 12-SEP-06 Client 4.11%
Proiect:
Client ID:
Vol. Recv.:
YANK01204 YANK001 Parameter.
Qualifier Result Uncertainty LC TPU MDA Units DF Analyst Date Time Batch M; Rad Gamma Spec Analysis Ganua,oSolid-FSS GAM & ALL FSS 226 Ingrowth Waived Actinium-228 0.475
+/-0.180 0.0698
+/-0.180 0.155 pCi/g MJHI 09/20/06.0721 569467 Americium-241
- U
-0.0329
+/-0.103 0.0847
+/-0.103 0.178 pCi/g Bismuth-212 0.305
+/-0.215 0.124
+/-0.215 0.278 pCi/g Bismuth-214 0.459
+/-0.102 0.0331
+/-0.102 0.0728 pCi/g
- Cesium-134 U
0.0523
+/-0.0377 0.0247 +/-0.0377 0.0539 pCi/g Cesium-137 U
0.038
+/-0.0342 0.0203 +/-0.0342 0.0444 pCi/g Cobalt-60 U
-0.0109
+/-0.0209 0.0157 +/-0.0209 0.0374 pCi/g Europium-152 U
0.00609
+/-0.0548 0.0498 +/-0.0548 0.107 pCi/g
..Europium-154 U
0.0766
+/-0.0984 0.0595 +/-0.0984 0.135 pCi/g Europium-155 U
0.0319
+/-0.0647 0.0602 +/-0.0647 0.126 pCi/g Lead-212 0.572
+/-0.0667 0.0293 +/-0.0667 0.0621 pCi/g Lead-214 0.442
+/-0.101 0.0361
+/-0.101 0.0776 pCi/g*
0.0197
+/-0.0261 0.018 +/-0.0261 0.0402 pCi/g Niobium-94 U
0.00763
+/-0.0221 0.0195 +/-0.0221 0.0424 pCi/g Potassium-40 10.8
+/-1.02 0.175
+/-1.02 0.409 pCi/g Radium-226 0.459
+/-0.102 0.0331
+/-0.102 0.0728 pCilg Silver-108m U
0.006
+/-0.020 0.0181
+/-0.020 0.0391 pCi/g Thallium-208 0.155
+/-0.0531 0.0197 +/-0.0531 0.043 pCi/g The following Prep Methods were performed Method Description Analyst Date Time Prep Batch Dry Soil Prep Dry Soil Prep GL-RAD-A-021 AXP2 09/12/06 1739 567633 The following Analytical Methods were performed Method Description EML HASL 300,-4.5.2.3 Notes:
The Qualifiers in this report are defined as follows A quality control analyte recovery is outside of specified acceptance criteria Result is less than value reported 45
GENERAL ENGINEERING LABORATORIES, LLC 2040 Savage Road Charleston SC 29407 - (843) 556-8171 - www.gel.com Certificate of Analysis Company:
Connecticut Yankee Atomic Power Address:
362 Injun Hollow Rd East Hampton, Connecticut 06424 Report Date: September 26, 2006
Contact:
Mr. Jack McCart..y Project:
Soils PO# 002332 Client Sample ID:
9530-0004-0.1F Pro:ect:
YANK 1204 Sample ID:
171454004 Client ID:
yANK*.
Parameter Qualifier Result Uncertainty LC TPU MDA Units DF Analyst Date Time Batch Mt Result is greater than value reported A
The TIC is a suspected aldol-condensation product B
Target analyte was detected in the associated blank BD. Results are either below the MDC or tracer recovery is low
- C Analyte has been confirmed by GC/MS analysis
. D Results are reported from a diluted aliquot of the sample H
Analytical holding time yas exceeded J.
Value is estimated N/A Spike recovery limits do not apply. Sample concentration exceeds spike concentration by 4X or more R
Sample results are rejected U. Analyte was analyzed for, but not detected above the MDL, MDA, or LOD..
UI Gamma Spectroscopy--Uncertain identification X: Consult Case Narrative, Data Summary package, or Project Manager concerning this qualifier Y
QC Samples were not spiked with this compound A
RPD of sample and duplicate evaluated using +/-RL. Concentrations are <5X the RL.
It Preparation or preservation holding time was exceeded The above sample is reported on a dry weight basis.
46
GENERAL ENGINEERING LABORATORIES, LLC 2040 Savage Road Charleston SC 29407 - (843) 556-8171 - www.gel.comr Certificate of Analysis
.Company:
Connecticut Yankee Atomic Power Address:
362 Injun Hollow Rd East Hampton, Connecticut 06424
Contact:
Mr. Jack McCarthy Project:
Soils PO# 002332 Report Date: September 26, 2006
.Client Sample ID:
Sample iD:
Matrix:
Collect Date:
Receive Date:
Collector:
Moisture:
9530-0004-017F 171454005 TS
- 24-AUG-06 12-SEP-06 Client 6.96%
- Project:
Client ID:
Vol. Recv.:
YANK01204 YANK001 Parameter Qualifier Result Uncertainty LC TPU TVIDA Units DF Analyst Date Time Batch Mt Rad Gamma Spec Analysis Gammnn,Solid-FSS GAM & ALL FSS 226 Ingrowth Waived
- Actinium-228 UI 0.00
+/-0.182 0.147
+/-0.182 0.309 pCi/g MJHI 09/20/06 0722.569467:
- Americium-241 U
-0.0302
+/-0.110 0.0903
+/-0.1.10 0.188 pCi/g Bismuth-212 0.556
+/-0.334 0.130
+/-0.334 0,289 pCi/g Bismuth-2t4 0.521
+/-0.117 0.0374
+/-0.117 0.0809 pCi/g Cesium-134 U
0.024
+/-0.0288 0.0261 +/-0:0288 0.0565 pCi/g Cesium-137 U
0.00655
+/-0.0301 0.0229 +1-0.0301 0.0494 pCi/g Cobalt-60 U
0.00225
+/-0.0229 0.0195 +/-0.0229 0.0446 pCi/g Europium-152 U
0.013
+/-0.0697 0.0558 +/-0.0697 0.118
. pCi/g.
- Europium-154 U
-0.0237
+/-0.0778 0.0626 +/-0.0778 0.140 pCi/g.
Europium-!55 U
0.030
+/-0.0653 0.0603 +/-0.0653 0.126 pCi/g Lead-212 0.601
+/-0.0679 0.0291 +/-0.0679 0.0614 pCi/g Lead-214 0.620
.+/-0.102 0.0383
+/-0.102 0.0816 pCi/g Manganese-54 U
0.00167.
1-/-0.0245
.0.0216 +/-0.0245 0.047 pCi/g
- Niobium-94 U
0.0208
+/-0.025 0.0178
+/-0.025 0.0388 pCi/g Potassium-40 10.6
+/-1.00 0.184
+/-1.00 0.424 pCi/g Radium-226 0.521
+/-0.117 0.0374
+/-0.117 0.0809 pCi/g Silver-108m U -0.00771
+/-0.0186 0.0157 +/-0.0186 0.034 pCi/g Thallium-208 0.191
+/-0.0502 0,0183 +/-0.0502 0.040 pCi/g.
The following Prep Methods were performed Method Description Analyst Date Time Prep Batch Dry Soil Prep Dry Soil Prep GL-RAD-A-021 AXP2 09/12/06 1739 567633 The following Analytical Methods were performed Method Description I
EML HASL 300, 4.5.2.3 Notes:
The Qualifiers in this report art defined as follows:
A quality control analyte recovery is outside of specified acceptance criteria Result is less than value reported 47
GENERAL ENGINEERING LABORATORIES, LLC:."
2040 Savage Road Charleston SC 29407 - (843) 556-8171 - www.gel.com Certificate of Analysis Company:
Connecticut Yankee Atomic Power Address:
362 Injun Hollow Rd
- East Hampton, Connecticut 06424 Report Date:
September 26, 2006
Contact:
Mr. Jack McCarthy Project:
Soils PO# 002332 Client Sample ID:
.9530-0004-017F Project:
YANK01204 SampleID:
171454005 Client ID:
YANK*.
Vol. Recv.:
Parameter Qualifier Result Uncertainty LC TPU oDA Units DF Analyst Date Time Batch mi Result is greater than value reported A
The TIC is a suspected aldol-condensation product B
Target analyte was detected in the associated blank BD Results are either below the MDC or tracer recovery is low C
Analyte has been confirmed by GC/MS analysis.
D Results are reported from a diluted aliquot of the samnple H
Analytical holding time was exceeded J
Value is estimated
,N/A Spike recovery limits do not apply. Sample concentration exceeds spike concentration by 4X or more
.R Sample results are rejected U.
Analyte was analyzed for, but not detected above the lVIDL, IvDA, orLOD.
UI Gamma Spectroscopy--Uncertain identification X
Consult Case Narrative, Data Summary package, or Project Manager concerning this qualifier Y
QC Samples were not spiked with this compound A
RPD of sample and duplicate evaluated using +/-RL. Concentrations are <5X the RL h
Preparation or preservation holding time was exceeded The above sample is reported on a dry weight basis.
48
GENERAL ENGINEERING LABORATORIES, LLC 2040 Savage Road Charleston SC 29407 - (843) 556-8171 - www.gel.com Certificate of Analysis Company : Connecticut Yankee Atomic Powe&-
Address:
362 Injun Hollow Rd
Contact:
Project:
East Hampton, Connecticut 06424 Mr. Jack McCarthy Soils PO# 002332 Report Date: September 26, 2006 Client Sample ID:
Sample ID:
Matrix:
Collect Date:
Receive Date:
Collector:
Moisture:
- 9530-0004-018F 171454006 TS 24-AUG-06 12-SEP-06 Client 3.3%
Proiect:
YANK01204 Client ID:
YANK001
'Vol. Recv.:
Parameter Qualifier Result Uncertainty LC TPU MDA Units DF Analyst Date Time Batch Mt Rad Gamma Spec Analysis Ganzma,Solid-FSS GAM & ALL FSS 226 Ingrowthl Waijved Actinium-228 0.626
+/-0.156 Americium-241 U
0.0455
+/-0.108 Bismuth-212 0,382
+/-0.211 Bismuth-214 0.535
+/-0.077 Cesium-134 U
0.0227
+/-0.0191 Cesium-137 0.0361
+/-0.0215 Cobalt-60 U -0.00248
+/-0.0167 Europium-152 U
-0.0163
+/-0.0429 Europium-154 U
-0.0313
+/-0.0509 Europium-155 U
0.00434
+/-0.0492 Lead-212
- 0.659
+/-0.0724 Lead-214 0.656
+1-0.0864 Manganese-54 U
0.0109
+/-0.0162 Niobium-94 U
-0.0118
+/-0.0137 Potassium-40 10.4
+/-1.01 Radium-226 0.535
+/-0.077 Silver-lO8tn U-0.000948
+/-0.0134 Thallium-208 0.212
+/-0.0388 0.0447 0.0895 0.0947 0.0231 0.0179 0.0139 0.0138 0.0373 0.0402 0.0439 0.021 0.0263 0.0127 0.0114 0.116 0.0231 0.0116 0.0144
+1-0.156
+/-0.108
+/-0.211
+/-0.077
+/-0.0191
+/-0.0215
+/-0.0167
+/-0.0429
+/-0.0509
+/-0.0492
+/-0.0724
+/-0.0864
+/-0.0162
+/-0.0137
+/-1.01
+/-0.077
+/-0.0134
+/-0.0388 0.0959 0.184 0.202 0.049
- 0.0378 0.0295 0.0301 0.0777 0.0871 0.0903 0.0433 0:0548 0.0271 0.0242 0.257.
0.049 0.0245 0.0303 pCi/g
.pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCilg pCi/g
.pCi/g
- pCi/g
- pCi/g pCi/g pCi/g MJH1 09/20/06 0722 569467 The following Prep Methods were performed Method Description Analyst.
Date Time Prep Batch Dry Soil Prep Dry Soil Prep GL-RAD-A-021 AXP2
.09/12/06 1739 567633 The following Analytical Methods were performed Method- -
Description-1 EIvIL HASL 300, 4.5.2.3 Notes:
The Qualifiers in this report are defined as follows:
q: A quality control analyte recovery is outside of specified acceptance criteria Result is less than value reported 49
GENERAL ENGINEERING LABORATORIES, LLC 2040 Savage Road Charleston SC 29407 - (843) 556-8171 - www.gel.comr Certificate of Analysis Company:
Connecticut Yankee Atomic Power Address:
362 Injun Hollow Rd East Hampton, Connecticut 06424 Report Date:
September.26, 2006
Contact:
Mr. Jack McCarthy Project:
Soils PO# 002332 Client Sample ID:
9530-0004-01817 Project:
YANK01204 Sample ID:
.171454006 Client ID:
yANKO0i Vol. Recv.:
Parameter Qualifier Result Uncertainty LC TPU MDA Units DF Analyst Date Tine Batch Mi Result is greater than value reported A
The TIC is a suspected aldol-condensation product B
Target analyte was detected in the associated blank BD Results are either below the MDC or tracer recovery is low C
Analyte has been.onfmnned by GC/MS analysis D
Results are reportedfrom a diluted aliquot of the sample H
Analytical holding time was exceeded J
Value is estimated
- N/A-Spike recovery limits do not apply. Sample concentration exceeds spike concentration by 4X or more R
Sample results are rejected
.U Analyte was analyzed for, but not detected abovethe MDL, MDA, or LOD.
UI
.Gamma Spectroscopy-Uncertain identificatio_'
X
- Consult Case Narrative, Data Summary package, or Project Manager concerning this qualifier Y
QC Samples were not spiked with this compound A
RPD of sample and duplicate evaluated using +/-RL. Concentrations are <5X the RL h
Preparation or preservation holding time was exceeded The above sample is reported on a dry weight basis.
50
GENERAL ENGINEERING LABORATORIES, LLC 2040 Savage Road Charleston SC 29407 - (843) 556-8171 - www.gel.com Certificate of Analysis Company:
Connecticut Yankee Atomic Power Address:
- 362 Injun Hollow Rd East Hampton, Connecticut 06424
Contact:
Mr. Jack McCarthy Project:
Soils PO# 002332 Report Date: September 26, 2006.
Client Sample ID:
Sample ID:
Matrix:
Collect Date:
Receive Date:
Collector:
Moisture:
9530-0004-004F 171454007 TS 25-AUG-06 12-SEP-06.
Client 6.7%
Project:
YANK01204 Client ID:
YANK001
.Vol. Recv.:
Parameter Qualifier Result Uncertainty LC TPU lVMDA Units DF Analyst Date Time Batch Mt Rad Gamma Spec Analysis Gamma,Solid-FSS GAM & ALL FSS 226 hrgrowth Waived Actinium-228 0.625
+/-0.130 0.0674
+/-0.130 0.145 pCi/g MJHI 09/20/06 0723 569467
. Americium-241 U
-0.178
+/-0.108 0.081
+/-0.108 0.167 pCi/g Bismuth-212 0.550
+/-0.210 0.152
+/-0.210 0.324 pCi/g Bismuth-214
.0.550
+/-0.0874 0.0412 +/-0.0874 0.0868 pCi/g Cesium-134 U
0.0362
+/-0.0261 0.0235 +/-0.0261 0.0501 pCilg Cesium-137 U
0.0297
+/-0.0232 0.0198 +/-0.0232 0.0421 pCi/g Cobalt-60 U
0.017
+/-0.011 0.0182
+/-0.011
.0.0404 pCilg Europium-152 U -0.00823
+/-0.056 0.0472
+/-0.056 0.0993 pCi/g
- Europium-154 U
0.0848
+/-0.0746 0.0691 +/-0.074,
.0.149 pCi/g Europium-155 U
-0.0214
+/-0.0621 0.0552 +/-0.0621 0.114 pCi/g Lead-212 0.661
+/-0.0612 0.0279 +/-0.0612 0.0582 pCi/g Lead-214
.0.561
+/-0.0893 0.0338 +/-0.0893 0.0712 pCi/g Manganese-54 U -0.00978
+/-0.0219 0.018 +/-0.0219 0.0387 pCi/g Niobium-94 U
0.00656
+/-0.0286 0.0152 +/-0.0286 0.0326 pCi/g Potassium-40 11.5
+/-0.843 0.!:66
+/-0.848 0.372 pCi/g Radium-226 0.550
+/-0.0874 0.0412 +/-0.0874 0.0868 pCi/g Silver-108m U
0.00429
+/-0.0202 0.0172 +/-0.0202 0.0363 pCi/g.
Thallium-208 0.222
+/-0.0447 0.0174 +/-0.0447 0.0372 pCi/g The following Prep Methods were performed Method Description Analyst Date Time Prep Batch Dry Soil Prep Dry Soil Prep GL-RAD-A-021 AXP2 09/12/06 1739 567633 The following Analytical Methods were performed
--Method - ----
E-.D sc4...
I EML. HASL 300, 4.5.2.3 Notes:
The Qualifiers in this report are defined as follows A quality control analyte recovery is outside of specified acceptance criteria Result is less than value reported 51
GENERAL ENGINEERING LABORATORIES, LLC 2040 Savage Road Charleston SC 29407 - (843) 556-8171.- www.gel.com Certificate of Analysis Company Connecticut Yankee Atomic Power Address:
362 Injun Hollow Rd East Hampton, Connecticut 06424 Report Date: September 26, 2006
Contact:
Iv.. Jack McCarthy Project:
Soils PO# 002332 Cliet Sample ID:
9530-0004-0045.'ect YANK0 1204 Sample ID:
171454007 Client ID:
yANKOO.
Vol. Recv.:
Parameter Qualiflier Result Uncertainty LC TPU AMA Units DF Analyst Date Time Batch Mt Result is greater than value reported A
The TIC is a suspected aidol-condensation product B
Target analyte was detected in the associated blank BD Results are either below the MDC or tracer recovery is low C
Analyie has been confirr:;ed by GC/MS analysis
- D Results are reported from a diluted aliquot of the sample HI Analytical holding time was exceeded J
Value is estimated N/A Spike recovery limits do not apply. Sample concentration exceeds spike concentration by 4X or more R - Sampleresults are rejected
.U Analyte was analyzed for, but not detected above the MDL, MDA, or LOD.
I Gamma Spectroscopy--Uncertain identification X
Consult Case Narrative, Data Summary package, or Project Manager concerning this qualifier Y
QC Samples were not spiked with this compound A RPD of sample and duplicate evaluated using +/-RL. Concentrations are <5X the RL h
Preparation or preservation holding time was exceeded The above sample is reported on a dry weight basis.
52
GENERAL ENGINEERING LABORATORIES, LLC 2040 Savage Road Charleston SC 29407 - (843) 556-8171 - www.gel.com Certificate of Analvsis Company:
Connecticut Yankee Atomic Power
" Address:
362 Injun Hollow Rd East Hampton, Connecticut 06424
Contact:
Mr. Jack McCarthy Project:
Soils PO# 002332 Report Date: September 26, 2006 Client Sample ID:
Sample ID:
Matrix:
Collect Date:
Receive Date:
Collector:
Moisture:
- 9530-0004-004FS 171454008 TS
.25-AUG-06 12-SEP-06 Client 4.18%
Project:
Client ID:
Vol; Recv.:
YANK01204 YANK001 Parameter Qualifier Result Uncertainty LC TPU M1)DA Units DF.. Analyst Date Time Batch Mt Rad Gamma Spec Analysis GanunaSolid-FSS GAM & ALL FSS 226 hIgrowth Waived Actinium-228 0.771 Americium-241 U
-0.0196 Bismuth-212 0.565
- Bismuth-214 0.668 Cesium-134 U
0.00945 Cesium-137 U
0.0558 Cobalt-60 U 0.000294 Europium-152 U
0.0515 Europium-154 U
-0.08 Europium-155 U
-0.0366.
Lead-212 0.561 Lead-214 0.601 Manganese-54 U
0.00942 Niobium-94 U
-0.0202 Poiassium-40 11.2 Radium-226 0.668 Silver-10m U -0.00614 Thallium-208 0.246
+/-0.237
+/-0.0434
+/-0.379
+/-0.149
+/-0.0395
+/-0.0628
+/-0.0343
+/-0.0793
+/-0.102
+/-0.0744
+/-0.092
+/-0.130
+/-0.0343
+/-0.0312
+/-1.34
+/-0.149
+/-0.027
+/-0.0735 0.0932 0.0374 0,248 0.0532 0:0338 0.0283 0.0287 0.0704 0.0769
., 0.061 0.0497 0.0421 0.0294 0.0249 0.284 C.0532 0.0236 0.0299
+/-0.237
+1-0.0434
+1-0.379
+/-0.149
+/-0.0395
+/-0.0628
+/-0.0343
+/-0.0793
+/-0.102
+/-0.0744
+/-0.092
+/-0.130
+/-0.0343
+/-0.03'- 2
+/-1.34
+/-0.149
+/-0.027
+/-0.0735
.0.204 0.0776 0.529 0.114 0.0726 0.0608 0.0638 0.149 0.171 0.127 0.103 0.090 0.0634 0.0536 0.632 0.114 0.0303 0.0637 pCi/g pCi/g pCi/g
'ipCilg pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g MJH1..09/20/06 0723 569467 The following Prep Methods were performed Method Description Analyst Date Time Prep Batch Dry Soil Prep Dry Soil Prep GL-RAD-A-021 AXP2
.09/12/06 1740 567633 The following Analytical Method& were performed Method Description 1EIML HASL 300.- 4.5.2.3 Notes:
The Qualifiers in this report are defined as follows A quality control analyte recovery is outside of specified acceptance criteria Result is less than value reported 53
GENERAL ENGINEERING LABORATORIES, LLC 2040 Savage Road Charleston SC 29407 - (843) 556-8171 - www.gel.com Certificate of Analysis Company:
Connecticut Yankee Atomic Power.
Address:
362 Injun Hollow Rd Contc:
East Hampton, Connecticut 06424 Report Date:
September 26, 2006
Contact:
Mr. Jack McCarthy Project:
Soils PO# 002332 Client Sample ID:.
9530-0004-004FS Project:
YANK01204 Sample ID:
171454008
" Client ID:
YANKO0 Vol. RecvU Parameter
.Qualifier ReSult Uncertainty LC TPU MDA Units DF Analyst Date Time Batch MI Result is greater than value reported A
The TIC is a suspected aldol-condensation product B
Target analyte was detected in the associated bla-*ik BD... Results are either below the MDC or tracer recovery is low C
Analyte has been confirmed by GC/MS analysis D
Results are reported from a diluted aliquot of the sample H
Analytical holding time was exceeded
- J Value is estimated N/A. Spike recovery limits do not apply. Sample coacentration exceeds spike concentration by 4X or more R
Sample results are rejected U
Analyte was analyzed fo.., but not detected above the YVBDL, MDA, or LOD.
UI Garmna Spectroscopy-Uncertain identification
.X Consult Case Narrative, DataSummary package, or Project Manager concerning this qualifier Y
QC Samples werenot spiked with this compound A RPD of sample and duplicate evaluated using +/-RL. Concentrations are <5X the RL h
Preparation or preservation holding time was exceeded The above sample is reported on a dry weight basis.
54
GENERAL ENGINEERING LABORATORIES, LLC 2040 Savage Road Charleston SC 29407 - (843) 556-8171 - www.gel.com Certificate of Analysis Company:
Connecticut Yankee Atomic Power Address:
362 Injun Hollow Rd East Hampton, Connecticut 06424
Contact:
Mr. Jack McCarthy project:
Soils PC# 0023.32 Report Date: September 26, 2006 Client Sample ED:
Sample ID:
Matrix:
Collect Date:
Receive Date:
Collector; Moisture:
9530-0004-009F 171454009 TS
- 25-AUG-06 12-SEP-06 Client 8.71%
Proiect:
YANK01204 ClientiD:
YANK001 Vol. Recv.:
Parameter Qualifier Result Uncertainty LC TPU IVIDA Units DF Analyst Date Time Batch Mt Rad Gamma Spec Analysis Gamnmna,Solid-FSS GAM & ALL FSS 226 Ingrowth Waived Actinium-228 0.796
+/-0.210 0.0813
+/-0.210 0.180 pCi/g MJI-11 09/20/06 0724 569467 Ameiicium-241 U
-0.0113
+/-0.0322 0.0269 +/-0.0322 0.0561 pCi/g Bismuth-212 0.521
+/-0.316 0.162
+/-0.316 0.357 pCi/g Bismuth-214 0.432
+/-0.102 0.0393
+/-0.102 0.0855 pCi/g Ccsium-134 U
0.01 14
+/-0.0354 0.0303 +/-0.0354 0.0655 pCi/g Cesium-137 0.136
+/-0.0513 0.0216 +1-0.0513 0.0472 pCi/g Cobalt-60 U
0.00715
+/-0.0315 0.0271 +/-0.0315 0.0607 pCi/g Eur0opium-152 U
-0.0617
+/-0.066 0.0503
+1-0.066
.0.108 pCi/g Europium-154 U
0.00312
+/-0.0772 0.0649 +/-0.0772 0.148 pCi/g Europium-155 U
0.0766
+/-0.0734
.0.0442
+/-0.0734 0.0929.
pCi/g
.Lead-212 0.736
+/-0.0739 0.031 +/-0.0739 0.0654 pCi/g Lead-214 0.496
+/-0.108 0.0415
+/-0.108 0.0883 pCi/g Manganese-54 U
0.0083
+/-0.0279 0.0239 +/-0.0279 0.0523 pCi/g Niobium-94 U
0.018
+/-0.0244 0.0221 +/-0.0244 0.0478 pCi/g Potassium-40 10.7
+/-1.14 0.229
+/-1.14 0.524 pCi/g Radium-226 0.432
+/-0.102 0.0393 4-0.102 0.0855 pCi/g Silver-t08m U -0.00149
+/-0.0224 0.0196 +/-0.0224 0.042 pCi/g Thallium-208 0.216
+/-0.0547 0.02i3 +/-0.0547 0.0464 pCi/g The following Prep Methods were performed Method Description Analyst Date Time Prep Batch Dry Soil Prep Dry Soil Prep GL-RAD-A-021 AXP2 09/12/06 1740 567633 The following Analytical Methods were performed Method Description I
EML HASL 300, 4.5.2.3
.Notes:
The Qualifiers in this report are defined as follows A quality control analyte recovery is outside of specified acceptance criteria Result is less than value reported 55
GENERAL ENGINEERING LABORATORIES, LLC 2040 Savage Road Charleston SC 29407 - (843) 556-8171 - www.gelxcom Certificate of Analysis Company:
Connecticut Yankee Atomic Power Address:
362 Injun Hollow Rd East Hampton, Connecticut 06424, Report Date:
September 26, 2006
Contact:
'Mr. Jack McCarthy Project:
Soils PO# 002332 Client Sample ID:
9530-0004-009F Project:
YANK01204..
SampleD:
171454009 Client ID:
YANKOQI Vol. Recv.:
Parameter Qualifier Result Uncertainty LC TPU MDA Units DF Analyst Date Time Batch MI Result is greater than value reported A
The TIC is a suspected aldol-condensation product B
Target analyte was detected in the associated blank BD Results are either below the MDC or tracer recovery is low C
Analyte has been confirmed by GC/MS analysis D
Results are reported from a diluted aliquot of the sample
- H Analytical holding time was exceeded J
Value is estimated N/A Spike recovery limits do not apply. Sample concentration exceeds spike concentration by 4X or more R
Sample results are rejected U
Analyte was analyzed for, but not detected above the MDL, MDA, or LOD.
UI Gamma Spectroscopy--,Uncertain identification X
Consult Case Narrative, Data Summary package, or Project Manager concerning this qualifier Y
QC Samples were not spiked with this compound A
RPD of sample and duplicate evaluated using +/-RL. Concentrations are <5X the RL h
Preparation or preservation holding time was exceeded The above sample is reported on a dry weight basis.
56
GENERAL ENGINEERING LABORATORIES, LLC 2040 Savage Road Charleston SC 29407 - (843) 556-8171 - www.gel.com Certificate of Analysis Company:
Connecticut Yankee Atomic Power Address:
362 Injun Hollow Rd East Hampton, Connecticut 06424
Contact:
Mr. Jack McCarthy Project:
Soils PO# 002332 Report.Date:
September 26, 2006 Client Sample ID:
Sample ID:
Matrix:
Collect Date:
Receive Date:
Collector:
Moisture:
9530-0004-009FS
.171454010
.TS 25-AUG-06 12-SEP-06 Client 6.35%
Project:
Client ID:
Vol. Recv.:
YANK01204 YANK001 Parameter Qualifier Result Uncertainty LC TPU MDA Units DF Analyst Date Time Batch M'It Rad Gamma Spec Analysis Gamma,Solid-FSS GAM & ALL FSS 226 Ingrowth Waived Actinium-228 0.658
+/-0.175 0.0526
+/-0.175 0.112 pCi/g MJHI 09/20/06 0724 569467 1
0.100
+/-0.112 0.090
+/-0.112 0.186 pCi/g Bismuth-212 0.535
+/-0.217 0.110
+o-0.217 0.235 pCi/g Bismuth-214:
0.444
+/-0.0706 0.0301 +/-0.0706 0.0634 pCi/g" Cesium-134 U
0.0214
+/-0.0286 0.020 +/-0.0286 0.0421 pCi/g Cesium-137 0.111
+/-0.0364 0.0153 +/-0.0364 0.0324
.pCi/g Cobalt-60 U 0.000951
+/-0.0165 0.0142 +/-0.0165 0.0311 pCi/g
. Europium-152 U -0.00693
+/-0.0462 0.0402 +/-0.0462 0.0841 pCi/g Europium-154 U
0.00194
+/-0.0552 0.0474 +/-0.0552 0.102 pCi/g
- Er'opium-155.
U 0.00476
+/-0.0574 0.0512 +/-0.0574 0.106 pCi/g Lead-212 0.763
+/-0.057 0.0235
+/-0.057 0.0489 pCi/g Lead-214 0.587
+/-0.0729 0.0274 +/-0.0729 0.0576 pCi/g Manganese-54 U
-0.0147
+/-0.0184 0.0148 +/-0.0184 0.0316 pCi/g Niobium-94 U
0.00168
+/-0.0166 0.0145 +/-0.0166 0.0305 pCi/g.
Potassium-40 12.1
+/-0.774 0.146
+/-0.774 0.320 pCi/g Radium-226 0.444
+/-0.0706 0.0301 +/-0.0706 0.0634 pCi/g.
Silver-108m U
0.00543
+/-0.0153 0.0135 +/-0.0153 0.0283 pCi/g Thallium-208 0.200
+/-0.028 0.0136
+/-0.038 0.0288 pCi/g The following Prep Methods were performed Method Description Analyst Date Time Prep Batch Dry Soil Prep Dry Soil Prep GL-RAD-A-021 AXP2
. 09/12/06 1740 567633 The following Analytical Methods were performed Method Description EML HASL 300.4.5.2.3 Notes:
The Qualifiers in this report are defined as follows A quality control analyte recovery is outside of specified acceptance criteria Result is less than value reported 57
GENERAL ENGINEERING LABORATORIES, LLC 2040 Savage Road Charleston SC 29407 - (843) 556-8171 - www.gel.com Cer-tificate of Analysis Company Connecticut Yankee Atomic Power Address:
362 Injun Hollow Rd East Hampton, Connecticut 06424 Report Date:
September 26, 2.006
Contact:
Mr. Jack McCart*y Project:
Soils PO# 002332
- Cient Sample D:
9530-0004-OO9FS Project:
YANK01204
.C.nple ID:
171454010 Client ID:
YAN"K Vol. Recv.:
Parameter Quailffier Result Uncertainty LC TPU.
MDA Units DF Analyst Date Time Batch Mt, Result is greater than value reported A
The TIC is a suspected aldol-condensation product B
Target analyte was detected in the associated blank BD Results are either below the MDC or tracer recovery is low C
Analyte has been confirmed by GC/MS analysis D
Results are reported from a diluted aliquot of the sample H
Analytical holding time was exceeded J
Value is estimated N/A Spike recovery limits dý` not apply. Sample concentration exceeds spike concentration by 4X or more R
Sample results are rejected U
Analyte was analyzed for, but not detected above the MDL, MDA, or LOD.
UI Gamma Spectroscopy-Uncertain identification X
Consult Case Narrative, Data Summary package, or Project Manager concerning this qualifier Y
QC Samples were not spiked with this compound A
RPD of sample and duplicate evaluated using +/-RL. Concentrations are <5X the RL h
Preparation or preservation holding time was exceeded The above sample is reported on a dry weight basis.
58
GENERAL ENGINEERING LABORATORIES, LLC 2040 Savage Road Charleston SC 29407 - (843) 556-8171 - www.gel.com "Certificate of Analysis Company Connecticut Yankee Atomic Power Address:
362 Injun Hollow Rd East Hampton, Connecticut 06424
Contact:
Mr. Jack McCarthy Project:
Soils PO# 002332 Report Date: September 26, 2006 Client Sample ID:
- 9530-0004-013F Project:
YANK01204 Sample ID:
.171454011 Client ID:
YANK001 Matrix:
TS Vol. Recv.:
Collect Date:
25-AUG-06 Receive Date:
12-SEP-06 Collector:
Client Moisture:
4.27%
Parameter Qualifier Result Uncertainty LC TPU LVIDA Units DF Analyst Date Time Batch Mt Rad Gamma Spec Analysis Gamnia, Solid-FSS GAM &ALL FSS 226 Ingrowth Waived Actinium-228 0.590 Americium-241 U
-0.0387 Bismuth-212..
0.437
- Bismuth-214 0.487 Cesium-134 U
0.0249 Cesium-137 0.087 Cobalt-60 U
0.00393 Europium-152 U
00367 Europium-154 U
0.059 Europium-155.
U 0.0356 Lead-212 0.666 Lead-214 0.516 Manganese-54
. U -0.00266 Niobium-94 U
0.00307 Potassium-40 10.8 Radium-226 0.487 Silver-108m U
-0.0125 Thallium-208 0.222
+/-0.165
+/-0.0866
+/-0.306
+/-0.0886
+/-0.0242
+1-0.0401
+/-0.0215
+/-0.0557
+/-0.0639
+/-0,0609
+/-0.0695
+/-0.0796
+/-0,0215
+/-0.0188
+/-0.864
+/-0.0886
+1-0.0183
+/-0.0469 0.0542 0.0672 0.126 0.0359 0.0225 0.0171 0.0181 0.0502 0.0585 0.0543 0.028 0.0344 0.0182 0.0165 0.158 0.0359 0.0147 0.0163
+/-0.165
+/-0,0866
+/-0.306
+/-0.0886
+/-0.0242
+/-0.0401
+/-0.0215
+/-0.0557
+/-0.0639
+/-0.0609
+/-0.0695
+/-0.0796
+/-0.0215
+/-0.0188
+/-0.864
+/-0.0886
+/-0.0183
+/-0.046-9 0.119 0.140:
0.274 0.0764 0.0482 0.0368 0.0402 0.106 0.128 0.113 0.0586 0.0728 0,0392 0.0354 0.355 0.0764 0.0315 0.0351 pCi/g-PCi/g' pCi/g pCi/g
.pCi/g
- pCi/ga pCi/g-pCi/.g pCi/g pCi/g pCilg'
.pCi/g pCilg PC pi/g pCi/g pCi/g-pCi/g pCi/g MJHI. 09/20/06 0725 569467
- The following Prep Methods were performed Method Description Analyst Date Time Prep Batch Dry Soil Prep Dry Soil Prep GL-RAD-A-021 AXP2 09/12/06 1740
.567633 The following Analytical Methods were performed
--/etlihd-Description-.
1 EML HASL 300,'4.5.2.3 Notes:
The Qualifiers in this report are. defined as follows:
A quality controlanalyte recovery is outside of specified acceptance criteria Result is less than value reported 59
GENERAL ENGINEERING LABORATORIES, LLC 2040 Savage Road Charleston SC 29407- (843) 556-8171 -. www.gel.comr Certificate of Analysis Company:
Connecticut Yankee Atomic Power Address:
362 lnjun Hollow Rd East Hampton, Connecticut 06424 Report Date: September 26, 2006
Contact:
Mr. Jack McCarthy Project:
Soils PO# 002332 Client Sample ID:
9530-0004-013F Project:
YANK.01204 Sample ID:
171454011 Client ID:
YANK00O Vol. Recv.:
Parameter Qualifier Result Uncertainty LC TPU MIIDA Units DF Analyst Date Time Batch Mt.
Result is greater that. value reported A'
The TIC is a suspected aldol-condensation product B
Target analyte was detected in the associated blatk BD Restlts are either below the MDC or tracer recovery is low
- C Analyte has been confirmed by GCiMS analysis D
Results are reported from a diluted aliquot of the sample
.H Analytical holding time was exceeded
.J Value is estimated N/A Spike recovery limits do not apply. Sample concentration exceeds spike concentration by 4X or more R
Sample results are rejected
.U Analyte was analyzed for, but not detected above the MDL, MDA, or LOD.,
U!
Ganmia Spectroscopy-- Uncertain identification X* Consult Case Narrative, Data Summary package, or Project Manager concerning this qualifier Y
QC Samples were not spiked with this compound A
RPD of sample and duplicate evaluated using +/-RL. Concentrations are <5X the RL
- h Preparation or preservation holding time was exceeded The above sample is [reported on a dry weight basis.
60
GENERAL ENGINEERING LABORATORIES, LLC 2040 Savage Road Charleston SC 29407 - (843) 556-8171 - www.gel.com Certificate of Analysis Company:
Connecticut Yankee Atomic Power Address:
362 Injun Hollow Rd East Hampton, Connecticut 06424
Contact:
Mr. Jack McCartdiy Project:
Soils PO# 002332 Report Date: September 26, 2006 Client Sample ID:
Sample ID:
Matrix:
Collect Date:
Receive Date:
Collector:
Moisture:
- 9530-0004-001F 171454012 TS 25-AUG-06 12-SEP-06 Client 2.72%
Proiect:
Client ID:
Vol. Recv.:
YANK01204 YANK001 Parameter Qualifier Result Uncertainty LC TPU MDA.
Units DF Analyst Date Time Batch Ml Rad Gamma Spec Analysis GanmMa, Solid-FSS GAM & ALL FSS 226 Ingrowth Waived Actinium-228 0.994
+/-0.222 0.0757
+/-0.222 0.165 pCi/g MJH1 09/26/06 0914 569467 Americium-241 U
0.116
+/-0.0935 0.0808 +/-0.0935 0.168 pCi/g Bismuth-212
.0.613
+/-0.300 0.137
+/-0.300 0.301 pCi/g Bismuth-214 0.524
+/-0.110 C.0351
+/-0.l1(:
0.0757 pCi/g Cesium-134 UI
.0.00
+/-0.0359 0.0281 +/-0.035
" 0.0602 pCi/g Cesium-137 0.141
+/-0.0422 0.021 +/-0.0422 0.0453 pCi/g Cobalt-60 U
0.00817
+/-0.0252 0.0223 +/-0.0252 0.050 pCi/g' Europiurm-152 U
-0.0137
+/-0.061 0.0492
+/-0.061 0.105 pCi/g Europium-154 U
-0.0236
+/-0.073 0.0596
+/-0.073 0.134
.pCi/g Europium-155" U
0.0822
+/-0.093t 0.0572 +/-0.0931 0.119 pCi/g Lead-212
- 0.912
+/-0.076 0.0308
+/-0.076 0.0645 pCi/g Lead-214 0.701
+/-0.0931 0.0401 +/-0.0931 0.0846 pCi/g Manganese-54 U
0.0353
+/-0.0318 0.0234 +/-0.0318 0.0504 pCi/g Niobium-94 U -0.00172
+/-0.0241 0.0202 +/-0.0241 0,0433 pCi/ga Potassium-40 13.3
+/-1.10 0.179
+/-1.10 0.412 pCi/g Radium-226 0.524
+/-0.110 0.0351
+/-0.110 0.0757 pCi/g Silver-108m U
-0.0112
+/-0.0199 0.0166 +/-0.0199 0,0356 pCi/g Thallium-208 0.313
+/-0.0551 0.0194 +/-0.0551 0.0418,
pCi/g.
The following Prep Methods were performed Method Description Analyst Date Time Prep Batch Dry Soil Prep Dry Soil Prep GL-RAD-A-021 AXP2
. 09/12/06 1740 567633 The folloNwing Analytical Methods were performed Method Description I
EEML HASL 300, 4.5.2.3 Notes:
The Qualifiers in this report are defined as follows A quality control analyte recovery is outside of specified acceptance criteria Result is less than value reported 61
GENERAL ENGINEERING LABORATORIES, LLC 2040 Savage Road Charleston SC 29407 - (843) 556-8171 - www.gel.com Certificate of Analysis Company:
Connecticut Yankee Atomic Power Address:
362 Injun Hollow Rd East Hampton, Connecticut 06424 Report Date: September 26, 2006
Contact:
Mr.. Jack McCarthy Project:
Soils PO# 002332 Client Sample ED:
9520-0004-001F Proiect:
YAINK01204 Sample ID:
171454012 ClientID:
YANKOO I Vol. Recv.:
Parameter Qualifier Result Uncertainty LC TPU IVIDA Units DF Analyst Date Time Batch Mt Result is greater than value reported A
The TIC is a suspected aldol-condensation product B
Target analyte was detected in the associated blank
- BD Results are either below the MDC or tracer recovery is low C
Analyte has beun confirmed by GC/MS analysis D
Results are reported from a diluted aliquot of the sample H
Analytical holding time was exceeded J
Value is estimated N/A Spike recovery limits do not apply. Sample concentration exceeds spike concentration by 4X or more
- R Sample results are rejected
UTI Gamma Spectroscopy--Uncertain identification X
Consult Case Narrative, Data Summary package, or Project Manager concerning this qualifier Y
QC"Samples were not spiked with this compound A
RPD of sample and duplicate evaluated using +/-RL. Concentrations are <5X the RL h
Preparation or preservation holding time was exceeded The above sample is reported on a dry weight basis.
62
GENERAL ENGINEERING LABORATORIES, LLC 2040 Savage Road Charleston SC 29407 - (843) 556-8171 - www.gel.com
-Certificate of Analysis Company :
Connecticut Yankee Atomic Power Address:
362 Injun Hollow Rd East Hampton, Connecticut 06424 Cohtact:
Mr. Jack McCarthy Project:
Soils PO# 002332 Report Date:. September 26, 2006 Client Sample ID:
Sample ID:
Matrix:
Collect Date:
Receive Date:
Collector:
Moisture:
9530-0004-019F 171454013 TS 25-AUG-06
- 12-SEP-06.
Client 2.88%
Project:
YANK01204 Client ID:
YANK001 Vol. Recv.:
Parameter Qualifier Result Uncertainty LC TPU MDA Units DF Analyst Date Time Batch lyMt Rad Gamma Spec Analysis Gaomma, Solid-FSS GAM & ALL FSS 226 Ingrowth Waived Actinium-228 0.430
+/-0.160 0.0604
+/-0.160 0.133 pCi/g MIlJHI 09/20/06 0959 569467 Americium-241 U
-0.0202
+/-0.0823 0.0699 +/-0.0823 0.146 pCi/g Bismuth-212 0.398
+/-0.280 0.139
+/-0.280 0.302 pCig" BismuDth-214 0.290
+/-0.0746 0.0318 +/-0.0746 0.0689 pCi/g Cesium-134 U
.0.0205
+/-0.0258 0.0212 +/-0.0258 0.0461 pCi/g Cesium-137 0.0965
+/-0.0401 0.0163 +/-0.0401 0.0356 pCi/g Cobalt-60 U. -0.00929
+/-0.0207 0.0163 +/-0.0207 0.0375 pCi/g Europium-152
'U 0.00784
+/-0.0555 0.0502 +/-0.0555 0.106 pCi/g Europium-154 U
0.00677
+/-0.0641 0.0559 +/-0.0641 0.125 pCi/g Europium-155 U
-0.0223
+/-0.0537.
0.0485 +/-0.0537 0.102 pCi/g" Lead-212 0.441
+/-0.0603 0.027 +/-0.0603 0.0567 pCi/g Lead-214 0.366
+/-0.0751 0.0321 +/-0.0751 0.G684 pCi/g Manganese-54 U
-0.017
+/-0.0193 0.0147 +/-0.0193 0.0328 pCi/g Niobium-94 U
0.00684
+/-0.018 0.0165
+/-0.018 0.0356 pCi/g Potassium-40 10.2
+/-0.945 0.151
+/-0.945 0.349 pCi/g Radium-226 0.290
+/-0.074ý*
0.0318 +/-0.0746 0.0689 pCi/g Silver-108m U
0.00949
+/-0.017 0.0157
+/-0.017 0.0336 pCi/g Thallium-208 0.151
+/-0.0441 0.0183 +1-0.0441 0.0395 pCi/g The following Prep Methods were performed Method Description Analyst Date.
Time Prep Batch Dry Soil Prep Dry Soil Prep GO,-RAD-A-021
- AXP2 09/12/05 1740 567633 The following Analytical Methods were performed Method Description 1
EML HASL 300, 4.5.2.3 Notes:
The Qualifiers in this report are defined as follows A quality control analyte recovery is oulside of specified acceptance criteria Result is less than value reported 63
GENERAL ENGINEERING LABORATORIES, LLC 2040 Savage Road Charleston SC 29407 - (843) 556-8171 - www.gel.com Certificate of Analysis Company:
Connecticut Yankee Atomic Power Address:
362 Injun Hollow Rd
- East Hampton, Connecticut 06424.:
Report Date: Septembcr 26, 2006
Contact:
Mr. Jack McCarthy Project:
Sails PO# 002332.
Client Sample ID:
9530-0004-019F.
Project:
YANK01204 Sample ID:
.171454013 Client ID:. YANK001*
Vol. Recv.:
Parameter Qualifier Result Uncertainty LC TPU MDA Units DF Analyst Date Time Batch Mt Result is greater than value reported A
The TIC is a suspected aldol-condensation product B
Target analyte was detected in the associated blank BD. Results are either below the MDC or tracer recovery is low C
Analyte has been confirmed by GCIMS analysis D
Results are reported froru a diluted aliquot of the sample H. Analytical holding time was exceeded J
Value is estimated N/A Spike recovery linits do not apply. Sample concentration exceeds spike concentration by 4X or more R
Sample results are rejected U
Analyte was analyzed for, but not detected above the MDL, MDA, or LOD.
UI Gamma Spectroscopy--Uncertain identification X
Consult Case Narrative, Data Summary package, or Project Manager concerning this qualifier Y
QC Samples were not spiked with this compound A
RPD of sample and duplicate evaluated using +/-RL. Concentrations are <5X the RL h
Preparation or preservation holding time was exceeded The above sample is reported on a dry weight basis.
64
GENERAL ENGINEERING LABORATORIES, LLC 2040 Savage Road Charleston SC 29407 - (843) 556-8171 - www.gel.com Certificate of Analysis Company:
Connecticut Yankee Atomic Power Address:
362 Injuih Hollow Rd East Hampton, Connecticut 06424
Contact:
Mr. Jack McCarthy Project:
Soils PO# 002332
- Report Date: September 26, 2006 Client Sample ID:
Sample ID:
Matrix:
Collect Date:
Receive Date:
Collector:
Moisture:
- 9530-0004-015F 171454014 TS 25-AUG-06 12-SEP-06 Client 18.5%
Proiect:
YANK01204 Client ID:
YANK001 Vol. Recv.:
Parameter Qualifier Result Uncertainty
- Rad Gamma Spec Analysis Gamna,Solid-FSS GAM & ALL FSS 226 higrowth Waived Actinium-228 0.771
+/-0.213 Americium-241 U
0.131
+/-0.144 Bismuth-212 U
0.357
+/-0.446 Bismuth-214 0.539
+/-0.113 Cesium-134 U
0.0649
+/-0.0596 Cesium-137 U
0.0206
+/-0.0323 Cobalt-60 U 0.000588
+/-0.0319 Europium-152 U
0.00801
+/-0.0822 Euiropium-154 U
0.0179
+/-0.0917 Europium-155 U
0.0146
+/-0.0701 Lead-212
- 0.765
+/-0.0845 Lead-214 0.543
+/-0.116 Manganese-54 U
0.0153
+/-0.0318 Niobium-94 U
-0.0097
+/-0.0264 Potassium-40 12.0
+/-1.25 Radium-226 0.539
+/-0.113 Silver-108m U -0.00849
+/-0.026 Thallium-208 0.241
+/-0.0536 LC TPU MDA Units DF Analyst Date Time Batch Mi 0.0715 0.0925 0.188 0,0438 0.032 0.0296 0.0273 0.0629 0.0808 0.0653 0.0388 0.0525 0.0283 0.0218 0.287 0.0438 0.0209 0.0306
+/-0.213
+/-0.144
+1-0.446
+/-0.113
+/-0.0596
+/-0.0323
+/-0.0319
+/-0.0822
+/-0.0917
+/-0.0701
+/-0.0845
+/-0.116
+/-0.0318
+/-0.0264
+/-1.25
+/-0.113
+/-0.026
+/-0.0536-0.162 0.195 0.413 0,0953 0.0695 0.0636 0.0618 0.134 0.181 0.137 0.0816 0.111 0.0616 0.0477 0.646 0.0953 0.0452 0.0554 pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g MJHI 09/20/060959 569467 The following Prep Methods were performed Method Description Analyst Date Time Prep Batch Dry Soil Prep Dry Soil Prep GL-RAD-A-021 AXP2 09/12/06 1740 567633 The following Analytical Methods were performed Method Description I
EML HASL 300, 4.5.2.3 Notes:
The Qualifiers in this.report are defined as follows A quality control analyte recovery is outside of specified acceptnce criteria Result is less than value reported 65
GENERAL ENGINEERING LABORATORIES, LLC 2040 Savage Road Charleston SC 29407 - (843) 556-8171 - www.gel.com Certificate of Analysis Company:
Connecticut Yankee Atomic Power Address:
362 Injun Hollow Rd East Hampton, Connecticut 06424 Repoi't Date: September 26, 2006
Contact:
Mr. Jack McCarthy Project:
Soils PO# 002332 Client Sample ID:
.9530-0004-015F Project:
YANK01204 Sample ID:
17145 4014 Client ID:
YANK001 e171454014 Vol. Recv.:
Parameter Qualifier Result Uncertainty LC TPU MDA Units DF Analyst Date Time Batch Mt Result is greater than value reported A
The TIC is a suspected aldol-condensation product B
Target analyte was detected in the associated blank BD Results are either below, the MDC or tracer recovery is low C
Analyte has been confirmed by GC/MS analysis D
Results are reported from a diluted aliquot of the sample H
Analytical holding tine was exceeded J
Value is estimated N/A Spike recovery limits do not apply. Sample concentration exceeds spike concentration by 4X or more.
R Sample results are rejected U
Analyte was analyzed for, but not detected above the MDL, MDA, or LOD.
UI Gamma Spectroscopy--Uncertain identification
- X Consult Case Narrative, Data Summary package, or Project Manager concerning this qualifier Y
QC Samples were not spiked with this compound A
RPD of sample and duplicate evaluated using +/-RL. Concentrations are <5X the RL h
Preparation or preservation holding time was exceeded The above sample is reported on a dry weight basis.
66
GENERAL ENGINEERING LABORATORIES, LLC
.2040 Savage Road Charleston SC 29407 - (843) 556-8171 - www.gel.corn Certificate of Analysis Company:
Connecticut Yankee Atomic Power Address:
362 Injun Hollow Rd
ýEast Hampton, Connecticut 06424
Contact:
Mr. Jack McCarthy Project:
Soils PO# 002332 s Report Date: September 26, 2006 Client Sample ID:
Sample ID:
Matrix:
Collect Date:
Receive Date:
Collector:
Moisture:
9530-0004-002F 171454015 TS 25-AUG-06 12-SEP-06 Client 5.87%
Proiect:
YANKO 1204 Client ID:
YANKOOl Vol. Recv.:
Parameter Qualifier Result Uncertainty LC TPU MDA Units DF Analyst Date Time Batch Mt Rad Gamma Spec AnalysiE Ganzlna,Solid-FSS GAM & ALL FSS 226 h.hrowth Waived Actinium-228 0.890
+/-0.198 Americium-241 U
0.111
+/-0.0873 Bismuth-212 0.448
+/-0.402 Bismuth-214 0.451
+/-0.126 Cesium-134 U
0.0322
+/-0.0326 Cesium-137 0.276
+1-0.0672 Cobalt-60 U
0.00116
+/-0.0283 Europium-152 U
0.0676
.+/-0.0983 Europium-154 U -0.00709
+/-0.0877 Europium-155 U
0.0413
+/-0.0724 Lead-212 0.607
+/-0.0888 Lead-214 0.508
+/-0.113 Manganese-54 U
0.0131
+/-0.0253 Niobium-94
-U 0.0257
+/-0.0306 Potassium-40 13.2
+/-1.37 Radium-226 0.451
+/-0.126 Silver-108m U -0.00195
+/-0.0249 Thalliutn-208 0.219 W+-0.0576 o.0688 0.0723 0.173 0.0421 0.0304 0.0233 0.0236 0.0638 0.0721 0.0639 0.0355 0.0433 0.0229 0.0222 0.214 0.0421 0.021 0.0228
+/-0.198
+/-0.0873
+/-0.402
+/-0.126
+/-0.0326
+/-0.0672
+/-0.0283
+/-0.0983
+/-0.0877
+/-0.0724
+/-0.0888
+/-0.113
+/-0.0253
+/-0.0306
+/-1.37
+/-0.126
+/-0.0249
+/-0.0576 0.138 0.144 0.346 0.0841 0.0607 0.0465 0.0471 0.128 0.144 0.128 0.071 0.0865 0.0457 0.0443 0.428 0.0841 0.0419 0.0456 pCi/g pCi/g pCi/g
- pCi/g pCi/g pCi/g pCi/g pCi/g pCilg pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g MJHI. 09/20/06 1015 569467 The following Prep Methods were performed Method Description Analyst Date Time Prep Batch Dry Soil Prep Dry Soil Prep GL-RAD-A-021 AXP2 09/12/06 1740 567633.
The following Analytical Methods were performed Method Description I
EML HASL 300, 4.5.2.3 Notes:
The Qualifiers in this report are defined as follows A quality control analyte recovery is outside of specified acceptance criteria Result is less than value reported 67
GENERAL ENGINEERING LABORATORIES, LLC 2040 Savage Road Charleston SC 29407 - (843) 556-8171 - www.gel.com Certificate of Analysis Company:
Connecticut Yankee Atomic Power Address:
362 Injun Hollow Rd East Hampton, Connecticut 06424.,:
Report Date: September 26, 2006
Contact:
Mr. Jack McCarthy Project:
Soils PO# 002332 Client Sample ID:
9530-0004-002F Project:
YANK01204 Sample ID:
171454015 Client"D:
yANKOO1 Vol. Recv.:
Parameter Qualifier Result Uncertainty LC TPU NVIDA Units DF Analyst Date Time Batch MI Result is greater than value reported A
The TIC is a suspected aldol-condensation product B
Target analyte was detected in the associated blank BD Results are either below the MDC or tracer recovery is low C
Analyte has been confirmed by GC/MS analysis D
Results are reported from a diluted aliquot of the sample H
Analytical holding time was exceeded J
Value is estimated N/A Spike recovery limits do not apply. Sample concentration exceeds spike concentration. by 4X or more R
Sample results are rejected
UT Gamma Spectioscopy-Uncertain identification X
ConsultCase Narrative, Data Summary package, or Project Manager concerning this qualifier Y
QC Samfples were not spiked with this compound A
RPD of sample and duplicate evaluated using +/-RL. Concentrations are <5X the RL h
Preparation or preservation holding time was exceeded The above sample is reported on a dry weight basis.
68
GENERAL ENGINEERING LABORATORIES, LLC
. 2040 Savage Road Charleston SC 29407 - (843) 556-8171 - www.gel.com Certificate of Analysis Company:
Connecticut Yankee Atomic Power Address:
. 362 Injun Hollow Rd East Hampton, Connecticut 06424..
Contact:
1vIh. Jack McCarthy Project:
Soils PO# 002332 Report Date: September 26, 2006 Client Sample ID:
Sample ID:
Matrix:
Collect Date:
Receive Date:
Collector:
Moisture:
9530-0004-OIOF 171454016 TS 25-AUG-06 12-SEP-06 Client 3.68%
Proiect:
Client ID:
Vol. Recv.:
YANKO 1204 YANK001 Parameter Qualifier Result Uncertainty LC TPU MDA Units DF Analyst Date Time Batch Mt Rad Gamma Spec Analysis Galizia,Solid-FSS GAM & ALL FSS 226 Ingrowth Waived Actinium-228 0,605
+1-0.177 0.0583
+/-0.177 0.131 pCi/g MJH1I 09/20/06 1000 569467 Amiericium-241 U
-0.0974
+/-0.107 0.0835
+/-0.107 0.175 pCi/g Bismuth-212 0.630
+/-0.244 0.127
+/-0.244
.0.282 pCi/g Bismuth-214.
0.401
+/-0.0943 0.0355 +/-0.0943 0.0771 pCi/g Cesium-134 U
0.0104
+/-0.0277 0.024 +1-0.0277 0.0523 pCi/g Cesium-137 0.0645
+/-0.0395 0.0221 +/-0.0394 0.0478 pCi/g Cobalt-60 U
-0.0256
. +/-0.023 0.0149
+/-0.023 0.0354 pCi/g Europium-152 U-0.000691
+/-0.0602 0.0535 +/-0.0602 0.114 pCi/g Europium-154 U
-0.0228
+/-0.0758 0.0608 +/-0.0758 0.137
.pCi/g Europium-155 U
0.0761
+/-0.0638 0.0609 +/-0.0638 0.127
. pCilg Lead-212 0.496
+/-0.0625 0.0304 +/-0.0635 0.0641 pCi/g Lead-214 0.413
+/-0.105 0.0356
+/-0.105 0.0762.
pCi/g Manganese-54 U -0.00288
+/-0.0234 0.0202 +/-0.0234 0.0443 pCi/g Niobium-94 U
0.00672
+/-0.0215 0.0187 +/-0.0215 0.0406 pCi/g-Potassium-40 9.33
+!-0.944 0.173
+/-0.944 0.401 pCi/g Radium-226 0.401
+/-0.0943 0.0355 +/-0.0943 0.0771 pCi/g Silver-108m U
-0.0011
+/-0.0193 0.0168 +/-0.0193 0.0363 pCi/g Thallium-208 0.188
+/-0.0533 0.0188 +/-0.0533 0.0409 pCi/g The following Prep Methods were performed Method Description Analyst Date Time Prep Batch Dy Soil Prep Dry Soil Prep GL-RAD-A-021 AXP2 09/12/06 1740 567633 The following Analytical Methods were performed Method Description SEMIL HASL 300, 4.5.2.3
.Notes:
The Qualifiers in this report are defined as follows
.A quality control analyte recovery is outside of specified acceptance criteria Result is less than value reported 69
GENERAL ENGINEERING LABORATORIES, LLC 2040 Savage Road Charleston SC 29407 - (843) 556-8171 - www.gel.com Certificate of Analysis Company:
Connecticut Yankee Atomic Power Address:
362 Injun Hollow Rd East Hampton, Connecticut 06424 Report Date: September 26, 2006
Contact:
Ms. Jack McCarthy Project:
Soils PO# 002332 Client Sample ID:
9530-0004-010F.
Proiect:
YANK 01204 Samplel D:
171454016 Client ID:
YANK001 Vol. Recv.:
Parameter Qualifier Result Uncertainty LC TPU
'MIDA Units DF Analyst Date Time Batch Mt
>. Result is greater than value reported A
The TIC is a suspected aldol-condensation product B
Target analyte was detected in die associated blank BD. Results are either below the MDC or tracer recovery is low C
Analyte has been confirmed by GC/MS analysis D
Results are reparted from a diluted aliquot of the sample H
Analytical holding tine w.as exceeded J
Value is. estimated
- N/A Spike'irecovery limits do not apply.' Sample concentration exceeds spike concentration by 4X or more R
Sample results are rejected U
Analyte was analyzed for, but not detected above the MIDL, MDA, or LOD.
UT Gamma Spectroscopy--Uncertain identification X
Consult' Case Narrative, Data Summary package, or Project Manager concerning this qualifier Y
QC Samples were not spiked with this compound A
RPD of sample and duplicate evaluated using +/--RL. Concentrations are <5X the RL h
Preparation or preservation holding time was exceeded The above sample is reported on a dry weight basis.
70
.GENERAL ENGINEERING LABORATORIES, LLC 2040 Savage Road Charleston SC 29407 - (843) 556-8171 - www.gel.com Certificate of Analysis Company :
Connecticut Yankee Atomic Power Address:
362 Injun Hollow Rd
Contact:
Project:
East Hampton, Connecticut 06424 Mr. Jack McCardhy Soils PO# 002332 Report Date: September 26, 2006 Client Sample ID:
Sample ID:
Matrix:
Collect Date:
Receive Date:
Collector:
9530-0004-008F 171454017 TS 28-AUG-06 12-SEP-06 Client
.Project:
Client ID:
Vol. Recv.:
YANK01204 YANK001 Moisture:
26.2%
Parameter Qualifier Result Uncertainty LC TPU MDA Units DF Analy.t Date Time Batch Mt Rad Gamma Spec Analysis Ganuna,Solid-FSS GAM & ALL FSS 226 Ingrowth Waived Actinium-228 0.765
+/-0.177 0.0461
+/-0.172 0.0975 pCi/g MJHI 09/20/06 1000 569467 Americium-241 U
0.00995
+/-0.135 0.0866
+/-0.135 0.177 pCi/g Bismuth-212 0.632
+/-0.210 0.0969
+/-0.210 0.204 pCi/g Bismuth-214 0.574
+/-0.0905 0.0241 +/-0.0905.
0.0504 pCi/g Cesium-134:
U 0.0329
+/-0.0205 0.0175 +/-0.0205 0.0365 pci/g Cesium-137 0.144
+/-0.0344 0.0154 +/-0.0344 0.032 pCi/g Cobalt-60 U
0.00255
+/-0.0159 0.0135 +/-0.0159 0.0291 pCi/g Europium-152 U
-0.0482
+/-0.040 0.0335
+/-0.040 0.0694 pCi/g Europium-154 U
0.0473
+/-0.0529 0.0474 +/-0.0529 0.100 pCi/g Europium-155 U
0.0687
+/-0.0585 0.0418 +/-0.0585 0.0855 pCi/g Lead-212 0.880
+/-0.086 0.0206
+/-0.086 0.0423 pCi/g" Lead-214 0.708
+/-0.0946 0.0252 +/-0.0946 0.0522 pCi/g.
-0.0109
+/-0.0181 0.013 +/-0.01,81 0.0274 pCi/g Niobium-94 U
0.00688
+/-0.0143 0.013 +/-0.0143 0.0272 pCi/g Potassium-40 12.8
+/-1.08 0.102
+/-1.08 0.224 pCi/g Radium-226 0.574
+/-0.0905 0.0241 +/-0.0905 0.0504 pCi/g Silver-108m U
0.00291
+/-0.0137 0.012 +/-0.0137 0.025 pCi/g Thallium-208 0.279
+/-0.0431 0.013 +/-0.0431 0.0272 pCi/g The following Prep Methods were performed Method Description Analyst Date Time Prep Batch Dry Soil Prep Dry Soil Prep GL-RAD-A-021 AXP2 09/12/06 1740 567633 The following Analytical Methods were performed Method Description 1
EML HASL 30014.5.2.3 Notes:
The Qualifiers in this report are defined as follows A quality control analyte recovery is outside of specified acceptance criteria Result is less than value reported 71
GENERAL ENGINEERING LABORATORIES, LLC 2040 Savage Road Charleston SC 29407 - (843) 556-8171 - www.gel.com Certificate of Analysis Company:
Connecticut Yankee Atomic Power Address 362 Injun Hollow Rd East Hampton, Connecticut 06424 Report Date: September 26, 2006
Contact:
Mr. lack McCarthy Project:
Soils PO# 002332, Client Sample ID:
.9530-0004-008F Project:
YANKO 1204 SampleID:
171454017 Client ID:
YANK001 Vol. Recv.:
Parameter Qualifier Result Uncertainty LC TPU MDA Units DF Analyst Date Time Batch Mtf Result is greater than value reported A
The TIC is a suspected aldol-condensation product
- B Target analyte was detected in the associated blank-BD Results are either below the MDC or tracer recovery is low C
Analyte has been confirmed by GC/MS analysis D
Results.are reported from a diluted aliquot of the sample.
.H Analytical holding time was exceeded J.
Value isl estimated N/A Spikerecovery limits do not apply. Sample concentration exceeds spike concentration by 4X or more R
Sampleiresults are rejected U
Analyte was analyzed for, but not detected above the MDL, MDA, or LOD.
- UT Gamma. Spectroscopy--Uncertain identification X
Consult.Case Narrative, Data Summary package, or Project Manager concerning this qualifier
- .Y QC Satiples were not spiked with this compound A
RPD of sample and duplicate evaluated using +/-RL. Concentrations are <5X the RL h
Preparation or preservation holding time was exceeded The above sample is reported on a dry weight basis.
72
GENERAL ENGINEERING LABORATORIES, LLC 2040 Savage Road Charleston SC 29407 - (843) 556-8171 - www.gel.com Certificate of Analysis Company:
Connecticut Yankee Atomic Power Address:
362 Injun Hollow Rd
'East Hampton, Connecticut 06424
Contact:
Mr. Jack McCarthy Project:
Soils PO# 002332 Report Date:
September 26, 2006 Client Sample ID:
Sample ID:
Matrix:
Collect Date:
Receive Date:
Collector:
Moisture:
- 9530-0004-007F 171454018 TS "28-AUG-06
- 12-SEP-06 Client 36.6%
Project: : YANK01204 Client ID:
YANKOO1 Vol. Recv.:
Parameter Qualifier Result Uncertainty LC TPU MDA Units DF Analyst Date Time Batch Mt Rad Gamma Spec Analysis Gamina,Solid-FSS GAM & ALL FSS 226 Ihgrowth Waived Actinium-228.
0.846
+/-0.200 0.0729
+f-0.2J0.
0.146 pCi/g MJHt 09/20/06 1016 569467 Americium-241 U
-0.0396
+/-0.0954 0.0833 +/-0.095z:.
0.167 pCi/g SBisnu-212 0.585
+/-0.371 0.158
+/-0.371 0.316 pCi/g Bismuth-214:
0.626
+/-0.103 0.0384
+/-0.!03 0.0767 pCi/g Cesium-134 U
0.0462
+/-0.0283 0.0251 +/-0,0283 0.0502 pCi/g Cesium-137 0.353
+/-0.051 0.0192
+/-0.051 0.0384 pCi/g Cobalt-60 U
-0.0191
+/-0.0295 0.0205 +/-0.0295 0.0409 pCi/g" Europium-152 U 0.000947
+/-0.062; 0.655 +/-0.0631 0.110 pCi/g Europium-154 U -0.00356
+/-0.077 0.0644
+/-0.077 0.129 pCi/g Europium-155 U
0.034
+/-0.0692 0.0592 +/-0.0692 0.118 pCi/g
- Lead-212 0.868
+/-0.101 0.0305
+/-0.t01 0.061 pCi/g Lead-214 0.675
+/-0.0989 0.0397 +/-0.0989 0.0793.
pCi/g Manganese-54 U
0.0216
+/-0'0239 0.0221 +/-0.0239 0.0441 pCi/g Niobium-94 U
0.0126
+/-0.0227 0.0198 +/-0.0227 0.0395 pCi/g Potassium-40 12.8
+1-1.19 0.154
+/-1.19 0.309 pCi/g Radium-226 0.626
+/-0.103 0.0384
+/-0.103 0.0767 pCi/g Silver-108m U
0.0121
+/-0.022 0.0195
+/-0.022 0.039 pCi/g Thallium-208 0.297
+/-0.0497
.0.0194 +/-0.0497 0.0387 pCi/g The following Prep Methods were performed Method Description Analyst Date Time Prep Batch Dry Soil Prep Dry Soil Prep GL-RAD-A-021 AXP2 09/12/06
. 1740 567633 The following Analytical Methods were performed Method Description 1
EMI HASL 300, 4.5.2.3 Notes:
The Qualifiers in this report are defined as follows A quality control analyte recovery is outside of specified acceptance criteria Result is less thal value reported 73
GENERAL ENGINEERING LABORATORIES, LLC 2040 Savage Road Charleston SC 29407 - (843) 556-8171 - www.gel.com Certificate of Analysis Company Connecticut Yankee Atomic Power Address:
362 Injun Hollow Rd East Hampton, Connecticut 06424 Report Date: September 26, 2006
Contact:
Mr. Jack McCarthy
- Project:
Soils PO# 002332 Client Sample ID:
9530-0004-007F Proiect:
YANK01204 Sample ID:
.171454018 Client ID:
YANK001 Vol. Recv.:
Parameter Qualifier Result Uncertainty LC TPU MDA Units DF Analyst Date Time Batch M1 Result is greater than value reported A
The TIC is a suspected aldol-condensation product B
Target analyte was detected in the associated blank BD Results are either below the MDC or tracer recovery is low
- C Analyte has been confirmed by GC/MS analysis D
Results are reported from a diluted aliquot of the sample H
Analytical holding tine was exceeded J
Value is estimated N/A Spike recovery limits do not apply. Sample concentration exceeds spike concentration by 4X or more Sample results are rejected U
Analyte was analyzed for, but not detected above the MDL, MDA, or LOD.
UI Gamma Spectroscopy-Uncertain identification X
Consult Case Narrative, Data Summary package, or Project Manager concerning this qualifier Y
QC Samples were not spiked with this compound A
RPD of sample and duplicate evaluated using +/-RL. Concentrations are <5X the RL 11 Preparation or preservation holding time was exceeded The above sample is reported on a dry weight basis.
74
GENERAL. ENGINEERING LABORATORIES, LLC 2040 Savage Road Charleston SC 29407 - (8343) 556-8171 - www.gal.com Certificate of Analysis Company:
Connecticut Yankee Atomic Power Address:
362 Injun Hollow Rd
Contact:
Project:
- East Hampton, Connecticut 06424 Mr. Jack McCarthy Soils PO# 002332
.Report Date: September 26, 2006 Client Sample ID:
Sample ID:
Matrix:
- .Collect Date:
Receive Date:
Collector:
9530-0004-005F 171454019 TS 28-AUG-06 12-SEP-06 Client Project:
Client ID:
Vol. Recv.:
YANK01204 YAN-KOOI IvIuisture:
1U0.4o Parameter Qualifier Result Uncertainty LC TPU ADA Units DF Analyst Date Time Batch Mt Rad Gamma Spec Analysis Gaoinia.,Solid-FSS GAM & ALL FSS 226 Ingrowth Waived Actinium-228 0.548
+/-0.247 0.104
+/-0.247 0.225 pCi/g MJH1 09/20/06 1001 569467 Americium-241 U
0.00343
+/-0.0421 0.0376 +/-0.0421 0.078 pCi/g Bismuth-212 U
0.423
+/-0.488 0.214
+/-0.488 0.460 pCi/g Bismuth-214 0.544
+/-0.137 0.0473
+/-0.137 0.102 pCiag Cesium-134 "U
.0.0373
+/-0.0393 0.0358 +/-0.0393 0.0765 pCi/g Cesium-137 0.199
+/-0.0648 0.0261 +/-0.0648 0.0563
.pCi/g Cobalt-60 U
0.0171
+/-0.0295 0.0269 +/-0.0295 0.0599.
pCilg:
Europium-152 U
-0,028
+/-0.0891 0.0655 +/-0.0891 0.139 pCilg Europium-154 U
0.131
+/-0.102 0.0982
+/-0.10 2 0.213 pCi/g Europium-155 U
0.045
+/-0.085 0.058
+/-0.085 0.121 pCi/g Lead-212 0.637
+/-0.0767, 0.0392 +/-0.0767 0.0818 pCi/g.
Lead-2t4 0.638
+/-0.125 0.0489
+/-0.125 0.103 pCi/g Manganese-54 U
0.0337.
+/-0.03t'.:i 0.0317 +/-0.0348 0.0679 pCi/g Niobium-94 U
0.0338.
+/-0.0313 0.029 +/-0.0313 0.0617 pCi/g Potassium-40
.. 11.8
+/-1.12 0.192
+/-1.12 0.445 pCi/g.
Radium-226 0.544
+/-0.137 0.0473
+/-0.137 0.102 pCi/g Silver-108m U
-0.024
+/-0.0254 0.0211 +1-0.0254 0,0452 pCi/g Thallium-208 0.238
+/-0.0663 0.0246 +/-0.0663 0.053 pCi/g The following Prep Methods were performed Method Description Analyst Date Time Prep Batch Dry Soil Prep Dry Soil Prep GL-RAD-A-021 AXP2 09/12/06 1740 567633 The following Analyticai Methods were performed Method Description I
EML HASL 300, 4.5.2.3 Notes:
The Qualifiers in this report are defined as follows:
A quality control analyte recovery is outside of specified acceptance criteria RestLdt is less than value reported 75
GENERAL ENGINEERING LABORATORIES, LLC 2040 Savage Road Charleston SC 29407 - (843) 556-8171 - www.gel.com Certificate of Analysis Company:
Connecticut Yankee Atomic Power Address:
362 Injun Hollow Rd East Hampton, Connecticut 06424 Report Date: Septcmbcr 26, 2006
Contact:
Mr. Jack McCarthy Project:
Soils PO# 002332 Client Sample ID:
9530-0004-005F Project:
YANK01204 Sample ID:
171454019 Client ID:
YANK001
.Vol. Recv.:
Parameter Qualifier Result Uncertainty LC TPU MIDA Units DF Analyst Date Time Batch Mt.
Result is greater than value reported A
The TIC is a suspected aldol-condensation product B
Target analyte was detected in the associated blank BD Results are either below the MDC or tracer recovery is low C
Analyte has been confirmed by GC/MS analysis D
Results are reported from a diluted aliquot of the sample H
Analytical holding time was exceeded J
Value is estimated N/A Spike recovery limits do not apply. Sample concentration exceeds spike concentration by 4X or more R
- Sample results are rejected U
Analyte was analyzed for, but not detected above the IDL, MDA, or LOD.
UI Gamma Spectroscgpy--Uncertainr identification
- X Consult Case Narrative, Data Summary package, or Project Managerconcerning this qualifier Y
QC Samples were not spiked with this compound A
RPD of sample and duplicate evaluated using +I-RL. Concentrations are <5X the RL li Preparation or preservation holding time was exceeded The above sample is reported on a dry weight basis.
76
.GENERAL ENGINEERING LABORATORIES, LLC 2040 Savage Road Ctharleston SC 29407 - (843) 556-8171 - www.gel.com Certificate of Analysis Company:
Connecticut Yankee Atomic Power Address:
362 Injun Hollow Rd East Hampton, Connecticut 06424
Contact:
Mi-. Jack McCarthy Project:
Soils PO# 002332
- Client Sample ID:
Sample ID:
Matrix:
Collect Date:
Receive Date:
Collector:
Moisture:
Report Date: September 26, 2006 Project:
YANK01204 Client ID:
YANK001 Vol. Recv.:
9530-0004-020F 171454020 TS 06-SEP-06 12-SEP-06 Client 4.14%
Parameter Qualifier Result U,
Rad Gamma Spec Analysis Gammna,Solid-FSS GAM & ALL FSS 226 Ingrowth Waived Actinium-228.
0.990
- Americium-241 U -0.00407 Bismuth-212 0.842
.Bismuth-214 0.566
+
Cesium-134 UI 0.00 Cesium-137 U -0.00736 4
-0.0279
+
Europium-152 U
0.00643
+
Europium-154 U
0.00909 Europium-155 Ut 0.00
-+
Lead-212 0.878 4
Lead-214 0.514 Manganese-54 U
0.0197 4
Niobium-94 U
0.00189 Potassium-40 15.1 Radium-226 0.566
-+
Silver-108m U -0.00561
-1 Thallium-208 0.284 ieertainty LC TPU lM'DA Units DF Analyst Date Time Batch Mt
+/-0.192 k/-0.0306
+/-0.305
-/-0.0869
+/-0.041 4/-0.0229
-/-0.0241
/-0.0545 4!-0.0838
/-0.0823 4/-0.0665 4/-0.0885
-/-0.0264 4-/-0.0209
+/-1.11
/--0.0869
-/-0.0183
+/-0.049 0.0712 0.0275 0.157 0.0366 0.0284 0.0191 0.0162 0.0474 0.0719 0.0429 0.0277 0.034 0.0238 0.0181 0.208 0.0366 0.0161 0.0181
+/-0.192
+/-0.0306
+/-0.305
+/-0.0869
+/-0.041
+/-0.0229
+/-0.0241
+/-0.0545
+/-0.0838
+/-0.0823
+/-0.0665
+/-0.0885
+/-0.0264
+/-0.0209
+4-1.11
+/-0.0869
+/-0.0183
+/-0.049 0.156 0.0569 0.339 0.0787 0.0606 0.0415 0.0376 0.101 0.158 0.0893 0.0581 0.0722 0.0512 0.039 0.467 0.0787 0.0345 0.0392 pCi/g pCiig
.pCi/g
..pCi/g
.pCi/g
..pCi/g pCi/g pCilg
" pCi/g pCi/g pCi/g pCi/g pCi/g
- .pCi/g pCi/g pCi/g pCi/g
- pCi/g MJI-11 09/20/06 1001 569467 The following Prep Methods were performed Method Description Analyst Date Time Prep Batch Dry Soil Prep Dry Soil Prep GL-RAD-A-021 AXP2 09/12/06 1740 567633 The following Analytical Methods were performed Method Description 1
EML HASL 300, 4.5.2.3 Notes:
The Qualifiers in this report are defined as follows A quality contiol analyte recovery is outside of specified acceptance criteria Result is less thnm value reported -
77
GENERAL ENGINEERING LABORATORIES, LLC 2040 Savage Road Charleston SC 29407 - (843) 556-8171 - www.gel.com Certificate of Analysis Company Conneclicut Yankee Atomic Power Address:
362 Injun Hollow Rd East Hampton, Connecticut 06424 Report Date: September 26, 2006
Contact:
Mr. Jack McCarthy Project:
Soils PO# 002332 Client Sample ID:
9530-0004-020F Proiect:
YANK01204 Sample ID:
171454020 Client ID:
YANK001 Vol. Recv.:
Parameter Qualifier Result Uncertainty LC TPU MVlDA Units DF Analyst Date Time Batch Mt Result is greater than value reported A
The TIC is a suspected aldol-condensation product B
Target analyte was detected in the associated blank BD Results are either below the MDC or tracer recovery is low
- C Analyte has been confirmed by GC/MS analysis D
Results are reported from a diluted aliquot of the sample H
Analytical holding time was exceeded
.J Value islestimated
- N/A Spike recovery limits do not apply. Sample concentration exceeds spike concentration by 4X or more R
Sample results are rejected U
Analyte was,analyzed for, but not detected above the MDL, MDA, or LOD.
IUI Gamma Spectroscopy--Uncertain identification X
Consult Case Narrative, Data Sunmmary package, or Project Manager concerning this qualifier Y
QC'Samples were not spiked with this compound A
RPD of sample and duplicate evaluated using +/-RL. Concentrations are <5X the RL It Preparation or preservation holding time was exceeded The above sample is reported on a dry Weight basis.
78
GENERAL ENGINEERING LABORATORIES, LLC 2040 Savage Road Charleston SC 29407 - (843) 556-8171 - www.gel.com Certificate of Analysis Company:
Connecticut Yankee Atomic Power Address:
362 hijun Hollow Rd East Hampton, Connecticut 06424
Contact:
Mr. Jack McCarthy Project:
Soils PO# 002332 Report Date: September 26, 2006 Client Sample ID:
9530-0004-021F Proiect:
YANK01204 Sample ID:
171454021 ClientID:
YANK001 Matrix:
TS Vol. Recv.:
Collect Date:
06-SEP-06 Receive Date:
12-SEP-06 Collector:
Client Moisture:
8.77%
Parameter Qualifier Result Uncertainty LC TPU MDA Units DF Analyst Date Time Batch MI Rad Gamma Spec Analysis Ganvma,Solid-FSS GAM & ALL FSS 226 Ingrowth Waived Actinium-228 0.966
+/-0.205 0.0841
+/-0.205 0.186 pCi/g MJHI 09/20/06 1010 569468 Americium-241 U
0.0256
+/-0.0283 0.034 +/-0.0283 0.0705 pCi/g'
- Bismuth-212
.0.535
+/-0.397 0.194
+/-0.397 0.422 pCi/g Bismuth-214 0.783
+/-0.136 0.0473
+/-0.136 0.102 pCi/g Cesium-I 34 U
0.0136
+/-0.049 0.0312
+/-0.049 0.0674 pCi/g Cesiun-137 U
0.00736
+J-0.031.5 0.0271
+/-0.0315 0.0584 pCi/g
.Cobalt-60 U
-0.0106
+/-0.0307 0.0242 +/-0.0307 0.055 pCi/g
- Europium-152
-J -0.0362
+/-0.0681 0.058 +/-0.0681 0.124 pCi/g Europiuln-154 U
-0.0783
+/-0.125 0.0796
+/-0.125 0.171 pCi/g Etuopium-155 U
0.0611
+/-0.0653 0.0609 +/-0.0653 0.127 pCi'g Lead-212 0.866
+/-0.084 0.0357
+/-0.084 0.0749 pCi/g Lead-214 0.680
+/-0.118 0.0442
+/-0.118 0.0939 pCi/g Manganese-54 U
0.0469
+/-0.043 0.026
+/-0.043 0.0566 pCi/g Niobium-94 U -0.00108
+/-0.0287 0.024 +/-0.0287 0.0517 pCi/g Potassium-40 14.8
+/-1.27 0.216
+/-1.27 0.499 pCi/g Radium-226 0.783
+/-0.136 0.0473
+/-0.136 0.102 pCi/g Silver-108m U
0.0177
+/-0.0238 0.022 +/-0.0238 0.047 pCi/g Thallium-208 0.316
+/-0.0603 0.0234 +/-0.0603 0.0507 pCi/g The following Prep Methods were performed Method Description Analyst Date Time Prep Batch Dry Soil Prep Dry Soil Prep GL-RAD-A-021 AXP2 09/12/06 1713 567634 The following Analytical.Methods were performed
-- Li~tthbd...--.
Description----------
EML HASL 300, 4.5.2.3 Notes:
The Qualifiers in this report are defined as follows A quality control analyte recovery is outside of specified acceptance criteria Result is less than value reported 79
GENERAL ENGINEERING LABORATORIES, LLC
.2040 Savage Road Charleston SC 29407 - (843) 556-8171 - www.gel.com Certificate of Analysis Company:
Connecticut Yankee Atomic Power Address:
362 Injun Hollow Rd East Hampton, Connecticut 06424 Report Date: Septembe" 26, 2006 Contact; Mr. Jack McCarthy Project:
Soils P6# 002332 Client Sample ID:
9530-0004-021F Project:
YANK01204 Sample ID:
171454021 Client ID:
YANK001 Vol. Recv.:
Parameter Qualifier Result Uncertainty LC TPU i\\I)A Units DF Analyst Date Time Batch Mt Result is greater than value reported
- A The TIC is a suspected aldol-condensation product B
Target analyte was detected in the associated blank BD. Results are either below the MDC or tracer recovery is low.
C Analyte has been confinned by GC/MS analysis D
Results are reported from a diluted aliquot of the sample H
Analytical holding time was exceeded J
Value is estimated N/A Spike recovery limits do not apply. Sample concentration exceeds spike concentration by 4X or more R. Sample results are rejected U
Analyte was analyzed for, but not detected above the MDL, MDA, or LOD.
UI Gamma Spectroscopy--Uncertain identification X
Consult Case Narrative, Data Summary package, or Project Manager concerning this qualifier Y
QC Samples were not spiked with this compound A
RPD of sample and duplicate evaluated using +/-RL. Concentrations are <5X the RL h
Preparation or preservation holding time was exceeded The above sample is reported on a dry weight basis.
80
GENERAL ENGINEERING LABORATORIES, LLC 2040 Savage Road Charleston SC 29407 - (843) 556-8171 - www.gel.com Certificate of Analysis Company Connecticut Yankee Atomic Power Address :
362 Injun Hollow Rd East Hampton, Connecticut 06424'
Contact:
Mr. Jack McCarthy Project:
Soils PO# 002332 Report Date:
September 26, 2006 Client Sample ID,:
Sample ID:
Matrix:.
Collect.Date:
Receive Date:
Collector:
Moisture:
9530-0004-022F
- 1.71454022 TS 06-SEP-06 12-SEP-06 Client 7.69%
Project:
YANKO1204 Client ID:
YANK00I Vol. Recv.:
Parameter Qualifier Result Uncertainty LC TPU MIDA Units DF Analyst Date Time Batch MI Rad Gamma Spec Analysis Ganna, Solid-FSS GAM & ALL FSS 226 lngrowth Waived Actinium-228 0.679
+/-0.115 0.0429
+/-0.115 0.0923 pCi/g MJHI 09/20/06 1056 569468 Americium-241 U
-0.0588
+/-0.0964 0.0777 +/-0.0964 0.161 pCi/g Bismuth-212
.0.418
+/-0.169 0.104
+/-0.169.
0.220 pCi/g Bismuth-214 0.495
+/-0.0633 0.0236 +/-0.0633 0.0498 pCi/g.
Cesium-134 U
0.0355
+/-0.0227 0.0175 +/-0.0227 0.0369 pCi/g Cesium-137 0.0522
+/-0.0292 0.0131 +/-0.0292 0.0277 pCi/g Cobalt-60 U
0.018
+/-0.0138 0.0145 +/-0.0138 0.0316 pCi/g Europium-152 U
-0.0118
+/-0.0409 0.035 +/-0.0409 0.0729 pCi/g Europium-154 U
0.0339
+/-0.0443 0.0499 +/-0.0443 0.107 pCi/g Europium-t55 U
0.0842
+/-0.0521 0.0452 +/-0.0521 0.0929 pCi/g Lead-212 0.786
+/-0.0479 0.0226 +/-0.0479 0.0465
. pCi/g Lead-214 0.611
+/-0.060 0.0211
+/-0.060 0.0445 pCi/g Manganese-54 U -0.00196
+/-0.0164 0.0138 +/-0.0164 0.0293 pCi/g Niobium-94 U
0.0065
+/-0.0152 0.0136 +/-0.0152 0.0286 pCi/g.
Potassium-40 13.7
+/-0.731 0.128
+/-0.731 0.280 pCi/g Radium-226 0.495
+/-0.0633 0.0236 +/-0.0633 0.0498 pCi/g Silver-108m U
0.00245
+/-0.0128 0.0118 +/-0.0128 0.0248 pCi/g Thallium-208 0.242
+/-0.0392 0.0122 +/-0.0392 0.0258 pCi/g The following Prep Methods were performed Method Description Analyst Date Time Prep Batch Dry Soil Prep Dry Soil P,.ep GL-RAD-A-021 AXP2 09/12/06 1713 567634 The following Analytical Methods were performed
--M ethod ---
Description EML HASL"300, 4.5.2.3 Notes:
The Qualifiers in this report are defined as follows A quality control analyte recovery is outside of specified acceptance criteria Result is less than value reported 81
GENERAL: ENGINEERING LABORATORIES, LLC 2040 Savage Road Charleston SC 29407 - (843) 556-8171 - Www.gel.com Certificate of Analysis Company:
Connecticut Yankee Atomic Power Address:
362 Injun Hollow Rd East Hampton, Connecticut 06424 Report Date: September 26, 2006
Contact:
Mr. Jack McCarthy Project:
Soils PO# 002332 Client Sample ID:
9530-0004-022F Project:
YANKO 1204 Sample ID:
171454022 Client ID:
YANK001 Vol. Recv.:
Parameter Qualifier Result Uncertainty LC TPU M2DA Units DF Analyst Date Time Batch Mt Result is greater than value reported A
The TIC is a suspected aldol-condensation product B
Target analyte was detected in the associated blank BD Results are either below the MDC or tracer recovery is low C
Analyte has been ccnfirmed by GC/MS analysis
.D Results are reported from a diluted aliquot of the sample
.H.
Analytical holding time was exceeded J Value is estimated
- N/A Spike recovery limits do not apply. Sample concentration exceeds spike concentration by 4X or more
'R Sample results are rejected
.1UI Gamma Spectroscopy--Uncertain identification
.X. Consult Case Narrative, Data Summary package;-or Prpj,-t Manager concerning this qualifier Y
QC Samples were not spiked with this compound A
RPD of sample and duplicate evaluated using +/-RL. Concentrations are <5X the RL h
Preparation or preservation holding time was exceeded The above sample is reported on a dry weight basis..
82
GENERAL ENGINEERING LABORATORIES, LLC 2040 Savage Road Charleston SC 29407 - (843) 556-8171 - www.gel.com Certificate of Analysis Company:
Connecticut Yankee Atomic Power Address:
362 Injun Hollow Rd East Hampton, Connecticut 06424
Contact:
Mr. Jack McCarthy Project:
Soils PO# 002332 Report Date: September 26, 2006 Client Sample ID:
Sample ID:
Matrix:
Collect Date:
Receive Date:
Collector:
Moisture:
953"-0004-023F
]7i454023 TS 06-SEP-06 12-SEP-06 Client 5.66%
.Project:
YANK01204 Client ID:
YANK001 Vol. Recv.:
Parameter Qualifier Result Uncertainty LC TPU MDA Units DF Analyst Date Time Batch MI Rad Gamma Spec Analysis Gamona,Sold-FSS GAM & ALL FSS 226 Ingrowth Waived Actinium-228 0.749
+/-0.176 0.0624
+/-0.176 0.138 pCi/g MJH1 09/20/06 1056 569468 Americium-241 U -0.0538
+/-0.102 0.087
+/-0.102 0.181 pCi/g Bismuth-212 0.542
+/-0.296 0.163
+/-0.296 0.351 pCi/g Bismuth-214 0.504
+/-0.0933 0.0338 +/-0.0933 0.0731 pCi/g
- Cesium-134 U
0.0448
+/-0.0345 0.0259 +/-0.0345 0.0557 pCilg Cesium-137 U
0.026
+/-0.0241 0.0212 +/-0.0241 0.0456 pCi/g.
Cobalt-60 U -0.00303
+/-0.0223 0.0187 +/-0.0223 0.0424
.pCi/g Europium-152 U
-0.0121
+/-0.0529 0.0481 +/-0.0529 0.103 pCi/g Europium-154 U
-0.0253
+1-0.0789 0.0652 +/-0.0789 0.144 pCi/g
- Europium-155 U
0.0206
+/-0.0609 0.0584 +/-0.0609 0.121 pCi/g Lead-212 0.687
+/-0.0668 0.0301 +/-0.0668 0.0631 pCi/g Lead-214 0.656
+/-0.0861 0.0376 +/-0.0861 0.0797 pCi/g Manganese-54 U
0.0201
+/-0.0221 0.0207 +/-0.0221 0.0449 pCi/g Niobium-94 U -0.00284
+/-0.0204 0.0174 +/-0.0204 0.0377
.. pCi/g Potassium-40
.14.1
+/-1.05 0.125
+/-1.05 0.301 pCi/g Radium-226 0.504
+/-0.0933 0.0338 +/-0.0933 0.0731 pCi/g Silver-108m U 0.000829
+/-0.0193 0.0176 +/-0.0193 0.0375 pCi/g Thallium-208 0.247
+/-0.0447 0.0146 +/-0.0447 0.0322 pCi/g The following Prep Methods were performed Method Description Analyst Date Time Prep Batch Dry Soil Prep Dry Soil Prep GL-RAD-A-021 AXP2
.09/12/06 1713 567634 The following Analytical Methods were performed Method Description EML HASL.300, 4.5.2.3 Notes:
The Qualifiers in this report are defined as follows A quality control analyte recovery is outside of specified acceptance criteria Result is less than value reported 83
GENERAL ENGINEERING LABORATORIES, LLC 2040 Savage Road Charleston SC 29407 - (843) 556-8171 - www.gel.com Certificate of Analysis Company:
Connecticut Yankee Atomic Power Address:
362 Injun Hollow Rd East Hampton, Connecticut,06424 Report Date: September 26, 2006,
Contact:
Mr. Jack McCarthy Project:
Soils PO# 002332 Client Sample ID:
9530-0004-023F Proiect:
YANK01204
- Sample ID:
171454023 Client ID:
YANKOO1 Vol. Recv.:
Parameter Qualifier Result Uncertainty LC TPU MDA Units DF Analyst Date Time Batch Mt Result is greater than value reported A
The TIC is a suspected aldol-condensation product B
Target analyte was detected in the associated blank BD Results are either below the MDC or tracer recovery is low C
Analyte has been confirmed by. GC/MS analysis
.D Results are reported from a diluted aliquot of the sample H
Analytical holding time was exceeded J
Value is estimated N/A Spike recovery limits do not apply. Sample concentration exceeds spike concentration by 4X or more
..R Sample results are rejected U
Analyte was analyS..d for, but not detected above the MDL, MDA, or LOD.
- L Gamnia Spectroscopy--Uncertain identification X
Consult Case Narrative, Data Summary package, or Project Manager,.zoncerning this qualifier Y ::.QC Samples were not spiked with-this compound A
RPD of sample and duplicate evaluated using +/-RL. Concentrations abe <5X dte RE h
Preparation or preservation holding time was exceeded.
The above sample is reported on a dry weight basis.
84
GENERAL ENGINEERING LABORATORIES, LLC 2040 Savage Road Charleston SC 29407 - (843) 556-8171 - www.gel.com (Certifia9teof Analysis I
Company:
Connecticut Yankee Atomic Power Address :
362 Injun Hollow Rd East Hampton, Connecticut 06424
Contact:
Mr. Jack McCarthy Project:
Sbils PO# 002332 Report*Date:
September.26, 2006 Client Sample ID:
Sample mD:
Matrix:
Collect Date:
Receive Date:
Collector:
9530-0004--024F 171454024 TS 06-SEP-06 12-SEP-06 Client Project:
YANKO1204 Client ID:
YANK001 Vol. Recv.:
oilSture:
9.7/-/j Parameter Qualifier Result Uncertainty LC TPU lIDA Units DF Analyst Date
-Time Batch MIN Rad Gamma Spec Analysis Gamoza,Solid-FSS GAM & ALL FSS 226 Ingrowth Waived Actinium-228 0.670
+/-0.118 0.0512
+/-0.118 0.109 pCiig MJH1 09/20/06 1057 569468 Americium-241 Ui 0.0803
+/-0.0798 0.0694 +/-0.0798 0.142 pCi/g.
Bismuth-212 0.494
+/-0.221 0.115
+/-0.221 0.243 pCi/g.
- Bismuth-214 0.572
+/-0.0706 0.0285 +/-0.0706 0.0598 pCi/g Cesium-134 Ut 0.00
+/-0.0341 0.0199 +/-0.0341 0.0418 pCi/g
.Cesium-137 0.049
+/-0.0304 0.0159 +/-0.0304 0.0336 pCi/g Cobalt-60.
U 0.00553
+/-0.0184 0.0158 +/-0.0184 0.0342 pCi/g Euiopium-152 U
-0.0199
+/-0.0549 0.0405 +/-0.0549 0.0842 pCi/g.
Europium-154 U
0.0442
+/-0.0541 0.0486 +/-0.0541 0.104 pCi/g Europium-I155 U
0.0247
+/-0.0508 0.0477 +/-0.0508 0.0978 pCi/g
- Lead-212 0.687
+/-0.0494 0.0286 +/-0.0494 0.0587 pCi/g.
Lead-214 0.630
+/-0.0725 0.0294 +/-0.0725 0.0612 pCi/g Manganese-54 U
-0.0082
+/-0.0177 0.0147 +/-0.0177 0.0312 pCi/g Niobium-94 U
0.0136
+/-0.0162 0.0149 +/-0.0162 0.0313 pCi/g Potassium-40 14.0
+/-0.793 0.111
+/-0.793 0.248 pCi/g Radium-226 0.572
+/-0.0706 0.0285 +/-0.0706 0.0598 pCi/g Silver-108m U
-0.005
+/-0.0186 0.0135 +/-0.0186 0.0283 pCi/g Thallium-208 0.254
+/-0.0383 0.0143 +/-0.0383 0.0301 pCi/g The following Prep Methods were performed Method.
Description Analyst Date Time Prep Batch Dry Soil Prep Diy Soil Prep GL-RAD-A-021 AXP2 09/12106 1713 567634 The following Analytical Methods were performed Method Description 1
EML HASL 300, 4.5.2.3 Notes:
The Qualifiers in this report are defined as follows A quality control ar:alyte recovery, is outside of specified acceptance criteria Result is less than value reported 85
GENERAL ENGINEERING LABORATORIES, LLC 2040 Savage Road Charleston SC 29407 - (843) 556-8171 - www.gel.com Certificate of Analysis Company Connecticut Yankee Atomic Power Address:
362 Injun Hollow Rd East Hamptonh Connecticut 06424 Report Date: September 26, 2006
Contact:
Mr. Jack McCarthy Project:
Soils PO# 002332 Client Sample ID:
"9530-0004-024F Project:
YANK01204 Sample ID:
171454024 Client ID:
YANJK10o1 Vol. Recv.:
Parameter Qualifier Result Uncertainty LC TPU MDA Units DF Analyst Date Time Batch MI Result is greater than vadue reported A
The TIC is a suspected aldol-condensation product B
Target analyte was detected in the associated bla.nk BD Results are either below the MDC or tracer recovery is low C
Analyte has been confirmed by GC/MS analysis D
Results are reported from a diluted aliquot of the sample H
- Analytical holding time was exceeded
.J Value is estimated
'N/A Spike recovery limits do not apply. Sample concentration exceeds spike concentration by 4X or more
.R Sampleresults are rejected U
UI Gamma Spectroscopy--Uncertain identification
- X Consult Case Narrative, Data Summary package, or Project Manager concerning this qualifier Y
QC Samples were not spiked with this compound A
RPD of sample and duplicate evaluated using +/-RL. Concentrations are <5X the RL h
Preparation or preservation holding time was exceeded The above sample is reported on a dry weight basis.
86
GENERAL ENGINEERING LABORATORIES, LLC
.2040 Savage Road Charleston SC 29407 - (843) 556-8171 - www.gel.com Certificate of Analysis Company Connecticut Yankee Atomic Power Address 362 Injun Hollow Rd East Hampton, Connecticut 06424
Contact:
Mr. Jack McCarthy Project:
Soils P0# 002332 Report Date:. September 26, 2006 Client Sample ID:
Sample ED:
Matrix:
Collect Date:
Receive Date:
Collector:
Moisture:
9530-0004-025F 171454025 TS 06-SEP-06 12-SEP-06 Client 8.56%
Project:
YANK01204
- ClientID:
YANK001 Vol. Recv.:
Parameter Qualifier Result Uncertainty LC TPU MDA Units DF Analyst Date Time Batch Mt Rad Gamma Spec Analysis Gaojua, Solid-FSS GAM & ALL FSS 226 Ingro-wth Waived Actinium-228 0.917
+/-0.201 0.0584
+/-0.201 0.129 pCi/g MJHI1 09/20/06 1057 569468 Americium-241 U
0.0399
+/-0.0544 0.0515 +/-0.0544 0.107 pCi/g Bismuth-212 U
0.0646
+/-0.280 0.126
+/-0.280 0.276 pCi/g
.Bismuth-214 0.545
+/-0.108 0.0351
+/-0.108 0.0754 pCi/g Cesium-134 U
0.0346
+/-0.0448 0.0259 +/-0.0448 0.0554 pCi/g Cesium-137 U
0.0204
+/-0.0228 0.0217 +/-0.0228 0.0464 pCig.
Cobalt-60 U -0.00485
+,-0.0206 0.0163 +/-0.0206 0.0372 pCi/g Europium-152 U
0.0381
+/-0.0534 0.0497 +/-0.0534 0.105 pCi/g Europium-154 U
0.0369
+/-0.0721 0.0638 +/-0.0721 0.140 pCi/g Europium-155 U
0.00414
+/-0.0562 0.0497 +/-0.0562 0.104 pCi/g Lead-212 0.689
+/-0.0963 0.0391 +/-0.0963 0.0809 pCi/g Lead-214 0.604
+/-0.103 0.0366
+/-0.103 0.0773 pCi/g Manganese-54 U
-0.0148
+/-0.0219 0.0178 +/-0.0219 0.0388 pCi/g Niobium-94 U
0.0153
+/-0.0238 0.0173 +/-0.0238 0.0372 pCi/g Potassium-40 13.3
+/-1.33 0.146
+/-1.33 0.338
. pCi/g Radium-226 0.545
+/-0.108 0.0351
+/-0.108 0.0754 pCi/g Silver-108m U
0.0103
+/-0.0186 0.0169 +/-0.0186 0.036 pCi/g Thallium-208 0.254
+/-0.0559 0.0156 +/-0.0559 0.0339 pCi/g The following Prep Methods were performed Method Description Analyst Date Time Prep Batch Dry Soil Prep Dry Soil Prep GL-RAD-A-021 AXP2 09/12/06 1713 567634 The following Analytical Methods were performed Method Description EML HASL 300, 4.5.2.3 Notes:
The Qualifiers in this report are defined as follows A quality control analyte recovery is outside of specified acceptance criteria Result is less than value reported 87
GENERAL ENGINEERING LABORATORIES, LLC 2040 Savage Road Charleston SC 29407 -. (843) 556-8171 - www.gel.corn Certificate of Analysis Company:
Connecticut Yankee Atomic Power Address:
362 Injun Hollow Rd East Hampton.,.Connecticut 06424 Report Date: September 26, 2006
Contact:
Mr. Jack McCarthy Project:
Soils PO# 002332 Client Sample ID:
9530-0004-025F Proiect:
YANKO1204 Sample ID:
171454025 Client ID:
YANK001 Vol. Recv.:
Parameter Qualifier Result Uncertainty LC TPU MBDA Units DF Analyst Date Time Batch Mt Result is greater than value reported A
The TIC is a suspected aldol-coridensation product B
Target analyte was detected in the associated blank BD Results are either below the MDC or tracer recovery -s low C
Analyte has been confirmed by GC/MS analysis D
Results are reported from a diluted aliquot of the sample H
Analytical holding time was exceeded J
Value is estimated N/A Spike recovery limits do not apply. Sample co-.:'entraticn exceeds spike concentration by 4X or more R.
Sample results are rejected U
Analyte. was analyzed for, but not detected above the MDL, MDA, or LOD.
UI Gamma Spectroscopy--Uncertain identification X
ConsultCase Narrative, Data Summary package, or Project Manager concerning this qualifier Y
QCSamples were not spiked with this compotud A
RPD of sample and duplicate evaluated using +/-RL. Concentrations are <5X the RL h
Preparation or preservation holding time was exceeded.
The above sample is reported 6n a dry weight basis.
88
GENERAL ENGINEERING LABORATORIES, LLC 2040 Savage Road Charleston SC 29407 - (843) 556-8171 - www.gel.com Certificate of Analysis Company:
Connecticut Yankee Atomic Power Address:
362 Injun Hollow Rd East Hampton, Connecticut 06424
Contact:
Mr. Jack McCarthy Project:
Soils PO# 002332 Report Date: September 26, 2006 Client Sample ID:
SamplelID:
Matrix:
Collect Date:
Receive Date:
Collector:
Moisture:
9530-0004-012F 171.454026 TS 25-AUG-06 12-SEP-06 Cdlent 13%
Project:
Client ID:
Vol. Recv.:
YANK01204 YANK001 Parameter Qualifier Result Uncertainty LC TPU MIDA Units DF Analyst Date
'Time Batch Mt Rad Alpha Spec Analysis Alphaspec Am241, Cin, Solid ALL FSS Americium-241 U -0.00141 Curium-242 U -0.00764 Curium-243/244 U
0.0664 Alphaspec Pu, Solid-ALL FSS Plutonium-238 U
-0.0258 Plutoniumn-239/240 U
-0.106 Liquid Sctmt Pu241, Solid-ALL FSS
- Plutonium-241 U
-1.86 Rad.Gamma Spec Analysis Gamma, Solid-FSS GAM & ALL FSS 226 higrowth Waived Actinium-228 0.997 Americium-241 U -0.00476 d
Bismuth-212 0.556 Bismuth-214 0.631 Cesium-134 U
0.0353 Cesium-137 U
0.038 Cobalt-60 U -0.00113 Europium-152 U
0.0468 Europium-154 U -0.00539 Europium-155 U
0.127 Lead-212 0.958 Lead-214 0.690 Manganese-54 U
0.0384 Niobium-94 U
0.0189 Potassium-40 16.6 Radium-226 0.631
... Silver=108m--------
0.003a5 Thallium-208 0.280 Rad Gas Flow Proportional Counting GFPC, Sr90, solid-ALL FSS Strontium-90 U
-0.0242 Rad Liquid Scintillation Analysis LSC, Tritium Dist, Solid-HTD2,ALL FSS Tritium U
2.19
+/-0.0569
/-0.0642
+/-0.102 0.00 0.0286
.0.0452
+/-0.0571
+/-0.0642
.+/-0.102 0.0787 0.143 0.169
..0.349 0.348 pCi/g pCi/g pCi/g pci/g pCi/g
+/-0.128 0.120
+/-0.128 4-0.0627 0.120 +/-0.0638
+/-9.82 8.32
+/-9.82 17.4
.pCi/g
+/-0.226
/-0.0957
+/-0.325
+/-0.102 4-0.0271
/-0.0401
/-0.0236 1-0.0609
/-0.0755 1-0.0761
+/-0.0833
+/-0.0985
+/-0.0471
+/-0.0226
+/-1.01
+/-0.102
+/-0.0186 F/-0.0549
+/-0.0181 0.0716 0.0754 0.156 0.040 0.0255 0.0198 0.0192 0.0495 0.0617 0.070 0.0323 0.0348 0.0191 0.0174 0.134 0.040 0.0155 0.0224
+/-0.226
+/-0.0957
+/-0.325
+/-0.102
+/-0.0271
+/-0.0401
+/-0.0236
+/-0.0609
+/-0.0755
+/-0.0761
+/-0.0833
+/-0.0985
+/-0.0471
+/-0.0226
+/-1.01
+/-0.162
+/-0.0186 0.154 0.157 0.335 0.0847 0.0541 0.0423 0.0424 0.105 0.134
,0.145 0.0674 0.0736 0.0412 0.0373 0.309 0.0847 0.0331 0.0474 pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCilg pCi/g JASI 09/15106 1152 567824 JASI 09/16/06 0952 567825 JAS1 09/17/06 0602 567826 MJHI 09/20/06 1057 569468 KSDI 09/16/06 1622 567998 ATH2 09/17/06 0458 567994 0.0175 +/-0.0181 0.0386
+/-4.65 3.78
+/-4.65 8.02 89
GENERAL ENGINEERING LABORATORIES, LLC 2040 Savage Road Charleston SC 29407 - (843) 556-8171 - www.gel.com Certificate of Analysis Company:
Connecticut Yankee Atomic Power Address :
362 Injun Hollow Rd East Hampton, Connecticut Q6424
Contact:
Mr:. Jack McCarthy Project:
Soils PO# 002332 Report Date:
September 26, 2006 Client Sample ID:
Sample ID:
9530-0004-012F 171454026 Project:
Client 1ID:
Vol. Recv.:
YANK01204 YANK001 Parameter Qualifier Result Uncertainty LC TPU MDA Units DF Analyst Date Time Batch Mt Rad Liquid Scintillation Analysis Liquid Scint C14, Solid AllFSS Carbon-14 U
0.0855
+/-0.0887 0.0701 +/-0.0887 0.148 pCi/g AXD2 09/14/06 1155 567937 l
Liquid Scint Fe55, Solid-ALL FSS Iron-55 U
-17.7
+/-47.3 32.9
+/-47.3 68.4 pCi/g MXP[ 09/19/06 1335 567933 Liquid Scint Ni63, Solid-ALL FSS Nickel-63 U
-3.36
+/-5.39 4.63
+/-5.39 9.58 pCi/g MXPI 09/16/06 1036 567934 1 LiqUid Scint Tc99, Solid-ALL FSS Technetium-99 U
0.167
+/-0.285 0.235
+/-0.285 0.483 pCi/g KXRI 09/23/06 1040 567935 1
The following Prep Methods were performed Method
- . Descriptior.
Analyst Date Time Prep Batch Dry Soil Prep
. Dry Soil Prep GL-RAD-A-021 AXP2 09/12/06 1713 567634 The following Analytical Methods were performed Method Description I
2 3
4 5
6 7
8 9
10 11 12 DOE EML HASL-300, Am-05-RC Modified DOE EML lI-ASL-300, Pu-I,-RC Modified DOE EML HASL-300, Pu-I I-RC Modified EML HASL 300, 4.5.2.3 EPA 905.0 Modified EPA 906.0 Modified EPA 906.0 Modified EPA EERF C-01 Modified DOE RESL Fe-I, Modified DOE RESL Ni-l, Modified DOE EML HASL-300, Tc-02-RC Modified DOE EML HASL-300, Tc-02-RC Modified Surrogate/Tracer recovery Test Americium-243 Plutonium-242 Carrier/Traccr Recovery Carrier/Tracer Recovery Carrier/Tracer Recovery Alphaspec Am241, Cm, Solid ALL Alphaspec Pu, Solid-ALL FSS Liquid Scint Pu241, Solid-ALL FS GFPC, Sr90, solid-ALL FSS Liquid Scint Fe55, Sulid-ALL FS Recovery %
101 80 95 77 69 Acceptable Limits (15%-125%)
(15%-125%)
(25%-125%)
(25%-1257b)
(15%-125%)
90
GENERAL'ENGINEERING LABORATORIES, LLC 2040 Savage Road Charleston SC 29407 - (843) 556-8,171 - www.gel.com Certificate of Analysis Company:
Connecticut Yankee Atomic Power Address 362 Injun Hollow Rd East Hampton, Connecticut 06424 Report Date:
September 26, 2006
Contact:
Mr. Jack McCarthy
.Project:
Soils PO# 002332 Client Sample ID" 9530-0004-012F Proiect:
YANK01204 Sample ID:
171454026 Client ID:
YANK001 Vol. Recv.:
Parameter Qualifier Result Uncertainty LC TPU AIMDA Units DF Analyst Date Time Batch Alt Carrier/Tracer Recovery Liquid Scint Ni63, Solid-ALL FS 96 (25%-125%)
Carrier/Tracer Recovery Liquid Scint Tc99, Solid-ALL FS 82 (15%-125%)
Notes:
The Qualifiers in this report are defined as follows A quality control analyte recovery is outside of specified acceptance criteria Result is less than value reported Result is greater than value reported
- A The TIC is a suspected aldol-condensation product B
Target analyte was detected in the associated blank
.BD Results are either below the MDC or tracer recovery is low C
Analyte has been confirmed by GC/MS.analysis D
Results are reported from a diluted aliquot of the sample
.H Analytical holding time was exceeded J
Value is estimated NIA Spike recovery limits do not apply. Sample concentration exceeds soike concentration by 4X or more R
Sample results are rejected U
Analyte was analyzed for, but not detected above the MDL, MDA, orLOD.
UI Gamma Spectroscopy-Uncertain identification X
Consult Case Narrative, Data Sunmary package, or Project Manager concerning this qualifier Y
QC Samples were not spiked with this compound A
RPD of sample and duplicate evaluated using +/-RL. Coiicentrations are <5X the RL h
Preparation or preservation holding time was exceeded The above sample is reported on a dry weight basis.
91
GENERAL ENGINEERING LABORATORIES, LLC 2040 Savage Road Charleston SC 29407 - (843) 556-8171 - www.geLcom Certificate of Analysis Company:
Connecticut Yankee Atomic Power Address:
362 Injun Hollow Rd East Hampton, Connecticut 06424
Contact:
Mr. Jack McCarthy Project:
Soils PO# 002332 Report Date:
September 26, 2006 Client Sample ID:
Sample ID:
Matrix:
Collect Date:
Receive Date:
Collector:
Moisture:
9530-0004-002F 171454027 TS 2'8-AUG-06 12-SEP-06 Client 8.88%
Proiect:
YANKO1204
- Client ID:
YANKO01 Vol. Recv.:
Parameter Qualifier Result Uncertainty
'LC TPU MDA Units DF Analyst Date Time Batch MI Rad Alpha Spec Analysis Alphaspec Am241, Cm, Solid ALL FSS Americium-241 U -0.00881 Curium-242 U
0.00 Curium-243/244 U
0.0279 Alphaspec Pu, Solid-ALL FSS Plutonium-238 U
-0.123 Plutonium-239/240 U
-0.0307 Liquid Scint Pu24N, Solid-ALL FSS
- Plutonium-241 U
4.29 Rad Gamma Spec Analysis Gainmna,Solid-FSS GAM & ALL FSS 226 Ingrowth Waived Actinium-228 1.05 Americium-241 U
0.189 Bismuth-212 0.640 B ismuth-214 0.534 Cesium-134 in 0.00 Cesium-137 0.212 Cobalt-60 U
0.00179 Europium-152 U
-0.0207 Europium-154 U
0.058 Europium-155 U
0.0567 Lead-212 0.928 Lead-214 0.621 Manganese-54 U
-0.023 Niobium-94 U
0.00648 Potassium-40 13.6 Radium-226 0.534
.....- Silver--108m- --
......-U..... 0.0096...
Thallium-208 0.268 Rad Gas Flow Proportional Counting GFPC, Sr90, solid-ALL FSS Strontium-90 U
0.00564 Rad Liquid Scintillation Analysis LSC, Tritium Dist, Solid-HTD2,ALL FSS Tritium U
-0.294 i-/-0.0429 t-/-0.0778
+/-0.0741 0.0466 0.00 0.033
+/-0.0429
+/-0.0778
+1-0.0741
+/-0.0602 0.115 +/-0.0615
+/-0.0301 0.0574 +/-0.0302
+/-11.0 9.02
+/-11.0
+/-0.211
+/-0.105
+/-0.396
+/-0.111
+/-0.0395
+/-0.0494
+/-0.0253
+/-0.0668
+/-0.089
+/-0.0655
+/-0.0812
+/-0.118
+/-0.029
+/-0.0237
+/-1.14
+/-0.111
+/1-0.022
+/-0.058 0.0717 0.0909 0.146 0.0415 0.0289 0.0207 0.0214 0.0536 0.0571 0.0602 0.032 0.0378 0.0219 0.0202 0.143 0.0415 0,01.85 0.0219
+/-0.211
+/-0.105
+/-0.396
+/-0. 111
+/-0.0395
+/-0.0494
+/-0.0253
+/-0.0668
+/-0.089
+/-0.0655
+/-0.0812
+/-0.118
+/-0.029
+/-0.0237
+/-1.14
+/-0. I111
...._L-?._O0_22.*
+/-0.058
.0.193 0.108 0.166 0.316 0.201 18.9 0.157 0.190 0.318 0.0886 0.0617 0.0447 0.0481 0.114 0.129 0.125 0.0669 0.0802 0.0475 0.0434 0.339 0.0886 0.0394 0.0468 0.0307 9.55 pCilg pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g JASI 09/15/06 1152 567824 JAS1 09/16/06 0952 567825 JASI 09/17/06 0618 567826 MJHI 09/20/06 1732 569468 KSDI 09/16/06 1622 567998 ATH2 09/17/06 2009 567994
+/-0.0171
. 0.0137 +/-0.0171
+/-5.38 4.53
+/-5.38 92
GENERAL ENGINEERING LABORATORIES, LLC 2040 Savage Road Charleston SC 29407 - (843) 556-8171 - www.gel.com Certificate of Analysis Company:
Connecticut Yankee Atomic Power Address :
362 Injun Hollow Rd East Hampton, Connecticut 06424
Contact:
Mr. Jack McCarthy Project:
Soils PO# 002332 Report Date:
September 26, 2006
- Client Sample ID:
Sample ID:
9530-0004-003F 171454027 Proiect:
YANK01204 Client ID:
YANK001 Vol. Recv.:
Parameter Qualifier Result Uncertainty.
LC TPU MDA Units DF Analyst Date Time Batch MI Rad Liquid Scintillation Analysis Liquid Scint C14, Solid A1I,FSS Carbon-14 U
0.0578
+1-0.0876 0.0705 +/-0.0876 0.149 pCi/g AXD2 09/14/06 1433 567937 Liquid Scint Fe55, Solid-ALL FSS Iron-55 U
-12
+/-48.0 33.3
+/-48.0 69.2 pCi/g MXPl 09/19/06 1352 567933 Liquid Scint Ni63, Solid-ALL FSS Nickel-63 U
0.394
+/-6.74 5.65
+/-6.74 11.7 pCi/g MXPI 09/16/06 1107 567934 1
- Liquid Scint Tc99, Solid-ALL FSS Technetium-99 U -0.00867
+/-0.282 0.237
+/-0.282 0.487 pCi.g KXRI 09/23/06 1056 567935 J The following Prep Methods were performed Method Description Analyst Date Time Prep Batch Dry Soil Prep Dry Soil Prep GL-RAD-A-021 AXP2 09/12/06 1713 567634 S..The following Analytical Methods were performed Method Description I
'DOE EML HASL-300, Am-05-RC Modified 2
DOE EM-L HASL-300, Pu-1 I-RC Modified 3
DOE EML HASL-300, Pu.l l-RC Modified 4
EML HASL 300, 4.5.2.3 5
EPA 905.0 Modified 6
EPA 906.0 Modified 7
EPA 906.0 Modified 8
EPA EERF C-01 Modified 9
DOE RESL Fe-1, Modified 10 DOE RESL Ni-1, Modified 11 DOE EML HASL-300, Tc-02-RC Modified 12 DOE EML HASL-300, Tc-02-RC Modified Surrogate/Tracer recovery Test Recovery%
Acceptable Limits Americium-243 Plutonium-242 Can'ier/Tracer Recoveiy Canier/Tracer Recoveiy Carrier/Tracer Recoveiy A!phaspec Am241, Cm, Solid ALL Alphaspec Pu, Solid-ALL FSS Liquid Scint Pu241, Solid-ALL FE GFPC, Sa90, solid-ALL FSS Liquid Scint Fe55, Solid-ALL FS 70 91 83 83 67 (15%-125%)
(15%-125%)
(25%-125%)
(25%-125%)
(15%-125%)
93
GENERAL ENGINEERING LABORATORIES, LLC 2040 Savage Road Charleston SC 29407 - (843) 556-8171 - www.gel.com Certificate of Analysis Company:
Connecticut Yankee Atomic Power Address:
362 Injun Hollow Rd East Hampton, Connecticut 06424 Report Date: September 26, 2006
Contact:
Mr. Jack McCarthy Project:
Soils PO# 002332 Client Sample ID:
.9530-0004-003F Project:
YANK01204 Sample ID:
171454027 Client ID:
YANK001 Vol. Recv.:
Parameter Qualifier Result Uncertainty LC TPU MDA Units DF Analyst Date Time Batch Mt Carrier/Tracer Recovery Liquid Scint Ni63, Solid-ALL FS 85 (25%-1259o)
Carrier/Tracer Recovery Liquid Scint Tc99, Solid-ALL FS
.81 (15%-125%)
Notes:
The Qualifiers in this report are defined as follows A quality control analyte recovery is outside of specified acceptance criteria Result is less than value reported Result is greater than value reported A
The TIC is a suspected aldol-condensation product B
Target analyte was detected in the associated blank BD Results are either below the MDC or tracer recovery is low C
Analyte has been confinned by GC/MS analysis D
Results are reported from a diluted aliquot of the sample H
Analytical holding time was exceeded J : Value is estimated N/A Spike recovery limits do not apply. Sample concentration exceeds spike concentration by 4X or more R
Sample results are rejected U
Analyte was analyzed for, but not detected above the MIDL, MDA, or LOD.
UI Gamma Spectroscopy -- Uncertain identification X
Consult Case Narrative, Data Summary package, or Project Manager concerning this qualifier Y
QC Samples were not spiked with this compound A
RPD of sample and duplicate evaluated using +/-RL. Concentrations are <5X the RL h
Preparation or preservation holding time was exceeded The above sample is reported on a dry weight basis.
94
I Ii 11 QUALITY CONTROL DATA 95
GENERAL ENGINEERING LABORATORIES, LLC 2040 Savage Road Charleston SC 29407 - (843) 556-8171 - www.gel.com QC Summary Client:
Connecticut Yinkee Atomic Power 362 Injun Hollow Rd Report Date: September 26, 2006 Page 1 of 12 East Hampton, Connecticut
Contact:
Mr. Jack McCarthy Workorder:
171454 Parmname NOM Sampe Qual..
QC Units RPD%
REC%
Range AnIst Date Time Rad Alpha Spec Batch 567824 QC120118 1598 Amneficium-241 171450001 DUP Cufiumn-242 Curium-243/244 QC1201181600 LCS Amnericium-241 Cui-iui-242 Curiurn-243/244 U
0.0224 Uncert:
+/-0.0562 TPU:
+/-0.0563 U
0.029 Uncert:
+/-0.0568 TPU:
+/-0.0569 U
0.0152 Uncert:
+/-0.0812 TPU:
+/-0.0812 9.83 Uncert:
TPU:
Uncert:
TPU:
11.9 Uncert:
TPU:
U
-0.0344
+/-0.0558
+/-0.0558 U
0.00
+/-0.0576
+/-0.0576 U
-0.0054
+/-0.060
+/-0.060 9.33
+/-0.996
+/-1.40 U
0.092
+/-0.112
+/-0.113 10.9
+/-1.08
+/-1.58 U
-0.0214
+/-0.0709
+/-0.0711 U
0.019
+/-0.0757
+/-0.0757 U
0.00145
+/-0.0787
+/-0.0787 pCi/g 947 pCi/g 200 pCi/g 420 pCi/g
.(0% - 100%) JASI (0%o-100%)
(0%- 100%)
95 (75%-125%)
09/19/06 08:08 QC1201181597 Americium-241 MvlB Curium-242 Uncert:
TPU:
Uncert:
TPU:
Uncert:
.TPU:
pCi/g pCilg pCi~g
- pcilg, pCilg pci/g.
pcilg-92 (75%-125%)
09/15/06 11:52 Ctuiuni-243/244 QC1201181599 171450001 MS Amnericium-241 Cuium-242 Curium-243/244 13.0 U
0.0224 Uncert:
+/-0.0562 TPU:
+/-0.0563 U
0.029 Uncert:
+/-0.0568 TPU:
+/-0.0569 15.7 U
0.0152 Uncert: -..-
+/-0.0812 TPU:
+/-0.0812 U
12.3
+/-1.24
+/-1.79
-0.0661
+/-0.0458
+/-0.0463 17.3
+/-1.46
+/-2.33 95 (75%-125%)
09/19106 08:08 110 (75%-125%)
Batch 567825 QC1201181602 171450001 DUP Plutonium-238 U
-0.00319 U
-0.0577 pCi/g 179 (0%- 100%) JASI 09/16/06 09:52 96
GENERAL ENGINEERING LABORATORIES, LLC 2040 Savage Road Charleston SC 29407 - (843) 556-8171 - www.gel.com QC Summary Workorder:
171454 Page 2 of 12 Parmname Rad Alpha Spec Batch.
567825 NOM Samnle Oual OC Units RPD%
REC%
Ranee Anlstt Date Time NOM OC Units RPD%
REC%
Range AnIst Plutoniurn-239/240 QC1201181604 LCS Plutoniurn-238 Plutonium-239/240 QC1201181601 MVB PILttonium-238 Pltitonium-239/240 QC12QI 181603 171450001 MS Plutonium-238 Uncert:
TPU:
U Uncert:
- TPU:
Uncert:
TPU:
9.08 Uncert:
TPU:
Uncert:
. TPU:
Uncrt:
TPU:
+/-0.174
+/-0.174
-0.0638
+/-0.132
+/-0.132 Plutonium-239/240 B arch 567826 Uncert:
TPU 12.0 Uncert:
TPU Uncert:
TPU u
-0.00319
.+/-0.174
+/-0.174 U
-0.0638
+/-0.132
+/-0.132 u
626
+/-11.5
+/-11.5
+/-0.0594
+/-0.0597 U
-0.024
+/-0.0868
+/-0.0868 U
.0.0415
+/-0.0777
+/-0.0779 7.12
+/-0.872
+/-1.16 U
-0.0876
+/-0.107
+/-0.108 U
0.00165
+/-0.0898
+1-0.0898 U
-0.0197
+/-0.0981
+/-0.0981*'
10.3
+/-1.11
+/-1.53' U
-8.24
+/-11.0
+/-11.0 112
+/-16.4
+/-20.0 U
-2.99
+/-11.0
+/-11.0 104
+/-14.0
+/-17.1 pCi/g-pCilg pCi/g-pCi/g POi/g pCi/g pCi/g 91
. (0% - 100%)
(75%-125%)
(75%-125%)
09/16/06 09:52 (75%-125%)
86 09/16/06 09:52 78 (75%-125%)
09/16/06 09:52 QC1201181606 171450001 Plutonium-241 DUP v pCi/g 0
(0%- 100%) JASI QCI201181608 Plutoniumn-241 LCS QC1201181605 MB Plutonium-241 QC1201181607 171450001 TAS Plutonium-241 Rad..Ga aS pec Batch 569467 QC1201185426 171454001 DUP Actiniurn-228 127 Uncert:
TPU:
Uncert:
TPU:
138 U
Uncert:
TPU:
pci/g-pCi/g pCi/g 88 (75%-125%)
09/17/06 07:23 09/17/06 07:55 09/17/06 07:07 09/17/06 07:39 6.26
+/-11.5
+/-11.5 76 (75%-125%)
0.490 Uncert:
+/-0.141 0.519
+/-0.181
+/-0.181 pCi/g 6
(0% - 100%) MJH1 09/20/06 10:17 97
GENERAL ENGINEERING LABORATORIES, LLC 2040 Savage Road Charleston SC 29407 - (843) 556-8171 - www.gel.com QC Summary "Workorder:
171454 Page 3 of 12 Parmname NOM Sample Qual QC Units RPD%
REC%
Range Arist Date Time Rad Gamma Spec Batch 569467 Americium-241 Bismuth-212 Bismuth-214 Cesium-134 Cesium-137 Cobalt-60 Europium-152 Europium-154 TPU:
+/-0.141 U
0.112 U
0.023 Uncert:
+/-0.121
.+/-0.0494 TPU:
+/-0.121
+/-0.0494 U
0.163 0.569 Uncert:
+/-0.172
+/-0.253 TPU:
+/-0...72
+/-0.253 0.348 0.318 Uncert:
+/-0.081
+/-0.106 TPU:
+/-0.081
+/-0.106 u
.0.0339 U
0.0279 Uncert:
+1-0.017.
+/-0.0273 TPU:
+/-0.017
+/-0.0273 0.0796 0.0997 Uncert:
+/-0.0245
+/-0.0486
- TPU.
+/-0.0245
+/-0.0486 u
0.00766 U
0.00572 Uncert:
+/-0.0254
+/-0.0393 TPU:
+/-0.0254
+/-0.0393 U
0.000266 U
-0.00373 Uncert:
+/-0.0528
+/-0.0873 TPU:
+/-0.0528
+/-0.0873 U
0.0642 U
-0.00757 Uncert:
+/-0.080
+/-0.0872 TPU:
+/-0.080
+/-0.0872 UI 0.00 U
-0.0133 Uncert:
+/-0.100
+/-0.0587 TPU:
+/-0.100
.+/-0.0587 0.465 0.532 Uncert:
+/-0.0565
+/-0.078 TPU:
+/-0.0565
+/-0.078 0.417 0.402 Uncert:
+/-0.0853
+/-0.107 TPU:
+/-0.0853
+/-0.107 U
0.0199 U
0.0314 Uncert:
+/-0.019
+/-0.0152 TPU:
+/-0.019
+/-0.0152 U
0.016 U
0.00458 Uncert:
+/-0.0153
+/-0.023 TPU:
+/-0.0153
+/-0.023 9.54 7.35 Uncert:
+/-0.855
+4-0.957 TPU:
+1-0.855
+/-0.957 0.348 0.318 Uncert:
+/-0.081
+/-0.106 TPU:
+/-0.081
+/-0.106 U
-0.0181 U
-0.00342 Uncert:
+/-0.0169
+/-0.0221 pCi/g 132 pCi/g 11 pCi/g 9
pCi/g 19 pCi/g 22 pCi/g 29 pCi/g 231 pCi/g 254 pCi/g 236 pCi/g 13 pCi/g 4
pCi/g 45 pCi/g 111 pCi/g 26*
pCi/g 136 9 pCi/g 136 (0%- 100%)
(0% - 100%)
(0%- 100%)
(0%- 100%)
(0% - 100%)'
(0% - 100%)
(0% - 100%)
(0% - 100%)
(0%- 100%)
(0%-20%)
(0%- 100%)
(0%- 100%)
(0% - 100%)
(0% - 20%)
(0%- 100%)
Europium-155 Lead-212 Lead-214 Manganese-54 Niobium-94 Potassium-40 Radium-226 -.
Silvel-108m 98
GENERAL ENGINEERING LABORATORIES, LLC 2040 Savage Road Charleston SC 29407 - (843) 556-8171 - www.gel.com Workorder:
171454 Parynname Rad Gamma Spec Batch 569467 Thallium-208 QC1201185427 LCS Actinium-228 Americium-241 Bismufh-212 Bismuth-214 Cesium-134 Cesium-137 Cobalt-60 Europium-152 Europium-154 Europium-155 Lead-212 Lead-214 Manganese-54 Niobium-94 Potassium-40 QC Summary Sample Oual OC Page 4 of 12 REC%
Ranee AnIst Date Time NOM Units RPD%
TPU:
Uncert:
TPU:
Uncert:
TPU:
23.4 Uncert:
TPU:
Uncelt:
TPU:
Uncert:
TPU:
Uncert:
TPU:
9.57 Uncert:
TPU:
14.4 Uncert:
TPU:
Uncert:
TPU:
Uncert:
TPU:
Uncert:
TPU:
Uncert:
TPU:
Uncert:
TPU:
Uncert:
. TPU:
Uncert:
TPU:
+/-0.0169 0.150
+/-0.0344
+/-0.0344
+/-0.0221 0.196
+/-0.0614
+/-0.0614 U
-0.268
+/-0.809
+1-0.809 27.3
+/-2.24
+/-2.24 U
1.83
+/-1.37
+/-1.37 U
-0.0223
+/-0.333
+/-0.333 U
-0.0463
+/-0.194
+/-0.194 10.9
+1-1.16
+/-1.16 15.6
+/-0.830
+/-0.830
.U 0.0299
+/-0.355
+/-0.355 U
0.155
+/-0.383
+/-0.383 U
0.312
+/-0.288
+/-0.288 U
-0.036
+/-0.187
+1-0.187
.U 0.173
+/-0.264
+/-0.264 U
0.167
+/-0.195
+/-0.195 S
/0.04-8
+/-0.161
+/-0.161 U
0.285 pCi/g 27 (0%- 100%)
pCi/g pCilg pCilg POi/g PCi/g-Pci/g pcilg-pCilg Pcilg P (flg 09/20/06 07:46 117 (75%-125%)
114 (75%-125%)
108 (75%-125%)
99
GENERAL ENGINEERING LABORATORIES, LLC 2040 Savage Road Charleston SC 29407 - (643) 556-8171 - www.gel.com QC Summary Workorder:
171454 Page 5 of 12 Parniame NOM Sample Qual QC Units RPD%
REC%
Range Anrist Date Time Rad Ganrna Spec Batch 569467 Radium-226 Silver-losm Thallium-208 QC1201185425 MB Actinium-228 Americiumn-241 Bismuth-212 Bismudh-214 Cesium-134 Cesium-137 Uncert.:
TPU:
Uncert:
TPU:
Uncert:
,TPU:
Uncert:
TPU:
Uncert:
TPU:
Uncert:
TPU:
Uncert:
TPU:
Uncert:
TPU:
Uncert:
. TPU:
Unccrt:
TPU:
Uncert:
TPU:
Uncert:
TPU:
Uncert:
TPU:
+/-1.48
+/- 1.48 U
-0.0223
+/-0.333
+/-0.333 U
.0.0663
+/-0.148
+/-0.148 U
-0.0912
+/-0.189
+/-0.189 U
0.0416
+/-0.0452
+/-0.0452 U
-0.081
+/-0.0804
+/-0.0804 U
-0.0379
+/-0.0881
+/-0.0881 U
.0.0442
+/-0.0324
+/-0.0324 U
0.000607
+/-0.0119
+/-0.0119 U -7.090E-05
+/-0.0117
+/-0.0117 U
-0.00242
+/-0.0107
+/-0.0107 U.
0.0294
+/-0.0328
+/-0.0328 U
0.00616
+/-0.0372
+/-0.0372 U
-0.0165
+/-0.0359
+/-0.0359 U
0.0183
-_ +L0.029_7.---
+/-0.0297 U
0.0306
+/-0.0253
+/-0.0253 Pbi/g PCi/g PCi/g-pG i/g pCi/g pCi/g Pci/g PCi/g PCilg pCilg PCi/g pCi/g pCilg-(75%- 125%)
09/20/06 10:02 Cobalt-60 Europium-152 Etuopium-154 Etuopium-155 Lead-212 Uncert:
TPU:
Uncert:---
TPU:
Lead-214 Uncert:
TPU:
100
.GENERAL ENGINEERING LABORATORIES, LLC 2040 Savage Road Charleston SC 29407 - (843) 556-8171 - www.gel.com QC Summary Workorder:
171454 Page 6 of 12 Parmname NOM Sample Qual QC Units RPD%
REC%
Range Anist Date Time 1*00.ia...113.
Rnad Gamma S;pec
' Batch 5S Manganese-54 69467 Niobium-94 Potassium-40 Radium-226 Silver-108m Thallium-208 Uncert:
TPU:
Uncert:
TPU:
Uncert:
TPU:
Uncert:
TPU:
Uncert:
TPU:
Uncert:
TPU:
U
.0.00138 pCi/g
+1-0.0123
+/-0.0123 U
0.00583 pCi/g
+/-0.0111
+/-0.O111 U
0.0485 pCi/g
+/-0.132
+/-0.132
- U 0.0442 pCi/g
+/-0.0324
+/-0.0324 U
0.00287 pCi/g
+/-0.012
- -/-o.o12 U
0.00554 pCi/g
+/-0.015
+/-0.015 Batch 569468 QC1201185429 171454021 DUP Actinium-228 0.966 1.23 pCi/g 24 Uncert:
+/-0.205
+/-0.142 TPU:
+1-0.205
+/-0.142 Americium-241 U
0.0256 U
0.023 pCilg 11 Uncert:
+/-0.0283
+/-0.133 TPU:
+/-0.0283
+/-0.133 Bismuth-212 0.535 0.483 pCi/g 10 Uncert:
+/-0.397
+1-0.186 TPU:
+/-0.397
+/-0.186 Bismuth-214 0.783 0.643 pCi/g 20 Uncert:
+/-0.136
+/-0.0859 TPU:
+/-0.136
+/-0.0859 Cesium-134 U
0.0136 U
0.0362 pCi/g 91 Uncert:
- +/-0.049
+/-0.0274 TPU:
+/-0.049
+/-0.0274 Cesium-137 U
0.00736 U
0.00184 pCi/g 120 Uncert:
+/-0.0315
+/-0.0192 TPU:
+/-0.0315
+/-0.0192 Cobalt-60 U
-0.0106 U
-0.00297 pCi/g 113 Uncert:
+/-0.0307
+/-0.0202 TPU:
+/-0.0307
+/-0.0202 Europium-152 U
-0.0362 U
-0.0113 pCi/g 105 Uncert:
+/-0.0681
+!-0.0466
-TPU:.W-...
/-0.0681-----------+/-0.0466--
EW-opium-i54 U
-0.0783 U
-0.0413 pCi/g 62 Uncert:
+/-0.125
+/-0.0546 TPU:
+/-0.125
+/-0.0546 Europium-155 U
0.0611 U
0.0412 pCi/g 39 (0% - 100%) MJH1 09/20/06 17:33 (0%- 100%)
(0% - 100%)
(0%- 100%)
(0%-1(0O%)
(0%- 100%)
(0%- 100%)
(0%- 100%)
(0%- 100%)
(0%- 100%)
101
GENERAL ENGINEERING LABORATORIES, LLC 2040 Savage Road Charleston SC 29407 - (843) 556-8171 - www.gel.com QC Summary Workorder:
171454 Page 7 of 12 Parmname NOM Sample Qual QC Units RPD%
REC%
Range Anist Date Timie Batch 5
Lead-212 Lead-214 Manganese-54 Niobium-94 Potassium-40 Radium-226 Silver-I O8m Thallium-208 69468 Uncert:
+/-0.0653 TPU:
+/-0.0653 0.866 Uncert:
+/-0.084 TPU:
+/-0.084 0.680 Uncert:
+/-0.118 TPU:
+/-0.118 U
0.0469 Uncert:
+/-0.043 TPU:
+/-0.043 U
-0.00108 Uncert:
+/-0.0287 TPU:
+/-0.0287 14.8 Uncert:
+/-1.27 TPU:
+/-1.27 0.783 Uncert:
+/-0.136 TPU:
+/-0.136 U
0.0177 Uncert:
+/-0.0238 TPU:
+/-0.0238 0.316 Uncert:
+/-0.0603 TPU:
+/-0.0603
+/-0.0564
+1-0.0564 0.927
+/-0.0596
+/-0.0596 0.767
+/-0.070
+/-0.070 U
0.00508
+/-0.0169
+/-0.0169 U
0.00263
+/-0.0164
+/-0.0164 17.8
+/-0.845
+/-0.845 0.643
+/-0.0859
+/-0.0859 U
-0.0126
+/-0.0156
+/-0.0156
. 0.296
+/-0.0351
+1-0.0351 U
0.341
+/-0.793
+/-0.793 26.2
+/-2.16
+1-2.16 U
0.204.
+/-1.33
+/-1.33 U
-0.188
+/-0.328
+/-0.328 U
0.093
+/-0.206
+/-0.206 10.5
+1-1.14
+/-1.14 15.3
+1-0.820
+/-0.820 pCi/g 7
pCL/g 12 pCi/g 161 pCi/g 481 pCi/g
.18 (0% - 20%)
(0% - 20%)
(0%- 100%)
(0%- 100%)
(0%- 20%)
pCi/g 20 (0% - 100%)
pCi/g 1210 pCi/g 7
(0%- 100%)
(0%- 100%)
Actinium-228 Ameliciumn-24 I
.LCS Uncert:
TPU:
23.4 Uncert:
.TPU:
Bismuth-212 Bismuth-214 Cesium-134 Ccsium-137 Cobalt-60 Uncect:
- .TPU:
Uncert:
- TPU:
Uncert:
TPU:
9.57 TPU:
14.4 Uncert:
TPU:
pCi/g pCi/g pCi/g pCi/.g pCi/g-pCi/g-09/20/06 08:54 112 (75%-125%)
110 (75%-125%)
106 (75%-125%)
102
GENERAL ENGINEERING LABORATORIES, LLC 2040 Savage Road Charleston SC 29407 - (843) 556-8171 - www.gel.com Workorder:
171454 Parmname Rad Gamma Spec B atch 569468 Europium-152 Europiumn-154 Europium-155 Lead-212 Lead-214 Manganese-54 Niobium-94 Potassium-40 Radium-226 Silver-108m Thallium-208 QC1201185428 MB Actinium-228 Americium-241 Bismuffi-212 Ce..Bismuth-2-143 Cesium-134 QC Summary Page 8 or 12 Sample Qual QC Units RPD%
REC%
Range AnIst Date Time NOM Uncert:
TPU:
Uncert:
TPU:
Unceit:
TPU:
Uncert:
TPU:
Uncert:
TPU:
Uncert:
TPU:
Uncert:
TPU:
Uncert:
TPU:
Uncert:
TPU:
Uncert:
TPU:
Uncert:
TPU:
Uncert:
TPU:
Unceit:
TPU:
Uncert:
TPU:
Uncert:
TPU:
Uncert:
U 0.480 pCi/g
+1-0.690
+/-0.690 U
0.0278 pCilg
+/-0.420
+/-0.420 U
-0.105 pCi/g
+/-0.324
+/-0.324 U
-0.136 pCi/g
+/-0.185
+/-0.185 U
" 0.145 pCi/g
+/-0.273:
+/-0.273.
.U
-0.00508 pCi/g
+/-0.182
+/-0.182 U
-0.0802 pCi/g
+/-0.154
+/-0.154 U
0.856 pCi/g
+/-1.60
+/-1.60 U
-0.188 pCi/g
+/-0.328
+/-0.328 U
0.0696 pCi/g
+/-0.145
+/-0.145 U
0.00973 pCi/g
+/-0.173
+1-0.173 U
. 0.0896 pCi/g
+/-0.0637
+/-0.0637 U
-0.00606 pCi/g
+/-0.0192
+/-0.0192 U
0.132 pCi/g
+/-0.146
+/-0.146 U.
0.029 p3Cg
+/-0.0379
+/-0.0379 U
-0.0057 pCi/g
+/-0.0209 (75%-125%)
09/20/06 17:32 103
GENERAL ENGINEERING LABORATORIES, LLC 2040 Savage Road Charleston SC 29407 - (843) 556-8171 - www.gel.com Workorder:
171454 QC Summary Page 9 of 12 Parmname NOM Sample Qual QC Units
.RPD%
REC%
Range Amist Date Time Rad Gamma Spec Batch" 569468 TPU:
Cesium-137 Cobalt-60 Eu'opium-152 Europium-154 Europium-155 Lead-212 Lead-214 Manganese-54
- Niobium-94 Potassium-40 Radium-226 Silver-108m Uncert:
TPU:
Uncert:
TPU:
Uncert:
TPU:
Uncert:
TPU:
Uncert:
TPU:
Uncert:
TPU:
.Uncert:
TPU:
Uncert:
TPU:
Uncert:
TPU:
Unceut:
TPU:
Uncert:
TPU:
Uncert:
TPU:
Uncert:
TPU:
+A0.0209 U
0.0192
.+/-0.0192
+/-0.0192 U
-0.00341
+/-0.0192
+/-0.0192 U
-0.019
+1-0.0438
+1-0.0438 U
0.0245
+/-0.0504
+/-0.0504 U
0.0117
+/-0.0339
+/-0.0339 U
0.048
+/-0.0241
+/-0.0241 U
0.0142
- +/-0.0503
+/-0.0503 U
0.0084
+/-0.0194
+/-0.0194 U
0.00987
+/-0.0159
+/-0.0159 U
0.049
+/-0.201
+1-0.201 U
0.029
+/-0.0379
+/-0.0379 U
0.00375
+/-0.0148
+/-0.0148 U
0.00107
+/-0.0293.
+/-0.0293 PCilg PCilg pCilg PCilg' pCilg pCilg pCi/g pCi/g PCi/g PCi/g pCilg-pCi/g pCi/g Thallium-208 Rad Gas Flow Batch 567998 Q QU10 L 181990 171450001 D0U.P Strontium-90 QC1201181992 LCS Stiontium-90 Uncert:
TPU:
1.74
-... 0.00357
+/-0.01S9
+/-0.01 89
-U- 00343-
+/-0.016
+/-0.016
- PC i/g -
0 -
- -- -(0% ---100 To) -K-S D I -- 09/-16/06 -16:22 --
1.60 pCilg 92 (75%-125%)
09/16/06 16:22 104
GENERAL ENGINEERING LABORATORIES, LLC 2040 Savage Road Charleston SC 29407 - (843) 556-8171 - www.gel.com QC Summary Workorder:
171454 Page 10of 12 Parmname NOM Sample Qual QC Units RPD%
REC%
Range Arist Date Time Batch 567998 QC1201181989 MB" Strontum-90 QC1201181991 171450001 MS Strontium-90 Rad Liquid Scintillation Batch 567933 QC1201181850 171450001 DUP Iron-55 QC1201181852 LCS Iron-55 QC1201181849
- v[Br h'on-55 QC1201181851
!171450001 MS h'on-55 Uncert:
.TPU:
Uncet:
TPU:
+/-0.0923
+/-0.104 U
0.00814
+/-0.0156
+/-0.0156 pCilg pCi/g 09/16/06 16:22 09/16/06 16:22 1.59 U
Uncert:
TPU:
.U Uncert:
TPU:
625 Uncert:
TPU:
Uncert:
TPU:
703 U
Uncert:
TPU:
0.00357
+/-0.0189
+/-0.0189
-9.33
+/-42.3
+/-42.3 1.31
+/-0.0727
+/-0.0821 83 (75%-125%)
U
-6.78
+1-58.7
+/-58.7 pCi/g 0
(0% - 100%) q4XPl 599
+1-50.6
+/-63.3 U
9.07
.+/-33.0
+/-33.0 pCi/g-pCi/g pCi/g 96 (75%-125%)
09/19/06 14:59 09/19/06 15:32 09/19/06 14:42 09/19/06 15:15
-9.33
+/-42.3
+/-42.3 Batch 567934 635
+/-62.9
+/-75.0
-1.49
+/-6.32
+/-6.32 90 (75%-125%)
QC1201181855 171450001 DUP Nickel-63 U
-2.65 Uncert:
+/-6.01 TPU:
+/-6.01 U
pCi/g 0
(0% - 100%) A4XPI QC1201181857 LCS Nickel-63 QC1201181954
]MB Nickel-63 512 Uncert:
TPU:
456
+/-16.3
+/-21.9 Uncert:
TPU:
QC1201181856 171450001 MS Nickel-63 594 U
U ncert:-..
TPU:
U
. -0.881
+/-5.53
+/-5.53 pci/g pCi/g, pCl'g" 89 (75%-125%)
09/16/06 13:14 09/16/06 14:17 09/16/06 12:42 09116/06 13:45
-2.65
_./_=6.01-
+/-6.01 544
+/-18.3
_...-..2...3
+1-26.2 92 (75%-125%)
Batch 567935 QC1201181859 171454026 DUP Technetium-99 U
0.167 U
-0.187 pCi/g 0
(0%- 100%) KXRI 09/23/06 12:01 105
GENERAL ENGINEERING LABORATORIES, LLC 2040 Savage Road Charleston SC 29407 - (843) 556-8171 - www.gel.com QC Summary Workorder:
171454 Parmname Page 11 of 12 NOM Samnle Oual OC Units RPD %
REC%
Range Anist Date Time Rad Liquid Scintillation Batch 567935 QC1201181861 Technetium-99 LCS QC1201181858 MB Technetium-99 QC1201181860 171454026 MS Technetiumn-99 Uncert:
TPU:
12.9 Uncert:
TPU:
Uncert:
TPU:
13.0 U
Uncert:
TPU:
+/-0.285
+/-0.285 12.6
+/-0.514
+/-0.588 U
0.0238
+/-0.252
+/-0.252 pCilg pCilg pCi/g 98 (75%-125%)
99 (75%-125%)
09/23/06 12:34 09/23/06 11:45 09/23/06 12:18
+/-0.284
+/-0.284
.0.167
+/-0.285
+/-0.285 Batch 567937 QC1201181863 171454026 DUP Carbon-14 QC1201181865 LCS Carbon-14 QC1201181862 MB Carbon-14
- QC1201181864
'171454026 MS Carbon-14 U
0.0855 Uncert:
+/-0.0887 TPU:
+/-0.0887 U
12.8
+/-0.552
+/-0.623 0.0747
+/-0.0883
+/-0.0883 6.81
+/-0.458
+/-0.470 pci/g 0
(0% - 100%) UMD2 6.66 Uncert:
TPU:
Uncert:
TPU:
7.13 U
Uncert:
TPU:
U 0.0127
+/-0.0794
+/-0.0794 pCilg pCilg pci/g 102 (75%-125%)
09/14/06 19:29 09/14/06 20:34 09/14/06 18:42 09/14/06 20:17 0.0855
+/-0.0887
+/-0.0887 Batch 567994 6.82
+/-0.448
+/-0.460
-0.623
+/-4.58
- +/-4.58 96 (75%-125%)
QC1201181978 Tritium QC1201181980 Titidam 171454026 DUP U
2.19 Uncert:
+/-4.65 TPU:
+/-4.65 U
pCi/g
TPU:
Uncert:
-.-.------T-PU:- _
65.7 U
Uncert:
TPU:
61.4
+/-7.48
+/-7.56 U
0.459
+/-4.46
+/-4.46 60.0
+/-7.47
+/-7.54 pCi/g pCi/.g pci/g 94 (75%-125%)
91 (75%-125%)
09/17/06 07:37 09/17/06 08:40 09/17/06 07:05 09/17/06 08:08 2.19
+/-4.65
+/-4.65 106
GENERAL ENGINEERING LABORATORIES, LLC 2040 Savage Road Charleston SC 29407 - (843) 556-8171 - www.gel.com QC Summary Workorder:
171454 Page 12 of 12 Parnnanie NOM Sample Qual QC Units RPD%
REC%
Range AnIst Date Time Notes:
The Qualifiers in this report are defined as follows:
A quality control analyte recoveryis outside of specified acceptance cmiteria Result is less than value reported Result is greater than value reported A
The TIC is a suspected aldol-condensation product B
Target analyte was detected in the associated blank BD Results are either below the MDC or tracer recovery is low C
Analyte has been confirmed by GC/MS analysis D
Results are reported from a diluted aliquot of the sample H
Analytical holding time was exceeded J
Value is estimated N/A Spike recovery limits do not apply. Sample concentration exceeds spike concentration by 4X or more R
Sample results are rejected U
Analyte was analyzed for, but not detected above the MDL, MDA, or LOD.
UI Gamma Spec t'osco.)y--Uncertain identification X
Consult Case Nuanative, Data
..,immary package, or Project Manaecr concerning this qualifier
- Y QC Samples were not spiked with this compound
.A RPD of sample and duplicate evaluated using +/-RL. Concentrations are <5X the RL
- h Preparation or preservation holding time was exceeded N/A indicates that spike recovery limits do not apply when sample concentration exceeds spike cone. by a factor of 4 or more.
- Indicates analyte is a surrogate compound.
A The Relative Percent Difference (RPD) obtained from the sample duplicate (DUP) is evaluated against the acceptence criteria when the sample is greater than five times (5X) the contract required detection limit (RL). In cases where either the sample or duplicate value is less than 5X the RL, a control limit of +/- the RL is used to evaluate the DUP result.
For PS, PSD, and SDILT results, the values listed are the measw'ed amounts, not final concentrations.
Where the analytical method has been performed under NELAP certification, the analysis has met all of the requirements of the NELAC standard unless qualified on the QC Summary.
.107
CENTRAL. PENINSULA SURVEY UNIT 9530-0004 RELEASE RECORD ATTACHMENT 4 (DQA RESULTS)
CENTRAL PENINSULA SURVEY UNIT 9530-0004 RELEASE RECORD ATTACHMENT 4A (PRELIMINARY DATA REVIEW)
PRELIMINARY DATA REVIEW FORM Survey Unit:
9530-0004 Survey Unit Name:
Central Peninsula Classification : 3 Survey Media:
Soil Type of Survey:
Final Status Survey Type of Measurement:
Radionuclide Specific lumber of Measurements :
15 BASIC STATISTICAL QUANTITIES Cs-137 Target Level (pCi/g):
5.38E+00 Minimum Value:
2.06E-02 Maximum Value:
3.53E-0I Mean :
1.48E-0 1 Median :
1.36E-01 Standard Deviation :
1.07E-01 Sample Identification 9530-0004-001F 9530-0004-002F 9530-0004-003F 9530-0004-004F 9530-0004-005F 9530-0004-006F 9530-0004-007F 9530-0004-008F 9530-0004-009F 9530-0004-010F 9530-0004-011F 9530-0004-012F 9530-0004-013F 9530-0004-014F 9530-0004-015F Reported Results Cs-137 Concentration (pCi/g) 1.41E-01 2.76E-0 I 2.12E-01 2.97E-02 1.99E-01 7.96E-02 3.53E-01 1.44E-01 1.36E-01 6.45E-02 9.81E-02 3.80E-02 8.70E-02 3.36E-01 2.06E-02 Detect?
+
+
+
+
+
+
+
+
+
+/-
+
+
+
Fraction of Target Level 0.026 0.051 0.039 0.006 0.037 0.015 0.066 0.027 0.025 0.012 0.018 0.007 0.016 0.062 0.004 J~kk
(
,6:2 Submitted by/DateJ "4 61,4 1 of 1
CENTRAL PENINSULA SURVEY UNIT 9530-0004 RELEASE RECORD ATTACHMENT 4B (GRAPHICAL REPRESENTATION OF DATA)
FREQUENCY PLOT FOR CESIUM-137 Survey Unit: 9530-0004 Survey Unit Name: Central Peninsula Mean: 1.48E-01 pCi/g F.requency. P For C
I 3 Frequency Plot For 0s-137 10 Cr U..
8 6
4 2
0 3,74E-01 2.06E-02 1.09E-01 1.97E-01 2.85E-01 Upper End Value (pCi/g)
Upper End Value 2.06E-02 1.09E-01 I.97E-01 2.85E-01
.74.E-01 Total:
Observation Frequency 1
6 3
'3 2
15 Observation Frequency 7%
40%
20%
20%
13%
100%
Submitted by/Date Review d by/D te 1 of 1
QUANTILE PLOT FOR CESIUM-137 Survey Unit:
9530-0004 Survey Unit Name: Central Peninsula Mean:
1.48E-01 pCi/g Quantile Plot For Cs-137 4.OOE-01.
3.50E-01 3.00E-Q1 S2.50E-01 S2.00E-01 0D 1.50E-01 0
l.OQE-Ol fI
........ i -
i-i
.10..........
........ i............
N 5,OOE-02 0.OOE+0O a
0 20 40 60 80 100 Percentage Cs-137 Rank Percentage 2.06E-02 1
3%
2.97E-02 2
10%
3.80E-02 3
17%
6.45E-02 4
23%
7.96E-02 5
30%
8.70E-02 6
37%
9.8 1E-02 7
43%
1.36E-01 8
50%
I.41E-01 9
57%
1.44E-01 10 63%
1.99 I-01 I1 70%
2.12E-01 12 77%
2.76E-01 13 83%
3.36E-01 14 90%
3.53 E-01 15 97%
2,
Submitted b /Date N.
z9 z0-7 Reviewed by! ate
CENTRAL PENINSULA SURVEY UNIT 9530-0004 RELEASE RECORD ATTACHMENT 4C (SIGN TEST)
Connecticut Yankee Decommissioning Project Health Physics Procedure GPP-GGGR-R5121-001 Attachment A, Rev CY-001 MAJOR Sign Test Calculation Sheet For A Single Radionuclide or Gross Activity Measurements Survey Area Number: 9530 Survey Unit Number: 0004 Survey Area Name: Central Peninsula WPIR#: 2006-0038 Classification: 3 Type I (cc error): 0.05 (N): 15.
Radionuclide: Cs-137 DCGL: 5.38 Results (pCi/g)
DCGL - Results Sign 1.41E-0I 5.24E+00 2.76E-01 5.1OE+00 1
2.12E-0I 5.17E+00 2.97E-02 5.35E+00 1.99E-01 5.18E+00 7.96E-02 5.30E+00 1
3.53E-01 5.03E+00 1.44E-01 5.24E+00 1
1.36E-01 5.24E+00 1
6.45E-02 5.32E+00 9.81 E-02 5.28E+00 3.80E-02 5.34E+00 1
8.70E-02 5.29E+00 3.36E-01 5.04E+00 1
2.06E-02 5.36E+00 1
Number of positive differences (S+): 15 Critical Value: 11 7* *,**c&
_V' Performed by:
Independent R Survey Unit Meets Acceptance Criterion Date:
-Q/ý- 61e6 Date:
'I0(,
Page 1 of 1
CENTRAL PENINSULA SURVEY UNIT 9530-0004 RELEASE RECORD ATTACHMENT 4D (QC SPLIT RESULTS)
Health Physics Procedure 24265-000-GPP-GGGR-R5124-000-Rev.CY-000 Attachment A Health Physics Procedure 24265-000-GPP-GGGR-RS I 24-000-Rev.CY-000 Attachment A Split Sample Assessment Form Survey Area#: 9530 Survey Unit #: 0004 Survey Unit name: Central Peninsula Sample Plan or WPIIR#: 2005-0038 SML#: 9530-0004-004 Sample
Description:
Comparison of split samples collected, from sample measurement location #4 and analyzed using gamma spectroscopy by off-site Vendor Laboratory. The standard sample was 9530-0004-004F, the comparison sample was 9530-0004-004FS.
STANDARD COMPARISON Radionuclide Activity Standard Resolution Agreement Activity Standard Comparison Acceptable Value Error Range Value Error Ratio (Y/N)
K-40 11.5 4.24E-1 27 0.75-1.33 11.2 6.70E-1 0.97 Y
Comments/Corrective Actions: Not enough Cs-137 to yield an acceptable Resolution Table is provided to show acceptance criteria used to assess split samples.
Resolution 4-7 8-15 16 - 50 51 -200
>200 Agreement Range 0.5 -2.0 0.6-1.66 0.75 - 1.33 0.80 - 1.25 0.85-1.18 Page 1 of 1
Health Physics Procedure 24265-000-GPP-GGGR-R5124-000-Rev.CY-000 Attachment A Health Physics Procedure 24265-O00-GPP-GGGR-R5 1 24-000-Rev.CY-000 Attachment A Split Sample Assessment Form Survey Area#: 9530 Survey Unit #: 0004 1 Survey Unit name: Central Peninsula Sample Plan or WPIR#: 2005-0038 I SML#: 9530-0004-009 Sample
Description:
Comparison of split samples collected from sample measurement location #9 and analyzed using garmna spectroscopy by off-site Vendor Laboratory. The standard sample was 9530-0004-009F, the comparison sample was 9530-0004-009FS.
STANDARD COMPARISON Radionuclide Activity Standard Resolution Agreement Activity Standard Comparison Acceptable Value Error Range Value Error Ratio (YIN)
Cs-137 1.36E-1 2.56E-2 5
0.5-2.0 1.1 IE-1 1.82E-2 0.82 Y
Comments/Corrective Actions: N/A Table is provided to show acceptance criteria used to assess split samples.
Resolution Agreement Range 4-7 0.5-2.0 8-15 0.6-1.66 16 -50 0.75-1.33 51 -200 0.80- 1.25
>200 0.85-1.18 6--
Page 1 of 1
CENTRAL PENINSULA SURVEY UNIT 9530-0004 RELEASE RECORD ATTACHMENT 4E (COMPASS DQA WITH POWER CURVE)
eDQA Surface Soil Report Assessment Summary Site:
Planner(s):
Survey Unit Name:
Report Number:
Survey Unit Samples:
Reference Area Samples:
Test Performed:
Judgmental Samples:
Assessment
Conclusion:
9530-0004 McCarthy 16
/4, Central Peninsula 2
15 0
Sign Test Result:
Not Performed 0
EMC Result:
Not Performed Reject Null Hypothesis (Survey Unit PASSES)
Retrospective Power Curve
= 0.9 0.8 0.7 i
0.6 0.5 0.4 0.3
- 0.2 L
0.1
¢-
0 ft 0
1 2
3 4
5 Soil Concentration ( Ci/g), including background Prospective Power W
1-beta Actual Power LBG-R Estimated Power DCGL Retrospective Power 6
COMPASS v.0.0 11128/2006 Page I