May 15, 2007 Tennessee Valley Authority ATTN: Mr. Preston D. Swafford, Interim Chief Nuclear Officer and Senior Vice President 6A Lookout Place 1101 Market Street Chattanooga, TN 37402-2801
SUBJECT:
BROWNS FERRY NUCLEAR PLANT, UNIT 1 - AUTHORIZATION TO RESTART - DOCKET NO. 50-259 This letter documents the U.S. Nuclear Regulatory Commissions (NRCs) decision regarding the Tennessee Valley Authoritys (TVA) plan to restart the Browns Ferry Nuclear Plant Unit 1 (BF1). Based on our extensive review of TVA's activities, completion of necessary revisions to the licensing and design bases, satisfactory inspection results, the recommendations of the NRC's Brown's Ferry Restart Oversight Panel and consultation with the Director of the Office of Nuclear Reactor Regulation (NRR) and the Executive Director for Operations (EDO), I authorize TVA to restart Browns Ferry Unit 1.
In a letter dated September 17, 1985, the NRC documented the understanding that TVA would not restart its reactors, including BF1, without NRC concurrence. TVA subsequently summarized its plans for recovery of BF1 in a letter dated December 13, 2002 (supplemented by letters dated February 28 and June 11, 2003), after the TVA Board of Directors approved the restart effort for Unit 1 in May 2002. In these letters, TVA described its proposed regulatory framework for the restart of BF1. The regulatory framework is based on the regulatory requirements, corrective actions, Special Programs, commitments, technical specification (TS) improvements, and TVA's internally identified deficiencies and concerns that were resolved prior to Units 2 and 3 restarts in 1991 and 1995, respectively. Prior to TVAs commencement of recovery activities, BF1 had been maintained in a defueled lay-up condition since 1985. In the Regulatory Framework letters, TVA identified 18 license amendments, 19 Generic Letters, 15 Bulletins, 11 Three Mile Island (TMI) action items, and 27 Special Programs for closeout. Some of these items required revisions to the licensing or design bases, while others needed confirmation of adequate implementation of programs or modifications to the plant in support of restart. In a letter dated August 14, 2003, the NRC staff provided an assessment accepting TVA's proposed regulatory framework.
To address the conduct of inspection activities and outline the NRC's criteria and process for determining the readiness for BF1 to restart, the NRC issued Inspection Manual Chapter (IMC) 2509, "Browns Ferry Unit 1 Restart Project Inspection Program" in September 2003. IMC 2509 provided for the establishment of the BF1 Restart Oversight Panel to monitor NRC activities.
IMC 2509 also provided guidance for assessing the readiness of the unit to transition from IMC 2509 oversight to the Reactor Oversight Process (ROP).
P. Swafford 2
The staffs review for BF1 restart included review and revision of the licensing and design basis; inspection of the plant hardware modifications, operations, and procedures; and the completion of an Operational Readiness Assessment Team (ORAT) inspection.
As part of its licensing efforts, the NRC staff conducted regulatory reviews of a number of licensing actions, including Special Programs, Unresolved Safety Issues, TMI Action Items, responses to Generic Communications, and restart commitments required for closeout. The NRC also reviewed and approved several revisions to the design and licensing basis needed to support restart. These items were identified in the regulatory framework letters. The NRC staff completed a series of licensing activities, including four onsite audits, 12 relief requests, 2 exemptions, and over 18 license amendments. As stated in the associated safety evaluations, the NRC staff found that TVAs activities associated with the approved licensing and design changes will be conducted in compliance with the Commission's rules and regulations, and will provide adequate protection to the health and safety of the public.
As part of its inspection program, the NRC staff reviewed TVA programs and plant activities related to the recovery of BF1. These activities included replacement, renovation, and removal of equipment and a review of plant programs, process and training of plant personnel. The NRC inspections of structural, electrical, mechanical and fire protection modifications have resulted in satisfactory findings. Onsite monitoring and review determined that activities involving replacement, renovation, and removal of equipment were satisfactorily conducted so as to maintain adequate nuclear and radiological safety. The NRC staff performed a review to verify the implementation of the licensee's design control programs, the installation and testing of modifications for Special Programs listed in the licensee's Nuclear Performance Plan, and the completion of required actions for outstanding generic communications issues.
In addition, the NRC conducted an Operational Readiness Assessment Team inspection on April 23-28, 2007 to assess management controls, implementation of site programs and personnel readiness to support safe restart and operation of Unit 1. The purpose of this inspection was to focus on the effectiveness of licensee management oversight, safety-significant activities, operator training and experience, corrective action programs, the maintenance program, operator response to annunciators and general plant conditions impacting safety, and the readiness to support three-unit operations. As described in a public meeting held on May 2, 2007 at the Browns Ferry site, the ORAT concluded that site programs, personnel and procedures were adequate for restart of Unit 1 and three unit power operations.
On May 1, 2007, the Director of NRR and I were briefed by the BF1 Restart Oversight Panel on the status of BF1 activities. Subsequently, we received the Panels written recommendation by memorandum dated May 14, 2007. The Panel confirmed that all NRC open items had been addressed and verified the closure of the TVA open items as documented in the licensees May 12, 2007 letter. In addition, the Panel communicated its efforts during the BF1 restart oversight to various stakeholders by holding public meetings of the Restart Oversight Panel, through information provided on the NRCs BF1 website, and through documents which can be found in the NRCs Public Document Room website and letters found in the NRC Public Document Room. On the basis of its review of the staffs licensing and inspection efforts and its review of the licensees recovery efforts, the Panel recommended authorization for Unit 1 restart.
Again, based on consideration of the above factors and having consulted with the Director of the Office of NRR and the EDO, I authorize TVA to restart Browns Ferry Nuclear Plant Unit 1.
P. Swafford 3
I understand that some additional work activities to ready Unit 1 for restart are ongoing. The NRC resident inspectors at the site will continue to observe these activities and the Commission will be kept informed of your progress. In addition, the NRC will conduct detailed inspection of your restart and power ascension activities.
Enclosed is the Inspection Plan and Schedule (IP&S) report which provides a record of the restart issues and documents closure of those issues. Consistent with IMC 2509, the Restart Oversight Panel reviewed TVA's plans for post-restart activities to ensure their acceptability and to plan for appropriate NRC oversight. Those items which are planned to be inspected after restart are indicated as post-restart items. The Panel determined that BF1 would receive NRC oversight using the Reactor Oversight Program (ROP) in four of seven cornerstones of safety.
In separate correspondence, the NRC will provide a plan for transition to the ROP of the three remaining ROP Cornerstones. Additionally, an update to the IP&S report will be issued upon completion of post-restart issues.
In accordance with 10 CFR 2.390 of the NRC's "Rules of Practice," a copy of this letter and its enclosure will be available electronically for inspection in the NRC Public Document Room or from the Publicly Available Records (PARS) component of NRCs document system (ADAMS).
ADAMS is accessible from the NRC Web site at http://www.nrc.gov/reading-rm/adams.html the Public Electronic Reading Room).
Sincerely,
/Victor M. McCree RA for/
William D. Travers Regional Administrator Docket No.: 50-259 License No.: DPR-33
Enclosure:
Inspection Plan and Schedule Report cc w/encl: (See page 4)
OFFICE RII:DRP RII:DRP RII:DRS NRR NRR RII:ORA RII:ORA SIGNATURE TXN /RA/
MTW /RA/
JWS /RA/
/TJM RA for/
JED /via email/
VMM /RA/
/VMM RA for/
NAME TNazario MWidmann JShea CHaney JDyer VMcCree WTravers DATE 05/14/2007 05/14/2007 05/14/2007 05/07/2007 05/08/2007 05/15/2007 05/15/2007 E-MAIL COPY?
YES NO YES NO YES NO YES NO YES NO YES NO YES NO
P. Swafford 4
cc w/encl:
Ashok S. Bhatnagar Senior Vice President Nuclear Operations Tennessee Valley Authority Electronic Mail Distribution Larry S. Bryant, Vice President Nuclear Engineering &
Technical Services Tennessee Valley Authority Electronic Mail Distribution Brian O'Grady Site Vice President Browns Ferry Nuclear Plant Tennessee Valley Authority Electronic Mail Distribution Preston D. Swafford Senior Vice President Nuclear Support Tennessee Valley Authority Electronic Mail Distribution General Counsel Tennessee Valley Authority Electronic Mail Distribution John C. Fornicola, General Manager Nuclear Assurance Tennessee Valley Authority Electronic Mail Distribution Robert G. Jones, Acting Plant Manager Browns Ferry Nuclear Plant Tennessee Valley Authority Electronic Mail Distribution Robert H. Bryan, Jr., General Manager Licensing & Industry Affairs Tennessee Valley Authority Electronic Mail Distribution William D. Crouch, Manager Licensing and Industry Affairs Browns Ferry Nuclear Plant Tennessee Valley Authority Electronic Mail Distribution Beth A. Wetzel, Manager Corporate Nuclear Licensing and Industry Affairs Tennessee Valley Authority 4X Blue Ridge 1101 Market Street Chattanooga, TN 37402-2801 State Health Officer Alabama Dept. of Public Health RSA Tower - Administration Suite 1552 P. O. Box 303017 Montgomery, AL 36130-3017 Chairman Limestone County Commission 310 West Washington Street Athens, AL 35611 Masoud Bajestani, Vice President Browns Ferry Unit 1 Restart Browns Ferry Nuclear Plant Tennessee Valley Authority P. O. Box 2000 Decatur, AL 35609 Robert G. Jones, General Manager Browns Ferry Site Operations Browns Ferry Nuclear Plant Tennessee Valley Authority P. O. Box 2000 Decatur, AL 35609 Distribution w/encl: (See page 5)
P. Swafford 5
Letter to Preston D. Swafford from William D. Travers dated May 15, 2007
SUBJECT:
BROWNS FERRY NUCLEAR PLANT, UNIT 1 - AUTHORIZATION TO RESTART - DOCKET NO. 50-259 Distribution w/encl:
E. Brown, NRR L. Raghavan, NRR C. Evans, RII EICS L. Slack, RII EICS L. Mellen, RII OE Mail RIDSNRRDIRS PUBLIC E-Mail Distribution ACRS PMNS Region II Administrators Secretaries DRP Division Secretary Region II Division Directors and Deputies J. Dyer, NRR C. Evans, Regional Counsel R. Trojanowski, Region II State Liaison Officer K. Clark, Region II Public Affairs Officers R. Hannah, Region II Public Affairs Officer J. Coleman, Region II Information Resource Branch Chief Region II Receptionist S. Campbell, Region II Regional Coordinator OEDO M. Chernoff, NRR E. Brown, NRR L. Raghavan, NRR Headquarters Operations Officer RIDSNRRDIPMLIPB PUBLIC C. Haney, NRR M. Lesser, RII J. Shea, RII L. Mellen, RII T. Nazario, RII T. McGinty, NRR W. Bearden, RII T. Ross, RII C. Stancil, RII C. Tucci, NRR U. Shoop, EDO D. Decker, OCA R. Virgilio, FSME S. Smith, FSME
Browns Ferry Unit 1 Restart Inspection Plan and Schedule (IP&S) Report In accordance with MC 2509, the NRC staff has developed IP&S which collects and provides inspection requirements for areas that comprise the BF1 Restart Project Inspection Program. This IP&S tracking tool identifies the appropriate inspection procedures or equivalent criteria to review the licensee's restart activities and to implement inspections. The tracking tool provides a means for tracking open items, allows for generating reports to support any interface with stakeholders, the Commission, and other agencies, and provides cross-references between the items tracked and applicable inspection reports. IP&S also allows for rescheduling of inspections to accommodate licensee schedule changes and additional inspections that may be identified by Region II or by the BF1 Restart Oversight Panel..
Browns Ferry Units 1 (BF1), 2 (BF2), and 3 (BF3) were voluntarily shutdown by the Tennessee Valley Authority (TVA) in March 1985 for management and regulatory issues. TVA committed to obtain NRC approval prior to the restart of any of the Browns Ferry units. TVA submitted the Browns Ferry Nuclear Performance Plan, Volume 3, in August 1986, outlining the steps needed to recover the Browns Ferry units. NRC issued NUREG-1232, Volume 3, and its supplements, concluding that TVA's actions acceptably addressed Browns Ferry Nuclear Plant deficiencies. TVA obtained NRC permission to restart BF2 in 1991 and BF3 in 1995. In 2002, TVA commenced a 5-year program to recover BF1. Once BF1's startup program is completed, all three units will be similar in their respective plant configurations, and will have implemented corrective actions for outstanding regulatory and generic safety issues.
A Restart Oversight Panel, consisting of participants from both Region II and NRR, has been established in accordance with MC 2509. This panel decides whether the required corrective actions and performance improvement changes have been implemented successfully by the licensee so that BF1 meets the relevant regulatory requirements and can be safely operated. The actual decision to permit the licensee restart to BF1 will be made by the Regional Administrator of Region II with the concurrence of the Director, Office of Nuclear Reactor Regulation (NRR) based on a written recommendation of the Restart Oversight Panel. The panel will also review the readiness of BF1 to be placed under the NRC's normal Reactor Oversight Process (ROP). The decision to permit BF1 to transition into the full oversight of the ROP will be made by the Regional Administrator of Region II with the concurrence of the Director, Office of NRR, based on a written recommendation from the Restart Oversight Panel.
Issues or activities are considered closed in IP&S when the following three criteria have been met: 1) TVA has reviewed and closed the issue or activity in their quarterly update submitted to the NRC, 2) The issue or activity has been reviewed and/or an inspection has been completed by the NRC and an associated inspection report (IR) has been issued, and 3) The BF1 Restart Oversight Panel has been briefed or reviewed available documentation to satisfy the two aforementioned criteria to permit closure of the item.
The attached IP&S report includes open and closed items as discussed above. Documents associated with the NRC oversight of the BF1 Recovery can be found on the NRCs website at http://www.nrc.gov/NRR/OVERSIGHT/ASSESS/bf1-recovery.html.
NRC Inspection Manual Chapter (MC) 2509, Browns Ferry Unit 1 Restart Project Inspection Program, establishes the policy for the BF1 Restart Project inspection program covering BF1's renovation, and restart testing including power ascension. Inspection Procedures (IPs) or Technical Instructions (TIs), documented in Region II's inspection plan and schedule (IP&S), will provide inspection requirements for these main inspection areas that comprise the BF1 Restart Project Inspection Program.
Monday, May 14, 2007 Page 1 of 43 Enclosure
Issue/Activity Description Inspection Procedure(s)
Inspection Report(s)
Cornerstone(s)
Type of Issue/ Activity IP&S ID Number Status 1
Cable Ampacity SP CLOSED BF1-37550 2004-007 2006-009 Mitigating Systems Initiating Events Items numbered 1-108 constitute a basis for Restart as identified in NRC Regulatory Framework Letter dated August 14, 2003 and should be evaluated for closure prior to Restart.
2 Cable Installation/ Cable Separation issues SP CLOSED BF1-37550 51053 37551 2004-007 2004-009 2005-008 2005-009 2006-006 2006-007 2006-012 2006-009 Mitigating Systems Initiating Events 2007-009 3
Cable Splices SP CLOSED BF1-51053 37550 2004-008 2005-008 2006-007 Mitigating Systems Initiating Events 4
Cable Tray Supports SP CLOSED BF1-37551 62002 2003-010 2004-006 2005-008 Mitigating Systems Initiating Events Monday, May 14, 2007 Page 2 of 43 Enclosure
Issue/Activity Description Inspection Procedure(s)
Inspection Report(s)
Cornerstone(s)
Type of Issue/ Activity IP&S ID Number Status 5
Component and Piece Part Qualification SP CLOSED BF1-37550 2006-009 Mitigating Systems Initiating Events Barrier Integrity 6
Conduit Supports SP CLOSED BF1-37551 2004-006 2005-008 Mitigating Systems Initiating Events 7
Configuration Management/ Design Baseline SP CLOSED BF1-37551 2005-008 Mitigating Systems Initiating Events Barrier Integrity 8
Containment Coatings SP CLOSED BF1-37550 62002 2004-007 2004-008 2005-006 2006-009 Mitigating Systems Barrier Integrity Monday, May 14, 2007 Page 3 of 43 Enclosure
Issue/Activity Description Inspection Procedure(s)
Inspection Report(s)
Cornerstone(s)
Type of Issue/ Activity IP&S ID Number Status 9
Control Rod Drive insert/withdrawal piping SP CLOSED BF1-37551 2004-007 2004-008 2005-008 2005-009 2006-006 Mitigating Systems Initiating Events 10 Design Calc Review SP CLOSED BF1-37551 2005-008 Mitigating Systems Initiating Events Barrier Integrity 11 Environmental Qualification SP CLOSED BF1-37550 2003-010 2004-008 2005-008 2006-009 Mitigating Systems Initiating Events 12 Fire Protection /
10CFR50, Appendix R SP CLOSED BF1-37550 64704 37551 2004-009 2005-016 2006-012 2007-009 Mitigating Systems Initiating Events Barrier Integrity Monday, May 14, 2007 Page 4 of 43 Enclosure
Issue/Activity Description Inspection Procedure(s)
Inspection Report(s)
Cornerstone(s)
Type of Issue/ Activity IP&S ID Number Status 13 Flexible Conduits SP CLOSED BF1-37550 2004-007 2004-009 2006-006 Mitigating Systems Initiating Events 14 Fuses SP CLOSED BF1-37550 51053 2004-008 2005-008 2006-007 Mitigating Systems Initiating Events 15 HVAC Duct Supports SP CLOSED BF1-37550 50100 2006-008 Mitigating Systems 16 Instrument Sensing Lines SP CLOSED BF1-37550 2006-007 2006-009 Mitigating Systems Initiating Events Monday, May 14, 2007 Page 5 of 43 Enclosure
Issue/Activity Description Inspection Procedure(s)
Inspection Report(s)
Cornerstone(s)
Type of Issue/ Activity IP&S ID Number Status 17 Instrument Tubing SP CLOSED BF1-37550 37551 2005-008 2006-007 2006-008 Mitigating Systems Initiating Events 18 Intergranular Stress Corrosion Cracking (IGSCC)
SP CLOSED BF1-37551 55050 2003-009 2003-010 2004-006 2004-007 2004-009 2005-008 Barrier Integrity 19 Large Bore Piping Supports SP CLOSED BF1-50090 2003-009 2005-006 2005-008 2005-009 2006-006 2006-007 2006-009 Mitigating Systems Barrier Integrity 20 Long Term Torus Integrity Program SP CLOSED BF1-37550 37551 62002 50090 2003-009 2003-010 2004-007 2004-009 2004-011 2006-006 2006-007 2006-009 Mitigating Systems Barrier Integrity Monday, May 14, 2007 Page 6 of 43 Enclosure
Issue/Activity Description Inspection Procedure(s)
Inspection Report(s)
Cornerstone(s)
Type of Issue/ Activity IP&S ID Number Status 21 Drywell Steel Platforms and Upper drywell platforms SP CLOSED BF1-37550 37551 62002 2003-009 2004-007 2005-008 Mitigating Systems Barrier Integrity 22 Misc Steel Frames SP CLOSED BF1-37551 2003-009 2006-006 Mitigating Systems Barrier Integrity 23 Moderate Energy Line Break (MELB)
SP CLOSED BF1-37550 2006-007 Barrier Integrity 24 Platform Thermal Growth SP CLOSED BF1-37551 2003-009 2005-008 2006-006 Mitigating Systems Barrier Integrity Monday, May 14, 2007 Page 7 of 43 Enclosure
Issue/Activity Description Inspection Procedure(s)
Inspection Report(s)
Cornerstone(s)
Type of Issue/ Activity IP&S ID Number Status Item #25, Probabilistic Safety Assessment (PSA) has been updated to "Not Required" based on document reviews, including NRC staff verification that commitments pertaining to PSA had been previously addressed. The Restart Oversight Panel determined that TVA resolved the PSA issue during Unit 3 restart with the submittal of the Browns Ferry Multi-Unit PSA and dependency matrices, as stated in TVA's Regulatory Framework letter dated December 13, 2002. Furthermore, NRC Regulatory Framework letter dated August 13, 2003 did not identify PSA as a special program.
25 Probabilistic Safety Assessment (PSA)
SP NOT REQUIRED BF1-93804 Mitigating Systems Initiating Events Barrier Integrity 26 Q List SP CLOSED BF1-37550 2006-007 Mitigating Systems Initiating Events Barrier Integrity 27 Restart Test Program (RTP)
SP CLOSED BF1-37551 37550 35301 70315 70301 2005-006 2005-007 2005-008 2005-009 2006-006 2006-007 2006-008 2006-009 Mitigating Systems Initiating Events Barrier Integrity 2007-009 28 Seismic Class II Over I /
Spatial Systems Interactions and Water Spray SP CLOSED BF1-37551 2005-008 Mitigating Systems Initiating Events Barrier Integrity Monday, May 14, 2007 Page 8 of 43 Enclosure
Issue/Activity Description Inspection Procedure(s)
Inspection Report(s)
Cornerstone(s)
Type of Issue/ Activity IP&S ID Number Status 29 Small Bore Piping /
Supports SP CLOSED BF1-37550 37551 2005-008 2006-007 2006-008 Mitigating Systems Initiating Events 30 Thermal Overloads SP CLOSED BF1-37550 51053 2004-008 2005-008 2006-007 Mitigating Systems Initiating Events 31 BU 79-02 Pipe Support Plate Designs Using Concrete Expansion Anchor Bolts GEN CLOSED BF1-37550 2006-009 Mitigating Systems Initiating Events 32 BU 79-12 Short Period Scrams at BWR Facilities GEN CLOSED BF1-92701 2006-007 Mitigating Systems Initiating Events Monday, May 14, 2007 Page 9 of 43 Enclosure
Issue/Activity Description Inspection Procedure(s)
Inspection Report(s)
Cornerstone(s)
Type of Issue/ Activity IP&S ID Number Status 33 BU 79-14 Seismic Analysis for As-Built Safety Related Piping Systems GEN CLOSED BF1-37550 37551 2006-009 Mitigating Systems Barrier Integrity 34 BU 80-06 Engineered Safety Feature Reset Controls GEN CLOSED BF1-92701 2006-008 Mitigating Systems Barrier Integrity 35 BU 84-02 Failure of GE type HFA Relays in use in class 1E Safety Systems GEN CLOSED BF1-92701 2004-009 Mitigating Systems 36 BU 86-02 Static "O" Ring Differential Pressure Switches GEN CLOSED BF1-92701 2005-006 Mitigating Systems Monday, May 14, 2007 Page 10 of 43 Enclosure
Issue/Activity Description Inspection Procedure(s)
Inspection Report(s)
Cornerstone(s)
Type of Issue/ Activity IP&S ID Number Status 37 BU 88-03 Inadequate Latch Engagement in HFA Type Relays Manufactured by GE GEN CLOSED BF1-92701 2004-009 Mitigating Systems 38 BU 88-04 Potential Safety Related Pump Loss GEN CLOSED BF1-92701 2004-009 Mitigating Systems 39 BU 88-07 Power Oscillation in Boiling Water Reactors GEN CLOSED BF1-92701 2006-007 Initiating Events Barrier Integrity 40 BU 88-10 Nonconforming Molded-Case Circuit Breakers GEN CLOSED BF1-92701 2005-009 Mitigating Systems Monday, May 14, 2007 Page 11 of 43 Enclosure
Issue/Activity Description Inspection Procedure(s)
Inspection Report(s)
Cornerstone(s)
Type of Issue/ Activity IP&S ID Number Status 41 BU 90-01 Loss of Fill Oil in Rosemount Transmitters GEN CLOSED BF1-92701 2005-009 Mitigating Systems 42 BU 93-02 Debris Plugging of Emergency Core Cooling Suction Strainers GEN CLOSED BF1-92701 2006-006 2006-008 Barrier Integrity 43 BU 93-03 Resolution of Issues Related to Reactor Vessel Water Level Instruments in BWR's GEN CLOSED BF1-92701 2006-009 Mitigating Systems 44 BU 95-02 Unexpected Clogging of a RHR Pump Strainer While Operating in Suppression Pool Cooling Mode GEN CLOSED BF1-92701 2006-006 Mitigating Systems Barrier Integrity Monday, May 14, 2007 Page 12 of 43 Enclosure
Issue/Activity Description Inspection Procedure(s)
Inspection Report(s)
Cornerstone(s)
Type of Issue/ Activity IP&S ID Number Status 45 BU 96-03 Potential Plugging of Emergency Core Cooling Suction Strainers by Debris in Boiling Water Reactors GEN CLOSED BF1-92701 2006-006 2006-009 Mitigating Systems Barrier Integrity 46 GL 82-33 Instumentation to Follow the Course of an Accident - R.G. 1.97 GEN CLOSED BF1-92701 2005-007 Mitigating Systems 47 GL 83-08 Modification of Vacuum Breakers on Mark 1 Containments GEN CLOSED BF1-92701 2005-006 Barrier Integrity 48 GL 83-28 Salem ATWS -
Item 1.2 Trip Review -
Item 4.5.2 Periodic On-Line Testing - Item 4.5.3 Intervals for On-Line Testing GEN CLOSED BF1-92701 2006-007 Mitigating Systems Initiating Events Monday, May 14, 2007 Page 13 of 43 Enclosure
Issue/Activity Description Inspection Procedure(s)
Inspection Report(s)
Cornerstone(s)
Type of Issue/ Activity IP&S ID Number Status 49 GL 87-02 Verification of Seismic Adequacy of Mechanical and Electrical Equipment in Operating Reactors GEN CLOSED BF1-92701 2004-006 2006-006 2007-009 Mitigating Systems Barrier Integrity 50 GL 88-01 NRC Position on IGSCC in BWR Austenitic Stainless Steel Piping GEN CLOSED BF1-92701 2005-008 2006-006 2006-007 Barrier Integrity 51 GL 88-11 Radiation Embrittlement of Reactor Vessel Materials and its Impact on Plant Operations GEN CLOSED BF1-92701 2006-007 Barrier Integrity 52 GL 88-14 Instrument Air Supply System Problems Affecting Safety Related Equipment GEN CLOSED BF1-92701 2005-008 Mitigating Systems Initiating Events Monday, May 14, 2007 Page 14 of 43 Enclosure
Issue/Activity Description Inspection Procedure(s)
Inspection Report(s)
Cornerstone(s)
Type of Issue/ Activity IP&S ID Number Status 53 GL 88-20 Individual Plant Examination and Supplement 4, Individual Plant Examination of External Events for Severe Accident Vulnerabilities GEN NOT REQUIRED BF1-93804 Mitigating Systems Initiating Events Barrier Integrity 54 GL 89-06 Safety Parameter Display System GEN CLOSED BF1-92701 2006-007 Mitigating Systems Barrier Integrity 55 GL 89-08 Erosion/Corrosion -
Induced Pipe Wall Thinning GEN CLOSED BF1-92701 2005-009 Barrier Integrity 56 GL 89-10 Safety-Related Motor-Operated Valve Testing and Surveillance GEN CLOSED BF1-37550 2004-009 2006-009 Mitigating Systems Monday, May 14, 2007 Page 15 of 43 Enclosure
Issue/Activity Description Inspection Procedure(s)
Inspection Report(s)
Cornerstone(s)
Type of Issue/ Activity IP&S ID Number Status 57 GL 89-13 Service Water System Problems Affecting Safety Related equipment GEN CLOSED BF1-92701 2005-009 2006-007 Mitigating Systems Barrier Integrity 58 GL 89-16 Installation of a Hardened Wetwell Vent GEN CLOSED BF1-92701 2005-006 Barrier Integrity 59 GL 92-01 Reactor Vessel Structural Integrity GEN CLOSED BF1-55100 37550 2006-007 Barrier Integrity 60 GL 92-04 Resolution of the Issues Related to Reactor Vessel Water Level Instrumentation in BWRs.
GEN CLOSED BF1-37550 37551 2006-009 Barrier Integrity Monday, May 14, 2007 Page 16 of 43 Enclosure
Issue/Activity Description Inspection Procedure(s)
Inspection Report(s)
Cornerstone(s)
Type of Issue/ Activity IP&S ID Number Status 61 GL 94-02 Long-Term Solutions and Upgrade of Interim Operating Recommendations for Thermal-Hydraulic Instabilities in BWRs GEN CLOSED BF1-92701 2006-007 Mitigating Systems Initiating Events Barrier Integrity 62 GL 94-03 Intergranular Stress Corrosion Cracking of Core Shrouds in BWR's GEN CLOSED BF1-92701 2005-008 Barrier Integrity 63 GL 95-07 Pressure Locking and Thermal Binding of Safety-Related and Power-Operated Gate Valves GEN CLOSED BF1-37550 37551 2006-006 Mitigating Systems 64 GL 96-01 Testing of Safety-Related Logic Circuits GEN CLOSED BF1-37550 2006-009 Mitigating Systems Monday, May 14, 2007 Page 17 of 43 Enclosure
Issue/Activity Description Inspection Procedure(s)
Inspection Report(s)
Cornerstone(s)
Type of Issue/ Activity IP&S ID Number Status 65 GL 96-05 Periodic Verification of Design Basis Capability of Motor Operated Valves GEN CLOSED BF1-92701 2005-009 Mitigating Systems 66 GL 96-06 Assurance of Equipment Operability and Containment Integrity During Design Basis Accident Conditions GEN CLOSED BF1-92701 2005-008 Mitigating Systems Barrier Integrity 67 GL 97-04 Assurance of Sufficient Net Positive Suction for Emergency Core Cooling and Containment Heat Removal Pumps GEN CLOSED BF1-92701 2006-006 2006-009 Mitigating Systems Barrier Integrity 68 GL 98-01 Readiness of Computer Systems at Nuclear Power Plants GEN CLOSED BF1-92701 2005-006 Mitigating Systems Monday, May 14, 2007 Page 18 of 43 Enclosure
Issue/Activity Description Inspection Procedure(s)
Inspection Report(s)
Cornerstone(s)
Type of Issue/ Activity IP&S ID Number Status 69 GL 98-04 Potential for Degradation of the ECCS and Containment Spray System After a LOCA because of Construction and Protective Coating Deficiencies and Foreign Material in Containment GEN CLOSED BF1-37550 37551 2006-006 2006-008 Mitigating Systems Barrier Integrity 70 Control Room Design Review TMI CLOSED BF1-92701 2006-007 Mitigating Systems Initiating Events 71 Safety Parameter Display Console TMI CLOSED BF1-92701 2006-007 Mitigating Systems Initiating Events Barrier Integrity 72 Post-Accident Sampling System TMI CLOSED BF1-92701 2006-006 Barrier Integrity Monday, May 14, 2007 Page 19 of 43 Enclosure
Issue/Activity Description Inspection Procedure(s)
Inspection Report(s)
Cornerstone(s)
Type of Issue/ Activity IP&S ID Number Status 73 Containment Isolation Dependability -
Implement Diverse Isolation, containment purge valves TMI CLOSED BF1-37550 2007-009 Mitigating Systems Barrier Integrity 74 Accident - Monitoring -
Containment High Range Radiation TMI CLOSED BF1-92701 2006-006 Mitigating Systems Barrier Integrity 75 Accident Monitoring -
Containment Pressure TMI CLOSED BF1-92701 2005-006 Mitigating Systems Barrier Integrity 76 Accident - Monitoring -
Containment Water Level TMI CLOSED BF1-92701 2005-006 Mitigating Systems Barrier Integrity Monday, May 14, 2007 Page 20 of 43 Enclosure
Issue/Activity Description Inspection Procedure(s)
Inspection Report(s)
Cornerstone(s)
Type of Issue/ Activity IP&S ID Number Status 77 (Generic Letter 84-23)
Insturmentation for Detection of Inadequate Core Cooling TMI CLOSED BF1-92701 2005-007 Mitigating Systems Barrier Integrity 78 HPCI/RCIC Initiation Levels TMI CLOSED BF1-92701 2005-007 Mitigating Systems 79 ADS Actuation Modifications TMI CLOSED BF1-92701 2005-007 Mitigating Systems Barrier Integrity 80 Common reference level for BWR TMI CLOSED BF1-92701 2005-008 Mitigating Systems Monday, May 14, 2007 Page 21 of 43 Enclosure
Issue/Activity Description Inspection Procedure(s)
Inspection Report(s)
Cornerstone(s)
Type of Issue/ Activity IP&S ID Number Status 81 Qualification of ADS Accumulators TMI CLOSED BF1-92701 2005-007 Mitigating Systems Barrier Integrity 82 MPA-B011 Flood of equipment important to safety MPA CLOSED BF1-92701 2006-007 Mitigating Systems Initiating Events 83 MPA-B041 Fire Protection Final TS (including SER Supplement)
MPA CLOSED BF1-92701 2006-007 Mitigating Systems Initiating Events 84 MPA-C002 BWR recirculation pump trip (ATWS)
MPA CLOSED BF1-92701 2006-007 Mitigating Systems Initiating Events Monday, May 14, 2007 Page 22 of 43 Enclosure
Issue/Activity Description Inspection Procedure(s)
Inspection Report(s)
Cornerstone(s)
Type of Issue/ Activity IP&S ID Number Status 85 TI 2500/20 - Inspection to determine compliance with ATWS Rule 10CFR 50.62 TI CLOSED BF1-92701 2006-007 Mitigating Systems Initiating Events 86 TI 2515/111 EDSFI Followup TI CLOSED BF1-92701 93811 TI 2515/111 2006-008 Mitigating Systems Initiating Events 87 TI 2515/154 Spent Fuel Material Control and Accountability TI CLOSED BF1-92701 2004-008 Initiating Events Barrier Integrity 88 TI 2515/156 Offsite Power System Readiness TI CLOSED BF1-92701 2004-008 Mitigating Systems Initiating Events Monday, May 14, 2007 Page 23 of 43 Enclosure
Issue/Activity Description Inspection Procedure(s)
Inspection Report(s)
Cornerstone(s)
Type of Issue/ Activity IP&S ID Number Status 89 TI 2515/157 Mark I and II Containment Operations TI CLOSED BF1-37550 37551 Barrier Integrity 90 USI A-7 Mark 1 Long-Term Program, NUREG-0661, Supplement 1 MPA CLOSED BF1-92701 2006-007 Barrier Integrity 91 USI A-9 ATWS MPA CLOSED BF1-92701 2006-007 Mitigating Systems Initiating Events 92 USI A-24 Qualification of Class 1E Safety-Related Equipment MPA CLOSED BF1-92701 2006-007 Mitigating Systems Monday, May 14, 2007 Page 24 of 43 Enclosure
Issue/Activity Description Inspection Procedure(s)
Inspection Report(s)
Cornerstone(s)
Type of Issue/ Activity IP&S ID Number Status 93 USI A-26 Reactor Vessel Pressure Transient Protection MPA CLOSED BF1-92701 2006-007 Barrier Integrity 94 USI A-44 Station Blackout MPA CLOSED BF1-37550 37551 2006-009 2007-009 Mitigating Systems Initiating Events 95 USI A-46 Verification of Seismic Adequacy of Mechanical and Electrical Equipment in Operating Reactors MPA CLOSED BF1-92701 2006-006 2007-009 Mitigating Systems 96 USI A-75 MPA-B085, Required actions on Generic Implications of Salem ATWS Events, Section 1.2, Post Trip Review MPA CLOSED BF1-92701 2006-007 Mitigating Systems Initiating Events Monday, May 14, 2007 Page 25 of 43 Enclosure
Issue/Activity Description Inspection Procedure(s)
Inspection Report(s)
Cornerstone(s)
Type of Issue/ Activity IP&S ID Number Status 97 New Simulator qualification/ Fidelity and Operator Staffing-Review licensee's new simulator to support 3 unit operations. Review Licensed Operator Staffing Plans.
MISC NOT REQUIRED BF1-37550 37551 Mitigating Systems Initiating Events 98 Lay-up Inspections MISC CLOSED BF1-92050 2004-006 Mitigating Systems Barrier Integrity 99 In-vessel inspections, core spray, UT-Full RPV internals/weld inspections complete 2005 for 10-yr ISI RWA CLOSED BF1-55050 37550 37551 71111.08 2005-008 2005-009 2006-006 2006-007 Barrier Integrity 100 Operational Readiness Assessment Team inspection (ORAT)
MISC CLOSED BF1-93806 2007-006 Mitigating Systems Initiating Events Barrier Integrity Monday, May 14, 2007 Page 26 of 43 Enclosure
Issue/Activity Description Inspection Procedure(s)
Inspection Report(s)
Cornerstone(s)
Type of Issue/ Activity IP&S ID Number Status 101 Common Accident Signal MISC CLOSED BF1-37551 71111.17 2005-006 Mitigating Systems Initiating Events 102 Extended Power Uprate-Determine scope of needed inspection reviews to support licensing action MISC NOT REQUIRED BF1-37550 37551 Mitigating Systems Initiating Events Barrier Integrity 103 Enhanced Restart Monitoring-Restart Panel to determine duration.
Proposed 24 hr coverage.
MISC NOT REQUIRED BF1-72518 72526 Mitigating Systems Initiating Events Barrier Integrity 104 License Renewal Application-Determine scope of needed inspection reviews to support licensing action LR CLOSED BF1-37550 2007-011 Monday, May 14, 2007 Page 27 of 43 Enclosure
Issue/Activity Description Inspection Procedure(s)
Inspection Report(s)
Cornerstone(s)
Type of Issue/ Activity IP&S ID Number Status 105 Maintenance Rule-U1 to comply with scoping requirements of 50.65(b) for systems required to be operable or TS applicable.
MISC CLOSED BF1-37550 2006-009 Mitigating Systems Barrier Integrity 106 License Amendment 234 Review - Improved Standard TS MISC CLOSED BF1-107 Turbine Building Dynamic Seismic Analysis-Confirm seismic accelerations for Turbine Building MISC CLOSED BF1-37550 37551 2007-009 Mitigating Systems 108 GL 2003-01 Control Room Habitability GEN NOT REQUIRED BF1-37550 2007-009 Mitigating Systems Barrier Integrity Monday, May 14, 2007 Page 28 of 43 Enclosure
Issue/Activity Description Inspection Procedure(s)
Inspection Report(s)
Cornerstone(s)
Type of Issue/ Activity IP&S ID Number Status 109 RCS Pipe Replacement MODs RWA CLOSED BF1-37550 37551 55050 57050 57060 57090 73753 73755 2003-009 2003-011 2004-006 2004-007 2004-008 2004-009 2005-006 2006-006 Mitigating Systems Barrier Integrity 71111.08 The following Items (109 and above) are being tracked for completeness only.
110 Common Accident Signal Logic Changes RWA CLOSED BF1-71111.17 37550 37551 2004-007 2004-008 2004-009 2005-006 2005-007 Mitigating Systems Initiating Events 111 ECCS Systems MODs RWA CLOSED BF1-71111.17 37550 37551 2004-006 2004-007 2004-008 2004-009 2005-006 2005-007 2005-008 2005-009 Mitigating Systems 2006-006 2006-007 112 RHRSW MODs RWA CLOSED BF1-37550 37551 71111.17 2004-006 2005-008 2005-009 2006-007 Mitigating Systems Monday, May 14, 2007 Page 29 of 43 Enclosure
Issue/Activity Description Inspection Procedure(s)
Inspection Report(s)
Cornerstone(s)
Type of Issue/ Activity IP&S ID Number Status 113 Cable Installation Activities RWA CLOSED BF1-37550 37551 2003-011 2005-007 2005-009 2006-006 2006-007 2006-012 2006-009 2007-009 Mitigating Systems 114 EQ MODs RWA CLOSED BF1-35301 37550 37551 2004-009 2005-007 2006-006 2006-009 Mitigating Systems 115 Cable Splices and Terminations RWA CLOSED BF1-37550 37551 2006-007 Mitigating Systems 116 CRDR MODs RWA CLOSED BF1-71111.17 37550 37551 2004-006 2004-009 2005-006 2005-007 2005-008 2005-009 2006-006 2006-007 Mitigating Systems Initiating Events Monday, May 14, 2007 Page 30 of 43 Enclosure
Issue/Activity Description Inspection Procedure(s)
Inspection Report(s)
Cornerstone(s)
Type of Issue/ Activity IP&S ID Number Status 117 Cable Tray and Conduit Modifications RWA CLOSED BF1-62002 71111.17 37550 37551 2003-009 2003-010 2005-008 Mitigating Systems 118 Large Bore Pipe Support MODs RWA CLOSED BF1-35301 37550 37551 2006-009 Mitigating Systems Barrier Integrity 119 Small Bore Pipe Support MODs RWA CLOSED BF1-37551 2005-008 2006-008 Mitigating Systems Barrier Integrity 120 Instrument Sensing Lines MODs RWA CLOSED BF1-35301 37550 37551 2006-008 2006-009 Mitigating Systems Barrier Integrity Monday, May 14, 2007 Page 31 of 43 Enclosure
Issue/Activity Description Inspection Procedure(s)
Inspection Report(s)
Cornerstone(s)
Type of Issue/ Activity IP&S ID Number Status 121 Fire Protection Changes RWA CLOSED BF1-64704 37550 37551 2004-009 2005-016 2006-012 2007-009 Mitigating Systems Initiating Events Barrier Integrity 122 Common Accident Signal Logic Acceptance Test RT CLOSED BF1-37550 37551 92901 2006-008 Mitigating Systems Initiating Events 123 Full ROP Transition Review ROP CLOSED BF1-92701 Mitigating Systems Initiating Events Barrier Integrity 124 Develop Enhanced ROP Baseline Inspection Plan ROP CLOSED BF1-37550 37551 Mitigating Systems Initiating Events Barrier Integrity Monday, May 14, 2007 Page 32 of 43 Enclosure
Issue/Activity Description Inspection Procedure(s)
Inspection Report(s)
Cornerstone(s)
Type of Issue/ Activity IP&S ID Number Status 125 Mitigating Systems Cornerstone Open Items Closeout Inspection ROP CLOSED BF1-37550 37551 2007-009 Mitigating Systems 126 Initiating Events Cornerstone Open Items Closeout Inspection ROP CLOSED BF1-37550 37551 2007-009 Initiating Events 127 Barrier Integrity Cornerstone Open Items Closeout Inspection ROP CLOSED BF1-37550 37551 2007-009 Barrier Integrity 128 Post SPOC II Review -
SLC SPOC CLOSED BF1-37551 2006-008 Mitigating Systems Monday, May 14, 2007 Page 33 of 43 Enclosure
Issue/Activity Description Inspection Procedure(s)
Inspection Report(s)
Cornerstone(s)
Type of Issue/ Activity IP&S ID Number Status 129 Post SPOC II Review -
250 VDC SPOC CLOSED BF1-37551 2006-008 Mitigating Systems 130 Post SPOC II Review -
CS SPOC CLOSED BF1-37551 2006-009 Mitigating Systems 131 Post SPOC II Review -
RHR SPOC CLOSED BF1-37551 2006-009 Mitigating Systems 132 Post SPOC II Review -
RPS SPOC CLOSED BF1-37551 2006-009 Mitigating Systems Monday, May 14, 2007 Page 34 of 43 Enclosure
Issue/Activity Description Inspection Procedure(s)
Inspection Report(s)
Cornerstone(s)
Type of Issue/ Activity IP&S ID Number Status 133 Post SPOC II Review -
RBCCW SPOC CLOSED BF1-37551 2006-009 Mitigating Systems 134 Post SPOC II Review -
CRD SPOC CLOSED BF1-37551 2006-009 Mitigating Systems 135 Post SPOC II Review -
RCIC SPOC CLOSED BF1-37551 2007-009 Mitigating Systems 136 Post SPOC II Review -
HPCI SPOC CLOSED BF1-37551 2007-009 Mitigating Systems Monday, May 14, 2007 Page 35 of 43 Enclosure
Issue/Activity Description Inspection Procedure(s)
Inspection Report(s)
Cornerstone(s)
Type of Issue/ Activity IP&S ID Number Status 137 Post SPOC II Review -
Main Steam SPOC CLOSED BF1-37551 2007-006 Mitigating Systems 138 License Renewal Followup Inspection LR CLOSED BF1-92701 37550 37551 2007-011 Mitigating Systems Barrier Integrity 139 Core Spray Acceptance Test RT CLOSED BF1-37551 2006-008 Mitigating Systems 140 Control Rod Drive Acceptace Test RT CLOSED BF1-37551 2006-009 2007-009 Mitigating Systems Monday, May 14, 2007 Page 36 of 43 Enclosure
Issue/Activity Description Inspection Procedure(s)
Inspection Report(s)
Cornerstone(s)
Type of Issue/ Activity IP&S ID Number Status 141 250 V DC Distribution Acceptance Test RT CLOSED BF1-37551 2006-008 Mitigating Systems 142 Standby Liquid Control System Acceptance Test RT CLOSED BF1-37551 2006-008 Mitigating Systems 143 RHR Acceptance Test RT CLOSED BF1-37551 2006-009 Mitigating Systems 144 Reactor Core Isolation Cooling Acceptance Test RT CLOSED BF1-37551 2006-009 Mitigating Systems Monday, May 14, 2007 Page 37 of 43 Enclosure
Issue/Activity Description Inspection Procedure(s)
Inspection Report(s)
Cornerstone(s)
Type of Issue/ Activity IP&S ID Number Status 145 Reactor Protection Acceptance Test RT CLOSED BF1-37551 2006-009 Mitigating Systems 146 Reactor Building Closed Cooling Water Acceptance Test RT CLOSED BF1-37551 2006-009 Mitigating Systems 147 High Pressure Coolant Injection Acceptance Test RT CLOSED BF1-37551 2007-009 Mitigating Systems 148 Main Steam Acceptance Test RT CLOSED BF1-37551 2007-006 Mitigating Systems Monday, May 14, 2007 Page 38 of 43 Enclosure
Issue/Activity Description Inspection Procedure(s)
Inspection Report(s)
Cornerstone(s)
Type of Issue/ Activity IP&S ID Number Status 149 Diesel Generator Load Acceptance Test RT CLOSED BF1-37551 2006-009 Mitigating Systems 150 480 Volt Shutdown Board Load Shed Logic Acceptance Test RT CLOSED BF1-37551 2006-008 Mitigating Systems 151 ECCS Actuation Acceptance Test RT CLOSED BF1-37551 2006-008 2006-009 Mitigating Systems 152 Refueling and Outage Activities Inspection MISC CLOSED BF1-71111.20 2006-009 2007-009 Mitigating Systems Initiating Events Barrier Integrity Monday, May 14, 2007 Page 39 of 43 Enclosure
Issue/Activity Description Inspection Procedure(s)
Inspection Report(s)
Cornerstone(s)
Type of Issue/ Activity IP&S ID Number Status 153 Fire Protection Walkdown MISC CLOSED BF1-71111.05 2006-004 2006-005 2006-009 Mitigating Systems Initiating Events Barrier Integrity 154 Equipment Alignments CLOSED BF1-71111.04 2006-009 Mitigating Systems 155 Power Ascension Testing PAT OPEN BF1-71111.20 Mitigating Systems Initiating Events Barrier Integrity 156 Self-Assessment MISC OPEN BF1-35301 Monday, May 14, 2007 Page 40 of 43 Enclosure
Issue/Activity Description Inspection Procedure(s)
Inspection Report(s)
Cornerstone(s)
Type of Issue/ Activity IP&S ID Number Status 157 GL 87-02 closeout -
scope of inspections GEN CLOSED BF1-37551 2007-009 158 URI, 06-08-02, Impact of Duct tape on Instrument tubing URI CLOSED BF1-2006-009 159 IFI 95-55-01, Containment Air Monitors IFI CLOSED BF1-92701 2006-009 160 Part 21 on OTEC instruments CLOSED BF1-2006-009 Monday, May 14, 2007 Page 41 of 43 Enclosure
Issue/Activity Description Inspection Procedure(s)
Inspection Report(s)
Cornerstone(s)
Type of Issue/ Activity IP&S ID Number Status 161 Complete Area Turnover for all areas required for Fuel Load AT CLOSED BF1-2006-009 Mitigating Systems Initiating Events Barrier Integrity 162 Complete Area Turnover for all areas required for Mode 2 AT CLOSED BF1-2006-009 2007-009 Mitigating Systems Initiating Events Barrier Integrity 163 URI 06-12-01, Feasibility of local operator actions to achieve safe shutdown URI OPEN BF1-164 URI 06-09-03, Criteria was not adequately defined to ensure divisional separation for cables were maintained URI CLOSED BF1-2007-009 Monday, May 14, 2007 Page 42 of 43 Enclosure
Issue/Activity Description Inspection Procedure(s)
Inspection Report(s)
Cornerstone(s)
Type of Issue/ Activity IP&S ID Number Status LEGEND FOR TYPE FIELD Type Description GEN Generic Communication IFI Inspector Followup Item LA Licensing Action LR License Renewal MISC Miscellaneous NCV Noncited Violation OI Open Item PAT Power Ascension Testing REG Regulatory Issue ROP ROP Transition RT Restart Test RWA Renovation Work Activity SP Special Program SPOC System Pre-Operability Checklist TMI Three Mile Island URI Unresolved Item VIO Violation AT Area Turnover MPA Multi-Plant Action TI Technical Instruction On March 5, 2007 the Panel added a new category in the issue status field. This category is the Not Required category which better clarifies and identifies those items which are not required to be completed prior to restart but will continue to be tracked for completeness. The change is only administrative in nature and does not impact NRCs assessment of Browns Ferry Unit 1 nor NRCs scheduling of resources. The items that were identified as "Not Required" and no longer require completion prior to Restart but will continue to be tracked in IP&S are the following:
Item #25, Probabilistic Safety Assessment (PSA); Item #53, GL 88-20 Individual Plant Examination and Supplement 4, Individual Plant Examination of External Events for Severe Accident Vulnerabilities; Item #97, New Simulator qualification/
Fidelity and Operator Staffing-Review licensee's new simulator to support 3 unit operations; Item #102, Extended Power Uprate-Determine scope of needed inspection reviews to support licensing action; Item #103, Enhanced Restart Monitoring-Restart Panel to determine duration. Proposed 24 hr coverage; Item
- 108, GL 2003-01 Control Room Habitability NOTES Monday, May 14, 2007 Page 43 of 43 Enclosure