IR 05000128/2007201
ML071080007 | |
Person / Time | |
---|---|
Site: | 05000128 |
Issue date: | 04/19/2007 |
From: | Johnny Eads NRC/NRR/ADRA/DPR/PRTB |
To: | Maldanado T Texas A&M Univ |
Eads J, NRR/ADRA/DPR/PRTB, 415-1471 | |
References | |
IR-07-201 | |
Download: ML071080007 (26) | |
Similar Documents at 05000128 | |
---|---|
Category:Inspection Report
MONTHYEARIR 05000128/20232012024-04-22022 April 2024
[Table view]Texas Engineering Experiment Station/Texas A&M University System, Nuclear Science Center – U.S. Nuclear Regulatory Commission Safety Inspection Report No. 05000128/2023201 and Notice of Violation IR 05000128/20232022024-04-11011 April 2024 Texas Engineering Experiment Station Texas A&M University System U.S. NRC Security Inspection Report No. 05000128/2023202 and Notice of Violation - Cover Letter IR 05000128/20222012023-02-0202 February 2023 Tees/Tamu, NSC U.S. NRC Routine Inspection Report No. 050000128/2022201 IR 05000128/20212012022-01-24024 January 2022 Texas Engineering Experiment Station/Texas A&M University System, Nuclear Science Center, U.S. Nuclear Regulatory Commission Routine Inspection Report 050000128/2021201 IR 05000128/20202022021-02-0303 February 2021 Texas Engineering Experiment Station/Texas A&M University System - U.S. Nuclear Regulatory Commission Routine Inspection Report No. 05000128/2020202 IR 05000128/20182012019-01-17017 January 2019 Texas Engineering Experiment Station/Texas A&M University System, Nuclear Science Center - U.S. Nuclear Regulatory Commission Routine Inspection Report No. 50-128/2018-201 (Cover Letter/Enclosure) IR 05000128/20162012017-01-0404 January 2017 Texas A&M University, Texas A&M Engineering Experiment Station NRC Routine Inspection Report 05000128/2016201 IR 05000128/20152032015-12-15015 December 2015 IR 05000128/2015203, November 9-12, 2015, Texas A&M University - Nuclear Regulatory Commission Routine IR 05000128/20152022015-10-22022 October 2015 EA-14-230, Texas A&M University, Notice of Violation and Proposed Imposition of Civil Penalty - $3,500.00 (NRC Inspection Report 50 128/2015-202 and Office of Investigations Report No. 4-2014-010, Texas A&M Nuclear Science Center) ML15232A7472015-09-11011 September 2015 IR 05000128/2015-202 -12/01/14, Texas A&M Nuclear Science Center - NRC Inspection Report 50-128/2015-202 and Results of NRC Office of Investigations Report No. 4-2014-010 IR 05000128/20152012015-04-24024 April 2015 IR 05000128/2015201, March 26, 2015, Texas A&M University, Texas A&M Engineering Experiment Station IR 05000128/20142012014-11-12012 November 2014 Texas A&M Univ., Reply to a Notice of Violation for Inspection Report 05000128/2014-201 IR 05000128/20132012013-12-0505 December 2013 IR 05000128-13-201; 11/04/2013 - 11/07/2013, Texas A&M University Nuclear Science Center Reactor, NRC Routine Inspection Report IR 05000128/20112012011-11-22022 November 2011 IR 05000128-11-201 on October 31 to November 3, 2011 at Texas Engineering and Experiment Station (Texas a & M Triga) - NRC Inspection Report No. 50-128/2011-201 IR 05000128/20102012010-12-16016 December 2010 IR 05000128-10-201 on 11/15/10 - 11/18/2010, Texas Engineering Experiment Station (Texas a & M University), NRC Routine Inspection Report IR 05000128/20102022010-12-13013 December 2010 IR 05000128-10-202, on 11/16/2010 -11/18/2010, Texas Engineering Experiment Station (Texas a & M University), Transmittal Letter to Licensee NRC Security-Related Inspection Report No. 50-128/2010-202 IR 05000128/20072032007-08-10010 August 2007 IR 05000128-07-203, on 07/27/2007 - 07/30/2007, for Texas A&M University - NRC Special Security IR 05000128/20072022007-04-24024 April 2007 Texas A&M University - NRC Security Inspection Report 50-128/2007-202 IR 05000128/20072012007-04-19019 April 2007 IR 05000128-07-201, on April 3-4, 2007, Texas A&M University Nuclear Science Center Reactor Facility IR 05000128/20062022006-08-23023 August 2006 IR 05000128-06-202, on 03/22/2006 - 03/24/2006, Texas A&M University. Cover Letter IR 05000128/20062032006-05-24024 May 2006 Texas Engineering Experiment Station, Reply to Notice of Violation EA-06-113, NRC Special Inspection Report 50-128-06-203 ML0610901882006-05-11011 May 2006 Letter to Dr. Theresa A. Maldonado from Christopher I. Grimes NRC Special Inspection Report No. 50-128/2006-203 and Notice of Violation IR 05000128/20062012006-05-0202 May 2006 IR 05000128-06-201, on March 20 - 24, 2006, Texas A&M University (Texas Engineering Experiment Station), Selected Aspects of the Licensee'S Class II Research Reactor Safety Programs IR 05000128/20032012003-08-19019 August 2003 IR-05000128-03-201, on 06/23-26/03 for Nuclear Science Center Reactor, Regarding Licensee'S Programs Concerning Operations, Emergency Preparedness, Security and Safeguards, and Radiation Protection ML0300207502003-01-15015 January 2003 IR 05000128-02-201, on September 17-20, 2002, Texas A&M Univ, College Station, Tx. Special Reactive Announced Inspection in Response to Declared Unusual Event IR 05000128/19992011999-07-0909 July 1999 Insp Rept 50-128/99-201 on 990608-10.No Violations Noted. Major Areas Inspected:Review of Selected Conditions & Records Since Last Insp,Verification of C/A Previously Committed to by Licensee IR 05000128/19972011998-12-0808 December 1998 Insp Rept 50-128/97-201 on 971103-05 & 981102-05.No Significant Safety Issues Were Identified.Major Areas Inspected:Selected Conditions & Records Since Last Insp, Verification of C/As & Actions Re Reportable Occurences IR 05000128/19970011997-08-11011 August 1997 Ack Receipt of Informing NRC of Steps Taken to Correct Violations Noted in Insp Rept 50-128/97-01 on 970317-21.Revised NOV Re Violation E,Concerning Failure to Survey Encl IR 05000128/19920021993-01-19019 January 1993 Ack Receipt of Informing NRC of Steps Taken to Correct Violations Noted in Insp Rept 50-128/92-02 IR 05000128/19880031988-05-25025 May 1988 Insp Rept 50-128/88-03 on 880411-12.Violation Noted.Major Areas Inspected:Licensee Radiation Protection Program, Radiological Surveys Including Independent Radiation Spectrum Measurements of Reactor Beam Port 1 IR 05000128/19880021988-04-28028 April 1988 Insp Rept 50-128/88-02 on 880405-07.No Violations or Deviations Noted.Major Areas Inspected:Review & Audit, Experiments,Procedures,Organization,Logs & Records,Plant Status,Requalification Program,Surveillance & Site Tour IR 05000128/19880011988-04-15015 April 1988 Summary of 880405 Enforcement Conference W/Licensee in Arlington,Tx Re Violations Noted in Insp Rept 50-128/88-01. NRC Concerns Re Lack of Effective Radiation Protection Program Also Discussed.Attendance List Encl IR 05000128/19870011987-03-0303 March 1987 Insp Rept 50-128/87-01 on 870112-14.Violations Identified: Failure to Evaluate Hazards Involving Irradiation & Handling of Bromine During 861218 Experiment & Failure to Renew Ref Ltr of Agreement on 861231,as Required by Emergency Plan IR 05000128/19860021986-09-0303 September 1986 Insp Rept 50-128/86-02 on 860729-30.No Violation or Deviation Noted.Major Areas Inspected:Logs,Organization, Review & Audit Functions,Requalification Training, Procedures,Surveillance Activities & Experiments IR 05000128/19860061986-08-20020 August 1986 Grants 30-day Extension Until 860922 for Reply to 860722 Notice of Violation & Proposed Imposition of Civil Penalty Re Insp Rept 50-128/86-06 & EA-86-105,per 860811 Request IR 05000128/19860011986-05-0909 May 1986 Reactive Insp Rept 50-128/86-01 on 860505.Violation Noted: Failure to Measure Reactivity Worth of Experiment Before Reactor Operation & to Rept Reactivity Greater than One Dollar Associated w/860310 Event IR 05000128/20020011985-02-28028 February 1985 Lists Observations & Comments from NRC & Eg&G 850128-0201 Audit of Facility Environ Qualification of Equipment.Review Continuing.Evaluation Will Be Included in Sser IR 05000128/19820011982-07-0606 July 1982 IE Insp Rept 50-128/82-01 on 820604.No Noncompliance Noted. Major Areas Inspected:Facts & Circumstances Re Reported Beta/Gamma Radiation Exposure of 180 Rem to Right Hand TLD for Reactor Operator.Max Exposure Approx 2.5 Rem 2024-04-22 Category:Letter MONTHYEARML24214A1612024-08-0707 August 2024
[Table view]Examination Confirmation Letter No. 50-128/OL 25-01, Texas A&M University ML24129A1852024-05-0808 May 2024 Tees - License Management Change for the Reactors IR 05000128/20232012024-04-22022 April 2024 Texas Engineering Experiment Station/Texas A&M University System, Nuclear Science Center – U.S. Nuclear Regulatory Commission Safety Inspection Report No. 05000128/2023201 and Notice of Violation IR 05000128/20232022024-04-11011 April 2024 Texas Engineering Experiment Station Texas A&M University System U.S. NRC Security Inspection Report No. 05000128/2023202 and Notice of Violation - Cover Letter ML23350A0072023-12-16016 December 2023 Texas A&M University Engineering Experiment Station, Nuclear Engineering & Science Center (Tees) Submittal of Revised Emergency Plan ML23198A0122023-12-12012 December 2023 Examination Report Letter No. 50-128/Ol-23-03, Texas A&M University ML23344A0012023-12-10010 December 2023 Texas A&M Univ., License Management Change ML23198A0102023-07-31031 July 2023 Texas A&M University, Examination Confirmation Letter 50-128/OL-23-03 ML23115A0612023-05-0404 May 2023 Examination Report Letter No. 50-128/OL-23-02, Texas A&M University ML23115A0622023-05-0404 May 2023 Examination Result Letter No. 50-128/OL-23-02, Texas A&M University ML23047A4792023-03-0707 March 2023 Examination Confirmation Letter No. 50-128/OL-23-02, Texas A&M University IR 05000128/20222012023-02-0202 February 2023 Tees/Tamu, NSC U.S. NRC Routine Inspection Report No. 050000128/2022201 ML23018A1292023-01-16016 January 2023 Texas Engineering Experiment Station Nuclear Science Center Reactor Self-Report of Radiation Levels Exceeding Regulatory Limits ML22227A1932022-09-0808 September 2022 Examination Confirmation Letter No. 50-128/OL-23-01,Texas A&M University ML22226A0012022-06-24024 June 2022 Texas A&M Univ., License Amendment Request Re Management Change ML22038A9612022-02-11011 February 2022 Examination Confirmation Letter No. 50-128/OL-22-02, Texas A&M University IR 05000128/20212012022-01-24024 January 2022 Texas Engineering Experiment Station/Texas A&M University System, Nuclear Science Center, U.S. Nuclear Regulatory Commission Routine Inspection Report 050000128/2021201 ML21350A4022021-12-16016 December 2021 Examination Report Letter No. 50-128/OL-22-01, Texas A&M University ML21259A2102021-09-17017 September 2021 Texas Engineering Experiment Station/Texas A&M University System Change of Facility Project Manager ML21256A3042021-09-13013 September 2021 Notification of Changes in License Level Personnel for the Texas A&M Experiment Station NSCR (R-83) and the Texas A&M University Agn (R-23) ML21221A1722021-08-23023 August 2021 Examination Confirmation Letter No.50-128/OL-22-01, Texas A&M University ML21146A1922021-07-22022 July 2021 Texas Engineering Experiment Station/Texas A&M University System Issuance of Amendment No. 19 to Renewed Facility Operating License No. R-83 for the Texas Engineering Experiment Station/Texas A&M University System Nuclear Science Center ML21130A5652021-05-17017 May 2021 Acceptance Review of License Amendment Request to Remove License Condition Expiration Date ML21123A2922021-05-0303 May 2021 License Amendment Request for Facility Operating License R-83; Revision of the License Conditions for Removal of the Expiration Date on Possession of the AGN-201M Reactor Fuel ML21039A5302021-02-0808 February 2021 Examination Confirmation Letter No. 50-128/OL-21-01, Texas A&M University (Triga) IR 05000128/20202022021-02-0303 February 2021 Texas Engineering Experiment Station/Texas A&M University System - U.S. Nuclear Regulatory Commission Routine Inspection Report No. 05000128/2020202 ML20295A4242020-11-16016 November 2020 Notification of Mailing Address Change Regarding Submittal of Fingerprint Cards ML20022A3622020-01-22022 January 2020 Reply to a Notice of Violation Inspection Report No. 50-128/2019-201 (License R-83) ML20007E2182019-12-23023 December 2019 Examination Confirmation Letter No. 50-128/OL-20-02, Texas A&M University ML19242E1692019-08-30030 August 2019 Examination Confirmation Letter No. 50-128/OL-20-001, Texas A&M University ML19015A3312019-01-18018 January 2019 Texas Engineering Experiment Station/Texas A&M University System -Change of Facility Project Manager IR 05000128/20182012019-01-17017 January 2019 Texas Engineering Experiment Station/Texas A&M University System, Nuclear Science Center - U.S. Nuclear Regulatory Commission Routine Inspection Report No. 50-128/2018-201 (Cover Letter/Enclosure) ML18355A9192018-12-19019 December 2018 Examination Report No. 50-128/OL-19-01, Texas A&M University ML18243A3052018-08-30030 August 2018 Examination Confirmation Letter No. 50-128/OL-19-01, Texas A&M University ML17331B4472018-01-10010 January 2018 Examination Report No. 50-128/OL-18-01, Texas A&M University ML17255A8422017-09-14014 September 2017 Examination Confirmation Letter No. 50-128/OL-18-01, Texas a & M University ML17067A3612017-03-30030 March 2017 Texas Engineering Experiment Station/Texas A&M University System Nuclear Science Center - Closeout of Generic Letter 2016-01, Monitoring of Neutron Absorbing Materials in Spent Fuel Pools, Docket No. 50-128 (CAC No. A11010) IR 05000128/20162012017-01-0404 January 2017 Texas A&M University, Texas A&M Engineering Experiment Station NRC Routine Inspection Report 05000128/2016201 ML16309A2912016-11-0909 November 2016 Examination Report No 50-128/OL-17-01, Texas A&M University ML16305A1962016-10-31031 October 2016 Texas A&M Triga and Agn Response to Us NRC Generic Letter 2016-01 ML16109A1532016-08-31031 August 2016 Texas Engineering Experiment Station/Texas A&M University System - Issuance of Amendment No. 18 to Renewed Facility Operating License No. R-83 for the Receipt and Possession of the AGN-201M Reactor Fuel ML16222B0232016-08-11011 August 2016 Examination Confirmation Letter, No. 50-128/OL-17-001, Texas A&M University ML16215A5122016-08-0202 August 2016 to License Amendment Request Dated October 14, 2015, Facility License R-83, Docket Number 50-128. (ADAMS Accession No. ML15287A148) ML16132A5162016-05-11011 May 2016 Texas A&M University - Supplement 4 to License Amendment Request Dated October 14, 2015 ML16095A1332016-04-22022 April 2016 Texas Engineering Experiment Station/Texas A&M Univeristy System Nuclear Science Center Reactor - Closure of Confirmatory Action Letter No. NRR-04-011 On Site-Specific Compensatory Measures Implemention Plan ML16117A2622016-04-20020 April 2016 Texas A&M Univ., Submittal of 2015 Annual Operating Report ML16078A3922016-03-18018 March 2016 Texas A&M University - Supplement 3 to License Amendment Request Dated October 14, 2015 ML16075A4092016-03-15015 March 2016 to License Amendment Request Dated October 14, 2015 ML16063A2642016-03-0303 March 2016 Texas A&M Univ. - Supplement to License Amendment Request Dated October 14, 2015 ML15350A0532015-12-23023 December 2015 Examination Results Letter, No. 50-128/OL-016-01, Texas A&M University 2024-08-07 |
Inspection Report - - 2007201 (Security) | |
---|---|
Assessments
|
Text
ril 19, 2007
SUBJECT:
NRC INSPECTION REPORT NO. 50-128/2007-201
Dear Dr. Maldonado:
This letter refers to the inspection conducted on April 3-4, 2007, at the Texas A&M University Nuclear Science Center Reactor Facility. The inspection included a review of activities authorized for your facility. The enclosed report presents the results of that inspection.
Areas examined during the inspection are identified in the report. Within these areas, the inspection consisted of selective examinations of procedures and representative records, interviews with personnel, and observation of activities in progress. Based on the results of this inspection, no safety concerns or noncompliance with U.S. Nuclear Regulatory Commission (NRC) requirements were identified. No response to this letter is required.
In accordance with Section 2.390, Public inspections, exemptions, requests for withholding, of Title 10 of the Code of Federal Regulations, a copy of this letter and its enclosure will be made available electronically for public inspection in the NRC Public Document Room or from the NRCs Agencywide Documents Access and Management System (ADAMS), accessible from the NRC Web site at http://www.nrc.gov/reading-rm/adams.html.
Should you have any questions concerning this inspection, please contact Mr. Kevin M. Witt at (301) 415-4075.
Sincerely,
/RA/
Johnny Eads, Branch Chief Research and Test Reactors Branch B Division of Policy and Rulemaking Office of Nuclear Reactor Regulation Docket No. 50-128 License No. R-83 Enclosure: NRC Inspection Report No. 50-128/2007-201 cc w/encl: Please see next page
April 19, 2007 Dr. Theresa