December 19, 2018 Dr. Sean McDeavitt, Director Nuclear Science Center Texas A&M University 1095 Nuclear Science Road College Station, TX 77843
SUBJECT:
EXAMINATION REPORT NO. 50-128/OL-19-01, TEXAS A&M UNIVERSITY
Dear Dr. McDeavitt:
During the week of October 15, 2018, the U.S. Nuclear Regulatory Commission (NRC) administered an operator licensing examination at your Texas A&M University research reactor.
The examinations were conducted according to NUREG-1478, "Operator Licensing Examiner Standards for Research and Test Reactors," Revision 2. Examination questions and preliminary findings were discussed with those members of your staff identified in the enclosed report at the conclusion of the examination.
In accordance with Title 10 of the Code of Federal Regulations, Section 2.390, a copy of this letter and the enclosures will be available electronically for public inspection in the NRC Public Document Room or from the Publicly Available Records (PARS) component of NRC's Agencywide Documents Access and Management System (ADAMS). ADAMS is accessible from the NRC Web site at http://www.nrc.gov/reading-rm/adams.html. The NRC is forwarding the individual grades to you in a separate letter which will not be released publicly. Should you have any questions concerning this examination, please contact Mr. John T. Nguyen at (301) 415-4007 or via internet e-mail John.Nguyen@nrc.gov.
Sincerely,
/RA/
Anthony J. Mendiola, Chief Research and Test Reactors Oversight Branch Division of Licensing Projects Office of Nuclear Reactor Regulation Docket No. 50-128
Enclosures:
- 1. Examination Report No. 50-128/OL-19-01
- 2. Written examination cc: w/o enclosures: See next page
ML18355A919 NRR-079 OFFICE NRR/DLP/PROB/CE NRR/DLP/IOLB/OLA NRR/DLP/PROB/BC NAME JNguyen CJRandiki AMendiola DATE 12/10/2018 12/12/2018 12/19/2018
Texas A&M University Docket No. 50-128 cc:
Mayor, City of College Station P.O. Box Drawer 9960 College Station, TX 77840-3575 Governors Budget and Policy Office PO Box 12428 Austin, Texas 78711-2428 Dr. Dimitris C. Lagoudas, Deputy Director Texas A&M University Texas Engineering Experiment Station 241 Zachry Engineering Center College Station, Texas 77843 Mr. Jerry Newhouse, Assistant Director Nuclear Science Center Texas A&M University Texas Engineering Experiment Station 1095 Nuclear Science Road, MS 3575 College Station, Texas 77843 Radiation Program Officer Bureau of Radiation Control Department of State Health Services Division for Regulatory Services 1100 West 49th Street, MC 2828 Austin, TX 78756-3189 Technical Advisor Office of Permitting, Remediation &
Registration Texas Commission on Environmental Quality P.O. Box 13087, MS 122 Austin, TX 78711-3087 Test, Research and Training Reactor Newsletter P.O. Box 118300 University of Florida Gainesville, FL 32611 Mr. Scott Miller, Manager Reactor Operations Texas A&M University Texas Engineering Experiment Station 1095 Nuclear Science Road, MS 3575 College Station, Texas 77843 State Energy Conservation Office Comptroller of Public Accounts P.O. Box 13528 Austin, TX 78711-3528
ENCLOSURE 1 U.S. NUCLEAR REGULATORY COMMISSION OPERATOR LICENSING INITIAL EXAMINATION REPORT REPORT NO.:
50-128/OL-19-01 FACILITY DOCKET NO.:
50-128 FACILITY LICENSE NO.:
R-83 FACILITY:
Triga EXAMINATION DATES:
October 15 - 17, 2018 SUBMITTED BY:
/RA/
12/10/2018 John T. Nguyen, Chief Examiner Date
SUMMARY
During the week of October 15, 2018, the NRC administered an operator licensing examination to six Reactor Operator (RO), one Senior Reactor Operator Instant (SROI) and two Senior Reactor Operator Upgrade (SROU) candidates. One SROU candidate failed the operating test, two RO candidates failed the written examination, and one RO candidate failed both written and operating examinations. All other candidates passed all applicable portions of the examination.
REPORT DETAILS
- 1.
Examiner:
John T. Nguyen, Chief Examiner, NRC
- 2.
Results:
RO PASS/FAIL SRO PASS/FAIL TOTAL PASS/FAIL Written 3/3 1/0 4/3 Operating Tests 5/1 2/1 7/2 Overall 3/3 2/1 5/4
- 3.
Exit Meeting:
John T. Nguyen, Chief Examiner, NRC Jerry Newhouse, Associate Director, Texas A&M University Scott Miller, Reactor Operations Manager, Texas A&M University Cameron MacDonnell, Training Supervisor, Texas A&M University Per discussion with the facility, prior to administration of the examination, adjustments were accepted. The examiner discussed the generic weaknesses observed during the operating test to include questions related to the administrative procedure for replacing facility safety and non-safety significant equipment, the Technical Specifications license amendment, the 10 CFR 50.59 process, and the nuclear instrumentation systems and their calibration procedures. At the conclusion of the meeting, the NRC examiner thanked the facility for their support in the administration of the examination.
ENCLOSURE 2 U.S. NUCLEAR REGULATORY COMMISSION NON-POWER REACTOR LICENSE EXAMINATION FACILITY:
Texas A&M University REACTOR TYPE:
Pool DATE ADMINISTERED:
10/17/2018 CANDIDATE:
INSTRUCTIONS TO CANDIDATE:
Answers are to be written on the Answer sheet provided. Attach all Answer sheets to the examination. Point values are indicated in parentheses for each question. A 70% in each category is required to pass the examination. Examinations will be picked up three (3) hours after the examination starts.
% OF CATEGORY % OF CANDIDATE'S CATEGORY VALUE TOTAL SCORE VALUE CATEGORY 20.00 33.3 A. REACTOR THEORY, THERMODYNAMICS AND FACILITY OPERATING CHARACTERISTICS 20.00 33.3 B. NORMAL AND EMERGENCY OPERATING PROCEDURES AND RADIOLOGICAL CONTROLS 20.00 33.3 C. FACILITY AND RADIATION MONITORING SYSTEMS 60.00 % TOTALS FINAL GRADE All work done on this examination is my own. I have neither given nor received aid.
Candidate's Signature
Category A - Reactor Theory, Thermodynamics, & Facility Operating Characteristics A N S W E R S H E E T Multiple Choice (Circle or X your choice)
If you change your Answer, write your selection in the blank.
A01 a ___ b ___ c ___ d ___ (0.25 each)
A02 a b c d ___
A03 a b c d ___
A04 a b c d ___
A05 a b c d ___
A06 a b c d ___
A07 a b c d ___
A08 a b c d ___
A09 a b c d ___
A10 a b c d ___
A11 a b c d ___
A12 a b c d ___
A13 a b c d ___
A14 a b c d ___
A15 a b c d ___
A16 a b c d ___
A17 a b c d ___
A18 a b c d ___
A19 a b c d ___
A20 a b c d ___
(***** END OF CATEGORY A *****)
Category B - Normal/Emergency Operating Procedures and Radiological Controls A N S W E R S H E E T Multiple Choice (Circle or X your choice)
If you change your Answer, write your selection in the blank.
B01 a b c d ___
B02 a b c d ___
B03 a b c d ___
B04 a b c d ___
B05 a b c d ___
B06 a ___ b ___ c ___ d ___ (0.25 each)
B07 a b c d ___
B08 a b c d ___
B09 a b c d ___
B10 a ___ b ___ c ___ d ___ (0.25 each)
B11 a b c d ___
B12 a b c d ___
B13 a ___ b ___ c ___ d ___ (0.25 each)
B14 a b c d ___
B15 a b c d ___
B16 a b c d ___
B17 a b c d ___
B18 a b c d ___
B19 a b c d ___
B20 a b c d ___
(***** END OF CATEGORY B *****)
C. PLANT AND RAD MONITORING SYSTEMS A N S W E R S H E E T Multiple Choice (Circle or X your choice)
If you change your Answer, write your selection in the blank.
C01 a b c d ___
C02 a b c d ___
C03 a b c d ___
C04 a b c d ___
C05 a ___ b ___ c ___ d ___ (0.5 each)
C06 a b c d ___
C07 a b c d ___
C08 a b c d ___
C09 a ___ b ___ c ___ d ___ (0.5 each)
C10 a b c d ___
C11 a ___ b ___ c ___ d ___ (0.25 each)
C12 a b c d ___
C13 a b c d ___
C14 a b c d ___
C15 a b c d ___
C16 a b c d ___
C17 a ___ b ___ c ___ d ___ (0.25 each)
C18 a b c d ___
(***** END OF CATEGORY C *****)
(********** END OF EXAMINATION **********)
NRC RULES AND GUIDELINES FOR LICENSE EXAMINATIONS During the administration of this examination the following rules apply:
- 1.
Cheating on the examination means an automatic denial of your application and could result in more severe penalties.
- 2.
After the examination has been completed, you must sign the statement on the cover sheet indicating that the work is your own and you have neither received nor given assistance in completing the examination. This must be done after you complete the examination.
- 3.
Restroom trips are to be limited and only one candidate at a time may leave. You must avoid all contacts with anyone outside the examination room to avoid even the appearance or possibility of cheating.
- 4.
Use black ink or dark pencil only to facilitate legible reproductions.
- 5.
Print your name in the blank provided in the upper right-hand corner of the examination cover sheet and each Answer sheet.
- 6.
Mark your Answers on the Answer sheet provided. USE ONLY THE PAPER PROVIDED AND DO NOT WRITE ON THE BACK SIDE OF THE PAGE.
- 7.
The point value for each question is indicated in [brackets] after the question.
- 8.
If the intent of a question is unclear, ask questions of the examiner only.
- 9.
When turning in your examination, assemble the completed examination with examination questions, examination aids and Answer sheets. In addition turn in all scrap paper.
- 10.
Ensure all information you wish to have evaluated as part of your Answer is on your Answer sheet. Scrap paper will be disposed of immediately following the examination.
- 11.
To pass the examination you must achieve a grade of 70 percent or greater in each category.
- 12.
There is a time limit of three (3) hours for completion of the examination.
EQUATION SHEET DR - Rem, Ci - curies, E - Mev, R - feet 1 Curie = 3.7 x 1010 dis/sec 1 kg = 2.21 lb 1 Horsepower = 2.54 x 103 BTU/hr 1 Mw = 3.41 x 106 BTU/hr 1 BTU = 778 ft-lb
°F = 9/5 °C + 32 1 gal (H2O) 8 lb
°C = 5/9 (°F - 32) cP = 1.0 BTU/hr/lb/°F cp = 1 cal/sec/gm/°C
(
)
(
)
2 2
max
=
P 1
sec 1.0
=
eff
=
te P
P 0
eff K
S S
=
1
sec 10 1
4
x
=
+
=
eff SUR 06 26
(
)
(
)
2 1
1 1
2 1
eff eff K
CR K
CR
=
(
)
(
)
2 2
1 1
=
CR CR 2
1 1
1 eff eff K
K M
=
1 2
1 1
CR CR K
M eff
=
=
)
(
0 10 t
SUR P
P=
(
)
0 1
P P
=
eff eff K
K SDM
=1
=
+
+
=
eff 2
1 1
2 eff eff eff eff K
K K
K
=
693
.0 2
1 =
T eff eff K
K 1
=
t e
DR DR
=
0
( )
2 6
R n
E Ci DR=
2 2
2 2
1 1
d DR d
DR
=
(
)
(
)
1 2
1 2
2 2
Peak Peak
=
T UA H
m T
c m
Q P
=
=
=
Category A: Reactor Theory, Thermodynamics, and Facility Operating Characteristics QUESTION A.01
[1.0 point, 0.25 each]
Match the term listed in Column A with its corresponding unit listed in column B.
Column A Column B
- a.
1 barn
- 1. cm -1
- b.
Macroscopic Cross Section
- 2. 10 -24 cm 2
- c.
Neutron Flux
- 3. Neutrons / cm 2 /sec
- d.
Reaction Rate
- 4. Fissions / cm 3 sec QUESTION A.02
[1.0 point]
Which ONE of the following conditions will require the control rod withdrawal to maintain constant power level after the following change?
- a.
Adding of a fuel experiment such as U-235 into the core.
- b.
Removal of an experiment containing borated graphite.
- c.
Increase of pool water temperature.
- d.
Burnout of Xenon in the core.
QUESTION A.03
[1.0 point]
The reactor is critical at 100 watts. A control rod is withdrawn to insert a positive reactivity of 0.126% k/k. Which ONE of the following will be the stable reactor period as a result of this reactivity insertion? Given beta effective = 0.0078
- a.
13 seconds
- b.
46 seconds
- c.
52 seconds
- d.
80 seconds
Category A: Reactor Theory, Thermodynamics, and Facility Operating Characteristics QUESTION A.04
[1.0 point]
For the alpha decay of a nuclide, the number of protons will ___________ and its atomic mass number will __________.
- a.
increase by 2 / increase by 2
- b.
decrease by 2 /decrease by 4
- c.
decrease by 2 / decrease by 2
- d.
increase by 2 / increase by 4 QUESTION A.05
[1.0 point]
Which ONE of the following best describes the likelihood of fission occurring in U-235 and U-238?
- a.
Neutrons at low energy levels (eV) are more likely to cause fission with U-235 than neutrons at higher energy levels (MeV).
- b.
Neutron cross section of U-235 increases with increasing neutron energy, whereas neutron cross section of U-238 decreases with increasing neutron energy.
- c.
Neutrons at low energy levels (eV) are more likely to cause fission with U-238 than neutrons at higher energy levels (MeV).
- d.
Neutron cross sections of U-235 and U-238 are independent from the neutron energy levels.
QUESTION A.06
[1.0 point]
The FAST FISSION FACTOR is defined as a ratio of:
- a.
the number of neutrons that reach thermal energy over the number of fast neutrons that start to slow down.
- b.
the number of fast neutrons produced from fission in a generation over the number of fast neutrons produced from fission in the previous generation.
- c.
the number of fast neutrons produced from U-238 over the number of thermal neutrons produced from U-235.
- d.
the number of fast neutrons produced from all fission over the number of fast neutrons produced from thermal fission.
Category A: Reactor Theory, Thermodynamics, and Facility Operating Characteristics QUESTION A.07
[1.0 point]
Reactor power is 1 watts. Reactor Operator inserts a sample worth of 0.008 k/k into the reactor core. Which ONE of the following best describes the reactor kinetic? The reactor is:
- a.
subcritical
- b.
critical
- c.
supercritical
- d.
prompt critical QUESTION A.08
[1.0 point]
Reactor power is rising on a 10 second period. Approximately how long will it take for power to quadruple?
- a.
14 seconds
- b.
29 seconds
- c.
55 seconds
- d.
72 seconds QUESTION A.09
[1.0 point]
Shown below is a trace of reactor period as a function of time. Between points D and E reactor power is:
- a.
constant.
- b.
continually decreasing.
- c.
continually increasing.
- d.
increasing, then constant.
Category A: Reactor Theory, Thermodynamics, and Facility Operating Characteristics QUESTION A.10
[1.0 point]
Given a source strength of 1000 neutrons per second (N/sec) and a multiplication factor of 0.8, which ONE of the following is the expected stable neutron count rate?
- a.
700 N/sec
- b.
5000 N/sec
- c.
10000 N/sec
- d.
20000 N/sec QUESTION A.11 [1.0 point]
If the multiplication factor, k, is increased from 0.800 to 0.950, the amount of reactivity added is:
- a.
0.150 k/k
- b.
0.197 k/k
- c.
0.250 k/k
- d.
0.297 k/k QUESTION A.12
[1.0 point]
The following data was obtained during a reactor fuel load.
Step No. of Elements Detector A (count/sec) 1 0
100 2
4 120 3
8 140 4
12 200 5
15 400 The estimated number of additional elements required to achieve criticality is between:
- a.
2 to 3
- b.
4 to 5
- c.
6 to 8
- d.
8 to 10
Category A: Reactor Theory, Thermodynamics, and Facility Operating Characteristics QUESTION A.13
[1.0 point]
A reactor is slightly supercritical with the thermal utilization factor = 0.900. A control rod is inserted to bring the reactor back to critical. Assuming all other factors remain unchanged, the new value for the thermal utilization factor is:
- a.
0.898
- b.
0.900
- c.
0.902
- d.
0.904 QUESTION A.14
[1.0 point]
Which ONE of the following isotopes has the largest microscopic absorption cross-section for thermal neutrons?
- a.
Sm149
- b.
U235
- c.
Xe135
- d.
B10 QUESTION A.15
[1.0 point]
Which ONE of the following atoms will cause a neutron to lose the most energy in an elastic collision?
- a.
- b.
Ar-40
- c.
O-16
- d.
H-1
Category A: Reactor Theory, Thermodynamics, and Facility Operating Characteristics QUESTION A.16
[1.0 point]
Which ONE of the following statements correctly describes the concentration of Xenon in the core following a scram from extended operation of 1 Megawatts? Xenon concentration
- a.
initially decreases due to the loss of Iodine production, then increases to maximum concentration.
- b.
eventually decreases to zero in approximately 10 to 15 hours1.736111e-4 days <br />0.00417 hours <br />2.480159e-5 weeks <br />5.7075e-6 months <br /> due to burn out.
- c.
increases to maximum in approximately 7 to 10 hours1.157407e-4 days <br />0.00278 hours <br />1.653439e-5 weeks <br />3.805e-6 months <br /> due to I-135 decay.
- d.
increases to maximum in approximately 7 to 10 hours1.157407e-4 days <br />0.00278 hours <br />1.653439e-5 weeks <br />3.805e-6 months <br /> due to Cs-135 decay.
QUESTION A.17
[1.0 point]
Which ONE of the following is the stable reactor period which will result in a power rise from 10% to 100% power in 10 seconds?
- a.
4 seconds
- b.
10 seconds
- c.
24 seconds
- d.
43 seconds QUESTION A.18
[1.0 point]
A mechanism by which a nucleus can gain stability by converting a neutron to a proton or vice versa is called:
- a.
gamma decay
- b.
beta decay
- c.
alpha decay
- d.
photoelectric effect
Category A: Reactor Theory, Thermodynamics, and Facility Operating Characteristics QUESTION A.19 [1.0 point]
Delayed neutrons are produced by:
- a.
decay of N-16
- b.
Pair Production process
- c.
decay of fission fragments
- d.
directly from the fission QUESTION A.20
[1.0 point]
Reactor is at 100 % power. The following graph shows the reactor time behavior following a reactor scram. Which ONE of the following best describes the transition of power between point B and C after the initial rod insertion?.
- a.
An immediate decrease in the prompt neutron fraction due to leakage, absorption, and a reduction in the fission rate.
- b.
Fission product gases such as xenon begin to buildup causing the expansion of fuel density.
- c.
The longest lived delayed neutron precursor begins to effect such as Bromine-87.
- d.
The short lived delayed neutron precursors begin to effect such as Iodine-137, Cesium-144, and Krypton-95.
Category A: Reactor Theory, Thermodynamics, and Facility Operating Characteristics
(***** END OF CATEGORY A *****)
Category B: Normal/Emergency Operating Procedures and Radiological Controls QUESTION B.01
[1.0 point]
The CURIE content of a radioactive source is a measure of:
- a.
number of radioactive atoms in the source.
- b.
number of nuclear disintegrations per unit time.
- c.
amount of damage to soft body tissue per unit time.
- d.
amount of energy emitted per unit time by the source.
QUESTION B.02
[1.0 point]
How long will it take a 1 Curie source, with a half-life of 1 year, to decay to 0.01 Curie?
- a.
4.6 Years
- b.
6.6 Years
- c.
10.6 Years
- d.
16.6 Years QUESTION B.03
[1.0 point]
An irradiated sample provides a dose rate of 0.5 rem/hr at 2 ft. Approximately how far from the sample reads 5 mrem/hr?
- a.
6 ft.
- b.
9 ft.
- c.
14 ft.
- d.
20 ft.
Category B: Normal/Emergency Operating Procedures and Radiological Controls QUESTION B.04
[1.0 point]
Per SOP, what is a minimum level of authority to approve temporary changes to the operating procedures that do not change the effectiveness or the original intent of the procedures?
- a.
Reactor Safety Board
- b.
NSC Director or his designated alternate
- c.
Reactor Supervisor
- d.
Senior Reactor Operator QUESTION B.05
[1.0 point]
Per NSC Technical Specifications, when Reactor Bridge ARM is inoperable, the reactor operations may continue only if:
- a.
Stack Gas Monitor (FAM Ch.3) is still operable.
- b.
Stack Particulate Monitor (FAM Ch.1) is still operable.
- c.
Stack Particulate Monitor (FAM Ch.1) and Building Particulate Monitor (FAM Ch.4) are still operable.
- d.
Portable gamma sensitive instruments having their own alarm are substituted.
QUESTION B.06
[1.0 point, 0.25 each]
Fill out the blanks with the Limiting Conditions of Operation (LCO) listed in the NSC Technical Specifications.
Safety System LCO
- a.
Core excess reactivity
______ %k/k
- b.
Steady State reactor power
______ KW
- c.
Preset timer
______ sec
- d.
Pool water temperature
______°C
Category B: Normal/Emergency Operating Procedures and Radiological Controls QUESTION B.07
[1.0 point]
You are currently the licensed operator at NSC reactor. Which ONE of the following will violate 10 CFR Part 55.53 Conditions of licenses?
- a.
Last licensed renewal was 60 months ago.
- b.
Last requalification operating test was 18 months ago.
- c.
Last quarter you were the licensed operator for 5 hours5.787037e-5 days <br />0.00139 hours <br />8.267196e-6 weeks <br />1.9025e-6 months <br />.
- d.
Last requalification written examination was 18 months ago.
QUESTION B.08
[1.0 point]
The radioactive solid waste is surveyed with the NaI (Tl) detector. The reading is between 20 %
- 25 % above background. How do you deal with this radioactive waste?
- a.
Considering it is a non-radioactive waste.
- b.
Reporting it is an emergency event, Notification of Unusual Event.
- c.
Classifing the entire room is a radiation area in accordance with 10 CFR 20.
- d.
Considering it is a radioactive waste and placed into a radioactive bag.
QUESTION B.09
[1.0 point]
The dose rate from a mixed beta-gamma point source is 100 mrem/hour at a distance of one (1) foot, and is 0.1 mrem/hour at a distance of ten (10) feet. What percentage of the source consists of beta radiation?
- a.
30%
- b.
50%
- c.
70%
- d.
90%
Category B: Normal/Emergency Operating Procedures and Radiological Controls QUESTION B.10
[1.0 point, 0.25 each]
Identify each of the following surveillances as a channel check (CHECK), a channel test (TEST), or a channel calibration (CAL).
- a.
During the startup, you verify a reactor high power scram.
- b.
During the startup, you verify the reactor interlock system by performing simultaneous manual withdrawal of two control blades.
- c.
During reactor operation, you compare reading of radiation monitors.
- d.
Adjust the scram set point of the Reactor Bridge ARM with recent data collected on the calibration.
QUESTION B.11
[1.0 point]
Which ONE of the following statements correctly describes the relationship between the Safety Limit (SL) and the Limiting Safety System Setting (LSSS)?
- a.
The SL is a maximum operationally limiting value that prevents exceeding the LSSS during normal operations.
- b.
The SL is a parameter that assures the integrity of the fuel cladding. The LSSS initiates protective actions to preclude reaching the SL.
- c.
The SL is a maximum setpoint for instrumentation response. The LSSS is the minimum number of channels required to be operable.
- d.
The LSSS is a parameter that assures the integrity of the fuel cladding. The SL initiates protective action to preclude reaching the LSSS.
QUESTION B.12
[1.0 point]
In accordance with 10CFR20.1301, individual members of the public are limited to a TEDE in one year of:
- a.
50 mrem.
- b.
100 mrem.
- c.
500 mrem.
- d.
1250 mrem.
Category B: Normal/Emergency Operating Procedures and Radiological Controls QUESTION B.13
[1.0 point, 0.25 each]
Identify each of the following as either a Safety Limit (SL) a Limiting Safety System Setting (LSSS) or a Limiting Condition for Operation (LCO).
- a.
The temperature in a stainless steel-clad TRIGA LEU fuel element shall not exceed 1150°C under any conditions of operation.
- b.
The reactor power level shall not exceed 1.0 megawatt (MW) during steady state operation.
- c.
The fuel temperature shall not exceed 525°C as measured in an instrumented fuel element (IFE).
- d.
The central exhaust system shall be considered operating when it creates a minimum of 0.1 inch of water negative pressure at the sample point in the central exhaust system duct work.
QUESTION B.14
[1.0 point]
In order to ensure the health and safety of the public, 10CFR50 allows the operator to deviate from Technical Specifications. What is the minimum level of authorization needed to deviate from Technical Specifications?
- a.
Director of Reactor Operations
- b.
NSCSC
- c.
Licensed Senior Reactor Operator.
- d.
Licensed Reactor Operator.
QUESTION B.15
[1.0 point]
Which ONE of the following experiments is not allowed to be installed in the reactor or experiment facilities under ANY condition? The experiment:
- a.
contains corrosive materials.
- b.
contains 15 milligrams of TNT material.
- c.
has an secured experiment worth of $1.9.
- d.
has a single, movable experiment worth of $1.0.
Category B: Normal/Emergency Operating Procedures and Radiological Controls QUESTION B.16
[1.0 point]
A two-curie source, emitted 80% of 100 Kev gamma, is to be stored in the reactor building.
How far from the source will it read 100 mrem/hr?
- a.
3 feet
- b.
10 feet
- c.
13 feet
- d.
100 feet QUESTION B.17
[1.0 point]
All applicants for an RO or SRO license must submit NRC Form 396 and 398 to the U.S. NRC before taking the examinations. This requirement is specified in 10 CFR:
- a.
Part 19
- b.
Part 20
- c.
Part 50
- d.
Part 55 QUESTION B.18
[1.0 point]
According to emergency classification guide, the pool leakage which indicated abnormal loss at a rate exceeding makeup capacity is defined as:
- a.
Operational Event
- b.
Notification of Unusual Event
- c.
Alert
- d.
Site Area Emergency
Category B: Normal/Emergency Operating Procedures and Radiological Controls QUESTION B.19
[1.0 point]
Per NSC Technical Specifications, the primary coolant temperature channel shall be calibrated:
- a.
monthly.
- b.
quarterly.
- c.
semiannually.
- d.
annually.
QUESTION B.20
[1.0 point]
To measure the scram time measurement (Oscilloscope Method) for the SHIM rod, the SHIM rod should be withdrawn to _____before pressing the fuel temperature scram test button.
- a.
25%
- b.
50%
- c.
75%
- d.
100%
(***** END OF CATEGORY B *****)
Category C: Facility and Radiation Monitoring Systems QUESTION C.01
[1.0 point]
The following diagram depicts the control rod armature. Which ONE of the following numbers listed on the diagram correctly describes the Dashpot Port?
- a.
1
- b.
4
- c.
6
- d.
8
Category C: Facility and Radiation Monitoring Systems QUESTION C.02
[1.0 point]
The Facility Air Monitor (FAM) air flow configuration is color coded in accordance with the location where its air sample is coming from. If the air sample is coming from the reactor bridge, the color code is:
- a.
Blue
- b.
Red
- c.
Green
- d.
Yellow QUESTION C.03
[1.0 point]
If a presence of ____ is found in the secondary side of the heat exchanger, a possible leak occurs from the primary system to the secondary system.
- a.
Na-24
- b.
Neutrons
- c.
Ar-41
- d.
N-16 QUESTION C.04
[1.0 point]
Which ONE of the following is the main purpose of the thermal column?
- a.
To enhance natural convection flow.
- b.
Provide a thermal neutron flux for a film irradiation facility.
- c.
Provide a fast (high energy) neutron flux for a film irradiation facility.
- d.
To shield a radiation dose from reactor core to the experiment area.
Category C: Facility and Radiation Monitoring Systems QUESTION C.05
[2.0 points, 0.5 each]
Identify whether each of the following Reactor Safety Channels shall be effective in the Steady State (SS) mode, the Pulse mode (PULSE), or both modes (BOTH)
- a.
Console Scram Button
- b.
High Power Level
- c.
Preset Timer
- d.
Fuel Element Temperature QUESTION C.06
[1.0 point]
The main purpose of the fuel followers installed in the control rods is to:
- a.
decrease the fast neutron flux in the core.
- b.
enhance their control characteristics.
- c.
increase the core excess reactivity in the reactor core.
- d.
increase the effectiveness for reactor pulsing.
QUESTION C.07
[1.0 point]
Reactor power is 1 KW. If you accidently press the Period Scram Bypass button, the reactor will:
- a.
- b.
prevent rod withdrawal.
- c.
run down.
- d.
be in normal (nothing happen).
Category C: Facility and Radiation Monitoring Systems QUESTION C.08
[1.0 point]
The Safety control rod is partially withdrawn from the core. At this point, the Log Power level, for some unknown reason, drops to 1.0
- 10 -3 W. As a result:
- a.
the control rod cannot be withdrawn any further.
- b.
the control rod cannot be inserted any further.
- c.
the control rod stuck and cannot be moved in any direction.
- d.
the control rod can only be inserted by placing the key switch in the OFF position.
QUESTION C.09
[2.0 points, 0.5 each]
Match the item provided in column A, with the correct Nuclear Instrumentation Channel from column B. (Items in column B may be used once, more than once, or not at all.)
Column A Column B
- a.
< 1 cps rod withdrawal inhibit
- 1.
Safety Power Channel
- b.
1 KW Interlock
- 2.
Log Power Channel
- c.
Scram at 125% of full power
- 3.
Wide Range Linear Channel
- d.
Energy (MW-Sec)
- 4.
Reactor Pool Temperature
- 5.
Pulse Channel
Category C: Facility and Radiation Monitoring Systems QUESTION C.10
[1.0 point]
A three-way solenoid valve controls the air supplied to the pneumatic cylinder of the Transient rod. De-energizing the solenoid causes the valve to shift to:
- a.
open, admitting air to the cylinder.
- b.
close, admitting air to the cylinder.
- c.
open, removing air from the cylinder.
- d.
close, removing air from the cylinder.
QUESTION C.11
[1.0 point, 0.25 each]
Match the input signals listed in column A with their display on reactor control room listed in column B. (Items in column B may be used more than once or not at all). Assume that the reactor is in operation.
Column A Column B
- a.
Cell door open (in stall)
- 1.
Alarm only
- b.
Servo Fault
- 2.
Rod withdraw prohibit
- c.
125% Safety Power Channel
- 3.
Alarm and scram
- d.
Withdrawal of safety rod
- 4.
Alarm and rod run-in if its rod height is fully out QUESTION C.12
[1.0 point]
The Figure below depicts:
- a.
The Compensated Ion Chamber.
- b.
The Uncompensated Ion Chamber.
- c.
The Gamma Ion Chamber.
- d.
The Fission Chamber.
Category C: Facility and Radiation Monitoring Systems
Category C: Facility and Radiation Monitoring Systems QUESTION C.13
[1.0 point]
Which ONE of the following is NOT true regarding the configuration of TAMU TRIGA-LEU fuel elements?
- a.
Uranium content: Maximum of 30 wt% enriched to maximum 19.95% Uranium-235 with nominal enrichment of 19.75% Uranium-235.
- b.
Hydrogen-to-zirconium atom ratio (in the ZrHx): nominal 1.0 H atoms to 1.6 Zr atoms with a maximum H to Zr ratio of 1.05.
- c.
Natural erbium content (homogeneously distributed): nominal 0.90 wt%.
- d.
Cladding: 304 stainless steel.
QUESTION C.14
[1.0 point]
Reactor is subcritical with the following conditions:
The SHIM rods and drives are DOWN The Carriage of the Transient rod is UP Reactor is in the Steady State Mode If you apply AIR to the Transient rod system, the reactor will:
- a.
- b.
inhibit (interlock).
- c.
change to Pulse Mode.
- d.
increase to critical.
QUESTION C.15
[1.0 point]
Reactor power is 10 W. A reactor staff accidentally open the door of the Beam Port 4 Cave.
His action will cause:
- a.
an annunciator light in the control room.
- b.
normal operation, no indication.
- c.
a reactor scram.
- d.
a reactor interlock.
Category C: Facility and Radiation Monitoring Systems QUESTION C.16
[1.0 point]
When the pool level falls to approximately 90% of normal operating level, it will initiate visual and audible alarms in certain locations. Which ONE of the following locations gets an indication of visual and audible alarms?
- a.
Reception Room
- b.
University Communications Room
- c.
Director Office
- d.
Reactor Bay QUESTION C.17
[1.0 point, 0.25 each]
The following diagram depicts the FUEL FOLLOWED control rod. Match each distractor with an appropriate label listed in the diagram.
- a.
Fuel
- b.
Stainless steel plug
- c.
Void
- d.
Borated Graphite
Category C: Facility and Radiation Monitoring Systems
Category C: Facility and Radiation Monitoring Systems QUESTION C.18
[1.0 point]
If any significant buildup of radioactivity from the reactor pool, the conductivity of the pool water will be:
- a.
increase.
- b.
decrease.
- c.
the same.
- d.
no relationship between radioactivity and conductivity in the pool water.
(***** END OF CATEGORY C *****)
((***** END OF EXAM *****))
Category A: Reactor Theory, Thermodynamics, and Facility Operating Characteristics A.01 Answer:
a(2) b(1) c(3) d(4)
(0.25 each)
Reference:
Burn, R., Introduction to Nuclear Reactor Operations, © 1988, Sec 2.6 A.02 Answer:
c
Reference:
Burn, R., Introduction of Nuclear Reactor Operations, © 1988, Sec 3.3.1 A.03 Answer:
c
Reference:
Reactivity added = 0.126 % k/k = 0.00126 k/k
= (-)/eff = 0.0078 - 0.00126 = 51.9 seconds (0.1) (0.00126)
A.04 Answer:
b
Reference:
Chart of the Nuclides A.05 Answer:
a
Reference:
Burn, R., Introduction to Nuclear Reactor Operations, © 1988, Section 3.2 A.06 Answer:
d
Reference:
Burn, R., Introduction of Nuclear Reactor Operations, © 1982, Sec 3.3.1, page 3-16.
A.07 Answer:
d
Reference:
Burn, R., Introduction of Nuclear Reactor Operations, © 1988, Sec 4.2 When the insertion of 0.008 k/k > Keff, reactor is prompt critical.
A.08 Answer:
a
Reference:
P = P0 et/T --> ln(4) = time ÷ 10 seconds -> time = ln (4) x 10 sec. 1.386 x 10 13.8 sec.
A.09 Answer:
d
Reference:
Reactor is increasing, then constant when reactor period reaches to infinitive.
A.10 Answer:
b
Reference:
CR = S/(1-K) CR = 1000/(1 - 0.8) = 5000 N/sec A.11 Answer:
b
Reference:
Burn, R., Introduction to Nuclear Reactor Operations, © 1982, Sec 3.3.3, page 3-
- 21.
= keff1-keff2/(keff1 x keff2) = 0.95-0.8 /(0.8*0.95)=0.197 k/k
Category A: Reactor Theory, Thermodynamics, and Facility Operating Characteristics A.12 Answer:
a
Reference:
Burn, R., Introduction to Nuclear Reactor Operations, © 1982, Sec 5.5, page 5-18-5-25.
A.13 Answer:
a
Reference:
Burn, R., Introduction of Nuclear Reactor Operations, © 1988, Sec 3.3.1 A.14 Answer c
Reference:
Introduction to Nuclear Operation, Reed Burn, 1988, Sec 8.1 A.15 Answer:
d
Reference:
Burn, R., Introduction of Nuclear Reactor Operations, © 1988, Sec 2.5.3 A.16 Answer:
c
Reference:
Burn, R., Introduction of Nuclear Reactor Operations, © 1988, Sec 8.2 A.17 Answer:
a
Reference:
P = P0 e t/T --> T= t/Ln(P/ P0 )
T= 10/Ln(100/10 ); T = 4.34 sec.
A.18 Answer:
b
Reference:
NRC Standard Question A.19 Answer:
c
Reference:
Burn, R., Introduction of Nuclear Reactor Operations, © 1982, Sec 3.2.1 A.20 Answer:
d
Reference:
Burn, R., Introduction to Nuclear Reactor Operations, ©4.5, 1988
Category B: Normal/Emergency Operating Procedures and Radiological Controls B.01 Answer:
b
Reference:
Standard Health Physics Definition B.02 Answer:
b
Reference:
A = A*e -t 0.01Ci = 1 Ci* e -(t)
= ln(2) / (half-life)
= 0.693 / 1 year = 0.693 ln(0.01/1) = -0.693*(t) --> -4.60/-0.693 solve for t: 6.6 years B.03 Answer:
d
Reference:
DR1*(D1 ) 2= DR2*(D2) 2 ;
500 mrem (2) 2 = 5 mrem (d) 2 D = 20 ft B.04 Answer:
b
Reference:
SOP, Procedure F,Section I B.05 Answer:
d
Reference:
TS 5.1 B.06 Answer:
- a. = 5.5;
- b. = 1000;
- c. = 15;
- d. = 60 (0.25 each)
Reference:
TS 3.1.1, TS 3.1.5, TS 3.2.2 B.07 Answer:
b
Reference:
- 55.53(i) - the licensee shall have a biennial medical examination.
- 55.53(h), 55.59(c) - annual operating tests
- 55.53(e) - the licensee shall actively perform the functions of a licensed operator for a minimum of 4 hours4.62963e-5 days <br />0.00111 hours <br />6.613757e-6 weeks <br />1.522e-6 months <br /> per calendar quarter.
- 55.53(h), 55.59(c)(1) - The requalification program must be conducted for a continuous period not to exceed 2 years License renewal : 6 years B.08 Answer:
d
Reference:
SOP, Procedure C7,Section VII
Category B: Normal/Emergency Operating Procedures and Radiological Controls B.09 Answer:
d
Reference:
10CFR20 - At 10 feet, there is no beta radiation.
Calculate gamma at 1 ft.
DR1*(D1 ) 2= DR2*(D2) 2 0.1*(10 ) 2= DR2*(1) 2 gamma at 1 foot = 10 mrem/hour.
Therefore, beta at 1 foot = 90 mrem/hour or 90%.
B.10 Answer:
- a. = TEST;
- b. = TEST;
- c. = CHECK; d. = CAL (0.25 each)
Reference:
TS Definitions B.11 Answer:
b
Reference:
TS 2.1.2 and 2.2.1, Objective B.12 Answer:
b
Reference:
10CFR20 B.13 Answer:
- a. = SL;
- b. = LCO;
- c. = LSSS;
- d. = LCO (0.25 each)
Reference:
TS 2.1, TS 2.2, TS 3.1, TS 3.2, and TS 3.3 B.14 Answer:
c
Reference:
B.15 Answer:
d
Reference:
TS 3.6 B.16 Answer:
a
Reference:
6CEN = R/hr @ 1 ft. -> 6 x 2 x 0.8 x 0.1 = 0.96 R/hr at 1ft.
I0D02 = I*D2 0.96 R/hr*(1 ft) 2 = 0.1 R/hr *D 2 D= sqrt(0.96/0.1) = 3 ft.
B.17 Answer:
d
Reference:
10CFR55 B.18 Answer:
c
Reference:
Emergency Plan, Section 4, Emergency Classification System Table-I.
Category B: Normal/Emergency Operating Procedures and Radiological Controls B.19 Answer:
c
Reference:
TS 4.8.3 B.20 Answer:
d
Reference:
SOP, Procedure I,Section III
Category C: Facility and Radiation Monitoring Systems C.01 Answer:
d
Reference:
SAR 7.3.1 C.02 Answer:
b
Reference:
SOP, Procedure VII-F1,Section VII C.03 Answer:
a
Reference:
NRC Standard Questions C.04 Answer:
b
Reference:
SAR 10.1.2 C.05 Answer:
- a. = BOTH;
- b. = SS;
- c. = PULSE;
- d. = BOTH (0.5 each)
Reference:
TS 3.2 C.06 Answer:
c
Reference:
SAR 1.8 C.07 Answer:
d
Reference:
SOP, Procedure D,Section II C.08 Answer:
a
Reference:
TS 3.2 C.09 Answer:
a,2 b,2 c,1 d,5 (0.5 each)
Reference:
SAR 7.2.3 C.10 Answer:
d
Reference:
TS 7.3.1 C.11 Answer:
a(1) b(1) c(3) d(2)
(0.25 each)
Reference:
TS 3.3 and SAR 7.0, Instrumentation and Control C.12 Answer:
a
Reference:
NRC Standard Questions
Category C: Facility and Radiation Monitoring Systems C.13 Answer:
b
Reference:
TS 5.2 C.14 Answer:
b
Reference:
TS 3.2.2 C.15 Answer:
c
Reference:
SOP, Procedure D,Section IV C.16 Answer:
b
Reference:
SOP, Procedure O,Section III, Reactor Pool Surveillance C.17 Answer:
a (IV) b (II) c (I) d (III)
(0.25 each)
Reference:
SAR 4.2.2 C.18 Answer:
a
Reference:
NRC Standard Questions