IR 05000128/2010201

From kanterella
Jump to navigation Jump to search
IR 05000128-10-201 on 11/15/10 - 11/18/2010, Texas Engineering Experiment Station (Texas a & M University), NRC Routine Inspection Report
ML103430006
Person / Time
Site: 05000128
Issue date: 12/16/2010
From: Johnny Eads
Research and Test Reactors Branch B
To: Hall K
Texas A&M Univ
Morlang, G M, NRR/DPR, 415-4092
References
IR-10-201
Download: ML103430006 (20)


Text

ber 16, 2010

SUBJECT:

TEXAS ENGINEERING EXPERIMENT STATION, NRC ROUTINE INSPECTION REPORT NO. 50-128/2010-201

Dear Dr. Hall:

On November 15-18, 2010, the U. S. Nuclear Regulatory Commission (NRC, the Commission)

conducted an inspection at your Nuclear Science Center TRIGA Research Reactor Facility.

The enclosed report documents the inspection results, which were discussed on November 18, 2010, with Dr. W. D. Reece, Director of the Nuclear Science Center, and other members of your staff.

The inspection examined activities conducted under your license as they relate to safety and compliance with the Commission=s rules and regulations and with the conditions of your license.

The inspectors reviewed selected procedures and records, observed activities, and interviewed personnel. Based on the results of this inspection, no findings of significance were identified.

In accordance with Title 10 of the Code of Federal Regulations Section 2.390 Public inspections, exemptions and requests for withholding a copy of this letter, its enclosure, and your response (if any) will be made available electronically for public inspection in the NRC Public Document Room or from the Publicly Available Records (PARS) component of NRCs document system (Agencywide Documents Access and Management System (ADAMS)).

Adams is accessible from the NRC Web site at http://www.nrc.gov/reading-rm/adams.html (the Public Electronic Reading Room).

Should you have any questions concerning this inspection, please contact Mr. Gary Morlang at (301) 415-4092 or by electronic mail at Gary.Morlang@nrc.gov.

Sincerely,

/MVoth for RA/

Johnny H. Eads Jr., Chief Research and Test Reactors Oversight Branch Division of Policy and Rulemaking Office of Nuclear Reactor Regulation Docket No. 50-128 License No. R-83 Enclosure: NRC Inspection Report No. 50-128/2010-201 cc w/encl: Please see next page

Texas A&M University System Docket No. 50-128 cc:

Mayor, City of College Station Susan M. Jablonski P.O. Box Drawer 9960 Technical Advisor College Station, TX 77840-3575 Office of Permitting, Remediation &

Registration Governors Budget and Texas Commission on Environmental Planning Office Quality P.O. Box 13561 P.O. Box 13087, MS 122 Austin, TX 78711 Austin, TX 78711-3087 Texas A&M University System Roger Mulder ATTN: Dr. Warren D. Reece, Director State Energy Conservation Office Nuclear Science Center Comptroller of Public Accounts Texas Engineering Experiment Station P.O. Box 13528 1095 Nuclear Science Road, M/S 3575 Austin, TX 78711-3528 College Station, Texas 77843 Test, Research and Training Texas A&M University System Reactor Newsletter ATTN: Jim Remlinger, Associate Director 202 Nuclear Sciences Building Nuclear Science Center University of Florida ber 16, 2010

SUBJECT:

TEXAS ENGINEERING EXPERIMENT STATION, NRC ROUTINE INSPECTION REPORT NO. 50-128/2010-201

Dear D