MONTHYEARML0606806112006-03-19019 March 2006 Ohio State University, Request for Additional Information, License Renewal, Ohio State University Research Reactor Project stage: RAI ML0607601092006-03-31031 March 2006 Request for Additional Information Regarding Ohio State University Research Reactor Environmental Report for License R-75 Renewal Project stage: RAI ML0611101432006-04-13013 April 2006 Request for Additional Information Regarding License Renewal, for the Ohio State University Research Reactor Project stage: Request ML0611101462006-04-14014 April 2006 Request for Additional Information Regarding Ohio State University Research Reactor Environmental Report for License R-75 Renewal Project stage: Request ML0611706172006-05-0202 May 2006 Letter to Mr. Andrew Kauffman from Daniel E. Hughes Request for Oath and Affirmation for Relicensing Application of Ohio State University Research Reactor License R-75 Project stage: Other ML0615001222006-05-19019 May 2006 NRC Request for Oath and Affirmation for Relicensing Application of Ohio State University Research Reactor Project stage: Request ML0526601612006-06-0505 June 2006 Determination of Acceptability and Sufficiency for Docketing and Opportunity for a Hearing Regarding the Application from the Ohio State University (Osu) for Renewal of the Facility License for the Ohio State University Research Reactor Project stage: Other ML0620900722006-07-26026 July 2006 Responses Provided to the Request for Additional Information Regarding Ohio State University Research Reactor Environmental Report for License R-75 Renewal Project stage: Request ML0620807122006-07-26026 July 2006 Response to the Request for Additional Information Regarding License Renewal, Ohio State University Project stage: Request ML0707905192007-03-29029 March 2007 Request for Assurance of Decommissioning Funding for License Renewal for the Ohio State University Research Reactor Project stage: Other ML0711600502007-04-24024 April 2007 Ohio State University - Acknowledgement of Letter Received Request for Assurance of Decommissioning Funding for License Renewal Project stage: Request ML0712100022007-05-0404 May 2007 Request for Additional Information Regarding Financial Qualification for License Renewal for the Ohio State University (Osu) Research Reactor Project stage: RAI ML0714304172007-05-14014 May 2007 Assurance of Decommissioning Funding for the Ohio State University Research Reactor (OSURR) License Renewal Project stage: Other ML0714304162007-05-22022 May 2007 Response to NRC Request for Assurance of Decommissioning Funding for License Renewal for the Ohio State University Research Reactor Project stage: Request ML0715500982007-05-31031 May 2007 Response to NRC Request for Additional Information Regarding Financial Qualification for License Renewal for the Ohio State University (Osu) Research Reactor Project stage: Response to RAI ML0718602692007-07-0505 July 2007 Request for Additional Information Regarding the Ohio State University Research Reactor Application for Re-Licensing Project stage: RAI ML0721400092007-07-30030 July 2007 Request for Additional Information Regarding the Ohio State University Research Reactor (OSURR) Application for Re-licensing Project stage: Request ML0723304952007-08-21021 August 2007 Request for Additional Information Regarding the Ohio State University Research Reactor Application for Re-Licensing Project stage: RAI ML0726201772007-09-17017 September 2007 Letter Request for Additional Information Regarding the Ohio State University Research Reactor (OSURR) Application for Re-licensing Project stage: Request ML0727500382007-09-28028 September 2007 Response to Request for Additional Information Regarding the Ohio State University Research Reactor Application for Re-licensing Project stage: Response to RAI ML0730400192007-10-31031 October 2007 Request for Additional Information Regarding the Ohio State University Research Reactor Application for Re-Licensing Project stage: RAI ML0806503522008-02-29029 February 2008 Response to Request for Additional Information Regarding the Ohio State University Research Reactor (OSURR) Application for Re-Licensing Project stage: Response to RAI ML0702300042008-04-0707 April 2008 Ohio State University Research Reactor Environmental Assessment Regarding Amendment for Renewal of Facility License No. R-75 Project stage: Other ML0810006182008-06-18018 June 2008 Issuance of Renewed Facility License No. R-75 for the Ohio State University Research Reactor Project stage: Approval 2007-05-14
[Table View] |
|
---|
Category:Letter
MONTHYEARML24012A0282024-01-0808 January 2024 Administrative Change at the Ohio State University Research Reactor (OSURR) ML24002A7372024-01-0303 January 2024 Ohio State University - Change of Facility Project Manager ML23258A0892023-09-11011 September 2023 Ohio State University, Annual Report for Fy 2022/2023 IR 05000150/20232012023-03-16016 March 2023 Ohio State University - U.S. Nuclear Regulatory Commission Safety Inspection Report No. 05000150/2023201 IR 05000150/20232022023-03-13013 March 2023 Ohio State University - U.S. Nuclear Regulatory Commission Security Inspection Report No. 05000150/2023202 (Public) ML22257A1052022-09-0909 September 2022 Annual Report for the Ohio State University Research Reactor ML22070B0942022-04-12012 April 2022 Ohio State University U.S. Nuclear Regulatory Commission Safety Inspection Report ML22060A1042022-02-24024 February 2022 Report Regarding Loss of Building Exhaust Fan on February 14, 2022, While Operating the Ohio State University Research Reactor ML21267A3982021-09-13013 September 2021 Annual Report for the Ohio State University Research Reactor ML21215A0802021-08-11011 August 2021 Examination Confirmation Letter No. 50-150/OL-21-01, Ohio State University IR 05000150/20202012021-03-30030 March 2021 Ohio State University Routine Inspection Report 05000150/2020201 ML20295A4242020-11-16016 November 2020 Notification of Mailing Address Change Regarding Submittal of Fingerprint Cards ML20262H0622020-09-0909 September 2020 Annual Report for the Ohio State University Research Reactor, License R-75, Docket 50-150 ML19317D7992019-11-0606 November 2019 Replacement Pages for Modified Technical Specification 3.5 of Renewed Facility Operating License No. R-75 of the Ohio State University Research Reactor ML19298A1102019-10-22022 October 2019 Ohio State University - Revision to the Request for Modification of Technical Specifications 3.5 and 5.1.2 of Renewed Facility Operating License No. 75 ML19266A0282019-09-16016 September 2019 Annual Report for the Ohio State University Research Reactor ML19253A0512019-09-0606 September 2019 Additional Information to Support the Request for Modification of Technical Specifications 3.5 and 5.1.2 of Renewed Facility Operating License No. R-75 of the Ohio State University Research Reactor ML19105A1372019-04-10010 April 2019 Response to NRC Request for Additional Information (RAI) Letter to the Ohio State University Research Reactor (OSURR, License R-75) Dated January 16, 2019 ML19063A4992019-02-27027 February 2019 Response to NRC RAI Letter Dated 16-January-2019 Regarding License Amendment Request to Modify Technical Specifications 3.5 and 5.1.2 for License R-75 of the Ohio State University Research Reactor ML18360A3592019-01-16016 January 2019 the Ohio State University - Request for Additional Information License Amendment Request to Modify Technical Specifications 3.5 and 5.1.2 of Renewed Facility Operating License No. R-75 of the Ohio State University Research IR 05000150/20182012019-01-0909 January 2019 Ohio State University - U.S. Nuclear Regulatory Commission Safety Inspection Report 05000150/2018201 ML18324A5852018-11-14014 November 2018 Relevant Sections of the Ohio State University Research Reactor (OSURR, License R-75, Docket 50-150) Safety Analysis Report (SAR) to Support a Technical Specifications Amendment Request ML18303A1892018-10-31031 October 2018 the Ohio State University - Acceptance of Requested Licensing Action License Amendment Request to Modify Technical Specifications 3.5 and 5.1.2 of Renewed Facility Operating License No. R75 ML18291A9132018-10-16016 October 2018 Additional Information to Support a Technical Specifications Amendment Request for the Ohio State University Research Reactor (OSURR, License R-75, Docket 50-150) ML18270A1662018-10-0303 October 2018 the Ohio State University Nuclear Reactor Laboratory, Non-Acceptance of Amendment Request with Opportunity to Supplement, for the Renewed Facility License No. R-75 (CAC No. A11010/05000150) ML18267A0602018-09-18018 September 2018 the Ohio State University, Submittal of Annual Report for Fy 2017/2018 ML18242A0752018-08-27027 August 2018 Request for an Amendment to the Ohio State University Research Reactor IR 05000150/20172012018-02-13013 February 2018 Ohio State University - Nuclear Regulatory Commission Safety Inspection Report No. 50-150/2017-201 ML17285A4802017-10-18018 October 2017 the Ohio State University Nuclear Reactor Laboratory, Non-Acceptance of Amendment Request with Opportunity to Supplement, for the Renewed Facility License No. R-75 ML17244A2322017-08-22022 August 2017 Request for an Amendment to the Ohio State University Research Reactor Technical Specifications ML17118A3222017-05-0404 May 2017 Non-Power Reactor Closeout of Generic Letter 2016-01, Monitoring of Neutron Absorbing Materials in Spent Fuel Pools for the Ohio State University Research Reactor Docket No. 50-150 ML17088A1272017-03-23023 March 2017 the Ohio State University - Response to Generic Letter 2016-01 ML17086A0282017-03-22022 March 2017 Ohio State University Research Reactor - Updated Emergency Plan ML17081A4422017-03-20020 March 2017 Ohio State University, Response to Generic Letter 2016-01 IR 05000150/20162022016-10-20020 October 2016 Ohio State University - Nuclear Regulatory Commission Security Inspection Report No. 50-150/2016-202 (Letter Only) ML16273A0082016-09-30030 September 2016 Ohio State University - NRC Safety Inspection Report 05000150/2016201 ML16210A4042016-07-21021 July 2016 Ohio State University, Administrative Change Update ML16200A3542016-07-13013 July 2016 the Ohio State University - Submittal of Updated Emergency Plan for the Ohio State University Research Reactor (Osurr), License R-75, Docket 50-150 ML16084A0012016-04-0101 April 2016 CAL closure letter for Ohio State ML16060A1032016-02-23023 February 2016 Request to Closeout the Compensatory Measures for the Ohio State University Research Reactor IR 05000150/20152012015-12-0404 December 2015 IR 05000150/2015201, November 2-5, 2015, Ohio State University ML15265A5212015-09-18018 September 2015 Ohio State University - Annual Report for Fy 2014/2015 ML14290A4862015-06-0303 June 2015 Y020140127 - Withdrawal of Order EA-05-007, Order Imposing Additional Security Measures IR 05000000/20001502014-11-0606 November 2014 IR 05000000-150-2014-201 on October 6-9, 2014, Ohio State University, NRC Routine Inspection Report ML14272A0942014-09-24024 September 2014 Ohio State University Research Reactor,Submittal of Annual Report for Fy 2013/2014 ML14133A7222014-05-27027 May 2014 Ohio State University - Change of Facility Project Managers ML13269A0762013-09-23023 September 2013 Ohio State University Research Reactor, Annual Report ML13226A0702013-08-12012 August 2013 Rescission of Certain Security Orders Concerning Spent Nuclear Fuel in Transit ML12286A0442012-10-16016 October 2012 Examination Report No. 50-150/OL-12-01, the Ohio State University ML12286A0422012-10-16016 October 2012 Examination Results Letter, No. 50-150/OL-12-01, the Ohio State University 2024-01-08
[Table view] |
Text
March 29, 2007Mr. Andrew KauffmanThe Ohio State University Nuclear Reactor Laboratory 1298 Kinnear Road Columbus, OH 43212-1154
SUBJECT:
REQUEST FOR ASSURANCE OF DECOMMISSIONING FUNDING FORLICENSE RENEWAL FOR THE OHIO STATE UNIVERSITY (OSU) RESEARCH REACTOR (TAC NO. MA7724)
Dear Mr. Kauffman:
By letter dated July 26, 2006, OSU supplemented its license renewal application for theResearch Reactor to include financial information pertaining to operation and decommissioning of the reactor. This letter does not satisfy the requirements for assurance of decommissioning funding for license renewal. The position of the NRC is that OSU has assurance from the State of Ohio for decommissioning funding under the current license, but updated assurance of decommissioning funding is required for license renewal. Title 10 of the Code of Federal Regulations, Part 50.75(e)(iv) permits State licensees toprovide assurance of decommissioning funding by "a statement of intent containing a cost estimate for decommissioning, and indicating that funds for decommissioning will be obtained when necessary." The statement of intent must be signed by an official who has the authority to commit to spending the necessary funds to accomplish decommissioning, and it should be clearly asserted in the statement of intent that the signing official has that authority. In addition, the statement of intent should contain a statement that funding will be provided sufficiently in advance of decommissioning to prevent delay of required activities. If decommissioning funding is to continue to be assured by the State of Ohio, submit an updated statement of intent to this effect, signed by an appropriate State official. Otherwise, 10 CFR 50.75(e) provides alternate options for assurance of decommissioning funding.Please provide the necessary documentation within 30 days of the date of this letter. Inaccordance with 10 CFR 50.30(b), your response and the statement of intent must be executed in a signed original under oath or affirmation. If you have any questions, please contact William B. Kennedy at 301- 415-2784, or me at 301- 415-1631.Sincerely,/RA/Daniel E. Hughes, Project ManagerResearch and Test Reactors Branch A Division of Policy and Rulemaking Office of Nuclear Reactor RegulationDocket No. 50-150cc: See next page Ohio State UniversityDocket No. 50-150 cc:
Robert Owen, Chief Bureau of Radiation Protection Ohio Department of Health 246 North High Street Columbus, OH 43215Carol O'ClaireRadiological Branch Chief Ohio Emergency Management Agency 2855 West Dublin-Granville Road Columbus, OH 43235-2206Kevin Herminghuysen Research Associate Nuclear Reactor Laboratory The Ohio State University 1298 Kinnear Road Columbus, OH 43212Richard Denning, Director Nuclear Reactor Laboratory The Ohio State University 1298 Kinnear Road Columbus, OH 43212William A. "Bud" Baeslack III Dean, College of Engineering The Ohio State University 142 Hitchcock Hall 2070 Neil Ave.
Columbus, Ohio 43210-1278Test, Research, and Training Reactor Newsletter University of Florida 202 Nuclear Sciences Center Gainesville, FL 32611 Mr. Andrew KauffmanMarch 29, 2007The Ohio State University Nuclear Reactor Laboratory 1298 Kinnear Road Columbus, OH 43212-1154
SUBJECT:
REQUEST FOR ASSURANCE OF DECOMMISSIONING FUNDING FORLICENSE RENEWAL FOR THE OHIO STATE UNIVERSITY (OSU) RESEARCH REACTOR (TAC NO. MA7724)
Dear Mr. Kauffman:
By letter dated July 26, 2006, OSU supplemented its license renewal application for theResearch Reactor to include financial information pertaining to operation and decommissioning of the reactor. This letter does not satisfy the requirements for assurance of decommissioning funding for license renewal. The position of the NRC is that OSU has assurance from the State of Ohio for decommissioning funding under the current license, but updated assurance of decommissioning funding is required for license renewal. Title 10 of the Code of Federal Regulations, Part 50.75(e)(iv) permits State licensees toprovide assurance of decommissioning funding by "a statement of intent containing a cost estimate for decommissioning, and indicating that funds for decommissioning will be obtained when necessary." The statement of intent must be signed by an official who has the authority to commit to spending the necessary funds to accomplish decommissioning, and it should be clearly asserted in the statement of intent that the signing official has that authority. In addition, the statement of intent should contain a statement that funding will be provided sufficiently in advance of decommissioning to prevent delay of required activities. If decommissioning funding is to continue to be assured by the State of Ohio, submit an updated statement of intent to this effect, signed by an appropriate State official. Otherwise, 10 CFR 50.75(e) provides alternate options for assurance of decommissioning funding.Please provide the necessary documentation within 30 days of the date of this letter. Inaccordance with 10 CFR 50.30(b), your response and the statement of intent must be executed in a signed original under oath or affirmation. If you have any questions, please contact William B. Kennedy at 301- 415-2784, or me at 301- 415-1631.Sincerely,/RA/Daniel E. Hughes, Project Manager Research and Test Reactors Branch A Division of Policy and Rulemaking Office of Nuclear Reactor RegulationDocket No. 50-150cc: See next pageDISTRIBUTION
- PUBLICPRTA r/fRidsNrrDprPrta Accession Number:ML070790519OFFICEPRTA:GEPRTA:LAOGCPRTA:BCPRTA:PMNAMEWKennedyEHyltonSUttal/NLODCollinsDHughesDATE 3/21/200703/22/200703/28/200703/29/200703/29/2007OFFICIAL RECORD COPY