ML070610496

From kanterella
Jump to navigation Jump to search
Summary of Handouts to Applicants (Folder 3)
ML070610496
Person / Time
Site: Peach Bottom  
Issue date: 01/29/2007
From: Vanwyen T
Exelon Generation Co
To: Todd Fish
Operations Branch I
Sykes, Marvin D.
Shared Package
ML060800089 List:
References
Download: ML070610496 (1)


Text

To:

T. Fish Fm:

M. Kelly, PBAPS Exam Author Subj.: Handouts provided to applicants for the written exam We provided the following materials to the applicants for administration of the written exam:

RO Exam

1. Full set of TRIPS with entry conditions blanked out:

0 T-1 00 "Scram" (1 sheet) 0 T-101 "RPV Control" (1 sheet) 0 T-102 "Primary Containment Control" (3 sheets) 0 T-103 "Secondary Containment Control" (1 sheet)

T-104 "Radioactivity Release" (1 sheet) 0 T-1 1 1 "Level Restoration" (1 sheet)

T-112 "Emergency Blowdown" (1 sheet) 0 T-116 "RPV Flooding" (2 sheets)

T-117 "LeveVPower Control" (1 sheet)

2. Steam Tables 3, Print E-1 (sheet 1 of 4) Single Line Diagram - Station
4. Table 2 "Cause & Corrective Action Trouble Shooting" of SO 62.1.A "Withdrawing/lnserting a Control Rod" SRO Exam
1.
2.
3.
4.
5.

Full set of Technical Specifications (without bases), with S.R. 3.6.4.1.4 (SBGT flow rate c 10,500 cfm) sanitized.

Full set of Technical Requirements (without bases)

SE-11 "Loss of Off-Site Power", Attachment C "Instrument List" Table PBAPS 3-1 : Emergency Action Level (EAL) Matrix of EP-AA-1007 "Radiological Emergency Plan Annex for Peach Bottom Atomic Power Station",

Rev. 13 OT-1 10, "Reactor High Level' Figure 1