CYAPCO FINAL STATUS SURVEY RELEASE RECORD CENTRAL PENINSULA SURVEY UNIT 9530-0001

2&

Prepared By:

FSS Engineer" Reviewed By.

Approved By:

Date:

Date: (0 Z3 c(.

Date:/1_

&d" S Engin r Technical Support Manager Revision 0

CENTRAL PENINSULA SURVEY UNIT 9530-0001 RELEASE RECORD TABLE OF CONTENTS

1.

SURVEY UNIT DESCRIPTION....................................................

3

2.

CLASSIFICATION BASIS..............................................................

3

3.

DATA QUALITY OBJECTIVES (DQO)........................................

5

4.

SURV EY DESIGN...........................................................................

8

5.

SURVEY IMPLEMENTATION.....................................................

11

6.

SURVEY RESULTS......................................................................

12

7.

QUALITY CONTROL....................................................................

15

8.

INVESTIGATIONS AND RESULTS............................................

16

9.

REMEDIATION AND RESULTS........................

...................... 16

10. CHANGES FROM THE FINAL STATUS SURVEY PLAN......... 16
11. DATA QUALITY ASSESSMENT (DQA).....................................

16

12. A N O M A LIES.................................................................................

17

13. CO N CLU SION...............................................................................

17

14. A TTA CHM EN TS..........................................................................

18 14.1 Attachment 1 - Figures (6 pages including cover) 14.2 Attachment 2 - Scan Results (3 pages including cover) 14.3 Attachment 3 - Laboratory Data (83 pages including cover) 14.4 Attachment 4 - DQA Results (14 pages including covers)

TOTAL 124 Revision 0

CENTRAL PENINSULA SURVEY UNIT 9530-0001 RELEASE RECORD SURVEY UNIT DESCRIPTION Survey Unit 9530-0001 (Central Peninsula) is designated as Final Status Survey (FSS) Class 2 and consists of 5,753 m2 (1.4 acres) of uninhabited open land located approximately 2,294 feet from the reference coordinate system benchmark used at Haddam Neck Plant (HNP) (see Attachment 1). The survey unit is bounded by land Survey Unit 9530-0004. The survey unit is relatively level open space in the middle of the peninsula.

The restoration of the peninsula for FSS has removed most surface interference in the survey unit; however, there are some trees and bushes remaining in the area.

The reference coordinates associated with this survey unit are E013 through E018 by S095 through S109 (refer to License Termination Plan (LTP) Section 5.4.4).

The reference coordinates provide the maximum dimensions of a rectangle containing this survey unit. Some areas contained in this rectangle may not be part of this survey unit.

The boundary of the survey unit was defined using a Global Positioning System (GPS) based on the Connecticut State Plane System North American Datum (NAD) 1927.

2.

CLASSIFICATION BASIS The survey unit was classified in accordance with Procedure RPM 5.1-10, "Survey Unit Classification. " The historical information, scoping analyses and characterization results provided sufficient data to designate Survey Unit 9530-0001 as Class 2 in August 2006.

The "Classification Basis Summary" conducted for Survey Unit 9530-0001 consisted of:

a) A review of the 10CFR50.75 (g) (1) database, b) A review of the "Initial Characterization Report" and the "Historic Site.

Assessment Supplement, "

c) Historic and current survey records review, d) Visual inspections and a "walkdown."

A review of the 10CFR50.75(g)(1) database report identified two documents associated with this survey unit.

a) Event PIR 80-37: Contamination was documented to be present in an area outside the restricted area. Small areas of low-level contamination were found on the facility grounds through a routine survey in a normally non-radioactive area.

b) Event PIR 89-35: Contamination was identified in the 115 kV switchyard moat (Structure 111, refer to Connecticut Yankee (CY)

Drawing SK-16112-10032 sheet 2.

The source of the contamination was the discharge of approximately fifty (50) gallons of radioactive liquid using an unmonitored, unmarked drain line in the Spent Fuel Building.

Once identified, decontamination was performed in the Revision 0 3

CENTRAL PENINSULA SURVEY UNIT 9530-0001 RELEASE RECORD switchyard moat and an outfall area outside the Radiologically Controlled Area (RCA). However, a plant survey performed on 2/28/89 shows that some of the radioactive material was deposited along the unpaved road in this survey unit. The survey also documents that the area was excavated and surveyed when the condition was identified.

The survey documents that count rates using portable beta detection instrumentation were less then one hundred corrected counts per minute above background (100 ccpm).

A review of the "Initial and Supplemental Characterization Reports" as well as the previous "Classification Basis Summaries" provided no additional information pertinent to classification.

The survey unit had undergone FSS in the fall of 2004 and release records documenting the satisfactory completion of the FSS objectives were in preparation.

In 2006, utilities were being removed as part of the decommissioning effort on the Upper Peninsula.

Construction debris including Asbestos Containing Material (ACM) was identified and remediated. In addition to the ACM, several objects were also identified that had detectable radioactivity. Two pieces of angle iron were located in a water utility trench in adjacent Survey Unit 9530-0004. Most of the work involved two areas adjacent to Survey Unit 9530-0001. Some of the excavated spoils from these areas were temporarily stored in Survey Unit 9530-0001 during the investigation. Based on the potential to change the final radiological status of the survey unit, another FSS was considered prudent to define the as-left radiological condition.

Soil samples were collected in 2006 to establish the radiological condition of the surface and subsurface area following removal of soil. Cs-137 was the only gamma emitting radionuclide reported in concentrations with the potential for exceeding the screening criteria.

Therefore, the previous FSS data and statistical parameters were used for the survey design.

Statistical quantities from the previous FSS survey are provided in Table 1.

Table I - Baic S**istica nities fon tepo FSSSurvey Minimum Observed Concentration (pCi/g):

6.39E-02 Maximum Observed Concentration (pCi/g):

3.15E-01 Mean (pCi/g):

1.61E-01 Median (pCi/g):

1.15E-01 Standard Deviation (pCi/g):

9.16E-02 Revision 0 4

Revision 0 4

CENTRAL PENINSULA SURVEY UNIT 9530-0001 RELEASE RECORD The FSS Engineer performed a visual inspection and walk-down during August 2006 to assess the physical condition of the survey unit, evaluate access points and travel paths and identify potentially hazardous conditions.

This survey area is affected by existing groundwater (reference CY memo ISC 06-024) which will be a source of dose from residual radioactivity, as discussed in Section 3 under the Data Quality Objectives.

Based upon the historical information and the results of radiological surveys performed during characterization, it was concluded that there was a low probability for residual radioactivity to be present in this survey unit in concentrations greater than the Operational Derived Concentration Guideline Levels (DCGLs) justifying a final survey unit classification of Class 2 (refer to Section 3).

3.

DATA QUALITY OBJECTIVES (DQO)

FSS design and planning used the Data Quality Objective (DQO) process as described by the LTP, Procedure RPM 5.1-11, "Preparation of Final Status Survey Plan, " and the "Multi-Agency Radiation Survey and Site Investigation Manual" (MARSSIM). A summary of the main features of the DQO process are provided herein.

The DQO process incorporated hypothesis testing and probabilistic sampling distributions to control decision errors during data analysis. Hypothesis testing is a process based on the scientific method that compares a baseline condition to an alternate condition. The baseline condition is technically known as the null hypothesis. Hypothesis testing rests on the premise that the null hypothesis is true and that sufficient evidence must be provided for rejection. In designing the survey plan, the underlying assumption, or null hypothesis was that residual activity in the survey unit exceeded the release criteria. Rejection of the null hypothesis would indicate that residual activity within the survey unit does not exceed the release criteria. Therefore, the survey unit does satisfy the primary objective of the FSS plan.

The primary objective of the FSS plan was to demonstrate that the level of residual radioactivity in Survey Unit 9530-0001 did not exceed the release criteria specified in the LTP and that the potential dose from residual radioactivity is As Low As Reasonably Achievable (ALARA).

A fundamental precursor to survey design is to establish a relationship between the release criteria and some measurable quantity. This is done through the development of DCGLs. The DCGLs represent average levels of radioactivity above background levels and are presented in terms of surface or mass activity concentrations. Chapter 6 of the LTP describes in detail the modeling used to develop the DCGLs for soil (called Base Case Soil DCGL), existing Revision 0 5

Revision 0 5

CENTRAL PENINSULA SURVEY UNIT 9530-0001 RELEASE RECORD groundwater radioactivity and future groundwater radioactivity that will be contributed by building basements and footings.

The DCGLs presented in Chapter 6 of the LTP were developed for exposures from three (3) components, that is, residual radioactivity in soil, existing groundwater radioactivity, and future groundwater radioactivity from the burial of concrete foundations or footings from site buildings containing residual radioactivity.

Equation 1 shows the mathematical relationship between the three (3) components and the total dose.

Equation 1 HTotal =Hsoil +HExistingGW +-HFutureGW The total dose under the LTP criteria is twenty-five (25) mrem/yr TEDE from all three (3) components.

The allowable total dose under the Connecticut Department of Environmental Protection (CTDEP) radiological remediation standard for CY is nineteen (19) mrem/yr TEDE. To satisfy both the LTP and CY CTDEP criteria, the dose from soil must be reduced when using the existing and future groundwater dose values discussed above.

This survey area is affected by existing groundwater (reference CY memo ISC 06-024).

Therefore, the dose contribution from existing groundwater is bounded by two (2) mrem/yr TEDE.

This survey unit is not considered impacted by future groundwater radioactive contamination, as there are no buried concrete foundations or footings containing residual radioactive material within the groundwater saturated zone in the area (reference CY memo ISC 06-024). The dose contribution from future groundwater, the third dose component is, therefore, zero (0) mrem/yr TEDE.

Equation 2 19 mrem/yrTotal = 17 mrem/yrsoil + 2 mrem/yrExisting GW+ 0 mrem/yrFutureGW The allowable dose for soil in this survey unit is seventeen (17) mrem/yr TEDE as shown by Equation 2 above.

The concentration of residual radioactivity resulting in seventeen (17) mrem/yr TEDE is designated as the Operational DCGL, and has been established for the radionuclides of concern as provided in Table 2.

Revision 0 6

Revision 0 6

CENTRAL PENINSULA SURVEY UNIT 9530-0001 RELEASE RECORD C-14 5.66E+00 3.85E+00 2.26E-01 Mn-54 1.74E+01 1.18E+O1 6.96E-01 Fe-55 2.74E+04 1.86E+04 1.1 OE+03 Co-60 3.81 E+00 2.59E+00 1.52E-01 Ni-63 7.23E+02 4.92E+02 2.89E+O1 Sr-90 1.55E+00 1.05E+00 6.20E-02 Nb-94 7.12E+00 4.84E+00 2.85E-01 Tc-99 1.26E+01 8.57E+00 5.04E-01 Ag-108m 7.14E+00 4.86E+00 2.86E-01 Cs-134 4.67E+00 3.18E+00 1.87E-01 Cs-137 7.91E+00 5.38E+00 3.16E-01 Eu-152 1.01E+01 6.87E+00 4.04E-0 1 Eu-154 9.29E+00 6.32E+00 3.72E-01 Eu-155 3.92E+02 2.67E+02 1.57E+01 Pu-238 2.96E+0 1 2.01 E+O1 1.1 8E+00 Pu-239/240 2.67E+01 1.82E+01 1.07E+00 Pu-241 8.70E+02 5.92E+02 3.48E+O 1 Am-241 (5) 2.58E+01 1.75E+01 1.03E+00 Cm-243/244 2.90E+01 1.74E+01 1.16E+00 (1) Bold indicates those radionuclides considered to be Hard-to-Detect (HTD)

(2) The Base Case Soil DCGLs for soil are specified by the LTP in Chapter 6 and are equivalent to 25 mrem/yr TEDE (3) The Operational DCGL is equivalent to 17 mrem/yr TEDE (4) The required MDC is equivalent to I mrem/yr TEDE (5) Americium-241 can be analyzed by gamma and alpha spectroscopy and is considered to be Easy to Detect (ETD); the preferred result is the alpha spectroscopy's when both analyses are performed Another important facet of the DQO process is to identify the radionuclides of concern and determine the concentration variability.

Soil samples were collected in 2006 to establish the radiological condition of the surface and subsurface area following removal of soil.

Cs-137 was the only gamma emitting radionuclide reported in concentrations with the potential for exceeding the screening criteria.

The previous FSS data and statistical parameters were used for the survey design and are provided in Table 1.

Instrument DQOs included a verification of the ability of the survey instrument to detect the radiation(s) of interest relative to the DCGL. Survey instrument Revision 0 7

Revision 0 7

CENTRAL PENINSULA SURVEY UNIT 9530-0001 RELEASE RECORD response checks were required prior to issue and after the instrument had been used. Control and accountability of survey instruments was required to assure the quality and prevent the loss of data.

As part of the DQOs applied to laboratory processes, analysis results were reported as actual calculated results. Results reported as less than Minimum Detectable Concentration (MDC) were not accepted for FSS.

Sample report summaries included unique sample identification, analytical

method, radionuclide, result, and uncertainty to two (2) standard deviations, laboratory data qualifiers, units, and the required and observed MDC.
4.

SURVEY DESIGN The level of effort associated with planning a survey is based on the complexity of the survey and nature of the hazards. Guidance for preparing FSS plans is provided in Procedure RPM 5.1-11, "Preparation of Final Status Survey Plans".

The FSS plan uses an integrated sample design that combines scanning surveys and sampling which can be either random or biased.

The DQO process determined that Cs-137 would be the radionuclide of concern in survey unit 9530-0001 (refer to Section 3). Other radionuclides identified during this FSS would be evaluated to ensure adequate survey design.

Surrogate DCGLs were not required for this survey unit based the previous FSS of this survey unit and via screening under LTP Section 5.4.7.2, "Gross Activity DCGLs".

Radionuclide screening or de-selection is a process where an individual radionuclide or aggregates may be considered insignificant and eliminated from the FSS. The criteria for de-selection are concentrations less than 5% for individual radionuclides and less than 10% for aggregates.

The Elevated Measurement Comparison (EMC) did not apply to this survey unit since it is a Class 2 area and discrete, elevated areas of contamination were not expected.

The Sign Test was selected as the non-parametric statistical test. The use of the Sign Test did not require the selection or use of a background reference area, which simplified survey design and implementation.

This approach was conservative since it included background Cs-137 as part of the sample set.

The number of soil samples for FSS was determined in accordance with Procedure RPM 5.1-12, "Determination of the Number of Surface Samples for Final Status Survey." The Lower Bound of the Gray Region (LBGR) was set in accordance with Procedure RPM 5.1-11 to 5.26 to maintain the relative shift (A/a) in the range of 1 and 3. The resulting Adjusted Relative Shift was 2.0. A Prospective Power Curve was generated using COMPASS, a software package developed under the sponsorship of the United States Nuclear Regulatory Commission (USNRC) for implementation of the MARSSIM in support of the decommissioning license termination rule (10 CFR 20, Subpart E). The result of the COMPASS computer run showed adequate power for the survey design.

Revision 0 8

CENTRAL PENINSULA SURVEY UNIT 9530-0001 RELEASE RECORD The survey design specified fifteen (15) surface soil samples for non-parametric statistical testing and two (2) samples at biased locations.

The grid pattern and locations of the soil samples were determined using Visual Sample Plan (VSP) in accordance with Procedure RPM 5.1-14, "Identifying, and Marking Surface Sample Locations for Final Status Survey."

Visual Sample Plan was created by Pacific Northwest National Laboratory (PNNL) for the United States Department of Energy. A systematic triangular grid pattern with a random starting point was selected for sample design, which is appropriate for a Class 2 area.

Judgmental sampling was included as a feature of this survey design to account for any anomalies potentially identified in the field.

Sample locations were identified using AutoCAD-LT, a commercially available plotting software package with coordinates consistent with the Connecticut State Plane System. These coordinates were integrated with a GPS to locate sample locations in the field. Sample Measurement Locations for the design are listed with the GPS coordinates in Table 3.

Table3 - Samp!le Measurement Locations with Associated GPS Coordinates1 Desigmaion i

Northing Ea4stinp 9530-0001-OOIF 235541.75 670285.43 9530-0001-002F 235541.75 670353.87 9530-0001-003F 235541.75 670422.31 9530-0001-004F 235541.75 670490.75 9530-0001-005F 235482.48 670388.09 9530-0001-006F 235482.48 670456.53 9530-0001-007F 235482.48 670524.97 9530-0001-008F 235482.48 670593.41 9530-0001-009F 235423.21 670490.75 9530-0001-01OF 235423.21 670559.19 9530-0001-01 IF 235423.21 670627.63 9530-0001-012F 235423.21 670696.07 9530-0001-013F 235423.21 670764.51 9530-0001-014F 235363.93 670661.85 9530-0001-015F 235363.93 670730.29 9530-0001-016F 235442.18 670580.76 9530-0001-017F 235463.77 670617.68 Procedure RPM 5.1-11 specifies that 5% of the samples are required to be selected for HTD analysis. Two (2) soil samples, or about 10% of the number of samples that would be used for non-parametric statistical testing were Revision 0 9

Revision 0 9

CENTRAL PENINSULA SURVEY UNIT 9530-0001 RELEASE RECORD randomly selected for HTD radionuclide analysis using the Microsoft Excel "RANDBETWEEN" function. Each sample was sent off-site for a full suite analysis of the HTD radionuclides specified in the LTP, Table 2-12, "Radionuclides Potentially Present at Haddam Neck Plant" and as provided in Table 2.

The implementation of quality control measures as referenced by Procedure RPM 5.1-24, "Split Sample Assessment for Final Status Survey," included the collection of two (2) soil samples for "split sample" analysis by the off-site laboratory. These locations were selected randomly using the Microsoft Excel "RANDBETWEEN" function. The number of quality control soil samples was about 10% of fifteen (15) samples.

The LTP specifies that scanning will be performed along with a combination of systematic and judgmental measurements (samples) for a Class 2 land area and should cover between 10% to 100% of the area.

The fraction of scanning coverage was determined during the DQO process with the total amount and location(s) based on the likelihood of finding elevated activity during FSS.

Based on the historical site assessment, the characterization data available, and the use of the survey unit to store spoils from remediation, it was determined that scanning was required in three (3) separate areas. The total surface area to be scanned was approximately 15% of the survey unit. A map of the scan grid locations is provided in Attachment 1.

For this Class 2 survey unit, the "Investigation Level" for area scanning and soil sample measurement results are those levels specified in LTP, Table 5-8. Table 4 provides a synopsis of the survey design.

Table 4 -Syno sisofthe S N e Desig n

Feature, Desig nCriteria

~

Basis Survey Unit Land Area 5,753 m2 Based on AutoCAD-LT Type I and Type 2 errors were 17 0.05, sigma was 0.092 pCi/g, Number of Measurements (15 systematic grid) the LBGR was adjusted to 5.2 (2 biased) to maintain Relative Shift in the range of 1 and 3 Grid Spacing 21.0 m Based on triangular grid Administratively set to achieve Operational DCGL 5.38 pCi/g Cs-137 17 mrem/yr TEDE (1)

The Operational DCGL meets Soil Investigation Level 5.38 pCi/g Cs-137 the LTP criteria for a Class 2 survey unit Revision 0 10

CENTRAL PENINSULA SURVEY UNIT 9530-000 1 RELEASE RECORD Scan Survey Area Coverage Approximately 15%

of the area I he LI P requires >1 U/

0% area coverage for Class 2 survey units Scan Detectable over Administratively set to achieve background 17 mrem/yr TEDE (1)

(1) The allowable dose for soil in this survey unit is 17 mrem/yr TEDE as the bounding dose from existing and future groundwater has been established based on field data (reference CY memo ISC 06-024)

5.

SURVEY IMPLEMENTATION Final status survey field activities were conducted under Work Plan and Inspection Record (WP&IR) 2006-0038.

The WP&IR package included a detailed FSS plan, job safety analysis, job planning checklist and related procedures for reference.

Daily briefings were conducted to discuss the expectations for job performance and the safety aspects of the survey. The "Daily Survey Journal" was used to document field activities and other information pertaining to the FSS.

Three (3) scan areas were established that constituted approximately 15% of the surface area of Survey Unit 9530-0001.

Grid lines, one meter wide, were painted on the ground of each of the three (3) scan areas. A background survey was performed around the survey unit and it was determined that, using a Eberline E-600 with a SPA-3 sodium iodide detector, background ranged from 6,200 counts per minute (cpm) up to 8,100 cpm.

The scan areas were established and each area was scanned for elevated readings (see Attachment 2 for all scan results). Scanning was performed with an Eberline E-600 using a SPA-3 sodium iodide detector.

The E-600 was operated in the rate-meter mode and used with audio response. The probe was positioned as close to the ground as possible and was moved at a scan speed of about 0.5 meters per second.

Approximately 15% of the survey unit was scanned.

Measurement locations were identified in North American Datum (NAD) 1927 coordinates using GPS coordinates; sample locations were identified and marked with a surveyor's flag or paint for identification.

At each sample location, a one (1) meter radius around the sample flag or paint mark was scanned for elevated radiation levels.

Fifteen (15) surface soil samples were collected and packaged in accordance with Haddam Neck Plant (HNP) Procedure RPM 5.1-3, "Collection of Sample Media for Final Status Survey" and FSS design.

Samples were controlled, transported, stored, and transferred to the off-site laboratory using Chain-of-Custody (COC) protocol in accordance with Procedure RPM 5.1-5, "Chain of Custody for Final Status Survey Samples."

Revision 0 I1I Revision 0 11

CENTRAL PENINSULA SURVEY UNIT 9530-0001 RELEASE RECORD Two (2) samples (9530-0001-003F and 9530-0001-008F) were randomly selected for HTD radionuclide analysis.

The implementation of survey specific quality control measures included the collection of two (2) samples (9530-0001-006F and 9530-0001-014F) for "split sample" analysis.

6.

SURVEY RESULTS All field survey activities were conducted between September 8, 2006 and September 15, 2006.

The sample locations identified in the FSS plan were scanned over approximately a one (1) meter radius for elevated radiation levels. Table 5 provides an overview of the scan results for sample measurement locations.

Scan results are provided in Attachment 2.

'rable 5 -Scan Results for Sample Measurevment Locations Measurement Reading evepm

> Action L~eNel

<Location (kcpm)'~

,kp) 1 6.74 8.48 NO 2

7.06 10.4 NO 3

6.55 9.25 NO 4

8.62 8.70 NO 5

7.77 8.72 NO 6

7.53 8.63 NO 7

8.41 8.40 YES 8

7.87 9.60 NO 9

7.18 8.74 NO 10 7.87 8.93 NO 11 7.44 8.57 NO 12 7.47 8.81 NO 13 7.26 8.48 NO Revision 0 12

CENTRAL PENINSULA SURVEY UNIT 9530-0001 RELEASE RECORD Table 5, - Scan Results for Sample Measurement Locations Sample Highbest Logg-ced Measurement Reaidings Action Level

>Action LeNel~

SLocationW (kcpm) 2~

kp 14 7.17 8.88 NO 15 8.45 9.29 NO 16 8.27 8.70 NO 17 7.86 9.42 NO (1) The action level is based on a measurement above ambient background in accordance with the FSS plan (2) The FSS plan requires movement of the sample measurement location to the area within the 1 meter radius yielding the response above the action level Three (3) areas, that comprised approximately 15% of the total surface area for the survey unit, were scanned for elevated radiation levels. The areas were scanned in accordance with the FSS plan on September 15, 2006.

One (1) elevated measurement location was identified during scanning. A confirmatory sample was collected at the elevated measurement location.

The sample collected at the elevated measurement location was denoted as 9530-0001-018F.

A map identifying all of the sample locations is provided in Attachment 1.

Table 6 provides an overview of the scan area survey. Scan results are provided in Attachment 2.

nTable 6-ScanA Hig~hest

.S...i Logged Action Level(*).-

Investigation Ara,

RaI,-

Reading ame (kcpm)

Identification (2)ple None - no 1

7.38 8.93 elevated areas None identified 2

10.6 7.98 ER-02-01-1 9530-0001-018F None - no 3

6.99 7.73 elevated areas None L

_identified (1) The action level is based on a measurement above ambient background (2) ER is an abbreviation associated with the barcodes used in the field where ER stands for Elevated Reading The off-site laboratory employed for the radiological analyses of samples was General Engineering Laboratories, LLC, Charleston, South Carolina.

The laboratory analyzed the fifteen (15) samples collected for non-parametric statistical testing, the associated field splits, the two (2) biased samples, and the one (1) confirmatory sample using gamma spectroscopy. Gamma spectroscopy analysis was performed to the required MDCs. Gamma spectroscopy results identified some radionuclides meeting the accepted criteria for detection (i.e., a result greater than two standard deviations uncertainty).

Revision 0 13

CENTRAL PENINSULA SURVEY UNIT 9530-0001 RELEASE RECORD Cs-137 was identified in fourteen (14) of the fifteen (15) samples collected for non-parametric statistical testing.

Cs-137 was the primary radionuclide confirming the DQOs. The mean of the gamma spectroscopic analysis results for the sample population indicated that Cs-137 was present at levels lower than the concentrations of Cs-137 found in soil at off-site locations within the vicinity of the HNP as presented in the Health Physics TSD BCY-HP-0063.

A summary of the fifteen (15) samples collected for non-parametric statistical testing results is provided in Table 7.

9530-0001-001F 1.30E-01 0.024 9530-0001-002F 1.27E-01 0.024 9530-0001-003F 2.59E-01 0.048 9530-0001-004F 1.31E-01 0.024 9530-0001-005F 4.85E-02 0.009 9530-0001-006F 1.21E-01 0.022 9530-0001-007F 1.34E-01 0.025 9530-0001-008F 1.33E-01 0.025 9530-0001-009F 6.41E-02 0.012 9530-0001-O0OF 1.34E-01 0.025 9530-0001-011 F 1.06E-01 0.020 9530-0001-012F 8.50E-02 0.016 9530-0001-013F 7.29E-02 0.014 9530-0001-014F 5.47E-02 0.010 9530-0001-015F 4.15E-02 0.008 (1) The Operational DC( L trom Table 2 is 5.38 pC1/g tor Cs-137 to achieve 17 mrem/yr TEDE The off-site laboratory also processed two (2) samples for HTD analysis as required by the sample plan.

The requested analyses included alpha spectroscopy, gas proportional counting, and liquid scintillation depending on the radionuclide and the measurement method. All analyses met the required MDC.

Revision 0 14

CENTRAL PENINSULA SURVEY UNIT 9530-0001 RELEASE RECORD As previously stated in Section 4 of this report, the criteria for de-selection of a radionuclide is a concentration that is less than 5% of the Operational DCGL for individual radionuclides and less than 10% of the Operational DCGLs for aggregates. Sr-90 and Pu-238 were the only HTDs, which by analysis, met the criteria for detection (i.e., a result greater than two standard deviations uncertainty).

The highest result for both Sr-90 and Pu-238 was <1% of the Operational DCGL.

9530-0001-008F 2.67E-03 0.003 1.02E-01 0.005 (1) The Operational DCGL from Table 2 is 1.05 pCi/g for Sr-90 and 20.1 pCi/g for Pu-238 to achieve 17 mrem/yr TEDE Two (2) biased samples were collected at locations selected by FSS Supervision based on professional judgment and observation. Gamma spectroscopy analysis was performed by the off-site laboratory to the required MDC.

9530-0001-017F 1.82E-01 0.034 (1) The Operational DCGL from Table 2 is 5.38 pCi/g for Cs-137 to achieve 17 mrem/yr TEDE

7.

QUALITY CONTROL The off-site laboratory processed the split samples and performed gamma spectroscopy analysis. Thirteen percent (13%) of the samples were selected for analysis, which exceeds the 5% minimum required by the LTP. The data were evaluated using USNRC acceptance criteria specified in Inspection Procedure 84750 as detailed in HNP Procedure RPM 5.1-24, "Split Sample Assessment for Final Status Survey."

There was acceptable agreement between field split results for Cs-137 at location 9530-0001-006.

However, Cs-137 was not detected in sufficient quantities in the field split results at location 9530-0001-014 to evaluate in accordance with procedure. Evaluation using the reported results for K-40 resulted in acceptable agreement between the field split results at location 9530-0001-014.

The sample analysis vendor, General Engineering Laboratories, LLC, maintains quality control and quality assurance plans as part of normal operation. Refer to for data and data quality analysis results.

Revision 0 15

CENTRAL PENINSULA SURVEY UNIT 9530-0001 RELEASE RECORD

8.

INVESTIGATIONS AND RESULTS One (1) confirmatory sample was collected in scan area 2 at a location exhibiting elevated scan readings. The sample is denoted as shown in Table 6, with the sample result shown in Table 10 below.

Table 10 - Cofirtniat'oyy Sample Resuths,

~Sam~e~umbe I Cs4137

~ ~Fraction of the Sarnle umbr 1)'i/ I pera~tional DCGL~

9530-0001-018F 1.67E-01 0.031 (1) The Operational DCGL from Table 2 is 5.38 pCi/g for Cs-137 to achieve 17 mrem/yr TEDE

9.

REMEDIATION AND RESULTS Historically, no radiological remedial action as described by MARSSIM Section 5.4 was performed in this survey unit prior to or as a result of the FSS. Health Physics TSD BCY-HP-0078, "ALARA Evaluation of Soil Remediation in Support of Final Status Survey, " determined that remediation beyond that required to meet the release criteria is unnecessary and that the remaining residual radioactivity in soil was ALARA.

10.

CHANGES FROM THE FINAL STATUS SURVEY PLAN No changes were made to the FSS plan.

11.

DATA QUALITY ASSESSMENT (DQA)

The DQO sample design and data were reviewed in accordance with Procedure RPM 5.1-23, "Data Quality Assessment, " for completeness and consistency.

The sampling design had adequate power as indicated by the Retrospective Power Curve. The Sign Test was performed on the data and compared to the original assumptions of the DQOs. The evaluation of the Sign Test results demonstrates that the survey unit passes the unrestricted release criteria, thus, the null hypothesis is rejected.

Documentation was complete and legible. Surveys and sample collection were consistent with the DQOs and were sufficient to ensure that the survey unit was properly designated as Class 2.

The preliminary data review consisted of calculating basic statistical quantities (e.g., mean, median, standard deviation). The mean and median values are well below the Operational DCGL when used in conjunction with the unity rule.

Also, the retrospective power curve shows that a sufficient number of samples were collected to achieve the desired power. Therefore, the survey unit meets the unrestricted release criteria with adequate power as required by the DQOs.

Revision 0 16 Revision 0 16

CENTRAL PENINSULA SURVEY UNIT 9530-0001 RELEASE RECORD For Cs-137, the range of the data, about four (4) standard deviations, was not a particularly large variation considering that the levels were essentially at existing environmental levels where such variation is to be expected.

The difference between the mean and median was -21% of the standard deviation which indicates some skewness in the data.

The data was represented graphically through posting plots, a frequency plot, and a quantile plot. The frequency plot indicates positive skewness as confirmed by the calculated skew of 1.3.

All data, assessments, and graphical representations are provided in Attachment 4.

12.

ANOMALIES No anomalies were noted.

13.

CONCLUSION Survey Unit 9530-0001 has met the final DQOs of the FSS plan. The ALARA criteria for soils as specified in Chapter 4 of the LTP were achieved. Elevated Measurement Comparison and remediation was not required.

Cs-137 was used for statistical testing to determine the adequacy of the survey unit for FSS.

The sample data passed the Sign Test. The null hypothesis was rejected.

The Retrospective Power Curve generated using COMPASS shows adequate power was achieved. The survey unit is properly designated as Class 2.

The dose contribution from soil is less than 1 mrem/yr TEDE based on the average concentration of the samples used for non-parametric statistical sampling.

This survey area is affected by existing groundwater (reference CY memo ISC 06-024); therefore the dose contribution from existing groundwater is bounded at two (2) mrem/yr TEDE.

This survey unit is not considered impacted by future groundwater radioactive contamination, as there are underground structures, systems or components containing residual radioactive material within the groundwater saturated zone in the area (reference CY memo ISC 06-024); therefore, the dose contribution from future groundwater is zero (0) mrem/yr TEDE.

The average total dose from residual radioactivity in this survey unit, including exposures from the three (3) components as described in Section 3, that is, residual radioactivity in soil, existing groundwater radioactivity, and future groundwater radioactivity from the burial of concrete foundations or footings from site buildings containing residual radioactivity, will not exceed 3 mrem/yr TEDE.

Therefore, Survey Unit 9530-0001 is acceptable for unrestricted release.

Revision 0 17 Revision 0 17

CENTRAL PENINSULA SURVEY UNIT 9530-0001 RELEASE RECORD

14.

ATTACHMENTS 14.1 Attachment 1 - Survey Unit Location Map 14.2 Attachment 2 - Scan Results 14.3 Attachment 3 - Laboratory Results 14.4 Attachment 4 - DQA Results Revision 0 18 Revision 0 18

CENTRAL PENINSULA SURVEY UNIT 9530-0001 RELEASE RECORD ATTACHMENT 1 (FIGURES)

I j-coNntcVT AIVZ-r 0

Connecticut Yankee Atomic Power Company EV Site Map With Reference To Survey Unit 9530-0001 III

4..K 13 112 4

6 7

11 15

= Wetrand S-Samj*LOCafee

  • I6 10 1l 9

0 37.5 65 Feet Coarmkft mcw NA27CoftvSM 5

Connecticut Yankee Atomic Power Company Survey Unit 9530-0001 Final Status Survey Design

0.08 0.13 0.04

- WtLaid 0.10 0.13 0.26 0.06 0.13 0

37.5 65

! Fet 0.12 NOWdaI3 cMOC101m 0.

Connecticut Yankee Atomic Power Company Survey Unit 9530-0001 FinalStatus Survey Cs-137Posting Plot

A; - WatLand F2

-ScmAm 0

-sMnkLVud 0

37.5 65 iýFee Scan Area 1 Notcs Bodw-dww hu 6.2kqmn b

&I--FM

. by=i BEM0 i P-hI Refrso7k, e

-Wnf Connecticut Yankee Atomic Power Company Survey Unit 9530-0001 Final Status Survey Scan Awas

Scan Area 2 K

7ý-

WetLzd M

0 375 65 NoWi Recbfrto Th*d.9fter ed ampkiwatm~d Tab 10 for iljecwzfmuoy auk*iinuh Scan Area 1 Connecticut Yankee Atomic Power Company Survey Unit 9530-0001 Biased and Confnlatwy Samples

CENTRAL PENINSULA SURVEY UNIT 9530-0001 RELEASE RECORD ATTACHMENT 2 (SCAN RESULTS)

Survey Release Record Sample Location Scan Results Survey Unit 9530-0001 Sample Name 9530-01-SL-00-01-0 9530-01-SL-00-02-0 9530-01-SL-00-03-0 9530-01-SL-00-04-0 9530-01-SL-00-05-0 9530-01-SL-00-06-0 9530-01 -SL-00-07-0 9530-01 -SL-00-08-0 9530-01-SL-00-09-0 9530-01-SL-00-10-0 9530-01 -SL-00-1 1-0 9530-01-SL-00-12-0 9530-01 -SL-00-1 3-0 9530-01-SL-00-14-0 9530-01-SL-00-15-0 9530-01-SL-00-16-0 9530-01-SL-00-17-0 9530-01-ER-02-01-1 (1)

Background

(C~m) 7270 9080 7980 7470 7490 7410 7190 8300 7510 7680 7350 7570 7270 7640 8020 7470 8140 6800 Action Level 8488 10441 9256 8704 8726 8639 8401 9601 8748 8931 8574 8812 8488 8888 9299 8704 9428 7978 Results Above Log Date Log Time E600 SIN Probe SIN (cPm) 6740 7060 6550 8620 7770 7530 8410 7870 7180 7870 7440 7470 7260 7170 8450 8270 7860 10600 AL 9/8/2006 9/8/2006 9/8/2006 9/8/2006 9/8/2006 9/8/2006

+

9/8/2006 9/12/2006 9/14/2006 9/12/2006 9/12/2006 9/12/2006 9/14/2006 9/14/2006 9/14/2006 9/12/2006 9/12/2006 10:05:00 10:08:00 10:16:00 10:25:00 10:32:00 10:38:00 11:01:00 8:04:00 8:06:00 8:17:00 8:24:00 8:28:00 8:01:00 7:55:00 7:58:00 10:27:00 10:17:00 1116 1116 1116 1116 1116 1116 1116 1116 1105 1116 1116 1116 1105 1105 1105 1116 1116 1006 1006 1006 1006 1006 1006 1006 1006 1012 1006 1006 1006 1012 1012 1012 1006 1006 1012

+

9/15/2006 11:28 AM 1105 (1) Elevated reading corresponds to confirmatory sample location 9530-0001-018 AL - Action Level

Survey Release Record Scan Area Results Survey Unit 9530-0001 9530-0001 SCAN AREA 1 Sample Name

Background

Action Level (CPM) fcPM) 9530-01-SC-01-01-0 6220 7346 9530-01-SC-01-02-0 7390 8618 9530-01-SC-01-03-0 7300 8520 9530-01-SC-01-04-0 7680 8931 9530-01-SC-01-05-0 7240 8455 Results 6860 7220 7330 7380 6970 Above AL Log Date Log Time E600 S/N Probe S/N 9/15/2006 9/15/2006 9/15/2006 9/15/2006 9/15/2006 8:20:00 8:26:00 8:32:00 8:37:00 8:43:00 1105 1105 1105 1105 1105 1012 1012 1012 1012 1012 9530-0001 SCAN AREA 2 9530-01 -SC-02-01-0 6

9530-01-ER-02-01-1 6.

9530-01 -SC-02-02-0 7:

9530-01 -SC-02-03-0 7'

9530-01 -SC-02-04-0 8

9530-01 -SC-02-05-0 7'

9530-01-SC-02-06-0 7

9530-0001 SCAN AREA 3 9530-01 -SC-03-01-0 6

9530-01-SC-03-02-0 6.

9530-01-SC-03-03-0 6

9530-01-SC-03-04-0 6

9530-01-SC-03-05-0 6

9530-01-SC-03-06-0 6

9530-01 -SC-03-07-0 6

9530-01-SC-03-08-0 6

800 800 240 030 120 600 480 7978 7978 8455 8227 9407 8845 8715 6150 10600 6120 6430 6200 7740 6530 9/15/2006 9/15/2006 9/15/2006 9/15/2006 9/15/2006 9/15/2006 9/15/2006 9:57:00 11:28:00 10:09:00 10:16:00 10:20:00 10:24:00 10:28:00 1105 1105 1105 1105 1105 1105 1105 1012 1012 1012 1012 1012 1012 1012 710 390 550 790 480 570 560 710 7880 7532 7706 7967 7630 7727 7717 7880 6690 6770 6280 6630 6600 6990 6210 6780 9/15/2006 9/15/2006 9/15/2006 9/15/2006 9/15/2006 9/15/2006 9/15/2006 9/15/2006 10:48:00 10:51:00 10:54:00 10:56:00 10:58:00 11:01:00 11:03:00 11:06:00 1105 1105 1105 1105 1105 1105 1105 1105 1012 1012 1012 1012 1012 1012 1012 1012 AL - Action Level

CENTRAL PENINSULA SURVEY UNIT 9530-0001 RELEASE RECORD ATTACHMENT 3 (LABORATORY DATA)

General Narrative',

1

CASE NARRATIVE For CONNECTICUT YANKEE RE: Soil PO# 002332 Work Order: 172114 SDG: MSR#06-1276 September 27, 2006.

Laboratory Identification:

General Enineering Laboratories, LLC Mailing Address:

P.O. Box 307 12 Charleston. South Carolina 29417 Express Mail Delivery and Shipping Address:

2040 Savage Road Charleston, South Carolina 29407 Telephone Number:

(843) 556-8171 Summary:

Sample receipt The sample(s) for this Project arrived at General Engineering Laboratories, LLC, (GEL) in Charleston, South Carolina on September 20, 2006. All sample containers arrived without any visible signs of tampering or breakage. The chain of custody contained the proper documentation and signatures.

The laboratory received the following sample(s):

Sample ID Client Sample ID 1721.14001 9530-0001-008F 172114002 9530-0001-01OF 172114003 9530-0001-01 IF 172114004 9530-0001-012F 172114005 9530-0001-016F 172114006 9530-0001-017F 172114007 9530-0001-018F 172114008 9530-0001-001F 172114009 9530-0001-002F GIENERAL ENGINEERING LABORATORIES, LLC a Member of THE GEL GROUP, INC.

P.O. Box 30712

  • Charleston, SC 29417 - 2040 Savage Road (29407)

Phone (843) 556-8171, Fax (843) 766-1178. www.gel.com

172114010 9530-0001-003F 172114011 172114012 172114013 172114014 172114015 172114016 172114017.

172114018 172114019 1721.1402'0 9530-0001-004F 9530-0001-005F 9530-0001-006F 9530-0001-006FS 9530-0001-007F 95-30-0001-009F 9530-0001-013F 9530-0001-014F 9530-0001-014FS

.9530-0001-0 15F Items of Note:

There are no items of note.

Case Narrative:

Sample analyses were conducted using methodology as outlined in General Engineering Laboratories (GEL) Standard Operating Procedures. Any technical or administrative problems during analysis. data review, and reduction are listed below by analytical

.parameter.

Analytical Request:

Eighteen soi samples :were analyzed for FSSGAM.

Two soil samples were analyzed for FSSALL.

Internal Chain of Custody:

Custody was maintained for the sample(s).

Data Packame:

The enclosed data package contains the following sections: Case Narrative, Chain of Custody and Supporting Documentation and all analytical, fractions, I certify that this data package is in compliance with the SOW,-both technically and for completeness, for other than the conditions detailed above. Release of the data contained in this hard copy data packagehas been authorized by the Laboratory Manager or a designee, as verified by the following signature.

Cheryl Jones Project Manager GENDE-RAL ENGINEERING LABORATORIES, LLC a Member of THE GEL GROUP, INC.

P.O. Box 30712

  • Charleston, SC 29417
  • 2040 Savage Road (29407)

Phone (843) 556-8171

  • Fax (843) 766-1178 ° www.gel.com

List of current GEL Certifications as of 26 September 2006 State Alaska Arizona Arkansas California Colorado Connecticut Dept. of Navy EPA Florida*/ELAP Georgia Hawaii Idaho Illinois Indiana Kansas Kentucky Louisiana

Maryland, Massachusetts Michigan Nevada New Jersey New Mexico New York North Carolina Certification UST-062 88-0651

. 42DO904046 01 Ii ICA GenEngLabs PH-0169 NFEsc 41 i WG-15J E87156 E87 156 (FUNELAP)

N/A

N/A 200029 C-SC-01 E-10332

..90129 03046 270 M-SCOI2 9903 SC 12 SCO02 FL NELAP E97156 11501 233 North Carolina Drinking W 45709 North Dakota-R-158 Oklahoma 9904 Pennsylvania 68-00485 South Carolina 101200061 1058500 1t10120002 Tennessee 02934 Texas TX213-2006A Texas NELAP T104704235-06-TX U.S. Dept. of Agriculture S-52597 US Army Corps of Engineer N/A Utah 8037697376 GEL Vermont VT87156 Virginia Washington 00151 Cl641 4

Chain of Custody And oSuprting.

Documentation 5

Health Physics Procedure GPP-GGG R-R5 104-003-Attachment B-CY-001 Major Chain of Custody Form No. 2006-00565 Connecticut Yankee Atomic Power Company 362 Injun Hollow Road, East Hampton, CT 06424 860-267-2556 Project Name: Haddam Neck Decommissioning Analyses Requested Lab Use Only Contact Name & Phone:

Comments:

Jack McCarthy 860-267-3924 Analytical Lab (Name, City, State)

General Engineering Laboratories 2040 Savage Road. Charleston SC. 29407 cj 843 556 8171. Attn. Cheryl Jones V)

Priority: 1130 D. Z 14 D. 117 D. 13 D.

Container 1-4 ILA Sample Size-Sample Designation Date Time Media Type

&Type Comment, Preservation Lab Sample ID Code Code Code 9530-0001-008F 9-/Z-0 oSp' ao TS G

BP X..

9530-0001-O0OF 0.0'/-P/

o,,/7 TS G

BP X

9530-0001-011F 0P oz, TS G

BP X

9530-0001-012F f-1zo

-/

TS G

BP X

9530-0001-016F q.-/.f-0

/00Z TS G

BP X

9530-0001-017F

.-dz -oC v

/l/ol TS G

BP X

4 4

.4 4

4

.4.

4 I

.1 S-.-.------L-----..-J.

I 4

4 4

4 4

4.-4 L

~

I

-J _________

.1 ______

.4. ____

.4 ______

L _____

i L...........................L...................L, I

NOTES: PO #: 002332 MSR #: 06- /276 SSWP# NA Z LTP QA E1 Radwaste QA 11 Non QA Samples Shipped Via:

E Fed Ex.

-1 ups F-1 Hand 0

Other

-Rill o*f Lntina "*

Internal Container Temp.: __ Deg.

C Custody Sealed?

YE NE Custody Seal Intact?

YO NO

1) Relinquishedy Date/Time
2) Received By Date/Time
3) Relinquished By Date/Time
4) Received By.

Date/Time

Health Physics Procedure GPP-GGGR-R5104-003-Attachment B-CY-00 1 Major Chain of Custody Form No. 2006-572 Connecticut Yankee Atomic Power Company 362 Injun Hollow Road, East Hampton, CT 06424 860-267-2556 Project Name: Haddam Neck Decommissioning Analyses Requested Lab Use Only Contact Name & Phone:

Comments:

Jack McCarthy 860-267-3924 Media Sample Container Code Type Size*

Analytical Lab (Name, City, State):

Code

&Type

~~~Code General Engineering Laboratories Cod 2040 Savage Road Charleston, SC 29407 ATT: Cheryl Jones (843-556-8171)

Priority: Fi 30 D. E 14 D. El 7 D.

Other:"_

Sample Designation Date Time Comment, Preservation Lab Sample ID 9530-0001-018F 9/15/06 1130 TS G

BP X

NOTES: PO #: 002332 MSR #: 4y-Ig'76 E

LTP QA Li Radwaste QA EL Non QA Samples Shipped Via:

Internal Container Fed Ex Temp.:.*),.Deg. C

  • .{..

Li-ups__

"" l Hand Custody Sealed?

1) eli quished By D te/lime/

2)r Div..-

Dae/Time Custody Seal Intact?

5), Re*lnuished By..

19

(

--i"Other

/3)'R' 'fiBle B

L Date/Time'

4) Received By Date/Time Y 0 N

-*/**,.~~~il of La

.. t.

.*.ding

5) Relinquished-By Date/Time
6) Received By i'

"".Date/Time

Health Physics Procedure GPP-GGGR-R5104-003-Attachment B-CY-00 I Major h inof C. stody Form No. 2006-00575 Connecticut Yankee Atomic Power Company C

362 Injun Hollow Road, East Hampton, CT 06424 860-267-2556 Project Name: Haddam Neck Decommissioning Analyses Requested Lab Use Only, Contact Name & Phone:

Comments:

Jack McCarthy 860-267-3924 Analytical Lab (Name, City, State)

General Engineering Laboratories 2040 Savage Road. Charleston SC. 29407 843 5568171. Attn. CherylJones Priority: E] 30 D. E 14 D. [_

7 D. [

3 D.

Container Sample Size-,

Sample Designation Date Time Media Type

&Type Comment, Preservation Lab Sample ID Code Code Code..

9530-0001-001F 9/8/06 1006 TS G

BP.

X 9530-0001-002F 9/8/06 1010 TS G

BP X

9530-0001-003F 9/8/06 1016 TS G

BP X

9530-0001-004F 9/8/06 1026 TS G

BP X

9530-0001-005F 9/8/06 1033 TS G

BP X

9530-0001-006F

.9/8/06 1039 TS G

BP X

9530-0001-006FS 9/8/06 1039 TS G

BP X

NOTES: PO #: 002332 MSR #: 06-/z74' SSWP# NA Z LTP QA D Radwaste QA LI Non QA Samples Shipped Via:

Internal Container

]

Fed Ex Temp.: _

Deg.

El ups C

E. l Hand Custody Sealed?

YLI ND]

Relinq*uCsseody Seal

1) Relinqushe.

Date/Time

2) Received~y Date/Time Custody Seal 1/'

7?

~

,.~/;,

E~lI Other*

Intact?

3). Relinquished By Date/Time

4) Received By..
  • -Date/Time Y LI NO Bill of Lading #

.5) Relinquished By Date/Time

6) Received By Date/Time

Health Physics Procedure GPP-GGGR-R5104-003-Attachment B-CY-00 1 Major Chain of Custody Form No. 2006-00576 Connecticut Yankee Atomic Power Company 362 Injun Hollow Road, East Hampton, CT 06424 860-267-2556 Project Name: Haddam Neck Decommissioning Analyses Requested LabUse Only Contact Name & Phone:

Comments:

Jack McCarthy 860-267-3924 Analytical Lab (Name, City, State)

General Engineering Laboratories 2040 Savage Road. Charleston SC. 29407 843 556 8171. Attn. Cheryl Jones C/)

Priority: II 30 D. Z 14 D. El 7 D. ] 3 D.

Container Sample Size"Cmet rsrato a

apeI Sample Designation Date Time Media Type

&Type Comment, Preservation Lab Sample ID Code Code Code 9530-0001-007F 9/8/06 1101 TS G

BP X

9530-0001-009F 9/8/06 1436 TS G

BP X

9530-0001-013F 9/8/06 1413 TS G

BP X

9530-0001-014F 9/8/06 1417 TS G

BP X

9530-0001-014FS 9/8/06 1417 TS G

BP X

9530-0001-015F 9/8/06 1402 TS G

BP X

NOTES: PO #: 002332 MSR #: 06-t'776 SSWP# NA Z LTP QA E] Radwaste QA "l

Non QA Samples Shipped Via:

Internal Container

  • Fed Ex Temp.: _2 Deg.

D uPs C

El Hand Custody Sealed?

YE NE5

1) Reli ed Date/Time
2) Received By Date/Time Custody Seal T"

7 y,.p, 3 1'f]

Other Intact?

3) Relinquished By Date/Time
4) Received By Date/Time Y

YE N E Bill of Lading #

5) Relinquished By Date/Time
6) Received By Date/Time

Connecticut Yankee Statement of Work for Analytical Lab Services CY-ISC-SOW-O01 Figure 1. Sample Check-in List L

Date/Time Received: 7 6

SDG#:

Work Order Number:

2- (i' 1, ft~

ftl

?3fl""

Shipping Container ID: 7-95 g/1l Y/

7 l

1.

Custody Seals oif shipping container intact?

2..

Custody Seals dated and signed?

3.

Chain-of-Custody record present?

4.

Cooler temperature PP-

5.

Vermiculite/packing materials is:

6.'

Number of samples in shipping container:

7.

Sample holding times exceeded?

- 0 &, e; (0

Chain of Custody # 0ý0.61-Yes

-<No fj fZ/

Yes-['-. o [-,.

Yes [4No [I Wet I Dry[<ýr Yes

I NO 1.8. Samples have:

II e

.......hazard labels V "custody seals

. */appropriate sample labels

9. Samples are:

in good condition leaking

-broken

-have air bubbles 10.

II.

Were any anomalies identified in sample receipt?

Yes[ J No [

  • Description of anomalies (include sample numbers):

Sample Custodian/Laboratory:

/7-'

Date. /0 o

o6a.

Telephoned to:.

On By

RADiOLOGICAL

.ANALYS I.S....

11

Radiochemistry Case Narrative Connecticut Yankee Atomic Power Co. (YANK)

Work Order 172114 Method/Analysis Information Product:

Alphaspec Am241, Cm, Solid ALL FSS DOE EML HASL-300, Am-05-RC Modified Analytical Method:

Prep Method:

Dry Soil Prep GL-RAD-A-021 Method:

Analytical Batch Number:

Prep Batch Number:

Dry Soil Prep GL-RAD-A-021 Batch Number:

  • Ash Soil Prep Dry Soil Prep 572120.

570846 570843 Sample ID 172114001 172114010 1201191303 1201.191304.

.1201191305 1201191306 Client ID.

'9530-0001-008F 9530-0001-003F Method Blank (MB) 172114001 (9530-0001-008F) Sample Duplicate (DUP) 172114001 (9530-0001-008F) Matrix Spike (MS)

Laboratory Control Sample (LCS)

SOP Reference Procedure for preparation, analysis and reporting of analytical data are controlled by General Engineering Laboratories, LLC as Standard Operating Procedure (SOP). The data discussed in this narrative has been analyzed in accordance with GL-RAD-A-01 I REV# 14.

Calibration Information:

Calibration Information All initial and continuing calibration requirements have been met.

Standards Information Standard solution(s) for these analyses are NIST traceable and used before the expiration date(s).

Sample Geometry All counting sources were prepared in the same geometry as the calibration standards.

12

Ouality Control (0C) Information:

Blank Information The blank volume is representative of the sample volume in this batch.

Designated QC The following sample was used for QC: 172114001 (9530-0001-008F).

QC Information.

All of the QC samples met the required acceptance limits.

Technical Information:

Holding Time.

All sample procedures for this sample set were performed within the required holding time.

Preparation Information All preparation criteria have been met for these analyses.

Sample Re-prep/Re-analysis None of the samples in this sample set required reprep or reanalysis.

Miscellaneous Information:.

NCR Documentation Nonconformance -reports are generated to document any procedural anomalies that may deviate from

.referenced SOP or contractual documents. A nonconformance report (NCR) was not generated for this SDG.

Manual Integration No manual integrations were performed on data in this batch.

Additional Comments Additional comments were not required for this sample set.

Gualifier information Manual qualifiers were not required.

Method/Analysis Information 13

Product:

AIphaspec Pu, Solid-ALL FSS Analytical Method:

DOE EML HASL-300, Pu-I I-RC Modified Prep Method:

Dry Soil Prep GL-RAD-A-021 Method:

Analytical Batch Number:

Prep Batch Number:.

Dry Soil Prep GL-RAD-A-021 Batch Number:

Ash Soil Prep Dry Soil Prep 572121 570846 570843 Sample ID 172114001.

172114010.

1201191308 1201191309

  • 1201191310 Client ID) 9530-0001 -008F 9530-0001 -003F M*ethod Blank

,.'VIB)'

172114001(9530-0001-008F) Sample Duplicate (DUP) 172114001(9530-0001-008F) Matrix Spike (MS)

Laboratory Control Sample (LCS)

SOP Reference Procedure for preparation,analysis and reportingof analytical data are controlled by General Engineering Laboratories, LLC as Standard 00erating Procedure (SOP). The data discussed in this narrative has been analyzed in accordance with GL-RAD-A-01 I REV# 14.

Calibration Information:

Calibration Information All initial and continuing calibration requirements have been met.

Standards Information Standard solution(s) for these analyses are NIST traceable and used before the expiration date(s).

Sample Geometry All counting sources were prepared in the same geometry as the calibration standards.

Quality Control (OC) Information:

Blank Information The blank volumeis representative of the sample volume in this batch.

Designated QC The following sample was used for QC: 172114001 (9530-0001-008F).

QC Information All of the QC samples met the required acceptance limits.

14

Technical Information:

Holding Time All sample procedures for this sample set Were performed within the required holding time.

Preparation Information All preparation criteria have been met for these analyses.

Sample Re-prep/Re-analysis None of the samples in this sample set required reprep.or reanalysis.,

Miscellaneous Information:

NCR Documentation Nonconformance reports are.generated to document any procedural anomalies that may deviate from referenced SOP or contractual documents. A nonconformance report (NCR) was not generated for this SDG.

Manual integration No manual integrations were performed on data in this batch.

Additional Comments Additional comments were not required for this sample set.

Qualifier information manual qualifiers were not required.

Method/Analysis Information Product:

Liquid Scint Pu241, Solid-ALL FSS DOE EML HAS L-300, Pu-11I-RC Modified Analytical Method:

Prep Method:

Dry Soil Prep GL-RAD-A-02 i Method:

Analytical Batch Number:

Prep Batch Number:

Dry Soil Prep GL-RAD-A-021 Batch Number:

Ash Soil Prep Dry Soil Prep 572122 570846 570843 15

Sample ID Client ID 172114001 9530-0001-008F 172114010 9530-0001-003F 1201191311 Method Blank (MB) 1201191312 172114001(9530-0001-008F) Sample Duplicate (DUP) 1201191313 172114001(9530-0001-008F) Matrix Spike (MS) 1201191314 Laboratory Control Sample (LCS)

SOP Reference Procedure for preparation, analysis and reporting of analytical data are controlled by General Engineering Laboratories, LLC as Standard Operating Procedure (SOP). The data discussed in this narrative has been analyzed in accordance with GLýRAD-A-035 REV# 8.

Calibration Information:

Calibration Information All initial and continuing calibration requirements have been met....

Standards Information Standard solution(s) for these analyses are NIST traceable and used before the expiration date(s).

Sample Geometry All counting sources were prepared in the same geometry as the calibration standards.

tQuality Control Qoc) Information:

Blank Information The blank volume is representative of the sample volume in this hatch.

Designated QC The following sample was used for QC: 172114001 (9530-0001-008F).

QC Information All of the QC samples met the required acceptance limits.

Technical Information:

Holding Time All sample procedures for this sample set were performed within the required holding time.

Preparation Information All preparation criteria have been met for these analyses.

Sample Re-prep/Re-analysis None of the samples in this sample set required reprep or reanalysis.

Miscellaneous Information:

NCR Documentation Nonconformance reports are generated to document any procedural anomalies that may deviate from 16

referenced SOP or contractual documents. A nonconformance report (NCR) was not generated for this SDG.

Manual Integration No manual integrations were performed on data in this batch.

Additional Comments Additional comments were not required for this sample set.

Qualifier information.

Manual qualifiers were not required.

Method/Analysis Information Product:

Analytical Method:

Prep Method:

Analytical Batch Number:

Prep Batch Number:

GammaSolid-FSS GAM & ALL FSS 226 Ingrowth Waived EML HASL 300, 4.5.2.3 Dry Soil Prep 574334 570843 17

Sample ID 172114001 172114002 172114003 172114004 172114005 172114006 172114007

.172114008

.172114009 172114010 172114011 1721140123 172114013 172114014 172114015 172114016 172114018.

172114018 172114019 172114020 1201196533 1201196534

.1201196535 Client ID 9530-00011-008F 9530-0001-01 OF 9530-0001-01 IF 9530-0001-012F 9530-0001-016F 9530-0001'-017F 9530-0001-018F 9530-0001-001 F 9530-0001-002F 9530-0001-003F 9530-0001-004F 9530-0001-005F 9530-0001-006F 9530-0001-0-6FS 9530-0001-007F 9530-0001-009F 9530-0001-013F 9530-0001-014F 9530-0001-014FS

  • 9530-0001-015F Method Blank (MB) 172114006(9530-0001.-01 7F) Sample Duplicate (DUP)

Laboratory Control Sample (LCS)

SOP Reference Procedure for preparation, analysis and reporting of analytical data are controlled by General Engineering Laboratories, LLC as Standard Operating Procedure (SOP).The data discussed in this narrative has been analyzed in accordance with GL-RAD-A-013 REV# 12.

Calibration Information:

Calibration Information All initial and continuing calibration requirements have been met.

Standards Information Standard solution(s) for these analyses are NIST traceable and used before the expiration date(s).

Sample Geometry All counting sources were prepared in the same geometry as the calibration standards.

Guality Control (OC) Information:

Blank Information The blank volume is representative of tIE sample volume in this batch.

Designated QC The following sample was, used for QC: 172114006 (9530-0001-017F).

18

QC Information All of the QC samples met the required acceptance limits.

Technical Information:

Holding Time All sample procedures for this sample set were performed within the required holding time.

Preparation Information All preparation criteria have been met for these analyses.

Sample Re-prep/Re-analysis None of the samples in this sample set required reprep or reanalysis.

Miscellaneous Information:

NCR Documentation Nonconformance reports are generated to document any procedural anomalies that may deviate from.

referenced SOP or conuractuai documents. A nonconformance report (NCR) was not generated for this SDG.

Additional Comments Additional comments were not required for this sample set.

Qualifier information Qualifier Reason Analyte Sample U'

ui Data rejected due to interference.

Data rejected due to low abundance.

Manganese-54 Cesium-134 172114013 172114001 1721.14002 172114006 172114012 172114013 172114015 172114019 172114017 Cobalt-60 Niobium-94 1201196534 Ul Data rejected due to no valid peak.

Bismuth-2 12 172114005 Method/Analysis Information 19

Product:

GFPC, Sr90, solid-ALL FSS Analytical Method:

EPA 905.0 Modified Prep Method:

Dry Soil Prep GL-RAD-A-021 Method:

Analytical Batch Number:

Prep Batch Number:

Dry Soil Prep GL-RAD-A-021 Batch Number:

Ash Soil Prep Dry Soil Prep 571177 570846 570843

.Sample ID II7I0UUI 172114010 1201189312

.1201189313 1201189314 1201189315 Client ID 9.30-0001-008F 9530-0001-003F Method Blank (MB) 172114001(9530-0001-008F) Sample Duplicate (DUP) 172114001(9530-0001-008F) Matrix Spike (MS)

Laboratory Control Sample (LCS)

SOP Reference Procedure for preparation, analysis and reporting of analytical data are controlled by General Engineering Laboratories, LLC as.Standard Operating Procedure (SOP). The data discussed in this narrative has been analyzed in accordance with GL-RAD-A-004 REV# 10.

Calibration Information:

Calibration Information All initial and continuing calibration requirements have been met.

Standards Information Standard solution(s) for these analyses are NIST traceable and used before the expiration date(s).

Sample Geometry All counting sources were prepared in the same geometry as the calibration standards.

Quality Control (QC) Information:

Blank Information The blank volume is representative of the sample volume in this batch.

Designated QC The following sample was used for QC: 172114001 (9530-0001-008F).

QC Information 20

All of the QC samples met the required acceptance limits.

Technical Information:

Holding Time All sample procedures for this sample set were performed within the required holding time.

Preparation Information All preparation criteria have been met. for these analyses..

Sample Re.prep[Re-analysis.

None of the samples in this sample set required reprep or reanalysis.

Chemical Recoveries All chemical recoveries: meet the required acceptance limits for this sample set.

Miscellaneous Information:

NT.'

NCRDocumentation Nonconformance reports are generated to document any procedural anomalies that may deviate from referenced SOP or contractual documents. A nonconformance report (NCR) was not generated for this SDG.

Additional Comments Additional comments were not required for this sample set.:.

Oualifier information Manual qualifiers were not required.

Method/Analysis Information Product:

Liquid Scint Tc99, Solid-ALLIFSS Analytical Method:

Analytical Batch Number:

Sample ID 172114001 172114010 1201188784 1201188785 1201188786 1-701188787 DOE EML HASL-300, Tc-02-RC Modified 570932 Client ID 9530-0001-008F 9530-0001-003F Method Blank (MB) 172114001(9530-0001-008F) Sample Duplicate (DUP) 172114001(9530-0001-008F) Matrix Spike (MS)

Laboratory Control Sample (LCS) 21

SOP Reference Procedure for preparation, analysis and reporting of analytical data are controlled by General Engineering Laboratories, LLC as Standard Operating Procedure (SOP). The data discussed in this narrative has been analyzed in accordance with GL-RAD-A-005 REV# 13.

Calibration Information:

Calibration Information.

All initial and continuing calibration requirements have been met.

Standards Information Standard solution(s) for these analyses are NIST traceable.and used before the expiration date(s).

Sample Geometry All counting sources were prepared in the same geometry as the calibration standards.

Quality Control (QC Information:

Blank Information The blank volume is representative of the sample.volumes in this batch.

Designated QC The following sample.was used for QC: 172114001 (9530-0001-008F).

QC Information All of.the QC samples met the required acceptance limits.

Technical Information:

Holding Time All sample procedures for this sample set were performed within the required holding time.

Preparation Information All preparation criteria have been met for these analyses.

Sample Re-prep/Re-analysis The batch was recounted due to a suspected blank false positive.

Miscellaneous Information:

NCR Documentation Nonconformance reports are generated to document any procedural anomalies that may deviate from referenced SOP or contractual documents. A nonconformance report (NCR) was not generated for this SDG.

Additional Comments Additional comments were not required for this sample set.

22

Qualifier information Manual qualifiers were not required.

Method/Analysis Information Product:

Liquid Scint Fe55, Solid-ALL FSS DOE RESL Fe-I, Modified.

Analytical Method:

Prep Method:

.Dry Soil Prep GL-RAD-A-02 i Method:

Analytical Batch Number:

Prep Batch Number:

Dry Soil.Prep GL-RAD-A-021 Batch Number:

Ash Soil Prep Dry Soil Prep 570929

.570846 570843.

Sample ID 172114001

.172114010 12011188775.

1201188776:

1201188777 1201188778 Client ID 9530-0001 008F

  • 9530-0001-003F Method Blank (MB).

1172114010(9530-00011-003F) Sample Duplicate (DUP) 172114010(9530-0001-003F) Matrix Spike (MS)

Laboratory Control Sample (LCS)

SOP Reference Procedure for preparation, analysis and reporting of analytical data are controlled by General Engineering Laboratories, LLC as Standard Operating Procedure (SOP). The data discussed in this narrative has been analyzed in accordance with GL-RAD-A-040 REV# 3.

Calibration Information:

Calibration Information All initial and continuing calibration requirements have been met.

Standards Information Standard solution(s) for these analyses are NIST traceable and used before the expiration date(s).

Sample Geometry All counting somces were prepared in the same geometry as the calibration standards.

Ouality Contrl (0C) Information:

Blank Information The blank volume is representative of the sample volumes in this batch.

23

Designated QC The following sample was used for QC: 172114010 (9530-0001-003F).

QC Information All of the QC samples met the required acceptance limits.

Technical Information:

Holding Time All sample procedures for this sample set were performed within the required holding time.

Preparation Information All preparation criteria:have been met for these analyses.

Sample Re-prep/Re-analysis.

Samples 1201188775 (MB) and 1721 14001 (9530-0001-008F) were recounted due to the quench number being outside the calibration range.

Miscellaneous Information:

NCR Documentation Nonconformance reports are generated to document any procedural anomalies that may deviate from referenced.SOP or contractual documents. A nonconformance report (NCR) was not generated for this SDG..

Additional Comments Additional comments were not required for this sample set.

Oualifier information Manual qualifiers were not required.

Method/Analysis Information Product:

Liquid Scint Ni63, Solid-ALL FSS Analytical Method:

DOE RESL Ni-I, Modified Prep Method:

Ash Soil Prep Dry Soil Prep GL-RAD-A-021 Method:

Dry Soil Prep Analytical Batch Number:

570930 Prep Batch Number:

570846 Dry Soil Prep GL-RAD-A-021 Batch Number:

570843 24

Sample ID Client ID 172!14001 9530-0001-008F 172114010 9530-0001-003F 1201188780 Method Blank (MB) 1201188781 172114010(9530-0001-003F) Sample Duplicate (DUP) 1201188782 172114010(9530-0001-003F) Matrix Spike (MS) 1201188783 Laboratory Control Sample (LCS)

SOP Reference Procedure for preparation, analysis and reporting of analytical data are controlled by General Engineering Laboratories, LLC as Standard Operating Procedure (SOP). The data discussed in this narrative has been analyzed in accordance with GL-RAD-A-022 REV# 8.

Calibration Information:

Calibration Information All initial and continuing calibration requirements have been met.

Standards Information Standard SOlution(s)for these analyses are NIST traceable and used before the expiration date(s).

Sample Geometry All counting sources were prepared in the same geometry as the calibration standards.

Quality Control (QC) Information::

Blank Information The blank volume is representative of the sample volume in this batch.

Designated QC The following sample was used for QC: 172114010 (9530-0001-003F).

QC Information All of the QC samples met the required acceptance limits.

Technical Information:

Holding Time All sample procedures for this sample set were performed within the required holding time.

Preparation Information All preparation criteria have been met for these analyses.

Sample Re-prep/Re-analysis None of the samples in this sample set required reprep or reanalysis.

Miscellaneous Information:

NCR Documentation Nonconformance reports are generated to document any procedural anomalies that may deviate from 25

referenced SOP or contractual documents. A nonconformance report (NCR) was not generated for this SDG.

Additional Comments Additional comments were not required for this sample set.

Qualifier information Manual qualifiers were not required.

Method/Analysis Information Product:.

LSC, Tritium Dist, Solid-HTD2,ALL FSS Analytical Method:

Analytical Batch Number:

Sample ID 172114001 172114010 1 2 0 1 1 8 8 7 8 8 1201188789 1201188790 1201:188791 EPA 906.0 Modified 570933 Client ID 9530-0001-008F 9530-0001 -003F, Method Blank (MB):

172114001:(9530-0001-008F) Sample Dupiicate :(DUP) 1721.14001!(95.30-0001-:008F.) Matrix Spike (MS)

Laboratory Control Sample (LCS)

SOP Reference.

Procedure for preparation, analysis and reporting. of analytical data are controlled by General Engineering Laboratories, LLC asStandard Operating Procedure (SOP). The data discussed in this narrative has been analyzed in accordance with GL-RAD-A-002 REV# 13.

Calibration Information:

Calibration Information All initial and continuing calibration requirements have been met.

Standards Information Standard solution(s) for these analyses are NIST traceable and used before the expiration date(s).

Sample Geometry All counting sources were prepared in the same geometry as the calibration standards.

Quality Control (OCt Information:

Blank Information The blank volume is representative of the sample volume in this batch.

26

Designated QC The following sample was used for QC: 172114001 (9530-0001-008F).

QC Information All of the QC samples met the required acceptance limits.

Technical Information:

Holding Time All sample procedures for this sample set were performed within the required holding time; Preparation Information All preparation criteria have been met for these analyses.

Sample Re-prepfRe-analysis...

None of thesamples in this sample set required reprep or reanalysis.

Miscellaneous Information:

NCR Documentation Nonconformance reports are generated to document any procedural anomalies that may deviate from referenced SOP or contractual documents. A nonconformance report (NCR)was not generated for this SDG.

Additional Comments Additional comments were not required for this sample set.

Oualifier information Manual qualifiers were not required.

Method/Analysis Information Product:

Liquid Scint C14, Solid AlI,FSS Analytical Method:

Analytical Batch Number:

Sample ID 172114001 172114010 1201188792 1201188793 1201188794 1201188795 EPA EERF C-01 Modified 570934 Client ID 9530-0001 -008F 9530-0001-003F Method Blank (MB) 172114010(9530-0001-003F) Sample Duplicate (DUP) 1721 14010(9530-0001-003F) Matrix Spike (MS)

Laboratory Control Sample (LCS) 27

SOP Reference Procedure for preparation, analysis and reporting of analytical data are controlled by General Engineering Laboratories, LLC as Standard Operating Procedure (SOP). The data discussed in this narrative has been analyzed in accordance with GL-RAD-A-003 REV# 8.

Calibration Information:

Calibration Information All initial and continuing calibration requirements have been met.

Standards Information Standard solution(s) for these analyses are NIST traceable and used before the expiration date(s).

Sample Geometry All counting sources were prepared in the same geometry as the calibration standards.

Quality Control(OC) Information:..

Blank Information The blank volume is representative of the sample volume in this batch.

Designated QC The following sample. was used for QC: 1721140 (9530-70001-003F).

QC Information All of the QC samples met the required acceptance limits.,

Technical Information:

Holding Time

  • All sample procedures for this sample set were performed within the required holding time.

Preparation Information.

All preparation criteria have been met for these analyses.:

Sample Re-prep/Re-analysis None of the samples in this sample set required reprep or reanalysis.

Miscellaneous Information:

NCR Documentation Nonconformance reports are generated to document any procedural anomalies that may deviate from referenced SOP or contractual documents. A nonconformance report (NCR) was not generated for this SDG.

Additional Comments Additional comments were not required for this sample set.

28

Oualifier information Manual qualifiers were not required.

Certification Statement Where the analytical method has been performed under NELAP certification, the analysis has met all of the requirements of the NELAC standard unless otherwise: noted in the analytical case narrative.

Review Validation:.

GEL requires all analytical data to be verified by a qualified data validator. In addition, all data designated for CLP or CLP-like packaging will receive a third level validation upon completion of the data package.

The following data validator verified the information presented in this case narrative:

Reviewer/Date:

'LI~N 10Q-o 29

SAMPLE DATA

SUMMARY

30

GENERAL ENGINEERING LABORATORIES, LLC 2040 Savage Road Charleston SC 29407 - (843) 556-8171 - www.gel.com Certificate of Analysis Report for YANKOOI Connecticut Yankee Atomic Power Co.

Client SDG: MSR#06-1276 GEL Work Order: 172114 The Qualifiers in this report are defined as follows:

A quality control analyte recovery is outside of specified acceptance criteria Analyte is a surrogate compound U

Analyte was analyzed for, but not detected above the MDL, MDA, or LOD.

UI Gamma Spectroscopy--Uncertain identification ND The analyte concent-rirat;on is not det cted a*b the detection

  • ,..,uo,, the detctionu, limfiit.

The above sample is reported on a dry weight basis except where prohibited by the analytical procedure.

Where the analytical method has been performed under NELAP certification, the analysis has met all of the requirements of the NELAC standard unless qualified on the Certificate of Analysis.

This data report has been prepared and reviewed in accordance with General Engineering Laboratories, LLC standard operating.procedures, Please direct any questions to your Project Manager, Cheryl Jones.

Reviewed by 31

GENERAL ENGINEERING LABORATORIES, LLC 2040 Savage Road Charleston SC 29407 - (843) 556-8171 - www.gel.corn Certificate of Analysis Company : Connecticut Yankee Atomic Power Address:

362 Injun Hollow Rd

Contact:

Project:'

East Hampton. Connecticut 06424 Mr. Jack McCarthy Soils PO# 0(P-332.

Report Date:

October 4. 2006 Client Sample ID:

9530-00017-008F Project:

YANK01204 SamplelD:

172114001 ClientlD:

YANK001 Matrix:

TS Vol. Recv.:

Collect Date:

12-SEP-06 Receive Date:

20-SEP-06 Collector:

Client Moisture:

17.4%

Parameter Qualifier Result Uncertainty LC TPU MDA Units DF Analyst Date Time Batch Mt Rad Alpha Spec Analysis Alphaspec A.241. Cm SolidlALL FSS Americium-241 U

0.0864 Cirium9242 u

.U0.00 Curium -23/24, U

0.0664 Alphaspec Pu, Solid-ALL FSS Plutonium-238 U

0.102 Plutonium-239/240 U

0.062 Liquid Scint Pti241, Solid-ALL FSS Plutonium-241 U

6.10 Rad Gamma Spec Analysis Gainma,Solid-FSS GAM.& ALL FSS 226 Ingrowth Waived Actinium-228 0.837 Americium-241 U -0.00443 Bismuth-212 0.605 Bismuth-214 0.635 Cesium-134 UI 0.00 Cesium-137 0.133 Cobalt-60 U

0.0125 EfropiUm-!52 U

-0.0255 Europium-154 U -0.0496 Europium-155 U

0.0653 Lead-212 0.816 Lead-214 0.666 Manganese-54 U

0.0204 Niobium-94 U

0.00376 Potassium-40 12.7 Radium-226 0.635 Silver-108m U 0.000126 Thallium-208 0.238 Rad Gas Flow Proportional Counting GFPC. Sr90, solid-ALL FSS Strontium-90 U

0.00276

+

Rad Liquid Scintillation Analysis "

LSC, Tritimn Dist, Solid-HTD2,ALL FSS Tritium U

-5.59

.4-/L0. 105

+./-0.05153,

  • /-w0.0911 0.0409 0.00 0.0334

.+!-0.106

+/-0.0553

+/--0.0915 0.153 0.0765 0

o138 0.118 0.101 p.CilgO pCi/g pCi/0 pCilga

+1-0.0996 0.0285

+/-0.100

+/-0.077.

.0.0202 +/-0.0773

+/-8.99 7.27

+/-9.01 15.3 pCi/g

+!-0.199

+/-0.117

+/-0.281

+/-0.114

+/-0.0308

+/-0.0359

+/-0.0201

+--0.0596

+/-0.0802

+/-0.0758

+/-0.0879

+/-0.104

+/-0.0255

+/-0.0207

+/-1.23

+/-0.114

+/-0.0199

+/-0.0479 0.0592 0.0646 0.150 0.0342 0.0246 0.0188 0.0184 0.0506 0.0523 0.0553 0.0301 0.0355 0.0225 0.0176 0.159 0.0342 0.0171 0.0198

+1-0.199

+/-0.117

+/-0.281

+/-0.114

+/-0.0308

+/-0.0359

+1-0.0201

+/-0.0596

+/-0.0802

+/-0.0758

+/-0.0879

+1-0.104

+/-0.0255

+1-0.0207

+1-1.23

+/-0.114

+/-0.0199

+/-0.0479 0.129 0.133 0.319 0.0727 0.0522 0.0401 0.0407 0.106 0.115 0.114 0.0625 0.0746 0.0478 0.0375 0357 0.0727 0.0362 0.0419 0.0111 pci/ga pCilgo pcilgC pCi/g pCi/g pCi/g pCi/ga pCi/g pCi~q pCi/g0 pCi/ga pCi/g-pCi/g0 pCi/g pC'Jg-TC1 09/28/06 1156 572120 TCI 09/28/06 0935 572121 TCI 09/29/06 2158 572122 MJHI 10/02/06 0545 574334

/

KSDI 09/29/06 2335 571177 5

DFAI 09/25/060210 570933 6

/-0.00637 0.00516+/-0.00637

+1-7.85 6.93

+1-7.85 14.8 pCi/g 32

GENERAL ENGINEERING LABORATORIES, LLC 2040 Savage Road Charleston SC 29407 - (843) 556-8171 - www.gel.com Certificate of Analysis Company:

Connecticut Yankee Atomic Power Address 362 Injun Hollow Rd East Hampton. Connecticut 06424

Contact:

Mr. Jack McCarthy Project:

Soils PO# 002332 Report Date: October 4, 2006 Client Sample ID:

Sample. ID:

9530-0001-008F 172114001 Protect:

Client ID:

.Vol. Recv.:

YANK01204.

YANKOO I Parameter Qualifier Result Uncertainty LC TPU MDA Units DF Analyst Date Time Batch Ml Rad Liquid Scintillation Analysis Liquid Scint C14, Solid All, FSS Carbon-14 *U 0.00533

+/-0.0803 0.0671 +/-0.0803 0.142:.

pCi/g AXD2 09/23/06 1427 570934.

Liquid Scint Fe55, Solid-ALL FSS Iron-55.

U 3.66

+1-45.4 31.9 44-45.4 66.3 pCi/g MXPI 10/03106 0521 570929 Lqiaid Scint Ni63 Solid-ALL FSS Nickel-63

.U 4.44

+/410.8 8.84.

+/-i0.8 "18.6 pCi.

MXPI 09/25/06 1618 570930 1

Liquid Scint Tc99. Solid-ALL MSS Techtnetiunm-99 U.

0.0384

+/-0.285 0.238

.+/-0.285 0.491 pCi/*

KXRI 09i29)/06 1617 570932 1 The following Prep Methods were performed Method Description Analyst

-Date. "

Time.

Prep Batch Dry Soil Prep Dry Soil Prep GL-RAD-A-021 LXM2 09/20/06 1528 570843 The following Analytical Methods were performed.

Method Description 1

DOE EML HASL-300, Am-05-RC Modified 2

DOE EML HASL-300, Pu-I I-RC Modified 3

DOE EML HASL-300, Pu-I I-RC Modified 4

EML HASL 300, 4.5.2.3 5

EPA 905.0 Modified 6

EPA 906.0 Modified 7

EPA EERF C-01 Modified 8

DOE RESL Fe-1, Modified 9

DOE RESL Fe-I, Modified 10 DOE RESL Ni-I, Modified 11 DOE EML HASL-300, Tc-02-RC Modified 12 DOE EML HASL-300, Tc-02-RC Modified Surrogate/Tracer recovery Test Recovery%

Acceptable Limits Americium-243 Plutonium-242 Carrier/Tracer Recovery Carrier/Tracer Recovery Carrier/Tracer Recovery Alphaspec Am241, Cm, Solid ALL Alphaspec Pu, Solid-ALL FSS Liquid Scint Pu241, Solid-ALL Fý GFPC, SO9O, solid-ALL FSS Liquid Scint Fe55, Solid-ALL FS 92 102 96 89 74 (15%-125%)

(15%-125%)

(25%-125%)

(25%-125%)

(15%-125%)

33

GENERAL ENGINEERING LABORATORIES, LLC 2040 Savage Road Charleston SC 29407 - (843) 556-8171 - www.gel.com Certificate of Analysis Company:

Connecticut Yankee Atomic Power Address:

362 Injun Hollow Rd East Hampton, Connecticut 06424 Report Date: October 4, 2006

Contact:

Mr. Jack McCarthy

.Project:

Soils PO#.002332 Client Sample ID:

9530-0001-008F Project:

YANKO 1204 SamplelD:

  • 172114001 Client ID:

YANK001 Vol. Recv.:

Parameter Qualifier Result Uncertainty LC TPU M])A Units DF Analyst Date Time Batch Mt Carrier/Tracer Recovery Liquid Scint Ni63, Solid-ALL FS 73 (25%-125%)

Carrier/Tracer Recovery Liquid Scint Tc99. Solid-ALL FS 75

. (15%-125%)

Notes:

The Qualifiers in this report are defined as follows.:

SA quality control analyte recovery is outside of specified acceptance criteria Result is less than value reported Resultis greater than value rep6rted A

The TIC is a suspected aldol-condensation product B

Target analyte was detected in the associated blank BD Results are either below the MDC or tracer recovery is low C

Analyte has been confirmed by GC/MS analysis D

Results are reported from a diluted aliquot of the sample H

Analytical holding time was exceeded J

Value is estimated N/A Spike recovery limits do not apply.. Sample concentration exceeds spike concentration by 4Xor more R

Sample results are rejected U

Analyte was analyzed for, but not detected above the MDL, MDA, or LOD.

UT Gamma Spectroscopy-Uncertain identification X

Consult Case Narrative, Data Summary package, or Project Manager concerning this qualifier Y

QC Samples were not spiked with this compound A

RPD of sample and duplicate evaluated using +/-RL. Concentrations are <5X the RL h

Preparation or preservation holding time was exceeded The abovc sample is reported on a dry weight basis.

34

GENERAL ENGINEERING LABORATORIES, LLC 2040 Savage Road Charleston SC 29407 - (843) 556-8171 - www.gel.com Certificate of Analysis Company Connecticut Yankee Atomic Power Address:

362 Injun Hollow Rd East Hampton, Connecticut 06424

Contact:

Mr. Jack McCarthy Project:

Soils PO# 002332 Report Date: October 4, 2006 Client Sample ID:

Sample ID:

Matrix:

Collect Date:

Receive Date:

Collector:

Moisture:

9530-0001-01 OF 172114002 TS 12-SEP--06 20-SEP-0-6 Client 20.6%

Proiect:

YANKO 1204 Client ID:

YANK001 Vol. Recv.:

Parameter..

Qualifier.

Result Uncertainty LC TPU MtDA Units DF Analyst Date Time.Batch Mt, Rad Gamma Spec Analysis Gamtma Solid-FSS GAM & ALL FSS 226 Ingrowth Waived ActiniUm-228 0.708

+/-0.178 Americium-241 U

-0.027

+/-0.125 Bismuth-212 0.501

+/-0.263 Bismuth-214 0.637

+/-0.0916 Cesium-134 UT 0.00

+/-0.0379 Cesium-137 0.134

+/-0.0319 Cobalt-60

.U

-0.00423.

+/-0.0199

.Europium-152 U

0.00262

+/-0.0477 Europium-154 U -0.00925

+/-0.0555 Europium-155 U

0.0469

+/-0.0598 Lead-212 0.825

+/-0.0608 Lead-214 0.745

+/-0.0721 Manganese-54 U

0.00196

+/-0.0197 Niobium-94 U

-0.004

+/-0.0166 Potassium-40 13.4

+/-0.858 Radium-226 0.637

+/-0.0916 Silver-108m U 0.000472

+/-0.0173 Thallium-208 0.258

+/-0.0406 0.0507 0.0897

  • 0.114 0.0323 0.0214 0.0163 0.0165 0.0407 0.0463 0.0524 0.0233 0.0279 0.0166 0.0139 0.155 0.0323 0.0145 0.0165

,+/-0.178

+/-0.125

+/-0.263

+/-0.0916

+/-0.0379

+4-0.0319

+/-0.0 199

+/-0.0477

+/-0.0555

+/-0.0598

+/-0.0608

+/-0.0721

+/-0.0197

+/-0.0166

+/-0.858

+/-0.0916

+/-0.0173

+/-0.0406 0.108 0.185 0.242 0.0675 0.0447 0.0343

.0.0356 0.0849.

0.0997 0.108 0.0484 0.0584 0.0351 0.0294 0.336 0.0675 0.0303 0.0347 pCi/g-pCilg*

pCi/g pCi/ga pCi/g.:

pCi/g-pCi/g" pCi/g2 pci~a pug/.

pCug.

pCilga pGig.

pCi/ga pCU.g MJHI1 10/02/06.0545 574334

.1.

The following Prep Methods were performed Method Description Analyst Date Time Prep Batch D*y Soil Prep Dry Soil Prep GL-RAD-A-021 LXM2 09/20/06 1536 570843 The following Analytical Methods were performed Method Description I

EML HASL 300,4.5.2.3 Notes:

The Qualifiers in this report are defined as follows

  • f A quality control analyte recovery is outside of specified acceptance criteria Result is less than value reported 35

GENERAL ENGINEERING LABORATORIES, LLC 2040 Savage Road Charleston SC 29407 - (843) 556-8171 - www.gel.com Certificate of Analysis Company:

Connecticut Yankee Atomic Power Address :.

362lnjun Hollow Rd.

East Hampton, Connecticut 06424 Report Date: October 4. 2006

Contact:

Mr. Jack McCarthy Project:

Soils PO# 002332 Client Sample ID.

9530-0001-OIOF Proiect:

YANK01204 Sample ID:.

172114002 Client ID:

YANK001:

Vol. Recv.:

P rQualifier Result Usncertatinty LC TIPU M4DA Units DF Analyst Date Time Batch Mt Result is greater than value reported A

The TIC is..a suspected aldol-condensation product B

Target analyte was detected in the associated blank BD Results are either below the MDC or tracer recovery is low C

Analyte hasý been confirmed by GC/MS analysis D

Results are reported from a diluted aliquot of the sample H

Analytical holding time was exceeded J

Value is estimated N/A Spike recovery limits do not apply. Sample concentration exceeds spike concentration by 4X or more R

Sample results are rejected U.Anilyte was analyzed.for, but not detected above the MDL, MDA, or LOD.

UI Gamma Spectroscopy--Uncertain identification

-X Consult Case Narrative, Data Summary package, or Project Manager concerning this qualifier Y

QC Samples were not spiked with this compound.

A RPD of sample and duplicate evaluated using +/-RL. Concentrations are <5X the RL h

Preparation or preservation holding time was exceeded The above sample is reported on a dry weight basis.

36

GENERAL ENGINEERING LABORATORIES, LLC 2040 Savage Road Charleston SC 29407 - (843) 556-8171 - www.gel.com Certificate of Analysis Company:

Connecticut Yankee Atomic Power Address:

362 Injun Hollow Rd East Hampton, Connecticut 06424

Contact:

Mr. Jack McCarthy Project:

Soils PO#.002332 Report Date: October 4, 2006 Client Sample ID.:

Sample ID:

Matrix:'.

  • Collect Date:

Receive Date:

Collector:

Moisture:

9530-0001-01 IF 172114003 TS 12-SEP-06 20-SEP-06 Client 11.2%

Project:

Client ID:

Vol. Recv.:

.YANK01204 YANK001 Parameter Qualifier Result Uncertainty LC TPU MDA Units DF Analyst Date Time Batch. Wt Rad Gamma Spec Analysis Gammiia,Solid-FSS GAM & ALL FSS 226 Ingrowth Waived:

Actinium:-228

-0.816 U -0.0t65 0.561 0.596 U

0.0341 0.106 U

0.0186 U -0.0191 U 0.00749 U

0.0765 0.826 0.717 U 0.00106 U

0.0268 13.1 0.596 U -0.00573 0.259

+/10..157

+/-0.0808

.:+/-0.285

+/-0.0795

+/-0.0241

+/-0.0332

.+/-0.019

+/-0.0484

+/-0.0603

+/-0.0734

+/-0.0624

+/-0.0882

+/-0.0198

+/-0.0248

+/-0.809

+/-0.0795

+/-0.0161

+/-0.0534 0.0536 0.0626 0.109 0.0286 0.0202

.0.0155 0.0171 0.0406 0.0501 0.0456 0.0286 0.0295 0.0169 0.0157 0.110 0.0286 0.0133 0.0162

+/-1+0.157

+/-0.0808

  • +/-0.285

+/-0.0795

+/-0.0241

+/-0.0332

+/-0.019

+/-0.0484

+/-0.0603

+/-0.0734

+/-0.0624

+/-0.0882

+/-0.0198

+/-0.0248

+/-0.809

+/-0.0795

+/-0.0161

+/-0.0534

  • 0.11.5 0,129 0.234 0.0604 0.0426 0.033 0.037 0.0851 0.108 0.0946 0.0591 0.0618 0.0358 0.0332 0.249 0.0604 0.0281 0.0341 pCi/g1 pCi/g pCi/g pc/ga pCi/ga pCi/gý pCi/g0 pCi/g.

pCi/ga pCilga pcdgý pCi/gý pCilka pCilga pCi/g pCil.G pCi/g pci/g MJHI 10/02/06 0545 574334 1

The following Prep Methods were performed Method Description Analyst Date Time Prep Batch Dry Soil Prep Dry Soil Prep GL-RAD-A-021 LXM2 09/20/06 1536 570843 The following Analytical Methods were performed Method Description I

EML HASL 300,4.5.2.3 Notes:

The Qualifiers in this report are defined as follows:

A quality control analyte recovery is outside of specified acceptance criteria Result is less than value reported 37

GENERAL ENGINEERING LABORATORIES, LLC 2040 Savage Road Charleston SC 29407 - (843) 556-8171 - www.gel.com Certificate of Analysis Company:

Connecticut Yankee Atomic Power Address:

362 Injun Hollow Rd East Hampton, Connecticut 06424 Report Date: October 4, 2006

Contact:

Mr. Jack McCarthy Project:

Soils PO# 002332 Client Sample ID:

9530-0001-01 IF Proiect:

YANKO 1204 Sample ID:

172114003, Client ID.

YANK001 Vol. Recv.:

Parameter QuaIifer Result U.n...ce.ta.,

TPU lvfA Units DF Analyst Date Time Batch Mt Result is greater than value reported A

The TIC is a suspected aldol-condensation product B

Target analyte was detected in the associated blank BD Results are either below the MDC or tracer recovery is low C

Analyte has been confirmed by GC/MS analysis.

D Results are reported from a diluted aliquot of the sample H

Analytical holding time was exceeded J

Value is estimated N/A: Spike recovery limits do not apply. Sample concentration exceeds spike concentration by 4X or more R

Sample results are rejected.

U Analyte was analyzed for, but not detected above the MDL, MDA, or LOD.

UI Gamma Spectroscopy-Uncertain identification X

Consult Case Narrative, Data Summary package, or Project Manager concerning this qualifier.

Y QC Samples were not spiked with this compound

^

RPD of sample and duplicate evaluated using +I-RL. Concentrations are <5X the RL h

Preparation or preservation holding time was exceeded The above sample is reported on a dry weight basis.

38

GENERAL ENGINEERING LABORATORIES, LLC 2040 Savage Road Charleston SC 29407 - (843) 556-8171 - www.gel.com Certificate of Analysis Company Connecticut Yankee Atomic Power Address 362 Injun. Hollow Rd East Hampton, Connecticut 06424

Contact:

Mr. Jack McCarthy, Project::

Soils PO# 002332 Report Date: October 4,2006 Client Sample ID:

Sample ID:.

Matrix:

Collect Date:

Receive Date:

Collector:

Moisture:

9530-0001-012F

.17211.4004 TS 12-SEP-06 20-SEP-06 Client 14.7%

Project:

Client ID:.

Vol. Recv.:

YANKO 1204 YANK001 Parameter Qualifier Result Uncertainty LC TPU MDA Units DF Analyst Date Time Batch Mt, Rad Gamma Spec Analysis GamnmaSolid-FSS GAM & ALL FSS 226 Ingrowth Waived Actinium-228

-0.308 0.617 0.567 U

0.0476 0.085 U

0.00907 U. -0.108 U -0.0462 U

0.00678

.0.841

  • 0.603 U

0.0123 U

-0.0179 13.2 0.567 U

-0.0113 0.280

+/-0.182

+1-0.126

.+1-0.267

+/-0.117

+/-0.0403

+/-0.0526

" +/-0.0268

+/-0.0688

+/-0.0829

+/-0.0727

+/-0.0715

+/-0.0938

+/-0.026

+/-0.0268

+/-1.05

+/-0.117

+/-0.0237

+/-0.0515 0.0648 0.0856 0 151 0.0376 0.0263 0.0245 0.0227 0.0511 0.0521 0.062

.0.0325 0.0388 0.0225 0.0182 0.184 0.0376 0.0186 0.0206

+/'0. 182

+/-0.126

+/-0;267

+/-0.117

+/-0.0403

+/-0.0526

+/-0.0268.

+/-0.0688

+/-0.0829

+/-0.0727.

+/-0.0715

+/-0.0938

+/-0.026

+/-0.0268

+/-1.05

+/-0.117

+/-0.0237

+/-0.0515 0.140 00A76 0.322 0.0796 0.0557 0.05 15 0.0495

.0.107 0.116 0.128 0.0672 0.0811i 0.0478 0.0387 0.409 0.0796 0.0391 0.0435 pCi/ag pci/g.

pCi/g 0041 pCi/g p04g pCi/g pCi/g pCi/ga pCi/g(

pCiig-pCi/g pCi/g0 pCi/ga pci/g pCi/ga pCi/gý MJH I 10/02/060649 574334 I

The following Prep Methods were performed Method Description Analyst Date Time Prep Batch Dry Soil Prep Dry Soil Prep GL-RAD-A-021 LXM2 09/20/06 1536 570843 The following Analytical Methods were performed Method Description I

EML HASL 300,4.5.2.3 Notes:

The Qualifiers in this report are defined as follows:

A quality control analyte recovery is outside of specified acceptance criteria Result is less than value reported 39

GENERAL ENGINEERING LABORATORIES, LLC 2040 Savage Road Charleston SC 29407 - (843) 556-8171 - www.gel.com Certificate of Analysis Company:

Connecticut Yankee Atomic Power Address:

362 Injun Hollow Rd East Hampton, Connecticut 06424 Report Date: October 4, 2006

Contact:

Mr. Jack McCarthy Project:

Soils PO# 002332 Client Sample ID:

9530-0001-012F Project:

YANKO 1204 Sample ID:

172114004 Client ID:

YANKOO I Vol. Recv.:

I a..a.....

vua,,u.fie Result Uncertainty LC TFU INDA Units DF Analyst Date Time Batch Mt, Result is greater than value reported A

The TIC is a suspected aldol-condensation product B

Target'analyte was detected in the associated blank..

BD Results are either below the MDC or tracer recovery is low C:, Analyte has been confirmed by GC/IIlS analysis.

D Results are reported from a diluted aliquot of the sample H

Analytical holding time was exceeded J

Value is estimated N/A Spike recovery, limits do not apply. Sample concentration exceeds spike concentration by 4X or more R

Sample results are rejected U

Analyte was analyzed for, but not detected above the MDL, MDA, or LOD.

UI Gamma Spectroscopy--Uncertain identification X

Consult Case Narrative, Data Summary package, or Project Manager concerning this qualifier

  • Y QC Samples were not spiked with this compound A

RPD of sample and duplicate evaluated using +/-RL. Concentrations are <5X the RL h

Preparation or preservation holding time was exceeded The above sample is reported on a dry weight basis.

40

GENERAL ENGINEERING LABORATORIES, LLC 2040 Savage Road Charleston SC 29407 - (843) 556-8171 - www.gel.com Certificate of Analysis Company:

Connecticut Yankee Atomic Power Address:

362 InjUn Hollow Rd East Hampton, Connecticut 06424

Contact:

Mr. Jack McCarthy

.Project:

Soils PO# 002332 Report Date: October 4, 2006

.Client.Sample ID:

Sample ID:

Matrix:

Collect Date:

Receive Date:

Collector:

Moisture:

9530-0001-016F 172114005 "TS 12-SEP-06 20-SEP-06 Client 12.9%

Proiect*

Client ID:

Vol. Recv.:

YANKO 1204 YANKOO L.

Parameter Qualifier Result Uncertainty LC.

TPU NIDA Units DF Analyst Date Time Batch Mt, Rad Gamma Spec Analysis

.Gamma, Solid-FSS GAM & ALL FSS.226 hlgrowth.

Waived Actinium-228 0.839

+/-0.188 Americium-241.

U 0.0204

+/-0.0268:

Bismuth-212

-UI 0.00

+/"0.472 Bismuth-214 0.588

+/-0.106 Cesium-134 U

0.0533

+/-0.0306 Cesium-137 0.0961

+/-0.0563

.Cobalt-60 U 0.00495

+/2-0.0235 Europium-152 U -0.00205

+/-0.0566 Europium-154 U -0.0049

+/-0.0823 Europium-155 U

0.0338

+/-0.0444 Lead-212 0.808

+/-0.0642 Lead-214 0.539

+/-0.0909 Manganese-54 U -0.00139

+/-0.023 Niobium-94 U -0.0112

+/-0.0237 Potassium-40 11.8

+/-1.02 Radium-226 0.588

+/-0.106 Silver-108m U 0.00216

+/-0.0185 Thallium-208 0.276

+/-0.0541 0.0649 0.0234 0.148 0.0347 0.0266 0.0226 0.0201 0.0466 0.0681 0.0411 0.0262 0.0347 0.0188 0.019 0.184 0.0347 0.0162 0.0174

+/-0.188

+/-0.0268

+/-0.472

+/-0.106

+/-0.0306

+/-0.0563,

  • +/-0.0235

+/-0.0566

+/-0.0823

+1-0.0444

+/-0.0642

+!-0.0909

+/-0.023

+/-0.0237

+/-1.02

+/-0.106

+/-0.0185

+1-0.0541

.-0.142.

-0.0484

  • 0.320 0.0744 0.0566 0.0481 0.0448 0.0983 0.149 0.0854 0.0546 0.0731 0.0407 0.0406 0.414 0.0744 0.0345 0.0375 pCi/g.

pCi/g pCi/g pCilg pCi/g pCi/g pCi/g pCi/ga pCi/ga pCi/g, pCi/g0 pCi/gU pCi/g9 pCi/gC pCi/gC pCil/a pCi/g0 pCi/.G MJHI 110/02/06 0650 574334 1

The following Prep Methods were performed Method Description Analyst Date Time Prep Batch Dry Soil Prep Dry Soil Prep GL-RAD-A-021 LXM2 09P20/06 1536 570843 The following Analytical Methods were performed Method Description EML HASL 300,4.5.2.3 Notes:

The Qualifiers in this report are defined as follows:

A quality control analyte recovery is outside of specified acceptance criteria Result is less than value reported 41

GENERAL ENGINEERING LABORATORIES, LLC 2040 Savage Road Charleston SC 29407 - (843) 556-8171 - www.gel.com Certificate of Analysis Company Connecticut Yankee Atomic Power Address:

362 Injun Hollow Rd.

East Hampton, Connecticut 06424 Report Date: October 4, 2.006

Contact:

Mr. Jack McCarthy Project:

Soils PO# 002332.

Client Sample ID:

9530-0001-016F Project:

YANK01204 SaimpleID."

172114005 Client ID:

YANK001 Vol. Recv.:

Paraueter Qualifier Result Uncertainty LC TPU MDA Units DF Analyst Date Time Batch Mt Result is greater than value reported,

.A The TIC is a suspected aldo!-condensation product B

Target analyte was detected in the associated blank.

3BD, Results are either below the MDC or tracer recovery is low C.

Analyte has been confirmed by GC/MS analysis D

Results are reported from a diluted aliquot of the sample H

Analytical holding time was exceeded J

Value is estimated N/A Spike recovery limits do not apply. Sample concentration exceeds spike concentration by 4X or more R.

Sample results are rejected U

Analyte was analyzed for, but not, detected above the MIDL, MDA, or LOD.

UT Gamma Spectroscopy-Uncertain identification X

ConstultCase Narrative, Data Summary package, or Project Manager concerning this qtualifier Y:

QC Samples were not spiked with this compound

^

RPD of sample and duplicate evaluated using +/-RL. Concentrations are <5X the RL h

Preparation or preservation holding time was exceeded The above sample is reported on a dry weight basis.

42

GENERAL ENGINEERING LABORATORIES, LLC 2040 Savage Road Charleston SC 29407 - (843) 556-8171 - www.gel.com Certificate of Analysis Company : Connecticut Yankee Atomic Power Address:

362 Injun Hollow Rd East Hampton, Connecticut 06424

Contact:

Mr. Jack McCarthy Project:

Soils PO# 002332 Report Date: October 4. 2006 Client Sample ID:

Sample ID:

Matrix:

Collect Date:

Receive Date:

Collector:

Moisture:

9530-0001-017F.

172114006 TS 12-SEP-06 20-SEP-06 Client 14.2%

Project:

Client ID:

Vol. Recv.:

YANKO 1204 YANK0 t Parameter Qualifier Result Uncertainty LC TPU MDA Units DF Analyst Date Time Batch Mt Rad Gamma Spec Analysis GaonmaSolid-FSS GAM & ALL FSS 226 Ingrowth Waivedý Actinium-228 0.828 Americium-241 U

-0.0107 Bismuth-212 0.881 Bismuth-214 0.612 Cesium-134 UI 0.00 Cesium-137 0.182 Cobalt-60 U -0.00988 Europium-152 U

0.0683 Europium-154 U

0.104 Europium-155 U

0.0308 Lead-212 0.882

+/-0.191 1/-0.0746 4/-0.459

+1-0.130

+/-0.0376

+/-0.0483

+/-0.0263

+/-0.0624 k/-0.0885

/-0.0643

+/-0.0991

+/-0.131 k/-0.0265

+/-0.0215

+/-1.37

+/-0.130

-/-0.0202 4/-0.0618 0.0683 0.0601 0.126 0.0327 0.028 0.021 0.0211 0.055 0.0671 0.0522 0.0264 0.0339 0.022 0.0199 0.229 0.0327 0.0156 0.022

+/-0.191

+/-0.0746

+1-0.459

+/-0.130

+/-0.0376

+1-0.0483

+/-0.0263

+/-0.0624

+/-0.0885

+/-0.0643

+/-0.0991

+/-0.131

+/-0.0265

+1-0.0215

+/-1.37

+/-0.130

+/-0.0202

+/-0.0618 0.149 0.125 0.276 0.0707 0.0597 0.0451 0.047.1 0.116 0.148 0.109 0.0555 0.0721 0.0474 0.0426 0.507 0.0707 0.0335 0.0469 pci/g pCi/g pCilg pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCilg pci/g pCi/g pC.g pCi/g MJH 1 10/02/060650 574334 Lead-214 Manganese-54 Niobium-94 Potassium-40 Radium-226 Silver-108m Thallium-208 0.857 U 0.000152 U

0.0279 13.3 0.612 U -0.00885 0.282

-l

-I The following Prep Methods were performed Method Description Analyst Date Time Prep Batch Dry Soil Prep Dry Soil Prep GL-RAD-A-021 LXM2 09/20/06 1536 570843 The following Analytical Methods were performed Method Description I

EML HASL 300, 4.5.2.3 Notes:

The Qualifiers in this report are defined as follows:

A quality control analyte recovery is outside of specified acceptance criteria Result is less than value reported 43

GENERAL ENGINEERING LABORATORIES, LLC 2040 Savage Road Charleston SC 29407 - (843) 556-8171 - www.gel~com Certificate of Analysis Company:

Connecticut Yankee Atomic Power Address:

362 lnjun Hollow Rd East Hampton, Connecticut 06424 Report Date: October 4, 2006

Contact:

Mr. Jack McCarthy Project:

Soils PO# 002332 Client Sample ID:

9530-0001-017F Proiect:

YANK01204 Sample ID:

172114006 ClientID:

YANK00I Vol. Recv.:

Parameter Qualifler Result Uncertainty LC TPU MDA Units DF Analyst Date Time Batch Mt Restlt is greater than value reported A

The TIC is a stspected aldol-condensation product B

Target analyte was detected in the associated blank BD Results are either below the MIDC or tracer recovery is low C

Analyte has been confirmed by GC/MS analysis Di Results are reported from a diluted aliquot of the sample H

Analytical holding time was exceeded J

Value is estimated N/A Spike recovery limits do not apply. Sample concentration exceeds spike concentration by 4X or more R.

Sample results are rejected U

Analyte was analyzed for, but not detected above the MDL, MDA, or LOD.

UI Gamma Spectroscopy--Uncertain identification X

Consu.lt Case Narrative, Data Summary package, or Project Managerconcerning this qualifier Y.

QC Samples were not spiked with this compound A

RPD of sample and duplicate evaluated using +/-RL. Concentrations are <5X the RL h

Preparation or preservation holding time was exceeded The above sample is reported on a dry weight basis.

44

GENERAL ENGINEERING LABORATORIES, LLC 2040 Savage Road Charleston SC 29407 - (843) 556-8171 - www.gel.com Certificate of Analysis Company:, Connecticut Yankee Atomic Power Address 362 Injun HollowRd East Hampton. Connecticut 06424

Contact:

Mr. Jack McCarthy.

Project:

Soils PO# 002332 Report Date: October 4, 2006 Client Sample ID:

Sample. ID:

Matrix:.

Collect Date:

Receive Date:

Collector:

Moisture:

9530-0001-018F 172114007 TS 08-SEP-06 20-SEP-06 Client 14.8%

Project:

Client ID:

Vol. Recv.:.

YANKO 1204 YANK001 Parameter Qualifier Result Uncertainty LC TPU MDA Units DF Analyst Date Time Batch Mt Rad Gamma Spec Analysis Gainina,Solid-FSS GAM & ALL FSS 226 Ingrowth Waived Actinium-228 0.945

+/-0.238 Americium-241 U

0.0923 4/-0.096 Bismuth-212 0.675

+/-0.431 Biismuth-214 0.732

+/-0.138 Cesium-134 U

0.0349

+/-0.0373 Cesium-137 0.167

+/-0.0399 Cobalt-60 U -0.00764

+/-0.0307 Europium-152 U -0.0133

+/-0.0753 Europium-154 U -0.00119

+/-0.0954 Europium-155 U

0.063.

+/-0.0773 Lead-212 0.991

+/-0.113 Lead-214 0.806

+/-0.124 Manganese-54 U

-0.0134

+/-0.0253 Niobium-94 U

-0.0159

+/-0.0516 Potassium-40 13.2

+/-1.34 Radium-226 0.732

+/-0.138 Silver-108m U

0.0122

+/-0.0263 Thallium-208 0.272

+/-0.0551 0.0832 0.0737 0.165 0.0413 0.0288 0.0254 0.0244 0.0589 0.0784 0.0658 0.0356

  • 0.042 0.0203 0.0222 0.214 0.0413 0.0225 0.023

+/-0.238

+/-0.096

+/-0.431

+1-0.138

+/-0.0373

+/-0.0399

.+/-0.0307

+/-0.0753

+/-0.0954

+/-0.0773

+/-0.i 13

+/-0.124

+/-0.0253

+/-0.0516

+/- 1.34

+/-0.138

+/-0.0263

+/-0.0551 0.166 0.147 0.330 0.0825 0.0575 0.0507

.0.0488 0.118 0.157 0.132 0.0712 0.084 0.0405 0.0443 0.428 0.0825 0.045 0.046 pCi/gC pCi/gý pCi/g pCi/g pCi/9 pCi/g-pu~g pCila pCi/g9 pCi/g pCi/g pCi/g pCWlg pQi/g PC i/ku pCi/.G pCi/g pCi/g MJHI 10/02/06 0659574334 The following Prep Methods were performed Method Description Analyst Date Time Prep Batch Dry Soil Prep Dry Soil Prep GL-RAD-A-021 LXM2 09/20/06 1536 570843 The following Analytical Methods were performed Method Description EML HASL 300,4.5.2.3 Notes:

The Qutalifiers in this report are defined as follows:

A quality control analyte recovery is outside of specified acceptance criteria Result is less than value reported 45

GENERAL ENGINEERING LABORATORIES, LLC 2040 Savage Road Charleston SC 29407 - (843) 556-8171 - www.gel.com Certificate of Analysis Company Connecticut Yankee Atomic Power Address:

362 Injun Hollow Rd East Hampton, Connecticut 06424 Report Date: October 4, 2006

Contact:

Mr. Jack McCarthy Project:

Soils.PO# 002332 Client Sample ID:

9530-0001-018F Project:

YANK01204 Sample.ID:

172114007

.Client ID:

YANKOOI Vol. Recv.:

P,.,reter t..Qualif,*r Result Uncertainty LC TPU MDA Units DF Analyst Date Time Batch Mt Result is greater than value reported A

The TIC is a suspected aldol-condensation. product B

Target analyte was detected in theassociated blank BD Results are either below the MDC or tracer recovery: is low C

Analyte has been confirmed by GCIMS analysis D-Results are reported from a diluted aliquot of the sample H

Analytical holding time was exceeded I

Value is estimated N/A Spike recovery limits do not apply. Sample concentration exceeds spike concentration by 4X or more R

Sample results are rejected U

Analyte was analyzed for, btut not detected above the MDL, MDA, or LOD.,

UI Gamma Spectroscopy-Uncertain identification X

Consult Case Narrative, Data Summary package,,or Project Manager concernino this qualifier.

Y* QC Samples were not spiked with this compound A

RPD of sample and duplicate evaluated using +/-RL. Concentrations are <5X the RL h

Preparation or preservation holding time was exceeded The above sample is reported on a dry weight basis.

46

GENERAL ENGINEERING LABORATORIES, LLC 2040 Savage Road Charleston SC 29407 - (843) 556-8171 - www.gel.com Certificate of Analysis Company:

Connecticut Yankee Atomic Power Address:

362 Injuri Hollow Rd East Hampton, Connecticut 06424

Contact:

Mr. Jack McCarthy Project:

Soils PO# 002332 Report Date: October 4, 2006 Client Sample ID:

Sample ID:

Matrix:

Collect Date:

Receive Date:

Collector:

Moisture:

9530-0001-001IF 172114008 TS 08-SEP-06 20-SEP-06 Client 12.9%

Proiect:

Client ID:

Vol. Recv.:

YANKO 1204 YANKOOI '

Parameter Qualifier. Result Uncertainty LC TPU

,IDA Units DF Analyst Date Time Batch. Mt Rad Gamma Spec Analysis Gam'oa,Solid-FSS GAM & ALL FSS 226 Ingrowth Waiwed Actinium-228 Americium-24l B ismuth-212 Bismuth-214 Cesium-134

.Cesium-137 Cobalt60.

Europium-152 Europium-I 54 Europium-155 Lead-2 12 Lead-214 Manganese-54 Niobium-94 Potassium-40 Radium-226 Silver-108m Thallium-208 0.738

.U

-0.015 0.645 0.502 U

0.0168 U

0.0131 U

0.0626 U

0.0345 U

0.0739 0*685 0.624 U

0.00591 U 0.000794 11.8 0.502 U

0.0163 0.217

+/-0;227

+/-0.104

+/-0.283

+/-0.108

+/-0.0257

+/--0.0406

+1-0.025

+/-0.0822

+/-0.0817

+/-0.0872

+/-0.0908

+/-0.109

+/-0.0242

+/-0.0233

+/-1.22

+/-0.108

+/-0.022

+/-0.0523 0.0713 0.0784 0.170 0.0376 0.0246 0.0215 0.0215 0.0536 0.0713 0.0598 0.0323 0.0365 0.0212 0.0194 0.190 0.0376 0.0196 0.0203

+/-0.227

  • +1-0.104

+/-0.283

+/-0.108

+/-0.0257

+/-0.0406

.+/-0.025

+/-0.0822

+1-0.0817

+/-0.0872

+/-0.0908

+/-0.109

+/-0.0242

+/-0.0233

+/-1.22

+/-0.108

+/-0.022

+/-0.0523 0.143 0.157' 0.340 0.0751 0.0492 0,0429 0.0429 0.107 0.143 0.120 0.0646 0.0729 0.0423 0.0388 0.379 0.0751 0.0392 0.0407

.pcilg pCi/g pCig pci/g pCi/g pCt/g pCi/g0 pci/..

pCi/g pCi/g pCi/g pCi/g pCi/g pci/g pCi/g pCi/g pCi/0g pCi/g MJHI 10/02/06.0700 574334.]

The following Prep Methods were performed Method Description Analyst Date Time Prep Batch Dry Soil Prep Dry Soil Prep GL-RAD-A-021 LXM2 09/20/06 1536 570843 The following Analytical Methods were performed Method Description EML HASL 300, 4.5.2.3 Notes:

The Qualifiers in this report are defined as follows A quality control analyte recovery is outside of specified acceptance criteria Result is less than value reported 47

GENERAL ENGINEERING LABORATORIES, LLC 2040 Savage Road Charleston SC 29407 - (843) 556-8171 - www.gel.com Certificate of Analysis Company:

Connecticut Yankee Atomic Power Address:

362 lnjun Hollow Rd East Hampton, Connecticut 06424 Report Date: October 4, 2006

Contact:

Mr. Jack McCarthy Project:

Soils PO# 002332 Client Sample ID:..

9530-0001-001F Proiect:

YANK01204 Sample ID:.

172114008 ClientID:.

YANKOO I Vol. Recv.:

Parameter Qualifier Result Uncertainty LC TPU MDA Units DF Analyst Date Time Batch Mt Result is greater than value reported A

The TIC is a suspected aldol-condensation product B

Targetanalyte was detected in the associated blank..

BD Results are either below the MDC.or tracer recovery is low C

Analyte has been confirmed by, GC/MS analysis D

Resultsare reported from a diluted aliquot of the sample H

Analytical holding time was exceeded J

Value is estimated N/A Spike, recovery limits do not apply. Sample concentration exceeds spike concentration by 4X or more R

Sample results are rejected U. Analyte was analyzed for, but not detected above the MDL, MDA, or LOD.

UT Gamma Spectroscopy-Uncertain identification X

Consult Case Narrative, Data Summary package, or Project Manager concerning this qualifier Y

QC Samples were not spiked with this compound A

RPD of sample and duplicate evaluated using +/-RL. Concentrations are <5X the RL h

Preparation or preservation holding time was exceeded The above sample is reported on a dry weight basis.

48

GENERAL ENGINEERING LABORATORIES, LLC 2040 Savage Road Charleston SC 29407 - (843) 556-8171 - www.gel.com Certificate of Analysis Company:

Connecticut Yankee Atomic Power Address:

362 Injun Hollow Rd East Hampton, Connecticut 06424

Contact:

Mr. Jack McCarthy Project:

Soils PO# 002332 Report Date: October 4, 2006 Client Sample ID:

Sample ID:

Matrix:

Collect Date:

Receive Date:

Collector:

Moisture:

9530-0001 -O02F 172114009 TS 08-SEP-06 20-SEP-06 Client 8.53%

Project:

Client ID:

Vol. Recv.:

YANKO 1204 YANK001 Parameter Qualifier Result Uncertainty LC TPU MDA Units DF Analyst Date Time Batch Mt Rad Gamma Spec Analysis Gamma.Solid-FSS GAM & ALL FSS 226 Ingrowth Waived Actinium-228 Americium-24 I Bismuth-212 Bismuth-214 Cesium-134 Cesium-137 Cobalt-60 Europium-152 Europium-154 Europium-155 Lead-212 Lead-214 Manganese-54 Niobium-94 Potassium-40 Radium-226 Silver-108m Thallium-208 0.696 U -0.00484, 0.561 0.653 U

0.00964 0.127 U

-0.0357 U

-0.0113.

U 0.0778 U

0.0536 0.696 0.578 U

-0.0312 U

-0.02P59 9.66 0.653 U

0.0283 0.277

+/-0.268

+/-0.0496

+/-0.449

+/-0.137

+/-0.0411

+1-0.0449

+/-0.0455

+/-0.0985

+/-0.218

+/-0.0919

+/-0.0999

+/-0.122

+/-0.0368

+/-0.0337

+/-1.29

+/-0.137

+/-0.0287

+/-0.0706 0.1*14 0.0407 0.204 0.0605 0.0364 0.0255 0.0329 0.069 0.112 0.0584 0.0395 0.0501 0.0284 0.0271 0.190 0.0605 0.0266 0.0276

+/:0.268

+/-0.0496

+/-0.449

+/-0.137

+/-0.0411

+/-0;0449

+/-0.0455

+/-0.0985

+/-0.218

+/-0.0919

+/-0.0999

+/-0.122

+/-0.0368

+/-0.0337

+1-1.29

+/-0.137

+/-0.0287

+/-0.0706 0.227 0.0813 0.407 0.121 0.0727 0.0509 0.0658 0.138 0.225 0.117 0.0789.

0.100 0,0567 0.0541 0.380 0.121 0.0531 0.0552 pCi/g pCi/g pCi/g pCi/g pci/gC pCilg' pci/g pCi/g pCi/g pCi/g pCi/g pCilg pCi/g pCi/,g pCi/g pCi/g pCi/g pCi/g pCi/g MJHI 10/02/06 0812 574334 The following Prep Methods were performed Method Description Analyst Date Time Prep Batch Dry Soil Prep Dry Soil Prep GL-RAD-A-021 LXM2 09/20/06 1536 570843 The following Analytical Methods were performed Method Description I

EML HASL 300,4.5.2.3 Notes:

The Qualifiers in this report are defined as follows:

A quality control analyte recovery is outside of specified acceptance criteria Result is less than value reported 49

GENERAL ENGINEERING LABORATORIES, LLC 2040 Savage Road Charleston SC 29407 - (843) 556-8171 - www.gel.com Certificate of Analysis Company Connecticut Yankee Atomic Power Address:

362 Injun Hollow Rd East Hampton, Connecticut 06424 Report Date: October 4, 2006

Contact:

Mr. Jack McCarthy Project:

Soils PO# 0023.32 Client Sample ID:

9530--0001--002F Project:

YANKO 1204 Sample D:.

172114009 Client ID:

YANKOOI Vol. Recv.:

Parameter Qualifier Result Uncertainiy LC.

Ift, MDA Units DF Analyst Date Time Batch Mt Result is greater than value reported A

The TIC is a suspected aldol-condensation product B

Target analyte was detected in the associated blank BD Results are either below the.MDC or tracer recovery is low C

Analyte has been confirmed by GC/MS analysis D

Results are reported from a diluted aliquot of the. sample H

Analytical holding time was exceeded J

Value is estimated N/A Spike recovery limits do not apply. Sample concentration exceeds spike concentration by 4X or more R

Sample results are rejected U

Analyte was analyzed for, but not detected above the MDL, MDA, or LOD.

UI Gamma Spectroscopy--Uncertain identification X

Consult Case Narrative, Data Summary package, or Project Manager concerning this qualifier Y

QC Samples were not spiked with this compotnd A

RPD of sample and duplicate evaluated using +/-RL. Concentrations are <5X the RL h

Preparation or preservation holding time was exceeded The above sample is reported on a dry weight basis.

50

GENERAL ENGINEERING LABORATORIES, LLC 2040 Savage Road Charleston SC 29407 - (843) 556-8171 - www.gel.com Certificate of Analysis Company Connecticut Yankee Atomic Power Address :

362 Injun Hollow Rd East Hampton, Connecticut 06424

Contact:

Mr. Jack McCarthy Project:

Soils PO# 002332 Report Date:

October 4, 2006 Client Sample ID:

Sample ID:

Matrix: :

Collect Date:

Receive Date:

Collector Moisture:

9530-0001 -003F 172114010 TS 08-SEP-06 20-SEP-06 Client 14.3%

' Project" Client ID:

Vol. Reckv.:

YANKO1204 YANKOO I Parameter.

Qualifier Result Uncertainty, LC, TPU MDA Units DF Analyst Date Time Batch Mt, Rad Alpha Spec Analysis Alphaspec Am241, Cm, Solid ALL FSS Americium-24 I U

Curium-242 U

..Curium-243/244.

U Alphaspec Pu, Solid-ALL FSS Plutonium-238 U

Plutonium-239/240 U

Liquid Scint Pu241, Solid-ALL FSS Plutonium-241 U

Rad Gamma Spec Analysis 0.0467 0.00

-0.0131

+/-0.0757

,+/-0.0582

+/-m0.0564 0.0244

.0.00 0.0346,

+1-0.0759

+/-0.0582

+/-0.0564 0.123 0.0804 0.143, 0.369 0.156

.17.6

-0.11

+/-0.141 0.148

+/-0.141 0.0343

+/-0.0774.

0.0416 +4-0.0775 0.294

+/-9.99 8.37

+/-9.99 Gamima, Solid-FSS GAM & ALL FSS 226 Ingrowth Waived Actinium-228 0.714

+1-0.158 Americium-241 U

-0.0786

+/-0.119 Bismuth-212 0.614

+/-0.320 Bismuth-214 0.576

+/-0.109 Cesium-134 U

0.0352

+/-0.0251 Cesium-137 0.259

+1-0.0505 Cobalt-60 U-0.000206

+/-0.0228 Europium-152 U

-0.021

+/-0.0606 Europium-154 U

0.00953

+/-0.0662 Europium-155 U

0.0328

+/-0.0592 Lead-212 0.849

+/-0.0694 Lead-214 0.582

+/-0.102 Manganese-54 U

0.00343

+/-0.0221 Niobium-94 U

0.012

+/-0.0206 Potassium-40 12.6

+/-0*952 Radium-226 0.576

+/-0.109 Silver-108m U

0.00762

+/-0.0187 Thallium-208 0.275

+/-0.0532 Rad Gas Flow Proportional Counting.

0.0691 0.0887 0.151 0.0354 0.0238 0.0182 0.0191 0.0493 0.0569 0.055 0.0292 0.0344 0.0186 0.0183 0.143 0.0354 0.017 0.0172

4-0.158

+/-0.119

+/-0.320

+/-0.109

+4-0.0251

+/-0.0505

+4-0.0228

+/-0.0606

+1-0.0662 4-0.0592

+/-0.0694

+1-0.102

+/-0.02221

+1-0.0206

+1-0.952 W/-0.109 4t--0.0187 4/-0.0532

  • 0.150 0.185 0.325 0.0757 0.0511 0.0392 0.0429 0.104 0.126 0.114 0.061 0.0727 0.0404 0.0391 0.334 0.0757 0.0361 0.0371 0.0129 pCi/ga pCi/ge pCi/ra pCi/g-pCi/g pCi/g-pCilg pCi/ga pCilg pCi/gC pCi/g pu~g pCt/g0 pCi/g0 pCi/ga pCilg.

pCi/ga pCilk pCilýg TCt 09/28/06 1156 572120 I

TCI 09/28/06 0935 572121 2

TCI 09/29/062214 572122. 2 MJHI 10/02/06 0918 574334 4

GFPC, Sr9O, solid-ALL FSS Strontium-90 Rad Liquid Scintillation Analysis U

0.00833

+/-0.00781 0.00603 +--0.00781 KSDI 09/29/06 2335 571177 DFAI 09/25/06 0226 570933 5

LSC, Tritium Dist, Solid-HTD2,ALL FSS Tritium U

-1.52

+1-6.64 5.67

+1-6.64 12.1 pCi/g 51

GENERAL ENGINEERING LABORATORIES, LLC 2040 Savage Road Charleston SC 29407 - (843) 556-8171 - www.gel.com Certificate of Analysis Company:. Connecticut Yankee Atomic Power Address:

362 Injun Hollow Rd East Hampton, Connecticut 06424

Contact:

Mr. Jack McCarthy Project:

Soils PO# 002332 Report Date: October 4, 200.6 Project:

YANK01204 Client ID:.* YANK001 Vol. Recv.:

Client Sample ID:

Sample ID:

9530-0001-003F 172114010:*

Pararneter Qualifier Result Rad Liquid Scintillation Analysis Liquid Scint C14, Solid AIIFSS Carbon-14 U

0.00 Liquid Scint Fe55, Solid-ALL FSS iron-55 U

12.2 Liquid ScintNi63, SolidýALL FSS Nickel-63 U

-5.95 Liquid Scint Tc99. Solid-ALL FSS Technetiumn-99 U -0.0782 Uncertainty LC TPU MDA Units DF Analyst Date Time Batch Nil

+/-0.0813 0.0682 +/ý0.0813 0.145

+/-25.2 17.2

+/-25.2 36.0

+/-10:8 9134

+/-10.8:

19.6

+/-4.274.

0.232

+/-0.274 0.478 pCi/g pCig

/

pCi/.c pC ilg AXD2 09/23/06 1509 570934 MXPI 09/27/06 1330 570929 MXPI. 09/25/06 1634 570930 KXRI 09/29/06 1634 570932 1 The following Prep Methods were performed Method Description Analyst.

Date Time Prep Batch Dry Soil Prep Dry Soil Prep GL-RAD-A-021 LXM2 09/20/06 1536 570843 The following Analytical Methods were performed Method Description I

DOE EML HASL-300, Am-05-RC Modified 2

DOE EML HASL-300, Pu-I I-RC Modified 3

DOE EML HASL-300. Pu-I I-RC Modified 4

EML HASL 300,4.5.2.3 5

EPA 905.0 Modified 6

EPA 906.0 Modified 7

EPA EERF C-01 Modified 8

DOE RESL Fe-1, Modified 9

DOE RESL Ni-1, Modified 10 DOE EML HASL-300, Tc-02-RC Modified 1I DOE EML HASL-300,. Tc-02-RC Modified Surrogate/Tracer recovery Test Recovery%

Acceptable Limits Americium-243 Plutonium-242 Carrier/Tracer Recovery Carrier/Tracer Recovery Carrier/Tracer Recovery Carrier/Tracer Recovery Alphaspec Am241, Cm, Solid ALL Alphaspec Pu, Solid-ALL FSS Liquid Scint Pu241, Solid-ALL FS GFPC, SOO, solid-ALL FSS Liquid Scint Fe55, Solid-ALL FS Liquid Scint Ni63, Solid-ALL FS 96 87 84 79 70 74 (15%-125%)

(15%-125%)

(25%-125%)

(25%-125%)

(15%-125%)

(25%-125%)

52

GENERAL ENGINEERING LABORATORIES, LLC 2040 Savage Road Charleston SC 29407 - (843) 556-8171 - www.gel.corn Certificate of Analysis Company:

Connecticut Yankee Atomic Power

-Address:

362 Injun Hollow Rd East Hampton, Connecticut 06424 Report Date: October 4, 2006

Contact:

Mr. Jack McCarthy Project:

Soils PO# 002332 Client Sample ID:

-9530-0001-003F Project:

YANKO 1204.

Samlple ID:

172114010 ClientilD:

YANK00 I Vol. Recv.:.

Parameter Qualifier Result Uncertainty LC TPU MDA Units DF Analyst Date Time Batch Mt Carrier/Tracer Recovery Liquid Scint Tc99, Solid-ALL FS 76 (15%-125%)

Notes:

The Qualifiers in this report are defined as follows:

A quality control analyte recovery is outside of specified acceptance criteria:

Result is less than value reported Result is greater than value reported A. The TIC.is a suspected aldol-condensation product B

Target analyte was detected in the associated blank BD Results are either below the MDC or tracer recovery is low C

Analytehas been confirmed by GC/MS analysis D

Results are reported from a diluted aliquot of the sample H

Analytical holding time was exceeded J

Value is estimated

,.N/A Spike recovery limits do not apply. Sample concentration exceeds spike concentration by 4X or more R

Sample results are rejected U

Analyte was analyzed for, but not detected above the MDL, IvIIDA, or LOD.

UI Gamma Spectroscopy-Uncertain identification X

Consult Case Narrative, Data Summary package, or Project Manager concerning this qualifier Y

QC Samples were not spiked with this compound A

RPD of sample and duplicate evaluated using +/-RL. Concentrations are <5X the RL h

Preparation or preservation holding time was exceeded The above sample is reported on a dry weight basis.

53

GENERAL ENGINEERING LABORATORIES, LLC 2040 Savage Road Charleston SC 29407 - (843) 556-8171 - www.gel.com Certificate of Analysis Company:

Connecticut Yankee Atomic Power Address::

362 Injun Hollow Rd East Hampton, Connecticut 06424

Contact:

Mr. Jack McCarthy Project:

Soils PO# 002332 Report Date: October 4, 2006 Client Sample iD':

9530-0001-004F Proiect:

..YANK01204 Sample ID:.,

172114011 ClientTD:

YANK001 Matrix:

TS Vol. Recv.:

Collect Date:

08-SEP-06 Receive Date:

20-SEP-06 Collector:

Client Moisture:

15;5%

Parameter Qualifier Result Uncertainty LC TPU.

MDA Units DF Analyst Date Time Batch Mt Rad Gamma Spec Analysis

.Ganuma, Solid-FSS GAM & ALL FSS 226 higrowth Waived Actinium-22:

1.02

.+/-0.178 Americium 241 U 0-000195

+1-0.036 Bismuth-212 0.578

+/-0.394 Bismuth-214 0.622

+/-0.121 Cesium-134 U.

0.0251

.+/-0.0353 Cesium-137 0.131

+/-0.0653 Cobalt-60 U

0.0147

+/-0.0291 Europium-152 U

-0.0169

+/-0.0581 Europium-154 U.0.00939

+/-0.0825 Europium-155 U

0.0221

+1-0.0577

'Lead-212 0.985

+/-0.0757 Lead-214 0.689

+/-0.108 Manganese-54 U

0.0214

+/-0.0294 Niobium-94 U -0.00774

+/-0.0236 Potassium-40 14.8

+/-1.12 Radium-226 0.622

+/-0.121 Silver-108m U -0.0104

+/-0.0227 Thallium-208 0.264

+/-0.0635

.0.0716 0.0292 0.171 0.0425 0.0279 0.0215 0.026 0.0504 0.0707 0.0515 0.0308 0.0375 0.0259 0.0193 0.186 0.0425 0.0191 0.0208

  • +/-0.178

+/-0.036

+/-0.394

+/-0.121

+/-0.0353

+/-0.0653

+/-0.0291

+/-0.0581

.+/-0.0825

+/-0.0577

+/-0.0757

+/-0.108

+/-0.0294

+/-0.0236

+/-1.12

+/-0.121

+/-0.0227

+/-0.0635

%.0.156 0.0602 0.366 0.0903 0.0596 0.0462 0.057 0.106 0.155 0.107 0.0642 0.079 0.0553 0.0414 0.421 0.0903 0.0405 0.0446

  • pCi/g pCilg p Ci/ga pCi/i pCi/g0 pCilga pCi/g0 pCi/g pci/g-pCilg0 pCi/gU pCilgC pci/g_

pCi/gU MJHI 10/02/06.091.9.574334-.

1.

The following Prep Methods were performed Method Description Analyst Date Time Prep Batch Dry Soil Prep Dry Soil Prep GL-RAD-A-021 LXM2 09/2t0/06 1536 570843 The following Analytical Methods were performed Method Description I

EML HASL 300,4.5.2.3 Notes:

The Qualifiers in this report are defined as follows:

A quality control analyte recovery is outside of specified acceptance criteria Result is less than value reported 54

GENERAL ENGINEERING LABORATORIES, LLC 2040 Savage Road Charleston SC 29407 - (843) 556-8171 - www.gel.com Certificate of Analysis Company:

Connecticut Yankee Atomic Power, Address:

362 Injun Hollow Rd East Hampton, Connecticut 06424 Report Date: October 4, 2006

Contact:

Mr. Jack McCarthy Project:

Soils PO#.002332 Client Sample ID:,

9530-0001-004F Proiect:

YANK01204 SamplelD:

172114011 ClientID:

YANKOO I Vol. Recv.:

Parameter Qualifier Result Uncertainty LC TPU MDA Units DF Analyst Date Time Batch Nit Result is greater than value reported A

The TIC is a suspected aldol--condensation product B

Target analyte was detected in the associated blank BD Results are either below the MDC or tracer recovery is0low C

Analyte has been confirmed by: GC/MS analysis-D Results are reported froma diluted aliquot of the sample H

Analytical holding time was exceeded J

Value is estimated N/A Spike recovery limits do not apply. Sample concentration exceeds spike concentration by 4X or more R

Sample results are rejected U

Analyte was analyzed for, but not detected above the MDL, MDA, or LOD.

UI Gamma Spectroscopy--Uncertain identification X

Consult Case Narrative, Data Summary package, or Project Manager concerning this qualifier Y

QC Samples were not spiked with this compound A

RPD of sample and duplicate evaluated using +/-RL. Concentrations are <5X the RL h

Preparation or preservation holding time was exceeded The above sample is reported on a dry weight basis.

55

GENERAL ENGINEERING LABORATORIES, LLC 2040 Savage Road Charleston SC 29407 - (843) 556-8171 - www.gel.corn Certificate of Analysis Company :

Connecticut Yankee Atomic Power.

Address :

362 lnjun Hollow Rd

Contact:

Project:

East Hampton, Connecticut 06424 Mr. Jack McCarthy Soils PO# 002332:

Report Date: October 4. 2006 Client Sample ID:

Sample ID:

Matrix:

Collect Date:

Receive Date:

Collector:

Moisture:

9530-0001 -005F 172114012-TS 08-SEP-06 20-SEP-06 Client 7.95%

Proiect:

Client ID:.

Vol. Recv.:

YANK01204 YANKO01 Parameter Qualifier Result Uncertainty LC TPU MDA Units DF Analyst Date Time Batch Ml Rad Gamma Spec Analysis GamrnaSolid-7FSS GAM & ALL FSS 226 higrowth Waived Actinium-2281 0.486

+1-0.139 0.0523

+/-0.139 0.114 pCi/g MJHI 10/02/06 0919 574334

.Americiuim-241 U -0.0773

+/=-0.0839 0.0672 +/-0.0839 0.139 pCi/g Bismuth-212 0.380

+/-0.185 0.125

+/-0.185 0.268 pCi/g B ismuth-214 0.475

+/-0.0791 0.0275 +/-0.0791 0.0589 pCi/g Cesium-134 UI 0.00

+/-0.0296 0.021 +/-0.0296 0.0446 pCi/g Cesium-137 0.0485

+/-0.024 0.0172

+/-0.024 0.0367 pCi/g Cobalt-60 U ý-0.0011

+/-0.0185.

0.0154 +/-0.0185 0.0343 pCi/g Europium-152 U --. 0439

+/-0.0462 0.039 +/-0.0462 0.0824 pCi/g EuropiLIm-154 U 0.00551

+/-0.0535 0.0457 +/-0.0535 0.101 pCi/g Europium-t55 U

0.0377

+/-0.0494 0.0463 +/-0.0494 0.096 pCi/g Lead-212 0.626

+/-0.0591 0.023 +/-0.0591 0.0481 pCi/g Lead-214 0.462

+/-0.0792 0.0295 +/-0.0792 0.0622 pCi/g Manganese-54 U -0_0(439

+/-0.0218 0.0163 +/-0.0218 0.035 pCi/g Niobium-94 U -0.00642

+/-0.0165 0.0134 +/-0.0165 0.0289 pCi/g Potassium-40 11.2

+/-0.824 0.153

+/-0.824 0.341 pCi/g Radium-226 0.475

+/-0.0791 0.0275 +/-0.0791 0.0589 pCi/g Silver-108m U -0.00535

+/-0.0152 0.013 +/-0.0152 0.0278 pCi/g Thallium-208 0.225

+/-0.042 0.0121

+/-0.042 0.0262 pCi/g The following Prep Methods were perforned Method Description Analyst Date Time Prep Batch Dry Soil Prep Dry Soil Prep GL-RAD--A-021 LXM2 09/20/06 1536 570843 The following Analytical Methods wert performed Method Description EML HASL 300, 4.52-3 Notes:

The Qualifiers in this report are defined as follows:

  • ¢ A quality control analyte recovery is outside of specified acceptance criteria Result is less than value reported 56

GENERAL ENGINEERING LABORATORIES, LLC 2040 Savage Road Charleston SC 29407 - (843) 556-8171 - www gel.com Certificate of Analysis Company:

Connecticut Yankee Atomic Power Address 362 Injun Hollow Rd East Hampton, Connecticut 06424 Report Date:

October 4, 2006

Contact:

Mr. Jack McCarthy Project:,

Soils.PO# 002332.

Client SamplelD:.

.9530-0001-005F Proiect:

YANKO 1204 Sample ID:

172114012 Client lID:

YANKKOO Vol. Recv.:.

Pai'ajete,"

Qualifier Result Uncertainty LC TPU MDA Units DF Analyst Date Time Batch Mt, Result is greater thanvalue reported A

The TIC is a suspected aldol-condensation product.

B Target analyte was detected in the associated blank:

BD Result is are either below the MDC or tracer recovery is low.

C, Analyte has been confirmed by GC/MS analysis D

Results are reported from A diluted aliquot of the sample H

Analytical holding time was exceeded J

Value is estimated N/A Spike recovery limits do not apply. Sample concentration:exceeds spike concentration by 4X or more R

Sample results are rejected.

U Analyte was analyzed for, but not detected above the MDL, MDA, or LOD.

UI Gamma Spectroscopy-Uncertain identification X

Consult Case Narrative, Data Summary package, or Project Manager concerning this qualifier Y.

QC Samples were not spiked with this compound A

RPD of sample and duplicate evaluated using +/-RL. Concentrations are <5X the RL h

Preparation or preservation holding time was exceeded The above sample is reported on a dry weight basis.

57

GENERAL ENGINEERING LABORATORIES, LLC 2040 Savage Road Charleston SC 29407 - (843) 556-8171 - www.gel.com Certificate of Analysis Company :

Connecticut Yankee Atomic Power Address:

362 Injun Hollow Rd East Hampton, Connecticut 06424

Contact:

Mr. Jack McCarthy Project:

Soils PO# 002332 Report Date: October 4. 2006 Client Sample ID:

Sample ID:

Matrix:

Collect Date:

Receive Date:

Collector:

Moisture:

9530-0001-006F 172114013 TS 08-SEP-06.

20-SEP-06 Client 11.7%

Proiect:

Client ID:

Vol Recv.:

YANKO 1204

'YANK00 II" Parameter Qualifier Result Uncertainty LC TPU MIDA Units DF Analyst Date Time Batch Mt Rad Gamma Spec Analysis GammaSolid-FSS GAM &ALL FSS 226 Ingrowth Waived' Actinium-228 0.680

+/-0.162 0.0598

+/-0.162 0.1:29 pCi/g MJHI 10/02/06 0920 574334 Americium-241 U

,0.014

+/-0.0793 0.0622 +/-0.0793 0.128

.pCi/-

Bismuth-212 0.558

+/-0.261 0.139

+/-0.261 0.298 pCi/g Bismnuth-2l4 0.573

'+/-0.0981 0.0327 +/-0.0981 0.0696 pCi/g CesiuIm-134 UI 0.00

+/-0.0311 0.0234 +/-0.0311 0.0496 pCi/g Cesium-137 0.121

+/-0.0276 0.0199: +/-0.0276 0.0423.:

pCilg Cobalt-60

U 0.00766

+/-0.0243 0.0187. +/-0.0243 0.0413.

pCi/g Europium-152 U

0.0263.

+/-0.0669 0.0524 +/-0.0669 0.109 pCi/g.

Europium-154 U -0.00581

-/-0.0716 0.0516 +/-0.0716 0.114 pCi/g EuropiIm7-155 U

0.00914

+/-0.0614 0.0537 +/-0.0614*

0.111 pCi/g Lead-212 0.803

+/-0.0853 0.0278 +/-0.0853 0.0578 pCi/g Lead-214 0.584

+/-0.120 0.0342

+/-0.120 0.0718 pCi/g Manganese-54 UI 0.00

+/-0.0294 0.0184 +/-0.0294 0.0394 pCiig Niobium-94 U

-0.0003

+/-0.0202 0.017 +/-0.0202 0.0362 pCi/g Potassiuim-40 12.7

+/-1.14 0.118

+/-1.14 0.275 pCi/g Radium-226 0.573

+/-0.0981 0.0327 +/-0.0981 0.0696 pCi/g Silver-I08m U -0.00575

+/-0.0199 0.0169 +/-0.0199 0.0357 pCi/g Thallium-208 0.215

+/-0.0463 0.0168 +/-0,0463 0.0358 pCi/g The following Prep Methods were performed Method Description Analyst Date Time Prep Batch Dry Soil Prep Dry Soil Prep GL-RAD-A-021 LXM2 09/20/06 1536 570843 The following Analytical Methods were performed Method Description EML HASL 300,4.5.2.3 Notes:

The Qualifiers in this report are defined as follows:

A quality control analyte recovery is outside of specified acceptance criteria Result is less than value reported 58

GENERAL ENGINEERING LABORATORIES, LLC 2040 Savage Road Charleston SC 29407 - (843) 556-8171 - www.gel.comr Certificate of Analysis Company:

Connecticut Yankee Atomic Power

  • Address.:

362 Injun Hollow Rd East Hampton, Connecticut 06424 Report Date: October 4, 2006

Contact:

Mr. Jack McCarthy

  • Project:.

Soils PO# 002332 Client Sample ID:

9530-0001-006F Proiect:

YANKO01204 Sample ID:

172114013 ClientID:

YANK001 Vol. Recv.:.

Para, meter Qualifier Result Uncertainty LC TPU M,)A Units DF Analyst Date Time Batch Mt Result is greater than value reported A

The TIC is a suspected aldol-condensation product B1 Target analyte wasdetected in the associated blank BD Results are either below the MDC or tracerrecovery is low C

Analyte has been confirmed by GC/MS analysis D

Results are reported from a diluted aliquot of the sample:

H Analytical holding time was exceeded J

Value is estimated N/A: Spike recovery limits do0*not apply. Sample concentration exceeds spike concentration by 4X or more

.R Sample results are rejected U

Analyte was analyzed for, but not detected above the MDL, MDA, or LOD.

UI Gamma Spectroscopy-Uncertain identification X

Consult Case Narrative, Data Summary package, or Project Manager concerning this qualifier Y

QC Samples were not spiked with this compound A

RPD of sample and duplicate evaluated using +/-RL. Concentrations are <5X the RL h

Preparation or preservation holding time was exceeded The above sample is reported on a dry weight basis.

59

GENERAL ENGINEERING LABORATORIES, LLC 2040 Savage Road Charleston SC 29407 - (843) 556-8171 - www.gel.com Certificate of Analysis Company Connecticut Yankee Atomic Power Address:

362 Injun Hollow Rd East Hampton., Connecticut 06424

Contact:

Mr. Jack McCarthy Project:

Soils PO# 002332.

Report Date:

October 4, 2006 Client Sample ID:

Sample ID:

Matrix:

Collect Date:

Receive Date:

Collector:

Moisture:

9530-0001-0306FS 172114014 TS:

08-SEP-06 20-SEP-06 Client 11.7%

Proiect:

Client ID' Vol. Recv.:

YANK01204 YANK001 Parameter Qualifier Result Uncertainty LC TPU

.MDA Units.

DF Analyst Date Time Batch Mt Rad Gamma Spec Analysis Gamma.SoliM-FSS GAM & ALL FSS 2261hgrowth:

Waiwed.

Actinium-228 0.926

.+1-0.246 Americium-241 U

-0:0132

+/-0.0396 Bismuth92.12 0.646 -

+1-0.345 Bismuth-214

.0.585

+1-0.128 Cesium-134 U

0.0555

+/-0.0388 Cesium.137 0.124

+/-0.0454 Cobalt-60 U

0.0178

+/-0.0345 Europium-152.

U -0.00696

+/-0.076 Europium-154 U -0.0305

+/-0.0976 Europium-I155 U

0.0424.

+/-0.0757.

Lead-212

'0.684

+/-0.0847*

Lead-214**

0.642

+/-0.132 Manganese-54 U

0.0102

+/-0.0367 Niobium-94 U

0.0207

+/-0.0303 Potassium-40 12.7

+/-1.11 Radium-226 0.585

+/-0.128 Silver-108m U-0.000565

+/-0.026 Thallium-208 0.241

+/-0.0641 0.104 0.0331 0.196 0.052 0.0355 0.0307 0.0302.

0.0627 0.0786 0.0551 0.0486 0.0463 0.0272 0.0265 0.250 0.052 0.0227 0.0271

.+/-0.246

+ /-0.0396

+/-0.345

+/-01 t28

+/-0.0388

+/-0.0454

+/-0.0345

+/-0.076

+/-0.0976

+/-0.0757

.+/-0.0847

+/-0.132

+/-0.0367

+/-0.0303

+1-1.11

+/-0.128

+/-0.026

+/-0.0641

.. 0.221

..0.0683 0.418 0.110 0.0749

.0.0647 0.0655 0.131 0.171 0.114 0.100 0.097 0.058 I 0.056 0.551 0.110 0.0477 0.0573 pCi/g pCi/g pCqg pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pci/L pCi/g pCi/g pCilg pCi/g pCi/ga MJH1 I0/02/0609201574334 The following Prep Methods were performed Method Description Analyst Date Time Prep Batch Dry Soil Prep Dry Soil Prep GL-RAD-A-021 LXM2 09/20/06 1536 570843 The following Analytical Methods were performed Method Description 1

EML HASL 300, 4.5.2.3 Notes:

The Qualifiers in this report are defined as follows:

A quality control analvle recovery is outside of specified acceptance criteria Result is less than value reported 60

GENERAL ENGINEERING LABORATORIES, LLC 2040 Savage Road Charleston SC 29407 - (843) 556-8171 - www.gel.com Certificate of Analysis Company.

Connecticut Yankee Atomic Power Address:

362 Injun Hollow Rd East Hampton, Connecticut 06424 Report Date: October 4, 2006

Contact:

Mr. Jack McCarthy Project:

Soils PO# 002332 Client Sample ID:

9530-000l-006FS Project:

YANK01204 Sample ID:

17211401.4 Client ID:

YANK001 Vol. Recv.:

Parameter Qlualifier Re*sult Uncertainty LC TPU "VIDA Units DF Analyst Date Time Batch Mt Result is greater than value reported AI The TIC is a Suspected aldol-condensation product 3B Target analyte was detected in the associated blank BD ResulIts are' either below the MDC or tracer recovery is low C.

Analyte has been confirmedby GC/MS analysis D.Results are:reported from a diluted aliquot of the sample H

Analytical holding time was exceeded J

Value is estimated N/A Spike recovery limits do not apply. Sample concentration exceeds spike concentration by 4X or more

.R Sample results are rejected U.

Analyte wasanalyzed for, but not detected above the MDL, MDA, or LOD.

UT Gamma Spectroscopy--Uncertain identification X

Consult Case Narrative, Data Summary package, or ProjectManagercotncerning this qualifier Y

QC Samples were not spiked with this compound A

RPD of sample and duplicate evaluated using +/-RL. Concentrations are <5X the RL h

Preparation or preservation holding time was exceeded The above sample is reported on a dry weight basis.

61

GENERAL ENGINEERING LABORATORIES, LLC 2040 Savage Road Charleston SC 29407 - (843) 556-8171 - www:gel.com Certificate of Analysis Company:, Connecticut Yankee Atomic Power Address :,

362 Injun Hollow Rd

Contact:

Project:

East Hampton, Connecticut 06424 Mr. lack McCarthy Soils PO# 0027332 Report Date: October 4. 2006 Client Sample ID:

Sample ID:

Matrix:

Collect Date:

Receive Date:

Collector:

Moisture:

9530-0001 -007F 172114015 TS 08-SEP- 06 20-SEP-06 Client 14.1%

Proiect:

Client ID:

Vol. Recv.:

YANKO 1204 YANK001 Parameter.

Qualifier Result Uncertainty LC TPU MDA Units DF Analyst Date Time Batch Mt Rad Gamma Spec Analysis GammnaSolid-SS GAM & ALL ESS,226 Ingrowth Waived Actinium-22. 8 Americium-241 Bismuth-212 Bismuth-214 Cesium-134 Cesium--w137 Cobalt-60 Europium 152 Europium-154 Europium-155 Lead-212 Lead-2 14 Manganese-54 Niobium-94 Potassium-40 Radium-226 Silver-108m Thallium-208 0.645 U

0.0595 0.977

  • 0.605 UI 0.00 0.134 U

0.0203 U

-0.0415 U

-0.0289 U

  • 0.0877 0.881 0.585 U

0.0176 U

-0.015 13.4 0.605 U

0.00285 0.274

+/-0.261

+/-0.0378

+/-0.392

+/-0.123

+/-0.046

+/-0.0553

+/-0.0343

+/-0.0688.

+/-0.104

+/-0.0987

+/-0.0767

+/-0.0315

+/-0.0315

+/-0.0302

+/-1.18

+/-0.123

+/-0.0254

+/-0.051 0.0854 0.0357

0.207 0.0471 0.0365 0.;0297 0.0308 0.0578 0.0839 0.0524

.0.0318 0.0434 0.0274 0.024 0.185 0.0471 0.0221 0.024

  • .-I-0:261 "

/-0.0378

+/M.392

+/-0.123

+/-0.046

+/4-0.0553

+/-0.0343.

+/-0.0688

+/-0.104

+/-0.0987

+/-0.0767

+/-0:111

+/-0.0315

+/-0.0302

+/-1.18

+/-0.123

+/-0.0254

+1-0.051 0.187

.0.0737 0.446 0.101 0.0777 0.0634

.0.068 0.123 0.185

.0.109 0.0668 0.0917 0.0592 0.0515 0.434 0.101 0.0469 0.0517

.pC/g pCi/g pCi/g pCi/g pCt/g pCi/g pCi/g pci/g pudg pCilg pCi/g pCi/g pCi1g pCi/g MJHI :10/02/060921 574334 1

The following Prep Methods were performed Method Description Analyst Date Time Prep Batch Dry Soil Prep Dry Soil Prep GL-RAD-A-021 LXM2.

09/20/06 1536 570843 The following Analytical Methods were performed Method Description I

EML HASL 300, 4.52-3 Notes:

The Qualifiers in this report are defined as follows:

A quality control analyte recove'y is outside of specified acceptance criteria Result is less than value reported 62

GENERAL ENGINEERING LABORATORIES, LLC 2040 Savage Road Charleston SC 29407 - (843) 556-8171 - www.gel.com Certificate of Analysis Company Connecticut Yankee Atomic Power Address:

362 Injun Hollow Rd East Hampton, Connecticut 06424 Report Date: October 4, 2006

Contact:

Mr. Jack McCarthy Project:

Soils PO# 002332 Client Sample ID:

9530-0001-007F Project:

YANKO01204 Sample ID:

172114015 ClientD:

YANKOO I Vol. Recv.:

I'arameter Qualifier Result Uncertainty LC TPU Nif)A Units DF Analyst Vate Time Batch Mt.

Result is greater than value reported A

The TIC is a suspected aldol-condensation product.

B Target analyte was detected in the associated blank BD Results are either below: the MDC or tracer recovery is low.

C Analyte has been confirmed by GC/MS analysis D

Results are reported from a diluted aliquot of the sample H

Analytical holding time was exceeded J

Value is estimated N/A Spike recovery limits do not apply. Sample concentration exceeds spike concentration by 4X or more Sample results are rejected U

Analyte was analyzed for, but not detected above.the MDL, MDA, or LOD.

UI Gamma Spectroscopy--Uncertain identification X

Consult Case Narrative, Data Summary package, or Project Manager concerning this qualifier Y

QC Samples were not spiked with this compound A

RPD of sample and duplicate evaluated using +/-RL. Concentrations are <5X the RL h

Preparation or preservation holding time was exceeded The above sample is reported on a dry weight basis.

63

GENERAL ENGINEERING LABORATORIES, LLC 2040 Savage Road Charleston SC 29407 - (843) 556-8171 - www.gel.com Certificate of Analysis Company:

Connecticut Yankee Atomic Power Address:

362 Injun Hollow Rd East Hampton, Connecticut 06424

Contact:

Mr. Jack McCarthy Project:

Soils PO# 002332 Report Date: October 4. 2006 Client Sample ID:

Sample ID:

Matrix:

r Collect Date:

Receive Date:

Collector:

Moisture:

9530-0001-009F 172114016

/

TS 08-SEP-06 20-SEP-06 Client 12.8%

Project:

Client ID:

Vol. Recv.:

YANKO 1204 YANKOOI Parameter Qualifier Result Uncertainty LC.

TPU MDA Units DF Analyst Date Time Batch. Mt Rad Gamma Spec Analysis Gamma;SoId-FSS GAM & ALL FSS 226 Ingrowth Waived Actiniuim-228

  • AmeIriciUm-24 I Bismuth-212 Bismuth-214 Cesium-134 Cesium-I 37

.Cobalt-60 Europium-152 Europium-154 Europium-155 Lead-212 Lead-214 Manganese-54 Niobium-94 Potassium-40 Radium-226 Silver-108m Thallium-208 1 0.853 U

0.0188 0.391 0.511 U

0.02232 0.0641 U 0.00129 U

0.0365 U -0.00251 U

0.0286 0.667 0.626 U

0.0317 U

-0.0013 13.0 0.511 U

0.0146 0.217

+/1-0.145

+/-0.113 L/-0.278

+/-0.0924

+/-0.0242

+/-0.0413

+/-0.0198

+/-0.0526

+/-0.0619

+/-0.0599

+/-0.0687

+/-0.0869

+/-0.0253

+/-0.0177

+/-0.831

+/-0.0924

+/-0.0167

+/-0.0483 0.0559 0.0925 0.121 0.0314 0.0185 0.0188 0.0169 0.0423 0.0452 0.0534 0.0337 0.0313 0.0153 0.0152 0.143 0.0314 0.015 0.0146

+/-0.145

+/-0.11i3

+/-0.278

+/-0.0924

+/-0.0242

+I-0.041 3

+/-0.0198

+/-0.0526

+/-0.0619

+/-0.0599

+/-0.0687

+/-0.0869

+/-0.0253

+/-0.0177

+/-0.831

+/-0.0924

+/-0.0167

+/-0.0483

0. 12o0 0.192 0.257 0.0663 0.0394 0.0395 0.0368 0.0888 0.0987 0.111 0.0695 0.0656 0.0328 0.0321 0.315 0.0663 0.0315 0.0311 pCi/g pCi/g pci/ýý pCilg pCi/g pCi/gl pCi/g:

pCi/g pCi/g pci!/g pci/g pCilg pCi/g pCi/g pCi/g pCilg pCi/gC pCi/gI MJHI 10/02/060921,574334r I

The following Prep Methods were performed Method Description Analyst Date Time Prep Batch Dry Soil Prep Dry Soil Prep GL-RAD-A-021 LXM2 09/20/06 1536 570843 The following Analytical Methods weut performed Method Description I

EML HASL 300,4.5.2.3 Notes:

The Qualifiers in this report are defined as follows:

A quality control analyte recovery is outside of specified acceptance criteria Result is less than value reported 64

GENERAL ENGINEERING LABORATORIES, LLC 2040 Savage Road Charleston SC 29407 - (843) 556-8171 - www.gel.com Certificate of Analysis Company Connecticut Yankee Atomic Power Address :

362 Injun Hollow Rd East Hampton, Connecticut 06424 Report Date: October 4, 2006 Contact' Mr. Jack McCarthy

.Project:

Soils PO# 002332 Client SampleID:

9530-0001-009F Proiect:

YANK01204 SamplelD:

172114016

..ClientiD:

YANKOO I Vol. Recv.:

Parameter Qualifier Result Uncertainty LC TPU MDA Units DF Analyst Date Time Batch Mt Result is greater than value reported A

The TIC is a suspected.aldol-condensation product B. Target analyte was detected in the associated blank.

BD Results are either below the MDC or tracer recovery is low C

Analyte has been confirmed by GC/MS analysis D

Results are reported from a diluted aliquot of the sample H

Analytical holding time was exceeded J

Value is estimated N/A Spike recovery limits do not apply. Sample concentration exceeds spike concentration by 4X or more R

Sample results are rejected, U

Analyte was analyzed for, but not detected above the MDL, MDA, or LOD.

UL Gamma Spectroscopy--Uncertain identification X

Consult Case Narrative, Data Summary package, or Project Manager concerning this qualifier Y

QC Samples were not spiked with this compound A

RPD of sample and duplicate evaluated using +/-RL. Concentrations are <5X the RL h

Preparation or preservation holding time was exceeded The above sample is reported on a dry weight basis.

65

GENERAL ENGINEERING LABORATORIES, LLC 2040 Savage Road Charleston SC 29407 - (843) 556-8171 - www.gel.com Certificate of Analysis Company:

Connecticut Yankee Atomic Power Address:

362 !njun Hollow Rd East Hampton, Connecticut 06424 Contact-.

  • Mr. Jack McCarthy Project:

Soils PO# 002332 Report Date:

October 4, 2006 Client Sample ID:

Sample ID:.

Matrix:

Collect Date:

Receive Date:

Collector:

Moisture:

9530-0001-013F.

172!114017 *.*

TS 08-SEP-06 20-SEP-06 Client 16.6%

Project:

Client ID:

Vol. Recv.:

YANKO 1204

  • YANKOO I Parameter Qualirter* Result Uncertainty LC TPU MIDA Units DF Analyst Date Time Batch Nit Rad Gamma Spec Analysis Gamtna, Solid-FSSGAM & ALL FSS 226 Ingrowth.

waiie.

Actinium-228 0.740

.+/-0.127 Americium-241 U, 0.00362

+/-0.0583 Bismuth-212.

0-387 i/-0.189 B ismuth-214 0.525

+/-0.0781 Cesium-134 U

0.023

+/-0.022 Cesium-137 0.0729

+/-0.0276 Cobalt-60

  • UI 0.00

+/-0.0373 Europium-152 U -0.0476

+/-0.0396 Europium-154 U 0.000881.

+/-0.0505 Europium-155 U

0.016

.+/-0.0515 Lead-212 0.589

+/-0.0732 Lead-214 0.570

+/-0.065 Manganese-54 U

0.0012

+/-0.0157 Niobium-94 U -0.00299

+/-0.0143 Potassium-40 12.4

+/-0.724 Radium-226 0.525

+/-0.0781 Silver-108m U 0.00791

+/-0.0139 Thallium-208 0.218

+/-0.0361 0.0409

'0.053 0.0995 0.0268 0.017 0.0153 0.0138 0.0323 0.0419 0.0458 0.0307 0.027 0.0136 0.0123 0.106 0.0268 0.0123 0.0143

+/A. 127

+/-0.0583

+/-0:189

+/-0.0781

+/-0.022

+/-0.0276.

+/-0.0373

+/-0.0396

+1-0.0505

+/-0.0515

+/=0.0732

+/-0.065

+/-0.0157

+/-0.0143

+/-0.724

+/-0.0781

+/-0.0139

+/-0.0361 0.0882.

0u109 0.212 0.0564 0.036 0.0322 0.0301 0.0679 0.0903 0.0945 0.0629 0.0564 0.029 0.06 G.235 0.0564 0.0259 0.0301 pCi/gU pCi/g pci/g pCi/ga pCi/g pCi/g pCi/g pCii/g pCi/g pCi/g pCi/ga pCi/g pCilg p)0/g pCi/g-pCilg MJHI 10/02/06 0922 574334.

1 The following Prep Methods were performed Method Description Analyst Date Time Prep Batch Dry Soil Prep Dry Soil Prep GL-RAD-A-021 LXM2 09/20/06 1536 570843 The following Analytical Methods were performed Method Description I

EML HASL 300,4.5.2.3 Notes:

The Qualifiers in this report are defined as follows:

A quality control analyte recovery is outside of specified acceptance criteria Result is less than value reported 66

GENERAL ENGINEERING LABORATORIES, LLC 2040 Savage Road Charleston SC 29407 - (843) 556-8171 - www.gel.com Certificate of Analysis Company:

Connecticut Yankee Atomic Power Address:

362 Injun Hollow Rd East Hampton, Connecticut 06424 Report Date: October 4, 2006

Contact:

Mr. Jack McCarthy Project:

Soils PO# 002332 Client Sample ID:

9530-0001-013F Proiect:.

YANK01204 Sample ID:

172114017 ClientID:

YANK001 Vol. Recv.:

Parameter "u,.,,..r Result Uncertainty LC TPU MDJA Units DF Analyst Date Time Batch Mt Result is greater than value reported

.A The TIC is a suspected aldol-condensation product B

Target analyte was detected in the associated blank 11BD Results are either below the MDC or tracer recovery is low C:

Analyte has been confirmed by GC/MS analysis..

D Restilts are reported from a diluted aliquot of the sample H

Analytical holding time was exceeded J

Value is estimated N/A Spike recovery limits do not apply. 'Sample concentration: exceeds spike concentration by 4X or more R.. Sample results are rejected U

Analyte was analyzed for, but not detected above the MDL, MDA, or LOD.

UI Gamma Spectroscopy--Uncertain identification X

Consult Case Narrative, Data Summary package, or Project Manager concerning this qualifier Y

QC Samples were not spiked with this compound A

RPD of sampleand duplicate evaluated using +/-RL. Concentrations are <5X the RL h

Preparation or preservation holding time was exceeded The above sample is reported on a dry weight basis.

67

GENERAL ENGINEERING LABORATORIES, LLC 2040 Savage Road Charleston SC 29407 - (843) 556-8171 - www.gel.comr Certificate of Analysis Company:

Connecticut Yankee Atomic-Power Address :

362 Injun Hollow Rd

Contact:

Project:

East Hampton. Connecticut 06424 Mr. Jack McCarthy Soils PO# 002332 Report Date:

October 4. 2006 Client Sample ID:

Sample ID:

M a tr ix : *...

Collect Date:

Receive Date:

Collector:

Moisture:

9530-0001-01 4F

.172114018 TS 08-SEP-06 20-SEP-06 Client 13.6%

Proiect:

Client ID:

Vol. Recv.:

YANKO 1204 YANK001

  • Parameter Qualifier Result Uncertainty LC TPU MDA Units DF Analyst Date Time Batch M1 Rad Gamma Spec Analysis.

Gamma.Solid-FSS GAM & ALL FSS 226 Ingrowth.

Waived Actinium-228 0.770

+1-0.212 0.0859

+/A-.212 0.172 pCi/g

MJHI 10/02/06 1023*574334 Americium-241 U

0.035:

+/-0.040..

0.0324

+/-0.040 0.0648" pCi/g Bismuth-212.

0.700

+/-0.298 0.205

+/-0.298 0.411 pCi/g Bismuth-214 0.596

+/-0.126 0.0446

+/-0.126 0.0892 pCi/g Cesium-134 U

0.0156

+/-0.0351 0.0314 +/-0.0351 0.0628 pCi/g Cesium-137 0.0547

+/-0.0528

.0.0254 +/-0.0528" 0.0507 pCi/g.

-.Cobalt-60 U

0.00268.

+/-0.0347 0.0291

+/*0.0347 0.0582 pCi/g

  • Europium-152 U

-0.0696

+1-0.0936, 0.0564 ÷/-0.0936 0.113 pCi/g' EUropium-154 U

-0.0999

+/-0.101 0.0729

+/-0.101 0.146 pCi/g Europium-155 U

0.00172

+/-0.0565 0.0492 +/-0.0565 0.0982 pCi/g Lead-2 1 2 0.657*,

+/-0.086 0.0312

+/-0.086 0.0623 pCitg Lead-214 0.609

+/-0.10.7 0.0404

+/-0a107 0.0808 pCi/g Manganese-54 U -0.0127

+/-0.0309 0.0214 +/-0.0309 0.0428 pCi/g Niobium-94 U

-0.0162

+/-0.0257 0.0211 +/-0.0257 0.0423 pCi/g Potassium-40 12.5

+/-1.31 0.251

+/-1.31 0.501 pCi/g Radium-226 0.596

+/-0.126 0.0446

+/-0.126 0.0892 pCi/g Silver-108m U

-0.017

+/-0.0234 0.0189 +/-0.0234 0.0378 pCi/g Thallium-208 0.202

+/-0.051 0.0228

+/-0.051 0.0456 pCi/g The following Prep Methods were performed Method Description Analyst Date Time Prep Batch Dry Soil Prep Dry Soil Prep GL-RAD-A-021 LXM2 09/20/06 1536 570843 The following Analytical Methods were performed Method Description EML HASL 300,4.5.2.3 Notes:

The Qualifiers in this report are defined as follows:

A quality control analyte recovery is outside of specified acceptance criteria Result is less than value reported 68

GENERAL ENGINEERING LABORATORIES, LLC 2040 Savage Road Charleston SC 29407 - (843) 556-8171 - www.gel.com Certificate of Analysis Company:

Connecticut Yankee Atomic Power Address:

362 injun Hollow Rd East Hampton, Connecticut 06424 Report Date: October 4. 2006

Contact:

Mr. Jack McCarthy Project:

Soils PO# 002332 Client Sample ID.

9530-000I-014F Project:

YANK01204 Sample ID:

172114018 Client ID:.

YANK001 PrmtrQu...r

-Uncertnt L:

"U I'fA Units DFAna"ystDte TimeBatchMtVol.R Parameter

"*vuanlier Result Uncertainty LC TPU MIDA Units DF Analyst Date Time Batch Nit Result is greater than value reported A

The TIC is a suspected aldol-condensation product B

Target analyte was detected in the associatedblank BD Results are either below the MDC or tracer recovery is low C

Analyte has been confirmed by GC/MS analysis D

Results are reported from a diluted aliquot of the sample H

Analytical holding time was exceeded J

Value is estimated N/A Spike recovery limits do not apply, Sample concentration exceeds spike concentration by 4X or more R

Sample results are rejected U

Analyte was analyzed for, but not detected above the MDL, MDA, or LOD.

UI Gamma Spectroscopy--Uncertain identification X

Consult Case Narrative, Data Summary package, or Project Manager concerning this qualifier..

Y QC Samples were not spiked with this compound A

RPD of sample and duplicate evaluated using +/-RL. Concentrations are <5X the RL h

Preparation or preservation holding time was exceeded The above sample is reported on a dry weight basis.

69

GENERAL ENGINEERING LABORATORIES, LLC 2040 Savage Road Charleston SC 29407 - (843) 556-8171 - www.gel.com Certificate of Analysis Company:

Connecticut Yankee Atomic Power Address :

362 Injun Hollow Rd East Hampton, Connecticut 06424

Contact:

Mr. Jack McCarthy Project:

Soils PO# 002332 Report Date: October 4, 2006 Client Sample ID:

Sample ID:

Matrix:

Collect Date:

Receive Date:

Collector:

Moisture:

9530:-0001-014FS 172114019,.

TS 08-SEP-06 20-SEP-06 Client 13.5%

Project:

Client ID:.

Vol. Recv.:

YANK01204 YANKOO I Parameter Qualifier Result Uncertainty LC TPU.

AJDA Units DF Analyst Date Time Batch Mt, Rad Gamma Spec Analysis GanznaSlMid-FSS GAM & ALL. FSS 226 Ingrowth Waived Actinium-228 0.724

+/-0.183,

  • Americium-241.

-0.0361

+/-0.0949 Bismuth-212 0.449

+/-0.308 Bismuth-214 0.511

+/-0.103 Cesium-134 U!

0(00

+/-0.0439 Cesium-137 0.0729

+/-0.0406 Cobalt-60 U

0.00586

+/-0.0236.

EuLropium-152 U

-0.0409

+/-0.0665 Europium-154 U

-0.0391

+/-0.0666 Europium-155 U

0.0598

+/-0.0586 Lead-212 "

0.781

+/-0.070 Lead-214 0.632

+/-0.0979 Manganese-54 U

0.00384

+/-0.0213 Niobium-94 U

0.0031

+/-0.0192 Potassium-40 12.2

+/-1.08 Radium-226 0.511

+/-0.103 Silver-108m U

0.0222

+/-0.0184 Thallium-208 0.294

+/-0.0515 0.0614 0.0756 0.153 0.0328 0.0268 0.0199 0.0208

.0.0458 0.0524 0.0541 0.0285 0.0363 0.0182 0.0165 0.139 0.0328 0.0175 0.0166

+/-0.183

+1-0;0949

+/-0.308

+/-0.103

+/-0.0439

+/-0.0406

+/-0.0236

+/-0.0665

+/-0.0666

+/-0.0586

+/-0.070

+/-0.0979

+/-0.0213

+/-0.0192

+/- 1.08

+/-0.103

+/-0.0184

+/-0.0515

.0.135 0.157

  • 0.330 0.0708 0.0572 0.0428 0.0465 0.0973 0.118 0.112 0.0597.

0.0768 0.0397 0.0358 0.327 0.0708 0.0373 0.0359 pCi/g

.pCi/g pCi/p pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g P ci/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g MJHI 10/02/06 1344 574334, 1

The following Prep Methods were performed Method Description Analyst Date Time Prep Batch Dry Soil Prep Dry Soil Prep GL-RAD-A-021 LXM2 09/20/06 1536 570843 The following Analytical Methods were performed Method Description I

EML HASL 300, 4.5.2.3 Notes:

The Qualifiers in this report are defined as follows:

A quality control analyte recovery is outside of specified acceptance criteria Result is less than value reported 70

GENERAL ENGINEERING LABORATORIES, LLC 2040 Savage Road Charleston SC 29407 - (843) 556-8171 - www.gel.com Certificate of Analysis Company:

Connecticut Yankee Atomic Power Address:

362 Injun Hollow Rd.

East Hampton, Connecticut 06424 Report Date: October 4, 2006

Contact:

Mr. Jack McCarthy

'Project:

Soils PO# 002332 Client Sample ID:

9530-0001-014FS Project:

YANKO 1204 Sample ID:

.172114019.

Client ID:

YANKOOI Vol. Recv.:

Paraet Vu Uncertainty LC TPU M[A Units DF Analyst Date Time Batch Nit Resultis greater than value reported A

The TIC-is a suspected aldol-condensation product B

Target analyte Was detected in the associated blank BD.Results are either.below the MDC or tracer recovery. is low C

Analyte has been confirmed by GC/MS analysis D

Results are reported from a diluted aliquot of the sample H

Analytical holding time was exceeded J

Value is estimated N/A Spike recovery limits do not apply. Sample concentration exceeds spike concentration by 4X or more R

Sample results are rejected U

Analyte was analyzed for, but not detected above the MDL, MDA,'or LOD.

UT Gamma Spectroscopy--Uncertain identification X

ConstultCase Narrative, Data Summary package, or Project Manager concerning this qualifier Y

QC Samples were not spikedwith this compound A

RPD of sample and duplicate evaluated using +/-RL. Concentrations are <5X the RL h

Preparation or preservation holding time was exceeded The above sample is reported on a dry weight basis.

71

GENERAL ENGINEERING LABORATORIES, LLC 2040 Savage Road Charleston SC 29407 - (843) 556-8171 - www.gel.comr Certificate of Analysis Company Connecticut Yankee Atomic Power Address:

362 Injun Hollow Rd East Hampton, Connecticut 06424

Contact:

Mr. Jack McCarthy Project:

Soils PO# 002332 Report Date: October 4, 2006 Client Sample ID:

Sample ID:

Matrix:

Collect Date:

Receive Date:

Collector:

Moisture:

9530-0001-015F 172114020 TS 08-SEP-06 20-SEP-06 Client 11.3%

.Project:

Client ID:

Vol. Recv.:

YANKO 1204, YANKOOI Parameter Qualifier Result Uncertainty LC TPU.

M1DA Units DF Analyst Date Time Batch Mt Rad Gamma Spec Analysis GammaiSolid-FSS GAM & ALL FSS 226 Ingi'owth Waived Actinium-228 0.644.

+/-0.161 Americiumim-241 U

-0.0336

+/-0.109 Bismuth-212 0.569'

+/-0.273 Bismuth-214 0.449

+/-0.0867 Cesium-134 U

0.0226

+/-0.0592 Cesium-137 0.0415

+/70.0554 Cobalt-60 U

0.00214

+/-0.021 iEturpium-152 U

-040102

+/-0.0545 Europium-154 U

-0.0195

+/-0.0706 Europium-155 U

.0.0685

+/-0.0967

  • Lead-212 0.695

" 4-/-0.065 Lead-2 14 0.496

+4-0.0794 Manganese-54 U

0.0025

+/-0.0231 Niobium-94 U

0.00735

+/-0.0205 Potassium-40 12.0

+/-0.924 Radium-226 0.449

+/-0.0867 Silver-108m U

-0.0174

+/-0.0168 Thallium-208 0.218

+/-0.0517 0.0631 0.0844

-0.122 0.0328 0.0218 0.0185.

0.0179 0.0452 0.0576

.0.0485 0.0273 0.0352 0.0194 0.0179 0.137 0.0328 0.0136 0.0177

+1-0.161

+1-0.1 09

+/-0.273

+/-0.0867

+/-0.0592

+/-0.0554

+1-0.021

+/-0.0545

+/-0.0706

+/-0.0967

+/-0.065

+1-0.0794

+/-0.023 I

+1-0.0205

+/-0.924

+/-0.0867

+/-0.0168

+/-0.0517 0.138 "0.1'76 0.266 0.0703 0.0468 0.03.97 0.0403 0.0957 0.127 0.101 0.0571 0.0743 0.042 0.0383 0.318 0.0703 0.0293 0.0379 401.

pCi/ga pCilg pCi/gV pCilg pCi/gM pCi/g0 pCi/g pu~g pCilga pCi/g0 pCi/g0 pCi/g pCg pCi~g MJH 1.0/02/06 1345 57433:4 The following Prep Methods were performed Method Description Analyst Date Time Prep Batch Dry Soil Prep Dry Soil Prep GL-RAD-A-02.1 LXM2 09/20/06 1536 570843 The following Analytical Methods were performed Method Description I

EML HASL 300,4.5.2.3 Notes:

The Qualifiers in this report are defined as follows:

A quality control analyte recovery is outside of specified acceptance criteria Result is less than value reported 72

GENERAL ENGINEERING LABORATORIES, LLC 2040 Savage Road Charleston SC 29407 - (843). 556-8171 -www.gel.com Certificate of Analysis Company.:

Connecticut Yankee Atomic Power Address :

362 Injun Hollow Rd East Hampton, Connecticut 06424 Report Date: October 4, 2006

Contact:

Mr. Jack McCarthy Project:

Soils PO# 002332 Client Sample ID:

9530-0001-015F:

Proiect:

YANK01204 Sample ID:

172-114020 Client ID'. YANK001 Vol. Recv.:

Parameter Qualifier Result Uncertainty LC TPU rM.DA Units 11 Analyst Date Time Batch Mt.

Result is greater than value reported A

The TIC is a suspected aldol-condensation product B._ Target analyte was detected in the associated blank BD Results are either below the MDC or tracer recovery is low C

Analyte has been confirmed by GC/MS'analysiS D

Results are reported from a diluted aliquot of the sample H

Analytical holding time was exceeded J

Value is estimated N/A Spike recovery limits do not apply. Sample concentration exceeds spike concentration by 4X or more

  • R Sample results are rejected U

Analyte was analyzed for, but notdetected above the MDL, MDA, or LOD.

UI Gamma Spectroscopy-Uncertain identification X

Consult Case Narrative, Data Summary package, or* Project Manager concerning this qualifier Y

QC Samples were not spiked with this compound A

RPD of sample and duplicate evaluated using +/-RL. Concentrations are <5X the RL h

Preparation or preservation holding time was exceeded The above sample is reported on a dry weight basis.

73

QUALITY CONTROL DATA 74

GENERAL.ENGINEERING LABORATORIES, LLC 2040 Savage Road Charleston SC 29407 - (843) 556-8171 - www.gel.com QC Summary Client:

Connecticut Yankee Atomic Power 362 Injun Hollow Rd ReDort Date: October 4, 2006 Page 1 of 9 East Hampton, Connecticut

Contact:

Mr. Jack McCarthy Workorder:

172114 Parmname Rad Allpha Spec Batch

.572120 NOM.

Sample Qual

_QC Units RPD%

REC%

Range Anlst Date Time QC1201.191304 Americium-241.

172114001 DUP U

0.0864 Uncert:

+/0.105 TPU:

+/-0.106 U

0.00 Uncert:

+/-0.0553 TPU:

+/-0.0553 U

0.0664 Uncert:

+/-0.0911 TPU:

+1-0.0915 Curium-243/244 QQCI2OI191306 Americitim-241 LCS Ciiuriun-242 Curium-243/244 QC12Ol 191303 Americium-241 Curium-242 Curium-243/244 QC1201191305 Americium-241 MB 11.4 Uncert:

TPU:

Uncert:

TPU:

13.7 Uncert:

TPU:

Uncert:

TPU:

Uncert:

TPU:

Uncert:

TPU:

U 0.0.286

+/-0.0554

+1-0.0555 U

-0.0072

+/-0.0141

+!-0.0141 U

-0.00672

+/.0.0132

+/-0.0132

  • 12.6

+/-1.20

+/-1.96 U

0.0299

+/-0.0586

+/-0.0588

.14.4

+/-1.28

+/-2.18 U

0.00455

+/-0.0226

+1-0-0227 U

0.00

+/-0.0581

+/-0.0581 U

-0.0704

+/-0.0436

+/-0.0445 pCilg pCi/g pcilg pCi/g9 pci/g-pCilg-pCi/g-pcilge pC!i/g.

101 pCi/g 200 pCi/g 245 puig 105 (75%-125%)

(0% -100%)

TCI 09/28/06 11:56 (0%- 100%)

(0%7-100%)

IllI (75%-125%)

172114001 MS Curium-242 12.0 Uncert:

TPU Uncett:

TPU 14.5 Uncert:

TPU U

0.0864

+/-0.105

+/-0.106 U

0.00

+/-0.0553

+/-0.0553 U

0.0664

  • +/-0.0911

+/-0.0915 U

12.9

+/-1.10

+/-1.85

-0.0126

+--0.0175

+1-&.0175 14.4

.1-1.16

+,-2.03 108 (75%-125%)

Curium-243/244 99 (75%-125%)

Batch 572121 QC1201191308 172114001 DUP Plutonium-238 U

0.102 U

0.0358 pCilg 96 (0%- 100%)

TCI 09/28/06 11:56 75

GENERAL ENGINEERING LABORATORIES, LLC 2040 Savage Road Charleston SC 29407 - (843) 556-8171. - www.gel.corn QC Summary Workorder:

172114 Parmname Rad Alpha Spec Batch 572121 Pliutonium-239/240 QC1201191310 LCS Plutonium-238 Plutonium-239/240 QC1201191307 MB Plutonium-238 NOM Samplle _ual Page 2 of 9

_QC Units RPD%

REC%

Range Anlst Date Time Uncert:

+/-0.0996 TPU:

+/-0.100 U

0.062 Uncert:

  • +/-0.077 TPU:

+/-0.0773 Uncert:

TPU:

10.5 Uncert:

TPU:

+/-0.0808

+/-0*0809 U

-0.0313

+**0.0909

+/-0.091 U

0.0404

+/-0.0758

+/-0.0759 11.2

+/-1.07

+/- 1.73 U

0.00363 t+79)-0.114

+/-0. I 14 U

0.0618

+1-o.107

+.-

/-0.107 pCilg

.608 (0%- 100%)

,(75%-,125%)

PILutoniL[M-239/240 QC12Q]I191309 172114001 MS Plutonium-239 Plutonitim-239/240 Uncert:

TPU:

Uncert:

TPU:'

pCi/g pCi/g.

pCi/g-107 (75%-125%)

09/28/06 11:56 U

0.102 Uncert:

+/-0.0996 TPU:

+/-0.100 H1.1 U

0.062 Uncert:

+/-0.077 TPU:

+/-0.0773 U

6.10 Uncert:

+/-8.99 TPU:

+/-9.01

.U 0.0976

+/-0.102

+1-0.103 I1.9

  • +/-1.09

+/-1.79 (75%- 125%)

09/28/06 11:56 1*07. (75%-125%)

Batch 572122 QC1201191312 172114001 ýDUP PlUtonium-241 U

4.20

+1-8.54

+/-8.55 pCi/g 0

(0%- 100%)

TOC 09/29/0623:34 QC1201191314 LCS Plutonium-241 QC120119131t MB PlutoniUm-241 132 Uncert:

TPU:

Uncert:

TPU:

144 U

Uncert:

TPU:

112

+/-12.9

+/- 17.0 U

2.21

+/-8.86

+/-8.86 pCi/g pci/g-85 (75%-125%)

09/30/06 00:06 09/29/06 23:18 09/29/06 23:50 QC1201191313 172114001 MS Plutonium-241 Rad Gamma Spec Batch 574334 QC1201196534 172114006 DUP Actinium-228 6.10

+/-8.99

+/-9.01 141

+1-14.2 1-419.8 98 (75%-125%)

0.828 Uncert:

+/-0.191 0.724

+1-0.264 41-0264 pCi/g 13 (0% - 100%) MJHI 10/02/06 13:46 76

GENERAL ENGINEERING LABORATORIES, LLC 2040 Savage Road Charleston SC 29407 - (843) 556-8171 - www gel.com QC Summary Workorder:

172114 Parmname Rad Gamma Spec Batch 574334 Page 3 of 9 REC%

Range Anlst Date Time NOM Sample Qual

_QC_

Units RPD%

Americium-24 I

  • Bismuth-212
  • Eu'opium-154
  • Europium-155 TPU:

+/-0.191 U

-0.0107 Uncert:

+1-0.0746 TPU:"

+/-0.0746 0.881 Uncert:

+1-0.459 TPU:.

+/-0.459 0.612 Uncert:

+1-0..130 TPU:

+/-0.130 UI

.0.00 Uncert:

+/-0.0376 TPU:

+/-0.0376 0.182 Uncert:

+/-0.0483 TPU:

+/-0.0483 U

-0.00988 Uncert:

+/-0.0263.1 TPU:

+/-0.0263 U

0.0683 Uncert:

+/-0.0624 TPU:

+/-0.0624 U.

0.104 Uncert:

4-0.0885 TPU:

+/-0.0885 U

.0.0308 Uncent:

+/-0.0643 TPU:

+/-0.0643 0.882 Uncert:

+/-0.0991 TPU:

+/-0.0991 0.857 Uncert:

+/-0.131 TPU:

+1-0.131 U

0.000152 Uncert:

+/-0.0265 TPU:

+/-0.0265 u

0.(P279 Uncert:

+/-0.0215 TPU:

+1-0.0215 13.3 Uncert:

+1-1.37 TPU:

+1-1.37 0.612 Uncert:

+1-0.130 TPU:

+/-0.130 U

-0.00885 Uncert:

+/-0.0202 U

0.00921

+141.0404

+/-0.0404 0.621

+40.284

+1-0.284 0.719

.+1-0.131.

+1-0.131 U

(100367

+/-0.0364

+1-0.0364 0.227

+1-0.0551

+"-0.0551 U

-010M503

+1-0&0277

+1-0.0277 U

-0.1 12

+/-0.0713

+1-0.0713 U

0.0469

+1-0.0793

+/-0.0793 U

0.046

+/-0.0633

+/-0tg633

&876

+/41-.12

+/-0.0812 0.790

+/-0.136

+1-0:136 U

0.0209

+1-0.032,

+/-041328 UI 0.00

+1/-0533

+/-0&1533 14.6 Wk 19

+4-0.134

+/-0.131 U

-0.0074

+/-1.0243 pCi/g 2710 pCi/g 35 pci/g 16 pCi/g 184 pCi/g 22 pCi/g 65 pCi/g.

825 pCi/g 76 pCi/g 40 p00/g I

pCi/g 8

pCi/g 197 pCi/g 132 pCi/g 10 pCi/g 16 pCi/g 18 (0%- 100%)

(0%= 100%)

(0%- 100%)

(0%- 100%)

(0% - 100%)

(0%-100%)

(0-100%)

(0% - 1oo%)

(0%- 100%)

(0% - 20%)

(0%- 20%)

(0%- 100%)

(0% - 100%)

(0% - 20%)

(0%- 100%)

(0%- 100%)

Lead-21 2 Lead-214 Manganese-54 Niobilum-94 Potassium-40 Radiuin-226 Silver-losm 77

GENERAL ENGINEERING LABORATORIES, LLC 2040 Savage Road Charleston SC 29407 - (843) 556-8171 - www.gel.corn QC Summary Workorder:

172114 Parmname Rad Ganmna Spec Batch 574334 NOM SainpleQual___QCUnits RPD%

Page 4 of 9 REC%

Range AnIst Date Time Thallium-208 TPU:

+/-0.0202 0.282 Uncert:

+/-0.0618 TPU:.

+/-0.0618.

41-0.0243 0.260 41-0.0691 4-1-0.0691 pCi/g 8

(0%- 100%)

QC 1201196535 Actinium-228 Aniericium-241 LCS Bismuth-212 Bismuth-214 Cesium-134 Cesium-137 Cobalt-60 Europium-152 Europium-154 Europium-155 Uncert:

TPU:

23.4 Uncert:

TPU:

Uncert:

TPU:

Uncert:

TPU:

Uncert:

TPU:

9.56 Uncert:

TPU:

14.4 Unrcert:

TPU:

Uncert:

TPU:

Uncert:

TPU:

Uncert:

TPU:

Uncert:

TPU:

Uncent:

TPU:

Uncert:

TPU:

Uncert:

TPU:

U.

-0.0425

+/-0.520

+/-0.520 23.8

+i-1.09

+/-1.09 U

-0.416

+/-0.904

+1-0.904 U

-0.0594

+t-0.221 4/-0.221 U

0.0337 41-0.137

+1-0.137 10.2

+/-0.440

"/-0.440 15.0

.1-0.617 41.0.617 U

-0.0589

+1-0260 4.0260 U

0J123 4W-0.253 "1-0.253 U

0.0288

+1-0.280

+/-0.280 U

0.0247 41-0.147 4"-0.147 U

0.26 4M t;190 41-0.190 U

-0i37 4*1120 4M. 120 U

G00618

+/-0.112 4"-0.112 U

0.273 TOilg pCi/a0 pCi/g PCi/g PCi/ga pCilg' pCiJý'

pCilg pCi/gý pCi/g' Pci/g-PC,/g2 pCi/g PCi/g-pCilg-107 (75%-125%)

104 (75%7125%)

102 (75%-125%)

  • 10/02/06 13:46 Lead-212 Lead-214 NManganese-54 Niobitim-94 Potassium-40 78

GENERAL ENGINEERING LABORATORIES, LLC 2040 Savage Road Charleston SC 29407 - (843) 556-8171 - www.gel.corn QC Summary Workorder:

172114 Parmname RadGamma Spec Batch 574334 Page 5 of 9 REC%

Range AnIst Date Time NOM Sample-. Oual

_Qn__CUit RPD%

Radium-226 Silver-108m Thallium-208 QCI1201196533 Actinium-228 Americium2 I"

  • Bismuth-212 NIB Bismuth-214 Cesium-134 Cesium-137 Uncen:

TPU:

Uncert:

TPU:

Uncert:

TPU:,

Uncert:

TPU:

Uncerti TPU:

Uncert:

TPU::

Uncert:

TPU:

Uncert:

TPU:

Uncert:

TPU:

Uncert:

TPU:

Uncert:

TPU:

Uncert:

TPU:

Uncert:

TPU:

Uncert:

TPU:

Um.'cr:

TPU:

Uncert:

TPU:

+/-0.940

+/-0.940 U

-0.0594

+/-0.221

.+/-0.221 U

0.0133

+/-0.0983

+W-0.0983 U

-0.0156

+/-0.108

+/-0.108 U

'0.0198

+W-0.0496

+/-0.0496 U

0.0304

.1-0.0722

.,-0.0722 U:

'-0.0547

-W-0.097 41-0.097 U

0.0089

+1-0.02741

+1-0.0274 U

0.0013

+/-0.0141 I+/-4)0141

'U

-0.00185

+/-0.l0l2'

+/-"f,127 U

0.00854

+/-0.0131

+/40131 U

0.0369

+/-0.0388

+/-0.0388 U

&00458

+1/40366

+/4101366 U

-0.10598

+/-41.if42

+14111342 U

CLO149

+/-0j1"

+1-410456 U

0.00865

+/-0.0381

+/-0.0381 pCi/g pCi/g, pCilg pCi/ýg pci/g.

pCi/g-pCi/.g pCi/kg pCi/g.

pCi/g.

pCi/g 10/02/06 13:45 (75%-125%)

Cobalt-60 Europium-152 Europium-154 Europium-155 Lead-212 Lead-214 79

GENERAL ENGINEERING LABORATORIES, LLC 2040 Savage Road Charleston SC 29407 - (843) 556-8171 - www.gel.com Workorder:

172114 Parmname Rad Gamma Spec Batch 574334 Manganese-54 QC Summary Sample Qual

_QC Page 6 of 9 Range_ Anlist NOM Units RPD%

.REC%

Date Time Niobium-94 PotassiUm -40 Radium-226 Silver-108m Thallium-208 Rad GasFlow

.Batch Uncert:

TPU:

Uncert:

TPU:

Uncert::

TPU:

Uncert:

TPU:

Uncert:

TPU:

Uncert:

TPU:

U 0.00522

+1-0.0132

+1-0.0132 U

0.0114

-q-0.00966 41-0.00966 U,

0.0292

+/-0.282

" * -0.282 U

0.0089

+1-0.02_74

+/-0.0274 U

0.00301

+/-0.0115

+1*-0.0115 U

0.0143

/4-0.0139

".-0.O139 pCilg.

Pci/g.

pCi/g-pCi/0 571177.

QC1201189313 172114001 DUP Strontium-90 QC1201189315 Strontium-90 LCS U

0.00276 Uncert:

+/-0.00637 TPU:.

+/40.00637 1.74 Uncert:

TPU:

U 0,00958

+"-0.00698 4/-0.00699 pCi/g 0

(0%- 100%) KSDI 1.61 4J-0;0822 4-1100946 QC1201189312 MB Strontium-90 QC1201189314 172114001 MS Strontium-90 Rad Liquid Scintillation Batch 570929 QC1201188776 172114010 DUP h'on-55 QC1201188778 LCS Iron-55 Uncert:

TPU:

U QU 0716

+W-0.00594

+/-0.00594 PCVig pCi/g pCi/!!

93 (75%-125%)

09/29/06 23:36 09/30/06 08:48 09/29/06 23:36 09/30/06 08:48 1.74 U

Uncert:

.TPU:

0.00276

+/-0.00637

+/-0.00637 1.63

  • /-0.0859

+/-0.0982 94 (75%-125%)

U 12.2 Uncert:

+/-25.2 TPU:

+/-25.2 U

-0.391

+1-32.7 4-32.7

.-37

+/-45,3

+1-59.7 pCi/g 0

(0% - 100%) VlXPI 621 Uncert:

TPU:

pCi/i 86 (75%-125%)

09/27/06 14:03 09/27/06 14:36 10/03/06 05:37 QC1201188775 MB Iron-55 U

22.8 pCi/g 80

GENERAL ENGINEERING LABORATORIES, LLC 2040 Savage Road Charleston SC 29407 - (843) 556-8171 - www.gel.com QC Summary Workorder:

172114 Parniname Rad Liquid Scintillation Batch 570929 NOM Sample Qual Page 7 of 9 QC Units RPD%

REC%

Range Anist Date Time Uncert:

TPU:

QC1201188777 172114010 MS Ihon-55 699 U

Uncert:

TPU:

/ 12.2

+!-25.2

+/-25.2.

+/-41.7

+/-41.7 667

+1-45.8

+1-64.5 pCi/g

.95 (75%7125%)

09/27/06 14:19 Batch 570930 QC1201188781 172114010 DUP Nickel-63 QC1201t88783 LCS Nickel-63 U

-5.95 Uncert:

+/-10.8 TPU:

+/-10.8 U

2.04

+1-8.19

+/-8.19 pCi/g 0

(0%'- 100%) VIXPI

...QC1201188780 MB Nickel-63

512, Uncert:

TPU:

Uncert:

..TpU:

427

+/-21.0

+/-25.0 U

4.54

+/-10.3

+/-10.3 pci/gý pCi/g 83 (75%-125%)

09/25/06 17:07 09/25/06 17:40 09/25/06 16:50 09/25/06 17:23 QCt201188782 Nickel-63 172114010 MS

.571 Uncert:

TPU:

U

-5.95

+/-10.8

+/-10:8 Batch 570932

- QC1201188785 172114001 DUP Technetium-99 QC1201188787 LCS Technetiumn-99 QC1201188784 MB Technetium-99 QC1201188786 172114001 MS TechnetiUm-99

u.

0.0384 Uncert:

+/-0.285 TPU:

+/-0.285 u

467

+/-24.9

+/-29.5 0.0669

+/-0.286

+1-0286, 13.8

+/-0.523

+1-0.610 82 (75%-125%)

pCi/g 0

  • (0% - 100%) KXR I 12.7 Uncert:

TPU:

Uncert:

TPU:

U 0.0777

+/-0.247

+/-0.247 pCilg.

pCi/g-pCi/g0 109 (75%-125%)

09/29/06 17:06 09/29/06 17:39 09/29/06 16:50 09/29/06 17:23 13.1 Uncert:

TPU:

U 0.0384

+/-0.285

+/-0.285 Batch 570933 QC1201188789 172114001 DUP TritiUnt U

-5.59 Uncert:

+/-7.85 TPU:

+/-7.85 U

13.4

+441575

+1-04651

-223

-- 7..28

+/-7.28 49.4

+/-9.21

+1-925 pCi/g u

103 (75%-125%)

(0% - 100%) DFAI 09/25/06 02:59 09/25/06 03:31 QC1201188791 LCS Tritium 54.5 Uncert:

TPU:

pCi/g 91 (75%-125%)

81

GENERAL ENGINEERING LABORATORIES, LLC 2040 Savage Road Charleston SC 29407 - (843) 556-8171 - www.gel.corn QC Summary Workorder:

172114 Parmname Rad Liquid Scintillation Batch 570933 QC1201188788 MB" Tritium QC1201188790 172114001 MS

  • Tritium NOM Sample Qual Page 8 of 9

_QCC Units RPD%

REC%

Range Anlst Date Time Uncert:

TPU:,

U 1.22

+/-6.42

.+/-6.42 pCilga pCi/ga 09/25/06 02:42 09/25/06 03:15 54.5 U

Uncert:

TPU:

-5.59

+/-7.85

+/-7.85 41.0

+/-8.97

+/-9.00 75 (75%-125%)

Batch 570934 QCI201188793 172114010 DUP Carbon-14 QCI201188795 LCS Carbon-14 QC1201188792 MB Carbon-14 QC1201188794 172114010 MS Carbon-.14 U

0.00 Uncert:

+/-0.0813 TPU:

+/70.0813 U

-0.026

+/-0.0763

+/-0.0763, 6.32

+/-0.448

.+/-0.458 pCi/g 0

(0% - 100%) AXD2

.6.57 Uncert:

TPU:

Uncert:

TPU:

7.05 U

Uncert:

TPU:

-0.0391

+/-0.0746

+/-0.0746 pCi/g pCi/g.

pCi/g 96 (75%-125%)

09/23/06 16:34 09/23/06 17:34.

09/23/0)6 15:52.

09/23/06 17:17

.0.00

+/:0.0813

+/-0.0813 6.69

+)/-0.468

+/-0.479

.95 (75%-125%)

Notes:

The Qualifiers in this report are defined as follows:

A B

BD C

D H

J N/A R

U UI X

Y A quality control analyte recovery is outside of specified acceptance criteria Result is less than value reported Result is greater than value reported The TIC is a suspected aldol-condensation product Target analyte was detected in the associated blank Results are either below the MDC or tracer recovery is low Analyte has been confirmed by GCIMS analysis Results are reported from a diluted aliquot of the sample Analytical holding time was exceeded Value is estimated Spike recovery limits do not apply. Sample concentration exceeds spike concentration by 4X or more Sample results are rejected Analyte was analyzed for, but not detected above the MDL, MDA, or LOD.

Gamma Spectroscopy--Uncertain identification Consult Case Narrative, Data Summary package, or Project Manager concerning this qualifier QC Samples were not spiked with this compound RPD of sample and duplicate evaluated using +/-RL. Concentrations are <5X the RL 82

GENERAL ENGINEERING LABORATORIES, LLC 2040 Savage Road Charleston SC 29407 - (843) 556-8171 - www.gel.comr QC Summary Workorder:

172114 Page 9 of 9 Parmname NOOM SamQple Qual

_QC Units RPD%

REC%

Range AnIst Date Time A..

h Preparation or preservation holding time was exceeded N/A indicates that spike recovery limits do not apply when sample concentration exceeds spike cone. by a factor of 4 or more.

    • Indicates analyte is a surrogate compound.

A The Relative Peicent Difference (RPD) obtained from the sample duplicate (DUP),is evaluated against the acceptence criteria when the samnple is greater than.

five times (5X) the contract required.detection limit (RL). In cases where either the sample or duplicate value is less than 5X the RL a control limit of +- the RL is used to evaluate-the DUPresult.

Foi PS, PSD. and SDILT iesults, the values listed are the measured amounts, not final concentrations.

Where the analytical method has beenperformed under NELAP certification, the analysis has met all of the req.uiIrji s off the PELLC standaidiu uniless qualified on the QC S

  • i iary.

83

CENTRAL PENINSULA SURVEY UNIT 9530-0001 RELEASE RECORD ATTACHMENT 4 (DQA RESULTS)

CENTRAL PENINSULA SURVEY UNIT 9530-0001 RELEASE RECORD ATTACHMENT 4A (PRELIMINARY DATA REVIEW)

PRELIMINARY DATA REVIEW FORM Survey Unit:

Survey Unit Name:

Classification :

Survey Media:

Type of Survey :

Type of Measurement:

lumber of Measurements :

9530-0001 Central Peninsula 2

Soil Final Status Survey Radionuclide Specific 15 BASIC STATISTICAL QUANTITIES Cs-137 Target Level (pCi/g) :

5.38E+00 Minimum Value:

4.15E-02 Maximum Value:

2.59E-01 Mean:

1.09E-01 Median:

1.21E-01 Standard Deviation :

5.40E-02 Sample Identification 9530-0001-001F 9530-0001-002F 9530-0001-003F 9530-0001-004F 9530-0001-005F 9530-0001-006F 9530-0001-007F 9530-0001-008F 9530-0001-009F 9530-0001-O0OF 9530-0001-01iF 9530-0001-012F 9530-0001-013F 9530-0001-014F 9530-0001-015F Reported Results Cs-137 Concentration (pCi/g) 1.30E-01 1.27E-01 2.59E-01 1.31 E-01 4.85E-02 1.21 E-01 1.34E-01 1.33E-01 6.41 E-02 1.34E-01 1.06E-01 8.50E-02 7.29E-02 5.47E-02 4.15E-02 Detect?

+

+

+

+

+

+

+

+

+

+

+

+

+

+

Fraction of Target Level 0.024 0.024 0.048 0.024 0.009 0.022 0.025 0.025 0.012 0.025 0.020 0.016 0.014 0.010 0.008 J

S Ce-.

SqkD ied6 1 f

/o // I 1 of 1

CENTRAL PENINSULA SURVEY UNIT 9530-0001 RELEASE RECORD ATTACHMENT 4B (GRAPHICAL REPRESENTATION OF DATA)

FREQUENCY PLOT FOR CESIUM-137 Survey Unit:

Survey Unit Name:

Mean:

9530-0001 Central Peninsula 1.09E-01 pCi/g Frequency Plot For Cs-137 10 8

"6 2

4.15E-02 9.33E-02 1.45E-01 1.97E-01 2.49E-01 3.01E-01 Upper End Value (pCi/g)

Upper End Observation Observation Value Frequency Frequency 4.15E-02 1

7%

9.33E-02 5

33%

1.45E-01 8

53%

1.97E-01 0

0%

2.49E-01 0

0%

3.01E-01 1

7%

Total:

15 100%

J.-/7o3Id ReviewIof 1 of 1

QUANTILE PLOT FOR CESIUM-137 Survey-Unit:

9530-0001 Survey Unit Name: Central Peninsula Mean:

1.09E-01 pCi/g Quantile Plot For Cs-137 3.OOE-01 2.50E-01 O 2.OOE-01 0

1.50E 1.OQE-01 0

5.00E-02 0.00E+00 0

20 40 60 80 100 Percentage Cs-137 Rank Percentage 4.15E-02 1

3%

4.85E-02 2

10%

5.47E-02 3

17%

6.41E-02 4

23%

7.29E-02 5

30%

8.50E-02 6

37%

1.06E-01 7

43%

1.21E-01 8

50%

1.27E-01 9

57%

1.30E-01 10 63%

1.31E-01 11 70%

1.33E-01 12 77%

1.34E-01 13 83%

1.34E-01 14 90%

2.59E-01 15 97%

(, eý7-4: 2pef-Z'fA f 114, 1 SI

]

/

S1

/

CENTRAL PENINSULA SURVEY UNIT 9530-0001 RELEASE RECORD ATTACHMENT 4C (SIGN TEST)

Connecticut Yankee Decommissioning Project Health Physics Procedure GPP-GGGR-R5121-001 Attachment A, Rev CY-001 MAJOR Sign Test Calculation Sheet For A Single Radionuclide or Gross Activity Measurements Survey Area Number: 9530 Survey Unit Number: 0001 Survey Area Name: Central Peninsula WPIR#: 2006-0038 Classification: 2 Type I (ax error): 0.05 (N): 15 Radionuclide: Cs-137 DCGL: 5.38 Results (pCi/g)

DCGL - Results Sign 1.30E-01 5.25E+00 1

1.27E-01 5.25E+00 1

2.59E-01 5.12E+00 1

1.31E-01 5.25E+00 1

4.85E-02 5.33E+00 1

1.21E-01 5.26E+00 1

1.34E-01 5.25E+00 1

1.33E-01 5.25E+00 1

6.41E-02 5.32E+00 1

1.34E-01 5.25E+00 1

1.06E-01 5.27E+00 1

8.50E-02 5.30E+00 1

7.29E-02 5.3 1E+00 1

5.47E-02 5.33E+00 1

4.15E-02 5.34E+00 1

1*

+

4-

.1.

1 1-4 4-Number of positive differences (S+): 15 Critical Value: I11 Performed by:

se*.6,te Independent Review by.

Survey Unit Meets Acceptance Criterion Date:

Ji/'11-1cl1' Date:

t~ z'3)c*(,

Page 1 of I

CENTRAL PENINSULA SURVEY UNIT 9530-0001 RELEASE RECORD ATTACHMENT 4D (QC SPLIT RESULTS)

Health Physics Procedure 24265-000-GPP-GGGR-R5124-000-Rev.CY-000 Attachment A HelhPysisPoeue22500GPGG-5I2-0-e.Y00Atcmn Split Sample Assessment Form Survey Area#: 9530 Survey Unit #: 0001 Survey Unit name: Central Peninsula Sample Plan or WPIR#: 2005-0038 SML#: 9530-0001-006 Sample

Description:

Comparison of split samples collected from sample measurement location #6 and analyzed using gamma spectroscopy by off-site Vendor Laboratory. The standard sample was 9530-0001-006F, the comparison sample was 9530-0001-006FS.

STANDARD COMPARISON Radionuclide Activity Standard Resolution Agreement Activity Standard Comparison Acceptable Value Error Range Value Error Ratio (Y/N)

Cs-137 1.21E-1 1.38E-2 9

0.6-1.66 1.24E-1 2.27E-2 1.02 Y

Comments/Corrective Actions: N/A Table is provided to show acceptance criteria used to assess split samples.

Resolution Agreement Range 4-7 0.5-2.0 8-15 0.6-1.66 16-50 0,75 - 1.33 51 -200 0,80 - 1.25

>200 0.85-1.18

.- /

j Page 1 of I

Health Physics Procedure 24265-000-GPP-GGGR-R5124-000-Rev.CY-000 Attachment A HelhPyisPoeue22500GPGG-5I2-0-e.Y00Atcmn Split Sample Assessment Form Survey Area#: 9530 Survey Unit #: 0001 Survey Unit name: Central Peninsula Sample Plan or WPIR#: 2005-0038 SML#: 9530-0001-014 Sample

Description:

Comparison of split samples collected from sample measurement location #14 and analyzed using gamma spectroscopy by off-site Vendor Laboratory. The standard sample was 9530-0001-014F, the comparison sample was 9530-0001-014FS.

STANDARD COMPARISON Radionuclide Activity Standard Resolution Agreement Activity Standard Comparison Acceptable Value Error Range Value Error Ratio (YIN)

K-40 1.25E1 6.55E-1 191 0.8-1.25 1.22E1I 5.40E-1 0.98 Y

Comments/Corrective Actions: Cs-137 was not detected in sufficient quantities to evaluate in accordance with procedure Table is provided to show acceptance criteria used to assess split samples.

Resolution 4-7 8-15 16 -50 51 -200

>200 Agreement Range 0.5 -2.0 0.6 - 1.66 0.75 - 1.33 0.80 - 1.25 0.85-1.18 Performed By:

U, J

Page 1 of 1

CENTRAL PENINSULA SURVEY UNIT 9530-0001 RELEASE RECORD ATTACHMENT 4E (COMPASS DQA WITH POWER CURVE)

DQA Surface Soil Report Assessment Summary Site:

Planner(s):

Survey Unit Name:

Report Number:

Survey Unit Samples:

Reference Area Samples:

Test Performed:

Judgmental Samples:

Assessment

Conclusion:

9530-0001 FSS McCarthy 0__*

Central Peninsula 1

15 0

Sign Test Result:

Not Performed 0

EMC Result:

Not Performed Reject Null Hypothesis (Survey Unit PASSES)

Retrospective Power Curve 0.9

_- 0.8 0.7 it 0.6

  • 0.5 0.4 0.3 A- 0.2 0.1 o

!zz4-_

0 1

2 3

4 5

Soil Coxcentration (Cilg), includi,'g backgrownd Prospective Power U

1-beta Actual Power LBGR i Estimated Power DCGL Retrospective Power 6

COMPASS v0.0.0 1011912006 Page1I

~DQA Surface Soil Report Survey Unit Data NOTE:

Type = "S" indicates survey unit sample.

Type = "R" indicates reference area sample.

Sample Number 9530-0001-001 F 9530-0001-002F 9530-0001-003F 9530-0001-004F 9530-0001-005F 9530-0001-006F 9530-0001-007F 9530-0001-008F 9530-0001-009F 9530-0001 -01 OF 9530-0001-011 F 9530-0001-012F 9530-0001-013F 9530-0001-014F 9530-0001-015F Type S

S S

S S

S S

S S

S S

S S

S S

Cs-1 37 (pC i/g) 0.13 0.13 0.26 0.13 0.05 0.12 0.13 0.13 0.06 0.13 0.11 0.08 0.07 0.05 0.04 Basic Statistical Quantities Summary Statistic Survey Unit

Background

DQO Results Sample Number Mean (pCi/g)

Median (pCi/g)

Std Dev (pCi/g)

High Value (pCi/g)

Low Value (pCi/g) 15 0.11 0.12 0.05 0.26 0.04 N/A N/A N/A N/A N/A N/A N=15 0.16 N/A 0.0916 N/A N/A COMPASS v1.0.0 10/19/2006 Page 2