CYAPCO FINAL STATUS SURVEY RELEASE RECORD CENTRAL PENINSULA SURVEY UNIT 9530-0003 jlck f~24A Prepared By:
Reviewed B A
Approved By:
T)[.
Technical Support Manager Date: /*d-rlye Date("
Date:_____
Revision 0
CENTRAL PENINSULA SURVEY UNIT 9530-0003 RELEASE RECORD TABLE OF CONTENTS
- 1.
SURVEY UNIT DESCRIPTION......................................................
3
- 2.
CLASSIFICATION BASIS..........................................
3
- 3.
DATA QUALITY OBJECTIVES (DQO)..........................................
5
- 4.
SURV EY D ESIGN.............................................................................
8
- 5.
SURVEY IMPLEMENTATION.......................................................
11
- 6.
SURVEY RESULTS.........................................................................
12
- 7.
QUALITY CONTROL....................................................................
15
- 8.
INVESTIGATIONS AND RESULTS..............................................
15
- 9.
REMEDIATION AND RESULTS...................................................
15
- 10. CHANGES FROM THE FINAL STATUS SURVEY PLAN......
15
- 11. DATA QUALITY ASSESSMENT (DQA)......................................
16
- 12. A N O M A LIE S....................................................................................
16
- 13. C O N C LU SIO N..................................................................................
16
17 14.1 Attachment 1 - Figures (6 pages including cover) 14.2 Attachment 2 - Scan Results (3 pages including cover) 14.3 Attachment 3 - Laboratory Data (78 pages including cover) 14.4 Attachment 4-DQA Results (14 pages including covers)
TOTAL 118 Revision 0
CENTRAL PENINSULA SURVEY UNIT 9530-0003 RELEASE RECORD
- 1.
SURVEY UNIT DESCRIPTION Survey Unit 9530-0003 (Central Peninsula) is designated as Final Status Survey (FSS) Class 2 and consists of 6,438 m2 (1.6 acres) of uninhabited open land located approximately 3,160 feet from the reference coordinate system benchmark used at Haddam Neck Plant (HNP) (see Attachment 1). The survey unit is bounded by land Survey Unit 9530-0004. The survey unit is relatively level open space in the middle of the peninsula.
The restoration of the peninsula for FSS has removed most surface interference in the survey unit.
The reference coordinates associated with this survey unit are E015 through E022 by S I10 through S 116 (refer to License Termination Plan (LTP) Section 5.4.4).
The reference coordinates provide the maximum dimensions of a rectangle containing this survey unit. Some areas contained in this rectangle may not be part of this survey unit.
The boundary of the survey unit was defined using a Global Positioning System (GPS) based on the Connecticut State Plane System North American Datum (NAD) 1927.
- 2.
CLASSIFICATION BASIS The survey unit was classified in accordance with Procedure RPM 5.1-10, "Survey Unit Classification. " The historical information, scoping analyses and characterization results provided sufficient data to designate Survey Unit 9530-0003 as Class 2 in September 2006.
The "Classification Basis Summary" conducted for Survey Unit 9530-0003 consisted of:
a) A review of the 10CFR50.75 (g) (1) database, b) A review of the "Initial Characterization Report" and the "Historic Site Assessment Supplement,"
c) Historic and current survey records review, d) Visual inspections and a "walkdown."
A review of the 10CFR50.75(g)(1) database report identified two documents associated with this survey unit.
a) Northeast Utilities Radiological Assessment Branch memo NE-86-RA-1142: Relates to dredging of two areas of the Discharge Canal to support the Low Pressure Turbine replacement project. Spoils from dredging were relocated to this survey unit and adjacent survey unit 9530-0002.
b) Condition Report (CR) 98-0049: Documents that dredge spoils from the Discharge Canal contained radioactive material in 1987.
A review of the "Initial and Supplemental Characterization Reports" as well as the previous "Classification Basis Summaries" provided no additional information pertinent to classification.
Revision 0 3
CENTRAL PENINSULA SURVEY UNIT 9530-0003 RELEASE RECORD The survey unit had undergone FSS in the fall of 2004 and release records documenting the satisfactory completion of the FSS objectives were in preparation.
In 2006, utilities were being removed as part of the decommissioning effort on the Upper Peninsula.
Construction debris including Asbestos Containing Material (ACM) was identified and remediated. In addition to the ACM, several objects were also identified that had detectable radioactivity. Two pieces of angle iron were located in a water utility trench in adjacent Survey Unit 9530-0004. Most of the work involved two areas adjacent to Survey Unit 9530-0003.
Based on the potential to change the final radiological status of the survey unit, another FSS was considered prudent to define the as-left radiological condition.
Soil samples were collected in 2006 to establish the radiological condition of the surface and subsurface area following removal of soil. Cs-137 was the only gamma emitting radionuclide reported in concentrations with the potential for exceeding the screening criteria. Therefore, the previous FSS data and statistical parameters were used for the survey design. Statistical quantities from the previous FSS survey are provided in Table 1.
Table 1 - Bas;ic Statistical Quantities for Cs-f37from= the prevno FS uAey Minimum Observed Concentration (pCi/g):
1.07E-01 Maximum Observed Concentration (pCi/g):
4.15E-01 Mean (pCi/g):
2.65E-01 Median (pCi/g):
2.64E-01 Standard Deviation (pCi/g):
7.13E-02 The FSS Engineer performed a visual inspection and walk-down during September 2006 to assess the physical condition of the survey unit, evaluate access points and travel paths and identify potentially hazardous conditions.
This survey area is affected by existing groundwater (reference CY memo ISC 06-024) which will be a source of dose from residual radioactivity, as discussed in Section 3 under the Data Quality Objectives.
Based upon the historical information and the results of radiological surveys performed during characterization, it was concluded that there was a low probability for residual radioactivity to be present in this survey unit in concentrations greater than the Operational Derived Concentration Guideline Levels (DCGLs) justifying a final survey unit classification of Class 2 (refer to Section 3).
Revision 0 4
Revision 0 4
CENTRAL PENINSULA SURVEY UNIT 9530-0003 RELEASE RECORD
- 3.
DATA QUALITY OBJECTIVES (DQO)
FSS design and planning used the Data Quality Objective (DQO) process as described by the LTP, Procedure RPM 5.1-11, "Preparation of Final Status Survey Plan, " and the "Multi-Agency Radiation Survey and Site Investigation Manual" (MARSSIM). A summary of the main features of the DQO process are provided herein.
The DQO process incorporated hypothesis testing and probabilistic sampling distributions to control decision errors during data analysis. Hypothesis testing is a process based on the scientific method that compares a baseline condition to an alternate condition. The baseline condition is technically known as the null hypothesis. Hypothesis testing rests on the premise that the null hypothesis is true and that sufficient evidence must be provided for rejection. In designing the survey plan, the underlying assumption, or null hypothesis was that residual activity in the survey unit exceeded the release criteria. Rejection of the null hypothesis would indicate that residual activity within the survey unit does not exceed the release criteria. Therefore, the survey unit does satisfy the primary objective of the FSS plan.
The primary objective of the FSS plan was to demonstrate that the level of residual radioactivity in Survey Unit 9530-0003 did not exceed the release criteria specified in the LTP and that the potential dose from residual radioactivity is As Low As Reasonably Achievable (ALARA).
A fundamental precursor to survey design is to establish a relationship between the release criteria and some measurable quantity.
This is done through the development of DCGLs. The DCGLs represent average levels of radioactivity above background levels and are presented in terms of surface or mass activity concentrations. Chapter 6 of the LTP describes in detail the modeling used to develop the DCGLs for soil (called Base Case Soil DCGL), existing groundwater radioactivity and future groundwater radioactivity that will be contributed by building basements and footings.
The DCGLs presented in Chapter 6 of the LTP were developed for exposures from three (3) components, that is, residual radioactivity in soil, existing groundwater radioactivity, and future groundwater radioactivity from the burial of concrete foundations or footings from site buildings containing residual radioactivity.
Equation 1 shows the mathematical relationship between the three (3) components and the total dose.
Revision 0 5
Revision 0 5
CENTRAL PENINSULA SURVEY UNIT 9530-0003 RELEASE RECORD Equation 1 HTotal Hsoil +/- HExistingGW + HFutureGW The total dose under the LTP criteria is twenty-five (25) mremlyr TEDE from all three (3) components.
The allowable total dose under the Connecticut Department of Environmental Protection (CTDEP) radiological remediation standard for CY is nineteen (19) mrem/yr TEDE. To satisfy both the LTP and CY CTDEP criteria, the dose from soil must be reduced when using the existing and future groundwater dose Values discussed above.
This survey area is affected by existing groundwater (reference CY memo ISC 06-024).
Therefore, the dose contribution from existing groundwater is bounded by two (2) mrem/yr TEDE.
This survey unit is not considered impacted by future groundwater radioactive contamination, as there are no buried concrete foundations or footings containing residual radioactive material within the groundwater saturated zone in the area (reference CY memo ISC 06-024). The dose contribution from future groundwater, the third dose component is, therefore, zero (0) mrem/yr TEDE.
Equation 2 19 mrem/yrTotal = 17 mrem/yrsoil + 2 mrem/yrExisting GW+ 0 mrem/yrFutureGW The allowable dose for soil in this survey unit is seventeen (17) mrem/yr TEDE as shown by Equation 2 above.
The concentration of residual radioactivity resulting in seventeen (17) mrem/yr TEDE is designated as the Operational DCGL, and has been established for the radionuclides of concern as provided in Table 2.
Revision 0 6
CENTRAL PENINSULA SURVEY UNIT 9530-0003 RELEASE RECORD fTable 2 - Radionu~clide Specific Banse Case Soil DCGL, Operaitional DC(GLs dBae
(
C*tse Soil peritionA DCGL Required MDC H-3 4.12E+02 2.80E+02 1.65E+O1 I C-14 5.66E+00 3.85E+00 2.26E-01 Mn-54 1.74E+01 1.18E+01 6.96E-0I Fe-55 2.74E+04 1.86E+04 1.1 OE+03 Co-60 3.81E+00 2.59E+00 1.52E-01 Ni-63 7.23E+02 4.92E+02 2.89E+O1 Sr-90 1.55E+00 1.05E+00 6.20E-02 Nb-94 7.12E+00 4.84E+00 2.85E-01 Tc-99 1.26E+01 8.57E+00 5.04E-01 Ag-108m 7.14E+00 4.86E+00 2.86E-01 Cs-134 4.67E+00 3.18E+00 1.87E-01 Cs-137 7.91E+00 5.38E+00 3.16E-0 I Eu-152 1.01E+01 6.87E+00 4.04E-01 Eu-154 9.29E+00 6.32E+00 3.72E-0I Eu-155 3.92E+02 2.67E+02 1.57E+01 Pu-238 2.96E+01 2.01E+O1
- 1. 18E+00 Pu-239/240 2.67E+01 1.82E+01 1.07E+00 Pu-241 8.70E+02 5.92E+02 3.48E+O 1 Am-241 (5) 2.58E+01 1.75E+01 1.03E+00 Cm-243/244 2.90E+0 1 1.74E+01
- 1. 1 6E+00 (1) Bold indicates those radionuclides considered to be Hard-to-Detect (HTD)
(2) The Base Case Soil DCGLs for soil are specified by the LTP in Chapter 6 and are equivalent to 25 mrem/yr TEDE (3) The Operational DCGL is equivalent to 17 mrem/yr TEDE (4) The required MDC is equivalent to I mrem/yr TEDE (5) Americium-241 can be analyzed by gamma and alpha spectroscopy and is considered to be Easy to Detect (ETD); the preferred result is the alpha spectroscopy's when both analyses are performed Another important facet of the DQO process is to identify the radionuclides of concern and determine the concentration variability.
Soil samples were collected in 2006 to establish the radiological condition of the surface and subsurface area following removal of soil.
Cs-137 was the only gamma emitting radionuclide reported in concentrations with the potential for exceeding the screening criteria.
The previous FSS data and statistical parameters were used for the survey design and are provided in Table 1.
Revision 0 7
CENTRAL PENINSULA SURVEY UNIT 9530-0003 RELEASE RECORD Instrument DQOs included a verification of the ability of the survey instrument to detect the radiation(s) of interest relative to the DCGL. Survey instrument response checks were required prior to issue and after the instrument had been used. Control and accountability of survey instruments was required to assure the quality and prevent the loss of data.
As part of the DQOs applied to laboratory processes, analysis results were reported as actual calculated results. Results reported as less than Minimum Detectable Concentration (MDC) were not accepted for FSS. Sample report summaries included unique sample identification, analytical
- method, radionuclide, result, and uncertainty to two (2) standard deviations, laboratory data qualifiers, units, and the required and observed MDC.
- 4.
SURVEY DESIGN The level of effort associated with planning a survey is based on the complexity of the survey and nature of the hazards. Guidance for preparing FSS plans is provided in Procedure RPM 5.1-11, "Preparation of Final Status Survey Plans".
The FSS plan uses an integrated sample design that combines scanning surveys and sampling which can be either random or biased.
The DQO process determined that Cs-137 would be the radionuclide of concern in survey unit 9530-0003 (refer to Section 3). Other radionuclides identified during this FSS would be evaluated to ensure adequate survey design.
Surrogate DCGLs were not required for this survey unit based the previous FSS of this survey unit and via screening under LTP Section 5.4.7.2, "Gross Activity DCGLs".
Radionuclide screening or de-selection is a process where an individual radionuclide or aggregates may be considered insignificant and eliminated from the FSS. The criteria for de-selection are concentrations less than 5% for individual radionuclides and less than 10% for aggregates.
The Elevated Measurement Comparison (EMC) did not apply to this survey unit since it is a Class 2 area and discrete, elevated areas of contamination were not expected.
The Sign Test was selected as the non-parametric statistical test. The use of the Sign Test did not require the selection or use of a background reference area, which simplified survey design and implementation.
This approach was conservative since it included background Cs-137 as part of the sample set.
The number of soil samples for FSS was determined in accordance with Procedure RPM 5.1-12, "Determination of the Number of Surface Samples for Final Status Survey." The Lower Bound of the Gray Region (LBGR) was set in accordance with Procedure RPM 5.1-11 to 5.24 to maintain the relative shift (A/o) in the range of 1 and 3. The resulting Adjusted Relative Shift was 2.0. A Prospective Power Curve was generated using COMPASS, a software package developed under the sponsorship of the United States Nuclear Regulatory Commission (USNRC) for implementation of the MARSSIM in support of the Revision 0 8
Revision 0 8
CENTRAL PENINSULA SURVEY UNIT 9530-0003 RELEASE RECORD decommissioning license termination rule (10 CFR 20, Subpart E). The result of the COMPASS computer run showed adequate power for the survey design.
The survey design specified fifteen (15) surface soil samples for non-parametric statistical testing and one (1) sample at biased locations.
The grid pattern and locations of the soil samples were determined using Visual Sample Plan (VSP) in accordance with Procedure RPM 5.1-14, "Identifying, and Marking Surface Sample Locations for Final Status Survey."
Visual Sample Plan was created by Pacific Northwest National Laboratory (PNNL) for the United States Department of Energy. A systematic triangular grid pattern with a random starting point was selected for sample design, which is appropriate for a Class 2 area.
Judgmental sampling was included as a feature of this survey design to account for any anomalies potentially identified in the field.
Sample locations were identified using AutoCAD-LT, a commercially available plotting software package with coordinates consistent with the Connecticut State Plane System. These coordinates were integrated with a GPS to locate sample locations in the field. Sample Measurement Locations for the design are listed with the GPS coordinates in Table 3.
Ta~ble 3 -Sample Measurement Locations vwithi Associated GPS Coordinates De'signatioii Northing Eas~ting 9530-0003-001F 235444.17 671142.01 9530-0003-002F 235444.17 671214.42 9530-0003-003F 235381.47 671105.81 9530-0003-004F 235381.47 671178.21 9530-0003-005F 235381.47 671250.62 9530-0003-006F 235381.47 671323.03 9530-0003-007F 235318.76 671069.60 9530-0003-008F 235318.76 671142.01 9530-0003-009F 235318.76 671214.42 9530-0003-01,OF 235318.76 671286.82 9530-0003-OIF 235256.05 671105.81 9530-0003-012F 235256.05 671178.21 9530-0003-013F 235256.05 671250.62 9530-0003-014F 235193.35 671142.01 9530-0003-015F 235193.35 671214.42 9530-0003-016F 235221.79 671062.34 Procedure RPM 5.1-11 specifies that 5% of the samples are required to be selected for HTD analysis. Two (2) soil samples, or about 10% of the number of samples that would be used for non-parametric statistical testing were Revision 0 9
Revision 0 9
CENTRAL PENINSULA SURVEY UNIT 9530-0003 RELEASE RECORD randomly selected for HTD radionuclide analysis using the Microsoft Excel "RANDBETWEEN" function. Each sample was sent off-site for a full suite analysis of the HTD radionuclides specified in the LTP, Table 2-12, "Radionuclides Potentially Present at Haddam Neck Plant" and as provided in Table 2.
The implementation of quality control measures as referenced by Procedure RPM 5.1-24, "Split Sample Assessment for Final Status Survey," included the collection of two (2) soil samples for "split sample" analysis by the off-site laboratory. These locations were selected randomly using the Microsoft Excel "RANDBETWEEN" function. The number of quality control soil samples was about 10% of fifteen (15) samples.
The LTP specifies that scanning will be performed along with a combination of systematic and judgmental measurements (samples) for a Class 2 land area and should cover between 10% to 100% of the area.
The fraction of scanning coverage was determined during the DQO process with the total amount and location(s) based on the likelihood of finding elevated activity during FSS.
Based on the historical site assessment, the characterization data available, and the use of the survey unit to store spoils from remediation, it was determined that scanning was required in three (3) separate areas. The total surface area to be scanned was approximately 12% of the survey unit. A map of the scan grid locations is provided in Attachment 1.
For this Class 2 survey unit, the "Investigation Level" for area scanning and soil sample measurement results are those levels specified in LTP, Table 5-8. Table 4 provides a synopsis of the survey design.
Nurvey Unit Land Area 6,4-3 m"t based on AutoCAV-LI Type I and Type 2 errors were 16 0.05, sigma was 0.071 pCi/g, Number of Measurements (15 systematic grid) the LBGR was adjusted to 5.24 (1 biased) to maintain Relative Shift in the range of 1 and 3 Grid Spacing 22.3 m Based on triangular grid Administratively set to achieve Operational DCGL 5.38 pCi/g Cs-137 17 mrem/yr TEDE (1)
The Operational DCGL meets Soil Investigation Level 5.38 pCi/g Cs-137 the LTP criteria for a Class 2 1
1 survey unit Revision 0 10 Revision 0 10
CENTRAL PENINSULA SURVEY UNIT 9530-0003 RELEASE RECORD Scan Survey Area Coverage Approximately 12%
of the area i ne L I i" requires - I 'ro area coverage for Class 2 survey units Detectable over Administratively set to achieve Scan Investigation Level background 17 mrem/yr TEDE (1 (1) The allowable dose for soil in this survey unit is 17 mrem/yr TEDE as the bounding dose from existing and future groundwater has been established based on field data (reference CY memo ISC 06-024)
- 5.
SURVEY IMPLEMENTATION Final status survey field activities were conducted under Work Plan and Inspection Record (WP&IR) 2006-0038.
The WP&IR package included a detailed FSS plan, job safety analysis, job planning checklist and related procedures for reference.
Daily briefings were conducted to discuss the expectations for job performance and the safety aspects of the survey. The "Daily Survey Journal" was used to document field activities and other information pertaining to the FSS.
Two (2) scan areas were established that constituted approximately 12% of the surface area of Survey Unit 9530-0003.
Grid lines, one meter wide, were painted on the ground of the scan area. A background survey was performed around the survey unit and it was determined that, using an Eberline E-600 with a SPA-3 sodium iodide detector, background ranged from 6,280 counts per minute (cpm) up to 8,220 cpm.
The scan areas were established and scanned for elevated readings (see for all scan results). Scanning was performed with an Eberline E-600 using a SPA-3 sodium iodide detector. The E-600 was operated in the rate-meter mode and used with audio response. The probe was positioned as close to the ground as possible and was moved at a scan speed of about 0.5 meters per second. Approximately 12% of the survey unit was scanned.
Measurement locations were identified in North American Datum (NAD) 1927 coordinates using GPS coordinates; sample locations were identified and marked with a surveyor's flag or paint for identification.
At each sample location, a one (1) meter radius around the sample flag or paint mark was scanned for elevated radiation levels.
Sixteen (16) surface soil samples were collected and packaged in accordance with Haddam Neck Plant (HNP) Procedure RPM 5.1-3, "Collection of Sample Media for Final Status Survey" and FSS design.
Samples were controlled, transported, stored, and transferred to the off-site laboratory using Chain-of-Custody (COC) protocol in accordance with Procedure RPM 5.1-5, "Chain of Custody for Final Status Survey Samples."
Revision 0 I1I Revision 0 11
CENTRAL PENINSULA SURVEY UNIT 9530-0003 RELEASE RECORD Two (2) samples (9530-0003-013F and 9530-0003-014F) were randomly selected for HTD radionuclide analysis.
The implementation of survey specific quality control measures included the collection of two (2) samples (9530-0003-004F and 9530-0003-006F) for "split sample" analysis.
- 6.
SURVEY RESULTS All field survey activities were conducted between September 12, 2006 and September 13, 2006.
The sample locations identified in the FSS plan were scanned over approximately a one (1) meter radius for elevated radiation levels.
Table 5 provides an overview of the scan results for sample measurement locations.
Scan results are provided in Attachment 2.
~Table 5-, -Scan Results for Sample Measurement L~ocations mpie>>.
Highest Logge. d Action Level ()
Measureluent
<+>>Reading Aclion LeI (2)
Location
'(kcpm) 1 7.55 8.57 NO 2
7.26 8.87 NO 3
7.60 8.66 NO 4
7.57 8.77 NO 5
8.28 9.45 NO 6
6.53 7.59 NO 7
7.50 7.89 NO 8
7.69 8.51 NO 9
7.08 8.62 NO 10 7.72 9.05 NO 11 7.49 7.89 NO 12 7.46 8.59 NO 13 7.28 8.22 NO 14 6.38 8.37 NO 15 8.60 9.02 NO 16 5.87 7.34 NO (1) The action level is based on a measurement above ambient background in accordance with the FSS plan Revision 0 12
CENTRAL PENINSULA SURVEY UNIT 9530-0003 RELEASE RECORD Table 5 r
-uScan Results for Sample Measurement Locationsth Sani~Ie HighstLgged'~ Action Level ~
2 Measuremient" Readfn-,(kcm)
Action Level LAoc'at ion
~
(kcji1),
(2) The FSS plan requires movement of the sample measurement location to the area within the 1 meter radius yielding the response above the action level The scan areas, that comprised approximately 12% of the total surface area for the survey unit, were scanned for elevated radiation levels. The areas were scanned in accordance with the FSS plan on September 12, 2006 and September 13, 2006. No elevated measurement locations were identified during scanning.
Table 6 provides an overview of the scan area survey. Scan results are provided in Attachment 2.
Table 6 - Scan Area Results A rea "Reading (kcpm)
Red~g~
Sample 1
8.35 9.40 elevated areas None identified None - no 2
8.83 9.16 elevated areas None identified (1) The action level is based on a measurement above ambient background (2) ER is an abbreviation associated with the barcodes used in the field where ER stands for Elevated Reading The off-site laboratory employed for the radiological analyses of samples was General Engineering Laboratories, LLC. The laboratory analyzed the fifteen (15) samples collected for non-parametric statistical testing, the associated field splits, and the one (1) biased sample using gamma spectroscopy.
Gamma spectroscopy analysis was performed to the required MDCs.
Gamma spectroscopy results identified some radionuclides meeting the accepted criteria for detection (i.e., a result greater than two standard deviations uncertainty).
However, Cs-137 was the only radionuclide reported in concentrations exceeding the de-selection criteria.
Cs-137 was identified in all fifteen (15) samples collected for non-parametric statistical testing. Cs-137 was the primary radionuclide confirming the DQOs.
The mean of the gamma spectroscopic analysis results for the sample population indicated that Cs-137 was present at levels lower than the concentrations of Cs-137 found in soil at off-site locations within the vicinity of the HNP as presented in the Health Physics TSD BCY-HP-0063.
Revision 0 13 Revision 0 13
CENTRAL PENINSULA SURVEY UNIT 9530-0003 RELEASE RECORD A summary of the fifteen (15) samples collected for non-parametric statistical testing results is provided in Table 7.
9530-0003-00 1F 1.41E-01 0.026 9530-0003-002F 3.26E-01 0.061 9530-0003-003F 2.83E-01 0.053 9530-0003-004F 3.09E-01 0.057 9530-0003-005F 4.87E-01 0.091 9530-0003-006F 9.57E-02 0.018 9530-0003-007F 5.70E-02 0.011 9530-0003-008F 2.89E-01 0.054 9530-0003-009F 3.95E-01 0.073 9530-0003-OIOF 2.87E-01 0.053 9530-0003-01 F 2.27E-01 0.042 9530-0003-012F 3.19E-01 0.059 9530-0003-013F 2.27E-01 0.042 9530-0003-014F 1.17E-01 0.022 9530-0003-015F 1.63E-01 0.030 (1) The Operational DCGL from Table 2 is 5.38 pCi/g for Cs-137 to achieve 17 mrem/yr TEDE The off-site laboratory also processed two (2) samples for HTD analysis as required by the sample plan.
The requested analyses included alpha spectroscopy, gas proportional counting, and liquid scintillation depending on the radionuclide and the measurement method. All analyses met the required MDC.
As previously stated in Section 4 of this report, the criteria for de-selection of a radionuclide is a concentration that is less than 5% of the Operational DCGL for individual radionuclides and less than 10% of the Operational DCGLs for aggregates. Tc-99 was the only HTD, which by analysis, met the criteria for detection (i.e., a result greater than two standard deviations uncertainty). The highest result for Tc-99 was at 2.9% of the Operational DCGL.
Revision 0 14
CENTRAL PENINSULA SURVEY UNIT 9530-0003 RELEASE RECORD 9530-0003-014F 2.74E-01 0.029 (1) The Operational DCGL from Table 2 is 8.57 pCi/g for Tc-99 to achieve 17 mrem/yr TEDE One (1) biased sample was collected at a location selected by FSS Supervision based on professional judgment and observation. Gamma spectroscopy analysis was performed by the off-site laboratory to the required MDC.
Table1 ~-Judgmental or Biased Sample Results Sample Number-C13Frcinoth pCi/.
. ii:
Operational DCGL) 9530-0003-016F 9.17E-02 0.017 (1) The Operational DCGL from Table 2 is 5.38 pCi/g for Cs-137 to achieve 17 mrem/yr TEDE
- 7.
QUALITY CONTROL The off-site laboratory processed the split samples and performed gamma spectroscopy analysis.
Ten percent (10%) of the samples were selected for analysis, which exceeds the 5% minimum required by the LTP. The data were evaluated using USNRC acceptance criteria specified in Inspection Procedure 84750 as detailed in HNP Procedure RPM 5.1-24, "Split Sample Assessment for Final Status Survey." There was acceptable agreement between field split results for Cs-137 at both locations.
The sample analysis vendor, General Engineering Laboratories, LLC, maintains quality control and quality assurance plans as part of normal operation. Refer to for data and data quality analysis results.
- 8.
INVESTIGATIONS AND RESULTS No confirmatory samples were necessary.
- 9.
REMEDIATION AND RESULTS Historically, no radiological remedial action as described by MARSSIM Section 5.4 was performed in this survey unit prior to or as a result of the FSS. Health Physics TSD BCY-HP-0078, "ALARA Evaluation of Soil Remediation in Support of Final Status Survey, " determined that remediation beyond that required to meet the release criteria is unnecessary and that the remaining residual radioactivity in soil was ALARA.
- 10.
CHANGES FROM THE FINAL STATUS SURVEY PLAN No changes were made to the FSS plan.
Revision 0 15 Revision 0 15
CENTRAL PENINSULA SURVEY UNIT 9530-0003 RELEASE RECORD
- 11.
DATA QUALITY ASSESSMENT (DQA)
The DQO sample design and data were reviewed in accordance with Procedure RPM 5.1-23, "Data Quality Assessment, " for completeness and consistency.
The sampling design had adequate power as indicated by the Retrospective Power Curve. The Sign Test was performed on the data and compared to the original assumptions of the DQOs. The evaluation of the Sign Test results demonstrates that the survey unit passes the unrestricted release criteria, thus, the null hypothesis is rejected.
Documentation was complete and legible. Surveys and sample collection were consistent with the DQOs and were sufficient to ensure that the survey unit was properly designated as Class 2.
The preliminary data review consisted of calculating basic statistical quantities (e.g., mean, median, standard deviation). The mean and median values are well below the Operational DCGL. Also, the retrospective power curve shows that a sufficient number of samples were collected to achieve the desired power.
Therefore, the survey unit meets the unrestricted release criteria with adequate power as required by the DQOs.
For Cs-137, the range of the data, about four (4) standard deviations, was not a particularly large variation considering that the levels were essentially at existing environmental levels where such variation is to be expected.
The difference between the mean and median was -30% of the standard deviation which indicates some skewness in the data.
The data was represented graphically through posting plots, a frequency plot, and a quantile plot. The frequency plot indicates positive skewness as confirmed by the calculated skew of 0.17.
All data, assessments, and graphical representations are provided in Attachment 4.
- 12.
ANOMALIES No anomalies were noted.
- 13.
CONCLUSION Survey Unit 9530-0003 has met the final DQOs of the FSS plan. The ALARA criteria for soils as specified in Chapter 4 of the LTP were achieved. Elevated Measurement Comparison and remediation was not required.
Cs-137 was used for statistical testing to determine the adequacy of the survey unit for FSS.
The sample data passed the Sign Test. The null hypothesis was rejected.
The Retrospective Power Curve generated using COMPASS shows adequate power was achieved. The survey unit is properly designated as Class 2.
Revision 0 16 Revision 0 16
CENTRAL PENINSULA SURVEY UNIT 9530-0003 RELEASE RECORD The dose contribution from soil is less than 1 mrem/yr TEDE based on the average concentration of the samples used for non-parametric statistical sampling.
This survey area is affected by existing groundwater (reference CY memo ISC 06-024); therefore the dose contribution from existing groundwater is bounded at two (2) mremlyr TEDE.
This survey unit is not considered impacted by future groundwater radioactive contamination, as there are underground structures, systems or components containing residual radioactive material within the groundwater saturated zone in the area (reference CY memo ISC 06-024); therefore, the dose contribution from future groundwater is zero (0) mrem/yr TEDE.
The average total dose from residual radioactivity in this survey unit, including exposures from the three (3) components as described in Section 3, that is, residual radioactivity in soil, existing groundwater radioactivity, and future groundwater radioactivity from the burial of concrete foundations or footings from site buildings containing residual radioactivity, will not exceed 3 mrem/yr TEDE.
Therefore, Survey Unit 9530-0003 is acceptable for unrestricted release.
- 14.
ATTACHMENTS 14.1 Attachment 1 - Survey Unit Location Map 14.2 Attachment 2 - Scan Results 14.3 Attachment 3 - Laboratory Results 14.4 Attachment 4 - DQA Results Revision 0 17
CENTRAL PENINSULA SURVEY UNIT 9530-0003 RELEASE RECORD ATTACHMENT 1 (FIGURES)
_rwimacffur ArfTR-r Connecticut Yankee Atomic Power Company Y
- Site Map With Reference To Survey Umt 9530-0003
0 30 600 NAVbmwd alh saph~W27t Connecticut Yankee Atomic Power Company Survey Unit 9530-0003 Final Status Survey Design
0 30 60 P=========MFed Connecticut Yankee Atomic Power Company Survey Unit 9530-0003 Final Status Survey Cs-137Posting Plot
0 30 60 Nofte aft Odw Amu& iq=n to
&2hq~
bym B-00 wiE, SPA-3 Ruhd hyfir Tto bbe6fir an. un~dO, Connecticut Yankee Atomic Power Company Survey Unit 9530-0003 Final Steus Survey Scan Areas
2
- WtLaod
ý2-&=mrc No~W 0
30 60 Notes Ralfr to T9& 9 fir Mi Connetdcut Yankee Atomic Power Company Survey Unit 9530-0003 Biased
CENTRAL PENINSULA SURVEY UNIT 9530-0003 RELEASE RECORD ATTACHMENT 2 (SCAN RESULTS)
Survey Release Record Sample Location Scan Results Survey Unit 9530-0003 Sample Name
Background
Action Level Results Above Log Date Log Time E600 S/N Probe S/N (cpm)
(cDm)
AL 9530-03-SL-00-01 -0 7.35E+03 8.57E+03 7.55E+03 9/12/2006 10:40:00 1116 1006 9530-03-SL-00-02-0 7.62E+03 8.87E+03 7.26E+03 9/12/2006 10:46:00 1116 1006 9530-03-SL-00-03-0 7.43E+03 8.66E+03 7.60E+03 9/12/2006 10:51:00 1116 1006 9530-03-SL-00-04-0 7.53E+03 8.77E+03 7.57E+03 9/12/2006 11:01:00 1116 1006 9530-03-SL-00-05-0 8.16E+03 9.45E+03 8.28E+03 9/12/2006 11:05:00 1116 1006 9530-03-SL-00-06-0 6.44E+03 7.59E+03 6.53E+03 9/12/2006 13:04:00 1116 1006 9530-03-SL-00-07-0 6.72E+03 7.89E+03 7.50E+03 9/12/2006 13:31:00 1116 1006 9530-03-SL-00-08-0 7.29E+03 8.51 E+03 7.69E+03 9/12/2006 13:45:00 1116 1006 9530-03-SL-00-09-0 7.39E+03 8.62E+03 7.08E+03 9/12/2006 13:59:00 1116 1006 9530-03-SL-00-10-0 7.79E+03 9.05E+03 7.72E+03 9/12/2006 11:23:00 1116 1006 9530-03-SL-00-11-0 6.72E+03 7.89E+03 7.49E+03 9/12/2006 14:26:00 1116 1006 9530-03-SL-00-12-0 7.36E+03 8.59E+03 7.46E+03 9/12/2006 14:40:00 1116 1006 9530-03-SL-00-13-0 7.02E+03 8.22E+03 7.28E+03 9/12/2006 14:46:00 1116 1006 9530-03-SL-00-14-0 7.16E+03 8.37E+03 6.38E+03 9/12/2006 14:58:00 1116 1006 9530-03-SL-00-15-0 7.76E+03 9.02E+03 8.60E+03 9/12/2006 14:52:00 1116 1006 9530-03-SL-00-16-0 6.21E+03 7.34E+03 5.87E+03 9/12/2006 15:01:00 1116 1006 AL - Action Level
Survey Release Record Scan Area Results Survey Unit 9530-0003 9530-0003 SCAN AREA 1 Sample Name 9530-03-SC-01-01-0 9530-03-SC-01-02-0 9530-03-SC-01-03-0 9530-03-SC-01-04-0 9530-03-SC-01-05-0 9530-03-SC-01-06-0
- 9530-03-SC-01-07-0 9530-03-SC-01-08-0 9530-03-SC-01-09-0 9530-03-SC-01-10-0 9530-03-SC-01-11-0 9530-03-SC-01-12-0
Background
6.63E+03 7.72E+03 6.75E+03 7.75E+03 6.28E+03 7.12E+03 7.22E+03 8.11E+03 7.49E+03 7.94E+03 7.98E+03 7.31 E+03 Action Level lCPM) 7.79E+03 8.97E+03 7.92E+03 9.01E+03 7.41 E+03 8.32E+03 8.43E+03 9.40E+03 8.73E+03 9.21 E+03 9.26E+03 8.53E+03 Results Above Log Date Log Time E600 SIN Probe SIN 6.73E+03 6.67E+03 6.68E+03 6.05E+03 7.16E+03 7.23E+03 7.67E+03 8.35E+03 7.06E+03 7.39E+03 7.21E+03 7.51 E+03 AL 9/12/2006 9/12/2006 9/12/2006 9/12/2006 9/12/2006 9/12/2006 9/12/2006 9/12/2006 9/12/2006 9/12/2006 9/12/2006 9/12/2006 13:30:00 13:35:00 13:38:00 13:42:00 13:50:00 13:54:00 13:59:00 14:04:00 14:09:00 14:16:00 14:19:00 14:24:00 1117 1117 1117 1117 1117 1117 1117 1117 1117 1117 1117 1117 1008 1008 1008 1008 1008 1008 1008 1008 1008 1008 1008 1008 9530-0003 SCAN AREA 2 Sample Name
Background
(C5M) 9530-03-SC-02-02 -0 7.67E+03 9530-03-SC-02-02-0 7.65E+03 9530-03-SC-02-03-0 7.82E+03 9530-03-SC-02-04-0 7.55E+03 9530-03-SC-02-05-0 7.89E+03 9530-03-SC-02-06-0 7.67E+03 9530-03-SC-02-07-0 7.75E+03 9530-03-SC-02-08-0 8.15E+03 9530-03-SC-02-09-0 8.09E+03 9530-03-SC-02-1 0-0 7.94E+03 9530-03-SC 12-0 8.22E+03 9530-03-SC-02-12-0 6.67E+03 Action Level (cpm) 8.92E+03 8.90E+03 9.08E+03 8.79E+03 9.16E+03 8.92E+03 9.01E+03 9.44E+03 9.37E+03 9.21 E+03 9.51 E+03 7.84E+03 Results 8.64E+03 7.95E+03 7.34E+03 8.41 E+03 8.83E+03 7.59E+03 7.36E+03 8.08E+03 7.41 E+03 7.45E+03 7.06E+03 7.31E+03 Above AL Log Date Log Time E600 S/N Probe S/N 9/13/2006 9/13/2006 9/13/2006 9/13/2006 9/13/2006 9/13/2006 9/13/2006 9/13/2006 9/13/2006 9/13/2006 9/13/2006 9/13/2006 13:03:00 13:07:00 13:12:00 13:18:00 13:23:00 13:34:00 13:29:00 13:40:00 13:43:00 13:46:00 1350:00 13:55:00 1116 1116 1116 1116 1116 1116 1116 1116 1116 1116 1116 1116 1006 1006 1006 1006 1006 1006 1006 1006 1006 1006 1006 1006 AL - Action Level
CENTRAL PENINSULA SURVEY UNIT 9530-0003 RELEASE RECORD ATTACHMENT 3 (LABORATORY DATA)
General Narrative 1
CASE NARRATIVE For CONNECTICUT YANKEE RE: Soil PO# 002332 Work Order: 171772 SDG: MSR#06-1255 September 27, 2006 Laboratory Identification:
General Engineering Laboratories, LLC Mailing Address:
P.O. Box 30712 Charleston, South Carolina 29417 Express Mail Delivery and Shipping Address:
2040 Savage Road Charleston, South Carolina 29407 Telephone Number:
(843) 556-8171 Summary:
Sample receipt The sample(s) for this Project arrived at General Engineering Laboratories, LLC, (GEL) in Charleston, South Carolina on September 15, 2006. All sample containers arrived without any visible signs of tampering or breakage. The chain of custody contained the proper documentation and signatures.
The laboratory received the following sample(s):
Sample ID Client Sample ID 171772001 9530-0003-OO1F 171772002 9530-0003-002F 171772003 9530-0003-003F 171772004 9530-0003-004F 171772005 9530-0003-004FS 171772006 9530-0003-005F 171772007 9530-0003-006F 171772008 9530-0003-006FS 171772009 9530-0003-007F GENERAL. ENGINEERING LABORATORIES, LLC a Member of THE GEL GROUP, INC.,
RO. Box 30712 ° Charleston, SC 29417 ° 2040 Savage Road (29407)
Phone (843) 556-8171
- Fax (843) 766-1178 ° www.gel.com
171772010 171772011 171772012 171772013 171772014 171772015 171772016 171772017 171772018 9530-0003-OOSF 9530-0003-009F 9530-0003-01OF 9530-0003-011 F 9530-0003-012F 9530-0003-013F 9530-0003-014F 9530-0003-015F 9530-0003-016F Items of Note:
There are no items of note.
Case Narrative:
Sample analyses were conducted using methodology as outlined in General Engineering Laboratories (GEL) Standard Operating Procedures. Any technical or administrative problems during analysis, data review, and reduction are listed below by analytical parameter.
Analytical Request:
Sixteen soil samples were analyzed for FSSGAM.
Two soil samples were analyzed for FSSALL.
Internal Chain of Custody:
Custody was maintained for the sample(s).
Data Package:
The enclosed data package contains the following sections: Case Narrative, Chain of Custody and Supporting Documentation and all analytical fractions.
I certify that this data package is in compliance with the SOW, both technically and for completeness, for other than the conditions detailed above. Release of the data contained in this hard copy data package has been authorized by the Laboratory Manager or a designee, as verified by the following signature.
Cheryl Jones Project Manager GENERAL ENGINEERING LABORATORIES, LLC a Member of THE GEL GROUP INC.
- P.O. Box 30712 # Charleston, SC 29417
- 2040 Savage Road (29407)
Phone (843) 556-8171
- Fax (843) 766-1178. www.gel.com (37
List of current GEL Certifications as of 26 September 2006 State Alaska Arizona Arkansas CLIA California Colorado Connecticut Dept. of Navy EPA Florida/NELAP Georgia Hawaii Idaho Illinois Indiana Kansas Kentucky Louisiana Maryland Massachusetts Michigan Nevada New Jersey New Mexico New York North Carolina North Carolina Drinking W North Dakota Oklahoma Pennsylvania South Carolýna Tennessee Texas Certification UST-062 AZ0668 88-0651 42D09O4046_
01151CA GenEngLabs PH-0169 NFESC 413 WG-15J E87 156 E8.7156,(Fl-NELA.P)
N/A N/A 200029 C-SC-0I E-10332 90129 03046 270 M-SC012 9903 SCi2 SCO02 FL NELAP E87 156 11501 233 45709 R-158 9904 68-00485 10120001/j)585001/1 01200002 02934 TX213-2006A T 104704235-06-TX S-52597 N/A 8037697376 GEL
\\t -gi 3-6.....
Texas NELAP U.S. Dept. of Agriculture US Army Corps of Engineer Utah Vermont Virginia Wahington 00151 C1641 4
Chain of Custody And Supporting Documentation 5
Health Physics Procedure GPP-GGGR-R5104-003 -Attachment B-CY-001 Major Connecticut Yankee Atomic Power Company Chain of Custody Form No. 2006-00566 362 Injun Hollow Road, East Hampton, CT 06424 860-267-2556 Project Name: Haddam Neck Decommissioning Analyses Requested Lab Use Only Contact Name & Phone:
Comments:
Jack McCarthy 860-267-3924 Analytical Lab (Name, City, State)
General Engineering Laboratories 2040 Savage Road. Charleston SC. 29407 C
843 556 8171. Attn. Cheryl Jones Priority: [] 30 D. Z 14 D. 1 7 D. 13 D.
C Container Sample Size-Sample Designation Date Time Media Type
&Type Comment. Preservation Lab Sample ID Code Code Code 9530-0003-OO1F 9/12/06 1042 TS G
BP X
9530-0003-002F 9/12/06 1047 TS G
BP X
9530-0003-003F 9/12/06 1051 TS G
BP X
9530-0003-004F 9/12/06 1101 TS G
BP X
9530-0003-004FS 9/12/06 1101 TS G
BP X
9530-0003-005F 9/12/06 1105 TS G
BP X
9530-0003-006F 9/12/06 1105 TS G
BP X
9530-0003-006FS 9/12/06 1105 TS G
BP X
9530-0003-007F 9/12/06 1325 TS G
BP X
NOTES: PO #: 002332 MSR #: 06-12S.%'
[] Radwaste QA 11 Non QA Samples Shipped Via:
Z Fed Ex RI UPS 1] Hand El Other Rill nfT.Vdlina; Internal Container Temp.: 27 Deg.
C Custody Sealed?
Y,,< N l Custody Seal Intact?
Y, N E;
- 1) Relinquished B Date/Time
- 2)
Date/Time
- 3) Relinquis Date/Time
- 4) Received By Date/Time
Health Physics Procedure GPP-GGGR-R5104-003-Attachment B-CY-001 Major Connecticut Yankee Atomic Power Company Chain of Custody Form No. 2006-00567 362 Injun Hollow Road, East Hampton, CT 06424 860-267-2556 Project Name: Haddam Neck Decommissioning Analyses Requested Lab Use Only Contact Name & Phone:
Comments:
Jack McCarthy 860-267-3924 Analytical Lab (Name, City, State)
General Engineering Laboratories 2040 Savage Road. Charleston SC. 29407 843 556 8171. Attn. Cheryl Jones Priority: [] 30 D. Z 14 D. [: 7 D. [
3 D.
C Container Sample Size-Sample Designation Date Time Media Type
&Type Comment, Preservation Lab Sample ID Code Code Code 9530-0003-008F 9/12/06 1343 TS G
BP X
9530-0003-009F 9/12/06 1356 TS G
BP X
9530-0003-OIOF 9/12/06 1121 TS G
BP X
9530-0003-01 IF 9/12/06 1427 TS G
BP X
9530-0003-012F 9/12/06 1440 TS G
BP X
9530-0003-013F 9/12/06 1446 TS G
BP X
9530-0003-014F 9/12/06 1457 TS G
BP X
9530-0003-015F 9/12/06 1453 TS G
BP X
9530-0003-016F 9/12/06 1505 TS G
BP X
NOTES: PO #: 002332 MSR #: 06-/Zd'f SSWP# NA Z LTP QA 0
Radwaste QA IZ Non QA Samples Shipped Via:
Z Fed Ex FD UPS ED Hand E] Other Bill of Lading //
Internal Container Temp.: Q_*Oeg.
C Custody'sealed?
Y, NV-Custody Seal Intact?
Y-Z N,'
- 1) Relinquished By Date/ ime
- 2) ived By Date/Time
- 3) Relinquishd By aDate/Time
- 4) Received By Date/Time
Connecticut Yankee Statement of Work for Analytical Lab Services CY-ISC-SOW-001 Figure 1. Sample Check-in List Date/Time Received:_____________________________
SDG#:
MI Work Order Number:
Shipping Container ID:. 1) t3 343 Chain of Custody# *,D.
()
S
- 1.
Custody Seals or shipping container intact?..
Yes ( )No
(]
- 2.
Custody Seals dated and signed?
Yes o [
No
- 3.
Chain-of-Custody record present?
Yes [
Not]
- 4.
Cooler temperature
- 5.
Vermiculite/packing materials is:
Wet [ ]Dry 6.*
Number of samples in shipping container:
- 7.
Sample holding times exceeded?
Yes [ ] No
.8. Samples have:
-)(-tape hazard labels custody seals appropriate sample labels
- 9. Samples are'
.4 in good condition leaking
____b roken
.have air bubbles
- 10.
Were any anomalies identified in sample receipt?
Yes []No 7
]I.
.Description of anomalies (include sample numbers):
Sample Custodian/Laboratory:_
Date_
Telephoned to:
On By
RADIOLOGICAL ANALYSIS 9
Radiochemistry Case Narrative Connecticut Yankee Atomic Power Co. (YANK)
Work Order 171772 Method/Analysis Information Product:
Alphaspec Am241, Cm, Solid ALL FSS DOE EML HASL-300, Am-05-RC Modified Analytical Method:
Prep Method:
Dry Soil Prep GL-RAD-A-021 Method:
Analytical Batch Number:
Prep Batch Number:
Dry Soil Prep GL-RAD-A-021 Batch Number:
Ash Soil Prep Dry Soil Prep 569530 569079 569078 Sample ID 171772015 171772016 1201185572 1201185573 1201185574 1201185575 Client ID 9530-0003-013F 9530-0003-014F Method Blank (MB) 171772015(9530-0003-013F) Sample Duplicate (DUP) 171772015(9530-0003-013F) Matrix Spike (MS)
Laboratory Control Sample (LCS)
SOP Reference Procedure for preparation, analysis and reporting of analytical data are controlled by General Engineering Laboratories, LLC as Standard Operating Procedure (SOP). The data discussed in this narrative has been analyzed in accordance with GL-RAD-A-01 1 REV# 14.
Calibration Information:
Calibration Information All initial and continuing calibration requirements have been met.
Standards Information Standard solution(s) for these analyses are NIST traceable and used before the expiration date(s).
Sample Geometry All counting sources were prepared in the same geometry as the calibration standards.
10
Quality Control (QC) Information:
Blank Information The blank volume is representative of the sample volume in this batch.
Designated QC The following sample was used for QC: 171772015 (9530-0003-013F).
QC Information All of the QC samples met the required acceptance limits.
Technical Information:
Holding Time All sample procedures for this sample set were performed within the required holding time.
Preparation Information All preparation criteria have been met for these analyses.
Sample Re-prep/Re-analysis Sample 1201185572 (MB) was recounted due to a negative result greater than three times the error.
Miscellaneous Information:
NCR Documentation Nonconformance reports are generated to document any procedural anomalies that may deviate from referenced SOP or contractual documents. A nonconformance report (NCR) was not generated for this SDG.
Manual Integration No manual integrations were performed on data in this batch.
Additional Comments Additional comments were not required for this sample set.
Qualifier information Manual qualifiers were not required.
Method/Analysis Information 11
Product:
Alphaspec Pu, Solid-ALL FSS Analytical Method:
DOE EML HASL-300, Pu-11-RC Modified Prep Method:
Dry Soil Prep GL-RAD-A-021 Method:
Analytical Batch Number:
Prep Batch Number:
Dry Soil Prep GL-RAD-A-021 Batch Number:
Ash Soil Prep Dry Soil Prep 569531 569079 569078 Sample ID 171772015 171772016 1201185576 1201185577 1201185578 1201185579 Client ID 9530-0003-013F 9530-0003-014F Method Blank (MB) 171772015(9530-0003-013F) Sample Duplicate (DUP) 171772015(9530-0003-013F) Matrix Spike (MS)
Laboratory Control Sample (LCS)
SOP Reference Procedure for preparation, analysis and reporting of analytical data are controlled by General Engineering Laboratories, LLC as Standard Operating Procedure (SOP). The data discussed in this narrative has been analyzed in accordance with GL-RAD-A-0 11 REV# 14.
Calibration Information:
Calibration Information All initial and continuing calibration requirements have been met.
Standards Information Standard solution(s) for these analyses are NIST traceable and used before the expiration date(s).
Sample Geometry All counting sources were prepared in the same geometry as the calibration standards.
Quality Control (QC) Information:
Blank Information The blank volume is representative of the sample volume in this batch.
Designated QC The following sample was used for QC: 171772015 (9530-0003-013F).
QC Information All of the QC samples met the required acceptance limits.
12
Technical Information:
Holding Time All sample procedures for this sample set were performed within the required holding time.
Preparation Information All preparation criteria have been met for these analyses.
Sample Re-prep/Re-analysis None of the samples in this sample set required reprep or reanalysis.
Miscellaneous Information:
NCR Documentation Nonconformance reports are generated to document any procedural anomalies that may deviate from referenced SOP or contractual documents. A nonconformance report (NCR) was not generated for this SDG.
Manual Integration No manual integrations were performed on data in this batch.
Additional Comments Additional comments were not required for this sample set.
Qualifier information Manual qualifiers were not required.
Method/Analysis Information Product:
Liquid Scint Pu241, Solid-ALL FSS DOE EML HASL-300, Pu-I I-RC Modified Analytical Method:
Prep Method:
Dry Soil Prep GL-RAD-A-021 Method:
Analytical Batch Number:
Prep Batch Number:
Dry Soil Prep GL-RAD-A-021 Batch Number:
Ash Soil Prep Dry Soil Prep 573310 569079 569078 13
Sample ID Client ID 171772015 9530-0003-013F 171772016 9530-0003-014F 1201194062 Method Blank (MB) 1201194063 171772015(9530-0003-013F) Sample Duplicate (DUP) 1201194064 171772015(9530-0003-013F) Matrix Spike (MS) 1201194065 Laboratory Control Sample (LCS)
SOP Reference Procedure for preparation, analysis and reporting of analytical data are controlled by General Engineering Laboratories, LLC as Standard Operating Procedure (SOP). The data discussed in this narrative has been analyzed in accordance with GL-RAD-A-035 REV# 8.
Calibration Information:
Calibration Information All initial and continuing calibration requirements have been met.
Standards Information Standard solution(s) for these analyses are NIST traceable and used before the expiration date(s).
Sample Geometry All counting sources were prepared in the same geometry as the calibration standards.
Quality Control (QC) Information:
Blank Information The blank volume is representative of the sample volume in this batch.
Designated QC The following sample was used for QC: 171772015 (9530-0003-013F).
QC Information All of the QC samples met the required acceptance limits.
Technical Information:
Holding Time All sample procedures for this sample set were performed within the required holding time.
Preparation Information All preparation criteria have been met for these analyses.
Sample Re-prep/Re-analysis Samples were reprepped due to low/high carrier/tracer yield.
Miscellaneous Information:
NCR Documentation Nonconformance reports are generated to document any procedural anomalies that may deviate from 14
referenced SOP or contractual documents. A nonconformance report (NCR) was not generated for this SDG.
Manual Integration No manual integrations were performed on data in this batch.
Additional Comments Additional comments were not required for this sample set.
Qualifier information Manual qualifiers were not required.
Method/Analysis Information Product:
Analytical Method:
Prep Method:
Analytical Batch Number:
Prep Batch Number:
Sample ID 171772001 171772002 171772003 171772004 171772005 171772006 171772007 171772008 171772009 171772010 171772011 171772012 171772013 171772014 171772015 171772016 171772017 171772018 1201185431 1201185432 1201185433 Gamma,Solid-FSS GAM & ALL FSS 226 Ingrowth Waived EML HASL 300, 4.5.2.3 Dry Soil Prep 569469 569078 Client ID 9530-0003-001F 9530-0003-002F 9530-0003-003F 9530-0003-004F 9530-0003-004FS 9530-0003-005F 9530-0003-006F 9530-0003-006FS 9530-0003-007F 9530-0003-008F 9530-0003-009F 9530-0003-01OF 9530-0003-01 IF 9530-0003-012F 9530-0003-013F 9530-0003-014F 9530-0003-015F 9530-0003-016F Method Blank (MB) 171772001(9530-0003-001 F) Sample Duplicate (DUP)
Laboratory Control Sample (LCS) 15
SOP Reference Procedure for preparation, analysis and reporting of analytical data are controlled by General Engineering Laboratories, LLC as Standard Operating Procedure (SOP). The data discussed in this narrative has been analyzed in accordance with GL-RAD-A-013 REV# 12.
Calibration Information:
Calibration Information All initial and continuing calibration requirements have been met.
Standards Information Standard solution(s) for these analyses are NIST traceable and used before the expiration date(s).
Sample Geometry All counting sources were prepared in the same geometry as the calibration standards.
Quality Control (QC) Information:
Blank Information The blank volume is representative of the sample volume in this batch.
Designated QC The following sample was used for QC: 171772001 (9530-0003-001F).
QC Information All of the QC samples met the required acceptance limits.
Technical Information:
Holding Time All sample procedures for this sample set were performed within the required holding time.
Preparation Information All preparation criteria have been met for these analyses.
Sample Re-prep/Re-analysis Samples 171772001 (9530-0003-001F), 171772004 (9530-0003-004F), 171772005 (9530-0003-004FS), 171772006 (9530-0003-005F), 171772016 (9530-0003-014F), 171772017 (9530-0003-015F) and 171772018 (9530-0003-016F) were recounted due to high MDAs.
Miscellaneous Information:
NCR Documentation Nonconformance reports are generated to document any procedural anomalies that may deviate from referenced SOP or contractual documents. A nonconformance report (NCR) was not generated for this SDG.
Additional Comments Additional comments were not required for this sample set.
16
Oualifier information Qualifier UI Reason Data rejected due to interference.
Analyte Europium-155 UI Manganese-54 Data rejected due to low abundance.
Actinium-228 Bismuth-214 Cesium-134 Sample 171772004 171772011 171772013 171772014 171772015 171772011 171772012 171772012 1201185431 171772005 171772006 171772008 171772009 171772010 171772011 171772013 171772014 171772015 171772017 1201185432 1201185431 UI Data rejected due to no valid peak.
Radium-226 Method/Analysis Information 17
Product:
GFPC, Sr90, solid-ALL FSS Analytical Method:
EPA 905.0 Modified Prep Method:
Dry Soil Prep GL-RAD-A-021 Method:
Analytical Batch Number:
Prep Batch Number:
Dry Soil Prep GL-RAD-A-021 Batch Number:
Ash Soil Prep Dry Soil Prep 569258 569079 569078 Sample ID 171772015 171772016 1201184955 1201184956 1201184957 1201184958 Client ID 9530-0003-013F 9530-0003-014F Method Blank (MB) 171772015(9530-0003-013F) Sample Duplicate (DUP) 171772015(9530-0003-013F) Matrix Spike (MS)
Laboratory Control Sample (LCS)
SOP Reference Procedure for preparation, analysis and reporting of analytical data are controlled by General Engineering Laboratories, LLC as Standard Operating Procedure (SOP). The data discussed in this narrative has been analyzed in accordance with GL-RAD-A-004 REV# 10.
Calibration Information:
Calibration Information All initial and continuing calibration requirements have been met.
Standards Information Standard solution(s) for these analyses are NIST traceable and used before the expiration date(s).
Sample Geometry All counting sources were prepared in the same geometry as the calibration standards.
Quality Control (OC) Information:
Blank Information The blank volume is representative of the sample volumes in this batch.
Designated QC The following sample was used for QC: 171772015 (9530-0003-013F).
QC Information All of the QC samples met the required acceptance limits.
18
Technical Information:
Holding Time All sample procedures for this sample set were performed within the required holding time.
Preparation Information All preparation criteria have been met for these analyses.
Sample Re-prep/Re-analysis The batch was recounted due to a high relative percent difference.
Chemical Recoveries All chemical recoveries meet the required acceptance limits for this sample set.
Miscellaneous Information:
NCR Documentation Nonconformance reports are generated to document any procedural anomalies that may deviate from referenced SOP or contractual documents. A nonconformance report (NCR) was not generated for this SDG.
Additional Comments Additional comments were not required for this sample set.
Qualifier information Manual qualifiers were not required.
Method/Analysis Information Product:
Liquid Scint Tc99, Solid-ALL FSS Analytical Method:
Analytical Batch Number:
Sample ID 171772015 171772016 1201184719 1201184720 1201184721 1201184722 DOE EML HASL-300, Tc-02-RC Modified 569161 Client ID 9530-0003-013F 9530-0003-014F Method Blank (MB) 171772015(9530-0003-013F) Sample Duplicate (DUP) 171772015(9530-0003-013F) Matrix Spike (MS)
Laboratory Control Sample (LCS)
SOP Reference Procedure for preparation, analysis and reporting of analytical data are controlled by General Engineering Laboratories, LLC as Standard Operating Procedure (SOP). The data discussed in this 19
narrative has been analyzed in accordance with GL-RAD-A-005 REV# 13.
Calibration Information:
Calibration Information All initial and continuing calibration requirements have been met.
Standards Information Standard solution(s) for these analyses are NIST traceable and used before the expiration date(s).
Sample Geometry All counting sources were prepared in the same geometry as the calibration standards.
Quality Control (QC) Information:
Blank Information The blank volume is representative of the sample volume in this batch.
Designated QC The following sample was used for QC: 171772015 (9530-0003-013F).
QC Information All of the QC samples met the required acceptance limits.
Technical Information:
Holding Time All sample procedures for this sample set were performed within the required holding time.
Preparation Information All preparation criteria have been met for these analyses.
Sample Re-prep/Re-analysis Sample 171772016 (9530-0003-014F) was recounted due to high MDA.
Miscellaneous Information:
NCR Documentation Nonconformance reports are generated to document any procedural anomalies that may deviate from referenced SOP or contractual documents. A nonconformance report (NCR) was not generated for this SDG.
Additional Comments Additional comments were not required for this sample set.
Qualifier information Manual qualifiers were not required.
Method/Analysis Information 20
Product:
Liquid Scint Fe55, Solid-ALL FSS Analytical Method:
DOE RESL Fe-1, Modified Prep Method:
Dry Soil Prep GL-RAD-A-021 Method:
Analytical Batch Number:
Prep Batch Number:
Dry Soil Prep GL-RAD-A-021 Batch Number:
Ash Soil Prep Dry Soil Prep 569145 569079 569078 Sample ID 171772015 171772016 1201184670 1201184671 1201184672 1201184673 Client ID 9530-0003-013F 9530-0003-014F Method Blank (MB) 171772016(9530-0003-014F) Sample Duplicate (DUP) 171772016(9530-0003-014F) Matrix Spike (MS)
Laboratory Control Sample (LCS)
SOP Reference Procedure for preparation, analysis and reporting of analytical data are controlled by General Engineering Laboratories, LLC as Standard Operating Procedure (SOP). The data discussed in this narrative has been analyzed in accordance with GL-RAD-A-040 REV# 3.
Calibration Information:
Calibration Information All initial and continuing calibration requirements have been met.
Standards Information Standard solution(s) for these analyses are NIST traceable and used before the expiration date(s).
Sample Geometry All counting sources were prepared in the same geometry as the calibration standards.
Quality Control (QC) Information:
Blank Information The blank volume is representative of the sample volume in this batch.
Designated QC The following sample was used for QC: 171772016 (9530-0003-014F).
QC Information All of the QC samples met the required acceptance limits.
21
Technical Information:
Holding Time All sample procedures for this sample set were performed within the required holding time.
Preparation Information All preparation criteria have been met for these analyses.
Sample Re-prep/Re-analysis None of the samples in this sample set required reprep or reanalysis.
Miscellaneous Information:
NCR Documentation Nonconformance reports are generated to document any procedural anomalies that may deviate from referenced SOP or contractual documents. A nonconformance report (NCR) was not generated for this SDG.
Additional Comments Additional comments were not required for this sample set.
Qualifier information Manual qualifiers were not required.
Method/Analysis Information Product:
Liquid Scint Ni63, Solid-ALL FSS Analytical Method:
DOE RESL Ni-1, Modified Prep Method:
Dry Soil Prep GL-RAD-A-021 Method:
Analytical Batch Number:
Prep Batch Number:
Dry Soil Prep GL-RAD-A-021 Batch Number:
Ash Soil Prep Dry Soil Prep 569146 569079 569078 Sample ID 171772015 171772016 1201184674 1201184675 1201184676 1201184677 Client ID 9530-0003-013F 9530-0003-014F Method Blank (MB) 171772016(9530-0003-014F) Sample Duplicate (DUP) 171772016(9530-0003-014F) Matrix Spike (MS)
Laboratory Control Sample (LCS) 22
SOP Reference Procedure for preparation, analysis and reporting of analytical data are controlled by General Engineering Laboratories, LLC as Standard Operating Procedure (SOP). The data discussed in this narrative has been analyzed in accordance with GL-RAD-A-022 REV# 8.
Calibration Information:
Calibration Information All initial and continuing calibration requirements have been met.
Standards Information Standard solution(s) for these analyses are NIST traceable and used before the expiration date(s).
Sample Geometry All counting sources were prepared in the same geometry as the calibration standards.
Quality Control (Q0 Information:
Blank Information The blank volume is representative of the sample volume in this batch.
Designated QC The following sample was used for QC: 171772016 (9530-0003-014F).
QC Information All of the QC samples met the required acceptance limits.
Technical Information:
Holding Time All sample procedures for this sample set were performed within the required holding time.
Preparation Information All preparation criteria have been met for these analyses.
Sample Re-prep/Re-analysis None of the samples in this sample set required reprep or reanalysis.
Miscellaneous Information:
NCR Documentation Nonconformance reports are generated to document any procedural anomalies that may deviate from referenced SOP or contractual documents. A nonconformance report (NCR) was not generated for this SDG.
Additional Comments Additional comments were not required for this sample set.
23
Qualifier information Manual qualifiers were not required.
Method/Analysis Information Product:
LSC, Tritium Dist, Solid-HTD2,ALL FSS Analytical Method:
Analytical Batch Number:
Sample ID 171772015 171772016 1201184634 1201184635 1201184636 1201184637 EPA 906.0 Modified 569133 Client ID 9530-0003-013F 9530-0003-014F Method Blank (MB) 171772015(9530-0003-013F) Sample Duplicate (DUP) 171772015(9530-0003-013F) Matrix Spike (MS)
Laboratory Control Sample (LCS)
SOP Reference Procedure for preparation, analysis and reporting of analytical data are controlled by General Engineering Laboratories, LLC as Standard Operating Procedure (SOP). The data discussed in this narrative has been analyzed in accordance with GL-RAD-A-002 REV# 13.
Calibration Information:
Calibration Information All initial and continuing calibration requirements have been met.
Standards Information Standard solution(s) for these analyses are NIST traceable and used before the expiration date(s).
Sample Geometry All counting sources were prepared in the same geometry as the calibration standards.
Quality Control (0C) Information:
Blank Information The blank volume is representative of the sample volumes in this batch.
Designated QC The following sample was used for QC: 171772015 (9530-0003-013F).
QC Information All of the QC samples met the required acceptance limits.
24
Technical Information:
Holding Time All sample procedures for this sample set were performed within the required holding time.
Preparation Information All preparation criteria have been met for these analyses.
Sample Re-prep/Re-analysis Samples 1201184634 (MB), 1201184635 (9530-0003-013F), 171772015 (9530-0003-013F) and 171772016 (9530-0003-014F) were recounted due to high MDAs.
Miscellaneous Information:
NCR Documentation Nonconformance reports are generated to document any procedural anomalies that may deviate from referenced SOP or contractual documents. A nonconformance report (NCR) was not generated for this SDG.
Additional Comments Additional comments were not required for this sample set.
Qualifier information Manual qualifiers were not required.
Method/Analysis Information Product:
Liquid Scint C14, Solid AlI,FSS Analytical Method:
Analytical Batch Number:
Sample ID 171772015 171772016 1201192245 1201192246 1201192247 1201192248 EPA EERF C-0l Modified 572496 Client ID 9530-0003-013F 9530-0003-014F Method Blank (MB) 171772015(9530-0003-013F) Sample Duplicate (DUP) 171772015(9530-0003-013F) Matrix Spike (MS)
Laboratory Control Sample (LCS)
SOP Reference Procedure for preparation, analysis and reporting of analytical data are controlled by General Engineering Laboratories, LLC as Standard Operating Procedure (SOP). The data discussed in this narrative has been analyzed in accordance with GL-RAD-A-003 REV# 8.
25
Calibration Information:
Calibration Information All initial and continuing calibration requirements have been met.
Standards Information Standard solution(s) for these analyses are NIST traceable and used before the expiration date(s).
Sample Geometry All counting sources were prepared in the same geometry as the calibration standards.
Quality Control (Q0 Information:
Blank Information The blank volume is representative of the sample volume in this batch.
Designated QC The following sample was used for QC: 171772015 (9530-0003-013F).
QC Information All of the QC samples met the required acceptance limits.
Technical Information:
Holding Time All sample procedures for this sample set were performed within the required holding time.
Preparation Information All preparation criteria have been met for these analyses.
Sample Re-prep/Re-analysis Samples 171772015 (9530-0003-013F) and 171772016 (9530-0003-014F) were reprepped due to low/high recovery.
Miscellaneous Information:
NCR Documentation Nonconformance reports are generated to document any procedural anomalies that may deviate from referenced SOP or contractual documents. A nonconformance report (NCR) was not generated for this SDG.
Additional Comments Additional comments were not required for this sample set.
Qualifier information Manual qualifiers were not required.
Certification Statement 26
Where the analytical method has been performed under NELAP certification, the analysis has met all of the requirements of the NELAC standard unless otherwise noted in the analytical case narrative.
Review Validation:
GEL requires all analytical data to be verified by a qualified data validator. In addition, all data designated for CLP or CLP-like packaging will receive a third level validation upon completion of the data package.
The following data validator verified the information presented in this case narrative:
Reviewer/Date:
V
('Ql LP ol 27
SAMPLE DATA
SUMMARY
28
GENERAL ENGINEERING LABORATORIES, LLC 2040 Savage Road Charleston SC 29407 - (843) 556-8171 - www.gel.com Certificate of Analysis Report for YANK001 Connecticut Yankee Atomic Power Co.
Client SDG: MSR#06-1255 GEL Work Order: 171772 The Qualifiers in this report are defined as follows:
A quality control analyte recovery is outside of specified acceptance criteria Analyte is a surrogate compound U
Analyte was analyzed for, but not detected above the MDL, MDA, or LOD.
UI Gamma Spectroscopy--Uncertain identification ND The analyte concentration is not detected above the detection limit.
The above sample is reported on a dry weight basis except where prohibited by the analytical procedure.
Where the analytical method has been performed under NELAP certification, the analysis has met all of the requirements of the NELAC standard unless qualified on the Certificate of Analysis.
This data report has been prepared and reviewed in accordance with General Engineering Laboratories, LLC standard operating procedures. Please direct any questions to your Project Manager, Cheryl Jones.
Reviewed by 29
GENERAL ENGINEERING LABORATORIES, LLC 2040 Savage Road Charleston SC 29407 - (843) 556-8171 - www.gel.com Certificate of Analysis Company : Connecticut Yankee Atomic Power Address:
362 Injun Hollow Rd East Hampton, Connecticut 06424
Contact:
Mr. Jack McCarthy Project:
Soils PO# 002332 Report Date: October 3, 2006 Client Sample ID:
9530-0003-00IF Project:
YANK01204 Sample ID:
171772001 Client ID:
YANKOO Matrix:
TS Vol. Recv.:
Collect Date:
12-SEP-06 Receive Date:
15-SEP-06 Collector:
Client Moisture:
23.2%
Parameter Qualifier Result Uncertainty LC TPU MDA Units DF Analyst Date Time Batch Mtd Rad Gamma Spec Analysis Gamma,Solid-FSS GAM & ALL FSS 226 Ingrowth Waived Actinium-228 1.00 Americium-241 U
0.0354 Bismuth-212 0.465 Bismuth-214 0.531 Cesium-134 U
0.0412 Cesium-137 0.141 Cobalt-60 U -3.370E-Europium-152 Europium-154 Europium-155 Lead-212 Lead-214 Manganese-54 Niobium-94 Potassium-40 Radium-226 Silver-108m Thallium-208 05 U
0.0209 U
-0.0547 U
0.111 0.766 0.545 U -0.00902 U -0.00508 15.0 0.531 U
-0.013 0.272 H
-I H
-I
+/-0.199
+/-0.071
+/-0.287
+/-0.104
+/-0.0379
+/-0.0362
+/-0.0257 4-0.0776 4-0.0796 4-0.0802 4-0.0868 4-0.0993 4-0.0261 4-0.0217
+/-1.36
+/-0.104 4/-0.0226
,/-0.0562 0.0629 0.0622 0.171 0.039 0.0245 0.0203 0.0216 0.0593 0.0622 0.0548 0.0316 0.0441 0.0209 0.0178 0.174 0.039 0.0186 0.0204
+/-0.199
+/-0.071
+/-0.287
+/-0.104
+/-0.0379
+/-0.0362
+/-0.0257
+/-0.0776
+/-0.0796
+/-0.0802
+/-0.0868
+/-0.0993
+/-0.0261
+/-0.0217
+/-1.36
+/-0.104
+/-0.0226
+/-0.0562 0.137 0.128 0.364 0.0826 0.0522 0.0433 0.0475 0.124 0.136 0.113 0.0656 0.0919 0.0447 0.0379 0.391 0.0826 0.0391 0.0432 pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g MJHI 09/27/06 1300 569469 1
The following Prep Methods were performed Method Description Analyst Date Time Prep Batch Dry Soil Prep Dry Soil Prep GL-RAD-A-021 LXM1 09/15/06 1530 569078 The following Analytical Methods were performed Method Description 1
EML HASL 300, 4.5.2.3 Notes:
The Qualifiers in this report are defined as follows:
A quality control analyte recovery is outside of specified acceptance criteria 30
GENERAL ENGINEERING LABORATORIES, LLC 2040 Savage Road Charleston SC 29407 - (843) 556-8171 - www.gel.com Certificate of Analysis Company:
Connecticut Yankee Atomic Power Address:
362 Injun Hollow Rd East Hampton, Connecticut 06424 Report Date: October 3, 2006
Contact:
Mr. Jack McCarthy Project:
Soils PO# 002332 Client Sample ID:
9530-0003-OOIF Project:
YANK01204 Sample ID:
171772001 ClientID:
YANK001 Vol. Recv.:
Parameter Qualifier Result Uncertainty LC TPU MDA Units DF Analyst Date Time Batch Mtd Result is less than value reported Result is greater than value reported A
The TIC is a suspected aldol-condensation product B
Target analyte was detected in the associated blank BD Results are either below the MDC or tracer recovery is low C
Analyte has been confirmed by GC/MS analysis D
Results are reported from a diluted aliquot of the sample H
Analytical holding time was exceeded J
Value is estimated N/A Spike recovery limits do not apply. Sample concentration exceeds spike concentration by 4X or more R
Sample results are rejected U
Analyte was analyzed for, but not detected above the MDL, MDA, or LOD.
UI Gamma Spectroscopy--Uncertain identification X
Consult Case Narrative, Data Summary package, or Project Manager concerning this qualifier Y
QC Samples were not spiked with this compound A
RPD of sample and duplicate evaluated using +/-RL. Concentrations are <5X the RL h
Preparation or preservation holding time was exceeded The above sample is reported on a dry weight basis.
31
GENERAL ENGINEERING LABORATORIES, LLC 2040 Savage Road Charleston SC 29407 - (843) 556-8171 - www.gel.com Certificate of Analysis Company : Connecticut Yankee Atomic Power Address:
362 Injun Hollow Rd East Hampton, Connecticut 06424
Contact:
Mr. Jack McCarthy Project:
Soils PO# 002332 Report Date: October 3, 2006 Client Sample ID:
Sample ID:
Matrix:
Collect Date:
Receive Date:
Collector:
Moisture:
9530-0003-002F 171772002 TS 12-SEP-06 15-SEP-06 Client 18.4%
Project:
Client ID:
Vol. Recv.:
YANK01204 YANK001 Parameter Qualifier Result Uncertainty LC TPU MDA Units DF Analyst Date Time Batch Mtd Rad Gamma Spec Analysis Gamma,Solid-FSS GAM & ALL FSS 226 Ingrowth Waived Actinium-228 1.03 Americium-241 U
-0.0227 Bismuth-212 U
0.439 Bismuth-214 0.764 Cesium-134 U
0.0205 Cesium-137 0.326 Cobalt-60 U
0.00301 Europium-152 U
-0.0163 Europium-154 U
-0.0746 Europium-155 U
0.0756 Lead-212 0.766 Lead-214 0.550 Manganese-54 U 0.000407 Niobium-94 U -0.00308 Potassium-40 13.6 Radium-226 0.764 Silver-108m U
-0.0291 Thallium-208 0.354
+/-0.262 4/-0.0503
+/-0.549
+/-0.164 1/-0.0567
+/-0.0926 1/-0.0498
+/-0.0943
+/-0.137 1/-0.0874
-/-0.0981
+/-0.136 4/-0.0544 4/-0.0377
+/-1.64
+/-0.164 4/-0.0339
-/-0.0715 0.0873 0.0428 0.231 0.0574 0.0481 0.0323 0.0418 0.0803 0.105 0.0779 0.0465 0.0605 0.0387 0.0308 0.297 0.0574 0.0265 0.0337
+/-0.262
+/-0.0503
+/-0.549
+/-0.164
+/-0.0567
+/-0.0926
+/-0.0498
+/-0.0943
+/-0.137
+/-0.0874
+/-0.0981
+/-0.136
+/-0.0544
+/-0.0377
+/-1.64
+/-0.164
+/-0.0339
+/-0.0715 0.202 0.0894 0.514 0.126 0.104 0.0712 0.0942 0.172 0.238 0.163 0.098 0.129 0.0845 0.0675 0.701 0.126 0.0577 0.0734 pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g MJH 1 09/22/06 0822 569469 1
The following Prep Methods were performed Method Description Analyst Date Time Prep Batch Dry Soil Prep Dry Soil Prep GL-RAD-A-021 LXMI 09/15/06 1530 569078 The following Analytical Methods were performed Method Description I
EEML HASL 300, 4.5.2.3 Notes:
The Qualifiers in this report are defined as follows:
A quality control analyte recovery is outside of specified acceptance criteria Result is less than value reported 32
GENERAL ENGINEERING LABORATORIES, LLC 2040 Savage Road Charleston SC 29407 - (843) 556-8171 - www.gel.com Certificate of Analysis Company Connecticut Yankee Atomic Power Address 362 Injun Hollow Rd East Hampton, Connecticut 06424 Report Date: October 3, 2006
Contact:
Mr. Jack McCarthy Project:
Soils PO# 002332 Client Sample ID:
9530-0003-002F Project:
YANK01204 Sample ID:
171772002 Client ID:
YANKOOl Vol. Recv.:
Parameter Qualifier Result Uncertainty LC TPU MDA Units DF Analyst Date Time Batch Mtd Result is greater than value reported A
The TIC is a suspected aldol-condensation product B
Target analyte was detected in the associated blank BD Results are either below the MDC or tracer recovery is low C
Analyte has been confirmed by GC/MS analysis D
Results.are reported from a diluted aliquot of the sample H
Analytical holding time was exceeded J
Value is estimated N/A Spike recovery limits do not apply. Sample concentration exceeds spike concentration by 4X or more R
Sampleresults are rejected U
Analyte was analyzed for, but not detected above the MDL, MDA, or LOD.
UI Gamma-Spectroscopy--Uncertain identification X
Consult Case Narrative, Data Summary package, or Project Manager concerning this qualifier Y
QC Samples were not spiked with this compound A
RPD of sample and duplicate evaluated using +/-RL. Concentrations are <5X the RL h
Preparation or preservation holding time was exceeded The above sample is reported on a dry weight basis.
33
GENERAL ENGINEERING LABORATORIES, LLC 2040 Savage Road Charleston SC 29407 - (843) 556-8171 - www.gel.com Certificate of Analysis Company:
Connecticut Yankee Atomic Power Address:
362 Injun Hollow Rd East Hampton, Connecticut 06424
Contact:
Mr. Jack McCarthy Project:
Soils PO# 002332 Report Date: October 3, 2006 Client Sample ID:
Sample ID:
Matrix:
Collect Date:
Receive Date:
Collector:
Moisture:
9530-0003-003F 171772003 TS 12-SEP-06 15-SEP-06 Client 34.2%
Project:
Client ID:
Vol. Recv.:
YANKO01204 YANK001 Parameter Qualifier Result Uncertainty LC TPU MDA Units DF Analyst Date Time Batch Mtd Rad Gamma Spec Analysis Gamma,Solid-FSS GAM & ALL FSS 226 Ingrowth Waived Actinium-228 1.31
+/-0.294 Americium-241 U
0.021
+/-0.0507 Bismuth-212 U
0.503
+/-0.584 Bismuth-214 0.897
+/-0.148 Cesium-134 U
0.0512
+/-0.0531 Cesium-137 0.283
+/-0.0918 Cobalt-60 U
0.00468
+/-0.0366 Europium-152 U
0.0296
+/-0.0847 Europium-154 U
-0.0443
+/-0.115 Europium-155 U
0.0278
+/-0.0842 Lead-212 1.19
+/-0.113 Lead-214 0.952
+/-0.171 Manganese-54 U -0.00228
+/-0.0362 Niobium-94 U
0.00389
+/-0.0366 Potassium-40 15.9
+/-1.64 Radium-226 0.897
+/-0.148 Silver-108m U
0.0254
+/-0.0316 Thallium-208 0.368
+/-0.0746 0.113 0.0443 0.252 0.0557 0.0402 0.0304 0.0308 0.0742 0.0888 0.072 0.044 0.0549 0.0306 0.0302 0.363 0.0557 0.0285 0.032
+/-0.294
+/-0.0507
+/-0.584
+/-0.148
+/-0.0531
+/-0.0918
+/-0.0366
+/-0.0847
+/-0.115
+/-0.0842
+/-0.113
+/-0.171
+/-0.0362
+/-0.0366
+/-1.64
+/-0.148
+/-0.0316
+/-0.0746 0.251 0.0918 0.549 0.121 0.0873 0.0667 0.0708 0.159 0.203 0.150 0.0926 0.117 0.0674 0.0656 0.819 0.121 0.061 0.0693 pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g MJH1 09/22/06 1007 569469 1
The following Prep Methods were performed Method Description Analyst Date Time Prep Batch Dry Soil Prep Dry Soil Prep GL-RAD-A-021 LXM1 09/15/06 1530 569078 The following Analytical Methods were performed Method Description 1
EML HASL 300, 4.5.2.3 Notes:
The Qualifiers in this report are defined as follows:
A quality control analyte recovery is outside of specified acceptance criteria Result is less than value reported 34
GENERAL ENGINEERING LABORATORIES, LLC 2040 Savage Road Charleston SC 29407 - (843) 556-8171 - www.gel.com Certificate of Analysis Company:
Connecticut Yankee Atomic Power Address:
362 Injun Hollow Rd East Hampton, Connecticut 06424 Report Date: October 3, 2006
Contact:
Mr. Jack McCarthy Project:
Soils PO# 002332 Client Sample ID:
9530-0003-003F Proiect:
YANK01204 Sample ID:
171772003 Client ID:
YANK001 Vol. Recv.:
Parameter Qualifier Result Uncertainty LC TPU MDA Units DF Analyst Date Time Batch Mtd Result is greater than value reported A
The TIC is a suspected aldol-condensation product B
Target analyte was detected in the associated blank BD Results are either below the MDC or tracer recovery is low C
Analyte has been confirmed by GC/MS analysis D
Results are reported from a diluted aliquot of the sample H
Analytical holding time was exceeded J
Value is estimated N/A Spike recovery limits do not apply. Sample concentration exceeds spike concentration by 4X or more R
Sample results are rejected U
Analyte was analyzed for, but not detected above the MDL, MDA, or LOD.
UI Gamma Spectroscopy--Uncertain identification X
Consult Case Narrative, Data Summary package, or Project Manager concerning this qualifier Y
QC Samples were not spiked with this compound A
RPD of sample and duplicate evaluated using +/-RL. Concentrations are <5X the RL h
Preparation or preservation holding time was exceeded The above sample is reported on a dry weight basis.
35
GENERAL ENGINEERING LABORATORIES, LLC 2040 Savage Road Charleston SC 29407 - (843) 556-8171 - www.gel.com Certificate of Analysis Company : Connecticut Yankee Atomic Power Address :
362 Injun Hollow Rd East Hampton, Connecticut 06424
Contact:
Mr. Jack McCarthy Project:
Soils PO# 002332 Report Date: October 3, 2006 Client Sample ID:
Sample ID:
Matrix:
Collect Date:
Receive Date:
Collector:
Moisture:
Parameter Qualifier Result U]
Rad Gamma Spec Analysis Gamma,Solid-FSS GAM & ALL FSS 226 Ingrowth Waived Actinium-228 1.56 Americium-241 U
-0.0256 Bismuth-212 U
0.268 Bismuth-214 0.861 Cesium-134 U
0.0649 Cesium-137 0.309 Cobalt-60 U
0.0236 Europium-152 U
0.0479 Europium-154 U
-0.0644 Europium-155 UI 0.00 Lead-212 1.52 Lead-214 1.23 Manganese-54 U
0.0389 Niobium-94 U
0.0259 Potassium-40 24.4 Radium-226 0.861 Silver-108m U
-0.0186 Thallium-208 0.427 9530-0003-004F 171772004 TS 12-SEP-06 15-SEP-06 Client 37.3%
Project:
Client ID:
Vol. Recv.:
YANKO 1204 YANK001 ncertainty LC TPU MDA Units DF Analyst Date Time Batch Mtd
+/-0.297
+/-0.0908
+/-0.418
+/-0.159
+/-0.0451
+/-0.0611
+/-0.0351
+/-0.0748
+/-0.0904
+/-0.119
+/-0.149
+/-0.171
+/-0.0359
+/-0.0273
+/-2.08
+/-0.159
+/-0.0269
+/-0.0809 0.0845 0.069 0.198 0.0437 0.0333 0.0277 0.0311 0.062 0.0698 0.0567 0.0314 0.0399 0.0222 0.0239 0.200 0.0437 0.0201 0.0237
+/-0.297
+/-0.0908
+/-0.418
+/-0.159
+/-0.0451
+/-0.0611
+/-0.0351
+/-0.0748
+/-0.0904
+/-0.119
+/-0.149
+/-0.171
+/-0.0359
+/-0.0273
+/-2.08
+/-0.159
+/-0.0269
+/-0.0809 0.182 0.143 0.421 0.0927 0.0703 0.0584 0.0672 0.130 0.153 0.118 0.0655 0.084 0.0478 0.0507 0.450 0.0927 0.0425 0.0503 pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g MJH1 09/27/06 1301 569469 1
The following Prep Methods were performed Method Description Analyst Date Time Prep Batch Dry Soil Prep Dry Soil Prep GL-RAD-A-021 LXM1 09/15/06 1530 569078 The following Analytical Methods were performed Method Description I
EML HASL 300, 4.5.2.3 Notes:
The Qualifiers in this report are defined as follows:
A quality control analyte recovery is outside of specified acceptance criteria Result is less than value reported 36
GENERAL ENGINEERING LABORATORIES, LLC 2040 Savage Road Charleston SC 29407 - (843) 556-8171 - www.gel.com Certificate of Analysis Company:
Connecticut Yankee Atomic Power Address :
362 Injun Hollow Rd East Hampton, Connecticut 06424 Report Date: October 3, 2006
Contact:
Mr. Jack McCarthy Project:
Soils PO# 002332 Client Sample ID:
9530-0003-004F Project:
YANK01204 Sample ID:
171772004 Client ID:
YANKO0I Vol. Recv.:
Parameter Qualifier Result Uncertainty LC TPU MDA Units DF Analyst Date Time Batch Mtd Result is greater than value reported A
The TIC is a suspected aldol-condensation product B
Target analyte was detected in the associated blank BD Results are either below the MDC or tracer recovery is low C
Analyte has been confirmed by GC/MS analysis D
Results are reported from a diluted aliquot of the sample H
Analytical holding time was exceeded J
Value is estimated N/A Spike recovery limits do not apply. Sample concentration exceeds spike concentration by 4X or more R
Sample results are rejected U
Analyte.was analyzed for, but not detected above the MDL, MDA, or LOD.
UI Gamma Spectroscopy--Uncertain identification X
Consult Case Narrative, Data Summary package, or Project Manager concerning this qualifier Y
QC Samples were not spiked with this compound A
RPD of sample and duplicate evaluated using +/-RL. Concentrations are <5X the RL h
Preparation or preservation holding time was exceeded The above sample is reported on a dry weight basis.
37
GENERAL ENGINEERING LABORATORIES, LLC 2040 Savage Road Charleston SC 29407 - (843) 556-8171 - www.gel.com Certificate of Analysis Company:
Connecticut Yankee Atomic Power Address:
362 Injun Hollow Rd East Hampton, Connecticut 06424
Contact:
Mr. Jack McCarthy Project:
Soils PO# 002332 Report Date: October 3, 2006 Client Sample ID:
Sample ID:
Matrix:
Collect Date:
Receive Date:
Collector:
Moisture:
9530-0003-004FS 171772005 TS 12-SEP-06 15-SEP-06 Client 37.6%
Project:
Client ID:
Vol. Recv.:
YANK01204 YANK001 Parameter Qualifier Result Uncertainty LC TPU MDA Units DF Analyst Date Time Batch Mtd Rad Gamma Spec Analysis Gamma,Solid-FSS GAM & ALL FSS 226 Ingrowth Waived Actinium-228 1.57
+/-0.318 Americium-241 U
-0.0262
+/-0.0823 Bismuth-212 0.919
+/-0.411 Bismuth-214 0.951
+/-0.164 Cesium-134 UI 0.00
+/-0.0814 Cesium-137 0.311
+/-0.0725 Cobalt-60 U
0.00424
+/-0.0302 Europium-152 U
-0.0525
+/-0.0822 Europium-154 U
0.0495
+/-0.0944 Europium-155 U
0.065
+/-0.119 Lead-212 1.50
+/-0.155 Lead-214 1.17
+/-0.167 Manganese-54 U
-0.0192
+/-0.0341 Niobium-94 U
0.0174
+/-0.0312 Potassium-40 24.9
+/-1.99 Radium-226 0.951
+/-0.164 Silver-108m U
0.00734
+/-0.0374 Thallium-208 0.467
+/-0.0801 0.0851 0.066 0.265 0.0557 0.037 0.0271 0.0224 0.0667 0.0828 0.0698 0.0389 0.0497 0.0263 0.0263 0.248 0.0557 0.0242 0.0245
+/-0.318
+/-0.0823
+/-0.411
+/-0.164
+/-0.0814
+/-0.0725
+/-0.0302
+/-0.0822
+/-0.0944
+/-0.119
+/-0.155
+/-0.167
+/-0.0341
+/-0.0312
+/-1.99
+/-0.164
+/-0.0374
+/-0.0801 0.183 0.136 0.554 0.117 0.0777 0.0573 0.0497 0.139 0.179 0.144 0.0804 0.104 0.0559 0.0553 0.545 0.117 0.0506 0.0519 pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g MJH1 09/27/06 1301 569469 1
The following Prep Methods were performed Method Description Analyst Date Time Prep Batch Dry Soil Prep Dry Soil Prep GL-RAD-A-021 LXM1 09/15/06 1530 569078 The following Analytical Methods were performed Method Description 1
EML HASL 300, 4.5.2.3 Notes:
The Qualifiers in this report are defined as follows:
A quality control analyte recovery is outside of specified acceptance criteria Result is less than value reported 38
GENERAL ENGINEERING LABORATORIES, LLC 2040 Savage Road Charleston SC 29407 - (843) 556-8171 - www.gel.com Certificate of Analysis Company Connecticut Yankee Atomic Power Address 362 Injun Hollow Rd East Hampton, Connecticut 06424 Report Date: October 3, 2006
Contact:
Mr. Jack McCarthy Project:
Soils PO# 002332 Client Sample ID:
9530-0003-004FS Project:
YANK01204 Sample ID:
171772005 Client ID:
YANK001 Vol. Recv.:
Parameter Qualifier Result Uncertainty LC TPU MDA Units DF Analyst Date Time Batch Mtd Result is greater than value reported A
The TIC is a suspected aldol-condensation product B
Target analyte was detected in the associated blank BD Results are either below the MDC or tracer recovery is low C
Analyte has been confirmed by GC/MS analysis D
Results are reported from a diluted aliquot of the sample H
Analytical holding time was exceeded J
Value is estimated N/A Spike recovery limits do not apply. Sample concentration exceeds spike concentration by 4X or more R
Sample results are rejected U
Analyte was analyzed for, but not detected above the MDL, MDA, or LOD.
UI Gamma Spectroscopy--Uncertain identification X
Consult Case Narrative, Data Summary package, or Project Manager concerning this qualifier Y
QC Samples were not spiked with this compound A
RPD of sample and duplicate evaluated using +/-RL. Concentrations are <5X the RL h
Preparation or preservation holding time was exceeded The above sample is reported on a dry weight basis.
39
GENERAL ENGINEERING LABORATORIES, LLC 2040 Savage Road Charleston SC 29407 - (843) 556-8171 - www.gel.com Certificate of Analysis Company :
Connecticut Yankee Atomic Power Address:
362 Injun Hollow Rd East Hampton, Connecticut 06424
Contact:
Mr. Jack McCarthy Project:
Soils PO# 002332 Report Date: October 3, 2006 Client Sample ID:
Sample ID:
Matrix:
Collect Date:
Receive Date:
Collector:
Moisture:
9530-0003-005F 171772006 TS 12-SEP-06 15-SEP-06 Client 41.2%
Proiect:
Client ID:
Vol. Recv.:
YANKO 1204 YANK001 Parameter Qualifier Result Uncertainty LC TPU MDA Units DF Analyst Date Time Batch Mtd Rad Gamma Spec Analysis Gamma,Solid-FSS GAM & ALL FSS 226 Ingrowth Waived Actinium-228 Americium-241 Bismuth-212 Bismuth-214 Cesium-134 Cesium-137 Cobalt-60 Europium-152 Europium-154 Europium-155 Lead-212 Lead-214 Manganese-54 Niobium-94 Potassium-40 Radium-226 Silver-108m Thallium-208 1.56 U
0.0225 1.13 1.11 UI 0.00 0.487 U
-0.07 U -0.00677 U
-0.0501 U
0.021 1.56 1.07 U
0.0454 U
0.00204 25.7 1.11 U
-0.0102 0.586
+/-0.344
+/-0.0546
+/-0.510
+/-0.190
+/-0.0901
+/-0.0973
+/-0.0493
+/-0.114
+/-0.141
+/-0.0931
+/-0.165
+/-0.167
+/-0.0403
+/-0.0377
+/-1.72
+/-0.190
+/-0.0381
+/-0.0997 0.121 0.0382 0.292 0.0575 0.043 0.0325 0.0344 0.0754 0.111 0.0616 0.0393 0.0536 0.0344 0.0314 0.263 0.0575 0.0261 0.0312
+/-0.344
+/-0.0546
+1-0.510
+/-0.190
+/-0.0901
+/-0.0973
+/-0.0493
+/-0.114
+/-0.141
+/-0.0931
+/-0.165
+/-0.167
+I-0.0403
+I-0.0377
+/-1.72
+1-0.190
+/-0.0381
+/-0.0997 0.243 0.0763 0.584 0.115 0.0859 0.0649 0.0687 0.151 0.222 0.123 0.0785 0.107 0.0687 0.0628 0.525 0.115 0.0521 0.0623 pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCilg pCilg MJHI 09/27/06 1317 569469 1
The following Prep Methods were performed Method Description Analyst Date Time Prep Batch Dry Soil Prep Dry Soil Prep GL-RAD-A-021 LXM1 09/15/06 1530 569078 The following Analytical Methods were performed Method Description I
EML HASL 300, 4.5.2.3 Notes:
The Qualifiers in this report are defined as follows:
A quality control analyte recovery is outside of specified acceptance criteria Result is less than value reported 40
GENERAL ENGINEERING LABORATORIES, LLC 2040 Savage Road Charleston SC 29407 - (843) 556-8171 - www.gel.com Certificate of Analysis Company:
Connecticut Yankee Atomic Power Address :
362 Injun Hollow Rd East Hampton, Connecticut 06424 Report Date: October 3, 2006
Contact:
Mr. Jack McCarthy Project:
Soils PO# 002332 Client Sample ID:
9530-0003-005F Project:
YANK01204 Sample ID:
171772006 Client ID:
YANK001 Vol. Recv.:
Parameter Qualifier Result Uncertainty LC TPU MDA Units DF Analyst Date Time Batch Mtd Result is greater than value reported A
The TIC is a suspected aldol-condensation product B
Target analyte was detected in the associated blank BD Results are either below the MDC or tracer recovery is low C
Analyte has been confirmed by GC/MS analysis D
Results are reported from a diluted aliquot of the sample H
Analytical holding time was exceeded J
Value is estimated N/A Spike recovery limits do not apply. Sample concentration exceeds spike concentration by 4X or more R
Sampleresults are rejected U
Analyte:was analyzed for, but not detected above the MDL, MDA, or LOD.
UI Gamma Spectroscopy--Uncertain identification X
Consult Case Narrative, Data Summary package, or Project Manager concerning this qualifier Y
QC Samples were not spiked with this compound A
RPD of sample and duplicate evaluated using +/-RL. Concentrations are <5X the RL h
Preparation or preservation holding time was exceeded The above sample is reported on a dry weight basis.
41
GENERAL ENGINEERING LABORATORIES, LLC 2040 Savage Road Charleston SC 29407 - (843) 556-8171 - www.gel.corn Certificate of Analysis Company:
Connecticut Yankee Atomic Power Address :
362 Injun Hollow Rd
Contact:
Project:
East Hampton, Connecticut 06424 Mr. Jack McCarthy Soils PO# 002332 Report Date: October 3, 2006 Client Sample ID:
Sample ID:
Matrix:
Collect Date:
Receive Date:
Collector:
Moisture:
9530-0003-006F 171772007 TS 12-SEP-06 15-SEP-06 Client 6.63%
Proiect:
YANK01204 Client ID:
YANK001 Vol. Recv.:
Parameter Qualifier Result Uncertainty LC TPU MDA Units DF Analyst Date Time Batch Mtd Rad Gamma Spec Analysis Gamma,Solid-FSS GAM & ALL FSS 226 Ingrowth Waived Actinium-228 Americium-241 Bismuth-212 Bismuth-214 Cesium-134 Cesium-137 Cobalt-60 Europium-152 Europium-154 Europium-155 Lead-212 Lead-214 Manganese-54 Niobium-94 Potassium-40 Radium-226 Silver-108m Thallium-208 0.494 U
0.0088 0.258 0.413 U
0.0291 0.0957 U
0.00364 U
-0.0176 U-0.000325 U
0.022 0.485 0.395 U
0.0144 U
0.0119 11.1 0.413 U
0.00401 0.148
+/-0.0975
+/-0.0174
+/-0.188
+/-0.0516
+/-0.0242
+/-0.0327
+/-0.0147
+/-0.0326
+/-0.0451
+/-0.0444
+/-0.0377
+/-0.052
+/-0.0201
+/-0.0131
+/-0.634
+/-0.0516
+/-0.0118
+/-0.0308 0.0418 0.0167 0.095 0.0231 0.016 0.0123 0.0126 0.0286 0.0381 0.0283 0.0165 0.0214 0.0112 0.0117 0.127 0.0231 0.0106 0.0119
+/-0.0975
+/-0.0174
+/-0.188
+/-0.0516
+/-0.0242
+/-0.0327
+/-0.0147
+/-0.0326
+/-0.0451
+/-0.0444
+/-0.0377
+/-0.052
+/-0.0201
+/-0.0131
+/-0.634
+/-0.0516
+/-0.0118
+/-0.0308 0.0887 0.0341 0.200 0.0483 0.0334 0.0258 0.0272 0.0595 0.0815 0.0581 0.0341 0.0444 0.0238 0.0246 0.273 0.0483 0.0221 0.0249 pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g MJHl 09/22/06 1825 569469 1
The following Prep Methods were performed Method Description Analyst Date Time Prep Batch Dry Soil Prep Dry Soil Prep GL-RAD-A-021 LXM1 09/15/06 1530 569078 The following Analytical Methods were performed Method Description 1
EML HASL 300, 4.5.2.3 Notes:
The Qualifiers in this report are defimed as follows:
A quality control analyte recovery is outside of specified acceptance criteria Result is less than value reported 42
GENERAL ENGINEERING LABORATORIES, LLC 2040 Savage Road Charleston SC 29407 - (843) 556-8171 - www.gel.com Certificate of Analysis Company:
Connecticut Yankee Atomic Power Address:
362 Injun Hollow Rd East Hampton, Connecticut 06424 Report Date: October 3, 2006
Contact:
Mr. Jack McCarthy Project:
Soils PO# 002332 Client Sample ID:
9530-0003-006F Project:
YANK01204 Sample ID:
171772007 Client ID:
YANK001 Vol. Recv.:
Parameter Qualifier Result Uncertainty LC TPU MDA Units DF Analyst Date Time Batch Mtd Result is greater than value reported A
The TIC is a suspected aldol-condensation product B
Target analyte was detected in the associated blank BD Results are either below the MDC or tracer recovery is low C
Analyte has been confirmed by GC/MS analysis D
Results are reported from a diluted aliquot of the sample H
Analytical holding time was exceeded J
Value is estimated N/A Spike recovery limits do not apply. Sample concentration exceeds spike concentration by 4X or more R
Sample results are rejected U
Analyte was analyzed for, but not detected above the MDL, MDA, or LOD.
UI Gamma Spectroscopy--Uncertain identification X
Consult Case Narrative, Data Summary package, or Project Manager concerning this qualifier Y
QC Samples were not spiked with this compound A
RPD of sample and duplicate evaluated using +/-RL. Concentrations are <5X the RL h
Preparation or preservation holding time was exceeded The above sample is reported on a dry weight basis.
43
GENERAL ENGINEERING LABORATORIES, LLC 2040 Savage Road Charleston SC 29407 - (843) 556-8171 - www.gel.com Certificate of Analysis Company:
Connecticut Yankee Atomic Power Address:
362 Injun Hollow Rd East Hampton, Connecticut 06424
Contact:
Mr. Jack McCarthy Project:
Soils PO# 002332 Report Date: October 3, 2006 Client Sample ID:
Sample ID:
Matrix:
Collect Date:
Receive Date:
Collector:
Moisture:
9530-0003-006FS 171772008 TS 12-SEP-06 15-SEP-06 Client 6.72%
Proiect:
Client ID:
Vol. Recv.:
YANK01204 YANK001 Parameter Qualifier Result Uncertainty LC TPU MDA Units DF Analyst Date Time Batch Mtd Rad Gamma Spec Analysis Gamma,Solid-FSS GAM & ALL FSS 226 Ingrowth Waived Actinium-228 Americium-241 Bismuth-212 Bismuth-214 Cesium-134 Cesium-137 Cobalt-60 Europium-152 Europium-154 Europium-155 Lead-212 Lead-214 Manganese-54 Niobium-94 Potassium-40 Radium-226 Silver-108m Thallium-208 0.502 U
0.00606 U
0.145 0.339 UL 0.00 0.0947 U-0.000735 U
-0.0201 U
0.0304 U
0.0246 0.370 0.375 U
-0.0152 U
0.0172 11.2 0.339 U
0.00459 0.161
+/-0.139
+/-0.0222
+/-0.218
+/-0.0713
+/-0.0256
+/-0.0286
+/-0.0182
+/-0.040
+/-0.0526
+/-0.0362
+/-0.0478
+/-0.0679
+/-0.0184
+/-0.0169
+/-0.641
+/-0.0713
+/-0.0137
+/-0.0404 0.0497 0.0202 0.126 0.0283 0.0179 0.0163 0.0153 0.0336 0.0463 0.032 0.0244 0.0249 0.0147 0.0152 0.129 0.0283 0.0126 0.0142
+/-0.139
+/-0.0222
+/-0.218
+/-0.0713
+/-0.0256
+/-0.0286
+/-0.0182
+/-0.040
+/-0.0526
+/-0.0362
+/-0.0478
+/-0.0679
+/-0.0184
+/-0.0169
+/-0.641
+/-0.0713
+/-0.0137
+1-0.0404 0.105 0.0413 0.261 0.0587 0.0373 0.034 0.0325 0.0696 0.0978 0.0655 0.0498 0.0516 0.0307 0.0314 0.277 0.0587 0.026 0.0296 pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g MJHI 09/22/06 1826 569469 1
The following Prep Methods were performed Method Description Analyst Date Time Prep Batch Dry Soil Prep Dry Soil Prep GL-RAD-A-021 LXM1 09/15/06 1530 569078 The following Analytical Methods were performed Method Description 1
EML HASL 300, 4.5.2.3 Notes:
The Qualifiers in this report are defined as follows:
A quality control analyte recovery is outside of specified acceptance criteria Result is less than value reported 44
GENERAL ENGINEERING LABORATORIES, LLC 2040 Savage Road Charleston SC 29407 - (843) 556-8171 - www.gel.com Certificate of Analysis Company:
Connecticut Yankee Atomic Power Address:
362 Injun Hollow Rd East Hampton, Connecticut 06424 Report Date: October 3, 2006
Contact:
Mr. Jack McCarthy Project:
Soils PO# 002332 Client Sample ID:
9530-0003-006FS Project:
YANK01204 Sample ID:
171772008 Client ID:
YANKOOl Vol. Recv.:
Parameter Qualifier Result Uncertainty LC TPU MDA Units DF Analyst Date Time Batch Mtd Result is greater than value reported A
The TIC is a suspected aldol-condensation product B
Target analyte was detected in the associated blank BD Results are either below the MDC or tracer recovery is low C
Analyte has been confirmed by GC/MS analysis D
Results are reported from a diluted aliquot of the sample H
Analytical holding time was exceeded J
Value is estimated N/A Spike recovery limits do not apply. Sample concentration exceeds spike concentration by 4X or more R
Sample results are rejected U
Analyte was analyzed for, but not detected above the MDL, MDA, or LOD.
UI Gamma'Spectroscopy--Uncertain identification X
Consult Case Narrative, Data Summary package, or Project Manager concerning this qualifier Y
QC Samples were not spiked with this compound A
RPD of sample and duplicate evaluated using +/-RL. Concentrations are <5X the RL h
Preparation or preservation holding time was exceeded The above sample is reported on a dry weight basis.
45
GENERAL ENGINEERING LABORATORIES, LLC 2040 Savage Road Charleston SC 29407 - (843) 556-8171 - www.gel.com Certificate of Analysis Company :
Connecticut Yankee Atomic Power Address:
362 Injun Hollow Rd East Hampton, Connecticut 06424
Contact:
Mr. Jack McCarthy Project:
Soils PO# 002332 Report Date: October 3, 2006 Client Sample ID:
Sample ID:
Matrix:
Collect Date:
Receive Date:
Collector:
Moisture:
9530-0003-007F 171772009 TS 12-SEP-06 15-SEP-06 Client 4.71%
Project:
YANKO01204 Client ID:
YANK001 Vol. Recv.:
Parameter Qualifier Result Uncertainty LC TPU MDA Units DF Analyst Date Time Batch Mtd Rad Gamma Spec Analysis Gamma,Solid-FSS GAM & ALL FSS 226 Ingrowth Waived Actinium-228 0.520
+/-0.0844 Americium-241 U
0.00503
+/-0.0573 Bismuth-212 0.227
+/-0.116 Bismuth-214 0.362
+/-0.0532 Cesium-134 UI 0.00
+/-0.0174 Cesium-137 0.057
+/-0.0155 Cobalt-60 U
0.00905
+/-0.0181 Europium-152 U 0.000663
+/-0.0254 Europium-154 U
-0.0346
+/-0.0308 Europium-155 U
0.028
+/-0.0314 Lead-212 0.502
+/-0.0311 Lead-214 0.402
+/-0.044 Manganese-54 U
0.0139
+/-0.0119 Niobium-94 U
0.00226
+/-0.00891 Potassium-40 12.5
+/-0.500 Radium-226 0.362
+/-0.0532 Silver-108m U-0.000607
+/-0.00859 Thallium-208 0.143
+/-0.0256 0.0294 0.0503 0.0668 0.0165 0.011 0.00945 0.00995 0.0229 0.0247 0.0299 0.0138 0.0154 0.00783
+/-0.0844
+/-0.0573
+/-0.116
+/-0.0532
+/-0.0174
+/-0.0155
+/-0.0181
+/-0.0254
+/-0.0308
+/-0.0314
+/-0.0311
+1-0.044
+/-0.0119 0.0617 0.103 0.139 0.0343 0.0228 0.0196 0.021 0.0474 0.0525 0.0613 0.0283 0.032 0.0164 0.0166 0.178 0.0343 0.0157 0.0166 pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g MJHI 09/22/06 1826 569469 1
0.00799 +/-0.00891 0.0834
+/-0.500 0.0165 +/-0.0532 0.00756 +/-0.00859 0.00795 +/-0.0256 The following Prep Methods were performed Method Description Analyst Date Time Prep Batch Dry Soil Prep Dry Soil Prep GL-RAD-A-021 LXM1 09/15/06 1530 569078 The following Analytical Methods were performed Method Description I
EML HASL 300, 4.5.2.3 Notes:
The Qualifiers in this report are defined as follows:
A quality control analyte recovery is outside of specified acceptance criteria Result is less than value reported 46
GENERAL ENGINEERING LABORATORIES, LLC 2040 Savage Road Charleston SC 29407 - (843) 556-8171 - www.gel.com Certificate of Analysis Company Connecticut Yankee Atomic Power Address:
362 Injun Hollow Rd East Hampton, Connecticut 06424 Report Date: October 3, 2006
Contact:
Mr. Jack McCarthy Project:
Soils PO# 002332 Client Sample ID:
9530-0003-007F Proiect:
YANK01204 Sample ID:
171772009 Client ID:
YANKOOl Vol. Recv.:
Parameter Qualifier Result Uncertainty LC TPU MDA Units DF Analyst Date Time Batch Mtd Result is greater than value reported A
The TIC is a suspected aldol-condensation product B
Target analyte was detected in the associated blank BD Results are either below the MDC or tracer recovery is low C
Analyte has been confirmed by GC/MS analysis D
Results are reported from a diluted aliquot of the sample H
Analytical holding time was exceeded J
Value is estimated N/A Spike recovery limits do not apply. Sample concentration exceeds spike concentration by 4X or more R
Sample results are rejected U
Analyte was analyzed for, but not detected above the MDL, MDA, or LOD.
UI Gamma Spectroscopy--Uncertain identification X
Consult Case Narrative, Data Summary package, or Project Manager concerning this qualifier Y
QC Samples were not spiked with this compound A
RPD of sample and duplicate evaluated using +/-RL. Concentrations are <5X the RL h
Preparation or preservation holding time was exceeded The above sample is reported on a dry weight basis.
47
GENERAL ENGINEERING LABORATORIES, LLC 2040 Savage Road Charleston SC 29407 - (843) 556-8171 - www.gel.com Certificate of Analysis w
i Company :
Connecticut Yankee Atomic Power Address :
362 Injun Hollow Rd East Hampton, Connecticut 06424
Contact:
Mr. Jack McCarthy Project:
Soils PO# 002332 Report Date: October 3, 2006 Client Sample ID:
Sample ID:
Matrix:
Collect Date:
Receive Date:
Collector:
Moisture:
9530-0003-008F 171772010 TS 12-SEP-06 15-SEP-06 Client 35.6%
Proiect:
YANK01204 Client ID:
YANK001 Vol. Recv.:
Parameter Qualifier Result Uncertainty LC TPU MDA Units DF Analyst Date Time Batch Mtd Rad Gamma Spec Analysis Gamma,Solid-FSS GAM & ALL FSS 226 Ingrowth Waived Actinium-228 1.28
+/-0.150 Americium-241 U
-0.0448
+/-0.0654 Bismuth-212 0.865
+/-0.244 Bismuth-214 0.777
+/-0.0788 Cesium-134 UI 0.00
+/-0.0281 Cesium-137 0.289
+/-0.0386 Cobalt-60 U-0.000164
+/-0.018 Europium-152 U
0.00156
+/-0.0443 Europium-154 U
-0.0147
+/-0.0539 Europium-155 U
0.0509
+/-0.0547 Lead-212 1.28
+/-0.0639 Lead-214 0.900
+/-0.0761 Manganese-54 U
0.0205
+/-0.0208 Niobium-94 U
0.00113
+/-0.0161 Potassium-40 20.1
+/-0.774 Radium-226 0.777
+/-0.0788 Silver-108m U
0.00182
+/-0.0152 Thallium-208 0.348
+/-0.0449 0.0465 0.0538 0.0967 0.0291 0.0182 0.0138 0.0146 0.0371 0.0431 0.0461 0.0213 0.0255 0.014 0.0137 0.107 0.0291 0.0126 0.0142
+/-0.150
+/-0.0654
+/-0.244
+/-0.0788
+/-0.0281
+/-0.0386
+/-0.018
+/-0.0443
+/-0.0539
+/-0.0547
+/-0.0639
+/-0.0761
+/-0.0208
+/-0.0161
+/-0.774
+/-0.0788
+/-0.0152
+/-0.0449 0.0976 0.110 0.203 0.0603 0.0377 0.0288 0.0309 0.0766 0.0909 0.0941 0.0437 0.0526 0.0292 0.0284 0.232 0.0603 0.0262 0.0296 pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g MJH1 09/22/06 1827 569469 1
The following Prep Methods were performed Method Description Analyst Date Time Prep Batch Dry Soil Prep Dry Soil Prep GL-RAD-A-021 LXM1 09/15/06 1530 569078 The following Analytical Methods were performed Method Description I
EML HASL 300, 4.5.2.3 Notes:
The Qualifiers in this report are defined as follows:
A quality control analyte recovery is outside of specified acceptance criteria Result is less than value reported 48
GENERAL ENGINEERING LABORATORIES, LLC 2040 Savage Road Charleston SC 29407 - (843) 556-8171 - www.gel.com Certificate of Analysis Company:
Connecticut Yankee Atomic Power Address:
362 Injun Hollow Rd East Hampton, Connecticut 06424 Report Date: October 3, 2006
Contact:
Mr. Jack McCarthy Project:
Soils PO# 002332 Client Sample ID:
9530-0003-008F Project:
YANK01204 Sample ID:
171772010 ClientID:
YANK001 Vol. Recv.:
Parameter Qualifier Result Uncertainty LC TPU MDA Units DF Analyst Date Time Batch Mtd Result is greater than value reported A
The TIC is a suspected aldol-condensation product B
Target analyte was detected in the associated blank BD Results are either below the MDC or tracer recovery is low C
Analyte has been confirmed by GC/MS analysis D
Results are reported from a diluted aliquot of the sample H
Analytical holding time was exceeded J
Value is-estimated N/A Spike recovery limits do not apply. Sample concentration exceeds spike concentration by 4X or more R
Sample results are rejected U
Analyte was analyzed for, but not detected above the MDL, MDA, or LOD.
UI Gamma Spectroscopy--Uncertain identification X
Consult Case Narrative, Data Summary package, or Project Manager concerning this qualifier Y
QC Samples were not spiked with this compound A
RPD of sample and duplicate evaluated using +/-RL. Concentrations are <5X the RL h
Preparation or preservation holding time was exceeded The above sample is reported on a dry weight basis.
49
GENERAL ENGINEERING LABORATORIES, LLC 2040 Savage Road Charleston SC 29407 - (843) 556-8171 - www.gel.com Certificate of Analysis Company:
Connecticut Yankee Atomic Power Address:
362 Injun Hollow Rd East Hampton, Connecticut 06424
Contact:
Mr. Jack McCarthy Project:
Soils PO# 002332 Report Date: October 3, 2006 Client Sample ID:
9530-0003-009F Project:
YANK01204 Sample ID:
171772011 Client ID:
YANKOO Matrix:
TS Vol. Recv.:
Collect Date:
12-SEP-06 Receive Date:
15-SEP-06 Collector:
Client Moisture:
42.4%
Parameter Qualifier Result Uncertainty LC TPU MDA Units DF Analyst Date Time Batch Mtd Rad Gamma Spec Analysis Gamma,Solid-FSS GAM & ALL FSS 226 Ingrowth Waived Actinium-228 1.30
+/-0.331 Americium-241 U
0.0636
+/-0.0573 Bismuth-212 1.01
+/-0.483 Bismuth-214 0.983
+/-0.161 Cesium-134 UI 0.00
+/-0.0632 Cesium-137 0.395
+/-0.0783 Cobalt-60 U
-0.0288
+/-0.0476 Europium-152 U
0.0338
+/-0.125 Europium-154 U
-0.0177
+/-0.146 Europium-155 Ul 0.00
+/-0.105 Lead-212 1.50
+/-0.157 Lead-214 1.19
+/-0.171 Manganese-54 Ul 0.00
+/-0.051 Niobium-94 U
0.00922
+/-0.035 Potassium-40 25.6
+/-1.73 Radium-226 0.983
+/-0.161 Silver-108m U
-0.0361
+/-0.0342 Thallium-208 0.539
+/-0.094 0.113 0.0383 0.248 0.0595 0.0414 0.0364 0.0364 0.071 0.118 0.0581 0.0355 0.0509 0.0333 0.0295 0.337 0.0595 0.0261 0.0272
+/-0.331
+/-0.0573
+/-0.483
+/-0.161
+/-0.0632
+/-0.0783
+/-0.0476
+/-0.125
+/-0.146
+/-0.105
+/-0.157
+/-0.171
+/-0.051
+/-0.035
+/-1.73
+/-0.161
+/-0.0342
+/-0.094 0.225 0.0766 0.496 0.119 0.0827 0.0727 0.0728 0.142 0.235 0.116 0.071 0.102 0.0665 0.059 0.674 0.119 0.0522 0.0544 pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g MJHI 09/22/06 1840 569469 1
The following Prep Methods were performed Method Description Analyst Date Time Prep Batch Dry Soil Prep Dry Soil Prep GL-RAD-A-021 LXMI 09/15/06 1530 569078 The following Analytical Methods were performed Method Description 1
EML HASL 300, 4.5.2.3 Notes:
The Qualifiers in this report are defined as follows:
A quality control analyte recovery is outside of specified acceptance criteria Result is less than value reported 50
GENERAL ENGINEERING LABORATORIES, LLC 2040 Savage Road Charleston SC 29407 - (843) 556-8171 - www.gel.com Certificate of Analysis Company Connecticut Yankee Atomic Power Address:
362 Injun Hollow Rd East Hampton, Connecticut 06424 Report Date: October 3, 2006
Contact:
Mr. Jack McCarthy Project:
Soils PO# 002332 Client Sample ID:
9530-0003-009F Project:
YANKO 1204 SamplelD:
171772011 ClientID:
YANK001 Vol. Recv.:
Parameter Qualifier Result Uncertainty LC TPU MDA Units DF Analyst Date Time Batch Mtd Result is greater than value reported A
The TIC is a suspected aldol-condensation product B
Target analyte was detected in the associated blank BD Results are either below the MDC or tracer recovery is low C
Analyte has been confirmed by GC/MS analysis D
Results are reported from a diluted aliquot of the sample H
Analytical holding time was exceeded J
Value is estimated N/A Spike recovery limits do not apply. Sample concentration exceeds spike concentration by 4X or more R
Sample results are rejected U
Analyte was analyzed for, but not detected above the MDL, MDA, or LOD.
UI Gamma Spectroscopy--Uncertain identification X
Consult Case Narrative, Data Summary package, or Project Manager concerning this qualifier Y
QC Samples were not spiked with this compound A
RPD of sample and duplicate evaluated using +/-RL. Concentrations are <5X the RL h
Preparation or preservation holding time was exceeded The above sample is reported on a dry weight basis.
51
GENERAL ENGINEERING LABORATORIES, LLC 2040 Savage Road Charleston SC 29407 - (843) 556-8171 - www.gel.com Certificate of Analysis Company:
Connecticut Yankee Atomic Power Address:
362 Injun Hollow Rd East Hampton, Connecticut 06424
Contact:
Mr. Jack McCarthy Project:
Soils PO# 002332 Report Date: October 3, 2006 Client Sample ID:
Sample ID:
Matrix:
Collect Date:
Receive Date:
Collector:
Moisture:
9530-0003-010F 171772012 TS 12-SEP-06 15-SEP-06 Client 29.3%
Project:
Client ID:
Vol. Recv.:
YANKO 1204 YANK001 Parameter Qualifier Result Uncertainty LC TPU MDA Units DF Analyst Date Time Batch Mtd Rad Gamma Spec Analysis Gamma,Solid-FSS GAM & ALL FSS 226 Ingrowth Waived Actinium-228 UI 0.00
+/-0.347 Americium-241 U
0.00686
+/-0.0668 Bismuth-212 1.42
+/-0.702 Bismuth-214 UI 0.00
+/-0.214 Cesium-134 U
0.0404
+/-0.0542 Cesium-137 0.287
+/-0.0826 Cobalt-60 U
0.046
+/-0.0581 Europium-152 U
-0.0499
+/-0.134 Europium-154 U
-0.0079
+/-0.148 Europium-155 U
0.131
+/-0.097 Lead-212 1.10
+/-0.154 Lead-214 0.695
+/-0.164 Manganese-54 U
-0.0231
+/-0.0515 Niobium-94 U
0.00586
+/-0.0455 Potassium-40 16.3
+/-1.90 Radium-226 0.759
+/-0.214 Silver-108m U
0.00115
+/-0.0381 Thallium-208 0.338
+/-0.099 0.283 0.0489 0.287 0.159 0.0493 0.0417 0.0535 0.0932 0.120 0.0834 0.0488 0.0713 0.0411 0.0391 0.153 0.0701 0.0316 0.0335
+/-0.347
+/-0.0668
+/-0.702
+/-0.214
+/-0.0542
+/-0.0826
+/-0.0581
+/-0.134
+/-0.148
+/-0.097
+/-0.154
+/-0.164
+/-0.0515
+/-0.0455
+/-1.90
+/-0.214
+/-0.0381
+/-0.099 0.566 0.0977 0.574 0.318 0.0986 0.0833 0.107 0.186 0.240 0.167 0.0975 0.143 0.0821 0.0781 0.307 0.140 0.0631 0.0671 pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g MJHI 09/23/06 1423 569469 1
The following Prep Methods were performed Method Description Analyst Date Time Prep Batch Dry Soil Prep Dry Soil Prep GL-RAD-A-021 LXM1 09/15/06 1530 569078 The following Analytical Methods were performed Method Description 1
EML HASL 300, 4.5.2.3 Notes:
The Qualifiers in this report are defined as follows:
A quality control analyte recovery is outside of specified acceptance criteria Result is less than value reported 52
GENERAL ENGINEERING LABORATORIES, LLC 2040 Savage Road Charleston SC 29407 - (843) 556-8171 - www.gel.com Certificate of Analysis Company:
Connecticut Yankee Atomic Power Address:
362 Injun Hollow Rd East Hampton, Connecticut 06424 Report Date: October 3, 2006
Contact:
Mr. Jack McCarthy Project:
Soils PO# 002332 Client Sample ID:
9530-0003-OIOF Project:
YANK01204 Sample ID:
171772012 ClientID:
YANK001 Vol. Recv.:
Parameter Qualifier Result Uncertainty LC TPU MDA Units DF Analyst Date Time Batch Mtd Result is greater than value reported A
The TIC is a suspected aldol-condensation product B
Target analyte was detected in the associated blank BD Results are either below the MDC or tracer recovery is low C
Analyte has been confirmed by GC/MS analysis D
Results are reported from a diluted aliquot of the sample H
Analytical holding time was exceeded J
Value is estimated N/A Spike recovery limits do not apply. Sample concentration exceeds spike concentration by 4X or more R
Sample results are rejected U
Analyte was analyzed for, but not detected above the MDL, MDA, or LOD.
UI Gamma Spectroscopy--Uncertain identification X
Consult Case Narrative, Data Summary package, or Project Manager concerning this qualifier Y
QC Samples were not spiked with this compound A
RPD of sample and duplicate evaluated using +/-RL. Concentrations are <5X the RL h
Preparation or preservation holding time was exceeded The above sample is reported on a dry weight basis.
53
GENERAL ENGINEERING LABORATORIES, LLC 2040 Savage Road Charleston SC 29407 - (843) 556-8171 - www.gel.com Certificate of Analysis Company:
Connecticut Yankee Atomic Power Address:
362 Injun Hollow Rd East Hampton, Connecticut 06424
Contact:
Mr. Jack McCarthy Project:
Soils PO# 002332 Report Date: October 3, 2006 Client Sample ID:
Sample ID:
Matrix:
Collect Date:
Receive Date:
Collector:
Moisture:
9530-0003-01IF 171772013 TS 12-SEP-06 15-SEP-06 Client 30.7%
Project:
YANK01204 Client ID:
YANK001 Vol. Recv.:
Parameter Qualifier Result Uncertainty LC TPU MDA Units DF Analyst Date Time Batch Mtd Rad Gamma Spec Analysis Gamma,Solid-FSS GAM & ALL FSS 226 Ingrowth Waived Actinium-228 Americium-241 Bismuth-212 Bismuth-214 Cesium-134 Cesium-137 Cobalt-60 Europium-152 Europium-154 Europium-155 Lead-212 Lead-214 Manganese-54 Niobium-94 Potassium-40 Radium-226 Silver-108m Thallium-208 0.998 U
0.00879 0.604 0.753 UI 0.00 0.227 U
0.0132 U
0.017 U-0.000298 UI 0.00 1.02 0.705 U
0.017 U
0.0012 15.0 0.753 U -0.00615 0.351
+/-0.109
+/-0.0156
+/-0.161
+/-0.0574
+/-0.0203
+/-0.0234
+/-0.0129
+/-0.0372
+/-0.0406
+/-0.0401
+/-0.0372
+/-0.0587
+/-0.0151
+/-0.0121
+/-0.553
+/-0.0574
+/-0.0106
+/-0.031 0.0362 0.0137 0.081 0.0187 0.0139 0.0109 0.0112 0.0255 0.0336 0.0222 0.0138 0.0191 0.0102 0.00999 0.0885 0.0187 0.00879 0.00992
+/-0.109
+/-0.0156
+/-0.161
+/-0.0574
+/-0.0203
+/-0.0234
+/-0.0129
+/-0.0372
+/-0.0406
+/-0.0401
+/-0.0372
+/-0.0587
+/-0.0151
+/-0.0121
+/-0.553
+/-0.0574
+/-0.0106
+/-0.031 0.075 0.0278 0.167 0.0384 0.0284 0.0224 0.0235 0.0522 0.070 0.0451 0.0282 0.0389 0.021 0.0206 0.187 0.0384 0.018 0.0204 pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g MJHI 09/24/06 1114 569469 1
The following Prep Methods were performed Method Description Analyst Date Time Prep Batch Dry Soil Prep Dry Soil Prep GL-RAD-A-021 LXM1 09/15/06 1530 569078 The following Analytical Methods were performed Method Description 1
EML HASL 300, 4.5.2.3 Notes:
The Qualifiers in this report are defined as follows:
A quality control analyte recovery is outside of specified acceptance criteria Result is less than value reported 54
GENERAL ENGINEERING LABORATORIES, LLC 2040 Savage Road Charleston SC 29407 - (843) 556-8171 - www.gel.com Certificate of Analysis Company:
Connecticut Yankee Atomic Power Address:
362 Injun Hollow Rd East Hampton, Connecticut 06424 Report Date: October 3, 2006
Contact:
Mr. Jack McCarthy Project:
Soils PO# 002332 Client Sample ID:
9530-0003-01IF Project:
YANK01204 Sample ID:
171772013 Client ID:
YANKOO Vol. Recv.:
Parameter Qualifier Result Uncertainty LC TPU MDA Units DF Analyst Date Time Batch Mtd Result is greater than value reported A
The TIC is a suspected aldol-condensation product B
Target analyte was detected in the associated blank BD Results are either below the MDC or tracer recovery is low C
Analyte has been confirmed by GC/MS analysis D
Results are reported from a diluted aliquot of the sample H
Analytical holding time was exceeded J
Value is estimated N/A Spike recovery limits do not apply. Sample concentration exceeds spike concentration by 4X or more R
Sample results are rejected U
Analyte was analyzed for, but not detected above the MDL, MDA, or LOD.
UI Gamma Spectroscopy--Uncertain identification X
Consult Case Narrative, Data Summary package, or Project Manager concerning this qualifier Y
QC Samples were not spiked with this compound A
RPD of sample and duplicate evaluated using +/-RL. Concentrations are <5X the RL h
Preparation or preservation holding time was exceeded The above sample is reported on a dry weight basis.
55
GENERAL ENGINEERING LABORATORIES, LLC 2040 Savage Road Charleston SC 29407 - (843) 556-8171 - www.gel.com Certificate of Analysis Company:
Connecticut Yankee Atomic Power Address:
362 Injun Hollow Rd East Hampton, Connecticut 06424
Contact:
Mr. Jack McCarthy Project:
Soils PO# 002332 Report Date: October 3, 2006 Client Sample ID:
Sample ID:
Matrix:
Collect Date:
Receive Date:
Collector:
Moisture:
9530-0003-012F 171772014 TS 12-SEP-06 15-SEP-06 Client 36.1%
Project:
Client ID:
Vol. Recv.:
YANK01204 YANKO01 Parameter Qualifier Result Uncertainty LC TPU MDA Units DF Analyst Date Time Batch Mtd Rad Gamma Spec Analysis Gamma,Solid-FSS GAM & ALL FSS 226 Ingrowth Waived Actinium-228 1.20
+/-0.0875 Americium-241 U
-0.0412
+/-0.0648 Bismuth-212 0.890
+/-0.151 Bismuth-214 0.711
+/-0.0555 Cesium-134 UI 0.00
+/-0.0212 Cesium-137 0.319
+/-0.023
,Cobalt-60 U
0.00637
+/-0.0102 Europium-152 U
-0.0168
+/-0.0261 Europium-154 U
0.00798
+/-0.032 Europium-155 UI 0.00
+/-0.0498 Lead-212 1.25
+/-0.0367 Lead-214 0.929
+/-0.0476 Manganese-54 U
0.0167
+/-0.0186 Niobium-94 U
0.0108
+/-0.00913 Potassium-40 20.9
+/-0.498 Radium-226 0.711
+/-0.0555 Silver-108m U
0.00453
+/-0.0088 Thallium-208 0.392
+/-0.0288 0.0271 +/-0.0875 0.0464 +/-0.0648 0.0606
+/-0.151 0.0157 +/-0.0555 0.011 +/-0.0212 0.00845
+/-0.023 0.00884 +/-0.0102 0.0219 +/-0.0261 0.0274
+/-0.032 0.0267 +/-0.0498 0.0125 +/-0.0367 0.0151 +/-0.0476 0.00858 +/-0.0186 0.00802 +/-0.00913 0.0695
+/-0.498 0.0157 +/-0.0555 0.00748 +/-0.0088 0.00773 +/-0.0288 0.0559 0.0941 0.124 0.0322 0.0226 0.0173 0.0183 0.0447 0.0564 0.0541 0.0254 0.0309 0.0176 0.0164 0.145 0.0322 0.0153 0.0158 pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g MJH1 09/24/06 1115 569469 1
The following Prep Methods were performed Method Description Analyst Date Time Prep Batch Dry Soil Prep Dry Soil Prep GL-RAD-A-021 LXM1 09/15/06 1530 569078 The following Analytical Methods were performed Method Description 1
EML HASL 300, 4.5.2.3 Notes:
The Qualifiers in this report are defined as follows:
A quality control analyte recovery is outside of specified acceptance criteria Result is less than value reported 56
GENERAL ENGINEERING LABORATORIES, LLC 2040 Savage Road Charleston SC 29407 - (843) 556-8171 - www.gel.com Certificate of Analysis Company:
Connecticut Yankee Atomic Power Address :
362 Injun Hollow Rd East Hampton, Connecticut 06424 Report Date: October 3, 2006
Contact:
Mr. Jack McCarthy Project:
Soils PO# 002332 Client Sample ID:
9530-0003-012F Project:
YANK01204 Sample ID:
171772014 Client ID:
YANK001 Vol. Recv.:
Parameter Qualifier Result Uncertainty LC TPU MDA Units DF Analyst Date Time Batch Mtd Result is greater than value reported A
The TIC is a suspected aldol-condensation product B
Target analyte was detected in the associated blank BD Results are either below the MDC or tracer recovery is low C
Analyte has been confirmed by GC/MS analysis D
Results are reported from a diluted aliquot of the sample H
Analytical holding time was exceeded J
Value is estimated N/A Spike recovery limits do not apply. Sample concentration exceeds spike concentration by 4X or more R
Sample results are rejected U
Analyte was analyzed for, but not detected above the MDL, MDA, or LOD.
UI Gamma Spectroscopy--Uncertain identification X
Consult Case Narrative, Data Summary package, or Project Manager concerning this qualifier Y
QC Samples were not spiked with this compound A
RPD of sample and duplicate evaluated using +/-RL. Concentrations are <5X the RL h
Preparation or preservation holding time was exceeded The above sample is reported on a dry weight basis.
57
GENERAL ENGINEERING LABORATORIES, LLC 2040 Savage Road Charleston SC 29407 - (843) 556-8171 - www.gel.com Certificate of Analysis Company:
Connecticut Yankee Atomic Power Address:
362 Injun Hollow Rd East Hampton, Connecticut 06424
Contact:
Mr. Jack McCarthy Project:
Soils PO# 002332 Report Date: October 3, 2006 Client Sample ID:
Sample ID:
Matrix:
Collect Date:
Receive Date:
Collector:
Moisture:
9530-0003-013F 171772015 TS 12-SEP-06 15-SEP-06 Client 26.7%
Project:
Client ID:
Vol. Recv.:
YANK01204 YANK001 Parameter Qualifier Result Uncertainty LC TPU MDA Units DF Analyst Date Time Batch Mtd Rad Alpha Spec Analysis Alphaspec Am241, Cm, Solid ALL FSS Americium-241 U-0.
Curium-242 U
Curium-243/244 U
000541
-0.0173
-0.0175
+/-0.129
+/-0.0747
+/-0.166 0.109 0.0458 0.145
+/-0.129
+/-0.0747
+/-0.166 Alphaspec Pu, Solid-ALL FSS Plutonium-238 0.025 Plutonium-239/240
-0.0158 Liquid Scint Pu241, Solid-ALL FSS Plutonium-241 U
4.46 Rad Gamma Spec Analysis Gamma,Solid-FSS GAM & ALL FSS 226 Ingrowth Waived Actinium-228 0.662 Americium-241 U
-0.0011 Bismuth-212 0.508 Bismuth-214 0.426 Cesium-134 UI 0.00 Cesium-137 0.227 Cobalt-60 U
0.00368
+J Europium-152 U
0.0101 Europium-154 U
-0.0158 Europium-155 UI 0.00 Lead-212 0.666 Lead-214 0.469 Manganese-54 U
0.00388 Niobium-94 U
0.00201
+/
Potassium-40 14.9 Radium-226 0.426 Silver-108m U
0.0103
+/
Thallium-208 0.208 Rad Gas Flow Proportional Counting
+/-0.0663 0.0295 +/-0.0664 k/-0.0681 0.0417 +/-0.0681
+/-9.11 7.45
+/-9.12
+/-0.0686
+/-0.0272
+/-0.110
+/-0.038
+/-0.0148 4/-0.0165
/-0.00741
+/-0.019 4/-0.0224 4-0.0301 4/-0.0279
+/-0.0353 4/-0.0109
/-0.00644
+/-0.376
+/-0.038
/-0.00632 4/-0.0193 0.0211 +/-0.0686 0.0243 +/-0.0272 0.0431
+/-0.110 0.0118
+/-0.038 0.00811 +/-0.0148 0.00603 +/-0.0165 0.00623 +/-0.00741 0.0166
+/-0.019 0.0179 +/-0.0224 0.0191 +/-0.0301 0.00939 +/-0.0279 0.0114 +/-0.0353 0.00589 +/-0.0109 0.00564 +/-0.00644 0.0472
+/-0.376 0.0118
+/-0.038 0.00562 +/-0.00632 0.00584 +/-0.0193 0.309 0.189
- 0.381 0.148 0.173 15.6 0.0434 0.0492 0.0887 0.0241 0.0166 0.0124 0.0129 0.0339 0.0371 0.0387 0.0191 0.0233 0.0121 0.0116 0.0988 0.0241 0.0115 0.012 0.0435 14.6 pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g BXLI 09/28/06 0936 569530 1
BXL1 09/28/06 0936 569531 2
DDR1 10/03/06 0858 573310 3
MJHI 09/24/06 1116 569469 5
KSDI 09/28/06 1949 569258 6
ATH2 09/28/06 1001 569133 8
GFPC, Sr9O, solid-ALL FSS Strontium-90 U
0.007
+/-0.0247 0.0203 +/-0.0247 Rad Liquid Scintillation Analysis LSC, Tritium Dist, Solid-HTD2,ALL FSS Tritium U
-6.64
+/-7.74 6.87
+/-7.74 58
GENERAL ENGINEERING LABORATORIES, LLC 2040 Savage Road Charleston SC 29407 - (843) 556-8171 - www.gel.com Certificate of Analysis Company:
Connecticut Yankee Atomic Power Address :
362 Injun Hollow Rd East Hampton, Connecticut 06424
Contact:
Mr. Jack McCarthy Project:
Soils PO# 002332 Report Date:
October 3, 2006 Client Sample ID:
Sample ID:
9530-0003-013F 171772015 Project:
Client ID:
Vol. Recv.:
YANK01204 YANK001 Parameter Qualifier Result Uncertainty LC TPU MDA Units DF Analyst Date Time Batch Mtd Rad Liquid Scintillation Analysis Liquid Scint C14, Solid All, FSS Carbon-14 U
-0.0273 Liquid Scint Fe55, Solid-ALL FSS Iron-55 U
-1.57 Liquid Scint Ni63, Solid-ALL FSS Nickel-63 U
1.66 Liquid Scint Tc99, Solid-ALL FSS Technetium-99 U
0.189
+/-0.0774 0.0653 +/-0.0774 0.133 pCi/g pCi/g
+/-37.6 26.6
+/-37.6 55.7 AXD2 09/28/06 0325 572496 10 MXP1 09/22/06 0523 569145 12 MXPI 09/24/06 1912 569146 13 KXRI 09/24/06 1525 569161 14
+/-7.81 6.51
+/-7.81 13.4 pCi/g
+/-0.275 0.226
+/-0.275 0.466 pCi/g The following Prep Methods were performed Method Description Analyst Date Time Prep Batch Dry Soil Prep Dry Soil Prep GL-RAD-A-021 LXM1 09/15/06 1530 569078 The following Analytical Methods were performed Method Description 1
DOE EML HASL-300, Am-05-RC Modified 2
DOE EML HASL-300, Pu-I1-RC Modified 3
DOE EML HASL-300, Pu-I1-RC Modified 4
DOE EML HASL-300, Pu-lI -RC Modified 5
EML HASL 300, 4.5.2.3 6
EPA 905.0 Modified 7
EPA 905.0 Modified 8
EPA 906.0 Modified 9
EPA 906.0 Modified 10 EPA EERF C-01 Modified 11 EPA EERF C-01 Modified 12 DOE RESL Fe-I, Modified 13 DOE RESL Ni-I, Modified 14 DOE EML HASL-300, Tc-02-RC Modified Surrogate/Tracer recovery Test Recovery %
Acceptable Limits Americium-243 Plutonium-242 Carrier/Tracer Recovery Alphaspec Am241, Cm, Solid ALL Alphaspec Pu, Solid-ALL FSS Liquid Scint Pu241, Solid-ALL FS 80 76 74 (15%-125%)
(15%-125%)
(25%-125%)
59
GENERAL ENGINEERING LABORATORIES, LLC 2040 Savage Road Charleston SC 29407 - (843) 556-8171 - www.gel.com Certificate of Analysis Company:
Connecticut Yankee Atomic Power Address:
362 Injun Hollow Rd East Hampton, Connecticut 06424 Report Date: October 3, 2006
Contact:
Mr. Jack McCarthy Project:
Soils PO# 002332 Client Sample ID:
9530-0003-013F Project:
YANK01204 Sample ID:
171772015 Client ID:
YANK001 Vol. Recv.:
Parameter Qualifier Result Uncertainty LC TPU MDA Units DF Analyst Date Time Batch Mtd Carrier/Tracer Recovery GFPC, Sr90, solid-ALL FSS 68 (25%-125%)
Carrier/Tracer Recovery Liquid Scint Fe55, Solid-ALL FS 59 (15%-125%)
Carrier/Tracer Recovery Liquid Scint Ni63, Solid-ALL FS 59 (25%-125%)
Carrier/Tracer Recovery Liquid Scint Tc99, Solid-ALL FS 77 (15%-125%)
Notes:
The Qualifiers in this report are defined as follows:
A quality control analyte recovery is outside of specified acceptance criteria Result is less than value reported Result is greater than value reported A
The TIC is a suspected aldol-condensation product B
Target analyte was detected in the associated blank BD Results are either below the MDC or tracer recovery is low C
Analyte has been confirmed by GC/MS analysis D
Results are reported from a diluted aliquot of the sample H
Analytical holding time was exceeded J
Value is estimated N/A Spike recovery limits do not apply. Sample concentration exceeds spike concentration by 4X or more R
Sample results are rejected U
Analyte was analyzed for, but not detected above the MDL, MDA, or LOD.
UI Gamma Spectroscopy--Uncertain identification X
Consult Case Narrative, Data Summary package, or Project Manager concerning this qualifier Y
QC Samples were not spiked with this compound A
RPD of sample and duplicate evaluated using +/-RL. Concentrations are <5X the RL h
Preparation or preservation holding time was exceeded The above sample is reported on a dry weight basis.
60
GENERAL ENGINEERING LABORATORIES, LLC 2040 Savage Road Charleston SC 29407 - (843) 556-8171 - www.gel.com Certificate of Analysis Company:
Connecticut Yankee Atomic Power Address :
362 Injun Hollow Rd East Hampton, Connecticut 06424
Contact:
Mr. Jack McCarthy Project:
Soils PO# 002332 Report Date: October 3, 2006 Client Sample ID:
Sample ID:
Matrix:
Collect Date:
Receive Date:
Collector:
Moisture:
9530-0003-014F 171772016 TS 12-SEP-06 15-SEP-06 Client 5.75%
Project:
YANK01204 Client ID:
YANK001 Vol. Recv.:
Parameter Qualifier Result Uncertainty LC TPU MDA Units DF Analyst Date Time Batch Mtd Rad Alpha Spec Analysis Alphaspec Am241, Cm, Solid ALL FSS Americium-241 U
0.0692 Curium-242 U
-0.0115 Curium-243/244 U -7.700E-08
+/-0.210
+/-0.128
+/-0.288 0.145 0.116 0.242
+/-0.210.
+/-0.128
+/-0.288 Alphaspec Pu, Solid-ALL FSS Plutonium-238 Plutonium-239/240 Liquid Scint Pu241, Solid-ALL FSS
'Plutonium-241 U
Rad Gamma Spec Analysis 0.435 0.388 0.629 0.194 0.175 14.5
-0.024
+/-0.0706 0.0517 +/-0.0706 0.0173
+/-0.0688 0.0422 +/-0.0689 6.00
+/-8.55 6.91
+/-8.57 Gamma,Solid-FSS GAM & ALL FSS 226 Ingrowth Waived Actinium-228 0.539
+/-0.137 Americium-241 U
0.00129
+/-0.0906 Bismuth-212 0.548
+/-0.272 Bismuth-214 0.343
+/-0.0725 Cesium-134 U
0.0246
+/-0.025 Cesium-137 0.117
+/-0.0278 Cobalt-60 U
0.00944
+/-0.0153 Europium-152 U
-0.0402
+/-0.0415 Europium-154 U
-0.0221
+/-0.0507 Europium-155 U
0.0604
+/-0.0627 Lead-212 0.483
+/-0.0587 Lead-214 0.368
+/-0.069 Manganese-54 U -0.00496
+/-0.0156 Niobium-94 U
0.0025
+/-0.0143 Potassium-40 12.5
+/-1.07 Radium-226 0.343
+/-0.0725 Silver-108m U -0.00682
+/-0.0134 Thallium-208 0.146
+/-0.0396 Rad Gas Flow Proportional Counting 0.0394 0.0797 0.0956 0.0246 0.0154 0.0139 0.0136 0.0341 0.0405 0.0369 0.020 0.0255 0.0132 0.0126 0.108 0.0246 0.0111 0.0119
+/-0.137
+/-0.0906
+/-0.272
+/-0.0725
+/-0.025
+/-0.0278
+/-0.0153
+/-0.0415
+/-0.0507
+/-0.0627
+/-0.0587
+/-0.069
+/-0.0156
+/-0.0143
+/-1.07
+/-0.0725
+/-0.0134
+/-0.0396 0.0849 0.164 0.203 0.0518 0.0325 0.0293 0.0297 0.0711 0.0875 0.076 0.0413 0.053 0.0279 0.0266 0.240 0.0518 0.0233 0.0252 0.0409 pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g BXL1 09/28/06 0936 569530 1
BXL1 09/28/06 0936 569531 2
DDR1 10/03/06 0914 573310 3
MJHI 09/27/06 1441 569469 5
GFPC, Sr9O, solid-ALL FSS Strontium-90 Rad Liquid Scintillation Analysis U -0.00463
+/-0.0223 0.019 +/-0.0223 KSD1 09/28/06 1949 569258 6
LSC, Tritium Dist, Solid-HTD2,ALL FSS 61
GENERAL ENGINEERING LABORATORIES, LLC 2040 Savage Road Charleston SC 29407 - (843) 556-8171 - www.gel.com Certificate of Analysis Company:
Connecticut Yankee Atomic Power Address :
362 Injun Hollow Rd East Hampton, Connecticut 06424
Contact:
Mr. Jack McCarthy Project:
Soils PO# 002332 Report Date: October 3, 2006 Client Sample ID:
Sample ID:
9530-0003-014F 171772016 Proiect:
Client ID:
Vol. Recv.:
YANK01204 YANK001 Parameter Qualifier Result Uncertainty LC TPU MDA Units DF Analyst Date Time Batch Mtd Rad Liquid Scintillation Analysis LSC, Tritium Dist, Solid-HTD2,ALL FSS Tritium U
Liquid Scint C14, Solid AII, FSS Carbon-14 U
0.0 Liquid Scint Fe55, Solid-ALL FSS Iron-55 U
Liquid Scint Ni63, Solid-ALL FSS Nickel-63 U
0.
Liquid Scint Tc99, Solid-ALL FSS Technetium-99 U
(
-6.8
+/-7.52 6.59
+/-7.52
+/-0.0795 0.0667 +/-0.0795 12.3
+/-36.0 24.7
+/-36.0 0779
+/-5.27 4.42
+/-5.27
).274
+/-0.247 0.200
+/-0.247 13.8 0.136 51.5 9.09 0.412 pCilg pCilg pCilg pCilg pCi/g ATH2 09/28/06 1448 569133 8
AXD2 09/28/06 0622 572496 11 MXPI 09/22/06 0540 569145 13 MXP1 09/24/06 1959 569146 14 KXR1 09/26/06 1832 569161 15 The following Prep Methods were performed Method Description Analyst Date Time Prep Batch Dry Soil Prep Dry Soil Prep GL-RAD-A-021 LXMI 09/15/06 1530 569078 The following Analytical Methods were performed Method Description 1
2 3
4 5
6 7
8 9
10 11 12 13 14 15 16 DOE EML HASL-300, Am-05-RC Modified DOE EML HASL-300, Pu-11-RC Modified DOE EML HASL-300, Pu-I 1-RC Modified DOE EML HASL-300, Pu-11-RC Modified EML HASL 300, 4.5.2.3 EPA 905.0 Modified EPA 905.0 Modified EPA 906.0 Modified EPA 906.0 Modified EPA 906.0 Modified EPA EERF C-01 Modified EPA EERF C-0 1 Modified DOE RESL Fe-1, Modified DOE RESL Ni-I, Modified DOE EML HASL-300, Tc-02-RC Modified DOE EML HASL-300, Tc-02-RC Modified 62
GENERAL ENGINEERING LABORATORIES, LLC 2040 Savage Road Charleston SC 29407 - (843) 556-8171 - www.gel.com Certificate of Analysis Company:
Connecticut Yankee Atomic Power Address:
362 Injun Hollow Rd East Hampton, Connecticut 06424
Contact:
Mr. Jack McCarthy Project:
Soils PO# 002332 Report Date: October 3, 2006 Client Sample ID:
Sample ID:
9530-0003-014F 171772016 Project:
Client ID:
Vol. Recv.:
YANK01204 YANK001 Parameter Qualifier Result Uncertainty LC TPU MDA Units DF Analyst Date Time Batch Mtd Surrogate/Tracer recovery Test Recovery %
Acceptable Limits Americium-243 Plutonium-242 Carrier/Tracer Recovery Carrier/Tracer Recovery Carrier/Tracer Recovery Carrier/Tracer Recovery Carrier/Tracer Recovery Alphaspec Am241, Cm, Solid ALL Alphaspec Pu, Solid-ALL FSS Liquid Scint Pu241, Solid-ALL Fý GFPC, Sr90, solid-ALL FSS Liquid Scint Fe55, Solid-ALL FS Liquid Scint Ni63, Solid-ALL FS Liquid Scint Tc99, Solid-ALL FS 55 73 77 72 71 78 72 (15%-125%)
(15%-125%)
(25%-125%)
(25%-125%)
(15%-125%)
(25%-125%)
(15%-125%)
Notes:
The Qualifiers in this report are defined as follows:
A quality control analyte recovery is outside of specified acceptance criteria Result is less than value reported Result is greater than value reported A
The TIC is a suspected aldol-condensation product B
Target analyte was detected in the associated blank BD Results are either below the MDC or tracer recovery is low C
Analyte has been confirmed by GC/MS analysis D
Results are reported from a diluted aliquot of the sample H
Analytical holding time was exceeded J
Value is estimated N/A Spike recovery limits do not apply. Sample concentration exceeds spike concentration by 4X or more R
Sample results are rejected U
Analyte was analyzed for, but not detected above the MDL, MDA, or LOD.
UI Gamma Spectroscopy--Uncertain identification X
Consult Case Narrative, Data Summary package, or Project Manager concerning this qualifier Y
QC Samples were not spiked with this compound A
RPD of sample and duplicate evaluated using +/-RL. Concentrations are <5X the RL h
Preparation or preservation holding time was exceeded The above sample is reported on a dry weight basis.
63
GENERAL ENGINEERING LABORATORIES, LLC 2040 Savage Road Charleston SC 29407 - (843) 556-8171 - www.gel.com Certificate of Analysis Company:
Connecticut Yankee Atomic Power Address :
362 Injun Hollow Rd East Hampton, Connecticut 06424
Contact:
Mr. Jack McCarthy Project:
Soils PO# 002332 Report Date: October 3, 2006 Client Sample ID:
Sample ID:
Matrix:
Collect Date:
Receive Date:
Collector:
Moisture:
9530-0003-015F 171772017 TS 12-SEP-06 15-SEP-06 Client 22.4%
Project:
Client ID:
Vol. Recv.:
YANK01204 YANK001 Parameter Qualifier Result Uncertainty LC TPU MDA Units DF Analyst Date Time Batch Mtd Rad Gamma Spec Analysis Gamma,Solid-FSS GAM & ALL FSS 226 Ingrowth Waived Actinium-228 0.776
+/-0.196 Americium-241 U
0.00596
+/-0.0776 Bismuth-212 0.599
+/-0.231 Bismuth-214 0.560
+/-0.0913 Cesium-134 UI 0.00
+/-0.0275 Cesium-137 0.163
+/-0.0363 Cobalt-60 U
0.00301
+/-0.0242 Europium-152 U
-0.0258
+/-0.064
'Europium-154 U
-0.0311
+/-0.0745 Europium-155 U
-0.0301
+/-0.0592 Lead-212 0.848
+/-0.091 Lead-214 0.701
+/-0.100 Manganese-54 U
0.0193
+/-0.0233 Niobium-94 U
0.0119
+/-0.0241 Potassium-40 15.1
+/-1.29 Radium-226 0.560
+/-0.0913 Silver-108m U
0.00264
+/-0.0198 Thallium-208 0.271
+/-0.0492 0.0691 0.0566 0.155 0.0332 0.0232 0.0181 0.0201 0.0474 0.0589 0.0476 0.0269 0.0347 0.0205 0.0183 0.160 0.0332 0.0165 0.0173
+/-0.196
+/-0.0776
+/-0.231
+/-0.0913
+/-0.0275
+/-0.0363
+/-0.0242
+/-0.064
+/-0.0745
+/-0.0592
+/-0.091
+/-0.100
+/-0.0233
+/-0.0241
+/-1.29
+/-0.0913
+/-0.0198
+/-0.0492 0.138 0.113 0.309 0.0663 0.0463 0.0361 0.0402 0.0947 0.118 0.0952 0.0538 0.0693 0.0411 0.0366 0.320 0.0663 0.0331 0.0346 pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g MJH1 09/27/06 1456 569469 1
The following Prep Methods were performed Method Description Analyst Date Time Prep Batch Dry Soil Prep Dry Soil Prep GL-RAD-A-021 LXM1 09/15/06 1530 569078 The following Analytical Methods were performed Method Description 1
EML HASL 300, 4.5.2.3 Notes:
The Qualifiers in this report are defined as follows:
A quality control analyte recovery is outside of specified acceptance criteria Result is less than value reported 64
GENERAL ENGINEERING LABORATORIES, LLC 2040 Savage Road Charleston SC 29407 - (843) 556-8171 - www.gel.com Certificate of Analysis Company:
Connecticut Yankee Atomic Power Address:
362 Injun Hollow Rd East Hampton, Connecticut 06424 Report Date: October 3, 2006
Contact:
Mr. Jack McCarthy Project:
Soils PO# 002332 Client Sample ID:
9530-0003-015F Project:
YANK01204 Sample ID:
171772017 Client ID:
YANK001 Vol. Recv.:
Parameter Qualifier Result Uncertainty LC TPU MDA Units DF Analyst Date Time Batch Mtd Result is greater than value reported A
The TIC is a suspected aldol-condensation product B
Target analyte was detected in the associated blank BD Results are either below the MDC or tracer recovery is low C
Analyte has been confirmed by GC/MS analysis D
Results are reported from a diluted aliquot of the sample H
Analytical holding time was exceeded J
Value is estimated N/A Spike recovery limits do not apply. Sample concentration exceeds spike concentration by 4X or more R
Sample results are rejected U
Analyte was analyzed for, but not detected above the MDL, MDA, or LOD.
UI Gamma Spectroscopy--Uncertain identification X
Consult Case Narrative, Data Summary package, or Project Manager concerning this qualifier Y
QC Samples were not spiked with this compound A
RPD of sample and duplicate evaluated using +/-RL. Concentrations are <5X the RL h
Preparation or preservation holding time was exceeded The above sample is reported on a dry weight basis.
65
GENERAL ENGINEERING LABORATORIES, LLC 2040 Savage Road Charleston SC 29407 - (843) 556-8171 - www.gel.com Certificate of Analysis Company:
Connecticut Yankee Atomic Power Address:
362 Injun Hollow Rd East Hampton, Connecticut 06424
Contact:
Mr. Jack McCarthy Project:
Soils PO# 002332 Report Date: October 3, 2006 Client Sample ID:
Sample ID:
Matrix:
Collect Date:
Receive Date:
Collector:
Moisture:
9530-0003-016F 171772018 TS 12-SEP-06 15-SEP-06 Client 7.46%
Project:
Client ID:
Vol. Recv.:
YANK01204 YANK001 Parameter Qualifier Result Uncertainty LC TPU MDA Units DF Analyst Date Time Batch Mtd Rad Gamma Spec Analysis Gamma,Solid-FSS GAM & ALL FSS 226 Ingrowth Waived Actinium-228 0.596
+/-0.156 Americium-241 U
-0.0717
+/-0.122 Bismuth-212 U
0.167
+/-0.152 Bismuth-214 0.317
+/-0.0736 Cesium-134 U
0.0283
+/-0.0283 Cesium-137 0.0917
+/-0.0302 Cobalt-60 U
0.0111
+/-0.0164
-Europium-152 U
-0.0239
+/-0.0474 Europium-154 U
0.00756
+/-0.0564 Europium-155 U
0.0333
+/-0.0538 Lead-212 0.500
+/-0.0642 Lead-214 0.304
+/-0.0764 Manganese-54 U
0.00535
+/-0.0161 Niobium-94 U
0.00382
+/-0.015 Potassium-40 11.6
+/-1.10 Radium-226 0.317
+/-0.0736 Silver-108m U
-0.0121
+/-0.0154 Thallium-208 0.173
+/-0.0457 0.0516 0.0949 0.144 0.0266 0.0194 0.015 0.0152 0.0404 0.0482 0.0486 0.0232 0.0292 0.0145 0.0135 0.110 0.0266 0.0125 0.0141
+/-0.156
+/-0.122
+/-0.152
+/-0.0736
+/-0.0283
+/-0.0302
+/-0.0164
+/-0.0474
+/-0.0564
+/-0.0538
+/-0.0642
+/-0.0764
+/-0.0161
+/-0.015
+/-1.10
+/-0.0736
+/-0.0154
+/-0.0457 0.112 0.196 0.305 0.0571 0.0415 0.0323 0.0339 0.085 0.106 0.101 0.0483 0.0615 0.0314 0.0291 0.255 0.0571 0.0267 0.0303 pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g MJHI 09/25/06 0536 569469 1
The following Prep Methods were performed Method Description Analyst Date Time Prep Batch Dry Soil Prep Dry Soil Prep GL-RAD-A-021 LXMI 09/15/06 1530 569078 The following Analytical Methods were performed Method Description I
EML HASL 300, 4.5.2.3 Notes:
The Qualifiers in this report are defined as follows:
A quality control analyte recovery is outside of specified acceptance criteria Result is less than value reported 66
GENERAL ENGINEERING LABORATORIES, LLC 2040 Savage Road Charleston SC 29407 - (843) 556-8171 - www.gel.com Certificate of Analysis Company:
Connecticut Yankee Atomic Power Address :
362 Injun Hollow Rd East Hampton, Connecticut 06424 Report Date: October 3, 2006
Contact:
Mr. Jack McCarthy Project:
Soils PO# 002332 Client Sample ID:
9530-0003-016F Project:
YANK01204 Sample ID:
171772018 Client ID:
YANK001 Vol. Recv.:
Parameter Qualifier Result Uncertainty LC TPU MDA Units DF Analyst Date Time Batch Mtd Result is greater than value reported A
The TIC is a suspected aldol-condensation product B
Target analyte was detected in the associated blank BD Results are either below the MDC or tracer recovery is low C
Analyte has been confirmed by GC/MS analysis D
Results are reported from a diluted aliquot of the sample H
Analytical holding time was exceeded J
Value is estimated N/A Spike recovery limits do not apply. Sample concentration exceeds spike concentration by 4X or more R
Sample results are rejected U
Analyte was analyzed for, but not detected above the MDL, MDA, or LOD.
UI Gamma Spectroscopy--Uncertain identification X
Consult Case Narrative, Data Summary package, or Project Manager concerning this qualifier Y
QC Samples were not spiked with this compound A
RPD of sample and duplicate evaluated using +/-RL. Concentrations are <5X the RL h
Preparation or preservation holding time was exceeded The above sample is reported on a dry weight basis.
67
Fr QUALITY CONTROL DATA 68
GENERAL ENGINEERING LABORATORIES, LLC 2040 Savage Road Charleston SC 29407 - (843) 556-8171 - www.gel.com QC Summary Client:
Connecticut Yankee Atomic Power 362 Injun Hollow Rd Report Date: October 3, 2006 Page 1 of 9 East Hampton, Connecticut
Contact:
Mr. Jack McCarthy Workorder:
171772 Parmname NOM Sample Qual QC Units RPD%
REC%
Range Anist Date Time Rad Alpha Spec Batch 569530 QC1201185573 Americium-241 Curium-242 Curium-243/244 QC1201185575 Americium-241 Curium-242 Curium-243/244 QCI201185572 Americium-241 171772015 DUP U
-0.000541 Uncert:
+/-0.129 TPU:
+/-0.129 U
-0.0173 Uncert:
+/-0.0747 TPU:
+/-0.0747 U
-0.0175 Uncert:
+/-0.166 TPU:
+/-0.166 LCS MB 13.6 Uncert:
TPU:
Uncert:
TPU:
16.4 Uncert:
TPU:
Uncert:
TPU:
Uncert:
TPU:
Uncert:
TPU:
U
-0.0675
+/-0.0888
+/-0.0892 U
-0.0429
+/-0.0376
+/-0.038 U
0.0107
+/-0.205
+/-0.205 14.8
+/-1.43
+/-2.33 U
-0.0177
+/-0.0246
+/-0.0247 17.8
+/-1.57
+/-2.71 U
-0.00771
+/-0.119
+/-0.119 U
0.00
+/-0.0748
+/-0.0748 U
-0.148
+/-0.107
+/-0.108 pCi/g 197 pCi/g 85 pCi/g 829 (0% - 100%) BXLI (0%- 100%)
(0%- 100%)
Curium-242 Curium-243/244 QC1201185574 171772015 MS Americium-241 Curium-242 Curium-243/244 pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g 109 (75%-125%)
109 (75%-125%)
09/28/06 09:36 09/29/06 09:15 09/28/06 09:36 13.9 U
-0.000541 Uncert:
+/-0.129 TPU:
+/-0.129 U
-0.0173 Uncert:
+/-0.0747 TPU:
+/-0.0747 16.8 U
-0.0175 Uncert:
+/-0.166 TPU:
+/-0.166 U
14.3
+/-1.31
+/-2.15 0.0439
+/-0.120
+/-0.120 16.9
+/-1.43
+/-2.47 103 (75%-125%)
09/28/06 09:36 101 (75%-125%)
Batch 569531 QC1201185577 171772015 DUP Plutonium-238 0.025
-0.0118 pCi/g 558 (0% - 100%) BXLI 09/28/06 09:36 69
GENERAL ENGINEERING LABORATORIES, LLC 2040 Savage Road Charleston SC 29407 - (843) 556-8171 - www.gel.com QC Summary Workorder:
171772 Page 2 of 9 Parmname NOM Sample Qual QC Units RPD%
REC%
Range AnIst Date Time Rad Alpha Spec Batch 569531 Plutonium-239/240 QC1201185579 LCS Plutonium-238 Plutonium-239/240 QC1201185576 MB Plutonium-238 Plutonium-239/240 QC1201185578 171772015 MS Plutonium-238 Uncert:
+/-0.0663 TPU:
+/-0.0664
-0.0158 Uncert:
+/-0.0681 TPU:
+/-0.0681 Uncert:
TPU:
12.6 Uncert:
TPU:
Uncert:
TPU:
Uncert:
TPU:
Uncert:
TPU:
12.8 Uncert:
TPU:
+/-0.0611
+/-0.0611
-0.00644
+/-0.0541
+/-0.0542
-0.0177
+/-0.052
+/-0.0521 12.3
+/-1.08
+/-1.73
-0.0118
+/-0.0509
+/-0.051 0.0128
+/-0.0509
+/-0.0509 0.0538
+/-0.122
+/-0.122 13.8
+/-1.49
+/-2.28 pCi/g 84 pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g (0%- 100%)
(75%-125%)
09/28/06 09:36 98 (75%-125%)
(75%-125%)
108 (75%-125%)
09/28/06 09:36 0.025
+/-0.0663
+/-0.0664
-0.0158
+/-0.0681
+/-0.0681 09/28/06 09:36 Plutonium-239/240 Batch 573310 QC1201194063 171772015 DUP Plutonium-241 QC1201194065 LCS Plutonium-241 QCI201194062 MB Plutonium-241 QC1201194064 171772015 MS Plutonium-241 Rad Gamma Spec Batch 569469 QC1201185432 171772001 DUP Actinium-228 U
4.46 Uncert:
+/-9.11 TPU:
+/-9.12 U
4.13
+/-8.44
+/-8.45 pCi/g 0
(0% - 100%) DDR1 142 Uncert:
TPU:
Uncert:
TPU:
146 U
Uncert:
TPU:
116
+/-12.4
+/-17.6 U
-0.714
+/-6.51
+/-6.51 pCilg pCi/g PCi/g 81 (75%-125%)
10/03/06 09:47 10/03/06 10:19 10/03/06 09:31 10/03/06 10:03 4.46
+/-9.11
+/-9.12 140
+/-13.3
+/-20.0 96 (75%-125%)
1.00
+/-0.199 Uncert:
0.722
+/-0.187
+/-0.187 pCi/g 4
(0% - 100%) MJH1 09/25/06 05:37 70
GENERAL ENGINEERING LABORATORIES, LLC 2040 Savage Road Charleston SC 29407 - (843) 556-8171 - www.gel.com QC Summary Workorder:
1*1 '7 Page 3 of 9 Parmname NOM Sample Qual QC Units RPD%
REC%
Range AnIst Date Time Rad Gamma Spec Batch 569469 Americium-241 Bismuth-212 Bismuth-214 Cesium-134 Cesium-137 Cobalt-60 Europium-152 Europium-154 Europium-155 TPU:
+/-0.199 u
0.0354 Uncert:
+/-0.071 TPU:
+/-0.071 0.465 Uncert:
+/-0.287 TPU:
+/-0.287 0.531 Uncert:
+/-0.104 TPU:
+/-0.104 u
0.0412 Uncert:
+/-0.0379 TPU:
+/-0.0379 0.141 Uncert:
+/-0.0362 TPU:
+/-0.0362 U -3.370E-05 Uncert:
+/-0.0257 TPU:
+/-0.0257 U
0.0209 Uncert:
+/-0.0776 TPU:
+/-0.0776 U
-0.0547 Uncert:
+/-0.0796 TPU:
+/-0.0796 U
0.111 Uncert:
+/-0.0802 TPU:
+/-0.0802 0.766 Uncert:
+/-0.0868 TPU:
+/-0.0868 0.545 Uncert:
+/-0.0993 TPU:
+/-0.0993 U
-0.00902 Uncert:
+/-0.0261 TPU:
+/-0.0261 U
-0.00508 Uncert:
+/-0.0217 TPU:
+/-0.0217 15.0 Uncert:
+/-1.36 TPU:
+/-1.36 0.531 Uncert:
+/-0.104 TPU:
+/-0.104 U
-0.013 Uncert:
+/-0.0226 U
0.0458
+/-0.0896
+/-0.0896 0.617
+/-0.321
+/-0.321 0.575
+/-0.104
+/-0.104 UI 0.00
+/-0.0429
+/-0.0429 0.141
+/-0.0559
+/-0.0559 U
0.000692
+/-0.022
+/-0.022 U
0.00935
+/-0.0601
+/-0.0601 U
0.0125
+/-0.0628
+/-0.0628 U
0.0817
+/-0.0702
+/-0.0702 0.724
+/-0.0689
+/-0.0689 0.554
+/-0.0931
+/-0.0931 U
0.000707
+/-0.0208
+/-0.0208 U
-0.0114
+/-0.0204
+/-0.0204 15.1
+/-1.03
+/-1.03 0.575
+/-0.104
+/-0.104 U
-0.00982
+/-0.0211 pCi/g 618 pCi/g 8
pCi/g 18 pCi/g 87 pCi/g 10 pCi/g 143 pCi/g 332 pCi/g 101 pCi/g 57 pCi/g 2
pCi/g 18 pCi/g 246 pCi/g 16 pCi/g 0
pCi/g 18 pCi/g 53 (0%- 100%)
(0%- 100%)
(0%- 100%)
(0%- 100%)
(0% - 100%)
(0%- 100%)
(0%- 100%)
(0% - 100%)
(0% - 100%)
(0% - 20%)
(0%-20%)
(0%- 100%)
(0% - 100%)
(0% - 20%)
(0%- 100%)
(0% - 100%)
Lead-212 Lead-214 Manganese-54 Niobium-94 Potassium-40 Radium-226 Silver-108m 71
GENERAL ENGINEERING LABORATORIES, LLC 2040 Savage Road Charleston SC 29407 - (843) 556-8171 - www.gel.com QC Summary Workorder:
171772 Page 4 of 9 Parmname NOM Sample Qual QC Units RPD%
REC%
Range Anlst Date Time Rad Gamma Spec Batch 569469 Thallium-208 TPU:
+/-0.0226 0.272 Uncert:
+/-0.0562 TPU:
+/-0.0562
+/-0.0211 0.208
+/-0.0503
+/-0.0503 pCi/g 15 (0%- 100%)
QC1201185433 Actinium-228 Americium-241 LCS Bismuth-212 Bismuth-214 Cesium-134 Cesium-137 Cobalt-60 Europium-152 Europium-154 Europium-155 Uncert:
TPU:
23.4 Uncert:
TPU:
Uncert:
TPU:
Uncert:
TPU:
Uncert:
TPU:
9.57 Uncert:
TPU:
14.4 Uncert:
TPU:
Uncert:
TPU:
Uncert:
TPU:
Uncert:
TPU:
Uncert:
TPU:
Uncert:
TPU:
Uncert:
TPU:
Uncert:
TPU:
U
-0.838
+/-0.784
+/-0.784 25.6
+/-2.11
+/-2.11 U
0.183
+/-1.39
+/-1.39 U
0.369
+/-0.315
+/-0.315 U
0.0523
+/-0.192
+/-0.192 10.5
+/-1.13
+/-1.13 15.4
+/-0.863
+/-0.863 U
-0.304
+/-0.351
+/-0.351 U
-0.157
+/-0.376
+/-0.376 U
0.205
+/-0.314
+/-0.314 U
0.228
+/-0.303
+/-0.303 U
0.110
+/-0.266
+/-0.266 U
-0.122
+/-0.171
+/-0.171 U
-0.0594
+/-0.160
+/-0.160 U
0.0985 pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g 110 (75%-125%)
107 (75%-125%)
109 (75%-125%)
09/22/06 08:36 Lead-212 Lead-214 Manganese-54 Niobium-94 Potassium-40 72
GENERAL ENGINEERING LABORATORIES, LLC 2040 Savage Road Charleston SC 29407 - (843) 556-8171 - www.gel.com QC Summary Workorder:
171772 Page 5 of 9 Parmname NOM Sample Qual QC Units RPD%
REC%
Range Anist Date Time Rad Gamma Spec Batch 569469 Radium-226 Silver-108m Thallium-208 QC1201185431 Actinium-228 Americium-241 MB Bismuth-212 Bismuth-214 Cesium-134 Cesium-137 Uncert:
TPU:
Uncert:
TPU:
Uncert:
TPU:
Uncert:
TPU:
Uncert:
TPU:
Uncert:
TPU:
Uncert:
TPU:
Uncert:
TPU:
Uncert:
TPU:
Uncert:
TPU:
Uncert:
TPU:
Uncert:
TPU:
Uncert:
TPU:
Uncert:
TPU:
Uncert:
TPU:
Uncert:
TPU:
+/-1.24
+/-1.24 U
0.369
+/-0.315
+/-0.315 U
-0.103
+/-0.150
+/-0.150 U
0.144
+/-0.164
+/-0.164 U
0.0375
+/-0.0692
+/-0.0692 U
0.0538
+/-0.0833
+/-0.0833 U
-0.0346
+1-0.141
+/-0.141 UI 0.00
+/-0.0602
+/-0.0602 U
0.0208
+/-0.0236
+/-0.0236 U
0.00464
+/-0.0268
+/-0.0268 U
0.00218
+/-0.0182
+/-0.0182 U
-0.0209
+/-0.0493
+/-0.0493 U
0.00015
+/-0.0476
+/-0.0476 U
-0.027
+/-0.0446
+/-0.0446 U
0.0118
+/-0.0464
+/-0.0464 U
0.0415
+/-0.0405
+/-0.0405 pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g 09/25/06 05:36 (75%-125%)
Cobalt-60 Europium-152 Europium-154 Europium-155 Lead-212 Lead-214 73
GENERAL ENGINEERING LABORATORIES, LLC 2040 Savage Road Charleston SC 29407 - (843) 556-8171 - www.gel.com QC Summary Workorder:
171772 Page 6 of 9 Parmname NOM Sample Qual QC Units RPD%
REC%
Range Anlst Date Time Rad Gamma Spec Batch 569469 Manganese-54 Niobium-94 Potassium-40 Radium-226 Silver-108m Uncert:
TPU:
Uncert:
TPU:
Uncert:
TPU:
Uncert:
TPU:
Uncert:
TPU:
Uncert:
TPU:
U 0.00295
+/-0.0172
+/-0.0172 U
0.00439
+/-0.0183
+/-0.0183 U
0.210
+/-0.270
+/-0.270 UI 0.00
+/-0.0602
+/-0.0602 U
0.00855
+/-0.0151
+/-0.0151 U
0.0198
+/-0.0186
+/-0.0186 pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g Thallium-208 Rad Gas Flow Batch 569258 QC1201184956 171772015 DUP Strontium-90 QC1201184958 LCS Strontium-90 QC1201184955 MB Strontium-90 QC1201184957 171772015 MS Strontium-90 U
0.007 Uncert:
+/-0.0247 TPU:
+/-0.0247 U
-0.0101
+/-0.0253
+/-0.0253 5.39
+/-0.401
+/-0.421 pCi/g 0
(0% - 100%) KSD1 5.21 Uncert:
TPU:
Uncert:
TPU:
5.22 U
Uncert:
TPU:
U
-0.00432
+/-0.020
+/-0.020 pCi/g pCi/g pCi/g 103 (75%-125%)
09/28/06 19:49 09/28/06 19:49 09/28/06 19:49 09/28/06 19:49 0.007
+/-0.0247
+/-0.0247 4.60
+/-0.365
+/-0.384 88 (75%-125%)
Rad Liquid Scintillation Batch 569133 QC1201184635 171772015 DUP Tritium U
-6.64 Uncert:
+/-7.74 TPU:
+/-7.74 U
QC1201184637 LCS Tritium QC1201184634 MB Tritium
-3.93
+/-8.06
+/-8.06 67.3
+/-13.0
+/-13.0 pCi/g 0
(0% - 100%) ATH2 09/28/06 11:06 66.2 Uncert:
TPU:
pCi/g 102 (75%-125%)
09/23/06 05:38 09/28/06 10:44 U
-7.78 pCi/g 74
GENERAL ENGINEERING LABORATORIES, LLC 2040 Savage Road Charleston SC 29407 - (843) 556-8171 - www.gel.com QC Summary Workorder:
171772 Page 7 of 9 Parmname NOM Sample Qual QC Units RPD%
REC%
Range AnIst Date Time Rad Liquid Scintillation Batch 569133 QC1201184636 171772015 MS Tritium Uncert:
TPU:
66.2 Uncert:
TPU:
+/-7.70
+/-7.70 56.6
+/-13.2
+/-13.2
-0.387
+/-8.81
+/-8.81 pCi/g 86 (75%-125%)
09/23/06 05:22 Batch 569145 QC1201184671 171772016 DUP Iron-55 QC1201184673 LCS Iron-55 QC1201184670 MB Iron-55 QC1201184672 171772016 MS Iron-55 Uncert:
TPU:
U 12.3
+/-36.0
+/-36.0 U
-23.8
+/-34.8
+/-34.8 pCi/g 0
(0% - 100%) VIXPi 667 Uncert:
TPU:
Uncert:
TPU:
671 U
Uncert:
TPU:
615
+/-54.9
+/-68.1 U
-4.53
+/-75.9
+/-75.9 pCi/g pCi/g pCi/g 92 (75%-125%)
09/22/06 06:54 09/22/06 07:26 09/22/06 05:56 09/22/06 07:10 12.3
+/-36.0
+/-36.0 631
+/-49.3
+/-64.6 94 (75%-125%)
Batch 569146 QC1201184675 171772016 DUP Nickel-63 QC1201184677 LCS Nickel-63 QCI1201184674 MB Nickel-63 QC1201184676 171772016 MS Nickel-63 U
0.0779 Uncert:
+/-5.27 TPU:
+/-5.27 U
-4.22
+/-6.00
+/-6.00 pCi/g 0
(0% - 100%) \\IXP1 512 Uncert:
TPU:
Uncert:
TPU:
594 U
Uncert:
TPU:
442
+/-13.7
+/-19.7 U
-3.65
+/-6.37
+/-6.37 pCi/g pCi/g pCi/g 86 (75%-125%)
09/24/06 21:33 09/24/06 23:07 09/24/06 20:46 09/24/06 22:20 0.0779
+/-5.27
+/-5.27 519
+/-15.0
+/-23.3 87 (75%-125%)
Batch 569161 QC1201184720 171772015 DUP Technetium-99 QC1201184722 LCS Technetium-99 U
0.189 Uncert:
+/-0.275 TPU:
+/-0.275 13.0 Uncert:
TPU:
U 0.445
+/-0.294
+/-0.294 12.9
+/-0.508
+/-0.586 pCi/g 0
(0% - 100%) KXR1 09/24/06 16:14 09/24/06 16:46 pCi/g 99 (75%-125%)
75
GENERAL ENGINEERING LABORATORIES, LLC 2040 Savage Road Charleston SC 29407 - (843) 556-8171 - www.gel.com QC Summary Workorder:
171772 Page 8 of 9 Parmname NOM Sample Qual QC Units RPD%
REC%
Range AnIst Date Time Rad Liquid Scintillation Batch 569161 QC1201184719 MB Technetium-99 Uncert:
TPU:
U 0.338
+/-0.251
+/-0.252 pCi/g pCi/g 09/24/06 15:57 09/24/06 16:30 QC1201184721 171772015 MS Technetium-99 13.0 U
Uncert:
TPU:
0.189
+/-0.275
+/-0.275 Batch 572496 QC1201192246 171772015 DUP Carbon-14 QC1201192248 LCS Carbon-14 QC1201192245 MB Carbon-14 QC1201192247
- 171772015 MS Carbon-14 U
-0.0273 Uncert:
+/-0.0774 TPU:
+/-0.0774 U
12.8
+/-0.573
+/-0.643 0.0142
+/-0.121
+/-0.121 7.60
+/-0.320
+/-0.341 99 (75%-125%)
pCi/g 0
(0%- 100%) AXD2 09/28/06 09:42 6.68 Uncert:
TPU:
Uncert:
TPU:
31.2 U
Uncert:
TPU:
U
-0.0388
+/-0.0777
+/-0.0777 pCi/g pCi/g pCi/g 114 (75%-125%)
09/28/06 10:26 09/28/06 07:55 09/28/06 10:04
-0.0273
+/-0.0774
+/-0.0774 36.5
+/-1.51
+/-1.61 117 (75%-125%)
Notes:
The Qualifiers in this report are defined as follows:
A B
BD C
D H
J N/A R
U UI X
Y A quality control analyte recovery is outside of specified acceptance criteria Result is less than value reported Result is greater than value reported The TIC is a suspected aldol-condensation product Target analyte was detected in the associated blank Results are either below the MDC or tracer recovery is low Analyte has been confirmed by GC/MS analysis Results are reported from a diluted aliquot of the sample Analytical holding time was exceeded Value is estimated Spike recovery limits do not apply. Sample concentration exceeds spike concentration by 4X or more Sample results are rejected Analyte was analyzed for, but not detected above the MDL, MDA, or LOD.
Gamma Spectroscopy--Uncertain identification Consult Case Narrative, Data Summary package, or Project Manager concerning this qualifier QC Samples were not spiked with this compound RPD of sample and duplicate evaluated using +/-RL. Concentrations are <5X the RL 76
GENERAL ENGINEERING LABORATORIES, LLC 2040 Savage Road Charleston SC 29407 - (843) 556-8171 - www.gel.com QC Summary Workorder:
171772 Page 9 of 9 Parmname NOM Sample Qual QC Units RPD%
REC%
Range AnIst Date Time A
h Preparation or preservation holding time was exceeded N/A indicates that spike recovery limits do not apply when sample concentration exceeds spike conc. by a factor of 4 or more.
- Indicates analyte is a surrogate compound.
A The Relative Percent Difference (RPD) obtained from the sample duplicate (DUP) is evaluated against the acceptence criteria when the sample is greater than five times (5X) the contract required detection limit (RL). In cases where either the sample or duplicate value is less than 5X the RL, a control limit of +/- the RL is used to evaluate the DUP result.
For PS, PSD, and SDILT results, the values listed are the measured amounts, not final concentrations.
Where the analytical method has been performed under NELAP certification, the analysis has met all of the requirements of the NELAC standard unless qualified on the QC Summary.
77
CENTRAL PENINSULA SURVEY UNIT 9530-0003 RELEASE RECORD ATTACHMENT 4 (DQA RESULTS)
CENTRAL PENINSULA SURVEY UNIT 9530-0003 RELEASE RECORD ATTACHMENT 4A (PRELIMINARY DATA REVIEW)
PRELIMINARY DATA REVIEW FORM Survey Unit:
Survey Unit Name:
Classification :
9530-0003 Central Peninsula 2
Survey Media:
Soil Type of Survey : Final Status Survey Type of Measurement:
Radionuclide Specific n4umber of Measurements :
15 BASIC STATISTICAL QUANTITIES Cs-137 Target Level (pCi/g):
5.38E+00 Minimum Value:
5.70E-02 Maximum Value:
4.87E-01 Mean:
2.48E-01 Median :
2.83E-01 Standard Deviation :
1.18E-01 Sample Identification 9530-0003-001F 9530-0003-002F 9530-0003-003F 9530-0003-004F 9530-0003-005F 9530-0003-006F 9530-0003-007F 9530-0003-008F 9530-0003-009F 9530-0003-01OF 9530-0003-011IF 9530-0003-012F 9530-0003-013F 9530-0003-014F 9530-0003-015F Reported Results Cs-137 Concentration (pCi/g) 1.41E-01 3.26E-01 2.83E-01 3.09E-01 4.87E-01 9.57E-02 5.70E-02 2.89E-01 3.95E-01 2.87E-01 2.27E-01 3.19E-01 2.27E-01 1.17E-01 1.63E-01 Detect?
+
+
+
+
+
+
+
+
+
+
+
+
+
+
+
Fraction of Target Level 0.026 0.061 0.053 0.057 0.091 0.018 0.011 0.054 0.073 0.053 0.042 0.059 0.042 0.022 0.030 (5--ý Submitted by/Date
/l
- Ye 1 of 1
CENTRAL PENINSULA SURVEY UNIT 9530-0003 RELEASE RECORD ATTACHMENT 4B (GRAPHICAL REPRESENTATION OF DATA)
FREQUENCY PLOT FOR CESIUM-137 Survey Unit: 9530-0003 Survey Unit Name: Central Peninsula Mean: 2.48E-01 pCi/g Frequency Plot For Cs-137 10 8
S4-U--
2 0
5.70E-02 1.79E-01 3.01E-01 4.22E-01 5.44E-01 Upper End Value (pCi/g)
Upper End Observation Observation Value Frequency Frequency 5.70E-02 1
7%
1.79E-01 4
27%
3.01E-01 5
33%
4.22E-01 4
27%
5.44E-01 1
7%
Total:
15 100%
- m ek'
- 2. -/A)
Submitted by/Date J ReviewebyDt 1 of 1
QUANTILE PLOT FOR CESIUM-137 Survey Unit:
9530-0003 Survey Unit Name: Central Peninsula Mean:
2.48E-01 pCi/g Quantile Plot For Cs-137 6.OOE-01 5.00E-01
. 4.00E-01
-I 0
(" 3. 0 0 E -0 1 82.00E-01 C
1.00E-01 0.00E+00 0
20 40 60 80 100 Percentage Cs-137 Rank Percentage 5.70E-02 1
3%
9.57E-02 2
10%
1.17E-01 3
17%
1.41E-01 4
23%
1.63E-01 5
30%
2.27E-01 6
37%
2.27E-01 7
43%
2.83E-01 8
50%
2.87E-01 9
57%
2.89E-01 10 63%
3.09E-01 11 70%
3.19E-01 12 77%
3.26E-01 13 83%
3.95E-01 14 90%
4.87E-01 15 97% --)
."Oex- '0.feý 172--
Submitted by/Date-'
Review b/a
CENTRAL PENINSULA SURVEY UNIT 9530-0003 RELEASE RECORD ATTACHMENT 4C (SIGN TEST)
Connecticut Yankee Decommissioning Project Health Physics Procedure GPP-GGGR-R5121-001 Attachment A, Rev CY-001 MAJOR Sign Test Calculation Sheet For A Single Radionuclide or Gross Activity Measurements Survey Area Number: 9530 Survey Unit Number: 0003 Survey Area Name: Central Peninsula WPIR#: 2006-0038 Classification: 2 Type I (a error): 0.05 (N): 15 Radionuclide: Cs-137 DCGL: 5.38 Results (pCi/g)
DCGL - Results Sign 1.41E-01 5.24E+00 I
3.26E-01 5.05E+00 1
2.83E-01 5.1OE+00 I
3.09E-0I 5.07E+00 I
4.87E-01 4.89E+00 1
9.57E-02 5.28E+00 I
5.70E-02 5.32E+00 I
2.89E-01 5.09E+00 1
3.95E-01 4.99E+00 I
2.87E-01 5.09E+00 I
2.27E-01 5.15E+00 I
3.19E-0I 5.06E+00 1
2.27E-01 5.15E+00 1
1.17E-01 5.26E+00 I
1.63E-01 5.22E+00 I
Number of positive differences (S+): 15 Critical Value: 11 Performed by:
Survey Unit Meets Acceptance Criterion Date:
L)/2-
!/ý'6 Date:
,1 10(6 Independent Review b Page 1 of 1
CENTRAL PENINSULA SURVEY UNIT 9530-0003 RELEASE RECORD ATTACHMENT 4D (QC SPLIT RESULTS)
Health Physics Procedure 24265-000-GPP-GGGR-R5]24-000-Rev.CY-000 Attachment A HelhPyisPoeue246-0-P-GRR" 400-e.Y00Atcmn Split Sample Assessment Form Survey Area#: 9530 Survey Unit #: 0003 Survey Unit name: Central Peninsula Sample Plan or WPIR#: 2005-0038 SML#: 9530-0003-004 Sample
Description:
Comparison of split samples collected from sample measurement location #4 and analyzed using gamma spectroscopy by off-site Vendor Laboratory. The standard sample was 9530-0003-004F, the comparison sample was 9530-0003-004FS.
STANDARD COMPARISON Radionuclide Activity Standard Resolution Agreement Activity Standard Comparison Acceptable Value Error Range Value Error Ratio (Y1N)
Cs-137 3.09E-1I 3.06E-2 10 0.6-1.66 3.1IIE-l 3.63E-2 1.0 Y
Comments/Corrective Actions: N/O Table is provided to show acceptance criteria used to assess split samples.
Resolution 4-7 8 -15 16 - 50 51 -200
>200 Agreement Range 0.5-2.0 0.6 - 1.66 0.75 - 1.33 0.80 -1.25 0.85-1.18 Page 1 of 1
Health Physics Procedure 24265-000-GPP-GGGR-R5124-000-Rev.CY-000 Attachment A HelhPyisPoeue22500GPGG-5I2-0-e.Y00Atcmn Split Sample Assessment Form Survey Area#: 9530 Survey Unit #: 0003 Survey Unit name: Central Peninsula Sample Plan or WPIR#: 2005-0038 SML#: 9530-0003-006 Sample
Description:
Comparison of split samples collected from sample measurement location #6 and analyzed using gamma spectroscopy by off-site Vendor Laboratory. The standard sample was 9530-0003-006F, the comparison sample was 9530-0003-006FS.
STANDARD COMPARISON Radionuclide Activity Standard Resolution Agreement Activity Standard Comparison Acceptable Value Error Range Value Error Ratio (Y0N)
Cs-137 9.57E-2 1.64E-2 6
0.5-2.0 9.47E-2 1.43E-2 0.99 Y
I I
I
.1 1
1 1
1 I
1-
- 1-
-I-I t
I-Comments/Corrective Actions: N/A Table is provided to show acceptance criteria used to assess split samples.
Resolution 4-7 8 -15 16 -50 51 -200
>200 Agreement Range 0.5 -2.0 0.6 - 1.66 0.75 - 1.33 0.80 - 1.25 0.85 - 1.18 Page 1 of 1
CENTRAL PENINSULA SURVEY UNIT 9530-0003 RELEASE RECORD ATTACHMENT 4E (COMPASS DQA WITH POWER CURVE)
DQA Surface Soil Report Assessment Summary Site:
Planner(s):
Survey Unit Name:
Report Number:
Survey Unit Samples:
Reference Area Samples:
Test Performed:
Judgmental Samples:
Assessment
Conclusion:
9530-0003 FSS McCarthy m/b-/Lý/U Central Peninsula area 1
15 0
Sign Test Result:
Not Performed 0
EMC Result:
Not Performed Reject Null Hypothesis (Survey Unit PASSES)
Retrospective Power Curve U
.4-U I-5.
cI~
.5 LI' 1
0.9 0.7 0.6 0.5 0.4 0.3 0.2 0.1 0
1skd 0
1 2
3 4
5 Soil Concentration (p Ci/g), including 1ack*ound Prospective Power N
1-beta Actual Power LBGR Estimated Power DCGL Retrospective Power 6
COMPASS vI.0.0 11/2812006 Page I
DQA Surface Soil Report Survey Unit Data NOTE:
Type = "S" indicates survey unit sample.
Type = "R" indicates reference area sample.
Sample Number 9530-0003-001 F 9530-0003-002F 9530-0003-003F 9530-0003-004F 9530-0003-005F 9530-0003-006F 9530-0003-007F 9530-0003-008F 9530-0003-009F 9530-0003-01OF 9530-0003-011 F 9530-0003-012F 9530-0003-013F 9530-0003-014F 9530-0003-015F Type S
S S
S S
S S
S S
S S
S S
S S
Cs-137 (pCi/g) 0.14 0.33 0.28 0.31 0.49 0.1 0.06 0.29 0.4 0.29 0.23 0.32 0.23 0.12 0.16 Basic Statistical Quantities Summary Statistic Survey Unit Sample Number Mean (pCi/g)
Median (pCi/g)
Std Dev (pCi/g)
High Value (pCi/g)
Low Value (pCi/g)
15 Background
N/A N/A DQO Results N=15 0.26 0.25 0.28 0.12 0.49 0.06 N/A N/A N/A N/A N/A 0.0713 N/A N/A COMPASS v1.0.0 11/28/2006 Page 2